0% found this document useful (0 votes)
114 views23 pages

Professional Sound Level Meter

The document describes Tenlee Group's noise and vibration testing instruments, including conventional sound level meters, noise integral statistics analyzers, precise impulse sound level meters, and environment vibration analyzers. The company specializes in developing these types of instruments and has authorization for sound level meter calibration. The instruments are used for applications such as scientific research, environment protection, and industrial testing.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
114 views23 pages

Professional Sound Level Meter

The document describes Tenlee Group's noise and vibration testing instruments, including conventional sound level meters, noise integral statistics analyzers, precise impulse sound level meters, and environment vibration analyzers. The company specializes in developing these types of instruments and has authorization for sound level meter calibration. The instruments are used for applications such as scientific research, environment protection, and industrial testing.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 23

SOUND AND VIBRATION TEST INSTRUMENT

Contents
1. Company introduction…………………………………………....2
2. Conventional sound level meter………………………………….3
3. Noise integral statistics ( frequency spectrum )analyzer…….....6
4. Precise impulse sound level meter……………………………….9
5. Individual sound exposure meter………………………………..11
6. Noise automatic measurement and analysis system…………….12
7. Noise integral average sound level meter……………………….14
8. Precise noise frequency spectrum analyzer……………………..16
9. Environment vibration analyzer…………………………………18
10. Mechanical vibration tester…………..……………………….….19
11. Sound level meter calibrator and microphone………………….21
12. Octave………………………………………………………….......22

Tenlee Group Piezotronics Inc 1


Email: [email protected] WEB: http://www.t-measurement.com
1. company introduction
Based on several tens of years experience and innovation, we are specialized in

researching and developing noise, vibration and electroacoustics measuring instruments.

We have authorized sound level meter measurement calibration station and we are the

main researching, developing and manufacturing base in China.

We have deep technology and advanced equipments for scientific development,

manufacturing and quality inspection. We are the first manufacturer to develop and

manufacture noise, vibration measurement instruments. With complete quality system,

we have passed ISO 900:2000.

Our products are of good quality and competitive price. They are widely applied in

scientific research, education, environment protection, health, transportation, aerospace,

industrial mining, etc..

2. conventional sound level meter


Tenlee Group Piezotronics Inc 2
Email: [email protected] WEB: http://www.t-measurement.com
TL5633 sound level meter

It meets IEC 61672 standard, GB/T3785 standard and the second class sound level meter standard of JJG188-2002
sound meter verification regulations.
It is suitable for various routine tests.
Basic configuration: host machine, microphone (TL14423), fan cover, horologe screwdriver, handbag

Characteristics:
digital display, high and low measuring range, overload and under-range indication
max instant sound level hold

Specification
modal TL5633
Measuring range 35dB-130dB (A)
Frequency weighting A
Frequency range 20HZ-8kHZ
Measuring rang level 1) L(low): 35dB-100dB, >100dB overload indication
2)H(high):70Db-130dB, < 70dB under-range
indication, >130dB overload indication
Digital indication 3.5 digits LCD, resolution ratio 0.1dB, updating speed
1 time/sec
Sound calibration TL 6020 ( 94dB,1000HZ)
Power DC 7v-9v
Service environment Temperature: -10℃-50℃
Humidity: 25%-90%
Atmosphere: 65kPa-108kPa
Dimensions 162mm×62mm×24mm
Weight 0.18kg ( with battery)

Tenlee Group Piezotronics Inc 3


Email: [email protected] WEB: http://www.t-measurement.com
TL5633B sound level meter
It meets IEC 61672 standard, GB/T3785 standard and the second class sound level meter standard of JJG188-2002
sound meter verification regulations.
It is suitable for various routine tests.
Basic configuration: host machine, microphone (TL14423), fan cover, horologe screwdriver, briefcase

Characteristics:
1. digital display, full scale measurement, AC/DC signal output
2. fast and slow time weighting
3. max effective value hold

Specifications:
modal TL5633B
Measuring range 35dB-130dB (A), 40dB-130dB (C)
Frequency weighting A,C
Frequency range 20HZ-12.5kHZ
Sound level setup You can set any range between 40dB-130dB
Detection characteristics True effective value
Digital indication LCD automatic display, resolution ratio 0.1dB,
updating speed 1 time/sec
AC signal output Max effective value : 2v
Impedance: 600Ω
Dc signal output 0.3v-1.3v , changes according to 0.1v/10dB, load
impedance 1MΩ
Sound calibration TL 6020 ( 94dB,1000HZ)
Power DC 7v-9v, with input hole for external power
Service environment Temperature: -10℃-50℃
Humidity: 25%-90% ( at + 40℃)
Atmosphere: 65kPa-108kPa
Dimensions 246mm×70mm×30mm
Weight 0.26kg ( with battery)

