LPT - Specifications (En)

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Drawing No. Rev.

Page

LPT-1M1-W18 C 1 / 5

SPECIFICATIONS

[1. General Specifications]


Product Name Warning Light
Model LPT-1M1-□ (□:R, Y, G, B) LPT-2M1-□ (□:R, Y, G, B)
Rated Voltage 12 - 24V DC
Operating Voltage Range 9.5 - 30V DC
Luminous Color Red (R) Amber (Y) Green (G) Blue (B) Red (R) Amber (Y) Green (G) Blue (B)
Rated Current
12V DC 0.30A 0.60A 0.50A 1.10A 1.30A 1.20A
Consumption Max.
24V DC 0.15A 0.30A 0.25A 0.55A 0.65A 0.60A
Rated Power Max. 3.6W 7.2W 6.0W 13.2W 15.6W 14.4W
Operating Ambient Temperature -30 ℃ ~ +75 ℃
Storage Ambient Temperature -30 ℃ ~ +75 ℃
Mounting Location Indoor / Outdoor *1
Mounting Direction All Directions
Protection Rating IP68(IEC 60529) (IPX8: 1 m underwater for 1 hour)/ NEMA TYPE 4X,13
Environmental Condition All Directions (excluding end of the cable)
Vibration Resistance 90m/s²
Luminous Luminous Color Red (R) Amber (Y) Green (G) Blue (B) Red (R) Amber (Y) Green (G) Blue (B)
Intensity *2 500cd 550cd 850cd 300cd 1,650cd 1,800cd 2,800cd 1,000cd
or more or more or more or more or more or more or more or more
Triple flash, Extreme Warning flash, Continuous, or Blinking
Flash pattern (4 types) *3
(for details, refer to “4.1. Flash pattern”. Factory default status: Triple flash)
Flashing Rate (Typ.) Triple / Extreme warning : 400 flashes per minute Blinking : 67 flashes per minute
Dimmer Function Yes
Number of units Maximum 20 units (The LPT-1M1-□ and LPT-2M1-□ can be used together.)
Synchronize Wire
between each unit 3m *4
Daisy-
(Maximum)
Chained
Group A / Group B
Flash group
(for details, refer to “4.2. Flash group”. Factory default status: Group A)
Multiple-unit operation Synchronized / Alternating
Items Flash pattern , Flash group
Each flash setting can be switched by applying voltage to the lead wire.
(for details, refer to “Instruction manual”.)
Setting
Method When changing from factory settings, specify the flash settings before wiring the
equipment. Also, while in operation, do not change flash patterns or flash group
settings.
Mass 72 g or less 130 g or less
Outer Dimensions Refer to the Outer Dimension Drawing
*1 Install on a flat, sturdy surface. Be sure that the product is securely mounted
when used where vibration is present.
*2 Due to the characteristics of the LED elements, there may be a slight variation in
color tone and brightness between units.
Remarks
*3 Flash Pattern (Triple flash / Blinking) meets SAE J595 Class 3.
*4 If the product interval is 3m or more, up to 4 synchronize wire can be extended to
20m each.
Drawing No. Rev. Page

LPT-1M1-W18 C 2 / 5

EMC Directive (EN61000-6-4,EN61000-6-2) *5


KC(KN61000-6-4,KN61000-6-2)
Conformity Standards
FCC Part15 SubpartB Class A
RoHS Directive (EN IEC 63000)
*5 EMC meets level ECE R10.05.
・If the equipment used with this product requires power insulation, use an insulated
power supply.
Remarks
・If you use this product in an environment where a momentary power failure occurs,
the flash may go out in time with the momentary power failure.Use this product in an
environment where momentary power failure does not occur.
[2. Model Number Configuration]

LPT- M1-
Luminous Color
R : Red
Size Y : Amber
1 : 86.0×28.0mm G : Green
2 : 114.4×43.4mm B : Blue

[3. Wiring Diagram]


3.1. When using 1unit

3.2. When using multiple units (2 or more,5 or less) in a synchronous operation

3m *4

3.3. When using multiple units (6 or more,20 or less) in a synchronous operation


・Distribute the power system into multiple system.
・You can connect up to 5 units per system. For 20 units, 4 systems are required.

*1*2 : Wiring protection (Normal Blow).Please use if necessary.


LPT-1M1-□: 1.0A Consider the total current
Remarks *1 *2
LPT-2M1-□: 2.0A consumption of the equipment in use.
Drawing No. Rev. Page

LPT-1M1-W18 C 3 / 5
[4. Flash Specifications]

4.1. Flash pattern


1cycle
Light on
Triple flash
[SAE]
Dim.
*1 *2
Light off

1cycle
Light on
Extreme
Warning
flash Dim.

Light off

Light on

Continuous
Dim.

Light off

1cycle
Light on
Blinking
[SAE]
*2 Dim.

Light off

4.2. Flash group *3

Flash Flash
Group A
*1
1 cycle

Flash Flash
Group B

half cycle 1 cycle

*1: Factory default status


Remarks *2: Meets level SAE J595 Class3.
*3:Exluding Continuous.
LPT-1M1-W18
4 / 5

株式会社 パトライト
PATLITE Corporation
LPT-1M1-W18
5 / 5

株式会社 パトライト
PATLITE Corporation