0% found this document useful (0 votes)
65 views4 pages

XB06

The document describes the Danfoss Micro Plate Heat Exchanger model XB06. It is a brazed copper heat exchanger designed for district heating and cooling applications. It uses micro-plate technology for more efficient heat transfer compared to previous models. Benefits include energy savings, better heat transfer, lower pressure loss, and a longer lifetime. Technical specifications are provided for connections, materials, insulation, dimensions, and weight.

Uploaded by

ahmed ewis
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
65 views4 pages

XB06

The document describes the Danfoss Micro Plate Heat Exchanger model XB06. It is a brazed copper heat exchanger designed for district heating and cooling applications. It uses micro-plate technology for more efficient heat transfer compared to previous models. Benefits include energy savings, better heat transfer, lower pressure loss, and a longer lifetime. Technical specifications are provided for connections, materials, insulation, dimensions, and weight.

Uploaded by

ahmed ewis
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Data sheet

Micro Plate Heat Exchanger (MPHE): XB06

Description Micro Plate Heat Exchangers - a revolutionary


technology from Danfoss.
Characterized by their unique plate pattern,
MPHEs enable heat to be transferred more
efficient than any previous model of heat
exchangers.

Benefits:
• Energy and cost savings
• Better heat transfer
• Lower pressure loss
• More flexible design
• Longer life time

more on:
MPHE.danfoss.com

XB 06 is copper brazed heat exchanger, designed


and configured for District Heating, District
Cooling and other Heating applications.

Approval:
Pressure Equipment Directive (PED) 97/23/EC.

Ordering 1-pass heat exchanger XB 06


XB 06L-1 XB 06H-1 XB 06H+
Picture No. of plates, n Connection
Code No.
8 004B2024 004B2036 004B1206
10 004B2025 004B2037 004B1207
16 004B2026 004B2038 004B1209
20 004B2027 004B2039 004B1211
26 004B2028 004B2041 004B1212
30 004B2029 004B2042 004B1214
Thread G ¾ A
36 004B2030 004B2043 004B1216
40 004B2031 004B2044 004B1217
50 004B2032 004B2046 004B1219
60 004B2033 004B2047 004B1221
70 004B2034 004B2048 004B1222
80 - - 004B1223

DEN-SMT/SI VD.GS.V1.02 © Danfoss 06/2014 1


Data sheet Micro Plate Heat Exchanger (MPHE) XB06

Ordering (continued) Accessories-Tailpieces Accessories-Insulation XB 06-1


Picture Description Connection Code No.1) Picture No. of plates, n Code No.
Solder G ¾ A/15 mm 004B2945
tailpieces 8-26 004B1191
G ¾ A/18 mm 004B2946
Weld-on
G ¾ A/DN 20 004B2944
tailpieces 30-40 004B1192
Threaded G ¾ A/G ¾ A 004B2947
tailpieces G ¾ A/G 1 A 004B2953 50-70 004B1193
1)
One set contains 2 tailpieces with union nuts and gaskets

Accessories-Bracket Accessories-Insulation XB 06H+


Picture Code No. Picture No. of plates, n Code No.

8-36 004B1191

004B2948
40-70 004B1192

80 004B1193

Technical data Type XB 06L-1 XB 06H-1 XB 06H+


Max. working pressure bar 25 (16) 1) 25
Min. / Max. temperature °C -10/180
DH: Circulation water / glycolic water up to 50%
Flow medium DC: ethylene-, propylene-glycolic water, ethanol-water solutions and other
suitable heat transfer media. (Please contact your Danfoss representative).
Volume / Channel Ltr 0,034 0,023 0,018
Connection type Cylindrical external thread acc. to DIN ISO 228/1
Connection size G¾A
Weight kg 0,67 + 0,08 × n 0,6 + 0,07 × n
Materials
Plate Stainless steel, mat. no. 1.4404
Brazing Copper

Insulation
Type PU (Polyurethane)
Wall thickness mm 20
Heatconductivity, λ W/mK 0,035
Permanent 130
Max temperature °C
Short term peak 160
1)
16 bar versions are available on enquiry

2 VD.GS.V1.02 © Danfoss 06/2014 DEN-SMT/SI


Data sheet Micro Plate Heat Exchanger (MPHE) XB06

Dimension

E
20
E Weight empty
Type Connection
(mm) (kg)

320 XB 06 L-… 7 + 1,6 × n


0,67 + n × 0,08
270 XB 06 H-… G ¾ A 1) 7 + 1,25 × n
XB 06H+ … 7 + 0,95 × n 0,6 + n × 0,07
95 n = number of plates
1)
Cylindrical external thread acc, to DIN ISO 228/1

45

Mounting brackets Insulation XB 06-1


No. of A B E
Code No.
plates mm
60 8,5
E

Ø 8-26 140 98 004B1191
20 30-40 368 145 138 004B1192
60
50-70 150 168 004B1193
45 A
Insulation XB 06H+
7
Ø2 No. of A B E
Code No.
plates mm
202
180 B 8-36 140 98 004B1191
40-70 368 145 138 004B1192
80 150 168 004B1193

100 100

Tailpieces
a b SW 1)
Picture Description Connection Code No.
mm
b G ¾ A / 15 mm 15 35 32 004B2945
solder b
b a Solder
solder
solder tailpieces
tailpieces aa G ¾ A / 18 mm 18 35 32 004B2946
tailpieces
tailpieces
b
weld-on b
b a
weld-on
weld-on
Weld-on
G ¾ A / DN 20 21,2 35 32 004B2944
tailpieces aa tailpieces
tailpieces
tailpieces
b
threaded b
b a
threaded G¾A/G¾A 3/4” 40 32 004B2947
threaded
tailpieces aa Threaded
tailpieces
tailpieces
tailpieces
G¾A/G1A 1” 22 32 004B2953
1)
Union nut, width across flats

DEN-SMT/SI VD.GS.V1.02 © Danfoss 06/2014 3


Data sheet Micro Plate Heat Exchanger (MPHE) XB06