5572 Saf
5572 Saf
5572 Saf
1 - INTRODUCTION :
PROJECT NAME : Next PROJECT 2023 CUSTOMER : MOBILY
a) GENERAL
Site ID : 5572
Address : AL JUMUM
GPS Coordinates (WGS84 decimal degrees) 21.640238 °N 39.706745 °E
b) TOWER
Site Type : Macro
Shelter Type: Normal
Civil Model: 35m Tower
Pole/Tower Height : 35m
Building Height : N/A
c) Security
Security Guard at Site No
No of
Antennas
1 1 1
Antenna
Azimuth
30 120 330
Antenna
Height
35m 35m 35m
Electrical Tilt /
Mechanical BuiltIn/0 BuiltIn/0 BuiltIn/0
Tilt
Indoor 3m&1/2'' 3m&1/2'' 3m&1/2''
Jumper
Length & Type OD OD OD
Feeder Type /
Fiber
Fiber Fiber Fiber
Feeder
no's,Length 2&50m 2&50m 2&50m
or FO length
TMA (Yes/No) No No No
RET Cable
length
No No No
Diplexer/Triplex
er (Yes/No) with Yes (1) Yes (1) Yes (1)
Qty
RRUS Type
(if any)
1x2219 B8 1x2219 B8 1x2219 B8
Bracket Type
of RRUS
Rail Rail Rail
Source of
Power for Rectifier
RBS / RRUS
CB rating in
Amperes
100A
CB Type
(ABB, ABB
Emerson etc)
Site
Configuration
Ant. Sharing
900/1800/3G/LTE with U900/3G/FDD/L800
2.2 - Existing 3G System
3G 2100Mhz U900
# of Antennas 1 1 1 1 1 1
Antenna
Azimuth
30 120 330 30 120 330
Antenna
Height
35m 35m 35m 35m 35m 35m
Electrical Tilt /
Mechanical BuiltIn/0 BuiltIn/0 BuiltIn/0 BuiltIn/0 BuiltIn/0 BuiltIn/0
Tilt
Indoor 3m&1/2'' 3m&1/2'' 3m&1/2''
Jumper 3m&1/2'' 3m&1/2'' 3m&1/2''
Length & Type OD OD OD
Feeder Type /
Fiber
7/8'' 7/8'' 7/8'' Fiber Fiber Fiber
Feeder
no's,Length 2&42m 2&42m 2&42m 2&50m 2&50m 2&50m
or FO length
RET Cable
length
No No No No No No
Diplexer/Triplex
er (Yes/No) with Yes (1) Yes (1) Yes (1) Yes (1) Yes (1) Yes (1)
Qty
RRUS Type
(if any)
1xRUS B1 1xRUS B1 1xRUS B1 1x2219 B8 1x2219 B8 1x2219 B8
Bracket Type
of RRUS
No No No Rail Rail Rail
Source of
Power for Rectifier Rectifier
RBS / RRUS
CB rating in
Amperes
100A 100A
CB Type
(ABB, ABB ABB
Emerson etc)
Site
Configuration
Ant. Sharing
900/1800/3G/LTE with 2G/U900/FDD/L800 with 2G/3G/FDD/L800
2.3 - Existing 4G System
Antenna Type K84510866 K84510866 K84510866 AIR 6449 B41 AIR 6449 B41 AIR 6449 B41
# of Antennas 1 1 1 1 1 1
Antenna
Azimuth
30 120 330 30 120 330
Antenna
Height
35m 35m 35m 35m 35m 35m
Electrical Tilt /
Mechanical BuiltIn/0 BuiltIn/0 BuiltIn/0
Tilt
Indoor 3m&1/2'' 3m&1/2'' 3m&1/2''
Jumper
Length & Type OD OD OD
Feeder Type /
Fiber
Fiber Fiber Fiber Fiber Fiber Fiber
Feeder
no's,Length 1&50m 1&50m 1&50m 3&50m 3&50m 3&50m
or FO length
TMA (Yes/No) No No No
RET Cable
length
3m 3m 3m
Diplexer/Triplex
er (Yes/No) with Yes (1) Yes (1) Yes (1)
Qty
CB rating in
Amperes
100A 100A
CB Type
(ABB, ABB ABB
Emerson etc)
Site
Configuration
Ant. Sharing
900/1800/3G/LTE with 2G/U900/3G/L800 with 5G
2.4 - Existing 5G / L800 System
5G 5G L800
Antenna Type AIR 6449 B41 AIR 6449 B41 AIR 6449 B41 K84510866 K84510866 K84510866
# of Antennas 1 1 1 1 1 1
Antenna
Azimuth
30 120 330 30 120 330
Antenna
Height
35m 35m 35m 35m 35m 35m
Electrical Tilt /
Mechanical BuiltIn/0 BuiltIn/0 BuiltIn/0
Tilt
Indoor 3m&1/2'' 3m&1/2'' 3m&1/2''
Jumper
Length & Type OD OD OD
Feeder Type /
Fiber
Fiber Fiber Fiber Fiber Fiber Fiber
Feeder
no's,Length 3&50m 3&50m 3&50m 1&50m 1&50m 1&50m
or FO length
TMA (Yes/No) No No No
RET Cable
length
No No No
Diplexer/Triplex
er (Yes/No) with Yes (1) Yes (1) Yes (1)
Qty
RRUS Type
(if any)
AIR 6449 B41 AIR 6449 B41 AIR 6449 B41 1x2217 B20 1x2217 B20 1x2217 B20