Tenlee Group Piezotronics Inc 4


Email: [email protected] WEB: http://www.t-measurement.com
TLND10 sound level meter
It meets IEC 61672 standard, GB/T3785 standard and the second class sound level meter standard of JJG188-2002
sound meter verification regulations.
It is suitable for various routine tests.
Basic configuration: host machine, microphone (TLCH33), fan cover, horologe screwdriver, handbag
Characteristics:
watch hand reading
different level measurement, high resolution, good stability
max value hold (attenuate no more than 2dB/ min)
fast and slow time weighting

Specification
modal TLND10
Measuring range 40dB-130dB (A), 55dB-130dB (C)
Frequency weighting A,C frequency weighting gridding
Frequency range 31.5HZ-8kHZ
Measuring rang attenuator classification error Less than 0.5dB
Meter scale 0dB+10dB,error≤1dB
-5dB~0dB, error≤1dB
Amplifier output Output voltage effective value 2v
Output impedance About 600Ω
Minimum load impedance 10kΩ
Detection characteristics Approximate effective value
Sound calibration TL 6020 ( 94dB,1000HZ)
Electric calibration Amplifier sensitivity is calibrated by internal electric
calibration signal. Accuracy±0.5dB
Power DC 7v-9v, with input hole for external power
Service environment Temperature: -10℃-50℃
Humidity: 25%-90% ( at + 40℃)
Atmosphere: 65kPa-108kPa
Dimensions 254mm×75mm×50mm
Weight 0.4kg ( with battery)

Tenlee Group Piezotronics Inc 5


Email: [email protected] WEB: http://www.t-measurement.com
3. noise integral statistics (frequency spectrum) analyzer

TL6288B noise channel analyzer

It meets IEC 61672 standard and the second class sound level meter standard of JJG188-2002 sound meter verification
regulations.It is suitable for various routine tests.
Basic configuration: main machine, printer (with rechargeable battery), microphone (TL14423), bracket, CD, fan cover,
horologe screwdriver, briefcase
Characteristics:
integral, noise statistics, noise acquisition, noise frequency analysis
built-in 1/1 frequency spectrum filter, RS-232C connector
equipped with printer to realize spot printing
Max hold function, automatic measuring function
Specification
Modal TL6288B
Measuring range A sound level:30-135dB /C sound level:35-135dB/Linearity: 40-135dB
Frequency range 20Hz-12.5kHz
Frequency weighting A,C
Detector characteristics LMS true effective value
Crest factor 3
Time weighting Fast(F), Slow(S), Max value hold function
Measuring time setting Man,10s,1min,5min,10min,15min,20min,1h,4h,8h,24h,regular
Automatic measuring function Leq,L5,L10.L50,L90,Lmax,SD,Ld,Ln,Ldn,1/1 frequency spectrum
Filter characteristics 1/1 frequency interval
centre frequency: 31.5Hz,63Hz,125Hz,500Hz,1kHz,2kHz,4kHz,8kHz
Measured data 500 teams single team+50 teams filter+4 teams regular
automatic storage
Connector RS-232C, can be connected with printer and microcomputer communication
to print measured data and frequency spectrum histogram
Sound calibration TL6020/6020A sound level calibrator 94dB, 1kHz
Display 54mm×42mm LCD digital display, analog watch hand
Display measuring mode, measuring time, clock, 1/1 center frequency
Backlight display function
Power 5 batteries, DC 7.5v, with input hole for external power
Dimensions Main machine: 240mm×81mm×31mm
Printer: 178mm×81mm×31mm
Weight 0.4kg , printer: 0.41kg

Tenlee Group Piezotronics Inc 6


Email: [email protected] WEB: http://www.t-measurement.com
TL6288E multifunction noise analyzer
It meets IEC 61672 standard and the second class sound level meter standard of JJG188-2002 sound meter verification
regulations.
It is suitable for noise test of the environment, public health, transportation
Basic configuration: main machine, printer (with rechargeable battery and external power), microphone (TL14423),
bracket, CD, fan cover, printing paper, cable, briefcase
Characteristics
integration, noise statistics, noise acquisition
equipped with printer to realize spot printing
fast and slow time weighting
Max hold function
automatic measuring function
Specification
Modal TL6288E
Measuring range A sound level:30-135dB C sound level:35-135dB
Frequency range 20Hz-12.5kHz
Frequency weighting A,C
Detector characteristics LMS true effective value
Crest factor 3
Time weighting Fast(F), Slow(S), Max value hold function
Measuring time setting Man,10s,1min,5min,10min,15min,20min,1h,8h,24h,regular
Automatic measuring function Lp,Leq,L5,L10.L50,L90,L95,Lmax,SD,Ld,Ln,Ldn etc.
Clock Can set year, month, date, hour, minute, second
Measured data More than 500 teams,
automatic storage
Connector RS-232C, can be connected with printer and microcomputer to print measured data
Sound calibration TL6020 sound level calibrator Sound pressure level: 94dB, 1kHz
Display 54mm×42mm LCD digital display, analog watch hand
Display measuring mode, measuring time, clock,Backlight display function
Power 5 pieces of LR6 alkaline batteries, DC 7.5v, with input hole for external power
Dimensions Main machine: 240mm×81mm×31mm
Printer: 178mm×81mm×31mm
Weight 0.4kg , printer: 0.41kg

