E14F05P03

Twin Diplexer, 2S-DPX D2-800/900 DC Bypass at 800MHz port, 4.3-


10 connectors

New 4.3-10 connectors for improved PIM performance and size reduction
Industry leading PIM performance
Twin configuration
Designed for network modernization application, introduction of LTE700 and LTE800 on
existing site
dc/AISG pass-through on low frequency ports

Product Classification
Product Type Diplexer

General Specifications
Product Family CBC789

Color Gray

Common Port Label PORT 3 COMMON

Modularity 2-Twin

Mounting Pole | Wall

Mounting Pipe Hardware Band clamps (2)

RF Connector Interface 4.3-10 Female

RF Connector Interface Body Style Long neck

Dimensions
Height 130 mm | 5.118 in

Width 210 mm | 8.268 in

Depth 156 mm | 6.142 in

Mounting Pipe Diameter Range 40–160 mm

Page 1 of 4

©2020 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: September 18, 2020
E14F05P03
Outline Drawing

Electrical Specifications
Impedance 50 ohm

License Band, Band Pass APT 700 | CEL 900 | EDD 800 | LMR 800

Electrical Specifications, dc Power/Alarm


dc/AISG Pass-through Method Factory set

dc/AISG Pass-through Path Branch 1 | Branch 2

dc/AISG Pass-through, combiner Branch 1 | Branch 2

Lightning Surge Current 5 kA

Lightning Surge Current Waveform 8/20 waveform

Page 2 of 4

©2020 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: September 18, 2020
E14F05P03
Electrical Specifications
Sub-module 1|2 1|2
Branch 1 2
Port Designation PORT 1 694-862 PORT 2 880-960
License Band APT 700, Band Pass CEL 900, Band Pass
EDD 800, Band Pass
LMR 800, Band Pass

Electrical Specifications, Band Pass


Frequency Range, MHz 694–862 880–960
Insertion Loss, typical, dB 0.2 0.2
Return Loss, typical, dB 22 22
Isolation, minimum, dB 50 50
Input Power, RMS, maximum, W 300 300
Input Power, PEP, maximum, W 3000 3000
3rd Order PIM, typical, dBc -160 -160
3rd Order PIM Test Method Two +43 dBm carriers Two +43 dBm carriers

Block Diagram

Environmental Specifications
Operating Temperature -40 °C to +65 °C (-40 °F to +149 °F)

Corrosion Test Method IEC 60068-2-11, 30 days

IEC 60529:2001, IP67 Page 3 of 4

©2020 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: September 18, 2020
E14F05P03
Ingress Protection Test Method IEC 60529:2001, IP67

Packaging and Weights


Included Mounting hardware

Volume 4.2 L

Weight, net 5.7 kg | 12.566 lb

Regulatory Compliance/Certifications
Agency Classification
ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system