General Notes and Detailing-Model

This document provides design notes and specifications for a steel structure including: - Column sizes of 356 x 406 x 287 mm made of S355 steel with various fixed and pinned connections. - Beams of size 610 x 305 x 179 mm made of S355 steel to support imposed and permanent loads. - 140 x 140 x 12.5 mm hollow square steel sections for the roof structure. - Bolted connections between beams, columns, and trusses using 24 mm diameter bolts grade 8.8 or higher. - Foundations to be designed by a professional engineer after inspection and testing by a geotechnical firm. - Brick walls to be reinforced according to schedules and meet construction standards.

Uploaded by

Wee Ren
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
28 views1 page

General Notes and Detailing-Model

This document provides design notes and specifications for a steel structure including: - Column sizes of 356 x 406 x 287 mm made of S355 steel with various fixed and pinned connections. - Beams of size 610 x 305 x 179 mm made of S355 steel to support imposed and permanent loads. - 140 x 140 x 12.5 mm hollow square steel sections for the roof structure. - Bolted connections between beams, columns, and trusses using 24 mm diameter bolts grade 8.8 or higher. - Foundations to be designed by a professional engineer after inspection and testing by a geotechnical firm. - Brick walls to be reinforced according to schedules and meet construction standards.

Uploaded by

Wee Ren
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

PRODUCED BY AN AUTODESK STUDENT VERSION

General Notes Column Design


Column size: 356 x 406 x 287 S355
1. The drawing is prepared using standard of professional care and completeness normally
Column B/1, B/6, D/1, D/6 : Fixed to free column (Roof - 3F)
exercise under similar circumstances by reputable structural engineer in this or similar localities. Fixed to fixed column ( GF-1F, 1F-2F, 2F-3F)
2. The contractor shall have working knowledge on the applicable federal and state codes, Column B/3, B/4, C/3, C/4, D/3, D/4 : Fixed to free column (Roof - 3F)
standard,requirement, regulations and laws. Fixed to fixed column ( GF-1F, 1F-2F, 2F-3F)
Column C/1, C/6: Fixed to free column (Roof - 3F)
3. These drawings represent the complete structure but the do not show the method of
Fixed to fixed column ( GF-1F, 1F-2F, 2F-3F)
construction. Column A/2, A/3, A/4, A/5 E/2, E/3, E/4, E/5 : Fixed to pinned column (Roof - 3F)
4. The contractor should verify all the dimension, conditions and elevations to settle any Fixed to fixed column ( GF-1F, 1F-2F, 2F-3F)
dissimilarity prior to start the construction. Column A/1, E/1,A/6,E/6: Fixed to pinned column (Roof - 3F)
5.All must be supervise and control in case of there is any conflict between the notes ,details Fixed to fixed column ( GF-1F, 1F-2F, 2F-3F)
and specifications. Without the written approval and signing of engineer, contractor shall not
Connection Design
make any changing from contract documents. Truss connection
6. Standards and code references in these construction documents refer to building code Type of connection used = Bolted
specified in design of steel structure. Diameter bolt= 24mm
Grade = 8.8
7. The structure is designed for the following uniformly distributed loads:
S275
=640N/mm^2
Roof Design =800 N/mm^2
Square hollow section
140 x 140 x 12.5 S355 Beam to column
Load Analysis: Method of connection used = Bolted
Permanent Load, Gk = 0.536kN/m^2

PRODUCED BY AN AUTODESK STUDENT VERSION


Diameter bolt= 24mm
PRODUCED BY AN AUTODESK STUDENT VERSION

Imposed Load, Qk = 0.75 kN/m^2 Grade = 8.8


Spacing between purlin= 5000mm S275
Spacing between truss: Maximum = 6000mm, Minimum = 4000mm
Bottom Chord, length = 5000mm@5m Column to column
Web Member ( vertical and diagonal ), length = [email protected] Method of connection used = Bolted
Diameter bolt= 24mm
Beam & Slab Design Grade = 8.8
Beam size: 610 x 305 x 179 S355 S275
Load Analysis: Self weight beam = 179 x (9.81/1000) = 1.76 kN/m 4 beam connect to a column: Column B/2, B/3, B/4, B/5, C/2, C/3, C/4, C/5, D/2, D/3, D/4,
Permanent Load, Gk = 5kN/m^2 D/5(Ground Floor, First, Second, Third Floor)
Imposed Load, Qk = 3kN/m^2 3 beam connect to a column(A): Column C/1, C/6 (Ground Floor)
Column C/2, C/5 (First, Second, Third Floor)
Notes on Foundation Column B/1, B/6, D/1, D/6 (Ground Floor, First, Second, Third
1. Inspection, site preparation, grading tests, field observation or approval from geotechnical Floor)
engineer recommended by the geotechnical report and any agenda shall be completed prior to 3 beam connect to a column(B): Column A/2, A/3, A/4, A/5, E/2, E/3, E/4, E/5 (Ground Floor,
construction of foundations. First, Second, Third Floor)
2. Contractor shall familiar the condition of subsurface and and geotechnical report before the 2 beam connect to a column(A): Column A/1, A/6 E/1, E/6 (Ground Floor, First, Second, Third
excavation is began. Floor)
3. Method used shall be design by a professional engineer. 2 beam connect to a column(B): Column C/1, C/6 (First, Second, Third Floor)
4. Soil compaction shall be controlled by a geotechincal engineer or qualified testing laboratory.
Location of testing shall be determined by the testing agency.

Notes on Brickwall
1. All the material and skill used shall correspondingly with the applicable standards and
specification of the National Concrete Mansory Association and uniform building code.
2. All brickwall shall be reinforced according to the schedule of concrete reinforcement.

STEELMAN ENTERPRISE GROUP

140mm
SQUARE HOLLOW SECTIONS COLUMN TO COLUMN CONNECTION COLUMN TO COLUMN CONNECTION
560

140mm SHS 140 X 140 X 12.5


560

4 BEAM CONNECTED TO A COLUMN 3 BEAM CONNECTED TO A COLUMN


12.5mm
50
2000

VIEW OF WEB VIEW OF FLANGE

VIEW OF COLUMN CONNECTION

5000 5000 5000 5000

COLUMN TO COLUMN CONNECTION


2 BEAM CONNECTED TO A COLUMN (A) 2 BEAM CONNECTED TO A COLUMN (B)

PRODUCED BY AN AUTODESK STUDENT VERSION