0% found this document useful (0 votes)
47 views39 pages

Ep5161a SLC

This document provides a selection guide for SLC30/40 Series combination display lights and describes: - The SLC30 and SLC40 models with various illumination face sizes and types. - Available light sources, number of units, illumination colors, voltages, and terminal screws. - Protection ratings and approvals for the lights. - Combination displays using SLC30 lights with control units of up to 30 total windows. - Specifications for the control units including switch and button types and contact ratings.

Uploaded by

berliani navitas
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
47 views39 pages

Ep5161a SLC

This document provides a selection guide for SLC30/40 Series combination display lights and describes: - The SLC30 and SLC40 models with various illumination face sizes and types. - Available light sources, number of units, illumination colors, voltages, and terminal screws. - Protection ratings and approvals for the lights. - Combination displays using SLC30 lights with control units of up to 30 total windows. - Specifications for the control units including switch and button types and contact ratings.

Uploaded by

berliani navitas
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 39

SLC30/40 Series Combination Display Lights Selection Guide

Series SLC Series Combination Display Lights


Model SLC30

An example of 15-window combination


Spot illumination is available
with Type F only.

Shape

Type F Type F
(spot illumination) Type C Type H (full) Type L Type V Type G
(Basic Size) Type H2 (2-way split)

LED lamp (LFTD)


Light Source LED Unit
(SX6S/8 base)

Basic (Type F) Half Size (Type C)


No. of Units
1 for 1 window 1 for 1 window

F, H, L, V, G C only
30mm

Type F (30 × 30mm)


30mm

F H Type H (30 × 60mm)


Illumination Face Size Type L (30 × 90mm)
C
C Type V (60 × 30mm)
V G Type G (60 × 60mm)
L Type C (15 × 30mm) (split-window)

A (amber), G (green),
A (amber), G (green),
PW (pure white) *, R (red),
Illumination Color PW (pure white), R (red),
S (blue), Y (yellow), Red (R)/G (green)
S (blue), Y (yellow)
* PW is available with Type F only

6, 12, 24V AC/DC (full voltage)


100/110, 200/220V AC (transformer)
Rated Voltage 6, 12, 24V AC/DC (full voltage)
110V DC (DC-DC converter)
100/110V AC/DC (resistor)

Lens Frame Color & Frame


Black (Munsell N1.5 equivalent)
Cover Color

Terminal Screw M3.5, Check terminal: M3

Full Voltage 1 to 200 (Type F equivalent) 1 to 50 (Type F equivalent)

No. of Transformer/Resistor
Windows 1 to 75 (Type F equivalent) —
Flasher/DC-DC
Converter

Degree of Protection IP40 (IEC 60529)

• Jumper available
Remarks
• 2-color alternate, check terminal, flasher

Approvals UL, c-UL, DEMKO, CE (Note) —

Page 5

Note: Except for DC-DC converter and resistor

1
SLC30/40 Series Combination Display Lights Selection Guide

SLC Series Combination Display Lights


SLC40

An example of 12-window combination


Spot illumination is available
with Type F only.

Type F Type F
Type C Type H Type L Type V Type G
(Basic Size) (spot illumination)

LED lamp (LSRD)


LED Unit
(BA9S/13 base)

Basic (Type F) Half Size (Type C)


1 for 1 window 1 for 1 window

F, H, L, V, G C only
40mm

Type F (40 × 40mm)


40mm

F H Type H (40 × 80mm)


C Type L (40 × 120mm)
C Type V (80 × 40mm)
V G Type G (80 × 80mm)
L Type C (20 × 40mm) (split-window)

A (amber), G (green),
A (amber), G (green),
PW (pure white) *, R (red),
PW (pure white), R (red),
S (blue), Y (yellow), Red (R)/G (green)
S (blue), Y (yellow)
* PW is available with Type F only

12, 24V AC/DC (full voltage)


100/110, 200/220V AC (transformer)
6, 12, 24V AC/DC (full voltage)
110V DC (DC-DC converter)
100/110V AC/DC (resistor)

Black (Munsell N1.5 equivalent)

M3.5
2-color illumination, Type C, Check terminal: M3

1 to 126 (Type F equivalent) 1 to 105 (Type F equivalent)

1 to 60 (Type F equivalent) —

IP40 (IEC 60529)

• Extensive windows are easy to recognize at high places.


• Jumper available
• 2-color alternate, flasher, check terminal

UL, c-UL, DEMKO, CE (Note) —

14

Note: Except DC-DC converter, resistor

2
SLC30/40 Series Combination Display Lights Selection Guide

Series Combination Display with Control Units


Model SLC30 Series (SLC30 + SLC-LW)

Shape

• Combination display lights: 29 maximum


No. of Windows Total 30 maximum
• Control units: 10 maximum (the bottom row only)

• SLC30 series one-color (window 30 × 30mm)


Combination Display Lights
• Illumination color: A (amber), G (green), PW (pure white), R (red), S (blue), Y (yellow)

Rated voltage: 24V AC/DC


Ratings
Operating voltage: 24V AC/DC ±10%

• Pushbutton (square, round with square bezel, momentary)


• Illuminated pushbutton (square, round with square bezel, momentary)
Control Unit
• Selector switch (2, 3 positions, round with square bezel)
• Key selector switch (2, 3 positions, round with square bezel)

• Rated insulation voltage: 250V AC/DC


Contact Ratings • Rated current: 3A/gold, 5A/silver
(Resistive Load) • Gold contact: 125V AC/0.1A, 30V DC/0.1A
• Silver contact: 125V AC/3A, 250V AC/2A, 30V DC/2A, 125V DC/0.4A

Lens Frame Color & Frame


Black (Munsell N1.5 equivalent)
Cover Color

Degree of Protection IP40 (IEC 60529)


Page 37

<IP65 Degree of Protection Pilot Lights>


The following control square flush pilot lights can be mounted collectively to design a panel similar to combination display lights.

SLC30 series equivalent Collective Mounting Example (HN2P)


HW2P-1

Front Back
Flange size 30
Mounting hole ø22
Degree of protection IP65 (IEC 60529)

3
SLC30 Series Combination Display Lights
Highly bright “Super LED” unit improves visibility and safety.
• Eight types of illumination faces to choose
from. Compact combination display lights. An Example of 15-window size
• Super bright Super LED.
• The fingersafe spring-up terminals reduce Spot illumination is
available with type F only.
wiring time and prevent electrical shocks.
• The insulated jumper, when used on
fingersafe spring-up terminals, eliminates
the need of terminal cover.
• Legends can be engraved on the attached
marking plate. One or two thin marking
sheets (not attached) can also be installed
(Type F only).
• Spot illumination available for easy recognition
in bright environment (Type F only)
• UL and c-UL recognized, EN compliant.

(*1)

1) Except for EN60947-5-1 DC-DC converter and resistor types.


See website for details.

Type F Type F Type C Type H (full) Type L Type V Type G


(spot illumination) (split- Type H2
window) (2-way illumination)

A wide variety of illumination face sizes


The fingersafe, spring-up terminals
Type F: 30H × 30W mm (Basic size) reduce wiring time.
Type F spot illumination: 30H × 30W mm
Type C: 15H × 30W mm × 2 (Split-window) The integrated terminal cover and
Type H: 30H × 60W mm insulated jumpers prevent electic
Type H2: 30H × 60W (2-way split) shocks.
Type L: 30H × 90W mm Application Example of Jumpers
Type V: 60H × 30W mm
Type G: 60H × 60W mm
Combined construction is available.

Type F Window Spot Illumination Kit


White Screen

24V AC/DC one-color Clear Marking


full only.
Plate Marking films can be used for
Spot illumination LED Type F only
unit is necessary.

Frame (metal) Available up to 200 windows


The frame cover and frame are molded 10 rows by 26 columns maximum
in one piece for one-, two-, and three- Type F: 6, 12, 24V AC/DC
window types. See page 36 for details.

Columns
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
1
Rows 2
3
4
LED 5
6
7
8
9
10 Maximum Number
of Windows

LED Lamp • For 110/220V AC type, up to 75 windows (Type F equivalent) can be


mounted.
LED Unit Spot Illumination (SX6S/8 base) • For Type C, up to 50 windows (Type F equivalent) can be mounted.
LED Unit For Type C only
• Lighting limitations should be considered in any application.
For details see page 32.

4
SLC30 Series Combination Display Lights

Configuration
Illumination Face
• See page 31 for the
combination of illumination Type H
windows. Type F Type C Type L Type V Type G
Type H2
• Lens (acrylic) • Lens (acrylic)

• Marking Plate (acrylic) • Marking Plate


(clear, white, color) (acrylic)
(clear, white, color)
Spot Illumination
• Lens Frame (resin) • Lens Frame (resin)

Type F, H, H2, L, V, G
Marking Plate/Color Screen
Display Color Type Light Source Lens ON Color (Color Code) OFF Color
(one each) (Note 2)
Standard amber (A), blue (S), green (G), pure white (PW), red (R), yellow (Y),
clear / white White
(using clear lens) Clear red/green 2-color alternate (RG) (Note 1)
Lens Same as
Color Screen LED Unit color / white amber (TA), blue (TS), green (TG), red (TR), yellow (TY)
ON color
Gray amber (SA), blue (SS), green (SG), pure white (SPW),
Gray Lens black (Note 3) / clear Lens: gray Legend Color Gray
Lens red (SR), yellow (SY)
Note 1: Spot illumination is not available with red/green 2-color alternate (RG).
Note 2: The order to insert clear marking plate, color screen, and white screen can be interchanged if necessary.
Marking plate/color screen are interchangeable. Engrave markings on the flat surface of the plate or screen next to the lens.
Note 3: Black marking plate has black coating. Engrave a reverse legend on the black-coated surface.

Type C (split-window)
Marking Plate/Color Screens
Display Color Type Light Source Lens ON Color (Color Code) OFF Color
(one each)(Note 4)

Standard color / white Clear amber (A), blue (S), green (G), red (R), yellow (Y),
White
(using clear lens) clear / white Lens pure white (PW)
LED Lamp
black (Note 5) / color Gray amber (SA), blue (SS), green (SG), red (SR), yellow (SY)
Gray Lens Lens: gray Legend Color Gray
Lens
black (Note 5) / clear pure white (SPW)
Note 4: The order to insert clear marking plate, color screen, and white screen can be interchanged if necessary.
Marking plate/color screen are interchangeable. Engrave markings on the flat surface of the plate or screen next to the lens.
Note 5: Black marking plate has black coating. Engrave a reverse legend on the black-coated surface.

(V)
Combination Example of 15 Windows

(F) Frame Cover


(L) Black (B)
(H)
• LED Unit • LED Unit for
(G)
Spot Illumination (F)
(C)
(C)

Mounting Clip
• LED Lamp (for Type C only, SLC-3K1
SX6S/8 base) (2 lamps for 1 (supplied)
window equivalent to Type F)

One-color full One-color full One-color full Two-color Alternate


(w/check terminal) (Flasher)

6, 12, 24V AC/DC 24V DC (Except Type C) 24V DC (Type F only) 24V AC/DC (Except Type C)
One-color full One-color full One-color full

100/110V, 200/220V AC 100/110V DC (Resistor 110V DC (DC-DC Converter)


(Except Type C) Type) (Except Type C) (Except Type C)

• 2-way split is also available in Type H2.


• The illustration above shows combination examples of windows.
One-window type is available in Type F (see page 10 and 11).

5
SLC30 Series Combination Display Lights

Specifications
Light Source LED Unit LED Lamp
DC-DC
Input Full Voltage Transformer Resistor Full Voltage
Converter
One-color
Two-color One-color × 2
Illumination One-color w/check terminal Flasher One-color
Alternate Split-window (Type C)
(Note 1)
Fingersafe Spring-up Provided —
(Note 2) Provided Provided
Terminal (except for check terminal) (Note 2)
Rated Voltage 12V AC/DC 24V AC/DC 24V AC/DC 24V DC 100/110V AC ±10% 110V DC 100/110V 6V AC/DC 12V AC/DC 24V AC/DC
(AC: 50/60Hz) ±10% ±10% ±10% ±10% 200/220V AC ±10% (90 to 140V DC) AC/DC ±10% ±10% ±10% ±10%
Maximum Current 0.5W +
Same as internal LED Unit 1.7 1.4 1.5 Same as internal LED
Draw (VA) internal LED

Amber, blue, Amber, blue, green,


Amber, green, Red/green
Illumination Color green, pure white, Amber, blue, green, pure white, red, yellow pure white (Note 8),
red, yellow Alternate
red, yellow red, yellow

Standards UL, c-UL listed, EN compliant — —

Rated Voltage 12V AC/DC 24V AC/DC 24V DC 24V AC/DC 6V AC/DC 12V AC/DC 24V AC/DC

Amber, red 12 mA 12 mA (Note 6) 12 mA (Note 6)


Rated Current

7 mA 8 mA 8 mA
Green,
Red: 12 mA (Note 7) (Note 7) (Note 7)
pure white, 12 mA 11 mA (Note 6) 11 mA (Note 6)
Built-in LED Unit/Lamp

Green: 11 mA
yellow
Blue 12 mA 11 mA (Note 6) 11 mA (Note 6) 7 mA (Note 7) 8 mA (Note 7) 8 mA (Note 7)
Amber (A), blue (S), green (G),
Illumination Color Red (R)/ Amber (A), blue (S), green (G), Amber (A), blue (S), green (G),
red (R), pure white (PW),
(code) green (G) pure white (PW), red (R), yellow (Y) pure white (PW), red (R)
yellow (Y) (Note 5)
Base Plug-in unit type SX6S/8
LED Life (reference) Approx. 50,000 hours (when used on complete DC, luminance reduces to 50% of the initial intensity)

Part No. SLDN-31M-* SLDN-32M-* SLDN-32MW-RG SLDN-32M-∗ LFTD-6∗ LFTD-1∗ LFTD-2∗

No. of Units 1 LED unit per window of basic Type F 1 LED lamp per split-window type
Flashing Period
— 0.5 ±0.2 sec — —
(Note 3)
Insulation Resistance 100 MΩ between live and dead parts (500V DC megger)
2500V AC (1 minute) 2000V AC 2000V AC (1 minute)
Dielectric Strength 2000V AC (1 minute) between live and dead parts
between live and dead parts (1 minute) between live and dead parts
Operating
–20 to +40°C –10 to +40°C –20 to +40°C –10 to +40°C –20 to +40°C –20 to +40°C
Temperature (Note 4)
Storage Temperature –25 to +60°C (no freezing)

Operating Humidity 45 to 85% RH (no condensation)

Specify a color code in place of ∗.


