Jaguar - XF - X250 - 3L - TDV6 - Diesel - Workshop - Manual - 2012 - 231026 - 122234 (1) - 1-1000

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1000

Search this document...

Hide document tree


Hide document tree

1: General Information
100: Service Information
100-00: General Information
Description and Operation
About This Manual
Application and Use of Specifications
Battery and Battery Charging Health and Safety Precautions
Brake System Health and Safety Precautions
Diesel Fuel System Health and Safety Precautions
Fluid Leaks
General Service Information
Health and Safety Precautions
How To Use This Manual
Important Safety Instructions
Petrol and Petrol-Ethanol Fuel Systems Health and Safety Precautions
Smart Key Transmission Frequency
Solvents, Sealants and Adhesives
Standard Workshop Practices
Symbols Glossary
Supplementary Restraint System Health and Safety Precautions
Road/Roller Testing
Window Glass Health and Safety Precautions
Diagnostic Trouble Code IndexDTC: Active Safety Belt Module (SPMA/SPMB)
Diagnostic Trouble Code IndexDTC: Adaptive Damping Module (SUMB)
Diagnostic Trouble Code IndexDTC: Anti-Lock Braking System (ABS)
Diagnostic Trouble Code IndexDTC: Audio Amplifier Module (AAM)
Diagnostic Trouble Code IndexDTC: Blind Spot Monitoring System Module
(SODL/SODR)
Diagnostic Trouble Code IndexDTC: Central Junction Box (CJB)
Diagnostic Trouble Code IndexDTC: Climate Control Module (HVAC)
Diagnostic Trouble Code IndexDTC: Digital Audio Broadcast Module (DABM)
Diagnostic Trouble Code IndexDTC: Driver Door Module/Passenger Door Module
(DDM/PDM)
Diagnostic Trouble Code IndexDTC: Driver/Passenger Seat Module (DSM/PSM)
Diagnostic Trouble Code IndexDTC: Electric Parking Brake (PBM)
Diagnostic Trouble Code IndexDTC: Engine Control Module - 2.2L I4 - DW12C (PCM)
Diagnostic Trouble Code IndexDTC: Engine Control Module - 3.0L NA V6 - AJ63 (PCM)
Diagnostic Trouble Code IndexDTC: Engine Control Module - 5.0L NA V8 - AJ133
(PCM)
Diagnostic Trouble Code IndexDTC: Engine Control Module - 5.0L SC V8 - AJ133 (PCM)
Diagnostic Trouble Code IndexTDV6 3.0L Diesel , DTC: Engine Control Module (ECM)
Diagnostic Trouble Code IndexDTC: Front Seat Climate Control Module (DCSM)
Diagnostic Trouble Code IndexDTC: Gateway Module (GWM)
Diagnostic Trouble Code IndexDTC: Headlamp Control Module (HCM)
Diagnostic Trouble Code IndexDTC: Headlamp Control Module B (HCMB)
Diagnostic Trouble Code IndexDTC: Instrument Cluster (IPC)
Diagnostic Trouble Code IndexDTC: Integrated Audio Module (ACM)
Diagnostic Trouble Code IndexDTC: Integrated Control Panel (FCIMB)
Diagnostic Trouble Code IndexDTC: Occupant Classification System (OCS)
Diagnostic Trouble Code IndexDTC: Parking Aid Module (PAM)
Diagnostic Trouble Code IndexDTC: Rear Differential Control Module (RDCM)
Diagnostic Trouble Code IndexDTC: Rear Junction Box (BCMB)
Diagnostic Trouble Code IndexDTC: Remote Keyless Entry Module (RFA)
Diagnostic Trouble Code IndexDTC: Restraints Control Module (RCM)
Diagnostic Trouble Code IndexDTC: Satellite Digital Audio Radio System Module
(SARM)
Diagnostic Trouble Code IndexDTC: Speed Control Module (CCM)
Diagnostic Trouble Code IndexDTC: Steering Column Lock Module (VIM)
Diagnostic Trouble Code IndexDTC: Television Module (TVM)
Diagnostic Trouble Code IndexDTC: Tire Pressure Monitoring System Module (TPM)
Diagnostic Trouble Code IndexDTC: Touch Screen Display (FCDIM)
Diagnostic Trouble Code IndexDTC: Transmission Control Module (TCM) 6 speed
(6HP26)
Diagnostic Trouble Code IndexDTC: Transmission Control Module (TCM) 6 speed
(6HP28)
Diagnostic Trouble Code IndexDTC: Transmission Control Module (TCM) 8 speed
(8HP70)
Diagnostic Trouble Code IndexDTC: Transmission Shift Module (GSM)
100-01: Identification Codes
Description and Operation
Identification Codes
100-02: Jacking and Lifting
Description and Operation
Jacking
Lifting
100-04: Noise, Vibration and Harshness
Description and Operation
Noise, Vibration and Harshness
Diagnosis and Testing
Noise, Vibration and Harshness
General Procedures
Exhaust System Neutralizing
100-11: Vehicle Transportation Aids and Vehicle Storage
Description and Operation
New Vehicle Storage
New Vehicle Storage Form
101: Pre-Delivery Information
101-01: Pre-Delivery Inspection Manual
Description and Operation
Introduction
Preliminary
Vehicle Interior
Vehicle Exterior
Road Test
Quality Assurance Checks
101-02: Showroom Preparation
Description and Operation
Showroom Preparation
2: Chassis
204: Suspension
204-00: Suspension System - General Information
Specification
Diagnosis and Testing
Suspension System
General Procedures
Camber and Caster Adjustment
Four Wheel Alignment
Front Toe Adjustment
Rear Toe Adjustment
Front Wheel Bearing and Wheel Hub Runout Check - Vehicles With: High Performance
Brakes
Front Wheel Bearing and Wheel Hub Runout Check - Vehicles With: Standard Brakes
Rear Wheel Bearing and Wheel Hub Runout Check
Steering Wheel Vibration/Shimmy While Driving
Wheel and Tire Assembly Balancing
204-01: Front Suspension
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Front Suspension
Removal and Installation
Front Shock Absorber
Front Lower Arm
Rear Lower Arm
Rear Lower Arm Bush
Shock Absorber Bushing
Front Stabilizer Bar - TD4 2.2L Diesel/TDV6 3.0L Diesel
Front Stabilizer Bar Link
Stabilizer Bar Link Bushing
Left Upper Arm
Right Upper Arm
Front Wheel Bearing and Wheel Hub - TD4 2.2L Diesel/TDV6 3.0L Diesel /V8 N/A 5.0L
Petrol/V8 S/C 5.0L Petrol
Wheel Knuckle
Front Lower Arm Bush
Front Stabilizer Bar Bush - TD4 2.2L Diesel/TDV6 3.0L Diesel
204-02: Rear Suspension
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Rear Suspension
Removal and Installation
Lower Arm
Shock Absorber and Spring Assembly
Shock Absorber Lower Bushing
Rear Stabilizer Bar
Rear Wheel Bearing
Upper Arm
Disassembly and Assembly
Shock Absorber and Spring Assembly
204-04: Wheels and Tires
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Wheels and Tires
Tire Pressure Monitoring System
Removal and Installation
Tire Low Pressure Sensor
Tire Pressure Monitoring System Front Antenna
Tire Pressure Monitoring System Rear Antenna
Tire Pressure Monitoring System Module
Tire Pressure Monitoring System Receiver
Wheel and Tire
204-05: Vehicle Dynamic Suspension
Diagnosis and Testing
Vehicle Dynamic Suspension
Removal and Installation
Adaptive Damping Module
Front Suspension Vertical Accelerometer
Rear Suspension Vertical Accelerometer
204-06: Ride and Handling Optimization
Description and Operation
Component Location
Overview
System Operation and Component Description
205: Driveline
205-00: Driveline System - General Information
Diagnosis and Testing
Driveline System
General Procedures
Driveline Angle Inspection
Driveshaft to Rear Differential Disconnection
205-01: Driveshaft
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Driveshaft
General Procedures
Driveshaft Runout and Balancing
Removal and Installation
Driveshaft - TDV6 3.0L Diesel
205-02: Rear Drive Axle/Differential
Specification - TD4 2.2L Diesel/TDV6 3.0L Diesel
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Rear Drive Axle and Differential
General Procedures
Differential Draining and Filling - TD4 2.2L Diesel/TDV6 3.0L Diesel
Removal and Installation
Differential - TD4 2.2L Diesel/TDV6 3.0L Diesel
Differential Front Bush - TD4 2.2L Diesel/TDV6 3.0L Diesel
Differential Locking Motor
Rear Halfshaft Seal
Drive Pinion Seal
205-05: Rear Drive Halfshafts
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Rear Drive Halfshafts
Removal and Installation
Rear Halfshaft - TD4 2.2L Diesel/TDV6 3.0L Diesel /V8 N/A 5.0L Petrol/V8 S/C 5.0L
Petrol
Inner Constant Velocity Joint Boot
Outer Constant Velocity Joint Boot
206: Brake System
206-00: Brake System - General Information
Specification - TDV6 3.0L Diesel /V8 N/A 5.0L Petrol/V8 S/C 5.0L Petrol
Diagnosis and Testing
Brake System
General Procedures
Brake Disc Runout Check
Brake System Bleeding
Front Brake Disc Runout Check - With Wheel On - Vehicles With: High Performance
Brakes
Front Brake Disc Runout Check - With Wheel On - Vehicles With: Standard Brakes
Rear Brake Disc Runout Check - With Wheel On
206-03B: Front Disc Brake - TD4 2.2L Diesel/TDV6 3.0L Diesel /V8 N/A 5.0L Petrol/V8 S/C
5.0L Petrol
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Removal and Installation
Brake Caliper - Vehicles With: High Performance Brakes
Brake Caliper - Vehicles With: Standard Brakes
Brake Disc - Vehicles With: High Performance Brakes
Brake Disc - Vehicles With: Standard Brakes
Brake Pads - Vehicles With: High Performance Brakes
Brake Pads - Vehicles With: Standard Brakes
Brake Disc Shield - Vehicles With: Standard Brakes
Brake Disc Shield - Vehicles With: High Performance Brakes
206-04B: Rear Disc Brake - TD4 2.2L Diesel/TDV6 3.0L Diesel /V8 N/A 5.0L Petrol/V8 S/C
5.0L Petrol
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Removal and Installation
Brake Caliper - Vehicles With: High Performance Brakes
Brake Caliper - Vehicles With: Standard Brakes
Brake Disc - Vehicles With: High Performance Brakes
Brake Disc - Vehicles With: Standard Brakes
Brake Pads - Vehicles With: High Performance Brakes
Brake Pads - Vehicles With: Standard Brakes
Brake Disc Shield
206-05: Parking Brake and Actuation
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Parking Brake
General Procedures
Parking Brake Cable Tension Release
Removal and Installation
Left Parking Brake Cable - TD4 2.2L Diesel/TDV6 3.0L Diesel /V8 N/A 5.0L Petrol/V8
S/C 5.0L Petrol
Right Parking Brake Cable - TD4 2.2L Diesel/TDV6 3.0L Diesel /V8 N/A 5.0L Petrol/V8
S/C 5.0L Petrol
Parking Brake Module
Parking Brake Switch
Parking Brake Release Actuator
206-06: Hydraulic Brake Actuation
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Hydraulic Brake Actuation
Removal and Installation
Brake Master Cylinder
206-07: Power Brake Actuation
Specification
Description and Operation
Component Location
Overview
Diagnosis and Testing
Power Brake System
Removal and Installation
Brake Booster
Brake Vacuum Pump - TDV6 3.0L Diesel
206-09: Anti-Lock Control - Stability Assist
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Anti-Lock Control - Stability Assist
Removal and Installation
Anti-Lock Brake System Control Module
Front Wheel Speed Sensor
Hydraulic Control Unit
Rear Wheel Speed Sensor
Steering Angle Sensor Module
Yaw Rate Sensor and Accelerometer
211: Steering System
211-00: Steering System - General Information
Specification
Diagnosis and Testing
Steering System
General Procedures
Power Steering System Bleeding
Power Steering System Flushing
Power Steering System Filling - TDV6 3.0L Diesel
211-02: Power Steering
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Power Steering
Removal and Installation
Steering Gear - RWD
Power Steering Fluid Reservoir - TDV6 3.0L Diesel
Power Steering Pump - TDV6 3.0L Diesel
Power Steering Pressure Line and Return Line Assembly
211-03: Steering Linkage
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Steering Linkage
Removal and Installation
Tie Rod
211-04: Steering Column
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Steering Column
Removal and Installation
Steering Column
Steering Column Flexible Coupling
Steering Wheel
211-05: Steering Column Switches
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Steering Column Switches
Removal and Installation
Hazard Flasher Switch
Left Steering Column Multifunction Switch
Right Steering Column Multifunction Switch
Steering Column Lock Actuator
3: Powertrain
303: Engine
303-00: Engine System - General Information
Diagnosis and Testing
Engine - TDV6 3.0L Diesel
General Procedures
Bearing Inspection
Camshaft Bearing Journal Diameter
Camshaft End Play
Camshaft Lobe Lift
Camshaft Surface Inspection
Connecting Rod Cleaning
Connecting Rod Large End Bore
Cylinder Bore Out-of-Round
Exhaust Manifold Cleaning and Inspection
Leakage Test Using Smoke Test Equipment
Piston Inspection
Piston Pin Diameter
Piston Pin to Bore Diameter
Piston Ring End Gap
Piston Ring-to-Groove Clearance
Valve Spring Free Length
Valve Stem Diameter
Cylinder Head Gasket Selection - TDV6 3.0L Diesel
Cylinder Head Distortion
Cylinder Compression Test - TDV6 3.0L Diesel
Thread repair
Cylinder Block Distortion Measurement
303-01B: Engine - TDV6 3.0L Diesel
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Engine
General Procedures
Engine Oil Draining and Filling
Engine Oil Vacuum Draining and Filling
Removal and Installation
Left Camshaft
Right Camshaft
Camshaft Front Seal
Camshaft Rear Seal
Crankshaft Front Seal
Crankshaft Pulley
Crankshaft Rear Seal
Crankshaft Vibration Damper
Left Cylinder Head
Right Cylinder Head
Left Engine Mount
Right Engine Mount
Left Exhaust Manifold
Right Exhaust Manifold
Exhaust Manifold Cross-over Pipe
Flexplate
Oil Filter Element
Oil Pan
Oil Pan Extension
Oil Pump
Timing Belt
Timing Cover
Left Valve Cover
Right Valve Cover
Removal
Engine
Disassembly
Long/Stripped Engine Assembly Renew
Short Engine Assembly Renew
Assembly
Long/Stripped Engine Assembly Renew
Installation
Engine
303-03B: Engine Cooling - TDV6 3.0L Diesel
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Engine Cooling
General Procedures
Cooling System Draining, Filling and Bleeding
Cooling System Partial Draining, Filling and Bleeding
Cooling System Partial Draining and Vacuum Filling
Cooling System Pressure Test
Removal and Installation
Auxiliary Radiator
Coolant Expansion Tank
Coolant Pump
Electric Cooling Fan and Shroud
Radiator
Thermostat
303-04C: Fuel Charging and Controls - TDV6 3.0L Diesel
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Fuel Charging and Controls
General Procedures
Fuel Injection Component Cleaning
Removal and Installation
Fuel Injection Pump
Fuel Injector
Left Fuel Rail
Right Fuel Rail
Intake Air Shutoff Throttle
303-04D: Fuel Charging and Controls - Turbocharger - TDV6 3.0L Diesel
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Turbocharger
Removal and Installation
Left Turbocharger
Right Turbocharger
Turbocharger Bypass Valve
Fixed Vane Turbocharger Actuator
303-05B: Accessory Drive
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Accessory Drive
Removal and Installation
Accessory Drive Belt
Accessory Drive Belt Pulley
Accessory Drive Belt Tensioner
Fuel Injection Pump Pulley
Rear End Accessory Drive
303-06B: Starting System - TDV6 3.0L Diesel
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Starting System
Starting System - Vehicles With: Smart Key
Removal and Installation
Starter Motor
303-07D: Glow Plug System - TDV6 3.0L Diesel
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Glow Plug System
Removal and Installation
Glow Plugs - TDV6 3.0L Diesel
303-08B: Engine Emission Control - TDV6 3.0L Diesel
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Engine Emission Control
Removal and Installation
Crankcase Vent Oil Separator
Left Exhaust Gas Recirculation Valve
Exhaust Gas Recirculation Valve Outlet Tube
Right Exhaust Gas Recirculation Valve
303-12B: Intake Air Distribution and Filtering - TDV6 3.0L Diesel
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Intake Air Distribution and Filtering
Removal and Installation
Air Cleaner
Air Cleaner Element
Charge Air Cooler
303-14A: Electronic Engine Controls - TDV6 3.0L Diesel
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Electronic Engine Controls
Removal and Installation
Camshaft Position Sensor
Crankshaft Position Sensor
Crankshaft Position Sensor Ring
Diesel Particulate Filter Differential Pressure Sensor
Engine Coolant Temperature Sensor
Engine Control Module
Engine Oil Level Sensor
Engine Oil Pressure Sensor
Right Exhaust Gas Temperature Sensor
Heated Oxygen Sensor
Intake Air Temperature Sensor
Manifold Absolute Pressure Sensor
Mass Air Flow Sensor
Oil Temperature Sensor
Post Catalytic Converter Temperature Sensor
Post DPF Exhaust Gas Temperature Sensor
Pre Catalytic Converter Temperature Sensor
Pre DPF Exhaust Gas Temperature Sensor
307: Automatic Transmission/Transaxle
307-01C: Automatic Transmission/Transaxle - TD4 2.2L Diesel/TDV6 3.0L Diesel
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
General Procedures
Transmission Fluid Level Check
Transmission Fluid Drain and Refill
Removal and Installation
Input Shaft Seal
Extension Housing Seal - TDV6 3.0L Diesel
Transmission Control Module and Main Control Valve Body - TDV6 3.0L Diesel
Transmission Fluid Pan, Gasket and Filter
Transmission Support Insulator - TDV6 3.0L Diesel
Transmission, Transmission Fluid Cooler and Transmission Fluid Cooler Tubes - TDV6
3.0L Diesel
Transmission and Transmission Fluid Cooler - TDV6 3.0L Diesel
Removal
Transmission - TDV6 3.0L Diesel
Installation
Transmission - TDV6 3.0L Diesel
307-02B: Transmission/Transaxle Cooling - TD4 2.2L Diesel/TDV6 3.0L Diesel /V8 N/A 5.0L
Petrol/V8 S/C 5.0L Petrol
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Transmission Cooling
Removal and Installation
Transmission Fluid Cooler - TDV6 3.0L Diesel
Transmission Fluid Cooler Pipes - TDV6 3.0L Diesel
307-05C: Automatic Transmission/Transaxle External Controls - TD4 2.2L Diesel/TDV6 3.0L
Diesel
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Removal and Installation
Transmission Control Switch
Transmission Control Switch Knob
Emergency Park Release Lever
Upshift Paddle Switch
Downshift Paddle Switch
309: Exhaust System
309-00B: Exhaust System - TDV6 3.0L Diesel
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Component Location
System Operation and Component Description
Diagnosis and Testing
Diesel Particulate Filter
Exhaust System
Removal and Installation
Catalytic Converter
Diesel Particulate Filter
Exhaust System
Front Muffler
Rear Muffler
310: Fuel System - General Information
310-00: Fuel System - General Information
Specification
General Procedures
Fuel Tank Draining
Low-Pressure Fuel System Bleeding - TDV6 3.0L Diesel
Quick Release Coupling
Quick Release Coupling - Push Connect
Spring Lock Couplings
310-01B: Fuel Tank and Lines - TDV6 3.0L Diesel
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Fuel Tank and Lines
Removal and Installation
Fuel Cooler
Fuel Filter
Fuel Level Sensor
Fuel Pump Driver Module
Fuel Tank
Fuel Tank Filler Pipe
310-02: Acceleration Control
Specification
Diagnosis and Testing
Acceleration Control
Removal and Installation
Accelerator Pedal
310-03B: Speed Control - TDV6 3.0L Diesel
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Speed Control
General Procedures
Adaptive Speed Control Module Adjustment
Removal and Installation
Speed Control Deactivator Switch
Speed Control Switch
Adaptive Speed Control Module
4: Electrical
412: Climate Control System
412-00: Climate Control System - General Information
Specification
Diagnosis and Testing
Climate Control System
General Procedures
Air Conditioning System Recovery, Evacuation and Charging
Contaminated Refrigerant Handling
Electronic Leak Detection
Fluorescent Dye Leak Detection
Inspection and Assembly Requirements
Manifold Gauge Set Connection
Refrigerant Oil Adding - TD4 2.2L Diesel/TDV6 3.0L Diesel /V8 N/A 5.0L Petrol/V8 S/C
5.0L Petrol
Refrigerant System Tests
Air Conditioning Compressor Commissioning
Air Conditioning System Flushing
412-01: Climate Control
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Component Location
Overview
System Operation and Component Description
Component Location
Overview
System Operation and Component Description
Component Location
Overview
System Operation and Component Description
Removal and Installation
Ambient Air Temperature Sensor
Blower Motor
Blower Motor Control Module
Center Registers
Climate Control Assembly
Climate Control Module
Defrost Vent/Register Blend Door Actuator
Driver Side Register
Evaporator
Floor Console Register
Footwell Vent/Duct Blend Door Actuator
Heater Core
Heater Core and Evaporator Housing
Instrument Panel Register Trim Panel
In-Vehicle Temperature Sensor
Passenger Side Register
Pollen Filter
Recirculation Blend Door Actuator
Sunload Sensor
Thermostatic Expansion Valve
Side Vent Clutch
412-02: Auxiliary Climate Control
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Removal and Installation
Auxiliary Coolant Flow Pump
Electric Booster Heater
412-03: Air Conditioning
Specification
Diagnosis and Testing
Air Conditioning
Removal and Installation
Air Conditioning Compressor - TDV6 3.0L Diesel
Condenser Core - TDV6 3.0L Diesel
Pressure Cutoff Switch
Receiver Drier - TD4 2.2L Diesel/TDV6 3.0L Diesel
413: Instrumentation and Warning Systems
413-01: Instrument Cluster
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Instrument Cluster
Removal and Installation
Instrument Cluster
Instrument Cluster Lens
413-06: Horn
Specification
Removal and Installation
Horn
Horn Switch
413-08: Information and Message Center
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Information and Message Center
413-09: Warning Devices
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Warning Devices
413-13: Parking Aid
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Parking Aid
Rear View Camera
Removal and Installation
Front Inner Parking Aid Sensor
Front Outer Parking Aid Sensor
Parking Aid Camera
Parking Aid Module
Rear Parking Aid Sensor
414: Battery and Charging System
414-00: Battery and Charging System - General Information
Description and Operation
Quiescent Drain
Battery Report Form – In Service Batteries Only
Diagnosis and Testing
Charging System
General Procedures
Battery Support Unit Connection Procedure
414-01: Battery, Mounting and Cables
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Battery
Battery Diagnostics - 12 Volt Midtronics EXP-1080 JLR Hand-Held Battery Diagnostic
Tool
Battery Diagnostics - 12 Volt Midtronics GRX-3080 JLR Diagnostic Battery Charger
Battery Diagnostics - 12 Volt Midtronics GR8-1180 JLR Diagnostic Battery Charger
Low Battery Diagnostics
Flat Battery Diagnostics
General Procedures
Startup Battery Disconnect and Connect
Removal and Installation
Battery
414-02B: Generator and Regulator - TDV6 3.0L Diesel
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Removal and Installation
Generator
415: Information and Entertainment Systems
415-00: Information and Entertainment System - General Information
Description and Operation
Navigation System Map Updates
Diagnosis and Testing
Information and Entertainment System
Cellular Phone
Navigation System
415-01A: Information and Entertainment System
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Component Location
Overview
System Operation and Component Description
Overview
Component Location
System Operation and Component Description
Component Location
Overview
System Operation and Component Description
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Information and Entertainment System
Speakers
Removal and Installation
Audio Unit
Audio Unit Antenna Amplifier
Audio and Climate Control Assembly
Front Door Speaker
Information and Entertainment Display
Information and Entertainment Module
Instrument Panel Speaker
Rear Door Speaker
Steering Wheel Audio Controls
Subwoofer Amplifier
Subwoofer Speaker
Satellite Radio Tuner
Navigation Control Module with SD Memory Card
415-01B: Information and Entertainment System - DTC: Audio Input Control Module
Diagnosis and Testing
Audio Input Control Modulenull
417: Lighting
417-01: Exterior Lighting
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Headlamps
General Procedures
Headlamp Adjustment
Removal and Installation
Approach Lamp
Headlamp Assembly
Headlamp Leveling Front Sensor
Headlamp Leveling Module
Headlamp Leveling Rear Sensor
High Mounted Stoplamp
Rear Fog Lamp
Rear Lamp Assembly
Side Repeater Lamp Bulb
Stoplamp Switch
417-02: Interior Lighting
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Interior Lighting
417-04: Daytime Running Lamps
Description and Operation
Overview
418: Electrical Distribution
418-00: Module Communications Network
Description and Operation
Overview
System Operation and Component Description
Diagnosis and Testing
Communications Network
Removal and Installation
Auxiliary Junction Box
Central Junction Box
418-02: Wiring Harnesses
Description and Operation
Wiring Harness
Wiring Harness Overlay
General Procedures
Wiring Harness Repair
Removal and Installation
Luggage Compartment Lid Wiring Harness
419: Electronic Feature Group
419-01A: Anti-Theft - Active
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Anti-Theft - Active
Removal and Installation
Anti-Theft Alarm Horn
419-01B: Anti-Theft - Passive
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Anti-Theft - Passive
419-05: Telematics
Diagnosis and Testing
Telematics
419-07: Navigation System
Diagnosis and Testing
Navigation System
Removal and Installation
Navigation System Antenna
Navigation System Module
419-08: Cellular Phone
Removal and Installation
Bluetooth Module
419-10: Multifunction Electronic Modules
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Driver Door Module
Remote Keyless Entry Module
Passenger Door Module
Removal and Installation
Driver Door Module
Driver Seat Module
Passenger Door Module
Rear Door Module
5: Body and Paint
501: Body and Paint
501-02: Front End Body Panels
Specification
Removal and Installation
Hood
Engine Undershield
Cowl Vent Screen
Engine Rear Undershield
Fender Splash Shield
Radiator Splash Shield
Secondary Bulkhead Center Panel - TDV6 3.0L Diesel /V6 N/A 3.0L Petrol/V8 N/A 5.0L
Petrol/V8 S/C 5.0L Petrol
Secondary Bulkhead Left Panel - TDV6 3.0L Diesel /V8 N/A 5.0L Petrol/V8 S/C 5.0L
Petrol
Secondary Bulkhead Right Panel - TDV6 3.0L Diesel /V8 N/A 5.0L Petrol/V8 S/C 5.0L
Petrol
501-03: Body Closures
Removal and Installation
Front Door
Fuel Filler Door
Fuel Filler Door Assembly
Luggage Compartment Lid
Rear Door
501-05: Interior Trim and Ornamentation
Specification
Removal and Installation
A-Pillar Trim Panel
B-Pillar Lower Trim Panel
B-Pillar Upper Trim Panel
C-Pillar Lower Trim Panel
C-Pillar Trim Panel
Cowl Side Trim Panel
Engine Cover - TDV6 3.0L Diesel
Front Door Trim Panel
Front Scuff Plate Trim Panel
Instrument Panel Speaker Grille
Headliner
Loadspace Scuff Plate Trim Panel
Loadspace Trim Panel
Left Loadspace Trim Panel
Right Loadspace Trim Panel
Luggage Compartment Lid Trim Panel
Parcel Shelf
Rear Door Trim Panel
Rear Scuff Plate Trim Panel
Sun Visor
Sun Visor Vanity Mirror
501-08: Exterior Trim and Ornamentation
Specification
Removal and Installation
Radiator Grille
Luggage Compartment Lid Moulding
Front Fender Moulding
Rocker Panel Moulding
501-09: Rear View Mirrors
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Rear View Mirrors
Removal and Installation
Exterior Mirror
Exterior Mirror Cover
Exterior Mirror Glass
Exterior Mirror Motor
Interior Rear View Mirror
501-10: Seating
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Seat Cover Inspection
Diagnosis and Testing
Heater Mats
Seats - Vehicles With: Climate Controlled Seats
Seats
General Procedures
Seat Smoothing
Removal and Installation
Front Row Seat
Front Row Seat Backrest
Front Row Seat Backrest Cover
Front Seat Bolster
Front Seat Bolster Pump
Front Row Seat Cushion Cover
Front Seat Track Motor
Lumbar Assembly
Memory Seat Position Switch
Seat Base - Vehicles With: Manual Adjustment
Seat Base - Vehicles Without: Manual Adjustment
Rear Seat Backrest Cover
Rear Seat Cushion
Front Seat Height Adjustment Motor
Front Row Seat Switchpack
Front Seat Head Restraint Motor
Rear Seat Bolster
Front Row Seat Backrest Cover Trim Panel
501-11: Glass, Frames and Mechanisms
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Glass, Frames and Mechanisms
Fixed Window Glass
General Procedures
Door Window Motor Initialization
Removal and Installation
Driver Door Window Control Switch
Front Door Window
Front Door Window Regulator and Motor
Rear Door Fixed Window Glass
Rear Door Window Glass
Rear Door Window Regulator and Motor
Rear Window Glass
Windshield
Door Window Regulator Motor
501-12: Instrument Panel and Console
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Removal and Installation
Floor Console
Floor Console Cup Holder
Floor Console Double Cup Holder
Floor Console Side Trim Panel
Glove Compartment
Instrument Panel Console
Instrument Panel Lower Trim Panel
Overhead Console
501-14: Handles, Locks, Latches and Entry Systems
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Locks, Latches and Entry Systems
General Procedures
Exterior Door Handle Assembly
Smart Key Housing Renew
Removal and Installation
Door Lock Cylinder Cover
Exterior Front Door Handle
Exterior Luggage Compartment Lid Release Switch
Exterior Rear Door Handle
Front Door Latch
Front Door Lock Cylinder
Interior Front Door Handle
Luggage Compartment Lid Latch Actuator
Luggage Compartment Lid Lock Cylinder
Luggage Compartment Lid Latch
Rear Door Latch
Hood Latch
501-16: Wipers and Washers
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Wipers and Washers
Removal and Installation
Headlamp Washer Jet
Headlamp Washer Pump
Rain Sensor
Windshield Washer Reservoir
Windshield Wiper Motor
Windshield Wiper Pivot Arm
Windshield Washer Pump
501-17: Roof Opening Panel
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Roof Opening Panel
General Procedures
Roof Opening Panel Alignment
Motor Synchronization
Removal and Installation
Roof Opening Panel Front Drain Hose
Roof Opening Panel Frame
Roof Opening Panel Glass
Roof Opening Panel Motor
Roof Opening Panel Rear Drain Hose
Roof Opening Panel Weatherstrip
501-19: Bumpers
Specification
Removal and Installation
Front Bumper
Front Bumper Cover
Front Bumper Cover Insert
Rear Bumper Cover
Rear Bumper
501-20A: Seatbelt System
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Seatbelt System
Removal and Installation
Front Row Safety Belt Buckle
Front Safety Belt Retractor
Rear Center Safety Belt Retractor
Rear Safety Belt Buckle
Rear Safety Belt Retractor
Safety Belt Shoulder Height Adjuster
501-20B: Supplementary Restraint System
Specification
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Airbag and Safety Belt Pretensioner Supplemental Restraint System
General Procedures
Airbag Disposal
Removal and Installation
B-Pillar Side Impact Sensor
Clockspring
C-Pillar Side Impact Sensor
Crash Sensor
Driver Airbag Module
Occupant Classification Sensor
Passenger Airbag Module
Restraints Control Module
Side Airbag Module
Side Air Curtain Module
501-20C: Pedestrian Protection System
Description and Operation
Component Location
Overview
System Operation and Component Description
Diagnosis and Testing
Pedestrian Protection System
Removal and Installation
Pedestrian Impact Sensor
Left Pedestrian Protection Hood Actuator
Right Pedestrian Protection Hood Actuator
Pedestrian Protection Module
501-25A: Body Repairs - General Information
Body Repair Procedure Graphic Key
Description and Operation
Body Repairs
Adhesives, Fixings and Consumables
General Procedures
Body Closure / Noise Vibration and Harshness Sealing
501-25B: Body Repairs - Corrosion Protection
Description and Operation
Corrosion Protection
501-25C: Body Repairs - Water Leaks -
Description and Operation
Water Leaks
501-26: Body Repairs - Vehicle Specific Information and Tolerance Checks
Description and Operation
Body and Frame
501-27: Front End Sheet Metal Repairs
Description and Operation
Front End Sheet Metal
Removal and Installation
Fender Apron Closing Panel Front Section
Fender Apron Panel
Fender Apron Panel Closing Panel
Fender Apron Panel Front Extension
Fender Apron Panel Front Section
Front Bumper Mounting
Front Fender
Front Fender Support Bracket
Front Side Member
Front Side Member and Suspension Top Mount Assembly
Front Side Member Closing Panel
Front Side Member Closing Panel Section
Front Side Member Section
Front Wheelhouse Section
Hood Latch Panel
Hood Latch Panel Mounting Bracket
501-28: Roof Sheet Metal Repairs
Description and Operation
Roof
Removal and Installation
Roof Panel - Vehicles With: Sliding Roof Opening Panel
Roof Panel - Vehicles Without: Sliding Roof Opening Panel
501-29: Side Panel Sheet Metal Repairs
Description and Operation
Side Panel Sheet Metal
Removal and Installation
A-Pillar Outer Panel
A-Pillar Reinforcement
B-Pillar Inner Panel
B-Pillar Reinforcement
Front Door Skin Panel
Rear Door Skin Panel
Rocker Panel
Rocker Panel and B-Pillar Outer Panel
Rocker Panel Front Section
Rocker Panel Inner Reinforcement
Rocker Panel Rear Section
501-30: Rear End Sheet Metal Repairs
Description and Operation
Rear End Sheet Metal
Removal and Installation
Back Panel
Quarter Panel
Quarter Panel Lower Extension
Rear Bumper Mounting
Rear Floor Side Extension
Rear Side Member Closing Panel Section
Rear Side Member Rear Extension
Rear Wheelhouse Outer
Spare Wheel Well
502: Frame and Mounting
502-00: Uni-Body, Subframe and Mounting System
Specification
Removal and Installation
Front Subframe - TDV6 3.0L Diesel
Rear Subframe - TD4 2.2L Diesel/TDV6 3.0L Diesel
Rear Subframe Rear Bush - TD4 2.2L Diesel/TDV6 3.0L Diesel /V8 N/A 5.0L Petrol/V8
S/C 5.0L Petrol
Slide Hammer 100-012
Kit - Pinion Repair JLR-205-1031
Published: 11-May-2011

2012.0 XF (X250), 100-00

General Information

About This Manual (G836098)


DESCRIPTION AND OPERATION
Introduction

This manual covers diagnosis and testing and repair procedures.

It is structured into groups and sections, with specific system sections collected together under their relevant group.

A group covers a specific portion of the vehicle. The manual is divided into five groups, General Information,
Chassis, Powertrain, Electrical and Body and Paint. The number of the group is the first number of a section number.

Within Etis, the navigation tree will list the groups. After selecting a group the navigation tree will then list the
sections within that group. Each section has a contents list detailing Specifications, Description and Operation,
Diagnosis and Testing, General Procedures, Disassembly and Assembly, Removal and Installation.

References to left-hand (LH) and right-hand (RH)


All LH and RH references to the vehicle are taken from a position sitting in the driver seat looking forward.

Vehicle LH and RH definition

Item Description
1 LH
2 RH

All LH and RH references to the engine are taken from a position at the flywheel looking towards the crankshaft
front pulley.

Powertrain LH and RH definition

Item Description
1 front
2 right
3 rear
4 left
How to use Repair Procedures

This manual has been written in a format that is designed to meet the needs of technicians worldwide. It provides
general descriptions for accomplishing repair work with tested and effective techniques.

Important Safety Instructions


Appropriate service methods and correct repair procedures are essential for the safe, reliable operation of all motor
vehicles as well as the personal safety of the individual carrying out the work.

Anyone who departs from the instructions provided in this manual must first establish that personal safety or vehicle
integrity is not compromised by the choice of method, tools or components.

Warnings, Cautions and Notes in This Manual


WARNING:

Warnings are used to indicate that failure to follow a procedure correctly may result in personal injury.

CAUTION:
Cautions are used to indicate that failure to follow a procedure correctly may result in damage to the vehicle or
equipment being used.

NOTE:

Notes are used to provide additional essential information required to carry out a complete and satisfactory repair.

Generic warnings or cautions are in their relevant description and operation procedure within section 100-00. If the
generic warnings or cautions are required for a procedure, there will be a referral to the appropriate description and
operation procedure.

If a warning, caution or note only applies to one step, it is placed at the beginning of the specific step.

Trustmark Authoring Standards (TAS) Repair Procedures


NOTE:

TAS style procedures can be identified by steps that have no accompanying step text and the magenta color of the
electrical connectors and fasteners such as nuts, bolts, clamps or clips.

A TAS removal and installation procedure uses a sequence of color illustrations to indicate the order to be followed
when removing/disassembling or installing/assembling a component.

Many of the TAS procedures will have the installation information within the removal steps. These procedures will
have the following note at the beginning of the procedure:

NOTE:

Removal steps in this procedure may contain installation details.

Reuse of fasteners and seals and gaskets

The following list details the general policy for the reuse of fasteners and seals and gaskets.

Types of self-locking nuts and bolts


NOTE:

There are more types of self-locking fasteners available than shown in following illustration.
Item Description
1 Completely coated self-locking bolt
2 Partially coated self-locking bolt
3 Self-locking bolt with a locking washer
4 Self-locking nut with a plastic locking insert
5 Self-locking nut with thread deformation (3 dents)
6 Self-locking nut with thread deformation (squeeze of thread to oval shape)
7 Self-locking nut with integrated locking ring

All types of seals and gaskets must be discarded and new seals and gaskets installed unless otherwise stated
within the procedure.
Nuts and bolts with a chemical coating for locking and/or sealing and/or antiseize must be discarded unless the
procedure advises to reapply the coating with a specified material.
Nuts and bolts with a mechanical locking such as thread inserts, thread deformation or locking washers must
be discarded and new nuts and bolts installed unless otherwise stated within the procedure.
Torque to yield bolts must be discarded and new torque to yield bolts installed unless otherwise stated within
the procedure, recognizable by a tightening torque with more than one stage together with a torque angle.

Specification data

Specification procedures will only contain technical data that is not already part of a repair procedure.

Sequence of tasks

If components must be removed or installed in a specific sequence, the sequence will be identified numerically in a
graphic and the corresponding text will be numbered accordingly.

Special Tools, Equipment, Materials and Torque Figures

Special tools will be shown with the tool numbers in the illustration. The special tool numbers, general equipment,
materials and torque figures used for the procedure step will be shown in the text column.
TAS Graphics

Colors used in the graphic are as follows:

Blue - Component to be removed/installed or disassembled/assembled.


Green and Brown - Additional components that need to be removed/installed or disassembled/assembled prior
to the target component.
Yellow - Component that is touched or affected in a way but remains in the vehicle. It may be detached,
attached, moved, modified, checked, adjusted etc.
Magenta - Electrical connectors and fasteners such as nuts, bolts, clamps and clips.
Pale Blue - Special tool(s) and general equipment.

One illustration may have multiple steps assigned to it.

Numbered pointers are used to indicate the number of electrical connectors and fasteners such as nuts, bolts, clamps
and clips.

Items in the illustration can be transparent or use cutouts to show hidden details.
TAS Symbols

Symbols are used inside the graphics and in the text area to enhance the information display. The following
paragraphs describe the various types and categories of symbols. For additional information, refer to: Symbols
Glossary (100-00 General Information, Description and Operation).

Prohibition symbols advise on prohibited actions to either avoid damage or health and safety related risks. These
symbols are

Health and Safety symbols recommend the use of particular protection equipment to avoid or at least reduce the risk
or severity of possible injuries.
Warning symbols are used to indicate potential risks resulting from a certain component or area.

Instruction symbols are used to apply sealer, lubricant, weight, tape or cleaning detergent to a component.
Location symbols are used to show the location of a component or system within the vehicle.

Gearshift lever or selector lever position symbols are used to show which gearshift lever or selector lever position is
to be set.
Pointer symbols are used to draw attention to components and give special instructions such as a required sequence
or number of components. The number of components is reflected by the value inside the luty arrow. A sequence
number is located inside the circle. Numbers inside circles are also used to allocate special information such as
tightening torques or chemicals to a particular component.

Movement arrows are used to show three dimensional or rotational movements. These movements can include
specific values inside the symbol if required.
Standard tool symbols recommend the use of certain standard tools. These tools can include dimension values if
required.

The following graphic illustrates a set of symbols that are used to provide detailed information on where to apply a
material.
Measurement symbols provide detailed information on where to carry out a specific measurement. These symbols
can include specific values if required.

How to use Diagnosis and Testing procedures


Inspection and Verification

Visual Inspection Charts, Symptom Charts and other information charts (such as diagnostic routines) or supplement
test procedures with technical specifications will navigate the user to a specific test procedure.

Symptom Chart

The symptom chart indicates symptoms, sources and actions to address a condition.

Pinpoint Tests
For electrical systems, pinpoint test steps are used to identify the source of a concern in a logical, step-by-step
manner. Pinpoint tests have two columns: CONDITIONS and DETAILS/RESULTS/ACTIONS.

The CONDITIONS column is used exclusively for graphics and icons (with or without captions) and the
DETAILS/RESULTS/ACTIONS column provides direction to another test step or specific corrective actions.

The boxed numbers indicate the order in which the described action is to be carried out.

Component Tests

A component test is used when a component is tested in multiple pinpoint tests, or if a procedure is too complicated
to be formatted within a single page of the pinpoint test.

Graphics

Test graphics show the measurement or test to be carried out in a test step.

A representative tester graphic is used for voltmeters and ohmmeters.

If multiple measurements are made in a single graphic, the test leads are drawn with a solid line until the test lead
splits to indicate the multiple measurements, at which point dashed lines are used.

Breakout box type testers are represented by a double circle test pin. Test pins are labeled with the pin number.
Published: 11-May-2011

2012.0 XF (X250), 100-00

General Information

Application and Use of Specifications (G61151)


DESCRIPTION AND OPERATION
Torque Specifications

Torque specifications are shown in the torque specifications chart located at the front of the relevant section.
Published: 11-May-2011

2012.0 XF (X250), 100-00

General Information

Battery and Battery Charging Health and Safety


Precautions (G548994)
DESCRIPTION AND OPERATION
WARNINGS:

Batteries contain sulphuric acid, avoid contact with skin, eyes or clothing. Wear safety goggles when working
near the battery to protect against possible splashing of the acid solution.

EYE CONTACT: If acid comes into contact with the eyes, flush immediately with plenty of running water for
a minimum of 15 minutes. Seek immediate medical attention.

SKIN CONTACT: If acid comes into contact with the skin, flush immediately with plenty of running water
for a minimum of 15 minutes. Seek immediate medical attention.

SWALLOWED: If acid is swallowed, rinse the mouth with plenty of water and then drink plenty of water or
milk. Do not induce vomiting. Seek immediate medical attention.

Batteries normally produce explosive gases. Do not allow naked flames, sparks or lighted substances to come
near the battery.

When charging the battery shield your face and wear safety goggles. Provide adequate ventilation.

CAUTION:

Boost charging with excessive current or voltage above 16 volts will damage the battery.
Published: 11-May-2011

2012.0 XF (X250), 100-00

General Information

Brake System Health and Safety Precautions (G565862)


DESCRIPTION AND OPERATION
WARNINGS:

EYE CONTACT: Brake fluid contains polyglycol ethers and polyglycols. Avoid contact with the eyes. Wash
hands thoroughly after handling. If brake fluid comes into contact with the eyes, flush the eyes with plenty of
cold running water for 15 minutes. Seek medical attention for any persistent eye irritation or abnormality.

SWALLOWED: Brake fluid contains polyglycol ethers and polyglycols. If swallowed, drink plenty of water.
Seek immediate medical attention.

INHALED: Dust from friction materials can be harmful if inhaled.

Only use new specified brake fluid from airtight containers.

CAUTION:

If brake fluid is spilled on the paintwork, the affected area must be immediately washed down with cold water.
Published: 11-Apr-2019

2012.0 XF (X250), 100-00

General Information

Diesel Fuel System Health and Safety Precautions (G548997)


DESCRIPTION AND OPERATION
WARNINGS:

Fuel may not give adequate warning before toxic or harmful effects arise.

Exposure to fuel can be harmful and can cause severe health damage or death.

Provide adequate ventilation when working on fuel systems.

Extreme care must be exercised when handling hot fluids. Always wash off spilled fluids from affected areas
of skin immediately.

Fuel must not be used as a cleaning agent.

Keep fuel containers tightly closed, out of direct sunlight and in a cool area. Keep away from heat sources,
ignition sources and oxidizing agents.

SKIN CONTACT: Fuel is mildly irritating to the skin and may cause dermatitis due to defatting effect.
Remove contaminated clothing. Wash affected areas of skin with soap and water. Seek medical attention for
any persistent skin irritation or abnormality. Wash contaminated clothing before reuse.

SKIN CONTACT: Excessive or prolonged skin contact with diesel fuel may cause serious skin disorders
including skin cancer.

EYE CONTACT: Fuel is mildly irritating to the eyes. Flush with plenty of running water, blinking as often as
possible. Do not force the eyelid open. Seek medical attention for any persistent eye irritation or abnormality.

SWALLOWED: Fuel is moderately toxic and tends to foam on vomiting. If drawn into the lungs,
inflammation may develop. Do not induce vomiting. If spontaneous vomiting occurs place the victim in a
forward position to reduce the risk of fuel being drawn into the lungs. Give nothing by mouth. If breathing but
unconscious, place in the recovery position. If breathing has stopped, apply artificial respiration. Seek
immediate medical attention.

INHALED: Fuel is toxic to the respiratory and other body systems. Exposure may result in various symptoms
including drowsiness, unconsciousness or severe health damage. Move a victim to fresh air. Keep a victim
warm and at rest. If unconscious, place in the recovery position. If not breathing, apply artificial respiration.
Give cardiac massage if necessary. Seek immediate medical attention.

CAUTIONS:

Fuel injection equipment is manufactured to very precise tolerances and fine clearances. It is essential that
absolute cleanliness is observed when working with these components.

Make sure that the workshop area in which the vehicle is being worked on is as clean and as dust free as
possible.

Make sure that non-plated tools are used.


Tools must be cleaned using a new brush and fresh suitable evaporative cleaning agent.

Make sure to use a steel topped workbench covered with clean, lint-free, non-flocking material.

Make sure that all parts removed from the vehicle are placed on the lint-free, non-flocking material.

Make sure that any protective clothing worn is clean and made from lint-free, non-flocking material.

Make sure to wear non-powdered latex type gloves.

Make sure to protect all electrical components and connectors with lint-free non-flocking material before
using the suitable evaporative cleaning agent.

NOTE:

Soot, discomfort and irritation usually give adequate warning of hazardous fume concentrations.

Note: Refer to this document before carrying out any work on the fuel system.
Published: 12-Dec-2017

2012.0 XF (X250), 100-00

General Information

Fluid Leaks (G2224785)


DESCRIPTION AND OPERATION
GENERAL PROCEDURE - FLUID LEAK DETECTION

Symptom Possible Causes Action


Fluid leak from the vehicle or a leak is Coolant leaks Follow the service
discovered during a routine service Engine oil leaks instruction below
Transmission oil leaks
Fuel leaks
Anti-lock brake system
fluid leaks
Power steering fluid
leaks
Climate control system
fluid leaks
Windshield washer
reservoir fluid leaks
Visibly damaged or
worn parts

SERVICE INSTRUCTION

NOTES:

Slight surface oil dampness without drops are acceptable and should not be repaired as a leak

Be aware that fluid leaks from above any component may cause oil to collect on the engine and transmission
undershield i.e. engine leaks, oil cooler pipe leaks, fuel leaks, coolant leaks

Fixing the incorrect leak does not satisfy the customer

1. Remove any undershield or engine covers to gain access to the suspected leak area (REFER to: Workshop
Manual Section 501-02)

1. Using a suitable degreaser, thoroughly degrease the suspected component all the way around as well as,
approximately, 25-50mm (1-2 inches) above the suspected leak

1. Using a suitable leak detector spray, thoroughly coat the suspected component as well as, approximately, 25-
50mm (1-2 inches) above the suspected leak

1. Install the transmission/engine undershield and engine covers if removed (REFER to: Workshop Manual
Section 501-02)

1. Complete a suitable road test and make sure that the engine gets to normal operating temperature

1. Remove any undershield or engine covers to gain access to the suspected leak area (REFER to: Workshop
Manual Section 501-02)
1. Inspect the suspected component for fluid leaks, the detector spray should leave a trace from the leak area

Engine oil leak example graphic. Oil is present between the engine and transmission mating faces, including
evidence of oil in the 3 breather holes

1. Report or repair the source of the fluid leak

1. If no leak is found, continue diagnosis until the exact source of the leak is found

1. Install the transmission/engine undershield and engine covers if removed (REFER to: Workshop Manual
Section 501-02)
Published: 28-Sep-2015

2012.0 XF (X250), 100-00

General Information

General Service Information (G538587)


DESCRIPTION AND OPERATION
Repairs and Replacements

When service parts are required, it is essential that only genuine Jaguar/Daimler replacements are used.

Attention is drawn to the following points concerning repairs and the installation of replacement parts and
accessories:

Safety features embodied in the vehicle may be impaired if other than genuine parts are installed. In certain
territories, legislation prohibits the installation of parts which are not produced to the vehicle manufacturer's
specification.
Torque wrench setting figures given in this manual must be strictly adhered to. Locking devices, where
specified, must be installed. If the efficiency of a locking device is impaired during removal it must be
renewed.
Owners purchasing accessories while travelling abroad should make sure that the accessory and its installed
location on the vehicle conform to mandatory requirements existing in their country of origin.
The vehicle warranty may be invalidated by the installation of other than genuine Jaguar/Daimler parts. All
Jaguar/Daimler replacements have the full backing of the factory warranty.
Jaguar/Daimler dealers are obliged to supply only genuine service parts.

Vehicle Specifications

Purchasers are advised that the specification details set out in this manual apply to a range of vehicles and not to any
specific one. For the specification of a particular vehicle, purchasers should consult their dealer.

The Manufacturer reserves the right to vary the specifications, with or without notice, and at such times and in such
manner as the Manufacturer thinks fit. Major as well as minor changes may be involved, in accordance with the
Manufacturer's policy of continuous improvement.

Whilst every effort is made to make sure the accuracy of the particulars contained in this manual, neither the
Manufacturer nor the Dealer, by whom the manual is supplied, shall in any circumstances be held liable for any
inaccuracy or the consequences thereof.

Service Repair Operation Numbering

A master index of numbered operations has been compiled for universal application to all vehicles manufactured by
Jaguar Land Rover Limited.

Each operation is allocated a number from the master index and cross-refers with an identical number in the Repair
Operation Times schedule. The number consists of six digits arranged in three pairs.

Each maintenance procedure in this manual is described in the sequence necessary to complete the operation in the
minimum time, as specified in the Repair Operation Times schedule.

References to Bank-1 and Bank-2

References to Bank-1 and Bank-2 are made with regard to the engine. When viewed from the flywheel the right-
hand bank will be Bank-1 and the left-hand bank will be Bank-2.
Special Tools

Any special tools and equipment required to perform a maintenance procedure, are shown at the beginning of each
procedure. When possible, illustrations are given to assist in identifying the tool needed.

Disconnecting/Connecting the Battery

Always stop the engine before disconnecting the battery negative lead and make sure the battery positive lead is
isolated i.e. wrapped in a suitable cloth.

WARNING:

Radio code saving devices must not be used when conducting work on Air Bag or Fuel systems. It must be noted
that, when using these devices, the vehicle electrical system is still live albeit with a reduced current flow.

NOTE:

Before disconnecting the battery make sure that the radio receiver/cassette player/mini disc player and compact disc
player keycodes are known and, that no data is required from the Engine Control Module (ECM) as battery
disconnection will erase any fault codes and idle/drive values held in the Keep Alive Memory (KAM).

Always disconnect the battery before commencing repair operations which require:

The vehicle to be jacked up


Work on the engine
Work underneath the vehicle
Arc welding

Alternatively a Radio Code Saver may be used, when not working on the Air Bag or Fuel systems. With the battery
disconnected, a Radio Code Saver will allow sufficient current to pass to maintain the radio receiver/cassette
player/mini disc player and compact disc player memory, operate the clock and supply the door operated interior
lights while isolating the battery in the event of a short circuit.

Reconnecting the Battery


WARNING:

If the battery has been on bench charge the cells may be giving off explosive hydrogen gas. Avoid creating sparks,
and if in doubt cover the vent plugs or covers with a damp cloth.

Always make sure that all electrical systems are switched OFF before reconnecting the battery to avoid causing
sparks or damage to sensitive electrical equipment.

Always reconnect the battery positive lead first and the negative last, ensuring that there is a good electrical contact
and the battery terminals are secure.

Restart the clock (where installed) and set it to the correct time.

Enter the radio receiver/cassette player/mini disc player and compact disc player keycodes and preset' frequencies, if
known.

Following reconnection of the battery, the engine should be allowed to idle until it has reached normal operating
temperature as the stored idle and drive values contained within the ECM have been lost. Allow the vehicle to idle
for a further three minutes. Drive the vehicle at constant speeds of approximately 48 km/h (30 mph), 64 km/h (40
mph), 80 km/h (50 mph), 96 km/h (60 mph) and 112 km/h (70 mph) for three minutes each. This will allow the
ECM to relearn idle and drive values, and may cause driveability concerns if the procedure is not carried out.

Connecting a Slave Battery Using Jump Leads


WARNING:
If the slave battery has recently been charged and is gassing, cover the vent plugs or covers with a damp cloth to
reduce the risk of explosion should arcing occur when connecting the jump leads.

CAUTIONS:

A discharged battery condition may have been caused by an electrical short circuit. If this condition exists
there will be an apparently live circuit on the vehicle even when all circuits are switched off. This can cause
arcing when the jump leads are connected.

Whilst it is not recommended that the vehicle is jump started, it is recognized that this may occasionally be the
only practical way to mobilize a vehicle. In such an instance the discharged battery must be recharged
immediately after jump starting to avoid permanent damage.

Always make sure that the jump leads are adequate for the task. Heavy duty cables must be used.
Always make sure that the slave battery is of the same voltage as the vehicle battery. The batteries must be
connected in parallel.
Always make sure that switchable electric circuits are switched off before connecting jump leads. This reduces
the risk of sparks occurring when the final connection is made.

WARNING:

Make sure that the ends of the jump leads do not touch each other or ground against the vehicle body at any time
while the leads are attached to the battery. A fully charged battery, if shorted through jump leads, can discharge at a
rate well above 1000 amps causing violent arcing and very rapid heating of the jump leads and terminals, and can
even cause the battery to explode.

Always connect the jump leads in the following sequence.

Slave battery positive first then vehicle battery positive.


Slave battery negative next and then vehicle ground at least, 300 mm (12 in) from the battery terminal e.g.
engine lifting bracket.

Always reduce the engine speed to idle before disconnecting the jump leads.

Before removing the jump leads, switch on the heater blower (high) or the heated rear screen, to reduce the voltage
peak when the leads are removed.

Always disconnect the jump leads in the reverse order to the connecting sequence and take great care not to short the
ends of the leads.

Do not rely on the generator to restore a discharged battery. For a generator to recharge a battery, it would take in
excess of 8 hours continuous driving with no additional loads placed on the battery.

Component Cleaning

To prevent ingress of dirt, accumulations of loose dirt and greasy deposits should be removed before disconnecting
or dismantling components or assemblies.
Components should be thoroughly cleaned before inspection prior to reassembly.

Cleaning Methods:

Dry Cleaning
Removal of loose dirt with soft or wire brushes
Scraping dirt off with a piece of metal or wood
Wiping off with a rag

CAUTION:

Compressed air is sometimes wet so use with caution, especially on hydraulic systems.

Blowing dirt off with compressed air (Eye protection should be worn when using this method)
Removal of dry dust using vacuum equipment. This method should always be used to remove friction lining
material dust (asbestos particles)
Steam Cleaning

Calibration of Essential Measuring Equipment


WARNING:

Failure to comply may result in personal injury or damage to components.

It is of fundamental importance that certain essential equipment e.g. torque wrenches, multimeters, exhaust gas
analysers, rolling roads etc., are regularly calibrated in accordance with the manufacturers instructions.

Use of Control Modules

Control modules may only be used on the vehicle to which they were originally installed. Do not attempt to use or
test a control module on any other vehicle.

Functional Test

On completion of a maintenance procedure, a thorough test should be carried out, to ensure the relevant vehicle
systems are working correctly.

Preparation

Before disassembly, clean the surrounding area as thoroughly as possible. When components have been removed,
blank off any exposed openings using grease-proof paper and masking tape. Immediately seal fuel, oil and hydraulic
lines when separated, using plastic caps or plugs, to prevent loss of fluid and the entry of dirt. Close the open ends of
oil ways, exposed by component removal, with tapered hardwood plugs or readily visible plastic plugs. Immediately
a component is removed, place it in a suitable container; use a separate container for each component and its
associated parts. Before dismantling a component, clean it thoroughly with a recommended cleaning agent; check
that the agent will not damage any of the materials within the component. Clean the bench and obtain marking
materials, labels, containers and locking wire before dismantling a component.

Dismantling

Observe scrupulous cleanliness when dismantling components, particularly when parts of the brake, fuel or
hydraulic systems are being worked on. A particle of dirt or a fragment of cloth could cause a dangerous malfunction
if trapped in these systems. Clean all tapped holes, crevices, oil ways and fluid passages with compressed air.

WARNING:

Do not permit compressed air to enter an open wound. Always use eye protection when using compressed air.

Make sure that any O-rings used for sealing are correctly reinstalled or renewed if disturbed. Mark mating parts to
make sure that they are replaced as dismantled. Whenever possible use marking materials which avoid the
possibilities of causing distortion or the initiation of cracks, which could occur if a center punch or scriber were
used. Wire together mating parts where necessary to prevent accidental interchange (e.g roller bearing components).
Tie labels on to all parts to be renewed and to parts requiring further inspection before being passed for reassembly.
Place labelled parts and other parts for rebuild in separate containers. Do not discard a part which is due for renewal
until it has been compared with the new part, to make sure that the correct part has been obtained.

Inspection

Before inspecting a component for wear or performing a dimensional check, make sure that it is absolutely clean; a
slight smear of grease can conceal an incipient failure. When a component is to be checked dimensionally against
figures quoted for it, use the correct equipment (surface plates, micrometers, dial gauges etc.) in serviceable
condition. The use of makeshift equipment can be dangerous. Reject a component if its dimensions are outside the
limits quoted, or if damage is apparent. A component may be reinstalled if its critical dimension is exactly to the
limit size and it is otherwise satisfactory. Use Plastigauge 12 Type PG-1 for checking bearing surface clearance, e.g.
big end bearing shell to crank journal. Instructions for the use of Plastigauge and a scale giving bearing clearances in
steps of 0,0025 mm (0.0001 in) are supplied with the package.

On-Board Diagnostics (OBD)

This vehicle uses programmed electronic control systems to provide engine management and emission regulation,
automatic transmission operation and anti-lock braking control. These control systems are integral with the On-
Board Diagnostics (OBD) facility that is used in conjunction with either the Jaguar approved diagnostic system or
the more restricted scan tools.

The OBD information in this manual provides diagnostic and rectification procedures for emission related electrical
and mechanical systems. The information is intended to facilitate fault diagnosis and the subsequent rectification of
the vehicle without recourse to the Jaguar approved diagnostic system.

The diagnosis and testing sections within the manual cover:

System principles of operation with links to the relevant Description and Operation sections
Self tests (where appropriate)
Inspection and Verification - manual checks, symptom and Diagnostic Trouble Code (DTC) driven diagnostic
charts with actions required to rectify concerns
Component tests (where appropriate)

Circuit Diagrams

To understand the relationship between the vehicle electrical system and the system circuit diagrams, Refer to the
Electrical Guide.

In the interest of clarity, single lines may represent multiple wires. Refer to the color code (1st alpha) followed by
the wire reference (numeric/alpha/numeric) to trace origin and destination.

e.g. BW 647B002. BW (black with white trace) 647 (wire reference) B002 (stage from origin).

Glossary of Terms

This glossary of terms is intended to cover mainly emissions-related (to SAE J 1930) terminology, and other
abbreviations that may be used in this manual.

The required term may be looked-up in the left-hand column, and subsequent columns give the standard acronym,
unit or abbreviation, and definition.

Term(s) Acronym/Unit/Abbreviation Definition


Air Conditioning A/C
Accelerator Pedal APP Is a multitrack sensor which inputs the drivers demand into
Position the engine control module (ECM)
After Bottom Dead ABDC Event occurring after bottom dead center
Center
After Top Dead Center ATDC Event occurring after top dead center
Anti-lock Brake ABS System which prevents wheel lock-up under braking by
System sensing lack of rotation of a wheel(s) and diverting fluid
pressure away from it (them)
Alternating Current ac
Amplitude Modulation AM
Automatic ATC
Temperature Control
Automatic ATF
Transmission Fluid
Ampere A SI unit of current
Ampere hour Ah
Barometric Pressure BARO Pressure of surrounding air at any given temperature and
altitude
Battery positive B+ The positive voltage from a battery or any circuit
voltage connected directly to it
Before Bottom Dead BBDC Event occurring before bottom dead center
Center
Before Top Dead BTDC Event occurring before top dead center
Center
Bottom Dead Center BDC Lowest point of piston travel in a reciprocating engine
Battery Junction Box BJB
Brake Pedal Position BPP
Brake Horsepower BHP Effective horsepower developed by an engine or motor, as
measured by a brake applied to its output shaft
British Standard BS Standard specification issued by the British Standards
Institution
Brake Traction Control BTCS
System
Bus Topology of a
communication network
Coast Clutch Solenoid CCS
Camshaft Position CMP Indicates camshaft position
Carbon dioxide CO² Colorless gas with a density of approximately 1.5 times
that of air
Carbon monoxide CO Poisonous gas produced as the result of incomplete
combustion
Chlorofluorocarbon CFC
Catalytic converter In-line exhaust system device used to reduce the level of
engine exhaust emissions
Celsius C SI term for the Centigrade scale, with freezing point at zero
and boiling point at 100 degrees
Compact Disc CD
Cylinder Head CHT Sensor A sensor for measuring the temperature of the cylinder
Temperature Sensor head
Central Junction Box CJB
Crankshaft Position CKP Indicates crankshaft position
Clutch Pedal Position CPP Indicates clutch pedal position
Controller Area CAN A communication system which allows control modules to
Network be linked together
Constant Velocity CV
Cubic centimeter cm³
Central Security CSM Electronic module to support security system functionality
Module
Data Link Connector DLC Connector providing access and/or control of the vehicle
information, operating conditions, and diagnostic
information
Driver Door Module DDM Electronic module to support driver door functionality
Driver Seat Module DSM Electronic module to support driver seat functionality
Daytime Running DRL
Lamps
Deutsche Institut fur DIN German standards regulation body
Normung
Diagnostic Trouble DTC An alpha/numeric identifier for a fault condition identified
Code by the On-Board Diagnostic (OBD) system
Direct current dc Current which flows in one direction only, though it may
have appreciable pulsations in its magnitude
Domestic Data Bus D2B
Digital Versatile Disc DVD
Electronic Automatic EATC
Temperature Control
Exhaust Gas EGR
Recirculation
Exhaust Gas EGRT Sensing EGR function based on temperature change
Recirculation
Temperature Sensor
Electronic Brake Force EBD
Distribution
Engine Control Module ECM Electronic module to support engine functionality
Electronic Crash ECS Sensor to measure severity of impact
Sensor
Engine Coolant ECT
Temperature
Engine Oil Pressure EOP
European On-Board EOBD
Diagnostic
Electronic Pressure EPC
Control
Electrically Erasable EEPROM
Programmable Read-
Only Memory
Erasable EPROM
Programmable Read-
Only Memory
Evaporative Emission EVAP System designed to prevent fuel vapor from escaping into
the atmosphere. Typically includes a charcoal filled
canister to absorb fuel vapor
Flash Electrically FEEPROM
Erasable
Programmable Read-
Only Memory
Front Electronic FEM
Module
Flash Erasable FEPROM
Programmable Read-
Only Memory
Frequency Modulation FM
Fuel Pump Driver FPDM
Module
Fuel Rail Pressure FRP
Generic Electronic GEM
Module
Ground GND Electrical conductor used as a common return for an
electrical circuit or circuits, and with a relative zero
potential
Global Positioning GPS
System
Global System for GSM
Mobile
Communication
Gross Vehicle Weight GVW
Heated Oxygen Sensor HO2S Electrically heated oxygen sensor which induces fuelling
corrections
Hydrofluorocarbon HFC
High tension HT
Hydrocarbon HC
Idle Air Control IAC Stepper motor driven device which varies the volume of air
by-passing the throttle to maintain the programmed idle
speed
Intake Air Temperature IAT Temperature of intake air
Inertia Fuel Shut-off IFS An inertia system that shuts off the fuel supply when
activated by pre-determined force limits brought about by
(e.g.) collision
Input Shaft Speed ISS Indicates input shaft speed
Key On, Engine Off KOEO
Key On, Engine KOER
Running
Kilogram (mass) kg
Kilogram (force) kgf
Kilogram force per kgf/cm²
square centimeter
Kilometer km
Kilometer per hour km/h
Kilopascal kPa
Kilovolt kV
Knock Sensor KS Sensor which detects the onset of detonation, and signals
the ECM to retard the ignition
Liquid Crystal Display LCD Optical digital display system, to which applied voltage
varies the way the crystals reflect light, thereby modifying
the display
Lighting Control LCM
Module
Light Emitting Diode LED
Low Tension LT Primary circuit of the ignition system, linking the battery to
the primary winding in the ignition coil
Left-Hand LH
Left-Hand Drive LHD
Mass Air Flow MAF System which provides information on the mass flow rate
of the intake air to the engine
Manifold Absolute MAP Absolute pressure of the intake manifold air
Pressure
Manifold Absolute MAPT
Pressure and
Temperature
Malfunction Indicator MIL A required on-board indicator to alert the driver of an
Lamp emission related malfunction
Meter (measurement) m
Metric (screw thread, M
e.g. M8)
Farad F Unit of electrical capacitance
Millimeter mm
Millimeter of mercury mmHg
Millisecond ms
Model year MY
Newton N SI unit of force. 1 N = 0.2248 pounds force
Newton Meter Nm SI unit of torque. Must not be confused with nm
(nanometer)
Negative Temperature NTC
Coefficient
Naturally aspirated N/A Fuelling system using intake air at atmospheric pressure;
not supercharged or turbocharged
Noise, Vibration and NVH
Harshness
North American NAS Vehicles for sale in the USA and Canadian markets
Specification
On-Board Diagnostic OBD A system that monitors some or all computer input and
output control signals. Signal(s) outside the pre-determined
limits imply a fault in the system or a related system
Oxides of Nitrogen Nox
Oxygen Sensor O2S A sensor which detects oxygen content in the exhaust gases
On-board Refuelling ORVR
Vapour Recovery
Output State Control OSC
Output Shaft Speed OSS
Passenger Air Bag PAD
Deactivation
Pulsed Secondary Air PAIR
Injection
Passive Anti-Theft PATS
System
Positive Crankcase PCV
Ventilation
Parameter PID An index number referring to a parameter within a module
Identification without knowledge of its storage location
Park/Neutral Position PNP
Pulse Width PWM
Modulation
Programmable PECUS Process whereby a common ECM is programmed on the
Electronic Control production line to suit the market requirements of a
Units System particular vehicle
Programmable Read- PROM ROM with some provision for setting the stored data after
only Memory manufacture
Portable Support PSE
Electronics
Power Steering PSP
Pressure
Polytetrafluoroethylene PTFE
Random Access RAM Fast access memory store which is accessible for entry or
Memory extraction of data
Read Only Memory ROM Fast access memory in which data is fixed and may not be
changed
Restraints Control RCM Electronic module to support functionality of the
Module Supplemental Restraints System
Radio Data System RDS
Rear Electronic REM
Module
Remote Keyless Entry RKE
Right-hand RH
Right-hand drive RHD
Research Octane RON
Number
Rear Seat Module RSM Electronic module to support functionality of rear seats
Supercharger SC An intake system which utilizes a supercharger
(mechanically driven device that pressurizes intake air,
thereby increasing density of charge air and the consequent
power output from a given displacement)
Serial Communications SCL
Link
Standard Corporate SCP A high-speed, serial communications system linking all
Protocol body system control modules. Control messages and data
are passed between modules at up to 786 messages per
second
Supplemental SRS
Restraints System
Shift Solenoid SS Controls shifting in an automatic transmission
Seat Control Module SCM Module controlling the seat motor systems (not electric
raise/lower-only seats)
Secondary Air AIR System used for a period of time each time the engine is
Injection started, unless certain temperature criteria are met. Pumps
air directly into the exhaust system which generates extra
heat and reduces the time taken for the catalytic converters
to reach operating temperature
Service Repair SRO Number generated by Jaguar Methods & Techniques
Operation (number) system which relates to the time allowed to complete a
repair operation. Further information on the system can be
found in the separate Jaguar Publications (for each model
range) entitled 'Repair Operation Times'
Society of Automotive SAE
Engineers
Timing/Coast Clutch T/CCS
Solenoid
Torque Converter TCC
Clutch
Transmission Control TCIL
Indicator Lamp
Throttle Position TP
Top Dead Center TDC
Transmission Control TCM Controls the shifting pattern of the (automatic)
Module transmission
Transmission Control TCS Modifies the operation of electronically controlled
Switch transmissions
Transmission Fluid TFT Indicates temperature of transmission fluid
Temperature
Transmission Range TR The range in which the transmission is operating
Turbine Shaft Speed TSS Indicates rotational speed of transmission output shaft or
turbine shaft
Variable Assist Power VAPS
Steering
Variable Camshaft VCT A system by which the relationship of the crankshaft and
Timing camshaft may be altered during engine running
Vehicle Identification VIN Number assigned to the vehicle by the manufacturer,
Number primarily for licensing and identification purposes
Vehicle Speed Sensor VSS Sensor which provides vehicle speed information
Worldwide Diagnostic WDS Jaguar approved diagnostic system
System
Wide Open Throttle WOT Full throttle position
Published: 15-Feb-2020

2012.0 XF (X250), 100-00

General Information

Health and Safety Precautions (G544155)


DESCRIPTION AND OPERATION

The Health and Safety Precautions subsection refers to some commonly used chemicals and materials, hazards
associated with their use, and safety measures to be taken. Some of these chemicals may be included in the
following list either in their own right or as an ingredient in a sealer or adhesive.

Acids and Alkalis

See also Battery Acids.

e.g. caustic soda, sulphuric acid.

Used in batteries and cleaning materials.

Irritant and corrosive to the skin, eyes, nose and throat. Cause burns. Can destroy ordinary protective clothing.

Avoid splashes to the skin, eyes and clothing. Wear suitable protective impervious apron, gloves and goggles. Do
not breath mists.

Ensure access to eye wash bottles, shower and soap are readily available for splashing accidents.

Display Eye Hazard sign.

Air Bags

See also Fire, Chemical Materials - General

Highly flammable, explosive – observe No Smoking policy.

Used as a part of the Supplemental Restraint System (SRS), mounted in various positions around the vehicle.

The inflator contains a high-energetic propellant which, when ignited, produces a VERY HOT GAS (2500° C).

The gas generant used in air bags is Sodium Azide. This material is hermetically sealed in the module and is
completely consumed during deployment. No attempt should be made to open an air bag inflator as this will lead to
the risk of exposure to Sodium Azide. If a gas generator is ruptured, full protective clothing should be worn when
dealing with the spillage.

After normal deployment, gloves and safety goggles should be worn during the handling process.

Deployed air bags should be disposed of in a plastic bag in accordance with local regulations at an approved
chemical waste site.

Following any direct contact with gas generant.

Wash affected areas thoroughly with water


Seek medical assistance if necessary

WARNINGS:
Observe due care when working on or near hot components. This may include, but is not limited to:

Exhaust systems
Emissions control systems
Cooling systems
Climate control systems
Braking systems
Lubrication systems
Vehicle powertrain systems
Electric vehicle systems.

To avoid accidental deployment and possible personal injury, the backup power supply must be depleted
before repairing or replacing any SRS components. To deplete the backup power supply energy, disconnect
the battery negative cable and wait for one minute. Failure to follow this instruction may result in personal
injury.

NOTE:

The storage, transportation, disposal and/or recycling of air bag modules must be carried out in accordance with all
applicable federal, state and local regulations including, but not limited to, those governing building and fire codes,
environmental protection, occupational health and safety and transportation.

Air Bags - Do's

Do store in an air bag safe when not installed to the vehicle.


Do store modules in an upright position
Do keep modules dry
Do carry modules with the cover side pointing away from the body
Do place modules with their cover side upwards
Do carefully inspect modules for damage
Do stand to one side when connecting modules
Do make sure all test equipment is properly calibrated and maintained
Do wash you hands after handling deployed air bags
Do wear safety glasses when carrying out repairs to the SRS or when handling an air bag module
Only carry out a system test with the air bag modules fully installed
Do inspect the condition of the impact sensor mounting bracket and sensor flylead if the vehicle has been
involved in an impact. Replace if damaged, even if there has been no deployment.

Air Bags - Do Nots

Do not store highly flammable material together with modules or gas generators
Do not store gas generators at temperatures exceeding 80° C
Do not store modules upside down
Do not attempt to open a gas generator housing
Do not expose gas generators to open flame or sources of heat
Do not place anything on top of a module cover
Do not use damaged modules
Do not handle a deployed device or gas generator for at least 20 minutes
Do not probe air bag module electrical connectors or any other SRS component

Air Conditioning Refrigerant

See also Chlorofluorocarbon, Chemical Materials

Highly flammable, combustible – observe No Smoking policy.

Skin contact may result in frostbite.


Instructions given by the manufacturer must be followed. Avoid naked lights, wear suitable protective gloves and
goggles.

If refrigerant comes into contact with the skin or eyes, rinse the affected areas with water immediately. Eyes should
also be rinsed with an appropriate irrigation solution and should not be rubbed. SEEK MEDICAL ASSISTANCE IF
NECESSARY.

Air Conditioning Refrigerant - Do Nots

Do not expose refrigerant bottles to sunlight or heat


Do not expose refrigerant bottles to frost
Do not drop refrigerant bottles
Do not vent refrigerant to atmosphere under any circumstance
Do not mix refrigerants i.e. R12 (Freon) and R134a

Antifreeze

See also Fire, Solvents.

e.g. isopropanol, ethylene glycol, methanol.

Highly flammable, flammable, combustible.

Used in vehicle coolant systems, brake air pressure systems, screenwash solutions.

Vapors may be given off from coolant antifreeze (glycol) when heated. Avoid breathing these vapors.

Antifreeze may be absorbed through the skin in toxic or harmful quantities. Antifreeze, if swallowed can be fatal and
medical attention should be sought immediately.

These products must not be used in any cooling or industrial water system which is connected or linked to general,
food preparation or drinking water supplies.

Asbestos

Used in brake and clutch linings, transmission brake bands and gaskets. Jaguar original production and replacement
items are asbestos free.

See also Warning Symbols on Vehicles at the end of this subsection.

Breathing asbestos dust may cause lung damage or, in some cases, cancer.

The use of drum cleaning units, vacuum cleaning or damp wiping is preferred.

Asbestos dust waste should be dampened, placed in a sealed container and marked to make sure safe disposal. If any
cutting or drilling is attempted on materials containing asbestos the item should be dampened and only hand tools or
low speed power tools used.

Battery Acids

See also Acids and Alkalis.

Gases released during charging are explosive. Never use naked flames or allow sparks near charging or recently
charged batteries.

Ensure adequate ventilation.

Brake and Clutch Linings and Pads

See Asbestos.
Brake Fluids (Polyalkylene Glycols)

See also Fire.

Splashes to the skin and eyes may cause irritation. Avoid skin and eye contact as far as possible. Vapor inhalation
hazards do not arise at ambient temperatures because of the very low vapor pressure.

Brazing

See Welding.

Chemical Materials

See also Legal Aspects.

Chemical materials such as solvents, sealers, adhesives, paints, resin foams, battery acids, antifreeze, brake fluids,
fuels, oils and grease should always be used with caution and stored and handled with care. They may be toxic,
harmful, corrosive, irritant or highly flammable and give rise to hazardous fumes and dusts.

The effects of excessive exposure to chemicals may be immediate or delayed; briefly experienced or permanent;
cumulative; superficial; life threatening; or may reduce life-expectancy.

Chemical Materials - Do's

Do carefully read and observe hazard and precaution warnings given on material containers (labels) and in any
accompanying leaflets, posters or other instructions. Material health and safety data sheets can be obtained
from manufacturers
Do remove chemical materials from the skin and clothing as soon as practical after soiling. Change heavily
soiled clothing and have it cleaned
Do organise work practices and protective clothing to avoid soiling of the skin and eyes, and the breathing in
of vapors, aerosols, dusts or fumes
Do wash before breaks, before eating, smoking, drinking or using toilet facilities when handling chemical
materials
Do keep work areas clean, uncluttered and free from spills
Do store chemical materials according to national and local regulations
Do keep chemical materials out of the reach of children

Chemical Materials - Do Nots

Do not mix chemical materials except under the manufacturer's instructions; some chemicals can form other
toxic or harmful chemicals, give off toxic or harmful fumes or become explosive when mixed together
Do not spray chemical materials, particularly those based on solvents, in confined spaces e.g. when people are
inside a vehicle
Do not apply heat or flame to chemical materials except under the manufacturer's instructions. Some are
highly flammable and some may release toxic or harmful fumes
Do not leave containers open. Fumes given off can build up to toxic, harmful or explosive concentrations.
Some fumes are heavier than air and will accumulate in confined areas, pits etc.
Do not transfer chemical materials to unlabeled containers
Do not clean hands or clothing with chemicals. Chemicals, particularly solvents and fuels, will dry skin and
may cause irritation leading to dermatitis or be absorbed through the skin in toxic or harmful quantities
Do not use emptied containers for other materials except when they have been cleaned under supervised
conditions
Do not sniff or smell chemical materials. Brief exposure to high concentrations of fumes can be toxic or
harmful

Chlorofluorocarbons (CFC)

There is concern in the scientific community that CFCs and Halons are depleting the upper ozone layer which filters
out harmful ultraviolet radiation. Decreased filtration of ultraviolet radiation may result in increases in skin cancer,
cataracts and immune system suppression in humans, as well as decreased productivity of crops and aquatic systems.

CFCs are used primarily as refrigerants in vehicle air conditioning systems and as aerosol propellants. Halons are
used as fire extinguishants.

Jaguar supports worldwide elimination of CFC usage and it is recommended that Company subsidiaries and
affiliates should phase out CFC usage as soon as acceptable substitutes are commercially available.

Clutch Fluids

See Brake fluids.

Clutch Linings and Pads

See Asbestos.

Corrosion Protection Materials

See also Solvents, Fire.

Highly flammable, flammable – observe No Smoking policy.

These materials are varied and the manufacturer's instructions should be followed. They may contain solvents,
resins, petroleum products etc. Skin and eye contact should be avoided. They should only be sprayed in conditions
of adequate ventilation and not in confined spaces.

Cutting

See Welding.

Dewaxing

See Solvents and Fuels (Kerosene).

Dusts

Powder, dusts or clouds may be irritant, harmful or toxic. Avoid breathing dusts from powdery chemical materials or
those arising from dry abrasion operations. Wear respiratory protection if ventilation is inadequate.

Fine dusts of combustible material can present an explosion hazard. Avoid explosive limits and/or sources of
ignition.

Electric Shock

Electric shock can result from the use of faulty electrical equipment or from the misuse of equipment in good
condition.

Ensure that electrical equipment is maintained in good condition and frequently tested. Faulty equipment should be
labelled and preferably removed from the work station.

Ensure that flexes, cables, plugs and sockets are not frayed, kinked, cut, cracked or otherwise damaged.

Ensure that electrical equipment and flexes do not come into contact with water.

Ensure that electrical equipment is protected by the correct rated fuse.

Never misuse electrical equipment and never use equipment which is in any way faulty. The results could be fatal.

Ensure that the cables of mobile electrical equipment cannot get trapped and damaged, such as in a vehicle hoist.
Ensure that the designated electrical workers are trained in basic First Aid.

In cases of electrocution:

Switch off the power supply before approaching the victim


If this is not possible push or drag the victim from the source of electricity using dry non-conductive material
Commence resuscitation if trained to do so
SUMMON MEDICAL ASSISTANCE

Engine Oils

See Lubricants and Grease.

Exhaust Fumes

These contain asphyxiating, harmful and toxic chemicals and particles such as carbon oxides, nitrogen oxides,
aldehydes, lead and aromatic hydrocarbons. Engines should be run only under conditions of adequate exhaust
extraction or general ventilation and not in confined spaces.

Gasolene (petrol) engine

There may not be adequate warning of odour or of irritation before toxic or harmful effects arise. These may be
immediate or delayed.

Fibre Insulation

See also Dusts.

Used in noise and sound insulation.

The fibrous nature of surfaces and cut edges can cause skin irritation. This is usually a physical and not a chemical
effect.

Precautions should be taken to avoid excessive skin contact through careful organization of work practices and the
use of gloves.

Fire

See also Welding, Foams, Legal Aspects.

Many of the materials found on or associated with the repair of vehicles are highly flammable. Some give off toxic
or harmful fumes if burnt.

Observe strict fire safety when storing and handling flammable materials or solvents, particularly near electrical
equipment or welding processes.

Ensure, before using electrical or welding equipment, that there is no fire hazard present.

Have a suitable fire extinguisher available when using welding or heating equipment.

First Aid

Apart from meeting any legal requirements it is desirable for someone in the workshop to be trained in First Aid
procedures.

