0% found this document useful (0 votes)
123 views2 pages

Isolation Amplifier

The document describes an isolation amplifier that provides galvanic separation between analog input and output signals. It has 8 programmable input and output ranges and can interface between different analog sensors and receiving instruments. Key features include excellent linearity, small size, and galvanic isolation over 4kV.

Uploaded by

Siva Raman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
123 views2 pages

Isolation Amplifier

The document describes an isolation amplifier that provides galvanic separation between analog input and output signals. It has 8 programmable input and output ranges and can interface between different analog sensors and receiving instruments. Key features include excellent linearity, small size, and galvanic isolation over 4kV.

Uploaded by

Siva Raman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

B1 B2 B3

ISOLATION
AMPLIFIER

INPUT

75,0 mm
OFFSET

GAIN
ISOLATION AMPLIFIER
Type: AISA
OUTPUT

+ - A1 A2

35,0 mm 100,0 mm

FEATURES Description:
The isolation amplifier is buildt with a linear optocoupler. It is
• Galvanic separation > 4kV designed for galvanic separation and conversion between dif-
ferent standards of analog input and output signals. Linearized
optic transmission is used to achieve high accuracy.
• 8 programmable input ranges
Application:
• 8 programmable output ranges To interface between different kinds of analog sensors and
receiving instruments, such as indicators, recorders, alarm
• Excellent linearity units and PLCs.

• Small outlines
PROGRAMMABLE FEATURES

INPUT ACTUATOR

0 - 20 mA
4 - 20 mA

0 - 1 V
0.2 - 1 V

0 - 5 V
1 - 5 V

0 - 10 V

CONNECTION DIAGRAM 2 - 10 V

Rail mounting

Supply
OUTPUT ACTUATOR
A1 A2
Input 0 - 20 mA

4 - 20 mA
+ VOLTAGE B3 0 - 1 V

+ CURRENT B2 0.2 - 1 V

COMMON B1 0 - 5 V

1 - 5 V
+ 0 - 10 V

2 - 10 V

OUTPUT CHARACTERISTICS
OUT OUT OUT OUT

IN IN IN IN

Input: 0 - 20 mA, 0 - 1 V, Input: 4 - 20 mA, 0.2 - 1 V, Input: 0 - 20 mA, 0 - 1 V, Input: 4 - 20 mA, 0.2 - 1 V,
0 - 5 V, 0 - 10 V 1 - 5 V, 2 - 10 V 0 - 5 V, 0 - 10 V 1 - 5 V, 2 - 10 V

Output: 0 - 20 mA, 0 - 1 V, Output: 0 - 20 mA, 0 - 1 V, Output: 4 - 20 mA, 0.2 - 1 V, Output: 4 - 20 mA, 0.2 - 1 V,
0 - 5 V, 0 - 10 V 0 - 5 V, 0 - 10 V 1 - 5 V, 2 - 10 V 1 - 5 V, 2 - 10 V
63

Thiim A/S Transformervej 31 Tel.: +45 4485 8000 Web: www.thiim.com


2730 Herlev - Denmark Fax: +45 4485 8005 Webshop: shop.thiim.com
SPECIFICATIONS ORDERING INFORMATION

INPUT EXAMPLE: AISA B230 D A 3 C


Programmable with Range
dipswitch TYPE
0 - 20 mA Max. input 100 mA Analog isolation amplifier AISA
4 - 20 mA Max. input 100 mA
0 - 1 V Max. input 50 V
0.2 - 1 V Max. input 50 V SUPPLY VOLTAGE
0 - 5 V Max. input 50 V 18-360 VDC and 20-264VAC E400
1 - 5 V Max. input 50 V 20-28 VAC B024
0 - 10 V Max. input 50 V 99-140 VAC B110
2 - 10 V Max. input 50 V 198-264 VAC B230
342-484 VAC B400
Adjustable type "A"
Offset potmeter. ± 100 % off full scale. ADJUSTMENT
Gain potmeter. 10 - 110 % off full scale. Input offset & gain adjustable A

Input resistance Input offset & gain fixed D


Voltage Approx. 28 kΩ
Current 10 Ω
HOUSING
Rail mounting (without transformer) A
PERFORMAMCE PARAMETERS
TIMING SIZE
Response time < 100 msec. 35 mm. 3
ELECTRICAL
Precision Class 0.5 according to DIN / EN60688 CODE END C
Linearity < 0,2 %
Ripple < 0.5 % pp
Temp. dependence ± 0.05 % / % °C
Supply dependence ± 0.01 % / % ∆U

OUTPUT
Programmable with Range Load
dipswitch
0 - 20 mA Max. Ω 500
4 - 20 mA Max. Ω 500
0 - 1 V Min. Ω 100
0.2 - 1 V Min. Ω 100
0 - 5 V Min. Ω 250
1 - 5 V Min. Ω 250
0 - 10 V Min. Ω 1000
2 - 10 V Min. Ω 1000

The output amplifier is protected against open and short circuit.

SUPPLY
AC and DC 18-360 VDC and 20-264 VAC
with isolated switchmode supply

AC supply range 24 V (From 20 to 28 V)


with transformer 110 V (From 99 to 140 V)
230 V (From 198 to 264 V)
400 V (From 342 to 484 V)

Frequency range 45 to 440 Hz (transformer)


Power consumption 2.5 VA, 1.1 W

GENERAL
Temperature range - 25 °C to + 55 °C
Humidity Up to 90 % RH non-condensing
Dielectric test voltage Between input and output 3000 VAC
Between input and supply 4000 VAC
Between supply and output 4000 VAC
Weight 0.12 kg

International Standards
EMC directive 89/336: EN50081 - Emission
EN50082 - Immunity
Low voltage directive 73/23: EN60255 - Electrical Relays
EN60688 - Measuring transducers