0% found this document useful (0 votes)
56 views5 pages

Manualde Parte Tennant ts5

This document provides instructions for replacing a defective drive module in Tennant floor cleaning machines. Key points: - The kit includes parts to replace the drive module and must be installed by an authorized Tennant service provider. - Installation requires accessing Tennant's Service Application Software to program the new drive module via USB. - Detailed steps are provided to remove the old module, install the new one, connect to the software, check for firmware updates, select options, program the module, and test the machine.

Uploaded by

saul
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
56 views5 pages

Manualde Parte Tennant ts5

This document provides instructions for replacing a defective drive module in Tennant floor cleaning machines. Key points: - The kit includes parts to replace the drive module and must be installed by an authorized Tennant service provider. - Installation requires accessing Tennant's Service Application Software to program the new drive module via USB. - Detailed steps are provided to remove the old module, install the new one, connect to the software, check for firmware updates, select options, program the module, and test the machine.

Uploaded by

saul
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

KIT NO.

9014613, 9015776, 9017641 Page 1 of 5

Drive Module Kit


Models: T300e, T300, T500e, T500, T600e, T600,
Speed Scrub 300, Speed Scrub 500

This kit includes the necessary parts to replace a defective Drive Module.
Kit installation is required by Tennant True Service or an authorized Tennant service provider.

NOTICE: This kit installation procedure requires access PROGRAM THE DRIVE MODULE:
to the Tennant Service Application Software to program
See TENNANT SERVICE APPLICATION SOFTWARE
the new Drive Module. To access or download the
on page 3 to access or download software.
software refer to page 3.
1. Reconnect the battery cables to machine.
Authorized Tennant service providers:
If the Tennant Service Application Software is currently 2. Start the Service Software Application program
installed on your computer, ensure latest software version “Service Diagnostics...”(Figure 1). Refer to
is installed for new firmware updates. Figure 9 for further details.

INSTALLATION INSTRUCTIONS:
Installation Time: 1 Hour Icon on
Kit Installation Requirements: Tennant ServiceLink Desktop
computer or a computer with Wi-Fi connection to access
the Tennant Service Application Software, and USB cable
(supplied with kit).
Computer System Requirements: Windows  7 OS, Fig. 1
Microsoft .NET Framework 4.5 or later, USB Port. 3. After software start up, the following screen will
appear (Figure 2).
Special Tool Required: T- 25 torque screwdriver
Kit Contents

Ref Part No. Description Qty.


1 9014613 Drive Module Kit [T300e/T300/SS300] 1
1 9015776 Drive Module Kit [T500e/T500/SS500] 1
1 9017641 Drive Module Kit [T600e/T600] 1 Fig. 2
2 1071235 USB Cable (included with kit) 1 4. Connect the USB cable, supplied with kit, to computer
and to the USB port on machine as shown. Turn the
key switch to the on position (Figure 3).
INSTALL THE NEW DRIVE MODULE:
FOR SAFETY: Before servicing machine, stop on
level surface, turn off machine, and set parking brake
if equipped.
1. Disconnect battery cables from machine.
WARNING: Always disconnect battery cables
from machine before working on electrical
components.
2. Replace the defective drive module with new drive
module. Some machine dis- assembly is required to
access the drive module. If necessary, refer to the
Service Manual for drive module removal instructions.
3. Program the new drive module as described in the Fig. 3
following instructions.

9014614 Rev. 04 (09- 2020) Tennant Company www.tennantco.com


KIT NO. 9014613, 9015776, 9017641 Page 2 of 5

5. The application software will then connect to the 8. T600/e models: If transaxle is equipped with the
machine (Figure 4). If the application remains on the electronic park lock option, select “Parking Brake”.
“Connecting to Machine...” screen for an extended If not equipped, select “Default” (Figure 7).
period, cycle key or reconnect USB cord. If it still fails to For all other models: Select “Default”.
connect, restart software or computer.
Then press “Program” button to program iDrive
(Figure 7).