Splashes in the eye should be flushed carefully with clean water for at least ten minutes.

Soiled skin should be washed with soap and water.

Individuals affected by inhalation of gases, fumes etc. should be removed to fresh air immediately. If effects persist,
consult a doctor.

If liquids are swallowed inadvertently, consult a doctor giving the information on the container or label. Do not
induce vomiting unless this action is indicated on the label.

Fluoroelastomer

See Viton.

Foams - Polyurethane

See also Fire.

Used in sound and noise insulation. Cured foams used in seat and trim cushioning.

Follow manufacturer's instructions.

Unreacted components are irritating and may be harmful to the skin and eyes. Wear gloves and goggles.

Individuals with chronic respiratory diseases, asthma, bronchial medical problems, or histories of allergic diseases
should not work in or near uncured materials.

The components, vapors or spray mists can cause direct irritation, sensitivity reactions and may be toxic or harmful.

Vapors and spray mists must not be inhaled. These materials must be applied with adequate ventilation and
respiratory protection. Do not remove the respirator immediately after spraying, wait until the vapor/mists have
cleared.

Burning of the uncured components and the cured foams can generate toxic and harmful fumes. Smoking, naked
flames or the use of electrical equipment during foaming operations and until vapors/mists have cleared should not
be allowed. Any heat cutting of cured foams or partially cured foams should be conducted with extraction
ventilation.

Freon

See Air Conditioning Refrigerant.

Fuels

See also, Fire, Legal Aspects, Chemicals and Solvents.

Avoid skin contact with fuel where possible. Should contact occur, wash the affected skin with soap and water.

Gasoline (Petrol)

Highly flammable - observe No Smoking policy.

Swallowing can result in mouth and throat irritation and absorption from the stomach can result in drowsiness and
unconsciousness. Small amounts can be fatal to children. Aspiration of liquid into the lungs e.g. through vomiting, is
a very serious hazard.

Gasoline dries the skin and can cause irritation and dermatitis on prolonged or repeated contact. Liquid in the eye
causes severe pain.

Motor gasoline may contain appreciable quantities of benzene, which is toxic upon inhalation, and the concentration
of gasoline vapors must be kept very low. High concentrations will cause eye, nose and throat irritation, nausea,
headache, depression and symptoms of drunkenness. Very high concentrations will result in rapid loss of
consciousness.

Ensure there is adequate ventilation when handling and using gasoline. Great care must be taken to avoid the serious
consequences of inhalation in the event of vapor build up arising from spillages in confined spaces.

Special precautions apply to cleaning and maintenance operations on gasoline storage tanks.

Gasoline should not be used as a cleaning agent. It must not be siphoned by mouth. See First Aid.

Gas - oil (Diesel Fuel)

See warnings and cautions in relevant manual sections.

Combustible.

Gross or prolonged skin contact with high boiling point gas oils may also cause serious skin disorders including skin
cancer.

Kerosene (Paraffin)

Used also as heating fuel, solvent and cleaning agent.

Flammable - observe No Smoking policy.

Irritation of the mouth and throat may result from swallowing. The main hazard from swallowing arises if liquid
aspiration into the lungs occurs.

Liquid contact dries the skin and can cause irritation or dermatitis. Splashes in the eye may be slightly irritating.

In normal circumstances the low volatility does not give rise to harmful vapors. Exposure to mists and vapors from
kerosene at elevated temperature should be avoided (mists may arise in dewaxing). Avoid skin and eye contact and
make sure there is adequate ventilation.

Gas Cylinders

See also Fire.

Gases such as oxygen, acetylene, argon and propane are normally stored in cylinders at pressures of up to 13.790
kPa, (2000 lb/in²) and great care should be taken in handling these cylinders to avoid mechanical damage to them or
to the valve gear attached. The contents of each cylinder should be clearly identified by appropriate markings.

Cylinders should be stored in well ventilated enclosures, and protected from ice and snow, or direct sunlight. Fuel
gases (e.g. acetylene and propane) should not be stored in close proximity to oxygen cylinders.

Care should be exercised to prevent leaks from gas cylinders and lines, and to avoid sources of ignition.

Only trained personnel should undertake work involving gas cylinders.

Gases

See Gas Cylinders.

Gaskets (Fluoroelastomer)

See Viton.

General Workshop Tools and Equipment

It is essential that all tools and equipment are maintained in good condition and the correct safety equipment is used
where required.

Never use tools or equipment for any purpose other than that for which they were designed. Never over – load
equipment such as hoists, jacks, axle and chassis stands or lifting slings. Damage caused by overloading is not
always immediately apparent and may result in a fatal failure the next time that the equipment is used.

Do not use damaged or defective tools or equipment, particularly high speed equipment such as grinding wheels. A
damaged grinding wheel can disintegrate without warning and cause serious injury.

Wear suitable eye protection when using grinding, chiselling or sand blasting equipment.

Wear a suitable breathing mask when using abrasive blasting equipment, working with asbestos-based materials or
using spraying equipment.

Ensure adequate ventilation to control dusts, mists and fumes.

High Pressure Air, Lubrication and Oil Test Equipment

See also Lubricants and Greases.

Always keep high pressure equipment in good condition, and regularly maintained, particularly at joints and unions.

Never direct a high pressure nozzle, e.g. diesel injector, at the skin as the fluid may penetrate to the under - lying
tissue etc., and cause serious injury.

Halon

See CFCs.

Legal Aspects

Many laws and regulations make requirements relating to health and safety in the use and disposal of materials and
equipment in workshops. Some of these laws which apply in the UK are listed. Similar laws exist for other
territories:

The Factories Act (1961)


The Asbestos Regulations (1969)
Highly Flammable Liquids and Liquified Petroleum Gases Regulations (1972)
Control of Pollution Act (1974)
Health and Safety at Work Act (1974)
The Classification, Packaging and Labelling of Dangerous Substances Regulations (1978, 1981, 1983, 1984)
Control of Lead at Work Regulations (1980)
Control of Substances Hazardous to Health (COSHH) Regulations (1989)
Abrasive Wheels Regulations (1970)
Reporting of injuries, diseases and dangerous occurrences regulations 1985 (RIDDOR)

Workshops should be familiar, in detail, with these and associated laws and regulations.

Consult the local factory inspectorate if in any doubt.

Lubricants and Greases

Avoid all prolonged and repeated contact with mineral oils. All lubricants and greases may be irritating to the eyes
and skin.

Used Engine Oil

Prolonged and repeated contact with mineral oil will result in the removal of natural oils from the skin, leading to
dryness, irritation and dermatitis. In addition, used engine oil contains potentially harmful contaminants which may
cause skin cancer. Adequate means of skin protection and washing facilities must be provided.

Do not employ used engine oils as lubricants or for any application where appreciable skin contact is likely to occur.

There are publications describing the problems and advising on precautionary measures. For the UK a typical Health
and Safety Executive publication is: SHW 397: Cautionary Notice: Effects of mineral oil on the skin.

Health Protection Precautions

Avoid prolonged and repeated contact with oils, particularly used engine oils
Wear protective clothing, including impervious gloves where practicable
Do not put oily rags into pockets
Avoid contaminating clothing with oil
Heavily soiled clothing and oil-impregnated footwear should not be worn. Overalls must be cleaned regularly
First Aid treatment should be obtained immediately for open cuts and wounds.
Use barrier creams, applying them before each work period, to enable easier removal of dirty oil and grease
from the skin
Wash with soap and water to make sure all oil is removed (skin cleansers and nail brushes will help).
Preparations containing lanolin replace the natural skin oils which have been removed
Do not use gasoline (petrol), kerosene (paraffin), diesel fuel (gas oil), thinners or solvents for cleaning skin.
If skin disorders develop, obtain medical advice without delay
Where practical, degrease components prior to handling
Where there is a risk of eye contact, eye protection should be worn, for example, goggles or face shields; in
addition an eye wash facility should be provided

Environmental Precautions

Burning used engine oil in small space heaters or boilers can be recommended only for units of approved design. In
the UK the heating system must meet the requirements of HM Inspectorate of Pollution for small burners of less
than 0.4 MW. If in doubt check with the appropriate local authority and/or manufacturer of approved appliances.

Dispose of used oil and used oil filters through authorized waste disposal contractors or licensed waste disposal
sites, or to the waste oil reclamation trade, batteries should also be disposed off under similar arrangements. If in
doubt, contact the relevant local authority for advice on disposal facilities.

It is illegal to pour used oil, antifreeze and automatic transmission fluid on to the ground, down sewers, drains, or
into water courses.

Noise

Some operations may produce high noise levels which could, in time, damage hearing. In these cases, suitable ear
protection must be worn.

Noise Insulation Materials

See Foams, Fibre Insulation.

0-Rings (Fluoroelastomer)

See Viton.

Paints

See also body and paint manual.

See also Solvents, Chemical Materials.

Highly flammable, flammable - observe No Smoking policy

Pressurized Equipment

See High Pressure Air, Lubrication and Oil Test Equipment.

Solder
Solders are a mixture of metals such that the melting point of the mixture is below that of the constituent metals
(normally lead and tin). Solder application does not normally give rise to toxic lead fumes, provided a gas/air flame
is used. Oxy-acetylene flames should not be used, as they are much hotter and will cause lead fumes to be produced.

Some fumes may be produced by the application of any flame to surfaces coated with grease etc. and inhalation of
these should be avoided.

Removal of excess solder should be undertaken with care, to make sure that fine lead dust is not produced, which
can give toxic effects if inhaled. Respiratory protection may be necessary.

Solder spillage and filings should be collected and removed promptly to prevent general air contamination by lead.

High standards of personal hygiene are necessary in order to avoid ingestion of lead or inhalation of solder dust from
clothing.

Solvents

See also Chemical Materials, Fuels (Kerosene), Fire.

e.g. acetone, white spirit, toluene, xylene, trichloroethane.

Used in cleaning and de-waxing materials, paints, plastics, resins, thinners etc.

Some may be highly flammable or flammable.

Skin contact will degrease the skin and may result in irritation and dermatitis following repeated or prolonged
contact. Some can be absorbed through the skin in toxic or harmful quantities.

Splashes in the eye may cause severe irritation and could lead to loss of vision.

Brief exposure to high concentrations of vapors or mists will cause eye and throat irritation, drowsiness, dizziness,
headaches and, in the worst circumstances, unconsciousness.

Repeated or prolonged exposure to excessive but lower concentrations of vapors or mists, for which there might not
be adequate warning indications, can cause more serious toxic or harmful effects.

Aspiration into the lungs (e.g. through vomiting) is the most serious consequence of swallowing.

Avoid splashes to the skin, eyes and clothing. Wear protective gloves, goggles and clothing if necessary.

Ensure good ventilation when in use, avoid breathing fumes, vapors and spray mists and keep containers tightly
sealed. Do not use in confined spaces.

When spraying materials containing solvents, e.g. paints, adhesive, coatings, use extraction ventilation or personal
respiratory protection in the absence of adequate general ventilation.

Do not apply heat or flame except under specific and detailed manufacturer's instructions.

Sound Insulation

See Fibre Insulation, Foams.

Suspended Loads
CAUTION:

Never improvise lifting tackle.

There is always a danger when loads are lifted or suspended. Never work under an unsupported, suspended or raised
load e.g. suspended engine, etc.
Always make sure that lifting equipment such as jacks, hoists, axle stands, slings, etc., are adequate and suitable for
the job, in good condition and regularly maintained.

Transmission Brake Bands

See Asbestos.

Underseal

See Corrosion Protection.

Viton

In common with many other manufacturers' vehicles, some components installed to the Jaguar range have 'O' rings,
seals or gaskets which contain a material known as 'Viton'.

Viton is a fluoroelastomer, that is a synthetic rubber type which contains Fluorine. It is commonly used for 'O' rings,
gaskets and seals of all types. Although Viton is the most well known fluoroelastomer, there are others, including
Fluorel and Tecmoflon.

When used under design conditions fluoroelastomers are perfectly safe. If, however, they are exposed to
temperatures in excess of 400º C, the material will not burn, but will decompose, and one of the products formed is
hydrofluoric acid.

This acid is extremely corrosive and may be absorbed directly, through contact, into the body.

'O' rings, seals or gaskets which have been exposed to very high temperatures will appear charred or as a black
sticky substance.

DO NOT, under any circumstances touch them or the attached components.

Enquiries should be made to determine whether Viton or any other fluoroelastomer has been used in the affected 'O'
ring, seal or gasket. If they are of natural rubber or nitrile there is no hazard. If in doubt, be cautious and assume that
the material may be Viton or any fluoroelastomer.

If Viton or any other fluoroelastomers have been used, the affected area should be decontaminated before the
commencement of work.

Disposable heavy duty plastic gloves should be worn at all times, and the affected area washed down using wire
wool and a limewater (calcium hydroxide) solution to neutralize the acid before disposing of the decomposed Viton
residue and final cleaning of the area. After use, the plastic gloves should be discarded carefully and safely.

Welding

See also Fire, Electric Shock, Gas Cylinders.

Welding processes include Resistance Welding (Spot Welding), Arc Welding and Metal Active Gas (MAG)
Welding for Steel vehicles, Metal Inert Gas (MIG) for Aluminum vehicles.

Resistance Welding (Spot Welding)

This process may cause particles of molten metal to be emitted at a high velocity, and the eyes and skin must be
protected.

Arc Welding

This process emits a high level of ultraviolet radiation which may cause arc-eye and skin burns to the operator and to
other persons nearby. Gas-shielded welding processes are particularly hazardous in this respect. Personal protection
must be worn, and screens used to shield other people.
CONTACT LENS WEARERS ARE ADVISED TO REVERT TO ORDINARY SPECTACLES WHEN ARC
WELDING as the arc spectrum is believed to emit microwaves which dry out the fluid between the lens and the eye.
This may result in blindness when the lens is removed from the eye.

Metal spatter will also occur, and appropriate eye and skin protection is necessary.

The heat of the welding arc will produce fumes and gases from the metals being welded, the rods and from any
applied coatings or contamination on the surfaces being worked on. These gases and fumes may be toxic and
inhalation of these should be avoided. The use of extraction ventilation to remove the fumes from the working area
may be necessary particularly in cases where the general ventilation is poor, or where considerable welding work is
anticipated. In extreme cases or confined spaces where adequate ventilation cannot be provided, air-fed respirators
may be necessary.

SPECIAL PRECAUTIONS MUST BE TAKEN BEFORE ANY WELDING OR CUTTING TAKES PLACE ON
VESSELS WHICH HAVE CONTAINED COMBUSTIBLE MATERIALS, E.G. BOILING OR STEAMING OUT
OF FUEL TANKS.

Warning Symbols on Vehicles

Decals showing warning symbols will be found on various vehicle components.

These decals must not be removed. The warnings are for the attention of owners/operators and persons carrying out
service or repair operations on the vehicle.

The most commonly found decals are reproduced below together with an explanation of the warnings.

1. Components or assemblies displaying the warning triangle and open book symbol advise consultation of the
relevant section of the owners handbook before touching or attempting adjustments of any kind.

1. Components or assemblies displaying the warning triangle with the electrified arrow and open book symbol
give warning of inherent high voltages. Never touch these with the engine running or the ignition switched on.
See Electric Shock in this subsection.
1. Jaguar vehicles and replacement parts which contain asbestos are identified by this symbol. See Asbestos in
this subsection.

1. Components or assemblies displaying this symbol give warning that the component contains a corrosive
substance. See Acids and Alkalis in this subsection.

1. Vehicles displaying the caution circle with a deleted lighted match symbol, caution against the use of naked
lights or flames within the immediate vicinity due to the presence of highly flammable or explosive liquids or
vapors. See Fire in this subsection.

1. All vehicles with the passenger air bag installed from the factory have a warning sticker attached to the
instrument panel, prohibiting the use of rear facing child seats in the front seating position. Failure to follow
this instruction may result in personal injury.
White Spirit

See Solvents.

Safety Precautions
WARNINGS:

Working on the fuel system results in fuel and fuel vapor being present in the atmosphere. Fuel vapor is
extremely flammable, hence great care must be taken whilst working on the fuel system. Adhere strictly to the
following precautions:

Do not smoke in the work area


Display 'no smoking' signs around the area
Disconnect the battery before working on the fuel system
Do not connect/disconnect electrical circuits, use electrical equipment or other tools or engage in
working practices which in any way may result in the production of sparks
Ensure that a CO² fire extinguisher is close at hand
Ensure that dry sand is available to soak up any fuel spillage
Empty fuel using suitable fire proof equipment into an authorized explosion proof container
Do not empty fuel while working in a workshop or a pit
Ensure that working area is well ventilated
Ensure that any work on the fuel system is only carried out by experienced and well qualified
maintenance personnel
Ensure that fume extraction equipment is used where appropriate

Fume extraction equipment must be in operation when solvents are used e.g. Trichloroethane, white spirit,
sbp3, methylene chloride, perchlorethylene. Do not smoke in the vicinity of volatile degreasing agents.

Whenever possible, use a ramp or pit whilst working beneath a vehicle, in preference to jacking. Position chocks at
the wheels as well as applying the parking brake. Never rely on a jack alone to support a vehicle. Use axle stands, or
blocks carefully placed at the jacking points, to provide a rigid location. Check that any lifting equipment used has
adequate capacity and is fully serviceable. Ensure that a suitable form of fire extinguisher is conveniently located.
When using electrical tools and equipment, inspect the power lead for damage and check that it is properly earthed.
Disconnect the earth (grounded) terminal of the vehicle battery. Do not disconnect any pipes of the air conditioning
refrigeration system unless you are trained and instructed to do so. A refrigerant is used which can cause blindness if
allowed to come into contact with the eyes. Ensure that adequate ventilation is provided when volatile degreasing
agents are being used.

Adhere strictly to handling and safety instructions given on containers and labels. Keep oils and solvents away from
naked flames and other sources of ignition. Do not apply heat in an attempt to free seized nuts or fittings; as well as
causing damage to protective coatings, there is a risk of damage from stray heat to electronic equipment and brake
lines. Do not leave tools, equipment, spilt oil etc. around the work area. Wear protective overalls and use barrier
cream when necessary.

Environmental Protection

In some countries it is illegal to pour used oil onto the ground, down sewers or drains, or into water courses. The
burning of used engine oil in small space heaters or boilers is not recommended unless emission control equipment
is installed. Dispose of used oil through authorized waste disposal contractors, to licensed waste disposal sites or to
the waste oil reclamation trade. If in doubt, contact the Local Authority for advice on disposal facilities.
Published: 08-Dec-2012

2012.0 XF (X250), 100-00

General Information

How To Use This Manual (G539389)


DESCRIPTION AND OPERATION
Workshop Manual Organization

This manual covers descriptive, diagnostic (including OBD), and repair aspects to service the vehicle effectively.

The manual is arranged in sections, each section dealing with a specific part of a vehicle system. For example,
Section 412-03 [Air Conditioning] covers air conditioning, which is part of the climate control system.

The first digit of the section number indicates the group (in the above example this being Electrical). There are five
groups:

General Information.
Chassis.
Powertrain.
Electrical.
Body and Paint.

The second and third digits of the section number indicate the vehicle system (12 in the above example being
Climate Control).

The last two digits of the section number indicate the part of the system covered by the section (03 in the example
denotes Air Conditioning).
Published: 11-May-2011

2012.0 XF (X250), 100-00

General Information

Important Safety Instructions (G92207)


DESCRIPTION AND OPERATION
Safety Notice

Appropriate service methods and correct repair procedures are essential for the safe, reliable operation of all motor
vehicles, as well as the safety of the person doing the work. This manual provides general directions for
accomplishing service and repair work with tested effective techniques. Following them will help assure reliability.

There are numerous variations in procedures, techniques, tools, and parts for servicing vehicles, as well as in the
skill of the person doing the work. This manual cannot possibly anticipate all such variations and provide advice or
cautions as to each. Accordingly, anyone who departs from the instructions provided in the manual must first
establish that neither personal safety or vehicle integrity is compromised from choices of methods, tools or parts.
Published: 23-May-2018

2012.0 XF (X250), 100-00

General Information

Petrol and Petrol-Ethanol Fuel Systems Health and


Safety Precautions (G548996)
DESCRIPTION AND OPERATION
WARNINGS:

Fuel may not give adequate warning before toxic or harmful effects arise.

Exposure to fuel can be harmful and can cause severe health damage or death.

Extreme care must be exercised when handling hot fluids. Always wash off spilled fluids from affected areas
of skin immediately.

Highly flammable mixtures are always present and may ignite when working on fuel systems. Do not allow
naked flames, sparks or lighted substances to come near fuel related components.

Fuel must not be used as a cleaning agent.

Keep fuel containers tightly closed, out of direct sunlight and in a cool area. Keep away from heat sources,
ignition sources and oxidizing agents.

Residual pressure may still be present in the fuel system when disconnecting a fuel line. Make sure to cover
the fuel line connection with a lint free cloth to capture any escaping fuel.

SKIN CONTACT: Excessive or prolonged skin contact with diesel fuel may cause serious skin disorders
including skin cancer.

SKIN CONTACT: Fuel is mildly irritating to the skin and may cause dermatitis due to defatting effect.
Remove contaminated clothing. Wash affected areas of skin with soap and water. Seek medical attention for
any persistent skin irritation or abnormality. Wash contaminated clothing before reuse.

EYE CONTACT: Fuel is mildly irritating to the eyes. Flush with plenty of running water, blinking as often as
possible. Do not force the eyelid open. Seek medical attention for any persistent eye irritation or abnormality.

SWALLOWED: Fuel is moderately toxic and tends to foam on vomiting. If drawn into the lungs,
inflammation may develop. Do not induce vomiting. If spontaneous vomiting occurs place the victim in a
forward position to reduce the risk of fuel being drawn into the lungs. Give nothing by mouth. If breathing but
unconscious, place in the recovery position. If breathing has stopped, apply artificial respiration. Seek
immediate medical attention.

INHALED: Fuel is toxic to the respiratory and other body systems. Exposure may result in various symptoms
including drowsiness, unconsciousness or severe health damage. Move a victim to fresh air. Keep a victim
warm and at rest. If unconscious, place in the recovery position. If not breathing, apply artificial respiration.
Give cardiac massage if necessary. Seek immediate medical attention.

CAUTIONS:

Fuel injection equipment is manufactured to very precise tolerances and fine clearances. It is essential that
absolute cleanliness is observed when working with these components.
Make sure that the workshop area in which the vehicle is being worked on is as clean and as dust free as
possible.

Make sure the above warnings and cautions are correctly followed.
Published: 30-Nov-2018

2012.0 XF (X250), 100-00

General Information

Smart Key Transmission Frequency (G2325637)


DESCRIPTION AND OPERATION

Smart Key Transmission Frequency - 315 MHz

REGION Radio Frequency Ultra Wide Band Radio Frequency


Barbados - 800BC 315 MHz 3.9936 GHz
Bolivia 315 MHz 3.9936 GHz
Brazil - 800BH 315 MHz 3.9936 GHz
Cambodia 315 MHz 3.9936 GHz
Canada 800CB 315 MHz 3.9936 GHz
Cayman Islands 315 MHz 3.9936 GHz
Chile 800CG 315 MHz 3.9936 GHz
Colombia 800CJ 315 MHz 3.9936 GHz
Costa Rica 800CM 315 MHz 3.9936 GHz
Ecuador 800EA 315 MHz 3.9936 GHz
El Salvador 315 MHz 3.9936 GHz
Fiji 315 MHz 3.9936 GHz
Ghana 800GC 315 MHz 3.9936 GHz
Guam 315 MHz 3.9936 GHz
Guatemala 800GJ 315 MHz 3.9936 GHz
Haiti 315 MHz 3.9936 GHz
Honduras 315 MHz 3.9936 GHz
Jamaica 800JA 315 MHz 3.9936 GHz
Japan 800JB 315 MHz 3.9936 GHz
Malaysia 800MB 315 MHz 3.9936 GHz
Mexico 800MH 315 MHz 3.9936 GHz
Nicaragua 315 MHz 3.9936 GHz
Panama 800PB 315 MHz 3.9936 GHz
Paraguay 800PD 315 MHz 3.9936 GHz
Peru 800PE 315 MHz 3.9936 GHz
Puerto Rico 315 MHz 3.9936 GHz
Singapore 800MT 315 MHz 3.9936 GHz
Taiwan 800TB 315 MHz 4.4928 GHz
Thailand 800TD 315 MHz 3.9936 GHz
Trinidad & Tobago 315 MHz 3.9936 GHz
Uruguay 800UC 315 MHz 3.9936 GHz
USA 800UD 315 MHz 3.9936 GHz
Vietnam 800VB 315 MHz 4.4928 GHz
Zambia 800ZB 315 MHz 3.9936 GHz

Smart Key Transmission Frequency - 433.92 MHz

REGION Radio Frequency Ultra Wide Band Radio Frequency


Albania 800AC 433.92 MHz 3.9936 GHz
Algeria 800AD 433.92 MHz 3.9936 GHz
Andorra 433.92 MHz 3.9936 GHz
Angola 800AF 433.92 MHz 3.9936 GHz
Argentina 800AG 433.92 MHz 3.9936 GHz
Armenia 433.92 MHz 3.9936 GHz
Australia 800AJ 433.92 MHz 3.9936 GHz
Austria 800AK 433.92 MHz 3.9936 GHz
Azerbaijan 800AZ 433.92 MHz 3.9936 GHz
Bahrain 800BB 433.92 MHz 3.9936 GHz
Belarus 433.92 MHz 3.9936 GHz
Belgium 800BD 433.92 MHz 3.9936 GHz
Benin 433.92 MHz 3.9936 GHz
BES Islands (Netherlands Antilles) 433.92 MHz 3.9936 GHz
Bosnia 800BX 433.92 MHz 3.9936 GHz
Botswana 433.92 MHz 3.9936 GHz
Bulgaria 800BN 433.92 MHz 3.9936 GHz
Cameroon 433.92 MHz 3.9936 GHz
Canary Islands (Gran Canaria & Tenerife) 433.92 MHz 3.9936 GHz
Cape Verde 433.92 MHz 3.9936 GHz
Central African Republic 433.92 MHz 3.9936 GHz
China 800CH 433.92 MHz 4.4928 GHz
Croatia 800CP 433.92 MHz 3.9936 GHz
Curacao (Netherlands Antilles) 433.92 MHz 3.9936 GHz
Cyprus 800CS 433.92 MHz 3.9936 GHz
Czech Republic 433.92 MHz 3.9936 GHz
Denmark 800DB 433.92 MHz 3.9936 GHz
Dominican Republic 800DD 433.92 MHz 3.9936 GHz
Egypt 800EB 433.92 MHz 3.9936 GHz
Estonia 433.92 MHz 3.9936 GHz
Falkland Islands 800FK 433.92 MHz 3.9936 GHz
Finland 800FD 433.92 MHz 3.9936 GHz
France 800FF 433.92 MHz 3.9936 GHz
Georgia 800GR 433.92 MHz 3.9936 GHz
Germany 800GK 433.92 MHz 3.9936 GHz
Gibraltar 800GD 433.92 MHz 3.9936 GHz
Greece 800GF 433.92 MHz 3.9936 GHz
Guadeloupe 433.92 MHz 3.9936 GHz
Hong Kong 800HF 433.92 MHz 3.9936 GHz
Hungary 800HG 433.92 MHz 3.9936 GHz
Iceland 800IA 433.92 MHz 3.9936 GHz
India 800IC 433.92 MHz 3.9936 GHz
Indonesia 800ID 433.92 MHz 3.9936 GHz
Iran 800TQ 433.92 MHz 3.9936 GHz
Iraq 800IF 433.92 MHz 3.9936 GHz
Ireland 800IG 433.92 MHz 3.9936 GHz
Israel 800IH 433.92 MHz 3.9936 GHz
Italy 800IJ 433.92 MHz 3.9936 GHz
Ivory Coast (Côte d'Ivoire) 433.92 MHz 3.9936 GHz
Jordan 800JC 433.92 MHz 3.9936 GHz
Kazakhstan 800KZ 433.92 MHz 3.9936 GHz
Kenya 800KA 433.92 MHz 3.9936 GHz
Korea (South) 800KB 433.92 MHz 3.9936 GHz
Kuwait 800KC 433.92 MHz 3.9936 GHz
Laos 800LT 433.92 MHz 3.9936 GHz
Latvia 433.92 MHz 3.9936 GHz
Lebanon 800LB 433.92 MHz 3.9936 GHz
Liechtenstein 433.92 MHz 3.9936 GHz
Lithuania 433.92 MHz 3.9936 GHz
Luxembourg 433.92 MHz 3.9936 GHz
Macau 433.92 MHz 3.9936 GHz
Macedonia 800MY 433.92 MHz 3.9936 GHz
Malta 800MC 433.92 MHz 3.9936 GHz
Martinique 433.92 MHz 3.9936 GHz
Mauritius 800MF 433.92 MHz 3.9936 GHz
Moldova 800MV 433.92 MHz 3.9936 GHz
Mongolia 800MZ 433.92 MHz 3.9936 GHz
Morocco 800MJ 433.92 MHz 3.9936 GHz
Mozambique 433.92 MHz 3.9936 GHz
Myanmar (Burma) 433.92 MHz 3.9936 GHz
Netherlands 800NB 433.92 MHz 3.9936 GHz
Namibia 433.92 MHz 3.9936 GHz
New Caledonia 800NG 433.92 MHz 3.9936 GHz
New Zealand 800NK 433.92 MHz 3.9936 GHz
Nigeria 800NM 433.92 MHz 3.9936 GHz
Norway 800NQ 433.92 MHz 3.9936 GHz
Oman 800MS 433.92 MHz 3.9936 GHz
Pakistan 800PA 433.92 MHz 3.9936 GHz
Palestine 433.92 MHz 3.9936 GHz
Philippines 800PF 433.92 MHz 3.9936 GHz
Poland 800PG 433.92 MHz 3.9936 GHz
Portugal 800PH 433.92 MHz 3.9936 GHz
Qatar 800QA 433.92 MHz 3.9936 GHz
Reunion 433.92 MHz 3.9936 GHz
Romania 800RR 433.92 MHz 3.9936 GHz
Russia 800UE 433.92 MHz 3.9936 GHz
Saudi Arabia 800SC 433.92 MHz 3.9936 GHz
Senegal 433.92 MHz 3.9936 GHz
Serbia 800ER 433.92 MHz 3.9936 GHz
Sint Maarten 433.92 MHz 3.9936 GHz
Slovakia 800SW 433.92 MHz 3.9936 GHz
Slovenia 800SF 433.92 MHz 3.9936 GHz
South Africa 800SH 433.92 MHz 3.9936 GHz
Spain 800SK 433.92 MHz 3.9936 GHz
Sri Lanka 800CF 433.92 MHz 3.9936 GHz
Suriname 433.92 MHz 3.9936 GHz
Sweden 800ST 433.92 MHz 3.9936 GHz
Switzerland 800SU 433.92 MHz 3.9936 GHz
Tanzania 800TC 433.92 MHz 3.9936 GHz
Tunisia 800TF 433.92 MHz 3.9936 GHz
Turkey 800TG 433.92 MHz 3.9936 GHz
Turks and Caicos Islands 433.92 MHz 3.9936 GHz
Ukraine 800UK 433.92 MHz 3.9936 GHz
UAE 800UH 433.92 MHz 3.9936 GHz
United Kingdom 800UB 433.92 MHz 3.9936 GHz
Yemen 800YA 433.92 MHz 3.9936 GHz
Zimbabwe 800SX 433.92 MHz 3.9936 GHz
Published: 11-May-2011

2012.0 XF (X250), 100-00

General Information

Solvents, Sealants and Adhesives (G61152)


DESCRIPTION AND OPERATION
WARNING:

Always handle all solvents, sealers and adhesives with extreme care. Some contain chemicals or give off fumes
which can be dangerous to health. Always follow the manufacturers instructions. If in doubt about any substance,
particularly a solvent, DO NOT use it.

CAUTION:

If in doubt about the suitability of any proprietary solvent or sealer for a particular application, contact the
manufacturer of the product for information regarding storage, handling and application.

The Solvents, Sealers and Adhesives subsection refers to some commonly used chemicals and materials, hazards
associated with their use, and safety measures to be taken.

Adhesives and Sealers

Highly flammable, flammable, combustible – observe No Smoking policy.

Generally should be stored in No Smoking' areas. Cleanliness and tidiness in use should be observed e.g. disposable
paper covering benches; should be dispensed from applicators where possible; containers, including secondary
containers, should be labelled appropriately.

Solvent - based Adhesives/Sealers - See Solvents

Follow manufacturer's instructions.

Water - based Adhesives/Sealers

Those based on polymer emulsions and rubber latexes may contain small amounts of volatile toxic and harmful
chemicals. Skin and eye contact should be avoided and adequate ventilation provided during use.

Hot Melt Adhesives

In the solid state, they are safe. In the molten state they may cause burns and health hazards may arise from the
inhalation of toxic fumes.

Use appropriate protective clothing and a thermostatically controlled heater with a thermal cut - out and adequate
extraction.

Resin - based Adhesives/Sealers e.g. Epoxide and Formaldehyde Resin - based

Mixing should be carried out in well ventilated areas, as harmful or toxic volatile chemicals may be released.

Skin contact with uncured resins and hardeners can result in irritation, dermatitis, and absorption of toxic or harmful
chemicals through the skin. Splashes can damage the eyes.

Provide adequate ventilation and avoid skin and eye contact.


Anaerobic, Cyanoacrylate (Super - glues) and other Acrylic Adhesives

Many are irritant, sensitizing or harmful to the skin and/or respiratory tract. Some are eye irritants.

Skin and eye contact should be avoided and the manufacturer's instructions followed.

Cyanoacrylate adhesives (super-glues) MUST NOT contact the skin or eyes. If skin or eye tissue is bonded, cover
with a clean moist pad and seek immediate medical attention. Do not attempt to pull tissue apart. Use in well
ventilated areas as vapors can cause irritation to the nose and eyes.

For two - pack systems see Resin - based and Isocyanate Adhesives/Sealers.

Isocyanate (Polyurethane) Adhesives/Sealers

See also Resin - based Adhesives

Individuals suffering from asthma or respiratory allergies should not work with or near these materials as sensitivity
reactions can occur.

Over exposure is irritating to the eyes and respiratory system. Excessive concentrations may produce effects on the
nervous system including drowsiness. In extreme cases, loss of consciousness may result. Long term exposure to
vapor concentrations may result in adverse health effects.

Prolonged contact with the skin may lead to skin irritation and, in some cases, dermatitis.

Splashes entering the eye will cause discomfort and possible damage.

Any spraying should preferably be carried out in exhaust ventilated booths removing vapors and spray droplets from
the breathing zone.

Wear appropriate gloves, eye and respiratory protection.


Published: 05-Apr-2018

2012.0 XF (X250), 100-00

General Information

Standard Workshop Practices (G980021)


DESCRIPTION AND OPERATION
Protecting the Vehicle

Always install covers to protect the fenders before commencing work in the engine compartment. Always install the
interior protection kit, wear clean overalls and wash hands or wear gloves before working inside the vehicle. Avoid
spilling hydraulic fluid, antifreeze or battery acid on the paintwork. In the event of spillage, wash off with water
immediately. Use polythene sheets in the luggage compartment to protect carpets. Always use the recommended
service tool, or a satisfactory equivalent, where specified. Protect temporarily exposed screw threads by replacing
nuts or installing caps.

Vehicle in Workshop

When working on a vehicle in the workshop always make sure that:

The parking brake is applied or the wheels are securely chocked to prevent the vehicle moving forwards or
backwards
If the engine is to be run, there is adequate ventilation, or an extraction hose to remove exhaust fumes is
installed
There is adequate room to jack up the vehicle and remove the wheels, if necessary
Fender covers are always installed if any work is to be carried out in the engine compartment
The battery is disconnected if working on the engine, underneath the vehicle, or if the vehicle is jacked up

CAUTION:

When electric arc welding on a vehicle, always disconnect the generator wiring to prevent the possibility of a surge
of current causing damage to the internal components of the generator.

If using welding equipment on the vehicle, ensure a suitable fire extinguisher is readily available.

Screw Threads

Unless stated otherwise, self-locking nuts once removed must be discarded and new nuts of the same type
strength grade installed.
Damaged nuts, bolts and screws must always be discarded. Attempting to recut or repair damaged threads
with a tap or die impairs the strength and fit of the threads and is not recommended.

NOTES:

During certain repair operations, it may be necessary to remove traces of thread locking agents using a tap.
Where this is necessary, the instruction to do so will appear in the relevant operation and it is essential that a
tap of the correct size and thread is used.

New Taptite bolts when used cut their own threads on the first application.

Some bolts are coated with a thread locking agent and unless stated otherwise, they must not be reused. New
bolts having the same part number as the original must always be installed. When nuts or bolts are to be
discarded, the repair operation and relevant torque chart will include an instruction to that effect. Do not use
proprietary thread locking agents as they may not meet the specification required. See also Encapsulated
('Patched') Bolts and Screws.
Always make sure that replacement nuts and bolts are at least equal in strength to those that they are replacing.
Castellated nuts must not be loosened to accept a split pin except in recommended cases when this forms part
of an adjustment.
Do not allow oil or grease to enter blind holes, the hydraulic action resulting from tightening the bolt or stud
can split the housing and also give a false torque reading.
Always tighten a nut, bolt or screw to the specified torque figure, damaged or corroded threads can give a
false torque reading.
Nut and bolt loosening and tightening sequences, where given, must ALWAYS be followed. Distortion of
components or faulty sealing of joints will result if the sequences are not followed. Where an instruction is
given to tighten in stages, these stages must be adhered to; do not attempt to combine stages particularly where
certain stages involve tightening by degrees.
To check or re-tighten a fixing to a specified torque, first loosen a quarter of a turn, then re-tighten to the
specified torque figure.
Unless instructed otherwise, do not lubricate bolt or nut threads prior to installing.

Where it is stated that bolts and screws may be reused, the following procedures must be carried out:

Check that threads are undamaged.


Remove all traces of locking agent from the threads.

CAUTION:

DO NOT use a wire brush; take care that threads are not damaged.

Make sure that threads are clean and free from oil or grease.
Apply the specified locking agent to the bolt threads if required.

Supplementary Restraint System (SRS) Precautions


WARNING:

Do not install rear facing child seats in the front passenger seat.

The SRS contains components which are potentially hazardous to service personnel if not handled correctly. The
following guidelines and precautions are intended to alert personnel to potential sources of danger and emphasise the
importance of ensuring the integrity of the SRS components installed to the vehicle.

WARNING:

The following precautions MUST be adhered to when working on the SRS system:

The correct procedures must always be used when working on SRS components.
Persons working on the SRS system must be fully trained and have been issued with the safety guidelines.
The airbag modules contain extremely flammable and hazardous compounds. Contact with water, acids or
heavy metals may produce harmful or explosive results. Do not dismantle, incinerate or bring into contact
with electricity before the unit has been deployed.
Always replace a seat belt assembly that has withstood the strain of a severe vehicle impact or if the webbing
shows signs of fraying.
Always disconnect the vehicle battery before carrying out any electric welding on a vehicle installed with an
SRS system.

CAUTION:

Do not expose airbag modules or seat belt pre-tensioners to temperatures exceeding 85° C (185° F).

It should be noted that these precautions are not restricted to operations performed when servicing the SRS system.
The same care should be exercised when working on ancillary systems and components located in the vicinity of
SRS components; these include but are not limited to:
Steering wheel airbag, rotary coupler.
Passenger front airbag.
Head airbag modules - front and rear.
Seat belt pre-tensioners.
SRS harnesses, link leads and connectors.
Side (thorax) air bags.

Making the system safe

Before working on or in the vicinity of SRS components, make sure the system is rendered safe by performing the
following operations:

Remove the ignition key.


Disconnect battery, earth lead first.
Wait 2 minutes for the SRS power circuit to discharge before commencing work.

NOTE:

The SRS uses energy reserve capacitors to keep the system active in the event of electrical supply failure under crash
conditions. It is necessary to allow the capacitors sufficient time to discharge (2 minutes) in order to avoid the risk of
accidental deployment.

Installation

In order to make sure system integrity, it is essential that the SRS system is regularly checked and maintained so that
it is ready for effective operation in the event of a collision. Carefully inspect SRS components before installation.
Do not install a part that shows signs of being dropped or improperly handled, such as dents, cracks or deformation.

WARNING:

The integrity of the SRS systems is critical for safety reasons. Make sure the following precautions are always
adhered to:

Do not install accessories or other objects to trim panels which cover ITS airbags.
Never install used SRS components from another vehicle or attempt to repair an SRS component.
When repairing an SRS system, only use genuine new parts.
Never apply electrical power to an SRS component unless instructed to do so as part of an approved test
procedure.
Special fixings are necessary for installing an airbag module – do not use other fixings and make sure that all
fixings are tightened to the correct torque.
Always use new fixings when replacing an SRS component.

CAUTIONS:

Take care not to trap airbag modules when installing interior trim components.

Make sure SRS components are not contaminated by oil or grease.

NOTES:

Following seat belt pre-tensioner deployment, the seat belts can still be used as conventional seat belts but will
need to be replaced as soon as possible to make sure full SRS protection.

If the SRS components are to be replaced, the part number/bar code of the new unit must be recorded.

SRS component testing precautions

The SRS components are triggered using relatively low operating currents, always adhere to the following :
WARNING:

Never use a multimeter or other general purpose equipment on SRS components. Use only approved JLR diagnostic
equipment to diagnose system faults.

WARNING:

Do not use electrical test equipment on the SRS harness while it is connected to any of the SRS components, it may
cause accidental deployment and injury.

Handling and storage

Always observe the following precautions when handling SRS components:

Never drop an SRS component. The airbag diagnostic control unit is a particularly shock sensitive device and
must be handled with extreme care. Airbag modules and seat belt pre-tensioners could deploy if subjected to a
strong shock.
Never wrap your arms around an airbag module. If a module has to be carried, hold it by the cover with the
cover uppermost and the base away from your body.
Never transport airbag modules or seat belt pre-tensioner in the passenger compartment of a vehicle. Always
use the luggage compartment of the vehicle for carrying airbag modules and seat belt pre-tensioner units.
Never attach anything to an airbag cover or any trim component covering an airbag module. Do not allow
anything to rest on top of an airbag module.
Always keep components cool, dry and free from contamination.
Never apply grease or cleaning solvents to seat belt pre-tensioner units, component failure could result.
Always store an airbag module with the deployment side uppermost. If it is stored deployment side down,
accidental deployment will propel the airbag module with sufficient force to cause serious injury.
Keep new airbag modules in their original packaging until just prior to installing. Place the old module in the
empty packaging for carriage.
WARNINGS:

When handling an inflatable tubular structure (ITS) airbag module, hold by the gas generator housing, DO
NOT hold by the airbag. Do not wrap the thumb around the gas generator while holding. Do not drape airbag
over shoulder or around neck. For seat buckle type pre-tensioners, hold by the piston tube, with the open end
of the piston tube pointing towards the ground and the buckle facing away from your body. Do not cover the
end of the piston tube. DO NOT hold buckle type pre-tensioners by the bracket assembly or cable. Never point
the piston tube towards your body or other people.

Airbag modules and seat belt pre-tensioners are classed as explosive devices. For overnight and longer term
storage, they must be stored in a secure steel cabinet which has been approved as suitable for the purpose and
has been registered with the local authority.

Store airbag modules or seat belt pre-tensioners in a designated storage area. If there is no designated storage
area available, store in the locked luggage compartment of the vehicle and inform the workshop supervisor.

CAUTION:

Improper handling or storage can internally damage the airbag module making it inoperative. If you suspect the
airbag module has been damaged, install a new module and refer to the deployment/disposal procedures for disposal
of the damaged module.

SRS harness and connectors

Always observe the following precautions with regards to SRS system electrical wiring:

SRS firing circuit wiring may only be repaired using the approved repair kit in accordance with the correct
instructions. For additional information, refer to: Wiring Harness (418-02 Wiring Harnesses, Description and
Operation).
Never install electrical equipment such as a mobile telephone, two-way radio or in-car entertainment system in
such a way that it could generate electrical interference in the airbag harness. Seek specialist advice when
installing such equipment.

NOTE:

SRS wiring can be identified by a special yellow outer sleeve protecting the wires (black with yellow stripe
protective coverings are sometimes used).
WARNING:

Always make sure SRS wiring is routed correctly. Be careful to avoid trapping or pinching the SRS wiring.

WARNING:

Do not leave the connectors hanging loose or allow SRS components to hang from their harnesses. Look for possible
chafing points.

Side impact crash sensor inspection

After any degree of side body damage, inspect the side impact crash sensors. Replace a crash sensor if there is any
sign of damage.

CAUTION:

Take extra care when painting or carrying out bodywork repairs in the vicinity of the crash sensors. Avoid direct
exposure of the crash sensors or link harnesses to heat guns, welding or spraying equipment. Take care not to
damage sensor or harness when reinstalling components.

Rotary coupler

CAUTION:

Always follow the procedure for installing and checking the rotary coupler as instructed in the SRS repairs section.
Comply with all safety and installation procedures to make sure the system functions correctly. Observe the
following precautions:

Do not unlock and rotate the rotary coupler when it is removed from the vehicle.
Do not turn the road wheels when the rotary coupler is removed from the vehicle.
Always make sure the rotary coupler is removed and installed in its central position and with the front road
wheels in the straight ahead position - refer to SRS repair section for the correct removal and installation
procedure.
If a new rotary coupler is being installed, make sure the locking tab holding the coupler's rotational position is
not broken; units with a broken locking tab must not be used.
Airbag location labels

WAITING AIRBAG LOCATION AND DESIGN LABELS - DUE MARCH - NEIL HARRISON 46404

Airbag and pre-tensioner deployment


WARNING:

During deployment parts of the airbag module become hot enough to burn you. Wait 30 minutes after deployment
before touching the airbag module.

Deployment procedures and precautions as detailed in this manual should be strictly adhered to. Only personnel who
have undergone the appropriate training should undertake deployment of airbag and pre-tensioner modules. The
following precautions must be complied with:

Only use deployment equipment approved for the intended purpose.


Deployment of airbag / pre-tensioner modules must be performed in a well ventilated area which has been
designated for the purpose.
Make sure airbag / pre-tensioner modules are not damaged or ruptured before attempting to deploy.
Where local legislation exists, notify the relevant authorities of intention to deploy airbag and pretensioner
units.
When deploying airbag pre-tensioner units, make sure that all personnel are at least 15 metres (45 feet) away
from the deployment zone.
Make sure deployment tool is connected correctly, in compliance with the instructions detailed in the SRS
section of this manual. In particular, make sure deployment tool is NOT connected to battery supply before
connecting to airbag module connector.
When deploying seat belt pre-tensioners, make sure pre-tensioner unit is secured correctly to the seat.
When removing deployed airbag modules and pre-tensioner units, wear protective clothing. Use gloves and
seal deployed units in a plastic bag.
Following deployment of any component of the SRS system within the vehicle, all SRS components must be
replaced. DO NOT reuse or salvage any parts of the SRS system.
Do not lean over an airbag module when connecting deployment equipment.

If a vehicle is to be scrapped, undeployed airbag modules and pre-tensioner units must be manually deployed. In this
case airbags can be deployed in the vehicle. Before deployment, make sure the airbag module is secure within its
correct mounting position. Deployment of the driver's airbag in the vehicle may damage the steering wheel; if the
vehicle is not being scrapped, deploy the module outside of the vehicle.

SRS Component Replacement Policy


CAUTIONS:

The Restraints Control Module (RCM) will log a crash fault after every impact which is severe enough to
cause airbag deployment. It is possible to have three crashes/impacts logged after one event where, for
example, a front, side and rollover has occurred. After the third fault is logged, the SRS warning lamp will be
illuminated and the RCM must be installed. After any airbag deployment a new RCM must be installed.

The SRS side impact sensor must be replaced if there are any signs of physical damage or if the restraints
control module (RCM) is registering a fault.

The following information details the policy for replacement of SRS components as a result of a vehicle accident.

Impacts which do not deploy the airbags or pre-tensioners

Check for structural damage in the area of the impact paying particular attention to bumper armatures, longitudinals
and bracketry.

Impacts which deploy the airbags or pre-tensioners

The replacement and inspection policy is dependent on the type and severity of the crash condition. The following
guidelines are the minimum that should be exercised as a result of the deployment of specific SRS components.
Check for structural damage in the area of impact paying particular attention to bumper armatures, longitudinals and
bracketry.

Front Airbag Deployment - Driver and Passenger


CAUTION:

If the front airbags are deployed, the following components must be replaced:

Driver airbag module


Passenger airbag module
Fly leads (where applicable) connecting front airbag modules to SRS harness
Front seat belt buckle pre-tensioner
Rear seat belt pre-tensioners - if installed
Driver's seat belt retractor - if installed
Rotary coupler
Any front impact sensors that have been physically damaged or if a fault is being registered
Restraints control module (RCM) if the three crashes/impacts have been stored

Additionally, the following items must be inspected for damage and replaced as necessary:

Front passenger's seat belt retractor and webbing, tongue latching function, 'D' loop and body anchorage point
Rear seat belt buckles, webbing, buckle covers, body anchorage points and tongue latching function
Fascia moulding adjacent to passenger airbag module
Steering wheel
Front seat frames and head restraints
Steering column - if adjustment is lost or if there are signs of collapse
Seat belt height adjusters
Rear seat belts

Side Air Bags

CAUTION:

If the side (thorax) air bags are deployed, the following components must be replaced on the side of the vehicle on
which the deployment occurred:

Side (thorax) airbag


Any side impact sensors that have been physically damaged or if a fault is being registered
Restraints Control Module (RCM) if the three crashes/impacts have been stored

Additionally, the following items must be inspected for damage and replaced as necessary:

Front seat belts, retractors and webbing, tongue latching function, 'D' loop and body anchorage points
Rear seat belt buckles, webbing, buckle covers, tongue latching function, and body anchorage points
Front seat frame and head restraints
Door trim casing
Seat belt height adjusters
Rear seat belts

Head airbag modules

CAUTION:

If the head airbag modules are deployed, the following components must be replaced on the side of the vehicle on
which the deployment occurred:

Head airbag modules


Link lead between airbag gas generator and restraints control module (RCM) harness
Airbag retaining clips
Internal trim finisher
Front seat belt buckle pre-tensioners
Any side impact sensors that have been physically damaged or if a fault is being registered
Restraints Control Module (RCM) if the three crashes/impacts have been stored

Additionally, the following items must be inspected for damage and replaced as necessary:

Headlining
Component mounting brackets
Front seat belts, retractors and webbing, tongue latching function, 'D' loop and body anchorage points
Rear seat belt buckles, webbing, buckle covers, tongue latching function, and body anchorage points
Adjacent trim components
Seat belt height adjusters

Rear impacts

CAUTION:

If the seat belt pre-tensioners are deployed during a rear impact, the following components must be replaced:

Seat belt pre-tensioners


Front and rear seat belt retractors used during the impact
Restraints Control Module (RCM) if the three crashes/impacts have been stored

Additionally, the following items must be inspected for damage and replaced as necessary:

Seat belt height adjusters


Front seat belts, retractors and webbing, tongue latching function, 'D' loop and body anchorage points
Rear seat belt buckles, webbing, buckle covers, tongue latching function, and body anchorage points
Published: 11-May-2011

2012.0 XF (X250), 100-00

General Information

Symbols Glossary (G955392)


DESCRIPTION AND OPERATION

Symbols are used inside the graphics and in the text area to enhance the information display.

Movement Symbols

Movement symbols provide detailed information to a required component movement. These component movements
can be rotational or 1-3 dimensional movements.

Item Description
1 Minor component movement clockwise/counterclockwise
2 Major component movement clockwise/counterclockwise
3 Component movement to the left/right/up/down
4 Component movement towards/away
5 3 dimensional component movement
6 2 dimensional component movement
7 3 dimensional component rotation
8 3 dimensional component cycling
Turn Symbols

Turn symbols are used to provide further information on the direction or angle of component turns.

Item Description
1 Turn the component clockwise through 45°
2 Turn the component counterclockwise through 45°
3 Turn the component clockwise through 90°
4 Turn the component counterclockwise through 90°
5 Turn the component clockwise through 180°
6 Turn the component counterclockwise through 180°
7 Turn the component clockwise through 2 complete turns
8 Turn the component counterclockwise through 2 complete turns
Steering Wheel Symbols

Steering wheel symbols are used to provide further information to a required steering wheel position or steering
column lock status.

Item Description
1 Steering wheel in straight ahead position
2 Steering column lock locked
3 Steering column lock unlocked
4 Turn the steering wheel to the 90° left position
5 Turn the steering wheel to the 90° right position
6 Turn the steering wheel to the left-hand end position
7 Turn the steering wheel to the right-hand end position

Item Description
1 3, 4, 5-door body style
2 Wagon body style
3 Sports utility vehicle body style
4 Coupe body style
5 Convertible body style
6 Van body style
7 3, 4, 5-door body style - Top View
8 Wagon body style - Top View
9 Underview
10 Right-hand drive (RHD) vehicle
11 Left-hand drive (LHD) vehicle
Gearshift lever and selector lever position symbols

Gearshift lever and selector lever position symbols are used to show the lever position that is required to be selected
to carry out a procedure step.

Item Description
1 Set the selector lever to the park (P) position
2 Set the selector lever to the reverse ®) position
3 Set the selector lever to the neutral (N) position
4 Set the selector lever to the drive (D) position
5 Set the selector lever with manual shift pattern to the park (D) position
6 Set the selector lever with manual shift pattern to the manual (M) position
7 Set the selector lever with manual shift pattern to the shift down (-) position
8 Set the selector lever with manual shift pattern to the shift up (+) position
9 Set the gearshift lever to the neutral (N) position
10 Further gearshift lever positions that may appear in illustrations
Screwdriver symbols

The screwdriver symbols are used to show which screwdriver bit is recommended to carry out a procedure step.
Item Description
1 Screwdriver
2 Cross bladed screwdriver
3 Flat bladed screwdriver
4 Hexagonal screwdriver
5 TORX screwdriver
Pliers symbols

The pliers symbols are used to show which pliers is recommended to carry out a procedure step.
Item Description
1 Combination pliers
2 Side cutter pliers
3 Securing ring pliers - inner
4 Securing ring pliers - outer
5 Hose clamp pliers
6 Locking pliers
7 Long nose pliers
Drill symbols
The drill symbols are used to show which type and size of drill bit is recommended to carry out a procedure step.

Item Description
1 Drill bit with a specified diameter
2 Hole saw with a specified diameter
3 Stepped drill bit with a specified diameter
4 Tap with a specified diameter
5 Die with a specified diameter
6 Scraper for circular holes
7 Scraper for straight edges
Cutting tool symbols

The cutting tool symbols are used to show which type of cutting tool is recommended to carry out a procedure step.
Item Description
1 Cutting knife
2 Air body saw
3 Scissors
4 Grinder
5 Jig saw
6 Plasma cutter
7 Sanding Paper
8 Drill through the shown number of body panel layers with a specified diameter
9 Drill through the shown number of body panel layers with a suitable diameter
10 Drill through 1 body panel layer with a specified diameter
11 Drill through 1 body panel layer with a suitable diameter
12 Wire brush
Apply Chemical or load symbols

The apply chemical or load symbols are used to show where to apply which type of chemical or load to carry out a
procedure step.

Item Description
1 Apply a bead from the specified tube
2 Apply a bead from the specified cartridge
3 Apply the specified chemical with a brush
4 Apply the specified load to the specified component
5 Apply a bead with a specific diameter from the specified tube
6 Apply a bead with a specific diameter from the specified cartridge
7 Apply the specified chemical with a roller
8 Apply hot glue to the specified component
9 Apply the specified amount of fluid from the fluid can
10 Apply fluid from the fluid can
11 Clean the specified component with the specified material
12 Apply a broken bead from the specified tube
13 Apply the specified chemical from a spray can
14 Apply the specified lubricant to the specified component
15 Apply spot welds to the specified component
16 Apply a continuous weld to the specified component
17 Handle the fluid using a syringe
18 Extract the specified amount of fluid using a syringe
Measurement symbols

The measurement symbols are used to show where to measure which type of measurement to carry out a procedure
step.
Item Description
1 Measure the current using a digital multimeter
2 Measure the voltage using a digital multimeter
3 Measure the resistance using a digital multimeter
4 Measure the length/distance
5 Check that the specified pressure is available using a suitable pressure gauge
6 Measure the pressure at the specified port using a suitable pressure gauge
7 Measure the time using a suitable stopwatch
8 Wait for the specified period of time
9 The specified task requires the specified minimum temperature
10 The specified task requires the specified maximum temperature not to be exceeded
11 The specified task requires the specified temperature range
12 The specified task requires the specified temperature
13 Measure and check for the specified value using a dial indicator gauge
14 Measure and check for the specified MAX value using a dial indicator gauge
15 Measure and check for the specified MIN value using a dial indicator gauge
General equipment symbols

The general equipment symbols are used to show where to use which type of general equipment to carry out a
procedure step.
Item Description
1 Hot air gun
2 Soldering iron
3 Scraper
4 Scriber
5 Securing strap
6 File with a specified size
7 Center punch
8 Marker
9 Metal inert gas (MIG) welding equipment
10 Hose clamp
11 Interior trim remover
12 Vacuum cleaner
13 Strap wrench
14 Wedge
15 Pin Punch
Material symbols

The material symbols are used to show where to use which type of material to carry out a procedure step.

Item Description
1 Remove/Install the specified blind rivet
2 Apply tape to the specified component/area
3 Remove/Install the specified cable tie
Miscellaneous symbols

These symbols provide further information that is required to carry out a procedure step.
Item Description
1 Set the ignition switch to the 0 position
2 Set the ignition switch to the II position
3 The procedure step requires the aid of the specified number of supporting technicians
4 Self contained breathing apparatus
5 General prohibition used in combination with another symbol
6 Do not use power tools
7 Visual check
8 Noise check
9 Dispose the specified component
10 Replaced by item 9 (Dispose the specified component)
11 Set the engine speed to the specified value
12 Fully apply the parking brake lever
13 Fully release the parking brake lever
14 Do not dispose of batteries into the waste bin
15 Visual check using a mirror
16 Area/component must be dry
Mandatory Protective equipment - Health and safety symbols

The protective equipment symbols advise to use a mandatory protective equipment to avoid or at least reduce
possible health and safety risks.

Item Description
1 Wear protective gloves
2 Wear face guard
3 Wear safety goggles
4 Wear ear protectors
5 Wear safety goggles and ear protectors
6 Wear a respirator
Prohibition - Health and safety symbols and component damage

The prohibition symbols are used to prohibit the specified actions to avoid or at least reduce possible component
damage and health and safety risks.

Item Description
1 General prohibition symbol
2 No naked flames
3 No smoking
4 No water
5 Do not touch
6 Do not switch
7 No grinding
Warning symbols - Health and safety and component damage
The warning symbols are used to advise on hazardous conditions to avoid or at least reduce possible component
damage and health and safety risks.

Item Description
1 Hazardous voltage/Electrical shock/Electrocution
2 Fire Hazard/Highly flammable
3 Burn hazard/Hot surface
4 Automatic start-up
5 Toxic
6 Explosive material
7 Battery hazard
8 Corrosive material
9 Lifting hazard
10 Hand crush/Force from above
11 Cutting of fingers or hand
12 Pressure hazard
Control Diagram symbols - Description and Operation procedures
These symbols provide further information on the type of connectivity, direction of flow or type of data bus of a
system.

Item Description
1 Mid-speed Controller Area Network (CAN)
2 High-speed Controller Area Network (CAN)
3 Local Interconnect Network (LIN)
4 Wires crossing not connected
Published: 15-Sep-2021

2012.0 XF (X250), 100-00

General Information

Supplementary Restraint System Health and Safety


Precautions (G548998)
DESCRIPTION AND OPERATION
WARNINGS:

Only qualified technicians are allowed to work on pyrotechnic components.

INHALED: Exposure to pyrotechnic residue may cause low blood pressure, severe headache, irritation of
mucous membranes, fainting, shortness of breath or rapid pulse. Move a victim to fresh air. Seek immediate
medical attention.

EYE CONTACT: Exposure to unburned pyrotechnic residue may cause irritation, burning and etching of the
eyes. Flush immediately with plenty of cold running water for at least 15 minutes. Seek immediate medical
attention.

EYE CONTACT: Exposure to burned pyrotechnic residue may cause irritation, burning and etching of the
eyes. Flush immediately with diluted boric acid solution. Seek immediate medical attention.

SKIN CONTACT: Unburned pyrotechnic residue may be rapidly absorbed through the skin in toxic
quantities. Wash immediately with plenty of soap and water. Seek medical attention.

SKIN CONTACT: Burned pyrotechnic residue may be rapidly absorbed through the skin in toxic quantities.
Wash with plenty of water. Do not use soap. Seek medical attention.

SWALLOWED: Unburned pyrotechnic residue is extremely toxic. If conscious drink plenty of water then
induce vomiting. Seek immediate medical attention. If unconscious, or in convulsions do not attempt to induce
vomiting or give anything by mouth. Seek immediate medical attention.

SWALLOWED: Burned pyrotechnic residue is extremely toxic. Drink plenty of water and seek immediate
medical attention.

The deployment key must only be accessible to authorized personnel.

Make sure that the deployment key remains removed from the deployment equipment except during
deployment.

If permenantly disabling or enabling the passenger airbag a new seatbelt for vehicles without or with a
passenger airbag must be installed.

Undeployed pyrotechnic components must not be deployed in the vehicle.

Pyrotechnic components must be deployed following local regulations.

Check thoroughly that no loose objects can be spread during the deployment of pyrotechnic components.

Pyrotechnic components must be transported following local regulations.

Never do any electrical measurement on disconnected, undeployed pyrotechnic components.


Pyrotechnic components must not be disassembled.

Pyrotechnic components are not interchangeable between vehicles.

Always carry a live airbag module away from the body with the airbag or trim cover pointing upwards.

Live airbag modules must be placed in a suitable cage when removed from the vehicle. The airbag or trim
cover must be facing upwards.

Do not install a rearward facing child safety seat to the passenger seat with an activated passenger airbag.

CAUTIONS:

Pyrotechnic components must not be subjected to temperatures higher than 110°C.

Never install aftermarket accessories to the vehicle on or adjacent to the supplemental restraint system
module.

Note: Refer to this document before carrying out any work on the Supplementary Restraint System (SRS).
Published: 11-May-2011

2012.0 XF (X250), 100-00

General Information

Road/Roller Testing (G539390)


DESCRIPTION AND OPERATION

Road or roller testing may be carried out for various reasons and a procedure detailing pre-test checks, through
engine starting and stopping, pre-driving checks, on-test checks to final checks on completion of the test is given in
this section.

Unless complete vehicle performance is being checked, the full road test procedure need not be carried out. Instead,
those items particularly relevant to the system/s being checked can be extracted.

Pre - Test Checks


WARNING:

If the brake system hydraulic fluid level is low, pedal travel is excessive or a hydraulic leak is found, do not attempt
to road test the vehicle until the reason for the low fluid level, excessive pedal travel or hydraulic leak is found and
rectified.

It is suggested that pre-test checks, and functional tests of those systems/circuits which affect the safe and legal
operations of the vehicle, such as brakes, lights and steering, should always be carried out before the road or roller
test.

Engine oil level


Engine coolant level
Tires, for correct pressure, compatible types and tread patterns, and wear within limits
There is sufficient fuel in the tank to complete the test
All around the engine, transmission and under the vehicle for oil, coolant, hydraulic and fuel leaks. Make a
note of any apparent leaks and wipe off the surrounding areas to make it easier to identify the extent of the
leak on completion of the test

Starting the Engine


CAUTION:

On initial drive away from cold and within the first 1.5 km (1 mile), do not depress accelerator pedal beyond half
travel until the vehicle has attained a minimum speed of 25 km/h (15 miles/h). Never operate at high engine speed or
with the accelerator pedal at full travel whilst the engine is cold.

With the ignition switched off, check:

The parking brake is applied


The transmission selector lever is in Park
All instrument gauges (except fuel gauge) read zero

With the ignition switched on, check:

Ignition controlled warning lamps come on


Engine coolant temperature gauge registers a reading compatible with the engine coolant temperature
Fuel gauge registers a reading appropriate to the fuel level in the tank
The operation of the parking brake and brake fluid level warning lamps
On Road or Roller Test Check:
CAUTION:

If road testing, check the brake operation while still travelling at low speed before continuing with the test. If the
brakes pull to one side, or appear to be otherwise faulty, do not continue with the road test until the fault has been
found and rectified.

Initial gear engagement is smooth


Parking brake control operates smoothly and the parking brake releases quickly and completely
Transmission takes up the drive smoothly, without judder
The engine power output is satisfactory, full power is achieved, acceleration is smooth and pedal operation not
stiff or heavy, and engine speed returns to idle correctly
There is no excessive or abnormally colored smoke from the engine under normal driving, heavy load or
overrun conditions
Steering operation, including power steering, is smooth, accurate, not excessively heavy or with excessive free
play or vibration. Does not pull to one side and self centres smoothly after cornering
Speedometer, oil pressure warning lamp, coolant temperature gauge and tachometer register the correct
readings or operate correctly
Switches and controls operate smoothly and positively, warning lamps operate correctly and the direction
indicator control self cancels when the steering is returned to the straight ahead position
Heating and ventilation systems work correctly and effectively
Brake operation and efficiency

Brake Testing
WARNING:

When brake testing, avoid breathing the smoke or fumes from hot brakes, this may contain asbestos dust which is
hazardous to health, see Health and Safety Precautions.

Avoid brake testing on busy roads where it can cause inconvenience or danger to other road users.

CAUTION:

Brake testing which includes heavy brake applications should not be carried out with new brake pads/discs or
linings/drums until the components have bedded-in. New brake friction components will not reach full efficiency
until the bedding-in process is complete.

Test the brakes at several speeds within the normal operating range using both light and heavy pedal pressure. Note
any tendency to snatch, pull or drag, and any undue delay in application or release.

Allow the vehicle to coast and note any tendency to pull to one side, or evidence that the brakes are binding.

After stopping the vehicle (not immediately after a period of heavy braking), carefully check the brake temperature.
A disc which feels hot, or appreciably hotter than the others, indicates that the brake is binding.

After completion of the test, check for:

Oil, coolant, hydraulic, air and fuel leaks


Abnormal temperature of any moving components or assemblies, e.g. wheel hubs, transmission, axle etc.,
which might indicate over tightness or lack of lubrication
Published: 11-May-2011

2012.0 XF (X250), 100-00

General Information

Window Glass Health and Safety Precautions (G548999)


DESCRIPTION AND OPERATION
WARNINGS:

Cured polyurethane (PU) adhesive can degrade if subjected to high temperatures. Isocyanide compounds can
be released when grinding or welding in close proximity to cured PU adhesive.

SKIN CONTACT: Prolonged exposure to polyurethane (PU) adhesive may cause skin irritation. If PU
adhesive comes into contact with the skin, remove any contaminated clothing. Immediately wash the skin with
soap and water. Seek medical attention for any persistent skin irritation or abnormality.

EYE CONTACT: Polyurethane (PU) adhesive may cause severe irritation or damage. If PU adhesive comes
into contact with the eyes, immediately flush eyes with plenty of running water for at least 15 minutes. Seek
immediate medical attention.

SWALLOWED: If polyurethane (PU) adhesive is swallowed, flush the mouth thoroughly. Do not induce
vomiting. Provide rest, warmth and fresh air. Seek immediate medical attention.

INHALED: Persons having a respiratory allergy may have an allergic reaction when handling polyurethane
(PU) adhesive.

INHALED: Polyurethane (PU) adhesive can cause asthma like symptoms. Isocyanate vapor from primer or
PU adhesive can cause allergies in the respiratory tract.

INHALED: If polyurethane (PU) adhesive fumes are inhaled, move victim to fresh air. Provide oxygen if
necessary. If breathing stops, provide artificial respiration. Keep a victim warm and at rest. Seek immediate
medical attention.

CAUTIONS:

Make sure that the direct glazing for bonded glass cutting blades are changed where the cutting depth changes
to avoid damage to the body and trim panels.

During the curing period of the PU adhesive, the door windows must be left open to avoid a build up of
pressure when the doors are opened and closed.
Published: 17-Apr-2014

2012.0 XF (X250), 100-00

General Information

Diagnostic Trouble Code Index - DTC: Active Safety


Belt Module (SPMA/SPMB) (G1426773)
DESCRIPTION AND OPERATION
Active Safety Belt Module (SPMA/SPMB)
CAUTION:

Diagnosis by substitution from a donor vehicle is NOT acceptable. Substitution of control modules does not
guarantee confirmation of a fault and may also cause additional faults in the vehicle being checked and/or the donor
vehicle.

NOTES:

If the control module or a component is suspect and the vehicle remains under manufacturer warranty, refer to
the Warranty Policy and Procedures manual, or determine if any prior approval programme is in operation,
prior to the installation of a new module/component.

Generic scan tools may not read the codes listed, or may read only 5-digit codes. Match the 5 digits from the
scan tool to the first 5 digits of the 7-digit code listed to identify the fault (the last 2 digits give extra
information read by the manufacturer approved diagnostic system).

When performing voltage or resistance tests, always use a digital multimeter accurate to three decimal places
and with a current calibration certificate. When testing resistance, always take the resistance of the digital
multimeter leads into account.

Check and rectify basic faults before beginning diagnostic routines involving pinpoint tests.

If DTCs are recorded and, after performing the pinpoint tests a fault is not present, an intermittent concern
may be the cause. Always check for loose connections and corroded terminals.

Where an 'on demand self-test' is referred to, this can be accessed via the 'DTC Monitor' tab on the
manufacturers approved diagnostic system.

Check DDW for open campaigns. Refer to the corresponding bulletins and SSMs which may be valid for the
specific customer complaint and carry out the recommendations as required.

The table below lists all Diagnostic Trouble Codes (DTCs) that could be logged in the Active Safety Belt Module,
for additional Diagnosis and Testing information refer to the relevant Diagnosis and Testing Section. For additional
information, refer to: Airbag and Safety Belt Pretensioner Supplemental Restraint System (501-20B Supplementary
Restraint System, Diagnosis and Testing).

DTC Description Possible Causes Action


U1A14- CAN Power Refer to the electrical circuit diagrams and check the power
00 Initialization distribution and ground connections to the module. Using the
Failure - No fault to control manufacturer approved diagnostic system, complete a CAN
sub type module network integrity test. Refer to the electrical circuit
information CAN network diagrams and check the CAN network. After installing a
fault new control module, updating software or repairing a wiring
harness perform an On Demand Self Test and Retract and
Release Self Test using the manufacturers approved
diagnostic system

U2001- Reduced Seat belt NOTE:


68 System retractor
Function - mechanism If required, it is only necessary to install a new component on the
Event has exceeded side affected by the DTC.
information the design
limit for the Confirm the Safety belt retractor mechanism has exceeded
durability the design limit for durability by interrogating the Active
Safety Belt Module. Using the manufacturer approved
diagnostic system check the Dynamic Safety belt Health
Status at PID5824, if the Safety belt status is confirmed as
'not healthy' (01) install a new retractor mechanism as
required. If the Safety belt status is 'healthy' (00) clear the
DTC and Refer to the workshop manual section 501-20A
and perform the Retract and Release Self Test using the
manufacturers approved diagnostic system. Refer to the
Warranty Policy and Procedures manual if a
module/component is suspect

U2101- Control Module The control Check the vehicle configuration file to ensure the vehicle
00 Configuration module is not configuration is correct for the installed hardware. The
Incompatible - compatible Active Safety Belt Control Modules are handed (connector
No sub type with the shell is different between LH and RH sides) and cannot be
information vehicle installed on another vehicle as they store VIN data. Using
the manufacturer approved diagnostic system run the
routine RID 0402h to clear self learnt data (except VIN).
Cycle the ignition and the module should re-learn the
correct configuration. clear the DTC and Refer to the
workshop manual section 501-20A and perform the Retract
and Release Self Test using the manufacturers approved
diagnostic system. Refer to the Warranty Policy and
Procedures manual if a module/component is suspect

U3000- Control Module Component Install a new control module, refer to the Warranty Policy
45 - Program internal and Procedures manual if a module/component is suspect.
memory failure memory After installing a new control module, updating software or
failure repairing a wiring harness perform an On Demand Self Test
and Retract and Release Self Test using the manufacturers
approved diagnostic system

U3000- Control Module Component Install a new control module, refer to the Warranty Policy
49 - Internal internal and Procedures manual if a module/component is suspect.
electronic electronic After installing a new control module, updating software or
failure failure repairing a wiring harness perform an On Demand Self Test
and Retract and Release Self Test using the manufacturers
approved diagnostic system

U3000- Control Module Belt retraction During 'aggressive' cornering or braking the belt mechanism
4B - Over motor has will operate to ensure the occupant is correctly positioned in
temperature exceeded the the seat. This DTC is set when the belt retraction motor has
design exceeded the temperature threshold and functionality is
operating inhibited until the motor has cooled. Allow the motor to
temperature cool and then clear the DTC. If the DTC resets refer to the
Warranty Policy and Procedures manual if a
module/component is suspect. After installing a new control
module, updating software or repairing a wiring harness
perform an On Demand Self Test and Retract and Release
Self Test using the manufacturers approved diagnostic
system

U3002- Vehicle Vehicle Using the manufacturer approved diagnostic system carry
81 Identification identification out the new module configuration routine
Number - number not
Invalid serial stored
data received New module
configuration
routine not
completed

U3003- Battery Voltage Power This DTC is set when the control module registers a
62 - Signal distribution difference of more than 2 volts between the CAN reference
compare failure fault to control battery voltage and the module supply voltage. Refer to the
module electrical circuit diagrams and check the power and ground
CAN network connections to the module. Using the manufacturer
fault approved diagnostic system, complete a CAN network
integrity test. Refer to the electrical circuit diagrams and
check the CAN network. After installing a new control
module, updating software or repairing a wiring harness
perform an On Demand Self Test and Retract and Release
Self Test using the manufacturers approved diagnostic
system

U3006- Control Module Vehicle This DTC is set when the measured supply voltage is below
16 Input Power battery 9 volts. Refer to the battery care manual and confirm
"A" - Circuit discharged vehicle battery is fully charged and serviceable. Refer to the
voltage below Power relevant section in the workshop manual and check the
threshold distribution charging system is performing correctly. Refer to the
fault to control electrical circuit diagrams and check the power and ground
module connections to the module. If no faults are found suspect the
causing volt control module, refer to the Warranty Policy and Procedures
drop on supply manual if a module/component is suspect
circuits
Internal
control
module fault

U3006- Control Module Vehicle This DTC is set when the measured supply voltage is above
17 Input Power charging 16 volts. Refer to the battery care manual and confirm
"A" - Circuit system fault vehicle battery is fully charged and serviceable. Refer to the
voltage above Internal relevant section in the workshop manual and check the
threshold control charging system is performing correctly. Refer to the
module fault electrical circuit diagrams and check the power and ground
connections to the module. If no faults are found suspect the
control module, refer to the Warranty Policy and Procedures
manual if a module/component is suspect

U0452- Invalid Data Supplementary Check the Restraints Control Module for related DTCs and
29 Received From Restraints refer to the relevant DTC index
Restraints System fault
Control Module Restraints
- Signal invalid Control
Module fault

U0452- Invalid Data Supplementary Check the Restraints Control Module for related DTCs and
31 Received From Restraints refer to the relevant DTC index
Restraints System fault
Control Module Restraints
- No signal Control
Module fault

U0415- Invalid Data Anti-Lock Check the Anti-Lock Braking System Control Module for
29 Received From Braking related DTCs and refer to the relevant DTC index
Anti-Lock System fault
Braking System Anti-Lock
(ABS) Control Braking
Module - Signal System control
invalid module fault

U0415- Invalid Data Anti-Lock Check the Anti-Lock Braking System Control Module for
31 Received From Braking related DTCs and refer to the relevant DTC index
Anti-Lock System fault
Braking System Anti-Lock
(ABS) Control Braking
Module - No System control
signal module fault

U0422- Invalid Data Central Check the Central Junction Box for related DTCs and refer
29 Received From Junction Box to the relevant DTC index
Body Control system fault
Module - Signal
invalid
U0422- Invalid Data Central Check the Central Junction Box for related DTCs and refer
31 Received From Junction Box to the relevant DTC index
Body Control system fault
Module - No
signal
U0423- Invalid Data Instrument Check the Instrument Panel Control Module for related
29 Received From Panel Control DTCs and refer to the relevant DTC index
Instrument Module
Panel Control system fault
Module - Signal
invalid
U0423- Invalid Data Instrument Check the Instrument Panel Control Module for related
31 Received From Panel Control DTCs and refer to the relevant DTC index
Instrument Module
Panel Control system fault
Module - No
signal
U0001- High Speed Power Refer to the electrical circuit diagrams and check the power
88 CAN distribution and ground connections to the module. Using the
Communication fault to control manufacturer approved diagnostic system, complete a CAN
Bus - Bus off module network integrity test. Refer to the electrical circuit
CAN network diagrams and check the CAN network. After installing a
fault new control module, updating software or repairing a wiring
harness perform an On Demand Self Test and Retract and
Release Self Test using the manufacturers approved
diagnostic system

U0104- Lost Power Refer to the electrical circuit diagrams and check the power
00 Communication distribution and ground connections to the module. Using the
With Cruise fault to control manufacturer approved diagnostic system, complete a CAN
Control Module module network integrity test. Refer to the electrical circuit
- No sub type CAN network diagrams and check the CAN network between the Active
information fault Safety Belt Module and Speed Control Module

U0405- Invalid Data Speed control Check the Speed Control Module for related DTCs and refer
29 Received From system related to the relevant DTC index
Cruise Control fault
Module - Signal
invalid
U0103- Lost Power Refer to the electrical circuit diagrams and check the power
00 Communication distribution and ground connections to the module. Using the
With Gear Shift fault to control manufacturer approved diagnostic system, complete a CAN
Control Module module network integrity test. Refer to the electrical circuit
A - No sub type CAN network diagrams and check the CAN network between the Active
information fault Safety Belt Module and Transmission Shift Control Module
Published: 17-Apr-2014

2012.0 XF (X250), 100-00

General Information

Diagnostic Trouble Code Index - DTC: Adaptive


Damping Module (SUMB) (G1426774)
DESCRIPTION AND OPERATION
Adaptive Damping Module (SUMB)
CAUTION:

Diagnosis by substitution from a donor vehicle is NOT acceptable. Substitution of control modules does not
guarantee confirmation of a fault, and may also cause additional faults in the vehicle being tested and/or the donor
vehicle

NOTES:

If the control module or a component is suspect and the vehicle remains under manufacturer warranty, refer to
the warranty policy and procedures manual, or determine if any prior approval programme is in operation,
prior to the installation of a new module/component

Generic scan tools may not read the codes listed, or may read only 5-digit codes. Match the 5 digits from the
scan tool to the first 5 digits of the 7-digit code listed to identify the fault (the last 2 digits give extra
information read by the manufacturer-approved diagnostic system)

When performing voltage or resistance tests, always use a digital multimeter accurate to three decimal places
and with a current calibration certificate. When testing resistance, always take the resistance of the digital
multimeter leads into account

Check and rectify basic faults before beginning diagnostic routines involving pinpoint tests

Inspect connectors for signs of water ingress, and pins for damage and/or corrosion

If diagnostic trouble codes are recorded and, after performing the pinpoint tests, a fault is not present, an
intermittent concern may be the cause. Always check for loose connections and corroded terminals

Where an 'on demand self-test' is referred to, this can be accessed via the 'diagnostic trouble code monitor' tab
on the manufacturers approved diagnostic system

Check DDW for open campaigns. Refer to the corresponding bulletins and SSMs which may be valid for the
specific customer complaint and carry out the recommendations as required

he table below lists all diagnostic trouble codes (DTCs) that could be logged in the adaptive damping module, for
additional diagnosis and testing information refer to the relevant diagnosis and testing sectionFor additional
information, refer to: Vehicle Dynamic Suspension (204-05 Vehicle Dynamic Suspension, Diagnosis and Testing).