Bracket Type
of RRUS
Pole Pole Pole Rail Rail Rail
Source of
Power for Rectifier Rectifier
RBS / RRUS
CB rating in
Amperes
100A 100A
CB Type
(ABB, ABB ABB
Emerson etc)
Site
Configuration
Ant. Sharing
900/1800/3G/LTE with TDD with 2G/U900/3G/FDD
3 - EXISTING POWER SYSTEM
3.1 - DC POWER SYSTEM
DC Power (-48V)
GENERATOR DUAL : No
GENERATOR SINGLE : No
No GENERATOR : Yes
Note
3.2 - AC POWER SYSTEM
Others
AC Power (220V)
Specify
SCECO POWER :
Fuse holder/Main
Circuit Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Note
4 - RF ENVIRONMENT DETAILS
Sector 1-Antenna installation environment(Face to the tower or pole to take photo for the antenna
installation environment)Full Tower view
Sector 1-Antenna installation environment(Face to the tower or pole to take photo for the antenna
installation environment)Zoomed view
Sector 2-Antenna installation environment(Face to the tower or pole to take photo for the antenna
installation environment)Full Tower view
Sector 2-Antenna installation environment(Face to the tower or pole to take photo for the antenna
installation environment)Zoomed view
Sector 3-Antenna installation environment(Face to the tower or pole to take photo for the antenna
installation environment)Full Tower view
Sector 3-Antenna installation environment(Face to the tower or pole to take photo for the antenna
installation environment)Zoomed view
Sector 4-Antenna installation environment(Face to the tower or pole to take photo for the antenna
installation environment)Full Tower view
Sector 4-Antenna installation environment(Face to the tower or pole to take photo for the antenna
installation environment)Zoomed view
5 - INDOOR AND OUTDOOR PICTURES
Existing Equipments - 3G
Existing Equipments - 4G
CB 1 2 3
No of CB
Used CB
Free CB
6 - TRANSMISSION DETAILS
No. Far End Ant. Diameter (m) Height (m.a.g.l) Azimuth to FE(deg)
1
2
3
4
5
6
7
8
Definition of Terms
MODEL :
Circuit Breaker No
ERS & its Location Yes 3xRadio 2219 B1 to be installed on existing Pole backside Ant in Vertical Position
ERS System
2G 900 / W900 / L800 Antenna No Existing K84510866 Ant to be used with existing 3xDiplexers(B8/B20)
LTE 800 Antenna No Existing K84510866 Ant to be used with existing 3xDiplexers(B8/B20)
LTE FDD 2100 / 3G 2100 No Existing K84510866 Ant to be used with existing 3xDiplexers(B1/B3)
Antenna System
LTE FDD 1800 / 2G 1800 No Existing K84510866 Ant to be used with existing 3xDiplexers(B1/B3)
DCDP No
MODEL
SCOPE
Circuit Breaker
Bracket Type
ERS System
Circuit Breaker
Antenna System
5G Antenna
DCDP
Additional
Information
MAIN UNIT : PROPOSAL
Sector A : Antenna Type & Location Existing K84510866 Ant to be used with existing 1xDiplexers(B1/B3)
Sector B : Antenna Type & Location Existing K84510866 Ant to be used with existing 1xDiplexers(B1/B3)
Sector C : Antenna Type & Location Existing K84510866 Ant to be used with existing 1xDiplexers(B1/B3)
PROPOSED TECHNOLOGY
PROPOSED TECHNOLOGY
Req RET cable
Sector D : Proposed Radio Type and Location
MODEL
PROPOSED TECHNOLOGY
PROPOSED TECHNOLOGY
Req RET cable
Sector A : Proposed Radio Type and Location
ANTENNA- RRU : PROPOSALS
PROPOSED TECHNOLOGY
PROPOSED TECHNOLOGY
Req RET cable
Sector B : Proposed Radio Type and Location
ANTENNA- RRU : PROPOSALS
PROPOSED TECHNOLOGY
PROPOSED TECHNOLOGY
Req RET cable
Sector C : Proposed Radio Type and Location
