NE6188CZ

Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

NE6188CZ COMPRESSOR

TECHNICAL SPECIFICATION

HUANGSHI DONPER COMPRESSOR CO., LTD.

2021.01
NE6188CZ COMPRESSOR TECHNICAL SPECIFICATION

INDEX
page
1、Compressor Type………………………………………..2
2、Performance Data……………………………………….2
3、Running Condition………………………………………2
4、Compressor Mechanical Information……………………3
5、Compressor Shape……………………………………….3
6、Wiring Diagram…………………………………………4
7、Fixing of mounting bracket and cabinet base………….4
8、Starting relay and overload protector……………………5
9、Capacitor…………………………………………………6
10、Delivery State………………………………………….6
11、Package、Storage and Transportation…………………7
12、Technical Items…………………………………..……7

Page 1 of 8
NE6188CZ COMPRESSOR TECHNICAL SPECIFICATION

1. Compressor Type
Compressor model NE6188CZ
Rated voltage/frequency 220-240V~50Hz
Refrigerant R134a
Application Middle/High back pressure(M/HBP)
Cooling method Fan Cooling
Start torque High starting torque(HST)
Control device Capillary tube
Motor type CSIR
Starting capacitor 75μF

2. Performance Data
Cooling Capacity(≥95%) COP(≥95%)
Displacement

Oil Charge

W W/W
Net Wt.

CECOM
ASHRAE ASHRAE CECOMAF
AF
-15 -10 -5 0 5 7.2 10 5 7.2 5
cm3 kg ml w w w w w w w w w/w w/w
12.1 11.5±0.4 370±10 400 520 665 830 1010 1100 1230 952 2.20 1.89

Testing condition:
HBP
Test conditions
ASHRAE CECOMAF
Evaporating Temp. +7.2℃ +5℃
Ambient Temp. +35.0℃ +32℃
Condensing Temp. +54.4℃ +55℃
Suction Temp. +35.0℃ +32℃
Sub cooling Temp. +46.1℃ +55℃

3. Running Condition
Ambient temp. 0~43℃
Evaporating temp. -15~15℃
Voltage range 187~254V
Max. condensing temp. 65℃
Max. winding temp. 130℃
Max. shell temp. 110℃
Max. discharge temp. 130℃
Start voltage 187V [0.8/0.8MPa(abs)]

Page 2 of 8
NE6188CZ COMPRESSOR TECHNICAL SPECIFICATION

Shell min. resistance to pressure 35bar

4. Compressor Mechanical Information


Oil type POE
Viscosity 28.8~35.2 mm2/s(40℃)
Oil charged 370±10ml
Diameter of suction tube (I.D.) Φ8.15±0.1mm
Diameter of discharge tube(I.D.) Φ6.15±0.1mm
Diameter of process tube (I.D.) Φ6.15±0.1mm
Material of suction tube, process tube and
Copper tube
discharge tube
Compressor noise ≤55dB(A)
Vibration ≤1.2m/s2
Protecting gas Dry com. air(Dew point-60℃)

5. Compressor Shape

Caution:Suction tube and process tube can not be exchanged


Unmarked tolerance:±5mm

Page 3 of 8
NE6188CZ COMPRESSOR TECHNICAL SPECIFICATION

6. Wiring Diagram

Note: Each of the starting relay、the overload protector、the relaying cover 、the spring tap、
the spring for overload protector、the capacitor and the grounding screw is separately
provided by our company.

7. Fixing of mounting bracket and cabinet base

1、 Hexagon nut
2、 Spring washer
3、 Flat washer
4、 Compressor mounting bracket
5、 Rubber grommet
6、 Sleeve
7、 Cabinet base
8、 Screw

Note: Equipment assembly is all provided by our company. Above is just for reference,
details can refer to delivery state.
Page 4 of 8
NE6188CZ COMPRESSOR TECHNICAL SPECIFICATION

8. Starting relay and overload protector


8.1 Starting relay
Compressor model NE6188CZ
Type QL2-6.2
Max .Close Current A 6.80
Start
-ing Min Open Current S 5.85
relay
Changshu Tianyin Electromechanical Co. Ltd
Supplier
Hangzhou Star shuaier Electric Appliance Co.,Ltd.