Tenlee Group Piezotronics Inc 7


Email: [email protected] WEB: http://www.t-measurement.com
TL5618A/ 5618A+ integral sound level meter
It meets IEC 61672 standard and the second class sound level meter standard of JJG188-2002 sound meter verification
regulations.
Basic configuration: main machine, microphone (TL14423), output cable, CD, fan cover, horologe screwdriver, and
briefcase

Characteristics:
integral, instantaneous measuring function
clock setup, real time clock display
menu operation, automatic measuring and storage

Specification
Modal TL 5618A
Measuring range 35-130dB(A)
Frequency range 20Hz-10kHz
Time weighting Fast(F), slow(S) , Max hold function
Noise 0~9999% DL
Automatic measuring Lp, Leq, Lmax, Lae, DL(%),L5,L10,L50,L90.L95
Measuring time Automatic:10s,1min,5min,10min,15min,20min,1h,8h,24h
Manual: any time, Max 24h
Clock year, month, date, hour, minute, second
Automatic storage of measured data 1000 teams of single team data, 64 teams of regular data
Connector Data will be transferred to TL4784A printer or computer through
RS-232C connector
Sound calibrator TL6020 (94dB,1000Hz)
Power Five pieces of batteries, with input hole (DC9V)for external
power
Dimensions 307mm×80mm×30mm
Weight 0.4kg (without batteries)

4. precise impulse sound level meter


Tenlee Group Piezotronics Inc 8
Email: [email protected] WEB: http://www.t-measurement.com
TL5660A precise impulse sound level meter octave filter
It meets IEC 61672 standard and the first class sound level meter standard of JJG188-2002 sound meter verification
regulations.
Basic configuration: main machine, microphone, fan cover, horologe screwdriver, briefcase, filter(optional)
Characteristics:
digital and watch hand display, different level measurement
with impulse, it can accurately test lower limit, upper limit impact sound and noise of short duration
can form spectrum analyzer with external filter
Specification
Modal TL5660 series
Measuring range TL5660A: 30dB-138dB(A),40dB-138dB(C),45dB-138dB(linearity)
TL5660B(low level): 20dB-135dB(A),32dB-135dB(C),40dB-135dB(linearity)
TL5660B(high level): 55dB-165dB(A),65dB-165dB(C),70dB-165dB(linearity)
Frequency range 10Hz-20kHz
Frequency weighting A,C, linearity
Detector characteristics True effective value, peak value
Time weighting Fast (F), Slow(S), Impulse (I). Max hold, with AC/DC signal output connector
Can be equipped with filter connector
Overload indication Full scale +10±0.5dB, LED
Power DC 6v, 4 pieces of 1.5v batteries, with external DC voltage input hole
With AC accessories, it can be used to test with external 220v.
Sound calibrator TL 6020 (94dB,1000Hz), TL6020A (94dB/114dB,1000Hz)
It has sine correction signal inside, and can be used for calibration reference
DC,AC output port
Dimensions 290mm×106mm×65mm
Weight 0.67kg(without batteries)

Sound level measuring range TL5660A TL5660B LOW TL5660B HIGH


(2×10-5 Pa)
A 30-138dB 20-135 dB 55-165 dB
C 40-138 dB 32-135 dB 65-165 dB
F 45-138 dB 40-135 dB 70-165 dB

