Ep5161a SLC
Ep5161a SLC
Shape
Type F Type F
(spot illumination) Type C Type H (full) Type L Type V Type G
(Basic Size) Type H2 (2-way split)
F, H, L, V, G C only
30mm
A (amber), G (green),
A (amber), G (green),
PW (pure white) *, R (red),
Illumination Color PW (pure white), R (red),
S (blue), Y (yellow), Red (R)/G (green)
S (blue), Y (yellow)
* PW is available with Type F only
No. of Transformer/Resistor
Windows 1 to 75 (Type F equivalent) —
Flasher/DC-DC
Converter
• Jumper available
Remarks
• 2-color alternate, check terminal, flasher
Page 5
1
SLC30/40 Series Combination Display Lights Selection Guide
Type F Type F
Type C Type H Type L Type V Type G
(Basic Size) (spot illumination)
F, H, L, V, G C only
40mm
A (amber), G (green),
A (amber), G (green),
PW (pure white) *, R (red),
PW (pure white), R (red),
S (blue), Y (yellow), Red (R)/G (green)
S (blue), Y (yellow)
* PW is available with Type F only
M3.5
2-color illumination, Type C, Check terminal: M3
1 to 60 (Type F equivalent) —
14
2
SLC30/40 Series Combination Display Lights Selection Guide
Shape
Front Back
Flange size 30
Mounting hole ø22
Degree of protection IP65 (IEC 60529)
3
SLC30 Series Combination Display Lights
Highly bright “Super LED” unit improves visibility and safety.
• Eight types of illumination faces to choose
from. Compact combination display lights. An Example of 15-window size
• Super bright Super LED.
• The fingersafe spring-up terminals reduce Spot illumination is
available with type F only.
wiring time and prevent electrical shocks.
• The insulated jumper, when used on
fingersafe spring-up terminals, eliminates
the need of terminal cover.
• Legends can be engraved on the attached
marking plate. One or two thin marking
sheets (not attached) can also be installed
(Type F only).
• Spot illumination available for easy recognition
in bright environment (Type F only)
• UL and c-UL recognized, EN compliant.
(*1)
Columns
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
1
Rows 2
3
4
LED 5
6
7
8
9
10 Maximum Number
of Windows
4
SLC30 Series Combination Display Lights
Configuration
Illumination Face
• See page 31 for the
combination of illumination Type H
windows. Type F Type C Type L Type V Type G
Type H2
• Lens (acrylic) • Lens (acrylic)
Type F, H, H2, L, V, G
Marking Plate/Color Screen
Display Color Type Light Source Lens ON Color (Color Code) OFF Color
(one each) (Note 2)
Standard amber (A), blue (S), green (G), pure white (PW), red (R), yellow (Y),
clear / white White
(using clear lens) Clear red/green 2-color alternate (RG) (Note 1)
Lens Same as
Color Screen LED Unit color / white amber (TA), blue (TS), green (TG), red (TR), yellow (TY)
ON color
Gray amber (SA), blue (SS), green (SG), pure white (SPW),
Gray Lens black (Note 3) / clear Lens: gray Legend Color Gray
Lens red (SR), yellow (SY)
Note 1: Spot illumination is not available with red/green 2-color alternate (RG).
Note 2: The order to insert clear marking plate, color screen, and white screen can be interchanged if necessary.
Marking plate/color screen are interchangeable. Engrave markings on the flat surface of the plate or screen next to the lens.
Note 3: Black marking plate has black coating. Engrave a reverse legend on the black-coated surface.
Type C (split-window)
Marking Plate/Color Screens
Display Color Type Light Source Lens ON Color (Color Code) OFF Color
(one each)(Note 4)
Standard color / white Clear amber (A), blue (S), green (G), red (R), yellow (Y),
White
(using clear lens) clear / white Lens pure white (PW)
LED Lamp
black (Note 5) / color Gray amber (SA), blue (SS), green (SG), red (SR), yellow (SY)
Gray Lens Lens: gray Legend Color Gray
Lens
black (Note 5) / clear pure white (SPW)
Note 4: The order to insert clear marking plate, color screen, and white screen can be interchanged if necessary.
Marking plate/color screen are interchangeable. Engrave markings on the flat surface of the plate or screen next to the lens.
Note 5: Black marking plate has black coating. Engrave a reverse legend on the black-coated surface.
(V)
Combination Example of 15 Windows
Mounting Clip
• LED Lamp (for Type C only, SLC-3K1
SX6S/8 base) (2 lamps for 1 (supplied)
window equivalent to Type F)
6, 12, 24V AC/DC 24V DC (Except Type C) 24V DC (Type F only) 24V AC/DC (Except Type C)
One-color full One-color full One-color full
5
SLC30 Series Combination Display Lights
Specifications
Light Source LED Unit LED Lamp
DC-DC
Input Full Voltage Transformer Resistor Full Voltage
Converter
One-color
Two-color One-color × 2
Illumination One-color w/check terminal Flasher One-color
Alternate Split-window (Type C)
(Note 1)
Fingersafe Spring-up Provided —
(Note 2) Provided Provided
Terminal (except for check terminal) (Note 2)
Rated Voltage 12V AC/DC 24V AC/DC 24V AC/DC 24V DC 100/110V AC ±10% 110V DC 100/110V 6V AC/DC 12V AC/DC 24V AC/DC
(AC: 50/60Hz) ±10% ±10% ±10% ±10% 200/220V AC ±10% (90 to 140V DC) AC/DC ±10% ±10% ±10% ±10%
Maximum Current 0.5W +
Same as internal LED Unit 1.7 1.4 1.5 Same as internal LED
Draw (VA) internal LED
Rated Voltage 12V AC/DC 24V AC/DC 24V DC 24V AC/DC 6V AC/DC 12V AC/DC 24V AC/DC
7 mA 8 mA 8 mA
Green,
Red: 12 mA (Note 7) (Note 7) (Note 7)
pure white, 12 mA 11 mA (Note 6) 11 mA (Note 6)
Built-in LED Unit/Lamp
Green: 11 mA
yellow
Blue 12 mA 11 mA (Note 6) 11 mA (Note 6) 7 mA (Note 7) 8 mA (Note 7) 8 mA (Note 7)
Amber (A), blue (S), green (G),
Illumination Color Red (R)/ Amber (A), blue (S), green (G), Amber (A), blue (S), green (G),
red (R), pure white (PW),
(code) green (G) pure white (PW), red (R), yellow (Y) pure white (PW), red (R)
yellow (Y) (Note 5)
Base Plug-in unit type SX6S/8
LED Life (reference) Approx. 50,000 hours (when used on complete DC, luminance reduces to 50% of the initial intensity)
No. of Units 1 LED unit per window of basic Type F 1 LED lamp per split-window type
Flashing Period
— 0.5 ±0.2 sec — —
(Note 3)
Insulation Resistance 100 MΩ between live and dead parts (500V DC megger)
2500V AC (1 minute) 2000V AC 2000V AC (1 minute)
Dielectric Strength 2000V AC (1 minute) between live and dead parts
between live and dead parts (1 minute) between live and dead parts
Operating
–20 to +40°C –10 to +40°C –20 to +40°C –10 to +40°C –20 to +40°C –20 to +40°C
Temperature (Note 4)
Storage Temperature –25 to +60°C (no freezing)
Illumination Face (H × W) 28 × 28 13 × 28 28 × 58 28 × 88 58 × 28 58 × 58
Illumination Unit
Size (mm)
Pollution Degree 3
6
SLC30 Series Combination Display Lights
Dimensions
[Front View] a: No. of Rows b: No. of Columns
Type F Type F Type H Type H2 (2-way split)
B = (30b + 12) B = (60b + 12)
(Spot Illumination) B=(60b+12)
21 30 30 36 60
Spot Illumination 36 60
5.3
5.5
21
21
21
A = (30a + 12)
30
30
30
A=(30a+12)
A = (30a + 12)
30
30
30
30
30
30
60
30 60
13.5
51 90 36 60 21 30 30
21 30 30
30
21
A = (30a + 12)
36
15 15
30
A = (60a + 12)
A = (30a + 12)
30
36
A = (60a + 12)
60
30
60
15 15
60
90 60 30
Type F Dimensions & No. of Windows (Type C, H, L, V, and G can be converted into Type F.)
