Welcome to OMICRON! We are happy that you have chosen a COMPANO 100 test set.
COMPANO 100 is a lightweight, highly flexible fully electronic current or voltage source for various
checks in an electrical energy system, such as generation, transmission, distribution, railways or
industry. It is battery-operated; you do not need any additional power source for the test set. The
battery is rechargeable. We are certain that you will enjoy using this product. The following guide will
provide you with information related to the package and services that will enable you to use this
product with confidence.
License
The license for working with COMPANO 100 is already integrated into your test set. You do not need
an additional activation key to use COMPANO 100.
Get started
For information on how to get started with the COMPANO 100 test set, refer to the chapters "Safety
instructions", "Battery", "Test set overview" and "Product startup". These chapters are identical in
Getting Started manual and User Manual.
Stay informed
Our Customer Portal is an international knowledge exchange platform full of useful information. Here
you can inform yourself about the latest product and application features and software updates. You
can also find up-to-date articles, conference papers, user manuals and much more.
Furthermore, you can share your own experiences in the OMICRON User Forum.
Register today: www.omicronenergy.com/customer.
Learn more
You can learn more about your new product in one of the customized training courses offered by the
OMICRON Academy.
For more details have a look at: www.omicronenergy.com/academy.
Get support
Well-educated and competent technicians are available to answer all of your questions on our
technical support hotline. All around the clock.
Make use of our 24/7 international technical support hotline: → Support on page 24.
OMICRON 3
Getting Started with COMPANO 100
Scope of documentation
The printed Getting Started manual guides you through the first steps and actions with the
COMPANO 100 test set.
The COMPANO 100 User Manual, available as PDF and invocable in chapters
by scanning the according QR code in the test set's lid with your smart phone,
was written for professional specialists in electronics and electrical engineering.
Its purpose is to familiarize you with the COMPANO 100 test set and its various
application fields. It contains helpful instructions on how to use COMPANO 100
safely, properly, and efficiently. Read the User Manual manual thoroughly.
At Google Play and in the Apple App Store (iOS) you find an app called "COMPANO Knowledge
Access Point" with a QR code reader for offline access to the manuals.
4 OMICRON
About this manual
DANGER
Death or severe injury will occur if the appropriate safety instructions are not
observed.
WARNING
Death or severe injury can occur if the appropriate safety instructions are not
observed.
CAUTION
Minor or moderate injury may occur if the appropriate safety instructions are not
observed.
NOTICE
Equipment damage or loss of data possible
OMICRON 5
Getting Started with COMPANO 100
3 Safety instructions
WARNING
Death or severe injury can occur if the appropriate safety instructions are not
observed.
► The COMPANO 100 test set can output life-hazardous voltages and currents.
► Before operating any such electrical equipment, carefully read the Safety
Instructions section of this manual.
► Do not use (or even turn on) any electrical equipment without understanding the
information in its manual.
► Existing national safety standards for accident prevention and environmental
protection may supplement the equipment's manual.
► Only trained personnel should work with COMPANO 100.
For your own safety always follow the 5 basic safety rules:
1. Disconnect completely.
2. Secure against re-connection.
3. Verify that the installation is dead.
4. Carry out grounding and short-circuiting.
5. Provide protection against adjacent live parts.
6 OMICRON
Safety instructions
OMICRON 7
Getting Started with COMPANO 100
• If the COMPANO 100 test set does not seem to function properly, contact OMICRON's Technical
Support (→ Support).
3.3 Cleaning
To clean the COMPANO 100 test set, use a cloth dampened with isopropanol alcohol. Prior to
cleaning, always switch off the On/Off power switch and unplug the battery charger.
8 OMICRON
Safety instructions
OMICRON 9
Getting Started with COMPANO 100
WARNING
Death or severe injury caused by high voltage possible
The outputs of the COMPANO 100 are controlled by the software running in the device.
Note that just turning off the outputs in the controlling software is not sufficiently safe.
► Do not work on connected touchable test objects, connections or teminals while
the COMPANO 100 is active (Start/stop pressed) .
► Always make sure that the Emergency stop button is pressed, the test set is
secured against reactivation, and all parts in the working area are powerless
before you work on touchable test objects, connections or terminals (see Wiring
and Safe Connection on page 9).
The COMPANO 100 test set is supplied with flexible test lead adapters Retractable sleeve
(2 x black, 2 x red) that have an angled connector at one end, and a
retractable sleeve at the other end.
Never directly insert one of the retractable sleeves into a
COMPANO 100 socket at the front of the test set. This does not
comply with the designated purpose of these leads and is contrary
to the safety regulations.
Angled connector
To connect a test object to COMPANO 100, At the test object, use the test lead's
always use the angled connectors for the retractable sleeve side:
test set's sockets:
10 OMICRON
Safety instructions
Terminal adapters
Use flexible or hard terminal adapters to connect regular test leads to screw-clamp terminals.