Fig. 4
6. Once connected, the home screen will appear (Figure
5). Before programming the new drive module, first
check if any firmware updates are required. The
“Firmware” button will be highlighted in yellow if
updates are required. Press button to update firmware
(Figure 5). Fig. 7
9. Programming may take several seconds to complete
(Figure 8). Follow instructions on screen if prompted
to cycle key to complete process.
NOTE: If the “Writing iDrive Configuration” process
gets stuck for an extended period, make sure that:
S iDrive has power applied
S E- Stop button is released / not pressed in
S For model T300 only, does not apply to “e” model or
Continue with the firmware update by pressing the Speed Scrub 300 model:
yellow “Update” button as shown B+ is present at main control board pins J9- 2
(E- Stop input) and J9- 7 (iDrive B+ Detent)
S For models T500 & T600 only, does not apply to “e”
models or Speed Scrub 500 model:
B+ is present at main control board pins J12- 2
(E- Stop input) and J12- 7 (iDrive B+ Detent)

Fig. 5

7. Click the “iDrive” button to enter the programming


screen (Figure 6).

Fig. 8

10. Disconnect the USB cable.


11. Test machine to ensure the drive module is
functioning properly. If a fault code appears check the
wire harness connections at drive module and recycle
key.

Fig. 6

9014614 Rev. 04 (09- 2020) Tennant Company www.tennantco.com


KIT NO. 9014613, 9015776, 9017641 Page 3 of 5

TENNANT SERVICE APPLICATION Authorized Tennant Service Providers:


SOFTWARE: The Service Application Software can be downloaded
The Tennant Service Application Software is required to from the Tennant Public website as described below.
program the new drive module. The software can be
accessed or downloaded as described below. NOTE: If the Service Application Software is currently
installed on your computer, confirm or re-install the
software to ensure latest software version is installed.
Tennant True Service with ServiceLink
computers: To access the Service Application Software, go to
www.tennantco.com. Depending on your geographical
The software is pre-installed on your computer as shown location, the website may have a “My Account Log
below. The software application is titled “Service In/Sign Up” button at the upper right or a “My Tennant
Diagnostics” (Figure 9). Customer Sign In” tab at the upper right of the Tennant
website as shown below (Figure 10).
Icon on
Desktop Proceed with the software download instructions as
described on the following pages.

Website with “My Account Log In/Sign Up” button


(Access to “My Account”)

From Start menu

OR
Website with “My Tennant Customer Sign In” tab
(Access to My Tennant)

From Start menu > All Programs > Tennant Company >
Tennant Service Diagnostics

Fig. 10

Fig. 9

9014614 Rev. 04 (09- 2020) Tennant Company www.tennantco.com


KIT NO. 9014613, 9015776, 9017641 Page 4 of 5

Website with “My Account Log In/Sign Up” 4. Within the Service Application Software page, click on
the link titled “Service Diagnostics LE version
button: x.x.xx” (Figure 14).
1. Press “My Account Log In/Sign Up” to open or create
an account (Figure 11).

Fig. 14
5. To download the service software continue to click as
instructed then click the Save button (Figure 15).
Fig. 11
2. Once logged in to the “My Account” website, click on
the “DISTRIBUTOR RESOURCES” link as shown
below (Figure 12).
NOTE: For internal customers, the link will be titled
“INTERNAL RESOURCES”.

Fig. 15
6. Open the “Downloads” folder and locate the
Fig. 12 “LE_Setup_xxxx” zip file. Open the zip file and double
3. Click on the “SERVICE APPLICATION SOFTWARE” click on the “LE_Setup_xxx” file to install the
link as shown below (Figure 13). application software on your computer (Figure 16).
Follow instructions on screen to install.

Fig. 16
7. After the service application software is installed on
your computer, refer to figure 9 to access the
Fig. 13 program.

9014614 Rev. 04 (09- 2020) Tennant Company www.tennantco.com


KIT NO. 9014613, 9015776, 9017641 Page 5 of 5

Website with “My Tennant Customer Sign in” 3. Within the Service Application Software page, click on
tab: the link titled “Service Diagnostics LE version
x.x.xx” to download the application installer then click
1. Log in to the “My Tennant” website or register as a the Save button (Figure 19).
new user (Figure 17).

Fig. 17
2. Once logged on to the “My Tennant” website, click on
the “Service Application Software” link under the
“Product Support & Solution” section as shown below
(Figure 18).

Fig. 18

Fig. 19
4. Open the “Downloads” folder and locate the
“LE_Setup_xxxx” zip file. Open the zip file and double
click on the “LE_Setup_xxx” file to install the
application software on your computer (Figure 20).
Follow instructions on screen to install.

Fig. 20
5. After the software is installed on your computer, refer
to figure 9 to access the program.
9014614 Rev. 04 (09- 2020) Tennant Company www.tennantco.com