38YZA Puron® Heat Pump

024-060, Series 1
208/230-1-60
Visit www.carrier.com

Wiring Diagrams
CONNECTION DIAGRAM EQUIP SCHEMATIC DIAGRAM
BLK GND (LADDER FORM)
BLK BLK L1 *DSV
BLU L2
* DSV
*CHS BLU COMP
*CH COMP
BLU +t CONT R
BLK BLK BLK S YEL C CONT
C *ST
L1 BLK 11 21
S
208/230 1 11 21 R YEL 23 23
POWER L2 YEL
BRN 5 2 *SC +t
SUPPLY 23 23 YEL *SC H
CAP *CHS 1
EQUIP OFM *CH
GND CONT BRN 1 2 *SR *ST
C
BLK 5
YEL OFM
VPS *SR DR F
BLK YEL CAP
BRN VPS OF1 OF2
*LPS DTS *HPS
BLK YEL / PNK RED RED BLU / PNK RVS C
YEL / PNK

BLU / PNK
O O RVSR

W2
Y DFT
R R AUXR DFT
T1 LOGIC
LOGIC RVSR
DR CTD T2 YEL
OF1
C
BRN Y Y AUXR

LOGIC C ORG
CTD
RVS T1 T2 C
OF2 O
ORG ORG ORG
60
or or
SPEED

120 90 *LPS DTS *HPS CONT


UP

BLK BLK LOGIC


30 DFT C
PNK
C Y O W2 R R PNK
CB CESO130076-01 BLK BLK
or or
YEL WHT PNK PNK
BLK ORN RED DFT NOTE
THIS DEFROST CONTROL BOARD CONTAINS A FIVE MINUTE SHORT CYCLE
C Y O W2 R E L W3 G INDOOR UNIT PROTECTOR. A FIVE MINUTE DELAY WILL OCCUR BETWEEN COMPRESSOR
TERMINAL BLOCK OFF/ON CYCLES.

C Y O W2 R E L G INDOOR THERMOSTAT (NOTE #5) -LEGEND-


FACTORY POWER WIRING
NOTES: FIELD POWER WIRING
FACTORY CONTROL WIRING
1. COMPRESSOR AND FAN MOTOR FURNISHED WITH INHERENT THERMAL PROTECTION. FIELD CONTROL WIRING
2. TO BE WIRED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE (N.E.C.) AND LOCAL CODES. CONDUCTOR ON CIRCUIT BOARD
3. N.E.C. CLASS 2, 24 V CIRCUIT, MIN. 40 VA REQUIRED, 60VA ON UNITS INSTALLED WITH LLS.
4. USE COPPER CONDUCTORS ONLY FROM DISCONNECT TO UNIT. COMPONENT CONNECTION
5. MUST USE THERMOSTAT AND SUB-BASE AS STATED IN PRE-SALE LITERATURE. 1/4-INCH QUICK CONNECT
6. IF INDOOR SECTION HAS A TRANSFORMER WITH A GROUNDED SECONDARY, CONNECT THE GROUNDED TERMINALS
SIDE TO "C" ON THE CIRCUIT BOARD. FIELD SPLICE
7. IF ANY OF THE ORIGINAL WIRE, AS SUPPLIED, MUST BE REPLACED, USE THE SAME OR EQUIVALENT WIRE.
JUNCTION
8. CHECK ALL ELECTRICAL CONNECTIONS INSIDE CONTROL BOX FOR TIGHTNESS.
9. DO NOT ATTEMPT TO OPERATE UNIT UNTIL SERVICE VALVES HAVE BEEN OPENED. AUXR AUXILLARY HEAT RELAY
10. USE CONDUCTORS SUITABLE FOR AT LEAST 75 C (167 F). CAP CAPACITOR (DUAL RUN)
*CH CRANKCASE HEATER
*CHS CRANKCASE HEATER SWITCH
DIP SWITCH SETTINGS COMP COMPRESSOR
(DEFAULT) 120 MINUTES
30 MINUTES 60 MINUTES 90 MINUTES 120 ON CTD COMPRESSOR TIME DELAY
CONT CONTACTOR
30 1 2 3 1 2 3 60 1 2 3 1 2 3 1 2 3 CB CIRCUIT BOARD
DFT DEFROST THERMOSTAT
OR OR OR QUIET DR DEFROST RELAY AND CIRCUITRY
SHIFT DTS DISCHARGE TEMPERATURE SWITCH
*DSV DISCH. SOLENOID VALVE (WHEN USED)
90 OFF *HPS HIGH PRESSURE SWITCH
(DEFAULT *LPS LOW PRESSURE SWITCH
OFM OUTDOOR FAN MOTOR
RVS REVERSING VALVE SOLENOID
FIELD SELECTABLE OPTIONS FOR TIME PERIOD RVSR REVERSING VALVE SOLENOID RELAY
BETWEEN DEFROST CYCLES (MINUTES) *SC START CAPACITOR
*SR START RELAY
SPEED JUMPERED TEST PINS (USE METAL OBJECT), FIELD SPEED-UP CYCLE *ST START THERMISTOR
UP VPS VAPOR PRESSURE SWITCH
1) MOMENTARILY SHORT PINS AND RELEASE TO BYPASS COMPRESSOR OFF DELAY.
* MAY BE FACTORY OR FIELD INSTALLED
2) SHORT FOR 5+ SEC. AND RELEASE FOR FORCED DEFROST.
3) PERMANENT SHORT WILL BE IGNORED.
DEFROST WILL TERMINATE IN 30 SEC. IF DFT OPEN.
DEFROST WILL TERMINATE NORMALLY IF DFT IS CLOSED. 325779-101 REV. B