Note 1: The rated voltage for w/check terminal type is 24V DC only.
Note 2: Terminal cover is available (see page 23).
Note 3: Duty 1:1. Multiple flasher type units do not synchronize with each other. Use Type F only.
Note 4: No freezing
Note 5: Blue and pure white LED is 24V AC/DC only.
Note 6: Spot illumination uses the spot illumination LED unit (SLCN-32ST-*). See page 26 for rated current.
Note 7: Rated current for DC. See page 26 for AC.
Note 8: Use pure white LED lamp for yellow (Y) illumination.

Type F (Note 9) Type C Type H / Type H2


Illumination Face Type L Type V Type G
(Basic) (Split-window) (Note 11)
Window (H × W) 30 × 30 15 × 30 30 × 60 30 × 90 60 × 30 60 × 60

Illumination Face (H × W) 28 × 28 13 × 28 28 × 58 28 × 88 58 × 28 58 × 58
Illumination Unit
Size (mm)

White color screen,


clear marking plate, 27 × 27 × 1.0 (Note 10) 12 × 27 × 1.0 27 × 57 × 1.0 (Note 11) 27 × 87 × 1.0 57 × 27 × 1.0 57 × 57 × 1.0
color screen (H × W × t)
Marking Film Applicable — — — — —
Engraving Area
25 × 25 10 × 25 25 × 55 (Note 11) 25 × 85 55 × 25 55 × 55
(white, transparent, color plates)
Material of Marking Plate & Color
Acrylic
Screen
Lens Frame Color & Frame Cover Color Black (Munsell N1.5 equivalent)

Connection Wire Solid wire: ø1.6 × 2, Stranded 2 mm2 × 2

Terminal Screw M3.5 screw, Check terminal: M3

Degree of Protection IP40 (IEC 60529)

Pollution Degree 3

• Spot illumination uses designated clear plate and color screen.


Note 9: Flasher type, pure white illumination, and spot illumination types are available in Type F only.
Note 10: Spot illumination type uses an exclusive clear marking plate and color screen.
Note 11: 2-way split type (Type H2) can use 2-way split color screen only.

6
SLC30 Series Combination Display Lights

Dimensions
[Front View] a: No. of Rows b: No. of Columns
Type F Type F Type H Type H2 (2-way split)
B = (30b + 12) B = (60b + 12)
(Spot Illumination) B=(60b+12)
21 30 30 36 60
Spot Illumination 36 60
5.3

5.5
21

21

21
A = (30a + 12)

30

30

30
A=(30a+12)
A = (30a + 12)
30

30
30
30

30
30
60
30 60

Type V Type L Type G Type C (split-window)


B = (90b + 12) B = (60b + 12) B = (30b + 12)
B = (30b + 12)

13.5
51 90 36 60 21 30 30
21 30 30
30
21

A = (30a + 12)
36

15 15
30

A = (60a + 12)
A = (30a + 12)
30
36
A = (60a + 12)

60

30

60

15 15
60

90 60 30

All dimensions in mm.

Type F Dimensions & No. of Windows (Type C, H, L, V, and G can be converted into Type F.)
Columns b 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26

Dimensions B 42 72 102 132 162 192 222 252 282 312 342 372 402 432 462 492 522 552 582 612 642 672 702 732 762 792
Rows Panel
Cut-out (D)
(35) (65) (95) (125) (155) (185) (215) (245) (275) (305) (335) (365) (395) (425) (455) (485) (515) (545) (575) (605) (635) (665) (695) (725) (755) (785)
a A (C)

01 42 (35) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
02 72 (65) 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52
03 102 (95) 3 6 9 12 15 18 21 24 27 30 33 36 39 42 45 48 51 54 57 60 63 66 69 72 75 78
04 132 (125) 4 8 12 16 20 24 28 32 36 40 44 48 52 56 60 64 68 72 76 80 84 88 92 96 100 104
05 162 (155) 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130
06 192 (185) 6 12 18 24 30 36 42 48 54 60 66 72 78 84 90 96 102 108 114 120 126 132 138 144 150 156
07 222 (215) 7 14 21 28 35 42 49 56 63 70 77 84 91 98 105 112 119 126 133 140 147 154 161 168 175 182
08 252 (245) 8 16 24 32 40 48 56 64 72 80 88 96 104 112 120 128 136 144 152 160 168 176 184 192 200 —
09 282 (275) 9 18 27 36 45 54 63 72 81 90 99 108 117 126 135 144 153 162 171 180 189 198 — — — —
10 312 (305) 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 — — — — — —

How to Read the Table Panel Cut-out (SLC30)


Determine the panel
1. The number of windows equals rows multiplied by columns. For example, for 5 rows by D thickness in consideration of
7 columns, the number of windows is 35, external dimensions are 162mm high by 22mm the weight of display lights
wide, and panel cut-out is 155mm high by 215mm wide. and wires (see page 23).
C

2. External dimensions are represented by A for rows and B for columns in boldface.
3. Panel cut-out dimensions are shown in ( ), for height (C) and width (D). Panel cut-out
tolerance is +1.0 to –0 mm (for one window: +0.6 to –0.4mm).
4. Total number of windows, dimensions, panel cut-out • Type L — Type F equivalent: 3 windows
➀ For Type C, H, L, V, and G, convert the numbers of rows Height: 1 row
[Example] and columns into Type F (basic size) equivalents. Width: 3 columns
• Type C — Type F equivalent: 2 split-windows consist • Type G — Type F equivalent: 4 windows
of one window.
Height: 2 rows
H Width: 2 columns
H 1 • Type H — Type F equivalent: 2 windows
C F Height: 1 row
C 2 Width: 2 columns
F G
C F V
C 3 • Type V — Type F equivalent: 2 windows.
L Height: 2 rows
6 Width: 1 column
4 5
2 3 ➁ The combination example at left consists of 3 rows by 6 columns.
1 ➂ The above table shows: No. of windows: 18
Dimensions: 102H × 192W mm
Panel cut-out:   95H × 185W mm

7
SLC30 Series Combination Display Lights

Dimensions
[Side & Rear Views]
Type F (Type H, L, V, and G are the same in side and rear views as Type F.)

• Full Voltage • Full Voltage • Full Voltage


• 6, 12, 24V AC/DC • One-color full w/Check Terminal 24V DC • One-color full
• One-color full • Two-color alternate 24V AC/DC • Flasher Type (Type F only)
• Spot Illumination 24V AC/DC • For applicable terminal cover, see page 23. • For applicable terminal cover, see page 23.

30 30
3030
6

6
6
Panel Thickness 0.8 to 6

Panel Thickness 0.8 to 6

0.8 to 6
Panel Thickness
55.5

59.5

83.5

Thickness
82

0.8
Panel to 6
30 M3.5 Terminal Screws
30 M3.5 Terminal Screws 6.2 4 30 M3 Check Terminal 30
9.2
9.2 M3.5 Terminal Screws 8 M3.5 Terminal Screws

14
14
14

14

30
30
30

30
• w/Check Terminal
Terminal X1 is a positive pole; Terminal X2 and • Terminals X1 and X2 are positive and
C (check terminal) are negative poles. negative poles, respectively.
• Two-color Alternate
Red (R) illumination: X1 positive, C negative
Green (G) illumination: X1 positive, X2 negative

Type C (split-window)
• Transformer • Resistor
• One-color full • One-color full • Full Voltage
• 100/110, 200/220V AC/DC • 100/110V AC/DC • 6, 12, 24V AC/DC
• 110VDC (DC-DC Converter) • One-color full, 2 × LED lamps,
Split-window type
SLC-3KL 30
30
6
6
6

Panel Thickness 0.8 to 6


Panel Thickness 0.8 to 6

Panel Thickness 0.8 to 6


200/220V AC: 72.3
110V DC : 83.5

57.5
83.5
100/110V,

30 M3.5 Terminal Screws 30 6 4 30 M3.5 Terminal Screws


9.2 9.2
7
14
14
14

X2
4
30
30
30

M3.5 Terminal Screws • Terminal X1 is COM terminal.


• For applicable terminal cover, see page 23.
• On DC-DC converter type units,
Terminals X1 and X2 are positive
and negative poles, respectively.

All dimensions in mm.

8
SLC30 Series Combination Display Lights

Dimensions
All dimensions in mm.
[One-window, Type F only]
Full Voltage 12, 24V AC/DC, One-color Full Spot Illumination
Panel Thickness 0.8 to 6 Mounting Clip SLC-3K1
5.3 Panel Cut-out
M3.5
Terminal Screws +0.6
35 –0.4

5.5

30
30

14

+0.6
–0.4
35
42 6 55.5 9.2 42

Full Voltage w/Check Terminal 24V DC / Two-color Alternate 24V AC/DC


Panel Thickness 0.8 to 6 Mounting Clip SLC-3K1 • w/Check Terminal Type
Terminal X1 is a positive pole; Terminals X2 and C
M3.5 Terminal Screws (check terminal) are negative poles.
• Two-color Alternate Type
Red (R) illumination: X1 positive, C negative
Green (G) illumination: X1 positive, X2 negative
30

14

• See page 23 for terminal covers.


M3
Check Terminal

42 6 59.5 6.2 4

Flasher 24V DC
Panel Thickness 0.8 to 6 Mounting Clip SLC-3K1 • On flasher type, Terminals X1 and X2 are positive
M3.5 and negative poles, respectively.
Terminal Screws • See page 23 for terminal covers.
30

14

42 6 83.5 9.2

Transformer 100/110, 200/220V AC


Panel Thickness 0.8 to 6 Mounting Clip SLC-3K1
M3.5
Terminal Screws
30

14

42 6 72.3 9.2

DC-DC Converter 110V DC


Panel Thickness 0.8 to 6 Mounting Clip SLC-3K1 • On DC-DC converter type, Terminals X1 and X2
M3.5 are positive and negative poles, respectively.
Terminal Screws
30

14

42 6 83.5 9.2

Resistor 100/110V AC/DC


Panel Thickness 0.8 to 6 Mounting Clip SLC-3K1 (Resistance)
M3.5 7.2 kΩ, 4W
Terminal Screws
30

14

42 6 83.5 9.2

9
SLC30 Series Combination Display Lights

Terminal Connection Terminal Connection Using Jumpers


• For one-color full with check terminal, DC-DC converter, and • For terminal connection of types F, H, L, V, and G (except Type
resistor, Terminals X1 and X2 are positive and negative poles, C), jumpers can be used as shown below.
respectively.
SLC30 Series
Terminal X1 Terminal X2 Terminal C

Fingersafe, Spring-up SLCN-JP34 SLCN-JP34



Terminal (Note 1) SLCN-JP35 SLCN-JP35
Arrows indicate
access directions for Others SLC-JP30 SLC-JP33 SLC-JP32
wiring terminals.
Note 1: Fingersafe, spring-up terminals are used in one-color full
illuminated type (6, 12, 24V AC/DC, 100/110, 200/220V AC, 110V
DC).
Fingersafe, Spring-up Other terminals • For Type C, jumpers can be used on Terminal X1 only as shown
Terminal below.
• When using Type C only
Direction
(Flasher Type Connection Diagram) • When using Type C and Two-color alternate
Vertical SLC-JP33
X1
Horizontal SLC-JP30
Positive LED Module

Flasher Note: Jumpers cannot be used when using both Type C and fingersafe
Circuit spring-up terminals.
Negative
X2 [Examples of Using Jumpers]
Fingersafe Spring-up Terminal)
• For w/check terminal and two-color alternate units, terminal X1 is
a positive pole; Terminals X2 and C (check terminal) are negative When connecting two windows
Using one SLCN-JP35 jumper
poles.
Arrows indicate access directions for
wiring terminals.
X1 (w/Check Terminal Type Connection Diagram)
C X1
Positive
When connecting three windows
C Using two SLCN-JP35 jumpers
X2 Negative LED
Module
X2
Negative

• Connection for two-color alternate is as follows. When connecting four windows


Red (R) — Terminal X1: positive, Terminal C: negative Using one SLCN-JP34 jumper
Green (G) — Terminal X1: positive, Terminal X2: negative
(Two-color alternate Type Connection Diagram)

X1
Common
Positive

C
Red (R)
Negative LED Module
Jumpers (SLCN-JP34/35) have an orientation.
Ensure that jumpers are installed correctly.
X2
Negative
Green (G)
Correct Incorrect

• For the split-window (Type C), Terminal X1 (+) is a common


terminal. Terminal X2 is a negative pole of upper illumination and
Terminal X3 is a negative pole of lower illumination. (AC/DC,
except for LFTD-5*)
Arrows indicate access directions for
wiring terminals.
X1 (Type C Spolit-window Connection Diagram)
X1
Common
X3
LFTD
X2 Upper

X2
X3
Lower

10
SLC30 Series Combination Display Lights

Part No. Development


Example: A (10), G (5), R (5)
SLC30N – 0 4 0 5 – DD 2 F B – Specify the color code and the number of windows.

30 Series When ordering Type H, L, Frame Color


V, G, or C units, enter the Black: B
equivalents of Type F.