DTC Description Possible Causes Action


C101D- Left Front Left Front Refer to the electrical circuit diagrams and check left front
12 vertical vertical vertical acceleration sensor circuit for short to power or
acceleration acceleration another circuit. Repair circuit, clear the DTC and retest the
sensor - Short sensor circuit system
to power short to power
C101D- Left Front Left Front Refer to the electrical circuit diagrams and check front
14 vertical vertical vertical acceleration sensor circuit for short to ground,
acceleration acceleration open circuit. If no fault found on wiring suspect sensor.
sensor - Short sensor circuit Replace sensor, clear DTC and retest the system
to ground, open short to ground,
circuit open circuit
Vertical
acceleration
sensor fault

C101D- Left Front Left front With vehicle parked on a level surface, read Left Front
22 vertical vertical Vertical Accelerometer voltage and check it lies in range
acceleration acceleration 1.9 to 2.1 volts. If not OK then check electrical wiring for
sensor - Signal sensor shorts, loose connections and repair as required. If wiring
amplitude > insecurely OK then suspect faulty sensor/incorrectly fitted sensor.
maximum mounted Check the sensor is correctly mounted, secure or replace
Left front sensor as required. Refer to the new module/component
vertical installation note at the top of the DTC Index, clear DTC
acceleration and retest system
sensor signal
circuit short to
another circuit
Left front
vertical
acceleration
sensor internal
fault

C101D- Left Front Left front Refer to the electrical circuit diagrams and check Left
26 vertical vertical Front Vertical Accelerometer signal circuit for faults, if
acceleration acceleration circuit is correct suspect faulty sensor, refer to the new
sensor - Signal sensor signal module/component installation note at the top of the DTC
rate of change circuit short to Index. Replace the sensor, clear the DTC and retest the
below threshold another circuit system
Left front
vertical
acceleration
sensor internal
fault

C101D- Left Front Left front Check Left Front Vertical Accelerometer for location and
78 vertical vertical security, if correct suspect faulty Accelerometer, refer to
acceleration acceleration the new module installation note at the top of the DTC
sensor - sensor bracket Index. Replace the sensor/bracket as required, clear the
Alignment or bent DTC and retest the system
adjustment Left front
incorrect vertical
acceleration
sensor damaged

C101E- Right Front Right Front Refer to the electrical circuit diagrams and check right
12 vertical vertical front vertical acceleration sensor circuit for short to power
acceleration acceleration or another circuit. Repair circuit, clear the DTC and retest
sensor - Short sensor circuit the system
to power short to power
C101E- Right Front Right Front Refer to the electrical circuit diagrams and check right
14 vertical vertical front vertical acceleration sensor circuit for short to
acceleration acceleration ground, open circuit. If no fault found on wiring suspect
sensor - Short sensor circuit sensor. Replace sensor, clear DTC and retest the system
to ground, open short to ground,
circuit open circuit
Vertical
acceleration
sensor fault

C101E- Right Front Right front With vehicle parked on a level surface, read Right Front
22 vertical vertical Vertical Accelerometer voltage and check it lies in range
acceleration acceleration 1.9 to 2.1 volts. If not OK then check electrical wiring for
sensor - Signal sensor shorts, loose connections and repair as required. If wiring
amplitude > insecurely OK then suspect faulty sensor/incorrectly fitted sensor.
maximum mounted Check the sensor is correctly mounted, secure or replace
Right front sensor as required. Refer to the new module/component
vertical installation note at the top of the DTC Index, clear DTC
acceleration and retest system
sensor signal
circuit short to
another circuit
Right front
vertical
acceleration
sensor internal
fault

C101E- Right Front Right front Refer to the electrical circuit diagrams and check Right
26 vertical vertical Front Vertical Accelerometer signal circuit for faults, if
acceleration acceleration circuit is correct suspect faulty sensor, refer to the new
sensor - Signal sensor signal module/component installation note at the top of the DTC
rate of change circuit short to Index. Replace the sensor, clear the DTC and retest the
below threshold another circuit system
Right front
vertical
acceleration
sensor internal
fault

C101E- Right Front Right front Check Right Front Vertical Accelerometer for location and
78 vertical vertical security, if correct suspect faulty Accelerometer, refer to
acceleration acceleration the new module installation note at the top of the DTC
sensor - sensor bracket Index. Replace the sensor/bracket as required, clear the
Alignment or bent DTC and retest the system
adjustment Right front
incorrect vertical
acceleration
sensor damaged

C1024- System Loss of power Refer to the electrical circuit diagrams and check power
00 Temporarily to control and ground circuits to Adaptive Damping Control Module
Disabled Due module whilst for intermittent or poor connection. Repair wiring circuits
To Power driving as required, clear DTC and retest the system
Interruption
During Driving
- No sub type
information
C1030- Left Rear Left Rear Refer to the electrical circuit diagrams and check left Rear
12 vertical vertical vertical acceleration sensor circuit for short to power or
acceleration acceleration another circuit. Repair circuit, clear the DTC and retest the
sensor - Short sensor circuit system
to power short to power

C1030- Left Rear Left rear Refer to the electrical circuit diagrams and check left Rear
14 vertical vertical vertical acceleration sensor circuit for short to ground,
acceleration acceleration open circuit. If no fault found on wiring suspect sensor.
sensor - Short sensor circuit Replace sensor, clear DTC and retest the system
to ground, open short to ground,
circuit open circuit
Vertical
acceleration
sensor fault

C1030- Left Rear Left Rear With vehicle parked on a level surface, read Left Rear
22 vertical vertical Vertical Accelerometer voltage and check it lies in range
acceleration acceleration 1.9 to 2.1 volts. If not OK then check electrical wiring for
sensor - Signal sensor shorts, loose connections and repair as required. If wiring
amplitude > insecurely OK then suspect faulty sensor/incorrectly fitted sensor.
maximum mounted Check the sensor is correctly mounted, secure or replace
Left Rear sensor as required. Refer to the new module/component
vertical installation note at the top of the DTC Index, clear DTC
acceleration and retest system
sensor signal
circuit short to
another circuit
Left Rear
vertical
acceleration
sensor internal
fault

C1030- Left Rear Left Rear Refer to the electrical circuit diagrams and check Left Rear
26 vertical vertical Vertical Accelerometer signal circuit for faults, if circuit is
acceleration acceleration correct suspect faulty sensor, refer to the new
sensor - Signal sensor signal module/component installation note at the top of the DTC
rate of change circuit short to Index. Replace the sensor, clear the DTC and retest the
below threshold another circuit system
Left Rear
vertical
acceleration
sensor internal
fault

C1030- Left Rear Left Rear Check Left Rear Vertical Accelerometer for location and
78 vertical vertical security, if correct suspect faulty Accelerometer, refer to
acceleration acceleration the new module installation note at the top of the DTC
sensor - sensor bracket Index. Replace the sensor/bracket as required, clear the
Alignment or bent DTC and retest the system
adjustment Left Rear
incorrect vertical
acceleration
sensor damaged

C1A03- Left Front Height sensor Refer to the electrical circuit diagrams and check Front
12 Height Sensor - circuit shorted Left Height Sensor circuit for short to power, If circuit
Circuit short to to another cable correct suspect Sensor internal fault, replace as required
power Height sensor
internal fault

C1A03- Left Front Wiring to Disconnect electrical connector to height sensor and
14 Height Sensor - sensor (signal) inspect connector pins & terminals for evidence of
Circuit short to open circuit corrosion or water ingress. If no corrosion found,
ground or open Wiring to disconnect harness at Control Module. A: Check for short
height sensor circuits between any of the 3 terminals and vehicle ground.
partial short to B: Check for electrical continuity between the two
ground connectors for each of the 3 terminals. Reconnect electrical
Wiring to connector at Control Module only. C: Check voltages at
height sensor terminals within height sensor connector (sensor not
short to other connected), with respect to vehicle body. • Voltage to
cable sensor ground connection should be ~0v • Voltage to
Height sensor sensor signal connection should be ~0v • Voltage to sensor
internal supply connection should be ~5v All voltages should be
electrical fault within ± 0.15v

C1A03- Left Front Height sensor Inspect for damage or loose fixings. NOTE If any height
21 Height Sensor - linkage not sensor fixings were slackened or found to be loose or if a
Signal connected height sensor was changed, the vehicle ride height MUST
amplitude < Height sensor be re-calibrated. Confirm that the correct height sensor part
minimum or bracket loose number is fitted, as specified in the service parts database.
Height sensor To check height sensor: Disconnect electrical connector to
bracket bent height sensor and inspect connecter pins & terminals for
Incorrect height evidence of corrosion or water ingress. If no corrosion
calibration found, disconnect harness at Control Module. A: Check for
Height sensor short circuits between any of the 3 terminals and vehicle
linkage toggled ground. B: Check for electrical continuity between the two
Height sensor connectors for each of the 3 terminals. Reconnect electrical
water ingress connector at Control Module only. C: Check voltages at
Wiring to terminals within height sensor connector (sensor not
height sensor connected), with respect to vehicle body. • Voltage to
partial short to sensor ground connection should be ~0v • Voltage to
ground sensor signal connection should be ~0v • Voltage to sensor
Wiring to supply connection should be ~5v All voltages should be
height sensor within ± 0.15v. To check sensor operation on the vehicle:
short to other Check for water ingress around the height sensors,
cable electrical connectors or shaft end. Check for excessive
Height sensor movement in the shaft in all directions. Raise vehicle
electrical fault (ideally on wheels-free ramp) until suspension on corner
Height sensor under investigation is at rebound to gain access to height
linkage bent sensor. Access may be improved by removing road wheel.
Incorrect height Carefully disconnect the height sensor link from the upper
sensor fitted suspension arm. Monitor the height sensor signal voltage
output for the height sensor under investigation. Position
the sensor arm so it is in the mid position and confirm that
the voltage is around 2.5 volts. Move the sensor arm over
the range ±40° around the mid position and confirm that
the voltage changes smoothly between around 0.2 volts
and 4.8 volts. If voltages are incorrect or do not change
smoothly then replace sensor. NOTE: For angles of
movement beyond ±40°, the sensor signal will clamp to a
voltage of ~0.15v or ~4.85v, depending on position of
sensor lever. This is normal. When investigation is
complete, refit height sensor link to upper arm. If any
fixings to the height sensor body or mounting bracket were
slackened or found to be loose or if a height sensor was
changed, the vehicle ride height MUST be re-calibrated.
Refer to the relevant section of the workshop manual for
the calibration procedure

C1A03- Left Front Height sensor Inspect for damage or loose fixings. NOTE If any height
22 Height Sensor - linkage not sensor fixings were slackened or found to be loose or if a
Signal connected height sensor was changed, the vehicle ride height MUST
amplitude > Height sensor be re-calibrated. Confirm that the correct height sensor part
maximum or bracket loose number is fitted, as specified in the service parts database.
Height sensor To check height sensor: Disconnect electrical connector to
bracket bent height sensor and inspect connecter pins & terminals for
Incorrect height evidence of corrosion or water ingress. If no corrosion
calibration found, disconnect harness at Control Module. A: Check for
Height sensor short circuits between any of the 3 terminals and vehicle
linkage toggled ground. B: Check for electrical continuity between the two
Height sensor connectors for each of the 3 terminals. Reconnect electrical
water ingress connector at Control Module only. C: Check voltages at
Wiring to terminals within height sensor connector (sensor not
height sensor connected), with respect to vehicle body. • Voltage to
partial short to sensor ground connection should be ~0v • Voltage to
ground sensor signal connection should be ~0v • Voltage to sensor
Wiring to supply connection should be ~5v All voltages should be
height sensor within ± 0.15v. To check sensor operation on the vehicle:
short to other Check for water ingress around the height sensors,
cable electrical connectors or shaft end. Check for excessive
Height sensor movement in the shaft in all directions. Raise vehicle
electrical fault (ideally on wheels-free ramp) until suspension on corner
Height sensor under investigation is at rebound to gain access to height
linkage bent sensor. Access may be improved by removing road wheel.
Incorrect height Carefully disconnect the height sensor link from the upper
sensor fitted suspension arm. Monitor the height sensor signal voltage
output for the height sensor under investigation. Position
the sensor arm so it is in the mid position and confirm that
the voltage is around 2.5 volts. Move the sensor arm over
the range ±40° around the mid position and confirm that
the voltage changes smoothly between around 0.2 volts
and 4.8 volts. If voltages are incorrect or do not change
smoothly then replace sensor. NOTE: For angles of
movement beyond ±40°, the sensor signal will clamp to a
voltage of ~0.15v or ~4.85v, depending on position of
sensor lever. This is normal. When investigation is
complete, refit height sensor link to upper arm. If any
fixings to the height sensor body or mounting bracket were
slackened or found to be loose or if a height sensor was
changed, the vehicle ride height MUST be re-calibrated.
Refer to the relevant section of the workshop manual for
the calibration procedure

C1A03- Left Front Incorrect height Refer to the workshop manual and perform the height
76 Height Sensor - calibration sensor calibration procedure. Clear the DTC and retest the
Wrong system
mounting
position
C1A03- Left Front Incorrect height Refer to the workshop manual and perform the height
78 Height Sensor - calibration sensor calibration procedure. Clear the DTC and retest the
Alignment or system
adjustment
incorrect
C1A04- Right Front Height sensor Refer to the electrical circuit diagrams and check Front
12 Height Sensor - circuit shorted Right Height Sensor circuit for short to power, If circuit
Circuit short to to another cable correct suspect Sensor internal fault, replace as required
power Height sensor
internal fault

C1A04- Right Front Wiring to Disconnect electrical connector to height sensor and
14 Height Sensor - sensor (signal) inspect connector pins & terminals for evidence of
Circuit short to open circuit corrosion or water ingress. If no corrosion found,
ground or open Wiring to disconnect harness at Control Module. A: Check for short
height sensor circuits between any of the 3 terminals and vehicle ground.
partial short to B: Check for electrical continuity between the two
ground connectors for each of the 3 terminals. Reconnect electrical
Wiring to connector at Control Module only. C: Check voltages at
height sensor terminals within height sensor connector (sensor not
short to other connected), with respect to vehicle body. • Voltage to
cable sensor ground connection should be ~0v • Voltage to
Height sensor sensor signal connection should be ~0v • Voltage to sensor
internal supply connection should be ~5v All voltages should be
electrical fault within ± 0.15v

C1A04- Right Front Height sensor Inspect for damage or loose fixings. NOTE If any height
21 Height Sensor - linkage not sensor fixings were slackened or found to be loose or if a
Signal connected height sensor was changed, the vehicle ride height MUST
amplitude < Height sensor be re-calibrated. Confirm that the correct height sensor part
minimum or bracket loose number is fitted, as specified in the service parts database.
Height sensor To check height sensor: Disconnect electrical connector to
bracket bent height sensor and inspect connecter pins & terminals for
Incorrect height evidence of corrosion or water ingress. If no corrosion
calibration found, disconnect harness at Control Module. A: Check for
Height sensor short circuits between any of the 3 terminals and vehicle
linkage toggled ground. B: Check for electrical continuity between the two
Height sensor connectors for each of the 3 terminals. Reconnect electrical
water ingress connector at Control Module only. C: Check voltages at
Wiring to terminals within height sensor connector (sensor not
height sensor connected), with respect to vehicle body. • Voltage to
partial short to sensor ground connection should be ~0v • Voltage to
ground sensor signal connection should be ~0v • Voltage to sensor
Wiring to supply connection should be ~5v All voltages should be
height sensor within ± 0.15v. To check sensor operation on the vehicle:
short to other Check for water ingress around the height sensors,
cable electrical connectors or shaft end. Check for excessive
Height sensor movement in the shaft in all directions. Raise vehicle
electrical fault (ideally on wheels-free ramp) until suspension on corner
Height sensor under investigation is at rebound to gain access to height
linkage bent sensor. Access may be improved by removing road wheel.
Incorrect height Carefully disconnect the height sensor link from the upper
sensor fitted suspension arm. Monitor the height sensor signal voltage
output for the height sensor under investigation. Position
the sensor arm so it is in the mid position and confirm that
the voltage is around 2.5 volts. Move the sensor arm over
the range ±40° around the mid position and confirm that
the voltage changes smoothly between around 0.2 volts
and 4.8 volts. If voltages are incorrect or do not change
smoothly then replace sensor. NOTE: For angles of
movement beyond ±40°, the sensor signal will clamp to a
voltage of ~0.15v or ~4.85v, depending on position of
sensor lever. This is normal. When investigation is
complete, refit height sensor link to upper arm. If any
fixings to the height sensor body or mounting bracket were
slackened or found to be loose or if a height sensor was
changed, the vehicle ride height MUST be re-calibrated.
Refer to the relevant section of the workshop manual for
the calibration procedure

C1A04- Right Front Height sensor Inspect for damage or loose fixings. NOTE If any height
22 Height Sensor - linkage not sensor fixings were slackened or found to be loose or if a
Signal connected height sensor was changed, the vehicle ride height MUST
amplitude > Height sensor be re-calibrated. Confirm that the correct height sensor part
maximum or bracket loose number is fitted, as specified in the service parts database.
Height sensor To check height sensor: Disconnect electrical connector to
bracket bent height sensor and inspect connecter pins & terminals for
Incorrect height evidence of corrosion or water ingress. If no corrosion
calibration found, disconnect harness at Control Module. A: Check for
Height sensor short circuits between any of the 3 terminals and vehicle
linkage toggled ground. B: Check for electrical continuity between the two
Height sensor connectors for each of the 3 terminals. Reconnect electrical
water ingress connector at Control Module only. C: Check voltages at
Wiring to terminals within height sensor connector (sensor not
height sensor connected), with respect to vehicle body. • Voltage to
partial short to sensor ground connection should be ~0v • Voltage to
ground sensor signal connection should be ~0v • Voltage to sensor
Wiring to supply connection should be ~5v All voltages should be
height sensor within ± 0.15v. To check sensor operation on the vehicle:
short to other Check for water ingress around the height sensors,
cable electrical connectors or shaft end. Check for excessive
Height sensor movement in the shaft in all directions. Raise vehicle
electrical fault (ideally on wheels-free ramp) until suspension on corner
Height sensor under investigation is at rebound to gain access to height
linkage bent sensor. Access may be improved by removing road wheel.
Incorrect height Carefully disconnect the height sensor link from the upper
sensor fitted suspension arm. Monitor the height sensor signal voltage
output for the height sensor under investigation. Position
the sensor arm so it is in the mid position and confirm that
the voltage is around 2.5 volts. Move the sensor arm over
the range ±40° around the mid position and confirm that
the voltage changes smoothly between around 0.2 volts
and 4.8 volts. If voltages are incorrect or do not change
smoothly then replace sensor. NOTE: For angles of
movement beyond ±40°, the sensor signal will clamp to a
voltage of ~0.15v or ~4.85v, depending on position of
sensor lever. This is normal. When investigation is
complete, refit height sensor link to upper arm. If any
fixings to the height sensor body or mounting bracket were
slackened or found to be loose or if a height sensor was
changed, the vehicle ride height MUST be re-calibrated.
Refer to the relevant section of the workshop manual for
the calibration procedure

C1A04- Right Front Incorrect height Refer to the workshop manual and perform the height
76 Height Sensor - calibration sensor calibration procedure. Clear the DTC and retest the
Wrong system
mounting
position
C1A04- Right Front Incorrect height Refer to the workshop manual and perform the height
78 Height Sensor - calibration sensor calibration procedure. Clear the DTC and retest the
Alignment or system
adjustment
incorrect
C1A05- Left Rear Height sensor Refer to the electrical circuit diagrams and check Rear Left
12 Height Sensor - circuit shorted Height Sensor circuit for short to power, If circuit correct
Circuit short to to another cable suspect Sensor internal fault, replace as required
power Height sensor
internal fault

C1A05- Left Rear Wiring to Disconnect electrical connector to height sensor and
14 Height Sensor - sensor (signal) inspect connector pins & terminals for evidence of
Circuit short to open circuit corrosion or water ingress. If no corrosion found,
ground or open Wiring to disconnect harness at Control Module. A: Check for short
height sensor circuits between any of the 3 terminals and vehicle ground.
partial short to B: Check for electrical continuity between the two
ground connectors for each of the 3 terminals. Reconnect electrical
Wiring to connector at Control Module only. C: Check voltages at
height sensor terminals within height sensor connector (sensor not
short to other connected), with respect to vehicle body. • Voltage to
cable sensor ground connection should be ~0v • Voltage to
Height sensor sensor signal connection should be ~0v • Voltage to sensor
internal supply connection should be ~5v All voltages should be
electrical fault within ± 0.15v

C1A05- Left Rear Height sensor Inspect for damage or loose fixings. NOTE If any height
21 Height Sensor - linkage not sensor fixings were slackened or found to be loose or if a
Signal connected height sensor was changed, the vehicle ride height MUST
amplitude < Height sensor be re-calibrated. Confirm that the correct height sensor part
minimum or bracket loose number is fitted, as specified in the service parts database.
Height sensor To check height sensor: Disconnect electrical connector to
bracket bent height sensor and inspect connecter pins & terminals for
Incorrect height evidence of corrosion or water ingress. If no corrosion
calibration found, disconnect harness at Control Module. A: Check for
Height sensor short circuits between any of the 3 terminals and vehicle
linkage toggled ground. B: Check for electrical continuity between the two
Height sensor connectors for each of the 3 terminals. Reconnect electrical
water ingress connector at Control Module only. C: Check voltages at
Wiring to terminals within height sensor connector (sensor not
height sensor connected), with respect to vehicle body. • Voltage to
partial short to sensor ground connection should be ~0v • Voltage to
ground sensor signal connection should be ~0v • Voltage to sensor
Wiring to supply connection should be ~5v All voltages should be
height sensor within ± 0.15v. To check sensor operation on the vehicle:
short to other Check for water ingress around the height sensors,
cable electrical connectors or shaft end. Check for excessive
Height sensor movement in the shaft in all directions. Raise vehicle
electrical fault (ideally on wheels-free ramp) until suspension on corner
Height sensor under investigation is at rebound to gain access to height
linkage bent sensor. Access may be improved by removing road wheel.
Incorrect height Carefully disconnect the height sensor link from the upper
sensor fitted suspension arm. Monitor the height sensor signal voltage
output for the height sensor under investigation. Position
the sensor arm so it is in the mid position and confirm that
the voltage is around 2.5 volts. Move the sensor arm over
the range ±40° around the mid position and confirm that
the voltage changes smoothly between around 0.2 volts
and 4.8 volts. If voltages are incorrect or do not change
smoothly then replace sensor. NOTE: For angles of
movement beyond ±40°, the sensor signal will clamp to a
voltage of ~0.15v or ~4.85v, depending on position of
sensor lever. This is normal. When investigation is
complete, refit height sensor link to upper arm. If any
fixings to the height sensor body or mounting bracket were
slackened or found to be loose or if a height sensor was
changed, the vehicle ride height MUST be re-calibrated.
Refer to the relevant section of the workshop manual for
the calibration procedure

C1A05- Left Rear Height sensor Inspect for damage or loose fixings. NOTE If any height
22 Height Sensor - linkage not sensor fixings were slackened or found to be loose or if a
Signal connected height sensor was changed, the vehicle ride height MUST
amplitude > Height sensor be re-calibrated. Confirm that the correct height sensor part
maximum or bracket loose number is fitted, as specified in the service parts database.
Height sensor To check height sensor: Disconnect electrical connector to
bracket bent height sensor and inspect connecter pins & terminals for
Incorrect height evidence of corrosion or water ingress. If no corrosion
calibration found, disconnect harness at Control Module. A: Check for
Height sensor short circuits between any of the 3 terminals and vehicle
linkage toggled ground. B: Check for electrical continuity between the two
Height sensor connectors for each of the 3 terminals. Reconnect electrical
water ingress connector at Control Module only. C: Check voltages at
Wiring to terminals within height sensor connector (sensor not
height sensor connected), with respect to vehicle body. • Voltage to
partial short to sensor ground connection should be ~0v • Voltage to
ground sensor signal connection should be ~0v • Voltage to sensor
Wiring to supply connection should be ~5v All voltages should be
height sensor within ± 0.15v. To check sensor operation on the vehicle:
short to other Check for water ingress around the height sensors,
cable electrical connectors or shaft end. Check for excessive
Height sensor movement in the shaft in all directions. Raise vehicle
electrical fault (ideally on wheels-free ramp) until suspension on corner
Height sensor under investigation is at rebound to gain access to height
linkage bent sensor. Access may be improved by removing road wheel.
Incorrect height Carefully disconnect the height sensor link from the upper
sensor fitted suspension arm. Monitor the height sensor signal voltage
output for the height sensor under investigation. Position
the sensor arm so it is in the mid position and confirm that
the voltage is around 2.5 volts. Move the sensor arm over
the range ±40° around the mid position and confirm that
the voltage changes smoothly between around 0.2 volts
and 4.8 volts. If voltages are incorrect or do not change
smoothly then replace sensor. NOTE: For angles of
movement beyond ±40°, the sensor signal will clamp to a
voltage of ~0.15v or ~4.85v, depending on position of
sensor lever. This is normal. When investigation is
complete, refit height sensor link to upper arm. If any
fixings to the height sensor body or mounting bracket were
slackened or found to be loose or if a height sensor was
changed, the vehicle ride height MUST be re-calibrated.
Refer to the relevant section of the workshop manual for
the calibration procedure

C1A05- Left Rear Incorrect height Refer to the workshop manual and perform the height
76 Height Sensor - calibration sensor calibration procedure. Clear the DTC and retest the
Wrong system
mounting
position
C1A05- Left Rear Incorrect height Refer to the workshop manual and perform the height
78 Height Sensor - calibration sensor calibration procedure. Clear the DTC and retest the
Alignment or system
adjustment
incorrect
C1A06- Right Rear Height sensor Refer to the electrical circuit diagrams and check Rear
12 Height Sensor - circuit shorted Right Height Sensor circuit for short to power, If circuit
Circuit short to to another cable correct suspect Sensor internal fault, replace as required
power Height sensor
internal fault

C1A06- Right Rear Wiring to Disconnect electrical connector to height sensor and
14 Height Sensor - sensor (signal) inspect connector pins & terminals for evidence of
Circuit short to open circuit corrosion or water ingress. If no corrosion found,
ground or open Wiring to disconnect harness at Control Module. A: Check for short
height sensor circuits between any of the 3 terminals and vehicle ground.
partial short to B: Check for electrical continuity between the two
ground connectors for each of the 3 terminals. Reconnect electrical
Wiring to connector at Control Module only. C: Check voltages at
height sensor terminals within height sensor connector (sensor not
short to other connected), with respect to vehicle body. • Voltage to
cable sensor ground connection should be ~0v • Voltage to
Height sensor sensor signal connection should be ~0v • Voltage to sensor
internal supply connection should be ~5v All voltages should be
electrical fault within ± 0.15v

C1A06- Right Rear Height sensor Inspect for damage or loose fixings. NOTE If any height
21 Height Sensor - linkage not sensor fixings were slackened or found to be loose or if a
Signal connected height sensor was changed, the vehicle ride height MUST
amplitude < Height sensor be re-calibrated. Confirm that the correct height sensor part
minimum or bracket loose number is fitted, as specified in the service parts database.
Height sensor To check height sensor: Disconnect electrical connector to
bracket bent height sensor and inspect connecter pins & terminals for
Incorrect height evidence of corrosion or water ingress. If no corrosion
calibration found, disconnect harness at Control Module. A: Check for
Height sensor short circuits between any of the 3 terminals and vehicle
linkage toggled ground. B: Check for electrical continuity between the two
Height sensor connectors for each of the 3 terminals. Reconnect electrical
water ingress connector at Control Module only. C: Check voltages at
Wiring to terminals within height sensor connector (sensor not
height sensor connected), with respect to vehicle body. • Voltage to
partial short to sensor ground connection should be ~0v • Voltage to
ground sensor signal connection should be ~0v • Voltage to sensor
Wiring to supply connection should be ~5v All voltages should be
height sensor within ± 0.15v. To check sensor operation on the vehicle:
short to other Check for water ingress around the height sensors,
cable electrical connectors or shaft end. Check for excessive
Height sensor movement in the shaft in all directions. Raise vehicle
electrical fault (ideally on wheels-free ramp) until suspension on corner
Height sensor under investigation is at rebound to gain access to height
linkage bent sensor. Access may be improved by removing road wheel.
Incorrect height Carefully disconnect the height sensor link from the upper
sensor fitted suspension arm. Monitor the height sensor signal voltage
output for the height sensor under investigation. Position
the sensor arm so it is in the mid position and confirm that
the voltage is around 2.5 volts. Move the sensor arm over
the range ±40° around the mid position and confirm that
the voltage changes smoothly between around 0.2 volts
and 4.8 volts. If voltages are incorrect or do not change
smoothly then replace sensor. NOTE: For angles of
movement beyond ±40°, the sensor signal will clamp to a
voltage of ~0.15v or ~4.85v, depending on position of
sensor lever. This is normal. When investigation is
complete, refit height sensor link to upper arm. If any
fixings to the height sensor body or mounting bracket were
slackened or found to be loose or if a height sensor was
changed, the vehicle ride height MUST be re-calibrated.
Refer to the relevant section of the workshop manual for
the calibration procedure

C1A06- Right Rear Height sensor Inspect for damage or loose fixings. NOTE If any height
22 Height Sensor - linkage not sensor fixings were slackened or found to be loose or if a
Signal connected height sensor was changed, the vehicle ride height MUST
amplitude > Height sensor be re-calibrated. Confirm that the correct height sensor part
maximum or bracket loose number is fitted, as specified in the service parts database.
Height sensor To check height sensor: Disconnect electrical connector to
bracket bent height sensor and inspect connecter pins & terminals for
Incorrect height evidence of corrosion or water ingress. If no corrosion
calibration found, disconnect harness at Control Module. A: Check for
Height sensor short circuits between any of the 3 terminals and vehicle
linkage toggled ground. B: Check for electrical continuity between the two
Height sensor connectors for each of the 3 terminals. Reconnect electrical
water ingress connector at Control Module only. C: Check voltages at
Wiring to terminals within height sensor connector (sensor not
height sensor connected), with respect to vehicle body. • Voltage to
partial short to sensor ground connection should be ~0v • Voltage to
ground sensor signal connection should be ~0v • Voltage to sensor
Wiring to supply connection should be ~5v All voltages should be
height sensor within ± 0.15v. To check sensor operation on the vehicle:
short to other Check for water ingress around the height sensors,
cable electrical connectors or shaft end. Check for excessive
Height sensor movement in the shaft in all directions. Raise vehicle
electrical fault (ideally on wheels-free ramp) until suspension on corner
Height sensor under investigation is at rebound to gain access to height
linkage bent sensor. Access may be improved by removing road wheel.
Incorrect height Carefully disconnect the height sensor link from the upper
sensor fitted suspension arm. Monitor the height sensor signal voltage
output for the height sensor under investigation. Position
the sensor arm so it is in the mid position and confirm that
the voltage is around 2.5 volts. Move the sensor arm over
the range ±40° around the mid position and confirm that
the voltage changes smoothly between around 0.2 volts
and 4.8 volts. If voltages are incorrect or do not change
smoothly then replace sensor. NOTE: For angles of
movement beyond ±40°, the sensor signal will clamp to a
voltage of ~0.15v or ~4.85v, depending on position of
sensor lever. This is normal. When investigation is
complete, refit height sensor link to upper arm. If any
fixings to the height sensor body or mounting bracket were
slackened or found to be loose or if a height sensor was
changed, the vehicle ride height MUST be re-calibrated.
Refer to the relevant section of the workshop manual for
the calibration procedure

C1A06- Right Rear Incorrect height Refer to the workshop manual and perform the height
76 Height Sensor - calibration sensor calibration procedure. Clear the DTC and retest the
Wrong system
mounting
position
C1A06- Right Rear Incorrect height Refer to the workshop manual and perform the height
78 Height Sensor - calibration sensor calibration procedure. Clear the DTC and retest the
Alignment or system
adjustment
incorrect
C110C- Left Front Left front Refer to the electrical circuit diagrams and check Front
01 Damper damper Left damper solenoid circuit for faults, If no faults are
Solenoid - solenoid circuit evident suspect a faulty control module, refer to the new
General fault module installation note at the top of the DTC Index
electrical
failure
C110C- Left Front Front Left Refer to the electrical circuit diagrams and check Front
18 Damper Damper Left Damper Solenoid circuit resistance. Damper solenoid
Solenoid - Actuator open circuit should lie in range of 2 to 3.5 ohms
Circuit current circuit at startup
below threshold
C110C- Left Front Front Left Refer to the electrical circuit diagrams and check Front
19 Damper Damper Left Damper Solenoid circuit resistance. Damper solenoid
Solenoid - Solenoid circuit circuit should lie in range of 2 to 3.5 ohms
Circuit current current above
above threshold threshold

C110C- Left Front Left front Carry out any pinpoint tests associated with this DTC
14 Damper damper using the manufacturer approved diagnostic system. Refer
Solenoid - solenoid circuit to the electrical circuit diagrams and check left front
Short to - short to damper solenoid circuit for short to ground, open circuit.
ground, open ground, open Check and install a new damper as required. Refer to the
circuit circuit warranty policy and procedures manual if a
Left front module/component is suspect
damper failure

C110C- Left Front Left front Carry out any pinpoint tests associated with this DTC
1D Damper damper using the manufacturer approved diagnostic system. Refer
Solenoid - solenoid circuit to the electrical circuit diagrams and check left front
Circuit current - short to damper solenoid circuit for short to ground, power, open
out of range ground/power, circuit. Check and install a new damper as required. Refer
open circuit to the warranty policy and procedures manual if a
Left front module/component is suspect
damper failure

C110C- Left Front Front Left Refer to the electrical circuit diagrams and check Front
64 Damper Damper Left Damper Solenoid circuit resistance. Damper solenoid
Solenoid - Solenoid circuit should lie in range of 2 to 3.5 ohms
Signal Measured
plausibility Current control
failure loop failed
Front Left
Damper
Solenoid open
circuit

C110D- Right Front Right front Refer to the electrical circuit diagrams and check Front
01 Damper damper Right damper solenoid circuit for faults, If no faults are
Solenoid - solenoid circuit evident suspect a faulty control module, refer to the new
General fault module installation note at the top of the DTC Index
electrical
failure
C110D- Right Front Front Right Refer to the electrical circuit diagrams and check Front
18 Damper Damper Right Damper Solenoid circuit resistance. Damper
Solenoid - Actuator open solenoid circuit should lie in range of 2 to 3.5 ohms
Circuit current circuit at startup
below threshold
C110D- Right Front Front Right Refer to the electrical circuit diagrams and check Front
19 Damper Damper Right Damper Solenoid circuit resistance. Damper
Solenoid - Solenoid circuit solenoid circuit should lie in range of 2 to 3.5 ohms
Circuit current current above
above threshold threshold

C110D- Right Front Right front Carry out any pinpoint tests associated with this DTC
14 Damper damper using the manufacturer approved diagnostic system. Refer
Solenoid - solenoid circuit to the electrical circuit diagrams and check Right front
Short to - short to damper solenoid circuit for short to ground, open circuit.
ground, open ground, open Check and install a new damper as required. Refer to the
circuit circuit warranty policy and procedures manual if a
Right front module/component is suspect
damper failure

C110D- Right Front Right front Carry out any pinpoint tests associated with this DTC
1D Damper damper using the manufacturer approved diagnostic system. Refer
Solenoid - solenoid circuit to the electrical circuit diagrams and check Right front
Circuit current - short to damper solenoid circuit for short to ground, power, open
out of range ground/power, circuit. Check and install a new damper as required. Refer
open circuit to the warranty policy and procedures manual if a
Right front module/component is suspect
damper failure

C110D- Right Front Front Right Refer to the electrical circuit diagrams and check Front
64 Damper Damper Right Damper Solenoid circuit resistance. Damper
Solenoid - Solenoid solenoid circuit should lie in range of 2 to 3.5 ohms
Signal Measured
plausibility Current control
failure loop failed
Front Right
Damper
Solenoid open
circuit

C110E- Left Rear Left Rear Refer to the electrical circuit diagrams and check Rear Left
01 Damper damper damper solenoid circuit for faults, If no faults are evident
Solenoid - solenoid circuit suspect a faulty control module, refer to the new module
General fault installation note at the top of the DTC Index
electrical
failure
C110E- Left Rear Rear Left Refer to the electrical circuit diagrams and check Rear Left
18 Damper Damper Damper Solenoid circuit resistance. Damper solenoid
Solenoid - Actuator open circuit should lie in range of 2 to 3.5 ohms
Circuit current circuit at startup
below threshold
C110E- Left Rear Rear Left Refer to the electrical circuit diagrams and check Rear Left
19 Damper Damper Damper Solenoid circuit resistance. Damper solenoid
Solenoid - Solenoid circuit circuit should lie in range of 2 to 3.5 ohms
Circuit current current above
above threshold threshold

C110E- Left Rear Left Rear Carry out any pinpoint tests associated with this DTC
14 Damper damper using the manufacturer approved diagnostic system. Refer
Solenoid - solenoid circuit to the electrical circuit diagrams and check left Rear
Short to - short to damper solenoid circuit for short to ground, open circuit.
ground, open ground, open Check and install a new damper as required. Refer to the
circuit circuit warranty policy and procedures manual if a
Left Rear module/component is suspect
damper failure

C110E- Left Rear Left Rear Carry out any pinpoint tests associated with this DTC
1D Damper damper using the manufacturer approved diagnostic system. Refer
Solenoid - solenoid circuit to the electrical circuit diagrams and check left Rear
Circuit current - short to damper solenoid circuit for short to ground, power, open
out of range ground/power, circuit. Check and install a new damper as required. Refer
open circuit to the warranty policy and procedures manual if a
Left Rear module/component is suspect
damper failure

C110E- Left Rear Rear Left Refer to the electrical circuit diagrams and check Rear Left
64 Damper Damper Damper Solenoid circuit resistance. Damper solenoid
Solenoid - Solenoid circuit should lie in range of 2 to 3.5 ohms
Signal Measured
plausibility Current control
failure loop failed
Rear Left
Damper
Solenoid open
circuit

C110F- Right Rear Right Rear Refer to the electrical circuit diagrams and check Rear
01 Damper damper Right damper solenoid circuit for faults, If no faults are
Solenoid - solenoid circuit evident suspect a faulty control module, refer to the new
General fault module installation note at the top of the DTC Index
Electrical
Failure
C110F- Right Rear Rear Right Refer to the electrical circuit diagrams and check Rear
18 Damper Damper Right Damper Solenoid circuit resistance. Damper
Solenoid - Actuator open solenoid circuit should lie in range of 2 to 3.5 ohms
Circuit current circuit at startup
below threshold
C110F- Right Rear Rear Right Refer to the electrical circuit diagrams and check Rear
19 Damper Damper Right Damper Solenoid circuit resistance. Damper
Solenoid - Solenoid circuit solenoid circuit should lie in range of 2 to 3.5 ohms
Circuit current current above
above threshold threshold

C110F- Right Rear Right Rear Carry out any pinpoint tests associated with this DTC
14 Damper damper using the manufacturer approved diagnostic system. Refer
Solenoid - solenoid circuit to the electrical circuit diagrams and check Right Rear
Short to - short to damper solenoid circuit for short to ground, open circuit.
ground, open ground, open Check and install a new damper as required. Refer to the
circuit circuit warranty policy and procedures manual if a
Right Rear module/component is suspect
damper failure

C110F- Right Rear Right Rear Carry out any pinpoint tests associated with this DTC
1D Damper damper using the manufacturer approved diagnostic system. Refer
Solenoid - solenoid circuit to the electrical circuit diagrams and check Right Rear
Circuit current - short to damper solenoid circuit for short to ground, power, open
out of range ground/power, circuit. Check and install a new damper as required. Refer
open circuit to the warranty policy and procedures manual if a
Right Rear module/component is suspect
damper failure

C110F- Right Rear Rear Right Refer to the electrical circuit diagrams and check Rear
64 Damper Damper Right Damper Solenoid circuit resistance. Damper
Solenoid - Solenoid solenoid circuit should lie in range of 2 to 3.5 ohms
Signal Measured
plausibility Current control
failure loop failed
Rear Right
Damper
Solenoid open
circuit

C1B14- Sensor Supply Left Front Refer to the electrical circuit diagrams and check sensor
1C Voltage A - Out Height Sensor supply for circuit fault. Check all height sensors. Check
of range or Right Front module sensor supply output voltage measured voltage
Height Sensor should be between 4.995 volts and 4.85 volts
or Left Rear
Height Sensor
or Right Rear
Height Sensor
supply partial
short to other
circuit or
ground
Left Front
Height Sensor
or Right Front
Height Sensor
or Left Rear
Height Sensor
or Right Rear
Height Sensor
internal failure
Internal control
module failure

C1B15- Sensor Supply Left Front Refer to the electrical circuit diagrams and check sensor
1C Voltage B - Out Vertical supply for circuit fault. Check all Vertical Acceleration
of range Acceleration Sensors. Check control module sensor supply output
Sensor or Right voltage Measured voltage should be between 4.995 volts
Front Vertical and 4.85 volts
Acceleration
Sensor or Left
Rear Vertical
Acceleration
Sensor or Right
Rear Vertical
Acceleration
Sensor supply
partial short to
other circuit or
ground. Left
Front Vertical
Acceleration
Sensor or Right
Front Vertical
Acceleration
Sensor or Left
Rear Vertical
Acceleration
Sensor or Right
Rear Vertical
Acceleration
Sensor supply
partial short to
other circuit or
ground
Left Front
Vertical
Acceleration
Sensor or Right
Front Vertical
Acceleration
Sensor or Left
Rear Vertical
Acceleration
Sensor or Right
Rear Vertical
Acceleration
Sensor internal
failure
Internal control
module failure
U0001- High speed Lost Check Engine Control Module for stored DTCs. Refer to
88 CAN Communication the electrical circuit diagrams and check CAN Bus circuit
communication With Engine for faults, check CAN circuits for open circuits or shorts to
bus - Bus off Control Module power, ground or other circuits
(ECM) (CAN
Bus circuit
fault)

U0100- Lost Missing Check Engine Control Module for stored DTCs. Refer to
00 Communication message from the electrical circuit diagrams and check CAN Bus for
With ECM circuit fault
ECM/PCM A -
No sub type
information
U0101- Lost Lost Check Transmission Control Module for stored DTCs.
00 Communication Communication Refer to the electrical circuit diagrams and check CAN Bus
with TCM - No with for circuit fault
sub type Transmission
information control module
(TCM) (CAN
Bus circuit
fault)

U0103- Lost Lost Check Gear Shift Module for stored DTCs. Refer to the
00 Communication Communication electrical circuit diagrams and check Can Bus for circuit
With Gear Shift With Gear Shift faults
Control Module Module (GSM)
A - No sub type (CAN Bus
information circuit fault)

U0121- Lost Lost Check Anti lock Brake System Control Module for stored
00 Communication Communication DTCs. Refer to the electrical circuit diagrams and check
With Anti-Lock With Anti-Lock Can Bus circuit to Anti lock Brake System Control Module
Brake System Brake System for circuit faults
(ABS) Control (ABS) Control
Module - No Module (CAN
sub type Bus circuit
information fault)

U0132- Lost Lost Check Air Suspension Control Module for stored DTCs.
00 Communication Communication Refer to the electrical circuit diagrams and check CAN Bus
With With Air circuit to Air Suspension Control Module for circuit faults
Suspension Suspension
Control Module Control Module
A - No sub type (CAN Bus
information circuit fault

U0136- Lost Lost Check Rear Differential Control Module for stored DTCs.
00 Communication Communication Refer to the electrical circuit diagrams and check Can Bus
With With Rear circuit to Rear Differential Control Module for circuit
Differential Differential faults
Control Module Control Module
- Rear - No sub (CAN Bus
type circuit fault)
information
U0140- Lost Lost Check Body Control Module for stored DTCs. Refer to the
00 Communication Communication electrical circuit diagrams and check CAN Bus circuit to
With Body With Body Body Control Module for faults
Control Module Control Module
- No sub type (Front Smart
information Junction Box)
(CAN Bus
circuit fault)

U0142- Lost Lost Check Rear Smart Junction Box for stored DTCs. Refer to
00 Communication Communication the electrical circuit diagrams and check Can Bus circuit to
With Body with rear smart Rear Smart Junction Box for faults
Control Module junction box
B - No sub type (CAN Bus
information circuit fault)

U0155- Lost Lost Check Instrument Panel Cluster for stored DTCs. Refer to
00 Communication Communication the electrical circuit diagrams and check CAN Bus to
With With Instrument Panel Cluster for circuit fault
Instrument Instrument
Panel Cluster Panel Cluster
(IPC) Control (IPC) Control
Module - No Module (CAN
sub type bus circuit
information fault)

U0300- Internal control CAN master Check Front Smart Junction Box vehicle configuration file,
00 module configuration check part number of adaptive damping control module
software ID incorrect
incompatibility
- No sub type
information
U0401- Invalid Data Invalid Data Check Engine Control Module for DTCs. Refer to the
68 Received from Received from relevant DTC index
ECM/PCM A - Engine Control
Event Module
information
U0402- Invalid Data Invalid Data Check for Transmission Control Module DTCs. Refer to
68 Received from Received from relevant DTC index
TCM - Event Transmission
information control module

U0404- Invalid Data Invalid data Check Gear Shift Control Module for DTCs. Refer to the
68 Received from received from relevant DTC index
Gear Shift gear shift
Control Module control module
A - Event
information
U0415- Invalid Data Invalid Data Check for Anti lock Brake System DTCs. Refer to the
68 Received From Received From relevant DTC index
Anti-Lock Anti-Lock
Brake System Brake System
(ABS) Control (ABS) Control
Module - Event Module
information
U0421- Invalid Data Invalid Data Check Air Suspension Control Module for stored DTCs.
68 Received from Received From Refer to the relevant DTC index
Suspension Air Suspension
Control Module Control Module
A - Event
information
U0422- Invalid Data Invalid Data Check Body Control Module (Front Smart Junction Box)
68 Received From Received From for stored DTCs. Refer to the relevant DTC index
Body Control Body Control
Module - Event Module (Front
information Smart Junction
Box)

U0437- Invalid Data Invalid Data Check Rear Differential Control Module for stored DTCs.
68 Received From Received From Refer to the relevant DTC index
Differential Rear
Control Module Differential
- Rear - Event Control Module
information
U0443- Invalid Data Invalid Data Check rear smart junction box for DTCs and refer to
68 Received From Received From relevant DTC index
Body Control body control
Module B - module B (Rear
Event Smart Junction
information Box)

U1A14- CAN CAN network Refer to circuit diagrams and check CAN Bus circuit for
00 initialization harness short, fault (short to power, ground or open circuit)
failure - No sub disconnected
type
information
U2100- Initial Car Install car config to Front Smart Junction Box. Clear DTC
00 Configuration Configuration and retest systems
Not Complete - Data not loaded
No sub type (New Body
information Control Module
(Front Smart
Junction Box)
fitted to vehicle
and not
initialized)
Internal Body
Control Module
(Front Smart
Junction Box)
failure

U2101- Control Module Car Carry out the new module software installation procedure
00 Configuration Configuration
Incompatible - Data
No sub type transmitted
information over CAN does
not match
adaptive
damping
control module
internal config

U3000- Control module General Check integrity of electrical connectors and pins to
01 - General electrical module. Check damper negative circuits for short to
Electrical failure Ground. Refer to the new module installation note at the
Failure top of the DTC Index. Install a new Adaptive Damping
Control Module

U3000- Control Module Module Internal Refer to the electrical wiring diagrams and check all
04 - System failure damper solenoid circuits for short to power. If no harness
Internal Failure faults are found suspect adaptive damping control module.
Install a new module, refer to new module installation note
at top of DTC Index

U3000- Control Module Module Internal Suspect Adaptive Damping Control Module internal
43 - Special failure failure. Install a new module, refer to the new
memory failure module/component installation note at the top of the DTC
Index

U3000- Control Module Module Internal Refer to the electrical circuit diagrams and check power
45 - Program failure and ground circuit for fault. Clear DTC turn off ignition,
memory failure wait 1 minute. Turn on ignition, check for DTCs. If DTC
returns suspect Adaptive Damping Control Module
internal failure. Install a new module, refer to the new
module/component installation note at the top of the DTC
Index

U3000- Control Module Module Internal If this DTC is logged contact your local in-market support
47 - Watchdog / Failure
safety Micro
controller
failure
U3000- Control Module Adaptive Install the latest software / Carry out the new-module
52 - Not activated Damping (software) install procedure
Control Module
has been
replaced and
not
programmed

U3000- Control Module Adaptive Install the latest software / Carry out the new-module
54 - Missing damping (software) install procedure
calibration control module
has been
replaced and no
software is
installed

U3003- Battery voltage Circuit voltage Check the battery is in good condition and fully charged,
1C - Circuit out of range refer to the battery care manual. Refer to the starting and
voltage out of (Supply charging section of the workshop manual and check the
range Voltage at performance of the charging system. Refer to the electrical
adaptive circuit diagrams and check power and ground circuit to
damping adaptive damping control module for faults, including
control module intermittent high resistance
< 10.5v or
Supply Voltage
at adaptive
damping
control module
> 18v for 30s)

U3003- Battery Voltage High Check the battery is in good condition and fully charged,
62 - Signal Resistance refer to the battery care manual. Refer to the starting and
compare failure Connections charging section of the workshop manual and check the
Adaptive performance of the charging system. Refer to the electrical
Damping circuit diagrams and check power and ground circuit to
Control module adaptive damping control module for faults, including
Internal Failure intermittent high resistance
Published: 17-Apr-2014

2012.0 XF (X250), 100-00

General Information

Diagnostic Trouble Code Index - DTC: Anti-Lock


Braking System (ABS) (G1426775)
DESCRIPTION AND OPERATION
Anti-Lock Braking System (ABS)
CAUTION:

Diagnosis by substitution from a donor vehicle is NOT acceptable. Substitution of control modules does not
guarantee confirmation of a fault, and may also cause additional faults in the vehicle being tested and/or the donor
vehicle

NOTES:

If the control module or a component is suspect and the vehicle remains under manufacturer warranty, refer to
the warranty policy and procedures manual, or determine if any prior approval programme is in operation,
prior to the installation of a new module/component

Generic scan tools may not read the codes listed, or may read only 5-digit codes. Match the 5 digits from the
scan tool to the first 5 digits of the 7-digit code listed to identify the fault (the last 2 digits give extra
information read by the manufacturer-approved diagnostic system)

When performing voltage or resistance tests, always use a digital multimeter accurate to three decimal places
and with a current calibration certificate. When testing resistance, always take the resistance of the digital
multimeter leads into account

Check and rectify basic faults before beginning diagnostic routines involving pinpoint tests

Inspect connectors for signs of water ingress, and pins for damage and/or corrosion

If diagnostic trouble codes are recorded and, after performing the pinpoint tests, a fault is not present, an
intermittent concern may be the cause. Always check for loose connections and corroded terminals

Where an 'on demand self-test' is referred to, this can be accessed via the 'diagnostic trouble code monitor' tab
on the manufacturers approved diagnostic system

Check DDW for open campaigns. Refer to the corresponding bulletins and SSMs which may be valid for the
specific customer complaint and carry out the recommendations as required

The table below lists all Diagnostic Trouble Codes (DTCs) that could be logged in the anti-lock braking system
module, for additional diagnosis and testing information refer to the relevant Diagnosis and Testing Section. For
additional information, refer to: Anti-Lock Control - Stability Assist (206-09 Anti-Lock Control - Stability Assist,
Diagnosis and Testing).

DTC Description Possible Causes Action


C0021- Brake Booster No vacuum available Check integrity of brake booster vacuum hose.
09 Performance - from engine due to Check and install a new brake booster as required
Component split/leaking hose etc
Failures Brake booster servo
has failed due to lack
of vacuum

C0030- Left Front Tone Left front magnetic Check the left front magnetic pulse ring for
38 Wheel - Signal pulse ring damage or contamination. Clean or replace as
frequency damaged/contaminated required. If no damage/contamination found,
incorrect Incorrect component suspect wheel speed sensor. Refer to the Warranty
installed Policy and Procedures manual if a
Sensor internal fault module/component is suspect. To validate the
repair and extinguish the lamps, the vehicle needs
to be driven above 9mph/15kph for more than 10
seconds

C0031- Left Front Wheel Electrical wiring Refer to the electrical circuit diagrams and check
12 Speed Sensor - harness fault the wheel speed sensor circuit for short to power.
Short to battery Sensor internal fault Repair harness as required. If no harness fault
found, suspect wheel speed sensor. Refer to the
Warranty Policy and Procedures manual if a
module/component is suspect

C0031- Left Front Wheel Electrical wiring Refer to the electrical circuit diagrams and check
14 Speed Sensor - harness fault the wheel speed sensor circuit for short to ground
Circuit short to Sensor internal fault or open circuit. Repair harness as required. If no
ground or open harness fault found, suspect wheel speed sensor.
Refer to the Warranty Policy and Procedures
manual if a module/component is suspect

C0031- Left Front Wheel Electrical wiring Refer to the electrical circuit diagrams and check
25 Speed Sensor - harness fault the wheel speed sensor circuit for partial or
Signal Sensor internal fault intermittently grounded signal circuit. Repair
shape/waveform harness as required. If no harness fault found,
failure suspect wheel speed sensor. Refer to the Warranty
Policy and Procedures manual if a
module/component is suspect. To validate the
repair and extinguish the lamps, the vehicle needs
to be driven above 9mph/15kph

C0031- Left Front Wheel Electrical wiring Refer to the electrical circuit diagrams and check
2F Speed Sensor - harness fault the wheel speed sensor circuit for intermittent
Signal erratic Sensor internal fault short to power, ground or open circuit. Repair
harness as required. If no harness fault found,
suspect wheel speed sensor. Refer to the Warranty
Policy and Procedures manual if a
module/component is suspect. To validate the
repair and extinguish the lamps, the vehicle needs
to be driven above 9mph/15kph

C0031- Left Front Wheel Electrical wiring Refer to the electrical circuit diagrams and check
31 Speed Sensor - harness fault the wheel speed sensor circuit for open circuit or
No signal Magnetic pulse ring de- high resistance. Check connectors for damage or
magnetised or damaged corrosion. Check the wheel speed sensor for
Sensor internal fault correct location and contamination. Check the
magnetic pulse wheel for contamination, damage
or de-magnetisation. Clean or replace the sensor
or wheel bearing as required. Refer to the
Warranty Policy and Procedures manual if a
module/component is suspect. To validate the
repair and extinguish the lamps, the vehicle needs
to be driven above 9mph/15kph

C0031- Left Front Wheel Electrical wiring Refer to the electrical circuit diagrams and check
62 Speed Sensor - harness fault the wheel speed sensor circuit for intermittent
Signal compare Sensor internal fault short to power, ground or open circuit. Repair
failure harness as required. If no harness fault found,
suspect wheel speed sensor. Refer to the Warranty
Policy and Procedures manual if a
module/component is suspect. To validate the
repair and extinguish the lamps, the vehicle needs
to be driven above 9mph/15kph

C0031- Left Front Wheel Incorrect wheels/tyres Check the correct wheels and tyres are installed.
64 Speed Sensor - installed Refer to the electrical circuit diagrams and check
Signal Electrical wiring the wheel speed sensor circuit for intermittent
plausibility harness fault short to power, or ground. Check for EMC
failure EMC influences on left influences on the speed sensor and circuits. Check
front wheel speed magnetic pulse wheel for damage/contamination
sensor and supply line and de-magnetisation. Repair Wiring harness,
Magnetic pulse wheel install a new sensor or wheel bearing as required.
damaged/contaminated, Refer to the Warranty Policy and Procedures
de-magnetised manual if a module/component is suspect
Sensor internal fault

C0032- Left Front wheel Electrical wiring Refer to the electrical circuit diagrams and check
11 Speed Sensor harness fault the wheel speed sensor circuit for short to ground.
Supply - Circuit Sensor internal fault Repair harness as required. If no harness fault
short to ground found, suspect wheel speed sensor. Refer to the
Warranty Policy and Procedures manual if a
module/component is suspect

C0033- Right Front Tone Right front magnetic Check the right front magnetic pulse ring for
38 Wheel - Signal pulse ring damage or contamination. Clean or replace as
frequency damaged/contaminated required. If no damage/contamination found,
incorrect Incorrect component suspect wheel speed sensor. Refer to the Warranty
installed Policy and Procedures manual if a
Sensor internal fault module/component is suspect. To validate the
repair and extinguish the lamps, the vehicle needs
to be driven above 9mph/15kph for more than 10
seconds

C0034- Right Front Electrical wiring Refer to the electrical circuit diagrams and check
12 Wheel Speed harness fault the wheel speed sensor circuit for short to power.
Sensor - Short to Sensor internal fault Repair harness as required. If no harness fault
battery found, suspect wheel speed sensor. Refer to the
Warranty Policy and Procedures manual if a
module/component is suspect

C0034- Right Front Electrical wiring Refer to the electrical circuit diagrams and check
14 Wheel Speed harness fault the wheel speed sensor circuit for short to ground
Sensor - Circuit Sensor internal fault or open circuit. Repair harness as required. If no
short to ground harness fault found, suspect wheel speed sensor.
or open Refer to the Warranty Policy and Procedures
manual if a module/component is suspect
C0034- Right Front Electrical wiring Refer to the electrical circuit diagrams and check
25 Wheel Speed harness fault the wheel speed sensor circuit for partial or
Sensor - Signal Sensor internal fault intermittently grounded signal circuit. Repair
shape/waveform harness as required. If no harness fault found,
failure suspect wheel speed sensor. Refer to the Warranty
Policy and Procedures manual if a
module/component is suspect. To validate the
repair and extinguish the lamps, the vehicle needs
to be driven above 9mph/15kph

C0034- Right Front Electrical wiring Refer to the electrical circuit diagrams and check
2F Wheel Speed harness fault the wheel speed sensor circuit for intermittent
Sensor - Signal Sensor internal fault short to power, ground or open circuit. Repair
erratic harness as required. If no harness fault found,
suspect wheel speed sensor. Refer to the Warranty
Policy and Procedures manual if a
module/component is suspect. To validate the
repair and extinguish the lamps, the vehicle needs
to be driven above 9mph/15kph

C0034- Right Front Electrical wiring Refer to the electrical circuit diagrams and check
31 Wheel Speed harness fault the wheel speed sensor circuit for open circuit or
Sensor - No Magnetic pulse ring de- high resistance. Check connectors for damage or
signal magnetised or damaged corrosion. Check the wheel speed sensor for
Sensor internal fault correct location and contamination. Check the
magnetic pulse wheel for contamination, damage
or de-magnetisation. Clean or replace the sensor
or wheel bearing as required. Refer to the
Warranty Policy and Procedures manual if a
module/component is suspect. To validate the
repair and extinguish the lamps, the vehicle needs
to be driven above 9mph/15kph

C0034- Right Front Electrical wiring Refer to the electrical circuit diagrams and check
62 Wheel Speed harness fault the wheel speed sensor circuit for intermittent
Sensor - Signal Sensor internal fault short to power, ground or open circuit. Repair
compare failure harness as required. If no harness fault found,
suspect wheel speed sensor. Refer to the Warranty
Policy and Procedures manual if a
module/component is suspect. To validate the
repair and extinguish the lamps, the vehicle needs
to be driven above 9mph/15kph

C0034- Right Front Incorrect wheels/tyres Check the correct wheels and tyres are installed.
64 Wheel Speed installed Refer to the electrical circuit diagrams and check
Sensor - Signal Electrical wiring the wheel speed sensor circuit for intermittent
plausibility harness fault short to power, or ground. Check for EMC
failure EMC influences on influences on the speed sensor and circuits. Check
right front wheel speed magnetic pulse wheel for damage/contamination
sensor and supply line and de-magnetisation. Repair wiring harness,
Magnetic pulse wheel install a new sensor or wheel bearing as required.
damaged/contaminated, Refer to the Warranty Policy and Procedures
de-magnetised manual if a module/component is suspect
Sensor internal fault
C0035- Right Front Electrical wiring Refer to the electrical circuit diagrams and check
11 Wheel Speed harness fault the wheel speed sensor circuit for short to ground.
Sensor Supply - Sensor internal fault Repair harness as required. If no harness fault
Circuit short to found, suspect wheel speed sensor. Refer to the
ground Warranty Policy and Procedures manual if a
module/component is suspect

C0036- Left Rear Tone Left rear magnetic Check the left rear magnetic pulse ring for
38 Wheel - Signal pulse ring damage or contamination. Clean or replace as
frequency damaged/contaminated required. If no damage/contamination found,
incorrect Incorrect component suspect wheel speed sensor. Refer to the Warranty
installed Policy and Procedures manual if a
Sensor internal fault module/component is suspect. To validate the
repair and extinguish the lamps, the vehicle needs
to be driven above 9mph/15kph for more than 10
seconds

C0037- Left Rear Wheel Electrical wiring Refer to the electrical circuit diagrams and check
12 Speed Sensor - harness fault the wheel speed sensor circuit for short to power.
Short to battery Sensor internal fault Repair harness as required. If no harness fault
found, suspect wheel speed sensor. Refer to the
Warranty Policy and Procedures manual if a
module/component is suspect

C0037- Left Rear Wheel Electrical wiring Refer to the electrical circuit diagrams and check
14 Speed Sensor - harness fault the wheel speed sensor circuit for short to ground
Circuit short to Sensor internal fault or open circuit. Repair harness as required. If no
ground or open harness fault found, suspect wheel speed sensor.
Refer to the Warranty Policy and Procedures
manual if a module/component is suspect

C0037- Left Rear Wheel Electrical wiring Refer to the electrical circuit diagrams and check
25 Speed Sensor - harness fault the wheel speed sensor circuit for partial or
Signal Sensor internal fault intermittently grounded signal circuit. Repair
shape/waveform harness as required. If no harness fault found,
failure suspect wheel speed sensor. Refer to the Warranty
Policy and Procedures manual if a
module/component is suspect. To validate the
repair and extinguish the lamps, the vehicle needs
to be driven above 9mph/15kph

C0037- Left Rear Wheel Electrical wiring Refer to the electrical circuit diagrams and check
2F Speed Sensor - harness fault the wheel speed sensor circuit for intermittent
Signal erratic Sensor internal fault short to power, ground or open circuit. Repair
harness as required. If no harness fault found,
suspect wheel speed sensor. Refer to the Warranty
Policy and Procedures manual if a
module/component is suspect. To validate the
repair and extinguish the lamps, the vehicle needs
to be driven above 9mph/15kph

C0037- Left Rear Wheel Electrical wiring Refer to the electrical circuit diagrams and check
31 Speed Sensor - harness fault the wheel speed sensor circuit for open circuit or
No signal Magnetic pulse ring de- high resistance. Check connectors for damage or
magnetised or damaged corrosion. Check the wheel speed sensor for
Sensor internal fault correct location and contamination. Check the
magnetic pulse wheel for contamination, damage
or de-magnetisation. Clean or replace the sensor
or wheel bearing as required. Refer to the
Warranty Policy and Procedures manual if a
module/component is suspect. To validate the
repair and extinguish the lamps, the vehicle needs
to be driven above 9mph/15kph

C0037- Left Rear Wheel Electrical wiring Refer to the electrical circuit diagrams and check
62 Speed Sensor - harness fault the wheel speed sensor circuit for intermittent
Signal compare Sensor internal fault short to power, ground or open circuit. Repair
failure harness as required. If no harness fault found,
suspect wheel speed sensor. Refer to the Warranty
Policy and Procedures manual if a
module/component is suspect. To validate the
repair and extinguish the lamps, the vehicle needs
to be driven above 9mph/15kph

C0037- Left Rear Wheel Incorrect wheels/tyres Check the correct wheels and tyres are installed.
64 Speed Sensor - installed Refer to the electrical circuit diagrams and check
Signal Electrical wiring the wheel speed sensor circuit for intermittent
plausibility harness fault short to power, or ground. Check for EMC
failure EMC influences on left influences on the speed sensor and circuits. Check
rear wheel speed sensor magnetic pulse wheel for damage/contamination
and supply line and de-magnetisation. Repair Wiring harness,
Magnetic pulse wheel install a new sensor or wheel bearing as required.
damaged/contaminated, Refer to the Warranty Policy and Procedures
de-magnetised manual if a module/component is suspect
Sensor internal fault

C0038- Left Rear Wheel Electrical wiring Refer to the electrical circuit diagrams and check
11 Speed Sensor harness fault the wheel speed sensor circuit for short to ground.
Supply - Circuit Sensor internal fault Repair harness as required. If no harness fault
short to ground found, suspect wheel speed sensor. Refer to the
Warranty Policy and Procedures manual if a
module/component is suspect

C0039- Right Rear Tone Right rear magnetic Check the right rear magnetic pulse ring for
38 Wheel - Signal pulse ring damage or contamination. Clean or replace as
frequency damaged/contaminated required. . If no damage/contamination found,
incorrect Incorrect component suspect wheel speed sensor. Refer to the Warranty
installed Policy and Procedures manual if a
Sensor internal fault module/component is suspect. To validate the
repair and extinguish the lamps, the vehicle needs
to be driven above 9mph/15kph for more than 10
seconds

C003A- Right Rear Electrical wiring Refer to the electrical circuit diagrams and check
12 Wheel Speed harness fault the wheel speed sensor circuit for short to power.
Sensor - Short to Sensor internal fault Repair harness as required. If no harness fault
battery found, suspect wheel speed sensor. Refer to the
Warranty Policy and Procedures manual if a
module/component is suspect

C003A- Right Rear Electrical wiring Refer to the electrical circuit diagrams and check
14 Wheel Speed harness fault the wheel speed sensor circuit for short to ground
Sensor - Circuit Sensor internal fault or open circuit. Repair harness as required. If no
short to ground harness fault found, suspect wheel speed sensor.
or open Refer to the Warranty Policy and Procedures
manual if a module/component is suspect

C003A- Right Rear Electrical wiring Refer to the electrical circuit diagrams and check
25 Wheel Speed harness fault the wheel speed sensor circuit for partial or
Sensor - Signal Sensor internal fault intermittently grounded signal circuit. Repair
shape/waveform harness as required. If no harness fault found,
failure suspect wheel speed sensor. Refer to the Warranty
Policy and Procedures manual if a
module/component is suspect. To validate the
repair and extinguish the lamps, the vehicle needs
to be driven above 9mph/15kph

C003A- Right Rear Electrical wiring Refer to the electrical circuit diagrams and check
2F Wheel Speed harness fault the wheel speed sensor circuit for intermittent
Sensor - Signal Sensor internal fault short to power, ground or open circuit. Repair
erratic harness as required. If no harness fault found,
suspect wheel speed sensor. Refer to the Warranty
Policy and Procedures manual if a
module/component is suspect. To validate the
repair and extinguish the lamps, the vehicle needs
to be driven above 9mph/15kph

C003A- Right Rear Electrical wiring Refer to the electrical circuit diagrams and check
31 Wheel Speed harness fault the wheel speed sensor circuit for open circuit or
Sensor - No Magnetic pulse ring de- high resistance. Check connectors for damage or
signal magnetised or damaged corrosion. Check the wheel speed sensor for
Sensor internal fault correct location and contamination. Check the
magnetic pulse wheel for contamination, damage
or de-magnetisation. Clean or replace the sensor
or wheel bearing as required. Refer to the
Warranty Policy and Procedures manual if a
module/component is suspect. To validate the
repair and extinguish the lamps, the vehicle needs
to be driven above 9mph/15kph

C003A- Right Rear Electrical wiring Refer to the electrical circuit diagrams and check
62 Wheel Speed harness fault the wheel speed sensor circuit for intermittent
Sensor - Signal Sensor internal fault short to power, ground or open circuit. Repair
compare failure harness as required. If no harness fault found,
suspect wheel speed sensor. Refer to the Warranty
Policy and Procedures manual if a
module/component is suspect. To validate the
repair and extinguish the lamps, the vehicle needs
to be driven above 9mph/15kph

C003A- Right Rear Incorrect wheels/tyres Check the correct wheels and tyres are installed.
64 Wheel Speed installed Refer to the electrical circuit diagrams and check
Sensor - Signal Electrical wiring the wheel speed sensor circuit for intermittent
plausibility harness fault short to power, or ground. Check for EMC
failure EMC influences on left influences on the speed sensor and circuits. Check
rear wheel speed sensor magnetic pulse wheel for damage/contamination
and supply line and de-magnetisation. Repair Wiring harness,
Magnetic pulse wheel install a new sensor or wheel bearing as required.
damaged/contaminated, Refer to the Warranty Policy and Procedures
de-magnetised manual if a module/component is suspect
Sensor internal fault

C003B- Right Rear Electrical wiring Refer to the electrical circuit diagrams and check
11 Wheel Speed harness fault the wheel speed sensor circuit for short to ground.
Sensor Supply - Sensor internal fault Repair harness as required. If no harness fault
Circuit short to found, suspect wheel speed sensor. Refer to the
ground Warranty Policy and Procedures manual if a
module/component is suspect

C0047- Brake Booster Brake booster pressure Carry out any pinpoint test associated with this
16 Pressure Sensor - sensor supply circuit - DTC using the manufacturer approved diagnostic
Circuit voltage Voltage below system. Refer to the electrical circuit diagrams
below threshold threshold and check brake booster pressure sensor power
HCU failure supply for short to ground. Check and install a
new HCU as required, refer to the new
module/component installation note at the top of
the DTC Index

C0047- Brake Booster Brake booster pressure Carry out any pinpoint test associated with this
1C Pressure Sensor - sensor supply circuit - DTC using the manufacturer approved diagnostic
Circuit voltage Voltage out of range system. Refer to the electrical circuit diagrams
out of range 4.5v-5.3v and check brake booster pressure sensor power
Brake booster pressure supply for short, high resistance. Establish if
sensor failure sensor or HCU is at fault. Check and install a new
HCU failure brake booster pressure sensor or HCU as required,
refer to the new module/component installation
note at the top of the DTC Index

C0047- Brake Booster Brake booster pressure Carry out any pinpoint test associated with this
29 Pressure Sensor - sensor signal 1 circuit - DTC using the manufacturer approved diagnostic
Signal invalid short to ground, power, system. Refer to the electrical circuit diagrams
open circuit and check brake booster signal 1 and 2 circuits for
Brake booster pressure short to ground, power, open circuit. Clear DTC
sensor signal 2 circuit - and re-test. If DTC remains, suspect the brake
short to ground, power, booster pressure sensor, check and install a new
open circuit sensor as required, refer to the new
Brake booster pressure module/component installation note at the top of
sensor failure the DTC Index. To validate the repair and
extinguish the lamps, start the engine and apply
the foot brake

C0047- Brake Booster NOTE: Carry out any pinpoint test associated with this
62 Pressure Sensor - DTC using the manufacturer approved diagnostic
Signal compare Fault detected during braking system. Refer to the electrical circuit diagrams
failure event and check brake booster pressure sensor signal
circuits 1 and 2 for shorting together. Repair any
Brake booster pressure harness faults found and retest. To validate the
sensor signal circuits 1 repair and extinguish the lamps, start the engine
and 2 - shorted together and apply the foot brake

C0047- Brake Booster NOTE: Carry out any pinpoint test associated with this
64 Pressure Sensor - DTC using the manufacturer approved diagnostic
Signal Fault detected during non- system. Refer to the electrical circuit diagrams
plausibility braking event and check brake booster signal 1 and 2 circuits for
failure short to ground, power, open circuit or high
Signal plausibility resistance. Check connectors for damage or
failure corrosion. Repair any harness faults found and
Electrical wiring retest. If DTC remains, suspect the brake booster
harness fault pressure sensor, check and install a new sensor as
Brake booster pressure required, refer to the new module/component
sensor failure installation note at the top of the DTC Index. To
validate the repair and extinguish the lamps, start
the engine and apply and release the foot brake

C0062- Longitudinal Yaw sensor insecurely Check the yaw sensor is securely mounted. If the
28 Acceleration mounted mounting is secure suspect the yaw sensor, Refer
Sensor - Signal Yaw sensor fault to the Warranty Policy and Procedures manual if a
bias level out of module/component is suspect
range/zero
adjustment
failure
C0062- Longitudinal The longitudinal Check the longitudinal acceleration sensor has
54 Acceleration acceleration sensor has been calibrated
Sensor - Missing not been calibrated If it has been calibrated check that the sensor is
calibration Mounting bracket aligned correctly, check for bent mounting bracket
bent/misaligned To validate the calibration/repair, ignition on and
wait 10 seconds. Check lamps remain
extinguished

C0063- Yaw Rate Sensor Wiring harness fault Refer to the electrical wiring diagrams and check
08 - Bus signal Yaw sensor fault the integrity of the power and ground supplies to
/message failures the yaw sensor. Check the integrity of the bus
connections. Repair any harness faults found and
retest. If no harness faults are found suspect the
yaw sensor, Refer to the Warranty Policy and
Procedures manual if a module/component is
suspect. To validate the repair, ignition on and
wait 10 seconds. Check lamps remain
extinguished.

