Power Socket
Power Socket
User Manual
Downloaded from www.Manualslib.com manuals search engine
GSM POWER SOCKET USER MANUAL
GSM Power Socket is mainly applied for house and office usage. It is
not suited for industry application, especially in humidity or dust
condition.
4
Downloaded from www.Manualslib.com manuals search engine
GSM POWER SOCKET USER MANUAL
Exception clause
1. We operate on a policy of continuous development. We reserve the
right to make changes and improvements to any of the sockets
described in this document without prior notice.
2. We don’t guarantee for the document veracity, reliability or any
content except regulate in proper laws. Including no guarantee for
socket suitable market or suitable area promise.
3. We hold no responsibility for the illegal use of this socket.
4. We hold no responsibility for any loss of income or any special,
incidental, consequential or indirect damages howsoever caused.
5. The contents of this document are provided “as is”. Except as
required by applicable law, no warranties of any kind, either
expressed or implied, including, but not limited to the accuracy,
reliability or contents of this document. We reserve the right to revise
this document or withdraw it at any time without prior notice.
6
Downloaded from www.Manualslib.com manuals search engine
GSM POWER SOCKET USER MANUAL
7
Downloaded from www.Manualslib.com manuals search engine
GSM POWER SOCKET USER MANUAL
8
Downloaded from www.Manualslib.com manuals search engine
GSM POWER SOCKET USER MANUAL
GSM (Blue)
Flash Be busy or searching GSM network.
light
Constant
Successfully load to GSM network.
light
Constant
The socket outlet has power supply.
Output (Red) light
light
Turning off The socket outlet cuts power supply.
10
Downloaded from www.Manualslib.com manuals search engine
GSM POWER SOCKET USER MANUAL
11
Downloaded from www.Manualslib.com manuals search engine
GSM POWER SOCKET USER MANUAL
12
Downloaded from www.Manualslib.com manuals search engine
GSM POWER SOCKET USER MANUAL
Important note
If GSM Power Socket is being used for the first time, or it has been
reset, the Master user must adjust the socket time according to
the current time of SMS center. Otherwise, GSM Power Socket will
use the original time from 00:00:00, 1st.Jan.2004.
Method
The Master user sends following SMS message in order to:
Regulate the socket time: #152#SIMCardNumber# (1)
The SIMCardNumber should be the SIM card number of GSM
Power Socket .
14
Downloaded from www.Manualslib.com manuals search engine
GSM POWER SOCKET USER MANUAL
15
Downloaded from www.Manualslib.com manuals search engine
GSM POWER SOCKET USER MANUAL
Master user:
Only one Master user has authorization to use all features of GSM
Power Socket.
In order to enable all the functions on the socket, the Master user
must store his/ her mobile number in the socket’s memory. Only one
Master’s mobile number (Master number) is allowed for a socket.
Family users:
There are four Family users have authorization to use two
commands of switch on or cut off the socket output.
The other mobile phone users have no authorization to use GSM
Power Socket .
16
Downloaded from www.Manualslib.com manuals search engine
GSM POWER SOCKET USER MANUAL
GSM Power Socket will reply to the user after it receives the SMS
command.
Note
The “#” symbol must not be ignored when typing an SMS
command.
No allow any space within the commands.
18
Downloaded from www.Manualslib.com manuals search engine
GSM POWER SOCKET USER MANUAL
Method
The Master user sends following SMS message in order to:
Delete a family number: #113#FamilyNumber# (6)
Delete several family numbers simultaneously:
#113#FamilyNumber1#…#FamilyNumber4# (7)
Delete all family numbers: #113# (8)
Method
The Master user sends following SMS message in order to:
Switch on the socket output manually: #01# (10)
Cut off the socket output manually: #02# (11)
The Family users send following SMS message in order to:
Switch on the socket output manually: #01#Password# (12)
Cut off the socket output manually: #02#Password# (13)
Password should be 4 digits password number. Default 1234.