Columns b 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
Dimensions B 42 72 102 132 162 192 222 252 282 312 342 372 402 432 462 492 522 552 582 612 642 672 702 732 762 792
Rows Panel
Cut-out (D)
(35) (65) (95) (125) (155) (185) (215) (245) (275) (305) (335) (365) (395) (425) (455) (485) (515) (545) (575) (605) (635) (665) (695) (725) (755) (785)
a A (C)
01 42 (35) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
02 72 (65) 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52
03 102 (95) 3 6 9 12 15 18 21 24 27 30 33 36 39 42 45 48 51 54 57 60 63 66 69 72 75 78
04 132 (125) 4 8 12 16 20 24 28 32 36 40 44 48 52 56 60 64 68 72 76 80 84 88 92 96 100 104
05 162 (155) 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130
06 192 (185) 6 12 18 24 30 36 42 48 54 60 66 72 78 84 90 96 102 108 114 120 126 132 138 144 150 156
07 222 (215) 7 14 21 28 35 42 49 56 63 70 77 84 91 98 105 112 119 126 133 140 147 154 161 168 175 182
08 252 (245) 8 16 24 32 40 48 56 64 72 80 88 96 104 112 120 128 136 144 152 160 168 176 184 192 200 —
09 282 (275) 9 18 27 36 45 54 63 72 81 90 99 108 117 126 135 144 153 162 171 180 189 198 — — — —
10 312 (305) 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 — — — — — —
2. External dimensions are represented by A for rows and B for columns in boldface.
3. Panel cut-out dimensions are shown in ( ), for height (C) and width (D). Panel cut-out
tolerance is +1.0 to –0 mm (for one window: +0.6 to –0.4mm).
4. Total number of windows, dimensions, panel cut-out • Type L — Type F equivalent: 3 windows
➀ For Type C, H, L, V, and G, convert the numbers of rows Height: 1 row
[Example] and columns into Type F (basic size) equivalents. Width: 3 columns
• Type C — Type F equivalent: 2 split-windows consist • Type G — Type F equivalent: 4 windows
of one window.
Height: 2 rows
H Width: 2 columns
H 1 • Type H — Type F equivalent: 2 windows
C F Height: 1 row
C 2 Width: 2 columns
F G
C F V
C 3 • Type V — Type F equivalent: 2 windows.
L Height: 2 rows
6 Width: 1 column
4 5
2 3 ➁ The combination example at left consists of 3 rows by 6 columns.
1 ➂ The above table shows: No. of windows: 18
Dimensions: 102H × 192W mm
Panel cut-out: 95H × 185W mm
7
SLC30 Series Combination Display Lights
Dimensions
[Side & Rear Views]
Type F (Type H, L, V, and G are the same in side and rear views as Type F.)
30 30
3030
6
6
6
Panel Thickness 0.8 to 6
0.8 to 6
Panel Thickness
55.5
59.5
83.5
Thickness
82
0.8
Panel to 6
30 M3.5 Terminal Screws
30 M3.5 Terminal Screws 6.2 4 30 M3 Check Terminal 30
9.2
9.2 M3.5 Terminal Screws 8 M3.5 Terminal Screws
14
14
14
14
30
30
30
30
• w/Check Terminal
Terminal X1 is a positive pole; Terminal X2 and • Terminals X1 and X2 are positive and
C (check terminal) are negative poles. negative poles, respectively.
• Two-color Alternate
Red (R) illumination: X1 positive, C negative
Green (G) illumination: X1 positive, X2 negative
Type C (split-window)
• Transformer • Resistor
• One-color full • One-color full • Full Voltage
• 100/110, 200/220V AC/DC • 100/110V AC/DC • 6, 12, 24V AC/DC
• 110VDC (DC-DC Converter) • One-color full, 2 × LED lamps,
Split-window type
SLC-3KL 30
30
6
6
6
57.5
83.5
100/110V,
X2
4
30
30
30
8
SLC30 Series Combination Display Lights
Dimensions
All dimensions in mm.
[One-window, Type F only]
Full Voltage 12, 24V AC/DC, One-color Full Spot Illumination
Panel Thickness 0.8 to 6 Mounting Clip SLC-3K1
5.3 Panel Cut-out
M3.5
Terminal Screws +0.6
35 –0.4
5.5
30
30
14
+0.6
–0.4
35
42 6 55.5 9.2 42
14
42 6 59.5 6.2 4
Flasher 24V DC
Panel Thickness 0.8 to 6 Mounting Clip SLC-3K1 • On flasher type, Terminals X1 and X2 are positive
M3.5 and negative poles, respectively.
Terminal Screws • See page 23 for terminal covers.
30
14
42 6 83.5 9.2
14
42 6 72.3 9.2
14
42 6 83.5 9.2
14
42 6 83.5 9.2
9
SLC30 Series Combination Display Lights
Flasher Note: Jumpers cannot be used when using both Type C and fingersafe
Circuit spring-up terminals.
Negative
X2 [Examples of Using Jumpers]
Fingersafe Spring-up Terminal)
• For w/check terminal and two-color alternate units, terminal X1 is
a positive pole; Terminals X2 and C (check terminal) are negative When connecting two windows
Using one SLCN-JP35 jumper
poles.
Arrows indicate access directions for
wiring terminals.
