BLF Emergency

Download as pdf or txt
Download as pdf or txt
You are on page 1of 86

EMERGENCY LIGHTING

PRODUCT CATALOGUE
1
www.bes-a.com
ABOUT US

Beş A, one of the leading enterprises engaged in the design and manufacturing in the lighting
electronics in Turkey, was founded in 1995. Beş A started production with electronic ballasts
and expanded its product range with emergency lighting kits, emergency exit luminaires and
emergency lighting fixtures in 1999, considering the needs of our country. Having completed
many innovative projects with its 25 years of knowledge and experience, Beş A responds to the
needs of the emergency lighting products of the sector with its wide product range of up to 500
products in nearly 50 product groups. With its expert staff of 50 people, it operates in a 2500 m2
closed area in Beykoz.

Beş A always aims to produce new technologies, carries out its mechanical and electronic
designs in its own TÜV Rheinland certified R & D laboratory.

Our company attaches importance to public, industry and university collaborations in product
design and development. Moreover, develops new products related to emergency lighting kit and
emergency exit luminaires with embedded software and original circuit design with the support
of TUBITAK.

Our company, which takes a significant part of its power from the principle of “sustainable
development” and its employees working in line of this principle, aims to generate value for a
bright future; and serves with the vision of being the leader in the regions where we operate
with our products and services, and with the mission of making R & D and production in
emergency lighting electronics.

Its strategic objectives are to build high-performing teams; to develop sustainable business
partnerships with the most effective and competent institutions, to produce high quality /
price performance products in accordance with standards by using cutting-edge technology,
to provide customer-oriented solutions, to differentiate in competition in domestic and
international markets, to make zero defect and traceable production, to continuously improve
design and production methods; its values are, being ethical, respectful and friendly with a team
spirit, giving importance to ethical values, being sensitive to the environment, giving importance
to employee and human health and giving importance to education and continuous development
culture.

Our product’s quality is registered by international certification bodies such as TSE, TÜV
Rheinland and BSI. Our company has also ensured quality management systems with ISO 9001
standards.
INDEX

EMERGENCY LIGHTING SOLUTIONS - OVERVIEW


Emergency Lighting Units 10
Emergency Exit Luminaires 14
Emergency Lighting Luminaires - LED 18
Battery User’s Manual 25

WIRELESS EMERGENCY LIGHTING MONITORING SYSTEM - WELCO


WELCO - Overview 30
Emergency Lighting Units - LED 34
Emergency Exit Luminaires - LED 36
Emergency Lighting Luminaires - LED 46

WIRED EMERGENCY LIGHTING MONITORING SYSTEM - ELCO


ELCO - Overview 62
Emergency Lighting Units - LED 64
Emergency Exit Luminaires - LED 66
Emergency Lighting Luminaires - LED 76

SELF-CONTAINED EMERGENCY LIGHTING UNITS


Emergency Lighting Units - LED 94
Emergency Lighting Units - Fluorescent Lamp 112
Emergency Lighting Units - Halogen 116

SELF-CONTAINED EMERGENCY EXIT LUMINAIRES


Emergency Exit Luminaires - LED 120

SELF-CONTAINED EMERGENCY LIGHTING LUMINAIRES


Emergency Lighting Luminaires - LED 142
Emergency Lighting Luminaires - Halogen 162

STANDARDS & ICONS


Standards & Icons 167
EMERGENCY LIGHTING SOLUTIONS

OVERVIEW

9
EMERGENCY LIGHTING UNITS

EMERGENCY LIGHTING UNITS THE EMERGENCY LUMEN FACTOR (BLF, EBLF)


An emergency lighting unit is an electronic circuit that provides adequate lighting to the surroundings in the case of a The emergency lumen factor or the emergency ballast lumen factor is the ratio of the light level transferred to the light
power failure, by the help of the battery it has, provided that it is connected to light sources such as LED, fluorescent and sources such as LED, fluorescent and halogen by the emergency lighting unit in the case of an emergency to the light level
halogen used for general lighting. An emergency lighting unit must be fed from a non-switched phase. It tracks power of the light source under normal operation. It is stated as a percentage (%) in catalogues.
outage from its own feed ends. In the case of a power failure, it prevents panic and provides the necessary lighting for the
fastest evacuation possible from the surroundings. When emergency lighting units produced for LED, fluorescent or certain low voltage halogen lamps become active, they
switch on the lamp not with its normal illumination capacity but with the emergency illumination level, which is lower. Since
Beş A provides up to standard solutions for all types of light sources in the domain of battery operated emergency lighting the purpose is to provide lighting at the illumination level set by the standards that allows the evacuation of the building,
units. the lamp must not be switched on at full power. When designing with emergency lighting units in the emergency lighting
system, if the emergency lumen factor is high, then this has an effect to reduce the number of compulsory devices to be
used.
Emergency Lighting Unit - LED
An Emergency Lighting Unit - LED is an electronic circuit that prompts LED lamps to illuminate the surroundings in the
case of an emergency. The usage of LED based lighting systems increase rapidly day by day. In this segment Beş A provides
tailored solutions for its customers with its products LED fluorescent, LED downlight, LED spot, LED panels and LED STANDALONE EMERGENCY LIGHTING LUMINAIRE
sticks.
A standalone emergency lighting luminaire is a lighting luminaire with own battery, charge circuit, power voltage controller
and lamp driver circuit. It can be obtained by installing an emergency lighting unit in a regular lighting luminaire. This
method is obligatory in first and second-degree earthquake zones.

The light source can be a fluorescent, LED, compact fluorescent or low voltage tungsten halogen lamp. In the systems
where standalone lighting luminaires are used, the installation is quick, the cable installation cost is low and increasing
the capacity is easy. They are compatible with architectural variations.

Emergency Lighting Unit - Fluorescent Lamp


An Emergency Lighting Unit - Fluorescent Lamp is an electronic circuit that prompts fluorescent lamps to illuminate the
surroundings in the case of an emergency. Beş A offers emergency lighting unit solutions complying with all power levels
for 4-pin T8, T5, PLL and PLC fluorescent lamps.
LOCATIONS WHERE THE USE OF AN EMERGENCY LIGHTING SYSTEM IS COMPULSORY

• Gathering points
• All escape and exit routes
• Elevators and escalators
• Hospitals and nursing homes
• Schools and other buildings for education
• Hotels and dormitories
Emergency Lighting Unit - Halogen Lamp • Indoors car parks
• Gas stations
Emergency Lighting Unit - Halogen Lamp is an electronic circuit that prompts 12 V halogen lamps to illuminate the • All buildings with a occupant load of 200 or more
surroundings in the case of an emergency. • Buildings with 50 or more occupants under the ground level
• Buildings without windows
• Tall buildings
• Areas where fire alarm buttons and fire cabinets are located
• Areas where first aid and safety kits are located
• Workshops and laboratories where machinery in motion and chemicals that pose high risk are located
• Electricity distribution and generator rooms
• Central battery unit rooms

11
EMERGENCY LIGHTING UNITS EMERGENCY LIGHTING UNITS

EMLUS-SLED Compatible With EMLUS-220 (SPOT) Compatible With

• LED Downlight
• COB LED
• LED Strip
• LED Stick • LED Spot Lamp
• Power LED
• LED Spot Lamp
• Panel LED

EMLUS-SLED is suitable for the luminaire with external LED driver that has 3 ... 200 VDC output EMLUS-220 (SPOT) is suitable for 3 W and 5 W LED spot lamps that operate on 220 V. It
voltage. It feeds the LEDs with 10 ... 63 mA output current in the case of emergency. provides the same light as in operation on main power in the case of emergency.

EMLUS-LED Compatible With EMLUS-FLS Compatible With

• LED Downlight
• COB LED • T5 Circular Fluorescent Lamp
• LED Strip • T5 Fluorescent Lamp
• LED Stick • T8 Fluorescent Lamp
• Power LED • PLL Compact Fluorescent Lamp
• LED Spot Lamp • PLC Compact Fluorescent Lamp
• Panel LED

EMLUS-LED is suitable for the luminaire with external LED driver that has 3 ... 150 VDC output EMLUS-FLS is suitable for 4-pin T5-T8-PLL-PLC fluorescent lamps.
voltage. It feeds the LEDs with 10 ... 63 mA output current in the case of emergency. It is compatible with electronic and mechanic ballasts.

EMLUS-12V/24V Compatible With EMLUS-FLT Compatible With

• T5 Circular Fluorescent Lamp


• LED Strip • T5 Fluorescent Lamp
• LED Stick • T8 Fluorescent Lamp
• LED Spot Lamp • PLL Compact Fluorescent Lamp
• PLC Compact Fluorescent Lamp

EMLUS-12/24V is suitable for LED strip applications up to 12V-50W / 24V-100W. It provides EMLUS-FLT is suitable for 4-pin T5-T8-PLL-PLC fluorescent lamps.
the same light as in operation on main power in the case of emergency. It is compatible with electronic and mechanic ballasts.

EMLUS-220 Compatible With EMLUS-1250 Compatible With

• Spot Halogen
Lamp
• LED Spot Lamp
• G9 Halogen
• LED Tube
Lamp
• LED Lamba
• AR 111 Halogen
Lamp

EMLUS-220 is suitable for LED spot, LED tube, panel luminaires, that operates on 220 V main EMLUS-1250 is suitable for 50 W power values that operate on 12 V.
power. It is manufactured for the lamps and luminaires with up to 30 W output power. It provides the same light as in operation on main power in the case of emergency.
It provides the same light as in operation on main power in the case of emergency.

13
EMERGENCY EXIT LUMINAIRES

EMERGENCY EXIT LUMINAIRES THE INSTALLATION OF THE EMERGENCY EXIT LUMINAIRES


For the people to reach the exits easily during emergencies, emergency exits luminaires should be installed in buildings. It
is compulsory to install emergency exit signs in order to show people in the building the locations of the exits to be used for The details on the installation of the emergency exit luminaires are explained in EN 50172 and EN 1838 standards.
evacuation and the planned exit routes from every point in the building in the case of an emergency.

These luminaires, which can be one-sided or double-sided, have graphic signs on them that provide orientation. The
luminaires can be installed on the wall, on the ceiling or on the suspended ceiling. They can also be hanged down by using
components such as hangers, chains and slings.

At all exits to be used in the All points that dictate Throughout the
case of an emergency a change in direction corridor

THE SIGN (PICTOGRAM) FORMATS OF THE EMERGENCY EXIT LUMINAIRES


It is very important that the escape route is marked clearly in order to provide a quick and safe evacuation in areas and
buildings. The effect of an exit sign depends on the size, the color, the position and the high visibility of the sign. The
European standards approve and support the use of pictograms that use white drawings on a green background.

OPERATION TYPES OF EMERGENCY EXIT LUMINAIRES The lighting level ratios of green and white colors with respect to each other are defined in EN 1838 standards. The color
rendering index of the lamp must be at least 40 for the safety sign colors to be perceived. On the escape route, apart from
Non-Maintained Model the exit signs, there must not be any illuminated signs or objects that may cause hesitation or confusion regarding the
The lamp does not provide light when the main power is at its normal value. In the case of a main power failure or a main escape direction.
power interruption, the lamp starts to provide light by means of the battery and the electronic circuit located inside the
luminaire.
• Minimum lighting intensity = 2cd/m²
Maintained Model • The lighting intensity ratio between the most
The lamp provides light when the mains voltage is at its normal value. In the case of a power failure or a power and the least illuminated parts of the areas
interruption, the lamp continues to provide light by means of the battery and the electronic circuit located inside the with the same color must not be greater that
luminaire. 10:1.
• The lighting intensity ratio between the white
and green area must not be less than 5:1 and
more than 15:1.
• The green background should constitute at
least 50% of the area of the sign.

15
EMERGENCY EXIT LUMINAIRES

THE MAXIMUM VIEWING DISTANCE OF THE EMERGENCY EXIT LUMINAIRES PICTOGRAM ALTERNATIVES FOR EMERGENCY EXIT LUMINAIRES
It is very important to assure that the signs that show the escape routes are visible from everywhere. For this purpose, The details regarding the icons that are used in the emergency exit luminaires are listed in the standards EN ISO 7010,
EN 1838 standard states that the maximum viewing distance should be determined in accordance with the height of the ISO 3864-1 and ISO 16069.
pictogram. The standard provides the formula below:

d=sxh

d: Maximum viewing distance


h: Pictogram’s height
s= 100, for signs illuminated from outside
s= 200, for signs illuminated from within

For example, for an emergency exit luminaire located at the end of a 20 meter corridor the height of the sign (pictogram)
must be at least 10 cm if it is illuminated from within and at least 20 cm if it is illuminated from outside.

h h

For the sings illuminated from For the sings illuminated from
within it has to be 200 times of the outside it has to be 100 times of the
height of the sign height of the sign

LIGHTING DURATION OF THE EMERGENCY EXIT LUMINAIRES


Emergency lighting must be provided for at least 60 minutes in the case of an interruption in the normal lighting. In the
buildings with a occupants load of 200 or more, emergency lighting must be provided for at least 120 minutes.

17
EMERGENCY LIGHTING LUMINAIRES

EMERGENCY LIGHTING SYSTEM ESCAPE ROUTE LIGHTING


Emergency lighting systems are the systems that become automatically active and provide adequate lighting when the The emergency lighting level has to be set at 1 lux at least at any point of the central line of the escape route. At the end
main power or a similar external electric supply is interrupted due to a breakdown, when the power in a building is cut for of the emergency operating period, the lighting level should not fall below the level of 0.5 lux at any point. The lighting
safety reasons in the case of a fire or an earthquake and when normal lighting is interrupted after a circuit breaker or a level ratio between the points with the highest and lowest lighting levels must not be more than 1/40. 50% of the required
fuse is switched on. level of the emergency lighting must be provided within 5 seconds and full capacity must be reached within 60 seconds.
Emergency lighting for the purpose of evacuation must be on at least for one hour.

Emergency Lighting

Emergency Escape Lighting Standby Lighting

Emergency Escape Lighting

Open Area Lighting


Emax Emin Emax

Highly Risky Task Area Emax: Emin ≤ 40 : 1 lx


Lighting

OPEN AREA (ANTI - PANIC) LIGHTING


Standby Lighting
Standby lighting is the emergency lighting type envisaged for the continuity of the current conditions and the operations According to EN 1838 and EN 60598-2-22 standards, areas and gathering points larger than 60m2 are classified as open
before the interruption of normal lighting. This lighting type is not included in emergency escape scenarios. areas. The magnitude of illumination above the floor level at open areas must be at least 0.5 lux. The edges and the area
surrounding the edges within 0.5 meter are not included in this scope. The ratio of the magnitude of illumination between
Emergency Escape Lighting the most and the least illuminated points in open areas must not be more than 40:1.
Emergency escape lighting is the emergency lighting that provides the necessary lighting for the safety of the people who
are evacuating a building or an area in the case of an emergency, or who are trying to finalize a potentially hazardous
action before evacuation. There are 3 types of emergency escape lighting. 0,5 m

A- Escape Route Lighting


Escape route lighting is the emergency lighting type that assists in the safe evacuation of the people from the building by
Minimum lighting level
illuminating the escape routes in the case of an emergency.
Emin = 0,5 lx

B- Open Area Lighting


Minimum-maximum lighting level ratio
Emax : Emin < 40 : 1 lx
Open area lighting is the lighting type envisaged for areas larger than 60m2 or for gathering points and it provides access
to the predetermined escape routes in the case of an emergency. It is also known as anti-panic lighting. Color rendering index
CRI 40
C- Highly Risky Task Area Lighting
Highly risky task area lighting is the lighting that is manufactured for the safety of the people who are located in areas Period specified for emergency escape
where possibly hazardous processes or conditions may occur in the case of emergency. In certain systems, it provides the 1 saat
users with opportunities for appropriate deactivation

19
EMERGENCY LIGHTING LUMINAIRES

HIGHLY RISKY TASK AREA LIGHTING OPERATING MODES OF EMERGENCY LIGHTING LUMINAIRES

Energy distribution, production and industrial process control rooms, engine-generator control rooms, locations that have Non-Maintained Mode
machines in motion, elevators and conveyors that do not immediately stop when the power is cut are classified as highly The lamp does not provide light when the main power is at its normal value. It starts providing light in the case of a main
risky and hazardous areas. Emergency lighting level in areas with a high risk of a dangerous situation must not be less power failure. The lamp is switched on by means of the battery inside the luminaire in the case of a failure.
than 10% of the normal lighting level.

Minimum lighting level


Emin = 15 lx

Minimum-maximum lighting level ratio


Emax : Emin < 10 : 1 lx

Color rendering index


CRI 40

Period specified for emergency escape


As long as the risk exists

EMERGENCY LIGHTING LUMINAIRES

Escape Route Lighting Luminaires


According to the standards, they must be installed at a height between 2 and 4.5 meters. They can be directly installed on the
walls, ceilings or mounted ceilings or they can be hung down by using components such as hangers, chains and slings.
Maintained mode
In this type of luminaires, the lamp provides light when the mains voltage is at its normal value. In the case of a main
powerfailure, it continues to provide light by means of the battery in the luminaire. In some versions, the lamp can be
switched off when desired by installing an external switch.

Open Area Lighting Luminaires


Open area emergency lighting luminaires have lamps with moving head. These lamps can be projected towards the desired
direction. They can be used in large areas such as factories and garages and in surroundings that require a high level of
lighting.

21
EMERGENCY LIGHTING LUMINAIRES

LOCATIONS WHERE THE USE OF AN EMERGENCY LIGHTING SYSTEM IS COMPULSORY

The use of emergency lighting is compulsory in the following locations

• All escape routes,


• Locations which are used for gathering,
• Elevators and escalators,
• Locations where ground level changes and the intersections of corridors,
• Workshops and laboratories where machinery in motion and chemicals that pose high risk are located,
• Electricity distribution and generator rooms,
• Central battery unit rooms,
• Gas stations,
• Indoors car parks,
• Areas where first aid and safety kits are located,
• Areas where fire alarm buttons and fire cabinets are located.

The use of emergency lighting is compulsory in the following buildings

• Hospitals, nursing homes and buildings for education,


• All buildings with a occupants load of 200 or more,
• Buildings with 50 or more occupants under the ground level,
• Buildings without windows,
• Hotels, motels and dormitories,
• Highly hazardous locations,
• Tall buildings.

23
BATTERY USER’S MANUAL

• Emergency lighting units must be operated on a non-switched phase with the voltage stated on them. Power must not
be interrupted except for maintenance and testing purposes. Continuously turning off and on the line which the device is
connected wears the fluorescent lamps and battery.

• Emergency lighting units must not be operated in environments where the temperature is not within the operating
environment temperature threshold stated on the unit for long periods. If they are, this may cause damage in the device
and the battery.

• Emergency lighting units must be operated in environments that comply with the IP Protection Class conditions that are
stated on the units. Operating the device in environments other than those stated may cause damage in the device and the
battery.

• The initial charging time of the battery is 48 hours for 1-hour capacity products and 96 hours for 3-hour capacity products.
For the next charges, 24 hours for 1-hour capacity products and 48 hours for 3-hour capacity products are enough for the
battery to be fully charged.

• When installing emergency lighting units, the battery must be connected to the emergency unit circuit when the
luminaire is to be used. In cases where it takes time for the luminaire to be operative after the installation, the battery
must be removed from its socket after the necessary controls.

• The emergency lighting units and emergency exit luminaires should not be stored inactive for too long since their
batteries are already mounted. Batteries that remain inactive in the socket for long periods before the actual energy supply
may irreversibly be damaged.

• A previously charged battery loses 15% of its capacity per month when it is not used. Thus, previously charged batteries
must not remain inactive for more than 3 months. Uncharged batteries can remain inactive for 2 years in favorable storage
conditions. It is not suggested to store the batteries under temperatures higher than 40°C.

• Batteries that remained inactive for a long time may require around two to ten charging cycles to reach full capacity.

• In emergency lighting unit installations, the unswitched line must be disconnected once in every six months and the
battery capacities must be tested. Before this test is conducted, it must be checked that there were no interruptions in the
line for 24 hours for 1-hour capacity products and 48 hours for 3-hour capacity products and that the battery is sufficiently
charged. Once this is checked, the power to the device must be cut and the “Emergency Lighting Duration” of the lamps
must be controlled. It must be confirmed by the operator conducting the test that the lamps provide light for duration time
that declerated by producer.
The operator must inform the authorities that the batteries of the luminaires that cannot deliver the required performance
have completed their life cycles.

• When the battery is to be changed, first the power to the device must be cut and then the old battery must be replaced
with an equivalent battery. When replacing the battery, the use of lower than required capacity batteries may cause the

BATTERY USER’S
device not to operate whereas the use of higher than required capacity batteries may cause the device to break down.

• Out of use batteries must not be thrown away with regular waste. They must be sent to waste collection centers or to the
manufacturer in order to be sent to these centers.

MANUAL
25
BATTERY DETAILS TABLE
(ALL PRODUCTS)

TECHNOLOGY BATTERY CAPACITY VOLTAGE MAXIMUM MINIMUM CHARGE CHARGE VOLTAGE MAXIMUM DISCHARGE MINIMUM DISCHARGE DISCHARGE TEMPERATURE USAGE
OF THE BATTERY DESIGNATION CHARGE CURRENT CURRENT LIMIT CURRENT CURRENT VOLTAGE LIMIT RATING INFORMATION

Discharge every 6 months.


1,2V 200mA 160mA 1.55V 2800mA - 1000mA - 1V Recommended
Ni-Cd D, KRMU 33/60 4000mAh Discharge 1000mA
per cell permanent charge permanent charge per cell for 1 h discharge for 3 h discharge per cell 0 - 55 °C
for 10 to 20 minutes.
Discharge every 6 months.
1,2V 150mA 120mA 1.55V 2100mA - 750mA - 1V Recommended
Ni-Cd C, KRMU 26/50 3000mAh Discharge 750mA
per cell permanent charge permanent charge per cell for 1 h discharge for 3 h discharge per cell 0 - 55 °C
for 10 to 20 minutes.
Discharge every 6 months.
1,2V 125mA 100mA 1.55V 1750mA 625mA - 1V Recommended
Ni-Cd C, KRMU 26/50 2500mAh Discharge 600mA
per cell permanent charge permanent charge per cell for 1 h discharge for 3 h discharge per cell 0 - 55 °C
for 10 to 20 minutes.
Discharge every 6 months.
1,2V 90mA 70mA 1.55V 1250mA - 450mA - 1V Recommended
Ni-Cd SC, KRMU 23/43 1800mAh Discharge 450mA
per cell permanent charge permanent charge per cell for 1 h discharge for 3 h discharge per cell 0 - 55 °C
for 10 to 20 minutes.
Discharge every 6 months.
1,2V 80mA 65mA 1.55V 1150mA - 400mA - 1V Recommended
Ni-Cd SC, KRMU 23/43 1600mAh Discharge 400mA
per cell permanent charge permanent charge per cell for 1 h discharge for 3 h discharge per cell 0 - 55 °C
for 10 to 20 minutes.
Discharge every 6 months.
1,2V 60mA 48mA 1.55V 840mA - 300mA - 1V Recommended
Ni-Cd SC, KRMU 23/43 1200mAh Discharge 250mA
per cell permanent charge permanent charge per cell for 1 h discharge for 3 h discharge per cell 0 - 55 °C
for 10 to 20 minutes.
Discharge every 6 months.
1,2V 45mA 35mA 1.55V 650mA - 220mA - 1V Recommended
Ni-Cd AA, KRMU 15/51 900mAh Discharge 220mA
per cell permanent charge permanent charge per cell for 1 h discharge for 3 h discharge per cell 0 - 55 °C
for 10 to 20 minutes.

27
WIRELESS
EMERGENCY LIGHTING
MONITORING SYSTEM
Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 29
WELCO- OVERVIEW

Regular system controls must be done in order to ensure that any emergency lighting system is in a completely working WELCO SOFTWARE GRAPHIC INTERFACE WORKING ON CLOUD
condition. Building managements must provide routine tests of emergency lighting , keep their records and show them to
the relevant authorities when necessary.
• Easy to control via single software
Emergency lighting monitoring systems monitor connected emergency lighting products and systems continuously, make • Remote testing with a single click
automated periodic tests and report. Thus, information about working condition of the products in emergency cases such • Ability to display and monitor areas on map
as earthquake, fire, etc. is sent to building management. • Ability to distinguish areas as buildings and floors
• Monitoring Emergency Lighting on floor plans
• Monitoring all areas and components in the same interface as a tree branch structure
• Displaying battery, test, lamp etc. conditions of emergency lighting with user friendly icons
• Defining timing of function and period tests and carrying out tests automatically on time
• Generating test reports with date and time stamps
• Taking detailed test reports as excel files

WIRELESS MONITORING SYSTEM-WELCO

Welco is our wireless system solution that allows you to monitor the status of our
emergency lighting products via the internet

Each emergency lighting includes a wireless communication module with Wi-Fi


technology that proved itself in wireless communication. It is enough just to connect
emergency lighting to 230V city mains.

• Wireless , Wi-Fi (802.11 b/g/n) and cloud based.


• It does not need extra cost and workmanship for cabling.
• It can be tested and reported from everywhere of the world on demanded time.
• Efficient use of resources is provided by evaluating the existing wi-fi substructure.
• Periodic function and duration tests of products are carried out on a routine basis.
• It is possible to provide test and teporting as services when needed.

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 31
WELCO- OVERVIEW

WHY CLOUD TECHNOLOGY?

With WELCO cloud monitoring system developed by Beş A, you can access many information such as failure status, test
history of your emergency lights, from anywhere you have internet connection by entering your user name and password
via a web browser with your computer, tablet or smartphone.
USER USER
• Test status and history of emergency lighting devices can be accessed over internet without physically visiting any panel.
• Products can be monitored and managed from a single point, even if they are at different geographical locations.
• Alerts, such as test fails, are automatically sent to the e-mail address you have defined.
• The real-time status of the products is monitored in groups or individually.
• Test reports can be downloaded in excel format, where products are easily filtered according to the failure types or
location based, and shared with the technical service.

Wi-Fi Wi-Fi
MODEM MODEM

CLOUD SERVER
bes-a-welco.com

CUSTOMER- SITE A CUSTOMER- SITE B

INTRANET

USER

CUSTOMER- SITE C

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 33
BATTERY AND MAINS DATA
EMERGENCY LIGHTING UNITS - LED PRODUCT
CODE
BATTERY
CAPACITY
RATED MAINS
POWER (W)* CURRENT (A)*
POWER
FACTOR (PF)*
DIMENSIONS
(mm)
WEIGHT
(kg)
QTY
in CARTON BOX
EMLUS-SLED / WELCO EMLUS-SLED/WELCO-2W/3H 3,6 V / 1800 mAh 2,40 0,021 0,48 42 x 234,5 x 23,5 0,130 50
EMLUS-SLED/WELCO-3W/1H 3,6 V / 1600 mAh 2,31 0,021 0,47 42 x 234,5 x 23,5 0,130 50
EMLUS-SLED/WELCO-3W/3H 3,6 V / 3000 mAh 2,96 0,024 0,52 42 x 234,5 x 23,5 0,130 50

Wireless communication, Wi-Fi (802.11 b/g/n) * Measured under 230 V mains.