Flexible terminal
adapter
Hard
terminal Flexible terminal
adapter Regular test lead adapter
COMPANO 100
WARNING
Death or severe injury caused by high voltage possible
The terminal adapters have blank ends.
► Before connecting the terminal adapters, press the Emergency stop button on the
COMPANO's front panel and secure the test set against reactivation (see Wiring
and Safe Connection on page 9).
► Always insert the terminal adapter with its blank end first into the terminal strip, and
fasten it before connecting it to a test lead.
OMICRON 11
Getting Started with COMPANO 100
• The warning symbol on the COMPANO 100 front panel indicates that the device is activated,
and that its outputs may carry dangerous voltages.
Even if the test set does not indicate dangerous output voltage, it's safe to always consider the
outputs live. The indicator could be defective. Also a software error or remote command could
accidentally start the test set. You may assume the outputs to be free of dangerous voltage when
the emergency stop button is pressed (see Wiring and Safe Connection on page 9).
12 OMICRON
Safety instructions
WARNING
Death or severe injury caused by high voltage or current possible.
Employ the proper test set.
► Never use COMPANO 100 to directly inject currents into power cables or overhead
lines. If this should become inevitable, use the CPC 100 test set together with
CP CU1 and CP GB1.
The auxiliary current probe can carry life-threatening voltages during the test. In case of
an error, unexpected high voltages can occur at output I OUT or V OUT at any time.
Also the step voltage around the auxiliary current probe can be quite high.
► Always press the emergency stop button before working with these connectors.
► Use the provided warning flag*) to mark the auxiliary current probe.
► Mark an area of 5 m/15 ft around the electrode as dangerous zone, and position a
guard outside this area to keep people from entering the dangerous zone.
In case of a high-current ground fault within the substation or at the transmission tower
during the test, high voltages may occur in any wire connected to the grounding grid or
leading away from it.
► Do not touch the current probe, the potential probe or any wire without insulating
gloves.
► First insert the current probe, then connect it to the provided crocodile clamp.
Before removing the current probe, disconnect the crocodile clamp.
*)
Warning flag for auxiliary current probes provided by OMICRON.
OMICRON 13
Getting Started with COMPANO 100
3.4.7 Accessories
Only use COMPANO 100 in combination with original OMICRON accessories as explained in the user
manual. Only use COMPANO 100 accessories with other OMICRON devices when this usage is
described in the respective device's user manual.
However, if there are any signs of a defective lithium-ion battery, transportation is not allowed.
For customers outside the European Economic Area
Contact the authorities in charge for the relevant environmental regulations in your country, and
dispose of the OMICRON test set in accordance with your legal local requirements.
see Handling defective lithium-ion batteries on page 17.
14 OMICRON
Battery
4 Battery
The internal battery of the COMPANO 100 test set is a 152 Wh rechargeable lithium-ion battery. When
working with rechargeable lithium-ion batteries, certain safety issues apply:
• There is a risk of fire and burns when handled inappropriately. Do not drop or crush the battery,
and refrain from opening it. Do not short out the battery contacts, and never expose the battery to
high temperatures. Dispose of properly. The battery may explode if damaged or disposed of in fire.
• Do not immerse in any liquid. Avoid the battery to come in contact with chemicals.
• Before charging the battery, read the relevant chapters of the manual. Use the OMICRON-
supplied charger, only. Do not charge the battery in a flammable environment. Charge/discharge
the battery in the permitted temperature range, only (see User Manual chapter Technical Data ►
Battery). To avoid damaging the battery, charging is terminated automatically when the
temperature exceeds that range. You can check the battery status and temperature at Setup ►
Battery Info.
• In order to ensure a long lifetime, a battery should not be charged at extreme temperatures.
Therefore, COMPANO 100 controls the permissible temperature range for the battery to be
charged. If the battery inside the test set is either too hot or too cold, COMPANO 100 automatically
prevents charging.
For more information about the charging temperature of the battery see chapter Technical data ►
Battery in the User Manual.
• If the battery is fully charged, the charger stops charging. If kept connected, the charger restarts
charging automatically if the battery is down to approximately 90 %. If the charger is reconnected
to the power supply, charging will start immediately (as long as the battery temperature is within
the specified range).
• If you do not use the COMPANO 100 test set for a longer period of time, recharge the battery once
every 6 months.
Dangerous Good Class 9 label combined Dangerous Good Class 9 label combined
with the UN 3480 number. with the UN 3481 number.
OMICRON 15
Getting Started with COMPANO 100
16 OMICRON
Battery
OMICRON 17
Getting Started with COMPANO 100
18 OMICRON
Test set overview
On/Off
Application Start/stop
modules
Save
WARNING
Death or severe injury caused by high voltage possible
Inductive loads may contain a lethal amount of energy if charged with current. The
amount of energy depends on the size of the inductive load, the strength of the applied
current, and the frequency. To give an example, 350 mJ are assumed as safe
according to the safety standard IEC 61010-1. Particularly critical devices are potential
transformers or current transformers, but also the inductive part of other test objects
can be critical.