Tenlee Group Piezotronics Inc 9


Email: [email protected] WEB: http://www.t-measurement.com
TL5670B integral impulse sound level meter
TL5670B integral impulse sound level meter is precise acoustics measuring equipment. It meets JJG188-2002 sound
level meter verification standard, IEC60804 and I type sound level meter standard of GB/T17181.
The measured data can be transferred to computers through RC232C connector and communication cable.
It can realize Lp real time communication output and airplane noise Lepn measurement.
It is widely used in environment noise measurement and industrial noise measurement, such as equipment noise,
vehicle noise, vessel noise and electrical equipment noise. It is also widely used in sound measurement field for
departments, such as factories, enterprises, environment protection, labor hygiene, transportation, teaching, scientific
research.
Basic configuration: TL5670B sound level meter, cable, program floppy disk, fan cover, horologe screwdriver, AC
accessories (external power), case
Specification
Modal TL5670B
Microphone 1/2 inch capacitive microphone
Frequency: 20-20kHz; sensitivity: 50mV/Pa
Measuring range Reference:2×10-5Pa
A: 25dB-135dB; C: 35dB-135dB: Linearity: 45dB-135dB
Frequency weighting A, C, linearity
Frequency range 10Hz-20kHz
Time weighting fast(F), slow(S), Max hold
Detector True effective value, crest factor≥10
Automatic measuring and storage Leq, Lae, SD, Lmin, L95, L90, L50, L10, L5, Lmax,
reverberation time T60, Lepn
Automatic acquisition and storage: 200 teams of data single
team
Measuring time setting and clock Man, 10s,1min,5min,10min,20min,30 min,1h,8h,24h
Clock: year, month, date, hour, minute, second
Output interface serial interface RS232C
AC interface: Max effective value 7V, output impedance 600Ω
DC interface: 0.25v-1.35v, 0.1v/10dB
Display 40mm×70mm LCD digital display, 4 digits, resolution 0.1dB
Power Five pieces of LR6 batteries with input hole for external power
Calibrator TL6020/TL6020A sound level calibrator
Dimensions 310mm×85mm×70mm
Weight 680g
Service environment Temperature: -10℃~+50℃ Relative humidity: 20%-90%RH
Pressure: 86kPa~106kPa

Tenlee Group Piezotronics Inc 10


Email: [email protected] WEB: http://www.t-measurement.com
5. individual sound exposure meter

TL5618B individual sound exposure sound level meter

It meets IEC 61672 standard, GB/T 3785,1-2010, and the second class sound level meter standard and individual
sound exposure meter standard of GB/T 15952.

Characteristics:
digital detection, automatic measuring range conversion, wide dynamic range,
LCD digital display
Specification
Modal TL5618B
Microphone Diameter 12.7mm, capacitive microphone, nominal
sensitivity:-32dB/pa
Measuring range A, 38dB- 130dB
Frequency range 20Hz-12.5kHz
Noise exposure 0-19.99(Pa2.h)
Frequency weighting A
Time weighting Fast (F), Slow(S)
Measuring time Manual,10s,1m,5m,10m,15m,30m,1h,4h,8h,24h
Automatic measuring LA, Leq, Lmax, Lae, E, Tm (time of measuring)
4 digits LCD digital display
Power 2 pieces of batteries
Power consumption:25mA more than 24hours
of continuous work
Sound calibrator TL 6020 (94dB,1000Hz)
Dimensions 116mm×61mm×25mm
Weight 160g
Service environment Temperature: 0℃~+50℃
relative humidity: 25%~90%
pressure: 65kPa-108kPa

6. noise automatic measurement and analysis system


Tenlee Group Piezotronics Inc 11
Email: [email protected] WEB: http://www.t-measurement.com
TL5670XB automatic noise measurement system

TL5670XB noise automatic measuring and analysis system is composed of TL5670B integrating impulse sound level
meter, TL5731 filter and printer. The filter meets IEC1260, GB/T3241 standard. The TL5670B sound level meter
meets JJG188-2002 sound level meter verification standard, IEC60804 and I type sound level meter standard of
GB/T17181.
It can analyze 1/1 and 1/3 spectrum. The measured data can be transferred to computers through RC232C connector
and communication cable.
It can realize Lp real time communication output and airplane noise Lepn measurement.
It is widely used in environment noise measurement and industrial noise measurement, such as equipment noise,
vehicle noise, vessel noise and electrical equipment noise.
It is also applied in sound measurement field for departments, such as factories, enterprises, environment protection,
labor hygiene, transportation, teaching, scientific research.
Basic configuration: TL5670B sound level meter, filter, printer, cable, program floppy disk, fan cover, horologe
screwdriver, AC accessories (external power), case

Specification
Modal TL5670B
Microphone 1/2 inch capacitive microphone
Frequency: 20-20kHz; sensitivity: 50mV/Pa
Measuring range Reference:2×10-5Pa
A: 25dB-135dB; C: 35dB-135dB: Linearity: 45dB-135dB
Frequency weighting A, C, linearity
Frequency range 10Hz-20kHz
Time weighting fast(F), slow(S), Max hold
Detector True effective value, crest factor≥10
Automatic measuring and storage Leq, Lae, SD, Lmin, L95, L90, L50, L10, L5,
Lmax, reverberation time T60, Lepn
Automatic acquisition and storage: 200 teams of data single
team
Measuring time setting and clock Man, 10s,1min,5min,10min,20min,30 min,1h,8h,24h
Clock: year, month, date, hour, minute, second
Output interface serial interface RS232C
AC interface: Max effective value 7V, output impedance 600Ω
DC interface: 0.25v-1.35v, 0.1v/10dB
Display 40mm×70mm LCD digital display, 4 digits, resolution 0.1dB
Power Five LR6 batteries with input hole for external power

