General safety
Follow these rules to ensure general safety:
• Observe good housekeeping in the area of the machines during and after maintenance.
• When lifting any heavy object:
1. Make sure that you can stand safely without slipping.
2. Distribute the weight of the object equally between your feet.
3. Use a slow lifting force. Never move suddenly or twist when you attempt to lift.
4. Lift by standing or by pushing up with your leg muscles; this action removes the strain from the
muscles in your back. Do not attempt to lift any object that weighs more than 16 kg (35 lb) or that you
think is too heavy for you.
• Do not perform any action that causes hazards to the customer, or that makes the equipment unsafe.
• Before you start the machine, make sure that other service technicians and the customer's personnel are
not in a hazardous position.
• Place removed covers and other parts in a safe place, away from all personnel, while you are servicing the
machine.
• Keep your tool case away from walk areas so that other people will not trip over it.
• Do not wear loose clothing that can be trapped in the moving parts of a machine. Make sure that your
sleeves are fastened or rolled up above your elbows. If your hair is long, fasten it.
• Insert the ends of your necktie or scarf inside clothing or fasten it with a non-conductive clip, about 8
centimeters (3 inches) from the end.
• Do not wear jewelry, chains, metal-frame eyeglasses, or metal fasteners for your clothing.
Electrical safety
Observe the following rules when working on electrical equipment.
Important: Use only approved tools and test equipment. Some hand tools have handles covered with a soft
material that does not insulate you when working with live electrical currents.Many customers have, near
their equipment, rubber floor mats that contain small conductive fibers to decrease electrostatic discharges.
Do not use this type of mat to protect yourself from electrical shock.
• Find the room emergency power-off (EPO) switch, disconnecting switch, or electrical outlet. If an electrical
accident occurs, you can then operate the switch or unplug the power cord quickly.
• Do not work alone under hazardous conditions or near equipment that has hazardous voltages.
• Disconnect all power before:
– Performing a mechanical inspection
– Working near power supplies
Attention: Another person must be there to switch off the power, if necessary.
– Use only one hand when working with powered-on electrical equipment; keep the other hand in your
pocket or behind your back.
Attention: An electrical shock can occur only when there is a complete circuit. By observing the above
rule, you may prevent a current from passing through your body.
– When using testers, set the controls correctly and use the approved probe leads and accessories for
that tester.
– Stand on suitable rubber mats (obtained locally, if necessary) to insulate you from grounds such as
metal floor strips and machine frames.
Observe the special safety precautions when you work with very high voltages; Instructions for these
precautions are in the safety sections of maintenance information. Use extreme care when measuring high
voltages.
• Regularly inspect and maintain your electrical hand tools for safe operational condition.
• Do not use worn or broken tools and testers.
• Never assume that power has been disconnected from a circuit. First, check that it has been powered off.
• Always look carefully for possible hazards in your work area. Examples of these hazards are moist floors,
non-grounded power extension cables, power surges, and missing safety grounds.
• Do not touch live electrical circuits with the reflective surface of a plastic dental mirror. The surface is
conductive; such touching can cause personal injury and machine damage.
• Do not service the following parts with the power on when they are removed from their normal operating
places in a machine:
– Power supply units
– Pumps
– Blowers and fans
– Motor generators
– Similar units as listed above
This practice ensures correct grounding of the units.
• If an electrical accident occurs:
– Use caution; do not become a victim yourself.
– Switch off power.
– Send another person to get medical aid.
If any unsafe conditions are present, you must determine how serious the apparent hazard could be and
whether you can continue without first correcting the problem.
Checklist:
1. Check exterior covers for damage (loose, broken, or sharp edges).
2. Power off the computer. Disconnect the power cord.
3. Check the power cord for:
a. A third-wire ground connector in good condition. Use a meter to measure third-wire ground
continuity for 0.1 ohm or less between the external ground pin and the frame ground.
b. The power cord should be the authorized type specified for your computer. Go to: http://
www.lenovo.com/serviceparts-lookup
c. Insulation must not be frayed or worn.
4. Check for cracked or bulging batteries.
5. Remove the cover.
6. Check for any obvious non-Lenovo alterations. Use good judgment as to the safety of any non-Lenovo
alterations.
7. Check inside the unit for any obvious unsafe conditions, such as metal filings, contamination, water or
other liquids, or signs of fire or smoke damage.