Equivalent Operating Voltage Illumination Face Size Illumination


of Basic Size Unit (Code) (Code)
(Built-in Lamp) (Code) Color
Windows
12V AC/DC ±10% 1 • Type F • Standard Clear Lens
Rows Columns Full Voltage (A, G, R, Y) DD 30 × 30 mm Combination (Code)
01 01 24V AC/DC ±10% 2
F Amber A
02 02 Full Voltage (PW, S) DDA 24V AC/DC ±10% 2
Full Voltage / Type H2 only
Green G
03 03 DDC 24V AC/DC ±10% 2
(Combination of S and A, G, R, Y) • Type H Pure White PW
04 04 Full Voltage w/Check Terminal
DHM 24V DC ±10% 2 30 × 60 mm Red R
(A, G, R, Y)
05 05 Full Voltage Two-color Alternate H
DW 24V AC/DC ±10% 2 Blue S
06 06 (R/G)
Full Voltage Flasher (A, G, R, Y) Yellow Y
LED Unit

07 07 DF 24V DC ±10% 2
(Type F only) • Type H2 (Note 1) Red / Green RG
08 08 100/110V AC ±10% 1 (2-way split)
Transformer (A, G, R, Y) TD
09 09 200/220V AC ±10% 2 30 × 60 mm
• Color Screen
10 10 100/110V AC ±10% 1 Combination (Code)
Transformer (PW, S) TDA H2
11 200/220V AC ±10% 2 When color display is
A light barrier, clear required at power off,
12 Transformer / Type H2 only 100/110V AC ±10% 1 marking plate, and order color screens. For
TDC color screen for 2-way
details, see page 31.
13 (Combination of S and A, G, R, Y) 200/220V AC ±10% 2 split illumination are
supplied.
DC-DC Converter (A, G, R, Y) CD 110V DC (90 to 140V DC) 1
Amber TA
14
• Type L Green TG
15 Resistor (A, G, R, Y) RN 100/110V AC/DC ±10% 1
30 × 90 mm
6
Red TR
16 6V AC/DC ±10% (LFTD-6∗)
LED Lamp

One-color Full × 2 split L


window (Type C)
SX6S/8
DP 1
Blue TS
17 Base 12V AC/DC ±10% (LFTD-1∗)
(A, G, R, Y) Yellow TY
18 24V AC/DC ±10% (LFTD-2∗) 2
• Type V
19 60 × 30 mm
The following color/voltage selections are also available. • Gray Lens Combination
20 (Code)
Operating Voltage V
21 Unit (Code) (Code)
(Built-in Lamp) Amber SA
22 Full Voltage w/Check Terminal DHMA 24V DC ±10% 2 Green SG
(PW, S)
23 Full Voltage Flasher Pure White SPW
DFA 24V AC/DC ±10% 2
(PW, S) • Type V
24 Red SR
115/120V AC ±10% 12 60 × 60 mm
25 Transformer (A, G, R, Y) TD Blue SS
230/240V AC ±10% 24
G
LED Unit

26 Yellow SY
115/120V AC ±10% 12
Transformer (PW, S) TDA • Type L, V, and G
230/240V AC ±10% 24
cannot be split-
Transformer / Type H2 only 115/120V AC ±10% 12 illuminated.
TDC • Type C
(Combination of S and A, G, R, Y) 230/240V AC ±10% 24 • Enter the required
(15 × 30 mm) × 2 number of color
DC-DC Converter (PW, S) CDA 110V DC (90 txo 140V DC) 1 C screens in ( ).
Resistor (PW, S) RNA 100/110V AC/DC ±10% 1
One-color Full × 2 split 6V AC/DC ±10% (LFTD-6S) × 2 6
• Type F Spot
window (Type C)
(combination of PW, DPA 12V AC/DC ±10% (LFTD-1S) × 2 1 Illumination
LED Lamp

S only) 24V AC/DC ±10% (LFTD-2S) × 2 2 30 × 30 mm


SX6S/8 FST
Base 6
One-color Full × 2 split 6V AC/DC ±10% (LFTD-6∗)
window (Type C) DPC 12V AC/DC ±10% (LFTD-1∗) 1
(combination of PW,
S and A, G, R, Y) 24V AC/DC ±10% (LFTD-2∗) 2 Note 1: Type H2 (2-way split) can be configured with the
combination described below.
Left Right
Standard Clear Lens Standard Clear Lens
Color Screen Color Screen
Grey Lens Grey Lens

11
SLC30 Series Combination Display Lights

Ordering Information [Conversion Rate]


When ordering SLC Series Combination Display Lights, use the • Type H (horizontal)
specification sheet provided on page 36. Type F equivalent: 2 windows
Row (1), Column (2)
Designation Procedure
1. Part No.: Refer to Part No. Development Configuration on • Type L (horizontal)
page 12.
Type F equivalent: 3 windows
2. Quantity: Enter the required number of identical assemblies.
Row (1), Column (3)
Counting of Windows
Count the number of windows in the equivalent of Type F (basic • Type V (vertical)
size). Type F equivalent: 2 windows
Leaf Spring (for one-window type only) Row (2), Column (1)
Leaf spring for temporary fastening is not attached, and can be
supplied free of charge upon request when ordering (Part No. • Type G (large)
SLD44KVP). Type F equivalent: 4 windows
Row (2), Column (2)

• Type C (split-window)
Type F equivalent: 1 window
Row (1), Column (1)

[Designation Examples]
Ex. 1 SLC30 Series • When more than one color is
Units in one color required for LED.
Type F, 20 windows • When a particular arrangement of
color screen is required.

SLC30N- 04 05 F R (20) No entry is required in designations.

Columns Color screen: Type F, 20 windows Specify each color code on the
4 5 R (20) = 20 specification sheet.
2 3
1 Columns
Color Code
• When color screen is
1 Rows 1 2 3 4 5 6
Rows required, specify the color
2 screen code. R R R R R
1 +
3 Ex.
Color Code G G G G G +
4 2
Color Screen Code Y Y Y Y Y
3 +
Ex. 2 SLC30 Series 4
A A A A A +
Type H, 9 windows (Type F equivalent: 3 rows by 6 columns) 5 + + + + + +

SLC30N- 03 06 H R (9) No entry is required in designations.

Columns Color screen: Type H, 9 windows Specify each color code on the
R (9) = 9 specification sheet.
4 5 6
2 3 Columns
1 Color Code
• When color screen is
Rows 1 required, specify the color
Rows 1 2 3 4 5 6 7
2 screen code. PW R R +
1
3 Ex. PW R R
Color Code 2 +
Color Screen Code PW G G +
3
4 + + + + + + +

Ex. 3 SLC30 Series (Type F, 12 windows)


When ordering a combination of units with different operating voltages, specify Part No. as follows.
Type F, 12 windows, Full voltage type 24V AC/DC 8 Transformer Type 100/110V AC 4 Columns
Rows 1 2 3 4 5

1 + DD2
2 +
SLC30N-0304- DD 2 FB(8) + TD 1 FB(4) - R (12) 3 +
TD1

Specify the position of the units and each voltage on the specification sheet.

Columns
Ex. 4 When ordering a combination of units with different illumination colors, specify Part No. as follows. Color Code
Rows 1 2 3 4 5
PW R R R
Example: Full voltage 24V AC/DC, Red (6), Pure White (2) Specify the position of the units 1 +
and each color code on the PW R R R
2 +
SLC30N-0204-DD2FB(6) + DDA2FB(2) - R(6)PW(2) specification sheet.
+ + + + +
Red Pure White Designation
Red: 6, Pure White: 2
Columns
Ex. 5 When ordering a combination of units with different illumination colors for four windows of type C, Color Code

specify Part No. as follows.


Rows 1 2 3 4 5
R G
Example: Full voltage 24V AC/DC Specify the position of 1 PW PW + + +
S A
the units and each PW PW
2 + + +
SLC30N-0202-DPA2CB(1) DPC2CB(3) - R(1)G(1)A(1)S(1)PW(4) color code on the
+ + + + +
specification sheet.
Blue, Pure white Red, green, Designation
amber, pure white Red: 1, green: 1, blue 1,
amber 1, pure white 4

12
SLC40 Series Combination Display Lights
Highly bright “Super LED” unit improves visibility and safety.
• Eight types of illumination faces in 40mm size.
• Extensible window ensures high visibility An Example of 12-window size
when installed at high places (except C, L, G).
• Super bright Super LED. Spot illumination is
• The fingersafe spring-up terminals save available with type F only.
wiring time and prevent electrical shocks.
• The insulated jumper, when used on
fingersafe spring-up terminals, eliminates
the need of terminal cover.
• Legends can be engraved on the attached
marking plate. One or two thin marking
sheets (not attached) can also be installed
(Type F only).
• Spot illumination available for easy
recognition in bright environment (Type F only).
• UL and c-UL recognized, EN compliant
(*1)

1) Except for EN60947-5-1 DC-DC converter and resistor types.


See website for details.

Type F Type F Type C Type H Type L Type V Type G


(spot illumination)

A wide variety of illumination face sizes Extensible windows The Fingersafe Spring-up terminals
Type F: 40H × 40W mm (Basic size) Easy to recognize at high reduce wiring time.
Type F spot illumination: 40H × 40W mm places (except Type C, L, The integrated terminal cover and
Type C: 20H × 40W mm × 2 (Split-window type) and G) insulated jumpers prevent electic
shocks.
Type H: 40H × 80W mm
Type L: 40H × 120W mm Application Example of Jumpers
Type V: 80H × 40W mm
Type G: 80H × 80W mm
Combined construction is availble.

Type F Window Spot Illumination Kit


White Screen

24V AC/DC one-color Clear


full only. Marking
Plate
Spot illumination LED
unit is necessary.

Split-window reduces installation


Frame (metal) space.
The frame cover and frame are integrated
and molded of resin for Type F, Available up to 126 windows
one-window type. LED: 7 rows by 24 columns
LED illumination: 24V AC/DC
See page H-36 for details.
Columns
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

1
2
3
Rows
4
LED illumination 5
6
Maximum Number of
7
Windows for LED

• For 110/220V AC type, up to 60 windows (Type F equivalent) can be


LED Lamp
Spot Illumination mounted.
LED Unit (BA9S/13 base)
LED Unit For Type C only • For Type C, up to 105 windows (Type F equivalent) can be mounted.
• Lighting limitations should be considered in any applications.
For details, see page 29.

13
SLC40 Series Combination Display Lights

Configuration
Illumination Face
• See page 31 for the
combination of illumination
windows. Type F Type C Type H Type L Type V Type G

• Lens (acrylic) • Lens (acrylic)

• Marking Plate (acrylic)


(clear, white, color) • Marking Plate (acrylic)
(clear, white, color)
• Lens Frame (plastic)
• Lens Frame (plastic)

Type F, H, L, V, G
Marking Plate/Color Screen
Display Color Type Light Source Lens ON Color (Color Code) OFF Color
(one each) (Note 1) (Note 2)
Standard amber (A), blue (S), green (G), pure white (PW), red (R), yellow (Y),
clear / white White
(using clear lens) Clear red/green 2-color alternate (RG) (Note 1)
Lens Same as
Color Screen LED Unit color / white amber (TA), blue (TS), green (TG), red (TR), yellow (TY)
ON color
Gray amber (SA), blue (SS), green (SG), pure white (SPW),
Gray Lens black (Note 3) /clear Lens: gray Legend Color Gray
Lens red (SR), yellow (SY)
Note 1: Spot illumination is not available with red/green 2-color alternate (RG).
Note 2: The order to insert clear marking plate, color screen, and white screen can be interchanged if necessary.
Marking plate/color screen are interchangeable. Engrave markings on the flat surface of the plate or screen next to the lens.
Note 3: Black marking plate has black coating. Engrave a reverse legend on the black-coated surface.

Type C (split-window)
Marking Plate/Color Screen
Display Color Type Light Source Lens ON Color (Color Code) OFF Color
(one each) (Note 4)

Standard color / white Clear amber (A), blue (S), green (G), red (R), yellow (Y)
White
(using clear lens) clear / white Lens pure white (PW)
LED Lamp
black (Note 5) / color Gray amber (SA), blue (SS), green (SG), red (SR), yellow (SY)
Gray Lens Lens: gray Legend Color Gray
black (Note 5) / clear Lens pure white (SPW)
Note 4: The order to insert clear marking plate, color screen, and white screen can be interchanged if necessary.
Marking plate/color screen are interchangeable. Engrave markings on the flat surface of the plate or screen next to the lens.
Note 5: Black marking plate has black coating. Engrave a reverse legend on the black-coated surface.

Combination Example of 12 Windows


(V )

(H • Frame Cover
(H )
) Black (B)
(L )
• LED Unit for (F )
• LED Unit
Spot Illumination
(C

(C

• Mounting Clip
SLC-3K1
• LED Lamp (for Type C
(supplied)
only, BA9S/13 base)
(2 lamps for 1 window
equivalent to Type F)

One-color full One-color full One-color full Two-color Alternate


(w/check terminal) (Flasher)

24V AC/DC 24V DC (Except Type C) 24V DC (Type F only) 24V AC/DC (Except Type C)
One-color full One-color full One-color full

100/110V, 200/220V AC 100/110V DC (Resistor 110V DC (DC-DC Converter)


(Except Type C) Type) (Except Type C) (Except Type C)

• The illustration above shows combination examples of windows. One-window is available in Type F.

