Datasheet HM9B
Datasheet HM9B
Datasheet HM9B
Specification:
Accuracy class OIML R60 C3
Output sensitivity ( = FS ) mV/V 2.0 ± 0.002
Maximum capacity ( Emax ) t 10, 20, 25 30, 40 SE, 40, 50
Maximum number of load cell intervals ( nLC ) nlc 3000
Ratio of minimum LC verification interval Y = Emax / vmin Y 15000 7500
Combined Error %FS ≤ ± 0.023
Minimum dead load t 0
Safe overload of Emax 150 %
Ultimate overload of Emax 300 %
Zero balance of FS ≤ ± 1.5 %
Excitation, recommended voltage V 5 ~ 12
Excitation maximum V 18
Input resistance Ω 700 ± 7
Output resistance Ω 700 ± 7
Insulation resistance MΩ ≥ 5000 ( at 50VDC )
Temperature range, compensated °C -10 ~+40
Temperature range, operating °C -35 ~ +65
Element material Alloy steel
Ingress Protection (according to EN 60529) IP68
ATEX classification (optional) II1G Ex ia II1C T4 II1D Ex iaD 20 T73°C II3G nL IIC T4
Please visit our website WWW.ZEMIC.NL for the most actual information Nr. 2010.12 HM9B Rev3