Tenlee Group Piezotronics Inc 12


Email: [email protected] WEB: http://www.t-measurement.com
Calibrator TL6020/TL6020A sound level calibrator
Dimensions 310mm×85mm×70mm
Weight 680g
Service environment Temperature: -10℃~+50℃
Relative humidity: 20%-90%RH
Pressure: 86kPa~106kPa

7. noise integral average sound level meter

Tenlee Group Piezotronics Inc 13


Email: [email protected] WEB: http://www.t-measurement.com
TL5670A integral average sound level meter

General introduction
It has wide dynamic measuring range, LCD digital display and automatic measuring and storage function.
The built-in filter can analyze 1/1, 1/3 spectrum.
It meets the new standards of national noise measurement.
Measurement results and maps can be automatically printed through RS232C serial port and printer.
The measurement results can be transmitted to computers by communication cable to realize Lp real time
communication output and Lepn measurement and calculation.
It is widely used in environment and industrial noise measurement, such as equipments, vehicle, ships, and electrical
equipments. It is also applied in sound measurement field for departments, such as factories, enterprises, environment
protection, labor hygiene, transportation, teaching and scientific research.
It meets IEC61672, GB/T17181 the first class standard.
Basic configuration: TL5670A main device, microphone, program CD, communication cable, fan cover, external
power, carrying case.

Specification
Modal TL5670A
Microphone 1/2 inch capacitive microphone
Sensitivity: 50mV/Pa; frequency: 10Hz-20kHz
Measuring range Reference: 2×10-5Pa, use different microphone
A: 25dB-135dB can be extended to 20dB-145dB;
C: 30dB-135dB; Linearity: 40dB-135dB
Frequency range 10Hz-20kHz
Frequency weighting A, C, Linearity, Z weighting, Flat frequency response
Time weighting Fast(F), Slow (S), Max hold
Detector LMS detection, crest factor≥10
Built-in filter 1/3 octave, 1/1 octave, 30 teams LED display
1/3(Hz): 25,31.5,40,50,63,80,100,125,160,200,250,315,400,500,630,
800,1k,1.25k,1.6k,2k,2.5k,3.15k,4k,5k,6.3k,8k,10k,12.5k,16k,20k
1/1(Hz): 31.5,63,125,250,500,1k,2k,4k,8k,16k
Measuring range setup Dynamic range >70dB, out-range and under-range automatic indication
Measuring range one: 5dB-70dB;
Measuring rang two: 35dB-105dB(referential measuring range)
Measuring range three: 55dB-125Db

Tenlee Group Piezotronics Inc 14


Email: [email protected] WEB: http://www.t-measurement.com
Measuring range four: 75dB-145dB
Automatic measuring Leq,Lae,SD,Lmin,L95,L90,L50,L10,L5,Lmax,1/3 and 1/1 spectrum
analysis, reverberation time T60,Lepn
Automatic acquisition, storage and printing
Measuring time Man, 10s,1min,5min,10min,20min,30min,1h,8h,24h
and clock Clock: year, month, date, hour, minute, second
Output connector AC output: Max effective value is about 7v, output impedance: 600Ω
DC output: 0.25v-1.35v, (25dB-135dB) 0.1V/10dB
Serial port: RS232C, can be connected with printer and computer
Display 40mm×70mm LCD digital display, 4 digits LCD
Sound calibrator TL6020 sound calibrator (1000Hz, 94dB)
Power DC 5v-8v, 5 pieces of LR6 batteries, with input hole for external power
Dimensions 320mm×85mm×70mm
Weight 0.7kg
Service environment Temperature: -10℃~+50℃
RH: 20%-90%
Pressure: 86kPa-106kPa