Possible to access from anywhere in the world with cloud technology
Remote monitoring and testing with WELCO software
Compatible with panel LED, COB LED and power LED
EMERGENCY LUMEN FACTOR (2W)
Compatible with all dimmable and non-dimmable, LED OPERATING LED OPERATING LED OPERATING LED OPERATING LED OPERATING LED OPERATING
constant current LED control gears VOLTAGE CURRENT 350mA CURRENT 500mA CURRENT 700mA CURRENT 1050mA CURRENT 1400mA
Non-maintained operation 9 ... 30 VDC %16,50 %11,50 %8,00 %5,50 %4,00
Emergency lighting function by interruption of the unswitched phase 31 ... 50 VDC %10,00 %7,00 %5,00 %3,00 -
1 - 3 h duration 51 ... 70 VDC %7,00 %5,00 %3,50 - -
Electromagnetic Interference (EMI) filter
Emergency lighting function in case of low-voltage Measured with 3,6 V battery under maximum operating voltage.
Constant output power
Operation range of 9 ... 70 VDC, optional 200 VDC
Short-circuit, open-circuit and overload protection
High-temperature Ni-Cd battery cells EMERGENCY LUMEN FACTOR (3W)
Overcharge and deep discharge protection
LED OPERATING LED OPERATING LED OPERATING LED OPERATING LED OPERATING LED OPERATING
Polarity reversal protection for battery VOLTAGE CURRENT 350mA CURRENT 500mA CURRENT 700mA CURRENT 1050mA CURRENT 1400mA
Status display with two color LEDs
9 ... 30 VDC %26,00 %18,00 %13,00 %8,50 %6,50
Optional - Test switch
31 ... 50 VDC %15,50 %11,00 %7,50 %5,00 -
Optional - 110 VAC compatibility
51 ... 70 VDC %11,00 %7,50 %5,50 - -
Polycarbonate case
Simple connectable terminal block Measured with 3,6 V battery under maximum operating voltage.
Optional - LiFePO4 or Ni-MH battery application

BATTERY DATA
TÜVRheinland
VOLTAGE CAPACITY CELL TYPE CELL SIZE (mm) QTY OF CELLS DIMENSIONS (mm) WEIGHT (kg)

230 VAC GW FR4 EN EN EN


SELV 50/60 Hz IP 20 850°C PCB SMD 61347-2-7 61347-2-13 62034 3,6V 1600mAh SC 23 3 23 x 129±3 x 23 0,150
3,6V 1800mAh SC 23 3 23 x 129±3 x 23 0,150
In accordance with EN 61347-1, EN 61347-2-7, EN 62034 standards. 3,6V 3000mAh C 26 3 26 x 150±3 x 26 0,240

TECHNICAL DATA Battery dimensions are given without holder. When the holders are added, the length will increase by +40mm and the diameter +5mm.
Please refer to “Battery Details Table” in “Emergency Lighting Solutions Overview” section of the catalogue for further battery information.
SUPPLY VOLTAGE : 230 VAC 50/60 Hz OUTPUT CURRENT : 25 … 300 mA
AMBIENT TEMPERATURE (ta) : -10 °C … +50 °C OUTPUT VOLTAGE : 9 ... 70 VDC
MAX. CASING TEMPERATURE (tc) : 70 °C OPEN CIRCUIT VOLTAGE : 70 VDC
RATED DURATION : 1/3h PROTECTION CLASS : IP 20
BATTERY CHARGING TIME : 24 h INSULATION CLASS : II
EMERGENCY LUMEN FACTOR (BLF) : %4 ... %26 WIRING DIAGRAM TECHNICAL DRAWING

PRODUCT LIST
PRODUCT OUTPUT LED MODULE OUTPUT LED CURRENT SERIES LED OUTPUT
CODE CURRENT* VOLTAGE RANGE TOLERANCE QUANTITY POWER*
EMLUS-SLED/WELCO-2W/3H 25 … 190 mA 9 ... 70 VDC ±%5 3 ... 23 LED 1,75 W
EMLUS-SLED/WELCO-3W/1H 40 … 300 mA 9 ... 70 VDC ±%5 3 ... 23 LED 2,75 W
EMLUS-SLED/WELCO-3W/3H 40 … 300 mA 9 ... 70 VDC ±%5 3 ... 23 LED 2,75 W

* Measured using maximum LED quantities with 3,6 V battery.

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 35
PRODUCT LIST
EMERGENCY EXIT LUMINAIRES - LED PRODUCT
CODE
RATED
DURATION
OPERATING
MODE*
LIGHT
SOURCE
ROUTING
MODE
TYPE OF
MOUNTING
TUNA L / WELCO BYAL-L08/WELCO-CY/SU 3h Maintained 12 x SMD LED Double-sided Surface Mounted - Plastic Hanger
BYAL-L08/WELCO-CY/SUMA 3h Maintained 12 x SMD LED Double-sided Surface Mounted - Steel Wire
BYAL-L08/WELCO-CY/MT 3h Maintained 12 x SMD LED Double-sided Surface Mounted - Metal Hanger
BYAL-L08/WELCO-CY/SA 3h Maintained 12 x SMD LED Double-sided Recessed Mounted
Wireless communication, Wi-Fi (802.11 b/g/n)
Possible to access from anywhere in the world with cloud technology * Maintained: Lights on mains and stays alight in case of the mains failure.
Remote monitoring and testing with WELCO software
Single- or double-sided
Anodized aluminum case
Polycarbonate side cover and hanger MAINS DATA
SMD LED application
PRODUCT RATED MAINS POWER DIMENSIONS WEIGHT QTY
Status display with green and red LEDs CODE POWER (W)* CURRENT (A)* FACTOR (PF)* (mm) (kg) in CARTON BOX
Test switch
High-temperature Ni-Cd battery cells BYAL-L08/WELCO-CY/SU 4,82 0,032 0,63 40 x 304 x 235 0,700 1
BYAL-L08/WELCO-CY/SUMA 4,82 0,032 0,63 40 x 304 x 235 0,700 1
Overcharge and deep discharge protection
BYAL-L08/WELCO-CY/MT 4,82 0,032 0,63 40 x 304 x 235 0,700 1
Transparent Plexiglas with screen printed
BYAL-L08/WELCO-CY/SA 4,82 0,032 0,63 102 x 372 x 235 1,255 1
Side lighting
Ceiling mounted, ceiling recessed or wall mounted
* Measured under 230 V mains.
Optional - 110 VAC compatibility
Optional - Metal hanger, hook or steel wire
Optional - LiFePO4 or Ni-MH battery application

RECESSED MOUNTING HOLE SIZE WIRING DIAGRAM

Please refer to “Pictogram Table” in Emergency Exit Luminaries Overview section of the catalogue for alternatives.

230 VAC 41 GW FR4 -IıIı- EN EN


SELV 50/60 Hz IP 20 ALU 850°C PCB SMD Ni - Cd 60598-2-22 62034

In accordance with EN 60598-1, EN 60598-2-22, EN 62034 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz SIGN DIMENSIONS : 180 x 299 mm
AMBIENT TEMPERATURE (ta) : 0 °C … +40 °C VIEWING DISTANCE : 36 m
RATED DURATION : 3h PROTECTION CLASS : IP 20
BATTERY CHARGING TIME : INSULATION CLASS :
24 h I TECHNICAL DRAWING / SURFACE MOUNTED TECHNICAL DRAWING / RECESSED MOUNTED
BATTERY TYPE : 3,6 V Ni-Cd

LED INDICATION FUNCTIONS


Permanent GREEN Charge mode
Fast flashing GREEN (0,1s on - 0,1s off) Function test
Slow flashing GREEN (1s on - 1s off) Duration test
Permanent RED Load failure
Slow flashing RED (1s on - 1s off) Battery failure
Fast flashing RED (0,1s on - 0,1s off) Charging failure
Double pulsing GREEN Inhibit mode
Binary transmission of address via GREEN/RED Addressing or identification
GREEN and RED off Emergency mode

TEST SWITCH FUNCTIONS


Short press (<1s) Starts the function test or terminate the all tests.
Long press (>5s)* Starts the duration test.
* The battery must be 100% full before the duration test can be started.
Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 37
PRODUCT LIST
EMERGENCY EXIT LUMINAIRES - LED
LAPİN LED / WELCO PRODUCT
CODE
RATED
DURATION
OPERATING
MODE*
LIGHT
SOURCE
ROUTING
MODE
TYPE OF
MOUNTING
LİPSOS LED / WELCO BYAL06-S/LED/WELCO 3h Maintained 12 x SMD LED Double-sided (Lapin) Surface Mounted - Plastic Hanger
BYAL06-S/LED/WELCO/SA 3h Maintained 12 x SMD LED Double-sided (Lapin) Recessed Mounted
BYAL07-S/LED/WELCO 3h Maintained 12 x SMD LED Single-sided (Lipsos) Surface Mounted - Plastic Hanger
BYAL07-S/LED/WELCO/SA 3h Maintained 12 x SMD LED Single-sided (Lipsos) Recessed Mounted
Wireless communication, Wi-Fi (802.11 b/g/n)
Possible to access from anywhere in the world with cloud technology * Maintained: Lights on mains and stays alight in case of the mains failure.
Remote monitoring and testing with WELCO software
Single- or double-sided
Anodized aluminum case
Polycarbonate side cover and hanger MAINS DATA
SMD LED application
PRODUCT RATED MAINS POWER DIMENSIONS WEIGHT QTY
Status display with green and red LEDs CODE POWER (W)* CURRENT (A)* FACTOR (PF)* (mm) (kg) in CARTON BOX
Test switch
High-temperature Ni-Cd battery cells BYAL06-S/LED/WELCO 5,2 0,036 0,63 365 x 43 x 198 0,825 1
BYAL06-S/LED/WELCO/SA 5,2 0,036 0,63 425 x 43 x 216 0,955 1
Overcharge and deep discharge protection
BYAL07-S/LED/WELCO 5,2 0,036 0,63 365 x 43 x 198 0,970 1
White acrylic plate
BYAL07-S/LED/WELCO/SA 5,2 0,036 0,63 425 x 43 x 216 1,100 1
Back lighting
Ceiling mounted, ceiling recessed or wall mounted
* Measured under 230 V mains.
Optional - 110 VAC compatibility
Optional - Metal hanger, hook or steel wire
Optional - LiFePO4 or Ni-MH battery application

WIRING DIAGRAM

Please refer to “Pictogram Table” in Emergency Exit Luminaries Overview section of the catalogue for alternatives.

230 VAC 41 GW FR4 -IıIı- EN EN


SELV 50/60 Hz IP 20 ALU 850°C PCB SMD Ni - Cd 60598-2-22 62034

In accordance with EN 60598-1, EN 60598-2-22, EN 62034 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz SIGN DIMENSIONS : 170 x 335 mm
AMBIENT TEMPERATURE (ta) : 0 °C … +40 °C VIEWING DISTANCE : 34 m
RATED DURATION : 3h PROTECTION CLASS : IP 20
BATTERY CHARGING TIME : INSULATION CLASS :
24 h I TECHNICAL DRAWING / SURFACE MOUNTED TECHNICAL DRAWING / RECESSED MOUNTED
BATTERY TYPE : 3,6 V Ni-Cd

LED INDICATION FUNCTIONS


Permanent GREEN Charge mode
Fast flashing GREEN (0,1s on - 0,1s off) Function test
Slow flashing GREEN (1s on - 1s off) Duration test
Permanent RED Load failure
Slow flashing RED (1s on - 1s off) Battery failure
Fast flashing RED (0,1s on - 0,1s off) Charging failure
Double pulsing GREEN Inhibit mode
Binary transmission of address via GREEN/RED Addressing or identification
GREEN and RED off Emergency mode

TEST SWITCH FUNCTIONS


Short press (<1s) Starts the function test or terminate the all tests.
Long press (>5s)* Starts the duration test.
* The battery must be 100% full before the duration test can be started.
Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 39
PRODUCT LIST
EMERGENCY EXIT LUMINAIRES - LED
LAPİN XL LED / WELCO PRODUCT
CODE
RATED
DURATION
OPERATING
MODE*
LIGHT
SOURCE
ROUTING
MODE
TYPE OF
MOUNTING
LİPSOS XL LED / WELCO BYAL-XL06-LED/WELCO-S 3h Maintained 24 X SMD LED Double-sided (Lapin) Surface Mounted - Hook Hanger
BYAL-XL07-LED/WELCO-S 3h Maintained 24 X SMD LED Single-sided (Lipsos) Wall Mounted

* Maintained: Lights on mains and stays alight in case of the mains failure.
Wireless communication, Wi-Fi (802.11 b/g/n)
Possible to access from anywhere in the world with cloud technology
Remote monitoring and testing with WELCO software
Single- or double-sided
Anodized aluminum case
Polycarbonate side cover and hanger
SMD LED application
MAINS DATA
Status display with green and red LEDs PRODUCT RATED MAINS POWER DIMENSIONS WEIGHT QTY
Test switch CODE POWER (W)* CURRENT (A)* FACTOR (PF)* (mm) (kg) in CARTON BOX
High-temperature Ni-Cd battery cells
BYAL-XL06-LED/WELCO-S 6,4 0,044 0,63 630 x 43 x 430 2,400 1
Overcharge and deep discharge protection
BYAL-XL07-LED/WELCO-S 6,4 0,044 0,63 630 x 43 x 430 2,400 1
White acrylic plate
Back lighting
* Measured under 230 V mains.
Ceiling mounted, ceiling recessed or wall mounted
Optional - 110 VAC compatibility
Optional - Metal hanger, hook or steel wire
Optional - LiFePO4 or Ni-MH battery application

Please refer to “Pictogram Table” in Emergency Exit Luminaries Overview section of the catalogue for alternatives. WIRING DIAGRAM TECHNICAL DRAWING

230 VAC 41 GW FR4 -IıIı- EN EN


SELV 50/60 Hz IP 20 ALU 850°C PCB SMD Ni - Cd 60598-2-22 62034

In accordance with EN 60598-1, EN 60598-2-22, EN 62034 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz SIGN DIMENSIONS : 400 x 600 mm
AMBIENT TEMPERATURE (ta) : 0 °C … +40 °C VIEWING DISTANCE : 80 m
RATED DURATION : 3h PROTECTION CLASS : IP 20
BATTERY CHARGING TIME : 24 h INSULATION CLASS : I
BATTERY TYPE : 3,6 V Ni-Cd

LED INDICATION FUNCTIONS


Permanent GREEN Charge mode
Fast flashing GREEN (0,1s on - 0,1s off) Function test
Slow flashing GREEN (1s on - 1s off) Duration test
Permanent RED Load failure
Slow flashing RED (1s on - 1s off) Battery failure
Fast flashing RED (0,1s on - 0,1s off) Charging failure
Double pulsing GREEN Inhibit mode
Binary transmission of address via GREEN/RED Addressing or identification
GREEN and RED off Emergency mode

TEST SWITCH FUNCTIONS


Short press (<1s) Starts the function test or terminate the all tests.
Long press (>5s)* Starts the duration test.
* The battery must be 100% full before the duration test can be started.
Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 41
PRODUCT LIST
EMERGENCY EXIT LUMINAIRES - LED PRODUCT
CODE
RATED
DURATION
OPERATING
MODE*
LIGHT
SOURCE
ROUTING
MODE
TYPE OF
MOUNTING
ORFOZ / WELCO BYPL02-S-XLED2/WELCO 3h Main- 20 x SMD LED Double-sided Surface Mounted
tained
* Maintained: Lights on mains and stays alight in case of the mains failure.

Wireless communication, Wi-Fi (802.11 b/g/n)


Possible to access from anywhere in the world with cloud technology
Remote monitoring and testing with WELCO software
Indoor and outdoor use
Polycarbonate case and glass
Moisture-proof
SMD LED application
MAINS DATA
High energy saving PRODUCT RATED MAINS POWER DIMENSIONS WEIGHT QTY
Long life-time (50.000 hours) CODE POWER (W)* CURRENT (A)* FACTOR (PF)* (mm) (kg) in CARTON BOX
Emergency lighting function by interruption of the unswitched phase
BYPL02-S-XLED2/WELCO 5,0 0,036 0,60 122 x 360 x 205 1,025 1
Emergency lighting function in case of low-voltage
3 hours duration in case of emergency
* Measured under 230 V mains.
Status display with green and red LEDs
Test switch
High-temperature Ni-Cd battery cells
Overcharge and deep discharge protection
Ceiling mounted
Optional - 110 VAC compatibility
Optional - LiFePO4 or Ni-MH battery application

Please refer to “Pictogram Table” in Emergency Exit Luminaries Overview section of the catalogue for alternatives. WIRING DIAGRAM TECHNICAL DRAWING

230 VAC GW FR4 -IıIı- EN EN


SELV 50/60 Hz IP 65 850°C PCB SMD Ni - Cd 60598-2-22 62034

In accordance with EN 60598-1, EN 60598-2-22, EN 62034 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz SIGN DIMENSIONS : 140 x 300 mm
AMBIENT TEMPERATURE (ta) : -5 °C … +40 °C VIEWING DISTANCE : 28 m
RATED DURATION : 3h PROTECTION CLASS : IP 65
BATTERY CHARGING TIME : 24 h INSULATION CLASS : II
BATTERY TYPE : 3,6 V Ni-Cd

LED INDICATION FUNCTIONS


Permanent GREEN Charge mode
Fast flashing GREEN (0,1s on - 0,1s off) Function test
Slow flashing GREEN (1s on - 1s off) Duration test
Permanent RED Load failure
Slow flashing RED (1s on - 1s off) Battery failure
Fast flashing RED (0,1s on - 0,1s off) Charging failure
Double pulsing GREEN Inhibit mode
Binary transmission of address via GREEN/RED Addressing or identification
GREEN and RED off Emergency mode

TEST SWITCH FUNCTIONS


Short press (<1s) Starts the function test or terminate the all tests.
Long press (>5s)* Starts the duration test.
* The battery must be 100% full before the duration test can be started.
Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 43
PRODUCT LIST
EMERGENCY EXIT LUMINAIRES - LED PRODUCT
CODE
RATED
DURATION
OPERATING
MODE*
LIGHT
SOURCE
ROUTING
MODE
TYPE OF
MOUNTING
SOMON XLED2 / WELCO BYPL06-S-XLED2/WELCO 3h Maintained 20 x SMD LED Single-sided Surface Mounted

* Maintained: Lights on mains and stays alight in case of the mains failure.

Wireless communication, Wi-Fi (802.11 b/g/n)


Possible to access from anywhere in the world with cloud technology
Remote monitoring and testing with WELCO software
Indoor and outdoor use
Polycarbonate case and glass
Moisture-proof
SMD LED application
MAINS DATA
High energy saving PRODUCT RATED MAINS POWER DIMENSIONS WEIGHT QTY
Long life-time (50.000 hours) CODE POWER (W)* CURRENT (A)* FACTOR (PF)* (mm) (kg) in CARTON BOX
Emergency lighting function by interruption of the unswitched phase
BYPL06-S-XLED2/WELCO 5,05 0,036 0,60 108 x 341 x 60 0,630 1
Emergency lighting function in case of low-voltage
3 hours duration in case of emergency
* Measured under 230 V mains.
Status display with green and red LEDs
Test switch
High-temperature Ni-Cd battery cells
Overcharge and deep discharge protection
Wall mounted
Optional - 110 VAC compatibility
Optional - LiFePO4 or Ni-MH battery application

Please refer to “Pictogram Table” in Emergency Exit Luminaries Overview section of the catalogue for alternatives. WIRING DIAGRAM TECHNICAL DRAWING

230 VAC GW FR4 -IıIı- EN EN


SELV 50/60 Hz IP 65 850°C PCB SMD Ni - Cd 60598-2-22 62034

In accordance with EN 60598-1, EN 60598-2-22, EN 62034 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz SIGN DIMENSIONS : 108 x 341 mm
AMBIENT TEMPERATURE (ta) : -5 °C … +40 °C VIEWING DISTANCE : 21 m
RATED DURATION : 3h PROTECTION CLASS : IP 65
BATTERY CHARGING TIME : 24 h INSULATION CLASS : II
BATTERY TYPE : 3,6 V Ni-Cd

LED INDICATION FUNCTIONS


Permanent GREEN Charge mode
Fast flashing GREEN (0,1s on - 0,1s off) Function test
Slow flashing GREEN (1s on - 1s off) Duration test
Permanent RED Load failure
Slow flashing RED (1s on - 1s off) Battery failure
Fast flashing RED (0,1s on - 0,1s off) Charging failure
Double pulsing GREEN Inhibit mode
Binary transmission of address via GREEN/RED Addressing or identification
GREEN and RED off Emergency mode

TEST SWITCH FUNCTIONS


Short press (<1s) Starts the function test or terminate the all tests.
Long press (>5s)* Starts the duration test.
* The battery must be 100% full before the duration test can be started.
Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 45
EMERGENCY LIGHTING PRODUCT LIST
LUMINAIRES – LED PRODUCT
CODE
RATED
DURATION
OPERATING
MODE*
LIGHT
SOURCE
LIGHT INTENSITY on
ENERGY/EMERGENCY
TYPE of
MOUNTING
BATTERY
CHARGING TIME
RINA / WELCO AA104-RINA/WELCO/1W 3h Non-Maintained Power LED - / 105 lm Recessed / Surface Mounted 24 h
AA104-RINA/WELCO/2W 3h Non-Maintained Power LED - / 205 lm Recessed / Surface Mounted 24 h
AA104-RINA/WELCO/3W 3h Non-Maintained Power LED - / 305 lm Recessed / Surface Mounted 24 h
AA104-RINA/WELCO/4W 3h Non-Maintained Power LED - / 405 lm Recessed / Surface Mounted 24 h
Wireless communication, Wi-Fi (802.11 b/g/n)
Possible to access from anywhere in the world with cloud technology * Non-maintained : Lights in case of the mains failure.
Remote monitoring and testing with WELCO software
SMD power LED application
Long life-time (50.000 hours)
Emergency lighting function by interruption of the unswitched phase MAINS DATA
Emergency lighting function in case of low-voltage
3 hours duration in case of emergency PRODUCT BATTERY RATED MAINS POWER DIMENSIONS WEIGHT QTY
Status display with green and red LEDs CODE CAPACITY POWER (W) * CURRENT (A) * FACTOR (PF)* (mm) (kg) in CARTON BOX
Test switch
AA104-RINA/WELCO/1W 3,6V / 900mAh 1,45 0,018 0,35 Spot: 100 x 100 x 25 0,065 1
High-temperature Ni-Cd battery cells
Unit: 41 x 169,5 x 31,5 0,080
Overcharge and deep discharge protection
Battery: 39 x 221 x 34 0,100
Polycarbonate case
AA104-RINA/WELCO/2W 3,6V / 1800mAh 1,65 0,019 0,37 Spot: 100 x 100 x 25 0,065 1
Recessed mounted
Unit: 41 x 169,5 x 31,5 0,080
Asymmetric lens
Battery: 39 x 221 x 34 0,165
Optional - Symmetric lens application
AA104-RINA/WELCO/3W 3,6V / 3000mAh 2,60 0,024 0,45 Spot: 100 x 100 x 25 0,065 1
Optional - Surface mounted application
Unit: 41 x 169,5 x 31,5 0,080
Optional - LiFePO4 or Ni-MH battery application
Battery: 39 x 221 x 34 0,255
AA104-RINA/WELCO/4W 3,6V / 4000mAh 3,15 0,027 0,48 Spot: 100 x 100 x 25 0,065 1
Unit: 41 x 169,5 x 31,5 0,080
Battery: 39 x 221 x 34 0,390
* Measured under 230 V mains.

LED SPOT

FR4
BATTERY DATA
230 VAC GW -IıIı- EN EN
SELV 50/60 Hz IP 20 850°C CEM3 SMD Ni - Cd 60598-2-22 62034
PCB VOLTAGE CAPACITY CELL TYPE CELL SIZE (mm) QTY OF CELLS DIMENSIONS (mm) WEIGHT
(kg)
In accordance with EN 60598-1, EN 60598-2-22, EN 62034 standards. 3,6V 900mAh AA 15 3 15 x 153±3 x 15 0,085
3,6V 1800mAh SC 23 3 23 x 129±3 x 23 0,150
TECHNICAL DATA 3,6V 3000mAh C 26 3 26 x 150±3 x 26 0,240
3,6V 4000mAh D 33 3 33 x 180±3 x 33 0,375
SUPPLY VOLTAGE : 230 VAC 50/60 Hz LIGHT SOURCE : Power LED
AMBIENT TEMPERATURE (ta) : 0 °C … +40 °C DIFFUSER : Symmetric / Asymmetric LENS
RATED DURATION : 3h PROTECTION CLASS : IP 20
BATTERY CHARGING TIME : 24 h INSULATION CLASS : II
BATTERY TYPE : 3,6 V Ni-Cd

LED INDICATION FUNCTIONS WIRING DIAGRAM RECESSED MOUNTING HOLE SIZE


Permanent GREEN Charge mode
Fast flashing GREEN (0,1s on - 0,1s off) Function test
Slow flashing GREEN (1s on - 1s off) Duration test
Permanent RED Load failure
Slow flashing RED (1s on - 1s off) Battery failure
Fast flashing RED (0,1s on - 0,1s off) Charging failure
Double pulsing GREEN Inhibit mode
Binary transmission of address via GREEN/RED Addressing or identification
GREEN and RED off Emergency mode

TEST SWITCH FUNCTIONS


Short press (<1s) Starts the function test or terminate the all tests.
Long press (>5s)* Starts the duration test.
* The battery must be 100% full before the duration test can be started.
Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 47
EMERGENCY LIGHTING PHOTOMETRY DATA (3W)
LUMINAIRES – LED Open Area (Anti-Panic) Lighting (for min. 0,5 lux)
(Symmetric Lens)
Escape Route Lighting (for min. 1 lux)
(Asymmetric Lens)

RINA / WELCO
Mounting Distance Between Distance Between Mounting Distance Between Distance Between
Height (m) Luminaire and Wall (m) Luminaires (m) Height (m) Luminaire and Wall (m) Luminaires (m)
TECHNICAL DRAWING (LED SPOT) TECHNICAL DRAWING (EMERGENCY UNIT) 2,00 3,00 5,50 2,00 6,50 11,50
2,50 4,00 7,50 2,50 8,00 15,50
3,00 4,50 8,50 3,00 9,50 18,50
3,50 4,50 10,00 3,50 10,50 21,50
4,00 5,00 11,00 4,00 11,00 24,00

LIGHT DISTRIBUTION CURVE (SYMMETRIC LENS)

TECHNICAL DRAWING (BATTERY BOX)

LIGHT DISTRIBUTION CURVE (ASYMMETRIC LENS)

PHOTOMETRY DATA (1W)


Open Area (Anti-Panic) Lighting (for min. 0,5 lux) Escape Route Lighting (for min. 1 lux)
(Symmetric Lens) (Asymmetric Lens)

Mounting Distance Between Distance Between Mounting Distance Between Distance Between
Height (m) Luminaire and Wall (m) Luminaires (m) Height (m) Luminaire and Wall (m) Luminaires (m)
2,00 2,00 4,00 2,00 5,50 10,50
2,50 2,50 5,00 2,50 7,00 13,50
3,00 2,50 5,00 3,00 6,50 16,00
3,50 3,00 6,00 3,50 6,00 16,50
4,00 3,00 6,50 4,00 3,50 11,50

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 49
EMERGENCY LIGHTING PRODUCT LIST
LUMINAIRES – LED PRODUCT
CODE
RATED
DURATION
OPERATING
MODE*
LIGHT
SOURCE
LIGHT INTENSITY on
ENERGY/EMERGENCY
TYPE of
MOUNTING
BATTERY
CHARGING TIME
SOMON XLED2 / WELCO BYPL06-S-XLED2/WELCO/1W 3h Maintained 20 x SMD LED 115 lm / 115 lm Recessed / Surface Mounted 24 h
BYPL06-A-XLED2/WELCO/1W 3h Non-Maintained 20 x SMD LED - / 115 lm Recessed / Surface Mounted 24 h
BYPL06-A-XLED2/WELCO/2W 3h Non-Maintained 20 x SMD LED - / 230 lm Recessed / Surface Mounted 24 h
BYPL06-A-XLED2/WELCO/3W 3h Non-Maintained 20 x SMD LED - / 350 lm Recessed / Surface Mounted 24 h
Wireless communication, Wi-Fi (802.11 b/g/n) BYPL06-A-XLED2/WELCO/4W 3h Non-Maintained 20 x SMD LED - / 450 lm Recessed / Surface Mounted 24 h
Possible to access from anywhere in the world with cloud technology
Remote monitoring and testing with WELCO software * Non-maintained : Lights in case of the mains failure.
Indoor and outdoor use
Polycarbonate case and glass
Moisture-proof
SMD LED application
MAINS DATA
High energy saving PRODUCT RATED MAINS POWER DIMENSIONS WEIGHT QTY
Long life-time (50.000 hours) CODE POWER (W)* CURRENT (A)* FACTOR (PF)* (mm) (kg) in CARTON BOX
Emergency lighting function by interruption of the unswitched phase
BYPL06-S-XLED2/WELCO/1W 5,05 0,036 0,60 108x341x60 0,630 1
Emergency lighting function in case of low-voltage
BYPL06-A-XLED2/WELCO/1W 1,45 0,018 0,35 108x341x60 0,630 1
3 hours duration in case of emergency
BYPL06-A-XLED2/WELCO/2W 1,65 0,019 0,37 108x341x60 0,690 1
Status display with green and red LEDs BYPL06-A-XLED2/WELCO/3W 2,60 0,024 0,45 108x341x60 0,780 1
Test switch BYPL06-A-XLED2/WELCO/4W 3,15 0,027 0,48 108x341x60 0,850 1
High-temperature Ni-Cd battery cells
Overcharge and deep discharge protection * Measured under 230 V mains.
Ceiling mounted, ceiling recessed or wall mounted
Optional - 110 VAC compatibility
Optional - LiFePO4 or Ni-MH battery application