X1 (w/Check Terminal Type Connection Diagram)
C X1
Positive
When connecting three windows
C Using two SLCN-JP35 jumpers
X2 Negative LED
Module
X2
Negative
X1
Common
Positive
C
Red (R)
Negative LED Module
Jumpers (SLCN-JP34/35) have an orientation.
Ensure that jumpers are installed correctly.
X2
Negative
Green (G)
Correct Incorrect
X2
X3
Lower
10
SLC30 Series Combination Display Lights
07 07 DF 24V DC ±10% 2
(Type F only) • Type H2 (Note 1) Red / Green RG
08 08 100/110V AC ±10% 1 (2-way split)
Transformer (A, G, R, Y) TD
09 09 200/220V AC ±10% 2 30 × 60 mm
• Color Screen
10 10 100/110V AC ±10% 1 Combination (Code)
Transformer (PW, S) TDA H2
11 200/220V AC ±10% 2 When color display is
A light barrier, clear required at power off,
12 Transformer / Type H2 only 100/110V AC ±10% 1 marking plate, and order color screens. For
TDC color screen for 2-way
details, see page 31.
13 (Combination of S and A, G, R, Y) 200/220V AC ±10% 2 split illumination are
supplied.
DC-DC Converter (A, G, R, Y) CD 110V DC (90 to 140V DC) 1
Amber TA
14
• Type L Green TG
15 Resistor (A, G, R, Y) RN 100/110V AC/DC ±10% 1
30 × 90 mm
6
Red TR
16 6V AC/DC ±10% (LFTD-6∗)
LED Lamp
26 Yellow SY
115/120V AC ±10% 12
Transformer (PW, S) TDA • Type L, V, and G
230/240V AC ±10% 24
cannot be split-
Transformer / Type H2 only 115/120V AC ±10% 12 illuminated.
TDC • Type C
(Combination of S and A, G, R, Y) 230/240V AC ±10% 24 • Enter the required
(15 × 30 mm) × 2 number of color
DC-DC Converter (PW, S) CDA 110V DC (90 txo 140V DC) 1 C screens in ( ).
Resistor (PW, S) RNA 100/110V AC/DC ±10% 1
One-color Full × 2 split 6V AC/DC ±10% (LFTD-6S) × 2 6
• Type F Spot
window (Type C)
(combination of PW, DPA 12V AC/DC ±10% (LFTD-1S) × 2 1 Illumination
LED Lamp
11
SLC30 Series Combination Display Lights
• Type C (split-window)
Type F equivalent: 1 window
Row (1), Column (1)
[Designation Examples]
Ex. 1 SLC30 Series • When more than one color is
Units in one color required for LED.
Type F, 20 windows • When a particular arrangement of
color screen is required.
Columns Color screen: Type F, 20 windows Specify each color code on the
4 5 R (20) = 20 specification sheet.
2 3
1 Columns
Color Code
• When color screen is
1 Rows 1 2 3 4 5 6
Rows required, specify the color
2 screen code. R R R R R
1 +
3 Ex.
Color Code G G G G G +
4 2
Color Screen Code Y Y Y Y Y
3 +
Ex. 2 SLC30 Series 4
A A A A A +
Type H, 9 windows (Type F equivalent: 3 rows by 6 columns) 5 + + + + + +
Columns Color screen: Type H, 9 windows Specify each color code on the
R (9) = 9 specification sheet.
4 5 6
2 3 Columns
1 Color Code
• When color screen is
Rows 1 required, specify the color
Rows 1 2 3 4 5 6 7
2 screen code. PW R R +
1
3 Ex. PW R R
Color Code 2 +
Color Screen Code PW G G +
3
4 + + + + + + +
1 + DD2
2 +
SLC30N-0304- DD 2 FB(8) + TD 1 FB(4) - R (12) 3 +
TD1
Specify the position of the units and each voltage on the specification sheet.
Columns
Ex. 4 When ordering a combination of units with different illumination colors, specify Part No. as follows. Color Code
Rows 1 2 3 4 5
PW R R R
Example: Full voltage 24V AC/DC, Red (6), Pure White (2) Specify the position of the units 1 +
and each color code on the PW R R R
2 +
SLC30N-0204-DD2FB(6) + DDA2FB(2) - R(6)PW(2) specification sheet.
+ + + + +
Red Pure White Designation
Red: 6, Pure White: 2
Columns
Ex. 5 When ordering a combination of units with different illumination colors for four windows of type C, Color Code
12
SLC40 Series Combination Display Lights
Highly bright “Super LED” unit improves visibility and safety.
• Eight types of illumination faces in 40mm size.
• Extensible window ensures high visibility An Example of 12-window size
when installed at high places (except C, L, G).
• Super bright Super LED. Spot illumination is
• The fingersafe spring-up terminals save available with type F only.
wiring time and prevent electrical shocks.
• The insulated jumper, when used on
fingersafe spring-up terminals, eliminates
the need of terminal cover.
• Legends can be engraved on the attached
marking plate. One or two thin marking
sheets (not attached) can also be installed
(Type F only).
• Spot illumination available for easy
recognition in bright environment (Type F only).
• UL and c-UL recognized, EN compliant
(*1)
A wide variety of illumination face sizes Extensible windows The Fingersafe Spring-up terminals
Type F: 40H × 40W mm (Basic size) Easy to recognize at high reduce wiring time.
Type F spot illumination: 40H × 40W mm places (except Type C, L, The integrated terminal cover and
Type C: 20H × 40W mm × 2 (Split-window type) and G) insulated jumpers prevent electic
shocks.
Type H: 40H × 80W mm
Type L: 40H × 120W mm Application Example of Jumpers
Type V: 80H × 40W mm
Type G: 80H × 80W mm
Combined construction is availble.
1
2
3
Rows
4
LED illumination 5
6
Maximum Number of
7
Windows for LED
13
SLC40 Series Combination Display Lights
Configuration
Illumination Face
• See page 31 for the
combination of illumination
windows. Type F Type C Type H Type L Type V Type G
Type F, H, L, V, G
Marking Plate/Color Screen
Display Color Type Light Source Lens ON Color (Color Code) OFF Color
(one each) (Note 1) (Note 2)
Standard amber (A), blue (S), green (G), pure white (PW), red (R), yellow (Y),
clear / white White
(using clear lens) Clear red/green 2-color alternate (RG) (Note 1)
Lens Same as
Color Screen LED Unit color / white amber (TA), blue (TS), green (TG), red (TR), yellow (TY)
ON color
Gray amber (SA), blue (SS), green (SG), pure white (SPW),
Gray Lens black (Note 3) /clear Lens: gray Legend Color Gray
Lens red (SR), yellow (SY)
Note 1: Spot illumination is not available with red/green 2-color alternate (RG).
Note 2: The order to insert clear marking plate, color screen, and white screen can be interchanged if necessary.
