HPS PMC Enraf VITO MTT Combi Probe

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

VITO MTT Combi Probe

Advanced sensor technology.


The VITO MTT temperature & water probe together with
Honeywell Enraf automatic tank gauging equipment is the answer
for accurate inventory management on tanks containing product and
free water. VITO MTT uses industry leading Multiple Thermosensor
Thermometer sensing technology for reliable measurement of
average product temperature, water bottom level, vapor temperature
and temperature profiles. It is also fully compliant with legal metrology
requirements and API MPMS Chapter 7, Section 3. A robust design,
meanwhile, ensures minimal maintenance and easy installation.
Global Experience. Locally Applied.
Technical Specifications

Temperature Sensing: 766 VITO Temperature & Water Probe


Principle
Measuring principle Cold junction compensated thermocouples (type T) to measure the temperature differentials with
respect to a 4 wire 1/5 DIN Class A Pt100 reference resistor, physically embedded to cold junction.
Number of elements 16 temperature elements
Measuring Specifications
766 Probe temp. range -55 °C to +135 °C (-67 °F to +275 °F)
Storage temperature -55 °C to +135 °C (-67 °F to +275 °F)
Probe accuracy ±0.1 °C (±0.18 °F) *1
Measuring resolution 0.01 °C (0.01 °F)
Measuring length Refer to Identification Code (also see dimensional drawing). For longer probes consult factory.

Water Sensing: 766 VITO Temperature & Water Probe


Principle
Principle PTFE sheathed capacitive probe
Measuring Specifications
Measuring range Depending on identification code, 50 cm (20”), 100 cm (39”) and 200 cm (79”)
Accuracy ±2 mm (0.078”) *1, water is measured only between 0 °C to +100 °C (+32 °F to +212 °F)
process temperature range.
Measuring resolution 0.1 mm (0.004”)
Minimum water level 25 mm (0.98”)

General: 766 VITO Temperature & Water Probe


Mechanical
Sheathing Stainless steel AISI 316L (mat. no. 1.4404) corrugated probe
Adjusting pipe Stainless steel AISI 316L (mat. no. 1.4404), adjustable length: ±230 mm (±9”), ISO 228/1-G1/2B (1/2’’ BSP)
Lining water probe PFA (fluoropolymer)
Outer diameter of probe 40 mm (1.57”)
Mounting flange Optional, 1/2 BSP threaded mounting hole required
Anchor weight Optional, max. 23 kg (50 lb)
Environmental Safety
Operating pressure 5 bar / 500 kPa (72 psi) Hydrostatic pressure
Safety – II 1G Ex ia IIB T4 Ga; acc. to ATEX KEMA 01ATEX1212
– Ex ia IIB T4 Ga; acc. to IECEx KEM 05.0014
– Ex ia IIB Ta; acc. to Kosha certificate; 13-AV4BO-0487
– Class I, Division 1, Groups C & D; acc. to FM I. D. 3015746
– Class I, Division 1, Groups C & D; acc. to CSA certificate 1635480
– Ex ia IIB T4 Ga; acc. to INMETRO TÜV 13.0975 X
For other approvals and updates please consult factory
Electrical
Flying lead length Color coded PTFE insulated stranded wires. Length: 35 cm (14”) and 120 cm (47”)

762 VITO Interface


Specifications
Application An electronic converter used in combination with the VITO probes
Data communication HART® communication to Tank Gauging ATG *2
Ambient temp. range -40 °C to +60 °C (-40 °F to +140 °F)
Storage temperature -40 °C to +60 °C (-40 °F to +140 °F)
Cable entry Cable entry options; M20 x 1.5, 3/4” NPT via reducer and PG16 via reducer
Mounting Direct on VITO probes using standard 1/2’’ BSP entry
Housing Chromatized, Polyurethane coated Aluminum, GD-AISi10Mg
Ingress protection IP66 / IP67 according to EN 60529 (NEMA 4X)
Safety – II 1/2G Ex ia IIB T4 Ga/Gb; acc. to ATEX KEMA 01ATEX1212
– Ex ia IIB T4 Ga/Gb; acc. to IECEx KEM 05.0014
– Ex ia IIB Ta; acc. to Kosha certificate; 13-AV4BO-0487
– Class I, Division 1, Groups C & D; acc. to FM I. D. 3015746
– Class I, Division 1, Groups C & D; acc. to CSA certificate 1635480
– Ex ia IIB T4 Ga/Gb; acc. to INMETRO TÜV 13.0975 X
For other approvals and updates please consult factory
Note(s):
*1
Under reference conditions.
*2
HART® is a registered trademark of the HART Communications Foundation.
Identification Code: 766 VITO Temperature & Water Probe
Pos 1 W&M Approved
U General purpose
X With W&M type approval (only for temperature)
Pos 2 Sensitive Length for Water Bottom Measurement
A 050 cm
B 100 cm
C 200 cm
Pos 3 Safety Approvals
A ATEX Europe
F FM USA
I INMETRO Brazil
Pos 4 Length Flying Lead
N 35 cm (standard)
O 120 cm
Pos 5, 6, 7 Product Designation
7 6 6 VITO temperature and water probe
Pos 8 Position of Lowest Temperature Element
C Lowest element at minimum 1 meter from bottom of probe (acc. API)
D Lowest element at bottom of probe
Pos 9, 10, 11, 12 Overall Length in Steps of 10 cm (Price per Meter)
# # # 0
Range 0420 - 3390 if Pos 2 = A
# # # 0
Range 0470 - 3390 if Pos 2 = B
# # # 0
Range 0570 - 3390 if Pos 2 = C
Pos 13, 14, 15, 16 Position of Highest Temperature Element
(at least 70cm from top of probe)
# # # 0 Range 0350 - 3320 in steps of 10 cm if Pos 2 = A

