This document provides the technical specifications for a condenser unit that will be used in an ISP plant in Tuticorin, India. The condenser will have a single shell and will be used to condense 420 kg/hr of process fluid from 80°C to 40°C using cooling water that goes from 32°C to 37°C. Key details provided include the materials, dimensions, pressures, temperatures and heat transfer rates for the shell and tube sides. The condenser is required to perform desuperheating, condensation and subcooling of the process fluid.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
18 views1 page
ISPPart - IB 42
This document provides the technical specifications for a condenser unit that will be used in an ISP plant in Tuticorin, India. The condenser will have a single shell and will be used to condense 420 kg/hr of process fluid from 80°C to 40°C using cooling water that goes from 32°C to 37°C. Key details provided include the materials, dimensions, pressures, temperatures and heat transfer rates for the shell and tube sides. The condenser is required to perform desuperheating, condensation and subcooling of the process fluid.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1
Chapter-9 Technical specification
1 PROJECT: ISP, TUTICORIN
2 TAG NO.: 43 R5 3 Service of Unit: CODENSER (COOLING WATER) 4 Item No.: 5 Date: Rev No.: Job No.: 6 Size mm Type BEM Vert. Connected in 1 parallel 1 series 7 Surf/Unit(eff.) *** m2 Shells/unit Surf/shell (eff.) *** m2 8 PERFORMANCE OF ONE UNIT 9 Fluid allocation Shell Side Tube Side 10 Fluid name PROCESS FLUID COOLING WATER 11 Fluid quantity, Total kg/hr 420 *** 12 Vapour (In/Out) kg/hr 400 *** 13 Liquid kg/hr *** *** 14 Noncondensable kg/s 20 *** 15 16 Temperature (In/Out) °C 80 40 32 37 17 Dew / Bubble point °C *** *** 18 Density kg/m3 *** *** 19 Viscosity cP *** *** 20 Molecular wt, Vap *** *** 21 Molecular wt, NC 28 22 Specific heat kcal/(kg*°C) *** *** 23 Thermal conductivity kcal/(hr*m* °C ) *** *** 24 Latent heat kcal/kg *** 25 Inlet Pressure kgf/cm2a 2 4 26 Velocity m/s *** *** 27 Pressure drop, allow./calc. kgf/cm2 0.2 *** 0.5 *** 28 Fouling resist. (min) m *hr*°C/kcal 2 *** *** 29 Heat exchanged kcal/hr *** MTD corrected *** °C 30 Transfer rate kcal/( m2*hr*⁰C) Service *** Dirty *** Clean *** 31 CONSTRUCTION OF ONE SHELL Sketch 32 Shell Side Tube Side 33 Design/Test pressure kgf/cm2a 0-6 6 34 Design temperature °C 180 180 35 Number passes per shell *** *** 36 Corrosion allowance mm *** *** 37 Connections In mm *** *** 38 Size/rating Out mm *** *** 39 Intermediate *** *** 40 Tube No. *** OD *** mm Thks(avg) *** mm Length *** mm Pitch *** mm 41 Tube type PLAIN Material 316L STAINLESS STEEL Tube pattern *** 42 Shell ID *** mm OD mm MOC : SS 316L Shell cover *** 43 Channel or bonnet *** Channel cover *** 44 Tube sheet-stationary *** Tube sheet-floating *** 45 Floating head cover *** Impingement Plate *** 46 Baffle-cross Type *** Cut(%d) *** Spacing: c/c *** mm 47 Baffle-long *** Seal type *** Spacing: Inlet *** mm 48 Supports-tube *** U-bend *** Type *** 49 Bypass seal *** Tube-tube sheet joint *** 50 Expansion joint *** Type *** 51 RhoV2-Inlet nozzle *** Bundle entrance *** Bundle exit *** kg/(m*s2) 52 Gaskets - Shell side *** Tube Side *** 53 Floating head *** 54 Code requirements *** TEMA class R 55 Weight/Shell *** Filled with water *** Bundle *** kg 56 Remarks: EXCHANGER SHOULD BE DESIGNED FOR DE-SUPERHEATING, CONDENSATION AND SUBCOOLING. AS PER TEMA R 57 PROCESS FLUID COMPOSITION : TETRAHYDROFURAN VAPOR, INERTS (NITROGEN) 58 *VENDOR TO CONFIRM; *** VENDOR TO CALCULATE
Tender No.: HWB/ISP/2018/01 Process Tech. specs. Page P-40of 128