0% found this document useful (0 votes)
91 views11 pages

SDV10

The document discusses vane pumps including models SDV10, SDV20, SDV2010, and SDV2020. It provides technical specifications for each model such as ordering codes, operating characteristics, dimensions, and pressure and speed ratings. General instructions are also provided on applications, maximum speeds, pressure ratings, and characteristics.

Uploaded by

Luis Josue
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
91 views11 pages

SDV10

The document discusses vane pumps including models SDV10, SDV20, SDV2010, and SDV2020. It provides technical specifications for each model such as ordering codes, operating characteristics, dimensions, and pressure and speed ratings. General instructions are also provided on applications, maximum speeds, pressure ratings, and characteristics.

Uploaded by

Luis Josue
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 11

Vane pumps

single and double


SDV10 - SDV20 - SDV2010 - SDV2020

Publ. 1 - EN0738 - A 06 / 2001 / FB Replaces : L13 - 10738 - 1

Back To The Table Of Content


CONTENTS

GENERAL General applications instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2


Maximum speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Pressure ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Minimum allowable inlet pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
General characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

SD V10 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4


Operating characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

SD V20 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6


Operating characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

SD V2010 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8


Operating characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

SD V2020 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10


Operating characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

GENERAL APPLICATIONS 1. Check speed range, pressure, temperature, fluid quality, viscosity and pump rotation.
INSTRUCTIONS
2. Check inlet conditions of the pump, if it can accept application requirement.
3. Type of shaft : if would support operating torque.
4. Coupling must be chosen to minimize pump shaft load (weight, misalignment).
5. Filtration : must be adequate for lowest contamination level.
6. Environment of pump : avoid noise reflection, pollution and shocks.

Parker Hannifin
2 Back To The Table Of Content Denison Vane Pump Division
Vierzon - France
TECHNICAL DATA

MINIMUM AND MAXIMUM SPEED, PRESSURE RATINGS


Theoretical Maximum speed Maximum pressure
Series Size Displacement HF-0, HF-1 HF-3, HF-4 HF-0, HF-2 HF-1, HF-4, HF-5 HF-3
Vi HF-2 HF-5 Int. Cont. Cont Cont.
cm3/rev (in3/rev) RPM RPM Bar (psi) Bar (psi) Bar (psi) Bar (psi)
1 3,3 (.20) 4200 1800 175 (2500) 160 (2250) 130 (1900) 100 (1500)
2 6,6 (.40) 4200 1800 175 (2500) 160 (2250) 130 (1900) 100 (1500)
3 9,8 (.60) 3900 1800 175 (2500) 160 (2250) 130 (1900) 100 (1500)
SDV10 4 13,1 (.80) 3000 1800 175 (2500) 160 (2250) 130 (1900) 100 (1500)
5 16,4 (1.00) 2400 1800 175 (2500) 160 (2250) 130 (1900) 100 (1500)
6 19,5 (1.19) 2100 1800 150 (2200) 140 (2000) 130 (1900) 100 (1500)
7 22,8 (1.39) 1800 1800 140 (2000) 140 (2000) 130 (1900) 100 (1500)
6 19,5 (1.19) 3600 1800 175 (2500) 160 (2250) 130 (1900) 110 (1600)
7 22,8 (1.39) 2700 1800 175 (2500) 160 (2250) 130 (1900) 110 (1600)
8 26,5 (1.62) 2400 1800 175 (2500 160 (2250) 130 (1900) 110 (1600)
SDV20 9 29,7 (1.81) 2100 1800 175 (2500) 160 (2250) 130 (1900) 110 (1600)
11 36,4 (2.22) 1800 1800 175 (2500) 160 (2250) 110 (1600) 100 (1400)
12 39,0 (2.38) 1800 1800 150 (2200) 140 (2000) 110 (1600) 100 (1400)
13 42,4 (2.59) 1800 1800 150 (2200) 140 (2000) 110 (1600) 100 (1400)
HF-0, HF-2 = Anti-wear petroleum base. HF-1 = Non anti-wear petroleum base. HF-5 = Synthetic fluids.
HF-3 = Water-in-oil invert emulsions. HF-4 = Water glycol solutions.
For further information, if the performance characteristics outlined above do not meet your own particular requirements, please consult your local
DENISON Hydraulics office.