8.2 Overload protector


Compressor model NE6188CZ
Type B100-105
Max.T.C Amp.(25℃) A 10.0
Prote- Trip time S 6~16
ctor Reset time S 30~105
Open temp. ±5℃ 105
Close temp. ±9℃ 55
Supplier: Changshu Tianyin Electromechanical Co. Ltd.
Hangzhou Star shuaier Electric Appliance Co.,Ltd.
First assembly force≤80N Sixth disassembly force≥12.5N
Flammability:Anti-flammability

Page 5 of 8
NE6188CZ COMPRESSOR TECHNICAL SPECIFICATION

9. Capacitor
Compressor model NE6188CZ
Model μF 75
Rated voltage V.AC 330
Starting Huangshan Zhenzhou Electronic Technology Co., Ltd.
Capacitor CD60
Supplier and model
FUXIN JIEKEDA ELECTRONIC CO.LTD
CD60

10. Delivery State


Quanti
No Name Model CODE
ty
1 Compressor NE6188CZ 1pcs
Φ10.3 1pcs
2 Rubber plug
Φ8.2 2pcs
3 Rubber grommet U model 4pcs QET-03U
Changshu Tianyin Electromechanical Co.,Ltd.
4 Starting relay QL2-6.2 1pcs
Hangzhou Star shuaier Electric Appliance Co.,Ltd.

Changshu Tianyin Electromechanical Co.,Ltd.


5 Overload protector B100-105 1pcs
Hangzhou Star shuaier Electric Appliance Co.,Ltd.
Huangshan Zhenzhou Electronic Technology Co., Ltd
6 Starting capacitor 75μF 1pcs
FUXIN JIEKEDA ELECTRONIC CO.LTD

7 Relaying cover E1 1pcs


8 Grounding screw QET.1-24C 1pcs
9 Sleeve QET-04 4pcs Φ11.1×17
10 Spring tap QET-09B 1pcs
Page 6 of 8
NE6188CZ COMPRESSOR TECHNICAL SPECIFICATION

Spring for
11 QET-07 1pcs
overload protector
Anchor bolt
12 QET-44 4pcs M6×30
assembly
13 Nut QET-27 4pcs
Notes:1.All electrical parts and equipment assembly are supplied separately, not installed on the
compressor.
2.All electrical parts and equipment assembly according to “Delivery state”are all
provided by our company.

11 Package、Storage and Transportation


Package type Unrecyclable
Quantity 60 pcs/box
Transportation By sea
Storage Max. 2 layers
Cross Weight Kg 725±24
Net Weight Kg 690±24
3
Volume m 0.96
Dimension: length×width×height (cm) 103×89×105
Wooden supporter 、 upper wooden
cover、foam divider、plastic sheet、
Main components
cardboard cover 、 rain-proof cover 、
wrapping
Keep the compressor in normal or
Movement
vertical position
No allowable compressor’s damage and
Trans. test requirement
performance loss.

12. Technical Items


⑴、Don’t take off the rubber plugs before using and installing compressor to prevent dust
and moisture.
⑵、Don’t turn down or incline the compressor during storage, transportation or installation
and avoid vibration and shock.
⑶、The compressor must be kept horizontally during running, the inclination angle must be
less than 5°.
⑷、The interval of compressor operation must be more than 4 minutes in order to obtain a
pressure balance in the systems.
⑸、Don’t start or run in the case of vacuum or charge high voltage in the compressor. The
compressor cannot be used to vacuumed the refrigeration system.
⑹、The design of refrigeration system must be suitable to insure the oil could flow back to
compressor.
⑺、The maximum ambient temperature of the compressor operation is 43℃.When
Page 7 of 8
NE6188CZ COMPRESSOR TECHNICAL SPECIFICATION

continuously operating under the maximum ambient temperature 43℃,the condensing


pressure and the peak pressure should not exceed as showing in the following table.
Refrigerant R134a
Max. condensing pressure 1.59MPa
Peak 2.0MPa
⑻、Widen the evaporating Temp. range of the compressor should be approved by
DONPER.
⑼、Compressor should be stored in a dry place.
⑽、Compressor accessories (eg: starting relay, overload protector etc.) are put in the
accessories box instead of fixing on the compressor.
⑾、The stocking period must be less than 6 months after the date of production. If longer,
you have to check whether the filled gas is sufficient. Replenishment must be done if
necessary.
⑿、It’s necessary to keep the compressor without rubber plug as short time as possible
(max time 10 min).
⒀、R134a systems require a filter with drying agent whith suitable for R134a refrigerant
⒁、The vacuum pump and the charging system must only be dedicated to R134a
⒂、The refrigeration system should minimize the content of chlorion and moisture, and
must be free of paraffin and silicon oil.
⒃、The organic substance non-compactable with R134a cannot be used in the refrigeration
system.

Page 8 of 8