JFR Series FMCW Radar Level Transmitter
JFR Series FMCW Radar Level Transmitter
JFR Series FMCW Radar Level Transmitter
com
Design formula
TEST STANDARDS
High voltage : IEC60947-2
Isolated resistance : IEC60092-504
LINEARITY DIAGRAM Power supply change : IEC60092-504
Accuracy Power supply failure : IEC60092-504
cm
12
Electrical burst testing : IEC61000-4-4
10 A0.4% Voltage DIPS : IEC61000-4-11
8 A0.4%
6 A30mm A0.4% Humidity : IEC60068-2-30
A20mm
A0.2%
4
A10mm
High/Low temperature test : IEC60068-2-38
2
A5mm
0 A3mm A0.2%
IP protection rating : IEC60529
-2
-4
-6
-8
-10
-12
-14
-16
0.5m 5m 15m 20m
Distance to flange 1
SPECIFICATION (26GHz 4-wire)
f98 f98
1/2"PF 1/2"PF
217
Dimensions 210
(Unit:mm) 1-1/2"PF
60 60
2"NPT or 2"PF
PTFE PTFE
f43 f56
Accuracy A3 mm
Repeatability A1 mm
Frequency K Band
2
f98
f98
f98
1/2" PF compressed
air input
1/2" PF compressed
air input
1/2" PF 190
369 476
1-1/2" NPT
2"PF
Dimensions 2"PF
43
(Unit:mm) 162
270
f43
f100
f140
Min. Dielectric
constant (liquid) 1.4
Measuring range Liquid 40m Solid 30m Liquid 70m Solid 50m Liquid 20m Solid 15m
A3mm @distance<40m
Accuracy A3 mm A0.01%F.S. @distance>40m A3 mm
Repeatability A1 mm
Digital communication RS485 (Isolated)
Frequency K Band
Antenna type High gain horn (100) High gain horn (140) Lens(43DS)
P.S. For JFR-224 and JFR-234, customer can connect the compressed air with 1/8"PT thread
connector to avoid dust adhered. 3
SPECIFICATION (26GHz 2-wire)
f98
f98
1/2"PF 1/2"PF
210 217
Dimensions 1-1/2"PF
(Unit:mm) 60
2"NPT or 2"PF 60
PTFE PTFE
f43 f56
Accuracy A5mm
Repeatability A3mm
Digital communication HART
Ambient temperature -40~90BC(LCM<75BC)
Operating temperature -40~200BC
Operating pressure 0~40 bar
Frequency K Band
Analog output 4~20mA
4
f98
f98
f98
1/2" PF compressed
air input
1/2" PF compressed 190
1/2" PF
air input 1-1/2" NPT
369 476
2"PF 43
Dimensions
2"PF 270 f43
(Unit:mm) 162
f100
f140
Antenna type High gain horn (100D) High gain horn (140D) Lens (43DS)
P.s. For JFR-222 and JFR-232, customer can connnect the compressed air with 1/8"PT thread connector
to avoid dust adhered. 5
WIRING/CALIBRATION
1 V+
POWER
2 V-
DC24V
5
6
1 2 3 4 5 6 1 2
TR- TR+
1 Power Supply: V+
RS232/485
Converter
2 Power Supply: V-
3 Analog Output: I+ (4~20mA)
RS232 Interface / USB Interface
4 Analog Output: I- (4~20mA)
5 Communication: TR+ (RS485)
JFR Series and Indicator(External Power) 6 Communication: TR- (RS485)
1 V+
CALIBRATION
POWER
2 V-
3
DC24V Two ways to calibrate the JFR Series:
4 4-wire:
I+ 1. Display/Adjustment module
2. By pcbased fas soft ware
I-
2-wire:
Panel Meter
1. Display/Adjustment module
2. HART
1 V+
POWER Adjustment module is an adjustment tool with
DC24V
4 buttons to click on. It also has a transparent
2
V- window to allow display reading.
[ ] Button [ ] Button
-Enter Edit status -Select Edit
-Confirm Edit -Select parameter
-Confirm parameter -Parameter
modification
[ ] Button [ ] Button
-Return -Increase
-Cancel -Select
6
PARAMETER SETTING
100%
0%
7
INSTALLATION
1. JFR-20x can be hidden in the extension tube, the 4. JFR-24x can be hidden in the extension tube, the
recommendation of the tube diameter D and length L recommendation of the tube diameter D and length L
are shown in the table. are shown in the table.
L
L
D
D
Diameter D (Inch) Length L (Inch)
2" L£ 160 Diameter D (Inch) Length L (Inch)
2. JFR-21x can be hidden in the extension tube, the 5. Installation recommendations are as follows :
recommendation of the tube diameter D and length L (1) Antenna installation angle to be perpendicular to the
are shown in the table. Horizontal.