C0063- Yaw Rate Sensor Wiring harness fault Refer to the electrical wiring diagrams and check
14 - Circuit short to Sensor fault the high speed CAN circuit between the yaw
ground or open sensor and the Anti-Lock Braking System
Hydraulic Control Unit for short to ground or
open circuit. Repair any harness faults found and
retest. If no harness faults are found suspect the
yaw sensor, Refer to the Warranty Policy and
Procedures manual if a module/component is
suspect

C0063- Yaw Rate Sensor Yaw rate sensor power Refer to the electrical wiring diagrams and check
1C - Circuit voltage distribution fault the power and ground supplies to the yaw sensor.
out of range Wiring harness fault Check power circuit for short to ground or open
Yaw sensor internal circuit. Check ground circuit for short to power or
fault open circuit. Repair any harness faults found and
retest. If no harness faults are found suspect the
yaw sensor, Refer to the Warranty Policy and
Procedures manual if a module/component is
suspect
To confirm the repair and extinguish the warning
lamps, clear the DTC, cycle the ignition state to
off, then return the ignition state to on and wait up
to 10 seconds

C0063- Yaw Rate Sensor Yaw sensor insecurely Check the yaw sensor is securely mounted. Check
27 - Signal rate of mounted the yaw sensor harness connector is securely
change Yaw sensor connector located. Refer to the electrical wiring diagrams
insecure and check the power and ground supplies to the
Wiring harness fault yaw sensor. Check circuits for intermittent open
Yaw sensor fault circuit or high resistance. Repair any harness
Anti-Lock Braking faults found and retest. If no harness faults are
System Hydraulic found suspect the yaw sensor or Anti-Lock
Control Unit fault Braking System Hydraulic Control Unit, Refer to
the Warranty Policy and Procedures manual if a
module/component is suspect

C0063- Yaw Rate Sensor Yaw sensor insecurely Check the yaw sensor is securely mounted. If the
28 - Signal bias mounted mounting is secure suspect the yaw sensor, Refer
level out of Yaw sensor fault to the Warranty Policy and Procedures manual if a
range/zero module/component is suspect
adjustment
failure
C0063- Yaw Rate Sensor Yaw sensor fault Replace the yaw sensor, clear the DTC and retest
41 - Checksum error Anti-Lock Braking the system. If the DTC remains install a new Anti-
System Hydraulic Lock Braking System Hydraulic Control Unit.
Control Unit fault Refer to the Warranty Policy and Procedures
manual if a module/component is suspect
To confirm the repair and extinguish the warning
lamps, clear the DTC, cycle the ignition state to
off, then return the ignition state to on and wait up
to 10 seconds

C0063- Yaw Rate Sensor Yaw rate sensor Refer to the electrical wiring diagrams and check
49 - Internal internal electronic the power and ground supplies to the yaw sensor.
electronic failure failure Repair any harness faults found and retest. If no
Wiring harness fault harness faults are found suspect the yaw sensor,
Refer to the Warranty Policy and Procedures
manual if a module/component is suspect
To confirm the repair and extinguish the warning
lamps, clear the DTC, cycle the ignition state to
off, then return the ignition state to on and wait up
to 10 seconds

C0063- Yaw Rate Sensor The vehicle has been NOTE:


64 - Signal operated on a
plausibility dynamometer/rolling This DTC can be set if the vehicle is operated on a
failure road dynamometer/rolling road, if this is the case the DTC
Yaw rate sensor should be stored as a historic DTC
incorrectly installed
Yaw rate sensor fault This DTC is set if the information coming from
the yaw sensor is deemed to be implausible when
compared with other sensor information such as
steering angle sensor. Check that the yaw sensor
is correctly installed on the vehicle. If the sensor
is installed correctly suspect the sensor has an
internal fault. Refer to the Warranty Policy and
Procedures manual if a module/component is
suspect

C0063- Yaw Rate Sensor Incorrect yaw sensor Check the part number of the yaw sensor and fit
95 - Incorrect installed the correct sensor as required
assembly To confirm the repair and extinguish the warning
lamps, clear the DTC, cycle the ignition state to
off, then return the ignition state to on and wait up
to 10 seconds

C101F- Generic Valve Anti-Lock Braking Refer to the Warranty Policy and Procedures
49 Failure - Internal System Hydraulic manual if a module/component is suspect. Check
electronic failure Control Unit fault and install a new Anti-Lock Braking System
Hydraulic Control Unit

C1A77- Valve Relay Valve relay supply Refer to the electrical wiring diagrams and check
16 Supply Circuit - circuit fault the valve relay supply circuit for open circuit or
Voltage below Valve relay ground short to ground. Check the valve relay ground
threshold circuit fault circuit for open circuit
To confirm the repair and extinguish the warning
lamps, clear the DTC, cycle the ignition state to
off, then return the ignition state to on and wait up
to 10 seconds. If required road test the vehicle at a
speed above 20 KPH

C1A90- Wheel Speed Wiring harness fault This DTC is set if at least one wheel speed sensor
12 Sensor Supply - supply circuit is short to power. Refer to the
Circuit short to electrical wiring diagrams and check the wheel
battery speed sensor circuits for short to power. Repair
wiring harness as required. Clear the DTC and
retest the system

C1A95- Wheel Speed Incorrect wheel speed Check and install the correct wheel speed sensor
4A Sensor - sensor installed To confirm the repair and extinguish the warning
Incorrect lamps, clear the DTC, cycle the ignition state to
component off, then return the ignition state to on and wait up
installed to 30 seconds

C1A95- Wheel Speed Incorrect wheels/tyres NOTE:


64 Sensor - Signal installed
plausibility Electrical wiring This DTC could be set by a flat tyre which would give a
failure harness fault continuous different rate of speed when compared to
Magnetic pulse wheel other 3 wheels, if this is the case the DTC should be
damaged/contaminated stored as a historic DTC
or de-magnetised
EMC influences on Check that approved wheels and tyres are
wheel speed sensors installed. Refer to the electrical circuit diagrams
and supply circuits and check the wheel speed sensor circuits for
Wheel speed sensor intermittent short to power, or ground. Check the
internal fault wheel speed sensors and pulse wheels for
contamination/damage or de-magnetisation. Clear
the DTC and retest the vehicle. If the fault
remains check the wheel speed sensor circuits for
possible EMC interference. Examine the output
from the sensors using an oscilloscope to identify
inconsistent patterns or spikes. Repair wiring
harness or replace wheel speed sensors or wheel
bearings as required. Refer to the Warranty Policy
and Procedures manual if a module/component is
suspect

C1A96- Brake Light Brake pedal switch out This DTC is set when the signal from the brake
64 Switch - Signal of adjustment pedal position switch is contradicted by the signal
plausibility Brake pedal switch from the master cylinder pressure sensor. Check
failure circuit faults the adjustment of the brake pedal position switch.
Brake pedal switch Check the Engine Control Module for brake pedal
fault switch related DTCs. Check brake pedal switch
circuits for open circuit. Repair wiring as required
or install a replacement switch as required. Switch
the ignition state to on, press and release brake
pedal at least once

C1A97- Lateral Sensor Internal Fault This DTC is set when the lateral accelerometer
24 Accelerometer - produces an erroneous signal with the vehicle
Signal stuck high stationary. Suspect sensor, refer to the Warranty
Policy and Procedures manual if a
module/component is suspect

C1A98- Yaw Rate Sensor Internal electronic Check and install a new sensor as required, refer
49 - Internal failure to the Warranty Policy and Procedures manual if a
electronic failure module/component is suspect

C1A98- Yaw Rate Sensor NOTE: Check the Yaw rate sensor is correctly installed to
64 - Signal the vehicle. Check and install a new sensor as
plausibility This DTC may set due to a required, refer to the Warranty Policy and
failure sustained period of steep Procedures manual if a module/component is
uphill driving (>35% for four suspect
seconds)

Yaw rate sensor


incorrectly mounted to
the vehicle
Yaw rate sensor failure

C1A98- Yaw Rate Sensor Yaw rate sensor Check the mounting of the yaw rate sensor and
92 - Performance or incorrectly mounted to correct or replace sensor as required. Refer to the
incorrect the vehicle. Warranty Policy and Procedures manual if a
operation module/component is suspect

C1A98- Yaw Rate Sensor Yaw rate sensor Clear the DTC and retest the system. If the fault
96 - Component incorrectly installed remains check for additional DTCs and refer to
internal failure Yaw rate sensor wiring the DTC index. Check the Yaw sensor is mounted
fault correctly on the vehicle. Check the wiring
EMC influences on connections to the sensor are correct and secure.
yaw rate sensor and Check for any sources of EMC interference with
circuits the sensor or circuits. If no external causes are
Yaw rate sensor evident suspect the sensor. Refer to the Warranty
internal fault Policy and Procedures manual if a
module/component is suspect

C1A98- Yaw Rate Sensor The signal from the NOTE:


2F - Signal erratic yaw rate sensor has
been suspicious for > 2 This DTC may be stored even though no fault condition
minutes but has not yet is present and should be ignored. Clear the DTC and
moved fully to fault retest. Verify the customer concern prior to diagnosis
condition
Information only, regard as normal operation.
Clear the DTC and retest the system

C1A99- Pressure Sensor - Pedal box adjustment Check the pedal box is adjusted/operating
28 Signal bias level incorrect correctly, perform any necessary adjustments,
out of range / Pedal box fault clear DTC and retest system. If DTC resets
zero adjustment Anti-Lock Braking suspect Anti-Lock Braking System Control
failure System Control Module. Refer to the Warranty Policy and
Module fault Procedures manual if a module/component is
suspect

C1B00- Steering Angle Steering angle sensor The sensor is calibrated at every new ignition
16 Sensor - Circuit not initialised and cycle, every time the vehicle is driven away from
voltage below calibrated standstill. The DTC indicates that the steering
threshold Wiring harness fault offset exceeded allowed values and that the
Sensor internal fault calibration process was restarted. Check for a
disturbance of the ignition supply to the sensor.
Refer to the electrical circuit diagrams and check
the steering angle sensor wiring harness and
circuits for open circuits, short to ground. Refer to
the Warranty Policy and Procedures manual if a
module/component is suspect

C1B00- Steering Angle Wiring harness fault Refer to the electrical circuit diagrams and check
1C Sensor - Circuit Sensor internal fault the steering angle sensor wiring harness and
voltage out of sensor signal circuits for open circuits, short to
range power or ground. Refer to the Warranty Policy
and Procedures manual if a module/component is
suspect

C1B00- Steering Angle Harness fault Refer to the electrical circuit diagrams, check the
27 Sensor - Signal Sensor internal fault wiring harness connection at the steering angle
rate of change sensor for security and check circuits for
above threshold intermittent faults. Clear DTC and retest system.
The sensor is calibrated at every new ignition
cycle, every time the vehicle is driven away from
standstill. If fault returns suspect sensor. Refer to
the Warranty Policy and Procedures manual if a
module/component is suspect

C1B00- Steering Angle Steering angle sensor Check the installed position of the steering angle
49 Sensor - Internal not installed in the sensor. Remove and reinstall if required. Clear
electronic failure correct position DTC. The sensor is calibrated at every new
Steering angle sensor ignition cycle, every time the vehicle is driven
internal fault away from standstill. Retest system. If fault
returns suspect sensor. Refer to the Warranty
Policy and Procedures manual if a
module/component is suspect

C1B00- Steering Angle Steering angle sensor This DTC is set when there is conflicting
64 Sensor - Signal not installed in the information coming from the Steering Angle
plausibility correct position Sensor and the Yaw Rate Sensor. Check both of
failure Yaw rate sensor not these sensors to ensure they are correctly installed
installed in the correct on the vehicle. Check for other related DTCs.
position Clear the DTC. The sensor is calibrated at every
Steering angle sensor new ignition cycle, every time the vehicle is
internal fault driven away from standstill. If the DTC returns
suspect the Steering Angle Sensor. Refer to the
Warranty Policy and Procedures manual if a
module/component is suspect

C1B00- Steering Angle Wiring harness fault Refer to the electrical circuit diagrams and check
66 Sensor - Signal Steering angle sensor the steering angle circuits for short circuit to each
has too many internal fault other. If no harness faults are found suspect the
transitions/events steering angle sensor, refer to the Warranty Policy
and Procedures manual if a module/component is
suspect

C1B00- Steering Angle Conditions not met Information only, regard as normal operation.
68 Sensor - Event under which the sensor Clear the DTC and retest the system. Switch the
information can learn the centre ignition state to on, engine running, accelerate >
position 5.4 kph with steering input

C1B02- Return Pump - Wiring harness fault Refer to the electrical circuit diagrams and check
16 Circuit voltage the return pump supply and ground circuits for
below threshold short to ground or open circuit
To confirm the repair and extinguish the warning
lamps, clear the DTC, cycle the ignition state to
off, then return the ignition state to on and drive
the vehicle above 9mph/15kph

C1B02- Return Pump - Internal fault within the Install a new hydraulic control unit. Refer to the
49 Internal Anti-Lock Braking Warranty Policy and Procedures manual if a
electronic failure System Hydraulic module/component is suspect
Control Unit To confirm the repair and extinguish the warning
lamps, clear the DTC, cycle the ignition state to
off, then return the ignition state to on and drive
the vehicle above 9mph/15kph

C2009- Front Axle Vehicle unevenly Check the vehicle is not unevenly loaded (heavy
95 Wheel Speed loaded on one side). Check that approved wheels and
Sensors Incorrect tyres installed tyres are installed. Refer to electrical circuit
Swapped - Wiring harness fault diagrams and check if the front wheel speed
Incorrect sensor connectors are transposed or incorrectly
assembly attached at the wiring harness connector

C200A- Rear Axle Wheel Vehicle unevenly Check the vehicle is not unevenly loaded (heavy
95 Speed Sensors loaded on one side). Check that approved wheels and
Swapped - Incorrect tyres installed tyres are installed. Refer to electrical circuit
Incorrect Wiring harness fault diagrams and check if the rear wheel speed sensor
assembly connectors are transposed or incorrectly attached
at the wiring harness connector

U0001- High Speed Wiring harness fault Refer to the electrical circuit diagrams and check
88 CAN the power and ground connections to the module.
Communication Using the manufacturer approved diagnostic
bus - Bus off system, complete a CAN network integrity test.
Refer to the electrical circuit diagrams and check
the CAN network

U0074- Control Module Wiring harness fault Refer to the electrical circuit diagrams and check
13 Communication the power and ground connections to the module.
Bus B off - Refer to the electrical circuit diagrams and check
Circuit open the private CAN bus circuits between the Yaw
Rate Sensor and the Anti-Lock Braking System
control module for open circuit

U0074- Control Module Wiring harness fault Refer to the electrical circuit diagrams and check
88 Communication the power and ground connections to the module.
Bus B off - Bus Refer to the electrical circuit diagrams and check
off the private CAN bus circuits between the Yaw
Rate Sensor and the Anti-Lock Braking System
control module for short to ground, short to power
open circuit. check for insecure connectors

U0100- Lost Power distribution fault Refer to the electrical circuit diagrams and check
00 Communication Wiring harness fault the power and ground connections to the module.
With ECM/PCM Using the manufacturer approved diagnostic
A - No sub type system, complete a CAN network integrity test.
information Refer to the electrical circuit diagrams and check
the CAN network between the Engine Control
Module and the Anti-Lock Braking System
Control Module
To confirm the repair and extinguish the warning
lamps, clear the DTC, cycle the ignition state to
off, then return the ignition state to on and wait up
to 10 seconds

U0100- Lost Power distribution fault Refer to the electrical circuit diagrams and check
87 Communication Wiring harness fault the power and ground connections to the module.
With ECM/PCM Using the manufacturer approved diagnostic
"A" - Missing system, complete a CAN network integrity test.
message Refer to the electrical circuit diagrams and check
the CAN network between the Engine Control
Module and the Anti-Lock Braking System
Control Module
To confirm the repair and extinguish the warning
lamps, clear the DTC, cycle the ignition state to
off, then return the ignition state to on and wait up
to 10 seconds

U0101- Lost Power distribution fault Refer to the electrical circuit diagrams and check
00 Communication Wiring harness fault the power and ground connections to the module.
With TCM - No Using the manufacturer approved diagnostic
sub type system, complete a CAN network integrity test.
information Refer to the electrical circuit diagrams and check
the CAN network between the Transmission
Control Module and the Anti-Lock Braking
System Control Module

U0101- Lost Power distribution fault Refer to the electrical circuit diagrams and check
87 Communication Wiring harness fault the power and ground connections to the module.
with TCM - Using the manufacturer approved diagnostic
Missing message system, complete a CAN network integrity test.
Refer to the electrical circuit diagrams and check
the CAN network between the Transmission
Control Module and the Anti-Lock Braking
System Control Module

U0103- Lost Power distribution fault Refer to the electrical circuit diagrams and check
00 Communication Wiring harness fault the power and ground connections to the module.
With Gear Shift Using the manufacturer approved diagnostic
Control Module system, complete a CAN network integrity test.
A - No sub type Refer to the electrical circuit diagrams and check
information the CAN network between the Transmission Shift
Control Module and the Anti-Lock Braking
System Control Module

U0103- Lost Power distribution fault Refer to the electrical circuit diagrams and check
87 Communication Wiring harness fault the power and ground connections to the module.
With Gear Shift Using the manufacturer approved diagnostic
Module - system, complete a CAN network integrity test.
Missing message Refer to the electrical circuit diagrams and check
the CAN network between the Transmission Shift
Control Module and the Anti-Lock Braking
System Control Module

U0104- Lost Power distribution fault Refer to the electrical circuit diagrams and check
00 Communication Wiring harness fault the power and ground connections to the module.
With Cruise Using the manufacturer approved diagnostic
Control Module - system, complete a CAN network integrity test.
No sub type Refer to the electrical circuit diagrams and check
information the CAN network between the Adaptive Speed
Control Module and the Anti-Lock Braking
System Control Module

U0104- Lost Invalid brake demand NOTE:


87 Communication pressure received from
With Cruise the Adaptive Speed This DTC can be set by either lost communication over
Control Module - Control Module CAN or by the ABS receiving an invalid brake demand
Missing message Power distribution fault pressure from the Adaptive Speed Control Module
Wiring harness fault
Check for Adaptive Speed Control Module related
DTCs
Refer to the electrical circuit diagrams and check
the power and ground connections to the module.
Using the manufacturer approved diagnostic
system, complete a CAN network integrity test.
Refer to the electrical circuit diagrams and check
the CAN network between the Adaptive Speed
Control Module and the Anti-Lock Braking
System Control Module

U0123- Lost Power distribution fault Refer to the electrical circuit diagrams and check
00 Communication Wiring harness fault the power and ground connections to the Yaw
With Yaw Rate Sensor failure Rate Sensor. Refer to the electrical circuit
Sensor Module - diagrams and check the CAN network between
No sub type the Yaw Rate Sensor Module and the Anti-Lock
information Braking System Control Module
If no harness faults are found, suspect the yaw
rate sensor. Refer to the Warranty Policy and
Procedures manual if a module/component is
suspect
To confirm the repair and extinguish the warning
lamps, clear the DTC, cycle the ignition state to
off, then return the ignition state to on and wait up
to 10 seconds

U0123- Lost Yaw rate sensor HS Refer to the electrical circuit diagrams and check
87 Communication CAN circuit - open the power and ground connections to the Yaw
With Yaw Rate circuit Rate Sensor. Refer to the electrical circuit
Sensor Module - Yaw rate sensor diagrams and check the CAN network between
Missing message ignition supply circuit - the Yaw Rate Sensor Module and the Anti-Lock
short to ground, open Braking System Control Module
circuit If no harness faults are found, suspect the yaw
Sensor failure rate sensor. Refer to the Warranty Policy and
Procedures manual if a module/component is
suspect
To confirm the repair and extinguish the warning
lamps, clear the DTC, cycle the ignition state to
off, then return the ignition state to on and wait up
to 10 seconds

U0128- Lost Power distribution fault Refer to the electrical circuit diagrams and check
00 Communication Wiring harness fault the power and ground connections to the module.
With Park Brake Using the manufacturer approved diagnostic
Control Module - system, complete a CAN network integrity test.
No sub type Refer to the electrical circuit diagrams and check
information the CAN network between the Park Brake Control
Module and the Anti-Lock Braking System
Control Module

U0128- Lost Power distribution fault Refer to the electrical circuit diagrams and check
87 Communication Wiring harness fault the power and ground connections to the module.
With Park Brake Using the manufacturer approved diagnostic
Control Module - system, complete a CAN network integrity test.
Missing message Refer to the electrical circuit diagrams and check
the CAN network between the Park Brake Control
Module and the Anti-Lock Braking System
Control Module

U0139- Lost Power distribution fault Refer to the electrical circuit diagrams and check
00 Communication Wiring harness fault the power and ground connections to the module.
With Suspension Using the manufacturer approved diagnostic
Control Module system, complete a CAN network integrity test.
B - No sub type Refer to the electrical circuit diagrams and check
information the CAN network between the Anti-Lock Braking
System Control Module and the Adaptive
Damping Control Module

U0140- Lost Power distribution fault Refer to the electrical circuit diagrams and check
00 Communication Wiring harness fault the power and ground connections to the module.
With Central Using the manufacturer approved diagnostic
Junction Box - system, complete a CAN network integrity test.
No sub type Refer to the electrical circuit diagrams and check
information the CAN network between the Central Junction
Box and the Anti-Lock Braking System Control
Module

U0155- Lost Power distribution fault Refer to the electrical circuit diagrams and check
00 Communication Wiring harness fault the power and ground connections to the module.
With Instrument Using the manufacturer approved diagnostic
Panel Cluster system, complete a CAN network integrity test.
(IPC) Control Refer to the electrical circuit diagrams and check
Module - No sub the CAN network between the Anti-Lock Braking
type information System Control Module and the Instrument Panel
Cluster (IPC) Control Module

U0300- Internal Control The Anti-Lock Braking Check the Anti-Lock Braking System control
00 Module Software System Control module part number, install the correct part as
Incompatibility - Module is not required. Refer to the Warranty Policy and
No sub type compatible with the Procedures manual if a module/component is
information vehicle suspect
To confirm the repair and extinguish the warning
lamps, clear the DTC, cycle the ignition state to
off, then return the ignition state to on and wait up
to 10 seconds

U0401- Invalid Data Event information - Check the Engine Control Module for related
68 Received From engine control module DTCs and refer to the relevant DTC index
ECM/PCM - related concern To confirm the repair and extinguish the warning
Event lamps, clear the DTC, cycle the ignition state to
information off, then return the ignition state to on and wait up
to 10 seconds

U0402- Invalid Data Event information - Check the Transmission Control Module for
68 Received From Transmission Control related DTCs and refer to the relevant DTC index
Transmission Module related concern
Control Module -
Event
information
U0404- Invalid Data Event information - Check the Transmission Shift Module for
68 Received From transmission shift Dynamic Stability Control switch related DTCs
Gear Shift module related concern and refer to the relevant DTC index
Module A -
Event
information
U0405- Invalid Data Event information - Check the Speed Control Module for related
68 Received From speed control module DTCs and refer to the relevant DTC index
Cruise Control related concern
Module - Event
information
U0417- Invalid Data Event information - Check the Electric Park Brake Control Module for
68 Received From electric park brake related DTCs and refer to the relevant DTC index
Park Brake control module related
Control Module - concern
Event
information
U0443- Invalid Data Event information Check the RJB for related DTCs and refer to the
68 Received From relevant DTC Index
Body Control
Module "B" -
Event
information
U1A14- CAN Power distribution fault Refer to the electrical circuit diagrams and check
00 Initialisation Wiring harness fault the power and ground connections to the module.
Failure - No sub Using the manufacturer approved diagnostic
type information system, complete a CAN network integrity test.
Refer to the electrical circuit diagrams and check
the CAN network

U2001- Reduced System Event information - Refer to the Warranty Policy and Procedures
68 Function - Event The pump motor wear manual if a module/component is suspect. Check
information estimator has reached a and install a new Anti-Lock Braking System
preset limit which Hydraulic Control Unit as required
mean that the Anti-
Lock Braking System
control module will no
longer support adaptive
speed control

U200D- Control Module Wiring harness fault NOTE:


14 Output Power A Vacuum boost pressure
- Circuit short to sensor failure (V6 This monitoring is based on detecting that the supply
ground or open petrol variants only) voltage from the ABS modulator is out of range (4.5V –
Steering angle sensor 5.3 V)
fault
HCU failure Refer to the electrical circuit diagrams and check
the power and ground connections to the Anti-
Lock Braking System Control Module. Check the
circuits between the steering angle sensor and the
Anti-Lock Braking System Control Module, in
particular check the steering angle sensor ground
at the Anti-Lock Braking System Control Module
connector pin. On V6 Petrol variants check the
circuits between the vacuum boost pressure sensor
and the Anti-Lock Braking System Control
Module, in particular check the vacuum boost
pressure sensor power supply at the Anti-Lock
Braking System Control Module connector pin. If
no wiring harness faults are found and the power
and ground supplies to the vacuum boost pressure
sensor, steering angle sensor and Anti-Lock
Braking System Control Module are ok then
suspect (1) the vacuum boost pressure sensor, (2)
the steering angle sensor, (3) the Anti-Lock
Braking System Control Module. Refer to the
Warranty Policy and Procedures manual if a
module/component is suspect

U2101- Control Module Anti-Lock Braking Check/amend the car configuration file in the
00 configuration System Control Central Junction Box using the manufacturer
Incompatible - Module variant code approved diagnostic system
No sub type value not supported on
information this vehicle

U2101- Control Module Anti-Lock Braking NOTE:


68 configuration System Control
Incompatible - Module has been The DTC is only for information and the system will
Event substituted from have full functionality
information another vehicle
A new Anti-Lock Check if the Anti-Lock Braking System Control
Braking System Module has been previously installed to another
Control Module has vehicle, if so: Install the correct Anti-Lock
been installed Braking System Control Module for this vehicle.
If the Anti-Lock Braking System Control Module
is new, cycle the ignition ON/OFF and clear the
DTC. Retest the system

U2300- Central Configuration missing Check/amend the car configuration file using the
54 Configuration - manufacturer approved diagnostic system
Missing
calibration
U3000- Control Module - Anti-Lock Braking Check Anti-Lock Braking System Control
45 Program System Control Module, clear DTC and retest system. If the fault
memory failure Module memory failure returns install a new Anti-Lock Braking System
Hydraulic control Unit. Refer to the Warranty
Policy and Procedures manual if a
module/component is suspect

U3000- Control Module - Anti-Lock Braking Refer to the Warranty Policy and Procedures
49 Internal System Control manual if a module/component is suspect. Install
electronic failure Module internal a new Anti-Lock Braking System Hydraulic
electronic failure Control Unit

U3000- Control Module - Anti-Lock Braking NOTE:


4B Over System valve overheat
temperature protection has been This DTC may be set if the manufacturer approved
activated diagnostic system has been operating the valves for a
prolonged period

Allow the Anti-Lock Braking System Hydraulic


Control Unit to cool, Clear the DTC and retest the
system

U3000- Control Module - Event information - Check for other DTCs relating to wheel speed,
68 Event Anti-Lock Braking yaw rate, steering angle and component failures.
information System intervention in Refer to the Warranty Policy and Procedures
progress for an manual if a module/component is suspect
unfeasible length of
time

U3000- Control Module - Error/mismatch in Car Download the Car Configuration File from the
87 Missing message Configuration file RJB using the manufacturer approved diagnostic
system, check and amend to suit vehicle
specification

U3002- Vehicle The Anti-Lock Braking NOTE:


81 Identification System Hydraulic
Number - Invalid Control Unit has The module will continue to work normally even with
serial data previously been the stored DTC
received installed to another
vehicle Check and install the original, or a new Anti-Lock
Braking System Hydraulic Control Unit. Refer to
the Warranty Policy and Procedures manual if a
module/component is suspect

U3003- Battery Voltage - There is a difference of Refer to the electrical circuit diagrams and check
62 Signal compare more than 2 volts the power and ground supply circuits to the
failure between the power Central Junction Box and the Anti-Lock Braking
supply to the Anti- System Hydraulic Control Unit. Repair wiring as
Lock Braking System required, clear the DTC and retest the system
Hydraulic Control Unit
and the Central
Junction Box

U3006- Control Module Power supply voltage Refer to the electrical circuit diagrams and check
16 Input Power A - low at Anti-Lock the power and ground supply circuits to the Anti-
Circuit voltage Braking System Lock Braking System Hydraulic Control Unit for
below threshold Hydraulic Control Unit open circuit, short to ground. Repair wiring as
required, clear the DTC and retest the system

U3006- Control Module Power supply voltage Suspect overcharging. Check the Engine Control
17 Input Power A - high at Anti-Lock Module for charging related DTCs and refer to the
Circuit voltage Braking System relevant DTC index. Refer to the workshop
above threshold Hydraulic Control Unit manual and battery care manual and check the
vehicle charging circuit performance. Rectify any
charging circuit concerns and clear the DTC.
Retest the system

U3006- Control Module Power supply voltage Refer to the electrical circuit diagrams and check
1C Input Power A - momentarily low at the the power and ground supply circuits to the Anti-
Circuit voltage Anti-Lock Braking Lock Braking System Hydraulic Control Unit for
out of range System Hydraulic intermittent open circuit, short to ground, or high
Control Unit resistance. Check the Engine Control Module for
charging related DTCs and refer to the relevant
DTC index. Refer to the workshop manual and
battery care manual and check the vehicle battery
condition and charging circuit performance.
Rectify any battery or charging circuit concerns
and clear the DTC. Retest the system
Published: 17-Apr-2014

2012.0 XF (X250), 100-00

General Information

Diagnostic Trouble Code Index - DTC: Audio


Amplifier Module (AAM) (G1426776)
DESCRIPTION AND OPERATION
Audio Amplifier Module (AAM)
CAUTION:

Diagnosis by substitution from a donor vehicle is NOT acceptable. Substitution of control modules does not
guarantee confirmation of a fault, and may also cause additional faults in the vehicle being tested and/or the donor
vehicle

NOTES:

If the control module or a component is suspect and the vehicle remains under manufacturer warranty, refer to
the warranty policy and procedures manual, or determine if any prior approval programme is in operation,
prior to the installation of a new module/component

Generic scan tools may not read the codes listed, or may read only 5-digit codes. Match the 5 digits from the
scan tool to the first 5 digits of the 7-digit code listed to identify the fault (the last 2 digits give extra
information read by the manufacturer-approved diagnostic system)

When performing voltage or resistance tests, always use a digital multimeter accurate to three decimal places
and with a current calibration certificate. When testing resistance, always take the resistance of the digital
multimeter leads into account

Check and rectify basic faults before beginning diagnostic routines involving pinpoint tests

Inspect connectors for signs of water ingress, and pins for damage and/or corrosion

If diagnostic trouble codes are recorded and, after performing the pinpoint tests, a fault is not present, an
intermittent concern may be the cause. Always check for loose connections and corroded terminals

Where an 'on demand self-test' is referred to, this can be accessed via the 'diagnostic trouble code monitor' tab
on the manufacturers approved diagnostic system

Check DDW for open campaigns. Refer to the corresponding bulletins and SSMs which may be valid for the
specific customer complaint and carry out the recommendations as required

The table below lists all Diagnostic Trouble Codes (DTCs) that could be logged in the Audio Amplifier Module, for
additional Diagnosis and Testing information refer to the relevant Diagnosis and Testing Section. For additional
information, refer to: Information and Entertainment System (415-00 Information and Entertainment System -
General Information, Diagnosis and Testing).

DTC Description Possible Causes Action


B128A- Speaker #13 - Wiring Refer to electrical circuit diagrams, check left co-axial surround
11 Circuit short harness fault speaker circuits for short to ground. Check speaker for short
to ground Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B128A- Speaker #13 - Wiring Refer to electrical circuit diagrams, check left co-axial surround
12 Circuit short harness fault speaker circuits for short to power. Check speaker for short
to battery Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B128A- Speaker #13 - Wiring Refer to electrical circuit diagrams, check left co-axial surround
13 Circuit open harness fault speaker circuits for open circuit. Check speaker for short
Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B128A- Speaker #13 - Wiring Refer to electrical circuit diagrams, check left co-axial surround
1A Circuit harness fault speaker circuits for short circuit. Check speaker for short
resistance Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
below Audio amplifier module. Refer to the Warranty Policy and Procedures
threshold amplifier manual if a module/component is suspect
fault

B128A- Speaker #13 - Wiring Refer to electrical circuit diagrams, check left co-axial surround
1E Circuit harness fault speaker circuits for open circuit, high resistance, or short
resistance out Speaker fault circuit. Check speaker for short circuit, open circuit. If no
of range Audio harness or speaker fault suspect audio amplifier module. Refer
amplifier to the Warranty Policy and Procedures manual if a
fault module/component is suspect

B128B- Speaker #14 - Wiring Refer to electrical circuit diagrams, check right co-axial
11 Circuit short harness fault surround speaker circuits for short to ground. Check speaker for
to ground Speaker fault short circuit, open circuit. If no harness or speaker fault suspect
Audio audio amplifier module. Refer to the Warranty Policy and
amplifier Procedures manual if a module/component is suspect
fault

B128B- Speaker #14 - Wiring Refer to electrical circuit diagrams, check right co-axial
12 Circuit short harness fault surround speaker circuits for short to power. Check speaker for
to battery Speaker fault short circuit, open circuit. If no harness or speaker fault suspect
Audio audio amplifier module. Refer to the Warranty Policy and
amplifier Procedures manual if a module/component is suspect
fault

B128B- Speaker #14 - Wiring Refer to electrical circuit diagrams, check right co-axial
13 Circuit open harness fault surround speaker circuits for open circuit. Check speaker for
Speaker fault short circuit, open circuit. If no harness or speaker fault suspect
Audio audio amplifier module. Refer to the Warranty Policy and
amplifier Procedures manual if a module/component is suspect
fault

B128B- Speaker #14 - Wiring Refer to electrical circuit diagrams, check right co-axial
1A Circuit harness fault surround speaker circuits for short circuit. Check speaker for
resistance Speaker fault short circuit, open circuit. If no harness or speaker fault suspect
below Audio audio amplifier module. Refer to the Warranty Policy and
threshold amplifier Procedures manual if a module/component is suspect
fault

B128B- Speaker #14 - Wiring Refer to electrical circuit diagrams, check right co-axial
1E Circuit harness fault surround speaker circuits for open circuit, high resistance, or
resistance out Speaker fault short circuit. Check speaker for short circuit, open circuit. If no
of range Audio harness or speaker fault suspect audio amplifier module. Refer
amplifier to the Warranty Policy and Procedures manual if a
fault module/component is suspect

B128C- Speaker #15 - Wiring Refer to electrical circuit diagrams, check front center speaker
11 Circuit short harness fault circuits for short to ground. Check speaker for short circuit,
to ground Speaker fault open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B128C- Speaker #15 - Wiring Refer to electrical circuit diagrams, check front center speaker
12 Circuit short harness fault circuits for short to power. Check speaker for short circuit,
to battery Speaker fault open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B128C- Speaker #15 - Wiring Refer to electrical circuit diagrams, check front center speaker
13 Circuit open harness fault circuits for open circuit. Check speaker for short circuit, open
Speaker fault circuit. If no harness or speaker fault suspect audio amplifier
Audio module. Refer to the Warranty Policy and Procedures manual if
amplifier a module/component is suspect
fault

B128C- Speaker #15 - Wiring Refer to electrical circuit diagrams, check front center speaker
1A Circuit harness fault circuits for short circuit. Check speaker for short circuit, open
resistance Speaker fault circuit. If no harness or speaker fault suspect audio amplifier
below Audio module. Refer to the Warranty Policy and Procedures manual if
threshold amplifier a module/component is suspect
fault

B128C- Speaker #15 - Wiring Refer to electrical circuit diagrams, check front center speaker
1E Circuit harness fault circuits for open circuit, high resistance, or short circuit. Check
resistance out Speaker fault speaker for short circuit, open circuit. If no harness or speaker
of range Audio fault suspect audio amplifier module. Refer to the Warranty
amplifier Policy and Procedures manual if a module/component is
fault suspect

B1A01- Speaker #1 - Wiring Refer to electrical circuit diagrams, on a premium & high line
11 Circuit short harness fault system check left front tweeter circuits, on a low line system
to ground Speaker fault check mid range speaker and tweeter circuits for short to
Audio ground. Check speaker for short circuit, open circuit. if no
amplifier harness or speaker fault suspect audio amplifier module. Refer
fault to the Warranty Policy and Procedures manual if a
module/component is suspect

B1A01- Speaker #1 - Wiring Refer to electrical circuit diagrams, on a premium & high line
12 Circuit short harness fault system check left front tweeter circuits, on a low line system
to battery Speaker fault check mid range speaker and tweeter circuits for short to
Audio power. Check speaker for short circuit, open circuit. if no
amplifier harness or speaker fault suspect audio amplifier module. Refer
fault to the Warranty Policy and Procedures manual if a
module/component is suspect

B1A01- Speaker #1 - Wiring Refer to electrical circuit diagrams, on a premium & high line
13 Circuit open harness fault system check left front tweeter circuits, on a low line system
Speaker fault check mid range speaker and tweeter circuits for open circuit.
Audio Check speaker for short circuit, open circuit. if no harness or
amplifier speaker fault suspect audio amplifier module. Refer to the
fault Warranty Policy and Procedures manual if a
module/component is suspect

B1A01- Speaker #1 - Wiring Refer to electrical circuit diagrams, on a premium & high line
1A Circuit harness fault system check left front tweeter circuits, on a low line system
resistance Speaker fault check mid range speaker and tweeter circuits for short circuit.
below Audio Check speaker for short circuit, open circuit. if no harness or
threshold amplifier speaker fault suspect audio amplifier module. Refer to the
fault Warranty Policy and Procedures manual if a
module/component is suspect

B1A01- Speaker #1 - Wiring Refer to electrical circuit diagrams, on a premium & high line
1E Circuit harness fault system check left front tweeter circuits, on a low line system
resistance out Speaker fault check mid range speaker and tweeter circuits for open circuit,
of range Audio high resistance or short circuit. Check speaker for short circuit,
amplifier open circuit. if no harness or speaker fault suspect audio
fault amplifier module. Refer to the Warranty Policy and Procedures
manual if a module/component is suspect

B1A02- Speaker #2 - Wiring Refer to electrical circuit diagrams, check left front bass
11 Circuit short harness fault speaker circuits for short to ground. Check speaker for short
to ground Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B1A02- Speaker #2 - Wiring Refer to electrical circuit diagrams, check left front bass
12 Circuit short harness fault speaker circuits for short to power. Check speaker for short
to battery Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B1A02- Speaker #2 - Wiring Refer to electrical circuit diagrams, check left front bass
13 Circuit open harness fault speaker circuits for open circuit. Check speaker for short
Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B1A02- Speaker #2 - Wiring Refer to electrical circuit diagrams, check left front bass
1A Circuit harness fault speaker circuits for short circuit. Check speaker for short
resistance Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
below Audio amplifier module. Refer to the Warranty Policy and Procedures
threshold amplifier manual if a module/component is suspect
fault
B1A02- Speaker #2 - Wiring Refer to electrical circuit diagrams, check left front bass
1E Circuit harness fault speaker circuits for open circuit, high resistance, or short
resistance out Speaker fault circuit. Check speaker for short circuit, open circuit. If no
of range Audio harness or speaker fault suspect audio amplifier module. Refer
amplifier to the Warranty Policy and Procedures manual if a
fault module/component is suspect

B1A03- Speaker #3 - Wiring Refer to electrical circuit diagrams, on a premium & high line
11 Circuit short harness fault system check right front tweeter circuits, on a low line system
to ground Speaker fault check mid range speaker and tweeter circuits for short to
Audio ground. Check speaker for short circuit, open circuit. if no
amplifier harness or speaker fault suspect audio amplifier module. Refer
fault to the Warranty Policy and Procedures manual if a
module/component is suspect

B1A03- Speaker #3 - Wiring Refer to electrical circuit diagrams, on a premium & high line
12 Circuit short harness fault system check right front tweeter circuits, on a low line system
to battery Speaker fault check mid range speaker and tweeter circuits for short to
Audio power. Check speaker for short circuit, open circuit. if no
amplifier harness or speaker fault suspect audio amplifier module. Refer
fault to the Warranty Policy and Procedures manual if a
module/component is suspect

B1A03- Speaker #3 - Wiring Refer to electrical circuit diagrams, on a premium & high line
13 Circuit open harness fault system check right front tweeter circuits, on a low line system
Speaker fault check mid range speaker and tweeter circuits for open circuit.
Audio Check speaker for short circuit, open circuit. if no harness or
amplifier speaker fault suspect audio amplifier module. Refer to the
fault Warranty Policy and Procedures manual if a
module/component is suspect

B1A03- Speaker #3 - Wiring Refer to electrical circuit diagrams, on a premium & high line
1A Circuit harness fault system check right front tweeter circuits, on a low line system
resistance Speaker fault check mid range speaker and tweeter circuits for short circuit.
below Audio Check speaker for short circuit, open circuit. if no harness or
threshold amplifier speaker fault suspect audio amplifier module. Refer to the
fault Warranty Policy and Procedures manual if a
module/component is suspect

B1A03- Speaker #3 - Wiring Refer to electrical circuit diagrams, on a premium & high line
1E Circuit harness fault system check right front tweeter circuits, on a low line system
resistance out Speaker fault check mid range speaker and tweeter circuits for open circuit,
of range Audio high resistance or short circuit. Check speaker for short circuit,
amplifier open circuit. if no harness or speaker fault suspect audio
fault amplifier module. Refer to the Warranty Policy and Procedures
manual if a module/component is suspect

B1A04- Speaker #4 - Wiring Refer to electrical circuit diagrams, check right front bass
11 Circuit short harness fault speaker circuits for short to ground. Check speaker for short
to ground Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B1A04- Speaker #4 - Wiring Refer to electrical circuit diagrams, check right front bass
12 Circuit short harness fault speaker circuits for short to power. Check speaker for short
to battery Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B1A04- Speaker #4 - Wiring Refer to electrical circuit diagrams, check right front bass
13 Circuit open harness fault speaker circuits for open circuit. Check speaker for short
Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B1A04- Speaker #4 - Wiring Refer to electrical circuit diagrams, check right front bass
1A Circuit harness fault speaker circuits for short circuit. Check speaker for short
resistance Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
below Audio amplifier module. Refer to the Warranty Policy and Procedures
threshold amplifier manual if a module/component is suspect
fault

B1A04- Speaker #4 - Wiring Refer to electrical circuit diagrams, check right front bass
1E Circuit harness fault speaker circuits for open circuit, high resistance, or short
resistance out Speaker fault circuit. Check speaker for short circuit, open circuit. If no
of range Audio harness or speaker fault suspect audio amplifier module. Refer
amplifier to the Warranty Policy and Procedures manual if a
fault module/component is suspect

B1A05- Speaker #5 - Wiring Refer to electrical circuit diagrams, check left rear tweeter
11 Circuit short harness fault speaker circuits for short to ground. Check speaker for short
to ground Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B1A05- Speaker #5 - Wiring Refer to electrical circuit diagrams, check left rear tweeter
12 Circuit short harness fault speaker circuits for short to power. Check speaker for short
to battery Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B1A05- Speaker #5 - Wiring Refer to electrical circuit diagrams, check left rear tweeter
13 Circuit open harness fault speaker circuits for open circuit. Check speaker for short
Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B1A05- Speaker #5 - Wiring Refer to electrical circuit diagrams, check left rear tweeter
1A Circuit harness fault speaker circuits for short circuit. Check speaker for short
resistance Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
below Audio amplifier module. Refer to the Warranty Policy and Procedures
threshold amplifier manual if a module/component is suspect
fault

B1A05- Speaker #5 - Wiring Refer to electrical circuit diagrams, check left rear tweeter
1E Circuit harness fault speaker circuits for open circuit, high resistance, or short
resistance out Speaker fault circuit. Check speaker for short circuit, open circuit. If no
of range Audio harness or speaker fault suspect audio amplifier module. Refer
amplifier to the Warranty Policy and Procedures manual if a
fault module/component is suspect

B1A06- Speaker #6 - Wiring Refer to electrical circuit diagrams, check left rear bass speaker
11 Circuit short harness fault circuits for short to ground. Check speaker for short circuit,
to ground Speaker fault open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B1A06- Speaker #6 - Wiring Refer to electrical circuit diagrams, check left rear bass speaker
12 Circuit short harness fault circuits for short to power. Check speaker for short circuit,
to battery Speaker fault open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B1A06- Speaker #6 - Wiring Refer to electrical circuit diagrams, check left rear bass speaker
13 Circuit open harness fault circuits for open circuit. Check speaker for short circuit, open
Speaker fault circuit. If no harness or speaker fault suspect audio amplifier
Audio module. Refer to the Warranty Policy and Procedures manual if
amplifier a module/component is suspect
fault

B1A06- Speaker #6 - Wiring Refer to electrical circuit diagrams, check left rear bass speaker
1A Circuit harness fault circuits for short circuit. Check speaker for short circuit, open
resistance Speaker fault circuit. If no harness or speaker fault suspect audio amplifier
below Audio module. Refer to the Warranty Policy and Procedures manual if
threshold amplifier a module/component is suspect
fault

B1A06- Speaker #6 - Wiring Refer to electrical circuit diagrams, check left rear bass speaker
1E Circuit harness fault circuits for open circuit, high resistance, or short circuit. Check
resistance out Speaker fault speaker for short circuit, open circuit. If no harness or speaker
of range Audio fault suspect audio amplifier module. Refer to the Warranty
amplifier Policy and Procedures manual if a module/component is
fault suspect

B1A07- Speaker #7 - Wiring Refer to electrical circuit diagrams, check right rear tweeter
11 Circuit short harness fault speaker circuits for short to ground. Check speaker for short
to ground Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B1A07- Speaker #7 - Wiring Refer to electrical circuit diagrams, check right rear tweeter
12 Circuit short harness fault speaker circuits for short to power. Check speaker for short
to battery Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B1A07- Speaker #7 - Wiring Refer to electrical circuit diagrams, check right rear tweeter
13 Circuit open harness fault speaker circuits for open circuit. Check speaker for short
Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B1A07- Speaker #7 - Wiring Refer to electrical circuit diagrams, check right rear tweeter
1A Circuit harness fault speaker circuits for short circuit. Check speaker for short
resistance Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
below Audio amplifier module. Refer to the Warranty Policy and Procedures
threshold amplifier manual if a module/component is suspect
fault

B1A07- Speaker #7 - Wiring Refer to electrical circuit diagrams, check right rear tweeter
1E Circuit harness fault speaker circuits for open circuit, high resistance, or short
resistance out Speaker fault circuit. Check speaker for short circuit, open circuit. If no
of range Audio harness or speaker fault suspect audio amplifier module. Refer
amplifier to the Warranty Policy and Procedures manual if a
fault module/component is suspect

B1A08- Speaker #8 - Wiring Refer to electrical circuit diagrams, check right rear bass
11 Circuit short harness fault speaker circuits for short to ground. Check speaker for short
to ground Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B1A08- Speaker #8 - Wiring Refer to electrical circuit diagrams, check right rear bass
12 Circuit short harness fault speaker circuits for short to power. Check speaker for short
to battery Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B1A08- Speaker #8 - Wiring Refer to electrical circuit diagrams, check right rear bass
13 Circuit open harness fault speaker circuits for open circuit. Check speaker for short
Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B1A08- Speaker #8 - Wiring Refer to electrical circuit diagrams, check right rear bass
1A Circuit harness fault speaker circuits for short circuit. Check speaker for short
resistance Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
below Audio amplifier module. Refer to the Warranty Policy and Procedures
threshold amplifier manual if a module/component is suspect
fault

B1A08- Speaker #8 - Wiring Refer to electrical circuit diagrams, check right rear bass
1E Circuit harness fault speaker circuits for open circuit, high resistance, or short
resistance out Speaker fault circuit. Check speaker for short circuit, open circuit. If no
of range Audio harness or speaker fault suspect audio amplifier module. Refer
amplifier to the Warranty Policy and Procedures manual if a
fault module/component is suspect

B1A09- Speaker #9 - Wiring Refer to electrical circuit diagrams, check left front mid range
11 Circuit short harness fault speaker circuits for short to ground. Check speaker for short
to ground Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B1A09- Speaker #9 - Wiring Refer to electrical circuit diagrams, check left front mid range
12 Circuit short harness fault speaker circuits for short to power. Check speaker for short
to battery Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B1A09- Speaker #9 - Wiring Refer to electrical circuit diagrams, check left front mid range
13 Circuit open harness fault speaker circuits for open circuit. Check speaker for short
Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B1A09- Speaker #9 - Wiring Refer to electrical circuit diagrams, check left front mid range
1A Circuit harness fault speaker circuits for short circuit. Check speaker for short
resistance Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
below Audio amplifier module. Refer to the Warranty Policy and Procedures
threshold amplifier manual if a module/component is suspect
fault

B1A09- Speaker #9 - Wiring Refer to electrical circuit diagrams, check left front mid range
1E Circuit harness fault speaker circuits for open circuit, high resistance, or short
resistance out Speaker fault circuit. Check speaker for short circuit, open circuit. If no
of range Audio harness or speaker fault suspect audio amplifier module. Refer
amplifier to the Warranty Policy and Procedures manual if a
fault module/component is suspect

B1A10- Speaker #10 - Wiring Refer to electrical circuit diagrams, check right front mid range
11 Circuit short harness fault speaker circuits for short to ground. Check speaker for short
to ground Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B1A10- Speaker #10 - Wiring Refer to electrical circuit diagrams, check right front mid range
12 Circuit short harness fault speaker circuits for short to power. Check speaker for short
to battery Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B1A10- Speaker #10 - Wiring Refer to electrical circuit diagrams, check right front mid range
13 Circuit open harness fault speaker circuits for open circuit. Check speaker for short
Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B1A10- Speaker #10 - Wiring Refer to electrical circuit diagrams, check right front mid range
1A Circuit harness fault speaker circuits for short circuit. Check speaker for short
resistance Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
below Audio amplifier module. Refer to the Warranty Policy and Procedures
threshold amplifier manual if a module/component is suspect
fault

B1A10- Speaker #10 - Wiring Refer to electrical circuit diagrams, check right front mid range
1E Circuit harness fault speaker circuits for open circuit, high resistance, or short
resistance out Speaker fault circuit. Check speaker for short circuit, open circuit. If no
of range Audio harness or speaker fault suspect audio amplifier module. Refer
amplifier to the Warranty Policy and Procedures manual if a
fault module/component is suspect

B1A11- Speaker #11 - Wiring Refer to electrical circuit diagrams, check left sub-woofer
11 Circuit short harness fault speaker circuits for short to ground. Check speaker for short
to ground Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B1A11- Speaker #11 - Wiring Refer to electrical circuit diagrams, check left sub-woofer
12 Circuit short harness fault speaker circuits for short to power. Check speaker for short
to battery Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B1A11- Speaker #11 - Wiring Refer to electrical circuit diagrams, check left sub-woofer
13 Circuit open harness fault speaker circuits for open circuit. Check speaker for short
Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B1A11- Speaker #11 - Wiring Refer to electrical circuit diagrams, check left sub-woofer
1A Circuit harness fault speaker circuits for short circuit. Check speaker for short
resistance Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
below Audio amplifier module. Refer to the Warranty Policy and Procedures
threshold amplifier manual if a module/component is suspect
fault

B1A11- Speaker #11 - Wiring Refer to electrical circuit diagrams, check left sub-woofer
1E Circuit harness fault speaker circuits for open circuit, high resistance, or short
resistance out Speaker fault circuit. Check speaker for short circuit, open circuit. If no
of range Audio harness or speaker fault suspect audio amplifier module. Refer
amplifier to the Warranty Policy and Procedures manual if a
fault module/component is suspect

B1A12- Speaker #12 - Wiring Refer to electrical circuit diagrams, check right sub-woofer
11 Circuit short harness fault speaker circuits for short to ground. Check speaker for short
to ground Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B1A12- Speaker #12 - Wiring Refer to electrical circuit diagrams, check right sub-woofer
12 Circuit short harness fault speaker circuits for short to power. Check speaker for short
to battery Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B1A12- Speaker #12 - Wiring Refer to electrical circuit diagrams, check right sub-woofer
13 Circuit open harness fault speaker circuits for open circuit. Check speaker for short
Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
Audio amplifier module. Refer to the Warranty Policy and Procedures
amplifier manual if a module/component is suspect
fault

B1A12- Speaker #12 - Wiring Refer to electrical circuit diagrams, check right sub-woofer
1A Circuit harness fault speaker circuits for short circuit. Check speaker for short
resistance Speaker fault circuit, open circuit. If no harness or speaker fault suspect audio
below Audio amplifier module. Refer to the Warranty Policy and Procedures
threshold amplifier manual if a module/component is suspect
fault

B1A12- Speaker #12 - Wiring Refer to electrical circuit diagrams, check right sub-woofer
1E Circuit harness fault speaker circuits for open circuit, high resistance, or short
resistance out Speaker fault circuit. Check speaker for short circuit, open circuit. If no
of range Audio harness or speaker fault suspect audio amplifier module. Refer
amplifier to the Warranty Policy and Procedures manual if a
fault module/component is suspect

B1297- Digital Wiring NOTE:


01 Headphone harness fault
Module - Infra-red Applies to vehicles with Digital wireless headphones installed only
General headphone
Electrical transmitter Refer to electrical circuit diagrams and check data signal
Failure module fault circuits between the audio amplifier and the infra-red
Audio transmitter module for short circuit. Confirm power and ground
amplifier supplies are present at the module. Repair wiring harness as
fault required. Clear DTC and retest system. If fault resets suspect
(1) infra-red transmitter module, (2) audio amplifier module.
Refer to the Warranty Policy and Procedures manual if a
module/component is suspect

B1297- Digital Wiring NOTE:


13 Headphone harness fault
Module - Infra-red Applies to vehicles with Digital wireless headphones installed only
Circuit open headphone
transmitter Refer to electrical circuit diagrams and check data signal
module fault circuits between the audio amplifier and the infra-red
Audio transmitter module for open circuit. Confirm power and ground
amplifier supplies are present at the module. Repair wiring harness as
fault required. Clear DTC and retest system. If fault resets suspect
(1) infra-red transmitter module, (2) audio amplifier module.
Refer to the Warranty Policy and Procedures manual if a
module/component is suspect

U2300- Central Configuration Check/amend the car configuration file using the manufacturer
54 Configuration missing approved diagnostic system
- Missing
calibration
U2300- Central Vehicle Check the vehicle is configured correctly using the
56 Configuration configuration manufacturer approved diagnostic system
- Invalid / file error
incomplete
configuration
U2300- Central Configuration Check the components installed to the vehicle are correct (not
64 Configuration file error substituted from another vehicle). Install the original or a new
- Signal Substituted component as required. This DTC will occur once if a new
plausibility component module is installed. Clear the DTC, cycle the ignition state to
failure New (blank) off. Lock the vehicle (to ensure the infotainment system has
component reset). Unlock the vehicle, cycle the ignition state to on. Retest
the system

U3000- Control Configuration The local configuration file has not been programmed into the
55 Module - Not file error audio amplifier. Programme the audio amplifier with the
configured correct file using the manufacturer approved diagnostic system

U3000- Control Audio Check power and ground supplies to the Audio Amplifier
96 Module - amplifier Module. If no fault found suspect internal fault within audio
Component internal fault amplifier module. Clear DTCs and run Amplifier On Demand
internal Self Test. Refer to the Warranty Policy and Procedures manual
failure if a module/component is suspect

U3000- Control Audio Check for possible causes of the amplifier overheating. Check
98 Module - amplifier that the amplifier module ventilation is not obstructed (rear left
Component cooling vents quarter of luggage compartment). Check for speaker circuit
or system obstructed related DTCs. Check for internal electronic failure related
over Speaker DTCs. Refer to the Warranty Policy and Procedures manual if a
temperature circuit fault module/component is suspect
Internal
electronic
failure
Published: 17-Apr-2014

2012.0 XF (X250), 100-00

General Information

Diagnostic Trouble Code Index - DTC: Blind Spot


Monitoring System Module (SODL/SODR) (G1426777)
DESCRIPTION AND OPERATION
Blind Spot Monitoring System Module (SODL/SODR)
CAUTION:

Diagnosis by substitution from a donor vehicle is NOT acceptable. Substitution of control modules does not
guarantee confirmation of a fault and may also cause additional faults in the vehicle being checked and/or the donor
vehicle.

NOTES:

If the control module or a component is suspect and the vehicle remains under manufacturer warranty, refer to
the Warranty Policy and Procedures manual, or determine if any prior approval programme is in operation,
prior to the installation of a new module/component.

Generic scan tools may not read the codes listed, or may read only 5-digit codes. Match the 5 digits from the
scan tool to the first 5 digits of the 7-digit code listed to identify the fault (the last 2 digits give extra
information read by the manufacturer approved diagnostic system).

When performing voltage or resistance tests, always use a digital multimeter (DMM) accurate to three decimal
places, and with an up-to-date calibration certificate. When testing resistance, always take the resistance of the
DMM leads into account.

Check and rectify basic faults before beginning diagnostic routines involving pinpoint tests.

If DTCs are recorded and, after performing the pinpoint tests a fault is not present, an intermittent concern
may be the cause. Always check for loose connections and corroded terminals.

Where an 'on demand self-test' is referred to, this can be accessed via the 'DTC Monitor' tab on the
manufacturers approved diagnostic system.

Check DDW for open campaigns. Refer to the corresponding bulletins and SSMs which may be valid for the
specific customer complaint and carry out the recommendations as required.

The table below lists all Diagnostic Trouble Codes (DTCs) that could be logged in the Blind Spot Monitoring
System Module, for additional Diagnosis and Testing information refer to the relevant Diagnosis and Testing
Section. For additional information, refer to: Warning Devices (413-09 Warning Devices, Diagnosis and Testing).

DTC Description Possible Causes Action


B11C9- Driver Display Circuit short to Refer to the electrical circuit diagrams and check driver
11 Status LED - ground display status LED circuit for short to ground
Circuit short to
ground
B11C9- Driver Display Circuit short to Refer to the electrical circuit diagrams and check driver
15 Status LED - power or open display status LED circuit for short to ground
Circuit short to circuit
battery or open
B11D6- Driver Display Circuit short to Refer to the electrical circuit diagrams and check driver
11 Alert LED - ground display status LED circuit for short to ground
Circuit short to
ground
B11D6- Driver Display Circuit short to Refer to the electrical circuit diagrams and check driver
15 Alert LED - power or open display status LED circuit for short to ground
Circuit short to circuit
battery or open
U0010- Medium Speed No sub type Refer to the electrical circuit diagrams and check the
00 CAN information power and ground connections to the module. Using the
Communication manufacturer approved diagnostic system, complete a
Bus - No sub CAN network integrity test. Refer to the electrical circuit
type information diagrams and check the CAN network

U0140- Lost No sub type Refer to the electrical circuit diagrams and check the
00 Communication information power and ground connections to the module. Using the
With Body manufacturer approved diagnostic system, complete a
Control Module CAN network integrity test. Refer to the electrical circuit
- No sub type diagrams and check the CAN network between the
information Central Junction Box and Blind Spot Monitoring System
Module

U0155- Lost No sub type Refer to the electrical circuit diagrams and check the
00 Communication information power and ground connections to the module. Using the
With Instrument manufacturer approved diagnostic system, complete a
Panel Cluster CAN network integrity test. Refer to the electrical circuit
(IPC) Control diagrams and check the CAN network between the
Module - No sub Instrument Cluster and Blind Spot Monitoring System
type information Module

U0232- Lost CAN bus circuit Refer to the electrical circuit diagrams and check the
00 Communication fault power and ground connections to the module. Using the
With Blind Spot Harness fault manufacturer approved diagnostic system, complete a
Monitoring between left CAN network integrity test. Refer to the electrical circuit
System Module side mirror and diagrams and check the CAN network between the left
- Left - No sub left side module Blind Spot Monitoring System Module and the right
type information Blind Spot Monitoring System Module
Refer to the electrical circuit diagrams and check the left
side harness between the left side mirror and left hand
module

U0233- Lost CAN bus circuit Refer to the electrical circuit diagrams and check the
00 Communication fault power and ground connections to the module. Using the
With Blind Spot Harness fault manufacturer approved diagnostic system, complete a
Monitoring between right CAN network integrity test. Refer to the electrical circuit
System Module side mirror and diagrams and check the CAN network between the left
- Right - No sub right side Blind Spot Monitoring System Module and the right
type information module Blind Spot Monitoring System Module
Refer to the electrical circuit diagrams and check the right
side harness between the right side mirror and right hand
module

U0300- Internal Control No sub type Check Central Junction Box for related DTCs and refer to
00 Module information the relevant DTC Index. Check Restraints Control
Software Module for related DTCs and refer to DTC Index. Check
Incompatibility - correct components are installed and that the latest
No sub type software version is installed
information
U0415- Invalid Data Event Using the manufacturer approved diagnostic system check
68 Received From information the central junction box and the anti-lock brake system
Anti-Lock Brake (ABS) control module for related DTCs and refer to the
System (ABS) relevant DTC Index
Control Module
- event
information
U0422- Invalid Data Event Check the Central Junction Box for related DTCs and
68 Received From information refer to the relevant DTC index
Body Control
Module - Event
information
U2100- Initial Car Check/amend Car Configuration File using manufacturer
00 Configuration Configuration approved diagnostic system
Not Complete - File information
No sub type not received
information completely

U2101- Control Module Car Check/amend Car Configuration File using manufacturer
00 Configuration Configuration approved diagnostic system
Incompatible - File information
No sub type incompatible to
information Control module

U3000- Control Module Control module Refer to the electrical circuit diagrams and check the
44 - Data memory data memory power and ground circuits to the component. Refer to the
failure failure warranty policy and procedures manual if a module is
suspect

U3000- Control Module Control module Refer to the electrical circuit diagrams and check the
47 - internal power and ground circuits to the component. Refer to the
Watchdog/safety watchdog/safety warranty policy and procedures manual if a module is
microcontroller MicroController suspect
failure failure

U3000- Control Module Control module Clear DTC, cycle ignition and retest. If fault persists, refer
49 - Internal internal to the electrical circuit diagrams and check the power and
electronic failure electronic ground circuits to the component. Repair as required,
failure (internal clear DTC and retest
error) If fault persists, check and install a new blindspot
monitoring control module as required. Refer to the
warranty policy and procedures manual if a module is
suspect

U3003- Battery Voltage Mis-match in Check the module connector for security and integrity.
62 - Signal compare battery voltage, Refer to the electrical circuit diagrams and check the
failure between Central Control module supply voltage. Check vehicle battery
Junction Box voltage and state of charge. Check the power signal line to
and Blind Spot the module
Monitoring
System module,
of 2 volts or
more
Published: 17-Apr-2014

2012.0 XF (X250), 100-00

General Information

Diagnostic Trouble Code Index - DTC: Central


Junction Box (CJB) (G1426778)
DESCRIPTION AND OPERATION
Central Junction Box (CJB)
CAUTION:

Diagnosis by substitution from a donor vehicle is NOT acceptable. Substitution of control modules does not
guarantee confirmation of a fault, and may also cause additional faults in the vehicle being tested and/or the donor
vehicle

NOTES:

If the control module or a component is suspect and the vehicle remains under manufacturer warranty, refer to
the warranty policy and procedures manual, or determine if any prior approval programme is in operation,
prior to the installation of a new module/component

Generic scan tools may not read the codes listed, or may read only 5-digit codes. Match the 5 digits from the
scan tool to the first 5 digits of the 7-digit code listed to identify the fault (the last 2 digits give extra
information read by the manufacturer-approved diagnostic system)

When performing voltage or resistance tests, always use a digital multimeter accurate to three decimal places
and with a current calibration certificate. When testing resistance, always take the resistance of the digital
multimeter leads into account

Check and rectify basic faults before beginning diagnostic routines involving pinpoint tests

Inspect connectors for signs of water ingress, and pins for damage and/or corrosion

If diagnostic trouble codes are recorded and, after performing the pinpoint tests, a fault is not present, an
intermittent concern may be the cause. Always check for loose connections and corroded terminals

Where an 'on demand self-test' is referred to, this can be accessed via the 'diagnostic trouble code monitor' tab
on the manufacturers approved diagnostic system

Check DDW for open campaigns. Refer to the corresponding bulletins and SSMs which may be valid for the
specific customer complaint and carry out the recommendations as required

The table below lists all diagnostic trouble codes (DTCs) that could be logged in the central junction box, for
additional diagnosis and testing information refer to the relevant diagnosis and testing section.For additional
information, refer to: Communications Network (418-00 Module Communications Network, Diagnosis and
Testing).

DTC Description Possible Causes Action


B00D5- Restraint System Passenger airbag disabled lamp Refer to the electrical circuit
11 Passenger Disable supply circuit - short circuit to diagrams and check passenger
Indicator - Circuit ground airbag disabled lamp supply circuit
short to ground for short circuit to ground. Repair
wiring harness as required, clear the
DTC and retest the system

B1009- Ignition NOTE: Check ignition, power and ground


51 Authorization - supplies to central junction box and
Not programmed This DTC is only likely to occur instrument cluster
following component replacement Re-synchronize ID by re-
applications failing prior to completion configuring the instrument cluster
as a new module
Faulty instrument cluster Using the manufacturer approved
Target SID re-synchronisation error diagnostic system, complete a CAN
following programming network integrity test. Refer to the
CAN fault electrical circuit diagrams and
check the CAN network between
the central junction box and
instrument cluster

B1009- Ignition NOTE: Refer to the electrical circuit


62 Authorization - diagrams and check the power and
Signal compare This DTC is only likely to occur ground connections to the central
failure following component replacement junction box and instrument cluster
applications failing prior to completion Using the manufacturer approved
diagnostic system, complete a CAN
Central junction box fault network integrity test. Refer to the
Instrument cluster fault electrical circuit diagrams and
Low speed CAN fault check the CAN network between
Incorrect module installed (central the central junction box and
junction box/instrument cluster) instrument cluster
Re-synchronisation error following Confirm correct central junction
re-programming box/instrument cluster module is
installed
Re-synchronise ID by re-
configuring the instrument cluster
as a new module. Clear DTC and
retest
Check CAN network for
interference/electromagnetic
compatibility related issues. Ensure
that the vehicle is away from
sources of electromagnetic
interference prior to clearing DTCs
and retesting

B1009- Ignition Circuit/component protection time- NOTE:


63 Authorization - out
Circuit/component CAN circuit fault Only diagnose this DTC if the customer is
protection time- Instrument cluster fault reporting a start related issue
out Central junction box fault
Battery voltage too low Clear the DTC and retest. Check for
additional ignition related DTCs
and rectify as necessary. If problem
persists, carry out CAN network
integrity test and on demand self
test using manufacturer approved
diagnostic system. Alternatively,
refer to the electrical circuit
diagrams and check CAN circuits
B1009- Ignition Central junction box fault Refer to the electrical circuit
64 Authorisation - Low speed CAN fault diagrams and check the power and
Signal plausibility Instrument cluster fault ground connections to the central
failure junction box and instrument cluster
Using the manufacturer approved
diagnostic system, complete a CAN
network integrity test. Refer to the
electrical circuit diagrams and
check the CAN network between
the central junction box and
instrument cluster

B102B- Passive Key - NOTE: Refer to the electrical circuit


67 Signal incorrect diagrams and check the power and
after event This DTC is only likely to occur ground connections to the central
following component replacement junction box and the remote keyless
applications failing prior to completion entry module
Using the manufacturer approved
Central junction box fault diagnostic system, complete a CAN
Remote keyless entry module fault network integrity test. Refer to the
Low speed CAN fault electrical circuit diagrams and
Encrypted data exchange between check the CAN network between
remote keyless entry module and the central junction box and remote
central junction box does not match keyless entry module
Re-synchronise ID by re-
configuring the central junction box
as a new module. Clear DTC and
retest
Re-synchronise ID by re-
configuring the remote keyless
entry module as a new module.
Clear DTC and retest

B102B- Passive Key - Passive key authorization missing Check whereabouts of keys,
87 Missing message message including spare and confirm correct
Confirm placement of key within functionality
vehicle Refer to the electrical circuit
Low speed CAN fault diagrams and check the power and
Key fob battery low/battery contact ground connections to the central
issue junction box and the remote keyless
Interference from other RF signal entry module
Remote keyless entry module fault Using the manufacturer approved
Receiver fault diagnostic system, complete a CAN
Receiver not programmed correctly network integrity test. Refer to the
Serial communication fault electrical circuit diagrams and
(between receiver and keyless check the CAN network between
vehicle module) the central junction box and remote
Key fault keyless entry module
Passive antenna(s) fault Check key fob battery
Central junction box fault Check CAN network for
interference/electromagnetic
compatibility related issues. Check
vehicle surroundings for possible
sources of interference, move
vehicle and retest
Check serial data circuit between
receiver and keyless vehicle module
Refer to the electrical circuit
diagrams and check circuits to all
three antennas. Disconnect battery,
then re-connect - confirm correct
operation by re-programming keys
using the manufacturer approved
diagnostic system

B1084- Boot/Trunk Motor NOTE: Refer to the electrical circuit


13 Close Switch - diagrams and check the boot open
Circuit open This DTC will only set following the signal circuit for open circuit, high
completion of an on demand test routine resistance
(routine 0202h) If no circuit faults are present,
check and install new switch as
Boot open signal circuit - open required. Clear DTC and retest
circuit, high resistance
Switch fault

B108A- Start Button - Start/stop switch analogue input Refer to the electrical circuit
11 Circuit short to circuits 1 or 2 - short circuit to diagrams and check start/stop
ground ground switch analogue input circuits 1 and
Switch fault 2 for short circuit to ground. Repair
wiring harness as required, clear the
DTC and retest the system
If no circuit faults are present,
check and install new transmission
shift module as required. Clear
DTC and retest
Refer to the warranty policy and
procedures manual, or determine if
any prior approval programme is in
operation, prior to the installation of
a new module/component

B108A- Start Button - Start/stop switch analogue input Refer to the electrical circuit
12 Circuit short to circuits 1 or 2 - short circuit to diagrams and check start/stop
battery power switch analogue input circuits 1 and
Switch fault 2 for short circuit to power. Repair
wiring harness as required, clear the
DTC and retest the system
If no circuit faults are present,
check and install new transmission
shift module as required. Clear
DTC and retest
Refer to the warranty policy and
procedures manual, or determine if
any prior approval programme is in
operation, prior to the installation of
a new module/component

B108A- Start Button - Start/stop switch analogue input Refer to the electrical circuit
13 Circuit open circuits 1 or 2 - open circuit, high diagrams and check start/stop
resistance switch analogue input circuits 1 and
Switch fault 2 for open circuit, high resistance.
Repair wiring harness as required,
clear the DTC and retest the system
If no circuit faults are present,
check and install new transmission
shift module as required. Clear
DTC and retest
Refer to the warranty policy and
procedures manual, or determine if
any prior approval programme is in
operation, prior to the installation of
a new module/component

B108A- Start Button - Start button signal stuck low Check the operation of the start
23 Signal stuck low Switch activated for more than 30 button and renew as required
seconds Refer to the electrical circuit
SW1 constantly active for a long diagrams and check start/stop
period of time while button press switch analogue input circuits 1 and
detected at SW2 2. Clear DTC and retest
Switch fault If no circuit faults are present,
check and install new transmission
shift module as required. Clear
DTC and retest
Refer to the warranty policy and
procedures manual, or determine if
any prior approval programme is in
operation, prior to the installation of
a new module/component

B1095- Wiper On/Off Wiper on/off relay control circuit - Refer to the electrical circuit
12 Relay - Circuit short circuit to power diagrams and check wiper on/off
short to battery Wiper run/park relay fault relay control circuit for short
circuit, to power. Repair wiring
harness as required, clear the DTC
and retest the system
If no wiring faults are present,
check and install new wiper
run/park relay as required. Clear
DTC and retest

B1096- Wiper High/Low Wiper fast/slow relay control circuit Refer to the electrical circuit
12 Relay - Circuit - short circuit to power diagrams and check wiper fast/slow
short to battery Wiper hi/low relay fault relay control circuit for short
circuit, to power. Repair wiring
harness as required, clear the DTC
and retest the system
If no wiring faults are present,
check and install new wiper hi/low
relay as required. Clear DTC and
retest

B1097- Heated Heated front screen telltale does not Refer to the electrical circuit
12 Windshield Relay illuminate diagrams and check heated front
- Circuit short to Heated front screen relay control screen relay control circuit for short
battery circuit - short circuit to power circuit, to power. Repair wiring
Front screen heater relay fault harness as required, clear the DTC
and retest the system
If no wiring faults are present,
check and install new right-side
and/or left-side front screen heater
relay as required. Clear DTC and
retest

B10A6- Main Light Switch Master light switch signal from roof Refer to the electrical circuit
13 - Circuit open header console circuit - open diagrams and check master light
circuit, high resistance switch signal from roof header
Switch fault console circuit for open circuit,
high resistance
If no circuit faults are present,
check and install new switch as
required. Clear DTC and retest

B10A6- Main Light Switch Master light switch signal from roof Check the operation of the master
23 - Signal stuck low header console signal stuck low. light switch and renew as required
Switch is read as ON for too long a Refer to the electrical circuit
time diagrams and check master light
Switch fault switch signal from roof header
console circuit. Clear DTC and
retest

B10AD- Rain Sensor - Rain sensor/ambient light sensor Check the rain/ambient light sensor
09 Component obscured is not obscured
failures Battery supply voltage below 9 Check for related low voltage
Volts stored DTCs
Sensor incorrectly installed Check the security and installation
Component failure of the rain/ambient light sensor
Clear the DTC and retest. If the
problem persists, renew the
rain/ambient light sensor
Refer to the warranty policy and
procedures manual, or determine if
any prior approval programme is in
operation, prior to the installation of
a new module/component

B10AD- Rain Sensor - Rain sensor power circuit - short Refer to the electrical circuit
11 Circuit short to circuit to ground diagrams and check rain sensor
ground Component failure power circuit for short circuit to
ground
Clear the DTC and retest. If the
problem persists, renew the
rain/ambient light sensor
Refer to the warranty policy and
procedures manual, or determine if
any prior approval programme is in
operation, prior to the installation of
a new module/component

B10AD- Rain Sensor - Component internal failure Clear the DTC and retest. If the
96 Component problem persists, renew the
internal failure rain/ambient light sensor
Refer to the warranty policy and
procedures manual, or determine if
any prior approval programme is in
operation, prior to the installation of
a new module/component

B10E5- PCM Wake-Up Engine management system engine Refer to the electrical circuit
11 Signal - Circuit wake-up signal circuit - short circuit diagrams and check the engine
short to ground to ground management system engine wake-
up signal circuit for short circuit to
ground. Repair wiring harness as
required, clear the DTC and retest
the system

B10F2- Sunroof Control - Sunroof enable signal circuit - short Refer to the electrical circuit
11 Circuit short to circuit to ground diagrams and check the sunroof
ground enable signal circuit for short
circuit to ground. Repair wiring
harness as required, clear the DTC
and retest the system

B10F3- Left Front Left front side lamps circuit - short Refer to the electrical circuit
11 Position Light - circuit to ground diagrams and check the left front
Circuit short to side lamps circuit for short circuit
ground to ground. Repair wiring harness as
required, clear the DTC and retest
the system

B10F4- Right Front Right front side lamps circuit - short Refer to the electrical circuit
11 Position Light - circuit to ground diagrams and check the right front
Circuit short to side lamps circuit for short circuit
ground to ground. Repair wiring harness as
required, clear the DTC and retest
the system

B10F8- Accessory socket Cigar lighter relay control circuit - Refer to the electrical circuit
11 'A' relay - Circuit short circuit to ground diagrams and check the cigar
short to ground Cigar lighter relay fault lighter relay control circuit for short
circuit to ground. Repair wiring
harness as required, clear the DTC
and retest the system
If no wiring faults are present,
check and install new cigar lighter
relay as required. Clear DTC and
retest

B10F9- Accessory socket Front powerpoint power supply Refer to the electrical circuit
11 'B' relay - Circuit circuit - short circuit to ground diagrams and check the front
short to ground Powerpoint socket fault powerpoint power supply circuit for
short circuit to ground. Repair
wiring harness as required, clear the
DTC and retest the system
If no wiring faults are present,
check and install new socket as
required. Clear DTC and retest

B10FF- Ignition control - Engine junction box ignition relay Refer to the electrical circuit
11 Circuit short to control circuits - Circuit diagrams and check the engine
ground FPDB_IGNITION_CTRL - Short junction box ignition relay control
circuit to ground circuits - Circuit
FPDB_IGNITION_CTRL - For
short circuit to ground. Repair
wiring harness as required, clear the
DTC and retest the system

B10FF- Ignition control - Engine junction box ignition relay Refer to the electrical circuit
15 Circuit short to control circuits - Circuit diagrams and check the engine
battery or open FPDB_IGNITION_CTRL - Short junction box ignition relay control
circuit to power, open circuit, high circuits - Circuit
resistance FPDB_IGNITION_CTRL - For
short circuit to power, open circuit,
high resistance. Repair wiring
harness as required, clear the DTC
and retest the system

B1100- O2 sensor heater Upstream heated exhaust gas Refer to the electrical circuit
11 relay - Circuit oxygen sensor relay control circuit - diagrams and check the upstream
short to ground Circuit UHEGO_RLY_CTRL - heated exhaust gas oxygen sensor
Short circuit to ground relay control circuit - Circuit
Heated exhaust gas oxygen sensor UHEGO_RLY_CTRL - For short
relay fault circuit to ground
If no wiring faults are present,
check and install new upstream
heated exhaust gas oxygen sensor
relay as required. Clear DTC and
retest

B1100- O2 sensor heater Upstream heated exhaust gas Refer to the electrical circuit
15 relay - Circuit oxygen sensor relay control circuit - diagrams and check the upstream
short to battery or Circuit UHEGO_RLY_CTRL - heated exhaust gas oxygen sensor
open Short circuit to power, open circuit, relay control circuit - Circuit
high resistance UHEGO_RLY_CTRL - For short
Heated exhaust gas oxygen sensor circuit to power, open circuit, high
relay fault resistance
If no wiring faults are present,
check and install new upstream
heated exhaust gas oxygen sensor
relay as required. Clear DTC and
retest

B113D- Sunroof Global Roof opening panel open/close Refer to the electrical circuit
12 Open/Close control circuit - short circuit to diagrams and check the roof
Control - Circuit power opening panel open/close control
short to battery Roof opening panel control module circuit for short circuit to power.
fault Repair wiring harness as required,
clear the DTC and retest the system
If no wiring faults are present,
check and install new roof opening
panel control module as required.
Clear DTC and retest
Refer to the warranty policy and
procedures manual, or determine if
any prior approval programme is in
operation, prior to the installation of
a new module/component
B1140- Engine Crank Engine crank authorisation signal Refer to the electrical circuit
11 Authorisation - circuit - short circuit to ground diagrams and check the engine
Circuit short to Engine control module fault crank authorisation signal circuit
ground for short circuit to ground. Repair
wiring harness as required, clear the
DTC and retest the system
If no wiring faults are present,
check engine control module for
related DTCs and refer to the
relevant DTC index

B1142- Ignition Status 1 - Ignition supply 1 circuit to the Refer to the electrical circuit
11 Circuit short to speed control sensor - Circuit diagrams and check the ignition
ground IGN_SUPPLY_1_FWD - Short supply 1 circuit to the speed control
circuit to ground sensor - Circuit
Speed control module fault IGN_SUPPLY_1_FWD - For short
circuit to ground. Repair wiring
harness as required, clear the DTC
and retest the system
If no wiring faults are present,
check speed control module for
related DTCs and refer to the
relevant DTC index

B1143- Ignition Status 2 - Ignition supply 2 circuit - Circuit Refer to the electrical circuit
11 Circuit short to IGN_SUPPLY_2_FWD - Short diagrams and check the ignition
ground circuit to ground supply 1 circuit - Circuit
Transmission shift module fault IGN_SUPPLY_2_FWD - For short
Transmission control module fault circuit to ground. Repair wiring
Steering angle sensor fault harness as required, clear the DTC
Yaw rate sensor fault and retest the system
ABS module fault If no wiring faults are present,
Engine control module fault check transmission shift module,
transmission control module,
steering angle sensor, yaw rate
sensor, ABS module, engine control
module for related DTCs and refer
to the relevant DTC index

B1144- Heated Steering Heated steering wheel supply Refer to the electrical circuit
11 Wheel Supply - circuit - short circuit to ground diagrams and check the heated
Circuit short to Slip ring fault steering wheel supply circuit for
ground short circuit to ground. Repair
wiring harness as required, clear the
DTC and retest the system
If no wiring faults are present,
check and install new steering
wheel slip ring assembly as
required. Clear DTC and retest

B1144- Heated Steering Heated steering wheel supply Refer to the electrical circuit
15 Wheel Supply - circuit - short circuit to power, open diagrams and check the heated
Circuit short to circuit, high resistance steering wheel supply circuit for
battery or open Slip ring fault short circuit to power, open circuit,
high resistance. Repair wiring
harness as required, clear the DTC
and retest the system
If no wiring faults are present,
check and install new steering
wheel slip ring assembly as
required. Clear DTC and retest

B1145- Glovebox Locking Glovebox latch locking motor Refer to the electrical circuit
11 Motor - Circuit circuit - short circuit to ground diagrams and check the glovebox
short to ground Latch locking motor fault latch locking motor circuit for short
circuit to ground. Repair wiring
harness as required, clear the DTC
and retest the system
If no wiring faults are present,
check and install new latch locking
motor as required. Clear DTC and
retest

B1145- Glovebox Locking Glovebox latch locking motor Refer to the electrical circuit
15 Motor - Circuit circuit - short circuit to power, open diagrams and check the glovebox
short to battery or circuit, high resistance latch locking motor circuit for short
open Latch locking motor fault circuit to power, open circuit, high
resistance. Repair wiring harness as
required, clear the DTC and retest
the system
If no wiring faults are present,
check and install new latch locking
motor as required. Clear DTC and
retest

B1146- Passive sounder Security passive sounder control Refer to the electrical circuit
11 Supply - Circuit circuit - short circuit to ground diagrams and check the security
short to ground Sounder fault passive sounder control circuit for
short circuit to ground. Repair
wiring harness as required, clear the
DTC and retest the system
If no wiring faults are present,
check and install new passive
sounder as required. Clear DTC and
retest

B1146- Passive sounder Security passive sounder control Refer to the electrical circuit
15 Supply - Circuit circuit - short circuit to power, open diagrams and check the security
short to battery or circuit, high resistance passive sounder control circuit for
power Sounder fault short circuit to power, open circuit,
high resistance. Repair wiring
harness as required, clear the DTC
and retest the system
If no wiring faults are present,
check and install new passive
sounder as required. Clear DTC and
retest

B1158- Front Passenger Front passenger seat heater sensor Refer to the electrical circuit
11 Seat Heater circuit - short circuit to ground diagrams and check the front
Sensor - Circuit Sensor fault passenger seat heater sensor circuit
short to ground for short circuit to ground. Repair
wiring harness as required, clear the
DTC and retest the system
If no wiring faults are present,
check and install new front
passenger seat thermal sensor as
required. Clear DTC and retest

B1158- Front Passenger Front passenger seat heater sensor Refer to the electrical circuit
15 Seat Heater circuit - short circuit to power, open diagrams and check the front
Sensor - Circuit circuit, high resistance passenger seat heater sensor circuit
short to battery or Sensor fault for short circuit to power, open
open circuit, high resistance. Repair
wiring harness as required, clear the
DTC and retest the system
If no wiring faults are present,
check and install new front
passenger seat thermal sensor as
required. Clear DTC and retest

B1159- Front Driver Seat Front driver seat heater sensor Refer to the electrical circuit
11 Heater Sensor - circuit - short circuit to ground diagrams and check the front driver
Circuit short to Sensor fault seat heater sensor circuit for short
ground circuit to ground. Repair wiring
harness as required, clear the DTC
and retest the system
If no wiring faults are present,
check and install new front driver
seat thermal sensor as required.
Clear DTC and retest

B1159- Front Driver Seat Front driver seat heater sensor Refer to the electrical circuit
15 Heater Sensor - circuit - short circuit to power, open diagrams and check the front driver
Circuit short to circuit, high resistance seat heater sensor circuit for short
battery or open Sensor fault circuit to power, open circuit, high
resistance. Repair wiring harness as
required, clear the DTC and retest
the system
If no wiring faults are present,
check and install new front driver
seat thermal sensor as required.
Clear DTC and retest

B115A- Front Passenger Front passenger seat heater supply Refer to the electrical circuit
11 Seat Heater - circuit - short circuit to ground diagrams and check the front
Circuit short to Heater element fault passenger seat heater supply circuit
ground for short circuit to ground. Repair
wiring harness as required, clear the
DTC and retest the system
If no wiring faults are present,
check and install new seat
cushion/backrest heater as required.
Clear DTC and retest

B115A- Front Passenger Front passenger seat heater supply Refer to the electrical circuit
15 Seat Heater - circuit - short circuit to power, open diagrams and check the front
Circuit short to circuit, high resistance passenger seat heater supply circuit
battery or open Heater element fault for short circuit to power, open
circuit, high resistance. Repair
wiring harness as required, clear the
DTC and retest the system
If no wiring faults are present,
check and install new seat
cushion/backrest heater as required.
Clear DTC and retest

B115B- Front Driver Seat Front driver seat heater supply Refer to the electrical circuit
11 Heater - Circuit circuit - short circuit to ground diagrams and check the front driver
short to ground Heater element fault seat heater supply circuit for short
circuit to ground. Repair wiring
harness as required, clear the DTC
and retest the system
If no wiring faults are present,
check and install new seat
cushion/backrest heater as required.
Clear DTC and retest

B115B- Front Driver Seat Front driver seat heater supply Refer to the electrical circuit
15 Heater - Circuit circuit - short circuit to power, open diagrams and check the front driver
short to battery or circuit, high resistance seat heater supply circuit for short
open Heater element fault circuit to power, open circuit, high
resistance. Repair wiring harness as
required, clear the DTC and retest
the system
If no wiring faults are present,
check and install new seat
cushion/backrest heater as required.
Clear DTC and retest

B1175- Driver Door Ajar NOTE: Refer to the electrical circuit


13 Switch - Circuit diagrams and check the driver door
open This DTC will only set following the ajar switch signal circuit for open
completion of an on demand test routine circuit, high resistance. Repair
(routine 0202h) wiring harness as required, clear the
DTC and retest the system
Driver door ajar switch signal If no wiring faults are present,
circuit - open circuit, high check and install new door ajar
resistance switch as required. Clear DTC and
Switch fault retest

B1176- Passenger Door NOTE: Refer to the electrical circuit


13 Ajar Switch - diagrams and check the passenger
Circuit open This DTC will only set following the door ajar switch signal circuit for
completion of an on demand test routine open circuit, high resistance. Repair
(routine 0202h) if the circuit is open wiring harness as required, clear the
DTC and retest the system
Passenger door ajar switch signal If no wiring faults are present,
circuit - open circuit, high check and install new door ajar
resistance switch as required. Clear DTC and
Switch fault retest

B1177- Screenwash Level NOTE: Refer to the electrical circuit


13 Switch - Circuit diagrams and check the screenwash
open This DTC will only set following the level switch signal circuit for open
completion of an on demand test routine circuit, high resistance. Repair
(routine 0202h) if the circuit is open wiring harness as required, clear the
DTC and retest the system
Screenwash level switch signal If no wiring faults are present,
circuit - open circuit, high check and install new screenwash
resistance level switch as required. Clear DTC
Switch fault and retest

B1184- Steering Column Steering column locking module Refer to the electrical circuit
11 Lock Output - power circuit - Circuit SCL_PWR - diagrams and check the steering
Circuit short to Short circuit to ground column locking module power
ground circuit - Circuit SCL_PWR - For
short circuit to ground. Repair
wiring harness as required, clear the
DTC and retest the system

B1184- Steering Column Steering column locking module Refer to the electrical circuit
15 Lock Output - power circuit - Circuit SCL_PWR - diagrams and check the steering
Circuit short to Short circuit to power, open circuit, column locking module power
battery or open high resistance circuit - Circuit SCL_PWR - For
short circuit to power, open circuit,
high resistance. Repair wiring
harness as required, clear the DTC
and retest the system

B11C1- Passenger Side NOTE: Refer to the electrical circuit


13 Rear Door Ajar diagrams and check the right side
Switch - Circuit This DTC will only set following the rear door ajar switch signal circuit
open completion of an on demand test routine for open circuit, high resistance.
(routine 0202h) if the circuit is open Repair wiring harness as required,
clear the DTC and retest the system
Right side rear door ajar switch If no wiring faults are present,
signal circuit - open circuit, high check and install new door ajar
resistance switch as required. Clear DTC and
Switch fault retest

B1222- Master NOTE: Refer to the electrical circuit


13 Lock/Unlock diagrams and check the master
Switch - Circuit This DTC will only set following the lock/unlock switch digital input
open completion of an on demand test routine circuits for open circuit, high
(routine 0202h) if the circuit is open resistance. Repair wiring harness as
required, clear the DTC and retest
Master lock/unlock switch digital the system
input circuit - open circuit, high If no wiring faults are present,
resistance check the center instrument panel
Switch fault switch pack master lock/unlock
switch and replace as required.
Clear DTC and retest

B1222- Master Master lock/unlock switch signal Refer to the electrical circuit
23 Lock/Unlock stuck low diagrams and check the master
Switch - Signal Switch activated for more than 15 lock/unlock switch digital input
stuck low seconds circuits for short circuit to ground,
Switch fault open circuit, high resistance. Repair
wiring harness as required, clear the
DTC and retest the system
If no wiring faults are present,
check the center instrument panel
switch pack master lock/unlock
switch and replace as required.
Clear DTC and retest

B1237- Gear Shift Module Transmission shift module wake-up Refer to the electrical circuit
11 Early Wake-up - control circuit - Circuit diagrams and check the
Circuit short to ETS_WAKE_UP - Short circuit to transmission shift module wake-up
ground ground control circuit - Circuit
ETS_WAKE_UP - For short circuit
to ground. Repair wiring harness as
required, clear the DTC and retest
the system

B12A6- Auxiliary Heater Auxiliary coolant pump circuit - Refer to the electrical circuit
11 Water Pump - Circuit AIRCON_WATER_PUMP diagrams and check the auxiliary
Circuit short to - Short circuit to ground coolant pump circuit - Circuit
ground Pump fault AIRCON_WATER_PUMP - For
short circuit to ground. Repair
wiring harness as required, clear the
DTC and retest the system
If no wiring faults are present,
check and install new air
conditioning water pump as
required. Clear DTC and retest

B12A6- Auxiliary Heater Auxiliary coolant pump circuit - Refer to the electrical circuit
15 Water Pump - Circuit AIRCON_WATER_PUMP diagrams and check the auxiliary
Circuit short to - Short circuit to power, open coolant pump circuit - Circuit
battery or open circuit, high resistance AIRCON_WATER_PUMP - For
Pump fault short circuit to power, open circuit,
high resistance. Repair wiring
harness as required, clear the DTC
and retest the system
If no wiring faults are present,
check and install new air
conditioning water pump as
required. Clear DTC and retest

B12E7- Glove-box NOTE: Refer to the electrical circuit


13 Locking Switch - diagrams and check the glovebox
Circuit open This DTC will only set following the locking switch digital input circuit
completion of an on demand test routine for open circuit, high resistance.
(routine 0202h) if the circuit is open Repair wiring harness as required,
clear the DTC and retest the system
Glovebox locking switch digital If no wiring faults are present,
input circuit - open circuit, high check and install new glovebox
resistance locking switch as required. Clear
Switch fault DTC and retest

B12E7- Glove-box Glovebox locking switch signal Refer to the electrical circuit
23 Locking Switch - stuck low diagrams and check the glovebox
Signal stuck low Switch activated for more than 10 locking switch digital input circuit
seconds for short circuit to ground, open
Switch fault circuit, high resistance. Repair
wiring harness as required, clear the
DTC and retest the system
If no wiring faults are present,
check and install new glovebox
locking switch as required. Clear
DTC and retest

B131A- Delayed power off Adaptive damping ride control, Clear DTC and retest. If fault
12 relay - Circuit overhead console lamp, glove persists, check and install a new
short to battery compartment lamp, right and left central junction box as required.
side front footwell lamps, glove Clear DTC and retest the system
compartment control module, right Refer to the warranty policy and
and left side sunvisor lamps, rear procedures manual, or determine if
interior lamp switched power any prior approval programme is in
circuits - Circuits ADRC_PWR, operation, prior to the installation of
LAMP_SWITCHED_PWR - Short a new module/component
circuit to power
Delayed power off relay fault

B131A- Delayed power off Delayed power off relay fault Check and install new delayed
93 relay - No Delayed power off relay either power off relay as required. Clear
operation stuck open or stuck closed DTC and retest

B13CA- Left Static Left side static bending lamp power Refer to the electrical circuit
11 Cornering Lamp supply circuit - Circuit diagrams and check the left side
Power Feed - LH_SBL_PWR - Short circuit to static bending lamp power supply
Circuit short to ground circuit - Circuit LH_SBL_PWR -
ground Lamp LED array fault For short circuit to ground. Repair
wiring harness as required, clear the
DTC and retest the system
If no wiring faults are present,
check and install new lamp LED
array as required. Clear DTC and
retest