WIRING DIAGRAM RECESSED MOUNTING HOLE SIZE

230 VAC GW FR4 -IıIı- EN EN


SELV 50/60 Hz IP 65 SMD Ni - Cd 60598-2-22 62334
850°C PCB

In accordance with EN 60598-1, EN 60598-2-22, EN 62034 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz LIGHT SOURCE : SMD LED
AMBIENT TEMPERATURE (ta) : -5 °C … +40 °C DIFFUSER : Polycarbonate Glass
RATED DURATION : 3h PROTECTION CLASS : IP 65
BATTERY CHARGING TIME : INSULATION CLASS :
BATTERY TYPE :
24 h
3,6 V Ni-Cd
II
TECHNICAL DRAWING / RECESSED MOUNTED

LED INDICATION FUNCTIONS


Permanent GREEN Charge mode
Fast flashing GREEN (0,1s on - 0,1s off) Function test
Slow flashing GREEN (1s on - 1s off) Duration test
Permanent RED Load failure
Slow flashing RED (1s on - 1s off) Battery failure
Fast flashing RED (0,1s on - 0,1s off) Charging failure
Double pulsing GREEN Inhibit mode
Binary transmission of address via GREEN/RED Addressing or identification
GREEN and RED off Emergency mode

TEST SWITCH FUNCTIONS


Short press (<1s) Starts the function test or terminate the all tests.
Long press (>5s)* Starts the duration test.
* The battery must be 100% full before the duration test can be started.
Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 51
EMERGENCY LIGHTING PHOTOMETRY DATA (3W)
LUMINAIRES – LED
Open Area (Anti-Panic) Lighting Escape Route Lighting
(for min. 0,5 lux) (for min. 1 lux)

SOMON XLED2 / WELCO


Mounting Distance Between Distance Between Mounting Distance Between Distance Between
Height (m) Luminaire and Wall (m) Luminaires (m) Height (m) Luminaire and Wall (m) Luminaires (m)
TECHNICAL DRAWING / SURFACE MOUNTED 2,00 3,00 5,50 2,00 3,00 5,75
2,50 3,50 6,75 2,50 3,50 7,00
3,00 4,00 7,75 3,00 4,00 7,75
3,50 4,25 8,50 3,50 4,25 8,50
4,00 4,50 9,25 4,00 4,25 9,25

LIGHT DISTRIBUTION CURVE

PHOTOMETRY DATA (1W)


Open Area (Anti-Panic) Lighting Escape Route Lighting
(for min. 0,5 lux) (for min. 1 lux)

Mounting Distance Between Distance Between Mounting Distance Between Distance Between
Height (m) Luminaire and Wall (m) Luminaires (m) Height (m) Luminaire and Wall (m) Luminaires (m)
2,00 2,00 3,00 2,00 2,00 3,50
2,50 2,25 4,00 2,50 2,25 4,25
3,00 2,75 4,75 3,00 2,50 4,50
3,50 2,75 5,50 3,50 2,50 5,00
4,00 2,75 6,00 4,00 2,25 5,25

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 53
EMERGENCY LIGHTING PRODUCT LIST
LUMINAIRES – LED PRODUCT
CODE
RATED
DURATION
OPERATING
MODE*
LIGHT
SOURCE
LIGHT INTENSITY on
ENERGY/EMERGENCY
TYPE of
MOUNTING
BATTERY
CHARGING TIME
TETRA PW3 / WELCO AA209-PW3/WELCO 3h Non-Maintained 2x9W LED - / 1500 lm Surface Mounted 48 h

* Non-maintained : Lights in case of the mains failure.

Wireless communication, Wi-Fi (802.11 b/g/n)


Possible to access from anywhere in the world with cloud technology
MAINS DATA
Remote monitoring and testing with WELCO software PRODUCT RATED MAINS POWER DIMENSIONS WEIGHT QTY
180° adjustable LED headlamp CODE POWER (W)* CURRENT (A)* FACTOR (PF)* (mm) (kg) in CARTON BOX
SMD power LED application AA209-PW3/WELCO 1,25 - 8,90 0,010 - 0,058 0,50 - 0,67 98 x 255 x 205 4,50 1
Long life-time (30.000 hours)
Emergency lighting function by interruption of the unswitched phase * Measured under 230 V mains.
Emergency lighting function in case of low-voltage Maximum values are measured with discharged batteries and values are minimum measured with full-charged batteries.
3 hours duration in case of emergency
Status display with green and red LEDs
Test switch
Maintenance-free sealed lead acid battery TECHNICAL DRAWING WIRING DIAGRAM
Overcharge and deep discharge protection
Charging circuit with constant voltage and current protect
Wall mounted
ABS case
Optional - 110 VAC compatibility
Optional - LiFePO4 or Ni-MH battery application

LED SPOT

230 VAC FR4 -IıIı- EN EN


SELV 50/60 Hz IP 65 SMD Lead-Acid 60598-2-22 62034
PCB

In accordance with EN 60598-1, EN 60598-2-22, EN 62034 standards.


LIGHT DISTRIBUTION CURVE

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz HEADLAMP TYPE : 9W LED
AMBIENT TEMPERATURE (ta) : -5 °C … +40 °C CASE MATERIAL : ABS
RATED DURATION : 3h PROTECTION CLASS : IP 65
BATTERY TYPE : 12V Lead-Acid INSULATION CLASS : II

LED INDICATION FUNCTIONS


Permanent GREEN Charge mode
Fast flashing GREEN (0,1s on - 0,1s off) Function test
Slow flashing GREEN (1s on - 1s off) Duration test
Permanent RED Load failure
Slow flashing RED (1s on - 1s off) Battery failure
Fast flashing RED (0,1s on - 0,1s off) Charging failure
Double pulsing GREEN Inhibit mode
Binary transmission of address via GREEN/RED Addressing or identification
GREEN and RED off Emergency mode

TEST SWITCH FUNCTIONS


Short press (<1s) Starts the function test or terminate the all tests.
Long press (>5s)* Starts the duration test. * Above curve is measured data just for one headlamp
* The battery must be 100% full before the duration test can be started.
Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 55
EMERGENCY LIGHTING LUMINAIRES PRODUCT LIST
SENSORLIGHT - LED PRODUCT
CODE*
RATED
DURATION
OPERATING
MODE**
LIGHT
SOURCE
LIGHT INTENSITY on
ENERGY/EMERGENCY
TYPE OF
MOUNTING
BATTERY
CHARGING TIME
MANTA LED / WELCO AA105-MANTA-L6D/350/W3 3h Maintained 16 W / 3 W LED 1750 lm / 250 lm Surface Mounted 24 h
AA105-MANTA-L6SD/350/W3 3h Sensor+Maintained 16 W / 3 W LED 1750 lm / 250 lm Surface Mounted 24 h
AA105-MANTA-L6SD/500/W3 3h Sensor+Maintained 23 W / 3 W LED 2500 lm / 250 lm Surface Mounted 24 h

Wireless communication, Wi-Fi (802.11 b/g/n) * WELCO compatibility only in emergency mode
Possible to access from anywhere in the world with cloud technology ** Maintained: Lights on mains and stays alight in case of the mains failure. (With battery kit)
Remote monitoring and testing with WELCO software Sensor: Lights on mains through sensor
Indoor and outdoor use
Polycarbonate case
Soft lighting with sanded glass
Microwave radar sensor
MAINS DATA
Adjustable lighting duration PRODUCT STAND-BY RATED RATED MAINS POWER DIMENSIONS WEIGHT QTY
Adjustable night / day working mode CODE POWER (W)* POWER (W)* CURRENT (A)* FACTOR (PF)* (mm) (kg) in CARTON BOX
High energy saving with LED lighting
AA105-MANTA-L6D/350/W3 3,0 23,7 0,140 0,73 320 x 320 x 115 1,70 1
Long life-time (50.000 hours)
AA105-MANTA-L6SD/350/W3 3,7 25,2 0,169 0,64 320 x 320 x 115 1,75 1
4000 K / 6500 K Color temperature
AA105-MANTA-L6SD/500/W3 3,7 32,6 0,198 0,71 320 x 320 x 115 1,75 1
Emergency lighting function by interruption of the unswitched phase
3 hours duration in case of emergency * Measured under 230 V mains.
Status display with green and red LEDs
High-temperature Ni-Cd battery cells
Overcharge and deep discharge protection
Wall and ceiling mounted
Optional - 110 VAC compatibility WIRING DIAGRAM
Optional - LiFePO4 or Ni-MH battery application
As battery kit, EMLUS-SLED/WELCO is used.

230 VAC FR4 -IıIı- EN EN


SELV 50/60 Hz IP 65 PCB SMD Ni - Cd 60598-2-22 62034

In accordance with EN 60598-1, EN 60598-2-22, EN 62034 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz SENSOR TYPE : Microwave Radar Sensor
AMBIENT TEMPERATURE (ta) : -5 °C … +40 °C CASE MATERIAL : Polycarbonate
RATED DURATION : 3h LIGHT SOURCE : SMD LED
BATTERY CHARGING TIME : 24 h PROTECTION CLASS : IP 65
BATTERY TYPE : 3,6 V Ni-Cd INSULATION CLASS : II

LED INDICATION FUNCTIONS


Permanent GREEN Charge mode
Fast flashing GREEN (0,1s on - 0,1s off) Function test
Slow flashing GREEN (1s on - 1s off) Duration test
Permanent RED Load failure
Slow flashing RED (1s on - 1s off) Battery failure
Fast flashing RED (0,1s on - 0,1s off) Charging failure
Double pulsing GREEN Inhibit mode
Binary transmission of address via GREEN/RED Addressing or identification
GREEN and RED off Emergency mode

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 57
EMERGENCY LIGHTING LUMINAIRES
SENSORLIGHT - LED
MANTA LED / WELCO

TECHNICAL DRAWING LIGHT DISTRIBUTION CURVE

PHOTOMETRY DATA
Open Area (Anti-Panic) Lighting Escape Route Lighting
(for min. 0,5 lux) (for min. 1 lux)

Mounting Distance Between Distance Between Mounting Distance Between Distance Between
Height (m) Luminaire and Wall (m) Luminaires (m) Height (m) Luminaire and Wall (m) Luminaires (m)
2,00 2,25 4,00 2,00 2,25 4,25
2,50 2,50 5,00 2,50 2,50 5,00
3,00 2,75 5,50 3,00 2,75 5,50
3,50 3,00 6,25 3,50 2,75 5,75
4,00 3,25 6,50 4,00 2,75 6,25

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 59
WIRED
EMERGENCY LIGHTING
MONITORING SYSTEM
Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 61
ELCO - OVERVIEW

BEŞ A AND DALI MONITORING AND CONTROL PANEL

Digital Addressable Lighting Interface (DALI) is an open communication protocol developed by the leading producers in the CONTROL PANEL
lighting industry and is defined in international IEC 62386 technical standard.
• RTC (Real Time Clock)
DALI protocol, which was developed for controllable lighting ballasts at the beginning, includes many smart lighting • 7 inch touch screen
technologies at the moment and requirements for Emergency Lighting is included in scope of the standard. It provides • 1x RJ45 Ethernet : TCP/IP Internet
maximum flexibility and easiness for system designers, project/installation/montage firms and final users and a very • 1x RS485 input: for 16 x DALI Router connection (max. 2048 DALI
secure and stable communication platform for emergency lighting for monitoring emergency lights in compliance with the compliant emergency lighting device)
Regulation on Fire Protection of Buildings and EN / IEC 50172 Standard. • 230VAC 50/60 Hz
• Functional and duration tests of DALI compliant emergency lighting devices
As an active member of DALI organization, Beş A designs and manufactures DALI compliant emergency lighting products • Status Monitoring of battery and LED lamp
and systems. • Reporting and recording test results

In our R&D laboratory, original circuit designs and embedded software are developed for DALI compliant emergency
lightings units and emergency exit luminaires. With using new technologies; our product family which we manufacture in
our facilities is further expanded. Beş A, as a member of the DiiA organization regulates DALI standards, warrants the DALI
compliance of its products with the ProbitLab - DALI Tester in its R & D Laboratory. Beş A, as a member of DiiA, it applies ROUTER
the DALI logo to its products that pass all tests successfully.
• 2x Outputs: Max. 128 x DALI compliant emergency lighting device
connection
• 1x RS485 input: For connection of touch screen control panel
• 230VAC 50/60Hz
WIRED MONITORING SYSTEM- ELCO

ELCO is our wired monitoring system solution that allows you to monitor status of
DALI compatible emergency lighting products via router and touch screen panel
developed by Beş A.
64 X DALI COMPLIANT EMERGENCY DEVICE
• Central monitoring via touch screen control panel
• Addressable emergency lighting system according to EN and IEC standards 1

LI
DA
• Instant or periodic functional and duration tests
ELCO ROUTER
• Control software for testing, reporting and recording test reports 64 X DALI COMPLIANT EMERGENCY DEVICE

• Password protected user interface

DA
• Omnidirectional and 2-wired standard DALI data bus cabling

LI
2

RS485
ELCO ROUTER

TOUCH SCREEN CONTROL


UNIT WITH Beş A CONTROL
SOFTWARE
3

ELCO ROUTER

16

ELCO ROUTER

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 63
BATTERY AND MAINS DATA
EMERGENCY LIGHTING UNITS - LED PRODUCT
CODE
BATTERY
CAPACITY
RATED
POWER (W)*
MAINS
CURRENT (A)*
POWER
FACTOR (PF)*
DIMENSIONS
(mm)
WEIGHT
(kg)
QTY in
CARTON BOX
EMLUS-SLED / DALI EMLUS-SLED/DALI-2W/3H 3,6 V / 1800 mAh 2,40 0,021 0,48 42 x 234,5 x 23,5 0,130 50
EMLUS-SLED/DALI-3W/1H 3,6 V / 1600 mAh 2,31 0,021 0,47 42 x 234,5 x 23,5 0,130 50
EMLUS-SLED/DALI-3W/3H 3,6 V / 3000 mAh 2,96 0,024 0,52 42 x 234,5 x 23,5 0,130 50

Compatible with panel LED, COB LED and power LED * Measured under 230 V mains.
Compatible with all dimmable and non-dimmable,
constant current LED control gears
Non-maintained operation
EMERGENCY LUMEN FACTOR (2W)
Emergency lighting function by interruption of the unswitched phase LED OPERATING LED OPERATING LED OPERATING LED OPERATING LED OPERATING LED OPERATING
1 - 3 h duration VOLTAGE CURRENT 350mA CURRENT 500mA CURRENT 700mA CURRENT 1050mA CURRENT 1400mA
Electromagnetic Interference (EMI) filter 9 ... 30 VDC %16,50 %11,50 %8,00 %5,50 %4,00
Emergency lighting function in case of low-voltage 31 ... 50 VDC %10,00 %7,00 %5,00 %3,00 -
Constant output power 51 ... 70 VDC %7,00 %5,00 %3,50 - -
Operation range of 9 ... 70 VDC, optional 200 VDC
Short-circuit, open-circuit and overload protection Measured with 3,6 V battery under maximum operating voltage.
Remote control and test with DALI interface
High-temperature Ni-Cd battery cells
Overcharge and deep discharge protection
Polarity reversal protection for battery EMERGENCY LUMEN FACTOR (3W)
Status display with two color LEDs LED OPERATING LED OPERATING LED OPERATING LED OPERATING LED OPERATING LED OPERATING
Simple connectable terminal block VOLTAGE CURRENT 350mA CURRENT 500mA CURRENT 700mA CURRENT 1050mA CURRENT 1400mA
Polycarbonate case
9 ... 30 VDC %26,00 %18,00 %13,00 %8,50 %6,50
Optional - Test switch
31 ... 50 VDC %15,50 %11,00 %7,50 %5,00 -
optional Optional - 110 VAC compatibility
51 ... 70 VDC %11,00 %7,50 %5,50 - -
Optional - LiFePO4 or Ni-MH battery application
Measured with 3,6 V battery under maximum operating voltage.

BATTERY DATA
TÜVRheinland
VOLTAGE CAPACITY CELL TYPE CELL SIZE (mm) QTY OF DIMENSIONS WEIGHT
CELLS (mm) (kg)
230 VAC GW FR4 EN EN EN
SELV 50/60 Hz IP 20 850°C PCB SMD 61347-2-7 61347-2-13 62386 3,6V 1600mAh SC 23 3 23 x 129±3 x 23 0,150
3,6V 1800mAh SC 23 3 23 x 129±3 x 23 0,150
In accordance with EN 61347-1, EN 61347-2-7, EN 62386 standards. 3,6V 3000mAh C 26 3 26 x 150±3 x 26 0,240

Battery dimensions are given without holder. When the holders are added, the length will increase by +40mm and the diameter +5mm.
TECHNICAL DATA Please refer to “Battery Details Table” in “Emergency Lighting Solutions Overview” section of the catalogue for further battery information.

SUPPLY VOLTAGE : 230 VAC 50/60 Hz OUTPUT CURRENT : 25 … 300 mA


AMBIENT TEMPERATURE (ta) : -10 °C … +50 °C OUTPUT VOLTAGE : 9 ... 70 VDC
MAX. CASING TEMPERATURE (tc) : 70 °C OPEN CIRCUIT VOLTAGE : 70 VDC
RATED DURATION : 1/3h PROTECTION CLASS : IP 20
BATTERY CHARGING TIME : 24 h INSULATION CLASS : II
EMERGENCY LUMEN FACTOR (BLF) : %4 ... %26 OUTPUT CURRENT : 40 … 300 mA WIRING DIAGRAM TECHNICAL DRAWING

PRODUCT LIST
PRODUCT OUTPUT LED MODULE OUTPUT LED CURRENT SERIES LED OUTPUT
CODE CURRENT* VOLTAGE RANGE TOLERANCE QUANTITY POWER*
EMLUS-SLED/DALI-2W/3H 25 … 190 mA 9 ... 70 VDC ±%5 3 ... 23 LED 1,75 W
EMLUS-SLED/DALI-3W/1H 40 … 300 mA 9 ... 70 VDC ±%5 3 ... 23 LED 2,75 W
EMLUS-SLED/DALI-3W/3H 40 … 300 mA 9 ... 70 VDC ±%5 3 ... 23 LED 2,75 W

* Measured using maximum LED quantities with 3,6 V battery.

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 65
PRODUCT LIST
EMERGENCY EXIT LUMINAIRES - LED PRODUCT
CODE
RATED
DURATION
OPERATING
MODE*
LIGHT
SOURCE
ROUTING
MODE
TYPE OF
MOUNTING
TUNA L / DALI BYAL-L08/DALI-CY/SU 3h Maintained 12 x SMD LED Double-sided Surface Mounted - Plastic Hanger
BYAL-L08/DALI-CY/SUMA 3h Maintained 12 x SMD LED Double-sided Surface Mounted - Steel Wire
BYAL-L08/DALI-CY/MT 3h Maintained 12 x SMD LED Double-sided Surface Mounted - Metal Hanger
BYAL-L08/DALI-CY/SA 3h Maintained 12 x SMD LED Double-sided Recessed Mounted
Single- or double-sided
Anodized aluminum case * Maintained: Lights on mains and stays alight in case of the mains failure.
Polycarbonate side cover and hanger
SMD LED application
Status display with green and red LEDs
Test switch MAINS DATA
Remote control and test with DALI interface
PRODUCT RATED MAINS POWER DIMENSIONS WEIGHT QTY
High-temperature Ni-Cd battery cells CODE POWER (W)* CURRENT (A)* FACTOR (PF)* (mm) (kg) in CARTON BOX
Overcharge and deep discharge protection
Transparent Plexiglas with screen printed BYAL-L08/DALI-CY/SU 4,82 0,032 0,63 40 x 304 x 235 0,700 1
BYAL-L08/DALI-CY/SUMA 4,82 0,032 0,63 40 x 304 x 235 0,700 1
Side lighting
BYAL-L08/DALI-CY/MT 4,82 0,032 0,63 40 x 304 x 235 0,700 1
Ceiling mounted, ceiling recessed or wall mounted
BYAL-L08/DALI-CY/SA 4,82 0,032 0,63 102 x 372 x 235 1,255 1
Optional - 110 VAC compatibility
Optional - Metal hanger, hook or steel wire
* Measured under 230 V mains.
Optional - LiFePO4 or Ni-MH battery application

RECESSED MOUNTING HOLE SIZE WIRING DIAGRAM

Please refer to “Pictogram Table” in Emergency Exit Luminaries Overview section of the catalogue for alternatives.

230 VAC 41 GW FR4 -IıIı- EN EN


SELV 50/60 Hz IP 20 ALU 850°C PCB SMD Ni - Cd 60598-2-22 62386

In accordance with EN 60598-1, EN 60598-2-22, EN 62386 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz SIGN DIMENSIONS : 180 x 299 mm
AMBIENT TEMPERATURE (ta) : 0 °C … +40 °C VIEWING DISTANCE : 36 m
RATED DURATION : 3h PROTECTION CLASS : IP 20
BATTERY CHARGING TIME : INSULATION CLASS :
24 h I TECHNICAL DRAWING / SURFACE MOUNTED TECHNICAL DRAWING / RECESSED MOUNTED
BATTERY TYPE : 3,6 V Ni-Cd

LED INDICATION FUNCTIONS


Permanent GREEN Charge mode
Fast flashing GREEN (0,1s on - 0,1s off) Function test
Slow flashing GREEN (1s on - 1s off) Duration test
Permanent RED Load failure
Slow flashing RED (1s on - 1s off) Battery failure
Fast flashing RED (0,1s on - 0,1s off) Charging failure
Double pulsing GREEN Inhibit mode
Binary transmission of address via GREEN/RED Addressing or identification
GREEN and RED off Emergency mode

TEST SWITCH FUNCTIONS


Short press (<1s) Starts the function test or terminate the all tests.
Long press (>5s)* Starts the duration test.
* The battery must be 100% full before the duration test can be started.
Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 67
PRODUCT LIST
EMERGENCY EXIT LUMINAIRES - LED
LAPİN LED / DALI PRODUCT
CODE
RATED
DURATION
OPERATING
MODE*
LIGHT
SOURCE
ROUTING
MODE
TYPE OF
MOUNTING
LİPSOS LED / DALI BYAL06-S/LED/DALI 3h Maintained 12 x SMD LED Double-sided (Lapin) Surface Mounted - Plastic Hanger
BYAL06-S/LED/DALI /SA 3h Maintained 12 x SMD LED Double-sided (Lapin) Recessed Mounted
BYAL07-S/LED/DALI 3h Maintained 12 x SMD LED Single-sided (Lipsos) Surface Mounted - Plastic Hanger
BYAL07-S/LED/DALI /SA 3h Maintained 12 x SMD LED Single-sided (Lipsos) Recessed Mounted
Single- or double-sided
Anodized aluminum case * Maintained: Lights on mains and stays alight in case of the mains failure.
Polycarbonate side cover and hanger
SMD LED application
Status display with green and red LEDs
Test switch MAINS DATA
Remote control and test with DALI interface
PRODUCT RATED MAINS POWER DIMENSIONS WEIGHT QTY
High-temperature Ni-Cd battery cells CODE POWER (W)* CURRENT (A)* FACTOR (PF)* (mm) (kg) in CARTON BOX
Overcharge and deep discharge protection
White acrylic plate BYAL06-S/LED/DALI 5,2 0,036 0,63 365 x 43 x 198 0,825 1
BYAL06-S/LED/DALI /SA 5,2 0,036 0,63 425 x 43 x 216 0,955 1
Back lighting
BYAL07-S/LED/DALI 5,2 0,036 0,63 365 x 43 x 198 0,970 1
Ceiling mounted, ceiling recessed or wall mounted
BYAL07-S/LED/DALI /SA 5,2 0,036 0,63 425 x 43 x 216 1,100 1
Optional - 110 VAC compatibility
Optional - Metal hanger, hook or steel wire
* Measured under 230 V mains.
Optional - LiFePO4 or Ni-MH battery application

WIRING DIAGRAM

Please refer to “Pictogram Table” in Emergency Exit Luminaries Overview section of the catalogue for alternatives.

230 VAC 41 GW FR4 -IıIı- EN EN


SELV 50/60 Hz IP 20 ALU 850°C PCB SMD Ni - Cd 60598-2-22 62386

In accordance with EN 60598-1, EN 60598-2-22, EN 62386 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz SIGN DIMENSIONS : 170 x 335 mm
AMBIENT TEMPERATURE (ta) : 0 °C … +40 °C VIEWING DISTANCE : 34 m
RATED DURATION : 3h PROTECTION CLASS : IP 20
BATTERY CHARGING TIME : INSULATION CLASS :
24 h I TECHNICAL DRAWING / SURFACE MOUNTED TECHNICAL DRAWING / RECESSED MOUNTED
BATTERY TYPE : 3,6 V Ni-Cd

LED INDICATION FUNCTIONS


Permanent GREEN Charge mode
Fast flashing GREEN (0,1s on - 0,1s off) Function test
Slow flashing GREEN (1s on - 1s off) Duration test
Permanent RED Load failure
Slow flashing RED (1s on - 1s off) Battery failure
Fast flashing RED (0,1s on - 0,1s off) Charging failure
Double pulsing GREEN Inhibit mode
Binary transmission of address via GREEN/RED Addressing or identification
GREEN and RED off Emergency mode

TEST SWITCH FUNCTIONS


Short press (<1s) Starts the function test or terminate the all tests.
Long press (>5s)* Starts the duration test.
* The battery must be 100% full before the duration test can be started.
Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 69
PRODUCT LIST
EMERGENCY EXIT LUMINAIRES - LED
LAPİN XL LED / DALI PRODUCT
CODE
RATED
DURATION
OPERATING
MODE*
LIGHT
SOURCE
ROUTING
MODE
TYPE OF
MOUNTING
LİPSOS XL LED / DALI BYAL-XL06-LED/DALI-S 3h Maintained 24 X SMD LED Double-sided (Lapin) Surface Mounted - Hook Hanger
BYAL-XL07-LED/DALI-S 3h Maintained 24 X SMD LED Single-sided (Lipsos) Wall Mounted

* Maintained: Lights on mains and stays alight in case of the mains failure.
Single- or double-sided
Anodized aluminum case
Polycarbonate side cover and hanger
SMD LED application
Status display with green and red LEDs
Test switch
Remote control and test with DALI interface
MAINS DATA
High-temperature Ni-Cd battery cells PRODUCT RATED MAINS POWER DIMENSIONS WEIGHT QTY
Overcharge and deep discharge protection CODE POWER (W)* CURRENT (A)* FACTOR (PF)* (mm) (kg) in CARTON BOX
White acrylic plate
BYAL-XL06-LED/DALI-S 6,4 0,044 0,63 630 x 43 x 430 2,400 1
Back lighting
BYAL-XL07-LED/DALI-S 6,4 0,044 0,63 630 x 43 x 430 2,400 1
Ceiling mounted, ceiling recessed or wall mounted
Optional - 110 VAC compatibility
* Measured under 230 V mains.
Optional - Metal hanger, hook or steel wire
Optional - LiFePO4 or Ni-MH battery application

Please refer to “Pictogram Table” in Emergency Exit Luminaries Overview section of the catalogue for alternatives. WIRING DIAGRAM TECHNICAL DRAWING

230 VAC 41 GW FR4 -IıIı- EN EN


SELV 50/60 Hz IP 20 ALU 850°C PCB SMD Ni - Cd 60598-2-22 62386

In accordance with EN 60598-1, EN 60598-2-22, EN 62386 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz SIGN DIMENSIONS : 400 x 600 mm
AMBIENT TEMPERATURE (ta) : 0 °C … +40 °C VIEWING DISTANCE : 80 m
RATED DURATION : 3h PROTECTION CLASS : IP 20
BATTERY CHARGING TIME : 24 h INSULATION CLASS : I
BATTERY TYPE : 3,6 V Ni-Cd

LED INDICATION FUNCTIONS


Permanent GREEN Charge mode
Fast flashing GREEN (0,1s on - 0,1s off) Function test
Slow flashing GREEN (1s on - 1s off) Duration test
Permanent RED Load failure
Slow flashing RED (1s on - 1s off) Battery failure
Fast flashing RED (0,1s on - 0,1s off) Charging failure
Double pulsing GREEN Inhibit mode
Binary transmission of address via GREEN/RED Addressing or identification
GREEN and RED off Emergency mode

TEST SWITCH FUNCTIONS


Short press (<1s) Starts the function test or terminate the all tests.
Long press (>5s)* Starts the duration test.
* The battery must be 100% full before the duration test can be started.
Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 71
PRODUCT LIST
EMERGENCY EXIT LUMINAIRES - LED PRODUCT
CODE
RATED
DURATION
OPERATING
MODE*
LIGHT
SOURCE
ROUTING
MODE
TYPE OF
MOUNTING
ORFOZ / DALI BYPL02-S-XLED2/DALI 3h Maintained 20 x SMD LED Double-sided Surface Mounted

* Maintained: Lights on mains and stays alight in case of the mains failure.