MINIMUM ALLOWABLE INLET PRESSURE (BAR ABSOLUTE / PSI)


Speed RPM
Series Size Size
1500 1800 2100 2400 2700 3000 3300 3600 3900 4200
0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80
1 1
(11.6) (11.6) (11.6) (11.6) (11.6) (11.6) (11.6) (11.6) (11.6) (11.6)
0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80
2 2
(11.6) (11.6) (11.6) (11.6) (11.6) (11.6) (11.6) (11.6) (11.6) (11.6)
0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,85 0,95
3 3
(11.6) (11.6) (11.6) (11.6) (11.6) (11.6) (11.6) (12.3) (13.8)
0,80 0,80 0,80 0,80 0,85 0,95
4 4
(11.6) (11.6) (11.6) (11.6) (12.3) (13.8)
SDV10 0,80 0,80 0,85 0,95
5 5
(11.6) (11.6) (12.3) (13.8)
0,80 0,85 1,00
6 6
(11.6) (12.3) (14.5)
0,85 1,00
7 7
(12.3) (14.5)
0,80 0,80 0,80 0,80 0,80 0,85 0,95 1,01
6 6
(11.6) (11.6) (11.6) (11.6) (11.6) (12.3) (13.8) (14.6)
0,80 0,80 0,80 0,80 0,80
7 7
(11.6) (11.6) (11.6) (11.6) (11.6)
0,80 0,80 0,85 0,95
8 8
(11.6) (11.6) (12.3) (13.8)
0,80 0,80 0,95
9 9
(11.6) (11.6) (13.8)
SDV20 0,80 0,95
11 11
(11.6) (13.8)
0,85 1,03
12 12
(12.3) (14.9)
0,95 1,05
13 13
(13.8) (15.2)
Multiply absolute pressure by 1,25 for HF-3, HF-4 fluids.
by 1,35 for HF-5 fluids.
by 1,10 for ester or rapeseed base.
Use the cartridge with the highest absolute pressure for double pumps.
GENERAL CHARACTERISTICS
Moment of
Mounting Weight inertia Port connections
Series
standard kg (lb) kgm2 x 10-4
(lb.in2) Suction Pressure
Code P S B P S B
SDV10 SAE A 4,5 – 6,8 (10 – 15) 0,5 (0.17) 1” NPTF 1”5/16 12UNF-2B G 1” 1/2” NPTF 3/4” 16UNF-2B G 1/2”
SDV20 SAE A 7,3 – 8,2 (16 – 18) 2,2 (0.75) 1”1/4 NPTF 1”5/8 12UNF-2B G 1”1/4 3/4” NPTF 1”1/16 12UNF-2B G 3/4”
Code F S B
P1* P2** P1-P2
SDV2010 SAE B 13,6 ( 30.0) 2,6 (0.90) 4 bolts flange 1”1/2 dia 1”1/16 12UNF-2B 3/4” 16UNF-2B ***
SDV2020 SAE B 15,9 (35.0) 4,3 (1.50) 4 bolts flange 2” dia 1”1/16 12UNF-2B 1”1/16 12UNF-2B G 3/4”

* P1 = Pressure port near the shaft ** P2 = Pressure port near the cover end *** P1 = G 3/4” P2 = G 1/2”

Parker Hannifin
3 Back To The Table Of Content Denison Vane Pump Division
Vierzon - France
ORDERING CODE - SDV10 SERIES

Model No. SDV 10 - 1 P 5 S - 1 C L

Vane pump Shaft rotation (view on shaft end)


L = Counter-clockwise
Series Omit for clockwise
10
Position of outlet port (Viewed from
Mounting cover end of pump)
1 = 2-bolt flange, 3”1/4 pilot (SAE A) (standard) A = Opposite inlet port
Inlet port connections B = 90° CCW from inlet
P = 1” NPTF thread C = In line with inlet
S = 1”5/16-12 UNF-2B thread D = 90° CW from inlet
B = G 1” (BSPP) Shaft
Ring size 1 = Straight keyed
(Delivery at 1200 rpm and 100 psi) 11 = Splined
1 = 1 USgpm 38 = 11 teeth - 3/4” OD
2 = 2 USgpm Outlet port connections
3 = 3 USgpm P = 1/2” NPTF thread
4 = 4 USgpm S = 3/4”-16 UNF-2B thread
5 = 5 USgpm B = G 1/2” (BSPP)
6 = 6 USgpm
7 = 7 USgpm