(2) JFR installation position with the drum wall suggestions
Are as follows :
Installation location A should be less than 1/6D
Range with A relation is as follows :
a.H<10m, A>300mm
L b.10m<H<20m, A >600mm
D c.H>20m, A>900mm
D
L
D
Model Diameter D (Inch) Length L (Inch)
JFR-22X D>100 L£ 150
JFR-23X D>140 L£ 270
8
2. Radar installation should not be too close to the drum 6. If drum internal agitator will have a strong vortex and
wall, avoid the drum wall attachment material reflection foam, drum must increase waveguide, the upper
interference. waveguide drill vent holes to ensure the correctness of
the measured value.
vent hole
X
X
3. Radar installation not too close to the drum bracket to 7. Installation should be avoided in the feed inlet position,
avoid reflection is incorrect avoid material interference or obstacles interference.
X X
4. When obstructions inside the tank, tank be fitted with 8. Installation should be avoided in the top center of the
eflectors, steer clear of the error echo reflected to the arch or round barrel will cause multiple echo reflections.
receiver, causing radar miscalculation.
Reflector
X
X
9
MODEL NUMBER / ORDER CODE COMPARISON TABLE
10
ORDER INFORMATION
09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
JFR 2 0 0 0 0 -999999999999999
09 10 Antenna type
A1: Horn(43D)
A2: Horn(100D/162L)
A3: Horn(140D/270L)
A4: Lens(43DS)
A5: Lens(56D)
B1: Horn(100D/126L)
B2: Horn(140D/202L)
11 12 Antenna material
MA: SUS 304
MB: SUS 316
MC: SUS 316L
21: PTFE coating
Connection
13 14 15 16 17 18
11
09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
JFR 2 0 0 0 0 -999999999999999
19 20 Flange material
MA: SUS 304
MB: SUS 316
MC: SUS 316L
MD: SS41 zinc coating
18: PP
21: PTFE
00: None
21 Output
A: Loop Power 24 Vdc with HART
B: 4-Wire 24Vdc 4~20mA with RS-485
C: Loop Power 24 Vdc, 4~20mA
22 Accuracy
A: K3mm
B: K5mm
C: K10mm
D: K20mm
※2 Wire only option A:A5mm or C:A10mm
23 Measuring distance
A: 10m
B: 20m
C: 30m
D: 40m
E: 70m
12
JFR Radar Level Transmitter
Customer Information Prepared by: Date:
Company: Industry:
Address:
Application Information
B.1 Measuring Material Information
Application Description:
B.6 Connection
Connection: 9 Threaded 9 Flange
Size and Standard: Flange Material:
B.7 Tank Information
9 Vertical Cylinder 9 Horizontal Cylinder 9 Spherical
Tank Shape
9 Cubical/rectangular 9 Other:
Tank Material 9 Cubical 9 Plastic 9 Cement 9 Other
9 Metal
9 Plastic
Tank Bottom
9 Cement
9 Other
Tank
Tank Height (H): m D3 D1
Tank Diameter (W): m
Cone Height (H1): m
Nozzle
(Ignore cone height with flat/disk bottom )
L
Radar
Distance to tank wall(D1): m D
Nozzle
9 Yes
Nozzle Diameter (L): m Ladder
Nozzle Height (D): m
9 NO
H
Ladder
9 Yes W
Distance to rada (D3): m
9 NO
Heater
9 Yes
9 NO
H1
Germany
China
Taiwan U.S.
Singapore
Malaysia
Indonesia
China
Fine automation Co., Ltd. - Shanghai Factory Mütec Instruments GmbH - Germany Office
No.451 DuHui Rd, MinHang District, Shanghai, Bei den Kämpen 26
China 201109 21220 Seevetal-Ramelsloh, Germany
TEL: 86-21-6490-7260 TEL: +49-(0)4185-8083-0
EMAIL: [email protected] FAX: +49-(0)4185-8083-80
EMAIL: [email protected]
Singapore
FineTek Pte Ltd. - Singapore Office
No. 60 Kaki Bukit Place, #07-06 Eunos
Techpark 2 Lobby B, Singapore 415979
TEL: 65-6452-6340
EMAIL: [email protected]
Indonesia
FineTek Co., Ltd. - Indonesia Office
Ruko Golden 8 Blok H No.38
Gading Serpong, Tangerang, Indonesia
TEL: 62 (021)-2923-1688
EMAIL: [email protected]
Malaysia Distributor:
FineTek Co., Ltd. - Malaysia Office
8-05, Plaza Azalea, Persiaran Bandaraya,
Seksyen 14, 40000 Shah Alam, Selangor, Malaysiac
TEL: 603-5524-7168
EMAIL: [email protected]
08-JFREP, 010417