14
SLC40 Series Combination Display Lights

Specifications
Light Source LED Unit LED Lamp

Input Full Voltage Transformer DC-DC Converter Resistor Full Voltage

One-color Two-color One-color × 2


Illumination Flasher Type One-color One-color One-color
One-color w/check terminal (Note 1) Alternate Split-window Type (Type C)
Fingersafe Spring-up Provided —
(Note 2) Provided Provided
Terminal (except for check terminal) (Note 2)
100/110V AC
Rated Voltage 24V AC/DC ±10% 110V DC 100/110V AC/DC 24V AC/DC
24V AC/DC ±10% 24V DC ±10%
(AC: 50/60Hz) ±10% 200/220V AC (90 to 140V DC) ±10% ±10%
±10%
Maximum Current
Same as internal LED unit — 4.7 1.8 2.4 Same as internal LED lamp
Draw (VA)
Amber, blue, green, pure white, Red/green Amber, blue, green,
Illumination Color Amber, blue, green, pure white, red, yellow
red, yellow Alternate pure white, red, yellow
Standards UL, c-UL listed, EN compliant — —

Rated Voltage 24V AC/DC 24V AC/DC 24V AC/DC 24V AC/DC

Amber

Blue
Rated Current
(Note 6)

Pure White
Red: 15 mA
15 mA (Note 5) 15 mA 7 mA
Green: 15 mA
Built-in LED Unit/Lamp

Green

Red

Yellow
Amber (A), blue (S),
Illumination Amber (A), blue (S), green (G), Red (R)/ Amber (A), blue (S), green (G), pure white (PW),
green (G), pure white (PW),
Color (code) pure white (PW), red (R), yellow (Y) green (G) red (R), yellow (Y)
red (R), Y (yellow)
LED Life (reference) Approx. 50,000 hours (when used on complete DC, luminance reduces to 50% of the initial intensity)

Base Plug-in unit type (for SLC40 only) BA9S/13 base

Part No. SLCN-42M-∗ SLCN-42MW-RG SLCN-42M-∗ LSRD-2


1 LED lamp per window of
No. of Units 1 LED unit per window of basic Type F
basic Type F
Flashing Period
— 0.5 ±0.2s — —
(Note 3)
Insulation Resistance 100 MΩ (500V DC megger)
2000V AC (1 minute)
2000V AC (1 minute) 2500V AC (1 minute) 2000V AC
Dielectric Strength between live and dead
between live and dead parts between live and dead parts (1 minute)
parts
Operating Temperature (Note 4) –20 to +40°C –10 to +40°C –20 to +40°C –10 to +40°C –20 to +40°C –20 to +40°C

Storage Temperature –25 to +60°C (no freezing)

Operating Humidity 45 to 85% RH (no condensation)

Specify a color code in place of ∗.


Note 1: The rated voltage for w/check terminal is 24V DC only.
Note 2: Terminal cover is available (see page 23).
Note 3: Duty 1:1. Multiple flasher units do not synchronize with each other. Use Type F only.
Note 4: No freezing
Note 5: Spot illumination uses the spot illumination LED unit (SLCN-42ST-*). See page 26 for rated current.
Note 6: Rated current for LED lamp is for DC. See page 26 for AC.

Type F (Note 7) Type C


Illumination Face Type H Type L Type V Type G
(Basic) (Split-window)
Window (H × W) 40 × 40 20 × 40 40 × 80 40 × 120 80 × 40 80 × 80
Illumination Unit

Illumination Face (H × W) 37 × 37 17 × 37 37 × 77 37 × 117 77 × 37 77 × 77


Size (mm)

White color screen,


clear marking plate, 35.8 × 35.8 × 1.0 15.8 × 35.8 × 1.0 35.8 × 75.8 × 1.0 35.8 × 115.8 × 1.0 75.8 × 35.8 × 1.0 75.8 × 75.8 × 1.0
color screen (H × W × t)
Marking Film Applicable — — — — —
Engraving Area (white,
34 × 34 14 × 34 34 × 74 34 × 114 74 × 34 74 × 74
transparent, color plates)
Material of Marking Plate & Color Screen Acrylic

Lens Frame Color & Frame Cover Color Black (Munsell N1.5 equivalent)

Connection Wire Solid wire: ø1.6 × 2, Stranded 2 mm2 × 2

Terminal Screw M3.5 screw, Check terminal: M3

Degree of Protection IP40 (IEC60529)

Pollution Degree 3

Note 7: Flasher, one-window, pure white illumination, and spot illumination are available in Type F only.

15
SLC40 Series Combination Display Lights

Dimensions
[Front View] a: No. of Rows b: No. of Columns
Type F Type F Type H Type V
(Spot Illumination)
B = (40b + 16) B = (80b + 16) B = (40b + 16)
136
28 40 40 28 40 40 48 80 28 40 40
11 40

8.4
28
28

28
A = (40a + 16)

A = (40a + 16)
ø7
40

48
A = (80a + 16)
8.4
40
40

40

80
40
40

40

80
40 (SLC40N-0203-TDFSTB) 80

Type L Type G Type C B = (40b + 16)


B = (120b + 16) 28 40 40
B = (80b + 16)
68 120
48 80

20 20 18
A = (40a + 16)
28
A = (40a + 16)

48
A = (80 + 16)

80
40
40

80

20 20
40

120 40
80

All dimensions in mm.

Type F Dimensions & No. of Windows (Type C, H, L, V, and G can be converted into Type F.)
Columns b 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

Rows Dimensions B 56 96 136 176 216 256 296 336 376 416 456 496 536 576 616 656 696 736 776 816 856 896 936 976
Panel
Cut-out (D)
a A (45) (85) (125) (165) (205) (245) (285) (325) (365) (405) (445) (485) (525) (565) (605) (645) (685) (725) (765) (805) (845) (885) (925) (965)
(C)

01 56 (45) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
02 96 (85) 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48
03 136 (125) 3 6 9 12 15 18 21 24 27 30 33 36 39 42 45 48 51 54 57 60 63 66 69 72
04 176 (165) 4 8 12 16 20 24 28 32 36 40 44 48 52 56 60 64 68 72 76 80 84 88 92 96
05 216 (205) 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120
06 256 (245) 6 12 18 24 30 36 42 48 54 60 66 72 78 84 90 96 102 108 114 120 — — — —
07 296 (285) 7 14 21 28 35 42 49 56 63 70 77 84 91 98 105 112 119 126 — — — — — —

Panel Cut-out (SLC40)


How to Read the Table
1. The number of windows equals rows multiplied by columns. For example, for 5 rows by D
7 columns, the number of windows is 35, external dimensions are 216mm high by 296mm Determine the panel
wide, and panel cut-out is 205mm high by 285mm wide. thickness in consideration of
2. External dimensions are represented by A for rows and B for columns in boldface. the weight of display lights
C

and wires (see page 23).


3. Panel cut-out dimensions are shown in ( ), for height (C) and width (D). Panel cut-out
tolerance is +1.0 to –0 mm (for one window: +0.6 to –0.4mm).

4. Total number of windows, dimensions, panel cut-out • Type L — Type F equivalent: 3 windows
➀ For Type C, H, L, V, and G, convert the numbers of rows Height: 1 row
and columns into Type F (basic size) equivalents. Width: 3 columns
L V 1
V • Type C — Type F equivalent: 2 split-windows consist
F • Type G — Type F equivalent: 4 windows
F 2 of one window.
F
F Height: 2 rows
F H 3 Width: 2 columns
H
H
5
6 • Type H — Type F equivalent: 2 windows
4 Height: 1 row
3
2 Width: 2 columns
1

• Type V — Type F equivalent: 2 windows.


Height: 2 rows
Width: 1 column

➁ The combination example at left consists of 3 rows by 6 columns.


➂ The above table shows: No. of windows: 18
Dimensions: 136H × 256W mm
Panel cut-out: 125H × 245W mm

16
SLC40 Series Combination Display Lights

Dimensions
[Side & Rear Views]
• Full Voltage • Full Voltage • Full Voltage
• 24V AC/DC • One-color full • One-color full
• One-color full • w/Check Terminal 24V DC • Flasher 24V DC (Type F only)
• For applicable terminal cover, see page 23. • Two-color alternate 24V AC/DC • For applicable terminal cover, see page
• Spot illumination 24V AC/DC • For applicable terminal cover, see page 23. 23.

40 40 40
6

Panel Thickenss
Panel Thickness
Panel Thickness

87.5
69.9

73

0.8 to 6
0.8 to 6
0.8 to 6

40
M3 Check Terminal 11 M3.5 Terminal Screws
40 M3.5
Terminal Screws 8.3 5.5 40 M3.5 Terminal Screws
11
X1 X1

19
40
X1 X1 X2 X2

C C
X1 X1
19
19

X1 X1
40

X2 X2
X2 X2
X2 X2
40

X1 X1
C C
X1 X1

X2 X2
X2 X2

• w/Check Terminal • Terminals X1 and X2 are positive


Terminal X1 is a positive pole; Terminal X2 and negative poles, respectively.
and C (check terminal) are negative poles.
• Two-color Alternate
Terminal X1 is common.
Red (R) illumination: Terminal C
Green (G) illumination: Terminal X2

• Transformer • Resistor Type C (split-window)


• One-color full • One-color full • Full Voltage
• 100/110, 200/220V AC • 100/110V AC/DC • 24V AC/DC
• 110VDC (DC-DC Converter) • One-color full, 2 × LED
lamps,
Split-window
40 40
6

6
6
Panel Thickness
Panel Thickness

Panel Thickness
87.5

66.5
0.8 to 6
87.5

SLC-3K1
0.8 to 6

0.8 to 6

40 M3.5
9.2

40
M3.5 11 Terminal Screws
11 Terminal Screws
20

X1 X1 X1
19

X1 X1 X2 X2 X2
40
19

X2 X2
40

X1 X1 X1
40

X1 X1 X2 X2 X2

X2 X2

40 11
M3.5 Terminal Screws
• On DC-DC Converter type units, • Terminal X1 is COM terminal.
Terminals X1 and X2 are positive and • For applicable terminal cover, see page 23.
negative poles, respectively.

All dimensions in mm.

17
SLC40 Series Combination Display Lights

Dimensions
All dimensions in mm.
[One-window, Type F only]
Full Voltage 24V AC/DC, One-color Full Spot Illumination
Panel Thickness 0.8 to 6 Mounting Clip SLC-3K1
Panel Cut-out
M3.5 Terminal Screws 11 +0.6
45 –0.4

8.4

40
40

+0.6
11

–0.4
45
56 6 69.9 19 56

Full Voltage 24V DC, w/Check Terminal


Two-color Alternate 24V AC/DC
Mounting Clip SLC-3K1 • w/Check Terminal Type
Panel Thickness 0.8 to 6 M3.5 Terminal Screws
Terminal X1 is a positive pole; Terminals X2 and C
(check terminal) are negative poles.
M3 Check Terminal
• Two-color Alternate Type
Red (R) illumination: X1 positive, C positive
Green (G) illumination: X1 positive, X2 positive
• See page 23 for terminal covers.
40

13.8

56 6 73 19

Flasher 24V DC
Transformer 100/110, 200/220V AC
DC-DC Converter 110V DC
Resistor 100/110V AC/DC
Panel Thickness 0.8 to 6 Mounting Clip SLC-3K1 • On flasher type, Terminals X1 and X2 are positive and
negative poles, respectively.
M3.5 Terminal Screws
• On DC-DC converter type, Terminals X1 and X2 are
positive and negative poles, respectively.
• Resistance
7.2 kΩ, 4W
40

11

56 6 87.5 19

[Two-window, Type C only]


Panel Thickness 0.8 to 6 Mounting Clip SLC-3K1
20 20 M3.5 Terminal Screws
56

40

11

18 20 6 68.1 20

18
SLC40 Series Combination Display Lights

Terminal Connection) Terminal Connection Using Jumpers


• For check terminal, DC-DC converter, and resistor, Terminals X1 • For terminal connection of types F, H, L, V, and G (except Type C)
and X2 are positive and negative poles, respectively. using jumpers, jumpers can be used as shown below.
SLC40 Series
Terminal X1 Terminal X2 Terminal C

Fingersafe,
Arrows indicate SLCN-JP44 SLCN-JP44
Spring-up Terminal —
access direction for SLCN-JP45 SLCN-JP45
(Note 1)
wiring terminals.
Others SLC-JP40 SLC-JP41 SLC-JP42
Note 1: Fingersafe, spring-up terminals are used in one-color full
Fingersafe, Spring-up Other terminals illuminated (12, 24V AC/DC, 100/110, 200/220V AC, 110V DC).
Terminal • For Type C, jumpers can be used on Terminal X1 only as shown
below.
(Flasher Connection Diagram)
• When using Type C only
Direction
• When using Type C and Two-color alternate
X1
Positive LED Module Vertical SLC-JP40
Flasher Horizontal SLC-JP41
Circuit
Note: Jumpers cannot be used when using Type C and fingersafe spring-
Negative up terminals.
X2

• For w/check terminal and two-color alternate units, Terminal X1


[Examples of Using Jumpers]
Fingersafe Spring-up Terminal
is a positive pole; Terminals X2 and C (check terminal) are nega-
tive poles. For two-color alternate, Terminal X1 is common. When using two windows
Using one SLCN-JP45 jumper
Arrows indicate access directions for
X1 wiring terminals.
C (w/Check Terminal Connection Diagram)

X1
Positive
X2
C
LED When using three windows
Negative Using two SLCN-JP45 jumpers
Module
X2
Negative

• Connection for Two-color alternate is as follows.


Terminal X1 (+) is common (AC/DC).
Red (R):Terminal C, Green (G):Terminal X2 When using four windows
Using one SLCN-JP44 jumper
(Two-color alternate Connection Diagram)
X1
Common
Positive

C
Red (R)
Negative LED Module

X2 Jumpers (SLCN-JP44/45) have an orientation.


LED Module
Negative
Green (G) Ensure that jumpers are installed correctly.
Flasher
Circuit
• For the split-window (Type C), Terminal X1 (+) is a common Correct Incorrect
terminal. Terminal X2 is for upper illumination and Terminal X3 is
for lower illumination (AC/DC).
Arrows indicate access direction
for wiring terminals.
(Type C Split-window Connection Diagram)

X1 Common
X2 X1
X3 LSRD
X2 Upper

LSRD
X3 Lower

Recommended tightening torque:


M3.5: 1 to 1.3 N·m
M3: 0.6 to 1.0 N·m

19
SLC40 Series Combination Display Lights

Part No. Development


SLC40N – 0 4 0 5 – TD 2 F B – Example: A (10), G (5), R (5)
Specify the color code and the number of windows.

40 Series When ordering Type H, L, Frame Color


V, G, or C units, enter the Black: B
equivalents of Type F.