B13CA- Left Static Left side static bending lamp power Refer to the electrical circuit
15 Cornering Lamp supply circuit - Circuit diagrams and check the left side
Power Feed - LH_SBL_PWR - Short circuit to static bending lamp power supply
Circuit short to power, open circuit, high resistance circuit - Circuit LH_SBL_PWR -
battery or open Lamp LED array fault For short circuit to power, open
circuit, high resistance. Repair
wiring harness as required, clear the
DTC and retest the system
If no wiring faults are present,
check and install new lamp LED
array as required. Clear DTC and
retest

B13CB- Roof Blind Sunblind power supply circuit - Refer to the electrical circuit
11 Module - Circuit short circuit to ground diagrams and check the sunblind
short to ground Motor fault power supply circuit for short
circuit to ground. Repair wiring
harness as required, clear the DTC
and retest the system
If no wiring faults are present,
check and install new sunblind
motor as required. Clear DTC and
retest

B13CC- Right Static Right side static bending lamp Refer to the electrical circuit
11 Cornering Lamp power supply circuit - Circuit diagrams and check the right side
Power Feed - RH_SBL_PWR - Short circuit to static bending lamp power supply
Circuit short to ground circuit - Circuit RH_SBL_PWR -
ground Lamp LED array fault For short circuit to ground. Repair
wiring harness as required, clear the
DTC and retest the system
If no wiring faults are present,
check and install new lamp LED
array as required. Clear DTC and
retest

B13CC- Right Static Right side static bending lamp Refer to the electrical circuit
15 Cornering Lamp power supply circuit - Circuit diagrams and check the right side
Power Feed - RH_SBL_PWR - Short circuit to static bending lamp power supply
Circuit short to power, open circuit, high resistance circuit - Circuit RH_SBL_PWR -
battery or open Lamp LED array fault For short circuit to power, open
circuit, high resistance. Repair
wiring harness as required, clear the
DTC and retest the system
If no wiring faults are present,
check and install new lamp LED
array as required. Clear DTC and
retest

B13CE- Left Daytime Left side daytime running lamp and Refer to the electrical circuit
11 Running Lamp position lamp power supply circuit - diagrams and check the left side
And Position Circuit LH_PL_DRL_PWR - Short daytime running lamp and position
Lamp Power Feed circuit to ground lamp power supply circuit - Circuit
- Circuit short to Lamp LED array fault LH_PL_DRL_PWR - For short
ground circuit to ground. Repair wiring
harness as required, clear the DTC
and retest the system
If no wiring faults are present,
check and install new lamp LED
array as required. Clear DTC and
retest

B13D1- Right Daytime Right side daytime running lamp Refer to the electrical circuit
11 Running Lamp and position lamp power supply diagrams and check the right side
And Position circuit - Circuit daytime running lamp and position
Lamp Power Feed RH_PL_DRL_PWR - Short circuit lamp power supply circuit - Circuit
- Circuit short to to ground RH_PL_DRL_PWR - For short
ground Lamp LED array fault circuit to ground. Repair wiring
harness as required, clear the DTC
and retest the system
If no wiring faults are present,
check and install new lamp LED
array as required. Clear DTC and
retest

B13D3- Left Daytime Left side daytime running lamp and Refer to the electrical circuit
11 Running Lamp position lamp control circuit - diagrams and check the left side
And Position Circuit LH_PL_DRL_CTRL - daytime running lamp and position
Lamp Control - Short circuit to ground lamp control circuit - Circuit
Circuit short to Lamp LED array fault LH_PL_DRL_CTRL - For short
ground circuit to ground. Repair wiring
harness as required, clear the DTC
and retest the system
If no wiring faults are present,
check and install new lamp LED
array as required. Clear DTC and
retest

B13D4- Right Daytime Right side daytime running lamp Refer to the electrical circuit
11 Running Lamp and position lamp control circuit - diagrams and check the right side
And Position Circuit RH_PL_DRL_CTRL - daytime running lamp and position
Lamp Control - Short circuit to ground lamp control circuit - Circuit
Circuit short to Lamp LED array fault RH_PL_DRL_CTRL - For short
ground circuit to ground. Repair wiring
harness as required, clear the DTC
and retest the system
If no wiring faults are present,
check and install new lamp LED
array as required. Clear DTC and
retest

B13D7- Cigar Lighter - Cigar lighter relay control circuit - Refer to the electrical circuit
12 Circuit short to short circuit to power diagrams and check the cigar
battery Cigar lighter relay fault lighter relay control circuit for short
circuit to power. Repair wiring
harness as required, clear the DTC
and retest the system
If no wiring faults are present,
check and install new cigar lighter
relay as required. Clear DTC and
retest

B13D9- Cabin Ignition Cabin ignition supply 1 circuit - Refer to the electrical circuit
11 Supply 1 - Circuit Circuit IGN_SUPPLY_1_CABIN - diagrams and check the cabin
short to ground Short circuit to ground ignition supply 1 circuit - Circuit
IGN_SUPPLY_1_CABIN - For
short circuit to ground. Repair
wiring harness as required, clear the
DTC and retest the system

B13DA- Cabin Ignition Cabin ignition supply 2 circuit - Refer to the electrical circuit
11 Supply 2 - Circuit Circuit IGN_SUPPLY_2_CABIN - diagrams and check the cabin
short to ground Short circuit to ground ignition supply 2 circuit - Circuit
Electronic differential ignition IGN_SUPPLY_2_CABIN - For
supply 2 circuit - Circuit short circuit to ground. Repair
IGN_SUPPLY_2_EDIFF - Short wiring harness as required, clear the
circuit to ground DTC and retest the system
Refer to the electrical circuit
diagrams and check the electronic
differential ignition supply 2 circuit
- Circuit IGN_SUPPLY_2_CABIN
- For short circuit to ground. Repair
wiring harness as required, clear the
DTC and retest the system

B1A85- Ambient Light Rain sensor/ambient light sensor Check the rain/light sensor is not
96 Sensor - obscured obscured. Check the security and
Component Sensor incorrectly installed installation of the rain/light sensor.
internal failure Component failure Clear DTC and retest
If the DTC returns, check and
install a new rain sensor/ambient
light sensor. Refer to the warranty
policy and procedures manual, or
determine if any prior approval
programme is in operation, prior to
the installation of a new
module/component

B1C45- Front Wiper Park NOTE: Refer to the electrical circuit


13 Position Switch - diagrams and check windshield
Circuit open This DTC will only set following the wiper motor park switch signal
completion of an on demand test routine circuit for open circuit, high
(routine 0202h) if the circuit is open resistance. Repair wiring harness as
required, clear the DTC and retest
Windshield wiper motor park the system
switch signal circuit - open circuit, If no wiring faults are present,
high resistance check and install new windshield
Switch fault wiper motor park position switch as
required. Clear DTC and retest

B1C45- Front Wiper Park Windshield wiper motor park Refer to the electrical circuit
23 Position Switch - position switch signal stuck low diagrams and check the master
Signal stuck low Switch fault lock/unlock switch digital input
circuits for short circuit to ground,
open circuit, high resistance. Repair
wiring harness as required, clear the
DTC and retest the system
If no wiring faults are present,
check and install new windshield
wiper motor park position switch as
required. Clear DTC and retest

B1C78- Powerwash Relay Powerwash relay control circuit - Refer to the electrical circuit
12 - Circuit short to short circuit to power diagrams and check the powerwash
battery Powerwash pump relay fault relay control circuit for short circuit
to power. Repair wiring harness as
required, clear the DTC and retest
the system
If no wiring faults are present,
check and install new powerwash
pump relay as required. Clear DTC
and retest

B1C79- Front Washer Screenwash pump control circuit - Refer to the electrical circuit
11 Pump - Circuit short circuit to ground diagrams and check the screenwash
short to ground Pump fault pump control circuit for short
circuit to ground. Repair wiring
harness as required, clear the DTC
and retest the system
If no wiring faults are present,
check and install new windscreen
washer pump as required. Clear
DTC and retest

B1C79- Front Washer Screenwash pump control circuit - Refer to the electrical circuit
15 Pump - Circuit short circuit to power, open circuit, diagrams and check the screenwash
short to battery or high resistance pump control circuit for short
open Pump fault circuit to power, open circuit, high
resistance. Repair wiring harness as
required, clear the DTC and retest
the system
If no wiring faults are present,
check and install new windscreen
washer pump as required. Clear
DTC and retest

B1C98- Left Corner Lamp Left side static bending lamp Refer to the electrical circuit
11 Circuit - Circuit control circuit - Circuit diagrams and check the left side
short to ground LH_SBL_CTRL - Short circuit to static bending lamp control circuit -
ground Circuit LH_SBL_CTRL - For short
Lamp LED array fault circuit to ground. Repair wiring
harness as required, clear the DTC
and retest the system
If no wiring faults are present,
check and install new lamp LED
array as required. Clear DTC and
retest

B1C99- Right Corner Right side static bending lamp Refer to the electrical circuit
11 Lamp Circuit - control circuit - Circuit diagrams and check the right side
Circuit short to RH_SBL_CTRL - Short circuit to static bending lamp control circuit -
ground ground Circuit 9H_SBL_CTRL - For short
Lamp LED array fault circuit to ground. Repair wiring
harness as required, clear the DTC
and retest the system
If no wiring faults are present,
check and install new lamp LED
array as required. Clear DTC and
retest

B1D00- Left Low Beam - Left side dip beam circuit - short Refer to the electrical circuit
11 Circuit short to circuit to ground diagrams and check the left side dip
ground beam circuit for short circuit to
ground. Repair wiring harness as
required, clear the DTC and retest
the system

B1D00- Left Low Beam - Left side dip beam circuit - short Refer to the electrical circuit
15 Circuit short to circuit to power, open circuit, high diagrams and check the left side dip
battery or open resistance beam circuit for short circuit to
power, open circuit, high resistance.
Repair wiring harness as required,
clear the DTC and retest the system
B1D01- Right Low Beam - Right side dip beam circuit - short Refer to the electrical circuit
11 Circuit short to circuit to ground diagrams and check the right side
ground dip beam circuit for short circuit to
ground. Repair wiring harness as
required, clear the DTC and retest
the system

B1D01- Right Low Beam - Right side dip beam circuit - short Refer to the electrical circuit
15 Circuit short to circuit to power, open circuit, high diagrams and check the right side
battery or open resistance dip beam circuit for short circuit to
power, open circuit, high resistance.
Repair wiring harness as required,
clear the DTC and retest the system

B1D02- Left High Beam Left side high beam circuit - Circuit Refer to the electrical circuit
11 Circuit - Circuit LH_MAIN_BEAM_SHUTTER - diagrams and check the left side dip
short to ground Short circuit to ground beam circuit - Circuit
LH_MAIN_BEAM_SHUTTER -
For short circuit to ground. Repair
wiring harness as required, clear the
DTC and retest the system

B1D02- Left High Beam Left side dip beam circuit - Circuit Refer to the electrical circuit
15 Circuit - Circuit LH_MAIN_BEAM_SHUTTER - diagrams and check the left side dip
short to battery or Short circuit to power, open circuit, beam circuit - Circuit
open high resistance LH_MAIN_BEAM_SHUTTER -
For short circuit to power, open
circuit, high resistance. Repair
wiring harness as required, clear the
DTC and retest the system

B1D03- Right High Beam Right side high beam circuit - Refer to the electrical circuit
11 Circuit - Circuit Circuit diagrams and check the right side
short to ground RH_MAIN_BEAM_SHUTTER - dip beam circuit - Circuit
Short circuit to ground RH_MAIN_BEAM_SHUTTER -
For short circuit to ground. Repair
wiring harness as required, clear the
DTC and retest the system

B1D03- Right High Beam Right side dip beam circuit - Circuit Refer to the electrical circuit
15 Circuit - Circuit RH_MAIN_BEAM_SHUTTER - diagrams and check the right side
short to battery or Short circuit to power, open circuit, dip beam circuit - Circuit
open high resistance RH_MAIN_BEAM_SHUTTER -
For short circuit to power, open
circuit, high resistance. Repair
wiring harness as required, clear the
DTC and retest the system

B1D17- Battery Backed Battery backed sounder/inclination Refer to the electrical circuit
11 Sounder - Circuit sensor power circuit - Circuit diagrams and check the battery
short to ground BBS_INCL_PWR - Short circuit to backed sounder/inclination sensor
ground power circuit - Circuit
Battery backed sounder/inclination BBS_INCL_PWR - For short
sensor fault circuit to ground. Repair wiring
harness as required, clear the DTC
and retest the system
If no wiring faults are present,
check and install new battery
backed sounder/inclination sensor
as required. Clear DTC and retest.
Refer to the warranty policy and
procedures manual, or determine if
any prior approval programme is in
operation, prior to the installation of
a new module/component

B1D17- Battery Backed Loss of LIN communication with Refer to the electrical circuit
87 Sounder - Missing battery backed sounder/inclination diagrams and check the power and
message sensor ground connections to the battery
Battery backed sounder/inclination backed sounder/inclination sensor.
sensor fault Refer to circuit diagrams and check
LIN bus circuits. Clear DTC and
retest
If no circuit faults are present,
check and install new battery
backed sounder/inclination sensor
as required. Refer to the warranty
policy and procedures manual, or
determine if any prior approval
programme is in operation, prior to
the installation of a new
module/component

B1D17- Battery Backed Battery backed sounder/inclination Clear the DTC and retest, if the
96 Sounder - sensor fault problem persists check and install
Component new battery backed
internal failure sounder/inclination sensor as
required. Refer to the warranty
policy and procedures manual, or
determine if any prior approval
programme is in operation, prior to
the installation of a new
module/component

B1D18- Volumetric Sensor Overhead console intrusion sensor Clear the DTC and retest, if the
96 - Component fault problem persists check and install
internal failure new intrusion sensor as required.
Refer to the warranty policy and
procedures manual, or determine if
any prior approval programme is in
operation, prior to the installation of
a new module/component

B1D97- Tilt Sensor - Battery backed sounder/inclination Clear the DTC and retest, if the
96 Component sensor fault problem persists check and install
internal failure new battery backed
sounder/inclination sensor as
required. Refer to the warranty
policy and procedures manual, or
determine if any prior approval
programme is in operation, prior to
the installation of a new
module/component

P0571- Brake Switch A Footbrake switch signal circuit - Refer to the electrical circuit
13 Circuit - Circuit open circuit, high resistance diagrams and check the footbrake
open switch signal circuit for open
circuit, high resistance. Repair
wiring harness as required, clear the
DTC and retest the system

P0801- Reverse Inhibit Mirror dim reverse gear inhibit Refer to electrical circuit diagrams
11 Control Circuit - circuit - Circuit and check the mirror dim reverse
Circuit short to REVERSE_INHIBIT - Short circuit gear inhibit circuit - Circuit
ground to ground REVERSE_INHIBIT - Between the
central junction box and the electro
chromatic rear view mirror for short
to ground. Repair wiring as
required, clear DTC and test system
operation

P0850- Park/Neutral NOTE: Refer to the electrical circuit


13 Switch Input diagrams and check the park/neutral
Circuit - Circuit This DTC will only set following the signal circuit for open circuit, high
open completion of an on demand test routine resistance. Repair wiring harness as
(routine 0202h) if the circuit is open required, clear the DTC and retest
the system
Park/neutral signal circuit - open
circuit, high resistance

P1624- Anti-theft System NOTE: Refer to the electrical circuit


13 - Circuit open diagrams and check the rear
This DTC will only set following the junction box anti-theft signal circuit
completion of an on demand test routine - Circuit RSJB_ANTITHEFT - For
(routine 0202h) if the circuit is open open circuit, high resistance. Repair
wiring harness as required, clear the
Rear junction box anti-theft signal DTC and retest the system
circuit - Circuit
RSJB_ANTITHEFT - Open circuit,
high resistance

P254F- Engine Hood NOTE: Refer to the electrical circuit


13 Switch diagrams and check the hood ajar
Circuit/Open - This DTC will only set following the switch signal circuit - Circuit
Circuit open completion of an on demand test routine BONNET_AJAR_SW - For open
(routine 0202h) if the circuit is open circuit, high resistance. Repair
wiring harness as required, clear the
Hood ajar switch signal circuit - DTC and retest the system
Circuit BONNET_AJAR_SW - If no wiring faults are present,
Open circuit, high resistance check and install new hood ajar
Switch fault switch as required. Clear DTC and
retest

U0010- Medium speed Medium speed CAN failure - bus Refer to the electrical circuit
88 CAN off diagrams and check the central
communication junction box medium speed CAN
Bus - Bus off bus for short circuit to ground, short
circuit to power, open circuit, high
resistance, or short circuit between
the paired CAN wires

U0142- Lost Loss of CAN communication with Refer to the electrical circuit
00 communication rear junction box diagrams and check the power and
with Body Control ground connections to the rear
Module B - No junction box
sub type Using the manufacturer approved
information diagnostic system, complete a CAN
network integrity test. Refer to the
electrical circuit diagrams and
check the CAN network between
the rear junction box and the central
junction box
Check the rear junction box for
related DTCs and refer to the
relevant DTC index

U0155- Lost Loss of CAN communication with Refer to the electrical circuit
00 Communication instrument panel cluster control diagrams and check the power and
With Instrument module ground connections to the
Panel Cluster instrument panel cluster control
(IPC) Control module
Module - No sub Using the manufacturer approved
type information diagnostic system, complete a CAN
network integrity test. Refer to the
electrical circuit diagrams and
check the CAN network between
the instrument panel cluster control
module and the central junction box
Check the instrument panel cluster
control module for related DTCs
and refer to the relevant DTC index

U0164- Lost Loss of CAN communication with Refer to the electrical circuit
00 communication climate control module diagrams and check the power and
with HVAC ground connections to the climate
control module - control module
No sub type Using the manufacturer approved
information diagnostic system, complete a CAN
network integrity test. Refer to the
electrical circuit diagrams and
check the CAN network between
the climate control module and the
central junction box
Check the climate control module
for related DTCs and refer to the
relevant DTC index

U0199- Lost Loss of CAN communication with Refer to the electrical circuit
00 Communication driver's door module diagrams and check the power and
With 'Door ground connections to the driver's
Control Module door module
A' - No sub type Using the manufacturer approved
information diagnostic system, complete a CAN
network integrity test. Refer to the
electrical circuit diagrams and
check the CAN network between
the driver's door module and the
central junction box
Check the driver's door module for
related DTCs and refer to the
relevant DTC index

U0200- Lost Loss of CAN communication with Refer to the electrical circuit
00 Communication passenger door module diagrams and check the power and
With 'Door ground connections to the
Control Module B' passenger door module
- No sub type Using the manufacturer approved
information diagnostic system, complete a CAN
network integrity test. Refer to the
electrical circuit diagrams and
check the CAN network between
the passenger door module and the
central junction box
Check the passenger door module
for related DTCs and refer to the
relevant DTC index

U0214- Lost Loss of CAN communication with Refer to the electrical circuit
00 Communication keyless vehicle module diagrams and check the power and
With Remote ground connections to the keyless
Function vehicle module
Actuation - No Using the manufacturer approved
sub type diagnostic system, complete a CAN
information network integrity test. Refer to the
electrical circuit diagrams and
check the CAN network between
the keyless vehicle module and the
central junction box
Check the keyless vehicle module
for related DTCs and refer to the
relevant DTC index

U0231- Lost Loss of LIN communication with Refer to the electrical circuit
00 Communication rain/ambient light sensor diagrams and check the power and
With Rain Sensing ground connections to the
Module - No sub rain/ambient light sensor
type information Refer to the electrical circuit
diagrams and check the LIN
network between the rain/ambient
light sensor and the central junction
box
Clear the DTC and retest. If the
problem persists, renew the
rain/ambient light sensor. Refer to
the warranty policy and procedures
manual, or determine if any prior
approval programme is in
operation, prior to the installation of
a new module/component
U0231- Lost Loss of LIN communication with Refer to the electrical circuit
87 Communication rain/ambient light sensor diagrams and check the power and
With Rain Sensing ground connections to the
Module - Missing rain/ambient light sensor
message Refer to the electrical circuit
diagrams and check the LIN
network between the rain/ambient
light sensor and the central junction
box
Clear the DTC and retest. If the
problem persists, renew the
rain/ambient light sensor. Refer to
the warranty policy and procedures
manual, or determine if any prior
approval programme is in
operation, prior to the installation of
a new module/component

U0257- Lost Loss of CAN communication with Refer to the electrical circuit
00 Communication touch screen display control module diagrams and check the power and
Front ground connections to the touch
Controls/Display screen display control module
Interface Module - Using the manufacturer approved
No sub type diagnostic system, complete a CAN
information network integrity test. Refer to the
electrical circuit diagrams and
check the CAN network between
the touch screen display control
module and the central junction box
Check the touch screen display
control module for related DTCs
and refer to the relevant DTC index

U0300- Internal Control Central junction box not Re-configure the central junction
00 Module Software transmitting compatible car box using the manufacturer
Incompatibility - configuration data approved diagnostic system. Clear
No sub type DTCs and re-test
information If fault persists, check and install a
new central junction box. Refer to
the warranty policy and procedures
manual, or determine if any prior
approval programme is in
operation, prior to the installation of
a new module/component

U1000- Solid State Driver Central junction box output circuit - NOTE:
00 Protection Active Short circuit to ground, short circuit
- Driver Disabled to power The relevant output is disabled while this
- No sub type DTC is set. Do not clear the DTC until the
information fault has been rectified

Using the manufacturer approved


diagnostic system, check for other
central junction box short circuit to
ground and/or short circuit to power
DTCs and refer to the relevant DTC
index for corrective actions
Once circuit faults have been
rectified, clear DTC and retest

U1A14- CAN Initialisation Module internal CAN controller Re-configure the central junction
49 Failure - Internal failure box using the manufacturer
electronic failure approved diagnostic system. Clear
DTCs and re-test
If fault persists, check and install a
new central junction box. Refer to
the warranty policy and procedures
manual, or determine if any prior
approval programme is in
operation, prior to the installation of
a new module/component

U2008- Sensor Cluster - NOTE: Refer to the electrical circuit


13 Circuit open diagrams and check the instrument
This DTC will only set following the cluster security signal circuit for
completion of an on demand test routine open circuit, high resistance. Repair
(routine 0202h) if the circuit is open wiring harness as required, clear the
DTC and retest the system
Instrument cluster security signal
circuit - open circuit, high
resistance

U2010- Switch Switch/interior illumination supply Refer to the electrical circuit


11 Illumination - circuit - Circuit diagrams and check the
Circuit short to PWM_ILLUMINATION_SUPPLY switch/interior illumination supply
ground - Short circuit to ground circuit - Circuit
PWM_ILLUMINATION_SUPPLY
- For short circuit to ground. Repair
wiring harness as required, clear the
DTC and retest the system

U2010- Switch Switch/interior illumination supply Refer to the electrical circuit


15 Illumination - circuit - Circuit diagrams and check the
Circuit short to PWM_ILLUMINATION_SUPPLY switch/interior illumination supply
battery or open - Short circuit to power, open circuit - Circuit
circuit, high resistance PWM_ILLUMINATION_SUPPLY
- For short circuit to power, open
circuit, high resistance. Repair
wiring harness as required, clear the
DTC and retest the system

U2100- Initial Central junction box configuration Re-configure the central junction
00 Configuration Not data failure box using the manufacturer
Complete - No approved diagnostic system. Clear
sub type DTC and re-test
information Using the manufacturer approved
diagnostic system, complete a CAN
network integrity test
If fault persists, check and install a
new central junction box. Refer to
the warranty policy and procedures
manual, or determine if any prior
approval programme is in
operation, prior to the installation of
a new module/component

U2100- Initial Central junction box configuration Re-configure the central junction
56 Configuration Not data memory failure box using the manufacturer
Complete - approved diagnostic system. Clear
Invalid/incomplete DTC and re-test
configuration If fault persists, check and install a
new central junction box. Refer to
the warranty policy and procedures
manual, or determine if any prior
approval programme is in
operation, prior to the installation of
a new module/component

U3000- Control Module - Central junction box - Internal NOTE:


49 Internal electronic failure
failure The relevant output is disabled while this
DTC is set

Using the manufacturer approved


diagnostic system, check for other
central junction box short circuit to
ground and/or short circuit to power
DTCs and refer to the relevant DTC
index for corrective actions
Install a new central junction box as
required. Clear DTCs and retest

U3000- Control module - Incorrect car configuration data Re-configure the central junction
55 Not configured exchanged box using the manufacturer
approved diagnostic system. Clear
DTC and re-test
If fault persists, check and install a
central junction box. Refer to the
warranty policy and procedures
manual, or determine if any prior
approval programme is in
operation, prior to the installation of
a new module/component

U3000- Control module - Incorrect car configuration data Re-configure the central junction
56 Invalid/incomplete exchanged box using the manufacturer
configuration approved diagnostic system. Clear
DTC and re-test
If fault persists, check and install a
central junction box. Refer to the
warranty policy and procedures
manual, or determine if any prior
approval programme is in
operation, prior to the installation of
a new module/component

U3000- Control Module - Car configuration data not received Using the manufacturer approved
87 Missing message diagnostic system, complete a CAN
network integrity test. Refer to the
electrical circuit diagrams and
check the CAN network between
the rear junction box and the central
junction box
Check the rear junction box and
central junction box for related
DTCs and refer to the relevant DTC
index

U3002- Vehicle Vehicle/component mis-match. Install original central junction box,


81 Identification Corrupt VIN data being transmitted, check for DTCs and refer to
Number - Invalid central junction box previously relevant DTC index
serial data installed to other vehicle
received
U3003- Battery voltage - Signal compare failure Refer to relevant section of
62 Signal compare Central junction box voltage differs workshop manual and battery care
failure more than ±2V compared to rear manual. Check battery state of
junction box voltage charge and starting/charging system
performance. Check power supply
circuit from central junction box to
rear junction box through megafuse
assembly
Refer to electrical circuit diagrams
and check the power and ground
supply circuits to the central
junction box. Repair wiring harness
as required. Clear DTC and retest
Published: 30-May-2014

2012.0 XF (X250), 100-00

General Information

Diagnostic Trouble Code Index - DTC: Climate


Control Module (HVAC) (G1426779)
DESCRIPTION AND OPERATION
Climate Control Module (HVAC)
CAUTION:

Diagnosis by substitution from a donor vehicle is NOT acceptable. Substitution of control modules does not
guarantee confirmation of a fault, and may also cause additional faults in the vehicle being tested and/or the donor
vehicle

NOTES:

If the control module or a component is suspect and the vehicle remains under manufacturer warranty, refer to
the warranty policy and procedures manual, or determine if any prior approval programme is in operation,
prior to the installation of a new module/component

Generic scan tools may not read the codes listed, or may read only 5-digit codes. Match the 5 digits from the
scan tool to the first 5 digits of the 7-digit code listed to identify the fault (the last 2 digits give extra
information read by the manufacturer-approved diagnostic system)

When performing voltage or resistance tests, always use a digital multimeter accurate to three decimal places
and with a current calibration certificate. When testing resistance, always take the resistance of the digital
multimeter leads into account

Check and rectify basic faults before beginning diagnostic routines involving pinpoint tests

Inspect connectors for signs of water ingress, and pins for damage and/or corrosion

If diagnostic trouble codes are recorded and, after performing the pinpoint tests, a fault is not present, an
intermittent concern may be the cause. Always check for loose connections and corroded terminals

Where an 'on demand self-test' is referred to, this can be accessed via the 'diagnostic trouble code monitor' tab
on the manufacturers approved diagnostic system

Check DDW for open campaigns. Refer to the corresponding bulletins and SSMs which may be valid for the
specific customer complaint and carry out the recommendations as required

The table below lists all diagnostic trouble codes (DTCs) that could be logged in the climate control module, for
additional diagnosis and testing information refer to the relevant diagnosis and testing section. For additional
information, refer to: Climate Control System (412-00 Climate Control System - General Information, Diagnosis
and Testing).

DTC Description Possible Causes Action


B105A- Cabin Temperature In car Refer to the electrical circuit diagrams and check
01 Sensor Fan - General temperature the power and ground supplies to the in car
electrical failure sensor temperature and humidity sensor. Check the
aspirator aspirator diagnostic line for open circuit, short
circuit fault circuit. Repair wiring as required. Check and install
In car sensor a new sensor as required. Check and install a new
unit internal Climate Control Module as required. Refer to the
fault warranty policy and procedures manual if a module
is suspect

B1081- Left Temperature Left side blend Refer to the electrical circuit diagrams and check
00 Damper Motor - No sub stepper motor left side blend stepper motor circuit for short circuit
type information circuit short to ground, short circuit to power, open circuit, high
circuit to resistance. Clear DTC and retest
ground, short If fault persists, check and install a new left side
circuit to blend stepper motor as required
power, open Refer to the warranty policy and procedures
circuit, high manual, or determine if any prior approval
resistance programme is in operation, prior to the installation
Left side blend of a new module/component
stepper motor
failure

B1081- Left Temperature Left side blend Check and install a new left side blend stepper
49 Damper Motor - stepper motor motor as required
Internal electronic failure Refer to the warranty policy and procedures
failure manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

B1082- Right Temperature Right side Refer to the electrical circuit diagrams and check
00 Damper Motor - No sub blend stepper right side blend stepper motor circuit for short
type information motor circuit circuit to ground, short circuit to power, open
short circuit to circuit, high resistance. Clear DTC and retest
ground, short If fault persists, check and install a new right side
circuit to blend stepper motor as required
power, open Refer to the warranty policy and procedures
circuit, high manual, or determine if any prior approval
resistance programme is in operation, prior to the installation
Right side of a new module/component
blend stepper
motor failure

B1082- Right Temperature Right side Check and install a new right side blend stepper
49 Damper Motor - blend stepper motor as required
Internal electronic motor failure Refer to the warranty policy and procedures
failure manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

B1083- Recirculation Damper Recirculation Refer to the electrical circuit diagrams and check
01 Motor - General motor circuit recirculation motor circuit for short circuit to
electrical failure short circuit to ground, short circuit to power, open circuit, high
ground, short resistance. Clear DTC and retest
circuit to Check recirculation motor has not jammed or been
power, open obstructed
circuit, high Check and install a new recirculation motor as
resistance required
Recirculation Check and install a new climate control module as
motor jammed required
Recirculation Refer to the warranty policy and procedures
motor failure manual, or determine if any prior approval
Climate control programme is in operation, prior to the installation
module failure of a new module/component

B1085- Defroster Damper Foreign object NOTE:


00 Motor - No sub type obstructing
information windshield air This DTC may be stored even though no fault condition
distribution is present and should be ignored unless the customer has
door reported a climate control system concern. Verify the
Windshield air customer concern prior to diagnosis
distribution
motor circuit Check and remove any obstruction in windshield
short circuit to air distribution door
ground, short Refer to the electrical circuit diagrams and check
circuit to windshield air distribution motor circuit for short
power, open circuit to ground, short circuit to power, open
circuit, high circuit, high resistance. Clear DTC and retest
resistance Check and install a new windshield air distribution
Damaged door as required
windshield air Check and install a new windshield air distribution
distribution motor as required
door Refer to the warranty policy and procedures
Windshield air manual, or determine if any prior approval
distribution programme is in operation, prior to the installation
motor failure of a new module/component

B1085- Defroster Damper Windshield air Check and install a new windshield air distribution
49 Motor - Internal distribution motor as required
electronic failure motor failure Refer to the warranty policy and procedures
manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

B1086- Air Distribution Foreign object Check and remove any obstruction in footwell air
00 Damper Motor - No sub obstructing distribution door
type information footwell air Check and re-seat the footwell hush panel
distribution surrounding the centre console stack
door Refer to the electrical circuit diagrams and check
Foreign object footwell air distribution motor circuit for short
obstructing circuit to ground, short circuit to power, open
footwell air circuit, high resistance. Clear DTC and retest
distribution Check and install a new footwell air distribution
door level arm door as required
Footwell air Check and install a new footwell air distribution
distribution motor as required
motor circuit Refer to the warranty policy and procedures
short circuit to manual, or determine if any prior approval
ground, short programme is in operation, prior to the installation
circuit to of a new module/component
power, open
circuit, high
resistance
Damaged
footwell air
distribution
door
Footwell air
distribution
motor failure

B1086- Air Distribution Footwell air Check and install a new footwell air distribution
49 Damper Motor - distribution motor as required
Internal electronic motor failure Refer to the warranty policy and procedures
failure manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

B1087- LIN Bus 'A' - Bus off LIN bus 'A' Refer to the electrical circuit diagrams and check
88 circuit short LIN bus '1/A' circuit short circuit to ground, short
circuit to circuit to power, open circuit, high resistance. Clear
ground, short DTC and retest
circuit to Check and install new front actuators as required
power, open Check and install a new climate control module as
circuit, high required
resistance Refer to the warranty policy and procedures
All front manual, or determine if any prior approval
actuators failed programme is in operation, prior to the installation
Climate control of a new module/component
module failure

B1088- LIN Bus 'B' - Bus off LIN bus 'B' Refer to the electrical circuit diagrams and check
88 circuit short LIN bus '2/B' circuit short circuit to ground, short
circuit to circuit to power, open circuit, high resistance. Clear
ground, short DTC and retest
circuit to Check and install new front actuators as required
power, open Check and install a new climate control module as
circuit, high required
resistance Refer to the warranty policy and procedures
All front manual, or determine if any prior approval
actuators failed programme is in operation, prior to the installation
Climate control of a new module/component
module failure

B10BE- Solar Sensor - Circuit Solar sensor Refer to the electrical circuit diagrams and check
11 short to ground circuit short solar sensor circuit for short circuit to ground. Clear
circuit to DTC and retest
ground Check and install a new solar sensor as required
Solar sensor Check and install a new climate control module as
failure required
Climate control Refer to the warranty policy and procedures
module failure manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

B11ED- Electric Heater Control Event Clear the DTC. With engine coolant temperature
68 - Event information information - low, set climate control temperature to high and
electric heater retest. If DTC remains in isolation suspect the
invalid Electric booster heater. Check and install a new
communication electric heater module as required
message If additional LIN related DTCs are logged refer to
the actions for those DTCs
Refer to the warranty policy and procedures
manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

B11ED- Electric Heater Control LIN network Refer to the electrical circuit diagrams and check
87 - Missing message fault the power and ground supplies to the electric heater
Electric heater module. Check the LIN circuits. Repair any wiring
module fault harness faults, clear the DTC and retest the system.
If the fault persists, check and install a new electric
heater module as required
Refer to the warranty policy and procedures
manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

B11ED- Electric Heater Control LIN network Refer to the electrical circuit diagrams and check
96 - Component internal fault the power and ground supplies to the electric heater
failure Electric heater module. Check the LIN circuits. Repair any wiring
module fault harness faults, clear the DTC and retest the system.
If the fault persists, check and install a new electric
heater module as required
Refer to the warranty policy and procedures
manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

B11EE- A/C Compressor - Refrigerant Refer to the electrical circuit diagrams and check
01 General electrical solenoid valve refrigerant solenoid valve circuit for short circuit to
failure circuit short ground, short circuit to each other. Clear DTC and
circuit to retest
ground, short Check and install a new refrigerant solenoid valve
circuit to each as required
other Check and install a new climate control module as
Refrigerant required
solenoid valve Refer to the warranty policy and procedures
failure manual, or determine if any prior approval
Climate control programme is in operation, prior to the installation
module failure of a new module/component

B11F0- Air Intake Damper Recirculation Refer to the electrical circuit diagrams and check
11 Position Sensor - motor circuit recirculation motor circuit for short circuit to
Circuit short to ground short circuit to ground. Clear DTC and retest
ground Check and install a new recirculation motor as
Recirculation required
motor failure Check and install a new climate control module as
Climate control required
module failure Refer to the warranty policy and procedures
manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

B11F0- Air Intake Damper Recirculation Refer to the electrical circuit diagrams and check
15 Position Sensor - motor circuit recirculation motor circuit for short circuit to
Circuit short to battery short circuit to power, open circuit, high resistance. Clear DTC
or open power, open and retest
circuit, high Check and install a new recirculation motor as
resistance required
Recirculation Check and install a new climate control module as
motor failure required
Climate control Refer to the warranty policy and procedures
module failure manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

B11F8- Left Outer Vent - No Obstructed Check and remove any obstruction in left side outer
00 sub type information airflow vent register vent
Left side outer Refer to the electrical circuit diagrams and check
register vent the left side outer register vent motor circuit for
motor circuit short circuit to ground, short circuit to power, open
short circuit to circuit, high resistance. Clear DTC and retest
ground, short Check and install a new left side outer register vent
circuit to motor as required
power, open Refer to the warranty policy and procedures
circuit, high manual, or determine if any prior approval
resistance programme is in operation, prior to the installation
Left side outer of a new module/component
register vent
motor internal
fault

B11F8- Left Outer Vent - Left side outer Check and install a new left side outer register vent
49 Internal electronic register vent motor as required
failure motor internal Refer to the warranty policy and procedures
fault manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

B11F9- Left Inner Vent - No Obstructed Check and remove any obstruction in left side inner
00 sub type information airflow vent register vent
Left side inner Refer to the electrical circuit diagrams and check
register vent the left side inner register vent motor circuit for
motor circuit short circuit to ground, short circuit to power, open
short circuit to circuit, high resistance. Clear DTC and retest
ground, short Check and install a new left side inner register vent
circuit to motor as required
power, open Refer to the warranty policy and procedures
circuit, high manual, or determine if any prior approval
resistance programme is in operation, prior to the installation
Left side inner of a new module/component
register vent
motor internal
fault

B11F9- Left Inner Vent - Left inner Check and install a new left side inner register vent
49 Internal electronic outer register motor as required
failure vent motor Refer to the warranty policy and procedures
internal fault manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

B11FA- Right Outer Vent - No Obstructed Check and remove any obstruction in right side
00 sub type information airflow vent outer register vent
Right side Refer to the electrical circuit diagrams and check
outer register the right side outer register vent motor circuit for
vent motor short circuit to ground, short circuit to power, open
circuit short circuit, high resistance. Clear DTC and retest
circuit to Check and install a new right side outer register
ground, short vent motor as required
circuit to Refer to the warranty policy and procedures
power, open manual, or determine if any prior approval
circuit, high programme is in operation, prior to the installation
resistance of a new module/component
Right side
outer register
vent motor
internal fault

B11FA- Right Outer Vent - Right side Check and install a new right side outer register
49 Internal electronic outer register vent motor as required
failure vent motor Refer to the warranty policy and procedures
internal fault manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

B11FB- Right Inner Vent - No Obstructed Check and remove any obstruction in right side
00 sub type information airflow vent inner register vent
Right side Refer to the electrical circuit diagrams and check
inner register the right side inner register vent motor circuit for
vent motor short circuit to ground, short circuit to power, open
circuit short circuit, high resistance. Clear DTC and retest
circuit to Check and install a new right side inner register
ground, short vent motor as required
circuit to Refer to the warranty policy and procedures
power, open manual, or determine if any prior approval
circuit, high programme is in operation, prior to the installation
resistance of a new module/component
Right side
inner register
vent motor
internal fault

B11FB- Right Inner Vent - Right inner Check and install a new right side inner register
49 Internal electronic outer register vent motor as required
failure vent motor Refer to the warranty policy and procedures
internal fault manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

B11FF- A/C Refrigerant Insufficient Check the timestamp for the DTC to see if it was
84 Pressure - Signal below refrigerant in set during cold ambient conditions (below 9
allowable range system degrees C (49 degrees F). If so allow the vehicle to
Air warm soak to verify the DTC was set correctly
conditioning Check the refrigerant system using a suitable
compressor charging station
fault Check the air conditioning compressor for correct
Refrigerant operation
pressure sensor Check and install a new refrigerant pressure sensor
failure as required
Refrigerant Check and install a new refrigerant solenoid as
solenoid valve required
failure Check and install a new climate control module as
Climate control required
module failure Refer to the warranty policy and procedures
manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

B11FF- A/C Refrigerant Excessive Check the refrigerant system using a suitable
85 Pressure - Signal above refrigerant in charging station
allowable range system Check the condenser and pipework for damage or
Blockage in air restriction
conditioning Check the air conditioning fan for correct operation
system Check and install a new refrigerant pressure sensor
pipework or as required
condenser Check and install a new refrigerant solenoid as
Air required
conditioning Check and install a new climate control module as
fan inoperative required
Refrigerant Refer to the warranty policy and procedures
pressure sensor manual, or determine if any prior approval
failure programme is in operation, prior to the installation
Refrigerant of a new module/component
solenoid valve
failure
Climate control
module failure

B13C2- Front LIN fault Refer to the electrical circuit diagrams and check
92 Windscreen/Windshield CAN fault the LIN connection between the misting sensor and
Misting Sensor - Sensor fault the rear junction box
Performance or Climate control Refer to the electrical circuit diagrams and check
incorrect operation module failure the power and ground connections to the misting
sensor. Using the manufacturer approved
diagnostic system, complete a CAN network
integrity test. Clear DTC and retest
If fault persists, check and install a new misting
sensor as required
Check and install a new climate control module as
required
Refer to the warranty policy and procedures
manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

B1A59- Sensor 5 Volt Supply - Sensor 5 volt Refer to the electrical circuit diagrams and check
11 Circuit short to ground supply circuit sensor 5 volt supply circuit for short to ground
short circuit to Check and install a new refrigerant pressure sensor
ground as required
Refrigerant Check and install a new Fresh - Re-circulated air
pressure sensor mode motor as required
failure Check and install a new climate control module as
Fresh - Re- required
circulated air Refer to the warranty policy and procedures
mode motor manual, or determine if any prior approval
failure programme is in operation, prior to the installation
Climate control of a new module/component
module failure

B1A59- Sensor 5 Volt Supply - Sensor 5 volt Refer to the electrical circuit diagrams and check
13 Circuit open supply circuit sensor 5 volt supply circuit for open circuit, high
open circuit, resistance
high resistance Check and install a new refrigerant pressure sensor
Refrigerant as required
pressure sensor Check and install a new climate control module as
failure required
Climate control Refer to the warranty policy and procedures
module failure manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

B1A60- Pollution Sensor - Air quality Refer to the electrical circuit diagrams and check
11 Hydrocarbon - Circuit sensor circuit air quality sensor circuit for short circuit to ground
short to ground short circuit to Check and install a new air quality sensor as
ground required
Air quality Check and install a new climate control module as
sensor failure required
Climate control Refer to the warranty policy and procedures
module failure manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

B1A61- Cabin Temperature Cabin Refer to the electrical circuit diagrams and check
11 Sensor - Circuit short to temperature cabin temperature sensor circuit for short circuit to
ground sensor circuit ground
short to ground Check and install a new cabin temperature sensor
Cabin as required
temperature Check and install a new climate control module as
sensor failure required
Climate control Refer to the warranty policy and procedures
module failure manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

B1A61- Cabin Temperature Cabin Refer to the electrical circuit diagrams and check
15 Sensor - Circuit short to temperature cabin temperature sensor circuit for short circuit to
battery or open sensor circuit power, open circuit, high resistance
short circuit to Check and install a new cabin temperature sensor
power, open as required
circuit, high Check and install a new climate control module as
resistance required
Cabin Refer to the warranty policy and procedures
temperature manual, or determine if any prior approval
sensor failure programme is in operation, prior to the installation
Climate control of a new module/component
module failure

B1A63- Right Solar Sensor - Right solar Refer to the electrical circuit diagrams and check
11 Circuit short to ground sensor circuit right solar sensor circuit for short circuit to ground
short circuit to Check and install a new solar sensor as required
ground Refer to the warranty policy and procedures
Right solar manual, or determine if any prior approval
sensor failure programme is in operation, prior to the installation
of a new module/component

B1A64- Left Solar Sensor - Left solar Refer to the electrical circuit diagrams and check
11 Circuit short to ground sensor circuit left solar sensor circuit for short circuit to ground
short to ground Check and install a new solar sensor as required
Left solar Refer to the warranty policy and procedures
sensor failure manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

B1A67- Sensor Ground - Circuit Sensor(s) Refer to the electrical circuit diagrams and check
13 open ground circuit sensor circuit for open circuit. DTCs B1A61-15,
open circuit, B1A59-13 and P0530-15 will also be logged
high resistance Check and install a new climate control module as
Climate control required
module failure Refer to the warranty policy and procedures
manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

B1A69- Humidity Sensor - Humidity Refer to the electrical circuit diagrams and check
01 General electrical sensor circuit humidity sensor circuit for short circuit to ground,
failure fault short circuit to power, open circuit
Humidity Check and install a new combined cabin
sensor failure temperature & humidity sensor as required
Climate control Check and install a new climate control module as
module failure required
Refer to the warranty policy and procedures
manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

B1B62- Pollution Sensor - NOx Air quality Refer to the electrical circuit diagrams and check
11 - Circuit short to sensor circuit air quality sensor circuit for short circuit to ground
ground short circuit to Check and install a new air quality sensor as
ground required
Air quality Check and install a new climate control module as
sensor failure required
Climate control Refer to the warranty policy and procedures
module failure manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

B1B71- Evaporator Evaporator Refer to the electrical circuit diagrams and check
11 Temperature Sensor - temperature evaporator temperature sensor circuit for short
Circuit short to ground sensor circuit circuit to ground
short to ground Check and install a new evaporator temperature
Evaporator sensor as required
temperature Check and install a new climate control module as
sensor failure required
Climate control Refer to the warranty policy and procedures
module failure manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component
B1B71- Evaporator Evaporator Refer to the electrical circuit diagrams and check
15 Temperature Sensor - temperature evaporator temperature sensor circuit for short
Circuit short to battery sensor circuit circuit to power, open circuit, high resistance
or open short circuit to Check and install a new evaporator temperature
power, open sensor as required
circuit, high Check and install a new climate control module as
resistance required
Evaporator Refer to the warranty policy and procedures
temperature manual, or determine if any prior approval
sensor failure programme is in operation, prior to the installation
Climate control of a new module/component
module failure

B1B72- LIN Bus #1 Power LIN bus 1 Refer to the electrical circuit diagrams and check
11 Supply Circuit - Circuit circuit short to LIN bus 1 circuit for short circuit to ground
short to ground ground Check and install new motors as required
Defrost stepper Check and install a new climate control module as
motor failure required
Panel foot Refer to the warranty policy and procedures
stepper motor manual, or determine if any prior approval
failure programme is in operation, prior to the installation
Right side of a new module/component
blend stepper
motor failure
Left side blend
stepper motor
failure
Electric
booster heater
(diesel only)
Left side outer
register motor
failure
Left side inner
register motor
failure
Right side
outer register
motor failure
Right side
inner register
motor failure
Climate control
module failure

C1B14- Sensor Supply Voltage Wiring harness Refer to the electrical circuit diagrams and check
13 A - Circuit open fault the climate control sensor 5 volt supply circuit -
Recirculated Circuit HVAC_SENSOR_5V - For open circuit.
air motor Repair wiring as required. Clear the DTC and
internal fault retest. Refer to warranty policy and procedures
Climate control manual if a module/component is suspect
module failure If the fault persists, check and install new
recirculated air motor as required
Check and install a new climate control module as
required
Refer to the warranty policy and procedures
manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

C1B15- Sensor Supply Voltage Wiring harness Refer to the electrical wiring diagrams and check
13 B - Circuit open fault the sensor ground circuit - Circuit
HVAC_SENSOR_GND - For open circuit, high
resistance. Repair the wiring harness as required,
clear the DTC and retest

P0530- A/C Refrigerant Pressure sensor Refer to electrical circuit diagrams and check
11 Pressure Sensor A signal line refrigerant pressure sensor signal line for short
Circuit - Circuit short to short circuit to circuit to ground. Repair wiring as required, clear
ground ground DTC and retest.
Sensor failure If DTC persists, check and install new refrigerant
pressure sensor
Refer to the warranty policy and procedures
manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

P0530- A/C Refrigerant Pressure sensor Refer to electrical circuit diagrams and check
15 Pressure Sensor A signal line refrigerant pressure sensor signal line for short
Circuit - Circuit short to short circuit to circuit to power, open circuit, high resistance.
battery or open power, open Repair wiring as required, clear DTC and retest.
circuit, high If DTC persists, check and install new refrigerant
resistance pressure sensor
Sensor failure Refer to the warranty policy and procedures
manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

P0645- A/C Clutch Relay Air Refer to the electrical circuit diagrams and check
11 Control Circuit - conditioning fuse 35 5A mini in the engine junction box, replace
Circuit short to ground compressor as required
clutch relay Refer to the electrical circuit diagrams and check
control circuit the air conditioning compressor clutch relay control
short circuit to circuit between the climate control module and the
ground engine junction box for short circuit to ground
Refer to the electrical circuit diagrams and check
low side connection to engine control module from
relay 16 - HIGH CURRENT PETROL/DIESEL
EMS RELAY - Check output to fuse from relay 5 -
½ ISO COMPRESSOR CLUTCH RELAY - Repair
wiring as required, clear DTC and retest

U0010- Medium Speed CAN CAN circuit Refer to the electrical circuit diagrams and check
88 Communication Bus - short to the power and ground connections to the climate
Bus off ground, short control module. Using the manufacturer approved
to power, open diagnostic system, complete a CAN network
circuit integrity test. Clear DTC and retest
Climate control If fault persists, check and install a new climate
module failure control module as required
Refer to the warranty policy and procedures
manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component
U0300- Internal Control Central Re-configure the central junction box using the
00 Module Software junction box manufacturer approved diagnostic system, clear
Incompatibility - No not configured DTC and retest
sub type information Climate control Re-configure the climate control module using the
module not manufacturer approved diagnostic system
configured If fault persists, check and install a new climate
Climate control control module as required
module failure Refer to the warranty policy and procedures
manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

U1A14- CAN Initialisation Module Re-configure the climate control module using the
49 Failure - Internal internal CAN manufacturer approved diagnostic system. Clear
electronic failure controller DTCs and retest
failure If fault persists, check and install a new climate
control module
Refer to the warranty policy and procedures
manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

U3000- Control Module - Not Car Check car configuration file is correct. Check VIN
55 configured configuration is correct
file incorrect Re-configure the central junction box using the
Central manufacturer approved diagnostic system. Clear
junction box DTC and retest
not configured Re-configure the climate control module using the
Central manufacturer approved diagnostic system. Clear
junction box DTCs and retest
failure Check and install a central junction box as required
Refer to the warranty policy and procedures
manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

U3000- Control Module - CAN link fault Check the climate control module for related DTCs
87 Missing message between and refer to the relevant DTC index
instrument Refer to the electrical circuit diagrams and check
pack and the power and ground connections to the climate
climate control control module. Using the manufacturer approved
module diagnostic system, complete a CAN network
Climate control integrity test. Clear DTC and retest
module failure Check and install a new climate control module as
required
Refer to the warranty policy and procedures
manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

U3002- Vehicle Identification Central Check the climate control module for related DTCs
81 Number - Invalid serial junction box and refer to the relevant DTC index
data received not configured Re-configure the central junction box using the
Climate control manufacturer approved diagnostic system. Clear
module not DTC and retest
configured Check and install a new climate control module as
Climate control required
module failure Refer to the warranty policy and procedures
manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component
Published: 17-Apr-2014

2012.0 XF (X250), 100-00

General Information

Diagnostic Trouble Code Index - DTC: Digital Audio


Broadcast Module (DABM) (G1426780)
DESCRIPTION AND OPERATION
Digital Audio Broadcast Module (DABM)
CAUTION:

Diagnosis by substitution from a donor vehicle is NOT acceptable. Substitution of control modules does not
guarantee confirmation of a fault, and may also cause additional faults in the vehicle being tested and/or the donor
vehicle

NOTES:

If the control module or a component is suspect and the vehicle remains under manufacturer warranty, refer to
the warranty policy and procedures manual, or determine if any prior approval programme is in operation,
prior to the installation of a new module/component

Generic scan tools may not read the codes listed, or may read only 5-digit codes. Match the 5 digits from the
scan tool to the first 5 digits of the 7-digit code listed to identify the fault (the last 2 digits give extra
information read by the manufacturer-approved diagnostic system)

When performing voltage or resistance tests, always use a digital multimeter accurate to three decimal places
and with a current calibration certificate. When testing resistance, always take the resistance of the digital
multimeter leads into account

Check and rectify basic faults before beginning diagnostic routines involving pinpoint tests

Inspect connectors for signs of water ingress, and pins for damage and/or corrosion

If diagnostic trouble codes are recorded and, after performing the pinpoint tests, a fault is not present, an
intermittent concern may be the cause. Always check for loose connections and corroded terminals

Where an 'on demand self-test' is referred to, this can be accessed via the 'diagnostic trouble code monitor' tab
on the manufacturers approved diagnostic system

Check DDW for open campaigns. Refer to the corresponding bulletins and SSMs which may be valid for the
specific customer complaint and carry out the recommendations as required

The table below lists all diagnostic trouble codes (DTCs) that could be logged on the digital audio broadcast module,
for additional diagnosis and testing information refer to the relevant diagnosis and testing section. For additional
information, refer to: Information and Entertainment System (415-00 Information and Entertainment System -
General Information, Diagnosis and Testing).

DTC Description Possible Causes Action


B11A4- L-Band Digital audio Refer to electrical circuit diagrams and check digital audio
11 Antenna - broadcast L- broadcast L-band antenna circuit for short circuit to ground
Circuit band antenna
short to circuit - short
ground circuit to
ground

B11A4- L-Band Digital audio Refer to electrical circuit diagrams and check digital audio
15 Antenna - broadcast L- broadcast L-band antenna circuit for short circuit to power,
Circuit band antenna open circuit, high resistance
short to circuit - short
battery or circuit to
open power, open
circuit, high
resistance

B11A5- Band 3 Digital audio Refer to electrical circuit diagrams and check digital audio
11 Antenna - broadcast band broadcast band 3 antenna circuit for short circuit to ground
Circuit 3 antenna
short to circuit - short
ground circuit to
ground

B11A5- Band 3 Digital audio Refer to electrical circuit diagrams and check digital audio
15 Antenna - broadcast band broadcast band 3 antenna circuit for short circuit to power, open
Circuit 3 antenna circuit, high resistance
short to circuit - short
battery or circuit to
open power, open
circuit, high
resistance

U3000- Control System Clear the diagnostic trouble code and retest. If the diagnostic
04 Module - internal failure trouble code persists, check and install a new digital audio
System broadcast module, as required. Refer to the warranty policy and
internal procedures manual, or determine if any prior approval
failures programme is in operation, prior to the installation of a new
module

U3000- Control System Clear the diagnostic trouble code and retest. If the diagnostic
44 Module - internal failure trouble code persists, check and install a new digital audio
Data broadcast module, as required. Refer to the warranty policy and
memory procedures manual, or determine if any prior approval
failure programme is in operation, prior to the installation of a new
module

U3000- Control Incorrect Using the manufacturer approved diagnostic system select the
4A Module - digital audio vehicle configuration main menu, select configure existing
Incorrect broadcast modules menu and re-program the module. Clear the diagnostic
component module trouble code and retest
installed installed If the diagnostic trouble code persists, check and install a new
The module digital audio broadcast module, as required. Refer to the
has been warranty policy and procedures manual, or determine if any
installed to a prior approval programme is in operation, prior to the
vehicle not installation of a new module
configured to
accept it

U3000- Control Incorrect car Using the manufacturer approved diagnostic system select the
55 Module - configuration vehicle configuration main menu, select configure existing
Not file data modules menu and re-program the module. Clear the diagnostic
configured received trouble code and retest
If the diagnostic trouble code persists, check and install a new
digital audio broadcast module, as required. Refer to the
warranty policy and procedures manual, or determine if any
prior approval programme is in operation, prior to the
installation of a new module

U3000- Control Missing Using the manufacturer approved diagnostic system select the
87 Module - message vehicle configuration main menu, select configure existing
Missing modules menu and re-program the module. Clear the diagnostic
message trouble code and retest
Refer to the electrical circuit diagrams and check the MOST
network connections to the module

U3000- Control Component or Check that the digital audio broadcast module cooling vents/air
98 Module - system over circulation is not obstructed
Component temperature Cool the vehicle interior down by ensuring it is in the shade and
or system have the A/C on cool. When cool, clear the diagnostic trouble
over code and retest. If the problem persists, renew the digital audio
temperature broadcast module. Refer to the warranty policy and procedures
manual, or determine if any prior approval programme is in
operation, prior to the installation of a new module

U3003- Battery Digital audio Refer to relevant section of workshop manual and battery care
62 Voltage - broadcast manual. Check battery state of charge and starting/charging
Signal module system performance
compare voltage differs Refer to electrical wiring diagrams and check the power and
failure more than ±2V ground circuits to the digital audio broadcast module. Repair
compared to wiring harness as required. Clear diagnostic trouble code and
central retest
electronics
module
voltage
Published: 22-Jan-2018

2012.0 XF (X250), 100-00

General Information

Diagnostic Trouble Code Index - DTC: Driver Door


Module/Passenger Door Module (DDM/PDM) (G1426781)
DESCRIPTION AND OPERATION
Driver/Passenger Door Module (DDM/PDM)
CAUTIONS:

Diagnosis by substitution from a donor vehicle is NOT acceptable. Substitution of control modules does not
guarantee confirmation of a fault, and may also cause additional faults in the vehicle being tested and/or the
donor vehicle

The vehicle latches are non-serviceable. Lubrication must not be sprayed into or around the door latches. Care
should be taken when washing the vehicle to not spray water at or into the latches

NOTES:

If the control module or a component is suspect and the vehicle remains under manufacturer warranty, refer to
the Warranty Policy and Procedures manual, or determine if any prior approval programme is in operation,
prior to the installation of a new module/component.

Generic scan tools may not read the codes listed, or may read only 5-digit codes. Match the 5 digits from the
scan tool to the first 5 digits of the 7-digit code listed to identify the fault (the last 2 digits give extra
information read by the manufacturer-approved diagnostic system)

When performing voltage or resistance tests, always use a digital multimeter accurate to three decimal places
and with a current calibration certificate. When testing resistance, always take the resistance of the digital
multimeter leads into account

Check and rectify basic faults before beginning diagnostic routines involving pinpoint tests

Inspect connectors for signs of water ingress, and pins for damage and/or corrosion

If diagnostic trouble codes are recorded and, after performing the pinpoint tests, a fault is not present, an
intermittent concern may be the cause. Always check for loose connections and corroded terminals

Check DDW for open campaigns. Refer to the corresponding bulletins and SSMs which may be valid for the
specific customer complaint and carry out the recommendations as required.

The table below lists all Diagnostic Trouble Codes (DTCs) that could be logged in the Driver/Passenger Door
Modules (DDM/PDM). For additional diagnosis and testing information refer to the relevant diagnosis and testing
section. For additional information, refer to: Driver Door Module (419-10 Multifunction Electronic Modules,
Diagnosis and Testing).

DTC Description Possible Causes Action


B108F- Cabin Cabin lock/unlock Check the switch operation and serviceability.
23 Lock/Unlock switch signal stuck Refer to the electrical circuit diagrams and check
Switch - Signal Switch pressed for the switch circuit
stuck low longer than 20 seconds
Switch circuit short
circuit to power or
ground
Switch failure

B109C- Front Courtesy Short to ground Refer to the electrical circuit diagrams and test
11 Light - Circuit front courtesy light circuit for short to ground
short to ground
B109C- Front Courtesy Short to power or open Refer to the electrical circuit diagrams and test
15 Light - Circuit circuit front courtesy light circuit for short to power or
short to battery open circuit
or open
B10EB- Driver Door Short to ground Refer to the electrical circuit diagrams and test
11 Double Locking driver door double locking motor circuit for
Motor - Circuit short to ground
short to ground
B10EB- Driver Door Short to power or open Refer to the electrical circuit diagrams and test
15 Double Locking circuit driver door double locking motor circuit for
Motor - Circuit short to power or open circuit
short to battery
or open
B10EC- Passenger Door Short to ground Refer to the electrical circuit diagrams and test
11 Double Locking passenger door double locking motor circuit for
Motor - Circuit short to ground
short to ground
B10EC- Passenger Door Short to power or open Refer to the electrical circuit diagrams and test
15 Double Locking circuit passenger door double locking motor circuit for
Motor - Circuit short to power or open circuit
short to battery
or open
B10ED- Rear Door Driver Rear driver door double Refer to the electrical circuit diagrams and check
11 Side Double locking motor circuit the circuit
Locking Motor - short circuit to ground
Circuit short to
ground
B10ED- Rear Door Driver Rear driver door double Refer to the electrical circuit diagrams and check
15 Side Double locking motor circuit the circuit
Locking Motor - short circuit to power or
Circuit short to open circuit
battery or open
B10EE- Rear Door Rear passenger door Refer to the electrical circuit diagrams and check
11 Passenger Side double locking motor the circuit
Double Locking circuit short circuit to
Motor - Circuit ground
short to ground
B10EE- Rear Door Rear passenger door Refer to the electrical circuit diagrams and check
15 Passenger Side double locking motor the circuit
Double Locking circuit short circuit to
Motor - Circuit power or open circuit
short to battery
or open
B1108- Driver Door Short to ground Refer to the electrical circuit diagrams and test
11 Central Locking driver door central locking motor circuit for
Motor - Circuit short to ground
short to ground
B1108- Driver Door Short to power or open Refer to the electrical circuit diagrams and test
15 Central Locking circuit driver door central locking motor circuit for
Motor - Circuit short to power or open circuit
short to battery
or open
B1109- Passenger Door Short to ground Refer to the electrical circuit diagrams and test
11 Central Locking passenger door central locking motor circuit for
Motor - Circuit short to ground
short to ground
B1109- Passenger Door Short to power or open Refer to the electrical circuit diagrams and test
15 Central Locking circuit passenger door central locking motor circuit for
Motor - Circuit short to power or open circuit
short to battery
or open
B110A- Rear Door Driver Rear driver door central Refer to the electrical circuit diagrams and check
11 Side Central locking motor circuit the circuit
Locking Motor - short circuit to ground
Circuit short to
ground
B110A- Rear Door Driver Rear driver door central Refer to the electrical circuit diagrams and check
15 Side Central locking motor circuit the circuit
Locking Motor - short circuit to power or
Circuit short to open circuit
battery or open
B110B- Rear Door Rear passenger door Refer to the electrical circuit diagrams and check
11 Passenger Side central locking motor the circuit
Central Locking circuit short circuit to
Motor - Circuit ground
short to ground
B110B- Rear Door Rear passenger door Refer to the electrical circuit diagrams and check
15 Passenger Side central locking motor the circuit
Central Locking circuit short circuit to
Motor - Circuit power or open circuit
short to battery
or open
B1163- Left Mirror Short to ground Refer to the electrical circuit diagrams and test
11 Heater Output left mirror heater output circuit for short to
Short To Ground ground
- Circuit short to
ground
B1163- Left Mirror Short to power or open Refer to the electrical circuit diagrams and test
15 Heater Output circuit left mirror heater output circuit for short to
Short To Power - power or open circuit
Circuit short to
battery or open
B1164- Right Mirror Short to ground Refer to the electrical circuit diagrams and test
11 Heater Output right mirror heater output circuit for short to
Short To Ground ground
- Circuit short to
ground
B1164- Right Mirror Short to power or open Refer to the electrical circuit diagrams and test
15 Heater Output circuit right mirror heater output circuit for short to
Short To Power - power or open circuit
Circuit short to
battery or open
B1165- Left Front Puddle Short to ground Refer to the electrical circuit diagrams and test
11 Lamp Output left front puddle lamp output circuit for short to
Short To Ground ground
- Circuit short to
ground
B1165- Left Front Puddle Short to power or open Refer to the electrical circuit diagrams and test
15 Lamp Output circuit left front puddle lamp output circuit for short to
Open Load Or power or open circuit
Short To Power -
Circuit short to
battery or open
B1166- Right Front Short to ground Refer to the electrical circuit diagrams and test
11 Puddle Lamp right front puddle lamp output circuit for short to
Output Short To ground
Ground - Circuit
short to ground
B1166- Right Front Short to power or open Refer to the electrical circuit diagrams and test
15 Puddle Lamp circuit right front puddle lamp output circuit for short to
Output Open power or open circuit
Load Or Short
To Battery -
Circuit short to
battery or open
B117C- Rear Power Set when window is Check for mechanical problems with the window
07 Window Up - reversed during window operation. Check for obstructions in the window
Mechanical up due to mechanical channels and that the glass is not restricted in the
Failures problems, window full range of travel
channel restriction
preventing window
closure or Window
mechanism fault

B117C- Rear Power Door module internal Renew the relevant rear door module. Refer to
72 Window Up - relay sticking open the warranty policy and procedures manual if a
Actuator stuck module is suspect
open
B117C- Rear Power Door module internal Renew the relevant rear door module. Refer to
73 Window Up - relay sticking closed the warranty policy and procedures manual if a
Actuator stuck module is suspect
closed
B117C- Rear Power Set when auto window Check the window operation. Clear the DTC and
92 Window Up - up was interrupted (e.g. retest
Performance or by pressing local
incorrect switch)
operation
B117D- Rear Power Door module internal Renew the relevant rear door module. Refer to
72 Window Down - relay sticking open the warranty policy and procedures manual if a
Actuator stuck module is suspect
open
B117D- Rear Power Door module internal Renew the relevant rear door module. Refer to
73 Window Down - relay sticking closed the warranty policy and procedures manual if a
Actuator stuck module is suspect
closed
B117E- Front Power Set when window is Check for mechanical problems with the window
07 Window Up - reversed during window operation. Check for obstructions in the window
Mechanical up due to mechanical channels and that the glass is not restricted in the
Failures problems, window full range of travel
channel restriction
preventing window
closure or Window
mechanism fault

B117E- Front Power Door module internal Renew the relevant front door module. Refer to
72 Window Up - relay sticking open the warranty policy and procedures manual if a
Actuator stuck module is suspect
open
B117E- Front Power Door module internal Renew the relevant front door module. Refer to
73 Window Up - relay sticking closed the warranty policy and procedures manual if a
Actuator stuck module is suspect
closed
B117E- Front Power Set when auto window Check the window operation. Clear the DTC and
92 Window Up - up was interrupted (e.g. retest
Performance or by pressing local
incorrect switch)
operation
B117F- Front Power Door module internal Renew the relevant front door module. Refer to
72 Window Down - relay sticking open the warranty policy and procedures manual if a
Actuator stuck module is suspect
open
B117F- Front Power Door module internal Renew the relevant front door module. Refer to
73 Window Down - relay sticking closed the warranty policy and procedures manual if a
Actuator stuck module is suspect
closed
B1189- Front Window Missing signal from hall Refer to the electrical circuit diagrams and check
29 Position Sensor - sensor 1 or 2 the hall sensor circuit between the door module
Signal invalid Sensor circuit fault and window motor. Repair as necessary. If the
Hall sensor fault problem persists, renew the window motor

B118A- Rear Window Missing signal from hall Refer to the electrical circuit diagrams and check
29 Position Sensor - sensor 1 or 2 the hall sensor circuit between the door module
Signal invalid Sensor circuit fault and window motor. Repair as necessary. If the
Hall sensor fault problem persists, renew the window motor

B11D1- LIN Bus "C" - LIN Bus checksum Refer to the electrical circuit diagrams and check
83 Value of signal error; driver switchpack the LIN Bus circuit between the driver door
protection internal fault window switch and the door module. Check the
calculation connectors for integrity and security. Clear the
incorrect DTC and retest. If the problem persists, renew
the driver door window switch

B11D1- LIN Bus "C" - LIN Bus header error; Refer to the electrical circuit diagrams and check
86 Signal invalid driver switchpack the LIN Bus circuit between the driver door
internal fault window switch and the door module. Check the
connectors for integrity and security. Clear the
DTC and retest. If the problem persists, renew
the driver door window switch
B11D1- LIN Bus "C" - Slave node Refer to the electrical circuit diagrams and check
87 Missing message communication missing; the LIN Bus circuit between the driver door
driver switchpack window switch and the door module. Check the
internal fault connectors for integrity and security. Clear the
DTC and retest. If the problem persists, renew
the driver door window switch

B11F6- Driver Folding Driver folding mirror Refer to the electrical circuit diagrams and check
11 Mirror Motor - motor circuit short the mirror fold circuit between the drivers door
Circuit short to circuit to ground module and the mirror assembly. Repair as
ground Mirror motor failure necessary

B11F6- Driver Folding Driver mirror heater Refer to the electrical circuit diagrams and check
15 Mirror Motor - output circuit short the mirror fold circuit between the drivers door
Circuit short to circuit to power or open module and the mirror assembly. Repair as
battery or open circuit necessary
Mirror motor failure

B11F7- Passenger Passenger folding Refer to the electrical circuit diagrams and check
11 Folding Mirror mirror motor circuit the mirror fold circuit between the passenger
Motor - Circuit short circuit to ground door module and the mirror assembly. Repair as
short to ground Mirror motor failure necessary

B11F7- Passenger Passenger mirror heater Refer to the electrical circuit diagrams and check
15 Folding Mirror output circuit short the mirror fold circuit between the passenger
Motor - Circuit circuit to power or open door module and the mirror assembly. Repair as
short to battery circuit necessary
or open Mirror motor failure

B1A98- LIN Bus Circuit Value of signal Refer to the electrical circuit diagrams and check
83 #1 - Value of protection calculation the LIN Bus circuit between the rear door
signal protection incorrect control unit and the Driver Door Module. Check
calculation the connectors for integrity and security. Clear
incorrect the DTC and retest. If the problem persists,
renew the rear door control module

B1A98- LIN Bus Circuit Signal invalid Refer to the electrical circuit diagrams and check
86 #1 - Signal the LIN Bus circuit between the rear door
invalid control unit and the Driver Door Module. Check
the connectors for integrity and security. Clear
the DTC and retest. If the problem persists,
renew the rear door control module

B1A98- LIN Bus Circuit Missing message Refer to the electrical circuit diagrams and check
87 #1 - Missing the LIN Bus circuit between the rear door
message control unit and the Driver Door Module. Check
the connectors for integrity and security. Clear
the DTC and retest. If the problem persists,
renew the rear door control module

B1C09- Driver Left/Right Driver mirror Refer to the electrical circuit diagrams and check
11 Mirror Motor adjustment motor circuit the mirror motor circuit between the drivers door
Circuit - Circuit short circuit to ground module and the mirror assembly. Repair as
short to ground Mirror left/right motor necessary
failure
B1C09- Driver Left/Right Driver mirror Refer to the electrical circuit diagrams and check
15 Mirror Motor adjustment motor circuit the mirror motor circuit between the drivers door
Circuit - Circuit short circuit to power or module and the mirror assembly. Repair as
short to battery open circuit necessary
or open Mirror left/right motor
failure

B1C10- Driver Up/Down Driver mirror Refer to the electrical circuit diagrams and check
11 Mirror Motor adjustment motor circuit the mirror motor circuit between the drivers door
Circuit - Circuit short circuit to ground module and the mirror assembly. Repair as
short to ground Mirror motor failure necessary

B1C10- Driver Up/Down Driver mirror Refer to the electrical circuit diagrams and check
15 Mirror Motor adjustment motor circuit the mirror motor circuit between the drivers door
Circuit - Circuit short circuit to power or module and the mirror assembly. Repair as
short to battery open circuit necessary
or open Mirror motor failure

B1C11- Passenger Passenger mirror Refer to the electrical circuit diagrams and check
11 Left/Right Mirror adjustment motor circuit the mirror motor circuit between the passenger
Motor Circuit - short circuit to ground door module and the mirror assembly. Repair as
Circuit short to Mirror motor failure necessary
ground
B1C11- Passenger Passenger mirror Refer to the electrical circuit diagrams and check
15 Left/Right Mirror adjustment motor circuit the mirror motor circuit between the passenger
Motor Circuit - short circuit to power or door module and the mirror assembly. Repair as
Circuit short to open circuit necessary
battery or open Mirror motor failure

B1C12- Passenger Passenger mirror Refer to the electrical circuit diagrams and check
11 Up/Down Mirror adjustment motor circuit the mirror motor circuit between the passenger
Motor Circuit - short circuit to ground door module and the mirror assembly. Repair as
Circuit short to Mirror motor failure necessary
ground
B1C12- Passenger Passenger mirror Refer to the electrical circuit diagrams and check
15 Up/Down Mirror adjustment motor circuit the mirror motor circuit between the passenger
Motor Circuit - short circuit to power or door module and the mirror assembly. Repair as
Circuit short to open circuit necessary
battery or open Mirror motor failure

B1C13- Driver Up/Down Driver mirror Refer to the electrical circuit diagrams and check
11 Mirror Motor adjustment motor circuit the mirror motor circuit between the driver door
Feedback Circuit short circuit to ground module and the mirror assembly. Repair as
- Circuit short to Mirror motor failure necessary
ground
B1C13- Driver Up/Down Driver mirror Refer to the electrical circuit diagrams and check
15 Mirror Motor adjustment motor circuit the mirror motor circuit between the driver door
Feedback Circuit short circuit to power or module and the mirror assembly. Repair as
- Circuit short to open circuit necessary
battery or open Mirror motor failure

B1C14- Driver Left/Right Driver mirror Refer to the electrical circuit diagrams and check
11 Mirror Motor adjustment motor circuit the mirror motor circuit between the driver door
Feedback Circuit short circuit to ground module and the mirror assembly. Repair as
- Circuit short to Mirror motor failure necessary
ground
B1C14- Driver Left/Right Driver mirror Refer to the electrical circuit diagrams and check
15 Mirror Motor adjustment motor circuit the mirror motor circuit between the driver door
Feedback Circuit short circuit to power or module and the mirror assembly. Repair as
- Circuit short to open circuit necessary
battery or open Mirror motor failure

B1C15- Passenger Passenger mirror Refer to the electrical circuit diagrams and check
11 Up/Down Mirror adjustment motor circuit the mirror motor circuit between the passenger
Motor Feedback short circuit to ground door module and the mirror assembly. Repair as
Circuit - Circuit Mirror motor failure necessary
short to ground
B1C15- Passenger Passenger mirror Refer to the electrical circuit diagrams and check
15 Up/Down Mirror adjustment motor circuit the mirror motor circuit between the passenger
Motor Feedback short circuit to power or door module and the mirror assembly. Repair as
Circuit - Circuit open circuit necessary
short to battery Mirror motor failure
or open
B1C16- Passenger Passenger mirror Refer to the electrical circuit diagrams and check
11 Left/Right Mirror adjustment motor circuit the mirror motor circuit between the passenger
Motor Feedback short circuit to ground door module and the mirror assembly. Repair as
Circuit - Circuit Mirror motor failure necessary
short to ground
B1C16- Passenger Passenger mirror Refer to the electrical circuit diagrams and check
15 Left/Right Mirror adjustment motor circuit the mirror motor circuit between the passenger
Motor Feedback short circuit to power or door module and the mirror assembly. Repair as
Circuit - Circuit open circuit necessary
short to battery Mirror motor failure
or open
B1C39- Key Lock Switch Key lock switch signal Refer to the electrical circuit diagrams and the
29 - Signal invalid invalid, stuck/jammed key lock switch circuit. Clear the DTC and
Switch held for longer retest. If no other DTCs are present, ignore this
than 20 seconds fault. If the DTC returns, suspect an internal
Key lock switch circuit fault with the Central Junction Box. Refer to the
short to ground (where warranty policy and procedures manual if a
connected) module is suspect
Key lock switch failure
Central Junction Box
fault

B1D06- Left Turn Left turn signal short Refer to the electrical circuit diagrams and check
11 Indicator - circuit to ground left turn signal for short circuit to ground
Circuit short to
ground
B1D06- Left Turn Left turn signal short Refer to the electrical circuit diagrams and check
15 Indicator - circuit to power left turn signal for short circuit high resistance,
Circuit short to Left turn signal high open circuit
battery or open resistance, open circuit

B1D07- Right Turn Right turn signal short Refer to the electrical circuit diagrams and check
11 Indicator - circuit to ground right turn signal for short circuit to ground
Circuit short to
ground
B1D07- Right Turn Right turn signal circuit Refer to the electrical circuit diagrams and check
15 Indicator - short circuit to power right turn signal for short circuit high resistance,
Circuit short to Right turn signal circuit open circuit
battery or open high resistance, open
circuit

C1B14- Sensor Supply #1 Short to ground Refer to the electrical circuit diagrams and test
11 - Circuit short to window sensor supply circuit for short to ground
ground
C1B14- Sensor Supply #1 Short to power or open Refer to the electrical circuit diagrams and test
15 - Circuit short to circuit window sensor supply circuit for short to power
battery or open or open circuit

C1B15- Sensor Supply Hall sensor supply Refer to the electrical circuit diagrams and check
11 Voltage A - circuit short to ground the hall sensor supply circuit between the rear
Circuit short to Hall sensor fault door module and the window motor. If the
ground problem persists, renew the window motor

C1B15- Sensor Supply Hall sensor supply Refer to the electrical circuit diagrams and check
15 Voltage A - circuit short to power or the hall sensor supply circuit between the rear
Circuit short to open circuit door module and the window motor. If the
battery or open Hall sensor fault problem persists, renew the window motor

U0010- Medium speed Medium speed CAN Carry out network integrity test using
00 CAN communication Bus manufacturer approved diagnostic system. Refer
communication to electrical circuit diagrams and test Medium
Bus - No sub speed CAN network for open, short circuit and
type information high resistance

U0140- Lost Logged when Refer to the electrical circuit diagrams and test
00 Communication subscribed CAN power and ground supplies to Central Junction
With CJB - No message missing from Box. Check CAN network between Driver Door
sub type CJB Module and Central Junction Box. Carry out
information network integrity test using manufacturer
approved diagnostic system

U0208- Lost Missing message Refer to the electrical circuit diagrams and test
00 Communication power and ground supplies to Driver Seat
With Driver Seat Module. Check CAN network between Driver
Module (DSM) - Door Module and Driver Seat Module. Carry out
No sub type network integrity test using manufacturer
information approved diagnostic system

U0300- Internal Control Car configuration file NOTE:


00 Module Software mismatch with vehicle
Incompatibility - specification After updating the car configuration file, set the
No sub type ignition to on and wait 30 seconds before clearing the
information DTCs

Using the manufacturer approved diagnostic


system, check and up-date the car configuration
file as necessary

U2002- Switch - Signal Signal stuck high Clear DTC and re-test. If DTC remains, install a
24 stuck high new passenger side window switch
U2004- Auxiliary Switch Signal stuck high Refer to the electrical circuit diagrams and check
24 Pack - Signal Left or right rear door the left and right door switch circuits
stuck high local switch pressed for
longer than 20 seconds
Switch circuit short to
ground or power

U2010- Switch Switch illumination Refer to electrical circuit diagrams and check the
11 Illumination - circuit short to ground switch illumination circuit
Circuit short to
ground
U2012- Car Bus signal/message Cycle the ignition status and re-test. If DTC
08 Configuration failures remains, re-configure the RJB using the
Parameter(s) - manufacturer approved diagnostic system
Bus
signal/message
failures
U2013- Switch Pack - Signal stuck high Clear DTC and re-test. If DTC remains, install a
24 Signal stuck high new driver side window switch pack

U2014- Control Module Data Memory Failure Install a new DDM/PDM. Refer to the warranty
44 Hardware - Data policy and procedures manual if a module is
memory failure suspect

U2100- Initial No sub type information Re-configure the DDM/PDM using the
00 Configuration manufacturer approved diagnostic system
Not Complete -
No sub type
information
U2101- Control Module No sub type information Re-configure the module using the manufacturer
00 Configuration approved diagnostic system. Check the
Incompatible - configuration of the Car Configuration File
No sub type (CCF)
information
U3003- Battery Voltage - Mis-match of battery Check vehicle battery and charging system.
62 Signal compare voltage, of 2 volts or Refer to the relevant section in the workshop
failure lower, between manual. Refer to the electrical circuit diagrams
DDM/PDM and RJB and check the power and ground supply circuits
to both modules
Published: 17-Apr-2014

2012.0 XF (X250), 100-00

General Information

Diagnostic Trouble Code Index - DTC:


Driver/Passenger Seat Module (DSM/PSM) (G1426782)
DESCRIPTION AND OPERATION
Driver/Passenger Seat Module (DSM/PSM)
CAUTION:

Diagnosis by substitution from a donor vehicle is NOT acceptable. Substitution of control modules does not
guarantee confirmation of a fault, and may also cause additional faults in the vehicle being tested and/or the donor
vehicle

NOTES:

If the control module or a component is suspect and the vehicle remains under manufacturer warranty, refer to
the warranty policy and procedures manual, or determine if any prior approval programme is in operation,
prior to the installation of a new module/component

Generic scan tools may not read the codes listed, or may read only 5-digit codes. Match the 5 digits from the
scan tool to the first 5 digits of the 7-digit code listed to identify the fault (the last 2 digits give extra
information read by the manufacturer-approved diagnostic system)

When performing voltage or resistance tests, always use a digital multimeter accurate to three decimal places
and with a current calibration certificate. When testing resistance, always take the resistance of the digital
multimeter leads into account

Check and rectify basic faults before beginning diagnostic routines involving pinpoint tests

Inspect connectors for signs of water ingress, and pins for damage and/or corrosion

If diagnostic trouble codes are recorded and, after performing the pinpoint tests, a fault is not present, an
intermittent concern may be the cause. Always check for loose connections and corroded terminals

Where an 'on demand self-test' is referred to, this can be accessed via the 'diagnostic trouble code monitor' tab
on the manufacturers approved diagnostic system

Check DDW for open campaigns. Refer to the corresponding bulletins and SSMs which may be valid for the
specific customer complaint and carry out the recommendations as needed

The table below lists all Diagnostic Trouble Codes (DTCs) that could be logged in the Driver/Passenger Seat
Module, for additional Diagnosis and Testing information refer to the relevant Diagnosis and Testing Section. For
additional information, refer to: Seats (501-10 Seating, Diagnosis and Testing).