# # # 0 Range 0400 - 3320 in steps of 10 cm if Pos 2 = B

# # # 0 Range 0500 - 3320 in steps of 10 cm if Pos 2 = C

Pos 17 Separator
/

Pos 18 Tag Plate
Z No Tag plate
T Tag plate (Material: CuNi alloy)

U A A N 7 6 6 C 1 2 5 0 1 0 2 0 / Z Typical Identification Code
A 7 6 6 0 /
0 Your Identification Code
Identification Code: 762 VITO Interface
Pos 1 W&M Approved
U General purpose
X With W&M type approval only if Pos 2 = T
Pos 2 Version
P VITO LT interface (for VITO LT probe)
R VITO MRT interface for resistance measurements (MRT/RTD/361 MPT)
T VITO interface for 764/765/766/864 VITO probes
Pos 3 Position Not Used
*
Pos 4 Position Not Used
*
Pos 5, 6, 7 Product Designation
7 6 2 VITO interface
Pos 8 Ingress Protection
No
* IP adapter
I IP adapter (only if Pos 9 = A)
Note: recommended for environments with high humidity and strong fluctuations in ambient temperature.
Pos 9 Entry to Sensor
A G 1/2 (standard in box)
B 3/4” NPT (only when Pos 2 = R)
Pos 10 Cable Entry
G M20 x 1.5 (only when Pos 11 = A or I)
N 3/4” NPT; via reducer
S PG16 via reducer (only when Pos 11 = A or I)
Pos 11 Safety Approvals
A ATEX / IEC Ex Europe / Global
F FM / CSA USA / Canada
I INMETRO Brazil
Pos 12 Seperator
/
Pos 13 Tag Plate
Z No tag plate
T Tag plate (Material: CuNi alloy)

* * 7 6 2 * A G A / Z
U T Typical Identification Code

* * 7 6 2 /
Your Identification Code
Dimensional Drawing
766 VITO MTT Temperature and Water Probe
Dimensions in mm
Flying leads
G½ (BSP)
Lock nut with lock washer

±230 >70
Max. Flange position
Label VITO probe
Flange (optional)

>700
Position highest element

Overall Length
Highest Element
ø40

155
Sensitive length

500, 1000, 2000


water probe
25
ø35

762 VITO Interface Space needed


Dimensions in mm (inches) to remove cover

Instrument Label 146 (5 3/4”)

Tag plate (optional)


Ø 200 (7 7/8”)

VITO MTT Interface 762


Serial no:
Test date:
118 (4 5/8”)

Cable entry

External
Probe entry grounding
terminal
All technical specifications are subject to change without notice.

For More Information


To learn more about Honeywell Enraf’s solutions,
visit www.honeywellenraf.com or contact
your Honeywell account manager.

Americas Asia Pacific


Honeywell Enraf Americas, Inc. Honeywell Pte Ltd.
2000 Northfield Ct. 17 Changi Business Park Central 1
Roswell, GA 30076 Singapore 486073
USA Phone: +65 6355 2828
Phone: +1 770 475 1900 Email: [email protected]
Email: [email protected]

Europe, Middle East and Africa


Honeywell Enraf
Delftechpark 39
2628 XJ Delft
The Netherlands
Phone: +31 (0)15 2701 100 EN-13-06-ENG
Your Terminal Operations Partner
May 2015
Email: [email protected] © 2015 Honeywell International Inc.