Indoor and outdoor use


Polycarbonate case and glass
Moisture-proof
SMD LED application
High energy saving
Long life-time (50.000 hours)
Emergency lighting function by interruption of the unswitched phase
MAINS DATA
Emergency lighting function in case of low-voltage PRODUCT RATED MAINS POWER DIMENSIONS WEIGHT QTY
3 hours duration in case of emergency CODE POWER (W)* CURRENT (A)* FACTOR (PF)* (mm) (kg) in CARTON BOX
Status display with green and red LEDs
BYPL02-S-XLED2/DALI 5,0 0,036 0,60 122 x 360 x 205 1,025 1
Test switch
Remote control and test with DALI interface
* Measured under 230 V mains.
High-temperature Ni-Cd battery cells
Overcharge and deep discharge protection
Ceiling mounted
Optional - 110 VAC compatibility
Optional - LiFePO4 or Ni-MH battery application

Please refer to “Pictogram Table” in Emergency Exit Luminaries Overview section of the catalogue for alternatives. WIRING DIAGRAM TECHNICAL DRAWING

230 VAC GW FR4 -IıIı- EN EN


SELV 50/60 Hz IP 65 850°C PCB SMD Ni - Cd 60598-2-22 62386

In accordance with EN 60598-1, EN 60598-2-22, EN 62386 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz SIGN DIMENSIONS : 140 x 300 mm
AMBIENT TEMPERATURE (ta) : -5 °C … +40 °C VIEWING DISTANCE : 28 m
RATED DURATION : 3h PROTECTION CLASS : IP 65
BATTERY CHARGING TIME : 24 h INSULATION CLASS : II
BATTERY TYPE : 3,6 V Ni-Cd

LED INDICATION FUNCTIONS


Permanent GREEN Charge mode
Fast flashing GREEN (0,1s on - 0,1s off) Function test
Slow flashing GREEN (1s on - 1s off) Duration test
Permanent RED Load failure
Slow flashing RED (1s on - 1s off) Battery failure
Fast flashing RED (0,1s on - 0,1s off) Charging failure
Double pulsing GREEN Inhibit mode
Binary transmission of address via GREEN/RED Addressing or identification
GREEN and RED off Emergency mode

TEST SWITCH FUNCTIONS


Short press (<1s) Starts the function test or terminate the all tests.
Long press (>5s)* Starts the duration test.
* The battery must be 100% full before the duration test can be started.
Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 73
PRODUCT LIST
EMERGENCY EXIT LUMINAIRES - LED PRODUCT
CODE
RATED
DURATION
OPERATING
MODE*
LIGHT
SOURCE
ROUTING
MODE
TYPE OF
MOUNTING
SOMON-XLED2 / DALI BYPL06-S-XLED2/DALI 3h Maintained 20 x SMD LED Single-sided Surface Mounted

* Maintained: Lights on mains and stays alight in case of the mains failure.

Indoor and outdoor use


Polycarbonate case and glass
Moisture-proof
SMD LED application
High energy saving
Long life-time (50.000 hours)
Emergency lighting function by interruption of the unswitched phase
MAINS DATA
Emergency lighting function in case of low-voltage PRODUCT RATED MAINS POWER DIMENSIONS WEIGHT QTY
3 hours duration in case of emergency CODE POWER (W)* CURRENT (A)* FACTOR (PF)* (mm) (kg) in CARTON BOX
Status display with green and red LEDs
BYPL06-S-XLED2/DALI 5,05 0,036 0,60 108 x 341 x 60 0,630 1
Test switch
Remote control and test with DALI interface
* Measured under 230 V mains.
High-temperature Ni-Cd battery cells
Overcharge and deep discharge protection
Wall mounted
Optional - 110 VAC compatibility
Optional - LiFePO4 or Ni-MH battery application

Please refer to “Pictogram Table” in Emergency Exit Luminaries Overview section of the catalogue for alternatives. WIRING DIAGRAM TECHNICAL DRAWING

230 VAC GW FR4 -IıIı- EN EN


SELV 50/60 Hz IP 65 850°C PCB SMD Ni - Cd 60598-2-22 62386

In accordance with EN 60598-1, EN 60598-2-22, EN 62386 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz SIGN DIMENSIONS : 108 x 341 mm
AMBIENT TEMPERATURE (ta) : -5 °C … +40 °C VIEWING DISTANCE : 21 m
RATED DURATION : 3h PROTECTION CLASS : IP 65
BATTERY CHARGING TIME : 24 h INSULATION CLASS : II
BATTERY TYPE : 3,6 V Ni-Cd

LED INDICATION FUNCTIONS


Permanent GREEN Charge mode
Fast flashing GREEN (0,1s on - 0,1s off) Function test
Slow flashing GREEN (1s on - 1s off) Duration test
Permanent RED Load failure
Slow flashing RED (1s on - 1s off) Battery failure
Fast flashing RED (0,1s on - 0,1s off) Charging failure
Double pulsing GREEN Inhibit mode
Binary transmission of address via GREEN/RED Addressing or identification
GREEN and RED off Emergency mode

TEST SWITCH FUNCTIONS


Short press (<1s) Starts the function test or terminate the all tests.
Long press (>5s)* Starts the duration test.
* The battery must be 100% full before the duration test can be started.
Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 75
EMERGENCY LIGHTING PRODUCT LIST
LUMINAIRES – LED PRODUCT
CODE
RATED
DURATION
OPERATING
MODE*
LIGHT
SOURCE
LIGHT INTENSITY on
ENERGY/EMERGENCY
TYPE of
MOUNTING
BATTERY
CHARGING TIME
RINA / DALI AA104-RINA/DALI/1W 3h Non-Maintained Power LED - / 105 lm Recessed / Surface Mounted 24 h
AA104-RINA/DALI/2W 3h Non-Maintained Power LED - / 205 lm Recessed / Surface Mounted 24 h
AA104-RINA/DALI/3W 3h Non-Maintained Power LED - / 305 lm Recessed / Surface Mounted 24 h
AA104-RINA/DALI/4W 3h Non-Maintained Power LED - / 405 lm Recessed / Surface Mounted 24 h
SMD power LED application
Long life-time (50.000 hours) * Non-maintained : Lights in case of the mains failure.
Emergency lighting function by interruption of the unswitched phase
Emergency lighting function in case of low-voltage
3 hours duration in case of emergency
Status display with green and red LEDs MAINS DATA
Test switch
Remote control and test with DALI interface PRODUCT BATTERY RATED MAINS POWER DIMENSIONS WEIGHT QTY
High-temperature Ni-Cd battery cells CODE CAPACITY POWER (W) * CURRENT (A) * FACTOR (PF)* (mm) (kg) in CARTON BOX
Overcharge and deep discharge protection
AA104-RINA/DALI/1W 3,6V / 900mAh 1,45 0,018 0,35 Spot: 100 x 100 x 25 0,065 1
Polycarbonate case
Unit: 41 x 169,5 x 31,5 0,080
Recessed mounted
Battery: 39 x 221 x 34 0,100
Asymmetric lens
AA104-RINA/DALI/2W 3,6V / 1800mAh 1,65 0,019 0,37 Spot: 100 x 100 x 25 0,065 1
Optional - Symmetric lens application
Unit: 41 x 169,5 x 31,5 0,080
Optional - Surface mounted application
Battery: 39 x 221 x 34 0,165
Optional - LiFePO4 or Ni-MH battery application
AA104-RINA/DALI/3W 3,6V / 3000mAh 2,60 0,024 0,45 Spot: 100 x 100 x 25 0,065 1
Unit: 41 x 169,5 x 31,5 0,080
Battery: 39 x 221 x 34 0,255
AA104-RINA/DALI/4W 3,6V / 4000mAh 3,15 0,027 0,48 Spot: 100 x 100 x 25 0,065 1
Unit: 41 x 169,5 x 31,5 0,080
Battery: 39 x 221 x 34 0,390
* Measured under 230 V mains.

LED SPOT

FR4
BATTERY DATA
230 VAC GW -IıIı- EN
SELV 50/60 Hz IP 20 850°C CEM3 SMD Ni - Cd 60598-2-22
PCB VOLTAGE CAPACITY CELL TYPE CELL SIZE (mm) QTY OF CELLS DIMENSIONS (mm) WEIGHT
(kg)
In accordance with EN 60598-1, EN 60598-2-22, EN 62386 standards. 3,6V 900mAh AA 15 3 15 x 153±3 x 15 0,085
3,6V 1800mAh SC 23 3 23 x 129±3 x 23 0,150
TECHNICAL DATA 3,6V 3000mAh C 26 3 26 x 150±3 x 26 0,240
3,6V 4000mAh D 33 3 33 x 180±3 x 33 0,375
SUPPLY VOLTAGE : 230 VAC 50/60 Hz LIGHT SOURCE : Power LED
AMBIENT TEMPERATURE (ta) : 0 °C … +40 °C DIFFUSER : Symmetric / Asymmetric LENS
RATED DURATION : 3h PROTECTION CLASS : IP 20
BATTERY CHARGING TIME : 24 h INSULATION CLASS : II
BATTERY TYPE : 3,6V Ni-Cd

LED INDICATION FUNCTIONS WIRING DIAGRAM RECESSED MOUNTING HOLE SIZE


Permanent GREEN Charge mode
Fast flashing GREEN (0,1s on - 0,1s off) Function test
Slow flashing GREEN (1s on - 1s off) Duration test
Permanent RED Load failure
Slow flashing RED (1s on - 1s off) Battery failure
Fast flashing RED (0,1s on - 0,1s off) Charging failure
Double pulsing GREEN Inhibit mode
Binary transmission of address via GREEN/RED Addressing or identification
GREEN and RED off Emergency mode

TEST SWITCH FUNCTIONS


Short press (<1s) Starts the function test or terminate the all tests.
Long press (>5s)* Starts the duration test.
* The battery must be 100% full before the duration test can be started.
Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 77
EMERGENCY LIGHTING PHOTOMETRY DATA (3W)
Open Area (Anti-Panic) Lighting (for min. 0,5 lux) Escape Route Lighting (for min. 1 lux)
LUMINAIRES – LED (Symmetric Lens) (Asymmetric Lens)

RINA / DALI
Mounting Distance Between Distance Between Mounting Distance Between Distance Between
Height (m) Luminaire and Wall (m) Luminaires (m) Height (m) Luminaire and Wall (m) Luminaires (m)
TECHNICAL DRAWING (LED SPOT) TECHNICAL DRAWING (EMERGENCY UNIT)
2,00 3,00 5,50 2,00 6,50 11,50
2,50 4,00 7,50 2,50 8,00 15,50
3,00 4,50 8,50 3,00 9,50 18,50
3,50 4,50 10,00 3,50 10,50 21,50
4,00 5,00 11,00 4,00 11,00 24,00

LIGHT DISTRIBUTION CURVE (SYMMETRIC LENS)

TECHNICAL DRAWING (BATTERY BOX)

LIGHT DISTRIBUTION CURVE (ASYMMETRIC LENS)

PHOTOMETRY DATA (1W)


Open Area (Anti-Panic) Lighting (for min. 0,5 lux) Escape Route Lighting (for min. 1 lux)
(Symmetric Lens) (Asymmetric Lens)

Mounting Distance Between Distance Between Mounting Distance Between Distance Between
Height (m) Luminaire and Wall (m) Luminaires (m) Height (m) Luminaire and Wall (m) Luminaires (m)
2,00 2,00 4,00 2,00 5,50 10,50
2,50 2,50 5,00 2,50 7,00 13,50
3,00 2,50 5,00 3,00 6,50 16,00
3,50 3,00 6,00 3,50 6,00 16,50
4,00 3,00 6,50 4,00 3,50 11,50

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 79
EMERGENCY LIGHTING PRODUCT LIST
LUMINAIRES – LED PRODUCT
CODE
RATED
DURATION
OPERATING
MODE*
LIGHT
SOURCE
LIGHT INTENSITY on
ENERGY/EMERGENCY
TYPE of
MOUNTING
BATTERY
CHARGING TIME
SOMON XLED2 / DALI BYPL06-S-XLED2/DALI/1W 3h Maintained 20 x SMD LED 115 lm / 115 lm Recessed / Surface Mounted 24 h
BYPL06-A-XLED2/DALI/1W 3h Non-Maintained 20 x SMD LED - / 115 lm Recessed / Surface Mounted 24 h
BYPL06-A-XLED2/DALI/2W 3h Non-Maintained 20 x SMD LED - / 230 lm Recessed / Surface Mounted 24 h
BYPL06-A-XLED2/DALI/3W 3h Non-Maintained 20 x SMD LED - / 350 lm Recessed / Surface Mounted 24 h
Indoor and outdoor use BYPL06-A-XLED2/DALI/4W 3h Non-Maintained 20 x SMD LED - / 450 lm Recessed / Surface Mounted 24 h
Polycarbonate case and glass
Moisture-proof * Non-maintained : Lights in case of the mains failure.
SMD LED application
High energy saving
Long life-time (50.000 hours)
Emergency lighting function by interruption of the unswitched phase
MAINS DATA
Emergency lighting function in case of low-voltage PRODUCT RATED MAINS POWER DIMENSIONS WEIGHT QTY
3 hours duration in case of emergency CODE POWER (W)* CURRENT (A)* FACTOR (PF)* (mm) (kg) in CARTON BOX
Status display with green and red LEDs
BYPL06-S-XLED2/DALI/1W 5,05 0,036 0,60 108 x 341 x 60 0,630 1
Test switch
BYPL06-A-XLED2/DALI/1W 1,45 0,018 0,35 108 x 341 x 60 0,630 1
Remote control and test with DALI interface
BYPL06-A-XLED2/DALI/2W 1,65 0,019 0,37 108 x 341 x 60 0,690 1
High-temperature Ni-Cd battery cells BYPL06-A-XLED2/DALI/3W 2,60 0,024 0,45 108 x 341 x 60 0,780 1
Overcharge and deep discharge protection BYPL06-A-XLED2/DALI/4W 3,15 0,027 0,48 108 x 341 x 60 0,850 1
Ceiling mounted, ceiling recessed or wall mounted
Optional - 110 VAC compatibility * Measured under 230 V mains.
Optional - LiFePO4 or Ni-MH battery application

WIRING DIAGRAM RECESSED MOUNTING HOLE SIZE

230 VAC GW FR4 -IıIı- EN EN


SELV 50/60 Hz IP 65 SMD Ni - Cd 60598-2-22 62386
850°C PCB

In accordance with EN 60598-1, EN 60598-2-22, EN 62386 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz LIGHT SOURCE : SMD LED
AMBIENT TEMPERATURE (ta) : -5 °C … +40 °C DIFFUSER : Polycarbonate Glass
RATED DURATION : 3h PROTECTION CLASS : IP 65
BATTERY CHARGING TIME : INSULATION CLASS :
BATTERY TYPE :
24 h
3,6 V Ni-Cd
II
TECHNICAL DRAWING / RECESSED
MOUNTED
LED INDICATION FUNCTIONS
Permanent GREEN Charge mode
Fast flashing GREEN (0,1s on - 0,1s off) Function test
Slow flashing GREEN (1s on - 1s off) Duration test
Permanent RED Load failure
Slow flashing RED (1s on - 1s off) Battery failure
Fast flashing RED (0,1s on - 0,1s off) Charging failure
Double pulsing GREEN Inhibit mode
Binary transmission of address via GREEN/RED Addressing or identification
GREEN and RED off Emergency mode

TEST SWITCH FUNCTIONS


Short press (<1s) Starts the function test or terminate the all tests.
Long press (>5s)* Starts the duration test.
* The battery must be 100% full before the duration test can be started.
Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 81
EMERGENCY LIGHTING PHOTOMETRY DATA (3W)
LUMINAIRES – LED Open Area (Anti-Panic) Lighting
(for min. 0,5 lux)
Escape Route Lighting
(for min. 1 lux)

SOMON XLED2 / DALI

Mounting Distance Between Distance Between Mounting Distance Between Distance Between
Height (m) Luminaire and Wall (m) Luminaires (m) Height (m) Luminaire and Wall (m) Luminaires (m)
TECHNICAL DRAWING / SURFACE MOUNTED 2,00 3,00 5,50 2,00 3,00 5,75
2,50 3,50 6,75 2,50 3,50 7,00
3,00 4,00 7,75 3,00 4,00 7,75
3,50 4,25 8,50 3,50 4,25 8,50
4,00 4,50 9,25 4,00 4,25 9,25

LIGHT DISTRIBUTION CURVE

PHOTOMETRY DATA (1W)


Open Area (Anti-Panic) Lighting Escape Route Lighting
(for min. 0,5 lux) (for min. 1 lux)

Mounting Distance Between Distance Between Mounting Distance Between Distance Between
Height (m) Luminaire and Wall (m) Luminaires (m) Height (m) Luminaire and Wall (m) Luminaires (m)
2,00 2,00 3,00 2,00 2,00 3,50
2,50 2,25 4,00 2,50 2,25 4,25
3,00 2,75 4,75 3,00 2,50 4,50
3,50 2,75 5,50 3,50 2,50 5,00
4,00 2,75 6,00 4,00 2,25 5,25

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 83
EMERGENCY LIGHTING PRODUCT LIST
LUMINAIRES – LED PRODUCT
CODE
RATED
DURATION
OPERATING
MODE*
LIGHT
SOURCE
LIGHT INTENSITY on
ENERGY/EMERGENCY
TYPE of
MOUNTING
BATTERY
CHARGING TIME
TETRA PW2 / DALI AA209-PW2/DALI 3h Non-Maintained 2x9W LED - / 1500 lm Surface Mounted 48 h

* Non-maintained : Lights in case of the mains failure.

180° adjustable headlamp


SMD Power LED application
Emergency lighting function by interruption of the unswitched phase
Emergency lighting function in case of low-voltage
3 h duration in case of emergency
Status display with green and red LEDs
MAINS DATA
Test switch PRODUCT RATED MAINS POWER DIMENSIONS WEIGHT QTY
Remote control and test with DALI interface CODE POWER (W)* CURRENT (A)* FACTOR (PF)* (mm) (kg) in CARTON BOX
Maintenance-free sealed lead acid battery
AA209-PW2/DALI 1,25 - 8,90 0,010 - 0,058 0,50 - 0,67 90 x 240 x 200 4,00 1
Overcharge and deep discharge protection
Charging circuit with constant voltage and current protection
* Measured under 230 V mains.
Wall mounted
Maximum values are measured with discharged batteries and values are minimummeasured with full-charged batteries.
Powder coated, white iron sheet case
Optional - 110 VAC compatibility
Optional - LiFePO4 or Ni-MH battery application

WIRING DIAGRAM TECHNICAL DRAWING

LED SPOT

230 VAC FR4 -IıIı- EN EN


SELV 50/60 Hz IP 20 SMD Lead-Acid 60598-2-22 62386
PCB

In accordance with EN 60598-1, EN 60598-2-22, EN 62386 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz HEADLAMP TYPE : 9W LED
AMBIENT TEMPERATURE (ta) : 0 °C … +40 °C CASE MATERIAL : Iron Sheet
RATED DURATION : 3h PROTECTION CLASS : IP 20
BATTERY TYPE : 12V Lead-Acid INSULATION CLASS : I

LED INDICATION FUNCTIONS


Permanent GREEN Charge mode
Fast flashing GREEN (0,1s on - 0,1s off) Function test
Slow flashing GREEN (1s on - 1s off) Duration test
Permanent RED Load failure
Slow flashing RED (1s on - 1s off) Battery failure
Fast flashing RED (0,1s on - 0,1s off) Charging failure
Double pulsing GREEN Inhibit mode
Binary transmission of address via GREEN/RED Addressing or identification
GREEN and RED off Emergency mode

TEST SWITCH FUNCTIONS


Short press (<1s) Starts the function test or terminate the all tests.
Long press (>5s)* Starts the duration test.
* The battery must be 100% full before the duration test can be started.
Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 85
EMERGENCY LIGHTING PRODUCT LIST
LUMINAIRES – LED PRODUCT
CODE
RATED
DURATION
OPERATING
MODE*
LIGHT
SOURCE
LIGHT INTENSITY on
ENERGY/EMERGENCY
TYPE of
MOUNTING
BATTERY
CHARGING TIME
TETRA PW3 / DALI AA209-PW3/DALI 3h Non-Maintained 2x9W LED - / 1500 lm Surface Mounted 48 h

* Non-maintained : Lights in case of the mains failure.

180° adjustable LED headlamp


SMD power LED application
MAINS DATA
Long life-time (30.000 hours) PRODUCT RATED MAINS POWER DIMENSIONS WEIGHT QTY
Emergency lighting function by interruption of the unswitched phase CODE POWER (W)* CURRENT (A)* FACTOR (PF)* (mm) (kg) in CARTON BOX
Emergency lighting function in case of low-voltage AA209-PW3/DALI 1,25 - 8,90 0,010 - 0,058 0,50 - 0,67 98 x 255 x 205 4,50 1
3 hours duration in case of emergency
Status display with green and red LEDs * Measured under 230 V mains.
Test switch Maximum values are measured with discharged batteries and values are minimummeasured with full-charged batteries.
Remote control and test with DALI interface
Maintenance-free sealed lead acid battery
Overcharge and deep discharge protection
Charging circuit with constant voltage and current protect
WIRING DIAGRAM TECHNICAL DRAWING
Wall mounted
ABS case
Optional - 110 VAC compatibility
Optional - LiFePO4 or Ni-MH battery application

LED SPOT

230 VAC FR4 -IıIı- EN EN LIGHT DISTRIBUTION CURVE


SELV 50/60 Hz IP 65 SMD Lead-Acid 60598-2-22 62386
PCB

In accordance with EN 60598-1, EN 60598-2-22, EN 62386 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz HEADLAMP TYPE : 9W LED
AMBIENT TEMPERATURE (ta) : -5 °C … +40 °C CASE MATERIAL : ABS
RATED DURATION : 3h PROTECTION CLASS : IP 65
BATTERY TYPE : 12V Lead-Acid INSULATION CLASS : II

LED INDICATION FUNCTIONS


Permanent GREEN Charge mode
Fast flashing GREEN (0,1s on - 0,1s off) Function test
Slow flashing GREEN (1s on - 1s off) Duration test
Permanent RED Load failure
Slow flashing RED (1s on - 1s off) Battery failure
Fast flashing RED (0,1s on - 0,1s off) Charging failure
Double pulsing GREEN Inhibit mode
Binary transmission of address via GREEN/RED Addressing or identification
GREEN and RED off Emergency mode

TEST SWITCH FUNCTIONS


Short press (<1s) Starts the function test or terminate the all tests. * Above curve is measured data just for one headlamp
Long press (>5s)* Starts the duration test.
* The battery must be 100% full before the duration test can be started.
Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 87
EMERGENCY LIGHTING LUMINAIRES PRODUCT LIST
SENSORLIGHT – LED PRODUCT
CODE*
RATED
DURATION
OPERATING
MODE**
LIGHT
SOURCE
LIGHT INTENSITY on
ENERGY/EMERGENCY
TYPE OF
MOUNTING
BATTERY
CHARGING TIME
MANTA LED / DALI AA105-MANTA-L6D/350/E3 3h Maintained 16 W / 3 W LED 1750 lm / 250 lm Surface Mounted 24 h
AA105-MANTA-L6SD/350/E3 3h Sensor+Maintained 16 W / 3 W LED 1750 lm / 250 lm Surface Mounted 24 h
AA105-MANTA-L6SD/500/E3 3h Sensor+Maintained 23 W / 3 W LED 2500 lm / 250 lm Surface Mounted 24 h

Indoor and outdoor use * DALI compatibility only in emergency mode


Polycarbonate case ** Maintained: Lights on mains and stays alight in case of the mains failure. (With battery kit)
Soft lighting with sanded glass Sensor: Lights on mains through sensor.
Microwave radar sensor
Adjustable lighting duration
Adjustable night / day working mode
High energy saving with LED lighting
MAINS DATA
Long life-time (50.000 hours) PRODUCT STAND-BY RATED MAINS POWER DIMENSIONS WEIGHT QTY
4000 K / 6500 K Color temperature CODE GÜCÜ (W)* POWER (W)* CURRENT (A)* FACTOR (PF)* (mm) (kg) in CARTON BOX
Emergency lighting function by interruption of the unswitched phase
AA105-MANTA-L6D/350/E3 3,0 23,7 0,140 0,73 320 x 320 x 115 1,70 1
3 hours duration in case of emergency
AA105-MANTA-L6SD/350/E3 3,7 25,2 0,169 0,64 320 x 320 x 115 1,75 1
Status display with green and red LEDs
AA105-MANTA-L6SD/500/E3 3,7 32,6 0,198 0,71 320 x 320 x 115 1,75 1
Remote control and test with DALI interface
High-temperature Ni-Cd battery cells * Measured under 230 V mains.
Overcharge and deep discharge protection
Wall and ceiling mounted
Optional - 110 VAC compatibility
Optional - LiFePO4 or Ni-MH battery application
As battery kit, EMLUS-SLED/DALI is used WIRING DIAGRAM

230 VAC FR4 -IıIı- EN EN


SELV 50/60 Hz IP 65 PCB SMD Ni - Cd 60598-2-22 62386

In accordance with EN 60598-1, EN 60598-2-22, EN 62386 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz SENSOR TYPE : Microwave Radar Sensor
AMBIENT TEMPERATURE (ta) : -5 °C … +40 °C CASE MATERIAL : Polycarbonate
RATED DURATION : 3h LIGHT SOURCE : SMD LED
BATTERY CHARGING TIME : 24 h PROTECTION CLASS : IP 65
BATTERY TYPE : 3,6 V Ni-Cd INSULATION CLASS : II

LED INDICATION FUNCTIONS


Permanent GREEN Charge mode
Fast flashing GREEN (0,1s on - 0,1s off) Function test
Slow flashing GREEN (1s on - 1s off) Duration test
Permanent RED Load failure
Slow flashing RED (1s on - 1s off) Battery failure
Fast flashing RED (0,1s on - 0,1s off) Charging failure
Double pulsing GREEN Inhibit mode
Binary transmission of address via GREEN/RED Addressing or identification
GREEN and RED off Emergency mode