SMS reply will be also sent to Master user when Family users use
these two commands to change the socket output successfully.
Successful SMS reply
Status: ON/OFF
Temp:**
Temp control: function ON/OFF
Schedule control: function ON/OFF
Delay control: function ON/OFF
Keep press M button on the GSM Power Socket for half a second.
The OUTPUT indecator light will turn on or off to indicate that
GSM Power Socket output is switching on or off.
The SMS reply is same with Chapter 3.2.1.
Description
If the Master user calls GSM Power Socket , the socket output will
20
Downloaded from www.Manualslib.com manuals search engine
GSM POWER SOCKET USER MANUAL
21
Downloaded from www.Manualslib.com manuals search engine
GSM POWER SOCKET USER MANUAL
Method
The Master user sends following SMS message in order to:
Delay switching on the output after a certain minutes:
#138#1#Minutes# (16)
Delay switching off the output after a certain minutes:
#138#0#Minutes# (17)
Minutes are time parameters, its range is 0-720,
When Minutes is 0, the “delayed switch on/off the socket” function
will be invalid, but the current output status won’t be changed.
Successful SMS reply
Status: ON/OFF
Output will switch off/on after * minutes.
Description
The output of GSM Power Socket can be set to switch on for a
duration and then be switch off after the duration.
If the socket output status is changed manually (including pressing
M button, sending SMS and making phone call), the preset timing,
delaying or temperature control of the socket will be invalid
automatically, but the setting time range parameters will be saved
until GSM Power Socket is reset to factory settings. If these functions
need to be restarted, the following SMS commands must be set:
Timing #128#1#, Temperature control #159#1#, “delayed switch
on/off the socket” commands need to be reset.
22
Downloaded from www.Manualslib.com manuals search engine
GSM POWER SOCKET USER MANUAL
Method
The Master user sends following SMS message in order to:
Enable timing switch on the output: #128#1# (18)
Successful SMS reply
Schedule control: function ON
WorkDay, StartTime-EndTime
If the value of the “WorkDay, StartTime, EndTime” on the SMS
reply are all 0, it means the time duration has not been set. (Refer
to 3.4.2)
Then GSM Power Socket will keep switching on or off the output
automatically according to the schedule settings.
Description
After successful setting of time duration to switch on the socket
output, the schedule parameter will be saved on the socket until
GSM Power Socket is reset to factory settings.
But the “timed switch on the output” feature is applied only when
command 17 be set.
Method
The Master user sends following SMS message in order to:
Set time period to switch on the output:
#129#WorkDay#StartTime#EndTime# (19)
WorkDay: one digit, the values lie in the range of “0” to “8”.
The following table contains the descriptions of each value:
23
Downloaded from www.Manualslib.com manuals search engine
GSM POWER SOCKET USER MANUAL
5 Friday
6 Saturday
7 Everyday
8 Monday to Friday
The socket output will switch on at the StartTime and cut off at the
EndTime.
Method
The Master user sends following SMS message in order to:
Disable timing switch on the output: #128#0# (20)
Successful SMS reply
Schedule control: function OFF
WorkDay, StartTime-EndTime.
Description
The external temperature sensor must be inserted into the I/O port
of GSM Power Socket. The output status of the socket can be
controlled by the environmental temperature automatically.
If users don’t open the “timed switch on the socket” or “delayed
24
Downloaded from www.Manualslib.com manuals search engine
GSM POWER SOCKET USER MANUAL
switch on/off the socket” functions, the socket will control to switch
on or cut off the output according to temperature setting.
If users open the “timed switch on the socket” or “delayed switch
on/off the socket” functions, the temperature control function will only
be valid when power output is switch on (including timed switch on
or delayed switch on time period).
For example: GSM Power Socket is used for the power control of the
heating apparatus. If users set the socket output on when indoor
temperature is bellow 20 degrees and off when indoor temperature
is above 28 degrees. Meanwhile, users set the GSM Power Socket
output is on from 9am to 5pm. In this case, the socket will control to
switch on or off the output according to indoor temperature
automatically from 9am to 5pm duration.
