Relevant instructions for external power supply

and wiring of 2-wire video intercom products


(2020-1-20)
Involved model:

Indoor Station DS-KH6320-WTE2


Modular Door Station DS-KD8003-IME2
Device Model
DS-KAD706
Distributor
DS-KAD704

Power description:
(1) 2-Wire Distributor
CH6 CH1-5
KAD706 16W 6W
CH4 CH1-3
KAD704 8W 6W

(2) Modular Door Station:


The main module & the sub-module maximum power consumption:
Stable power consumption
DS-KD8003-IME2 4W
DS-KD-KK 0.8W
DS-KD-KP 1W
DS-KD-DIS 2.5W
DS-KD-E 0.8W
DS-KD-M 0.8W
DS-KD-INFO 1.5W

(3) Indoor Station


Stable power consumption
DS-KH6320-WTE2 6W

Example of the calculation model of the modular door station sub-module


The sum of the power consumption of each module must be less than the total power
consumption of the power supply.
2-wire
Model DS-KD8003-IME2 DS-KD-DIS DS-KD-KP / /
Quantity 1 1 1 / /
Power 4W 2.5W 1W Total:7.5W
Because 7.5W < 8W, we can support powering this device through KAD706 channel 6 or
KAD704 channel 4.

2-wire
Model DS-KD8003-IME2 DS-KD-M DS-KD-KK /
Quantity 1 1 12 /
Power 4W 0.8W 9.6W Total:14.4W
Because 8W < 14.4W < 16W, we can support powering this device through KAD706
channel 6.

Wire testing standards:


(1) When there are multiple cores in one parallel line, only one pair of closed cores are
allowed to transmit signal. It is not allowed to use multiple pair of cores in one cable to
transmit signal;
(2) When using parallel lines, it is suggested to use those with shielding layer. If dual
core or multiple core parallel lines without shielding layer are routed, stability of signal
transmission can be effected. You need to run a test before installation;
(3) Impedance of twist pair in network cable are over 42Ω/100m, so network cable
cannot transmit enough power to indoor station. Network cable is not allowed to use
during installation;
(4) Strong electricity and weak electricity cannot be wired in the same route, they need
to be wired separately and the distance should be more than 0.5 meter;

Table A

Twisted Pair : Twisted Pair : Twisted Pair : Twisted Pair : Parallel lines
Routing Path
24AWG (0.2𝑚𝑚2) 20AWG (0.5𝑚𝑚2) 18AWG (0.8𝑚𝑚2) 16AWG (1𝑚𝑚2) (0.5𝑚𝑚2~0.8𝑚𝑚2 )

DS-KAD706-S-DS- Transmission Transmission Transmission Transmission Transmission

KAD706 Distance≤60m Distance≤60m Distance≤60m Distance≤50m Distance≤35m

DS-KAD706-DS- Transmission Transmission Transmission Transmission Transmission

KAD706 Distance≤60m Distance≤60m Distance≤60m Distance≤50m Distance≤35m

DS-KAD706-DS- Transmission Transmission Transmission Transmission Transmission

KD8003-IME2 Distance≤35m distance≤60m distance≤60m distance≤50m distance≤35m

DS-KAD706-DS- Transmission Transmission Transmission Transmission More parameters in

KH6320-WTE2 Distance≤35m Distance≤100m Distance≤100m Distance≤100m Table B

Table B

Routing Path Parallel lines: Parallel lines: Parallel lines: Parallel lines:
24AWG (0.2𝑚𝑚2 ) 20AWG (0.5𝑚𝑚2 ) 18AWG (0.8𝑚𝑚2 ) 16AWG (1𝑚𝑚2 )

DS-KAD706- Transmission Transmission Transmission Transmission

DS- KH6320-WTE2 Distance≤50m Distance≤100m Distance≤100m Distance≤100m

Device Installation
(1) Installation environment (temperature, moisture etc.) need to follow requirements in
specification or power output can be effected
(2) Power consumption of modular door station (main module and sub modules) should be
less than 12W. Please reach local technical support if you are not sure about power
consumption of each module. Door station should be connected to CH6 of the video/audio
distributor. If modular door station is connected to any terminal of CH1 to CH5, up to 3 sub
modules can be connected;
(3) Indoor station should be connected to any terminal of CH1 to CH5 of the video/audio
distributor;
(4) Up to 15 video/audio distributor can be cascaded. If more distributors are needed, you
should cascade network switch supporting 1000Mbps. The whole 2-wire system can have up
to 500 devices.
(5) Power supply must be certified by Hikvision;