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 89
EMERGENCY LIGHTING LUMINAIRES
SENSORLIGHT – LED
MANTA LED / DALI

TECHNICAL DRAWING LIGHT DISTRIBUTION CURVE

PHOTOMETRY DATA
Open Area (Anti-Panic) Lighting Escape Route Lighting
(for min. 0,5 lux) (for min. 1 lux)

Mounting Distance Between Distance Between Mounting Distance Between Distance Between
Height (m) Luminaire and Wall (m) Luminaires (m) Height (m) Luminaire and Wall (m) Luminaires (m)
2,00 2,25 4,00 2,00 2,25 4,25
2,50 2,50 5,00 2,50 2,50 5,00
3,00 2,75 5,50 3,00 2,75 5,50
3,50 3,00 6,25 3,50 2,75 5,75
4,00 3,25 6,50 4,00 2,75 6,25

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 91
SELF-CONTAINED PRODUCTS

EMERGENCY
LIGHTING UNITS
Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice 93
BATTERY AND MAINS DATA
EMERGENCY LIGHTING UNITS - LED PRODUCT
CODE
BATTERY
CAPACITY
RATED
POWER (W)*
MAINS
CURRENT (A)*
POWER
FACTOR (PF)*
DIMENSIONS
(mm)
WEIGHT
(kg)
QTY
in CARTON BOX
EMLUS-SLED / L EMLUS-SLED/L150/1H 3,6 V / 900 mAh 1,95 0,020 0,42 32 x 221 x 22 0,100 50
EMLUS-SLED/L040/3H 3,6 V / 1200 mAh 2,00 0,021 0,42 32 x 221 x 22 0,100 50
EMLUS-SLED/L075/3H 3,6 V / 1600 mAh 2,15 0,021 0,44 32 x 221 x 22 0,100 50
EMLUS-SLED/L150/3H 3,6 V / 1800 mAh 2,18 0,021 0,44 32 x 221 x 22 0,100 50

Compatible with panel LED, COB LED and power LED * Measured under 230 V mains.
Compatible with all dimmable and non-dimmable,
constant current LED control gears
Non-maintained operation
Emergency lighting function by interruption of the unswitched phase
1 - 3 h duration
Electromagnetic Interference (EMI) filter
EMERGENCY LUMEN FACTOR
Emergency lighting function in case of low-voltage LED OPERATING LED OPERATING LED OPERATING LED OPERATING LED OPERATING LED OPERATING
Constant current output VOLTAGE CURRENT 350mA CURRENT 500mA CURRENT 700mA CURRENT 1050mA CURRENT 1400mA
Operation range of 3 ... 150 VDC, optional 200 VDC
3 ... 40 VDC %6,00 %4,00 %3,00 %2,00 %1,50
Short-circuit, open-circuit and overload protection
41 ... 75 VDC %5,00 %3,50 %2,50 - -
High-temperature Ni-Cd battery cells
76 ... 150 VDC %3,00 - - - -
Overcharge and deep discharge protection
Polarity reversal protection for battery Measured with 3,6 V battery under maximum operating voltage.
Charge status display with green LED
Simple connectable terminal block
Polycarbonate case
Optional - Test switch
optional Optional - 110 VAC compatibility
Optional - Ni-MH battery application

BATTERY DATA
VOLTAGE CAPACITY CELL TYPE CELL SIZE (mm) QTY OF CELLS DIMENSIONS (mm) WEIGHT
(kg)
TÜVRheinland

3,6V 900mAh AA 15 3 15 x 153±3 x 15 0,085


230 VAC GW FR4 -IıIı- EN EN 3,6V 1200mAh SC 23 3 23 x 129±3 x 23 0,150
SELV 50/60 Hz IP 20 850°C PCB SMD Ni - Cd 61347-2-7 61347-2-13
3,6V 1600mAh SC 23 3 23 x 129±3 x 23 0,150
3,6V 1800mAh SC 23 3 23 x 129±3 x 23 0,150
In accordance with EN 61347-1, EN 61347-2-7 and EN 61347-2-13 standards.
Battery dimensions are given without holder. When the holders are added, the length will increase by +40mm and the diameter +5mm.
Please refer to “Battery Details Table” in “Emergency Lighting Solutions Overview” section of the catalogue for further battery information.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz OUTPUT CURRENT : 10 … 20 mA
AMBIENT TEMPERATURE (ta) : -10 °C … +50 °C OUTPUT VOLTAGE : 3 ... 150 VDC
MAX. CASING TEMPERATURE (tc) : 70 °C OPEN CIRCUIT VOLTAGE : 0 VDC
RATED DURATION : 1/3h PROTECTION CLASS : IP 20
BATTERY CHARGING TIME : 24 h INSULATION CLASS : II
EMERGENCY LUMEN FACTOR (BLF) : %1,5 … %6 WIRING DIAGRAM TECHNICAL DRAWING

PRODUCT LIST
PRODUCT OUTPUT LED MODULE OUTPUT LED CURRENT SERIES LED OUTPUT
CODE CURRENT* VOLTAGE RANGE TOLERANCE QUANTITY POWER*
EMLUS-SLED/L040 20 mA 3 ... 40 VDC ±%5 1 ... 13 LED 0,80 W
EMLUS-SLED/L075 17 mA 3 ... 75 VDC ±%5 1 ... 25 LED 1,28 W
EMLUS-SLED/L150 10 mA 3 ... 150 VDC ±%5 1 ... 50 LED 1,50 W

* Measured using maximum LED quantities with 3,6 V battery.

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice 95
BATTERY AND MAINS DATA
EMERGENCY LIGHTING UNITS - LED PRODUCT
CODE
BATTERY
CAPACITY
RATED
POWER (W)*
MAINS
CURRENT (A)*
POWER
FACTOR (PF)*
DIMENSIONS
(mm)
WEIGHT
(kg)
QTY
in CARTON BOX
EMLUS-SLED / M EMLUS-SLED/M075/1H 3,6 V / 900 mAh 1,95 0,020 0,42 32 x 221 x 22 0,100 50
EMLUS-SLED/M150/1H 3,6V / 1200 mAh 2,00 0,021 0,42 32 x 221 x 22 0,100 50
EMLUS-SLED/M050/3H 3,6V / 1800 mAh 2,18 0,021 0,44 32 x 221 x 22 0,100 50
EMLUS-SLED/M150/3H 3,6V / 2500 mAh 2,55 0,023 0,48 32 x 221 x 22 0,100 50

Compatible with panel LED, COB LED and power LED * Measured under 230 V mains.
Compatible with all dimmable and non-dimmable,
constant current LED control gears
Non-maintained operation
Emergency lighting function by interruption of the unswitched phase
1 - 3 h duration
Electromagnetic Interference (EMI) filter EMERGENCY LUMEN FACTOR
Emergency lighting function in case of low-voltage
LED OPERATING LED OPERATING LED OPERATING LED OPERATING LED OPERATING LED OPERATING
Constant current output VOLTAGE CURRENT 350mA CURRENT 500mA CURRENT 700mA CURRENT 1050mA CURRENT 1400mA
Operation range of 3 ... 150 VDC, optional 200 VDC
3 ... 40 VDC %14,00 %10,00 %7,00 %5,00 %3,5
Short-circuit, open-circuit and overload protection
41 ... 50 VDC %10,00 %7,00 %5,00 %3,00 -
High-temperature Ni-Cd battery cells
51 ... 75 VDC %7,50 %5,00 %4,00 - -
Overcharge and deep discharge protection
76 ... 150 VDC %5,00 - - - -
Polarity reversal protection for battery
Charge status display with green LED
Measured with 3,6 V battery under maximum operating voltage.
Polycarbonate case
Simple connectable terminal block
Optional - Test switch
optional Optional - 110 VAC compatibility
Optional - Ni-MH battery application

BATTERY DATA
VOLTAGE CAPACITY CELL TYPE CELL SIZE (mm) QTY OF CELLS DIMENSIONS (mm) WEIGHT
(kg)
TÜVRheinland

3,6V 900 mAh AA 15 3 15 x 153±3 x 15 0,085


230 VAC GW FR4 -IıIı- EN EN 3,6V 1200 mAh SC 23 3 23 x 129±3 x 23 0,150
SELV 50/60 Hz IP 20 850°C PCB SMD Ni - Cd 61347-2-7 61347-2-13
3,6V 1800 mAh SC 23 3 23 x 129±3 x 23 0,150
3,6V 2500 mAh C 26 3 26 x 150±3 x 26 0,240
In accordance with EN 61347-1, EN 61347-2-7 and EN 61347-2-13 standards.
Battery dimensions are given without holder. When the holders are added, the length will increase by +40mm and the diameter +5mm.
Please refer to “Battery Details Table” in “Emergency Lighting Solutions Overview” section of the catalogue for further battery information.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz OUTPUT CURRENT : 19 … 33 mA
AMBIENT TEMPERATURE (ta) : -10 °C … +50 °C OUTPUT VOLTAGE : 3 ... 150 VDC
MAX. CASING TEMPERATURE (tc) : 70 °C OPEN CIRCUIT VOLTAGE : 0 VDC
RATED DURATION : 1/3h PROTECTION CLASS : IP 20
BATTERY CHARGING TIME : 24 h INSULATION CLASS : II
EMERGENCY LUMEN FACTOR (BLF) : %3 ... %10 WIRING DIAGRAM TECHNICAL DRAWING

PRODUCT LIST
PRODUCT OUTPUT LED MODULE OUTPUT LED CURRENT SERIES LED OUTPUT
CODE CURRENT* VOLTAGE RANGE TOLERANCE QUANTITY POWER*
EMLUS-SLED/M050 33 mA 3 ... 50 VDC ±%5 1 ... 17 LED 1,7 W
EMLUS-SLED/M075 29 mA 3 ... 75 VDC ±%5 1 ... 25 LED 2,0 W
EMLUS-SLED/M150 19 mA 3 ... 150 VDC ±%5 1 ... 50 LED 2,5 W

* Measured using maximum LED quantities with 3,6 V battery.

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice 97
BATTERY AND MAINS DATA
EMERGENCY LIGHTING UNITS - LED PRODUCT
CODE
BATTERY
CAPACITY
RATED
POWER (W)*
MAINS
CURRENT (A)*
POWER
FACTOR (PF)*
DIMENSIONS
(mm)
WEIGHT
(kg)
QTY
in CARTON BOX
EMLUS-SLED / H EMLUS-SLED/H040/1H 3,6 V / 900 mAh 1,95 0,020 0,42 32 x 221 x 22 0,100 50
EMLUS-SLED/H060/1H 3,6 V / 1200 mAh 2,00 0,021 0,42 32 x 221 x 22 0,100 50
EMLUS-SLED/H090/1H 3,6 V / 1600 mAh 2,15 0,021 0,44 32 x 221 x 22 0,100 50
EMLUS-SLED/H150/1H 3,6 V / 1800 mAh 2,18 0,021 0,44 32 x 221 x 22 0,100 50
EMLUS-SLED/H040/3H 3,6 V / 2500 mAh 2,55 0,023 0,48 32 x 221 x 22 0,100 50
Compatible with panel LED, COB LED and power LED EMLUS-SLED/H060/3H 3,6 V / 3000 mAh 2,75 0,023 0,51 32 x 221 x 22 0,100 50
Compatible with all dimmable and non-dimmable, EMLUS-SLED/H150/3H 3,6 V / 4000 mAh 3,00 0,025 0,52 32 x 221 x 22 0,100 50
constant current LED control gears
* Measured under 230 V mains.
Non-maintained operation
Emergency lighting function by interruption of the unswitched phase
1 - 3 h duration
Electromagnetic Interference (EMI) filter
Emergency lighting function in case of low-voltage EMERGENCY LUMEN FACTOR
Constant current output
Operation range of 3 ... 150 VDC, optional 200 VDC LED OPERATING LED OPERATING LED OPERATING LED OPERATING LED OPERATING LED OPERATING
VOLTAGE CURRENT 350mA CURRENT 500mA CURRENT 700mA CURRENT 1050mA CURRENT 1400mA
Short-circuit, open-circuit and overload protection
High-temperature Ni-Cd battery cells 3 ... 40 VDC %17,00 %12,00 %8,50 %6,00 %4,00
Overcharge and deep discharge protection 41 ... 60 VDC %16,00 %11,00 %8,00 %5,50 -
Polarity reversal protection for battery 61 ... 90 VDC %12,50 %9,00 %6,50 - -
Charge status display with green LED 91 ... 150 VDC %9,00 - - - -
Polycarbonate case
Measured with 3,6 V battery under maximum operating voltage.
Simple connectable terminal block
Optional - Test switch
optional Optional - 110 VAC compatibility
Optional - Ni-MH battery application

BATTERY DATA
VOLTAGE CAPACITY CELL TYPE CELL SIZE (mm) QTY OF CELLS DIMENSIONS (mm) WEIGHT
TÜVRheinland
(kg)

3,6V 900 mAh AA 15 3 15 x 153±3 x 15 0,085


230 VAC GW FR4 -IıIı- EN EN 3,6V 1200 mAh SC 23 3 23 x 129±3 x 23 0,150
SELV 50/60 Hz IP 20 850°C PCB SMD Ni - Cd 61347-2-7 61347-2-13
3,6V 1600 mAh SC 23 3 23 x 129±3 x 23 0,150
3,6V 1800 mAh SC 23 3 23 x 129±3 x 23 0,150
In accordance with EN 61347-1, EN 61347-2-7 and EN 61347-2-13 standards. 3,6V 2500 mAh C 26 3 26 x 150±3 x 26 0,240
3,6V 3000 mAh C 26 3 26 x 150±3 x 26 0,240
3,6V 4000 mAh D 33 3 33 x 180±3 x 33 0,375

Battery dimensions are given without holder. When the holders are added, the length will increase by +40mm and the diameter +5mm.
TECHNICAL DATA Please refer to “Battery Details Table” in “Emergency Lighting Solutions Overview” section of the catalogue for further battery information.

SUPPLY VOLTAGE : 230 VAC 50/60 Hz OUTPUT CURRENT : 30 … 63 mA


AMBIENT TEMPERATURE (ta) : -10 °C … +50 °C OUTPUT VOLTAGE : 3 ... 150 VDC
MAX. CASING TEMPERATURE (tc) : 70 °C OPEN CIRCUIT VOLTAGE : 0 VDC
RATED DURATION : 1/3h PROTECTION CLASS : IP 20
BATTERY CHARGING TIME : 24 h INSULATION CLASS : II
EMERGENCY LUMEN FACTOR (BLF) : %5,5 ... %17 WIRING DIAGRAM TECHNICAL DRAWING

PRODUCT LIST
PRODUCT OUTPUT LED MODULE OUTPUT LED CURRENT SERIES LED OUTPUT
CODE CURRENT* VOLTAGE RANGE TOLERANCE QUANTITY POWER*
EMLUS-SLED/H040 63 mA 3 ... 40 VDC ±%5 1 ... 13 LED 2,4 W
EMLUS-SLED/H060 55 mA 3 ... 60 VDC ±%5 1 ... 20 LED 3,3 W
EMLUS-SLED/H090 45 mA 3 ... 90 VDC ±%5 1 ... 30 LED 4,0 W
EMLUS-SLED/H150 30 mA 3 ... 150 VDC ±%5 1 ... 50 LED 4,6 W

* Measured using maximum LED quantities with 3,6 V battery.

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice 99
BATTERY AND MAINS DATA
EMERGENCY LIGHTING UNITS - LED PRODUCT
CODE
BATTERY
CAPACITY
RATED
POWER (W)*
MAINS
CURRENT (A)*
POWER
FACTOR (PF)*
DIMENSIONS
(mm)
WEIGHT
(kg)
QTY
in CARTON BOX
EMLUS-LED / LX2 EMLUS-LED/LX2-150/1H 3,6 V / 900 mAh 3,03 0,014 0,94 41 x 169,5 x 31,5 0,180 30
EMLUS-LED/LX2-040/3H 3,6 V / 1200 mAh 3,06 0,014 0,95 41 x 169,5 x 31,5 0,180 30
EMLUS-LED/LX2-075/3H 3,6 V / 1600 mAh 3,40 0,015 0,96 41 x 169,5 x 31,5 0,180 30
EMLUS-LED/LX2-150/3H 3,6 V / 1800 mAh 3,40 0,015 0,96 41 x 169,5 x 31,5 0,180 30
* Measured under 230 V mains.
Compatible with panel LED, COB LED and power LED
Compatible with all dimmable and non-dimmable,
constant current LED control gears
Non-maintained operation
Emergency lighting function by interruption of the unswitched phase
1 - 3 h duration
Constant current output EMERGENCY LUMEN FACTOR
Operation range of 3 ... 150 VDC, optional 200 VDC
Short-circuit, open-circuit and overload protection LED OPERATING LED OPERATING LED OPERATING LED OPERATING LED OPERATING LED OPERATING
VOLTAGE CURRENT 350mA CURRENT 500mA CURRENT 700mA CURRENT 1050mA CURRENT 1400mA
High-temperature Ni-Cd battery cells
Overcharge and deep discharge protection 3 ... 40 VDC %6,00 %4,00 %3,00 %2,00 %1,50
Polarity reversal protection for battery 41 ... 75 VDC %5,00 %3,50 %2,50 - -
Charge status display with green LED 76 ... 150 VDC %3,00 - - - -
Polycarbonate case Measured with 3,6 V battery under maximum operating voltage.
Simple connectable terminal block
Optional - 110 VAC compatibility

BATTERY DATA
VOLTAGE CAPACITY CELL TYPE CELL SIZE (mm) QTY OF CELLS DIMENSIONS (mm) WEIGHT
(kg)
230 VAC GW CEM1 -IıIı- EN EN
3.6V 900mAh AA 15 3 15 x 153±3 x 15 0,085
SELV 50/60 Hz IP 20 850°C PBC SMD Ni - Cd 61347-2-7 61347-2-13
3.6V 1200mAh SC 23 3 23 x 129±3 x 23 0,150
3.6V 1600mAh SC 23 3 23 x 129±3 x 23 0,150
In accordance with EN 61347-1, EN 61347-2-7 and EN 61347-2-13 standards. 1800mAh SC 23 3 23 x 129±3 x 23 0,150
3.6V

Battery dimensions are given without holder. When the holders are added, the length will increase by +40mm and the diameter +5mm.
Please refer to “Battery Details Table” in “Emergency Lighting Solutions Overview” section of the catalogue for further battery information.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz OUTPUT CURRENT : 10 … 20 mA
AMBIENT TEMPERATURE (ta) : -10 °C … +50 °C OUTPUT VOLTAGE : 3 ... 150 VDC
MAX. CASING TEMPERATURE (tc) : 70 °C OPEN CIRCUIT VOLTAGE : 0 VDC
RATED DURATION : 1/3h PROTECTION CLASS : IP 20
BATTERY CHARGING TIME : 24 / 48 h INSULATION CLASS : II
EMERGENCY LUMEN FACTOR (BLF) : %1,5 … %6 WIRING DIAGRAM TECHNICAL DRAWING

PRODUCT LIST
PRODUCT OUTPUT LED MODULE OUTPUT LED CURRENT SERIES LED OUTPUT
CODE CURRENT* VOLTAGE RANGE TOLERANCE QUANTITY POWER*
EMLUS-LED/LX2-040 20 mA 3 ... 40 VDC ±5% 1 ... 13 LED 0,80 W
EMLUS-LED/LX2-075 17 mA 3 ... 75 VDC ±5% 1 ... 25 LED 1,28 W
EMLUS-LED/LX2-150 10 mA 3 ... 150 VDC ±5% 1 ... 50 LED 1,50 W
* Measured using maximum LED quantities with 3,6 V battery.

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice 101
BATTERY AND MAINS DATA
EMERGENCY LIGHTING UNITS - LED PRODUCT
CODE
BATTERY
CAPACITY
RATED
POWER (W)*
MAINS
CURRENT (A)*
POWER
FACTOR (PF)*
DIMENSIONS
(mm)
WEIGHT
(kg)
QTY
in CARTON BOX
EMLUS-LED / MX2 EMLUS-LED/MX2-075/1H 3,6 V / 900 mAh 3,03 0,014 0,94 41 x 169,5 x 31,5 0,180 30
EMLUS-LED/MX2-150/1H 3,6 V / 1200 mAh 3,06 0,014 0,95 41 x 169,5 x 31,5 0,180 30
EMLUS-LED/MX2-050/3H 3,6 V / 1800 mAh 3,40 0,015 0,96 41 x 169,5 x 31,5 0,180 30
EMLUS-LED/MX2-150/3H 3,6 V / 2500 mAh 3,65 0,016 0,97 41 x 169,5 x 31,5 0,180 30
* Measured under 230 V mains.
Compatible with panel LED, COB LED and power LED
Compatible with all dimmable and non-dimmable,
constant current LED control gears
Non-maintained operation
Emergency lighting function by interruption of the unswitched phase
1 - 3 h duration
Constant current output EMERGENCY LUMEN FACTOR
Operation range of 3 ... 150 VDC, optional 200 VDC
LED OPERATING LED OPERATING LED OPERATING LED OPERATING LED OPERATING LED OPERATING
Short-circuit, open-circuit and overload protection VOLTAGE CURRENT 350mA CURRENT 500mA CURRENT 700mA CURRENT 1050mA CURRENT 1400mA
High-temperature Ni-Cd battery cells
3 ... 40 VDC %14,00 %10,00 %7,00 %5,00 %3,50
Overcharge and deep discharge protection
41 ... 50 VDC %10,00 %7,00 %5,00 %3,00 -
Polarity reversal protection for battery
51 ... 75 VDC %7,50 %5,00 %4,00 - -
Charge status display with green LED
76 ... 150 VDC %5,00 - - - -
Polycarbonate case
Simple connectable terminal block Measured with 3,6 V battery under maximum operating voltage.
Optional - 110 VAC compatibility

BATTERY DATA
VOLTAGE CAPACITY CELL TYPE CELL SIZE (mm) QTY OF CELLS DIMENSIONS (mm) WEIGHT
(kg)
230 VAC GW CEM1 -IıIı- EN EN
3,6V 900 mAh AA 15 3 15 x 153±3 x 15 0,085
SELV 50/60 Hz IP 20 850°C PBC SMD Ni - Cd 61347-2-7 61347-2-13
3,6V 1200 mAh SC 23 3 23 x 129±3 x 23 0,150
3,6V 1800 mAh SC 23 3 23 x 129±3 x 23 0,150
In accordance with EN 61347-1, EN 61347-2-7 and EN 61347-2-13 standards. 2500 mAh C 26 3 26 x 150±3 x 26 0,240
3,6V

Battery dimensions are given without holder. When the holders are added, the length will increase by +40mm and the diameter +5mm.
Please refer to “Battery Details Table” in “Emergency Lighting Solutions Overview” section of the catalogue for further battery information.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz OUTPUT CURRENT : 19 … 33 mA
AMBIENT TEMPERATURE (ta) : -10 °C … +50 °C OUTPUT VOLTAGE : 3 ... 150 VDC
MAX. CASING TEMPERATURE (tc) : 70 °C OPEN CIRCUIT VOLTAGE : 0 VDC
RATED DURATION : 1/3h PROTECTION CLASS : IP 20
BATTERY CHARGING TIME : 24 / 48 h INSULATION CLASS : II
EMERGENCY LUMEN FACTOR (BLF) : %3 ... %10 WIRING DIAGRAM TECHNICAL DRAWING

PRODUCT LIST
PRODUCT OUTPUT LED MODULE OUTPUT LED CURRENT SERIES LED OUTPUT
CODE CURRENT* VOLTAGE RANGE TOLERANCE QUANTITY POWER*
EMLUS-LED/MX2-050 33 mA 3 ... 50 VDC ±5% 1 ... 17 LED 1,7 W
EMLUS-LED/MX2-075 29 mA 3 ... 75 VDC ±5% 1 ... 25 LED 2,0 W
EMLUS-LED/MX2-150 19 mA 3 ... 150 VDC ±5% 1 ... 50 LED 2,5 W
* Measured using maximum LED quantities with 3,6 V battery.

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice 103
BATTERY AND MAINS DATA
EMERGENCY LIGHTING UNITS - LED PRODUCT
CODE
BATTERY
CAPACITY
RATED
POWER (W)*
MAINS
CURRENT (A)*
POWER
FACTOR (PF)*
DIMENSIONS
(mm)
WEIGHT
(kg)
QTY
in CARTON BOX
EMLUS-LED / HX2 EMLUS-LED/HX2-040/1H 3,6 V / 900 mAh 3,03 0,014 0,94 41 x 169,5 x 31,5 0,180 30
EMLUS-LED/HX2-060/1H 3,6 V / 1200 mAh 3,06 0,014 0,95 41 x 169,5 x 31,5 0,180 30
EMLUS-LED/HX2-090/1H 3,6 V / 1600 mAh 3,40 0,015 0,96 41 x 169,5 x 31,5 0,180 30
EMLUS-LED/HX2-150/1H 3,6 V / 1800 mAh 3,40 0,015 0,96 41 x 169,5 x 31,5 0,180 30
EMLUS-LED/HX2-040/3H 3,6 V / 2500 mAh 3,65 0,016 0,97 41 x 169,5 x 31,5 0,180 30
Compatible with panel LED, COB LED and power LED EMLUS-LED/HX2-060/3H 3,6 V / 3000 mAh 3,65 0,016 0,97 41 x 169,5 x 31,5 0,180 30
Compatible with all dimmable and non-dimmable, EMLUS-LED/HX2-150/3H 3,6 V / 4000 mAh 3,65 0,016 0,97 41 x 169,5 x 31,5 0,180 30
constant current LED control gears
Non-maintained operation * Measured under 230 V mains.
Emergency lighting function by interruption of the unswitched phase
1 - 3 h duration
Constant current output EMERGENCY LUMEN FACTOR
Operation range of 3 ... 150 VDC, optional 200 VDC
Short-circuit, open-circuit and overload protection LED OPERATING LED OPERATING LED OPERATING LED OPERATING LED OPERATING LED OPERATING
VOLTAGE CURRENT 350mA CURRENT 500mA CURRENT 700mA CURRENT 1050mA CURRENT 1400mA
High-temperature Ni-Cd battery cells
Overcharge and deep discharge protection 3 ... 40 VDC %17,00 %12,00 %8,50 %6,00 %4,00
Polarity reversal protection for battery 41 ... 60 VDC %16,00 %11,00 %8,00 %5,50 -
Charge status display with green LED 61 ... 90 VDC %12,50 %9,00 %6,50 - -
Polycarbonate case 91 ... 150 VDC %9,00 - - - -
Simple connectable terminal block Measured with 3,6 V battery under maximum operating voltage.
Optional - 110 VAC compatibility

BATTERY DATA
VOLTAGE CAPACITY CELL TYPE CELL SIZE (mm) QTY OF CELLS DIMENSIONS (mm) WEIGHT
(kg)

3,6V 900 mAh AA 15 3 15 x 153±3 x 15 0,085


3,6V 1200 mAh SC 23 3 23 x 129±3 x 23 0,150
230 VAC GW CEM1 -IıIı- EN EN
SELV 50/60 Hz IP 20 850°C PBC SMD Ni - Cd 61347-2-7 61347-2-13 3,6V 1600 mAh SC 23 3 23 x 129±3 x 23 0,150
3,6V 1800 mAh SC 23 3 23 x 129±3 x 23 0,150
3,6V 2500 mAh C 26 3 26 x 150±3 x 26 0,240
In accordance with EN 61347-1, EN 61347-2-7 and EN 61347-2-13 standards.
3,6V 3000 mAh C 26 3 26 x 150±3 x 26 0,240
3,6V 4000 mAh D 33 3 33 x 180±3 x 33 0,375

Battery dimensions are given without holder. When the holders are added, the length will increase by +40mm and the diameter +5mm.
TECHNICAL DATA Please refer to “Battery Details Table” in “Emergency Lighting Solutions Overview” section of the catalogue for further battery information.