OPERATING CHARACTERISTICS
Displ. Max. Typical delivery Typical input power
Model Ring Speed
cm3/rev Pressure L/min (Usgpm) KW (hp)
Series Size RPM
(in3/rev) bar (psi) 0 bar 0 PSI 150 bar 2000 PSI 7 bar 80 PSI 175 bar 2500 PSI
1200 4,0 1,0 2,0 0,5 0,07 0,09 0,71 0,96
1 3,3 (.20) 175 (2500) 1500 5,0 1,3 3,0 0,8 0,09 0,12 1,08 1,44
1800 5,9 1,6 3,9 1,0 0,10 0,14 1,44 1,93
1200 7,9 2,1 5,9 1,6 0,14 0,18 2,16 2,89
2 6,6 (.40) 175 (2500) 1500 9,9 2,6 7,9 2,1 0,17 0,23 2,88 3,86
1800 11,9 3,1 9,9 2,6 0,21 0,28 3,60 4,83
1200 11,8 3,1 9,8 2,6 0,20 0,27 3,56 4,77
3 9,8 (.60) 175 (2500) 1500 14,7 3,9 12,7 3,4 0,26 0,34 4,63 6,21
1800 17,6 4,7 15,6 4,1 0,31 0,41 5,70 7,65
1200 15,7 4,2 12,3 3,3 0,27 0,37 4,49 6,02
SDV10 4 13,1 (.80) 175 (2500) 1500 19,7 5,2 16,3 4,3 0,34 0,46 5,92 7,94
1800 23,6 6,2 20,2 5,3 0,41 0,55 7,36 9,87
1200 19,7 5,2 16,3 4,3 0,34 0,46 5,94 7,96
5 16,4 (1.00) 175 (2500) 1500 24,6 6,5 21,2 5,6 0,43 0,57 7,73 10,36
1800 29,5 7,8 26,1 6,9 0,51 0,69 9,52 12,77
1200 23,4 6,2 19,2 5,1 0,41 0,55 7,00 9,39
6 19,5 (1.19) 152 (2200) 1500 29,3 7,7 25,1 6,6 0,51 0,68 9,13 12,25
1800 35,1 9,3 30,9 8,2 0,61 0,82 11,27 15,11
1200 27,4 7,2 23,2 6,1 0,48 0,64 8,44 11,32
7 22,8 (1.39) 138 (2000) 1500 34,2 9,0 30,0 7,9 0,60 0,80 10,94 14,67
1800 41,0 10,8 36,8 9,7 0,71 0,96 13,43 18,01

INTERNAL LEAKAGE (TYPICAL) NOISE LEVEL (TYPICAL)


SDV10 - 6
Lp. Noise level [db(A)] 1 m ISO 4412

3
.75

70
Internal leakage qVs l/min [GPM]

6 & 7 rings 1200 RPM


1500 RPM
4 & 5 rings 1800 RPM
1, 2 & 3 rings
.50

2 65

1
.25

60

0
0

55
0 35 70 105 140 175 0 40 80 120 160 200

0 500 1000 1500 2000 2500 0 580 1160 1740 2300 2900

Pressure p bar [PSI] Pressure p bar [PSI]


Do not operate pump more than 5 seconds at any speed or vis-
cosity if internal leakage is higher than 50% of theoretical flow.
Total leakage is the sum of each section loss at its operating
conditions.

Parker Hannifin
4 Back To The Table Of Content Denison Vane Pump Division
Vierzon - France
DIMENSIONS - Weight : 4,5 - 6,8 Kg (10 - 15 lb) - SDV10 SERIES

Inlet port
1"5/16 - 12 UNF - 2B thd. (shown) 12,70

(DIA. 3.250/3.248)
or 1" NPTF thd. (.50)

(DIA. .750/.749)
or G 1"

82,55
82,50
19,05
19,02
7,9

(DIA. .843)
Ø 21,40
(.31)

Ø
Ø
Ø 46
(DIA. 1.81)

Outlet port
3/4" - 16 UNF - 2B thd. (shown)
or 1/2" NPTF thd.
or G 1/2" 24,60

21,13/21,00
(.832/.827)
(.97)
76,20
(3.00) B 44,40
Clockwise
A (1.75) rotation
38,10 Sq 4,75 (.187) key
(1.50) 25,4 (1.00) long

(DIA. 1.35)
Ø 34,3
SAE "A"

(DIA. 1.57)
Ø 40,0
flange
(2.47)
62,70
38,10
(1.50)

Number 1 Shaft
2,2
(.087) 53,15 Ø 95,2
6,35 / 6,10 (2.09) (DIA. 3.75)
(.250/.240)
106,30
Ø 11.1(DIA. .437) (4.19)
2 holes
Ø 130,00
(DIA. 5.12)

Number 11 shaft Number 38 shaft


31,80
(1.25)

14,70 31,8
(.58) (1.25)
Involute spline Involute spline
Flat root - Major dia. fit 16/32 diametral pitch
16/32 diametral pitch Flat root
9 teeth - 14,29 (.5625) pitch dia. 11 teeth - 30˚ pressure angle
30˚ pressure angle Minor dia. - 14,98 (.590)
Major dia. - 15,82/15,80 (.623/.622)
Minor dia. - 12,28/12,00 (.4835/.4725)

20,6
(DIA. .748/.745)

(.811)
(DIA. .598)
Ø 15,2

19,01
18,93

7,90
Ø

(.31)

Ring Dimensions Weight


size A B Kg (lb)

1 115,6 (4.55) 91,9 (3.62) 4,5 - (10.0)