Equivalent of Operating Voltage Illumination Face Size Illumination


Basic Size Unit (Code) Color
(Built-in Lamp) (Code)
Windows
12V AC/DC ±10% 1 • Clear Lens
Rows Columns Full Voltage (A, G, R, Y) DD Combination (Code)
01 01 24V AC/DC ±10% 2 • Type F
F Amber A
Full Voltage (PW, S) DDA 24V AC/DC ±10% 2 40 × 40 mm
02 02
Full Voltage w/Check Terminal Green G
03 03 (A, G, R, Y) DHM 24V DC ±10% 2
Pure White PW
04 04 Full Voltage Two-color Alternate
DW 24V AC/DC ±10% 2 Red R
(R/G)
LED Unit

05 05 • Type H
Full Voltage Flasher (A, G, R, Y) DF 24V DC ±10% 2 H Blue S
40 × 80 mm
06 06 100/110V AC ±10% 1 Yellow Y
07 07 Transformer (A, G, R, Y) TD
200/220V AC ±10% 2 Red/Green RG
08 100/110V AC ±10% 1
09 Transformer (PW, S) TDA • Type L
200/220V AC ±10% 2 L • Color Screen
40 × 120 mm
10 DC-DC Converter (A, G, R, Y) CD 110V DC (90 to 140V DC) 1
Combination
(Code)
11 Resistor (A, G, R, Y) RN 100/110V AC/DC ±10% 1 When color display is
12 One-color Full × 2 split required at power off,
BA9S/13
Lamp
LED

window (Type C) (A, G, Base DP 24V AC/DC ±10% (LSRD-2) 2 order color screens. For
13 R, Y) • Type V details, see page 31.
14 V
80 × 40 mm
Amber TA
15
The following color/voltage selections are also available. Green TG
16
Operating Voltage (Built-in Lamp) Red TR
17 Unit
(Code)
Blue TS
18 Full Voltage w/Check Terminal DHMA 24V DC ±10% 2 Yellow TY
(PW, S) • Type V
19 G
Full Voltage Flasher DFA 24V AC/DC ±10% 2 80 × 80 mm • Gray Lens Combination
20 (PW, S) (Code)
21 115V AC ±10% 11 Amber SA
22 120V AC ±10% 12 Green SG
23 230V AC ±10% 23 Pure White SPW
• Type C
24 Transformer (A, G, R, Y) TD 240V AC ±10% 24 C
(20 × 40 mm) × 2 Red SR
380V AC ±10% 38 Blue SS
400/440V AC ±10% 4 Yellow SY
LED Unit

480V AC ±10% 48 • Type F Spot • Type H, L, V, and


115V AC ±10% 11 Illumination FST G cannot be split-
40 × 40mm illuminated.
120V AC ±10% 12 • Enter the required
230V AC ±10% 23 number of color
screens in ( ).
Transformer (PW, S) TDA 240V AC ±10% 24
380V AC ±10% 38
400/440V AC ±10% 4
480V AC ±10% 48
DC-DC Converter (PW, S) CDA 110V DC (90 to 140V DC) 1
Resistor (PW, S) RNA 100/110V AC/DC ±10% 1
One-color Full window
(Type C)
(combination of PW, S DPA 24V AC/DC ±10% (LSRD-2) × 2 2
LED Lamp

only) BA9S/13
One-color Full window Base
(Type C)
DPC 24V AC/DC ±10% (LSRD-2) 2
(combination of PW,
S and A, G, R, Y)

20
SLC40 Series Combination Display Lights

Ordering Information [Conversion Rate]


When ordering SLC Series Combination Display Lights, use the • Type H (horizontal)
specification sheet provided on page 36. Type F equivalent: 2 windows
Row (1), Column (2)
Designation Procedure
• Type L (horizontal)
1. Part No.: Refer to Part No. Development on page 21.
Type F equivalent: 3 windows
2. Quantity: Enter the required number of identical assemblies. Row (1), Column (3)
Counting of Windows
Count the number of windows in the equivalent of Type F (basic • Type V (vertical)
size). Type F equivalent: 2 windows
Leaf Springs Row (2), Column (1)
Leaf spring for temporary fastening is not attached, and can be • Type G (large)
supplied free of charge upon request when ordering (Part No. Type F equivalent: 4 windows
SLD40KVP). Row (2), Column (2)

• Type C (split-window)
Type F equivalent: 1 window
Row (1), Column (1)
[Designation Examples]
Ex. 1 SLC40 Series LED illuminated units • When more than one color is
in one color. required for LED.
Type F, 20 windows • When a particular arrangement of
color screen is required.

SLC40N- 04 05 F B R (20) No entry is required in designations.

Columns Color screen: Type F, 20 windows Specify each color code on the
4 5 R (20) = 20 specification sheet.
2 3
1 Columns
Color Code
• When color screen is
1 Rows 1 2 3 4 5 6
Rows required, specify the color
2 screen code. R R G G G
1 +
3 Ex.
Color Code Y Y Y Y Y +
4 2
Color Screen Code A A S S S
3 +
Ex. 2 SLC40 Series 4
A A S S S +
Type H, 9 windows (Type F equivalent: 3 rows by 6 columns) 5 + + + + + +

SLC40N- 03 06 H B G (9) No entry is required in designations.

Columns Color screen: Type H, 9 windows Specify each color code on the
G (9) = 9 specification sheet.
4 5 6
2 3 Columns
1 Color Code
• When color screen is
1 2 3 4 5 6 7
Rows 1 required, specify the color
Rows

2 screen code. PW R R +
1
3 Ex. PW R R
Color Code 2 +
Color Screen Code PW G G +
3
4 + + + + + + +
Ex. 3 SLC40 Series (Type F, 12 windows)
When ordering a combination of units with different operating voltages, specify Part No. as follows.
Type F, 12 windows, Full voltage 24V AC/DC 8 Transformer 100/110V AC 4 Columns
Rows 1 2 3 4 5

1 + DD2
2 +
SLC40N-0304- DD 2 FB(8) + TD 1 FB(4) - R(12) 3 +
TD1
+ + + + +
4
Specify the position of the units and each voltage on the specification sheet.

Ex. 4 When ordering a combination of units with different illumination colors, specify Part No. as follows.
Rows

Columns
Example: Full voltage LED illuminated 24V AC/DC, Red (6), Pure White (2) Specify the position of the units Color Code
and each color code on the 1 2 3 4 5
SLC40N-0204-DD2FB(6) + DDA2FB(2) - R(6)PW(2) specification sheet. PW R R R
+
1
Red Pure White Designation 2
PW R R R
+
Red: 6, Pure White: 2
+ + + + +

Columns
Ex. 5 When ordering a combination of units with different illumination colors for four windows of type C, Color Code

specify Part No. as follows.


Rows 1 2 3 4 5
R G
Example: Full voltage LED illuminated 24V AC/DC Specify the position of 1 PW PW + + +
S A
the units and each PW PW
2 + + +
SLC40N-0202-DPA2CB(1) DPC2CB(3) - R(1)G(1)A(1)S(1)PW(4) color code on the
+ + + + +
specification sheet.
Blue, Pure white Red, green, Designation
amber, pure white Red: 1, green: 1, blue 1,
amber 1, pure white 4

21
SLC30/40 Series Combination Display Lights Accessories

Terminal Cover

Ordering Terminal Covers


• The fingersafe, spring-up terminal types have integral covers, and do not require terminal covers.
• Terminals other than fingersafe, spring-up terminals do not have terminal covers and need covers ordered separately.

Applicable Terminal Covers (Material: PPE)

SLC30-VL5 SLC40-VL5 SLC30-VL6 SLC40-VL6 When using a terminal


cover, the depth is
extended shown as
below.
Series Style

Terminal Cover

29H × 28W 36H × 33.5W 29H × 26W 39H × 28W


zzzzzzzzzOne-color Full
Applicable +5.7 mm
w/Check Terminal

SLC30 Two-color Alternate Applicable +5.7 mm

Type C (half-type)
Applicable +2.5 mm
one color Full × 2
One-color Full
Applicable +4.7 mm
w/Check Terminal

SLC40 Two-color Alternate Applicable +4.7 mm

Type C (half-type)
Applicable +3 mm
one color Full × 2

Weight
Approximate weight of SLC combination display lights can be calculated in the formula below.
Weight = A × (No. of Rows + No. of Columns) + B × No. of Windows
Type F equivalent Type F equivalent
Frame Weight Display Weight

B (including light source)

(Full Voltage) (Resistor)


Series A (Transformer) Type C
6V AC/DC (Full Voltage) 100/110V DC (DC-DC Converter)
100/110V AC Split-window
12V AC/DC Flasher 100/110V AC/DC 110V DC
200/220V AC (Type F equivalent)
24V AC/DC (Note 2)

SLC30 (Approx.) 22g 38g 48g 85g 47g 54g 46g

SLC40 (Approx.) 30g 60g 71g 126g 69g 77g 66g

22
SLC30/40 Series Combination Display Lights Accessories

Accessories / Replacement Parts


Accessories
Applicable Package
Name & Shape Part No. Ordering No. Remarks
Model Quantity
Spot Illumination Kit for Type F Window
White Plate SLC30N SLCN-3ST-F2 SLCN-3ST-F2 1 Lens Spot Light Lens White Plate

Clear Plate
SLC40N SLCN-4ST-F2 SLCN-4ST-F2 1
(supplied with the spot illumination type SLC)
Lens Frame Clear Plate
SLC30N SLDN-3C-FW-ST1 SLDN-3C-FW-ST1 1
White Screen for Spot Illumination Matte Surface
SLC40N SLDN-4PF-FW-ST1 SLDN-4PF-FW-ST1 1

Tool Accessories
Package
Name & Shape Material Part No. Ordering No. Remarks
Quantity
Lamp Holder Tool Used for replacing LED lamps (LFTD) for SLC30
ø6.6
Type C (Split-window).
Rubber OR-44 OR-44 1
ø7.5
60

Lamp Holder Tool Used for replacing LED lamps.

ø11.6

ø14
Rubber OR-55 OR-55 1
59

LED Unit Removal Tool Used for removing the LED unit for the SLC30/40
series.
Metal MT-101 MT-101 1
60

Lens Unit Removal Tool Used for removing the lens unit.

Rubber
MT-S01 MT-S01 1
(Ring: metal)

Marking Plate, Color Screens


Applicable Package
Name & Shape Series Dimensions (mm) Part No. Ordering No. Color Code
Window Quantity
Color Screen F 27H × 27W × 1.0t SLDN-3C-∗ SLDN-3C-∗PN05
H and V 27H × 57W × 1.0t SLC-3PH-∗ SLC-3PH-∗PN05
H (split-window) 27H × 28.5W × 1.0t SLC-3PH2-∗ SLC-3PH2-∗PN05
SLC30 A: Amber
L 27H × 87W × 1.0t SLC-3PL-∗ SLC-3PL-∗PN05
C: Clear (clear screen)
G 57H × 57W × 1.0t SLC-3PG-∗ SLC-3PG-∗PN05 FW: White (white screen)
G: Green
C 12H × 27W × 1.0t SLC-3PC-∗ SLC-3PC-∗PN05 5
R: Red (Type F)
F 35.8H × 35.8W × 1.0t SLCN-4PF-∗ SLCN-4PF-∗PN05 RL: Red (Except Type F)
S: Blue
H and V 75.8H × 35.8W × 1.0t SLC-4PH-∗ SLC-4PH-∗PN05
Y: Yellow
SLC40 L 35.8H × 115.8W × 1.0t SLC-4PL-∗ SLC-4PL-∗PN05
G 75.8H × 75.8W × 1.0t SLC-4PG-∗ SLC-4PG-∗PN05
C 15.8H × 35.8W × 1.0t SLC-4PC-∗ SLC-4PC-∗PN05
Acrylic
Black Marking Plate F 27H × 27W × 1.0t SLDN-3C-WM SLDN-3C-WM
H and V 27H × 57W × 1.0t SLC-3PH-FWM SLC-3PH-FWM
H (split-window) 27H × 28.5W × 1.0t SLC-3PH2-FWM SLC-3PH2-FWM
SLC30
L 27H × 87W × 1.0t SLC-3PL-FWM SLC-3PL-FWM
G 57H × 57W × 1.0t SLC-3PG-FWM SLC-3PG-FWM
C 12H × 27W × 1.0t SLC-3PC-FWM SLC-3PC-FWM — 1
Black-
coated F 35.8H × 35.8W × 1.0t SLCN-4PF-FWM SLCN-4PF-FWM
H and V 75.8H × 35.8W × 1.0t SLC-4PH-FWM SLC-4PH-FWM
SLC40 L 35.8H × 115.8W × 1.0t SLC-4PL-FWM SLC-4PL-FWM
G 75.8H × 75.8W × 1.0t SLC-4PG-FWM SLC-4PG-FWM
C 15.8H × 35.8W × 1.0t SLC-4PC-FWM SLC-4PC-FWM

Note: For insertion order into SLC frames or markings, see operating instructions on page 31 and 32.

23
SLC30/40 Series Combination Display Lights Accessories

Replacement Parts
Lens
Name & Shape Description Series Applicable Window Dimensions (mm) Material Part No.
F 28H × 28W × 2.8t SLC-3LF
H and V 28H × 58W × 2.8t SLC-3LH
SLC30 L 28H × 88W × 2.8t SLC-3LL
G 58H × 58W × 2.8t SLC-3LG
C 13H × 28W × 2.8t SLC-3LC
Clear
F 36.8H × 36.8W × 2.8t SLC-4LF
H and V 36.8H × 76.8W × 2.8t SLC-4LH
SLC40 L 36.8H × 116.8W × 2.8t SLC-4LL
G 76.8H × 76.8W × 2.8t SLC-4LG
C 16.8H × 36.8W × 2.8t SLC-4LC
Acrylic
F 28H × 28W × 2.8t SLC-3LF-M
H and V 28H × 58W × 2.8t SLC-3LH-M
SLC30 L 28H × 88W × 2.8t SLC-3LL-M
G 58H × 58W × 2.8t SLC-3LG-M
C 13H × 28W × 2.8t SLC-3LC-M
Gray
F 36.8H × 36.8W × 2.8t SLC-4LF-M
H and V 36.8H × 76.8W × 2.8t SLC-4LH-M
SLC40 L 36.8H × 116.8W × 2.8t SLC-4LL-M
G 76.8H × 76.8W × 2.8t SLC-4LG-M
C 16.8H × 36.8W × 2.8t SLC-4LC-M

Lens Frame
Shape Series Applicable Window Material Part No.
F SLC-3WF-BL
H ABS SLC-3WH-BL
H (split-window) (Note) SLC-3WH2-BL
SLC30 L PC SLC-3WL-BL
V SLC-3WV-BL
G SLC-3WG-BL
C ABS SLC-3WC-BL
F SLC-4WF-BL
H SLC-4WH-BL
L PC SLC-4WL-BL
SLC40
V SLC-4WV-BL
G ABS SLC-4WG-BL
C SLC-4WC-BL

Note: A light barrier is supplied.