SUPPLY VOLTAGE : 230 VAC 50/60 Hz OUTPUT CURRENT : 30 … 63 mA


AMBIENT TEMPERATURE (ta) : -10 °C … +50 °C OUTPUT VOLTAGE : 3 ... 150 VDC
MAX. CASING TEMPERATURE (tc) : 70 °C OPEN CIRCUIT VOLTAGE : 0 VDC
RATED DURATION : 1/3h PROTECTION CLASS : IP 20
BATTERY CHARGING TIME : 24 / 48 h INSULATION CLASS : II
EMERGENCY LUMEN FACTOR (BLF) : %5,5 ... %17 WIRING DIAGRAM TECHNICAL DRAWING

PRODUCT LIST
PRODUCT OUTPUT LED MODULE OUTPUT LED CURRENT SERIES LED OUTPUT
CODE CURRENT* VOLTAGE RANGE TOLERANCE QUANTITY POWER*
EMLUS-LED/HX2-040 63 mA 3 ... 40 VDC ±5% 1 ... 13 LED 2,4 W
EMLUS-LED/HX2-060 55 mA 3 ... 60 VDC ±5% 1 ... 20 LED 3,3 W
EMLUS-LED/HX2-090 45 mA 3 ... 90 VDC ±5% 1 ... 30 LED 4,0 W
EMLUS-LED/HX2-150 30 mA 3 ... 150 VDC ±5% 1 ... 50 LED 4,6 W
* Measured using maximum LED quantities with 3,6 V battery.

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice 105
BATTERY AND MAINS DATA
EMERGENCY LIGHTING UNITS - LED PRODUCT
CODE
BATTERY
CAPACITY
RATED
POWER (W)*
MAINS
CURRENT (A)*
POWER
FACTOR (PF)*
DIMENSIONS
(mm)
WEIGHT
(kg)
QTY
in CARTON BOX
EMLUS-12V/24V EMLUS-12V-008W 12 V / 900 mAh (1 h) 3,55 0,022 0,68 43 x 185 x 34 0,200 30
EMLUS-12V-015W 12 V / 1600 mAh (1 h) 4,30 0,024 0,76 43 x 185 x 34 0,200 30
EMLUS-12V-030W 12 V / 4000 mAh (1 h) 5,45 0,028 0,83 43 x 185 x 34 0,200 30
EMLUS-12V-050W 12 V / 5000 mAh (1 h) 6,25 0,031 0,86 43 x 185 x 34 0,200 30
Compatible with 12 V and 24 V LED Strip
EMLUS-24V-015W 24 V / 900 mAh (1 h) 7,10 0,035 0,89 43 x 185 x 34 0,200 30
Compatible with all dimmable and non-dimmable,
EMLUS-24V-030W 24 V / 1600 mAh (1 h) 8,75 0,042 0,91 43 x 185 x 34 0,200 30
constant current LED control gears
EMLUS-24V-060W 24 V / 4000 mAh (1 h) 8,75 0,042 0,91 43 x 185 x 34 0,200 30
Non-maintained operation
EMLUS-24V-100W 24 V / 5000 mAh (1 h) 8,75 0,042 0,91 43 x 185 x 34 0,200 30
Emergency lighting function by interruption of the unswitched phase
1 h duration
Constant voltage output * Measured under 230 V mains.
Sustained constant 100% lighting
Operation range of 3 ... 150 VDC, optional 200 VDC
Short-circuit, open-circuit and overload protection
High-temperature Ni-Cd battery cells BATTERY DATA
Overcharge and deep discharge protection
Polarity reversal protection for battery VOLTAGE CAPACITY CELL TYPE CELL SIZE (mm) QTY OF CELLS DIMENSIONS (mm) WEIGHT
(kg)
Charge status display with green LED
Polycarbonate case 12 V / 900 mAh 900mAh AA 15 10 30 x 255±3 x 15 0,285
Simple connectable terminal block 12 V / 1600 mAh 1600mAh SC 23 10 46 x 215±3 x 23 0,500
Optional - 110 VAC compatibility 12 V / 4000 mAh 4000mAh D 33 10 66 x 300±3 x 33 1,250
12 V / 5000 mAh 2500mAh C 26 20 52 x 250±3 x 52 1,600

24 V / 900 mAh 900mAh AA 15 20 30 x 255±3 x 15 0,570


24 V / 1600 mAh 1600mAh SC 23 20 46 x 215±3 x 23 1,000
24 V / 4000 mAh 4000mAh D 33 20 66 x 300±3 x 33 2,500
24 V / 5000 mAh 2500mAh C 26 40 52 x 250±3 x 52 3,200

Please refer to “Battery Details Table” in “Emergency Lighting Solutions Overview” section of the catalogue for further battery information.

230 VAC GW CEM1 -IıIı- EN EN


SELV 50/60 Hz IP 20 850°C PCB SMD Ni - Cd 61347-2-7 61347-2-13

In accordance with EN 61347-1, EN 61347-2-7 and EN 61347-2-13 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz MAX. OUTPUT POWER : 12 V – 50 W / 24 V – 100 W WIRING DIAGRAM TECHNICAL DRAWING
AMBIENT TEMPERATURE (ta) : -10 °C … +50 °C OUTPUT VOLTAGE : 10 ... 14 VDC / 20 … 28 VDC
MAX. CASING TEMPERATURE (tc) : 70 °C OPEN CIRCUIT VOLTAGE : 10 ... 14 VDC / 20 … 28 VDC
RATED DURATION : 1h PROTECTION CLASS : IP 20
BATTERY CHARGING TIME : 24 / 72 h INSULATION CLASS : II
EMERGENCY LUMEN FACTOR (BLF) : %100

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice 107
BATTERY DATA
EMERGENCY LIGHTING UNITS - LED VOLTAGE CAPACITY CELL TYPE CELL SIZE (mm) QTY OF CELLS DIMENSIONS (mm) WEIGHT
(kg)
EMLUS-220 7,2V/3000mAh 3000 mAh C 26 6 26 x 300±3 x 26 0,480
7,2V/6000mAh 3000 mAh C 26 12 52 x 300±3 x 26 0,960
12V/3000mAh 3000 mAh C 26 10 52 x 250±3 x 26 0,800
12V/4000mAh 4000 mAh D 33 10 66 x 300±3 x 33 1,250
12V/5000mAh 2500 mAh C 26 20 52 x 250±3 x 52 1,600
Compatible with 220 V LED tube and spot lighting 12V/6000mAh 3000 mAh C 26 20 52 x 250±3 x 52 1,600
Sustained constant 100% lighting 12V/8000mAh 4000 mAh D 33 20 66 x 300±3 x 66 2,600
Non-maintained operation
Emergency lighting function by interruption of the unswitched phase Please refer to “Battery Details Table” in “Emergency Lighting Solutions Overview” section of the catalogue for further battery
1 - 3 h duration information.
DC voltage supply for LED Driver
Short-circuit, open-circuit and overload protection
High-temperature Ni-Cd battery cells
Overcharge and deep discharge protection
Polarity reversal protection for battery
Charge status display with green LED
Polycarbonate case WIRING DIAGRAM TECHNICAL DRAWING
Simple connectable terminal block
Optional - 110 VAC compatibility

LED SPOT LED LAMP

230 VAC GW CEM1 -IıIı- EN


50/60 Hz IP 20 850°C PCB SMD Ni - Cd 61347-2-7

In accordance with EN 61347-1, EN 61347-2-7 and EN 61347-2-13 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50 / 60 Hz EMERGENCY LUMEN FACTOR (BLF) : %100
AMBIENT TEMPERATURE (ta) : -10°C … +50 °C MAX. OUTPUT POWER : 30 W
MAX. CASING TEMPERATURE (tc) : 70 °C OUTPUT VOLTAGE : 200 ... 340 VDC
RATED DURATION : 1/3h PROTECTION CLASS : IP 20
BATTERY CHARGING TIME : 24 / 96 h INSULATION CLASS : II

PRODUCT LIST
PRODUCT BATTERY RATED MAINS POWER DIMENSIONS WEIGHT QTY
CODE CAPACITY POWER (W)* CURRENT (A)* FACTOR (PF)* (mm) (kg) in CARTON BOX
7,2 V / 3000 mAh (1 h) 4,70 0.023 0.86
EMLUS-220/10W 42 x 264 x 34 0,285 25
7,2 V / 6000 mAh (3 h) 6,30 0.030 0,90
12 V / 3000 mAh (1 h) 6,75 0.034 0.87
EMLUS-220/20W 42 x 264 x 34 0,285 25
12 V / 6000 mAh (3 h) 6,75 0.034 0.87
12 V / 4000 mAh (1 h) 6,75 0.034 0.87
EMLUS-220/25W 42 x 264 x 34 0,285 25
12 V / 8000 mAh (3 h) 6,75 0.034 0.87
6,75 0.034 0.87
EMLUS-220/30W 12 V / 5000 mAh (1 h) 42 x 264 x 34 0,285 25
6,75 0.034 0.87
* Measured under 230 V mains.
Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice 109
BATTERY DATA
EMERGENCY LIGHTING UNITS - LED VOLTAGE CAPACITY CELL TYPE CELL SIZE (mm) QTY OF CELLS DIMENSIONS (mm) WEIGHT
(kg)
EMLUS-220 SPOT 4,8 V 1800 mAh SC 23 4 23 x 180±4 x 23 0,200
4,8 V 4000 mAh D 33 4 33 x 248±4 x 33 0,520

Please refer to “Battery Details Table” in “Emergency Lighting Solutions Overview” section of the catalogue for
further battery information.
Compatible with 220 V / up to 5 W LED spot
Sustained constant 100% lighting
Non-maintained operation
Emergency lighting function by interruption of the unswitched phase
1 - 3 h duration
DC voltage supply for LED Driver
Short-circuit, open-circuit and overload protection
High-temperature Ni-Cd battery cells WIRING DIAGRAM TECHNICAL DRAWING
Overcharge and deep discharge protection
Polarity reversal protection for battery
Charge status display with green LED
Polycarbonate case
Simple connectable terminal block
Optional - 110 VAC compatibility

LED SPOT

230 VAC GW CEM1 -IıIı- EN


50/60 Hz IP 20 PCB SMD Ni - Cd 61347-2-7
850°C

In accordance with EN 61347-1, EN 61347-2-7 and EN 61347-2-13 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50 / 60 Hz EMERGENCY LUMEN FACTOR (BLF) : %100
AMBIENT TEMPERATURE (ta) : -10°C … +50 °C MAX. OUTPUT POWER : 5W
MAX. CASING TEMPERATURE (tc) : 70 °C OUTPUT VOLTAGE : 160 ... 310 VDC
RATED DURATION : 1/3h PROTECTION CLASS : IP 20
BATTERY CHARGING TIME : 24 / 48 h INSULATION CLASS : II

PRODUCT LIST
PRODUCT BATTERY RATED MAINS POWER DIMENSIONS WEIGHT QTY
CODE CAPACITY POWER (W)* CURRENT (A)* FACTOR (PF)* (mm) (kg) in CARTON BOX

4,8 V / 1800 mAh (1 h) 3,55 0,019 0,80 43 x 185 x 34 0,225 30


EMLUS-220/5W
4,8 V / 4000 mAh (3 h) 4,60 0,023 0,86 43 x 185 x 34 0,225 30

* Measured under 230 V mains.

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice 111
BATTERY AND MAINS DATA
EMERGENCY LIGHTING UNITS
PRODUCT BATTERY RATED MAINS POWER DIMENSIONS WEIGHT QTY
FLUORESCENT LAMP CODE CAPACITY POWER (W)* CURRENT (A)* FACTOR (PF)* (mm) (kg) in CARTON BOX

EMLUS-FLS EMLUS-FLS/A/1H 3,6 V / 900 mAh (1 h) 2,25 0,021 0,48 42 x 234,5 x 23,5
42 x 234,5 x 23,5
0,140 30
EMLUS-FLS/A/3H 3,6 V / 2500 mAh (3 h) 2,95 0,024 0,52 0,140 30
EMLUS-FLS/B/1H 3,6 V / 1200 mAh (1 h) 2,50 0,022 0,50 42 x 234,5 x 23,5 0,140 30
EMLUS-FLS/B/3H 3,6 V / 3000 mAh (3 h) 2,95 0,024 0,52 42 x 234,5 x 23,5 0,140 30
Compatible with electronic and magnetic ballast EMLUS-FLS/C/1H 3,6 V / 1600 mAh (1 h) 2,75 0,023 0,50 42 x 234,5 x 23,5 0,140 30
Non-maintained operation EMLUS-FLS/C/3H 3,6 V / 4000 mAh (3 h) 3,60 0,029 0,55 42 x 234,5 x 23,5 0,140 30
Emergency lighting function by interruption of the unswitched phase EMLUS-FLS/D/1H 4,8 V / 1800 mAh (1 h) 3,80 0,030 0,56 42 x 234,5 x 23,5 0,140 30
1 - 3 h duration EMLUS-FLS/D/3H 4,8 V / 4000 mAh (3 h) 5,50 0,041 0,60 42 x 234,5 x 23,5 0,140 30
Emergency lighting function in case of low-voltage
Compatible with 4-pin fluorescent lamps * Measured under 230 V mains.
Prolonging the lamp life with warm-start
Short-circuit, open-circuit and overload protection
High-temperature Ni-Cd battery cells EMERGENCY LUMEN FACTOR
Overcharge and deep discharge protection PRODUCT FLUORESCENT LAMP TYPE & LAMP POWER
Polarity reversal protection for battery 4-pin T8 4-pin T5 4-pin PLL 4-pin PLC
Charge status display with green LED
EMLUS-FLS/A 18W(%11) 13W(%18) 14W(%17) 11W(%20) 18W(%13) 13W(%20)
Polycarbonate case
EMLUS-FLS/B 36W(%8) 24W(%11) 24W(%10) 36W(%13) 18W(%20) 26W(%14)
Simple connectable terminal block
EMLUS-FLS/C 58W(%7) 21W(%15) 39W(%14) 55W(%10) -
Optional - Ni-MH battery application
EMLUS-FLS/D - 28W(%13) 35W(%10) 49W(%10) - 32W(%13) 42W(%13)
Optional - 110 VAC compatibility
54W(%12) 80W(%8)

Measured with 3,6 V battery under maximum operating voltage.


optional

TÜVRheinland TL5 / 4P TL-D / 4P PL-L / 4P PL-T / C / 4P BATTERY DATA


VOLTAGE CAPACITY CELL TYPE CELL SIZE (mm) QTY OF CELLS DIMENSIONS (mm) WEIGHT (kg)
230 VAC -IıIı- GW CEM1 EN
SELV 50/60 Hz IP 20 Ni - Cd 850°C PCB SMD 61347-2-7
3,6 V 900 mAh AA 15 3 15 x 153±3 x 15 0,085
In accordance with EN 61347-1 and EN 61347-2-7 standards. 3,6 V 1200 mAh SC 23 3 23 x 129±3 x 23 0,150
3,6 V 1600 mAh SC 23 3 23 x 129±3 x 23 0,150
3,6 V 2500 mAh C 26 3 26 x 150±3 x 26 0,240
3,6 V 3000 mAh C 26 3 26 x 150±3 x 26 0,240
3,6 V 4000 mAh D 33 3 33 x 180±3 x 33 0,375
TECHNICAL DATA 4,8 V 1800 mAh SC 23 4 33 x 172±4 x 33 0,225
4,8 V 4000 mAh D 33 4 33 x 240±4 x 33 0,520
SUPPLY VOLTAGE : 230 VAC 50/60 Hz BATTERY CHARGING TIME : 24 h
AMBIENT TEMPERATURE (ta) : -10 °C … +50 °C EMERGENCY LUMEN FACTOR (BLF) : %7 … %20 Battery dimensions are given without holder. When the holders are added, the length will increase by +40mm and the diameter +5mm.
MAX. CASING TEMPERATURE (tc) : 70 °C PROTECTION CLASS : IP 20 Please refer to “Battery Details Table” in “Emergency Lighting Solutions Overview” section of the catalogue for further battery infor-
RATED DURATION : 1/3h INSULATION CLASS : II mation.

WIRING DIAGRAM TECHNICAL DRAWING


PRODUCT LIST
PRODUCT RATED FLUORESCENT LAMP TYPE & LAMP POWER
CODE DURATION 4-pin T8 4-pin T5 4-pin PLL 4-pin PLC
EMLUS-FLS/A 1/3h 18 W 13-14 W 11-18 W 13 W
EMLUS-FLS/B 1/3h 36 W 24 W 24-36 W 18-26 W
EMLUS-FLS/C 1/3h 58 W 21-39 W 55 W -
EMLUS-FLS/D 1/3h - 28-35-49-54-80 W - 32-42 W

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice 113
BATTERY AND MAINS DATA
EMERGENCY LIGHTING UNITS
PRODUCT BATTERY RATED MAINS POWER DIMENSIONS WEIGHT QTY
FLUORESCENT LAMP CODE CAPACITY POWER (W)* CURRENT (A)* FACTOR (PF)* (mm) (kg) in CARTON BOX

EMLUS-FLT EMLUS-FLT/AX2/1H 3,6 V / 900 mAh (1 h) 3,00 0,014 0,95 41 x 169,5 x 31,5 0,180 30
EMLUS-FLT/AX2/3H 3,6 V / 2500 mAh (3 h) 3,40 0,015 0,96 41 x 169,5 x 31,5 0,180 30
EMLUS-FLT/BX2/1H 3,6 V / 1200 mAh (1 h) 3,10 0,014 0,96 41 x 169,5 x 31,5 0,180 30
EMLUS-FLT/BX2/3H 3,6 V / 2500 mAh (3 h) 3,40 0,015 0,96 41 x 169,5 x 31,5 0,180 30
Compatible with electronic and magnetic ballast EMLUS-FLT/CX2/1H 3,6 V / 1600 mAh (1 h) 3,40 0,015 0,96 41 x 169,5 x 31,5 0,180 30
Non-maintained operation EMLUS-FLT/CX2/3H 3,6 V / 4000 mAh (3 h) 3,40 0,015 0,96 41 x 169,5 x 31,5 0,180 30
Emergency lighting function by interruption of the unswitched phase EMLUS-FLT/DX2/1H 4,8 V / 1800 mAh (1 h) 3,85 0,017 0,97 41 x 169,5 x 31,5 0,180 30
1 - 3 h duration EMLUS-FLT/DX2/3H 4,8 V / 4000 mAh (3 h) 3,85 0,017 0,97 41 x 169,5 x 31,5 0,180 30
Compatible with 4-pin fluorescent lamps
Prolonging the lamp life with warm-start * Measured under 230 V mains.
Short-circuit, open-circuit and overload protection
High-temperature Ni-Cd battery cells
Overcharge and deep discharge protection EMERGENCY LUMEN FACTOR
Polarity reversal protection for battery PRODUCT FLUORESCENT LAMP TYPE & LAMP POWER
Charge status display with green LED 4-pin T8 4-pin T5 4-pin PLL 4-pin PLC
Polycarbonate case
EMLUS-FLT/AX2 18W(%11) 13W(%18) 14W(%17) 11W(%20) 18W(%13) 13W(%20)
Simple connectable terminal block
EMLUS-FLT/BX2 36W(%8) 24W(%11) 24W(%10) 36W(%13) 18W(%20) 26W(%14)
Optional - 110 VAC compatibility
EMLUS-FLT/CX2 58W(%7) 21W(%15) 39W(%14) 55W(%10) -
EMLUS-FLT/DX2 28W(%13) 35W(%10) 49W(%10) - 32W(%13) 42W(%13)
54W(%12) 80W(%8)

Measured with 3,6 V battery under maximum operating voltage.

TL5 / 4P TL-D / 4P PL-L / 4P PL-T / C / 4P BATTERY DATA


230 VAC -IıIı- GW CEM1 EN VOLTAGE CAPACITY CELL TYPE CELL SIZE (mm) * QTY OF CELLS DIMENSIONS (mm) WEIGHT (kg)
50/60 Hz IP 20 Ni - Cd 850°C PCB SMD 61347-2-7
3,6 V 900 mAh AA 15 3 15 x 153±3 x 15 0,085
In accordance with EN 61347-1 and EN 61347-2-7 standards. 3,6 V 1200 mAh SC 23 3 23 x 129±3 x 23 0,150
3,6 V 1600 mAh SC 23 3 23 x 129±3 x 23 0,150
3,6 V 2500 mAh C 26 3 26 x 150±3 x 26 0,240
3,6 V 3000 mAh C 26 3 26 x 150±3 x 26 0,240
3,6 V 4000 mAh D 33 3 33 x 180±3 x 33 0,375
TECHNICAL DATA 4,8 V 1800 mAh SC 23 4 33 x 172±4 x 33 0,225
4,8 V 4000 mAh D 33 4 33 x 240±4 x 33 0,520
SUPPLY VOLTAGE : 230 VAC 50/60 Hz BATTERY CHARGING TIME : 24 / 48 h
AMBIENT TEMPERATURE (ta) : -10 °C … +50 °C EMERGENCY LUMEN FACTOR (BLF) : %7 … %20 Battery dimensions are given without holder. When the holders are added, the length will increase by +40mm and the diameter +5mm.
MAX. CASING TEMPERATURE (tc) : 70 °C PROTECTION CLASS : IP 20 Please refer to “Battery Details Table” in “Emergency Lighting Solutions Overview” section of the catalogue for further battery infor-
RATED DURATION : 1/3h INSULATION CLASS : II mation.

WIRING DIAGRAM TECHNICAL DRAWING


PRODUCT LIST
PRODUCT RATED FLUORESCENT LAMP TYPE & LAMP POWER
CODE DURATION 4-pin T8 4-pin T5 4-pin PLL 4-pin PLC
EMLUS-FLT/AX2 1/3h 18 W 13-14 W 11-18 W 13 W
EMLUS-FLT/BX2 1/3h 36 W 24 W 24-36 W 18-26 W
EMLUS-FLT/CX2 1/3h 58 W 21-39 W 55 W -
EMLUS-FLT/DX2 1/3h - 28-35-49-54-80 W - 32-42 W

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice 115
BATTERY DATA
EMERGENCY LIGHTING UNITS
HALOGEN LAMP VOLTAGE CAPACITY DIMENSIONS
(mm)
WEIGHT
(kg)

EMLUS-1250 12 V 7000 mAh 65 x 150 x 95 2,150

* Seal lead-acid battery is used.

Compatible with 12V halogen lamps


Compatible with all dimmable and non-dimmable,
constant current control gears
Non-maintained operation
Emergency lighting function by interruption of the unswitched phase
1 - 3 h duration
WIRING DIAGRAM TECHNICAL DRAWING
Short-circuit, open-circuit and overload protection
Seal lead-acid battery
Overcharge and deep discharge protection
Charge status display with green LED
Polycarbonate case
Simple connectable terminal block
Optional - 110 VAC compatibility

HALOGEN

230 VAC GW CEM1 EN


SELV 50/60 Hz IP 20 850°C PCB SMD 61347-2-7

In accordance with EN 61347-1 and EN 61347-2-7 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz BATTERY TYPE : 12 V Lead-Acid
AMBIENT TEMPERATURE (ta) : -10 °C … +50 °C EMERGENCY LUMEN FACTOR (BLF) : %100
MAX. CASING TEMPERATURE (tc) : 70 °C MAX. OUTPUT POWER : 12 V - 50 W
RATED DURATION : 1/3h PROTECTION CLASS : IP 20
BATTERY CHARGING TIME : 48 / 96 h INSULATION CLASS : II

PRODUCT LIST
PRODUCT BATTERY RATED MAINS POWER DIMENSIONS WEIGHT QTY
CODE CAPACITY POWER (W)* CURRENT (A)* FACTOR (PF)* (mm) (kg) in CARTON BOX

12 V / 7000 mAh 0,006 - 0,070 0,47 78 x 123 x 36 0,150 25


EMLUS-1250/1H 0,95 - 12,60
(1 h)
2*12 V / 7000 mAh 0,006 - 0,070 0,47 78 x 123 x 36 0,150 25
EMLUS-1250/3H 0,95 - 12,60
(3 h)

* Measured under 230 V mains.


** Maximum values are measured with discharged batteries and values are minimum measured with full-charged batteries.

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice 117
SELF-CONTAINED PRODUCTS

EMERGENCY EXIT
LUMINAIRES
Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 119
PRODUCT LIST
EMERGENCY EXIT LUMINAIRES - LED PRODUCT
CODE
RATED
DURATION
OPERATING
MODE*
LIGHT
SOURCE
ROUTING
MODE
TYPE OF
MOUNTING
TUNA M BYAL-M08-CY/SU 3h Maintained 8 x SMD LED Double-sided Surface Mounted - Plastic Hanger
BYAL-M08-CY/SUMA 3h Maintained 8 x SMD LED Double-sided Surface Mounted –Steel Wire
BYAL-M08-CY/MT 3h Maintained 8 x SMD LED Double-sided Surface Mounted - Metal Hanger
BYAL-M08-CY/SA 3h Maintained 8 x SMD LED Double-sided Recessed Mounted
Single- or double-sided
Anodized aluminum case * Maintained: Lights on mains and stays alight in case of the mains failure.
Polycarbonate side cover and hanger
SMD LED application
Charge and battery capacity status display with green LEDs
Test switch MAINS DATA
High-temperature Ni-Cd battery cells
Overcharge and deep discharge protection PRODUCT RATED MAINS POWER DIMENSIONS WEIGHT QTY
CODE POWER (W)* CURRENT (A)* FACTOR (PF)* (mm) (kg) in CARTON BOX
Transparent plexiglas with screen printed
Side lighting BYAL-M08-CY/SU 4,87 0,035 0,61 40 x 274 x 195 0,665 1
Ceiling mounted, ceiling recessed or wall mounted BYAL-M08-CY/SUMA 4,87 0,035 0,61 40 x 274 x 195 0,885 1
Optional - 110 VAC compatibility BYAL-M08-CY/MT 4,87 0,035 0,61 40 x 274 x 195 0,745 1
Optional - Metal hanger, hook or steel wire BYAL-M08-CY/SA 4,87 0,035 0,61 102 x 342 x 195 1,220 1
Optional - Central battery system application
* Measured under 230 V mains.

RECESSED MOUNTING HOLE SIZE WIRING DIAGRAM

Please refer to “Pictogram Table” in Emergency Exit Luminaries Overview section of the catalogue for alternatives.

230 VAC 41 GW CEM1 -IıIı- EN


SELV 50/60 Hz IP 20 ALU 850°C PCB SMD Ni - Cd 60598-2-22

In accordance with EN 60598-1, EN 60598-2-22 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50 / 60 Hz SIGN DIMENSIONS : 140 x 265 mm
AMBIENT TEMPERATURE (ta) : 0 °C … +40 °C VIEWING DISTANCE : 28 m TECHNICAL DRAWING / SURFACE MOUNTED TECHNICAL DRAWING / RECESSED MOUNTED
RATED DURATION : 3h PROTECTION CLASS : IP 20
BATTERY CHARGING TIME : 24 h INSULATION CLASS : I
BATARYA TİPİ: 3,6 V Ni-Cd

CONTROL PANEL
STATE: Charge Status LED . Indicates charging process of the battery.
TEST: Test Button. Enables testing the product without mains cuts.

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 121
PRODUCT LIST
EMERGENCY EXIT LUMINAIRES - LED PRODUCT
CODE
RATED
DURATION
OPERATING
MODE*
LIGHT
SOURCE
ROUTING
MODE
TYPE OF
MOUNTING
TUNA L BYAL-L08-CY/SU 3h Maintained 10 x SMD LED Double-sided Surface Mounted - Plastic Hanger
BYAL-L08-CY/SUMA 3h Maintained 10 x SMD LED Double-sided Surface Mounted –Steel Wire
BYAL-L08-CY/MT 3h Maintained 10 x SMD LED Double-sided Surface Mounted – Metal Hanger
BYAL-L08-CY/SA 3h Maintained 10 x SMD LED Double-sided Recessed Mounted
Single- or double-sided
* Maintained: Lights on mains and stays alight in case of the mains failure.
Anodized aluminum case
Polycarbonate side cover and hanger
SMD LED application
Charge and battery capacity status display with green LEDs
Test switch MAINS DATA
High-temperature Ni-Cd battery cells
Overcharge and deep discharge protection PRODUCT RATED MAINS POWER DIMENSIONS WEIGHT QTY
CODE POWER (W)* CURRENT (A)* FACTOR (PF)* (mm) (kg) in CARTON BOX
Transparent plexiglas with screen printed
Side lighting BYAL-L08-CY/SU 4,87 0,035 0,61 40 x 304 x 235 0,700 1
Ceiling mounted, ceiling recessed or wall mounted BYAL-L08-CY/SUMA 4,87 0,035 0,61 40 x 304 x 235 0,700 1
Optional - 110 VAC compatibility BYAL-L08-CY/MT 4,87 0,035 0,61 40 x 304 x 235 0,700 1
Optional - Metal hanger, hook or steel wire BYAL-L08-CY/SA 4,87 0,035 0,61 102 x 372 x 235 1,255 1

* Measured under 230 V mains.