A00004
Fig. 1—38YZA024-048 (1); 208/230v; 1 Phase; 60 Hertz

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1 4 PC 101 Catalog No. 533-753 Printed in U.S.A. Form 38YZA-2W Pg 1 3-00 Replaces: 38YZA-1W
Tab 5a 5a
CONNECTION DIAGRAM EQUIP SCHEMATIC DIAGRAM
BLK BLK GND
*DSV
(LADDER FORM)
L1
*DSV
*CHS BLK COMP
*CH
COMP BLU BLU CONT R
BLK BLK BLK S CAP C L2
C
L1 BLK 11 21
208/230 1 S
L2 11 21 YEL R YEL
POWER BRN 5 2 *SC
SUPPLY 13 23 YEL *SC H
*CH 1 CONT
EQUIP OFM BRN
GND CONT 1 2 *SR
*CHS C
BLK 5 23 13
VPS OFM F
*SR VPS DR
YEL
BLK YEL CAP
BRN OF1 OF2
*LPS DTS *HPS
BLK YEL / PNK RED RED BLU / PNK
RVS C
YEL / PNK

BLU / PNK
O O RVSR

Y W2
DFT
T1
R R AUXR DFT
LOGIC
LOGIC
DR CTD T2 YEL RVSR
OF1
C
BRN
Y Y AUXR
LOGIC C ORG

OF2 O RVS CTD


ORG ORG ORG T1 T2 C
60
or or
SPEED

120 90
UP

BLK BLK *LPS DTS CONT


30 DFT *HPS LOGIC
PNK C
C Y O W2 R R PNK
CB CESO130076-01 BLK BLK
or or
YEL WHT PNK PNK
BLK ORN RED DFT NOTE
THIS DEFROST CONTROL BOARD CONTAINS A FIVE MINUTE SHORT CYCLE
C Y O W2 R E L W3 G INDOOR UNIT PROTECTOR. A FIVE MINUTE DELAY WILL OCCUR BETWEEN COMPRESSOR
TERMINAL BLOCK OFF/ON CYCLES.