LED Units
Operating
Series & Shape Illumination Rated Current Part No. Ordering No. Color Code
Voltage
SLC30
6V AC/DC Amber, green, red, yellow:12mA SLDN-36M-∗ SLDN-36M-∗T

One color
12V AC/DC Amber, green, red, yellow: 12mA SLDN-31M-∗ SLDN-31M-∗T
full
Specify a color
Amber, red: 12mA code in place
24V AC/DC SLDN-32M-∗ SLDN-32M-∗T of ∗ in the Part
Blue, green, pure white, yellow: 11mA
No.
Two-color
alternate
24V DC Red: 12mA/green: 11mA SLDN-32MW-RG SLDN-32MW-RGT A (amber)
Weight: approx. 4.3g
G (green)
SLC40 PW (pure
One color Amber, blue, green, pure white, red, white)
24V AC/DC SLCN-42M-∗ SLCN-42M-∗T R (red)
full yellow: 15mA
S (blue)
Y (yellow)

Two-color
alternate
24V AC/DC Red: 15mA/green: 15mA SLCN-42MW-RG SLCN-42MW-RGT
Weight: approx. 9.2g

Note: Blue (S) and PW (pure white) are 24V AC/DC only

24
SLC30/40 Series Combination Display Lights Accessories

Replacement Parts
LED Units for Spot Illumination
Rated Voltage
Series & Shape Rated Current Part No. Ordering No. Color Code
(AC: 50/60 Hz)
SLC30

Amber, red: 12mA


24V AC/DC Blue, green, pure white, yellow: SLDN-32ST-* SLDN-32ST-*T Specify a color
11mA code in place of ∗ in
the Part No.
Weight: approx. 4.5g
A (amber)
SLC40 G (green)
PW (pure white)
R (red)
Amber, blue, green, pure white, red, S (blue)
24V AC/DC
yellow: 15mA SLCN-42ST-* SLCN-42ST-*T Y (yellow)

Weight: approx. 9.4g

• Used with SLCN-ST-* spot illumination kit. The spot color is same as illumination surface.

LED Lamps
Operating Current Draw Illumination Package
Shape Part No. Ordering No. Base
Voltage DC Rating AC Rating Color Quantity
LFTD Lamp (SLC30) LFTD-5∗ 1
8 mA (except S)
5V DC — LFTD-5∗
7 mA (S) LFTD-5∗PN10 10
Specify a color code in
9 mA 1
7 mA (except S) LFTD-6∗ place of ∗ in the Part
6V AC/DC (A, R, S, Y) LFTD-6∗
6 mA (S) No.
10 mA (G, PW) LFTD-6∗PN10 A (amber) 10 SX6S/8
G (green) 1 × 5.4
8 mA (except S) 9 mA (except S) LFTD-1∗
12V AC/DC LFTD-1∗ PW (pure white)
ø6.2

14.5
7 mA (S) 8 mA (S) LFTD-1∗PN10 R (red) 10
S (blue)
8 mA (except S) 9 mA (except S) LFTD-2∗ 1
24V AC/DC LFTD-2∗
7 mA (S) 8 mA (S) LFTD-2∗PN10 10
LSRD Lamp (SLC40)

LSRD-2 1

24V AC/DC 7mA 8mA LSRD-2 — BA9S/13

LSRD-2PN10 10

• Only one color is available for LSRD so there are no codes to specify the color in the part no.

25
SLC30/40 Series Combination Display Lights Accessories

Accessories / Replacement Parts


Full Voltage Adapter
Shape Series Description Part No.

SLC30 SLDN-3DH

One-color Full

SLC40 SLDN-4DH

Transformer Unit
Primary Voltage
Shape Series Illumination Applicable LED Unit Part No.
(50/60 Hz)

100/110V AC SLDN-3TH1
SLC30 SLDN-32M-*
200/220V AC SLDN-3TH2
LED
100/110V AC SLDN-4TH1
SLC40 SLCN-42M-*
200/220V AC SLDN-4TH2

Separate Transformer (24V output, LED Unit)


Applicable
Shape
Primary Secondary
Part No. LED Unit/
Dimensions
Voltage Voltage
Lamp
M3.5 Terminal Screws
100/110V AC 0.5W, 24V TWR512
See the

SEC. 4

2
200/220V AC 0.5W, 24V TWR522 table

JAPAN

PRI.

22
30
Secondary Side Primary
below. Side

1
400/440V AC 0.5W, 24V TWR542
Mounting Hole 40
2-ø3.3 48
• Terminal cover (Part No. TWR-VL3) is supplied as standard.
52

Applicable LED Unit/Lamp


Terminal
Series LED Part No. Applicable Model Cover
41
40

45.5
SLDN-32M-∗ One-color full (one unit per transformer)
LED Unit
5

Two-color alternate (one unit per


SLC30 SLDN-32MW-RG
transformer) BAA1000

LED Lamp LFTD-2∗ Type C (up to two lamps per transformer)


SLCN-42M-∗ One-color full (one unit per transformer) All dimensions in mm.
LED Unit Two-color alternate (one unit per
SLC40 SLCN-42MW-RG
transformer)
LED Lamp LSRD-2 Type C (one unit per transformer)

• Specify a color code in place of ∗. See page 26.

26
SLC30/40 Series Combination Display Lights Accessories

Accessories / Replacement Parts


Package
Name & Shape Part No. Ordering No. Description & Dimensions
Quantity
Ring Terminal (for four windows) ø4.4 4.9
Rated Current: 3A L 3.2
For SLC30
SLCN-JP34 SLCN-JP34PN10
Terminal X1, X2

11.6
A A A t = 0.5

Part No. L A
For SLC40
SLCN-JP44 SLCN-JP44PN10 SLCN-JP34 97.8 30
Jumper for Terminal X1, X2
fingersafe, SLCN-JP44 128 40
(Supplied)
Spring-up
Terminal Ring Terminal (for 2 windows) ø4.4
4.9
Rated Current: 3A L 3.2
For SLC30
SLCN-JP35 SLCN-JP35PN10
Terminal X1, X2

11.6
A t = 0.5

Part No. L A
For SLC40
SLCN-JP45 SLCN-JP45PN10 SLCN-JP35 37.8 30
Terminal X1, X2
SLCN-JP45 48 40
(Supplied)
Spade Terminal
L
Rated Current: 3A
For SLC30 A
SLC-JP30 SLC-JP30PN10
Terminal X1

7.7
4 t = 0.5

Part No. L A±0.1


For SLC40
SLC-JP40 SLC-JP40PN10 SLCN-JP30 38 30
Terminal X1
SLCN-JP40 48 40
(Supplied) 10
Ring Terminal 37.8 3
Rated Current: 3A For SLC30
Terminal X2 or
10.7
SLC-JP33 SLC-JP33PN10
Terminal X1 of
Jumper for Type C 30
t = 0.5
ø4.4
Other
Terminals 3
48
For SLC40
SLC-JP41 SLC-JP41PN10
10.9

Terminal X2
40
t = 0.5
ø4.4
Ring Terminal L
Rated Current: 3A For SLC30 ø3.8
Terminal C (check A
SLC-JP32 SLC-JP32PN10
terminal & 2-color
alternate)
6

t = 0.5
B

For SLC40 Part No. L A±0.1 B


Terminal C (check
SLC-JP42 SLC-JP42PN10 SLCN-JP32 37 30 2.5
terminal & 2-color
alternate) SLCN-JP42 47 40 2.5

Mounting Clips
36 2
Used for fastening SLC
10

units to panel cut-out


SLC-3K1 SLC-3K1PN10 from the rear of the 1.2
23
panel.
Weight: approx. 4.6g
6.8

M3
(Supplied)

All dimensions in mm.


Jumper Application Examples
On Fingersafe, Spring-up Terminals On Other Terminals Spade Terminal
(for Terminal X1)
Jumper
Ring Terminal
(for Terminal C)
Ring Terminal
(for Terminal X2)

27
SLC30/40 Series Combination Display Lights Instructions

Safety Precautions
• Turn off the power to the SLC units before installation, removal, • For wiring, use wires of a proper size to meet the voltage and
wiring, maintenance, or inspection. Before removing the LED current requirements and tighten the terminal screws to the
units, make sure that power is turned off. Failure to turn off the tightening torque shown below. Loose terminal screws may
power may cause an electrical shock, create fire hazards, or cause excessive heating, resulting in fire hazards.
damage of LED units or lamps. Do not use the SLC units without • Do not install or operate the SLC units where the SLC units are
the lens, otherwise ingress of foreign objects may cause short subjected to direct sunlight. Excessive heating may create fire
circuit, and LED units may be damaged resulting in the deterio- hazards or damage the SLC units.
ration of LED brightness or no lighting.
• When replacing LED units or LED lamps, use IDEC products.
• When lighting the SLC units continuously, observe the condi-
tions described below. If the limits are exceeded, the SLC units
may heat up and create fie hazards or damage the SLC units.

Operating Instructions
Notes for Continuous Lighting <Storage and Handling>
Up to 10 SLC units (Type F equivalent) can be lit continuously. • Do not use the SLC where it is subjected to condensa­tion
When more units are mounted, consider the following restrictions. caused by extreme temperature change.
Full voltage • Do not use chemicals such as alcohol that degrade the property
of acrylic.
• Do not light more than 40% of the SLC units continuously, and
light the units in a checker pattern.
• When more than 40% of the units are lit continuously, limit the <Operating Instructions>
lighting duration to 40 minutes. Before lighting the units again, • The illumination color may change depending on the decreasing
ensure that all units have cooled down. brightness of LED, along with the period of use.
• When using 2-color alternate units, do not light the two colors • The SLC can be used indoors only. Do not use outdoors.
simultaneously.
Transformer and DC-DC converter
• Light the units in a flashing or checker pattern.
When using the SLC units in other conditions, contact IDEC.

Notes for Panel Mounting


• When mounting the SLC units on a panel, determine the panel
thick­ness taking the weights of the SLC units and wires into
consideration.

Tightening Torque for Terminal Screws


• For wiring, use wires of a proper size to meet the voltage and
current requirements and tighten the terminal screws to the
tightening torque shown below.
Terminal Screw Tightening Torque
M3 0.6 to 1.0
M3.5 1.0 to 1.3 N·m
M4 1.4 to 2.0 N·m

28
SLC30/40 Series Combination Display Lights Instructions

Operating Instructions
When Using Blue and Green LED Units Notes for Using LED Units
When replacing LED units, avoid ESD to the LED pins, otherwise Countermeasures against dim lighting
the internal LED elements may become damaged. The SLC units contain a provision against dim lighting due to leak­
age current. If the LED unit appears to be dimly lit due to induced
Metal Pins current from nearby AC lines, take appropriate countermeasures
as described below.
[Sample Circuit]
AC Line

~ ~ Transformer
C
Type LED
R
Ie

Protection
Precautions for Noise Ie: Induced Current
Circuit

When using the SLC units in an environment where the SLC is


sub­jected to noise, connect a noise suppressor across terminals [Countermeasure]
X1 and X2 as shown below. As shown in the diagram above, connect an RC circuit in parallel
Noise Suppressor with the transformer LED unit. For the values of the resistor and
capacitor, see the following table.
X2 Capacitor C Resistor R
Operating Voltage
(µF) (Ω) (W)
X1 100/110V AC (50/60 Hz) 0.33 120 0.25
SLC30
200/220V AC (50/60 Hz) 0.10 120 0.25
100/110V AC (50/60 Hz) 0.22 120 0.25
SLC40
200/220V AC (50/60 Hz) 0.10 120 0.25

LED Unit Internal Circuit X1 X1 X1

SLC30 Series
• SLDN-36M-∗ (6V AC/DC) •X2
SLDN-36M-W (6V AC/DC) • S X2
 LDN-31M-W (12V AC/DC) X2

• SLDN-31M-∗ (12V AC/DC) One-color full (white) One-color full (white)


One-color full
(amber, green, red, yellow) LED Chip
Rectifying Diode
X1 X1 Zener Diode
X1X1 X1 X1
X1X1
X1 X1 X1 X1 X1 X1 X2
(blue, green, pure white, X1
X1 X1
X1 X1 X1
X1 X1 X1
X1 yellow only)
(G)
Resistor
X1 X1 X1 X1 X1 X1
X1X2
X2X2
X1 X1X2
X2X2
X1 X1X2
X2X2
X1
X2 X2 X2 X2 X2 X1 X2
X2 X2
X2 X2 X2
X2 X2 X2
X2
X2 X2 X2 X2
•X2
SLDN-32M-∗
X2 (24V AC/DC) •X2SX2LDN-32-W
X2 SX2LDN-32MW-RG
(24V AC/DC) •X2 X2 • SLDN-32ST-∗ (24V AC/DC)
C
One-color full One-color full (white) (24V AC/DC) Spot illumination
(R)
(amber, blue, green, red, yellow) Two-color alternate
X1
X1X1 X1
X1X1 X2X2X2 X1
X1X1
X1 X1 X2
(G) X1
(G)(G)
X1 X1
X1 X1 X1
X1 (G)X2
X2 X2 X1 X1
X1
(G)(G)
(G)
X1 X1 X1 X1 X2 X2 X1 X1
X1X2 X1X2 X1
X2 X1X1 X1X2
X2X2
X1
X2X2
X1 X2X2
X1 (G) X2 (G) X2
X2 X2 (G)X1 (G)
X2 X2
X2 X2 X2
X2 X1 X1 X1 X2 X2
X2
X1 X1 X2 X1
X2 X2 X2 X2 X1 X1 X2 X2 (G)
X2 X2 X2 X2 X1 CC CX1 X2 X2
C
(R)
(R)(R)
(R) CC
C
X2 X2
(R) (R)
(R) X1 X2
C C
C
(R) C (R)
SLC40 Series (R) (R)
C
• SLDN-42M-∗ (24V AC/DC) • SLDN-42-W (24V AC/DC) • SLDN-42MW-RG • SLDN-42ST-∗
(R) (24V AC/DC)
One-color full (amber, blue, One-color full (white) (24V
X2
X2X2
AC/DC) Spot illumination
X1
X1X1 X1
X1X1 X1
X1X1
green,
X1 red, yellow) X1 Two-color
X2
(G)
(G)(G) alternate X1
X1 X1
X1 X1 X1
X1 (G)X2
X2 X2 X1 X1
X1
(G)(G)
(G)
X1 X1 X1 X1 X2 X2 X1 X1
X1X2
X2X2 X1X2
X2X2 X1
X2 X1X1
X2 X1X2
X2X2
X1 X1 (G)
X1 (G) X1
X2 X2 (G) (G) X2
X2 X2
X2 X2 X2
X2 X1 X1
X1 X2 X2
X2
X2 X2 X2 X2 X1 X1 X2 X2
X2 X2 X2 X2 X1 CC CX1 X2 X2
C
(R)
(R)(R)
(R) CC
C
(R) (R)
(R)
C C
C
(R) C (R)
(R) (R)