RECESSED MOUNTING HOLE SIZE WIRING DIAGRAM

Please refer to “Pictogram Table” in Emergency Exit Luminaries Overview section of the catalogue for alternatives.

230 VAC 41 GW CEM1 -IıIı- EN


SELV 50/60 Hz IP 20 ALU 850°C PCB SMD Ni - Cd 60598-2-22

In accordance with EN 60598-1, EN 60598-2-22 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz SIGN DIMENSIONS : 180 x 299 mm
AMBIENT TEMPERATURE (ta) : 0 °C … +40 °C VIEWING DISTANCE : 36 m TECHNICAL DRAWING / SURFACE MOUNTED TECHNICAL DRAWING / RECESSED MOUNTED
RATED DURATION : 3h PROTECTION CLASS : IP 20
BATTERY CHARGING TIME : 24 h INSULATION CLASS : I
BATARYA TİPİ: 3,6 V Ni-Cd

CONTROL PANEL
STATE: Charge Status LED . Indicates charging process of the battery.
TEST: Test Button. Enables testing the product without mains cuts.

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 123
PRODUCT LIST
EMERGENCY EXIT LUMINAIRES - LED PRODUCT
CODE
RATED
DURATION
OPERATING
MODE*
LIGHT
SOURCE
ROUTING
MODE
TYPE OF
MOUNTING
ÇUPRA BYAL05-TY/SU 3h Maintained 4 x SMD LED Single-sided Surface Mounted - Plastic Hanger
BYAL05-TY/SUMA 3h Maintained 4 x SMD LED Single-sided Surface Mounted –Steel Wire
BYAL05-TY/MT 3h Maintained 4 x SMD LED Single-sided Surface Mounted - Metal Hanger
BYAL05-TY/SA 3h Maintained 4 x SMD LED Single-sided Recessed Mounted
Single- or double-sided
Anodized aluminum case * Maintained: Lights on mains and stays alight in case of the mains failure.
Polycarbonate side cover and hanger
SMD LED application
Charge and battery capacity status display with green LEDs
Test switch MAINS DATA
High-temperature Ni-Cd battery cells
PRODUCT RATED MAINS POWER DIMENSIONS WEIGHT QTY
Overcharge and deep discharge protection CODE POWER (W)* CURRENT (A)* FACTOR (PF)* (mm) (kg) in CARTON BOX
Transparent plexiglas with screen printed
Side lighting BYAL05-TY/SU 3,25 0,015 0,94 38 x 245 x 187 0,525 1
Ceiling mounted, ceiling recessed or wall mounted BYAL05-TY/SUMA 3,25 0,015 0,94 38 x 245 x 187 0,745 1
Optional - 110 VAC compatibility BYAL05-TY/MT 3,25 0,015 0,94 38 x 245 x 187 0,605 1
Optional - Metal hanger, hook or steel wire BYAL05-TY/SA 3,25 0,015 0,94 102 x 312 x 187 0,910 1
* Measured under 230 V mains.

RECESSED MOUNTING HOLE SIZE WIRING DIAGRAM

Please refer to “Pictogram Table” in Emergency Exit Luminaries Overview section of the catalogue for alternatives.

230 VAC 41 GW CEM1 -IıIı- EN


SELV 50/60 Hz IP 20 ALU 850°C PCB SMD Ni - Cd 60598-2-22

In accordance with EN 60598-1, EN 60598-2-22 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz SIGN DIMENSIONS : 130 x 235 mm
AMBIENT TEMPERATURE (ta) : 0 °C … +40 °C VIEWING DISTANCE : 26 m TECHNICAL DRAWING / SURFACE MOUNTED TECHNICAL DRAWING / RECESSED MOUNTED
RATED DURATION : 3h PROTECTION CLASS : IP 20
BATTERY CHARGING TIME : 24 h INSULATION CLASS : I
BATARYA TİPİ: 3,6 V Ni-Cd

CONTROL PANEL
STATE: Charge Status LED . Indicates charging process of the battery.
TEST: Test Button. Enables testing the product without mains cuts.

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 125
PRODUCT LIST
EMERGENCY EXIT LUMINAIRES - LED PRODUCT
CODE
RATED
DURATION
OPERATING
MODE*
LIGHT
SOURCE
ROUTING
MODE
TYPE OF
MOUNTING
MERCAN LED
BYAL04-S/LED/CY 3h Maintained 12 x SMD LED Double-sided Surface Mounted - Plastic Hanger
BYAL04-S/LED/CY/MT 3h Maintained 12 x SMD LED Double-sided Surface Mounted - Metal Hanger
BYAL04-S/LED/TY 3h Maintained 12 x SMD LED Single-sided Surface Mounted - Plastic Hanger
BYAL04-S/LED/TY/MT 3h Maintained 12 x SMD LED Single-sided Surface Mounted - Metal Tij
Single- or double-sided
Anodized aluminum case * Maintained: Lights on mains and stays alight in case of the mains failure.
Polycarbonate side cover and hanger
SMD LED application
Charge and battery capacity status display with green LEDs
Test switch
High-temperature Ni-Cd battery cells
MAINS DATA
Overcharge and deep discharge protection PRODUCT RATED MAINS POWER DIMENSIONS WEIGHT QTY
White acrylic plate CODE POWER (W)* CURRENT (A)* FACTOR (PF)* (mm) (kg) in CARTON BOX
Back lighting
BYAL04-S/LED/CY/3H 5,0 0,034 0,64 335 x 63 x 220 1,250 1
Ceiling mounted or wall mounted
BYAL04-S/LED/CY/MT/3H 5,0 0,034 0,64 335 x 63 x 220 1,330 1
Optional - 110 VAC compatibility
BYAL04-S/LED/TY/3H 5,0 0,034 0,64 335 x 63 x 220 1,385 1
Optional - Metal hanger, hook or steel wire
BYAL04-S/LED/TY/MT/3H 5,0 0,034 0,64 335 x 63 x 220 1,365 1

* Measured under 230 V mains.

WIRING DIAGRAM TECHNICAL DRAWING


Please refer to “Pictogram Table” in Emergency Exit Luminaries Overview section of the catalogue for alternatives.

230 VAC 41 GW CEM1 -IıIı- EN


SELV 50/60 Hz IP 20 ALU 850°C PCB SMD Ni - Cd 60598-2-22

In accordance with EN 60598-1, EN 60598-2-22 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50 / 60 Hz SIGN DIMENSIONS : 130 x 335 mm
AMBIENT TEMPERATURE (ta) : 0 °C … +40 °C VIEWING DISTANCE : 26 m
RATED DURATION : 3h PROTECTION CLASS : IP 20
BATTERY CHARGING TIME : 24 h INSULATION CLASS : I
BATARYA TİPİ: 3,6 V Ni-Cd

CONTROL PANEL
STATE: Charge Status LED . Indicates charging process of the battery.
TEST: Test Button. Enables testing the product without mains cuts.

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 127
MAINS DATA
EMERGENCY EXIT LUMINAIRES - LED PRODUCT
CODE
RATED
POWER (W)*
MAINS
CURRENT (A)*
DIMENSIONS
(mm)
WEIGHT
(kg)
QTY
in CARTON BOX
TRAKONYA
BYPL05-CY/SU 1,2 0,155 40x264x255 0,330 1
BYPL05-CY/SA 1,2 0,155 92x325x210 0,700 1

* Measured under 230 V mains.


Single- or double-sided
Polycarbonate case and hanger
SMD LED application
Charge and battery capacity status display with green LED RECESSED MOUNTING HOLE SIZE WIRING DIAGRAM
High-temperature Ni-Cd battery cells
Overcharge and deep discharge protection
Transparent plexiglas with screen printed
Side lighting
Ceiling mounted, ceiling recessed or wall mounted

Please refer to “Pictogram Table” in Emergency Exit Luminaries Overview section of the catalogue for alternatives.

TECHNICAL DRAWING / SURFACE MOUNTED TECHNICAL DRAWING / RECESSED MOUNTED

230 VAC CEM1 -IıIı- EN


SELV 50/60 Hz IP 20 PCB SMD Ni - Cd 60598-2-22

In accordance with EN 60598-1, EN 60598-2-22 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz SIGN DIMENSIONS : 150 x 264 mm
AMBIENT TEMPERATURE (ta) : 0 °C … +40 °C VIEWING DISTANCE : 30 m
RATED DURATION : 3h PROTECTION CLASS : IP 20
BATTERY CHARGING TIME : 24 h INSULATION CLASS : II
BATARYA TİPİ: 1,2 V Ni-Cd

PRODUCT LIST
PRODUCT RATED OPERATING LIGHT ROUTING TYPE OF
CODE DURATION MODE* SOURCE MODE MOUNTING

BYPL05-CY/SU 3h Maintained 9 x SMD LED Double-sided Surface Mounted - Plastic Hanger


BYPL05-CY/SA 3h Maintained 9 x SMD LED Double-sided Recessed Mounted

* Maintained: Lights on mains and stays alight in case of the mains failure.

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 129
EMERGENCY EXIT LUMINAIRES - LED PRODUCT LIST
LAPİN LED PRODUCT RATED OPERATING LIGHT ROUTING TYPE OF
CODE DURATION MODE* SOURCE MODE MOUNTING
LİPSOS LED BYAL06-S/LED 3h Maintained 12 x SMD LED Double-sided (Lapin) Surface Mounted - Plastic Hanger
BYAL06-S/LED/MT 3h Maintained 12 x SMD LED Double-sided (Lapin) Surface Mounted - Metal Hanger
BYAL06-S/LED/SA 3h Maintained 12 x SMD LED Double-sided (Lapin) Recessed Mounted
BYAL07-S/LED 3h Maintained 12 x SMD LED Single-sided (Lipsos) Surface Mounted - Plastic Hanger
Single- or double-sided BYAL07-S/LED/MT 12 x SMD LED Single-sided (Lipsos) Surface Mounted - Metal Hanger
3h Maintained
Anodized aluminum case BYAL07-S/LED/SA 12 x SMD LED Single-sided (Lipsos) Recessed Mounted
3h Maintained
Polycarbonate side cover and hanger
SMD LED application * Maintained : Lights on mains and stays alight in case of the mains failure.
Charge status display with green LED
Test switch
High-temperature Ni-Cd battery cells
Overcharge and deep discharge protection MAINS DATA
White acrylic plate
Back lighting PRODUCT RATED MAINS POWER DIMENSIONS WEIGHT QTY
Ceiling mounted, ceiling recessed or wall mounted CODE POWER (W)* CURRENT (A)* FACTOR (PF)* (mm) (kg) in CARTON BOX
Optional - 110 VAC compatibility
BYAL06-S/LED 5,0 0,034 0,64 365 x 43 x 168 0,770 1
Optional - Metal hanger, hook or steel wire
BYAL06-S/LED/MT 5,0 0,034 0,64 365 x 43 x 168 0,850 1
BYAL06-S/LED/SA 5,0 0,034 0,64 425 x 43 x 186 0,900 1
BYAL07-S/LED 5,0 0,034 0,64 365 x 43 x 168 0,915 1
BYAL07-S/LED/MT 5,0 0,034 0,64 365 x 43 x 168 0,995 1
BYAL07-S/LED/SA 5,0 0,034 0,64 425 x 43 x 186 1,045 1

* Measured under 230 V mains.

Please refer to “Pictogram Table” in Emergency Exit Luminaries Overview section of the catalogue for alternatives.
WIRING DIAGRAM

230 VAC 41 GW CEM1 -IıIı- EN


SELV 50/60 Hz IP 20 ALU 850 OC SMD Ni - Cd 60598-2-22
PCB

In accordance with EN 60598-1, EN 60598-2-22 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50 / 60 Hz SIGN DIMENSIONS : 140 x 335 mm
AMBIENT TEMPERATURE (ta) : 0 °C … +40 °C VIEWING DISTANCE : 28 m
RATED DURATION : 3h PROTECTION CLASS : IP 20
BATTERY CHARGING TIME : 24 h INSULATION CLASS : I
BATARYA TİPİ: 3,6 V Ni-Cd

TECHNICAL DRAWING / SURFACE MOUNTED TECHNICAL DRAWING / RECESSED MOUNTED

CONTROL PANEL
STATE: Charge Status LED . Indicates charging process of the battery.
TEST: Test Button. Enables testing the product without mains cuts.

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 131
EMERGENCY EXIT LUMINAIRES - LED PRODUCT LIST
LAPİN XL LED PRODUCT RATED OPERATING LIGHT ROUTING TYPE OF
CODE DURATION MODE* SOURCE MODE MOUNTING
LİPSOS XL LED BYAL-XL06-LED-S 3h Maintained 24 x SMD LED Double-sided (Lapin) Surface Mounted - Hook Hanger
BYAL-XL07-LED-S 3h Maintained 24 x SMD LED Single-sided (Lipsos) Wall Mounted

* Maintained : Lights on mains and stays alight in case of the mains failure.
Single- or double-sided
Anodized aluminum case
Polycarbonate side cover and hanger
SMD LED application
Charge status display with green LED
Test switch
High-temperature Ni-Cd battery cells
Overcharge and deep discharge protection MAINS DATA
White acrylic plate
Back lighting PRODUCT RATED MAINS POWER DIMENSIONS WEIGHT QTY
Ceiling mounted, ceiling recessed or wall mounted CODE POWER (W)* CURRENT (A)* FACTOR (PF)* (mm) (kg) in CARTON BOX
Optional - 110 VAC compatibility BYAL-XL06-LED-S/3H 5,85 0,040 0,64 630 x 43 x 430 2,400 1
Optional - Metal hanger, hook or steel wire BYAL-XL07-LED-S/3H 5,85 0,040 0,64 630 x 43 x 430 2,400 1

* Measured under 230 V mains.

Please refer to “Pictogram Table” in Emergency Exit Luminaries Overview section of the catalogue for alternatives. WIRING DIAGRAM TECHNICAL DRAWING

230 VAC 41 GW CEM1 -IıIı- EN


SELV 50/60 Hz IP 20 ALU 850 OC SMD Ni - Cd 60598-2-22
PCB

In accordance with EN 60598-1, EN 60598-2-22 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50 / 60 Hz SIGN DIMENSIONS : 400 x 600 mm
AMBIENT TEMPERATURE (ta) : 0 °C … +40 °C VIEWING DISTANCE : 80 m
RATED DURATION : 3h PROTECTION CLASS : IP 20
BATTERY CHARGING TIME : 24 h INSULATION CLASS : I
BATARYA TİPİ: 3,6 V Ni-Cd

CONTROL PANEL
STATE: Charge Status LED . Indicates charging process of the battery.
TEST: Test Button. Enables testing the product without mains cuts.

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 133
PRODUCT LIST
EMERGENCY EXIT LUMINAIRES - LED PRODUCT
CODE
RATED
DURATION
OPERATING
MODE*
LIGHT
SOURCE
ROUTING
MODE
TYPE OF
MOUNTING
ORFOZ
BYPL02-S-XLED2 3h Main- 20 x SMD LED Double-sided Surface Mounted
tained
* Maintained : Lights on mains and stays alight in case of the mains failure.

Indoor and outdoor use


Polycarbonate case and glass
Moisture-proof
SMD LED application
High energy saving
Long life-time (50.000 hours) MAINS DATA
Emergency lighting function by interruption of the unswitched phase
PRODUCT RATED MAINS POWER DIMENSIONS WEIGHT QTY
Emergency lighting function in case of low-voltage CODE POWER (W)* CURRENT (A)* FACTOR (PF)* (mm) (kg) in CARTON BOX
3 hours duration in case of emergency
Charge status display with green LED BYPL02-S-XLED2 4,5 0,034 0,58 122 x 360 x 205 1,025 1
Test switch * Measured under 230 V mains.
High-temperature Ni-Cd battery cells
Overcharge and deep discharge protection
Ceiling mounted
Optional - 110 VAC compatibility

WIRING DIAGRAM TECHNICAL DRAWING

Please refer to “Pictogram Table” in Emergency Exit Luminaries Overview section of the catalogue for alternatives.

230 VAC GW FR4 -IıIı- EN


SELV 50/60 Hz IP 65 850°C PCB SMD Ni - Cd 60598-2-22

In accordance with EN 60598-1, EN 60598-2-22 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz SIGN DIMENSIONS : 140 x 300 mm
AMBIENT TEMPERATURE (ta) : -5 °C … +40 °C VIEWING DISTANCE : 28 m
RATED DURATION : 3h PROTECTION CLASS : IP 65
BATTERY CHARGING TIME : 24 h INSULATION CLASS : II
BATARYA TİPİ: 3,6 V Ni-Cd

CONTROL PANEL
STATE: Charge Status LED . Indicates charging process of the battery.
TEST: Test Button. Enables testing the product without mains cuts.

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 135
PRODUCT LIST
EMERGENCY EXIT LUMINAIRES - LED PRODUCT
CODE
RATED
DURATION
OPERATING
MODE*
LIGHT
SOURCE
ROUTING
MODE
TYPE OF
MOUNTING
SOMON-XLED2
BYPL06-S-XLED2 3h Maintained 20 x SMD LED Single-sided Surface Mounted

* Maintained : Lights on mains and stays alight in case of the mains failure.

Indoor and outdoor use


Polycarbonate case and glass
Moisture-proof
SMD LED application
High energy saving
Long life-time (50.000 hours) MAINS DATA
Emergency lighting function by interruption of the unswitched phase
PRODUCT RATED MAINS POWER DIMENSIONS WEIGHT QTY
Emergency lighting function in case of low-voltage CODE POWER (W)* CURRENT (A)* FACTOR (PF)* (mm) (kg) in CARTON BOX
3 hours duration in case of emergency
Charge status display with green LED BYPL06-S-XLED2 4.51 0,034 0,58 108 x 341 x 60 0,630 1
Test switch * Measured under 230 V mains.
High-temperature Ni-Cd battery cells
Overcharge and deep discharge protection
Wall mounted
Optional - 110 VAC compatibility

WIRING DIAGRAM TECHNICAL DRAWING

Please refer to “Pictogram Table” in Emergency Exit Luminaries Overview section of the catalogue for alternatives.

230 VAC GW FR4 -IıIı- EN


SELV 50/60 Hz IP 65 850°C PCB SMD Ni - Cd 60598-2-22

In accordance with EN 60598-1, EN 60598-2-22 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz SIGN DIMENSIONS : 108 x 341 mm
AMBIENT TEMPERATURE (ta) : -5 °C … +40 °C VIEWING DISTANCE : 21 m
RATED DURATION : 3h PROTECTION CLASS : IP 65
BATTERY CHARGING TIME : 24 h INSULATION CLASS : II
BATARYA TİPİ: 3,6 V Ni-Cd

CONTROL PANEL
STATE: Charge Status LED . Indicates charging process of the battery.
TEST: Test Button. Enables testing the product without mains cuts.

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 137
PRODUCT LIST
EMERGENCY EXIT LUMINAIRES - LED PRODUCT
CODE
RATED
DURATION
OPERATING
MODE*
LIGHT
SOURCE
ROUTING
MODE
TYPE OF
MOUNTING
SARGOZ LED
BYPL04-S-LED 3h Maintained 20 x SMD LED Single-sided Surface Mounted

* Maintained : Lights on mains and stays alight in case of the mains failure.

Indoor use
Polycarbonate case and glass
SMD LED application
High energy saving
Long life-time (50.000 hours)
Emergency lighting function by interruption of the unswitched phase MAINS DATA
3 hours duration in case of emergency
PRODUCT RATED MAINS DIMENSIONS WEIGHT QTY
Charge status display with green LED CODE POWER (W)* CURRENT (A)* (mm) (kg) in CARTON BOX
Test switch
High-temperature Ni-Cd battery cells BYPL04-S-LED 1,15 0,210 100 x 300 x 42 0,400 1
Overcharge and deep discharge protection * Measured under 230 V mains.
Ceiling or wall mounted

WIRING DIAGRAM TECHNICAL DRAWING

Please refer to “Pictogram Table” in Emergency Exit Luminaries Overview section of the catalogue for alternatives.

230 VAC GW FR4 -IıIı- EN


SELV 50/60 Hz IP 20 850°C PCB SMD Ni - Cd 60598-2-22

In accordance with EN 60598-1, EN 60598-2-22 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz SIGN DIMENSIONS : 100 x 300 mm
AMBIENT TEMPERATURE (ta) : 0 °C … +40 °C VIEWING DISTANCE : 20 m
RATED DURATION : 3h PROTECTION CLASS : IP 20
BATTERY CHARGING TIME : 24 h INSULATION CLASS : II
BATARYA TİPİ: 2,4 V Ni-Cd

CONTROL PANEL
STATE: Charge Status LED . Indicates charging process of the battery.
TEST: Test Button. Enables testing the product without mains cuts.

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice. 139
SELF-CONTAINED PRODUCTS

EMERGENCY
LIGHTING LUMINAIRES
Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice 141
EMERGENCY LIGHTING MAINS DATA
LUMINAIRES – LED PRODUCT
CODE
BATTERY
CAPACITY
RATED
POWER (W) *
MAINS
CURRENT (A) *
POWER
FACTOR (PF)*
DIMENSIONS
(mm)
WEIGHT
(kg)
QTY
in CARTON BOX
RİNA AA104-RINA/1W 3,6V / 900mAh 1,20 0,017 0,31 Spot: 100 x 100 x 25 0,065 1
Unit: 41 x 169,5 x 31,5 0,080
Battery: 39 x 221 x 34 0,100
AA104-RINA/2W 3,6V / 1800mAh 1,75 0,020 0,39 Spot: 100 x 100 x 25 0,065 1
SMD power LED application
Unit: 41 x 169,5 x 31,5 0,080
Long life-time (50.000 hours)
Battery: 39 x 221 x 34 0,165
Emergency lighting function by interruption of the unswitched phase
AA104-RINA/3W 3,6V / 3000mAh 2,40 0,025 0,43 Spot: 100 x 100 x 25 0,065 1
Emergency lighting function in case of low-voltage
Unit: 41 x 169,5 x 31,5 0,080
3 hours duration in case of emergency
Battery: 39 x 221 x 34 0,255
Status display with green LED
AA104-RINA/4W 3,6V / 4000mAh 3,60 0,030 0,51 Spot: 100 x 100 x 25 0,065 1
Test switch
Unit: 41 x 169,5 x 31,5 0,080
High-temperature Ni-Cd battery cells
Battery: 39 x 221 x 34 0,390
Overcharge and deep discharge protection
Polycarbonate case * Measured under 230 V mains.
Recessed mounted
Asymmetric lens
Optional - Symmetric lens application
Optional - Surface mounted application
BATTERY DATA
VOLTAGE CAPACITY CELL TYPE CELL SIZE (mm) QTY OF CELLS DIMENSIONS (mm) WEIGHT
(kg)

3,6V 900mAh AA 15 3 15 x 153±3 x 15 0,085


3,6V 1800mAh SC 23 3 23 x 129±3 x 23 0,150
3,6V 3000mAh C 26 3 26 x 150±3 x 26 0,240
3,6V 4000mAh D 33 3 33 x 180±3 x 33 0,375

LED SPOT

230 VAC FR4 -IıIı- EN


SELV IP 20 GW CEM3 SMD
50/60 Hz 850°C Ni - Cd 60598-2-22
PCB
WIRING DIAGRAM RECESSED MOUNTING HOLE SIZE
In accordance with EN 60598-1, EN 60598-2-22 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz LIGHT SOURCE : Power LED
AMBIENT TEMPERATURE (ta) : 0 °C … +40 °C DIFFUSER : Symmetric / Asymmetric LENS
RATED DURATION : 3h PROTECTION CLASS : IP 20
BATTERY CHARGING TIME : 24 h INSULATION CLASS : II
BATTERY TYPE : 3,6V Ni-Cd

PRODUCT LIST
PRODUCT RATED OPERATING LIGHT LIGHT INTENSITY on TYPE of BATTERY
CODE DURATION MODE* SOURCE ENERGY/EMERGENCY MOUNTING CHARGING TIME

AA104-RINA/1W 3h Non-Maintained Power LED - / 105 lm Recessed / Surface Mounted 24 h


AA104-RINA/2W 3h Non-Maintained Power LED - / 205 lm Recessed / Surface Mounted 24 h
AA104-RINA/3W 3h Non-Maintained Power LED - / 305 lm Recessed / Surface Mounted 24 h
AA104-RINA/4W 3h Non-Maintained Power LED - / 405 lm Recessed / Surface Mounted 24 h

* Non-maintained : Lights in case of the mains failure.

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice 143
EMERGENCY LIGHTING PHOTOMETRY DATA (3W)
LUMINAIRES – LED Open Area (Anti-Panic) Lighting (for min. 0,5 lux)
(Symmetric Lens)
Escape Route Lighting (for min. 1 lux)
(Asymmetric Lens)

RİNA
Mounting Distance Between Distance Between Mounting Distance Between Distance Between
Height (m) Luminaire and Wall (m) Luminaires (m) Height (m) Luminaire and Wall (m) Luminaires (m)
TECHNICAL DRAWING (LED SPOT) TECHNICAL DRAWING (EMERGENCY UNIT)
2,00 3,00 5,50 2,00 6,50 11,50
2,50 4,00 7,50 2,50 8,00 15,50
3,00 4,50 8,50 3,00 9,50 18,50
3,50 4,50 10,00 3,50 10,50 21,50
4,00 5,00 11,00 4,00 11,00 24,00

LIGHT DISTRIBUTION CURVE (SYMMETRIC LENS)

TECHNICAL DRAWING (BATTERY BOX)

LIGHT DISTRIBUTION CURVE (ASYMMETRIC LENS)

PHOTOMETRY DATA (1W)


Open Area (Anti-Panic) Lighting (for min. 0,5 lux) Escape Route Lighting (for min. 1 lux)
(Symmetric Lens) (Asymmetric Lens)

Mounting Distance Between Distance Between Mounting Distance Between Distance Between
Height (m) Luminaire and Wall (m) Luminaires (m) Height (m) Luminaire and Wall (m) Luminaires (m)
2,00 2,00 4,00 2,00 5,50 10,50
2,50 2,50 5,00 2,50 7,00 13,50
3,00 2,50 5,00 3,00 6,50 16,00
3,50 3,00 6,00 3,50 6,00 16,50
4,00 3,00 6,50 4,00 3,50 11,50

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice 145
EMERGENCY LIGHTING MAINS DATA
LUMINAIRES – LED PRODUCT
CODE
BATTERY
CAPACITY
RATED
POWER (W) *
MAINS
CURRENT (A) *
POWER
FACTOR (PF)*
DIMENSIONS
(mm)
WEIGHT
(kg)
QTY
in CARTON BOX
RİNA-E AA104-RINA-E/1W 3,6V / 900mAh 1,75 0,009 0,84 Spot: 100 x 100 x 25 0,065 1
Unit: 44 x 110 x 36 0,235

AA104-RINA-E/2W 3,6V / 1200mAh 1,80 0,009 0,84 Spot: 100 x 100 x 25 0,065 1
SMD power LED application
Unit: 44 x 110 x 36 0,235
Long life-time (50.000 hours)
Emergency lighting function by interruption of the unswitched phase
AA104-RINA-E/3W 3,6V / 1800mAh 1,80 0,009 0,84 Spot: 100 x 100 x 25 0,065 1
Emergency lighting function in case of low-voltage
Unit: 44 x 110 x 36 0,235
3 hours duration in case of emergency
Status display with green LED
AA104-RINA-E/4W 3,6V / 2500mAh 1,80 0,009 0,84 Spot: 100 x 100 x 25 0,065 1
Test switch
Unit: 44 x 110 x 36 0,235
High-temperature Ni-Cd battery cells
Overcharge and deep discharge protection
Polycarbonate case * Measured under 230 V mains.
Recessed mounted
Asymmetric lens BATTERY DATA
Optional - Symmetric lens application
Optional - Surface mounted application VOLTAGE CAPACITY CELL TYPE CELL SIZE (mm) QTY OF CELLS DIMENSIONS (mm) WEIGHT
(kg)

3,6V 900mAh AA 15 3 15 x 153±3 x 15 0,085


3,6V 1200mAh SC 23 3 23 x 129±3 x 23 0,150
3,6V 1800mAh SC 23 3 23 x 129±3 x 23 0,150
3,6V 2500mAh C 26 3 26 x 150±3 x 26 0,240

WIRING DIAGRAM RECESSED MOUNTING HOLE SIZE


LED SPOT

230 VAC GW CEM1 -IıIı- EN


SELV 50/60 Hz IP 20 850°C CEM3 SMD Ni - Cd 60598-2-22
PCB

In accordance with EN 60598-1, EN 60598-2-22 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz LIGHT SOURCE : Power LED
AMBIENT TEMPERATURE (ta) : 0 °C … +40 °C DIFFUSER : Symmetric / Asymmetric LENS
RATED DURATION : 3h PROTECTION CLASS : IP 20
BATTERY CHARGING TIME : 24/48 h INSULATION CLASS : II
BATTERY TYPE : 3,6V Ni-Cd

TECHNICAL DRAWING (LED SPOT) TECHNICAL DRAWING (EMERGENCY UNIT)


PRODUCT LIST
PRODUCT RATED OPERATING LIGHT LIGHT INTENSITY on TYPE of BATTERY
CODE DURATION MODE* SOURCE ENERGY/EMERGENCY MOUNTING CHARGING TIME

AA104-RINA-E/1W 3h Non-Maintained Power LED - / 90 lm Recessed / Surface Mounted 24 h


AA104-RINA-E/2W 3h Non-Maintained Power LED - / 170 lm Recessed / Surface Mounted 48 h
AA104-RINA-E/3W 3h Non-Maintained Power LED - / 260 lm Recessed / Surface Mounted 48 h
AA104-RINA-E/4W 3h Non-Maintained Power LED - / 350 lm Recessed / Surface Mounted 48 h

* Non-maintained : Lights in case of the mains failure.