2 115,6 (4.55) 91,9 (3.62) 4,5 - (10.0)
3 115,6 (4.55) 91,9 (3.62) 4,5 - (10.0)
4 121,9 (4.80) 98,3 (3.87) 5,6 - (12.5)
5 121,9 (4.80) 98,3 (3.87) 5,6 - (12.5)
6 127,0 (5.00) 103,4 (4.07) 6,8 - (15.0)
7 127,0 (5.00) 103,4 (4.07) 6,8 - (15.0)

Parker Hannifin
5 Back To The Table Of Content Denison Vane Pump Division
Vierzon - France
ORDERING CODE - SDV20 SERIES

Model No. SDV 20 - 1 P 8 S - 1 C L

Vane pump Shaft rotation (view on shaft end)


L = Counter-clockwise
Series Omit for clockwise
20
Position of outlet port (Viewed from
Mounting cover end of pump)
1 = 2-bolt flange, 3”1/4 pilot (standard) A = Opposite inlet port
Inlet port connections B = 90° CCW from inlet
P = 1”1/4 NPTF thread C = In line with inlet
S = 1”5/8 - 12 UNF-2B thread D = 90° CW from inlet
B = G 1”1/4 (BSPP) Shaft
Ring size 1 = Straight keyed
(Delivery at 1200 rpm and 100 psi) 11 = Splined
6 = 6 USgpm 38 = 11 teeth - 3/4” OD
7 = 7 USgpm 62 = Splined
8 = 8 USgpm Outlet port connections
9 = 9 USgpm P = 3/4” NPTF thread
11 = 11 USgpm S = 1”1/16 - 12 UNF-2B thread
12 = 12 USgpm B = G 3/4” (BSPP)
13 = 13 USgpm

OPERATING CHARACTERISTICS
Displ. Max. Typical delivery Typical input power
Model Ring Speed
cm3/rev Pressure L/min (Usgpm) KW (hp)
Series Size
(in3/rev) bar (psi)
RPM
0 bar 0 PSI 150 bar 2000 PSI 7 bar 80 PSI 175 bar 2500 PSI
1200 23,40 6,18 19,80 5,23 0,4 0,5 6,8 9,1
6 19,5 (1.19) 175 (2500) 1500 29,25 7,73 25,65 6,78 0,5 0,6 8,8 11,8
1800 35,10 9,27 31,50 8,32 0,5 0,7 10,8 14,5
1200 27,36 7,23 21,96 5,80 0,4 0,6 7,5 10,1
7 22,8 (1.39) 175 (2500) 1500 34,20 9,04 28,80 7,61 0,5 0,7 9,9 13,3
1800 41,04 10,84 35,64 9,42 0,6 0,9 12,2 16,4
1200 31,80 8,40 26,40 6,97 0,5 0,7 9,1 12,1
8 26,5 (1.62) 175 (2500) 1500 39,75 10,50 34,35 9,08 0,6 0,8 11,8 15,8
1800 47,70 12,60 42,30 11,18 0,7 1,0 14,5 19,5
1200 35,64 9,42 30,24 7,99 0,6 0,7 10,4 13,9
SDV20 9 29,7 (1.81) 175 (2500) 1500 44,55 11,77 39,15 10,34 0,7 0,9 13,4 18,0
1800 53,46 14,12 48,06 12,70 0,8 1,1 16,5 22,1
1200 43,68 11,54 40,28 10,64 0,7 0,9 13,8 18,5
11 36,4 (2.22) 175 (2500) 1500 54,60 14,43 51,20 13,53 0,8 1,1 17,6 23,6
1800 65,52 17,31 62,12 16,41 1,0 1,4 21,3 28,6
1200 46,80 12,36 42,60 11,25 0,7 1,0 14,6 19,6
12 39,0 (2.38) 152 (2200) 1500 58,50 15,46 54,30 14,35 0,9 1,2 18,6 25,0
1800 70,20 18,55 66,00 17,44 1,1 1,5 22,6 30,4
1200 50,88 13,44 46,68 12,33 0,8 1,1 16,0 21,5
13 42,4 (2.59) 152 (2200) 1500 63,60 16,80 59,40 15,69 1,0 1,3 20,4 27,3
1800 76,32 20,16 72,12 19,05 1,2 1,6 24,7 33,2

INTERNAL LEAKAGE (TYPICAL) NOISE LEVEL (TYPICAL)


SDV20 - 13
6
1.5

75
Lp. Noise level [db(A)] 1 m ISO 4412
Internal leakage qVs l/min [GPM]

7,8 & 9 rings 1200 RPM


12 & 13 rings 1500 RPM
1.25

5
6 ring 1800 RPM
11 ring 70

4
1.0

3
.75

65
.50

2
60
.25

0 55
0

0 40 80 120 160 200


0 35 70 105 140 0 580 1160 1740 2300 2900
0 500 1000 1500 2000
Pressure p bar [PSI] Pressure p bar [PSI]
Do not operate pump more than 5 seconds at any speed or vis-
cosity if internal leakage is higher than 50% of theoretical flow.
Total leakage is the sum of each section loss at its operating
conditions.