Marking plate/color screen are interchangeable. Engrave markings on the flat surface of the plate or screen next to the lens.
Note 3: Black marking plate has black coating. Engrave a reverse legend on the black-coated surface.
Type C (split-window)
Marking Plate/Color Screen
Display Color Type Light Source Lens ON Color (Color Code) OFF Color
(one each) (Note 4)
Standard color / white Clear amber (A), blue (S), green (G), red (R), yellow (Y)
White
(using clear lens) clear / white Lens pure white (PW)
LED Lamp
black (Note 5) / color Gray amber (SA), blue (SS), green (SG), red (SR), yellow (SY)
Gray Lens Lens: gray Legend Color Gray
black (Note 5) / clear Lens pure white (SPW)
Note 4: The order to insert clear marking plate, color screen, and white screen can be interchanged if necessary.
Marking plate/color screen are interchangeable. Engrave markings on the flat surface of the plate or screen next to the lens.
Note 5: Black marking plate has black coating. Engrave a reverse legend on the black-coated surface.
(H • Frame Cover
(H )
) Black (B)
(L )
• LED Unit for (F )
• LED Unit
Spot Illumination
(C
)
(C
)
• Mounting Clip
SLC-3K1
• LED Lamp (for Type C
(supplied)
only, BA9S/13 base)
(2 lamps for 1 window
equivalent to Type F)
24V AC/DC 24V DC (Except Type C) 24V DC (Type F only) 24V AC/DC (Except Type C)
One-color full One-color full One-color full
• The illustration above shows combination examples of windows. One-window is available in Type F.
14
SLC40 Series Combination Display Lights
Specifications
Light Source LED Unit LED Lamp
Rated Voltage 24V AC/DC 24V AC/DC 24V AC/DC 24V AC/DC
Amber
Blue
Rated Current
(Note 6)
Pure White
Red: 15 mA
15 mA (Note 5) 15 mA 7 mA
Green: 15 mA
Built-in LED Unit/Lamp
Green
Red
Yellow
Amber (A), blue (S),
Illumination Amber (A), blue (S), green (G), Red (R)/ Amber (A), blue (S), green (G), pure white (PW),
green (G), pure white (PW),
Color (code) pure white (PW), red (R), yellow (Y) green (G) red (R), yellow (Y)
red (R), Y (yellow)
LED Life (reference) Approx. 50,000 hours (when used on complete DC, luminance reduces to 50% of the initial intensity)
Lens Frame Color & Frame Cover Color Black (Munsell N1.5 equivalent)
Pollution Degree 3
Note 7: Flasher, one-window, pure white illumination, and spot illumination are available in Type F only.
15
SLC40 Series Combination Display Lights
Dimensions
[Front View] a: No. of Rows b: No. of Columns
Type F Type F Type H Type V
(Spot Illumination)
B = (40b + 16) B = (80b + 16) B = (40b + 16)
136
28 40 40 28 40 40 48 80 28 40 40
11 40
8.4
28
28
28
A = (40a + 16)
A = (40a + 16)
ø7
40
48
A = (80a + 16)
8.4
40
40
40
80
40
40
40
80
40 (SLC40N-0203-TDFSTB) 80
20 20 18
A = (40a + 16)
28
A = (40a + 16)
48
A = (80 + 16)
80
40
40
80
20 20
40
120 40
80
Type F Dimensions & No. of Windows (Type C, H, L, V, and G can be converted into Type F.)
Columns b 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Rows Dimensions B 56 96 136 176 216 256 296 336 376 416 456 496 536 576 616 656 696 736 776 816 856 896 936 976
Panel
Cut-out (D)
a A (45) (85) (125) (165) (205) (245) (285) (325) (365) (405) (445) (485) (525) (565) (605) (645) (685) (725) (765) (805) (845) (885) (925) (965)
(C)
01 56 (45) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
02 96 (85) 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48
03 136 (125) 3 6 9 12 15 18 21 24 27 30 33 36 39 42 45 48 51 54 57 60 63 66 69 72
04 176 (165) 4 8 12 16 20 24 28 32 36 40 44 48 52 56 60 64 68 72 76 80 84 88 92 96
05 216 (205) 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120
06 256 (245) 6 12 18 24 30 36 42 48 54 60 66 72 78 84 90 96 102 108 114 120 — — — —
07 296 (285) 7 14 21 28 35 42 49 56 63 70 77 84 91 98 105 112 119 126 — — — — — —
4. Total number of windows, dimensions, panel cut-out • Type L — Type F equivalent: 3 windows
➀ For Type C, H, L, V, and G, convert the numbers of rows Height: 1 row
and columns into Type F (basic size) equivalents. Width: 3 columns
L V 1
V • Type C — Type F equivalent: 2 split-windows consist
F • Type G — Type F equivalent: 4 windows
F 2 of one window.
F
F Height: 2 rows
F H 3 Width: 2 columns
H
H
5
6 • Type H — Type F equivalent: 2 windows
4 Height: 1 row
3
2 Width: 2 columns
1
16
SLC40 Series Combination Display Lights
Dimensions
[Side & Rear Views]
• Full Voltage • Full Voltage • Full Voltage
• 24V AC/DC • One-color full • One-color full
• One-color full • w/Check Terminal 24V DC • Flasher 24V DC (Type F only)
• For applicable terminal cover, see page 23. • Two-color alternate 24V AC/DC • For applicable terminal cover, see page
• Spot illumination 24V AC/DC • For applicable terminal cover, see page 23. 23.
40 40 40
6
Panel Thickenss
Panel Thickness
Panel Thickness
87.5
69.9
73
0.8 to 6
0.8 to 6
0.8 to 6
40
M3 Check Terminal 11 M3.5 Terminal Screws
40 M3.5
Terminal Screws 8.3 5.5 40 M3.5 Terminal Screws
11
X1 X1
19
40
X1 X1 X2 X2
C C
X1 X1
19
19
X1 X1
40
X2 X2
X2 X2
X2 X2
40
X1 X1
C C
X1 X1
X2 X2
X2 X2
6
6
Panel Thickness
Panel Thickness
Panel Thickness
87.5
66.5
0.8 to 6
87.5
SLC-3K1
0.8 to 6
0.8 to 6
40 M3.5
9.2
40
M3.5 11 Terminal Screws
11 Terminal Screws
20
X1 X1 X1
19
X1 X1 X2 X2 X2
40
19
X2 X2
40
X1 X1 X1
40
X1 X1 X2 X2 X2
X2 X2
40 11
M3.5 Terminal Screws
• On DC-DC Converter type units, • Terminal X1 is COM terminal.
Terminals X1 and X2 are positive and • For applicable terminal cover, see page 23.
negative poles, respectively.
17
SLC40 Series Combination Display Lights
Dimensions
All dimensions in mm.