Method
The Master user sends following SMS message in order to:
Enable auto-control the output by temperature: #159#1# (21)
Successful SMS reply
Status: ON/OFF
Temp control: function ON
Temp: **
Mode: Heating/Cooling
Range: LowTemp ~ HighTemp
Description
After successful setting of temperature range, the temperature
parameter will be saved on the socket until GSM Power Socket is
reset to factory settings.
Method
The Master user sends following SMS message in order to:
26
Downloaded from www.Manualslib.com manuals search engine
GSM POWER SOCKET USER MANUAL
Description
A range of temperature can be pre-set onto the socket. In this case,
if the surroundings temperature is detected out of the pre-set
temperature range, the GSM Power Socket will auto-send the SMS
alarm message to master’s mobile phone.
This feature depends on the temperature sensor.
Method
The Master user sends following SMS message in order to:
Enable over-temperature alarm: #170#1# (24)
Set limits of temperature: #170#MinTemp#MaxTemp# (25)
MinTemp and MaxTemp: The values can be set within the range of
-10 to 50 centigrade degree.
Default MinTemp is 20 and MaxTemp is 30 centigrade degree.
27
Downloaded from www.Manualslib.com manuals search engine
GSM POWER SOCKET USER MANUAL
Description
A time period value and temperature changing value can be pre-set
onto the socket. In this case, if the surroundings temperature change
to the pre-set value within the pre-set time period, a SMS alarm
message will be auto-sent to master’s mobile phone.
This feature depends on the temperature sensor.
Method
The Master user sends following SMS message in order to:
Enable the temperature rapid changing alarm: #160#1# (27)
Set time period and temperature changing value:
#160#Temp#Time# (28)
Temp: The values lie in the range of 1 to 50 centigrade degree.
Time: The values lie in the range of 1 to 300 minutes.
Default Temp is 2 degree and Time is 1 minute.
Disable the temperature rapid changing alarm: #160#0# (29)
Successful SMS reply
Fast temperature changing.: function ON/OFF
Delta:**
Time:* minutes
30
Downloaded from www.Manualslib.com manuals search engine
GSM POWER SOCKET USER MANUAL
31
Downloaded from www.Manualslib.com manuals search engine
GSM POWER SOCKET USER MANUAL
32
Downloaded from www.Manualslib.com manuals search engine
GSM POWER SOCKET USER MANUAL
Chapter 4 Maintenance
Try to keep the GSM Power Socket and all its accessories
dry. Do not store and use it in the bathroom, or other
place with high humidity. Do not allow pour water or other
liquids into the socket, otherwise, it might cause
malfunctions.
34
Downloaded from www.Manualslib.com manuals search engine
GSM POWER SOCKET USER MANUAL
General
No. Possible Reason Solution
Trouble
SIM card PIN code
Close the PIN code.
actives.
Contact with local
SIM card invalid.
operator to check of it.
The master
Other master is Change Master
number
7 already set in the number or recover to
already
socket. factory default setting.
exists.
Invalid
format. Refer to the user
8 Invalid command.
Please check manual.
and try again.
No Use the Master
9 authorization mobile phone to try
user the command again.
35
Downloaded from www.Manualslib.com manuals search engine
GSM POWER SOCKET USER MANUAL
110~230V/50HZ,
Input power socket
CEE 7/7 hybrid Schuko/French plug
External temperature
-10℃~50℃
sensor
GSM850, EGSM900,
GSM working band
DCS1800 ,PCS1900 Optional
36
Downloaded from www.Manualslib.com manuals search engine
GSM POWER SOCKET USER MANUAL
39
Downloaded from www.Manualslib.com manuals search engine
GSM POWER SOCKET USER MANUAL
40
Downloaded from www.Manualslib.com manuals search engine