Parker Hannifin
6 Back To The Table Of Content Denison Vane Pump Division
Vierzon - France
DIMENSIONS - Weight : 7,3 - 8,2 Kg (16 - 18 lb) - SDV20 SERIES

Outlet port
1"1/16 - 12 UNF - 2B thread
SAE O-ring boss connection or
3/4" NPTF thd
or G 3/4"

Number 1 Shaft

(DIA. .832/.827)
82,55
82,50
Ø
Inlet port
1"1/4 NPTF or
1"5/8 - 12 UNF - 2B thd.
12,70
SAE O-ring boss connection
(.50) or G 1"1/4
31,0 Clockwise
(1.22) rotation
B

A 67,60 106,30
(2.66) (4.187)

4,00 53,15
(.156) (2.093)
55,60 55,60
(2.19) (2.19) 3,2
(.126)

(DIA. 1.85)
SAE "A"

Ø 47,0
Sq 4,76 (.1875) key
flange
(2.44)

41,1 (1.62) long


(2.60)
66,00

62
(2.19)
55,60

Ø 19,05 / 19,02
(DIA. .750/.749)
21,10 / 21,00
(DIA. 1.161)

(DIA. 1.612)

(.832/.827)
Ø 40,95

2,0
Ø 29,5

(.08) Ø 95.2
(DIA. 3.75)
3,8
(.148)
Ø 130,0
4,4 (DIA. 5.12)
Ø 11.1 (DIA. .437)
(.173)
2 holes

Number 11 shaft Number 62 shaft Number 38 shaft


74,80
(2.94) 31,80 31,8
(1.25) (1.25)
50,80 Involute spline
(2.00) 37,30 full depth of spline 14,70 16/32 diametral pitch
(1.47) (.58) Flat root
11 teeth - 30˚ pressure angle
Minor dia. - 14,98 (.590)
Involute spline
Involute spline Flat root - Major dia. fit
16/32 diametral pitch 16/32 diametral pitch
Flat root - 11 teeth 9 teeth - 14,29 (.5625) pitch dia.
30˚ pressure angle 30˚ pressure angle
Major dia. - 15,82/15,80 (.632/.622)
Minor dia. - 12,28/12,00 (.4835/.4725)

20,6
(.811)
(DIA. .748/.745)
(DIA. .748/.745)

19,01
18,93
(DIA. .751/.749)
19,07
19,02

19,01
18,93

7,9
Ø

(.31)

Ring Dimensions Weight


size A B Kg (lb)

6 125,2 (4.93) 102,1 (4.02) 7,3 - (16.0)


7 131,6 (5.18) 108,4 (4.27) 7,7 - (17.0)
8 131,6 (5.18) 108,4 (4.27) 7,7 - (17.0)
9 131,6 (5.18) 108,4 (4.27) 7,7 - (17.0)
11 136,6 (5.38) 113,5 (4.47) 8,0 - (17.5)
12 140,2 (5.52) 117,1 (4.61) 8,2 - (18,0)
13 140,2 (5.52) 117,1 (4.61) 8,2 - (18.0)

Parker Hannifin
7 Back To The Table Of Content Denison Vane Pump Division
Vierzon - France
ORDERING CODE - SDV2010 SERIES

Model No. SDV 2010 - 1 F 13 S 3 S - 1 CC - L

Vane pump Shaft rotation (view on shaft end)


L = Left hand for counter-clockwise
Series Omit for right hand
2010
Position of outlet port (Viewed from
Mounting cover end of pump)
1 = 2-bolt flange, 4” pilot (standard) With n°1 outlet opposite inlet
Inlet port connections AA = N° 2 outlet 135° CCW from inlet
F = 4 bolt flange 1”1/2 dia AB = N° 2 outlet 45° CCW from inlet
AC = N° 2 outlet 45° CW from inlet
Shaft-end pump ring size AD = N° 2 outlet 135° CW from inlet
(Delivery at 1200 rpm and 100 psi) With n°1 outlet 90° CCW from inlet
6 = 6 USgpm BA = N° 2 outlet 135° CCW from inlet
7 = 7 USgpm BB = N° 2 outlet 45° CCW from inlet
8 = 8 USgpm BC = N° 2 outlet 45° CW from inlet
9 = 9 USgpm BD = N° 2 outlet 135° CW from inlet
11 = 11 USgpm With n°1 outlet in line with inlet
12 = 12 USgpm CA = N° 2 outlet 135° CCW from inlet
13 = 13 USgpm CB = N° 2 outlet 45° CCW from inlet
No 1 outlet port (shaft end) CC = N° 2 outlet 45° CW from inlet
S = 1”1/16 - 12 UNF-2B thd CD = N° 2 outlet 135° CW from inlet
B = G 3/4” (BSPP) With n°1 outlet 90° CW from inlet
DA = N° 2 outlet 135° CCW from inlet
Cover-end pump ring size DB = N° 2 outlet 45° CCW from inlet
(Delivery at 1200 rpm and 100 psi DC = N° 2 outlet 45° CW from inlet
1 = 1 USgpm DD = N° 2 outlet 135° CW from inlet
2 = 2 USgpm
3 = 3 USgpm Shaft
4 = 4 USgpm 1 = Straight keyed
5 = 5 USgpm 11 = Splined
6 = 6 USgpm N° 2 outlet port (cover end)
7 = 7 USgpm S = 3/4”-16 UNF-2B thread
B = G 1/2” (BSPP)