DTC Description Possible Causes Action


B105D- Seat Bolster Inflate Circuit short to ground Check the seat wiring
11 Output - Circuit short harness/connectors for
to ground security/integrity. Refer to the
electrical circuit diagrams and check
the seat bolster circuit
B105D- Seat Bolster Inflate Circuit short to power or Check the seat wiring
15 Output - Circuit short open harness/connectors for
to battery or open security/integrity. Refer to the
electrical circuit diagrams and check
the seat bolster circuit

B105E- Seat Bolster Deflate Circuit short to ground Check the seat wiring
11 Output - Circuit short harness/connectors for
to ground security/integrity. Refer to the
electrical circuit diagrams and check
the seat bolster circuit

B105E- Seat Bolster Deflate Circuit short to power or Check the seat wiring
15 Output - Circuit short open harness/connectors for
to battery or open security/integrity. Refer to the
electrical circuit diagrams and check
the seat bolster circuit

B1060- Seat Headrest Motor Circuit short to ground Check the seat wiring
11 Output - Circuit short harness/connectors for
to ground security/integrity. Refer to the
electrical circuit diagrams and check
the seat headrest motor circuit

B1060- Seat Headrest Motor Circuit short to power or Check the seat wiring
15 Output - Circuit short open harness/connectors for
to battery or open security/integrity. Refer to the
electrical circuit diagrams and check
the seat headrest motor circuit

B1064- Seat Headrest Motor Harness/connector problem Check the seat wiring
31 Sensor - No signal No signal from sensor harness/connectors for
Sensor/motor malfunction security/integrity
Refer to the electrical circuit diagrams
and check the seat headrest motor
sensor circuit. Repair circuit as
required. Clear DTC and retest

B1065- Cushion Extend Signal stuck high Check the switch function. Check the
24 Switch - Signal stuck Switch malfunction seat wiring harness/connectors for
high security/integrity. Refer to the
electrical circuit diagrams and check
the switch circuit

B1066- Cushion Retract Signal stuck high Check the switch function. Check the
24 Switch - Signal stuck Switch malfunction seat wiring harness/connectors for
high security/integrity. Refer to the
electrical circuit diagrams and check
the switch circuit

B1067- Lumbar In Switch - Signal stuck high Check the switch function. Check the
24 Signal stuck high Switch malfunction seat wiring harness/connectors for
security/integrity. Refer to the
electrical circuit diagrams and check
the switch circuit
B1068- Lumbar Out Switch - Signal stuck high Check the switch function. Check the
24 Signal stuck high Switch malfunction seat wiring harness/connectors for
security/integrity. Refer to the
electrical circuit diagrams and check
the switch circuit

B1069- Lumbar Up Switch - Signal stuck high Check the switch function. Check the
24 Signal stuck high Switch malfunction seat wiring harness/connectors for
security/integrity. Refer to the
electrical circuit diagrams and check
the switch circuit

B106A- Lumbar Down Signal stuck high Check the switch function. Check the
24 Switch - Signal stuck Switch malfunction seat wiring harness/connectors for
high security/integrity. Refer to the
electrical circuit diagrams and check
the switch circuit

B106B- Bolster Inflate Switch Signal stuck high Check the switch function. Check the
24 - Signal stuck high Switch malfunction seat wiring harness/connectors for
security/integrity. Refer to the
electrical circuit diagrams and check
the switch circuit

B106C- Bolster Deflate Signal stuck high Check the switch function. Check the
24 Switch - Signal stuck Switch malfunction seat wiring harness/connectors for
high security/integrity. Refer to the
electrical circuit diagrams and check
the switch circuit

B106D- Headrest Up Switch - Signal stuck high Check the switch function. Check the
24 Signal stuck high Switch malfunction seat wiring harness/connectors for
security/integrity. Refer to the
electrical circuit diagrams and check
the switch circuit

B106E- Headrest Down Signal stuck high Check the switch function. Check the
24 Switch - Signal stuck Switch malfunction seat wiring harness/connectors for
high security/integrity. Refer to the
electrical circuit diagrams and check
the switch circuit

B1087- LIN Bus "A" - Value LIN bus checksum error Check for other LIN Bus related DTCs.
83 of signal protection Value of signal Refer to the electrical circuit diagrams
calculation incorrect protection calculation and check the LIN Bus circuit
incorrect
Generic LIN bus failure

B1087- LIN Bus "A" - Signal Generic LIN bus failure Check for other LIN Bus related DTCs.
86 invalid Signal invalid Refer to the electrical circuit diagrams
LIN bus Bit error / and check the LIN Bus circuit
Parity Error /Synch
Error
B1087- LIN Bus "A" - Generic LIN bus failure Check for other LIN Bus related DTCs.
87 Missing message Missing message Refer to the electrical circuit diagrams
Slave not responding and check the LIN Bus circuit
or LIN bus short
circuit to ground or
power

B1136- Lumbar Control A - Circuit short to ground Check the seat wiring
11 Circuit short to harness/connectors for
ground security/integrity. Refer to the
electrical circuit diagrams and check
the lumbar control circuit

B1136- Lumbar Control A - Circuit short to power Check the seat wiring
12 Circuit short to harness/connectors for
battery security/integrity. Refer to the
electrical circuit diagrams and check
the lumbar control circuit

B1136- Lumbar Control A - Circuit open circuit Check the seat wiring
13 Circuit open harness/connectors for
security/integrity. Refer to the
electrical circuit diagrams and check
the lumbar control circuit

B1137- Lumbar Control B - Circuit short to ground Check the seat wiring
11 Circuit short to harness/connectors for
ground security/integrity. Refer to the
electrical circuit diagrams and check
the lumbar control circuit

B1137- Lumbar Control B - Circuit short to power Check the seat wiring
12 Circuit short to harness/connectors for
battery security/integrity. Refer to the
electrical circuit diagrams and check
the lumbar control circuit

B1137- Lumbar Control B - Circuit open circuit Check the seat wiring
13 Circuit open harness/connectors for
security/integrity. Refer to the
electrical circuit diagrams and check
the lumbar control circuit

B1138- Lumbar Control C - Circuit short to ground Check the seat wiring
11 Circuit short to harness/connectors for
ground security/integrity. Refer to the
electrical circuit diagrams and check
the lumbar control circuit

B1138- Lumbar Control C - Circuit short to power Check the seat wiring
12 Circuit short to harness/connectors for
battery security/integrity. Refer to the
electrical circuit diagrams and check
the lumbar control circuit
B1138- Lumbar Control C - Circuit open circuit Check the seat wiring
13 Circuit open harness/connectors for
security/integrity. Refer to the
electrical circuit diagrams and check
the lumbar control circuit

B1139- Lumbar Control D - Circuit short to ground Check the seat wiring
11 Circuit short to harness/connectors for
ground security/integrity. Refer to the
electrical circuit diagrams and check
the lumbar control circuit

B1139- Lumbar Control D - Circuit short to power Check the seat wiring
12 Circuit short to harness/connectors for
battery security/integrity. Refer to the
electrical circuit diagrams and check
the lumbar control circuit

B1139- Lumbar Control D - Circuit open circuit Check the seat wiring
13 Circuit open harness/connectors for
security/integrity. Refer to the
electrical circuit diagrams and check
the lumbar control circuit

B113A- General Failure on No sub type information Check the seat wiring
00 Seat Lumbar - No harness/connectors for
sub type information security/integrity. Refer to the
electrical circuit diagrams and check
the lumbar control circuit

B113B- Lumbar Control No sub type information Check the seat wiring
00 Multiple Failures - harness/connectors for
No sub type security/integrity. Refer to the
information electrical circuit diagrams and check
the lumbar control circuit

B12DB- Passenger Seat Massage pump electrical or Refer to the workshop manual and
00 Massage Module pneumatic connection check the pump unit electrical and
Pump Assembly - No disconnected pneumatic connections. If no faults are
sub type information Massage pump unit failure found check and install a new massage
module pump assembly. Refer to the
warranty policy and procedures manual
if a module is suspect

B12E6- Passenger Seat Massage unit valve block Refer to the workshop manual and
00 Massage Module electrical connection check the massage unit valve block for
Back Carrier disconnected of damaged damaged or disconnected wiring.
Assembly - No sub Massage unit valve block Check the pneumatic pipes and air
type information pneumatic pipe bladders for leaks/blockages. If no
disconnected/leaking/blocked external faults are found suspect an
Air bladder leaking internal fault within the massage
Massage electrical control control module or solenoid valves.
unit or solenoid failure Install a new assembly as required.
Refer to the warranty policy and
procedures manual if a module is
suspect
B13F6- Passenger Seat Away Passenger seat away switch Check the seat wiring
11 Switch - Circuit short circuit - short circuit to harness/connectors for
to ground ground security/integrity. Refer to the
Faulty switch electrical circuit diagrams and check
the passenger seat away switch circuit
for short circuit to ground
If no circuit faults are present, check
and install new passenger seat away
switch as required. Refer to the
warranty policy and procedures
manual, or determine if any prior
approval programme is in operation,
prior to the installation of a new
module/component

B1B86- Seat Height Motor Circuit short to ground Check the seat wiring
11 Relay - Circuit short harness/connectors for
to ground security/integrity. Refer to the
electrical circuit diagrams and check
the seat height motor circuit

B1B86- Seat Height Motor Circuit short to power or Check the seat wiring
15 Relay - Circuit short open harness/connectors for
to battery or open security/integrity. Refer to the
electrical circuit diagrams and check
the seat height motor circuit

B1B87- Seat Height Motor Harness/connector problem Check the seat wiring
31 Speed/Position No signal from sensor harness/connectors for
Sensor - No signal Sensor/motor malfunction security/integrity
Refer to the electrical circuit diagrams
and check the seat height motor sensor
circuit. Repair circuit as required. Clear
DTC and retest

B1B88- Seat Slide Motor Circuit short to ground Check the seat wiring
11 Relay - Circuit short harness/connectors for
to ground security/integrity. Refer to the
electrical circuit diagrams and check
the seat slide motor relay circuit

B1B88- Seat Slide Motor Circuit short to power or Check the seat wiring
15 Relay - Circuit short open circuit harness/connectors for
to battery or open security/integrity. Refer to the
electrical circuit diagrams and check
the seat slide motor relay circuit

B1B89- Seat Slide Motor Harness/connector problem Check the seat wiring
31 Speed/Position No signal from sensor harness/connectors for
Sensor - No signal Sensor/motor malfunction security/integrity
Refer to the electrical circuit diagrams
and check the seat slide motor speed
sensor circuit. Repair circuit as
required. Clear DTC and retest
B1B90- Seat Tilt Motor Relay Circuit short to ground Check the seat wiring
11 - Circuit short to harness/connectors for
ground security/integrity. Refer to the
electrical circuit diagrams and check
the seat tilt motor relay circuit

B1B90- Seat Tilt Motor Relay Circuit short to power or Check the seat wiring
15 - Circuit short to open circuit harness/connectors for
battery or open security/integrity. Refer to the
electrical circuit diagrams and check
the seat tilt motor relay circuit

B1B91- Seat Tilt Motor Harness/connector problem Check the seat wiring
31 Speed/Position No signal from sensor harness/connectors for
Sensor - No signal Sensor/motor malfunction security/integrity
Refer to the electrical circuit diagrams
and check the seat tilt motor speed
sensor circuit. Repair circuit as
required. Clear DTC and retest

B1B92- Seat Recline Motor Circuit short to ground Check the seat wiring
11 Relay - Circuit short harness/connectors for
to ground security/integrity. Refer to the
electrical circuit diagrams and check
the seat recline motor relay circuit

B1B92- Seat Recline Motor Circuit short to power or Check the seat wiring
15 Relay - Circuit short open circuit harness/connectors for
to battery or open security/integrity. Refer to the
electrical circuit diagrams and check
the seat recline motor relay circuit

B1B93- Seat Recline Motor Harness/connector problem Check the seat wiring
31 Speed/Position No signal from sensor harness/connectors for
Sensor - No signal Sensor/motor malfunction security/integrity
Refer to the electrical circuit diagrams
and check the seat recline motor speed
sensor circuit. Repair circuit as
required. Clear DTC and retest

B1B94- Seat Height Up Signal stuck high Check the switch function. Check the
24 Switch - Signal stuck Switch malfunction seat wiring harness/connectors for
high security/integrity. Refer to the
electrical circuit diagrams and check
the switch circuit

B1B95- Seat Height Down Signal stuck high Check the switch function. Check the
24 Switch - Signal stuck Switch malfunction seat wiring harness/connectors for
high security/integrity. Refer to the
electrical circuit diagrams and check
the switch circuit

B1B96- Seat Slide Forward Signal stuck high Check the switch function. Check the
24 Switch - Signal stuck Switch malfunction seat wiring harness/connectors for
high security/integrity. Refer to the
electrical circuit diagrams and check
the switch circuit

B1B97- Seat Slide Backward Signal stuck high Check the switch function. Check the
24 Switch - Signal stuck Switch malfunction seat wiring harness/connectors for
high security/integrity. Refer to the
electrical circuit diagrams and check
the switch circuit

B1B98- Seat Tilt Up Switch - Signal stuck high Check the switch function. Check the
24 Signal stuck high Switch malfunction seat wiring harness/connectors for
security/integrity. Refer to the
electrical circuit diagrams and check
the switch circuit

B1B99- Seat Tilt Down Signal stuck high Check the switch function. Check the
24 Switch - Signal stuck Switch malfunction seat wiring harness/connectors for
high security/integrity. Refer to the
electrical circuit diagrams and check
the switch circuit

B1C00- Seat Recline Up Signal stuck high Check the switch function. Check the
24 Switch - Signal stuck Switch malfunction seat wiring harness/connectors for
high security/integrity. Refer to the
electrical circuit diagrams and check
the switch circuit

B1C01- Seat Recline Down Signal stuck high Check the switch function. Check the
24 Switch - Signal stuck Switch malfunction seat wiring harness/connectors for
high security/integrity. Refer to the
electrical circuit diagrams and check
the switch circuit

B1C02- Memory Store Signal stuck high Check the switch function. Check the
24 Switch - Signal stuck Switch malfunction seat wiring harness/connectors for
high security/integrity. Refer to the
electrical circuit diagrams and check
the switch circuit

B1C03- Memory #1 Switch - Signal stuck high Check the switch function. Check the
24 Signal stuck high Switch malfunction seat wiring harness/connectors for
security/integrity. Refer to the
electrical circuit diagrams and check
the switch circuit

B1C04- Memory #2 Switch - Signal stuck high Check the switch function. Check the
24 Signal stuck high Switch malfunction seat wiring harness/connectors for
security/integrity. Refer to the
electrical circuit diagrams and check
the switch circuit

B1C05- Memory #3 Switch - Signal stuck high Check the switch function. Check the
24 Signal stuck high Switch malfunction seat wiring harness/connectors for
security/integrity. Refer to the
electrical circuit diagrams and check
the switch circuit
B1D94- Lumbar Motor Relay Circuit short to ground Check the seat wiring
11 - Circuit short to harness/connectors for
ground security/integrity. Refer to the
electrical circuit diagrams and check
the seat lumbar motor relay circuit

B1D94- Lumbar Motor Relay Circuit short to power or Check the seat wiring
15 - Circuit short to open circuit harness/connectors for
battery or open security/integrity. Refer to the
electrical circuit diagrams and check
the seat lumbar motor relay circuit

U0010- Medium speed CAN CAN signal fault Refer to the electrical circuit diagrams
88 Communication Bus Possible open circuit and check the power and ground
- Bus off Faulty Control module connections to the module. Using the
manufacturer approved diagnostic
system, complete a CAN network
integrity test. Refer to the electrical
circuit diagrams and check the CAN
network

U0140- Lost Communication No sub type information Refer to the electrical circuit diagrams
00 With Body Control and check the power and ground
Module - No sub type connections to the module. Using the
information manufacturer approved diagnostic
system, complete a CAN network
integrity test. Refer to the electrical
circuit diagrams and check the CAN
network between the Central Junction
Box and Seat Module

U0142- Lost Communication No sub type information Refer to the electrical circuit diagrams
00 With Body Control and check the power and ground
Module 'B' - No sub connections to the module. Using the
type information manufacturer approved diagnostic
system, complete a CAN network
integrity test. Refer to the electrical
circuit diagrams and check the CAN
network between the Rear Junction
Box and Seat Module

U0151- Lost communication Loss of CAN communication Refer to the electrical circuit diagrams
00 with Restraints with restraints control and check the power and ground
Control Module - No module connections to the restraints control
sub type information module
Using the manufacturer approved
diagnostic system, complete a CAN
network integrity test. Refer to the
electrical circuit diagrams and check
the CAN network between the
restraints control module and the seat
module
Check the restraints control module for
related DTCs and refer to the relevant
DTC index
U0155- Lost Communication No sub type information Refer to the electrical circuit diagrams
00 With Instrument and check the power and ground
Panel Cluster (IPC) connections to the module. Using the
Control Module - No manufacturer approved diagnostic
sub type information system, complete a CAN network
integrity test. Refer to the electrical
circuit diagrams and check the CAN
network between the Instrument
Cluster and Seat Module

U0199- Lost Communication No sub type information Refer to the electrical circuit diagrams
00 With "Door Control and check the power and ground
Module A" - No sub connections to the module. Using the
type information manufacturer approved diagnostic
system, complete a CAN network
integrity test. Refer to the electrical
circuit diagrams and check the CAN
network between the Driver Door
Module and Seat Module

U024B- Lost Communication No sub type information Refer to the electrical circuit diagrams
00 With Seat Control and check the power and ground
Module G - No sub connections to the module. Refer to the
type information electrical circuit diagrams and check
the LIN network between the
Passenger Front Massage Seat Module
and Drivers Seat Module

U0300- Software No sub type information Check the module configuration using
00 Incompatibility - No the approved diagnostic system. Check
sub type information that the module software versions are
the latest release and update as
necessary

U1A14- CAN Initialization Internal electronic failure Suspect the driver seat module, check
49 Failure - Internal and install a new module as required,
electronic failure refer to the Warranty Policy and
Procedures manual if a module is
suspect

U1A4C- Build / End of Line Vehicle configuration Check the module configuration using
00 mode Active - No incorrect the approved diagnostic system
sub type information
U2100- Initial Configuration Car Configuration Data not Install car config to Central Junction
00 Not Complete - No loaded (Central Junction Box Box. Clear DTC and retest systems
sub type information installed to vehicle and not
initialized)
Internal Central Junction Box
failure

U2101- Control Module Car Configuration Data Carry out the new module software
00 Configuration transmitted over CAN does installation procedure
Incompatible - No not match seat control
sub type information module internal config
U3000- Control Module - Internal electronic failure Renew the Control module. Refer to
49 Internal electronic Internal RAM/ROM error the Warranty Policy and Procedures
failure manual if a module is suspect

U3001- Control Module Event information DTC for information only. Clear the
46 Improper Shutdown - DTC and retest. If the problem persists,
Calibration/parameter renew the module. Refer to the
memory failure warranty policies and procedures
before renewing a control module

U3002- Vehicle Identification Invalid serial data received Configure the module using the
81 Number - Invalid manufacturers approved diagnostic
serial data received system

U3003- Battery Voltage - Battery voltage below Check vehicle battery and charging
16 Circuit voltage below threshold (8 volts) system. Refer to the relevant section in
threshold the workshop manual. Refer to the
electrical circuit diagrams and check
the power supply circuits to the module

U3003- Battery Voltage - Battery voltage above Check vehicle battery and charging
17 Circuit voltage above threshold system. Refer to the relevant section in
threshold the workshop manual. Refer to the
electrical circuit diagrams and check
the power supply circuits to the module
Published: 26-Jan-2021

2012.0 XF (X250), 100-00

General Information

Diagnostic Trouble Code Index - DTC: Electric


Parking Brake (PBM) (G1426783)
DESCRIPTION AND OPERATION
Parking Brake Module (PBM)
CAUTION:

Diagnosis by substitution from a donor vehicle is NOT acceptable. Substitution of control modules does not
guarantee confirmation of a fault, and may also cause additional faults in the vehicle being tested and/or the donor
vehicle

NOTES:

If the control module or a component is at fault and the vehicle remains under manufacturer warranty, refer to
the warranty policy and procedures manual, or determine if any prior approval program is in operation, prior
to the installation of a new module/component

Generic scan tools may not read the codes listed, or may read only 5-digit codes. Match the 5 digits from the
scan tool to the first 5 digits of the 7-digit code listed to identify the fault (the last 2 digits give extra
information read by the manufacturer-approved diagnostic system)

When performing voltage or resistance tests, always use a digital multimeter accurate to three decimal places
and with a current calibration certificate. When testing resistance, always take the resistance of the digital
multimeter leads into account

Check and rectify basic faults before beginning diagnostic routines involving pinpoint tests

Inspect connectors for signs of water ingress, and pins for damage and/or corrosion

If diagnostic trouble codes are recorded and, after performing the pinpoint tests, a fault is not present, an
intermittent concern may be the cause. Always check for loose connections and corroded terminals

Where an 'on demand self-test' is referred to, this can be accessed through the 'diagnostic trouble code monitor'
tab on the manufacturers approved diagnostic system

Check JLR claims submission system for open campaigns. Refer to the corresponding bulletins and SSM's
which may be valid for the specific customer complaint and complete the recommendations as needed.

The table below lists all diagnostic trouble codes (DTCs) that could be set in the electric park brake module, for
additional diagnosis and testing information refer to the relevant diagnosis and testing section. For additional
information, refer to: Parking Brake (206-05 Parking Brake and Actuation, Diagnosis and Testing).

DTC Description Possible Causes Action


P1536- Parking Brake Wiring harness All signals from the switch are active at the same time.
62 Switch Circuit - fault Refer to the electrical circuit diagrams and check all the
Signal compare Switch internal switch apply, release and return circuits for short circuit
failure fault or open circuit. Repair wiring harness as required
If no fault with the wiring harness the switch may have
an internal fault. Refer to the Warranty Policy and
Procedures manual if a module/component is at fault

P1536- Parking Brake System abuse NOTE:


66 Switch Circuit - Wiring harness
Signal has too fault The electric park brake system will be locked out if the
many transitions Switch internal module receives more then 30 apply/release requests within 1
/ events fault minute.

Cycle the ignition to clear the fault mode. Clear the


DTC and test the system
Refer to the electrical circuit diagrams and check all the
switch apply, release and return circuits for intermittent
short circuit or open circuit. Repair wiring harness as
required
If there are no wiring faults and the DTC resets the
switch may be at fault. Refer to the Warranty Policy
and Procedures manual if a module/component is at
fault

P1571- Brake Switch - Wiring harness The signal from the hardwired brake pedal switch does
64 Signal fault not agree with the brake status message broadcast on
plausibility Brake pedal CAN. Refer to the electrical circuit diagrams and check
failure switch fault the brake pedal switch circuits for short circuit or open
circuit. Repair wiring harness as required
If there are no wiring harness faults the switch may be
at fault. Refer to the Warranty Policy and Procedures
manual if a module/component is at fault

C1127- Position Sensor Parking brake Inspect mechanical linkages for faults/damage. Repair
31 - No Signal motor hall effect as required. Refer to the electrical circuit diagrams and
position sensor check parking brake motor hall effect position sensor
power circuit fault circuits for short, open circuit. Check and install a new
Parking brake sensor actuator as required
motor hall effect
position sensor
ground circuit
fault
Parking brake
motor hall effect
position sensor
signal circuit fault
Mechanical fault
with
sensor/actuator

C1129- Actuator engage Motor engage Complete parking brake calibration procedure. check
39 - Incorrect has current reached for mechanical failure of parking brake system
too few pulses before full apply
travel distance
Service brake
adjustment
incorrect after
brake lining
replacement
Brake cables
broken, seized,
trapped
Caliper
malfunction

C1129- Actuator engage Motor engage Complete parking brake calibration procedure. check
3A - Incorrect has current not for mechanical failure of parking brake system
too many pulses reached or
travelled too far
upon apply
Service brake
adjustment
incorrect after
brake lining
replacement
Brake cables
broken, seized,
trapped
Caliper
malfunction

C112A- Actuator Intermittent motor Check for additional motor or circuit DTCs and refer to
39 disengage - or circuit - open DTC index. check for mechanical failure of parking
Incorrect has too circuit brake
few pulses Actuator
malfunction

C1801- Motor Engage Electric park NOTE:


00 Current Reached brake cable(s)
Before Full broken, seized or After completing any mechanical service work on the electric
Apply Travel trapped park brake, the electric park brake control module must be re-
Distance - No Electric park calibrated
sub type brake actuator
information incorrectly Check the integrity of the left and right electric park
installed brake cables. Install new cable(s) as required
Service brake Check the electric park brake actuator is correctly
adjustment installed. Repair as required
incorrect after Check the rear brake linings for correct adjustment.
brake lining Repair as required
replacement If the fault persists, install a new electric park brake
Electric park actuator as required
brake actuator
internal failure

C1802- Motor Engage Rear brake NOTE:


00 Current Not caliper(s) seized
Reached or Electric park After completing any mechanical service work on the electric
Traveled Too brake cable(s) park brake, the electric park brake control module must be re-
Far Upon Apply broken or calibrated
- No sub type disconnected
information Electric park Check the rear service brake caliper(s) for correct
brake calibration installation and operation. Repair as required
not completed Check the integrity of the left and right electric park
after installing a brake cables. Install new cable(s) as required
new actuator Re-calibrate the park brake, refer to the calibration
Electric park procedure
brake actuator If the fault persists, install a new electric park brake
actuator as required
internal failure

C1D00- Park brake apply Connector fault - Refer to electrical circuit diagrams and check the switch
11 switch - Circuit bent, loose or primary and secondary apply circuits for short to
short to ground corroded pin(s) ground. Repair circuit faults or install a new switch as
Harness fault - required
short to ground
Switch fault

C1D00- Park brake apply Connector fault - Refer to electrical circuit diagrams and check the switch
15 switch circuit - bent, loose or primary and secondary apply circuits for short to power
Circuit short to corroded pin(s) or open circuit. Repair circuit faults or install a new
battery or open Harness fault - switch as required
short to power or
open circuit
Switch fault

C1D00- Park brake apply Connector fault - Refer to the electrical circuit diagrams and test primary
1C switch - Voltage bent, loose or parking brake apply switch circuits for short to ground
out of range corroded pin(s) Check and install a new switch as required
Harness fault -
low resistance to
ground
Switch fault

C1D00- Park brake apply Connector fault - Apply switch active then release switch active, refer to
62 switch - Signal bent, loose or electrical circuit diagrams and check apply/release
compare failure corroded pin(s) switch circuits
Harness fault Check and install a new switch as required
Switch fault

C1D00- Park brake apply Connector fault - Refer to the electrical circuit diagrams and test parking
64 switch - Signal bent, loose or brake primary and secondary apply circuits
plausibility corroded pin(s) Check and install a new switch as required
failure Harness fault -
primary or
secondary apply
circuit
Switch fault

C1D01- Park brake Connector fault - Refer to the electrical circuit diagrams and test park
11 release switch - bent, loose or brake primary and secondary circuit for short to ground
Circuit short to corroded pin(s) Check and install a new switch as required
ground Harness fault -
short to ground
Switch fault

C1D01- Park brake Connector fault - Refer to the electrical circuit diagrams and test parking
15 release switch - bent, loose or brake primary and secondary release circuits for open
Circuit short to corroded pin(s) circuits or short to power
battery or open Harness fault - Check and install a new switch as required
open circuit
Harness fault -
short to power
Switch fault
C1D01- Park brake Connector fault - Refer to electrical circuit diagrams and test park brake
1C release switch - bent, loose or switch primary and secondary switch circuits for low
Voltage out of corroded pin(s) resistance to ground
range Harness fault - Check and install a new switch as required
low resistance to
ground
Switch fault

C1D01- Park brake Connector fault - Release switch active then apply switch active. Refer to
62 release switch - bent, loose or electrical circuit diagrams and check switch circuits for
Signal compare corroded pin(s) open circuits or shorts. Repair circuit or replace switch
failure Harness fault as required
Switch fault

C1D01- Park brake Connector fault - Primary and secondary release switch inputs signals do
64 release switch - bent, loose or not match. Check connectors for damaged pins, Refer
Signal corroded pin(s) to electrical circuit diagrams and check switch circuits
plausibility Harness fault for open circuits or shorts. Repair circuit or replace
failure Switch fault switch as required

B1142- Ignition Status 1 The hard wired Refer to electrical circuit diagrams and check parking
64 - Signal ignition status brake module ignition power supply for short to
plausibility signal does not ground, open circuit
failure agree with CAN
messages. Ignition
power supply is
detected open
circuit when
ignition status is
set to 'ON'

U0001- High Speed CAN Bus circuit Refer to the electrical circuit diagrams and check the
87 CAN fault power and ground connections to the module. Using the
communication Power distribution manufacturer approved diagnostic system, complete a
bus - Missing fault CAN network integrity test. Refer to the electrical
message circuit diagrams and check the CAN network

U0001- High speed CAN Bus circuit Refer to the electrical circuit diagrams and check the
88 CAN fault power and ground connections to the module. Using the
communication Power distribution manufacturer approved diagnostic system, complete a
Bus - Bus off fault CAN network integrity test. Refer to the electrical
circuit diagrams and check the CAN network

U0100- Lost Engine control Check the Engine Control Module for related DTCs and
00 Communication module / system refer to the relevant DTC index
with ECM/PCM fault Refer to the electrical circuit diagrams and check the
A - No sub type Wiring harness power and ground connections to the module. Using the
information fault manufacturer approved diagnostic system, complete a
CAN network integrity test. Refer to the electrical
circuit diagrams and check the CAN network

U0103- Lost Gear shift control Check the Gear Shift Control Module for related DTCs
00 communication module / system and refer to the relevant DTC index
With Gear Shift fault Refer to the electrical circuit diagrams and check the
Module A - No Wiring harness power and ground connections to the module. Using the
sub type fault manufacturer approved diagnostic system, complete a
information CAN network integrity test. Refer to the electrical
circuit diagrams and check the CAN network

U0104- Lost Cruise control Check the cruise control module for related DTCs and
00 communication module / system refer to the relevant DTC index
With Cruise fault Refer to the electrical circuit diagrams and check the
Control Module Wiring harness power and ground connections to the module. Using the
A - No sub type fault manufacturer approved diagnostic system, complete a
information CAN network integrity test. Refer to the electrical
circuit diagrams and check the CAN network

U0121- Lost Anti-Lock Check the Anti-Lock Braking System Control Module
00 communication Braking System for related DTCs and refer to the relevant DTC index
with Anti-Lock control module / Refer to the electrical circuit diagrams and check the
Braking System system fault power and ground connections to the module. Using the
(ABS) Control Wiring harness manufacturer approved diagnostic system, complete a
Module - No sub fault CAN network integrity test. Refer to the electrical
type information circuit diagrams and check the CAN network

U0155- Lost Instrument Cluster Check the Instrument Cluster for related DTCs and
00 Communication / system fault refer to the relevant DTC index
With Instrument Wiring harness Refer to the electrical circuit diagrams and check the
Panel Cluster fault power and ground connections to the module. Using the
(IPC) Control manufacturer approved diagnostic system, complete a
Module - No sub CAN network integrity test. Refer to the electrical
type information circuit diagrams and check the CAN network

U0300- Internal Control Car configuration Check all control modules for related DTCs and refer to
00 Module file stored in Park the relevant DTC index
Software Brake Module Check the components installed on the vehicle were
Incompatibility - does not match installed by the factory or a retailer / authorized repairer
No sub type the master car Install the original components or a new one as required
information configuration file
Master car
configuration file
not being
transmitted by
master control
module

U0401- Invalid Data Invalid message Check the Engine Control Module for related DTCs and
00 Received From from the Engine refer to the relevant DTC index
ECM/PCM - No Control Module
sub type
information
U0404- Invalid Data Invalid message Check the Gear Shift Control Module for related DTCs
00 Received From from the gear shift and refer to the relevant DTC index
Gear Shift control module
Control Module
A - No sub type
information
U0415- Invalid Data Invalid message NOTE:
00 Received From from the anti-lock
Anti-Lock Braking system This DTC may be stored even though no fault condition is
Braking System module present and should be ignored unless the customer has
(ABS) Control reported a electronic park brake concern. Clear the DTC and
Module - No sub retest. Verify the customer concern prior to diagnosis
type information
Check the Anti-Lock Braking System Control Module
for related DTCs and refer to the relevant DTC index

U0422- Invalid data Invalid message Check the Central Junction Box for related DTCs and
00 received from from the Central refer to the relevant DTC index
Central Junction Junction Box
Box - No sub
type information
U0423- Invalid Data Invalid message Check the Instrument Cluster for related DTCs and
00 Received From from the refer to the relevant DTC index
Instrument Panel instrument panel
Control Module control module
- No sub type
information
U0433- Invalid Data Incorrect apply NOTE:
64 Received From request from the
Cruise Control cruise control The Park Brake Module has received a request to apply the
Front Distance module when the park brake from the Adaptive cruise control module but the
Range Sensor - conditions were conditions were not correct for the apply to take place. For
Signal not correct example the vehicle was moving. The module will ignore the
plausibility request but this DTC is set for safety reference
failure
Check the cruise control module for related DTCs and
refer to the relevant DTC index

U2001- Reduced System Invalid or missing NOTE:


68 Function - Event message from
information Anti-Lock There has been invalid or missing data detected from the
Braking System Anti-Lock Brake System Control Module. This DTC may be
with ignition OFF set if the ignition is switched off with the vehicle still moving.
and vehicle speed This DTC will never be recorded as confirmed and is stored
> 3Kph for historical analysis only

Check the cruise control module for related DTCs and


refer to the relevant DTC index

U2005- Vehicle Speed - Implausible speed NOTE:


64 Signal message from the
implausibility Anti-Lock Implausible speed is defined as passing from high speed
failure Braking System dynamic mode to static mode without passing through low
control module speed dynamic mode

Check the Anti-Lock Braking System Control Module


for related DTCs and refer to the relevant DTC index

U200D- Control Module Actuator FET Refer to electrical wiring diagrams and check the
4B Output Power A circuit over actuator circuit for low resistance. Repair circuit faults
- Over current / over or install a new actuator as required
temperature temperature

U2011- Motor - Circuit Electric park Refer to electrical wiring diagrams and check the
11 short to ground brake motor actuator circuit for short to ground. Repair circuit faults
output short to or install a new actuator as required
ground
U2011- Motor - Circuit Electric park Refer to electrical wiring diagrams and check the
12 short to battery brake motor actuator circuit for short to power. Repair circuit faults
output short to or install a new actuator as required
power

U2011- Motor - Circuit Electric park Refer to electrical wiring diagrams and check the
13 open brake motor actuator circuit for open circuit. Repair circuit faults or
output open install a new actuator as required
circuit

U3000- Control Module Defective ECU Lost communication with secondary micro processor,
47 - check power and ground connections to module. Clear
Watchdog/safety DTC, perform battery reset and retest system. If DTC
micro controller reoccurs the parking brake control module may be at
failure fault
Refer to the Warranty Policy and Procedures manual if
a module/component is at fault

U3002- Vehicle The Park Brake Check and install the original, or a new Park Brake
81 Identification Module has Module
Number (VIN) - previously been Refer to the Warranty Policy and Procedures manual if
Invalid serial installed to a module/component is at fault
number another vehicle

U3003- Battery Voltage Power distribution There is a difference of more than 2 volts between the
62 - Signal fault power supply to the parking brake module and the
compare failure Wiring harness battery voltage value broadcast on CAN. Check other
fault control modules for battery voltage related DTCs. Refer
to the electrical circuit diagrams and check the power
and ground supply circuits to the Park Brake Module.
Repair wiring as required, clear the DTC and retest the
system

U3006- Control Module ECU logic voltage Refer to electrical circuit diagrams, check power
16 Input Power A - is high (over 18 supplies and ground connections to the park brake
Circuit voltage volts for 40mS) control module. Check battery voltage and charging
below threshold Wiring harness system. Repair wiring harness or charging system as
fault required, clear DTC, perform battery reset. Retest
Charging system system
fault

U3006- Control Module ECU logic voltage Refer to electrical circuit diagrams, check power
17 Input Power A - is low (below 8 supplies and ground connections to the park brake
Circuit voltage volts for 2000mS) control module. Check battery voltage and charging
above threshold Wiring harness system. Repair wiring harness or charging system as
fault required, clear DTC, perform battery reset. Retest
Charging system system
fault

U3007- Control Module Connector fault - Refer to electrical circuit diagrams, check Park Brake
14 Input Power B - bent, loose or Module high power feed circuit for open circuits or
Circuit short to corroded pin(s) short to ground. Repair wiring harness as required, clear
ground or open Harness fault DTC
Published: 26-Oct-2018

2012.0 XF (X250), 100-00

General Information

Diagnostic Trouble Code Index - DTC: Engine


Control Module - 2.2L I4 - DW12C (PCM) (G2046505)
DESCRIPTION AND OPERATION
Engine Control Module 2.2L - TD4 - DW12c
CAUTION:

Diagnosis by substitution from a donor vehicle is NOT acceptable. Substitution of control modules does not
guarantee confirmation of a fault, and may also cause additional faults in the vehicle being tested and/or the donor
vehicle

NOTES:

If the control module or a component is suspect and the vehicle remains under manufacturer warranty, refer to
the warranty policy and procedures manual, or determine if any prior approval programme is in operation,
prior to the installation of a new module/component.

Generic scan tools may not read the codes listed, or may read only 5-digit codes. Match the 5 digits from the
scan tool to the first 5 digits of the 7-digit code listed to identify the fault (the last 2 digits give extra
information read by the manufacturer-approved diagnostic system)

When performing voltage or resistance tests, always use a digital multimeter that has the resolution ability to
view 3 decimal places. For example, on the 2 volts range can measure 1mV or 2 K Ohm range can measure 1
Ohm. When testing resistance always take the resistance of the digital multimeter leads into account

Check and rectify basic faults before beginning diagnostic routines involving pinpoint tests

Inspect connectors for signs of water ingress, and pins for damage and/or corrosion

If diagnostic trouble codes are recorded and, after performing the pinpoint tests, a fault is not present, an
intermittent concern may be the cause. Always check for loose connections and corroded terminals

Where an 'on demand self-test' is referred to, this can be accessed via the 'diagnostic trouble code monitor' tab
on the manufacturers approved diagnostic system

Check DDW for open campaigns. Refer to the corresponding bulletins and SSMs which may be valid for the
specific customer complaint and carry out the recommendations as required

The table below lists all Diagnostic Trouble Codes (DTCs) that could be logged in the Engine Control Module 2.2L
- I4 - DW12C, for additional Diagnosis and Testing information refer to the relevant Diagnosis and Testing Section.
For additional information, refer to:

Electronic Engine Controls (303-14B Electronic Engine Controls - TD4 2.2L Diesel, Diagnosis and Testing),
Diesel Particulate Filter (309-00A Exhaust System - TD4 2.2L Diesel, Diagnosis and Testing).

DTC Description Possible Causes Action


B101E- Air Conditioning Mode CAN harness failure Using the Jaguar Land Rover Approved
87 Switch - Missing message between engine Diagnostic Equipment check the heating
control module and ventilation air conditioning control
heating ventilation air module for related DTCs and refer to the
conditioning control relevant DTC index
module Using the Jaguar Land Rover Approved
Diagnostic Equipment check the central
junction box for related DTCs and refer
to the relevant DTC index
Refer to electrical circuit diagrams and
check the CAN harness between heating
ventilation air conditioning control
module, central junction box and engine
control module

B10A2- Crash Input - Signal low The engine control Using the Jaguar Land Rover Approved
32 time < minimum module detected the Diagnostic Equipment check the
low pulse is too restraints control module for related
narrow with respect to DTCs and refer to the relevant DTC
time index
Restraints control Using the Jaguar Land Rover Approved
module fault Diagnostic Equipment check the central
Restraints control junction box for related DTCs and refer
module crash input to the relevant DTC index
circuit short circuit to Refer to electrical circuit diagrams and
ground, short circuit to check the restraints control module
power, open circuit circuit for short circuit to ground, short
circuit to power, open circuit including
intermittent faults. This circuit is a
single wire which connects the restraints
control module to the central junction
box and the engine control module

B10A2- Crash Input - Signal high The engine control Using the Jaguar Land Rover Approved
35 time > maximum module detects that the Diagnostic Equipment check the
signal high time is restraints control module for related
greater than the DTCs and refer to the relevant DTC
maximum value index
Restraints control Using the Jaguar Land Rover Approved
module fault Diagnostic Equipment check the central
Restraints control junction box for related DTCs and refer
module crash input to the relevant DTC index
circuit short circuit to Refer to electrical circuit diagrams and
ground, short circuit to check the restraints control module
power, open circuit circuit for short circuit to ground, short
circuit to power, open circuit including
intermittent faults. This circuit is a
single wire which connects the restraints
control module to the central junction
box and the engine control module

B10A2- Crash Input - Signal The engine control Using the Jaguar Land Rover Approved
36 frequency too low module detected Diagnostic Equipment check the
excessive duration for restraints control module for related
one cycle of the output DTCs and refer to the relevant DTC
across a specified index
sample size Using the Jaguar Land Rover Approved
Restraints control Diagnostic Equipment check the central
module fault junction box for related DTCs and refer
Restraints control to the relevant DTC index
module crash input Refer to electrical circuit diagrams and
circuit short circuit to check the restraints control module
ground, short circuit to circuit for short circuit to ground, short
power, open circuit circuit to power, open circuit including
intermittent faults. This circuit is a
single wire which connects the restraints
control module to the central junction
box and the engine control module

B10A2- Crash Input - Signal The engine control Using the Jaguar Land Rover Approved
37 frequency too high module detected Diagnostic Equipment check the
insufficient duration restraints control module for related
for one cycle of the DTCs and refer to the relevant DTC
output across a index
specified sample size Using the Jaguar Land Rover Approved
Restraints control Diagnostic Equipment check the central
module fault junction box for related DTCs and refer
Restraints control to the relevant DTC index
module crash input Refer to electrical circuit diagrams and
circuit short circuit to check the restraints control module
ground, short circuit to circuit for short circuit to ground, short
power, open circuit circuit to power, open circuit including
intermittent faults. This circuit is a
single wire which connects the restraints
control module to the central junction
box and the engine control module

B11EE- A/C Compressor - Circuit The engine control Refer to the electrical circuit diagrams
11 short to ground module has detected a and check the air conditioning
ground measurement compressor circuit for short circuit to
for a period longer ground
than expected or has Refer to the electrical circuit diagrams
detected a ground and check air conditioning relay output
measurement when circuit between engine control module
another value was and battery junction box for short circuit
expected to ground
Air conditioning
compressor output
signal short circuit to
ground
Air conditioning relay
output circuit between
engine control module
and battery junction
box short circuit to
ground

B11EE- A/C Compressor - Circuit The engine control Refer to the electrical circuit diagrams
12 short to battery module has detected a and check the air conditioning
vehicle power compressor circuit for short circuit to
measurement for a power
period longer than Refer to the electrical circuit diagrams
expected or has and check air conditioning relay output
detected a vehicle circuit between engine control module
power measurement and battery junction box for short circuit
when another value to power
was expected
Air conditioning
compressor output
signal short circuit to
power
Air conditioning relay
output circuit between
engine control module
and battery junction
box short circuit to
power

B11EE- A/C Compressor - Circuit The engine control Refer to the electrical circuit diagrams
13 open module has and check the air conditioning
determined an open compressor circuit for open circuit, high
circuit via lack of bias resistance
voltage, low current
flow, no change in the
state of an input in
response to an output
Air conditioning
compressor output
signal open circuit,
high resistance

B11EE- A/C Compressor - Over The engine control Refer to the electrical circuit diagrams
4B temperature module detected an and check air conditioning relay output
internal temperature circuit between engine control module
above the expected and battery junction box for short circuit
range to power
Air conditioning relay
output circuit between
engine control module
and battery junction
box short circuit to
power

B11D9- Vehicle Battery - No sub Harness fault This DTC is set when the battery
00 type information Battery fault monitoring system fails a diagnostic
Battery monitoring check
system module fault Refer to the battery care manual and
verify that the vehicle battery is fully
charged and serviceable before
continuing with further diagnostic tests
Refer to the electrical circuit diagrams
and check the connections between the
battery and the battery monitoring
module are clean and secure
Ensure that full battery voltage is
present on the monitor line pin at the
battery monitoring system module
connector. Ensure the battery ground
connection is clean and secure
Check the LIN bus connections to the
battery monitoring system module.
Check LIN bus integrity. If no fault
found in wiring harness check and
install a new battery monitoring system
module

B11DB- Battery Monitoring Harness fault This DTC is set when the engine control
87 Module "A" - Missing Battery monitoring module has lost communication with the
message system module fault battery monitoring system module
Refer to the battery care manual and
verify that the vehicle battery is fully
charged and serviceable before
continuing with further diagnostic tests
Refer to the electrical circuit diagrams
and check the connections between the
battery and the battery monitoring
module are clean and secure
Ensure that full battery voltage is
present on the monitor line pin at the
battery monitoring system module
connector. Ensure the battery ground
connection is clean and secure
Check the LIN bus connections to the
battery monitoring system module.
Check LIN bus integrity. If no fault
found in wiring harness check and
install a new battery monitoring system
module

B1206- Crash Occurred - Event This DTC is set if the Using the Jaguar Land Rover Approved
68 information restraints control Diagnostic Equipment check the
module has deployed restraints control module for DTCs and
the restraints systems refer to the relevant DTC index
following activation of
the crash sensors
Event information.
The engine control
module has received a
crash signal from the
restraints control
module

B1B71- Evaporator Temperature CAN harness failure Using the Jaguar Land Rover Approved
87 Sensor - Missing message between engine Diagnostic Equipment check the heating
control module and ventilation air conditioning control
heating ventilation air module for related DTCs and refer to the
conditioning control relevant DTC index
module Using the Jaguar Land Rover Approved
Diagnostic Equipment check the central
junction box for related DTCs and refer
to the relevant DTC index
Refer to electrical circuit diagrams and
check the CAN harness between heating
ventilation air conditioning control
module, central junction box and engine
control module

P0030- HO2S Heater Control The engine control Refer to the electrical circuit diagrams
11 Circuit (Bank 1, Sensor 1) module has detected a and check pre catalyst heated oxygen
- Circuit short to ground ground measurement sensor heater control circuit for short
for a period longer circuit to ground
than expected or has Check and install a new pre catalyst
detected a ground heated oxygen sensor as required
measurement when
another value was
expected
Pre catalyst heated
oxygen sensor heater
control circuit short
circuit to ground
Pre catalyst heated
oxygen sensor failure

P0030- HO2S Heater Control The engine control Refer to the electrical circuit diagrams
12 Circuit (Bank 1, Sensor 1) module has detected a and check pre catalyst heated oxygen
- Circuit short to battery vehicle power sensor heater control circuit for short
measurement for a circuit to power
period longer than Check and install a new pre catalyst
expected or has heated oxygen sensor as required
detected a vehicle
power measurement
when another value
was expected
Pre catalyst heated
oxygen sensor heater
control circuit short
circuit to power
Pre catalyst heated
oxygen sensor failure

P0030- HO2S Heater Control The engine control Refer to the electrical circuit diagrams
13 Circuit (Bank 1, Sensor 1) module has and check the pre catalyst heated
- Circuit open determined an open oxygen sensor heater control circuit for
circuit via lack of bias high resistance, open circuit
voltage, low current Check and install a new pre catalyst
flow, no change in the heated oxygen sensor as required
state of an input in
response to an output
Pre catalyst heated
oxygen sensor heater
control circuit high
resistance, open circuit
Pre catalyst heated
oxygen sensor failure

P0030- HO2S Heater Control The engine control Refer to the electrical circuit diagrams
4B Circuit (Bank 1, Sensor 1) module detected an and check the pre catalyst heated
- Over temperature internal temperature oxygen sensor heater control circuit for
above the expected short circuit to power
range Check and install a new pre catalyst
Pre catalyst heated heated oxygen sensor as required
oxygen sensor heater
control circuit short
circuit to power
Pre catalyst heated
oxygen sensor failure
P0046- Turbocharger/Supercharger The engine control Refer to the electrical circuit diagrams
16 Boost Control A Circuit module measured a and check the variable geometry turbine
Range/Performance - voltage below a vane actuator circuit for short circuit to
Circuit voltage below specified range but not ground, open circuit, high resistance
threshold necessarily a short Using the Jaguar Land Rover Approved
circuit to ground Diagnostic Equipment perform routine -
Variable geometry Inline diagnostic unit 2 diagnostic test -
turbine vane actuator Turbocharger
circuit, short circuit to Check and install a new variable
ground, open circuit, geometry turbine vane actuator as
high resistance required
Variable geometry
turbine vane actuator
failure

P0046- Turbocharger/Supercharger The engine control Refer to the electrical circuit diagrams
19 Boost Control A Circuit module has measured and check the variable geometry turbine
Range/Performance - current flow above a vane actuator circuit, for short circuit to
Circuit current above specified range ground, short circuit to power
threshold Variable geometry Using the Jaguar Land Rover Approved
turbine vane actuator Diagnostic Equipment perform routine -
circuit, short circuit to Inline diagnostic unit 2 diagnostic test -
ground, short circuit to Turbocharger
power Check and install a new variable
Variable geometry geometry turbine vane actuator as
turbine vane actuator required
failure

P0046- Turbocharger/Supercharger Variable geometry Refer to the electrical circuit diagrams


1D Boost Control A Circuit turbine vane actuator and check the variable geometry turbine
Range/Performance - circuit, short circuit to vane actuator circuit, for short circuit to
Circuit current out of range ground, short circuit to ground, short circuit to power, open
power, open circuit, circuit, high resistance
high resistance Using the Jaguar Land Rover Approved
Variable geometry Diagnostic Equipment perform routine -
turbine vane actuator Inline diagnostic unit 2 diagnostic test -
failure Turbocharger
Check and install a new variable
geometry turbine vane actuator as
required

P0046- Turbocharger/Supercharger The engine control Refer to the electrical circuit diagrams
4B Boost Control A Circuit module detected an and check the variable geometry turbine
Range/Performance - Over internal temperature vane actuator circuit, for short circuit to
temperature above the expected ground, short circuit to power
range Using the Jaguar Land Rover Approved
Variable geometry Diagnostic Equipment perform routine -
turbine vane actuator Inline diagnostic unit 2 diagnostic test -
circuit, short circuit to Turbocharger
ground, short circuit to Check and install a new variable
power geometry turbine vane actuator as
Variable geometry required
turbine vane actuator
failure
P0046- Turbocharger/Supercharger The engine control Refer to the electrical circuit diagrams
77 Boost Control A Circuit module is unable to and check the variable geometry turbine
Range/Performance - command a motor, vane actuator circuit, for short circuit to
Commanded position not solenoid or relay, to ground, short circuit to power
reachable move a piece of Using the Jaguar Land Rover Approved
equipment to the Diagnostic Equipment perform routine -
commanded position Inline diagnostic unit 2 diagnostic test -
either due to a failure Turbocharger
in the actuator or its Check and install a new variable
mechanical geometry turbine vane actuator as
environment required
Variable geometry
turbine vane actuator
circuit, short circuit to
ground, short circuit to
power
Variable geometry
turbine vane actuator
failure

P0047- Turbocharger/Supercharger Variable geometry Refer to the electrical circuit diagrams


00 Boost Control A Circuit turbine vane actuator and check the variable geometry turbine
Low - No sub type circuit, short circuit to vane actuator circuit, for short circuit to
information ground, open circuit, ground, open circuit, high resistance
high resistance Using the Jaguar Land Rover Approved
Variable geometry Diagnostic Equipment perform routine -
turbine vane actuator Inline diagnostic unit 2 diagnostic test -
failure Turbocharger
Check and install a new variable
geometry turbine vane actuator as
required

P0047- Turbocharger/Supercharger The engine control Refer to the electrical circuit diagrams
11 Boost Control A Circuit module has detected a and check the variable geometry turbine
Low - Circuit short to ground measurement vane actuator circuit, for short circuit to
ground for a period longer ground
than expected or has Using the Jaguar Land Rover Approved
detected a ground Diagnostic Equipment perform routine -
measurement when Inline diagnostic unit 2 diagnostic test -
another value was Turbocharger
expected Check and install a new variable
Variable geometry geometry turbine vane actuator as
turbine vane actuator required
circuit, short circuit to
ground
Variable geometry
turbine vane actuator
failure

P0047- Turbocharger/Supercharger The engine control NOTE:


77 Boost Control A Circuit module is unable to
Low - Commanded command a motor, Using the Jaguar Land Rover Approved
position not reachable solenoid or relay, to Diagnostic Equipment perform the (Turbo,
move a piece of EGR and air path dynamic test) routine
equipment to the
commanded position Refer to the electrical circuit diagrams
either due to a failure and check the variable geometry turbine
in the actuator or its vane actuator circuit, for short circuit to
mechanical ground, open circuit, high resistance
environment Using the Jaguar Land Rover Approved
Variable geometry Diagnostic Equipment perform routine -
turbine vane actuator Inline diagnostic unit 2 diagnostic test -
circuit, short circuit to Turbocharger
ground, open circuit, Check and install a new variable
high resistance geometry turbine vane actuator as
Variable geometry required
turbine vane actuator
stuck open

P0048- Turbocharger/Supercharger Variable geometry Refer to the electrical circuit diagrams


00 Boost Control A Circuit turbine vane actuator and check the variable geometry turbine
High - No sub type circuit, short circuit to vane actuator circuit, for short circuit to
information power power
Variable geometry Using the Jaguar Land Rover Approved
turbine vane actuator Diagnostic Equipment perform routine -
failure Inline diagnostic unit 2 diagnostic test -
Turbocharger
Check and install a new variable
geometry turbine vane actuator as
required

P0048- Turbocharger/Supercharger The engine control Refer to the electrical circuit diagrams
12 Boost Control A Circuit module has detected a and check the variable geometry turbine
High - Circuit short to vehicle power vane actuator circuit, for short circuit to
battery measurement for a power
period longer than Using the Jaguar Land Rover Approved
expected or has Diagnostic Equipment perform routine -
detected a vehicle Inline diagnostic unit 2 diagnostic test -
power measurement Turbocharger
when another value Check and install a new variable
was expected geometry turbine vane actuator as
Variable geometry required
turbine vane actuator
circuit, short circuit to
power
Variable geometry
turbine vane actuator
failure

P0048- Turbocharger/Supercharger The engine control NOTE:


77 Boost Control A Circuit module is unable to
High - Commanded command a motor, Using the Jaguar Land Rover Approved
position not reachable solenoid or relay, to Diagnostic Equipment perform the (Turbo,
move a piece of EGR and air path dynamic test) routine
equipment to the
commanded position Refer to the electrical circuit diagrams
either due to a failure and check the variable geometry turbine
in the actuator or its vane actuator circuit, for short circuit to
mechanical power
environment Using the Jaguar Land Rover Approved
Variable geometry Diagnostic Equipment perform routine -
turbine vane actuator Inline diagnostic unit 2 diagnostic test -
circuit, short circuit to Turbocharger
Check and install a new variable
power
Variable geometry geometry turbine vane actuator circuit,
turbine vane actuator as required
stuck open

P006A- MAP - Mass or Volume Induction air system NOTE:


00 Air Flow Correlation - No failure
sub type information Charge air system Using the Jaguar Land Rover Approved
failure Diagnostic Equipment perform the (Turbo,
Mass air flow sensor EGR and air path dynamic test) routine
circuit short circuit to
ground, short circuit to Using the Jaguar Land Rover Approved
power, high resistance, Diagnostic Equipment check for DTCs
open circuit associated with the intake and charge
Manifold absolute airflow control actuators, refer to the
pressure sensor circuit relevant DTC index and act on those
short circuit to ground, DTCs first
short circuit to power, Refer to the workshop manual and
high resistance, open check the intake air system, charge air
circuit system, intercooler and air filter for
Mass air flow sensor leaks, blockages, restrictions and control
failure valve actuator malfunctions
Manifold absolute Refer to the electrical circuit diagrams
pressure sensor failure and check the mass air flow sensor
circuit for short circuit to ground, short
circuit to power, high resistance, open
circuit
Refer to the electrical circuit diagrams
and check the manifold absolute
pressure sensor circuit for short circuit
to ground, short circuit to power, high
resistance, open circuit
Check and install a new mass air flow
sensor as required
Check and install a new manifold
absolute pressure sensor as required

P006A- MAP - Mass or Volume The engine control Using the Jaguar Land Rover Approved
22 Air Flow Correlation - module measured a Diagnostic Equipment check for DTCs
Signal amplitude > signal voltage above a associated with the intake and charge
maximum specified range but not airflow control actuators, refer to the
necessarily a short relevant DTC index and act on those
circuit to power, gain DTCs first
too high Refer to the workshop manual and
Induction air system check the intake air system, charge air
failure system, intercooler and air filter for
Charge air system leaks, blockages, restrictions and control
failure valve actuator malfunctions
Mass air flow sensor Refer to the electrical circuit diagrams
circuit short circuit to and check the mass air flow sensor
ground, short circuit to circuit for short circuit to ground, short
power, high resistance, circuit to power, high resistance, open
open circuit circuit
Manifold absolute Refer to the electrical circuit diagrams
pressure sensor circuit and check the manifold absolute
short circuit to ground, pressure sensor circuit for short circuit
short circuit to power, to ground, short circuit to power, high
high resistance, open resistance, open circuit
circuit Check and install a new mass air flow
Mass air flow sensor sensor as required
failure Check and install a new manifold
Manifold absolute absolute pressure sensor as required
pressure sensor failure

P006C- MAP - The engine control NOTE:


92 Turbocharger/Supercharger module has detected
Inlet Pressure Correlation - that the component Using the Jaguar Land Rover Approved
Performance or incorrect performance is outside Diagnostic Equipment perform the (Turbo,
operation its expected range or EGR and air path dynamic test) routine
operating in an
incorrect way Using the Jaguar Land Rover Approved
Induction air system Diagnostic Equipment check for DTCs
failure associated with the intake and charge
Charge air system airflow control actuators, refer to the
failure relevant DTC index and act on those
Mass air flow sensor DTCs first
circuit short circuit to Refer to the workshop manual and
ground, short circuit to check the intake air system, charge air
power, high resistance, system, intercooler and air filter for
open circuit leaks, blockages, restrictions and control
Manifold absolute valve actuator malfunctions
pressure sensor circuit Refer to the electrical circuit diagrams
short circuit to ground, and check the mass air flow sensor
short circuit to power, circuit for short circuit to ground, short
high resistance, open circuit to power, high resistance, open
circuit circuit
Mass air flow sensor Refer to the electrical circuit diagrams
failure and check the manifold absolute
Manifold absolute pressure sensor circuit for short circuit
pressure sensor failure to ground, short circuit to power, high
resistance, open circuit
Check and install a new mass air flow
sensor as required
Check and install a new manifold
absolute pressure sensor as required

P0070- Ambient Air Temperature The engine control Using the Jaguar Land Rover Approved
16 Sensor Circuit - Circuit module measured a Diagnostic Equipment check datalogger
voltage below threshold voltage below a signals, Ambient Air Temperature
specified range but not Sensor Voltage (0x03BA), Ambient Air
necessarily a short Temperature (0xF446)
circuit to ground Refer to the electrical circuit diagrams
Ambient air and check the ambient air temperature
temperature sensor sensor circuit for short circuit to ground,
circuit short circuit to high resistance, open circuit. Repair
ground, high harness as required. Clear DTC and
resistance, open circuit retest
Ambient air Check and install a new ambient air
temperature sensor temperature sensor as required
failure

P0070- Ambient Air Temperature The engine control Using the Jaguar Land Rover Approved
17 Sensor Circuit - Circuit module measured a Diagnostic Equipment check datalogger
voltage above threshold voltage above a signals, Ambient Air Temperature
specified range but not Sensor Voltage (0x03BA), Ambient Air
necessarily a short Temperature (0xF446)
circuit to power Refer to the electrical circuit diagrams
Ambient air and check the ambient air temperature
temperature sensor sensor circuit for short circuit to power.
circuit short circuit to Repair harness as required. Clear DTC
power and retest
Ambient air Check and install a new ambient air
temperature sensor temperature sensor as required
failure

P007A- Charge Air Cooler The engine control NOTE:


16 Temperature Sensor module measured a
Circuit (Bank 1) - Circuit voltage below a Using the Jaguar Land Rover Approved
voltage below threshold specified range but not Diagnostic Equipment perform the (Turbo,
necessarily a short EGR and air path dynamic test) routine
circuit to ground
Charge air cooler Using the Jaguar Land Rover Approved
temperature sensor Diagnostic Equipment check datalogger
circuit short circuit to signals, Charge Air Temperature
ground, high Voltage (0x03EE), Air Charge
resistance, open circuit Temperature (0x051C).
Charge air cooler Refer to the electrical circuit diagrams
temperature sensor and check the charge air cooler
failure temperature sensor circuit for short
circuit to ground, high resistance, open
circuit
Check and install a new inlet air
temperature sensor as required

P007A- Charge Air Cooler The engine control NOTE:


17 Temperature Sensor module measured a
Circuit (Bank 1) - Circuit voltage above a Using the Jaguar Land Rover Approved
voltage above threshold specified range but not Diagnostic Equipment perform the (Turbo,
necessarily a short EGR and air path dynamic test) routine
circuit to power
Charge air cooler Using the Jaguar Land Rover Approved
temperature sensor Diagnostic Equipment check datalogger
circuit short circuit to signals, Charge Air Temperature
power Voltage (0x03EE), Air Charge
Charge air cooler Temperature (0x051C).
temperature sensor Refer to the electrical circuit diagrams
failure and check the charge air cooler
temperature sensor circuit for short
circuit to power. Repair harness as
required. Clear DTC and retest
Check and install a new charge air
cooler temperature sensor as required

P007A- Charge Air Cooler The engine control NOTE:


62 Temperature Sensor module detected
Circuit (Bank 1) - Signal failure when Using the Jaguar Land Rover Approved
compare failure comparing two or Diagnostic Equipment perform the (Turbo,
more input parameters EGR and air path dynamic test) routine
for plausibility
Charge air cooler Using the Jaguar Land Rover Approved
temperature sensor Diagnostic Equipment check datalogger
circuit short circuit to signals, Charge Air Temperature
ground, short circuit to Voltage (0x03EE), Air Charge
power, high resistance, Temperature (0x051C).
open circuit Refer to electrical circuit diagrams and
Mass air flow and check charge air cooler temperature
temperature sensor sensor circuit for short circuit to ground,
circuit short circuit to short circuit to power, high resistance,
ground, short circuit to open circuit. Repair harness as required.
power, high resistance, Clear DTC and retest
open circuit Refer to electrical circuit diagrams and
Charge air cooler check mass air flow and temperature
temperature sensor sensor circuit for short circuit to ground,
failure short circuit to power, high resistance,
open circuit. Repair harness as required.
Clear DTC and retest
Check and install a new charge air
cooler temperature sensor as required

P0087- Fuel Rail/System Pressure Low level fuel Check the fuel volume available in the
00 - Too Low - No sub type condition fuel tank is sufficient, add fuel as
information Fuel gauge sender unit required. Clear DTC and retest
sticking Check the fuel gauge sender units for
Fuel lines restricted correct operation
Fuel lines leaking Check fuel lines for restriction
Fuel pump failure Check fuel lines for leakage
Fuel rail pressure Check for fuel pump related DTCs and
sensor signal circuit refer to the relevant DTC index
short circuit to ground, Refer to the electrical circuit diagrams
short circuit to power, and check fuel rail pressure sensor
open circuit, high circuit for short circuit to ground, short
resistance circuit to power, open circuit, high
Fuel rail pressure resistance. Repair harness as required
sensor failure Check and install new fuel rail pressure
sensor as required

P0087- Fuel Rail/System Pressure The engine control Refer to the electrical circuit diagrams
16 - Too Low - Circuit module measured a and check fuel rail pressure sensor
voltage below threshold voltage below a circuit for short circuit to ground, open
specified range but not circuit, high resistance. Repair harness
necessarily a short as required. Clear DTC and retest
circuit to ground Check and install new fuel rail pressure
Fuel rail pressure sensor as required
sensor circuit, short
circuit to ground, open
circuit, high resistance
Fuel rail pressure
sensor failure

P0087- Fuel Rail/System Pressure The engine control Check fuel lines for restriction
21 - Too Low - Signal module measured a Check fuel lines for leakage
amplitude < minimum signal voltage below a Check fuel injector's for stuck open,
specified range but not leakage
necessarily a short Check for fuel pump related DTCs and
circuit to ground, gain refer to the relevant DTC index
low Refer to the electrical circuit diagrams
Fuel lines restricted and check fuel rail pressure sensor
Fuel lines leaking circuit for short circuit to ground, open
Fuel injector's stuck circuit, high resistance. Repair harness
open, leaking as required
Fuel pump failure Refer to the electrical circuit diagrams
Fuel rail pressure and check fuel pressure control valve
sensor circuit short circuit for short circuit to ground, open
circuit to ground, open circuit, high resistance. Repair harness
circuit, high resistance as required
Fuel pressure control Refer to the electrical circuit diagrams
valve circuit short and check fuel volume control valve
circuit to ground, open circuit for short circuit to ground, open
circuit, high resistance circuit, high resistance. Repair harness
Fuel volume control as required
valve circuit short Check and install new fuel rail pressure
circuit to ground, open sensor as required
circuit, high resistance Check and install new fuel pressure
Fuel rail pressure control valve as required
sensor failure Check and install new fuel volume
Fuel pressure control control valve as required
valve failure
Fuel volume control
valve failure

P0087- Fuel Rail/System Pressure The engine control Check the fuel lines for any signs of
22 - Too Low - Signal module measured a leakage, replace as required
amplitude > maximum signal voltage above a Check the fuel lines for any signs of
specified range but not damage, crimping or restrictions,
necessarily a short replace as required
circuit to power, gain Check for blocked or restricted air filter,
too high replace as required
Fuel starvation
Fuel lines leaking
Fuel lines restricted
Blocked or restricted
air filter

P0087- Fuel Rail/System Pressure Fuel starvation Check the fuel lines for any signs of
71 - Too Low - Actuator stuck Fuel lines leaking leakage, replace as required
Fuel lines restricted Check the fuel lines for any signs of
Blocked or restricted damage, crimping or restrictions,
air filter replace as required
Check for blocked or restricted air filter,
replace as required

P0088- Fuel Rail/System Pressure Fuel gauge sender unit Check the fuel gauge sender units for
00 - Too High - No sub type sticking correct operation
information Fuel rail pressure Refer to the electrical circuit diagrams
sensor signal circuit and check fuel rail pressure sensor
short circuit to power circuit for short circuit to power. Repair
Fuel rail pressure harness as required
sensor ground circuit Refer to the electrical circuit diagrams
open circuit, high and check fuel rail pressure sensor
resistance ground circuit for open circuit, high
Fuel pressure control resistance. Repair harness as required
valve circuit short Refer to the electrical circuit diagrams
circuit to power, and check fuel pressure control valve
ground, open circuit, circuit for short circuit to power,
high resistance ground, open circuit, high resistance.
Fuel volume control Repair harness as required
valve circuit short Refer to the electrical circuit diagrams
circuit to power, and check fuel volume control valve
ground, open circuit, circuit for short circuit to power,
high resistance ground, open circuit, high resistance.
Fuel rail pressure Repair harness as required
sensor failure Check and install new fuel rail pressure
Fuel pressure control sensor as required
valve failure Check and install new fuel pressure
Fuel volume control control valve as required
valve failure Check and install new fuel volume
control valve as required

P0088- Fuel Rail/System Pressure The engine control Refer to the electrical circuit diagrams
17 - Too High - Circuit module measured a and check fuel rail pressure sensor
voltage above threshold voltage above a circuit for short circuit to power
specified range but not
necessarily a short
circuit to power
Fuel rail pressure
sensor signal circuit
short circuit to power

P0089- Fuel Pressure Regulator The engine control Refer to the electrical circuit diagrams
21 Performance - Signal module measured a and check fuel pressure control valve
amplitude < minimum signal voltage below a circuit for short circuit to ground, open
specified range but not circuit. Repair harness as required
necessarily a short Refer to the electrical circuit diagrams
circuit to ground, gain and check fuel pressure control valve
low reference voltage circuit for high
Fuel pressure control resistance. Repair harness as required
valve signal circuit Check and install new fuel pressure
short circuit to ground, control valve as required
open circuit
Fuel pressure control
valve reference
voltage circuit high
resistance
Fuel pressure control
valve exceeded
tolerance threshold
Fuel pressure control
valve failure

P0089- Fuel Pressure Regulator The engine control Check fuel low pressure delivery system
22 Performance - Signal module measured a Check and install a new fuel pressure
amplitude > maximum signal voltage above a control valve as required
specified range but not
necessarily a short
circuit to power, gain
too high
Fuel low pressure
delivery system
Fuel pressure control
valve exceeded
tolerance threshold
P0090- Fuel Pressure Regulator 1 The engine control Using the Jaguar Land Rover Approved
13 Control Circuit/Open - module has Diagnostic Equipment check datalogger
Circuit open determined an open signals, Fuel Pressure Relief Control
circuit via lack of bias Valve Duty Cycle (0x03C3)
voltage, low current Refer to the electrical circuit diagrams
flow, no change in the and check the fuel pressure control
state of an input in valve circuit for high resistance, open
response to an output circuit. Repair harness as required. Clear
Fuel pressure control DTC and retest
valve circuit, open Check and install a new fuel pressure
circuit, high resistance control valve as required
Fuel pressure control
valve failure

P0090- Fuel Pressure Regulator 1 The engine control Using the Jaguar Land Rover Approved
4B Control Circuit/Open - module detected an Diagnostic Equipment check datalogger
Over temperature internal temperature signals, Fuel Pressure Relief Control
above the expected Valve Duty Cycle (0x03C3)
range Refer to the electrical circuit diagrams
Fuel pressure control and check the fuel pressure control
valve circuit, short valve circuit for short circuit to power,
circuit to power, high high resistance. Repair harness as
resistance required. Clear DTC and retest
Fuel pressure control Check and install a new fuel pressure
valve failure control valve as required

P0091- Fuel Pressure Regulator 1 The engine control Using the Jaguar Land Rover Approved
11 Control Circuit Low - module has detected a Diagnostic Equipment check datalogger
Circuit short to ground ground measurement signals, Fuel Pressure Relief Control
for a period longer Valve Duty Cycle (0x03C3)
than expected or has Refer to the electrical circuit diagrams
detected a ground and check the fuel pressure control
measurement when valve circuit for short circuit to ground.
another value was Repair harness as required. Clear DTC
expected and retest
Fuel pressure control Check and install a new fuel pressure
valve circuit, short control valve as required
circuit to ground
Fuel pressure control
valve failure

P0092- Fuel Pressure Regulator 1 The engine control Using the Jaguar Land Rover Approved
12 Control Circuit High - module has detected a Diagnostic Equipment check datalogger
Circuit short to battery vehicle power signals, Fuel Pressure Relief Control
measurement for a Valve Duty Cycle (0x03C3)
period longer than Refer to the electrical circuit diagrams
expected or has and check the fuel pressure control
detected a vehicle valve circuit for short circuit to power.
power measurement Repair harness as required. Clear DTC
when another value and retest
was expected Check and install a new fuel pressure
Fuel pressure control control valve as required
valve circuit, short
circuit to power
Fuel pressure control
valve failure
P00BC- Mass or Volume Air Flow Airflow disruption at NOTE:
00 A Circuit sensing element of
Range/Performance - Air mass air flow sensor A Using the Jaguar Land Rover Approved
Flow Too Low - No sub Diagnostic Equipment perform the (Turbo,
type information EGR and air path dynamic test) routine

Refer to the relevant section of the


workshop manual and check the
induction system for air leaks, and
obstructions to flow. Check the
condition of the air filter and examine
the induction pipes for debris which
could disrupt air flow at the sensing
element

P00BD- Mass or Volume Air Flow Charge air system leak NOTE:
00 A Circuit
Range/Performance - Air Using the Jaguar Land Rover Approved
Flow Too High - No sub Diagnostic Equipment perform the (Turbo,
type information EGR and air path dynamic test) routine

Refer to the relevant section of the


workshop manual and check for air
leaks in the intake charge air system

P0102- Mass or Volume Air Flow Airflow disruption at NOTE:


00 A Circuit Low - No sub sensing element of
type information mass air flow sensor Using the Jaguar Land Rover Approved
Mass air flow sensor Diagnostic Equipment perform the (Turbo,
circuit short circuit to EGR and air path dynamic test) routine
ground, short circuit to
power, high resistance, Refer to the relevant section of the
open circuit workshop manual and check the
Mass air flow sensor induction system for air leaks, and
failure obstructions to flow. Check the
condition of the air filter and examine
the induction pipes for debris which
could disrupt air flow at the sensing
element
Using the Jaguar Land Rover Approved
Diagnostic Equipment check datalogger
signals, Air Flow Rate From Mass Air
Flow Sensor (0xF410)
Refer to the electrical circuit diagrams
and check mass air flow sensor for short
circuit to ground, short circuit to power,
high resistance, open circuit
Check and install a new mass air flow
sensor as required

P0103- Mass or Volume Air Flow Airflow disruption at NOTE:


00 A Circuit High - No sub sensing element of
type information mass air flow sensor Using the Jaguar Land Rover Approved
Mass air flow sensor Diagnostic Equipment perform the (Turbo,
circuit short circuit to EGR and air path dynamic test) routine
ground, short circuit to
power, high resistance, Refer to the relevant section of the
open circuit workshop manual and check the
Mass air flow sensor induction system for air leaks, and
failure obstructions to flow. Check the
condition of the air filter and examine
the induction pipes for debris which
could disrupt air flow at the sensing
element
Using the Jaguar Land Rover Approved
Diagnostic Equipment check datalogger
signals, Air Flow Rate From Mass Air
Flow Sensor (0xF410)
Refer to the electrical circuit diagrams
and check mass air flow sensor for short
circuit to ground, short circuit to power,
high resistance, open circuit
Check and install a new mass air flow
sensor as required

P0105- Manifold Absolute The engine control Refer to the workshop manual and
16 Pressure/BARO Circuit - module measured a check the manifold absolute pressure
Circuit voltage below voltage below a sensor is correctly connected to the air
threshold specified range but not intake manifold and there are no
necessarily a short blockages or air leaks preventing
circuit to ground communication of pressure changes
Charge air pressure between the manifold and the sensor
sensor blockage Using the Jaguar Land Rover Approved
Manifold absolute Diagnostic Equipment check datalogger
pressure sensor circuit signals, Corrected Intake Manifold
short circuit to ground, Absolute Pressure (0x0332), Manifold
open circuit, high Absolute Pressure Sensor Voltage
resistance (0x033C)
Manifold absolute Refer to the electrical circuit diagrams
pressure sensor failure and check the manifold absolute
pressure sensor circuit for short circuit
to ground, open circuit, high resistance.
Repair harness as required. Clear DTC
and retest
Check and install a new manifold
absolute pressure sensor as required

P0105- Manifold Absolute The engine control NOTE:


17 Pressure/BARO Circuit - module measured a
Circuit voltage above voltage above a Using the Jaguar Land Rover Approved
threshold specified range but not Diagnostic Equipment perform the (Turbo,
necessarily a short EGR and air path dynamic test) routine
circuit to power
Manifold absolute Refer to the workshop manual and
pressure sensor check the manifold absolute pressure
blockage sensor is correctly connected to the air
Manifold absolute intake manifold and there are no
pressure sensor circuit blockages or air leaks preventing
short circuit to power communication of pressure changes
Manifold absolute between the manifold and the sensor
pressure sensor failure Using the Jaguar Land Rover Approved
Diagnostic Equipment check datalogger
signals, Corrected Intake Manifold
Absolute Pressure (0x0332), Manifold
Absolute Pressure Sensor Voltage
(0x033C)
Refer to the electrical circuit diagrams
and check the manifold absolute
pressure sensor circuit for short circuit
to power. Repair harness as required.
Clear DTC and retest
Check and install a new manifold
absolute pressure sensor as required

P0107- Manifold Absolute Manifold absolute NOTE:


00 Pressure/BARO Sensor pressure sensor circuit
Low - No sub type short circuit to power, Using the Jaguar Land Rover Approved
information short circuit to ground, Diagnostic Equipment perform the (Turbo,
open circuit, high EGR and air path dynamic test) routine
resistance
Manifold absolute Using the Jaguar Land Rover Approved
pressure sensor failure Diagnostic Equipment check datalogger
signals, Corrected Intake Manifold
Absolute Pressure (0x0332), Manifold
Absolute Pressure Sensor Voltage
(0x033C)
Refer to the electrical circuit diagrams
and check the boost pressure sensor
circuit for short circuit to power,
ground, open circuit, high resistance.
Repair harness as required. Clear DTC
and retest
Check and install a new manifold
absolute pressure sensor as required

P0108- Manifold Absolute Manifold absolute NOTE:


00 Pressure/BARO Sensor pressure sensor circuit
High - No sub type short circuit to power, Using the Jaguar Land Rover Approved
information short circuit to ground, Diagnostic Equipment perform the (Turbo,
open circuit, high EGR and air path dynamic test) routine
resistance
Manifold absolute Using the Jaguar Land Rover Approved
pressure sensor failure Diagnostic Equipment check datalogger
signals, Corrected Intake Manifold
Absolute Pressure (0x0332), Manifold
Absolute Pressure Sensor Voltage
(0x033C)
Refer to the electrical circuit diagrams
and check the manifold absolute
pressure sensor circuit for short circuit
to power, ground, open circuit, high
resistance. Repair harness as required.
Clear DTC and retest
Check and install a new manifold
absolute pressure sensor as required

P0110- Intake Air Temperature The engine control Using the Jaguar Land Rover Approved
16 Sensor 1 Circuit (Bank 1) - module measured a Diagnostic Equipment check datalogger
Circuit voltage below voltage below a signals, Intake Air Temperature Sensor
threshold specified range but not (0x1279), Intake Air Temperature
necessarily a short (0xF40F)
circuit to ground Refer to the electrical circuit diagrams
Mass air flow and and check the mass air flow and
temperature sensor temperature sensor circuit for short
circuit short circuit to circuit to ground. Repair harness as
ground required. Clear DTC and retest

P0110- Intake Air Temperature The engine control NOTE:


17 Sensor 1 Circuit (Bank 1) - module measured a
Circuit voltage above voltage above a Using the Jaguar Land Rover Approved
threshold specified range but not Diagnostic Equipment perform the (Turbo,
necessarily a short EGR and air path dynamic test) routine
circuit to power
Mass air flow and Using the Jaguar Land Rover Approved
temperature sensor Diagnostic Equipment check datalogger
circuit short circuit to signals, Intake Air Temperature Sensor
power (0x1279), Intake Air Temperature
(0xF40F)
Refer to the electrical circuit diagrams
and check the mass air flow and
temperature sensor circuit for short
circuit to power. Repair harness as
required. Clear DTC and retest

P0116- Engine Coolant Engine coolant level Refer to the workshop manual and
00 Temperature Sensor 1 too low or flow failure check the engine cooling system to
Circuit Range/Performance Engine coolant ensure the coolant condition and level is
- No sub type information temperature sensor correct
circuit short circuit to Using the Jaguar Land Rover Approved
ground, short circuit to Diagnostic Equipment check datalogger
power, high resistance, signals, Engine Coolant Temperature
open circuit Sensor (0x0357), Engine Coolant
Engine coolant Temperature (0xF405)
temperature sensor Refer to the electrical circuit diagrams
failure and check the engine coolant
temperature sensor circuit for short
circuit to ground, short circuit to power,
high resistance, open circuit. Repair
harness as required. Clear DTC and
retest
Check and install a new engine coolant
temperature sensor as required

P0116- Engine Coolant The engine control Refer to the workshop manual and
16 Temperature Sensor 1 module measured a check the engine cooling system to
Circuit Range/Performance voltage below a ensure the coolant condition and level is
- Circuit voltage below specified range but not correct
threshold necessarily a short Using the Jaguar Land Rover Approved
circuit to ground Diagnostic Equipment check datalogger
Engine coolant level signals, Engine Coolant Temperature
too low or flow failure Sensor (0x0357), Engine Coolant
Engine coolant Temperature (0xF405)
temperature sensor Refer to the electrical circuit diagrams
circuit short circuit to and check the engine coolant
ground, high temperature sensor circuit for short
resistance, open circuit circuit to ground, high resistance, open
Engine coolant circuit. Repair harness as required. Clear
temperature sensor DTC and retest
failure Check and install a new engine coolant
temperature sensor as required

P0116- Engine Coolant The engine control Refer to the workshop manual and
17 Temperature Sensor 1 module measured a check the engine cooling system to
Circuit Range/Performance voltage above a ensure the coolant condition and level is
- Circuit voltage above specified range but not correct
threshold necessarily a short Using the Jaguar Land Rover Approved
circuit to power Diagnostic Equipment check datalogger
Engine coolant level signals, Engine Coolant Temperature
or flow failure Sensor (0x0357), Engine Coolant
Engine coolant Temperature (0xF405)
temperature sensor Refer to the electrical circuit diagrams
short circuit to power and check the engine coolant
Engine coolant temperature sensor circuit for short
temperature sensor circuit to power. Repair harness as
failure required. Clear DTC and retest
Check and install a new engine coolant
temperature sensor as required

P0117- Engine Coolant Engine coolant level Refer to the workshop manual and
00 Temperature Sensor 1 too low or flow failure check the engine cooling system to
Circuit Low - No sub type Engine coolant ensure the coolant condition and level is
information temperature sensor correct
circuit short circuit to Using the Jaguar Land Rover Approved
ground, high Diagnostic Equipment check datalogger
resistance, open circuit signals, Engine Coolant Temperature
Engine coolant Sensor (0x0357), Engine Coolant
temperature sensor Temperature (0xF405)
failure Refer to the electrical circuit diagrams
and check the engine coolant
temperature sensor circuit for short
circuit to ground, high resistance, open
circuit. Repair harness as required. Clear
DTC and retest
Check and install a new engine coolant
temperature sensor as required

P0118- Engine Coolant Engine coolant level Refer to the workshop manual and
00 Temperature Sensor 1 or flow failure check the engine cooling system to
Circuit High - No sub type Engine coolant ensure the coolant condition and level is
information temperature sensor correct
short circuit to power Using the Jaguar Land Rover Approved
Engine coolant Diagnostic Equipment check datalogger
temperature sensor signals, Engine Coolant Temperature
failure Sensor (0x0357), Engine Coolant
Temperature (0xF405)
Refer to the electrical circuit diagrams
and check the engine coolant
temperature sensor circuit for short
circuit to power. Repair harness as
required. Clear DTC and retest
Check and install a new engine coolant
temperature sensor as required

