CVGV Full en Metric Letter

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

MODEL Vented pilot-to-open check valve

CVGV SERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-23A

snhy.com/CVGV

This valve is a pilot to open check valve. It has a sealed pilot, a steel seat, and is vented. It allows free flow from
the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) will open
the valve from port 1 to port 2. Pilot pressure needed to open the valve is directly proportional to the load pressure
at port 1. The valve is insensitive to pressure at port 2 because the spring chamber is referenced to the vent (port
4).

TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.

Cavity T-23A
Series 3
Capacity 240 L/min.
Pilot Ratio 3:1
Maximum Operating Pressure 350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 0,07 cc/min.
Valve Hex Size 31,8 mm
Valve Installation Torque 203 - 217 Nm
Seal kit - Cartridge Buna: 990023007
Seal kit - Cartridge Polyurethane: 990023002
Seal kit - Cartridge Viton: 990023006
Model Weight 0.68 kg.

CONFIGURATION OPTIONS Model Code Example: CVGVXCN


CONTROL (X) CRACKING PRESSURE (C) SEAL MATERIAL (N) MATERIAL/COATING
X Standard Pilot C 30 psi (2 bar) N Buna-N Standard Material/Coating
L Manual Load Release A 4 psi (0,3 bar) V Viton /AP Stainless Steel, Passivated
B 15 psi (1 bar) /LH Mild Steel, Zinc-Nickel
D 50 psi (3,5 bar)
E 75 psi (5 bar)
F 100 psi (7 bar)

c 2019 Sun Hydraulics 1 of 2


TECHNICAL FEATURES
Pilot pressure as low as 75 psi (5 bar) higher than the pressure at the vent can prevent the valve from closing.
Will accept pressure at port 4 (vent) but can not exceed 5000 psi (350 bar).
Pilot-to-open check cartridges are locking valves, not motion control valves. For motion control applications, use counterbalance valves.
Four-port pilot-to-open check cartridges and four-port counterbalance cartridges are physically interchangeable (i.e. same cavities, same flow path for a given frame
size). However, cartridge extension dimensions from the mounting surface may vary.
Approximately 1 drop (0,07 cc) of fluid will pass from the pilot area to the vented spring chamber every 4000 cycles.
Provides hose break protection, prevents loads from drifting and positively locks pressurized loads.
Extremely low leakage. The seat and poppet are heat treated for long life. If the load drifts due to the valve, the seat has probably been damaged by contamination
and the valve should be replaced.
Sealed pilot for use in circuits where cross port leakage is undesirable.
Port 4 (vent) should never be blocked as seal weepage will eventually cause valve to malfunction.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.