OPERATING CHARACTERISTICS
Displ. Max.
Model Ring
cm3/rev Pressure
Series Size
(in3/rev) bar (psi)
6 19,5 (1.19) 175 (2500)
7 22,8 (1.39) 175 (2500)
8 26,5 (1.62) 175 (2500)
P1 9 29,7 (1.81) 175 (2500) Please refer to page 6
11 36,4 (2.22) 175 (2500)
12 39,0 (2.38) 152 (2200)
13 42,4 (2.59) 152 (2200)
1 3,3 (.20) 175 (2500)
2 6,6 (.40) 175 (2500)
3 9,8 (.60) 175 (2500)
P2 4 13,1 (.80) 175 (2500) Please refer to page 4
5 16,4 (1.00) 175 (2500)
6 19,5 (1.19) 152 (2200)
7 22,8 (1.39) 138 (2000)

Parker Hannifin
8 Back To The Table Of Content Denison Vane Pump Division
Vierzon - France
DIMENSIONS - Weight : 13,6 Kg (30 lb) - SDV2010 SERIES

1/2"-13 UNC-2B THD.


22,35 (.88) DEEP 4 HOLES Number 1 shaft extension Number 11 shaft
35,71 12,70
(1.406) (.50) 41,1
7,8 (.31) (1.62)
17,85 9,40

(DIA. .703)

(DIA. 1.50)
(.703) (.37)

Ø 29,20
Ø 17,90
(2.750)
69,85

34,925
(1.375)
Involute spline
Major diameter fit
N˚ 1 OUTLET PORT 16/32 diametral pitch
1"1/16 - 12 UNF - 2B THD 13 teeth
INLET PORT or G 3/4"
30˚ pressure angle
Ø 38,1 (DIA. 1.50)
20,64 (.8125) pitch diameter
N˚ 2 OUTLET PORT 19,03 (.7493) TIF diameter max.
3/4" - 16 UNF 2B THD. 22,13/22,15 (.873/.872) major dia.
or G 1/2" 18,63/18,35 (.7335/7225) minor dia.
Clockwise
rotation
A .187 SQ. KEY
B 58,70 1.25 LONG 146,10
A
C (2.31) (5.75)
73,2 Ø 120.7
45˚ VIEW - AA 26,90 (2.88) (DIA. 4.75)
(1.06)

A
(3.00)
76,20

(2.62)
66,50
10˚

10˚
(2.19)

(2.00)
55,60

50,8

R 14.2
(R .56)
.3 0
(2 0,5
8)

Ø 101,60 / 101,55
6

(DIA. 4.000/3.998)
Ø 24,54 / 24,41
55,60 22,23

(DIA. .966/.961)
Ø 22,20
(2.19)
(DIA. .875/.874)
Ø 14.2 (DIA. .56)
111,20 THRU 2 HOLES
(4.38)

Rated Delivery, gpm


@ 1200 rpm & 100 psi Dimensions Weight
Kg (lb)
Shaft end Cover end A B C
7, 8 or 9 1, 2 or 3 213,1 (8.39) 189,2 (7.45) 113,3 (4.46)
7, 8 or 9 4 or 5 219,5 (8.64) 195,6 (7.70) 113,3 (4.46)
7, 8 or 9 6 or 7 224,5 (8.84) 200,7 (7.90) 113,3 (4.46)
11 1, 2 or 3 218,2 (8.59) 194,3 (7.65) 118,1 (4.65)
11 4 or 5 224,5 (8.84) 200,7 (7.90) 118,1 (4.65) 13,6 (30)
11 6 or 7 229,6 (9.04) 205,7 (8.10) 121,7 (4.79)
12 or 13 1, 2 or 3 221,7 (8.73) 197,9 (7.79) 121,7 (4.79)
12 or 13 4 or 5 227,8 (8.97) 204,0 (8.03) 121,7 (4.79)
12 or 13 6 or 7 232,9 (9.17) 209,0 (8.23) 121,7 (4.79)

INTERNAL LEAKAGE (TYPICAL) NOISE LEVEL (TYPICAL)