[One-window, Type F only]
Full Voltage 24V AC/DC, One-color Full Spot Illumination
Panel Thickness 0.8 to 6 Mounting Clip SLC-3K1
Panel Cut-out
M3.5 Terminal Screws 11 +0.6
45 –0.4
8.4
40
40
+0.6
11
–0.4
45
56 6 69.9 19 56
13.8
56 6 73 19
Flasher 24V DC
Transformer 100/110, 200/220V AC
DC-DC Converter 110V DC
Resistor 100/110V AC/DC
Panel Thickness 0.8 to 6 Mounting Clip SLC-3K1 • On flasher type, Terminals X1 and X2 are positive and
negative poles, respectively.
M3.5 Terminal Screws
• On DC-DC converter type, Terminals X1 and X2 are
positive and negative poles, respectively.
• Resistance
7.2 kΩ, 4W
40
11
56 6 87.5 19
40
11
18 20 6 68.1 20
18
SLC40 Series Combination Display Lights
Fingersafe,
Arrows indicate SLCN-JP44 SLCN-JP44
Spring-up Terminal —
access direction for SLCN-JP45 SLCN-JP45
(Note 1)
wiring terminals.
Others SLC-JP40 SLC-JP41 SLC-JP42
Note 1: Fingersafe, spring-up terminals are used in one-color full
Fingersafe, Spring-up Other terminals illuminated (12, 24V AC/DC, 100/110, 200/220V AC, 110V DC).
Terminal • For Type C, jumpers can be used on Terminal X1 only as shown
below.
(Flasher Connection Diagram)
• When using Type C only
Direction
• When using Type C and Two-color alternate
X1
Positive LED Module Vertical SLC-JP40
Flasher Horizontal SLC-JP41
Circuit
Note: Jumpers cannot be used when using Type C and fingersafe spring-
Negative up terminals.
X2
X1
Positive
X2
C
LED When using three windows
Negative Using two SLCN-JP45 jumpers
Module
X2
Negative
C
Red (R)
Negative LED Module
X1 Common
X2 X1
X3 LSRD
X2 Upper
LSRD
X3 Lower
19
SLC40 Series Combination Display Lights
05 05 • Type H
Full Voltage Flasher (A, G, R, Y) DF 24V DC ±10% 2 H Blue S
40 × 80 mm
06 06 100/110V AC ±10% 1 Yellow Y
07 07 Transformer (A, G, R, Y) TD
200/220V AC ±10% 2 Red/Green RG
08 100/110V AC ±10% 1
09 Transformer (PW, S) TDA • Type L
200/220V AC ±10% 2 L • Color Screen
40 × 120 mm
10 DC-DC Converter (A, G, R, Y) CD 110V DC (90 to 140V DC) 1
Combination
(Code)
11 Resistor (A, G, R, Y) RN 100/110V AC/DC ±10% 1 When color display is
12 One-color Full × 2 split required at power off,
BA9S/13
Lamp
LED
window (Type C) (A, G, Base DP 24V AC/DC ±10% (LSRD-2) 2 order color screens. For
13 R, Y) • Type V details, see page 31.
14 V
80 × 40 mm
Amber TA
15
The following color/voltage selections are also available. Green TG
16
Operating Voltage (Built-in Lamp) Red TR
17 Unit
(Code)
Blue TS
18 Full Voltage w/Check Terminal DHMA 24V DC ±10% 2 Yellow TY
(PW, S) • Type V
19 G
Full Voltage Flasher DFA 24V AC/DC ±10% 2 80 × 80 mm • Gray Lens Combination
20 (PW, S) (Code)
21 115V AC ±10% 11 Amber SA
22 120V AC ±10% 12 Green SG
23 230V AC ±10% 23 Pure White SPW
• Type C
24 Transformer (A, G, R, Y) TD 240V AC ±10% 24 C
(20 × 40 mm) × 2 Red SR
380V AC ±10% 38 Blue SS
400/440V AC ±10% 4 Yellow SY
LED Unit
only) BA9S/13
One-color Full window Base
(Type C)
DPC 24V AC/DC ±10% (LSRD-2) 2
(combination of PW,
S and A, G, R, Y)
20
SLC40 Series Combination Display Lights
• Type C (split-window)
Type F equivalent: 1 window
Row (1), Column (1)
[Designation Examples]
Ex. 1 SLC40 Series LED illuminated units • When more than one color is
in one color. required for LED.
Type F, 20 windows • When a particular arrangement of
color screen is required.
Columns Color screen: Type F, 20 windows Specify each color code on the
4 5 R (20) = 20 specification sheet.
2 3
1 Columns
Color Code
• When color screen is
1 Rows 1 2 3 4 5 6
Rows required, specify the color
2 screen code. R R G G G
1 +
3 Ex.
Color Code Y Y Y Y Y +
4 2
Color Screen Code A A S S S
3 +
Ex. 2 SLC40 Series 4
A A S S S +
Type H, 9 windows (Type F equivalent: 3 rows by 6 columns) 5 + + + + + +
Columns Color screen: Type H, 9 windows Specify each color code on the
G (9) = 9 specification sheet.
4 5 6
2 3 Columns
1 Color Code
• When color screen is
1 2 3 4 5 6 7
Rows 1 required, specify the color
Rows
2 screen code. PW R R +
1
3 Ex. PW R R
Color Code 2 +
Color Screen Code PW G G +
3
4 + + + + + + +
Ex. 3 SLC40 Series (Type F, 12 windows)
When ordering a combination of units with different operating voltages, specify Part No. as follows.
Type F, 12 windows, Full voltage 24V AC/DC 8 Transformer 100/110V AC 4 Columns
Rows 1 2 3 4 5
1 + DD2
2 +
SLC40N-0304- DD 2 FB(8) + TD 1 FB(4) - R(12) 3 +
TD1
+ + + + +
4
Specify the position of the units and each voltage on the specification sheet.
Ex. 4 When ordering a combination of units with different illumination colors, specify Part No. as follows.
Rows
Columns
Example: Full voltage LED illuminated 24V AC/DC, Red (6), Pure White (2) Specify the position of the units Color Code
and each color code on the 1 2 3 4 5
SLC40N-0204-DD2FB(6) + DDA2FB(2) - R(6)PW(2) specification sheet. PW R R R
+
1
Red Pure White Designation 2
PW R R R
+
Red: 6, Pure White: 2
+ + + + +
Columns
Ex. 5 When ordering a combination of units with different illumination colors for four windows of type C, Color Code
21
SLC30/40 Series Combination Display Lights Accessories
Terminal Cover
Terminal Cover
Type C (half-type)
Applicable +2.5 mm
one color Full × 2
One-color Full
Applicable +4.7 mm
w/Check Terminal
Type C (half-type)
Applicable +3 mm
one color Full × 2
Weight
Approximate weight of SLC combination display lights can be calculated in the formula below.
