Apartment Fire Case Study: Anusha Residency, Pashan.: Memento Vivere

Anusha Residency in Pashan, India implements robust fire safety measures including two dedicated fire escapes, a large refuge area, a fire detection system, and fire equipment. Regular fire drills and maintenance of systems help prepare residents. The building facilitates safe evacuation with multiple egress points, a strategically located refuge area, and prompt detection and response to potential fires.

Uploaded by

Manav Joshi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
22 views1 page

Apartment Fire Case Study: Anusha Residency, Pashan.: Memento Vivere

Anusha Residency in Pashan, India implements robust fire safety measures including two dedicated fire escapes, a large refuge area, a fire detection system, and fire equipment. Regular fire drills and maintenance of systems help prepare residents. The building facilitates safe evacuation with multiple egress points, a strategically located refuge area, and prompt detection and response to potential fires.

Uploaded by

Manav Joshi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Fire Safety Case Study: Anusha within the building.

the building. This area is outbreak, potentially preventing it from escapes, and other safety equipment are
MEMENTO
Residency, Pashan 411021 strategically located to facilitate spreading. conducted to ensure their effectiveness VIVERE
temporary shelter for residents during a and reliability.
Introduction: fire emergency. The refuge area is Fire Safety Training and Drills: Regular MANAV B. JOSHI
Anusha Residency, located in Pashan designed to be fire-resistant and fire safety training sessions and Conclusion: 1800701040
FOURTH YR. BARCH.
411021, is a multi-story residential equipped with communication systems to evacuation drills are conducted for Anusha Residency in Pashan 411021 is a
building designed with stringent fire stay in contact with first responders or residents, ensuring that they are aware of stellar example of a residential building
safety measures. This case study delves building management. Residents can the escape routes, the proper use of fire that prioritizes the safety and well-being
into the fire strategies implemented at congregate in this space until it is safe to safety equipment, and how to react in of its residents by implementing robust
Anusha Residency, highlighting key evacuate the building or receive further case of a fire. These drills help create a fire safety measures. With two dedicated NORTH
TYPICAL PLAN:

features, including two designated fire instructions. sense of preparedness and improve fire escapes and a substantial refuge GEO LOCATION:

escapes and a substantial refuge area, response times in emergencies. area, alongside a comprehensive array of
that ensure the safety and well-being of Fire Detection and Alarm System: The fire safety systems and equipment,
its residents. building is outfitted with a state-of-the-art Maintenance and Inspections: Anusha residents are well-prepared to respond to
fire detection and alarm system. Smoke Residency places a strong emphasis on fire emergencies. Regular training and
Fire Safety Features: detectors and heat sensors are routine maintenance and inspections of maintenance further enhance the
strategically placed throughout the its fire safety systems. Regular checks building's fire safety standards, making it
Two Dedicated Fire Escapes: Anusha building, triggering alarms in case of and testing of alarms, extinguishers, fire a secure and comfortable place to call
Residency has installed two distinct fire smoke or rising temperatures. The alarm home.
escapes, strategically positioned to allow system is connected to a centralized
for quick and safe evacuation in the event control panel that alerts the local fire
of a fire emergency. These fire escapes department and building management,
are conveniently accessible from multiple enabling swift response to any potential
floors, ensuring that residents have fire hazard.
multiple egress points. They are
SPECIFIC AREAS
well-marked and equipped with Fire Extinguishers and Hose Reels:
emergency lighting, making them easily Anusha Residency ensures that fire
visible and functional even in low-light extinguishers and hose reels are readily
conditions. available on every floor, and especially
near common areas. This allows for
PROJECT NAME:
Huge Refuge Area: Anusha Residency immediate action by residents or staff RESIDENCY FIRE STUDY
boasts a generously-sized refuge area members in the event of a small fire
STUDENT NAME :

MANAV B. JOSHI
PROFESSOR / MENTOR :

PLAN TYPE:

APARTMENT FIRE TOTAL SHEETS: PLAN NUMBER:

06

CASE STUDY : SUBJECT:

BUILDING SERVICES

ANUSHA RESIDENCY,
PASHAN. SCALE
1:100
SEMESTER VII

SIGN

ANNOTATION

METERS

DATE

10/10/23