P0130- O2 Sensor Circuit (Bank 1 The engine control Refer to the electrical circuit diagrams
13 Sensor 1) - Circuit open module has and check the pre catalyst heated
determined an open oxygen sensor circuit for open circuit,
circuit via lack of bias high resistance
voltage, low current Check and install a new pre catalyst
flow, no change in the heated oxygen sensor as required
state of an input in
response to an output
Pre catalyst heated
oxygen sensor circuit
open circuit, high
resistance
Pre catalyst heated
oxygen sensor failure

P0130- O2 Sensor Circuit (Bank 1 The signal transitions Refer to the relevant section of the
26 Sensor 1) - Signal rate of more slowly than is workshop manual and check for and
change below threshold reasonably allowed rectify any exhaust leak between
Exhaust system leak cylinder head and catalytic converter.
Fuel control system Check pre catalyst heated oxygen sensor
fault is correctly installed in exhaust manifold
Pre catalyst heated Check for fuel control system related
oxygen sensor circuit DTCs and refer to the relevant DTC
short circuit to ground, index
short circuit to power, Refer to the electrical circuit diagrams
open circuit, high and check the pre catalyst heated
resistance oxygen sensor circuit for short circuit to
Pre catalyst heated ground, short circuit to power, open
oxygen sensor failure circuit, high resistance
Check and install a new pre catalyst
heated oxygen sensor as required

P0131- O2 Sensor Circuit Low Exhaust system leak Check for and rectify any exhaust leak
00 Voltage (Bank 1 Sensor 1) Fuel control system between cylinder head and catalytic
- No sub type information fault converter. Check pre catalyst heated
Pre catalyst heated oxygen sensor is correctly installed in
oxygen sensor to exhaust manifold
engine control module Check for fuel control system related
wiring shield high DTCs and refer to the relevant DTC
resistance index
Pre catalyst heated Refer to the electrical circuit diagrams
oxygen sensor failure and check pre catalyst heated oxygen
sensor to engine control module wiring
shield for high resistance
Check and install a new pre catalyst
heated oxygen sensor as required

P0132- O2 Sensor Circuit High Charge air system Check for and rectify any charge air
00 Voltage (Bank 1 Sensor 1) leakage system leaks. Check pre catalyst heated
- No sub type information Fuel control system oxygen sensor is correctly installed in
over fuelling exhaust manifold
Pre catalyst heated Check for fuel control system related
oxygen sensor failure DTCs and refer to the relevant DTC
index
Check and install a new pre catalyst
heated oxygen sensor as required
P0182- Fuel Temperature Sensor Fuel temperature Using the Jaguar Land Rover Approved
00 A Circuit Low - No sub sensor circuit short Diagnostic Equipment check datalogger
type information circuit to ground, high signals, Fuel Temperature "A" (0x0522),
resistance, open circuit Fuel Rail Temperature Sensor Voltage
Fuel temperature (0x033F)
sensor failure Refer to the electrical circuit diagrams
and check the fuel temperature sensor
circuit for short circuit to ground, high
resistance, open circuit. Repair harness
as required. Clear DTC and retest
Check and install a new fuel
temperature sensor as required

P0183- Fuel Temperature Sensor Fuel temperature Using the Jaguar Land Rover Approved
00 A Circuit High - No sub sensor circuit short Diagnostic Equipment check datalogger
type information circuit to power signals, Fuel Temperature "A" (0x0522),
Fuel temperature Fuel Rail Temperature Sensor Voltage
sensor failure (0x033F)
Refer to the electrical circuit diagrams
and check the fuel temperature sensor
circuit for short circuit to power. Repair
harness as required. Clear DTC and
retest
Check and install a new fuel
temperature sensor as required

P0192- Fuel Rail Pressure Sensor The engine control Using the Jaguar Land Rover Approved
16 A Circuit Low - Circuit module measured a Diagnostic Equipment check datalogger
voltage below threshold voltage below a signals, Fuel Rail Pressure Sensor
specified range but not (0x0324), Fuel Rail Pressure (0xF423)
necessarily a short Refer to the electrical circuit diagrams
circuit to ground and check the fuel rail pressure sensor
Fuel rail pressure circuit for short circuit to ground, high
sensor circuit short resistance, open circuit. Repair harness
circuit to ground, high as required. Clear DTC and retest
resistance, open circuit Check and install a new fuel rail
Fuel rail pressure pressure sensor as required
sensor failure

P0193- Fuel Rail Pressure Sensor The engine control Using the Jaguar Land Rover Approved
17 A Circuit High - Circuit module measured a Diagnostic Equipment check datalogger
voltage above threshold voltage above a signals, Fuel Rail Pressure Sensor
specified range but not (0x0324), Fuel Rail Pressure (0xF423)
necessarily a short Refer to the electrical circuit diagrams
circuit to power and check the fuel rail pressure sensor
Fuel rail pressure circuit for short circuit to power. Repair
sensor circuit short harness as required. Clear DTC and
circuit to power retest
Fuel rail pressure Check and install a new fuel rail
sensor failure pressure sensor as required

P0195- Engine Oil Temperature Oil contaminated or Check the oil level is correct and the oil
00 Sensor - No sub type level incorrect does not appear contaminated. Renew or
information Engine oil temperature top up oil as required
sensor power and Refer to the electrical circuit diagrams
ground supply circuits, and check the sensor power and ground
open circuit, short supplies for open circuit or short circuit
circuit to ground to ground
Engine oil temperature Refer to the electrical circuit diagrams
sensor signal circuit, and check engine oil temperature sensor
short circuit to ground, signal circuit, for short circuit to ground,
short circuit to power, short circuit to power, open circuit, high
open circuit, high resistance. Repair harness as required.
resistance Clear DTC and retest
Engine oil temperature Check and install a new engine oil
sensor failure temperature sensor as required

P0195- Engine Oil Temperature The engine control Check the oil level is correct and the oil
23 Sensor - Signal stuck low module measures a does not appear contaminated. Renew or
signal that remains top up oil as required
low when transitions Refer to the electrical circuit diagrams
are expected and check the sensor power and ground
Oil contaminated or supplies for open circuit or short circuit
level incorrect to ground
Engine oil temperature Refer to the electrical circuit diagrams
sensor power and and check engine oil temperature sensor
ground supply circuits, signal circuit, for short circuit to ground,
open circuit, short short circuit to power, open circuit, high
circuit to ground resistance. Repair harness as required.
Engine oil temperature Clear DTC and retest
sensor signal circuit, Check and install a new engine oil
short circuit to ground, temperature sensor as required
short circuit to power,
open circuit, high
resistance
Engine oil temperature
sensor failure

P0195- Engine Oil Temperature The engine control Check the oil level is correct and the oil
62 Sensor - Signal compare module detected does not appear contaminated. Renew or
failure failure when top up oil as required
comparing two or Start the engine from cold and allow to
more input parameters idle, check and record Sump Oil
for plausibility Temperature - Measured (0x03F3)
Oil contaminated or datalogger signal. Continue to warm up
level incorrect at idle, after approximately 10 minutes
Engine oil temperature check and record Sump Oil Temperature
sensor signal circuit, - Measured (0x03F3) signal. If value of
short circuit to ground, signal has not increased by 5°C check
short circuit to power, and install new oil level and temperature
open circuit, high sensor as required
resistance Refer to the electrical circuit diagrams
Engine oil temperature and check engine oil temperature sensor
sensor failure signal circuit, for short circuit to ground,
short circuit to power, open circuit, high
resistance. Repair harness as required.
Clear DTC and retest
Check and install a new engine oil
temperature sensor as required

P0197- Engine Oil Temperature Diagnostic fault check Refer to the electrical circuit diagrams
00 Sensor Circuit Low - No for low signal range and check engine oil temperature sensor
sub type information check signal circuit, for short circuit to ground
Engine oil temperature Check and install a new engine oil
sensor signal circuit, temperature sensor as required
short circuit to ground
Engine oil temperature
sensor failure

P0198- Engine Oil Temperature Diagnostic fault check Refer to the electrical circuit diagrams
00 Sensor Circuit High - No for high signal range and check engine oil temperature sensor
sub type information check signal circuit, for short circuit to power
Engine oil temperature Check and install a new engine oil
sensor signal circuit, temperature sensor as required
short circuit to power
Engine oil temperature
sensor failure

P0201- Cylinder 1 Injector Circuit Cylinder 1 fuel This DTC is set when the engine control
00 / Open - No sub type injector circuit, open module detects an open circuit on the
information circuit injector control circuit. Refer to the
Cylinder 1 fuel electrical circuit diagrams and check the
injector failure two control circuits between the engine
control module and the fuel injector for
high resistance, open circuits or
intermittent connections. Repair harness
as required. Clear DTC and retest
Check and install a new fuel injector as
required

P0202- Cylinder 2 Injector Circuit Cylinder 2 fuel This DTC is set when the engine control
00 / Open - No sub type injector circuit, open module detects an open circuit on the
information circuit injector control circuit. Refer to the
Cylinder 2 fuel electrical circuit diagrams and check the
injector failure two control circuits between the engine
control module and the fuel injector for
high resistance, open circuits or
intermittent connections. Repair harness
as required. Clear DTC and retest
Check and install a new fuel injector as
required

P0203- Cylinder 3 Injector Circuit Cylinder 3 fuel This DTC is set when the engine control
00 / Open - No sub type injector circuit, open module detects an open circuit on the
information circuit injector control circuit. Refer to the
Cylinder 3 fuel electrical circuit diagrams and check the
injector failure two control circuits between the engine
control module and the fuel injector for
high resistance, open circuits or
intermittent connections. Repair harness
as required. Clear DTC and retest
Check and install a new fuel injector as
required

P0204- Cylinder 4 Injector Circuit Cylinder 4 fuel This DTC is set when the engine control
00 / Open - No sub type injector circuit, open module detects an open circuit on the
information circuit injector control circuit. Refer to the
Cylinder 4 fuel electrical circuit diagrams and check the
injector failure two control circuits between the engine
control module and the fuel injector for
high resistance, open circuits or
intermittent connections. Repair harness
as required. Clear DTC and retest
Check and install a new fuel injector as
required

P0219- Engine Overspeed Injector leakage Check injectors for leakage


00 Condition - No sub type Oil pullover from the Check for fuel control system related
information sump due to over DTCs and refer to the relevant DTC
filling, causing the index
engine to run away Check air intake system for excessive
Camshaft or oil
crankshaft position Check the oil level is correct and the oil
sensor circuit short does not appear contaminated. Renew or
circuit to ground, short top up oil as required
circuit to power, open Refer to the electrical circuit diagrams
circuit and check camshaft and crankshaft
Camshaft or position sensor circuits for short circuit
crankshaft position to ground, short circuit to power, open
sensor failure circuit
Check for engine oil contamination to
sensors. Check and install new camshaft
and crankshaft position sensor as
required

P0237- Turbocharger/Supercharger Variable geometry NOTE:


00 Boost Sensor A Circuit turbine vane actuator
Low - No sub type sensor circuit, short Using the Jaguar Land Rover Approved
information circuit to power, short Diagnostic Equipment perform the (Turbo,
circuit to ground, open EGR and air path dynamic test) routine
circuit
Variable geometry Refer to the electrical circuit diagrams
turbine turbocharger and check the variable geometry turbine
stuck or damaged vane actuator sensor circuit, for short
Variable geometry circuit to power, short circuit to ground,
turbine vane actuator open circuit
stuck Check for stuck or damaged variable
geometry turbine turbocharger
Using the Jaguar Land Rover Approved
Diagnostic Equipment perform routine -
Inline diagnostic unit 2 diagnostic test -
Turbocharger
Check and install a new variable
geometry turbine vane actuator as
required

P0238- Turbocharger/Supercharger Variable geometry NOTE:


00 Boost Sensor A Circuit turbine vane actuator
High - No sub type sensor circuit, short Using the Jaguar Land Rover Approved
information circuit to power, short Diagnostic Equipment perform the (Turbo,
circuit to ground, open EGR and air path dynamic test) routine
circuit
Variable geometry Refer to the electrical circuit diagrams
turbine turbocharger and check the variable geometry turbine
stuck or damaged vane actuator circuit, for short circuit to
Variable geometry power, short circuit to ground, open
turbine vane actuator circuit
stuck Check for stuck or damaged variable
geometry turbine turbocharger
Using the Jaguar Land Rover Approved
Diagnostic Equipment perform routine -
Inline diagnostic unit 2 diagnostic test -
Turbocharger
Check and install a new variable
geometry turbine vane actuator as
required

P0251- Injection Pump Fuel The engine control Using the Jaguar Land Rover Approved
13 Metering Control A - module has Diagnostic Equipment check datalogger
Circuit open determined an open signals, Fuel Volume Control Valve
circuit via lack of bias Duty Cycle (0x03C2), Fuel Volume
voltage, low current Control Valve Current - Measured
flow, no change in the (0x03EA)
state of an input in Refer to the electrical circuit diagrams
response to an output and check the fuel volume control valve
Fuel volume control circuit for open circuit. Repair harness
valve circuit, open as required. Clear DTC and retest
circuit Check and install a new fuel volume
Fuel volume control control valve as required
valve failure

P0251- Injection Pump Fuel The engine control Refer to the electrical circuit diagrams
4B Metering Control A - Over module detected an and check the fuel volume control valve
temperature internal temperature circuit for short circuit to ground, short
above the expected circuit to power, high resistance. Repair
range harness as required. Clear DTC and
Fuel volume control retest
valve circuit short Check and install a new fuel volume
circuit to ground, short control valve as required
circuit to power, high
resistance
Fuel volume control
valve failure

P0253- Injection Pump Fuel Fuel volume control Using the Jaguar Land Rover Approved
00 Metering Control A Low - valve circuit short Diagnostic Equipment check datalogger
No sub type information circuit to ground, high signals, Fuel Volume Control Valve
resistance, open Duty Cycle (0x03C2), Fuel Volume
circuit, intermittent Control Valve Current - Measured
fault (0x03EA)
Fuel volume control Refer to the electrical circuit diagrams
valve failure and check the fuel volume control valve
circuit for short circuit to ground, high
resistance open circuit, intermittent
faults. Repair harness as required. Clear
DTC and retest
Check and install a new fuel volume
control valve as required

P0254- Injection Pump Fuel Fuel volume control Using the Jaguar Land Rover Approved
00 Metering Control A High - valve circuit short Diagnostic Equipment check datalogger
No sub type information circuit to power signals, Fuel Volume Control Valve
Fuel volume control Duty Cycle (0x03C2), Fuel Volume
valve failure Control Valve Current - Measured
(0x03EA)
Refer to the electrical circuit diagrams
and check the fuel volume control valve
circuit for short circuit to power. Repair
harness as required. Clear DTC and
retest
Check and install a new fuel volume
control valve as required

P0261- Cylinder 1 Injector Circuit Cylinder 1 fuel Refer to the electrical circuit diagrams
00 Low - No sub type injector circuit short and check cylinder 1 fuel injector circuit
information circuit to ground, high for short circuit to ground, high
resistance, open circuit resistance, open circuit. This circuit is a
Cylinder 1 fuel twisted pair, check both high and low
injector failure sides for short circuit to ground. Repair
harness as required. Clear DTC and
retest
Check and install a new cylinder 1 fuel
injector as required

P0261- Cylinder 1 Injector Circuit The engine control Refer to the electrical circuit diagrams
23 Low - Signal stuck low module measures a and check cylinder 1 fuel injector circuit
signal that remains for short to another cylinder fuel injector
low when transitions circuit. Repair harness as required. Clear
are expected DTC and retest
Cylinder 1 fuel
injector circuit short to
another cylinder fuel
injector

P0262- Cylinder 1 Injector Circuit Cylinder 1 fuel Refer to the electrical circuit diagrams
00 High - No sub type injector circuit short and check cylinder 1 fuel injector circuit
information circuit to power for short circuit to power. This circuit is
Cylinder 1 fuel a twisted pair, check both high and low
injector failure sides for short circuit to power. Repair
harness as required. Clear DTC and
retest
Check and install a new cylinder 1 fuel
injector as required

P0264- Cylinder 2 Injector Circuit Cylinder 2 injector Refer to the electrical circuit diagrams
00 Low - No sub type circuit short circuit to and check cylinder 2 fuel injector circuit
information ground, high for short circuit to ground, high
resistance, open circuit resistance, open circuit. This circuit is a
Cylinder 2 injector twisted pair, check both high and low
failure sides for short circuit to ground. Repair
harness as required. Clear DTC and
retest
Check and install a new cylinder 2 fuel
injector as required

P0264- Cylinder 2 Injector Circuit The engine control Refer to the electrical circuit diagrams
23 Low - Signal stuck low module measures a and check cylinder 2 fuel injector circuit
signal that remains for short to another cylinder fuel injector
low when transitions circuit. Repair harness as required. Clear
are expected DTC and retest
Cylinder 2 fuel
injector circuit short to
another cylinder fuel
injector

P0265- Cylinder 2 Injector Circuit Cylinder 2 fuel Refer to the electrical circuit diagrams
00 High - No sub type injector circuit short and check cylinder 2 fuel injector circuit
information circuit to power for short circuit to power. This circuit is
Cylinder 2 fuel a twisted pair, check both high and low
injector failure sides for short circuit to power. Repair
harness as required. Clear DTC and
retest
Check and install a new cylinder 2 fuel
injector as required

P0267- Cylinder 3 Injector Circuit Cylinder 3 fuel Refer to the electrical circuit diagrams
00 Low - No sub type injector circuit short and check cylinder 3 fuel injector circuit
information circuit to ground, high for short circuit to ground, high
resistance, open circuit resistance, open circuit. This circuit is a
Cylinder 3 fuel twisted pair, check both high and low
injector failure sides for short circuit to ground. Repair
harness as required. Clear DTC and
retest
Check and install a new cylinder 3 fuel
injector as required

P0267- Cylinder 3 Injector Circuit The engine control Refer to the electrical circuit diagrams
23 Low - Signal stuck low module measures a and check cylinder 3 fuel injector circuit
signal that remains for short to another cylinder fuel injector
low when transitions circuit. Repair harness as required. Clear
are expected DTC and retest
Cylinder 3 fuel
injector circuit short to
another cylinder fuel
injector

P0268- Cylinder 3 Injector Circuit Cylinder 3 fuel Refer to the electrical circuit diagrams
00 High - No sub type injector circuit short and check cylinder 3 fuel injector circuit
information circuit to power for short circuit to power. This circuit is
Cylinder 3 fuel a twisted pair, check both high and low
injector failure sides for short circuit to power. Repair
harness as required. Clear DTC and
retest
Check and install a new cylinder 3 fuel
injector as required

P0270- Cylinder 4 Injector Circuit Cylinder 4 fuel Refer to the electrical circuit diagrams
00 Low - No sub type injector circuit short and check cylinder 4 fuel injector circuit
information circuit to ground, high for short circuit to ground, high
resistance, open circuit resistance, open circuit. This circuit is a
Cylinder 4 fuel twisted pair, check both high and low
injector failure sides for short circuit to ground. Repair
harness as required. Clear DTC and
retest
Check and install a new cylinder 4 fuel
injector as required

P0270- Cylinder 4 Injector Circuit The engine control Refer to the electrical circuit diagrams
23 Low - Signal stuck low module measures a and check cylinder 4 fuel injector circuit
signal that remains for short to another cylinder fuel injector
low when transitions circuit. Repair harness as required. Clear
are expected DTC and retest
Cylinder 4 fuel
injector circuit short to
another cylinder fuel
injector

P0271- Cylinder 4 Injector Circuit Cylinder 4 fuel Refer to the electrical circuit diagrams
00 High - No sub type injector circuit short and check cylinder 4 fuel injector circuit
information circuit to power for short circuit to power. This circuit is
Cylinder 4 fuel a twisted pair, check both high and low
injector failure sides for short circuit to power. Repair
harness as required. Clear DTC and
retest
Check and install a new cylinder 4 fuel
injector as required

P0336- Crankshaft Position Sensor The engine control Refer to the electrical circuit diagrams
31 A Circuit module does not detect and check the crankshaft position sensor
Range/Performance - No a signal which ought circuit for short circuit to ground, short
signal to be present circuit to power, open circuit, high
Crankshaft position resistance
sensor circuit short Refer to the relevant section of the
circuit to ground, short workshop manual and check the
circuit to power, open crankshaft position sensor and target
circuit, high resistance wheel for correct installation, condition
Crankshaft position and alignment. Repair as required
sensor failure Check and install a new crankshaft
Crankshaft position position sensor
sensor target wheel
failure

P0336- Crankshaft Position Sensor The engine control Refer to the electrical circuit diagrams
64 A Circuit module detected and check the crankshaft position sensor
Range/Performance - plausibility failures circuit for short circuit to ground, short
Signal plausibility failure Crankshaft position circuit to power, open circuit, high
sensor circuit short resistance
circuit to ground, short Refer to the electrical circuit diagrams
circuit to power, open and check the crankshaft position sensor
circuit, high resistance shielding circuit for short circuit to
Crankshaft position power, open circuit, high resistance,
sensor circuit damage
shielding failure Refer to the relevant section of the
Crankshaft position workshop manual and check crankshaft
sensor foreign matter position sensor for foreign matter on
on sensor face, gap crankshaft position sensor face. Check
incorrect crankshaft position sensor air gap (check
Crankshaft position at 90° intervals, should be no greater
sensor failure than 4.5mm)
Crankshaft position Refer to the relevant section of the
sensor target wheel workshop manual and check the
fault crankshaft position sensor and target
wheel for correct installation, condition
and alignment. Repair as required
Check and install a new crankshaft
position sensor

P0341- Camshaft Position Sensor Camshaft position Refer to the electrical circuit diagrams
3A A Circuit sensor circuit short and check camshaft position sensor
Range/Performance (Bank circuit to ground, short circuit for short circuit to power, short
1 or single sensor) - circuit to power circuit to ground and intermittent faults
Incorrect has too many Camshaft position Refer to the relevant section of the
pulses sensor or reference workshop manual and check the
target positioning camshaft position sensor and target
incorrect wheel for correct installation, condition
Camshaft position and alignment. Repair as required
sensor failure Check and install a new camshaft
position sensor as required

P0341- Camshaft Position Sensor The engine control Refer to the electrical circuit diagrams
64 A Circuit module detected and check camshaft position sensor
Range/Performance (Bank plausibility failures circuit for short circuit to power, short
1 or single sensor) - Signal Camshaft position circuit to ground and intermittent faults
plausibility failure sensor circuit short Refer to the relevant section of the
circuit to ground, short workshop manual and check the
circuit to power camshaft position sensor and target
Camshaft position wheel for correct installation, condition
sensor or reference and alignment. Repair as required
target positioning Check and install a new camshaft
incorrect position sensor as required
Camshaft position
sensor failure

P0342- Camshaft Position Sensor The engine control Refer to the electrical circuit diagrams
31 A Circuit Low (Bank 1 or module does not detect and check camshaft position sensor
single sensor) - No signal a signal which ought circuit for open circuit, high resistance
to be present Refer to the relevant section of the
Camshaft position workshop manual and check the
sensor circuit open camshaft position sensor and target
circuit, high resistance wheel for correct installation, condition
Camshaft position and alignment. Repair as required
sensor or reference Check and install a new camshaft
target positioning position sensor as required
incorrect
Camshaft position
sensor failure

P0380- Glow Plug/Heater Circuit The engine control Refer to the electrical circuit diagrams
11 A - Circuit short to ground module has detected a and check the control circuit from the
ground measurement engine control module to the glow plug
for a period longer control module for short circuit to
than expected or has ground
detected a ground Check and install a new glow plug
measurement when control module
another value was
expected
Engine control module
to glow plug control
module circuit short
circuit to ground
Glow plug control
module failure

P0380- Glow Plug/Heater Circuit The engine control Refer to the electrical circuit diagrams
12 A - Circuit short to battery module has detected a and check the control circuit from the
vehicle power engine control module to the glow plug
measurement for a control module for short circuit to power
period longer than Check and install a new glow plug
expected or has control module
detected a vehicle
power measurement
when another value
was expected
Engine control module
to glow plug control
module circuit short
circuit to power
Glow plug control
module failure

P0380- Glow Plug/Heater Circuit The engine control Refer to the electrical circuit diagrams
13 A - Circuit open module has and check engine control module to
determined an open glow plug control module circuit for
circuit via lack of bias high resistance, open circuit
voltage, low current Check and install a new glow plug
flow, no change in the control module as required
state of an input in
response to an output
Engine control module
to glow plug control
module circuit high
resistance, open circuit
Glow plug control
module failure

P0380- Glow Plug/Heater Circuit The engine control Using the Jaguar Land Rover Approved
4B A - Over temperature module detected an Diagnostic Equipment check the engine
internal temperature control module for related DTCs and
above the expected refer to the relevant DTC index
range Refer to the electrical circuit diagrams
Engine control module and check engine control module to
to glow plug control glow plug control module circuit for
module circuit short short circuit to ground short circuit to
circuit to ground, short power
circuit to power Check and install a new glow plug
Glow plug control control module as required
module failure

P0401- Exhaust Gas Recirculation Intake air system Check intake air system for leakage
00 A Flow Insufficient leakage Refer to the electrical circuit diagrams
Detected - No sub type Exhaust gas and check exhaust gas recirculation
information recirculation electric electric actuator circuit for short circuit
actuator circuit short to ground, open circuit, high resistance.
circuit to ground, open Repair harness as required. Clear DTC
circuit, high resistance and retest
Exhaust gas Check and install a new exhaust gas
recirculation valve recirculation electric actuator as
stuck closed required
Exhaust gas Using the Jaguar Land Rover Approved
recirculation electric Diagnostic Equipment, perform routine -
actuator failure Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest

P0402- Exhaust Gas Recirculation Intake air system Check intake air system for leakage
00 A Flow Excessive leakage Refer to the electrical circuit diagrams
Detected - No sub type Exhaust gas and check exhaust gas recirculation
information recirculation electric electric actuator circuit for short circuit
actuator circuit short to power, open circuit, high resistance.
circuit to power, open Repair harness as required. Clear DTC
circuit, high resistance and retest
Exhaust gas Check and install a new exhaust gas
recirculation valve recirculation electric actuator as
stuck open required
Exhaust gas Using the Jaguar Land Rover Approved
recirculation electric Diagnostic Equipment, perform routine -
actuator failure Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest

P0403- Exhaust Gas Recirculation The engine control NOTE:


13 "A" Control Circuit / Open module has
- Circuit open determined an open Using the Jaguar Land Rover Approved
circuit via lack of bias Diagnostic Equipment perform the (Turbo,
voltage, low current EGR and air path dynamic test) routine
flow, no change in the
state of an input in Using the Jaguar Land Rover Approved
response to an output Diagnostic Equipment check datalogger
Exhaust gas signals, Exhaust Gas Recirculation
recirculation electric Valve - Commanded (0xF42C), Exhaust
actuator circuit, open Gas Recirculation Valve (0xF469)
circuit, high resistance Refer to the electrical circuit diagrams
Exhaust gas and check exhaust gas recirculation
recirculation electric electric actuator circuit for open circuit,
actuator failure high resistance. Repair harness as
required. Clear DTC and retest
Using the Jaguar Land Rover Approved
Diagnostic Equipment, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install a new exhaust gas
recirculation electric actuator as
required

P0403- Exhaust Gas Recirculation The engine control Using the Jaguar Land Rover Approved
16 "A" Control Circuit / Open module measured a Diagnostic Equipment check datalogger
- Circuit voltage below voltage below a signals, Exhaust Gas Recirculation
threshold specified range but not Valve - Commanded (0xF42C), Exhaust
necessarily a short Gas Recirculation Valve (0xF469)
circuit to ground Refer to the electrical circuit diagrams
Exhaust gas and check exhaust gas recirculation
recirculation electric electric actuator circuit for short circuit
actuator circuit short to ground, open circuit, high resistance.
circuit to ground, open Repair harness as required. Clear DTC
circuit, high resistance and retest
Exhaust gas Using the Jaguar Land Rover Approved
recirculation electric Diagnostic Equipment, perform routine -
actuator failure Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install a new exhaust gas
recirculation electric actuator as
required

P0403- Exhaust Gas Recirculation The engine control Using the Jaguar Land Rover Approved
19 "A" Control Circuit / Open module has measured Diagnostic Equipment check datalogger
- Circuit current above current flow above a signals, Exhaust Gas Recirculation
threshold specified range Valve - Commanded (0xF42C), Exhaust
Exhaust gas Gas Recirculation Valve (0xF469)
recirculation electric Refer to the electrical circuit diagrams
actuator circuit short and check exhaust gas recirculation
circuit to power, open electric actuator circuit for short circuit
circuit, high resistance to power, open circuit, high resistance.
Exhaust gas Repair harness as required. Clear DTC
recirculation electric and retest
actuator failure Using the Jaguar Land Rover Approved
Diagnostic Equipment, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install a new exhaust gas
recirculation electric actuator as
required

P0403- Exhaust Gas Recirculation Exhaust gas Using the Jaguar Land Rover Approved
1D "A" Control Circuit / Open recirculation electric Diagnostic Equipment check datalogger
- Circuit current out of actuator circuit short signals, Exhaust Gas Recirculation
range circuit to ground, short Valve - Commanded (0xF42C), Exhaust
circuit to power, open Gas Recirculation Valve (0xF469)
circuit, high resistance Refer to the electrical circuit diagrams
Exhaust gas and check exhaust gas recirculation
recirculation electric electric actuator circuit for short circuit
actuator failure to ground, short circuit to power, open
circuit, high resistance. Repair harness
as required. Clear DTC and retest
Using the Jaguar Land Rover Approved
Diagnostic Equipment, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install a new exhaust gas
recirculation electric actuator as
required

P0403- Exhaust Gas Recirculation The engine control Refer to the electrical circuit diagrams
4B "A" Control Circuit / Open module detected an and check exhaust gas recirculation
- Over temperature internal temperature electric actuator circuit for short circuit
above the expected to ground, short circuit to power, open
range circuit, high resistance. Repair harness
Exhaust gas as required. Clear DTC and retest
recirculation electric Using the Jaguar Land Rover Approved
actuator circuit short Diagnostic Equipment, perform routine -
circuit to ground, short Inline diagnostic unit 2 diagnostic test -
circuit to power, open Exhaust gas recirculation valve. Clear
circuit, high resistance the DTCs and retest
Exhaust gas Check and install a new exhaust gas
recirculation electric recirculation electric actuator as
actuator failure required

P0403- Exhaust Gas Recirculation Exhaust gas NOTES:


71 "A" Control Circuit / Open recirculation electric
- Actuator stuck actuator circuit short Using the Jaguar Land Rover Approved
circuit to ground, short Diagnostic Equipment perform the
circuit to power, open (Turbo, EGR and air path dynamic test)
circuit, high resistance routine
Exhaust gas
recirculation valve Using the Jaguar Land Rover Approved
stuck Diagnostic Equipment, perform the
Exhaust gas airpath set-up routine and retest the
recirculation electric vehicle
actuator failure
Using the Jaguar Land Rover Approved
Diagnostic Equipment check datalogger
signals, Exhaust Gas Recirculation
Valve - Commanded (0xF42C), Exhaust
Gas Recirculation Valve (0xF469)
Refer to the electrical circuit diagrams
and check exhaust gas recirculation
electric actuator circuit for short circuit
to ground, short circuit to power, open
circuit, high resistance. Repair harness
as required. Clear DTC and retest
Using the Jaguar Land Rover Approved
Diagnostic Equipment, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install a new exhaust gas
recirculation electric actuator as
required

P0404- Exhaust Gas Recirculation The engine control Refer to the electrical circuit diagrams
19 A Control Circuit module has measured and check exhaust gas recirculation
Range/Performance - current flow above a electric actuator circuit for short circuit
Circuit current above specified range to ground, short circuit to power. Repair
threshold Exhaust gas harness as required. Clear DTC and
recirculation electric retest
actuator circuit short Using the Jaguar Land Rover Approved
circuit to ground, short Diagnostic Equipment, perform routine -
circuit to power Inline diagnostic unit 2 diagnostic test -
Exhaust gas Exhaust gas recirculation valve. Clear
recirculation electric the DTCs and retest
actuator failure Check and install a new exhaust gas
recirculation electric actuator as
required

P0405- Exhaust Gas Recirculation Exhaust gas Using the Jaguar Land Rover Approved
00 Sensor A Circuit Low - No recirculation electric Diagnostic Equipment check datalogger
sub type information actuator circuit short signals, EGR Valve Position Bank 1
circuit to ground, open (0x052E)
circuit, high resistance Refer to the electrical circuit diagrams
Exhaust gas and check exhaust gas recirculation
recirculation electric electric actuator circuit for short circuit
actuator failure to ground, open circuit, high resistance.
Repair harness as required. Clear DTC
and retest
Using the Jaguar Land Rover Approved
Diagnostic Equipment, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Using the Jaguar Land Rover Approved
Diagnostic Equipment, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install a new exhaust gas
recirculation electric actuator as
required

P0405- Exhaust Gas Recirculation Exhaust gas NOTES:


77 Sensor A Circuit Low - recirculation electric
Commanded position not actuator stuck open Using the Jaguar Land Rover Approved
reachable Exhaust gas Diagnostic Equipment perform the
recirculation electric (Turbo, EGR and air path dynamic test)
actuator circuit short routine
circuit to ground, open
circuit, high resistance Using the Jaguar Land Rover Approved
Exhaust gas Diagnostic Equipment, perform the
recirculation electric airpath set-up routine and retest the
actuator failure vehicle

Using the Jaguar Land Rover Approved


Diagnostic Equipment check datalogger
signals, EGR Valve Position Bank 1
(0x052E)
Check exhaust gas recirculation electric
actuator for stuck open
Refer to the electrical circuit diagrams
and check exhaust gas recirculation
electric actuator circuit for short circuit
to ground, open circuit, high resistance.
Repair harness as required. Clear DTC
and retest
Using the Jaguar Land Rover Approved
Diagnostic Equipment, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install a new exhaust gas
recirculation electric actuator as
required

P0406- Exhaust Gas Recirculation Exhaust gas NOTE:


00 Sensor A Circuit High - No recirculation electric
sub type information actuator circuit short Using the Jaguar Land Rover Approved
circuit to power Diagnostic Equipment perform the (Turbo,
Exhaust gas EGR and air path dynamic test) routine
recirculation electric
actuator failure Using the Jaguar Land Rover Approved
Diagnostic Equipment check datalogger
signals, EGR Valve Position Bank 1
(0x052E)
Refer to the electrical circuit diagrams
and check exhaust gas recirculation
electric actuator circuit for short circuit
to power. Repair harness as required.
Clear DTC and retest
Using the Jaguar Land Rover Approved
Diagnostic Equipment, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Using the Jaguar Land Rover Approved
Diagnostic Equipment, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install a new exhaust gas
recirculation electric actuator as
required

P0406- Exhaust Gas Recirculation The engine control NOTE:


77 Sensor A Circuit High - module is unable to
Commanded position not command a motor, Using the Jaguar Land Rover Approved
reachable solenoid or relay, to Diagnostic Equipment perform the (Turbo,
move a piece of EGR and air path dynamic test) routine
equipment to the
commanded position Using the Jaguar Land Rover Approved
either due to a failure Diagnostic Equipment check datalogger
in the actuator or its signals, EGR Valve Position Bank 1
mechanical (0x052E)
environment Check for exhaust gas recirculation
Exhaust gas electric actuator stuck closed
recirculation electric Refer to the electrical circuit diagrams
actuator stuck closed and check exhaust gas recirculation
Exhaust gas electric actuator circuit for short circuit
recirculation electric to ground, short circuit to power. Repair
actuator circuit short harness as required. Clear DTC and
circuit to ground, short retest
circuit to power Using the Jaguar Land Rover Approved
Exhaust gas Diagnostic Equipment, perform routine -
recirculation electric Inline diagnostic unit 2 diagnostic test -
actuator failure Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install a new exhaust gas
recirculation electric actuator as
required

P0409- Exhaust Gas Recirculation The engine control Refer to the electrical circuit diagrams
16 Sensor A Circuit - Circuit module measured a and check exhaust gas recirculation
voltage below threshold voltage below a electric actuator circuit for short circuit
specified range but not to ground, open circuit, high resistance.
necessarily a short Repair harness as required. Clear DTC
circuit to ground and retest
Exhaust gas Using the Jaguar Land Rover Approved
recirculation electric Diagnostic Equipment, perform routine -
actuator circuit short Inline diagnostic unit 2 diagnostic test -
circuit to ground, open Exhaust gas recirculation valve. Clear
circuit, high resistance the DTCs and retest
Exhaust gas Check and install a new exhaust gas
recirculation electric recirculation electric actuator as
actuator failure required

P0409- Exhaust Gas Recirculation The engine control NOTE:


17 Sensor A Circuit - Circuit module measured a
voltage above threshold voltage above a Using the Jaguar Land Rover Approved
specified range but not Diagnostic Equipment perform the (Turbo,
necessarily a short EGR and air path dynamic test) routine
circuit to power
Exhaust gas Refer to the electrical circuit diagrams
recirculation electric and check exhaust gas recirculation
actuator circuit short electric actuator circuit for short circuit
circuit to ground, short to ground, short circuit to power. Repair
circuit to power harness as required. Clear DTC and
Exhaust gas retest
recirculation electric Using the Jaguar Land Rover Approved
actuator failure Diagnostic Equipment, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install a new exhaust gas
recirculation electric actuator as
required

P0480- Fan 1 Control Circuit - The engine control Using the Jaguar Land Rover Approved
11 Circuit short to ground module has detected a Diagnostic Equipment, check datalogger
ground measurement signal - Engine Cooling Fan Speed -
for a period longer Desired (0x03B9). Enable output state
than expected or has control, set the fan speed to 95% and run
detected a ground the fan for 30 seconds
measurement when Refer to the electrical circuit diagrams
another value was and check the cooling fan control
expected module circuit for short circuit to
Cooling fan control ground. Repair harness as required.
module circuit short Using the Jaguar Land Rover Approved
circuit to ground Diagnostic Equipment, clear the DTCs
Cooling fan control and retest
module failure If fault persists, refer to the relevant
section of the workshop manual and
refer to the cooling fan pinpoint test
procedures (see Pinpoint Test D) For
additional information, refer to: Engine
Cooling (303-03A Engine Cooling -
TD4 2.2L Diesel, Diagnosis and
Testing).
If the fault persists, check and install a
new cooling fan control module as
required

P0480- Fan 1 Control Circuit - The engine control Using the Jaguar Land Rover Approved
12 Circuit short to battery module has detected a Diagnostic Equipment, check datalogger
vehicle power signal - Engine Cooling Fan Speed -
measurement for a Desired (0x03B9). Enable output state
period longer than control, set the fan speed to 95% and run
expected or has the fan for 30 seconds
detected a vehicle Refer to the electrical circuit diagrams
power measurement and check the cooling fan control
when another value module circuit for short circuit to power.
was expected Repair harness as required. Using the
Cooling fan motor Jaguar Land Rover Approved
control module circuit Diagnostic Equipment, clear the DTCs
short circuit to power and retest
Cooling fan motor If fault persists, refer to the relevant
control module failure section of the workshop manual and
refer to the cooling fan pinpoint test
procedures (see Pinpoint Test D) For
additional information, refer to: Engine
Cooling (303-03A Engine Cooling -
TD4 2.2L Diesel, Diagnosis and
Testing).
If the fault persists, check and install a
new cooling fan control module as
required

P0480- Fan 1 Control Circuit - The engine control Using the Jaguar Land Rover Approved
13 Circuit open module has Diagnostic Equipment, check datalogger
determined an open signal - Engine Cooling Fan Speed -
circuit via lack of bias Desired (0x03B9). Enable output state
voltage, low current control, set the fan speed to 95% and run
flow, no change in the the fan for 30 seconds
state of an input in Refer to the electrical circuit diagrams
response to an output and check the cooling fan control
Cooling fan motor module circuit for high resistance, open
control module circuit circuit. Repair harness as required.
high resistance, open Using the Jaguar Land Rover Approved
circuit Diagnostic Equipment, clear the DTCs
Cooling fan motor and retest
control module failure If fault persists, refer to the relevant
section of the workshop manual and
refer to the cooling fan pinpoint test
procedures (see Pinpoint Test D) For
additional information, refer to: Engine
Cooling (303-03A Engine Cooling -
TD4 2.2L Diesel, Diagnosis and
Testing).
If the fault persists, check and install a
new cooling fan control module as
required
P0480- Fan 1 Control Circuit - The engine control Using the Jaguar Land Rover Approved
4B Over temperature module detected an Diagnostic Equipment, check datalogger
internal temperature signal - Engine Cooling Fan Speed -
above the expected Desired (0x03B9). Enable output state
range control, set the fan speed to 95% and run
Cooling fan motor the fan for 30 seconds
control module circuit Refer to the electrical circuit diagrams
short circuit to ground, and check the cooling fan control
short circuit to power, module circuit for short circuit to
high resistance ground, short circuit to power, high
Cooling fan motor resistance. Repair harness as required.
control module failure Using the Jaguar Land Rover Approved
Diagnostic Equipment, clear the DTCs
and retest
If fault persists, refer to the relevant
section of the workshop manual and
refer to the cooling fan pinpoint test
procedures (see Pinpoint Test D) For
additional information, refer to: Engine
Cooling (303-03A Engine Cooling -
TD4 2.2L Diesel, Diagnosis and
Testing).
If the fault persists, check and install a
new cooling fan control module as
required

P0486- Exhaust Gas Recirculation The engine control Refer to the electrical circuit diagrams
16 Sensor B Circuit - Circuit module measured a and check electric throttle position
voltage below threshold voltage below a sensor circuit for short circuit to ground,
specified range but not open circuit. Repair harness as required.
necessarily a short Clear DTC and retest
circuit to ground Check and install a new electric throttle
Electric throttle unit as required
position sensor circuit
short circuit to ground,
open circuit
Electric throttle unit
failure

P0486- Exhaust Gas Recirculation The engine control Refer to the electrical circuit diagrams
17 Sensor B Circuit - Circuit module measured a and check electric throttle position
voltage above threshold voltage above a sensor circuit for short circuit to power.
specified range but not Repair harness as required. Clear DTC
necessarily a short and retest
circuit to power Check and install a new electric throttle
Electric throttle unit as required
position sensor circuit
short circuit to power
Electric throttle unit
failure

P0487- Exhaust Gas Recirculation Electric throttle Refer to the electrical circuit diagrams
00 Throttle Control Circuit A / control circuit open and check electric throttle control circuit
Open - No sub type circuit, short circuit to for open circuit, short circuit to ground,
information ground, short circuit to short circuit to power. Repair harness as
power required. Clear DTC and retest
Electric throttle failure Check and install a new electric throttle
unit as required

P0487- Exhaust Gas Recirculation The engine control Refer to the electrical circuit diagrams
19 Throttle Control Circuit A / module has measured and check electric throttle control circuit
Open - Circuit current current flow above a for short circuit to power, short circuit to
above threshold specified range ground, high resistance, open circuit.
Electric throttle Repair harness as required. Clear DTC
control circuit short and retest
circuit to power, short Refer to the electrical circuit diagrams
circuit to ground, high and check electric throttle control power
resistance, open circuit and ground supplies for short circuit to
Electric throttle power each other. Repair harness as required.
and ground supplies Clear DTC and retest
shorted to each other Check and install a new electric throttle
Electric throttle failure unit as required

P0488- Exhaust Gas Recirculation Electric throttle unit Check electric throttle unit for damage
00 Throttle Control Circuit A stuck or obstructions that are preventing
Range/Performance - No Electric throttle unit movement of the valve. Repair as
sub type information damaged or obstructed required
Check and install a new electric throttle
unit as required

P0488- Exhaust Gas Recirculation The engine control Refer to the electrical circuit diagrams
16 Throttle Control Circuit A module measured a and check electric throttle control circuit
Range/Performance - voltage below a for open circuit, short circuit to ground,
Circuit voltage below specified range but not short circuit to power. Repair harness as
threshold necessarily a short required. Clear DTC and retest
circuit to ground Check and install a new electric throttle
Electric throttle unit as required
control circuit open
circuit, short circuit to
ground, short circuit to
power
Electric throttle failure

P0488- Exhaust Gas Recirculation The engine control Refer to the electrical circuit diagrams
19 Throttle Control Circuit A module has measured and check electric throttle control circuit
Range/Performance - current flow above a for short circuit to ground, high
Circuit current above specified range resistance. Repair harness as required.
threshold Electric throttle Clear DTC and retest
control circuit short Check and install a new electric throttle
circuit to ground, high unit as required
resistance
Electric throttle failure

P0488- Exhaust Gas Recirculation The engine control Refer to the electrical circuit diagrams
1D Throttle Control Circuit A module has detected a and check electric throttle control circuit
Range/Performance - current outside of the for high resistance, open circuit, short
Circuit current out of range expected range, but circuit to ground, short circuit to power
not identified as too and short circuit to another circuit.
high or too low Repair harness as required. Clear DTC
Electric throttle and retest
control circuit high Check and install a new electric throttle
resistance, open unit as required
circuit, short circuit to
ground, short circuit to
power, short circuit to
another circuit
Electric throttle failure

P0488- Exhaust Gas Recirculation The engine control Refer to the electrical circuit diagrams
4B Throttle Control Circuit A module detected an and check electric throttle control circuit
Range/Performance - Over internal temperature for short circuit to power, short circuit to
temperature above the expected ground, high resistance, open circuit.
range Repair harness as required. Clear DTC
Electric throttle and retest
control circuit short Refer to the electrical circuit diagrams
circuit to power, short and check electric throttle control power
circuit to ground, high and ground supplies for short circuit to
resistance, open circuit each other. Repair harness as required.
Electric throttle power Clear DTC and retest
and ground supplies Check and install a new electric throttle
shorted to each other unit as required
Electric throttle failure

P0489- Exhaust Gas Recirculation The engine control NOTE:


73 Control Circuit Low - module did not detect
Actuator stuck closed any motion upon Using the Jaguar Land Rover Approved
commanding the Diagnostic Equipment perform the (Turbo,
operation of a motor, EGR and air path dynamic test) routine
solenoid or relay to
open some piece of Check electric throttle unit valve for
equipment stuck closed
Electric throttle unit Check electric throttle unit for damage
valve stuck closed or obstructions that are preventing
Electric throttle unit movement of the valve. Repair as
damaged or obstructed required
Electric throttle Refer to the electrical circuit diagrams
control circuit, short and check connections are secure and
circuit to ground electric throttle control circuit for short
circuit to ground. Repair harness as
required. Clear DTC and retest

P0490- Exhaust Gas Recirculation The engine control Check electric throttle unit valve for
72 A Control Circuit High - module did not detect stuck open
Actuator stuck open any motion upon Check electric throttle unit for damage
commanding the or obstructions that are preventing
operation of a motor, movement of the valve. Repair as
solenoid or relay to required
close some piece of Refer to the electrical circuit diagrams
equipment and check connections are secure and
Electric throttle unit electric throttle control circuit for short
valve stuck open circuit to power. Repair harness as
Electric throttle unit required. Clear DTC and retest
damaged or obstructed
Electric throttle
control circuit, short
circuit to power

P049D- Exhaust Gas Recirculation Electric throttle NOTE:


00 A Control Position control circuit short
Exceeded Learning Limit - circuit to power, short Using the Jaguar Land Rover Approved
No sub type information circuit to ground, high Diagnostic Equipment perform the (Turbo,
resistance, open circuit EGR and air path dynamic test) routine
Electric throttle unit
damaged or obstructed Refer to the electrical circuit diagrams
Electric throttle unit and check electric throttle control circuit
failure for short circuit to power, short circuit to
ground, high resistance, open circuit.
Repair harness as required. Clear DTC
and retest
Check electric throttle unit for damage
or obstructions that are preventing
movement of the valve. Repair as
required
Using the Jaguar Land Rover Approved
Diagnostic Equipment, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install a new electric throttle
unit as required

P0504- Brake Switch A / B The signal transitions Check for related brake pressure DTCs
27 Correlation - Signal rate of more quickly than is within the anti-lock brake system
change above threshold reasonably allowed control module
Brake pedal switch Check brake pedal switch is fitted
plunger failure correctly
Brake pedal switch not Check and install a new brake switch as
fitted correctly required. Clear DTC, start the engine
Brake switch A failure press the brake pedal, using maximum
travel for greater than 1 minute taking
care not to press the accelerator pedal

P0504- Brake Switch A / B The engine control Refer to the electrical circuit diagrams
62 Correlation - Signal module detected and check both brake pedal switch
compare failure failure when circuits for short circuit to power, open
comparing two or circuit. Repair harness as required. Clear
more input parameters DTC and retest
for plausibility
Error check for brake
plausibility
Brake pedal switch
circuits short circuit to
power, open circuit

P050F- Brake Assist Vacuum Too The debounced and Refer to the electrical circuit diagrams
00 Low - No sub type not inverted brake and check connections are secure and
information vacuum sensor brake vacuum sensor circuit for short
indicates vacuum circuit to power, short circuit to ground,
insufficient for a open circuit
calibrated detection Check for correct function of the
time vacuum pump and vacuum system
Brake vacuum sensor Check and install a new brake vacuum
circuit short circuit to sensor as required
power, short circuit to
ground, open circuit
Brake vacuum sensor
failure
Vacuum pump or
vacuum system failure

P0512- Starter Request Circuit - The engine control Refer to the electrical circuit diagrams
24 Signal stuck high module measures a and check start request signal circuit
signal that remains between central junction box and engine
high when transitions control module for short circuit to power
are expected Using the Jaguar Land Rover Approved
Start request signal Diagnostic Equipment refer to the body
circuit between central control module and check for start
junction box and button related DTCs
engine control module, Check and install a new start button as
short circuit to power required
Start button stuck

P0512- Starter Request Circuit - The engine control Using the Jaguar Land Rover Approved
64 Signal plausibility failure module detected Diagnostic Equipment, check central
plausibility failures junction box for DTCs and refer to the
Mismatch between relevant DTC index
hardwired signal and Refer to the electrical circuit diagrams
crank signal over CAN and check crank request circuit for short
Crank request circuit circuit to power, short circuit to ground,
short circuit to power, open circuit, high resistance
short circuit to ground, Check and install a new start button as
open circuit, high required
resistance
Start button stuck

P0513- Incorrect Immobilizer Key Security key invalid Check for CAN network interference or
00 - No sub type information Immobilizer receives engine control module related DTCs
an unknown key status Using the Jaguar Land Rover Approved
Diagnostic Equipment carry out a
network integrity test
Using the Jaguar Land Rover Approved
Diagnostic Equipment, carry out the
immobilisation procedure

P0532- A/C Refrigerant Pressure The refrigerant Refer to the electrical circuit diagrams
00 Sensor A Circuit Low - No pressure sensor signal and check refrigerant pressure sensor
sub type information is monitored for signal circuit for short circuit to ground
operation in a defined Check and install a new refrigerant
range pressure sensor as required
Refrigerant pressure
sensor signal circuit
short circuit to ground
Refrigerant pressure
sensor failure

P0533- A/C Refrigerant Pressure The refrigerant Refer to the electrical circuit diagrams
00 Sensor A Circuit High - No pressure sensor signal and check refrigerant pressure sensor
sub type information is monitored for signal circuit for short circuit to power,
operation in a defined open circuit
range Check and install a new refrigerant
Refrigerant pressure pressure sensor as required
sensor signal circuit
short circuit to power,
open circuit
Refrigerant pressure
sensor failure

P0544- Exhaust Gas Temperature Pre catalyst exhaust Refer to the electrical circuit diagrams
00 Sensor Circuit - Bank 1 gas temperature sensor and check connections are secure, pre
Sensor 1 - No sub type circuit, short circuit to catalyst exhaust gas temperature sensor
information power, short circuit to circuit, for short circuit to power, short
ground, open circuit circuit to ground, open circuit
Pre catalyst exhaust Check and install a new pre catalyst
gas temperature sensor exhaust gas temperature sensor as
failure required

P0544- Exhaust Gas Temperature The engine control NOTE:


64 Sensor Circuit - Bank 1 module detected
Sensor 1 - Signal plausibility failures Using the Jaguar Land Rover Approved
plausibility failure Pre catalyst exhaust Diagnostic Equipment perform the (Turbo,
gas temperature sensor EGR and air path dynamic test) routine
circuit, short circuit to
power, short circuit to Refer to the electrical circuit diagrams
ground, open circuit and check, connections are secure, pre
Pre catalyst exhaust catalyst exhaust gas temperature sensor
gas temperature sensor circuit for short circuit to power, short
failure circuit to ground, open circuit
Check and install a new pre catalyst
exhaust gas temperature sensor as
required

P0545- Exhaust Gas Temperature Pre catalyst exhaust Refer to the electrical circuit diagrams
00 Sensor Circuit Low - Bank gas temperature sensor and check pre catalyst exhaust gas
1 Sensor 1 - No sub type circuit disconnected temperature sensor circuit for short
information Pre catalyst exhaust circuit to ground, high resistance, open
gas temperature sensor circuit, disconnected. Repair harness as
circuit short circuit to required. Clear DTC and retest
ground, high Check and install a new pre catalyst
resistance, open circuit exhaust gas temperature sensor as
Pre catalyst exhaust required
gas temperature sensor
failure

P0546- Exhaust Gas Temperature Pre catalyst exhaust Refer to the electrical circuit diagrams
00 Sensor Circuit High - Bank gas temperature sensor and check pre catalyst exhaust gas
1 Sensor 1 - No sub type circuit short circuit to temperature sensor for short circuit to
information power power. Repair harness as required. Clear
Pre catalyst exhaust DTC and retest
gas temperature sensor Check and install a new pre catalyst
failure exhaust gas temperature sensor as
required

P0564- Cruise Control Multi- The engine control Using the Jaguar Land Rover Approved
82 Function Input A Circuit - module detected that a Diagnostic Equipment carry out a
Alive / sequence counter signal was received network integrity test
incorrect / not updated without the Refer to the electrical circuit diagrams
corresponding rolling and check CAN circuits. Repair wiring
count value being harness as required
properly updated Refer to the electrical circuit diagrams
Communication error and check the cruise control multi-
between engine function switch circuit for short circuit
control module and to ground, short circuit to power, open
steering wheel switch circuit, high resistance
pack Check and install a new cruise control
Speed control multi- multi-function switch as required
function switch circuit
short circuit to ground,
short circuit to power,
open circuit, high
resistance
Cruise control multi-
function switch stuck

P0571- Brake Switch A Circuit - The engine control Using the Jaguar Land Rover Approved
62 Signal compare failure module detected Diagnostic Equipment carry out network
failure when integrity test
comparing two or Check for related DTCs and refer to the
more input parameters relevant DTC index
for plausibility Check and install new brake switch as
The brake switch required
signal received over
CAN is defective
Brake switch failure

P0571- Brake Switch A Circuit - Brake pedal pressed Ensure driver has not lightly pressed
68 Event information by driver at same time both brake pedal and accelerator pedal
as accelerator pedal for extended periods of time
pressed for long Refer to the electrical circuit diagrams
periods and check brake pedal switch A for
Brake pedal switch A short circuit to ground, short circuit to
short circuit to ground, power
short circuit to power Check and install new brake switch as
Brake switch A failure required

P0571- Brake Switch A Circuit - The engine control Using the Jaguar Land Rover Approved
82 Alive / sequence counter module detected that a Diagnostic Equipment carry out a
incorrect / not updated signal was received network integrity test
without the Refer to the electrical circuit diagrams
corresponding rolling and check CAN circuits. Repair wiring
count value being harness as required
properly updated Ensure driver has not lightly pressed
Communication error both brake pedal and accelerator pedal
between engine for extended periods of time
control module and Refer to the electrical circuit diagrams
anti-lock brake system and check brake pedal switch A for
control module short circuit to ground, short circuit to
Brake pedal pressed power
by driver at same time Check and install a new brake pedal
as accelerator pedal switch A as required
pressed for long
periods
Brake pedal switch A
short circuit to ground,
short circuit to power
Brake switch A failure
P0575- Cruise Control Input The engine control Check speed control buttons are not
81 Circuit - Invalid serial data module detected a jammed/contaminated/damaged. Check
received signal was received cruise control module for related DTCs
with the corresponding and refer to the relevant DTC index
validity bit equal to
"invalid" or post
processing of the
signal determines it is
invalid
The DTC sets if the
cancel, set minus, set
plus, resume, headway
increase and headway
decrease speed control
buttons have been
pressed for longer than
a calibrated period of
time. The system then
assumes a
stuck/damaged button
and will cancel and/or
disable cruise. The
DTC will be healed in
the next driving cycle
if the failure is
removed

P0578- Cruise Control Multi- Speed control multi- Refer to the electrical circuit diagrams
00 Function Input A Circuit function switch circuit and check the speed control multi-
Stuck - No sub type short circuit to ground, function switch circuit for short circuit
information short circuit to power, to ground, short circuit to power, open
open circuit, high circuit, high resistance
resistance Check and install a new cruise control
Cruise control multi- multi-function switch as required
function switch stuck

P0602- Powertrain Control Module Mismatch between car Using the Jaguar Land Rover Approved
00 Programming Error - No configuration file and Diagnostic Equipment check the correct
sub type information engine control module engine control module calibration has
calibration for been downloaded to the engine control
expected engine power module. Clear DTC and retest
output Using the Jaguar Land Rover Approved
Incorrect engine Diagnostic Equipment re-configure the
control module engine control module. Clear DTC and
calibration for vehicle retest
specification
Corrupt engine control
module software
download

P0605- Internal Control Module Corrupt engine control Using the Jaguar Land Rover Approved
00 Read Only Memory module software flash Diagnostic Equipment re-configure the
(ROM) Error - No sub type Engine control module engine control module
information power supply failure Refer to the electrical circuit diagrams
Engine control module and check the engine control module
ground supply failure power and ground supplies for open
Engine control module circuit. Repair harness as required. Clear
failure DTC and retest
Check and install new engine control
module as required

P0606- Control Module Processor Corrupt engine control Using the Jaguar Land Rover Approved
00 - No sub type information module software flash Diagnostic Equipment re-configure the
Engine control module engine control module
power supply failure Refer to the electrical circuit diagrams
Engine control module and check the engine control module
ground supply failure power and ground supplies for open
Engine control module circuit. Repair harness as required. Clear
failure DTC and retest
Check and install new engine control
module as required

P0606- Control Module Processor Corrupt engine control Using the Jaguar Land Rover Approved
44 - Data memory failure module software flash Diagnostic Equipment re-configure the
Engine control module engine control module
power supply failure Refer to the electrical circuit diagrams
Engine control module and check the engine control module
ground supply failure power and ground supplies for open
Engine control module circuit. Repair harness as required. Clear
failure DTC and retest
Check and install new engine control
module as required

P0606- Control Module Processor Corrupt engine control Using the Jaguar Land Rover Approved
49 - Internal electronic failure module software flash Diagnostic Equipment re-configure the
Engine control module engine control module
power supply failure Refer to the electrical circuit diagrams
Engine control module and check the engine control module
ground supply failure power and ground supplies for open
Engine control module circuit. Repair harness as required. Clear
failure DTC and retest
Check and install new engine control
module as required

P0607- Control Module Engine control module Check and install a new engine control
00 Performance - No sub type failure module as required
information
P060A- Internal Control Module Corrupt engine control Using the Jaguar Land Rover Approved
00 Monitoring Processor module software flash Diagnostic Equipment re-configure the
Performance - No sub type Engine control module engine control module. Clear DTC and
information power supply failure retest
Engine control module Refer to the electrical circuit diagrams
ground supply failure and check the engine control module
Engine control module ground, power circuit for short circuit to
failure ground, short circuit to power, open
circuit, high resistance
Check and install a new engine control
module as required

P060A- Internal Control Module The engine control Using the Jaguar Land Rover Approved
16 Monitoring Processor module measured a Diagnostic Equipment re-configure the
Performance - Circuit voltage below a engine control module. Clear DTC and
voltage below threshold specified range but not retest
necessarily a short Refer to the electrical circuit diagrams
circuit to ground and check the engine control module
Corrupt engine control ground, power circuit for short circuit to
module software ground, open circuit, high resistance
download Check and install a new engine control
Engine control module module as required
ground, power supply
circuit short circuit to
ground, open circuit,
high resistance
Engine control module
failure

P060A- Internal Control Module The engine control Using the Jaguar Land Rover Approved
17 Monitoring Processor module measured a Diagnostic Equipment re-configure the
Performance - Circuit voltage above a engine control module. Clear DTC and
voltage above threshold specified range but not retest
necessarily a short Refer to the electrical circuit diagrams
circuit to power and check the engine control module
Corrupt engine control ground, power circuit for short circuit to
module software power
download Check and install a new engine control
Engine control module module as required
ground, power supply
circuit short circuit to
power
Engine control module
failure

P060B- Internal Control Module Corrupt engine control Using the Jaguar Land Rover Approved
00 A/D Processing module software Diagnostic Equipment re-configure the
Performance - No sub type download engine control module. Clear DTC and
information Engine control module retest
ground, power supply Refer to the electrical circuit diagrams
circuit short circuit to and check the engine control module
ground, short circuit to ground, power circuit for short circuit to
power, open circuit, ground, short circuit to power, open
high resistance circuit, high resistance
Engine control module Check and install a new engine control
failure module as required

P060B- Internal Control Module The engine control Using the Jaguar Land Rover Approved
16 A/D Processing module measured a Diagnostic Equipment re-configure the
Performance - Circuit voltage below a engine control module. Clear DTC and
voltage below threshold specified range but not retest
necessarily a short Refer to the electrical circuit diagrams
circuit to ground and check the engine control module
Corrupt engine control ground, power circuit for short circuit to
module software ground, open circuit, high resistance
download Check and install a new engine control
Engine control module module as required
ground, power supply
circuit short circuit to
ground, open circuit,
high resistance
Engine control module
failure
P060B- Internal Control Module The engine control Using the Jaguar Land Rover Approved
17 A/D Processing module measured a Diagnostic Equipment re-configure the
Performance - Circuit voltage above a engine control module. Clear DTC and
voltage above threshold specified range but not retest
necessarily a short Refer to the electrical circuit diagrams
circuit to power and check the engine control module
Corrupt engine control ground, power circuit for short circuit to
module software power
download Check and install a new engine control
Engine control module module as required
ground, power supply
circuit short circuit to
power
Engine control module
failure

P060B- Internal Control Module The engine control Using the Jaguar Land Rover Approved
63 A/D Processing module detected a Diagnostic Equipment re-configure the
Performance - Circuit / function is active for engine control module. Clear DTC and
component protection greater than a retest
time-out specified time period Refer to the electrical circuit diagrams
Corrupt engine control and check the engine control module
module software ground, power circuit for short circuit to
download ground, short circuit to power, open
Engine control module circuit, high resistance
ground, power supply Check and install a new engine control
circuit short circuit to module as required
ground, short circuit to
power, open circuit,
high resistance
Engine control module
failure

P060C- Internal Control Module Engine control module Using the Jaguar Land Rover Approved
00 Main Processor has reset due to Diagnostic Equipment clear the DTC
Performance - No sub type hardware or software and road test vehicle including at least 5
information fault ignition cycles. Re-check DTC and
Engine control module repeat above procedure. If DTC resets
failure check and install a new engine control
module as required

P060D- Internal Control Module Corrupt engine control Using the Jaguar Land Rover Approved
00 Accelerator Pedal Position module software Diagnostic Equipment re-configure the
Performance - No sub type download engine control module. Clear DTC and
information Accelerator pedal retest
position sensor circuit, Refer to the electrical circuit diagrams
short circuit to ground, and check the accelerator pedal position
short circuit to power, sensor circuit for short circuit to ground,
open circuit, high short circuit to power, open circuit, high
resistance resistance
Accelerator pedal Check and install a new accelerator
position sensor failure pedal position as required
Engine control module Check and install a new engine control
failure module as required
P0610- Control Module Vehicle Corrupt engine control Using the Jaguar Land Rover Approved
00 Options Error - No sub module software Diagnostic Equipment re-configure the
type information download engine control module. Clear DTC and
Incorrect car retest
configuration file Using the Jaguar Land Rover Approved
Engine control module Diagnostic Equipment re-configure the
ground, power supply car configuration file as required
circuit short circuit to Refer to the electrical circuit diagrams
ground, short circuit to and check the engine control module
power, open circuit, ground, power circuit for short circuit to
high resistance ground, short circuit to power, open
circuit, high resistance

P0615- Starter Relay Circuit - No Starter motor relay Refer to the electrical circuit diagrams
00 sub type information circuit short circuit to and check the starter motor relay circuit
power, short circuit to for short circuit to power, short circuit to
ground, open circuit, ground, open circuit, high resistance
high resistance Check and install a new starter motor
Starter motor relay relay as required
failure

P061A- Internal Control Module Corrupt engine control Using the Jaguar Land Rover Approved
00 Torque Performance - No module software Diagnostic Equipment check for related
sub type information download DTCs and repair these first. Clear DTC
Mass air flow sensor and retest
failure Using the Jaguar Land Rover Approved
Electric throttle unit Diagnostic Equipment re-configure the
failure engine control module. Clear DTC and
retest
Check and install a new manifold air
flow sensor as required
Check and install a new electric throttle
unit as required

P061B- Internal Control Module Corrupt engine control Using the Jaguar Land Rover Approved
00 Torque Calculation module software Diagnostic Equipment check for related
Performance - No sub type download DTCs and repair these first. Clear DTC
information Mass air flow sensor and retest
failure Using the Jaguar Land Rover Approved
Electric throttle unit Diagnostic Equipment re-configure the
failure engine control module. Clear DTC and
retest
Check and install a new manifold air
flow sensor as required
Check and install a new electric throttle
unit as required

P061C- Internal Control Module Corrupt engine control Using the Jaguar Land Rover Approved
00 Engine RPM Performance module software Diagnostic Equipment re-configure the
- No sub type information download engine control module. Clear DTC and
Engine control module retest
ground and power Refer to the electrical circuit diagrams
supply circuit short and check the engine control module
circuit to ground, short ground and power supply circuits for
circuit to power, open short circuit to ground, short circuit to
circuit, high resistance power, open circuit, high resistance
Engine control module Check and install a new engine control
failure module as required

P061C- Internal Control Module The engine control Using the Jaguar Land Rover Approved
62 Engine RPM Performance module detected Diagnostic Equipment check/amend the
- Signal compare failure failure when car configuration file
comparing two or
more input parameters
for plausibility
Car configuration
signal not received
Car configuration file
incorrect

P0620- Generator Control Circuit - Charging system Check the vehicle charging system
00 No sub type information failure performance to ensure the voltage
Generator circuit short regulation is correct
circuit to ground, short Refer to the electrical circuit diagrams
circuit to power, open and check generator circuit for short
circuit, high resistance circuit to ground, short circuit to power,
Generator failure open circuit, high resistance
Check and install a new generator as
required

P0627- Fuel Pump A Control Wiring harness fault Refer to the electrical circuit diagrams
00 Circuit / Open - No sub between engine and check the fuel pump relay control
type information control module and circuit between the engine control
battery junction box module and the battery junction box for
Fuel pump relay an open circuit. Repair harness as
failure required. Clear DTC and retest
Check and install a new fuel pump relay
as required
Using the Jaguar Land Rover Approved
Diagnostic Equipment, perform routine -
Inline diagnostic unit 2 non-intrusive
test - Low pressure fuel pump

P0627- Fuel Pump A Control The engine control Refer to the electrical circuit diagrams
13 Circuit / Open - Circuit module has and check fuel pump control circuit for
open determined an open open circuit. Clear DTC and retest
circuit via lack of bias Using the Jaguar Land Rover Approved
voltage, low current Diagnostic Equipment, perform routine -
flow, no change in the Inline diagnostic unit 2 non-intrusive
state of an input in test - Low pressure fuel pump
response to an output
Fuel pump control
circuit open circuit

P0627- Fuel Pump A Control The engine control Check power supply to the fuel pump
93 Circuit / Open - No module detected that relay for open circuit
operation the component is not Refer to the electrical circuit diagrams
operating and check the fuel pump relay control
Power supply to the circuit between the engine control
fuel pump relay open module and the battery junction box for
circuit an open circuit. Repair harness as
Wiring harness fault required. Clear DTC and retest
between engine Check and install a new fuel pump relay
control module and as required
battery junction box Using the Jaguar Land Rover Approved
Fuel pump relay Diagnostic Equipment, perform routine -
failure Inline diagnostic unit 2 non-intrusive
test - Low pressure fuel pump

P0628- Fuel Pump A Control The engine control Refer to the electrical circuit diagrams
11 Circuit Low - Circuit short module has detected a and check fuel pump control circuit for
to ground ground measurement short circuit to ground. Clear DTC and
for a period longer retest
than expected or has Using the Jaguar Land Rover Approved
detected a ground Diagnostic Equipment, perform routine -
measurement when Inline diagnostic unit 2 non-intrusive
another value was test - Low pressure fuel pump
expected
Fuel pump control
circuit short circuit to
ground

P0629- Fuel Pump A Control Engine control module Refer to the electrical circuit diagrams
00 Circuit High - No sub type to battery junction box and check engine control module to
information fuel pump control battery junction box fuel pump control
circuit short circuit to circuit for short circuit to power
power Check resistance of in tank fuel pump
In tank fuel pump Check and install a new fuel pump relay
failure as required
Fuel pump relay Using the Jaguar Land Rover Approved
failure Diagnostic Equipment, perform routine -
Inline diagnostic unit 2 non-intrusive
test - Low pressure fuel pump

P0629- Fuel Pump A Control The engine control Refer to the electrical circuit diagrams
12 Circuit High - Circuit short module has detected a and check fuel pump control circuit for
to battery vehicle power short circuit to power. Clear DTC and
measurement for a retest
period longer than Using the Jaguar Land Rover Approved
expected or has Diagnostic Equipment, perform routine -
detected a vehicle Inline diagnostic unit 2 non-intrusive
power measurement test - Low pressure fuel pump
when another value
was expected
Fuel pump control
circuit short circuit to
power

P062B- Internal Control Module Injector failure(s) Check for related injector DTCs and
00 Fuel Injector Control Corrupt engine control repair these first. Clear DTCs and retest
Performance - No sub type module software flash Using the Jaguar Land Rover Approved
information Engine control module Diagnostic Equipment re-configure the
power supply failure engine control module
Engine control module Refer to the electrical circuit diagrams
ground supply failure and check the engine control module
Engine control module power supply for open circuit. Repair
failure harness as required. Clear DTC and
retest
Refer to the electrical circuit diagrams
and check the engine control module
ground supply for open circuit. Repair
harness as required. Clear DTC and
retest
Check and install new engine control
module as required

P062B- Internal Control Module Injector failure(s) Check for related injector DTCs and
41 Fuel Injector Control Corrupt engine control repair these first. Clear DTCs and retest
Performance - General module software flash Using the Jaguar Land Rover Approved
checksum failure Engine control module Diagnostic Equipment re-configure the
power supply failure engine control module
Engine control module Refer to the electrical circuit diagrams
ground supply failure and check the engine control module
Engine control module power supply for open circuit. Repair
failure harness as required. Clear DTC and
retest
Refer to the electrical circuit diagrams
and check the engine control module
ground supply for open circuit. Repair
harness as required. Clear DTC and
retest
Check and install new engine control
module as required

P062B- Internal Control Module Injector failure(s) Check for related injector DTCs and
48 Fuel Injector Control Corrupt engine control repair these first. Clear DTCs and retest
Performance - Supervision module software flash Using the Jaguar Land Rover Approved
software failure Engine control module Diagnostic Equipment re-configure the
power supply failure engine control module
Engine control module Refer to the electrical circuit diagrams
ground supply failure and check the engine control module
Engine control module power supply for open circuit. Repair
failure harness as required. Clear DTC and
retest
Refer to the electrical circuit diagrams
and check the engine control module
ground supply for open circuit. Repair
harness as required. Clear DTC and
retest
Check and install new engine control
module as required

P062B- Internal Control Module Injector failure(s) Check for related injector DTCs and
49 Fuel Injector Control Corrupt engine control repair these first. Clear DTCs and retest
Performance - Internal module software flash Using the Jaguar Land Rover Approved
electronic failure Engine control module Diagnostic Equipment re-configure the
power supply failure engine control module
Engine control module Refer to the electrical circuit diagrams
ground supply failure and check the engine control module
Engine control module power supply for open circuit. Repair
failure harness as required. Clear DTC and
retest
Refer to the electrical circuit diagrams
and check the engine control module
ground supply for open circuit. Repair
harness as required. Clear DTC and
retest
Check and install new engine control
module as required

P062B- Internal Control Module The engine control Check for related injector DTCs and
62 Fuel Injector Control module detected repair these first. Clear DTCs and retest
Performance - Signal failure when Using the Jaguar Land Rover Approved
compare failure comparing two or Diagnostic Equipment re-configure the
more input parameters engine control module
for plausibility Refer to the electrical circuit diagrams
Injector failure(s) and check the engine control module
Corrupt engine control power supply for open circuit. Repair
module software flash harness as required. Clear DTC and
Engine control module retest
power supply failure Refer to the electrical circuit diagrams
Engine control module and check the engine control module
ground supply failure ground supply for open circuit. Repair
Engine control module harness as required. Clear DTC and
failure retest
Check and install new engine control
module as required

P062B- Internal Control Module The engine control Check for related injector DTCs and
64 Fuel Injector Control module detected repair these first. Clear DTCs and retest
Performance - Signal plausibility failures Using the Jaguar Land Rover Approved
plausibility failure Injector failure(s) Diagnostic Equipment re-configure the
Corrupt engine control engine control module
module software flash Refer to the electrical circuit diagrams
Engine control module and check the engine control module
power supply failure power supply for open circuit. Repair
Engine control module harness as required. Clear DTC and
ground supply failure retest
Engine control module Refer to the electrical circuit diagrams
failure and check the engine control module
ground supply for open circuit. Repair
harness as required. Clear DTC and
retest
Check and install new engine control
module as required

P062B- Internal Control Module Injector failure(s) Check for related injector DTCs and
91 Fuel Injector Control Corrupt engine control repair these first. Clear DTCs and retest
Performance - Parametric module software flash Using the Jaguar Land Rover Approved
Engine control module Diagnostic Equipment re-configure the
power supply failure engine control module
Engine control module Refer to the electrical circuit diagrams
ground supply failure and check the engine control module
Engine control module power supply for open circuit. Repair
failure harness as required. Clear DTC and
retest
Refer to the electrical circuit diagrams
and check the engine control module
ground supply for open circuit. Repair
harness as required. Clear DTC and
retest
Check and install new engine control
module as required

P062B- Internal Control Module The engine control Check for related injector DTCs and
92 Fuel Injector Control module has detected repair these first. Clear DTCs and retest
Performance - Performance that the component Using the Jaguar Land Rover Approved
or incorrect operation performance is outside Diagnostic Equipment re-configure the
its expected range or engine control module
operating in an Refer to the electrical circuit diagrams
incorrect way and check the engine control module
Injector failure(s) power supply for open circuit. Repair
Corrupt engine control harness as required. Clear DTC and
module software flash retest
Engine control module Refer to the electrical circuit diagrams
power supply failure and check the engine control module
Engine control module ground supply for open circuit. Repair
ground supply failure harness as required. Clear DTC and
Engine control module retest
failure Check and install new engine control
module as required

P062B- Internal Control Module The engine control Check for related injector DTCs and
94 Fuel Injector Control module detected that repair these first. Clear DTCs and retest
Performance - Unexpected the component is Using the Jaguar Land Rover Approved
operation operating in a way or Diagnostic Equipment re-configure the
at a time that it has not engine control module
been commanded to Refer to the electrical circuit diagrams
operate and check the engine control module
Injector failure(s) power supply for open circuit. Repair
Corrupt engine control harness as required. Clear DTC and
module software flash retest
Engine control module Refer to the electrical circuit diagrams
power supply failure and check the engine control module
Engine control module ground supply for open circuit. Repair
ground supply failure harness as required. Clear DTC and
Engine control module retest
failure Check and install new engine control
module as required

P062B- Internal Control Module Injector failure(s) Check for related injector DTCs and
9A Fuel Injector Control Corrupt engine control repair these first. Clear DTCs and retest
Performance - Component module software flash Using the Jaguar Land Rover Approved
or system operating Engine control module Diagnostic Equipment re-configure the
conditions power supply failure engine control module
Engine control module Refer to the electrical circuit diagrams
ground supply failure and check the engine control module
Engine control module power supply for open circuit. Repair
failure harness as required. Clear DTC and
retest
Refer to the electrical circuit diagrams
and check the engine control module
ground supply for open circuit. Repair
harness as required. Clear DTC and
retest
Check and install new engine control
module as required
P062C- Internal Control Module Signal error for Using the Jaguar Land Rover Approved
00 Vehicle Speed vehicle speed over Diagnostic Equipment, check anti-lock
Performance - No sub type CAN brake system control module for DTCs
information CAN circuit failure and refer to the relevant DTC index
Using the Jaguar Land Rover Approved
Diagnostic Equipment, complete a CAN
network integrity test

P062D- Fuel Injector Driver Circuit Engine control module Using the Jaguar Land Rover Approved
00 Performance Bank 1 - No power supplies, short Diagnostic Equipment check for related
sub type information circuit to power, short injector DTCs
circuit to ground, open Refer to the electrical circuit diagrams
circuit and check connections are secure and
Injector circuits, short engine control module power supplies
circuit to power, short for short circuit to power, short circuit to
circuit to ground, open ground, open circuit
circuit Refer to the electrical circuit diagrams
and check connections are secure and
injector circuits for short circuit to
power, short circuit to ground, open
circuit. Clear DTC and retest

P062D- Fuel Injector Driver Circuit The engine control Using the Jaguar Land Rover Approved
11 Performance Bank 1 - module has detected a Diagnostic Equipment check for related
Circuit short to ground ground measurement injector DTCs
for a period longer Refer to the electrical circuit diagrams
than expected or has and check connections are secure and
detected a ground engine control module power supplies
measurement when for short circuit to power, short circuit to
another value was ground, open circuit
expected Refer to the electrical circuit diagrams
Engine control module and check connections are secure and
power supplies, short injector circuits for short circuit to
circuit to power, short power, short circuit to ground, open
circuit to ground, open circuit. Clear DTC and retest
circuit
Injector circuits, short
circuit to power, short
circuit to ground, open
circuit

P062D- Fuel Injector Driver Circuit The engine control Using the Jaguar Land Rover Approved
16 Performance Bank 1 - module measured a Diagnostic Equipment check for related
Circuit voltage below voltage below a injector DTCs
threshold specified range but not Refer to the electrical circuit diagrams
necessarily a short and check connections are secure and
circuit to ground engine control module power supplies
Engine control module for short circuit to power, short circuit to
power supplies, short ground, open circuit
circuit to power, short Refer to the electrical circuit diagrams
circuit to ground, open and check connections are secure and
circuit injector circuits for short circuit to
Injector circuits, short power, short circuit to ground, open
circuit to power, short circuit. Clear DTC and retest
circuit to ground, open
circuit
P062D- Fuel Injector Driver Circuit The engine control Using the Jaguar Land Rover Approved
17 Performance Bank 1 - module measured a Diagnostic Equipment check for related
Circuit voltage above voltage above a injector DTCs
threshold specified range but not Refer to the electrical circuit diagrams
necessarily a short and check connections are secure and
circuit to power engine control module power supplies
Engine control module for short circuit to power, short circuit to
power supplies, short ground, open circuit
circuit to power, short Refer to the electrical circuit diagrams
circuit to ground, open and check connections are secure and
circuit injector circuits for short circuit to
Injector circuits, short power, short circuit to ground, open
circuit to power, short circuit. Clear DTC and retest
circuit to ground, open
circuit

P062E- Fuel Injector Driver Circuit Engine control module Using the Jaguar Land Rover Approved
00 Performance Bank 2 - No power supplies, short Diagnostic Equipment check for related
sub type information circuit to power, short injector DTCs
circuit to ground, open Refer to the electrical circuit diagrams
circuit and check connections are secure and
Injector circuits, short engine control module power supplies
circuit to power, short for short circuit to power, short circuit to
circuit to ground, open ground, open circuit
circuit Refer to the electrical circuit diagrams
and check connections are secure and
injector circuits for short circuit to
power, short circuit to ground, open
circuit. Clear DTC and retest

P062E- Fuel Injector Driver Circuit The engine control Using the Jaguar Land Rover Approved
11 Performance Bank 2 - module has detected a Diagnostic Equipment check for related
Circuit short to ground ground measurement injector DTCs
for a period longer Refer to the electrical circuit diagrams
than expected or has and check connections are secure and
detected a ground engine control module power supplies
measurement when for short circuit to power, short circuit to
another value was ground, open circuit
expected Refer to the electrical circuit diagrams
Engine control module and check connections are secure and
power supplies, short injector circuits for short circuit to
circuit to power, short power, short circuit to ground, open
circuit to ground, open circuit. Clear DTC and retest
circuit
Injector circuits, short
circuit to power, short
circuit to ground, open
circuit

P062E- Fuel Injector Driver Circuit The engine control Using the Jaguar Land Rover Approved
17 Performance Bank 2 - module measured a Diagnostic Equipment check for related
Circuit voltage above voltage above a injector DTCs
threshold specified range but not Refer to the electrical circuit diagrams
necessarily a short and check connections are secure and
circuit to power engine control module power supplies
Engine control module for short circuit to power, short circuit to
power supplies, short ground, open circuit
circuit to power, short Refer to the electrical circuit diagrams
circuit to ground, open and check connections are secure and
circuit injector circuits for short circuit to
Injector circuits, short power, short circuit to ground, open
circuit to power, short circuit. Clear DTC and retest
circuit to ground, open
circuit

P0633- Immobilizer Key Not EEPROM read failure Check and install a new engine control
00 Programmed - ECM/PCM during immobilizer module as required
- No sub type information validation
Engine control module
failure

P0641- Sensor Reference Voltage Engine control module Refer to the electrical circuit diagrams
1C A Circuit/Open - Circuit 5 volt power supplies, and check connections are secure and all
voltage out of range short circuit to 12 volt engine control module 5 volt power
power, short circuit to supplies for short circuit to power 12
ground, open circuit volts, short circuit to ground, open
circuit. Clear DTC and retest