SDV2010 - 13 - 6
Lp. Noise level [db(A)] 1 m ISO 4412

6 75
1.5
Internal leakage qVs l/min [GPM]

V20 7, 8 & 9 rings


V20 12 & 13 rings 1200 RPM
1.25

5 V20 6 ring 1500 RPM


1800 RPM
V20 11 ring
V10 6 & 7 rings
1.0

4 70
V10 4 & 5 rings
V10 1, 2 & 3 rings
.75

2
.50

65

1
.25

0 60
0

0 40 80 120 160 200


0 35 70 105 140 175
0 500 1000 1500 2000 2500 0 580 1160 1740 2300 2900

Pressure p bar [PSI] Pressure p bar [PSI]


Do not operate pump more than 5 seconds at any speed or vis- Double pump noise level is given with each section discharging
cosity if internal leakage is higher than 50% of theoretical flow. at the pressure noted on the curve.
Total leakage is the sum of each section loss at its operating
conditions.

Parker Hannifin
9 Back To The Table Of Content Denison Vane Pump Division
Vierzon - France
ORDERING CODE - SDV2020 SERIES

Model No. SDV 2020 - 1 F 13 S 8 S - 1 CC - L

Vane pump Shaft rotation (view on shaft end)


L = Left hand for counter-clockwise
Series Omit for right hand
2020
Position of outlet port (Viewed from
Mounting cover end of pump)
1 = 2-bolt flange, 4” pilot (standard) With n°1 outlet opposite inlet
6 = 2-bolt flange, 3”1/4 pilot (optional) AA = N° 2 outlet opposite inlet
Inlet port connections AB = N° 2 outlet 90° CCW from inlet
F = 4 bolt flange 2.00 dia AC = N° 2 outlet in line with inlet
AD = N° 2 outlet 90° CW from inlet
Shaft-end pump ring size With n°1 outlet 90° CCW from inlet
(Delivery at 1200 rpm and 100 psi) BA = N° 2 outlet opposite inlet
6 = 6 USgpm BB = N° 2 outlet 90° CCW from inlet
7 = 7 USgpm BC = N° 2 outlet in line with inlet
8 = 8 USgpm BD = N° 2 outlet 90° CW from inlet
9 = 9 USgpm With n°1 outlet in line with inlet
11 = 11 USgpm CA = N° 2 outlet opposite inlet
12 = 12 USgpm CB = N° 2 outlet 90° CCW from inlet
13 = 13 USgpm CC = N° 2 outlet in line with inlet
No 1 outlet port (shaft end) CD = N° 2 outlet 90° CW from inlet
S = 1”1/16 - 12 UNF-2B thd With n°1 outlet 90° CW from inlet
B = G 3/4” (BSPP) DA = N° 2 outlet opposite inlet
DB = N° 2 outlet 90° CCW from inlet
Cover-end pump ring size DC = N° 2 outlet in line with inlet
(Delivery at 1200 rpm and 100 psi DD = N° 2 outlet 90° CW from inlet
6 = 6 USgpm
7 = 7 USgpm Shaft
8 = 8 USgpm 1 = Straight keyed
9 = 9 USgpm 11 = Splined
11 = 11 USgpm N° 2 outlet port (cover end)
S = 1”1/16 - 12 UNF-2B thread
B = G 3/4” (BSPP)
OPERATING CHARACTERISTICS
Displ. Max. Typical delivery Typical input power
Model Ring Speed
cm3/rev Pressure L/min (Usgpm) KW (hp)
Series Size RPM
(in3/rev) bar (psi) 0 bar 0 PSI 150 bar 2000 PSI 7 bar 80 PSI 175 bar 2500 PSI
1200 23,40 6,18 19,80 5,23 0,4 0,5 6,8 9,1
6 19,5 (1.19) 172 (2500) 1500 29,25 7,73 25,65 6,78 0,5 0,6 8,8 11,8
1800 35,10 9,27 31,50 8,32 0,5 0,7 10,8 14,5
1200 27,36 7,23 21,96 5,80 0,4 0,6 7,5 10,1
7 22,8 (1.39) 172 (2500) 1500 34,20 9,04 28,80 7,61 0,5 0,7 9,9 13,3
1800 41,04 10,84 35,64 9,42 0,6 0,9 12,2 16,4
1200 31,80 8,40 26,40 6,97 0,5 0,7 9,1 12,1
8 26,5 (1.62) 172 (2500) 1500 39,75 10,50 34,35 9,08 0,6 0,8 11,8 15,8
P1 1800 47,70 12,60 42,30 11,18 0,7 1,0 14,5 19,5
1200 35,64 9,42 30,24 7,99 0,6 0,7 10,4 13,9
& 9 29,7 (1.81) 172 (2500) 1500 44,55 11,77 39,15 10,34 0,7 0,9 13,4 18,0
1800 53,46 14,12 48,06 12,70 0,8 1,1 16,5 22,1
P2 1200 43,68 11,54 40,28 10,64 0,7 0,9 13,8 18,5
11 36,4 (2.22) 172 (2500) 1500 54,60 14,43 51,20 13,53 0,8 1,1 17,6 23,6
1800 65,52 17,31 62,12 16,41 1,0 1,4 21,3 28,6
1200 46,80 12,36 42,60 11,25 0,7 1,0 14,6 19,6
12 39,0 (2.38) 152 (2200) 1500 58,50 15,46 54,30 14,35 0,9 1,2 18,6 25,0
1800 70,20 18,55 66,00 17,44 1,1 1,5 22,6 30,4
1200 50,88 13,44 46,68 12,33 0,8 1,1 16,0 21,5
13 42,4 (2.59) 152 (2200) 1500 63,60 16,80 59,40 15,69 1,0 1,3 20,4 27,3
1800 76,32 20,16 72,12 19,05 1,2 1,6 24,7 33,2