ANTENNA- RRU : PROPOSALS
PROPOSED TECHNOLOGY
PROPOSED TECHNOLOGY
Req RET cable
Sector D : Proposed Radio Type and Location
MODEL
PROPOSED TECHNOLOGY
PROPOSED TECHNOLOGY
Req RET cable
Sector A : Proposed Radio Type and Location
ANTENNA- RRU : PROPOSALS
PROPOSED TECHNOLOGY
PROPOSED TECHNOLOGY
Req RET cable
Sector B : Proposed Radio Type and Location
ANTENNA- RRU : PROPOSALS
PROPOSED TECHNOLOGY
PROPOSED TECHNOLOGY
Req RET cable
Sector C : Proposed Radio Type and Location
ANTENNA- RRU : PROPOSALS
PROPOSED TECHNOLOGY
PROPOSED TECHNOLOGY
Req RET cable
Sector D : Proposed Radio Type and Location
POWER : PROPOSAL
New MDB / Circuit Breaker Proposed Location Need new 3x25A CB ABB in existing Rectifier
Battery : PROPOSAL
Existing cable tray to be used , And arrange old power Fiber routing to make space for New
Cable Tray Location & Space Availability for Fiber and Power
5G Fiber and DC
Clamps
MODEL
ITEMS TO BE DISMANTLED
SCOPE 0
ITEMS TO BE DISMANTLED
RF ENVIRONMENT DETAILS
Location and Panoramic Analysis
Panoramic Pictures - 0 Degree
GPS Coordinates
SITE ACCESS
Site and Road Access Pictures
Site ID: 5572
City: AL JUMUM
Technology Activity
2G (900Mhz) No Change
2G (1800Mhz) No
3G (U900) No Change
Height 35 35 35 - - - - - 35 35 35 - 35 35 35 - 35 35 35 - 35 35 35 - 35 35 35 - 35 35 35 - 35 35 35 -
M/E-Tilt 0/4 0/4 0/4 - - - - - 0/4 0/4 0/4 - 0/4 0/4 0/4 - 0/4 0/4 0/4 - 0/4 0/4 0/4 - 0/4 0/4 0/4 - 0/4 0/4 0/4 - 0/4 0/4 0/4 -
RET Yes Yes Yes - - - - - Yes Yes Yes - Yes Yes Yes - Yes Yes Yes - Yes Yes Yes - Yes Yes Yes - - - - - -
TMA No No No - - - - - No No No - No No No - No No No - No No No - No No No - - - - - -
Diplexer / Qty Exi/1 Exi/1 Exi/1 - - - - - Exi/1 Exi/1 Exi/1 - Exi/1 Exi/1 Exi/1 - Exi/1 Exi/1 Exi/1 - Exi/1 Exi/1 Exi/1 - Exi/1 Exi/1 Exi/1 - - - - - -
Feeder Type 1/2" 1/2" 1/2" - - - - - 1/2" 1/2" 1/2" - 1/2" 1/2" 1/2" - 1/2" 1/2" 1/2" - 1/2" 1/2" 1/2" - 1/2" 1/2" 1/2" - - - - - -
Feeder Length(m) 3 3 3 - - - - - 3 3 3 - 3 3 3 - 3 3 3 - 3 3 3 - 3 3 3 - - - - - -
Feeder Loss 0.5 0.5 0.5 - - - - - 0.5 0.5 0.5 - 0.9 0.9 0.9 - 0.6 0.6 0.6 - 0.7 0.7 0.7 - 0.9 0.9 0.9 - - - - - -
Dl/Ul Attenuation 5 5 5 - - - - - 5 5 5 9 9 9 - 6 6 6 - 7 7 7 - 9 9 9 - - - - - -
Dl/Ul Feeder Delay 174 174 174 - - - - - 17.4 17.4 17.4 - 18.4 18.4 18.4 - 17.4 17.4 17.4 - 17.37 17.37 17.37 - 18.4 18.4 18.4 - - - - - -
Technology G900 G1800 U900 U2100 FDD800 FDD1800 FDD2100 TDD2600 5G
Sector A B C D A B C D A B C D A B C D A B C D A B C D A B C D A B C D A B C D
Cabinet Type / Qty 1x 6201
RF Module Qty/ Typ 3x 2219 [B8] [MM] - 3x 2219 [B8] [MM] 3x 2219 [B1][MM] 3x 2217 [B20] 3x 2219 [B3] + 3x A3 [B3] 3x 2219 [B1][MM] 3x AIR6449[B41][MM]
Signature
120W( 120W( 120W(
Power 40W 40W 40W
30 30 30 - - - - - 40 40 40 - 40 40 40 - 2x40 2x40 2x40 - 2x60 2x60 2x60 - 2x40 2x40 2x40 - - 80 80 80 -
each each each
carrier) carrier) carrier)
21-Sep-23
21-Sep-23
CE (DL/UL) - 2 HUP 3 HUP 18 MIMO Layer 12 MIMO Layer
BSS / EA 101
Mohammed Abualqumboz
1 1 1
Mehmood Bashwar
Salem AlMasri
5572-11C/12C/13C
5572-11A/12A/13A
5572-11B/12B/13B
5572-03C
5572-01C
5572-02C
5572-52C
5572-03A
5572-03B
5572-01A
5572-01B
5572-02A
5572-02B
5572-52A
5572-52B
5572C
5572K
5572A
5572B
55721
55722
55723
5572L
5572J
Cell ID
-
-
Scope 3x2219B1+dismantle 3xRUS 01 B1
Ericsson Approval
Ericsson Design
Mobily Approval
Comments