The 6MD63 bay control unit is a flexible and easy-to-use control unit optimized for medium-voltage applications. It provides switchgear interlocking, automation configuration, position indication of switching devices, and local/remote switching capabilities. Communication interfaces include IEC 61850, IEC 60870-5-103, and several other protocols. The unit has a large graphic display and keyboard for operation and is available in various housing and mounting options.

Uploaded by

ĦøÐâ
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
66 views2 pages

6MD63 en SH

The 6MD63 bay control unit is a flexible and easy-to-use control unit optimized for medium-voltage applications. It provides switchgear interlocking, automation configuration, position indication of switching devices, and local/remote switching capabilities. Communication interfaces include IEC 61850, IEC 60870-5-103, and several other protocols. The unit has a large graphic display and keyboard for operation and is available in various housing and mounting options.

Uploaded by

ĦøÐâ
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

13 Bay Units / 6MD63

SIPROTEC 4 6MD63
Bay Control Unit
Function overview

Application
• Optimized for connection to
three-position disconnectors
• Switchgear interlocking interface with
high-level control and protection
• Suitable for redundant master station
• Automation can be configured easily by
graphic means with CFC
Control functions
LSP2314-afp.tif

• Number of switching devices only lim-


ited by number of available inputs and
outputs
• Position of switching elements is shown
Fig. 13/1 on the graphic display
SIPROTEC 4
6MD63 bay control unit • Local/remote switching via key switch
• Command derivation from an indication
• 4 freely assignable function keys to
speed up frequently recurring operator
Description actions
The 6MD63 bay control unit is a flexible, • Switchgear interlocking isolator/c.-b.
easy-to-use control unit. It is optimally • Key-operated switching authority
tailored for medium-voltage applications • Feeder control diagram
but can also be used in high-voltage
substations. • Measured-value acquisition
• Signal and command indications
The 6MD63 bay control unit has the
same design (look and feel) as the other • P, Q, cos ϕ (power factor) and
protection and combined units of the meter-reading calculation
SIPROTEC 4 relay series. Configuration is • Event logging
also performed in a standardized way with
• Switching statistics
the easy-to-use DIGSI 4 configuration tool .
Monitoring functions
For operation, a large graphic display with
a keyboard is available. The important • Operational measured values
operating actions are performed in a • Energy metering values
simple and intuitive way, e.g. alarm list dis-
• Time metering of operating hours
play or switchgear control. The operator
panel can be mounted separately from the • Slave pointer
relay, if required. Thus, flexibility with re- • Self-supervision of relay
gard to the mounting position of the unit
is ensured. Communication interfaces
• System interface 13
Integrated key-operated switches control
the switching authority and authorization – IEC 61850 Ethernet
for switching without interlocking. – IEC 60870-5-103 protocol
– PROFIBUS-FMS
– DNP 3.0
– PROFIBUS-DP
– MODBUS
– Service interface for DIGSI 4
(modem)/temperature detection
(thermo-box)
– Front interface for DIGSI 4
– Time synchronization via
IRIG-B/DCF 77

Siemens SIP · 2004 13/3


13 Bay Units / 6MD63

Selection and ordering data Description Order No. Order code


6MD63 bay control unit with local control 6MD63¨o ¨¨¨¨¨ ¨AA0 ¨¨¨
Housing, binary inputs (BI) and outputs (BO), measuring transducer
Housing ½ 19”, 11 BI, 8 BO, 1 live status contact 1
Housing ½ 19”, 24 BI, 11 BO, 4 power relays, 1 live status contact 2
Housing ½ 19”, 20 BI, 11 BO, 2 measuring transducer inputs,
4 power relays, 1 live status contact 3
Housing ½ 19”, 20 BI, 6 BO, 4 power relays, 1 live status contact 4 1)
Housing 1/1 19”, 37 BI, 14 BO, 8 power relays, 1 live status contact 5
Housing 1/1 19”, 33 BI, 14 BO, 2 measuring transducer inputs,
8 power relays, 1 live status contact 6
Housing ½ 19”, 33 BI, 9 BO, 8 power relays, 1 live status contact 7 1)

Current transformer In
No analog measured variables 0
1 A2) 1
5 A2) 5

Rated auxiliary voltage (power supply, indication voltage)


24 to 48 V DC, threshold binary input 19 V3) 2
60 to 125 V DC4), threshold binary input 19 V3) 4
110 to 250 V DC4), 115 to 230 V AC3), threshold binary input 88 V3) 5

Unit design
For panel surface mounting, plug-in terminal, detached operator panel A
For panel surface mounting, 2-tier terminal, top/bottom B
For panel surface mounting, screw-type terminal, detached operator panel C
For panel flush mounting, plug-in terminal (2/3 pin AMP connector) D
For panel flush mounting, screw-type terminal
(direct connection/ring-type cable lugs) E
For panel surface mounting, screw-type terminal
(direct connection / ring-type cable lugs), without HMI F
For panel surface mounting, plug-in terminal without HMI G

Region-specific default settings/function versions and language settings


Region DE, 50 Hz, IEC, language: German, changeable A
Region World, 50/60 Hz, IEC/ANSI, language: English (GB), changeable B
Region US, 60 Hz, ANSI, language: English (US), changeable C
Region FR, IEC/ANSI, language: French, changeable D
Region World, IEC/ANSI, language: Spanish, changeable E

System interface (on rear of unit/Port B )


No system port 0
IEC 60870-5-103 protocol, electrical RS232 1
IEC 60870-5-103 protocol, electrical RS485 2
IEC 60870-5-103 protocol, 820 nm fiber optic, ST connector 3
PROFIBUS-FMS Slave, electrical RS485 4
PROFIBUS-FMS Slave, fiber optic, single ring, ST connector5) 5
PROFIBUS-FMS Slave, fiber optic, double ring, ST connector5) 6
PROFIBUS-DP Slave, RS485 9 L 0 A
13 PROFIBUS-DP Slave, 820 nm fiber optic, double ring, ST connector5) 9 L 0 B
MODBUS, RS485 9 L 0 D
MODBUS, 820 nm fiber optic, ST connector5) 9 L 0 E
1) Only for position 7 = 0
DNP 3.0, RS485 9 L 0 G
2) Rated current can be selected by DNP 3.0, 820 nm fiber optic, ST connector5) 9 L 0 H
means of jumpers. IEC 61850, 100 Mbit Ethernet, electrical, double, RJ45 connector 9 L 0 R
3) The binary input thresholds can be
selected in two stages by means of DIGSI 4/modem interface (on rear of unit/Port C)
jumpers. No port on rear side 0
4) Transition between the two auxiliary DIGSI 4, electrical RS232 1
voltage ranges can be selected by DIGSI 4, electrical RS485 2
means of jumpers. DIGSI 4, optical 820 nm, ST connector 3
5) Not with position 9 = “B”; if 9 = “B”;
please order 6MD6 unit with RS485 Measuring
port and separate fiber-optic con- Basic metering (current, voltage) 0
verter.
Slave pointer, mean values, min/max values only for position 7= 1 and 5 2
13/4 Siemens SIP · 2004

You might also like