Parker Hannifin
10 Back To The Table Of Content Denison Vane Pump Division
Vierzon - France
DIMENSIONS - Weight : 15,9 Kg (35 lb) - SDV2020 SERIES

Number 11 shaft
12,70
42,80
1/2" - 13 UNC - 2B thd. (.50) 41,10
(1.687)
.94 deep - 4 holes 21,40 (.843) 7,8 (.31) (1.62)

(DIA. 1.150)
9,40

Ø 29,20
(3.70)

(3.063)
77,80

(1.531)
38,90

(DIA. .703)
N˚ 1 outlet port Involute spline

Ø 17,90
1"1/16 - 12 UNF - 2B thd. Major diameter fit
or G 3/4" 16/32 diametral pitch
N˚ 2 outlet port 13 teeth
1"1/16 - 12 UNF - 2B thd. Inlet port 30˚ pressure angle
or G 3/4" Ø 50.8 (DIA. 2.00) 20,64 (.8125) pitch diameter
19,03 (.7493) TIF diameter max.
26,90
22,13/22,15 (.873/.872) major dia.
C (1.06)
18,63/18,35 (.7335/7225) minor dia.
B Clockwise
Sq 4,8 (.187) key
A rotation
31,8 (1.25) long

58,70 Ø 174,80
(2.31) (6.88)

24,54 / 24,41
(.966/.961)
(2.75)
74,70
(2.94)

69,80

(2.62)
66,50
(DIA. 4.000/3.995)
Ø 101,60 / 101,55
(2.19)
55,60

Ø 14.3 (DIA. .562)


Ø 146.05 thru - 2 holes
55,60 (DIA. 5.75)
SAE "B" Ø 121
(2.19) (DIA. 4.75)
111,20 flange
(4.38) Number 1 shaft
Ø 22,23 / 22,20
(DIA .875/.874)

Ring size Dimensions Weight


Kg (lb)
Shaft end Cover end A B C
7, 8 or 9 6 213,6 (8.41) 187,7 (7.39) 114,0 (4.49)
7, 8 or 9 7, 8 or 9 220,0 (8.66) 194,0 (7.64) 114,0 (4.49)
11 6 218,7 (8.61) 192,8 (7.59) 119,1 (4.69)
11 7, 8 or 9 225,0 (8.86) 199,1 (7.84) 119,1 (4.69) 15,9 (35)
11 11 229,9 (9.05) 204,0 (8.03) 119,1 (4.69)
12 or 13 6 222,2 (8.75) 196,3 (7.73) 122,4 (4.82)
12 or 13 7, 8 or 9 228,3 (8.99) 202,4 (7.97) 122,1 (4.82)
12 or 13 11 233,4 (9.19) 207,5 (8.17) 122,4 (4.82)

INTERNAL LEAKAGE (TYPICAL) NOISE LEVEL (TYPICAL)


SDV2020 - 13 - 11
Lp. Noise level [db(A)] 1 m ISO 4412

6 75
1.5
Internal leakage qVs l/min [GPM]

7,8 & 9 rings


1200 RPM
12 & 13 rings
1.25

5 1500 RPM
6 ring 1800 RPM
11 ring
1.0

4 70
.75

2
.50

65
.25

0 60
0

0 40 80 120 160 200


0 35 70 105 140
0 500 1000 1500 2000 0 580 1160 1740 2300 2900

Pressure p bar [PSI] Pressure p bar [PSI]


Do not operate pump more than 5 seconds at any speed or vis- Double pump noise level is given with each section discharging
cosity if internal leakage is higher than 50% of theoretical flow. at the pressure noted on the curve.
Total leakage is the sum of each section loss at its operating
conditions.

Parker Hannifin
11 Back To The Table Of Content Denison Vane Pump Division
Vierzon - France

You might also like