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice 147
EMERGENCY LIGHTING MAINS DATA
LUMINAIRES – LED PRODUCT
CODE
RATED
POWER (W)*
MAINS
CURRENT (A)*
POWER
FACTOR (PF)*
DIMENSIONS
(mm)
WEIGHT
(kg)
QTY
in CARTON BOX
SOMON XLED2 BYPL06-S-XLED2/1W 4.51 0,033 0,58 108 x 341 x 60 0,630 1
BYPL06-A-XLED2/1W 1.21 0,017 0,31 108 x 341 x 60 0,630 1
BYPL06-A-XLED2/2W 1.73 0,019 0,39 108 x 341 x 60 0,690 1
BYPL06-A-XLED2/3W 2.38 0,024 0,43 108 x 341 x 60 0,780 1
Indoor and outdoor use BYPL06-A-XLED2/4W 3.24 0,028 0,49 108 x 341 x 60 0,850 1
Polycarbonate case and glass
Moisture-proof * Measured under 230 V mains.
SMD LED application
High energy saving
Long life-time (50.000 hours)
Emergency lighting function by interruption of the unswitched phase
Emergency lighting function in case of low-voltage
3 hours duration in case of emergency
Charge status display with green LED
Test switch
Remote control and test with DALI interface WIRING DIAGRAM RECESSED MOUNTING HOLE SIZE
High-temperature Ni-Cd battery cells
Overcharge and deep discharge protection
Ceiling mounted, ceiling recessed or wall mounted
Optional - 110 VAC compatibility

230 VAC GW FR4 -IıIı- EN


SELV 50/60 Hz IP 65 850°C PCB SMD Ni - Cd 60598-2-22

In accordance with EN 60598-1, EN 60598-2-22 standards.

TECHNICAL DATA TECHNICAL DRAWING / RECESSED


SUPPLY VOLTAGE : 230 VAC 50/60 Hz LIGHT SOURCE : SMD LED
MOUNTED
AMBIENT TEMPERATURE (ta) : -5°C … +40°C DIFFUSER : Polycarbonate
RATED DURATION : 1/3h PROTECTION CLASS : Glass
BATTERY CHARGING TIME : 24 h INSULATION CLASS : IP 65
BATTERY TYPE : 3,6 V Ni-Cd II

PRODUCT LIST
PRODUCT RATED OPERATING LIGHT LIGHT INTENSITY on ROUTING BATTERY
CODE DURATION MODE* SOURCE ENERGY/EMERGENCY MODE CHARGING TIME

BYPL06-S-XLED2/1W 3h Maintained 20 x SMD LED 115 lm / 115 lm Recessed / Surface Mounted 24 h


BYPL06-A-XLED2/1W 3h Non-Maintained 20 x SMD LED - / 115 lm Recessed / Surface Mounted 24 h
BYPL06-A-XLED2/2W 3h Non-Maintained 20 x SMD LED - / 230 lm Recessed / Surface Mounted 24 h
BYPL06-A-XLED2/3W 3h Non-Maintained 20 x SMD LED - / 350 lm Recessed / Surface Mounted 24 h
BYPL06-A-XLED2/4W 3h Non-Maintained 20 x SMD LED - / 450 lm Recessed / Surface Mounted 24 h

* Maintained: Lights on mains and stays alight in case of the mains failure.

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice 149
EMERGENCY LIGHTING PHOTOMETRY DATA (3W)
LUMINAIRES – LED
Open Area (Anti-Panic) Lighting Escape Route Lighting
(for min. 0,5 lux) (for min. 1 lux)

SOMON XLED2
Mounting Distance Between Distance Between Mounting Distance Between Distance Between
Height (m) Luminaire and Wall (m) Luminaires (m) Height (m) Luminaire and Wall (m) Luminaires (m)
TECHNICAL DRAWING / SURFACE MOUNTED 2,00 3,00 5,50 2,00 3,00 5,75
2,50 3,50 6,75 2,50 3,50 7,00
3,00 4,00 7,75 3,00 4,00 7,75
3,50 4,25 8,50 3,50 4,25 8,50
4,00 4,50 9,25 4,00 4,25 9,25

LIGHT DISTRIBUTION CURVE

PHOTOMETRY DATA (1W)


Open Area (Anti-Panic) Lighting Escape Route Lighting
(for min. 0,5 lux) (for min. 1 lux)

Mounting Distance Between Distance Between Mounting Distance Between Distance Between
Height (m) Luminaire and Wall (m) Luminaires (m) Height (m) Luminaire and Wall (m) Luminaires (m)
2,00 2,00 3,00 2,00 2,00 3,50
2,50 2,25 4,00 2,50 2,25 4,25
3,00 2,75 4,75 3,00 2,50 4,50
3,50 2,75 5,50 3,50 2,50 5,00
4,00 2,75 6,00 4,00 2,25 5,25

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice 151
EMERGENCY LIGHTING MAINS DATA
LUMINAIRES – LED PRODUCT
CODE
RATED
POWER (W)*
MAINS
CURRENT (A)*
DIMENSIONS
(mm)
WEIGHT
(kg)
QTY
in CARTON BOX
SARGOZ LED BYPLO4-S-LED/3H 1,5 0,230 100 x 300 x 42 0,400 1
BYPLO4-A-LED/3H 0,6 0,080 100 x 300 x 42 0,350 1

* Measured under 230 V mains.


Indoor use
Polycarbonate case and glass
SMD LED application
High energy saving
Long life-time (50.000 hours)
Emergency lighting function by interruption of the unswitched phase
WIRING DIAGRAM TECHNICAL DRAWING / SURFACE MOUNTED
3 hours duration in case of emergency
Charge status display with green LED
Test switch
High-temperature Ni-Cd battery cells
Overcharge and deep discharge protection
Ceiling or wall mounted

230 VAC GW -IıIı- EN


SELV 50/60 Hz IP 20 850°C SMD Ni - Cd 60598-2-22

In accordance with EN 60598-1, EN 60598-2-22 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz LIGHT SOURCE : SMD LED
AMBIENT TEMPERATURE (ta) : 0 °C … +40 °C DIFFUSER : Polycarbonate
RATED DURATION : 3h PROTECTION CLASS : Glass
BATTERY CHARGING TIME : 24 h INSULATION CLASS : IP 20
BATTERY TYPE : 2,4 V Ni-Cd II

PRODUCT LIST
PRODUCT RATED OPERATING LIGHT LIGHT INTENSITY on ROUTING BATTERY
CODE DURATION MODE* SOURCE ENERGY/EMERGENCY MODE CHARGING TIME

BYPLO4-S-LED/3H 3h Maintained SMD LED 100 lm / 100 lm Surface Mounted 24 h


BYPLO4-A-LED/3H 3h Non-Maintained SMD LED - / 100 lm Surface Mounted 24 h

* Maintained: Lights on mains and stays alight in case of the mains failure.
Non-Maintained : Lights in case of the mains failure.

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice 153
EMERGENCY LIGHTING LUMINAIRES MAINS DATA
SENSORLIGHT – LED PRODUCT
CODE
STAND-BY RATED
RATED POWER (W)*POWER (W)*
MAINS
CURRENT (A)*
POWER
FACTOR (PF)*
DIMENSIONS
(mm)
WEIGHT
(kg)
QTY
in CARTON BOX
MANTA LED AA105-MANTA-L6D/350 - 20,5 0,125 0,72 320 x 320 x 115 1,25 1
AA105-MANTA-L6D/350/K3 3,0 24,5 0,135 0,77 320 x 320 x 115 1,70 1
AA105-MANTA-L6SD/500 0,7 30,0 0,170 0,70 320 x 320 x 115 1,30 1
AA105-MANTA-L6SD/500/K3 3,7 33,0 0,185 0,74 320 x 320 x 115 1,75 1
Indoor and outdoor use
Polycarbonate case * Measured under 230 V mains.
Soft lighting with sanded glass
Microwave radar sensor
Adjustable lighting duration WIRING DIAGRAM TECHNICAL DRAWING
Adjustable night / day working mode
High energy saving with LED lighting
Long life-time (50.000 hours)
4000 K / 6500 K Color temperature
Emergency lighting function by interruption of the unswitched phase
3 hours duration in case of emergency
Charge status display with green LED
High-temperature Ni-Cd battery cells
Overcharge and deep discharge protection
Wall and ceiling mounted
(*)Optional - Fire phase application
Optional - 110 VAC compatibility

PHOTOMETRY DATA
Open Area (Anti-Panic) Lighting Escape Route Lighting
(for min. 0,5 lux) (for min. 1 lux)

* The sensor is out-of-service when the luminaire is supplied on the fire line in case of emergency.
This feature is applied to only 9W models.

Mounting Distance Between Distance Between Mounting Distance Between Distance Between
Height (m) Luminaire and Wall (m) Luminaires (m) Height (m) Luminaire and Wall (m) Luminaires (m)
230 VAC FR4 -IıIı- EN EN 2,00 2,25 4,00 2,00 2,25 4,25
SELV 50/60 Hz IP 65 PCB SMD Ni - Cd 60598-2-22 62386
2,50 2,50 5,00 2,50 2,50 5,00
3,00 2,75 5,50 3,00 2,75 5,50
In accordance with EN 60598-1, EN 60598-2-22 standards. 3,50 3,00 6,25 3,50 2,75 5,75
TECHNICAL DATA 4,00 3,25 6,50 4,00 2,75 6,25

SUPPLY VOLTAGE : 230 VAC 50/60 Hz SENSOR TYPE : Microwave Radar Sensor
AMBIENT TEMPERATURE (ta) : -5 °C … +40 °C CASE MATERIAL : Polycarbonate
RATED DURATION : 3h LIGHT SOURCE : SMD LED LIGHT DISTRIBUTION CURVE
BATTERY CHARGING TIME : 24 h PROTECTION CLASS : IP 65
BATTERY TYPE : 3,6 V Ni-Cd INSULATION CLASS : II

PRODUCT LIST
PRODUCT RATED OPERATING LIGHT LIGHT INTENSITY on TYPE OF BATTERY
CODE DURATION MODE* SOURCE ENERGY/EMERGENCY MOUNTING CHARGING TIME

AA105-MANTA-L6D/350 - Luminaire 16W / - LED 1750lm / - Surface Mounted -


AA105-MANTA-L6D/350/K3 3h Maintained 16W / 3W LED 1750lm / 250 lm Surface Mounted 48 h
AA105-MANTA-L6SD/500 - Luminaire + Sensor 23 W / - LED 2500 lm / - Surface Mounted -
AA105-MANTA-L6SD/500/K3 3h Maintained + Sensor 23 W / 3 W LED 2500 lm / 250 lm Surface Mounted 48 h

* Luminaire: Lights just on mains.


Maintained: Lights on mains and stays alight in case of the mains failure. (With battery kit)
Sensor: Lights on mains through sensor.

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice 155
EMERGENCY LIGHTING LUMINAIRES MAINS DATA
SENSORLIGHT - LED PRODUCT
CODE
STAND-BY
RATED POWER (W)*
RATED
POWER (W)*
MAINS
CURRENT (A)*
POWER
FACTOR (PF)*
DIMENSIONS
(mm)
WEIGHT
(kg)
QTY
in CARTON BOX
VATOZ LED AA106-VATOZ-L6SD/9W 0,7 12,90 0,080 0,66 300 x 300 x 100 0,90 1
AA106-VATOZ-L6SD/9W/K 2,0 13,50 0,090 0,65 300 x 300 x 100 1,10 1

* Measured under 230 V mains.

Indoor use
Powder coated, white iron sheet case
Soft lighting with sanded glass
360° Motion sensor
Adjustable lighting duration
Adjustable night / day working mode WIRING DIAGRAM TECHNICAL DRAWING
Energy saving
Long life-time (50.000 hours)
4000 K / 6500 K Color temperature
High light intensity (1000 lm)
Emergency lighting function by interruption of the unswitched phase
3 h duration in case of emergency
Charge status display with green LED
High-temperature Ni-Cd battery cells
Overcharge and deep discharge protection
Wall and ceiling mounted
(*)Optional - Fire line application
Optional - 110 VAC compatibility

* The sensor is out-of-service when the luminaire is supplied on the fire line in case of emergency.

230 VAC CEM1 -IıIı- EN


SELV 50/60 Hz IP 20 PCB SMD Ni - Cd 60598-2-22

In accordance with EN 60598-1, EN 60598-2-22 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz SENSOR TYPE : 360º PIR Sensor
AMBIENT TEMPERATURE (ta) : 0 °C … +40 °C CASE MATERIAL : Iron Sheet
RATED DURATION : 3h LIGHT SOURCE : 60 pcs SMD LED
BATTERY CHARGING TIME : 24 h PROTECTION CLASS : IP 20
BATTERY TYPE : 3,6 V Ni-Cd INSULATION CLASS : I

PRODUCT LIST
PRODUCT RATED OPERATING LIGHT LIGHT INTENSITY on TYPE of BATTERY
CODE** DURATION MODE* SOURCE ENERGY/EMERGENCY MOUNTING CHARGING TIME

AA106-VATOZ-L6SD/9W - Luminaire + Sensor 9 W / - LED 1000 lm / - Surface Mounted -


AA106-VATOZ-L6SD/9W/K 3h Maintained + Sensor 9 W / 3 W LED 1000 lm / 250 lm Surface Mounted 24 h

* Luminaire:Lights just on mains


Maintained: Lights on mains and stays alight in case of the mains failure. (With battery kit)
Sensor: Lights on mains through sensor.

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice 157
EMERGENCY LIGHTING MAINS DATA
LUMINAIRES – LED PRODUCT
CODE
RATED
POWER (W)*
MAINS
CURRENT (A)*
POWER
FACTOR (PF)*
DIMENSIONS
(mm)
WEIGHT
(kg)
QTY
in CARTON BOX
TETRA-PW2 AA209-PW2 1,25 - 8,90 0,010 - 0,063 0,50 - 0,61 90 x 240 x 200 4,00 1

* Measured under 230 V mains.


Maximum values are measured with discharged batteries and values are minimum measured with full-charged batteries.
180° adjustable headlamp
SMD Power LED application
Emergency lighting function by interruption of the unswitched phase
Emergency lighting function in case of low-voltage
3 h duration in case of emergency
Battery capacity status display with green LED TECHNICAL DRAWING WIRING DIAGRAM
Test switch
Maintenance-free sealed lead acid battery
Overcharge and deep discharge protection
Charging circuit with constant voltage and current protection
Wall mounted
Emergency case on/off button
Powder coated, white iron sheet case
Optional - 110 VAC compatibility

LED SPOT
LIGHT DISTRIBUTION CURVE
230 VAC CEM1 -IıIı- EN
SELV 50/60 Hz IP 20 SMD Lead-Acid 60598-2-22
PCB

In accordance with EN 60598-1, EN 60598-2-22 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz HEADLAMP TYPE : 9W LED
AMBIENT TEMPERATURE (ta) : 0 °C … +40 °C CASE MATERIAL : Iron Sheet
RATED DURATION : 3h PROTECTION CLASS : IP 20
BATTERY TYPE : 12V Lead-Acid INSULATION CLASS : I

PRODUCT LIST
PRODUCT RATED OPERATING LIGHT LIGHT INTENSITY on TYPE OF BATTERY
CODE DURATION MODE* SOURCE ENERGY/EMERGENCY MOUNTING CHARGING TIME

AA209-PW2 3h Non-Maintained 2x9 W LED - / 1500 lm Surface Mounted 48 h

* Non-Maintained : Lights in case of the mains failure.

* Above curve is measured data just for one headlamp

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice 159
EMERGENCY LIGHTING MAINS DATA
LUMINAIRES – LED PRODUCT
CODE
RATED
POWER (W)*
MAINS
CURRENT (A)*
POWER
FACTOR (PF)*
DIMENSIONS
(mm)
WEIGHT
(kg)
QTY
in CARTON BOX
TETRA-PW3 AA209-PW3 1,25 - 8,90 0,010 - 0,063 0,50 - 0,61 98 x 255 x 205 4,50 1

* Measured under 230 V mains.


Maximum values are measured with discharged batteries and values are minimummeasured with full-charged batteries.
180° adjustable LED headlamp
SMD power LED application
Long life-time (30.000 hours)
Emergency lighting function by interruption of the unswitched phase WIRING DIAGRAM TECHNICAL DRAWING
Emergency lighting function in case of low-voltage
3 hours duration in case of emergency
Battery capacity status display with green LED
Test switch
Maintenance-free sealed lead acid battery
Overcharge and deep discharge protection
Charging circuit with constant voltage and current protect
Wall mounted
ABS case
Optional - 110 VAC compatibility

LIGHT DISTRIBUTION CURVE


TÜVRheinland LED SPOT

230 VAC GW CEM1 -IıIı- EN


SELV 50/60 Hz IP 65 850°C PCB SMD Lead-Acid 60598-2-22

In accordance with EN 60598-1, EN 60598-2-22 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz HEADLAMP TYPE : 9W LED
AMBIENT TEMPERATURE (ta) : -5 °C … +40 °C CASE MATERIAL : ABS
RATED DURATION : 3h PROTECTION CLASS : IP 65
BATTERY TYPE : 12V Lead-Acid INSULATION CLASS : II

PRODUCT LIST
PRODUCT RATED OPERATING LIGHT LIGHT INTENSITY on TYPE of BATTERY
CODE DURATION MODE* SOURCE ENERGY/EMERGENCY MOUNTING CHARGING TIME

AA209-PW3 3h Non-Maintained 2x9W LED - / 1500 lm Surface Mounted 48 h

* Non-maintained : Lights in case of the mains failure.

* Above curve is measured data just for one headlamp

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice 161
EMERGENCY LIGHTING LUMINAIRES MAINS DATA
HALOGEN LAMP PRODUCT
CODE
RATED
POWER (W)*
MAINS
CURRENT (A)**
POWER
FACTOR (PF)*
DIMENSIONS
(mm)
WEIGHT
(kg)
QTY
in CARTON BOX
TETRA AA1207-AA1Y 3,3 - 27,9 0,023 - 0,141 0,83 106 x 279 x 273 4,820 1
AA1214-AA1Y 3,8 - 28,6 0,028 - 0,148 0,83 135 x 320 x 375 7,630 1
AA1507-AA1Y 3,3 - 27,9 0,023 - 0,141 0,83 106 x 279 x 273 4,820 1
AA1514-AA1Y 4,0 - 30,6 0,030 - 0,145 0,83 135 x 320 x 375 8,570 1
Indoor and outdoor use AA2207-AA2Y 3,3 - 27,9 0,023 - 0,141 0,83 135 x 320 x 375 5,850 1
Portable AA2214-AA2Y 3,8 - 28,6 0,028 - 0,148 0,83 135 x 320 x 375 7,950 1
180° adjustable halogen headlamp AA2228-AA2Y 5,4 - 28,6 0,033 - 0,149 0,83 135 x 320 x 375 12,150 1
Moisture - proof AA2514-AA2Y 3,8 - 28,6 0,028 - 0,148 0,83 135 x 320 x 375 8,420 1
Emergency lighting function by interruption of the unswitched phase AA2528-AA2Y 5,6 - 30,6 0,035 - 0,155 0,83 128 x 394 x 450 13,740 1
Emergency lighting function in case of low-voltage
1 ... 6 h duration in case of emergency * Measured under 230 V mains.
Battery capacity status display with green LED ** Maximum values are measured with discharged batteries and values are minimum measured with full-charged batteries.
Lamp error status display with green LED
Test switch
Maintenance-free sealed lead acid battery
Overcharge and deep discharge protection
Charging circuit with constant voltage and current protect
Wall mounted TECHNICAL DRAWING WIRING DIAGRAM
Optional - on/off button
Optional - 110 VAC compatibility

HALOGEN

230 VAC CEM1 -IıIı- EN


SELV 50/60 Hz IP 44 PVC PCB SMD Lead-Acid 60598-2-22

In accordance with EN 60598-1, EN 60598-2-22 standards.

TECHNICAL DATA
SUPPLY VOLTAGE : 230 VAC 50/60 Hz HEADLAMP TYPE : 20 / 55 W Halogen
AMBIENT TEMPERATURE (ta) : 0 °C … +40 °C CASE MATERIAL : PVC
RATED DURATION : 1-6h PROTECTION CLASS : IP 44
BATTERY CHARGING TIME : 24 - 96 h INSULATION CLASS : II
BATTERY TYPE : 12 V Lead-Acid

PRODUCT LIST
PRODUCT RATED OPERATING LIGHT LIGHT INTENSITY on TYPE OF BATTERY
CODE DURATION MODE* SOURCE ENERGY/EMERGENCY MOUNTING CHARGING TIME

AA1207-AA1Y 3h Non-Maintained 1x20 W - Halogen - / 350 lm Surface Mounted 24 h


AA1214-AA1Y 6h Non-Maintained 1x20 W - Halogen - / 350 lm Surface Mounted 48 h
AA1507-AA1Y 1h Non-Maintained 1x55 W - Halogen - / 850 lm Surface Mounted 24 h
AA1514-AA1Y 2,5 h Non-Maintained 1x55 W - Halogen - / 850 lm Surface Mounted 48 h
AA2207-AA2Y 1h Non-Maintained 2x20 W - Halogen - / 700 lm Surface Mounted 24 h
AA2214-AA2Y 3h Non-Maintained 2x20 W - Halogen - / 700 lm Surface Mounted 48 h
AA2228-AA2Y 6h Non-Maintained 2x20 W - Halogen - / 700 lm Surface Mounted 96 h
AA2514-AA2Y 1h Non-Maintained 2x55 W - Halogen - / 1700 lm Surface Mounted 48 h
AA2528-AA2Y 2,5 h Non-Maintained 2x55 W - Halogen - / 1700 lm Surface Mounted 96 h
* Non-Maintained : Lights in case of the mains failure.
Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice 163
STANDARDS &
ICONS
Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice 165
STANDARDS & ICONS
Beş A products comply with the requirements of 2014/35/EU and 2014/30/EU are
EN 60598-1 General requirements and test for luminaires Part 1: General requirements and tests
entitled to bear the CE mark.
EN 60598-2-22 Particular requirements in respect of luminaires for emergency lighting
RoHS (Restriction of the use of certain Hazardous Substances in electrical and
EN 62031 Safety specifications for LED modules electronic equipment).

EN 62384 DC or AC supplied electronic control gear for LED modules Performance requirements
International and national approval marks.
TÜVRheinland

EN 62471 Photobiological safety of lamps and lamp systems


Protection class II device in which protection against electric shock is not based
EN 61347-1 General and safety requirements for lamp control gear solely on the basic insulation but in which there are additional safety features such
as double or enhanced insulation.
EN 61347-2-7 Lamp controlgear - Part 2-7: Particular requirements for battery supplied
electronic control gear for emergency lighting (self-contained)
SELV Safety Extra-Low-voltage (<60V or <120V)
EN 61347-2-13 Lamp controlgear - Part 2-7: Particular requirements for battery supplied
electronic control gear for emergency lighting (self-contained)

EN 62386-102 Digital Addressable Lighting Interface - Part 102: General rules - Control gear LED SPOT LED LAMP HALOGEN
LED or lamp usage

EN 62386-202 Digital Addressable Lighting Interface - Part 202: Special rules for control gear - TL-D / 4P PL-L / 4P PL-T / C / 4P
TL5 / 4P
Self emergency lighting (device type1)

EN 62386-207 Numerically Addressable Lighting Interface - Part 207: Specific features for the control layout - 230 VAC 110 VAC 24 V Mains voltage for the product
50/60 Hz 50/60 Hz AC/DC
LED modules (type 6 device)

EN 62034 Automatic test systems for battery powered emergency escape lighting
IP 20 IP 44 IP 65 Insulation class
EN 60929 AC and/or DC-supplied electronic control gear for tubular fluorescent lamps
Performance requirements
41 GW PVC Body material of the product
ALU 850°C
EN 61547 EMC immunity requirements

EN 55015 Limits and methods of measurement of radio disturbance characteristics of electrical ligthing and similar CEM1 CEM3 FR4 PCB material
PCB PCB PCB
equipment

EN 1838 Lighting applications - Emergency lighting


SMD SMD technology application

EN 50172 Emergency escape lighting systems


-IıIı- -IıIı-
ISO 16069 Graphical symbols - Safety signs - Safety way guidance systems (SWGS) Ni - Cd Lead-Acid Battery type

ISO 3864-1 Graphical symbols - Safety colours and safety signs


EN EN EN
61347-2-7 61347-2-13 61347-2-3
EN ISO 7010 Graphical symbols - Safety colours and safety signs - Registered safety signs
International standard code
EN EN EN
60598-2-22 62386 62034

OSRAM LED Technology included

Compatible with DALI (Digital Addressable Lighting Interface)


ELCO: Wired Emergency Lighting Monitoring System

WELCO: Wireless Emergency Lighting Monitoring System


Product consist of Wi-Fi module. Monitoring System via Cloud with WELCO software

Beş A reserves the right to change the technical and visual specifications and/or to discontinue the products without prior notice 167
BEŞ A ELEKTRİK VE ELEKTRONİK
SAN. VE TİC. LTD. ŞTİ

Çengeldere Mah. Çengeldere Cad. No:105


Kat:2 Çavuşbaşı Beykoz / İstanbul
T: +90 216 479 66 77 (pbx)
F: +90 216 479 70 50
E: [email protected]

www.bes-a.com

www.kosgeb.gov.tr

You might also like