29
SLC30/40 Series Combination Display Lights Instructions

Operating Instructions
Type F, H, H2, L, V, G
Marking Plate/
Display Color
Light Source Color Screen Lens ON Color (Color Code) OFF Color
Type
(Note 1) (Note 2)
Matte Surface

Standard amber (A), blue (S), green (G), pure white (PW) (Type F only),
red (R), yellow (Y)
(using clear red/green (two-color alternate) (RG) (no spot illumination
White
lens) SLC30 SLC40 for red/green two-color alternate)
LED unit clear / white clear lens
Matte Surface

amber (TA), blue (TS), green (TG), red (TR), yellow (TY)
SLC30 SLC40
LED unit white / color clear lens Same as
Color Screen Matte Surface ON color

pure white (TPW, Type F only)


SLC30 SLC40
LED unit clear / white clear lens
Matte Surface

amber (SA), blue (SS), green (SG),


Gray Lens Legend pure white (SPW, Type F only), red (SR),
Gray
(Note 3) Color yellow (SY)
SLC30 SLC40
LED unit clear / black (Note 4) gray lens

Type C (split-window)
Marking Plate/
Display Color
Light Source Color Screen Lens ON Color (Color Code) OFF Color
Type
(Note 1) (Note 2)
Matte Surface

amber (A), blue (S), green (G), red (R), yellow (Y)
SLC30 SLC40
Standard LED lamp color / white clear lens
(using clear Matte Surface
White
lens)
pure white (PW)
SLC30 SLC40
LED lamp white / clear clear lens
Matte Surface

amber (SA), blue (SS), green (SG), red (SR),


yellow (SY)
SLC30 SLC40
Gray Lens LED lamp color / black (Note 4) gray lens Legend
Gray
(Note 3) Matte Surface Color

pure white (SPW)


SLC30 SLC40
LED lamp clear / black (Note 4) gray lens
Note 1: Place the marking plate and color screen with the matte surfaces facing each other. The insertion order can be interchanged if necessary.
Engrave on the flat surface of the screen/plate next to the lens.
Note 2: See page 24 for ordering the screen/plate as replacement parts.
Note 3: When ON: legends shown in the specified color on gray lens. When OFF: no legends shown on gray lens. Gray lens, black marking plate, and clear or color screen are used.
Note 4: Black marking plate has black coating. Engrave a reverse legend on the black-coated surface.

30
SLC30/40 Series Combination Display Lights Instructions

Type F Spot Illumination Color Screen/White Color Screen/Clear Screen


Spot illumination LED unit and spot illumination kit are used.
Dimensions
Type F Type F
LED bulb
Type F Spot F
Type Illumination
Spot Illumination
27
SLC30 27.0
27 5.3
SLC30 27.0
5.3

5.5 5.5
Spot illumination ø7
LED unit
ø7
Clear marking
plate White screen
25.4

1.0 1.0

0.8 0.8
1.0 1.0
Type F spot illumination kit 25.4
(Supplied with the supot illumination type SLC.
See page H-27 for details.)
For engraving area, see page 7.
Type F Type F
Marking on Films Type F Spot F
Type Illumination
In addition to white color screens or clear marking plates, legends Spot Illumination
35.8
SLC40 35.8 11
can be engraved on thin marking films on Type F windows. Two 35.8
sheets of 0.1-mm-thick films or one sheet of 0.2-mm-thick films is SLC40 35.8 11
applicable. Marking films are not supplied with the SLC units and
must be prepared by the user. ø7

8.4 8.4
ø7
Dimensions
SLC30N: 27 × 27 mm
SLC40N: 35.8 × 35.8 mm
34.1
Film Material

1.0 1.0
0.8 0.8
34.1

1.0 1.0
Polyester is recommended.

Placement of Marking Film


When using a marking film, place the matte surfaces of the For engraving area, see page 16.
marking plate and color screen in the same direction to make
a room of 0.2 mm for the marking film (matte surfaces are not All dimensions in mm.
facing each other). When not using a marking film, face the matte
surfaces of marking plate and color screen each other.

Using a marking film


Marking Film
0.2 mm
Lens
White Color Lens Frame
Screen
Color Screen
Matte Surfaces

Not using a marking film


Lens
White Color Lens Frame
Screen
Matte Surfaces
Color Screen

31
SLC30/40 Series Combination Display Lights Instructions

Operating Instructions
Removing the Windows
SLC30 Series
To remove the display window, insert the tip of a flat screwdriver SLC30 Series
into the slot on the bottom of the lens frame, and press down
lightly on the screwdriver as shown.
For types G and V, do not put excessive force to remove one
latch while pressing the other latch on the opposite side.
SLC40 Series (Extensible Windows)
The extensible window, featured on all SLC40 series units
except Types C, G, and L, can be removed simply by pulling the
upper portion out of the housing. For Types C, G, and L, insert
the tip of a flat screwdriver into the slot on the bottom of he lens
frame, and press up lightly.
When installing Type C windows, face the retaining latch with SLC40 Series
TOP marking upward.
All windows are shipped with the window retracted. After the
windows are installed in a panel, they can be extended as
required starting from the lowest row to the top row. Beware of
the orientation when installing the units. When transporting the
units, hold all windows in the retracted position.

Maximum Number of Windows


SLC30 Series SLC40 Series
LED Unit LED Unit
• Full Voltage 6, 12, 24V DC, w/Check Terminal, 2-color Alternate • Full Voltage 24V AC, w/Check Terminal, 2-color Alternate
Up to 10 rows/26 columns (windows must be 200 at maximum) Up to 7 rows/24 columns (windows must be 126 at maximum)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
1 1
2
2
3
4 3
5 4
6
5
7
8 6
9
10 200 windows maximum
7
126 windows maximum

LED Unit LED Unit


• Transformer 100/110V, 200/220V, 115/120, 230/240V AC • Transformer, 100/110, 200/220, 115, 120, 230, 240, 380, 400/440, 480V AC
Flasher, DC-DC Converter, Resistor Flasher, DC-DC Converter, Resistor
Up to 10 rows/26 columns (windows must be 75 at maximum) Up to 7 rows/24 columns (windows must be 60 at maximum)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
1 1
2
2
3
4 3
5 4
6
7 5
8 6
9
10 75 windows maximum 7
60 windows maximum

LED Lamp (Type C) LED Lamp (Type C)


• Full Voltage 6, 12, 24V DC • Full Voltage 6, 12, 24V DC
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
1 1
2 2
3
3
4
5 4
6 5
7
6
8
9 7 105 windows maximum
10 50 windows maximum

32
SLC30/40 Series Combination Display Lights Instructions

Replacing Lens, Marking Plate, and


Retaining Latch Retaining Latch
Color Screen (TOP side)
[Removal] Recess
The lens has retaining projections (one or two each on right
and left sides). To remove the lens, marking plate, and color
screen from the lens frame, push open the lens frame with
both hands as shown.
The lens can also be removed by inserting a screwdriver
into one of the sides with recesses. Sine the lens has SLC30 Series SLC40 Series
an orientation due to projections, be sure to insert the
screwdriver in the direction as shown.
Note: Take care not to damage or scratch the lens surface.

Retaining Projections Location


Series Type F, G Type C Type H Type L Type V
Latches Latch
Latch

Recesses
SLC30 Series Latches Latches
Recesses

(Not

Recesses
extensible)

Latches Latch
Latches
Latches
SLC40 Series Latch
(Extensible
Windows)
Not Extensible
Type G: Not extensible Not Extensible

[Installation] ➀ Lens Frame


Install the color screen and marking plate into the ➁ White Marking Plate
lens frame. ➂ Clear Screen/Color Screen
To install the lens, insert its retaining projections into 1 ➃ Lens
the recesses inside the lens frame, and press the
lens on the other side into the lens frame.

Retaining Lens 2
Replacing the LED Unit Projections 3
Ensure that power to the display lights has been turned off before removing the LED unit. 4

[Removal] [Installation]
Use the LED unit removal tool (MT-101) to TOP Side The LED unit has an orientation. To install TOP Side
pull out the LED unit. For SLC30 units, the LED unit, place the metal pins on the
pinch the top and bottom sides of the unit. LED unit to fit into the receptacles in the
For SLC40 units, pinch the right and left housing, and insert the LED unit.
sides of the unit.

Note: When removing the LED unit from the


housing, pull it out straight without pressing on
the LED unit terminals.

LED Unit Color Identification


Each LED unit has part no. and identification mark stamped.
Appearance Appearance
Color Code Mark Color Code Mark
SLC30 SLC40 SLC30 SLC40

Latches Red R
Red dot
Yellow Y P (Note)

Latches
Green G Latches
Green dot
Recesses


Amber A Amber dot Pure
PW P
 Latches
White
Blue S Blue dot
Latches

Red/
RG —
Green
Note: Yellow (Y) LED unit uses a pure white LED unit with a yellow
filter on the LED.

33
SLC30/40 Series Combination Display Lights Instructions

Replacing LED Lamps


SLC30, Type C
[Removal] [Installation]
Push lamp holder tool OR-44 into the LED lamp kit, and push and Insert the lamp into the lamp holder completely (lamps can be
turn clockwise to remove the lamp from the lamp holder. installed easily by using the handle part of lamp holder tool).

LED lamp Lamp holder

Insert completely.
Insert

Insert the lamp holder tool into the lamp holder.

Align the insertion guides of the lamp holder with the grooves in
the SLC unit. Push the lamp lightly and turn clockwise to install.
SLC40, Type C
Lamps can be replaced easily by using the lamp holder tool
OR-55. When removing the lamp, reflector does not have to be
removed.

Installation on Panel
Insert the units into a panel cut-out from the front, and install the mounting clips supplied with the units
from the back as shown below. Apply loctite on the screws to prevent loosening. The number of
mounting screws varies with the number of windows.
Tighten the screws to a torque of 0.39 N·m to 0.49 N·m.

Example of Mounting Clip Positions ( )


Columns
1 2 3 to 8 9 to 15 16 to 22 23 to 26
Rows Note: See below for Type V.

1 to 2
(Note)

4 to 6

7 to 10

No. of Mounting Clips


Columns
1 to 2 3 to 8 9 to 15 16 to 22 23 to 26
Rows

1 to 2 2 4 (6) 6 (8) 8 10
3 to 6 4 (6) 6 (8) 8 (10) 10 (12) 12 (14)
7 to 10 6 (8) 8 (10) 10 (12) 12 14
Note: Numbers in ( ) show the number of mounting clips required
for transformer, resistor, flicker, and DC-DC converter.

34
SLC30/40 Series Combination Display Lights Instructions

SLC30/40 Series Combination Display Lights Specification Sheet


Date of Order
Customer
Address
Phone No.
Contact

Part No. Color Code Designations


A ( ), G ( ), PW ( ), R ( ), S ( ), Y ( )
SLC 0 N- - B- TA ( ), TG ( ), TPW ( ), TR ( ), TS ( ), TY ( )
SA ( ), SG ( ), SPW ( ), SR ( ), SS ( ), SY ( )

Illumination Face Size & Color Screen Code Designations

This Side Up.


Columns 40 Series 30 Series

Rows 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26

4
40 Series

7
30 Series

10

Part No. Development


Color Designations
(Rows) (Columns)
A (0), G (5), PW( ), R (5), S (5), Y (5) • Color Code
SLC 30 N - 0 4 0 8 - DD 2 F B - TA ( ), TG ( ), TPW( ), TR ( ), TS ( ),TY ( ) When designating M, H2 for illumination face size code,
SA (5), SG (0), SPW( ), SR (0), SS (0), SY (5) or two or more LED colors, mark in the above table.

30: SLC30 Series


40: SLC40 Series Frame Color
B: Black (N1.5 Equivalent)
• Illumination Face Size
F, H, H2, L, V, G, M, C, FST
No. of Windows: A B Voltage LED Illumination
B (Columns) 6: 6V AC/DC ±5% (except for SLC40N) 1: 100/110V AC ±10% (transformer) 1: 110V DC (converter)
1: 12V AC/DC ±10% 2: 200/220V AC ±10% (transformer) 1: 100/110V AC/DC (resistor)
2: 24V AC/DC ±10%
A (Rows)

Type LED Illumination


(Type C) DD: SLC30/40 (Full Voltage) CD: SLC30/40 (DC-DC Converter)
DHM: SLC30/40 (Full Voltage w/Check Terminal) RN: SLC30/40 (Resistor)
R DW: SLC30/40 (2-color alternate) RNA: SLC30/40 (Blue/pure white Resistor)
G DF: SLC30/40 (Flasher Type) DDA: SLC30/40 (Blue/pure white Full Voltage)
DP: SLC30/40 (Split-window, Type C) TDA: SLC30/40 (Blue/pure white Transformer)
TD: SLC30/40 (Transformer)

35
SLC30 Series Combination Display with Control Units
Combination of display lights and control units reduce labor of switch installation and
minimizes installation space.
Switch for lamp test, external switch for system display can be integrated into the frame of
combination display lights.
• Various control units can be installed in the window
frame, with or without SLC units.
• Panel space can be reduced.
• Labor and time to install switches can be reduced.
• Flexibility of panel design is maximized.
• Up to 30 windows (3 rows × 10 columns) can be used.