Weight = A × (No. of Rows + No. of Columns) + B × No. of Windows
Type F equivalent Type F equivalent
Frame Weight Display Weight
22
SLC30/40 Series Combination Display Lights Accessories
Clear Plate
SLC40N SLCN-4ST-F2 SLCN-4ST-F2 1
(supplied with the spot illumination type SLC)
Lens Frame Clear Plate
SLC30N SLDN-3C-FW-ST1 SLDN-3C-FW-ST1 1
White Screen for Spot Illumination Matte Surface
SLC40N SLDN-4PF-FW-ST1 SLDN-4PF-FW-ST1 1
Tool Accessories
Package
Name & Shape Material Part No. Ordering No. Remarks
Quantity
Lamp Holder Tool Used for replacing LED lamps (LFTD) for SLC30
ø6.6
Type C (Split-window).
Rubber OR-44 OR-44 1
ø7.5
60
ø11.6
ø14
Rubber OR-55 OR-55 1
59
LED Unit Removal Tool Used for removing the LED unit for the SLC30/40
series.
Metal MT-101 MT-101 1
60
Lens Unit Removal Tool Used for removing the lens unit.
Rubber
MT-S01 MT-S01 1
(Ring: metal)
Note: For insertion order into SLC frames or markings, see operating instructions on page 31 and 32.
23
SLC30/40 Series Combination Display Lights Accessories
Replacement Parts
Lens
Name & Shape Description Series Applicable Window Dimensions (mm) Material Part No.
F 28H × 28W × 2.8t SLC-3LF
H and V 28H × 58W × 2.8t SLC-3LH
SLC30 L 28H × 88W × 2.8t SLC-3LL
G 58H × 58W × 2.8t SLC-3LG
C 13H × 28W × 2.8t SLC-3LC
Clear
F 36.8H × 36.8W × 2.8t SLC-4LF
H and V 36.8H × 76.8W × 2.8t SLC-4LH
SLC40 L 36.8H × 116.8W × 2.8t SLC-4LL
G 76.8H × 76.8W × 2.8t SLC-4LG
C 16.8H × 36.8W × 2.8t SLC-4LC
Acrylic
F 28H × 28W × 2.8t SLC-3LF-M
H and V 28H × 58W × 2.8t SLC-3LH-M
SLC30 L 28H × 88W × 2.8t SLC-3LL-M
G 58H × 58W × 2.8t SLC-3LG-M
C 13H × 28W × 2.8t SLC-3LC-M
Gray
F 36.8H × 36.8W × 2.8t SLC-4LF-M
H and V 36.8H × 76.8W × 2.8t SLC-4LH-M
SLC40 L 36.8H × 116.8W × 2.8t SLC-4LL-M
G 76.8H × 76.8W × 2.8t SLC-4LG-M
C 16.8H × 36.8W × 2.8t SLC-4LC-M
Lens Frame
Shape Series Applicable Window Material Part No.
F SLC-3WF-BL
H ABS SLC-3WH-BL
H (split-window) (Note) SLC-3WH2-BL
SLC30 L PC SLC-3WL-BL
V SLC-3WV-BL
G SLC-3WG-BL
C ABS SLC-3WC-BL
F SLC-4WF-BL
H SLC-4WH-BL
L PC SLC-4WL-BL
SLC40
V SLC-4WV-BL
G ABS SLC-4WG-BL
C SLC-4WC-BL
LED Units
Operating
Series & Shape Illumination Rated Current Part No. Ordering No. Color Code
Voltage
SLC30
6V AC/DC Amber, green, red, yellow:12mA SLDN-36M-∗ SLDN-36M-∗T
One color
12V AC/DC Amber, green, red, yellow: 12mA SLDN-31M-∗ SLDN-31M-∗T
full
Specify a color
Amber, red: 12mA code in place
24V AC/DC SLDN-32M-∗ SLDN-32M-∗T of ∗ in the Part
Blue, green, pure white, yellow: 11mA
No.
Two-color
alternate
24V DC Red: 12mA/green: 11mA SLDN-32MW-RG SLDN-32MW-RGT A (amber)
Weight: approx. 4.3g
G (green)
SLC40 PW (pure
One color Amber, blue, green, pure white, red, white)
24V AC/DC SLCN-42M-∗ SLCN-42M-∗T R (red)
full yellow: 15mA
S (blue)
Y (yellow)
Two-color
alternate
24V AC/DC Red: 15mA/green: 15mA SLCN-42MW-RG SLCN-42MW-RGT
Weight: approx. 9.2g
Note: Blue (S) and PW (pure white) are 24V AC/DC only
24
SLC30/40 Series Combination Display Lights Accessories
Replacement Parts
LED Units for Spot Illumination
Rated Voltage
Series & Shape Rated Current Part No. Ordering No. Color Code
(AC: 50/60 Hz)
SLC30
• Used with SLCN-ST-* spot illumination kit. The spot color is same as illumination surface.
LED Lamps
Operating Current Draw Illumination Package
Shape Part No. Ordering No. Base
Voltage DC Rating AC Rating Color Quantity
LFTD Lamp (SLC30) LFTD-5∗ 1
8 mA (except S)
5V DC — LFTD-5∗
7 mA (S) LFTD-5∗PN10 10
Specify a color code in
9 mA 1
7 mA (except S) LFTD-6∗ place of ∗ in the Part
6V AC/DC (A, R, S, Y) LFTD-6∗
6 mA (S) No.
10 mA (G, PW) LFTD-6∗PN10 A (amber) 10 SX6S/8
G (green) 1 × 5.4
8 mA (except S) 9 mA (except S) LFTD-1∗
12V AC/DC LFTD-1∗ PW (pure white)
ø6.2
14.5
7 mA (S) 8 mA (S) LFTD-1∗PN10 R (red) 10
S (blue)
8 mA (except S) 9 mA (except S) LFTD-2∗ 1
24V AC/DC LFTD-2∗
7 mA (S) 8 mA (S) LFTD-2∗PN10 10
LSRD Lamp (SLC40)
LSRD-2 1
LSRD-2PN10 10
• Only one color is available for LSRD so there are no codes to specify the color in the part no.
25
SLC30/40 Series Combination Display Lights Accessories
SLC30 SLDN-3DH
One-color Full
SLC40 SLDN-4DH
Transformer Unit
Primary Voltage
Shape Series Illumination Applicable LED Unit Part No.
(50/60 Hz)
100/110V AC SLDN-3TH1
SLC30 SLDN-32M-*
200/220V AC SLDN-3TH2
LED
100/110V AC SLDN-4TH1
SLC40 SLCN-42M-*
200/220V AC SLDN-4TH2
SEC. 4
2
200/220V AC 0.5W, 24V TWR522 table
JAPAN
PRI.
