0% found this document useful (0 votes)
17 views

Tutorial 04 - Solution

Uploaded by

ritikkbhatia2000
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
17 views

Tutorial 04 - Solution

Uploaded by

ritikkbhatia2000
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 8
University of Waterloo CIVE 495/700 - Fall 2023 Tutorial #4 Problem 1 Use the formulation in 086 to find the moment capacity, shear strength, and bending stiffness, per meter width of the floor of a conventional joist system using 2x10 SPF No.1/No.2 joists spaced at 300mm o/c. Assume dry service conditions, no treatment, normal load duration, and standard light wood framing construction. Confirm your answer with the WDM tables. Moment Capacity (M_) Fromcl6.53.4 —» M, = BASK AKL 2-04 Po= Lok ky len ke = CISC = IGS mpe for (1% ThA Ky= | T&IC Kp= | 75.1 Kr= | TGII Ky= 14 TID case 2 Kee |. | 763 Ke | = cles.3.23 a. 235 _ A. Fe - ore bs 2 2. s= bd tenes) = 34475 ¥ mmé* 6 % b Me = Co. 9(6-S9(344789) (LDC) = STLiwm pergost (S2DC 10.3) = MMMM pe, meter won Shear Capacity ( ¥, From C1.6.5.4.3. —> Ve = © Fy A/a A Kev = Oo.4 me Mkpku eles = (SMI = 2.1 he 1S Th Kye | ThIO Ko= | TS. Kr= | TEAL Ka= LG ThA2 Kp= LA TOR An= By = (38)(235) = 8430 mm" Ve = (0.9L ASSIS = 12.4 kw per gore CI2.4)(Yo.3) = Gingike per meter wielth Bending Stiffness (E./) I= bod _ 12 12 Es= Ekser = 4500 E= 4500 Thy ExT = (9500)(4i1K 108) = 340% 10% Went per yoret (S238Y SG. 10 mo (340 x10°V(/0.3) = IBOOKIO" Simm per meter width Confirm with WDM Tables cose 2 (Noto? FIL 38x89 | 0768 655 one sexe [att 741 404 sext40 | 156 849 ne sextee | 232 957 aa gexz3s | 3.48 nz 187 138x285 | 466, 124 73 Homie sexe9 | o.8sd 552 773 sexta | 422 624 873 sext4o | 472 745 100 38 x 184 805 113 938x235, 943 132 38x 286 104 148 ‘SPF 38x89 87 724 sexta | 13 5.85 aro sextao | 185 670 9.38 sextee | 273, 755 108 38x 235, 4.09 884 We tee Ve 138x286 | 550 978 137 Northern 38x89 | 0.583, 448 628 sexta — | ogee 507 7.10 sex140 | 1.19 581 ans 3Bx184 | 176 18 138x235 | 2.63 398x286 | 3.54 ne (18 For Case 1 System muttiply single member M, and V, valves by 1.10. per gore Problem 2 Design a solid swan &xd beam such that it supports a live load of'@+kPa and a dead load of 1ekPa. The beam is cantilevered overtop of the last column (shown below). The beam is D.Fir SS and supports Sam long joists on either side, Due to the brittle ceiling material used, the transient deflection is limited to L/400 and the total deflection to /300 for the supported section and 1/200 and 1/150 for the cantilever section. You may ignore load patterning and assume that the beam is laterally braced at the columns. Calculate Loading 25D t+ ISL = 128(D + S08) = 5.15 Kee tu = 3am W > (5.15903) = 17.25 kuim Mt = w (Lta)*(L- a)* = 17.25 (6+2)7(b-2)* = GEST, oH ()()* = = (25)QY = S4SeKuR L L Ve = moxLv,, Va, Val = SrS es Vor Wy (2-04) = Yous al Va = Wa = 34.5 ks Vat bE (e408) = 515k Beam Teves pg 444 Use WDM to Estimate Size DF 191x191 191x241 191 x 202 191 x 343 191x994 Hem-Fir 191x191 191 x241 191 x 292 191x349 191x304 SPF 191x191, 191x241 Northern 191x191 191x241 Check Bending Resistance My = OPSkake O= 0.4 Fyre Soltalatenir = 14. Smpa fo= 149.5 TE Kp= | TS-1 Ke= | TOIL TIO Ke | TGA Pek 141x344 tt 7m mw om ea wo 1m a ™ ‘a mt 18 6 we s= sa 2 tatisas = U4YILTS mam? Ky= O-% TENS : a. 304. Pee Rye en ee 2\ 2s ke = ke Met = Wem = (o Ua. Sy(4aU ETO. = THETA Check > Mr? § Me* Ben Ma” TEAS TH US Check Shear Resistance We = OFv2An kev o= O.4 Fy= 15 An= Pro = CAN34D = 75254 mm* Ve = CoA CLSDCBIC 75254) (0. = SHH > STB uo Check Bending Stiffness je BOP. LANISAAY 473.5 x 1b mm 12 (2 E,= |2O00 mpw E= 12000 —> 766 EgI = (12000)(473.5 4104) = UhbaReO Som" Check Deflections | — Equchors From Se Ju bom token, pg 44 + L & Transient W = Lbs =(SD)> Tsim 2 4200 / WX, (Goth L? + botx, - ont + ¥*) = GEG EL Total Leb FL We (DL + LYE) = 2 bam X= LD La (Hoth - LP + botx,- Got +X) = Feed 6 L/1S0 J 24EL Betucen Supports. Transient WEG KX FB wad Q=G we (A4- 2084 ed Zot s tot) = asim ¢ Lyuoo / DMETL Total Welk X23 A=L L=& we (L420 = Doth e200) = Mam © LYz00 J4ELh

You might also like