Combination Display Lights Specifications


• One-color Full, Type F (30 × 30mm) SLC30: Solid wire ø1.6 × 2
• Operating voltage: 24V AC/DC Connection Wire Stranded wire 2 mm2 × 2
• Illumination color: SLC-LW: Stranded wire 1.25 mm2 maximum
Amber (A), Blue (S), Green (G), Pure White (PW), Red (R), SLC30: M3.5
Yellow (Y) Terminal Screw
SLC30-LW: M3.0
• Frame color: Black (B)
Insulation Resistance 100 MΩ minimum (500V DC megger)
Control Unit (SLC30-LW) SLC30: 2000V AC, 1 minute
Dielectric Strength SLC30-LW: 2500V AC, 1 minute
Pushbutton (Square, Round w/Square Bezel) (between terminals of the same pole:
• Contact: DPDT (gold or silver) 1000V AC, 1 minute)
• Operation: Momentary Operating Temperature –20 to 40°C (no freezing)
• Button color:
Black (B), Green (G), Red (R), Blue (S), Yellow (Y) Storage Temperature –25 to +60°C (no freezing)
Operating Humidity 45 to 85% RH (no condensation)
Illuminated Pushbutton
(Square, Round w/Square Bezel)
• Contact: DPDT (gold or silver)
Contact Ratings
• Operation: Momentary Rated Insulation
250V AC/DC
• Illumination color: Voltage
Amber (A), Green (G), Pure White (PW), Red (R), Blue (S), Gold contact: 3A
Yellow (Y) Rated Current
Silver contact: 5A

Selector Switch (Round w/Square Bezel) Gold contact: 125V AC/0.1A, 30V DC/0.1A
(resistive load)
Key Selector Switch (Round w/Square Bezel) Operating
Silver contact: 125V AC/3A, 250V AC/2A
• Contact: DPDT (gold or silver) Voltage/Current
30V DC/2A, 125V DC/0.4A
• Operation: 2 or 3-position, maintained (resistive load)

Operator Position and Contact Operation


Operation Angle
Combination Display Light Ratings
Left Center Right Operating Voltage 24V AC/DC
Amber, red: 12 mA
90° 2-position Left Contact Right Contact
NO NC NO NC
Left Contact Right Contact
NO NC NO NC
Rated Current
Blue, green, pure white, yellow: 11 mA
L R

C C C C

45° 3-position Left Contact Right Contact Left Contact Right Contact Left Contact Right Contact
NO NC NO NC NO NC NO NC NO NC NO NC
C
L R
C C C C C C

36
SLC30 Series Combination Display with Control Units

Dimensions All dimensions in mm.


(Front View) (Side View) (Rear View)

L 6 55.5 30

21 30 M3.5 Terminal Screw 9.2


1 row: 42, 2 rows: 72, 3 rows: 102

21

14

30
30

7.6
7.6
Panel thickness:
30 0.8 to 6 M3 Terminal Screw 8.2 8.2

6.3 30

A 66.7 Unit A
Illuminated Pushbutton 6.3
Pushbutton 6.3
No. of Columns 1 2 3 4 5 6 7 8 9 10 (With teminal cover: 68.1) Selector Switch 14.8
L 42 72 102 132 162 192 222 252 282 312 Key Selector Switch 34.3

Panel Cut-out Safety Precautions


M
See page 29.

Operating Instructions
1 row: 35 1. When using the insulation terminal cover (LW-VL2M) for the
2 rows: 65 control units
3 rows: 95
• Install the terminal cover on the SLC units before wiring. Ter-
minal covers cannot be installed after wiring.
• Ring crimping terminals cannot be installed when terminal
covers are used. Use spade terminals or wire directly.
2. Do not remove the operator part of control units from the
housing. Otherwise contacts may malfunction.
No. of
1 2 3 4 5 6 7 8 9 10 3. On key selector switches, do not attempt to remove the key
Columns
at any key retained position with excessive force (more than
M (mm) 35 65 95 125 155 185 215 245 275 305
approx. 70N). Otherwise the operator part detaches from the
housing, causing the contacts to malfunction.
4. Use a lamp holder tool (OR-55) when replacing lamps for
Panel Cut-out (Bottom View) control units.
Pushbutton 5. For wiring, use wires of a proper size to meet the voltage and
Selector Switch current requirements. Tighten the M3.5 terminal screws to a
SLC30 Illuminated Pushbutton
Key Selector Switch tightening torque shown below.

NC2 NC1 NC2 NC1


Terminal Screw Recommended Tightening Torque
X1
M3 0.6 to 1.0 N·m
X1 NO2 NO1 NO2 NO1
X2 M3.5 1.0 to 1.3 N·m
X2 C2 C1 C2 C1
6. Up to 10 SLC units (Type F equivalent) can be lit continuously.
When more units are mounted, consider the following
X1: Positive lamp terminal
X2: Negative lamp terminal
restrictions.
• Do not light more than 40% of the SLC units continuously, and
light the units in a checker pattern.
• When more than 40% of the units are lit continuously, limit the
Ordering Information lighting duration to 40 minutes. Before lighting the units again,
1. When ordering, complete the Specification Sheet on page 36. ensure that all units have cooled down.
2. Control units (SLC30-LW) can be mounted on the bottom row 7. For other operating instructions of display lights, see the
only. relevant pages of SLC30/40 catalog.
3. Jumpers (SLCN-JP34/-JP35) are used between combination 8. For other operating instructions of control units, see the relevant
display lights only. Jumpers can not be used between control pages of ø22 LW control unit catalog.
units, or between control units and combination display lights.
4. See page 24 to 26 for accessories.
5. Minimum unit size is 2 × 1 windows.

37
SLC30 Series Combination Display with Control Units

SLC30/40 Series Combination Display Lights with Control Units Specification Sheet

Date of Order
Customer
Address
Phone No.
Contact

Part No.

SLC30N- -DD2ML - For illumination color and control


unit, enter your requirements in the
diagram below.

Illumination Color & Control Unit Specification


TOP (up)
1 2 3 4 5 6 7 8 9 10
1
(TOP) 2 (TOP)

3
(Bottom Row)
Specification Notes
1. Use the specification diagram above for LED one-color Full (24V AC/DC) only. Upper
2. Control units can be mounted on the bottom row (the third row in the diagram above) only. Lower
Enter button or lens color code in the upper part and control unit code in the lower part
(see the table below for control unit code). Display lights can be specified on the bottom row.
3. Specify the TOP position (mounted onto the panel).

Control Unit Code


Code Style (gold contact) Code Style (silver contact)
1 Square Illuminated Pushbutton (DPDT) 2 Square Illuminated Pushbutton (DPDT)
Round w/Square Bezel Illuminated Pushbutton Round w/Square Bezel Illuminated Pushbutton
3 4
(DPDT) (DPDT)
5 Square Pushbutton (DPDT) 6 Square Pushbutton (DPDT)
7 Round w/Square Bezel Pushbutton (DPDT) 8 Round w/Square Bezel Pushbutton (DPDT)
9 Selector Switch (2-position) 10 Selector Switch (2-position)
11 Selector Switch (3-position) 12 Selector Switch (3-position)
13∗ Key Selector Switch (2-position) 14* Key Selector Switch (2-position)
15* Key Selector Switch (3-position) 16* Key Selector Switch (3-position)
∗ Refer to the below table for key retaining positions.

Rows Columns
Key Code A B C
SLC30N - 0 2 0 3 - DD 2 ML B 2-position L R L R L R L C R:
Maintained Key can be released from these positions.
SLC30 Series
No. of Windows
Key Code A B C D E G H
3-position L C R C C C
L C R L
C
R L
C
R L R L R L R
Maintained
Columns: 01 to 10
Rows: 01 to 03

Frame Color: Black TOP (up)


1 2 3 4 5
Part No. with Control Unit
1

LED One-color Full LED Illumination Voltage Code: 2


(Full Voltage 24V AC/DC)
TOP 2 R Y G
3 A R
13B 3 5

EP5161A SLC March 2023

38
Ordering Terms and Conditions
Thank you for using IDEC Products.
By purchasing products listed in our catalogs, datasheets, and the like (hereinafter referred to as “Catalogs”) you agree to be bound by these terms and conditions. Please read
and agree to the terms and conditions before placing your order.

1. Notes on contents of Catalogs 3. Inspections


(1) Rated values, performance values, and specification values of IDEC products We ask that you implement inspections for IDEC products you purchase without
listed in this Catalog are values acquired under respective conditions in delay, as well as thoroughly keep in mind management/maintenance regarding
independent testing, and do not guarantee values gained in combined handling of the product before and during the inspection.
conditions.
Also, durability varies depending on the usage environment and usage
4. Warranty
conditions. (1) Warranty period
(2) Reference data and reference values listed in Catalogs are for reference The warranty period for IDEC products shall be one (1) year after purchase or
purposes only, and do not guarantee that the product will always operate delivery to the specified location. However, this shall not apply in cases where
appropriately in that range. there is a different specification in the Catalogs or there is another agreement
(3) The specifications / appearance and accessories of IDEC products listed in in place between you and IDEC.
Catalogs are subject to change or termination of sales without notice, for (2) Warranty scope
improvement or other reasons. Should a failure occur in an IDEC product during the above warranty period
(4) The content of Catalogs is subject to change without notice. for reasons attributable to IDEC, then IDEC shall replace or repair that
product, free of charge, at the purchase location / delivery location of the
2. Note on applications product, or an IDEC service base. However, failures caused by the following
(1) If using IDEC products in combination with other products, confirm the reasons shall be deemed outside the scope of this warranty.
applicable laws / regulations and standards. i. The product was handled or used deviating from the conditions /
Also, confirm that IDEC products are compatible with your systems, machines, environment listed in the Catalogs
devices, and the like by using under the actual conditions. IDEC shall bear no
ii. The failure was caused by reasons other than an IDEC product
liability whatsoever regarding the compatibility with IDEC products.
iii. Modification or repair was performed by a party other than IDEC
(2) The usage examples and application examples listed in Catalogs are for
reference purposes only. Therefore, when introducing a product, confirm the iv. The failure was caused by a software program of a party other than
performance and safety of the instruments, devices, and the like before use. IDEC
Furthermore, regarding these examples, IDEC does not grant license to use v. The product was used outside of its original purpose
IDEC products to you, and IDEC offers no warranties regarding the ownership vi. Replacement of maintenance parts, installation of accessories, or the like
of intellectual property rights or non-infringement upon the intellectual was not performed properly in accordance with the user’s manual and
property rights of third parties. Catalogs
(3) When using IDEC products, be cautious when implementing the following. vii. The failure could not have been predicted with the scientific and
i. Use of IDEC products with sufficient allowance for rating and technical standards at the time when the product was shipped from
performance IDEC
ii. Safety design, including redundant design and malfunction prevention viii. The failure was due to other causes not attributable to IDEC (including
design that prevents other danger and damage even in the event that an cases of force majeure such as natural disasters and other disasters)
IDEC product fails Furthermore, the warranty described here refers to a warranty on the IDEC
iii. Wiring and installation that ensures the IDEC product used in your product as a unit, and damages induced by the failure of an IDEC product are
system, machine, device, or the like can perform and function according excluded from this warranty.
to its specifications 5. Limitation of liability
(4) Continuing to use an IDEC product even after the performance has The warranty listed in this Agreement is the full and complete warranty for IDEC
deteriorated can result in abnormal heat, smoke, fires, and the like due to products, and IDEC shall bear no liability whatsoever regarding special damages,
insulation deterioration or the like. Perform periodic maintenance for IDEC indirect damages, incidental damages, or passive damages that occurred due to an
products and the systems, machines, devices, and the like in which they are IDEC product.
used.
(5) IDEC products are developed and manufactured as general-purpose products 6. Service scope
for general industrial products. They are not intended for use in the following The prices of IDEC products do not include the cost of services, such as dispatching
applications, and in the event that you use an IDEC product for these technicians. Therefore, separate fees are required in the following cases.
applications, unless otherwise agreed upon between you and IDEC, IDEC shall (1) Instructions for installation / adjustment and accompaniment at test operation
provide no guarantees whatsoever regarding IDEC products. (including creating application software and testing operation, etc.)
i. Use in applications that require a high degree of safety, including nuclear (2) Maintenance inspections, adjustments, and repairs
power control equipment, transportation equipment (railroads / airplanes (3) Technical instructions and technical training
/ ships / vehicles / vehicle instruments, etc.), equipment for use in outer (4) Product tests or inspections specified by you
space, elevating equipment, medical instruments, safety devices, or
any other equipment, instruments, or the like that could endanger life or The above content assumes transactions and usage within your region. Please
human health consult with an IDEC sales representative regarding transactions and usage outside
ii. Use in applications that require a high degree of reliability, such as of your region. Also, IDEC provides no guarantees whatsoever regarding IDEC
provision systems for gas / waterworks / electricity, etc., systems that products sold outside your region.
operate continuously for 24 hours, and settlement systems
iii. Use in applications where the product may be handled or used deviating
from the specifications or conditions / environment listed in the Catalogs,
such as equipment used outdoors or applications in environments
subject to chemical pollution or electromagnetic interference
If you would like to use IDEC products in the above applications, be sure
to consult with an IDEC sales representative.

Head Office 6-64, Nishi-Miyahara-2-Chome, Yodogawa-ku, Osaka 532-0004, Japan


www.idec.com
USA IDEC Corporation Singapore IDEC Izumi Asia Pte. Ltd. China IDEC (Shanghai) Corporation Japan IDEC Corporation
EMEA APEM SAS Thailand IDEC Asia (Thailand) Co., Ltd. IDEC Izumi (H.K.) Co., Ltd.
India IDEC Controls India Private Ltd. Taiwan IDEC Taiwan Corporation

Specifications and other descriptions in this brochure are subject to change without notice.

2023 IDEC Corporation, All Rights Reserved.