Structure Analysis
Structure Analysis
PAGE NO. 1
****************************************************
* *
* STAAD.Pro CONNECT Edition *
* Version 22.09.00.115 *
* Proprietary Program of *
* Bentley Systems, Inc. *
* Date= SEP 2, 2023 *
* Time= 18:38:58 *
* *
* Licensed to: only@ ::LAVteam::® *
****************************************************
1. STAAD SPACE
INPUT FILE: C:\Users\wowmo\OneDrive\Desktop\LGU - Files\LGU - MEO Files-JGB-JGB\Bong Delizo\Design Ana.. .STD
2. START JOB INFORMATION
3. JOB NAME PROPOSED 2 STOREY COMMERCIAL BLDG.
4. JOB CLIENT MR. BL
5. JOB NO 001
6. ENGINEER NAME ENGR.JGB
7. ENGINEER DATE 9/9/2023
8. END JOB INFORMATION
9. INPUT WIDTH 79
10. UNIT METER KN
11. JOINT COORDINATES
12. 1 0 1.5 0; 2 4.8 1.5 0; 3 9.6 1.5 0; 4 14.4 1.5 0; 5 19.2 1.5 0; 6 24 1.5 0
13. 7 28.8 1.5 0; 8 0 1.5 7.3; 9 4.8 1.5 7.3; 10 9.6 1.5 7.3; 11 14.4 1.5 7.3
14. 12 19.2 1.5 7.3; 13 24 1.5 7.3; 14 28.8 1.5 7.3; 15 0 0 0; 16 4.8 0 0
15. 17 9.6 0 0; 18 14.4 0 0; 19 19.2 0 0; 20 24 0 0; 21 28.8 0 0; 22 0 0 7.3
16. 23 4.8 0 7.3; 24 9.6 0 7.3; 25 14.4 0 7.3; 26 19.2 0 7.3; 27 24 0 7.3
17. 28 28.8 0 7.3; 29 0 6 0; 30 4.8 6 0; 31 9.6 6 0; 32 14.4 6 0; 33 19.2 6 0
18. 34 24 6 0; 35 28.8 6 0; 36 0 6 7.3; 37 4.8 6 7.3; 38 9.6 6 7.3; 39 14.4 6 7.3
19. 40 19.2 6 7.3; 41 24 6 7.3; 42 28.8 6 7.3; 43 0 9 0; 44 4.8 9 0; 45 9.6 9 0
20. 46 14.4 9 0; 47 19.2 9 0; 48 24 9 0; 49 28.8 9 0; 50 0 9 7.3; 51 4.8 9 7.3
21. 52 9.6 9 7.3; 53 14.4 9 7.3; 54 19.2 9 7.3; 55 24 9 7.3; 56 28.8 9 7.3
22. 57 -1 6 0; 58 -1 6 7.3; 59 -1 9 0; 60 -1 9 7.3; 61 0 1.5 5.5; 62 4.8 1.5 5.5
23. 63 0 6 5.5; 64 4.8 6 5.5; 65 0 9 5.5; 66 4.8 9 5.5; 67 -1 6 3.65; 68 0 6 3.65
24. 69 4.8 6 3.65; 70 9.6 6 3.65; 71 14.4 6 3.65; 72 19.2 6 3.65; 73 24 6 3.65
25. 74 28.8 6 3.65; 75 -1 9 3.65; 76 0 9 3.65; 77 4.8 9 3.65; 78 9.6 9 3.65
26. 79 14.4 9 3.65; 80 19.2 9 3.65; 81 24 9 3.65; 82 28.8 9 3.65
27. MEMBER INCIDENCES
28. 1 1 2; 2 2 3; 3 3 4; 4 4 5; 5 5 6; 6 6 7; 7 8 9; 8 9 10; 9 10 11; 10 11 12
29. 11 12 13; 12 13 14; 13 1 61; 14 2 62; 15 3 10; 16 4 11; 17 5 12; 18 6 13
30. 19 7 14; 20 15 1; 21 22 8; 22 16 2; 23 23 9; 24 17 3; 25 24 10; 26 25 11
31. 27 18 4; 28 19 5; 29 26 12; 30 27 13; 31 20 6; 32 21 7; 33 28 14; 34 1 29
32. 35 2 30; 36 3 31; 37 4 32; 38 5 33; 39 6 34; 40 7 35; 41 8 36; 42 9 37
33. 43 10 38; 44 11 39; 45 12 40; 46 13 41; 47 14 42; 48 29 30; 49 30 31; 50 31 32
34. 51 32 33; 52 33 34; 53 34 35; 54 36 37; 55 37 38; 56 38 39; 57 39 40; 58 40 41
35. 59 41 42; 60 29 68; 61 30 69; 62 31 70; 63 32 71; 64 33 72; 65 34 73; 66 35 74
36. 67 29 43; 68 30 44; 69 31 45; 70 32 46; 71 33 47; 72 34 48; 73 35 49; 74 36 50
37. 75 37 51; 76 38 52; 77 39 53; 78 40 54; 79 41 55; 80 42 56; 81 43 44; 82 44 45
38. 83 45 46; 84 46 47; 85 47 48; 86 48 49; 87 50 51; 88 51 52; 89 52 53; 90 53 54
*** NOTE: MASS MODEL FORMED WILL BE USED IN SEISMIC/RESPONSE/TIME HISTORY LOADING, IF ANY.
IF MASS MODEL IS SEPARATELY PROVIDED IN INDIVIDUAL LOADING, THE GENERATED MASS
WILL BE REPLACED BY THE MASS PROVIDED IN INDIVIDUAL LOADING.
FLOOR DIAPHRAGM
************************************************************************************
NO. TYPE FL. LEVEL FL. WT CENTRE OF MASS CONTROL JOINT NO.
X Z
************************************************************************************
115. R1 1.0
116. LOAD 1 LOADTYPE SEISMIC-H TITLE EQX
117. REFERENCE LOAD
118. R1 1.0
119. PERFORM ANALYSIS
P R O B L E M S T A T I S T I C S
-----------------------------------
1 1.50 OK OK
2 6.00 OK OK
3 9.00 OK OK
120. CHANGE
121. LOAD 2 LOADTYPE SEISMIC-V TITLE EQZ
122. REFERENCE LOAD
123. R1 1.0
124. PERFORM ANALYSIS
125. CHANGE
126. LOAD 3 LOADTYPE DEAD TITLE DL
127. REFERENCE LOAD
128. R1 1.0
129. LOAD 4 LOADTYPE LIVE TITLE LL
130. ONEWAY LOAD
131. _2F_1WAY ONE -1.9 GY
**NOTE** about Floor/OneWay Loads/Weights.
Please note that depending on the shape of the floor you may
have to break up the FLOOR/ONEWAY LOAD into multiple commands.
For details please refer to Technical Reference Manual
Section 5.32.4.2 Note d and/or "5.32.4.3 Note f.
************************************************************
************************************************************
160. FINISH
************************************************************
* For technical assistance on STAAD.Pro, please visit *
* http://www.bentley.com/en/support/ *
* *
* Details about additional assistance from *
* Bentley and Partners can be found at program menu *
* Help->Technical Support *
* *
* Copyright (c) Bentley Systems, Inc. *
* http://www.bentley.com *
************************************************************