22
30
Secondary Side Primary
below. Side
1
400/440V AC 0.5W, 24V TWR542
Mounting Hole 40
2-ø3.3 48
• Terminal cover (Part No. TWR-VL3) is supplied as standard.
52
45.5
SLDN-32M-∗ One-color full (one unit per transformer)
LED Unit
5
26
SLC30/40 Series Combination Display Lights Accessories
11.6
A A A t = 0.5
Part No. L A
For SLC40
SLCN-JP44 SLCN-JP44PN10 SLCN-JP34 97.8 30
Jumper for Terminal X1, X2
fingersafe, SLCN-JP44 128 40
(Supplied)
Spring-up
Terminal Ring Terminal (for 2 windows) ø4.4
4.9
Rated Current: 3A L 3.2
For SLC30
SLCN-JP35 SLCN-JP35PN10
Terminal X1, X2
11.6
A t = 0.5
Part No. L A
For SLC40
SLCN-JP45 SLCN-JP45PN10 SLCN-JP35 37.8 30
Terminal X1, X2
SLCN-JP45 48 40
(Supplied)
Spade Terminal
L
Rated Current: 3A
For SLC30 A
SLC-JP30 SLC-JP30PN10
Terminal X1
7.7
4 t = 0.5
Terminal X2
40
t = 0.5
ø4.4
Ring Terminal L
Rated Current: 3A For SLC30 ø3.8
Terminal C (check A
SLC-JP32 SLC-JP32PN10
terminal & 2-color
alternate)
6
t = 0.5
B
Mounting Clips
36 2
Used for fastening SLC
10
M3
(Supplied)
27
SLC30/40 Series Combination Display Lights Instructions
Safety Precautions
• Turn off the power to the SLC units before installation, removal, • For wiring, use wires of a proper size to meet the voltage and
wiring, maintenance, or inspection. Before removing the LED current requirements and tighten the terminal screws to the
units, make sure that power is turned off. Failure to turn off the tightening torque shown below. Loose terminal screws may
power may cause an electrical shock, create fire hazards, or cause excessive heating, resulting in fire hazards.
damage of LED units or lamps. Do not use the SLC units without • Do not install or operate the SLC units where the SLC units are
the lens, otherwise ingress of foreign objects may cause short subjected to direct sunlight. Excessive heating may create fire
circuit, and LED units may be damaged resulting in the deterio- hazards or damage the SLC units.
ration of LED brightness or no lighting.
• When replacing LED units or LED lamps, use IDEC products.
• When lighting the SLC units continuously, observe the condi-
tions described below. If the limits are exceeded, the SLC units
may heat up and create fie hazards or damage the SLC units.
Operating Instructions
Notes for Continuous Lighting <Storage and Handling>
Up to 10 SLC units (Type F equivalent) can be lit continuously. • Do not use the SLC where it is subjected to condensation
When more units are mounted, consider the following restrictions. caused by extreme temperature change.
Full voltage • Do not use chemicals such as alcohol that degrade the property
of acrylic.
• Do not light more than 40% of the SLC units continuously, and
light the units in a checker pattern.
• When more than 40% of the units are lit continuously, limit the <Operating Instructions>
lighting duration to 40 minutes. Before lighting the units again, • The illumination color may change depending on the decreasing
ensure that all units have cooled down. brightness of LED, along with the period of use.
• When using 2-color alternate units, do not light the two colors • The SLC can be used indoors only. Do not use outdoors.
simultaneously.
Transformer and DC-DC converter
• Light the units in a flashing or checker pattern.
When using the SLC units in other conditions, contact IDEC.
28
SLC30/40 Series Combination Display Lights Instructions
Operating Instructions
When Using Blue and Green LED Units Notes for Using LED Units
When replacing LED units, avoid ESD to the LED pins, otherwise Countermeasures against dim lighting
the internal LED elements may become damaged. The SLC units contain a provision against dim lighting due to leak
age current. If the LED unit appears to be dimly lit due to induced
Metal Pins current from nearby AC lines, take appropriate countermeasures
as described below.
[Sample Circuit]
AC Line
~ ~ Transformer
C
Type LED
R
Ie
Protection
Precautions for Noise Ie: Induced Current
Circuit
SLC30 Series
• SLDN-36M-∗ (6V AC/DC) •X2
SLDN-36M-W (6V AC/DC) • S X2
LDN-31M-W (12V AC/DC) X2
29
SLC30/40 Series Combination Display Lights Instructions
Operating Instructions
Type F, H, H2, L, V, G
Marking Plate/
Display Color
Light Source Color Screen Lens ON Color (Color Code) OFF Color
Type
(Note 1) (Note 2)
Matte Surface
Standard amber (A), blue (S), green (G), pure white (PW) (Type F only),
red (R), yellow (Y)
(using clear red/green (two-color alternate) (RG) (no spot illumination
White
lens) SLC30 SLC40 for red/green two-color alternate)
LED unit clear / white clear lens
Matte Surface
amber (TA), blue (TS), green (TG), red (TR), yellow (TY)
SLC30 SLC40
LED unit white / color clear lens Same as
Color Screen Matte Surface ON color
Type C (split-window)
Marking Plate/
Display Color
Light Source Color Screen Lens ON Color (Color Code) OFF Color
Type
(Note 1) (Note 2)
Matte Surface
amber (A), blue (S), green (G), red (R), yellow (Y)
SLC30 SLC40
Standard LED lamp color / white clear lens
(using clear Matte Surface
White
lens)
pure white (PW)
SLC30 SLC40
LED lamp white / clear clear lens
Matte Surface
30
SLC30/40 Series Combination Display Lights Instructions
5.5 5.5
Spot illumination ø7
LED unit
ø7
Clear marking
plate White screen
25.4
1.0 1.0
0.8 0.8
1.0 1.0
Type F spot illumination kit 25.4
(Supplied with the supot illumination type SLC.
See page H-27 for details.)
For engraving area, see page 7.
Type F Type F
Marking on Films Type F Spot F
Type Illumination
In addition to white color screens or clear marking plates, legends Spot Illumination
35.8
SLC40 35.8 11
can be engraved on thin marking films on Type F windows. Two 35.8
sheets of 0.1-mm-thick films or one sheet of 0.2-mm-thick films is SLC40 35.8 11
applicable. Marking films are not supplied with the SLC units and
must be prepared by the user. ø7
8.4 8.4
ø7
Dimensions
SLC30N: 27 × 27 mm
SLC40N: 35.8 × 35.8 mm
34.1
Film Material
1.0 1.0
0.8 0.8
34.1
1.0 1.0
Polyester is recommended.
31
SLC30/40 Series Combination Display Lights Instructions
Operating Instructions
Removing the Windows
SLC30 Series
To remove the display window, insert the tip of a flat screwdriver SLC30 Series
into the slot on the bottom of the lens frame, and press down
lightly on the screwdriver as shown.