8. precise noise frequency spectrum analyzer

Tenlee Group Piezotronics Inc 15


Email: [email protected] WEB: http://www.t-measurement.com
TL5660C noise frequency spectrum analyzer
It meets IEC 61672 Class 1 sound level meter standard, GB3785 Class 1 sound level meter standard, IEC 1260 and
GB/T 3241 octave filter standard.
It adopts digital detection technology.
It is widely used in industrial environment noise measurement and noise spectrum analysis for departments, such as
environment monitor, hygiene and epidemic prevention, labor protection, school teaching, scientific research.
Basic configuration: TL5660C, printer, TL14423, CD, output cable, fan cover, horologe screwdriver, briefcase
Specification
Modal TL5660C
Frequency range 10Hz-20kHz
Frequency weighting A, C, Linearity
Measuring range A:25dB-130dB; C: 30dB-130dB Lin: 40dB-130dB
Measuring range setup Manual
Three levels (L: 23dB-90dB; M: 40dB-110dB; H:70dB-130dB)
linearity range:70dB
Accuracy IEC61672 first class standard; GB3785 first class standard
Time weighting F(fast), S(slow)
Fixed time measurement Lp,Leq,Lae,L5,L10,L50,L90,L95,Lmax,Lmin,SD,Ld,Ln,Ldn
Time setup 10s,1min,5min,10min,15min,20min,1h,4h,8h,regular 24h
Sampling time 31ms
Filter Built-in 1/1 octave
Center frequency 31.5Hz,63 Hz,125 Hz,250 Hz,500 Hz,1k Hz,2k Hz,4k Hz,8k Hz
Display Dynamic LCD display, instantaneous sound level display, analog
electricity meter function
Data storage 500 teams of single team data, 4 teams of regular data, 50 teams of filter
automatically measured data
Output connector AC: alternating voltage signal ,can be used for external analysis
RS232: for printer and computer
Sound calibrator TL6020 sound level calibrator, 1000Hz,94dB
Power Five pieces of batteries, can work continuously for 24 hours
External power:DC9V
Dimensions 307mm×80mm×30mm
Weight 0.386kg (with batteries)

Tenlee Group Piezotronics Inc 16


Email: [email protected] WEB: http://www.t-measurement.com
TL5660D precise noise frequency spectrum analyzer
TL5660D precise noise frequency spectrum analyzer is intelligent noise meter.
It meets IEC61672 standard and GB/T3785.1-2010 Class 1 standard.
It also meets IEC1260 and GB/T3241 octave filter standard.
Specification
Modal TL5660D
microphone 1/2 inch capacitive microphone
Frequency range 10Hz-20kHz
Frequency weighting A, C, Flat (linearity: Z)
Measuring range A: 25dB-130dB C: 30dB-130dB F: 35dB-130dB
Measuring range setup Manual, six levels, linearity: 70dB
10dB-80dB,20dB -90dB,30dB -100dB
40dB -110dB,50dB -120dB,60dB -130dB
Accuracy IEC61672,GB/T3785 class 1
Time weighting Fast(F), slow(S),linearity-averaging
Fixed time measurement Lp,Leq,Lae,E,L5,L10,L50.L90,L95,Lmax,Lmin,SD,Ld,Ln,Ldn
Time setup 10s,1min,5min,10min,15min,20min,30min,1h,4h,8h,24h regular
Sampling time 31ms
reverberation time 0.3s-10s
Filter Built-in 1/1 octave
Center frequency 31.5Hz,63Hz,125Hz,250Hz,500Hz,1kHz,2kHz,4kHz,8kHz,16kHz
Measuring mode STA,24H,OCT,TR
Display Dynamic bar chart display, instantaneous sound level real time
display with 16 times/sec updating rate, analog electricity meter,
under-voltage and overload indication
Data storage Max 2000 teams or 80-days 24H measured data
Output connector AC,DC: output AC,DC signal
RS232: for printer and computer
Calibrator TL6020 sound level calibrator,1000Hz,94dB
Power Six batteries can last 24 hour, can also be connected to external
power DC9V
Dimensions 290mm×80mm×30mm
Weight 480g (including the batteries)

Tenlee Group Piezotronics Inc 17


Email: [email protected] WEB: http://www.t-measurement.com
9. environment vibration analyzer