8. Check for worn, frayed, or pinched cables.
9. Check that the power-supply cover fasteners (screws or rivets) have not been removed or tampered
with.
Notes:
1. Use product-specific ESD procedures when they exceed the requirements noted here.
2. Make sure that the ESD protective devices you use have been certified (ISO 9000) as fully effective.
Note: The use of a grounding system to guard against ESD damage is desirable but not necessary.
– Attach the ESD ground clip to any frame ground, ground braid, or green-wire ground.
– When working on a double-insulated or battery-operated system, use an ESD common ground or
reference point. You can use coax or connector-outside shells on these systems.
– Use the round ground prong of the ac plug on ac-operated computers.
DANGER
DANGER
DANGER
DANGER
DANGER
DANGER
DANGER
PERIGO
PERIGO
PERIGO
PERIGO
PERIGO
PERIGO
DANGER
DANGER
DANGER
DANGER
DANGER
DANGER
VORSICHT
VORSICHT
VORSICHT
VORSICHT
VORSICHT
VORSICHT
Before you go to the checkout instructions, ensure that you read the following important notes.
Important notes:
• Only certified trained personnel should service the computer.
• Before replacing any FRU, read the entire page on removing and replacing FRUs.
• When you replace FRUs, it is recommended to use new nylon-coated screws.
• Be extremely careful during such write operations as copying, saving, or formatting. Drives in the computer
that you are servicing sequence might have been altered. If you select an incorrect drive, data or programs might be
overwritten.
• Replace a FRU only with another FRU of the correct model. When you replace a FRU, make sure that the model
of the machine and the FRU part number are correct by referring to the FRU parts list.
• A FRU should not be replaced because of a single, unreproducible failure. Single failures can occur for a variety
of reasons that have nothing to do with a hardware defect, such as cosmic radiation, electrostatic discharge, or
software errors. Consider replacing a FRU only when a problem recurs. If you suspect that a FRU is defective, clear
the error log and run the test again. If the error does not recur, do not replace the FRU.
• Be careful not to replace a nondefective FRU.
What to do first
When you return a FRU, you must include the following information in the parts exchange form or parts return
form that you attach to it:
1. Name and phone number of service technician
2. Date of service
3. Date on which the machine failed
4. Date of purchase
5. Failure symptoms, error codes appearing on the display, and beep symptoms
6. Procedure index and page number in which the failing FRU was detected
7. Failing FRU name and part number
8. Machine type, model number, and serial number
9. Customer's name and address
Note: During the warranty period, the customer may be responsible for repair costs if the computer damage
was caused by misuse, accident, modification, unsuitable physical or operating environment, or improper
maintenance by the customer. Following is a list of some common items that are not covered under warranty
and some symptoms that might indicate that the system was subjected to stress beyond normal use.
Before checking problems with the computer, determine whether the damage is covered under the warranty
by referring to the following list:
If the power-on indicator does not turn on, check the power cord of the ac power adapter for correct
continuity and installation.
1 +20
2 0
3 Ground
Note: The output voltage across pin 2 might differ from the voltage that you measure.
3. Depending on the voltage that you measure, do one of the following:
• If the voltage is not correct, replace the ac power adapter.
• If the voltage is acceptable, do the following:
a. Replace the system board.
b. If the problem persists, call the Customer Support Center.
Note: Noise from the ac power adapter does not always indicate a defect.
2
3
2
4
6
8 7
9
8
10
12
13
14 11
15
17
16
18
19
20
21
3 Strip cover No No
5 K lock bracket No No
6 System board No No
7 I/O board No No
8 Speakers No No
9 heat sink and fan assembly No No
10 Memory module No No
12 Coin-cell battery No No
13 Wi-Fi card No No
14 Sponge No No
18 Storage drive No No
20 Battery pack No No
21 Lower case No No
Table 2. FRU categories for the LCD module – Lenovo Legion Y740–15
3 Hinges No No
2
3
2
4
8
7
9 8
10
13
14 11
16 15 12
17 18
19
21
20
22
3 Strip cover No No
5 K lock bracket No No
6 System board No No
7 I/O board No No
8 Speakers No No
9 Heat sink No No
10 Memory module No No
12 Subwoofer No No
13 Coin-cell battery No No
14 Wi-Fi card No No
15 Sponge No No
19 Storage drive No No
21 Battery pack No No
22 Lower case No No
Table 4. FRU categories for the LCD module – Lenovo Legion Y740–17
3 Hinges No No
Screw pack No No
Tape No No
Rubber No No
Thermalpad No No
General guidelines
When removing or replacing a FRU, ensure that you observe the following general guidelines:
1. Do not try to service any computer unless you have been trained and certified. An untrained person runs
the risk of damaging parts.
