Simpson Strong-Tie® Wood Construction Connectors — Canadian Limit States Design

CB/CBGT
Column Bases
15/16" for 5/8" bolts
CB — For columns that require high structural values 11/2" for 3/4" bolts
and rugged performance.

ts
Material: See table

bol

ts
bol
5/8"
Finish: CB44, CB46, CB48, CB66, CB68,

3/4"
For
Bases and Caps

CB610 — galvanized; all others (including all CBGT) —

For
Simpson Strong-Tie® gray paint. Some models
available in HDG, stainless steel or black powder coat
(Note: when ordering powder coat, model number
is CBxxPC.)
Installation:
• Use all specified fasteners; see General Notes.
• For full capacities, minimum 3" side cover is required.
• Install all models with bottom of base plate flush
with concrete. CB44
(CB46, CB48, CB64, CB66, Configuration of all
• Post bases do not provide adequate resistance to CB68, CB86, CB88, other CB sizes
prevent members from rotating about the base and CB610 similar) (Standard finish –
therefore are not recommended for non-top-supported (Standard finish – G90) gray paint)
installations (such as fences or unbraced carports).
• Contact engineered wood manufacturers for
connections that are not through the wide face.
Options:
• Other sizes available, specify W1 and W2 dimensions.
Consult Simpson Strong-Tie for bolt sizes and factored
resistances.
• For rebar option add “GT” to the model name, i.e.,
CBGT44. (Base plate comes 3 ga. for all CBGTs).
15M
rebar

C-C-CAN2020 © 2020 SIMPSON STRONG-TIE COMPANY INC.


CBGT
olts
For 3 lts
⁄4" b
o
⁄8" b
For 5

3" min.
side 3" min. 3" min.
cover side side
cover cover

3" min. cover (typ.)

CB9
(CB5, CB7 similar) Typical CBGT
for Glulam Column Installation
80
Simpson Strong-Tie® Wood Construction Connectors — Canadian Limit States Design

CB/CBGT
Column Bases (cont.)
These products are available with additional corrosion protection. For more information, see p. 20.

Dimensions Column Factored Uplift


Material
(in.) Bolts Resistance (K D = 1.15)
Nominal
Model D.Fir–L S-P-F
Column
No. Strap Base Dia.
Size W1 W2 D Qty. lb. lb.

Bases and Caps


(ga. x W) (ga.) (in.)
kN kN
5582 4407
CB44 4x4 7 ga. x 2 7 3 9⁄16 3 9⁄16 8 2 5/8
24.83 19.60
5582 4407
CB46 4x6 7 ga. x 2 7 3 9⁄16 5 1⁄2 8 2 5/8
24.83 19.60
5582 4407
CB48 4x8 7 ga. x 2 7 3 9⁄16 7 1⁄2 8 2 5/8
24.83 19.60
5940 4690
CB5-4.5 Glulam 7 ga. x 3 7 4 1⁄2 5 1/8 8 2 5/8
26.42 20.86
5940 4690
CB5-6 Glulam 7 ga. x 3 7 6 5 1/8 8 2 5/8
26.42 20.86
5940 4690
CB64 6x4 7 ga. x 3 7 5 1⁄2 3 9⁄16 8 2 5/8
26.42 20.86
5940 4690
CB66 6x6 7 ga. x 3 7 5 1⁄2 5 1⁄2 8 2 5/8
26.42 20.86
5940 4690
CB6-7 6x 7 ga. x 3 7 5 1⁄2 7 8 2 5/8
26.42 20.86
5940 4690
CB68 6x8 7 ga. x 3 7 5 1⁄2 7 1⁄2 8 2 5/8
26.42 20.86
5940 4690
CB610 6x10 7 ga. x 3 7 5 1⁄2 9 1⁄2 8 2 5/8
26.42 20.86
5940 4690
CB612 6x12 7 ga. x 3 7 5 1⁄2 11 1⁄2 8 2 5/8
26.42 20.86
9410 7530
CB7-6 Glulam 3 ga. x 3 7 6 6 3/4 8 2 3/4
41.86 33.50
9410 7530
CB7-7.5 Glulam 3 ga. x 3 7 7 1⁄2 6 3/4 8 2 3/4
41.86 33.50
9410 7530
C-C-CAN2020 © 2020 SIMPSON STRONG-TIE COMPANY INC.

CB7-9 Glulam 3 ga. x 3 7 9 6 3/4 8 2 3/4


41.86 33.50
9410 7530
CB7-10.5 Glulam 3 ga. x 3 7 10 1⁄2 6 3/4 8 2 3/4
41.86 33.50
8470 —
CB7 1/8-4 PSL 3 ga. x 3 7 7 1/8 3 1⁄2 8 2 3/4
37.68 —
8470 —
CB7 1/8-6 PSL 3 ga. x 3 7 7 1/8 5 1⁄2 8 2 3/4
37.68 —
9410 —
CB7 1/8-7 PSL 3 ga. x 3 7 7 1/8 7 8 2 3/4 1. Factored uplift resistances have
41.86 —
been increased 15% for earthquake
9410 7530 or wind loading, with no further
CB86 8x6 3 ga. x 3 7 7 1⁄2 5 1⁄2 8 2 3/4
41.86 33.50 increase allowed; reduce where
9410 7530 other loads govern.
CB88 8x8 3 ga. x 3 7 7 1⁄2 7 1⁄2 8 2 3/4 2. PSL is parallel strand lumber.
41.86 33.50
3. Factored resistances shown assume
9410 7530 dry service condition (KSF = 1.00).
CB9-6 Glulam 3 ga. x 3 7 6 8 3/4 8 2 3/4
41.86 33.50 Multiply table values by 0.67 for uplift
under wet service conditions.
9410 7530
CB9-7.5 Glulam 3 ga. x 3 7 7 1⁄2 8 3/4 8 2 3/4 4. Factored uplift resistance for CBGT
41.86 33.50 option is 4350 lb. (19.35 kN).
9410 7530 5. LCB products must be installed with
CB9-9 Glulam 3 ga. x 3 7 9 8 3/4 8 2 3/4 bolts to achieve table values.
41.86 33.50
6. Designer is responsible for concrete
9410 7530 design.
CB9-10.5 Glulam 3 ga. x 3 7 10 1⁄2 8 3/4 8 2 3/4
41.86 33.50 7. Structural composite lumber columns
9410 7530 have sides that show either the wide
CB1010 10x10 3 ga. x 3 3 9 1⁄2 9 1⁄2 8 2 3/4 face or the edges of the lumber
41.86 33.50 strands/veneers. Values in the tables
9410 7530 reflect installation into the wide face.
CB1012 10x12 3 ga. x 3 3 9 1⁄2 11 1⁄2 8 2 3/4 8. f'c shall be 20 MPa minimum.
41.86 33.50
9. Nails: 16d = 0.162" dia. x 3 1⁄2" long.
9410 7530
CB1212 12x12 3 ga. x 3 3 11 1⁄2 11 1⁄2 8 2 3/4 See pp. 22–23 for other nail sizes
41.86 33.50 and information.