For types G and V, do not put excessive force to remove one
latch while pressing the other latch on the opposite side.
SLC40 Series (Extensible Windows)
The extensible window, featured on all SLC40 series units
except Types C, G, and L, can be removed simply by pulling the
upper portion out of the housing. For Types C, G, and L, insert
the tip of a flat screwdriver into the slot on the bottom of he lens
frame, and press up lightly.
When installing Type C windows, face the retaining latch with SLC40 Series
TOP marking upward.
All windows are shipped with the window retracted. After the
windows are installed in a panel, they can be extended as
required starting from the lowest row to the top row. Beware of
the orientation when installing the units. When transporting the
units, hold all windows in the retracted position.
32
SLC30/40 Series Combination Display Lights Instructions
Recesses
SLC30 Series Latches Latches
Recesses
(Not
Recesses
extensible)
Latches Latch
Latches
Latches
SLC40 Series Latch
(Extensible
Windows)
Not Extensible
Type G: Not extensible Not Extensible
Retaining Lens 2
Replacing the LED Unit Projections 3
Ensure that power to the display lights has been turned off before removing the LED unit. 4
[Removal] [Installation]
Use the LED unit removal tool (MT-101) to TOP Side The LED unit has an orientation. To install TOP Side
pull out the LED unit. For SLC30 units, the LED unit, place the metal pins on the
pinch the top and bottom sides of the unit. LED unit to fit into the receptacles in the
For SLC40 units, pinch the right and left housing, and insert the LED unit.
sides of the unit.
Amber A Amber dot Pure
PW P
Latches
White
Blue S Blue dot
Latches
Red/
RG —
Green
Note: Yellow (Y) LED unit uses a pure white LED unit with a yellow
filter on the LED.
33
SLC30/40 Series Combination Display Lights Instructions
Insert completely.
Insert
Align the insertion guides of the lamp holder with the grooves in
the SLC unit. Push the lamp lightly and turn clockwise to install.
SLC40, Type C
Lamps can be replaced easily by using the lamp holder tool
OR-55. When removing the lamp, reflector does not have to be
removed.
Installation on Panel
Insert the units into a panel cut-out from the front, and install the mounting clips supplied with the units
from the back as shown below. Apply loctite on the screws to prevent loosening. The number of
mounting screws varies with the number of windows.
Tighten the screws to a torque of 0.39 N·m to 0.49 N·m.
1 to 2
(Note)
4 to 6
7 to 10
1 to 2 2 4 (6) 6 (8) 8 10
3 to 6 4 (6) 6 (8) 8 (10) 10 (12) 12 (14)
7 to 10 6 (8) 8 (10) 10 (12) 12 14
Note: Numbers in ( ) show the number of mounting clips required
for transformer, resistor, flicker, and DC-DC converter.
34
SLC30/40 Series Combination Display Lights Instructions
Rows 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
4
40 Series
7
30 Series
10
35
SLC30 Series Combination Display with Control Units
Combination of display lights and control units reduce labor of switch installation and
minimizes installation space.
Switch for lamp test, external switch for system display can be integrated into the frame of
combination display lights.
• Various control units can be installed in the window
frame, with or without SLC units.
• Panel space can be reduced.
• Labor and time to install switches can be reduced.
• Flexibility of panel design is maximized.
• Up to 30 windows (3 rows × 10 columns) can be used.
Selector Switch (Round w/Square Bezel) Gold contact: 125V AC/0.1A, 30V DC/0.1A
(resistive load)
Key Selector Switch (Round w/Square Bezel) Operating
Silver contact: 125V AC/3A, 250V AC/2A
• Contact: DPDT (gold or silver) Voltage/Current
30V DC/2A, 125V DC/0.4A
• Operation: 2 or 3-position, maintained (resistive load)
C C C C
45° 3-position Left Contact Right Contact Left Contact Right Contact Left Contact Right Contact
NO NC NO NC NO NC NO NC NO NC NO NC
C
L R
C C C C C C
36
SLC30 Series Combination Display with Control Units
L 6 55.5 30
21
14
30
30
7.6
7.6
Panel thickness:
30 0.8 to 6 M3 Terminal Screw 8.2 8.2
6.3 30
A 66.7 Unit A
Illuminated Pushbutton 6.3
Pushbutton 6.3
No. of Columns 1 2 3 4 5 6 7 8 9 10 (With teminal cover: 68.1) Selector Switch 14.8
L 42 72 102 132 162 192 222 252 282 312 Key Selector Switch 34.3
Operating Instructions
1 row: 35 1. When using the insulation terminal cover (LW-VL2M) for the
2 rows: 65 control units
3 rows: 95
• Install the terminal cover on the SLC units before wiring. Ter-
minal covers cannot be installed after wiring.
• Ring crimping terminals cannot be installed when terminal
covers are used. Use spade terminals or wire directly.
2. Do not remove the operator part of control units from the
housing. Otherwise contacts may malfunction.
No. of
1 2 3 4 5 6 7 8 9 10 3. On key selector switches, do not attempt to remove the key
Columns
at any key retained position with excessive force (more than
M (mm) 35 65 95 125 155 185 215 245 275 305
approx. 70N). Otherwise the operator part detaches from the
housing, causing the contacts to malfunction.
4. Use a lamp holder tool (OR-55) when replacing lamps for
Panel Cut-out (Bottom View) control units.
Pushbutton 5. For wiring, use wires of a proper size to meet the voltage and
Selector Switch current requirements. Tighten the M3.5 terminal screws to a
SLC30 Illuminated Pushbutton
Key Selector Switch tightening torque shown below.
37
SLC30 Series Combination Display with Control Units
SLC30/40 Series Combination Display Lights with Control Units Specification Sheet
Date of Order
Customer
Address
Phone No.
Contact
Part No.
3
(Bottom Row)
Specification Notes
1. Use the specification diagram above for LED one-color Full (24V AC/DC) only. Upper
2. Control units can be mounted on the bottom row (the third row in the diagram above) only. Lower
Enter button or lens color code in the upper part and control unit code in the lower part
(see the table below for control unit code). Display lights can be specified on the bottom row.
3. Specify the TOP position (mounted onto the panel).
Rows Columns
Key Code A B C
SLC30N - 0 2 0 3 - DD 2 ML B 2-position L R L R L R L C R:
Maintained Key can be released from these positions.
SLC30 Series
No. of Windows
Key Code A B C D E G H
3-position L C R C C C
L C R L
C
R L
C
R L R L R L R
Maintained
Columns: 01 to 10
Rows: 01 to 03
38
Ordering Terms and Conditions
Thank you for using IDEC Products.
By purchasing products listed in our catalogs, datasheets, and the like (hereinafter referred to as “Catalogs”) you agree to be bound by these terms and conditions. Please read
and agree to the terms and conditions before placing your order.
Specifications and other descriptions in this brochure are subject to change without notice.