► If you connect loads >0.3 mH to the COMPANO 100 current output I OUT, do not
touch the outputs or anything that is connected to them.
The binary and/or analog inputs IN 1 and IN 2 may conduct hazardous voltages. The
insulation against other potential hazardous voltages is implemented as functional
insulation, and they are not isolated against each other (common N).
► Never connect touchable test objects to the inputs without having secured the
dangerous area.
OMICRON 19
Getting Started with COMPANO 100
Side view:
Note: You can remove the dongle shown in the picture above (the connector for external safety
functions) to protect COMPANO 100 from unauthorized usage.
WARNING
Death or severe injury can occur if the appropriate safety instructions are not
observed.
The OMICRON-supplied charger has a magnetically attached power connector.
Magnets can impact the function of pace makers and implantable cardioverter-
defibrillators (for example, actuation of reed switch).
► Keep a minimum distance of 20 cm/8 inch between the magnetic connector and
the implanted devices to prevent malfunction and danger to health.
20 OMICRON
Product startup
6 Product startup
First, charge the battery
When shipped, the battery inside the COMPANO 100 test set is partly charged, and the test set can be
used immediately. To fully charge the battery, grant a charging time of about 90 minutes.
Use the OMICRON-supplied charger, only. That charger has a magnetically attached power connector.
Such a connector has the advantage that, when it is tugged — for example, by someone tripping over
the cord — it will pull out of the test set's socket without damaging the connector or the socket.
Then connect COMPANO 100 to the device you would like to test
For safety reasons, press the emergency stop button while connecting, and secure the test set
against reactivation (see Wiring and Safe Connection on page 9).
The illustration below shows current output I OUT connected to an overcurrent protection relay. The
relay's potential-free trip contact is connected to binary input IN 1.
Trip contact 51
Time
Inst
Trip contact 50
Overcurrent
protection relay
OMICRON 21
Getting Started with COMPANO 100
A battery running low also initiates a system shutdown, shortly before a looming power supply loss.
Check out the COMPANO 100 Product Startup video on the OMICRON Video
Channel (visit https://www.omicronenergy.com/COMPANO100-Startup).
1. Turn the jog dial wheel until the focus is on the output current field.
2. Press the jog dial wheel, set the current to a value of your choice (that is, a value that will make
the relay trip for sure), then press the jog dial wheel again.
3. By default, the timer is configured to start when you press the Start/Stop key, and to end when
there is a change at the dry contact connected to IN 1. Therefore, for many applications it may not
be necessary to change the timer from its default.
4. Press the Start/Stop key. The current is issued at the current output.
5. The current output is turned off by default as soon as the binary contact of the relay switches.
6. The timer records the duration of the relay trip time, that is, the time it took the relay to trip starting
from the moment of the current injection.
22 OMICRON
Technical Data
7 Technical Data
The technical data listed below are an extract of the Technical Data chapter of the COMPANO 100
User Manual.
Environmental conditions
• Operating temperature: -10 °C ... +50 °C (14 °F ... 122 °F).
• Maximum altitude for operation: 4000 m (13.123 feet).
• Maximum altitude for storage: 15000 m (49.212 feet).
• Humidity: 5 % ... 95 % relative humidity, no condensation.
• Protection class: IP20 according IEC 60529.
Size, weight
• Weight: 9.9 kg (22 lb); case without protection cover.
• Dimensions (w × h × d): 360 × 312 × 210 mm (14.2 × 12.3 × 8.3 in).
Battery charger
• Connection: C14 connector according to IEC 60320-1.
• Nominal voltage: 115 V AC/230 V AC.
• Nominal frequency: 50/60 Hz.
• Maximum input current: 2.1 A.
• Maximum output power: 100 W.
Analog Inputs
• Measurement Category: CAT III/300 V.
Analog Outputs
• Current output I OUT: 1 x 110 A AC or 100 A DC.
• Voltage output V OUT: 1 x 150 V AC or 220 V DC.
OMICRON 23
Getting Started with COMPANO 100
8 Support
When you are working with our products we want to provide you with the greatest possible benefits. If
you need any support, we are here to assist you!
www.omicronenergy.com/support
At our technical support hotline, you can reach well-educated technicians for all of your questions.
Around the clock – competent and free of charge.
Make use of our 24/7 international technical support hotline.
Additionally, you can find the OMICRON Service Center or OMICRON Sales Partner closest to you at
www.omicronenergy.com/addresses
www.omicronenergy.com/customer
The Customer Portal on our website is an international knowledge exchange platform. Download the
latest software updates for all products and share your own experiences in our user forum.
Browse through the Knowledge Library and find application notes, conference papers, articles about
daily working experiences, user manuals and much more.
www.omicronenergy.com/academy
Learn more about your product in one of the training courses offered by the OMICRON Academy.
OMICRON electronics GmbH, Oberes Ried 1, 6833 Klaus, Austria. +43 59495.
24 OMICRON
ENU 1122 03 04