TL5933A environment vibration level analyzer


Based on TL5933 environment vibration analyzer, TL5933A environment vibration analyzer has additional data
storage, analysis and printing functions. It is a kind of intelligent, light and portable environment vibration automatic
measuring instrument. It is composed of host machine and printer. Its characteristics include automatic measuring
conversion, LCD, maximum value hold, equivalent continuous vibration automatic measuring, and vibration level
statistics. The printer can print all kinds of measuring result. The analyzer meets Ⅱ type vibration testing equipment
standard of ISO8041—1990 Human Response Vibration Meter. It also meets measuring standard of ISO2631 Human
Whole Body Vibration Evaluation and GB10071—88 Urban Environment Vibration Measuring Method. It is widely
used in labor protection, environment protection and industrial & health department vibration measuring.
basic configuration:host machine、printer(with rechargeable batteries)
、input cable、vibration sensor、carrying case
Specification
Modal TL5933A
sensor piezoelectric accelerometer
Voltage sensitivity MAX 400mV/g
Frequency 1~160HZ
Horizontal sensitivity ratio ≤5%
Amplitude linearity <5%
Vibration level measuring range 60~140dB ( 10-6M/S2 as reference)
Frequency range 1~80HZ
Frequency weighting VLZ(the whole body vertical)VLX—Y(the whole body horizontal)
VAL(linearity, accelerometer level)
Time weighting time constant: 1S
Automatic measuring function When measuring time is set Man、10s、1m、5m、10 m、15 m、
20 m、1h、8h、24h or 24h o’clock,it can store(127 groups) ,display
and print the following data: maximum instant vibration level
maintenance and overload indication, equivalent continuous vibration
level VLEQ value and vibration level statistics VL10,VL50,VL90,
VLMIN,VLMAX,standard deviation SD.
time setup year, month, date, hour, minute
display 4 digits LCD digital and signal display
reference calibration inner electrical signal
power supply DC 7.5V, external power input jack
dimensions host machine:240mm×81mm×31mm
printer:178mm×81mm×31mm
weight host machine: 400g,printer: 410g

Tenlee Group Piezotronics Inc 18


Email: [email protected] WEB: http://www.t-measurement.com
10.mechanical vibration tester

TL5936 vibration tester

TL5936 vibration meter is a kind of digital and portable vibration measuring instrument. It can directly measure
vibration acceleration, vibration intensity (velocity), hand transmitted vibration frequency weighting acceleration
value. It has a wide measuring range and can maintain maximum value. It can provide DC, AC output to allow other
analysis and testing instruments to analyze further. It is mainly used in machine vibration testing to evaluate machine
vibration intensity. It can also be used in handheld tools (chain saw, gadder, air picker) vibration testing to evaluate
handheld tools’ impact on human. Both of the vibration acceleration and vibration velocity measuring meet ISO2372
and ISO2373 standards and other relevant national standards. Hand transmitted vibration measuring meets ISO5439
and GB/T14790 standard. The instrument performance meets ISO8041 standard.
This instrument provides convenience for departments (such as mechanical design, mechanical manufacturing,
electric power, equipment management, labor protection, transportation, environment protection) to monitor
equipment failure and aging signal online, control products quality, measure vibration test, control vibration, evaluate
hand transmitted vibration.
Specification

Modal TL5936
vibration sensor piezoelectric accelerometer
charge sensitivity: 4 PC/ms-2 frequency: 1Hz~10 000Hz
maximum measurable acceleration: 2000m/s2
measuring range measuring range is divided to high level (H) and low level (L),
manual level change, for details, pls check table 1
hand transmitted vibration frequency weighting ISO/DIS8041 standard
detection characteristics true effective value, peak value, peak-to-peak value
display 4.5 digits LCD display, Max hold
Display period is 1 second
DC,AC output Φ3.5 two channels socket output, output impedance is 2kΩ
Full scale output is about 2V effective value
Accuracy 5%
power supply external DC power: DC 9V
internal battery: 7.5 V,5 LR6 alkaline batteries.
Dimensions 237mm × 81mm × 34 mm
Weight about 400g(including sensor and magnetic fix tip)
Service environment temperature: -10℃~50 ℃
relative humidity: 20%~90% RH

Tenlee Group Piezotronics Inc 19


Email: [email protected] WEB: http://www.t-measurement.com
TL5944 vibration tester
TL5944vibration detector is a kind of digital, small mechanical vibration testing instrument. It can easily test
vibration acceleration, velocity, displacement and other vibration parameters. Its main performance meets ISO2954
standard. It can make reliable quantitative evaluation of rotary and reciprocating machine vibration by IS02372、
ISO2373 regulated methods. This instrument provides convenience for departments (such as mechanical design,
mechanical manufacturing, military industry, electric power, equipment management, transportation, environment
protection) to monitor equipment failure and aging signal online, control products quality, measure vibration test,
control vibration.
Specification
Modal TL5944
vibration sensor piezoelectric accelerometer,charge sensitivity: 3PC/ms2
measuring range 1.acceleration: a:0.1 m/S2 ~199.9m/S2 f:5 Hz~10000Hz(-3dB)

2.velocity: v:0.01 cm/s ~19.99cm/s f:10 Hz~1000Hz

3.displacement: d: 1μm~1999μm f:10 Hz ~1000Hz

detection true effective value, peak value, peak-to-peak value


characteristics

output display 3.5 digits LCD,equipped with maximum value maintenance value.