C Y O W2 R E L G INDOOR THERMOSTAT (NOTE #5) -LEGEND-


FACTORY POWER WIRING
NOTES:
1. COMPRESSOR AND FAN MOTOR FURNISHED WITH INHERENT THERMAL PROTECTION. FIELD POWER WIRING
2. TO BE WIRED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE (N.E.C.) AND LOCAL CODES. FACTORY CONTROL WIRING
3. N.E.C. CLASS 2, 24 V CIRCUIT, MIN. 40 VA REQUIRED, 60VA ON UNITS INSTALLED WITH LLS. FIELD CONTROL WIRING
4. USE COPPER CONDUCTORS ONLY FROM DISCONNECT TO UNIT. CONDUCTOR ON CIRCUIT BOARD
5. MUST USE THERMOSTAT AND SUB-BASE AS STATED IN PRE-SALE LITERATURE.
COMPONENT CONNECTION
6. IF INDOOR SECTION HAS A TRANSFORMER WITH A GROUNDED SECONDARY, CONNECT THE
GROUNDED SIDE TO "C" ON THE CIRCUIT BOARD. 1/4-INCH QUICK CONNECT
7. IF ANY OF THE ORIGINAL WIRE, AS SUPPLIED, MUST BE REPLACED, USE THE SAME OR TERMINALS
EQUIVALENT WIRE. FIELD SPLICE
8. CHECK ALL ELECTRICAL CONNECTIONS INSIDE CONTROL BOX FOR TIGHTNESS. JUNCTION
9. DO NOT ATTEMPT TO OPERATE UNIT UNTIL SERVICE VALVES HAVE BEEN OPENED.
AUXR AUXILLARY HEAT RELAY
10. USE CONDUCTORS SUITABLE FOR AT LEAST 75 C (167 F).
CAP CAPACITOR (DUAL RUN)
*CH CRANKCASE HEATER
DIP SWITCH SETTINGS *CHS CRANKCASE HEATER SWITCH
(DEFAULT) 120 MINUTES COMP COMPRESSOR
30 MINUTES 60 MINUTES 90 MINUTES 120 ON
CTD COMPRESSOR TIME DELAY
30 1 2 3 1 2 3 60 1 2 3 1 2 3 1 2 3 CONT CONTACTOR
CB CIRCUIT BOARD
OR OR OR QUIET DFT DEFROST THERMOSTAT
SHIFT DR DEFROST RELAY AND CIRCUITRY
DTS DISCHARGE TEMPERATURE SWITCH
90 OFF *DSV DISCH. SOLENOID VALVE (WHEN USED)
(DEFAULT *HPS HIGH PRESSURE SWITCH
*LPS LOW PRESSURE SWITCH
OFM OUTDOOR FAN MOTOR
FIELD SELECTABLE OPTIONS FOR TIME PERIOD
RVS REVERSING VALVE SOLENOID
BETWEEN DEFROST CYCLES (MINUTES)
RVSR REVERSING VALVE SOLENOID RELAY
*SC START CAPACITOR
SPEED JUMPERED TEST PINS (USE METAL OBJECT), FIELD SPEED-UP CYCLE *SR START RELAY
UP VPS VAPOR PRESSURE SWITCH
1) MOMENTARILY SHORT PINS AND RELEASE TO BYPASS COMPRESSOR OFF DELAY.
2) SHORT FOR 5+ SEC. AND RELEASE FOR FORCED DEFROST. * MAY BE FACTORY OR FIELD INSTALLED
3) PERMANENT SHORT WILL BE IGNORED.
DEFROST WILL TERMINATE IN 30 SEC. IF DFT OPEN.
DEFROST WILL TERMINATE NORMALLY IF DFT IS CLOSED.
325778-101 REV. B

A00003
Fig. 2—38YZA060 (1); 208/230v; 1 Phase; 60 Hertz

Copyright 2000 CARRIER Corp. • 7310 W. Morris St. • Indianapolis, IN 46231 38yza2w

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1 4 PC 101 Catalog No. 533-753 Printed in U.S.A. Form 38YZA-2W Pg 2 3-00 Replaces: 38YZA-1W