2. Begin by removing any FRUs that have to be removed before replacing the failing FRU. Any such FRUs
are listed at the beginning of each FRU replacement procedure. Remove them in the order in which they
are listed.
3. Follow the correct sequence in the steps for removing a FRU, as shown in the illustrations by the
numbers in square callouts.
4. When removing a FRU, move it in the direction as shown by the arrow in the illustration.
5. To install a new FRU in place, perform the removal procedure in reverse and follow any notes that
pertain to replacement.
6. When replacing a FRU, carefully retain and reuse all screws. If screws are missing, look up the Lenovo
parts numbers in “” on page for replacement screws and order them through the Lenovo CRM system.
7. When replacing the base cover, reapply all labels that come with the replacement base cover. If some
original labels are not included with the replacement base cover, peal them off from the original base
cover and paste them on the replacement base cover.
DANGER
Before removing any FRU or CRU, shut down the computer and unplug all power cords from
electrical outlets.
Attention: After replacing a FRU, do not turn on the computer until you have ensured that all screws,
springs, and other small parts are in place and none are loose inside the computer. Verify this by shaking the
computer gently and listening for rattling sounds. Metallic parts or metal flakes can cause electrical short
circuits.
Attention: The system board is sensitive to and can be damaged by ESD. Before touching it, establish
personal grounding by touching a ground point with one hand or by using an ESD strap (P/N 6405959).
a a
a
b
b
b a
a
b
Attention: Use your fingernail to pull the connector to unplug it. Do not pull the cable.
Figure 11. Take out the battery pack – Lenovo Legion Y740–15
Figure 12. Take out the battery pack – Lenovo Legion Y740–17
Step 2. Remove the solid-state drive by pulling it away from the slot.
Figure 15. Remove by pulling the M.2 solid-state drive – Lenovo Legion Y740–15
Note: For Lenovo Legion Y740–17, you have to remove the solid-state drive before removing the RTC
battery.
Attention: Use your fingernail to pull the connector to unplug it. Do not pull the cable.
Step 4. Remove 4 screws to release the metal frame and then remove the storage drive cable.
Figure 28. Remove the storage drive bracket – Lenovo Legion Y740–17
Step 2. Pull the retaining tags (on both sides of the slot) outwards to release the memory module. Remove
the memory module by pulling it away from the slot.
Step 4. Remove the Wi-Fi card by pulling it away from the slot.
Figure 47. Remove the heat sink and fan assembly– Lenovo Legion Y740–15
Step 1. Disconnect the cable between the I/O board and the system board.
Step 3. Disconnect the cables from the system board, including the touch pad cable and the display panel
cable.
Step 2. Remove 2 screws which secure the hinges to the upper case.
a
a b
b
aa
Figure 72. Pull the inner sides of the LCD bezel – Lenovo Legion Y740–15
Figure 73. Pull the inner sides of the LCD bezel – Lenovo Legion Y740–17
Step 1. For Lenovo Legion Y740–15, pull the two tapes (located on left and right edges under the LCD
panel) downwards steadily. With the bottom edge as an axis, lift up the top edge of the LCD panel.
Attention: Do not remove the LCD panel at this step. The LCD panel is connected by a cable at
the back side. Detach the cable before removing the LCD panel.
Step 2. Check the back side of the LCD panel for the LCD connector and then unplug the LCD cable.
Figure 86. Remove the camera and microphone board – Lenovo Legion Y740–15
Figure 87. Remove the camera and microphone board – Lenovo Legion Y740–17
b e h
c f i
d g
Figure 88. Label layout on the back side of the base cover– Lenovo Legion Y740–15
b e h
c f i
d g
Figure 89. Label layout on the back side of the base cover– Lenovo Legion Y740–17
Labels attached to the base cover are country/region specific. Make sure to apply the appropriate labels to
the replacement base cover.
I TW label Taiwan 70 mm x 10 mm
j Korea KCC label Korea 50 mm x 43 mm
Other company, product, or service names may be trademarks or service marks of others.