Base Plate Design: Factored Loads
Base Plate Design: Factored Loads
230
Size of the column NPB300x150x49.3 35.5 b (1mm strip)
Factored loads: 85 mm x y
For Compression
152
Assume the base plate size as 230 x 375 Concrete Grade, fck = 25 N/mm2
Total length availble for welding along the periphery of column fwn = fu / √3 gmw = 1.25
2x(152-12.7+304)-8 = 878.6 mm = 236.71 fwd = fwn / gmw
Deducting length 10% for end return = 790.74 mm = 189.37
Tdg = 1427.727
Capcacity of 6 mm weld = 0.803 kN/mm Tdn = 1854.446
For Tension
Support reaction = 228.94 KN (Max Tension)
Assume 4 Nos. 24 dia H.D bolts Grade 4.6 (Bearing type bolt)
Tension capacity of bolt Tdb = Tnb / gmb (As per Cl. 10.3.5) gmb = 1.25 (As per IS 800- 2007,Table 5)
Tnb = 0.9 fub An < fyb Asb (gmb / gm0) fyb= 240 N/mm
2
fub = 400 N/mm
2
2
0.9 f ub An = 130.29 KN Shank area of the bolt(Asb)= 452.39 mm
fyb Asb (gmb/gm0)= 123.38 KN Net tensile area at the bottom of threads (An)= 361.912 mm^2
Tnb = 123.38 KN ( Approx. 80 % of Asb)
ε = (250/fy)1/2
=1
Maximum Edge Distance = 192 mm
Pitch Distance
a1 = 35.50 mm 490.66 KN
b1 = 230.00 mm
\ = 8.88 mm Assume b = 1
5.69
0.8 0.097
0.9 0.107
0.87 0.104
a1 = 111 mm
d1 = 128 mm
d1=
free edge
Thickness of plate required = √(6 Md γmo /1.2* b fy) As per IS 800- 2007,Clause 8.2.1.2
= 14.58 mm
Shear capacity of bolt
Vdpb = 163.74 kN do = 26 mm
fy = 250
Design of Stiffners
Moment at the face of the column web -(for compression in the coulmn)
Height of plate required = √(6 Md gmo / b fy) As per IS 800- 2007,Clause 8.2.1.2
FINAL SUMMARY
230
Dia. Of Bolt 24 mm 35.5
No. of Bolts 4 Nos. 85 mm
Thickness of Plate 16 mm 304 375
Size of Plate 230 x 375 mm
Heigh of Stiffner 150 mm C/C = 100
Thickness os stiffner plate 12 mm
152