Display period is about 1 second.


analog output ¢3.5two-pin socket, full scale output 2V effective value
accuracy better than ±5%±2 digits
power supply DC9V、6F22 battery
dimensions 138mm×65mm×29mm
weight 290g

11.sound level meter calibrator


Tenlee Group Piezotronics Inc 20
Email: [email protected] WEB: http://www.t-measurement.com
TL6020A sound level meter calibrator
It is mainly used as sound pressure calibrator for microphone, sound level meter, noise analyzer and other sound
measuring equipment.
It meets IEC 60942 and GB/T 15173 class 1.
Basic configuration: main machine, battery, verification certificate, inspection certificate, instruction manual
Modal TL6020A
Sound pressure level 94dB and 114dB
Calibration frequency 1000HZ±1%
Sound pressure level accuracy 1
±0.2dB(+23℃), ±0.3dB(-10℃~+50℃)
Harmonic distortion ≤1%
Power 1×6F22 battery
Dimensions Φ48mm×110mm
Weight About 0.3kg (including battery)

TL6020 sound level meter calibrator


It is used to calibrate the sound pressure for all of our microphone and sound measuring equipment.
It meets IEC 942 class 1 sound calibrator standards.
Basic configuration: main machine, dispenser, battery, verification certificate, packing box
Modal TL6020
Sound pressure level 94dB (2×10-5 Pa)
Frequency 1000HZ±2%
Sound pressure level accuracy ±0.3dB(20℃±5℃)
±0.5dB(0℃±40℃)
Harmonic distortion ≤3%
Power 9V laminated cell
Delay time About 1 minute
Dimensions Φ41mm×92mm
Weight About 0.287kg (including battery)

Modal Polarization Frequency Sensitivity feet Type characteristics


Voltage Range(HZ) (Mv/pa)
TL14423B 0v 20-12.5K 35 1/2 Sound Use with
field 5633,5618,6288
TL14423E 0v 20-20K 50 1/2 Sound Use with I type
field
microphone TL14427 0v 20-20K 45 1/2 Sound Use with 5670B
field

12.octave filter

Tenlee Group Piezotronics Inc 21


Email: [email protected] WEB: http://www.t-measurement.com
TL5731 1/3 octave filter
It meets GB/T3241 octave and fraction octave filter standard, IECDUB225, ANSIS1, ⅡCLASS 11
It can directly connect synchronous input and output signal provided by TL5670 sound level meter without external
cables
Frequency conversion is controlled by electronic switches. For example, if you want to use linearity characteristics,
push “ALL PASS” button.
Usually, it analyzes the frequency at the “FLAT” of the sound level meter, but it analyzes the frequency at “A”
weighting while using the filter.
Connected with electrical level recorder, it can automatically analyze the frequency synchronously with the recorder.
It is powered by TL5670 internal power.
Push “GAIN” button to amplifier the signal 20dB to read much lower sound pressure level value.

Main technical data:


frequency:20HZ-20KHZ ( 30 passing bands)
Centre frequency: 25, 31.5, 40, 50, 63, 80, 100, 125, 160, 200, 250, 315, 400, 500, 800, 1k, 1.25k, 1.6k, 2k, 2.5k,
3.15k, 4k, 5k, 6.3k, 8k, 10k, 12.5k, 16k, 20k and all pass
Measuring range: >50dB
Centre frequency set: push button or use an electrical level recorder that can use binary code
Centre frequency display: 31 LED indicators
Power: powered by sound level meter
Dimensions and weight: 5cm×10cm×8cm 0.7kg

Tenlee Group Piezotronics Inc 22


Email: [email protected] WEB: http://www.t-measurement.com
TL5721 1/1 octave filter
It meets GB/T3241 octave and fraction octave filter standard, IECR225
It can directly connect synchronous input and output signal provided by TL5670 and TL5660 sound level meter
without external cables
Frequency conversion is controlled by electronic switches. For example, if you want to use linearity characteristics,
push “ALL PASS” button.
Usually, it analyzes the frequency at the “FLAT” of the sound level meter, but it analyzes the frequency at “A”
weighting while using the filter.
With serializable binary code, it can analyze the frequency spectrum synchronously with the recorder.
It is powered by TL5670 and TL5660 internal power.
Push “GAIN” button to amplifier the signal 20dB to read much lower sound pressure level value.

Main technical data:


frequency:31.5HZ-16KHZ (10 passing bands)
Centre frequency: 31.5, 63, 125, 250, 500, 1k, 2k, 4k, 8k, 16k and all pass
Measuring range: >50dB
Centre frequency set: push button or serializable binary code
Centre frequency display: 11 LED indicators
Power: powered by sound level meter
Dimensions and weight: 5cm×10cm×8cm 0.306kg

Tenlee Group Piezotronics Inc 23


Email: [email protected] WEB: http://www.t-measurement.com

You might also like