P064D- Internal Control Module Charge air system Check charge air system for leakage
00 O2 Sensor Processor leakage Using the Jaguar Land Rover Approved
Performance - Bank 1 - No Pre catalyst heated Diagnostic Equipment check for related
sub type information oxygen sensor circuit pre catalyst heated oxygen sensor DTCs
short circuit to ground, and repair these first. Clear DTC and
short circuit to power, retest
open circuit, high Refer to the electrical circuit diagrams
resistance and check pre catalyst heated oxygen
Pre catalyst heated sensor for short circuit to ground,
oxygen sensor failure power, open circuit, high resistance
Engine control module Check and install a new heated oxygen
failure sensor as required
Check and install a new engine control
module as required

P064D- Internal Control Module The engine control Check for unmetered air entering the
16 O2 Sensor Processor module measured a intake system
Performance - Bank 1 - voltage below a Using the Jaguar Land Rover Approved
Circuit voltage below specified range but not Diagnostic Equipment check for related
threshold necessarily a short pre catalyst heated oxygen sensor DTCs
circuit to ground and repair these first. Clear DTC and
Unmetered air retest
entering the intake Refer to the electrical circuit diagrams
system and check pre catalyst heated oxygen
Pre catalyst heated sensor for short circuit to ground,
oxygen sensor circuit power, open circuit, high resistance
short circuit to ground, Check and install a new heated oxygen
short circuit to power, sensor as required
open circuit, high
resistance
Pre catalyst heated
oxygen sensor failure

P0651- Sensor Reference Voltage Engine control module Refer to the electrical circuit diagrams
1C B Circuit / Open - Circuit 5 volt power supplies, and check connections are secure and all
voltage out of range short circuit to 12 volt engine control module 5 volt power
power, short circuit to supplies for short circuit to power 12
ground, open circuit volts, short circuit to ground, open
circuit. Clear DTC and retest

P065A- Generator System Charging system Check the vehicle charging system
00 Performance - No sub type failure performance to ensure the voltage
information Generator circuit short regulation is correct
circuit to ground, short Refer to the electrical circuit diagrams
circuit to power, open and check generator circuit for short
circuit, high resistance circuit to ground, short circuit to power,
Generator failure open circuit, high resistance
Check and install a new generator as
required

P065B- Generator Control Circuit The engine control Refer to the electrical circuit diagrams
11 Range/Performance - module has detected a and check generator circuit for short
Circuit short to ground ground measurement circuit to ground
for a period longer Check and install a new generator as
than expected or has required
detected a ground
measurement when
another value was
expected
Generator circuit short
circuit to ground
Generator failure

P065B- Generator Control Circuit The engine control Check the vehicle charging system
16 Range/Performance - module measured a performance to ensure the voltage
Circuit voltage below voltage below a regulation is correct
threshold specified range but not Refer to the electrical circuit diagrams
necessarily a short and check generator circuit for short
circuit to ground circuit to ground
Generator circuit short Check and install a new generator as
circuit to ground required
Generator failure

P065B- Generator Control Circuit The engine control Check the vehicle charging system
17 Range/Performance - module measured a performance to ensure the voltage
Circuit voltage above voltage above a regulation is correct
threshold specified range but not Refer to the electrical circuit diagrams
necessarily a short and check generator circuit for short
circuit to power circuit to power
Generator circuit short Check and install a new generator as
circuit to power required
Generator failure

P0683- Glow Plug Control Module NOTE: Refer to the electrical circuit diagrams
23 to PCM Communication and check glow plug module to engine
Circuit - Signal stuck low Poor or non start in cold control module diagnostic feedback
conditions circuit for short circuit to ground
Refer to the electrical circuit diagrams
The engine control and check glow plug module to engine
module measures a control module control circuit, for short
signal that remains circuit to ground
low when transitions Check glow plugs for correct resistance
are expected Check and install a new glow plug
Diagnostic fault check control module
for signal not plausible
Glow plug module to
engine control module
diagnostic feedback
circuit short circuit to
ground
Glow plug module to
engine control module
control circuit short
circuit to ground
Glow plug control
module failure

P0683- Glow Plug Control Module NOTE: Refer to the electrical circuit diagrams
24 to PCM Communication and check glow plug module to engine
Circuit - Signal stuck high Poor or non start in cold control module diagnostic feedback
conditions circuit for short circuit to power, open
circuit
The engine control Refer to the electrical circuit diagrams
module measures a and check glow plug module to engine
signal that remains control module control circuit for short
high when transitions circuit to power, open circuit
are expected Check glow plugs for correct resistance
Diagnostic fault check Check and install a new glow plug
for signal not plausible control module
Glow plug module to
engine control module
diagnostic feedback
circuit short circuit to
power, open circuit
Glow plug module to
engine control module
control circuit short
circuit to power, open
circuit
Glow plug control
module failure

P0697- Sensor Reference Voltage Engine control module Refer to the electrical circuit diagrams
1C C Circuit / Open - Circuit 5 volt power supplies, and check connections are secure and all
voltage out of range short circuit to 12 volt engine control module 5 volt power
power, short circuit to supplies for short circuit to power 12
ground, open circuit volts, short circuit to ground, open
circuit. Clear DTC and retest

P06AF- Torque Management Engine control module Using the Jaguar Land Rover Approved
00 System - Forced Engine has requested an Diagnostic Equipment check for related
Shutdown - No sub type engine shutdown engine control module DTCs and repair
information these first. Clear the DTC and retest. If
this DTC remains alone check and
install a new engine control module as
required

P0700- Transmission Control MIL request by Using the Jaguar Land Rover Approved
00 System (MIL Request) - automatic gearbox Diagnostic Equipment, check
No sub type information transmission control module for DTCs
and refer to the relevant DTC index
Refer to the electrical circuit diagrams
and check connections are secure and
wiring integrity

P0703- Brake Switch B Circuit - The engine control Using the Jaguar Land Rover Approved
81 Invalid serial data received module detected a Diagnostic Equipment, check anti-lock
signal was received brake system control module for DTCs
with the corresponding and refer to the relevant DTC index
validity bit equal to Using the Jaguar Land Rover Approved
"invalid" or post Diagnostic Equipment, complete a CAN
processing of the network integrity test. Refer to the
signal determines it is electrical circuit diagrams and check
invalid anti-lock brake system control module
The engine control power and ground circuits for open
module has not circuit. Check CAN harness between
received the expected engine control module and anti-lock
brake signal brake system control module, repair as
information, over the required
CAN network, from
the anti-lock brake
system control module
CAN harness link
between engine
control module and
anti-lock brake system
control module
network failure

P0703- Brake Switch B Circuit - The engine control Using the Jaguar Land Rover Approved
86 Signal invalid module has Diagnostic Equipment, check central
determined failures junction box for DTCs and refer to the
where some circuit relevant DTC index
quantity, reported via Refer to the electrical circuit diagrams
serial data, is not and check CAN circuits. Repair wiring
plausible given the harness as required
operating conditions Using the Jaguar Land Rover Approved
CAN signal invalid Diagnostic Equipment, complete a CAN
from the central network integrity test. Refer to the
junction box electrical circuit diagrams and check
CAN harness link central junction box control module
between engine power and ground circuits for open
control module and circuit. Check CAN harness between
central junction box engine control module and central
network failure junction box, repair as necessary

P0805- Clutch Position Sensor "A" The engine control Refer to the electrical circuit diagrams
82 Circuit - Alive / sequence module detected that a and check connections are secure and
counter incorrect / not signal was received wiring integrity
updated without the Refer to the electrical circuit diagrams
corresponding rolling and check CAN circuits. Repair wiring
count value being harness as required
properly updated
Update bit error for
clutch pedal analog
position
Clutch switch circuit
open circuit, high
resistance
Harness fault - CAN
circuit

P0805- Clutch Position Sensor "A" Assembly fault for Refer to the electrical circuit diagrams
95 Circuit - Incorrect clutch pedal analog and check connections are secure and
assembly position wiring integrity
Clutch switch circuit Check clutch switch is installed
open circuit between correctly
clutch switch and Refer to the electrical circuit diagrams
central junction box and check CAN circuits. Repair wiring
Harness fault - CAN harness as required
circuit Check and install a new clutch switch as
Clutch switch failure required

P0807- Clutch Position Sensor "A" Minimum error for Refer to the electrical circuit diagrams
00 Circuit Low - No sub type clutch pedal analog and check connections are secure and
information position wiring integrity
Clutch switch circuit Refer to the electrical circuit diagrams
open circuit, short and check CAN circuits. Repair wiring
circuit to ground harness as required
between clutch switch
and central junction
box
Harness fault - CAN
circuit

P0808- Clutch Position Sensor "A" Maximum error for Refer to the electrical circuit diagrams
00 Circuit High - No sub type clutch pedal analog and check connections are secure and
information position wiring integrity
Clutch switch circuit Refer to the electrical circuit diagrams
to central junction and check CAN circuits. Repair wiring
box, short circuit to harness as required
power, short circuit to
ground
Harness fault - CAN
circuit

P0830- Clutch Pedal Switch A The engine control Refer to the electrical circuit diagrams
23 Circuit - Signal stuck low module measures a and check connections are secure and
signal that remains wiring integrity
low when transitions Refer to the electrical circuit diagrams
are expected and check Clutch TOT Switch circuit,
Clutch switch active for short circuit to ground
error 25 percent
Clutch TOT Switch
circuit, short circuit to
ground

P0830- Clutch Pedal Switch A The engine control Refer to the electrical circuit diagrams
24 Circuit - Signal stuck high module measures a and check connections are secure and
signal that remains wiring integrity
high when transitions Refer to the electrical circuit diagrams
are expected and check Clutch TOT Switch circuit,
Clutch switch inactive for short circuit to power
error 25 percent
Clutch TOT Switch
circuit, short circuit to
power

P0833- Clutch Pedal Switch B The engine control Refer to the electrical circuit diagrams
23 Circuit - Signal stuck low module measures a and check connections are secure and
signal that remains wiring integrity
low when transitions Refer to the electrical circuit diagrams
are expected and check Clutch TOT Switch circuit,
Clutch switch active for short circuit to ground
error 75 percent
Clutch TOT Switch
circuit, short circuit to
ground

P0833- Clutch Pedal Switch B The engine control Refer to the electrical circuit diagrams
24 Circuit - Signal stuck high module measures a and check connections are secure and
signal that remains wiring integrity
high when transitions Refer to the electrical circuit diagrams
are expected and check Clutch TOT Switch circuit,
Clutch switch inactive for short circuit to power
error 75 percent
Clutch TOT Switch
circuit, short circuit to
power

P083F- Clutch Pedal Switch A / B Synchronization error Refer to the electrical circuit diagrams
00 Correlation - No sub type for clutch signals and check connections are secure and
information Clutch switch failure wiring integrity
Check and install a new clutch switch as
required

P0850- Park / Neutral Switch Input The engine control Using the Jaguar Land Rover Approved
62 Circuit - Signal compare module detected Diagnostic Equipment, check
failure failure when transmission control module for DTCs
comparing two or and refer to the relevant DTC index
more input parameters Using the Jaguar Land Rover Approved
for plausibility Diagnostic Equipment, complete a CAN
Mismatch between network integrity test. Refer to the
park neutral sensor electrical circuit diagrams and check
and park neutral signal transmission control module power and
received over CAN ground circuits for open circuit. Check
CAN harness link CAN harness between engine control
between engine module and transmission control
control module and module, repair as necessary
transmission control Refer to the electrical circuit diagrams
module network and check park neutral switch circuit for
failure short circuit to ground, short circuit to
Park neutral switch power, open circuit, high resistance.
circuit short circuit to Clear DTC and retest
ground, short circuit to
power, open circuit,
high resistance
P0850- Park / Neutral Switch Input Mismatch between Using the Jaguar Land Rover Approved
87 Circuit - Missing message park neutral sensor Diagnostic Equipment, check
and park neutral signal transmission control module for DTCs
received over CAN and refer to the relevant DTC index
CAN harness link Using the Jaguar Land Rover Approved
between engine Diagnostic Equipment, complete a CAN
control module and network integrity test. Refer to the
transmission control electrical circuit diagrams and check
module network transmission control module power and
failure ground circuits for open circuit. Check
Park neutral switch CAN harness between engine control
circuit short circuit to module and transmission control
ground, short circuit to module, repair as necessary
power, open circuit, Refer to the electrical circuit diagrams
high resistance and check park neutral switch circuit for
short circuit to ground, short circuit to
power, open circuit, high resistance.
Clear DTC and retest

P0915- Gear Shift Position Circuit The value of the signal Using the Jaguar Land Rover Approved
29 Range/Performance - measured by the Diagnostic Equipment, check
Signal invalid engine control module transmission control module for DTCs
is not plausible given and refer to the relevant DTC index
the operating Refer to the electrical circuit diagrams
conditions and check connections are secure and
Transmission neutral wiring integrity
sensor signals
plausibility error

P0916- Gear Shift Position Circuit The engine control Refer to the electrical circuit diagrams
33 Low - Signal low time > module detected the and check transmission neutral sensor
maximum low pulse is too wide circuit, for short circuit to ground
with respect to time
Transmission neutral
sensor circuit short
circuit to ground

P0917- Gear Shift Position Circuit The engine control Refer to the electrical circuit diagrams
35 High - Signal high time > module detects that the and check transmission neutral sensor
maximum signal high time is circuit, for short circuit to power
greater than the
maximum value
Transmission neutral
sensor circuit short
circuit to power

P0A09- DC/DC Converter Status The engine control Using the Jaguar Land Rover Approved
16 Circuit Low - Circuit module measured a Diagnostic Equipment re-configure the
voltage below threshold voltage below a engine control module
specified range but not Refer to the electrical circuit diagrams
necessarily a short and check the engine control module
circuit to ground power supply for open circuit. Repair
Corrupt engine control harness as required. Clear DTC and
module software flash retest
Engine control module Refer to the electrical circuit diagrams
power supply failure and check the engine control module
Engine control module ground supply for open circuit. Repair
ground supply failure harness as required. Clear DTC and
Engine control module retest
failure Check and install new engine control
module as required

P0A10- DC/DC Converter Status The engine control Using the Jaguar Land Rover Approved
17 Circuit High - Circuit module measured a Diagnostic Equipment re-configure the
voltage above threshold voltage above a engine control module
specified range but not Refer to the electrical circuit diagrams
necessarily a short and check the engine control module
circuit to power power supply for open circuit. Repair
Corrupt engine control harness as required. Clear DTC and
module software flash retest
Engine control module Refer to the electrical circuit diagrams
power supply failure and check the engine control module
Engine control module ground supply for open circuit. Repair
ground supply failure harness as required. Clear DTC and
Engine control module retest
failure Check and install new engine control
module as required

P0A14- Engine Mount Control A The engine control Refer to the electrical circuit diagrams
13 Circuit / Open - Circuit module has and check engine mount control circuit
open determined an open for open circuit. Clear DTC, start engine
circuit via lack of bias and raise engine speed above 2000rpm
voltage, low current for 1 second
flow, no change in the Check and install a new engine mount
state of an input in vacuum solenoid as required
response to an output
Engine mount control
circuit open circuit
Engine mount vacuum
solenoid failure

P0A15- Engine Mount Control A The engine control Refer to the electrical circuit diagrams
11 Circuit Low - Circuit short module has detected a and check engine mount control circuit
to ground ground measurement for short circuit to ground. Clear DTC,
for a period longer start engine and raise engine speed
than expected or has above 2000rpm for 1 second
detected a ground Check and install a new engine mount
measurement when vacuum solenoid as required
another value was
expected
Engine mount control
circuit short circuit to
ground
Engine mount vacuum
solenoid failure

P0A16- Engine Mount Control A The engine control Refer to the electrical circuit diagrams
12 Circuit High - Circuit short module has detected a and check engine mount control circuit
to battery vehicle power for short circuit to power. Clear DTC,
measurement for a start engine and raise engine speed
period longer than above 2000rpm for 1 second
expected or has Check and install a new engine mount
detected a vehicle vacuum solenoid as required
power measurement
when another value
was expected
Engine mount control
circuit short circuit to
power
Engine mount vacuum
solenoid failure

P0A16- Engine Mount Control A The engine control Refer to the electrical circuit diagrams
4B Circuit High - Over module detected an and check engine mount control circuit
temperature internal temperature for short circuit to power. Clear DTC
above the expected and retest
range Check and install a new engine mount
Engine mount control vacuum solenoid as required
circuit short circuit to
power
Engine mount vacuum
solenoid failure

P0A1A- Generator Control Module Generator circuit short Refer to the electrical circuit diagrams
00 - No sub type information circuit to ground, high and check generator wiring for short
resistance, open circuit circuit to ground, high resistance, open
Charging system fault circuit. Repair harness as required. Clear
Generator failure DTC and retest
Check the vehicle charging system
performance to ensure the voltage
regulation is correct
Check and install a new generator as
required

P0A1A- Generator Control Module Generator to engine Refer to the electrical circuit diagrams
87 - Missing message control module LIN and check generator LIN circuit to
circuit short circuit to engine control module for good/clean
ground, short circuit to contact at connectors/pins. Check
power, open circuit, generator to engine control module LIN
high resistance circuit for short circuit to ground, short
Generator failure circuit to power, open circuit, high
Engine control module resistance. Using the Jaguar Land Rover
failure Approved Diagnostic Equipment check
for engine control module/hardware
related DTCs and refer to relevant DTC
index. Clear DTCs and retest
Check and install a new generator as
required
Check and install a new engine control
module as required

P0A3B- Generator Over Generator Refer to the electrical circuit diagrams


00 Temperature - No sub type wiring/connectors heat and check the generator wiring and
information damaged connectors for heat damage
Generator circuit short Refer to the electrical circuit diagrams
circuit to ground, high and check generator wiring for short
resistance circuit to ground, high resistance. Repair
Generator failure harness as required. Clear DTC and
retest
Check and install a new generator as
required

P115A- Low Fuel Level - Forced Low level fuel Check the fuel level, add fuel if
00 Limited Power - No sub condition required. Clear DTC and retest
type information Critical fuel level If there is sufficient fuel, refer to the
switch signal circuit electrical circuit diagrams and check the
short circuit to ground, critical fuel level switch circuits for
short circuit to power, short circuit to power, short circuit to
open circuit ground, open circuit. Repair harness as
Critical fuel level required. Clear DTC and retest
switch failure Check and install a new critical fuel
Fuel level sensor level switch as required
signal circuit short If there is sufficient fuel, refer to the
circuit to ground, short electrical circuit diagrams and check the
circuit to power, open fuel level sensor circuits for short circuit
circuit to power, short circuit to ground, open
Fuel level sensor circuit. Repair harness as required. Clear
failure DTC and retest
Check and install a new fuel level sensor
as required

P115B- Low Fuel Level - Forced Low level fuel Check the fuel level, add fuel if
68 Engine Shutdown - Event condition required. Clear DTC and retest
information Critical fuel level If there is sufficient fuel, refer to the
switch signal circuit electrical circuit diagrams and check the
short circuit to ground, critical fuel level switch circuits for
short circuit to power, short circuit to power, short circuit to
open circuit ground, open circuit. Repair harness as
Critical fuel level required. Clear DTC and retest
switch failure Check and install a new critical fuel
Fuel level sensor level switch as required
signal circuit short If there is sufficient fuel, refer to the
circuit to ground, short electrical circuit diagrams and check the
circuit to power, open fuel level sensor circuits for short circuit
circuit to power, short circuit to ground, open
Fuel level sensor circuit. Repair harness as required. Clear
failure DTC and retest
Check and install a new fuel level sensor
as required

P120F- Fuel Pressure Regulator Fuel rail pressure Refer to the electrical circuit diagrams
00 Excessive Variation - No sensor circuit short and check connections are secure and
sub type information circuit to power, short wiring integrity
circuit to ground, open Check and install a new fuel rail
circuit pressure sensor as required
Fuel rail pressure
sensor 5 volt signal
circuit, high resistance
Fuel rail pressure
sensor failure

P1259- Immobilizer to PCM The engine control Using the Jaguar Land Rover Approved
81 Signal Error - Invalid serial module detected a Diagnostic Equipment, carry out the
data received signal was received immobilisation procedure
with the corresponding
validity bit equal to
"invalid" or post
processing of the
signal determines it is
invalid
Incorrect target ID is
received from the
central junction box

P1259- Immobilizer to PCM The engine control Using the Jaguar Land Rover Approved
83 Signal Error - Value of module detected that a Diagnostic Equipment carry out a
signal protection message was network integrity test
calculation incorrect processed with an Refer to the electrical circuit diagrams
incorrect protection and check CAN circuits. Repair wiring
(checksum) harness as required
calculation Using the Jaguar Land Rover Approved
Harness fault - CAN Diagnostic Equipment, carry out the
circuit immobilisation procedure
Target ID is not
received from the
central junction box

P1259- Immobilizer to PCM The engine control Check and install a new engine control
84 Signal Error - Signal below module has module
allowable range determined failures
where some circuit
quantity, reported via
serial data, is below a
specified range
Engine control module
EEPROM is unable to
write the target ID
Engine control module
failure

P1259- Immobilizer to PCM The engine control Check and install a new engine control
85 Signal Error - Signal above module has module
allowable range determined failures
where some circuit
quantity, reported via
serial data, is above a
specified range
Engine control module
EEPROM is unable to
read the target ID
Engine control module
failure

P1575- Pedal Position Out Of Self Brake pedal switch Refer to the electrical circuit diagrams
00 Test Range - No sub type circuit short circuit to and check brake pedal switch circuit for
information power short circuit to power
Brake pedal switch Refer to the electrical circuit diagrams
circuit open circuit and check pedal switch circuit for open
Brake pedal switch circuit
failure Check and install a new brake pedal
switch as required. Clear the DTCs,
drive the vehicle at greater than 11mph
(17kph) with a throttle pedal greater
than 10% for greater than 3 seconds.
Press the brake pedal, using maximum
travel for greater than 3 seconds, with
the vehicle stationary, press the brake
pedal using maximum travel for greater
than 1 second

P1627- Module Supply Voltage The engine control This DTC is set when the engine control
16 Out Of Range - Circuit module measured a module supply voltage is below the
voltage below threshold voltage below a allowed minimum. Refer to the
specified range but not workshop manual and the battery care
necessarily a short manual, inspect the vehicle battery and
circuit to ground ensure it is fully charged and serviceable
Engine control module before performing further tests
power or ground Check the vehicle charging system
supply failure performance to ensure the voltage
Junction box failure regulation is correct
Engine management Refer to the electrical circuit diagrams
system control relay and check engine control module power
failure and ground circuits
Power distribution
failure
Vehicle battery failure
Charging system
failure

P1627- Module Supply Voltage The engine control This DTC is set when the engine control
17 Out Of Range - Circuit module measured a module supply voltage is above the
voltage above threshold voltage above a allowed maximum. Refer to the
specified range but not workshop manual and the battery care
necessarily a short manual, inspect the vehicle battery and
circuit to power ensure it is fully charged and serviceable
Engine control module before performing further tests
power or ground Check the vehicle charging system
supply failure performance to ensure the voltage
Junction box failure regulation is correct
Engine management Refer to the electrical circuit diagrams
system control relay and check engine control module power
failure and ground circuits
Power distribution
failure
Vehicle battery failure
Charging system
failure

P1631- Main Relay (Power Hold) - NOTE: Check the vehicle battery has not been
00 No sub type information disconnected before the engine
The early opening error management system relay has powered
detection is used to detect down
whether the main relay has Check the operation of the engine
been opened without any management system high current relay
request Refer to the electrical circuit diagrams
and check the engine management
Vehicle battery system high current relay supply and
disconnected before control circuits for open circuits, high
engine management resistance, short circuit to ground, short
system relay has circuit to power, short to other circuits
powered down Check and install a new engine control
Engine control module module high current relay as required
high current relay
failure
Engine control module
high current relay
control circuit failure
Junction box failure

P1631- Main Relay (Power Hold) - NOTE: Check the operation of the engine
73 Actuator stuck closed management system high current relay
This DTC is set when the Refer to the electrical circuit diagrams
engine management system and check the engine management
high current relay contacts system high current relay supply and
are detected stuck closed by control circuits for open circuits, high
the engine control module resistance, short circuit to ground, short
circuit to power, short to other circuits
The engine control Check and install a new engine
module did not detect management system high current relay
any motion upon as required
commanding the
operation of a motor,
solenoid or relay to
open some piece of
equipment
Engine management
system high current
relay failure
Engine control module
high current relay
control circuit failure

P164C- Internal Control Module Information contained Using the Jaguar Land Rover Approved
00 Start-Stop Performance - in the clutch pedal Diagnostic Equipment carry out a
No sub type information CAN signal to engine network integrity test
control module is Refer to the electrical circuit diagrams
unreliable and check CAN circuits. Repair wiring
Harness fault - CAN harness as required
circuit

P164C- Internal Control Module The engine control Using the Jaguar Land Rover Approved
93 Start-Stop Performance - module detected that Diagnostic Equipment carry out a
No operation the component is not network integrity test
operating Refer to the electrical circuit diagrams
Information contained and check CAN circuits. Repair wiring
in the clutch pedal harness as required
CAN signal to engine
control module is
unreliable
Harness fault - CAN
circuit

P1703- Brake Switch Out Of Self Brake switch circuit Refer to the electrical circuit diagrams
00 Test Range - No sub type short circuit to power, and check the brake switch circuit for
information short circuit to ground, short circuit to power, short circuit to
open circuit ground, open circuit
Brake switch failure Check and install a new brake switch as
required

P1712- Transmission Torque Plausibility fault Using the Jaguar Land Rover Approved
00 Reduction Request Signal - during increasing Diagnostic Equipment, check
No sub type information torque intervention by transmission control module for related
gearbox DTCs and refer to the relevant DTC
index
Using the Jaguar Land Rover Approved
Diagnostic Equipment, complete a CAN
network integrity test

P1712- Transmission Torque Transmission torque Using the Jaguar Land Rover Approved
57 Reduction Request Signal - gain error Diagnostic Equipment, check
Invalid / incomplete transmission control module for related
software component DTCs and refer to the relevant DTC
index
Using the Jaguar Land Rover Approved
Diagnostic Equipment, complete a CAN
network integrity test

P1712- Transmission Torque The engine control Using the Jaguar Land Rover Approved
84 Reduction Request Signal - module has Diagnostic Equipment, check
Signal below allowable determined failures transmission control module for related
range where some circuit DTCs and refer to the relevant DTC
quantity, reported via index
serial data, is below a Using the Jaguar Land Rover Approved
specified range Diagnostic Equipment, complete a CAN
Transmission torque network integrity test
ratio error
CAN signal TrqRatio
received by the engine
control module

P1712- Transmission Torque The engine control Using the Jaguar Land Rover Approved
85 Reduction Request Signal - module has Diagnostic Equipment, check
Signal above allowable determined failures transmission control module for related
range where some circuit DTCs and refer to the relevant DTC
quantity, reported via index
serial data, is above a Using the Jaguar Land Rover Approved
specified range Diagnostic Equipment, complete a CAN
Motor slip regulation network integrity test
torque intervention
signal update bit error
CAN signal error

P193C- Steering Wheel Angle The engine control Using the Jaguar Land Rover Approved
87 Signal - Missing message module has not Diagnostic Equipment, check steering
received the expected angle sensor for DTCs and refer to the
CAN signal from the relevant DTC index
steering angle sensor Using the Jaguar Land Rover Approved
within the specified Diagnostic Equipment, complete a CAN
time interval network integrity test. Refer to the
CAN harness link electrical circuit diagrams and check
between engine steering angle sensor power and ground
control module and circuits for open circuit. Check CAN
steering angle sensor harness between engine control module
network malfunction and steering angle sensor, repair as
necessary

P2031- Exhaust Gas Temperature Pre-catalyst Check the pre-catalyst temperature


00 Sensor Circuit Bank 1 temperature sensor sensor for contamination
Sensor 2 - No sub type contaminated Refer to the electrical circuit diagrams
information Pre-catalyst and check the pre-catalyst temperature
temperature sensor sensor circuits for short circuit to power,
circuit short circuit to short circuit to ground, open circuit,
power, short circuit to high resistance
ground, open circuit, Check and install a new pre-catalyst
high resistance temperature sensor as required
Pre-catalyst
temperature sensor
failure

P2032- Exhaust Gas Temperature Pre-catalyst Check the pre-catalyst temperature


00 Sensor Circuit Low Bank 1 temperature sensor sensor for contamination
Sensor 2 - No sub type contaminated Refer to the electrical circuit diagrams
information Pre-catalyst and check the pre-catalyst temperature
temperature sensor sensor circuits for short circuit to ground
circuit short circuit to Check and install a new pre-catalyst
ground temperature sensor as required
Pre-catalyst
temperature sensor
failure

P2033- Exhaust Gas Temperature Pre-catalyst Check the pre-catalyst temperature


00 Sensor Circuit High Bank temperature sensor sensor for contamination
1 Sensor 2 - No sub type contaminated Refer to the electrical circuit diagrams
information Pre-catalyst and check the pre-catalyst temperature
temperature sensor sensor circuits for short circuit to power
circuit short circuit to Check and install a new pre-catalyst
power temperature sensor as required
Pre-catalyst
temperature sensor
failure

P2084- Exhaust Gas Temperature The engine control Refer to the electrical circuit diagrams
64 Sensor Circuit module detected and check connections are secure and
Range/Performance Bank 1 plausibility failures wiring integrity
Sensor 2 - Signal Pre-catalyst Check and install a new pre-catalyst
plausibility failure temperature sensor temperature sensor as required
circuit short circuit to
power, short circuit to
ground, open circuit
Pre-catalyst
temperature sensor
failure

P2121- Throttle/Pedal Position Accelerator pedal Refer to the electrical circuit diagrams
1F Sensor/Switch D Circuit position sensor 1 and check accelerator pedal position
Range/Performance - circuit high resistance sensor 1 circuit for high resistance
Circuit intermittent
P2121- Throttle/Pedal Position Harness fault Refer to the electrical circuit diagrams
87 Sensor/Switch D Circuit accelerator pedal and check the accelerator pedal position
Range/Performance - position sensor circuit sensor circuits, for short circuit to
Missing message Accelerator pedal power, short circuit to ground, open
position sensor failure circuit
Check and install a new accelerator
pedal position sensor as required

P2122- Throttle/Pedal Position Diagnostic fault check Refer to the electrical circuit diagrams
00 Sensor/Switch D Circuit of short circuit to and check the reference voltage and
Low - No sub type ground, signal range ground connections to the accelerator
information check low for pedal position sensor
acceleration pedal Check accelerator pedal position signal
signal 1 circuits for short circuit to ground.
Accelerator pedal Repair harness as required. Clear DTC
position sensor circuit and retest
short circuit to ground Check and install a new accelerator
Accelerator pedal pedal position sensor as required
position sensor failure

P2123- Throttle/Pedal Position Diagnostic fault check Refer to the electrical circuit diagrams
00 Sensor/Switch D Circuit of short circuit to and check the reference voltage and
High - No sub type power, signal range ground connections to the accelerator
information check high for pedal position sensor
acceleration pedal Check accelerator pedal position signal
signal 1 circuits for short circuit to power. Repair
Accelerator pedal harness as required. Clear DTC and
position sensor circuit retest
short circuit to power Check and install a new accelerator
Accelerator pedal pedal position sensor as required
position sensor failure

P2125- Throttle/Pedal Position The engine control Using the Jaguar Land Rover Approved
36 Sensor/Switch E Circuit - module detected Diagnostic Equipment check datalogger
Signal frequency too low excessive duration for signals, Accelerator Pedal Position E
one cycle of the output (0xF44A), Pedal Position Sensor
across a specified Voltage - Sensor 2 (0x0915)
sample size Refer to the electrical circuit diagrams
Harness fault and check the reference voltage and
accelerator pedal ground connections to the accelerator
position sensor circuit pedal position sensor
Accelerator pedal Check signal circuits for short circuit to
position sensor failure ground. Repair harness as required.
Clear DTC and retest
Check and install a new accelerator
pedal position sensor as required

P2125- Throttle/Pedal Position The engine control Using the Jaguar Land Rover Approved
37 Sensor/Switch E Circuit - module detected Diagnostic Equipment check datalogger
Signal frequency too high insufficient duration signals, Accelerator Pedal Position E
for one cycle of the (0xF44A), Pedal Position Sensor
output across a Voltage - Sensor 2 (0x0915)
specified sample size Refer to the electrical circuit diagrams
Harness fault and check the reference voltage and
accelerator pedal ground connections to the accelerator
position sensor circuit pedal position sensor
Accelerator pedal Check signal circuits for short circuit to
position sensor failure power. Repair harness as required. Clear
DTC and retest
Check and install a new accelerator
pedal position sensor as required

P2126- Throttle/Pedal Position Accelerator pedal Refer to the electrical circuit diagrams
1F Sensor/Switch E Circuit position sensor 2 and check accelerator pedal position
Range/Performance - circuit high resistance sensor 2 circuit for high resistance
Circuit intermittent
P2127- Throttle/Pedal Position Diagnostic fault check Using the Jaguar Land Rover Approved
00 Sensor/Switch E Circuit of short circuit to Diagnostic Equipment check datalogger
Low - No sub type ground, signal range signals, Accelerator Pedal Position E
information check low for (0xF44A), Pedal Position Sensor
acceleration pedal Voltage - Sensor 2 (0x0915)
signal 2 Refer to the electrical circuit diagrams
Accelerator pedal and check the reference voltage and
position sensor circuit ground connections to the accelerator
short circuit to ground pedal position sensor
Accelerator pedal Check signal circuits for short circuit to
position sensor failure ground. Repair harness as required.
Clear DTC and retest
Check and install a new accelerator
pedal position sensor as required

P2128- Throttle/Pedal Position Diagnostic fault check Using the Jaguar Land Rover Approved
00 Sensor/Switch E Circuit of short circuit to Diagnostic Equipment check datalogger
High - No sub type power, signal range signals, Accelerator Pedal Position E
information check high for (0xF44A), Pedal Position Sensor
acceleration pedal Voltage - Sensor 2 (0x0915)
signal 2 Refer to the electrical circuit diagrams
Accelerator pedal and check the reference voltage and
position sensor circuit ground connections to the accelerator
short circuit to power pedal position sensor
Accelerator pedal Check signal circuits for short circuit to
position sensor failure power. Repair harness as required. Clear
DTC and retest
Check and install a new accelerator
pedal position sensor as required

P2138- Throttle/Pedal Position Diagnostic fault check Refer to the electrical circuit diagrams
00 Sensor/Switch D / E of synchronism and check connections are secure and
Voltage Correlation - No between both wiring integrity
sub type information acceleration pedal Refer to the electrical circuit diagrams
signals and check accelerator pedal position
Accelerator pedal sensor 1 circuit for short circuit to
position sensor circuit power, short circuit to ground, open
short circuit to power, circuit. Refer to the electrical circuit
short circuit to ground, diagrams and check accelerator pedal
open circuit position sensor 2 circuit for short circuit
Accelerator pedal to power, short circuit to ground, open
position sensor failure circuit. Repair harness as required. Clear
DTC and retest
Check and install a new accelerator
pedal position sensor as required
P2138- Throttle/Pedal Position The engine control Refer to the electrical circuit diagrams
64 Sensor/Switch D / E module detected and check accelerator pedal position
Voltage Correlation - plausibility failures sensor 1 circuit for short circuit to
Signal plausibility failure Accelerator pedal power, short circuit to ground, open
position sensor circuit circuit. Refer to the electrical circuit
short circuit to power, diagrams and check accelerator pedal
short circuit to ground, position sensor 2 circuit for short circuit
open circuit to power, short circuit to ground, open
Accelerator pedal circuit. Repair harness as required. Clear
position sensor failure DTC and retest
Check and install a new accelerator
pedal position sensor as required

P2138- Throttle/Pedal Position The engine control Refer to the electrical circuit diagrams
67 Sensor/Switch D / E module did not see the and check accelerator pedal position
Voltage Correlation - correct change of a sensor 1 circuit for short circuit to
Signal incorrect after event parameter or group of power, short circuit to ground, open
parameters in response circuit. Refer to the electrical circuit
to a particular event diagrams and check accelerator pedal
Accelerator pedal position sensor 2 circuit for short circuit
position sensor circuit to power, short circuit to ground, open
short circuit to power, circuit. Repair harness as required. Clear
short circuit to ground, DTC and retest
open circuit Check and install a new accelerator
Accelerator pedal pedal position sensor as required
position sensor failure

P2141- Exhaust Gas Recirculation Electric throttle Using the Jaguar Land Rover Approved
00 Throttle Control Circuit A control circuit short Diagnostic Equipment check datalogger
Low - No sub type circuit to ground signals, Electric Throttle Actuator
information Electric throttle unit (0x030B), Electric Throttle (0xF44C).
failure Check the electric throttle unit responds
to the commanded position
Refer to the electrical circuit diagrams
and check electric throttle unit control
circuit for short circuit to ground
Check and install a new electric throttle
unit as required

P2142- Exhaust Gas Recirculation Electric throttle Using the Jaguar Land Rover Approved
00 Throttle Control Circuit A control circuit short Diagnostic Equipment check datalogger
High - No sub type circuit to power signals, Electric Throttle Actuator
information Electric throttle unit (0x030B), Electric Throttle (0xF44C).
failure Check the electric throttle unit responds
to the commanded position
Refer to the electrical circuit diagrams
and check electric throttle unit control
circuit for short circuit to power
Check and install a new electric throttle
unit as required

P2195- O2 Sensor Signal The analog signal for Check for fuel and injector related
00 Biased/Stuck Lean - Bank the O2 ratio from the DTCs and repair these first. Clear DTC
1, Sensor 1 - No sub type sensor during the and retest
information normal operation Check for air leaks at exhaust manifold,
exceeds the maximum downpipe, pre catalyst heated oxygen
threshold value sensor
Air leak at exhaust Refer to the electrical circuit diagrams
manifold, downpipe, and check pre catalyst heated oxygen
pre catalyst heated sensor for short circuit to ground, high
oxygen sensor resistance, open circuit. Repair harness
Pre catalyst heated as required. Clear DTC and retest
oxygen sensor circuit Check and install a new pre catalyst
short circuit to ground, heated oxygen sensor as required
short circuit to power,
high resistance, open
circuit
Pre catalyst heated
oxygen sensor failure

P2228- Barometric Pressure Barometric pressure Refer to the electrical circuit diagrams
00 Sensor A Circuit Low - No sensor is integral to and check engine control module power
sub type information the engine control and ground supply circuits
module Check and install a new engine control
Barometric pressure module as required
sensor 5 volt signal
circuit, below
minimum voltage
expected
Engine control module
failure

P2229- Barometric Pressure Barometric pressure Refer to the electrical circuit diagrams
00 Sensor A Circuit High - No sensor is integral to and check engine control module power
sub type information the engine control and ground supply circuits
module Check and install a new engine control
Barometric pressure module as required
sensor 5 volt signal
circuit, above
maximum voltage
expected
Engine control module
failure

P2245- O2 Sensor Reference Pre catalyst heated Check pre catalyst heated oxygen sensor
00 Voltage Circuit Low - oxygen sensor signal for damage
Bank 1, Sensor 1 - No sub calibration error Refer to the electrical circuit diagrams
type information Harness fault pre and check pre catalyst heated oxygen
catalyst heated oxygen sensor circuit for short circuit to power,
sensor short circuit to ground, open circuit
Pre catalyst heated Check pre catalyst heated oxygen sensor
oxygen sensor failure harness for signs of damage caused by
Engine control module chaffing or heat
failure Check and install a new pre catalyst
heated oxygen sensor as required
Check and install a new engine control
module as required

P2246- O2 Sensor Reference Pre catalyst heated Check pre catalyst heated oxygen sensor
00 Voltage Circuit High - oxygen sensor signal for damage
Bank 1, Sensor 1 - No sub calibration error Refer to the electrical circuit diagrams
type information Harness fault pre and check pre catalyst heated oxygen
catalyst heated oxygen sensor circuit for short circuit to power,
sensor short circuit to ground, open circuit
Pre catalyst heated Check pre catalyst heated oxygen sensor
oxygen sensor failure harness for signs of damage caused by
Engine control module chaffing or heat
failure Check and install a new pre catalyst
heated oxygen sensor as required
Check and install a new engine control
module as required

P2263- Turbocharger/Supercharger The engine control NOTE:


21 Boost System Performance module measured a
- Signal amplitude < signal voltage below a Using the Jaguar Land Rover Approved
minimum specified range but not Diagnostic Equipment perform the (Turbo,
necessarily a short EGR and air path dynamic test) routine
circuit to ground
Intake system air leak Check intake system for leaks and
or blockage blockages
Charge air system leak Check charge air system for leaks and
or blockage blockages. Check for related DTCs
Manifold absolute Refer to the electrical circuit diagrams
pressure sensor circuit and check manifold absolute pressure
short circuit to power, sensor circuit for short circuit to power,
ground, open circuit ground, open circuit. Repair harness as
Manifold absolute required
pressure sensor failure Check and install new manifold absolute
Variable geometry pressure sensor as required
turbocharger actuator Check turbocharger actuator rod
sticking connection and oil seals
Turbocharger failure Check and install new variable geometry
turbocharger actuator as required. Check
install new turbocharger as required

P2263- Turbocharger/Supercharger The engine control NOTE:


22 Boost System Performance module measured a
- Signal amplitude > signal voltage above a Using the Jaguar Land Rover Approved
maximum specified range but not Diagnostic Equipment perform the (Turbo,
necessarily a short EGR and air path dynamic test) routine
circuit to power, gain
too high Check intake system for leaks and
Intake system air leak blockages
or blockage Check charge air system for leaks and
Charge air system leak blockages. Check for related DTCs
or blockage Refer to the electrical circuit diagrams
Manifold absolute and check manifold absolute pressure
pressure sensor circuit sensor circuit for short circuit to power,
short circuit to power, ground, open circuit. Repair harness as
ground, open circuit required
Manifold absolute Check and install new manifold absolute
pressure sensor failure pressure sensor as required
Variable geometry Check turbocharger actuator rod
turbocharger actuator connection and oil seals
sticking Check and install new variable geometry
Turbocharger failure turbocharger actuator as required. Check
install new turbocharger as required

P2264- Water in Fuel Sensor Fuel supply Refer to the workshop manual and
00 Circuit - No sub type incorrect/contaminated check the fuel system to ensure there is
information Harness failure - an adequate fuel level in the tank and
Water in fuel sensor the system is not leaking fuel or
circuit suffering from air ingress. Check the
Battery junction box fuel for contamination by other fluids
power distribution (petrol or water)
fault Refer to the electrical circuit diagrams
Water in fuel sensor and check the water in fuel sensor signal
failure circuit between the sensor and the
engine control module for short circuit
to ground, short circuit to power, open
circuit, high resistance, intermittent
faults. Repair harness as required
Refer to the electrical wiring diagrams
and check the water in fuel sensor power
supply from the battery junction box for
high resistance, open circuit, short
circuit to ground. Check the water in
fuel sensor ground supply circuit for
high resistance, open circuit, short
circuit to power. Check the voltage
supply from the battery junction box
Check and install a new water in fuel
sensor

P2269- Water in Fuel Condition - Water in fuel Drain water from fuel filter housing.
68 Event information Water in fuel sensor Clear DTC, wait 30 seconds and retest
circuit short circuit to Refer to the electrical circuit diagrams
power, open circuit and check water in fuel sensor circuit for
Water in fuel sensor short circuit to power, open circuit
failure Check and install a new water in fuel
sensor as required

P226B- Turbocharger/Supercharger NOTE: Check for turbocharger related DTCs


00 Boost Pressure Too High - and repair these first. Clear DTC and
Mechanical" - No sub type The engine will shutdown retest
information when this DTC is set Using the Jaguar Land Rover Approved
Diagnostic Equipment perform routine -
This DTC is set when Inline diagnostic unit 2 diagnostic test -
overboost shut down is Turbocharger
active. This means that Check engine oil level, correct as
the vehicle has lost required
control of boost. The Check injectors for leakage
engine is shut down as Check air intake system for excessive
a safety precaution oil
Incorrect engine oil
level - Too high
Variable geometry
turbocharger vanes
stuck closed
Injector leakage

P2297- O2 Sensor Out of Range Oxygen concentration Check for fuel / injector related DTCs
00 During Deceleration Bank implausibly high in repair these first. Clear DTCs and retest
1, Sensor 1 - No sub type overrun Check for mass air flow related DTCs
information Oxygen concentration and repair these first. Clear DTCs and
implausibly low in retest
overrun Refer to the electrical circuit diagrams
Fuel injector failures and check pre catalyst heated oxygen
Mass air flow sensor sensor circuit for short circuit to power,
failures short circuit to ground, open circuit
Harness fault pre Check pre catalyst heated oxygen sensor
catalyst heated oxygen harness for signs of damage caused by
sensor chaffing or heat
Pre catalyst heated Check pre catalyst heated oxygen sensor
oxygen sensor failure for damage
Check and install a new pre catalyst
heated oxygen sensor as required

P2299- Brake Pedal Brake pedal main Refer to the electrical circuit diagrams
68 Position/Accelerator Pedal switch circuit short and check brake pedal main switch
Position Incompatible - circuit to ground, open circuit for short circuit to ground, open
Event information circuit circuit. Repair harness as required.
Brake pedal redundant Refer to the electrical circuit diagrams
switch circuit short and check brake pedal redundant switch
circuit to ground circuit for short circuit to ground
Brake pedal switch Repair wiring harness as required, clear
incorrect adjustment DTC. Start the engine press the brake
Brake pedal switch pedal, using maximum travel for greater
failure than 1 second taking care not to press
Brake pedal pressed the accelerator pedal. Check the system
by driver at same time is operating correctly and the DTC does
as accelerator pedal not return
pressed Check and adjust brake switch as
required
Check and install new brake pedal
switch as required

P242A- Exhaust Gas Temperature Post catalyst Check the post catalyst temperature
00 Sensor Circuit Bank 1 temperature sensor sensor for contamination
Sensor 3 - No sub type contaminated Refer to the electrical circuit diagrams
information Post catalyst and check the post catalyst temperature
temperature sensor sensor circuits for short circuit to power,
circuit short circuit to short circuit to ground, open circuit,
power, short circuit to high resistance
ground, open circuit, Check and install a new post catalyst
high resistance temperature sensor as required
Post catalyst
temperature sensor
failure

P242B- Exhaust Gas Temperature The engine control Refer to the electrical circuit diagrams
64 Sensor Circuit module detected and check the post catalyst temperature
Range/Performance Bank 1 plausibility failures sensor circuits for short circuit to power,
Sensor 3 - Signal Post catalyst short circuit to ground, open circuit,
plausibility failure temperature sensor high resistance
circuit short circuit to Check post catalyst temperature sensor
power, short circuit to for contamination
ground, open circuit, Check and install a new post catalyst
high resistance temperature sensor as required
Post catalyst
temperature sensor
contaminated
Post catalyst
temperature sensor
failure

P242B- Exhaust Gas Temperature The engine control Check the catalyst for damage
98 Sensor Circuit module detected that Check intake air system for leakage
Range/Performance Bank 1 the temperature is too Check the diesel particulate filter for
Sensor 3 - Component or high for the correct damage
system over temperature operation of the Check post catalyst temperature sensor
component or system for contamination
Catalyst damaged Refer to the electrical circuit diagrams
Intake air system leak and check the post catalyst temperature
Diesel particulate filter sensor circuits for short circuit to power,
damaged short circuit to ground, open circuit,
Post catalyst high resistance
temperature sensor Check and install a new post catalyst
contaminated temperature sensor as required
Post catalyst
temperature sensor
circuit short circuit to
power, short circuit to
ground, open circuit,
high resistance
Post catalyst
temperature sensor
failure

P242C- Exhaust Gas Temperature Post catalyst Check the post catalyst temperature
00 Sensor Circuit Low Bank 1 temperature sensor sensor for contamination
Sensor 3 - No sub type contaminated Refer to the electrical circuit diagrams
information Post catalyst and check the post catalyst temperature
temperature sensor sensor circuits for short circuit to ground
circuit short circuit to Check and install a new post catalyst
ground temperature sensor as required
Post catalyst
temperature sensor
failure

P242D- Exhaust Gas Temperature Post catalyst Check the post catalyst temperature
00 Sensor Circuit High Bank temperature sensor sensor for contamination
1 Sensor 3 - No sub type contaminated Refer to the electrical circuit diagrams
information Post catalyst and check the post catalyst temperature
temperature sensor sensor circuits for short circuit to power
circuit short circuit to Check and install a new post catalyst
power temperature sensor as required
Post catalyst
temperature sensor
failure

P242F- Diesel Particulate Filter Maximum ash load Contact dealer technical support
00 (DPF) Restriction - Ash
Accumulation (Bank 1) -
No sub type information
P244A- Diesel Particulate Filter Destroyed particulate Carry out pinpoint test A.For additional
96 (DPF) Differential Pressure filter information, refer to: Diesel Particulate
Too Low(Bank1) - Filter (309-00A Exhaust System - TD4
Component internal failure 2.2L Diesel, Diagnosis and Testing).
P2454- Diesel Particulate Filter Harness fault - Diesel NOTE:
00 (DPF) Pressure Sensor A particulate filter,
Circuit Low - No sub type differential pressure If a new diesel particulate filter pressure
information sensor sensor or hose lines have been installed or
Diesel particulate incorrectly routed, or any pressure sensor
filter, differential circuit repairs carried out, the engine control
pressure sensor failure module must learn - store the new diesel
particulate filter pressure sensor offset value.
The following conditions must be achieved to
allow the diesel particulate filter pressure
sensor offset value to be learnt - stored: Using
the Jaguar Land Rover Approved Diagnostic
Equipment, clear DTCs from engine control
module, then monitor the datalogger signal
'sump oil temperature measured' ensuring a
minimum of 50 degrees C is achieved. Start
engine, run above 500rpm for 2 minutes, then
a further 30 seconds at idle. Ensure the engine
cooling fan is not running. Set vehicle in park
- set ignition status to off. Wait 30 seconds for
the engine control module to power down,
learn - store diesel particulate filter pressure
sensor offset value. This process must be
carried out six times, to allow a large negative
offset value to adapt back to 0 hPa

Using the Jaguar Land Rover Approved


Diagnostic Equipment check datalogger
signals, diesel particulate filter -
Differential Pressure Sensor Voltage -
Bank 1 - (0x03DB). This DTC is set
when the particulate pressure sensor
fails a plausibility check
Refer to the workshop manual and
check the particulate filter and sensor
for obvious signs of damage
Check the sensor harness for chaffing or
heat damage
Refer to the electrical circuit diagrams
and check the diesel particulate filter,
differential pressure sensor signal circuit
for open circuit, short circuit to ground,
short to other circuits
Check the sensor ground circuit for open
circuit, short circuit to power, high
resistance
Check the sensor power supply circuit
for open circuit, short circuit to ground,
high resistance
Repair wiring as required, if there are no
wiring faults. Check and install a new
diesel particulate filter, differential
pressure sensor as required

P2455- Diesel Particulate Filter Harness fault - Diesel NOTE:


00 (DPF) Pressure Sensor A particulate filter,
Circuit High - No sub type differential pressure If a new diesel particulate filter pressure
information sensor sensor or hose lines have been installed or
Diesel particulate incorrectly routed, or any pressure sensor
filter, differential circuit repairs carried out, the engine control
pressure sensor failure module must learn - store the new diesel
particulate filter pressure sensor offset value.
The following conditions must be achieved to
allow the diesel particulate filter pressure
sensor offset value to be learnt - stored: Using
the Jaguar Land Rover Approved Diagnostic
Equipment, clear DTCs from engine control
module, then monitor the datalogger signal
'sump oil temperature measured' ensuring a
minimum of 50 degrees C is achieved. Start
engine, run above 500rpm for 2 minutes, then
a further 30 seconds at idle. Ensure the engine
cooling fan is not running. Set vehicle in park
- set ignition status to off. Wait 30 seconds for
the engine control module to power down,
learn - store diesel particulate filter pressure
sensor offset value. This process must be
carried out six times, to allow a large negative
offset value to adapt back to 0 hPa

Using the Jaguar Land Rover Approved


Diagnostic Equipment check datalogger
signals, diesel particulate filter -
Differential Pressure Sensor Voltage -
Bank 1 - (0x03DB). This DTC is set
when the particulate pressure sensor
fails a plausibility check
Refer to the workshop manual and
check the particulate filter and sensor
for obvious signs of damage
Check the sensor harness for chaffing or
heat damage
Refer to the electrical circuit diagrams
and check the diesel particulate filter,
differential pressure sensor signal circuit
for open circuit, short circuit to ground,
short to other circuits
Check the sensor ground circuit for open
circuit, short circuit to power, high
resistance
Check the sensor power supply circuit
for open circuit, short circuit to ground,
high resistance
Repair wiring as required, if there are no
wiring faults. Check and install a new
diesel particulate filter, differential
pressure sensor as required

P2456- Diesel Particulate Filter Diesel particulate NOTE:


00 (DPF) Pressure Sensor A filter, differential
Circuit Intermittent/Erratic pressure sensor hoses If a new diesel particulate filter pressure
- No sub type information crushed, blocked, split sensor or hose lines have been installed or
Diesel particulate incorrectly routed, or any pressure sensor
filter, differential circuit repairs carried out, the engine control
pressure sensor failure module must learn - store the new diesel
particulate filter pressure sensor offset value.
The following conditions must be achieved to
allow the diesel particulate filter pressure
sensor offset value to be learnt - stored: Using
the Jaguar Land Rover Approved Diagnostic
Equipment, clear DTCs from engine control
module, then monitor the datalogger signal
'sump oil temperature measured' ensuring a
minimum of 50 degrees C is achieved. Start
engine, run above 500rpm for 2 minutes, then
a further 30 seconds at idle. Ensure the engine
cooling fan is not running. Set vehicle in park
- set ignition status to off. Wait 30 seconds for
the engine control module to power down,
learn - store diesel particulate filter pressure
sensor offset value. This process must be
carried out six times, to allow a large negative
offset value to adapt back to 0 hPa

Check diesel particulate filter,


differential pressure sensor hoses for
crushed, blocked, split. Replace as
required
Check and install a new diesel
particulate filter, differential pressure
sensor as required

P2458- Diesel Particulate Filter Permanent NOTE:


66 (DPF) Regeneration regeneration
Duration (Bank 1) - Signal This code is enabled for JLR engineering
has too many transitions / detailed diagnostics only. No further action
events should be taken

Using the Jaguar Land Rover Approved


Diagnostic Equipment, check for related
DTCs and refer to the relevant DTC
Index

P2459- Diesel Particulate Filter Blocked regeneration NOTE:


65 (DPF) Regeneration Customer driving
Frequency (Bank 1) - routine does not allow If DTC is P2459-65 or AMBER DPF FULL
Signal has too few the system to clean the REFER TO HANDBOOK message is
transitions / events particulate filter displayed with no other reported messages. No
repair is required, if the vehicle is driven on a
highway AS DIRECTED IN THE
HANDBOOK then the light will be
extinguished - the system self healed, nothing
more than this is required

Refer to the diesel particulate filter


regeneration procedure at the bottom of
the DTC index
Advise customer of driving routine
required to regenerate diesel particulate
filter as stated in the vehicle handbook
P245A- Exhaust Gas Recirculation The engine control Using the Jaguar Land Rover Approved
11 Cooler Bypass Control module has detected a Diagnostic Equipment check datalogger
Circuit (Bank 1) - Circuit ground measurement signals, Exhaust Gas Recirculation
short to ground for a period longer Cooler Bypass Valve Duty Cycle
than expected or has (0x03C5)
detected a ground Refer to the electrical circuit diagrams
measurement when and check exhaust gas recirculation
another value was cooler bypass valve circuit for short
expected circuit to ground
Exhaust gas
recirculation cooler
bypass valve circuit
short circuit to ground

P245A- Exhaust Gas Recirculation The engine control Using the Jaguar Land Rover Approved
12 Cooler Bypass Control module has detected a Diagnostic Equipment check datalogger
Circuit (Bank 1) - Circuit vehicle power signals, Exhaust Gas Recirculation
short to battery measurement for a Cooler Bypass Valve Duty Cycle
period longer than (0x03C5)
expected or has Refer to the electrical circuit diagrams
detected a vehicle and check exhaust gas recirculation
power measurement cooler bypass valve circuit for short
when another value circuit to power
was expected
Exhaust gas
recirculation cooler
bypass valve circuit
short circuit to power

P245A- Exhaust Gas Recirculation The engine control Using the Jaguar Land Rover Approved
13 Cooler Bypass Control module has Diagnostic Equipment check datalogger
Circuit (Bank 1) - Circuit determined an open signals, Exhaust Gas Recirculation
open circuit via lack of bias Cooler Bypass Valve Duty Cycle
voltage, low current (0x03C5)
flow, no change in the Refer to the electrical circuit diagrams
state of an input in and check exhaust gas recirculation
response to an output cooler bypass valve circuit, for open
Exhaust gas circuit
recirculation cooler
bypass valve circuit,
open circuit

P245A- Exhaust Gas Recirculation The engine control Check for sticking or damaged exhaust
77 Cooler Bypass Control module is unable to gas recirculation cooler bypass valve
Circuit (Bank 1) - command a motor, Refer to the electrical circuit diagrams
Commanded position not solenoid or relay, to and check exhaust gas recirculation
reachable move a piece of valve position sensor circuit, for short
equipment to the circuit to power, short circuit to ground,
commanded position open circuit, high resistance
either due to a failure Check and install a new exhaust gas
in the actuator or its recirculation bypass position sensor as
mechanical required
environment Check and install a new exhaust gas
Diagnostic fault check recirculation cooler bypass valve as
for error condition required
between exhaust gas
recirculation cooler
bypass valve desired
and actual positions
Exhaust gas
recirculation cooler
bypass valve is
demanded to be open,
but the actuator is not
open
Exhaust gas
recirculation cooler
bypass valve is
demanded to be
closed, but the
actuator is not closed
Exhaust gas
recirculation valve
position sensor failure

P245B- Exhaust Gas Recirculation The engine control Refer to the electrical circuit diagrams
4B Cooler Bypass Control module detected an and check exhaust gas recirculation
Circuit Range/Performance internal temperature cooler bypass valve actuator circuit for
(Bank 1) - Over above the expected short circuit to power, short circuit to
temperature range ground, short circuit to another circuit
Exhaust gas
recirculation electric
actuator circuit, over
temperature. Sticking
valve

P2463- Diesel Particulate Filter Maximum soot mass Carry out pinpoint test B.For additional
00 (DPF) Restriction - Soot information, refer to: Diesel Particulate
Accumulation (Bank 1) - Filter (309-00A Exhaust System - TD4
No sub type information 2.2L Diesel, Diagnosis and Testing).

P2494- Exhaust Gas Recirculation Exhaust gas NOTE:


00 Cooler Bypass Position recirculation cooler
Sensor Circuit Low (Bank bypass valve position Using the Jaguar Land Rover Approved
1) - No sub type sensor 5 volt signal Diagnostic Equipment perform the (Turbo,
information circuit, below EGR and air path dynamic test) routine
minimum voltage
expected Refer to the electrical circuit diagrams
Exhaust gas and check exhaust gas recirculation
recirculation cooler cooler bypass valve position sensor 5
bypass valve position volt signal circuit for short circuit to
sensor failure ground
Check and install a new exhaust gas
recirculation cooler bypass valve
position sensor as required

P2495- Exhaust Gas Recirculation Exhaust gas Refer to the electrical circuit diagrams
00 Cooler Bypass Position recirculation cooler and check exhaust gas recirculation
Sensor Circuit High (Bank bypass valve position cooler bypass valve position sensor 5
1) - No sub type sensor 5 volt signal volt signal circuit for short circuit to
information circuit, above power
maximum voltage Check and install a new exhaust gas
expected recirculation cooler bypass valve
Exhaust gas position sensor as required
recirculation cooler
bypass valve position
sensor failure

P250A- Engine Oil Level Sensor The engine control Refer to the electrical circuit diagrams
16 Circuit - Circuit voltage module measured a and check oil level sensor circuit for
below threshold voltage below a short circuit to ground
specified range but not Check and install a new oil level sensor
necessarily a short as required
circuit to ground
Oil level sensor circuit
short circuit to ground
Oil level sensor failure

P250A- Engine Oil Level Sensor The engine control Refer to the electrical circuit diagrams
17 Circuit - Circuit voltage module measured a and check oil level sensor circuit for
above threshold voltage above a short circuit to power, open circuit
specified range but not Check and install new oil level sensor as
necessarily a short required
circuit to power
Oil level sensor circuit
short circuit to power,
open circuit
Oil level sensor failure

P250A- Engine Oil Level Sensor The engine control Check the oil level is correct and the oil
36 Circuit - Signal frequency module detected does not appear contaminated. Renew or
too low excessive duration for top up oil as required
one cycle of the output Using the Jaguar Land Rover Approved
across a specified Diagnostic Equipment check datalogger
sample size signal - Engine Oil Level - Measured -
Oil contaminated or (0x03E6)
level incorrect Refer to the electrical circuit diagrams
Oil level sensor circuit and check oil level sensor circuit for
short circuit to ground short circuit to ground
Oil level sensor failure Check and install new oil level sensor as
required

P250A- Engine Oil Level Sensor The engine control Check the oil level is correct and the oil
37 Circuit - Signal frequency module detected does not appear contaminated. Renew or
too high insufficient duration top up oil as required
for one cycle of the Using the Jaguar Land Rover Approved
output across a Diagnostic Equipment check datalogger
specified sample size signal - Engine Oil Level - Measured -
Oil contaminated or (0x03E6)
level incorrect Refer to the electrical circuit diagrams
Oil level sensor circuit and check oil level sensor circuit for
short circuit to power short circuit to power
Oil level sensor failure Check and install new oil level sensor as
required

P250A- Engine Oil Level Sensor Oil contaminated or Check the oil level is correct and the oil
38 Circuit - Signal frequency level incorrect does not appear contaminated. Renew or
incorrect Oil level sensor circuit top up oil as required
short circuit to power, Using the Jaguar Land Rover Approved
short circuit to ground, Diagnostic Equipment check datalogger
open circuit, high signal - Engine Oil Level - Measured -
resistance (0x03E6)
Oil level sensor failure Refer to the electrical circuit diagrams
and check oil level sensor circuit for
short circuit to power, short circuit to
ground, open circuit, high resistance
Check and install new oil level sensor as
required

P250A- Engine Oil Level Sensor Oil level sensor circuit Using the Jaguar Land Rover Approved
47 Circuit - Watchdog / safety short circuit to ground, Diagnostic Equipment check datalogger
MicroController failure short circuit to power, signal - Engine Oil Level - Measured -
high resistance, open (0x03E6)
circuit Refer to the electrical circuit diagrams
Oil level sensor failure and check oil level sensor circuit for
short circuit to ground, short circuit to
power, high resistance, open circuit.
Repair wiring harness as required, clear
DTC and retest system
Check and install new oil level sensor as
required

P250A- Engine Oil Level Sensor The engine control Using the Jaguar Land Rover Approved
92 Circuit - Performance or module has detected Diagnostic Equipment check datalogger
incorrect operation that the component signal - Engine Oil Level - Measured -
performance is outside (0x03E6)
its expected range or Refer to the electrical circuit diagrams
operating in an and check oil level sensor circuit for
incorrect way short circuit to ground, short circuit to
Oil level sensor circuit power, high resistance, open circuit.
short circuit to ground, Repair wiring harness as required, clear
short circuit to power, DTC and retest system
high resistance, open Check and install new oil level sensor as
circuit required
Oil level sensor failure

P250B- Engine Oil Level Sensor The engine control Refer to the relevant section of the
16 Circuit Range/Performance module measured a workshop manual and correct the engine
- Circuit voltage below voltage below a oil level as required
threshold specified range but not Refer to the electrical circuit diagrams
necessarily a short and check oil level sensor circuit for
circuit to ground short circuit to power, short circuit to
Incorrect engine oil ground, open circuit
level Check and install new oil level sensor as
Oil level sensor circuit required
short circuit to power,
short circuit to ground,
open circuit
Oil level sensor failure

P250B- Engine Oil Level Sensor The engine control Refer to the relevant section of the
17 Circuit Range/Performance module measured a workshop manual and correct the engine
- Circuit voltage above voltage above a oil level as required
threshold specified range but not Refer to the electrical circuit diagrams
necessarily a short and check oil level sensor circuit for
circuit to power short circuit to power, short circuit to
Incorrect engine oil ground, open circuit
level Check and install new oil level sensor as
Oil level sensor circuit required
short circuit to power,
short circuit to ground,
open circuit
Oil level sensor failure

P250E- Engine Oil Level Sensor The engine control Refer to the relevant section of the
16 Circuit Intermittent/Erratic module measured a workshop manual and correct the engine
- Circuit voltage below voltage below a oil level as required
threshold specified range but not Refer to the electrical circuit diagrams
necessarily a short and check oil level sensor circuit for
circuit to ground short circuit to power, short circuit to
Incorrect engine oil ground, open circuit
level Check and install new oil level sensor as
Oil level sensor circuit required
short circuit to power,
short circuit to ground,
open circuit
Oil level sensor failure

P250E- Engine Oil Level Sensor The engine control Refer to the relevant section of the
17 Circuit Intermittent/Erratic module measured a workshop manual and correct the engine
- Circuit voltage above voltage above a oil level as required
threshold specified range but not Refer to the electrical circuit diagrams
necessarily a short and check oil level sensor circuit for
circuit to power short circuit to power, short circuit to
Incorrect engine oil ground, open circuit
level Check and install new oil level sensor as
Oil level sensor circuit required
short circuit to power,
short circuit to ground,
open circuit
Oil level sensor failure

P259E- Turbocharger "A" Boost NOTE: Using the Jaguar Land Rover Approved
73 Control Position At Low Diagnostic Equipment perform routine -
Limit - Actuator stuck This is a position control Inline diagnostic unit 2 diagnostic test -
closed diagnostic. It indicates that Turbocharger
the variable geometry Check variable geometry turbocharger
turbocharger actuator vane actuator mechanical linkage is correctly
has gone to fully closed installed and not broken or damaged
position when it should not Refer to the electrical circuit diagrams
and check the variable geometry turbine
The engine control vane actuator circuit for short circuit to
module did not detect ground, open circuit, high resistance
any motion upon Check and install a new variable
commanding the geometry turbine vane actuator as
operation of a motor, required
solenoid or relay to
open some piece of
equipment
Variable geometry
turbocharger actuator
mechanical linkage
failure
Variable geometry
turbine vane actuator
circuit, short circuit to
ground, open circuit,
high resistance
Variable geometry
turbine vane actuator
failure

P2601- Coolant Pump A Control The engine control Refer to the electrical circuit diagrams
11 Circuit Range/Performance module has detected a and check coolant pump relay circuit for
- Circuit short to ground ground measurement short circuit to ground
for a period longer
than expected or has
detected a ground
measurement when
another value was
expected
Coolant pump relay
circuit short circuit to
ground

P2601- Coolant Pump A Control The engine control Refer to the electrical circuit diagrams
12 Circuit Range/Performance module has detected a and check coolant pump relay circuit for
- Circuit short to battery vehicle power short circuit to power
measurement for a
period longer than
expected or has
detected a vehicle
power measurement
when another value
was expected
Coolant pump relay
circuit short circuit to
power

P2601- Coolant Pump A Control The engine control Refer to the electrical circuit diagrams
13 Circuit Range/Performance module has and check coolant pump relay circuit for
- Circuit open determined an open open circuit
circuit via lack of bias
voltage, low current
flow, no change in the
state of an input in
response to an output
Coolant pump relay
circuit open circuit

P2601- Coolant Pump A Control The engine control Refer to the electrical circuit diagrams
98 Circuit Range/Performance module detected that and check coolant pump relay circuit for
- Component or system the temperature is too short circuit to power
over temperature high for the correct
operation of the
component or system
Coolant pump relay
circuit short circuit to
power
P268C- Cylinder 1 Injector Data Injector calibration Using the Jaguar Land Rover Approved
00 Incompatible - No sub type data held in the engine Diagnostic Equipment reprogram the
information control module is injector codes
different to that read
from the injector
Injector calibration
data not stored /
programmed

P268C- Cylinder 1 Injector Data Injector calibration Using the Jaguar Land Rover Approved
51 Incompatible - Not data held in the engine Diagnostic Equipment reprogram the
programmed control module is injector codes
different to that read
from the injector
Injector calibration
data not stored /
programmed

P268D- Cylinder 2 Injector Data Injector calibration Using the Jaguar Land Rover Approved
00 Incompatible - No sub type data held in the engine Diagnostic Equipment reprogram the
information control module is injector codes
different to that read
from the injector
Injector calibration
data not stored /
programmed

P268D- Cylinder 2 Injector Data Injector calibration Using the Jaguar Land Rover Approved
51 Incompatible - Not data held in the engine Diagnostic Equipment reprogram the
programmed control module is injector codes
different to that read
from the injector
Injector calibration
data not stored /
programmed

P268E- Cylinder 3 Injector Data Injector calibration Using the Jaguar Land Rover Approved
00 Incompatible - No sub type data held in the engine Diagnostic Equipment reprogram the
information control module is injector codes
different to that read
from the injector
Injector calibration
data not stored /
programmed

P268E- Cylinder 3 Injector Data Injector calibration Using the Jaguar Land Rover Approved
51 Incompatible - Not data held in the engine Diagnostic Equipment reprogram the
programmed control module is injector codes
different to that read
from the injector
Injector calibration
data not stored /
programmed

P268F- Cylinder 4 Injector Data Injector calibration Using the Jaguar Land Rover Approved
00 Incompatible - No sub type data held in the engine Diagnostic Equipment reprogram the
information control module is injector codes
different to that read
from the injector
Injector calibration
data not stored /
programmed

P268F- Cylinder 4 Injector Data Injector calibration Using the Jaguar Land Rover Approved
51 Incompatible - Not data held in the engine Diagnostic Equipment reprogram the
programmed control module is injector codes
different to that read
from the injector
Injector calibration
data not stored /
programmed

P2A00- O2 Circuit Range / The engine control This DTC is set when the engine control
16 Performance (Bank 1, module measured a module detects the voltage on the trim
Sensor 1) - Circuit voltage voltage below a resistor circuit of the pre catalyst heated
below threshold specified range but not oxygen sensor is less than the voltage
necessarily a short threshold. This may be caused by the
circuit to ground pre catalyst heated oxygen sensor being
The calculated too cool to operate correctly
temperature of the pre Refer to the electrical circuit diagrams
catalyst heated oxygen and check pre catalyst heated oxygen
sensor was below the sensor circuit for short circuit to ground,
minimum threshold short circuit to power, high resistance,
Harness fault - Pre open circuit. Check all engine control
catalyst heated oxygen module power and ground supplies.
sensor circuit Repair harness as required. Clear DTC
Pre catalyst heated and retest
oxygen sensor failure Check the exhaust system and pre
catalyst heated oxygen sensor harness
for sign of mechanical damage. Install a
new pre catalyst heated oxygen sensor
as required

P2A00- O2 Circuit Range / The engine control This DTC is set when the engine control
17 Performance (Bank 1, module measured a module detects the voltage on the trim
Sensor 1) - Circuit voltage voltage above a resistor circuit of the pre catalyst heated
above threshold specified range but not oxygen sensor is greater than the voltage
necessarily a short threshold. This may be caused by the
circuit to power pre catalyst heated oxygen sensor being
The calculated too hot to operate correctly
temperature of the pre Refer to the electrical circuit diagrams
catalyst heated oxygen and check pre catalyst heated oxygen
sensor exceeded the sensor circuit for short circuit to ground,
maximum threshold short circuit to power, high resistance,
Harness fault - Pre open circuit. Check all engine control
catalyst heated oxygen module power and ground supplies.
sensor circuit Repair harness as required. Clear DTC
Pre catalyst heated and retest
oxygen sensor failure Check the exhaust system and pre
catalyst heated oxygen sensor harness
for sign of mechanical damage. Install a
new pre catalyst heated oxygen sensor
as required
U0001- High Speed CAN The engine control Refer to the electrical circuit diagrams
88 Communication Bus - Bus module has and check high speed CAN bus for short
off determined failures circuit to ground, short circuit to power,
where a data bus is not open circuit, short between CAN high
available and CAN low
High speed CAN bus
circuit short circuit to
ground, short circuit to
power, open circuit
High speed CAN bus
circuit, short between
CAN high and CAN
low

U0101- Lost Communication with The engine control Using the Jaguar Land Rover Approved
00 TCM - No sub type module has not Diagnostic Equipment, check
information received the expected transmission control module for DTCs
CAN signal from the and refer to the relevant DTC index
transmission control Using the Jaguar Land Rover Approved
module within the Diagnostic Equipment, complete a CAN
specified time interval network integrity test. Refer to the
CAN harness link electrical circuit diagrams and check
between engine transmission control module power and
control module and ground circuits for open circuit. Check
transmission control CAN harness between engine control
module network module and transmission control
malfunction module, repair as necessary

U0101- Lost Communication with The engine control Using the Jaguar Land Rover Approved
82 TCM - Alive / sequence module detected that a Diagnostic Equipment, check
counter incorrect / not signal was received transmission control module for DTCs
updated without the and refer to the relevant DTC index
corresponding rolling Using the Jaguar Land Rover Approved
count value being Diagnostic Equipment, complete a CAN
properly updated network integrity test. Refer to the
The engine control electrical circuit diagrams and check
module has not transmission control module power and
received the expected ground circuits for open circuit. Check
CAN signal from the CAN harness between engine control
transmission control module and transmission control
module within the module, repair as necessary
specified time interval
CAN harness link
between engine
control module and
transmission control
module network
malfunction

U0101- Lost Communication with The engine control Using the Jaguar Land Rover Approved
87 TCM - Missing message module has not Diagnostic Equipment, check
received the expected transmission control module for DTCs
CAN signal from the and refer to the relevant DTC index
transmission control Using the Jaguar Land Rover Approved
module within the Diagnostic Equipment, complete a CAN
specified time interval network integrity test. Refer to the
CAN harness link electrical circuit diagrams and check
between engine transmission control module power and
control module and ground circuits for open circuit. Check
transmission control CAN harness between engine control
module network module and transmission control
malfunction module, repair as necessary

U0103- Lost Communication With The engine control Using the Jaguar Land Rover Approved
00 Gear Shift Control Module module has not Diagnostic Equipment, check gear shift
A - No sub type received the expected control module for DTCs and refer to
information CAN signal from the the relevant DTC index
gear shift control Using the Jaguar Land Rover Approved
module within the Diagnostic Equipment, complete a CAN
specified time interval network integrity test. Refer to the
CAN harness link electrical circuit diagrams and check
between engine gear shift control module power and
control module and ground circuits for open circuit. Check
gear shift control CAN harness between engine control
module network module and gear shift control module,
malfunction repair as necessary

U0104- Lost Communication With The engine control Using the Jaguar Land Rover Approved
00 Cruise Control Module - module has not Diagnostic Equipment, check speed
No sub type information received the expected control module for DTCs and refer to
CAN signal from the the relevant DTC index
speed control module Using the Jaguar Land Rover Approved
within the specified Diagnostic Equipment, complete a CAN
time interval network integrity test. Refer to the
CAN harness link electrical circuit diagrams and check
between engine speed control module power and ground
control module and circuits for open circuit. Check CAN
speed control module harness between engine control module
network malfunction and speed control module, repair as
necessary

U0121- Lost Communication With The engine control Using the Jaguar Land Rover Approved
00 Anti-Lock Brake System module has not Diagnostic Equipment, check anti-lock
(ABS) Control Module - received the expected brake system control module for DTCs
No sub type information CAN signal from the and refer to the relevant DTC index
anti-lock brake system Using the Jaguar Land Rover Approved
control module within Diagnostic Equipment, complete a CAN
the specified time network integrity test. Refer to the
interval electrical circuit diagrams and check
CAN harness link anti-lock brake system control module
between engine power and ground circuits for open
control module and circuit. Check CAN harness between
anti-lock brake system engine control module and anti-lock
control module brake system control module, repair as
network malfunction necessary

U0126- Lost Communication With The engine control Using the Jaguar Land Rover Approved
00 Steering Angle Sensor module has not Diagnostic Equipment, check steering
Module - No sub type received the expected angle sensor module for DTCs and refer
information CAN signal from the to the relevant DTC index
steering angle sensor Using the Jaguar Land Rover Approved
module within the Diagnostic Equipment, complete a CAN
specified time interval network integrity test. Refer to the
CAN harness link electrical circuit diagrams and check
between engine steering angle sensor module power and
control module and ground circuits for open circuit. Check
steering angle sensor CAN harness between engine control
module network module and steering angle sensor
malfunction module, repair as necessary

U0128- Lost Communication With The engine control Using the Jaguar Land Rover Approved
00 Park Brake Control module has not Diagnostic Equipment, check parking
Module - No sub type received the expected brake control module for DTCs and
information CAN signal from the refer to the relevant DTC index
parking brake control Using the Jaguar Land Rover Approved
module within the Diagnostic Equipment, complete a CAN
specified time interval network integrity test. Refer to the
CAN harness link electrical circuit diagrams and check
between engine parking brake control module power and
control module and ground circuits for open circuit. Check
parking brake control CAN harness between engine control
module network module and parking brake control
malfunction module, repair as necessary

U0128- Lost Communication With The engine control Using the Jaguar Land Rover Approved
82 Park Brake Control module detected that a Diagnostic Equipment, check central
Module - Alive / sequence signal was received junction box for DTCs and refer to the
counter incorrect / not without the relevant DTC index
updated corresponding rolling Using the Jaguar Land Rover Approved
count value being Diagnostic Equipment, complete a CAN
properly updated network integrity test. Refer to the
The engine control electrical circuit diagrams and check
module has not central junction box power and ground
received the expected circuits for open circuit. Check CAN
CAN signal from the harness between engine control module
central junction box and central junction box, repair as
within the specified necessary
time interval
CAN harness link
between engine
control module and
central junction box
network malfunction

U0140- Lost Communication With The engine control Using the Jaguar Land Rover Approved
00 Body Control Module - No module has not Diagnostic Equipment, check central
sub type information received the expected junction box for DTCs and refer to the
CAN signal from the relevant DTC index
central junction box Using the Jaguar Land Rover Approved
within the specified Diagnostic Equipment, complete a CAN
time interval network integrity test. Refer to the
CAN harness link electrical circuit diagrams and check
between engine central junction box power and ground
control module and circuits for open circuit. Check CAN
central junction box harness between engine control module
network malfunction and central junction box, repair as
necessary
U0151- Lost Communication With The engine control Using the Jaguar Land Rover Approved
00 Restraints Control Module module has not Diagnostic Equipment, check restraints
- No sub type information received the expected control module for DTCs and refer to
CAN signal from the the relevant DTC index
restraints control Using the Jaguar Land Rover Approved
module within the Diagnostic Equipment, complete a CAN
specified time interval network integrity test. Refer to the
CAN harness link electrical circuit diagrams and check
between engine restraints control module power and
control module and ground circuits for open circuit. Check
restraints control CAN harness between engine control
module network module and restraints control module,
malfunction repair as necessary

U0151- Lost Communication With The hardwired crash Check the restraints control module for
08 Restraints Control Module event status signal to DTCs and refer to the relevant DTC
- Bus Signal / Message the engine control index
Failures module does not Refer to the electrical circuit diagrams
match the crash event and check hardwired crash status circuit
status signal sent to Refer to the electrical circuit diagrams
the engine control and check CAN circuits between engine
module over the CAN control module and restraints control
bus module
Both the hardwired
crash event status
signal and the crash
event status CAN
signal are unreliable

U0155- Lost Communication With The engine control Using the Jaguar Land Rover Approved
00 Instrument Panel Cluster module has not Diagnostic Equipment, check instrument
(IPC) Control Module - No received the expected cluster for DTCs and refer to the
sub type information CAN signal from the relevant DTC index
instrument cluster Using the Jaguar Land Rover Approved
within the specified Diagnostic Equipment, complete a CAN
time interval network integrity test. Refer to the
CAN harness link electrical circuit diagrams and check
between engine instrument cluster power and ground
control module and circuits for open circuit. Check CAN
instrument cluster harness between engine control module
network malfunction and instrument cluster, repair as
necessary

U0164- Lost Communication With The engine control Using the Jaguar Land Rover Approved
00 HVAC Control Module - module has not Diagnostic Equipment, check HVAC
No sub type information received the expected Control Module for DTCs and refer to
CAN signal from the the relevant DTC index
HVAC Control Using the Jaguar Land Rover Approved
Module within the Diagnostic Equipment, complete a CAN
specified time interval network integrity test. Refer to the
CAN harness link electrical circuit diagrams and check
between engine HVAC Control Module power and
control module and ground circuits for open circuit. Check
HVAC Control CAN harness between engine control
Module network module and HVAC Control Module,
malfunction repair as necessary
U0167- Lost Communication With Engine control module Using the Jaguar Land Rover Approved
00 Vehicle Immobilizer identity transfer failed Diagnostic Equipment, check
Control Module - No sub immobilizer control module for DTCs
type information and refer to the relevant DTC index
Using the Jaguar Land Rover Approved
Diagnostic Equipment, complete a CAN
network integrity test. Refer to the
electrical circuit diagrams and check the
power supply and ground connections to
the immobilizer control module. Repair
wiring harness as required
Check and install a new immobilizer
control module as required

U0300- Internal Control Module Car configuration Using the Jaguar Land Rover Approved
00 Software Incompatibility - signal not received Diagnostic Equipment check/amend the
No sub type information Car configuration file car configuration file
incorrect

U0402- Invalid Data Received DTC is logged for Refer to the electrical circuit diagrams
00 from TCM - No sub type coding error when and check connections are secure and
information selected coding is not wiring integrity
working

U0405- Invalid Data Received Speed control system Using the Jaguar Land Rover Approved
68 From Cruise Control fault Diagnostic Equipment, check speed
Module - Event Clock spring failure control module for DTCs and refer to
information the relevant DTC index
Using the Jaguar Land Rover Approved
Diagnostic Equipment, complete a CAN
network integrity test. Refer to the
electrical circuit diagrams and check the
power supply and ground connections to
the speed control module. Repair wiring
harness as required
Refer to the electrical circuit diagrams
and check the clock spring wiring for
intermittent connections
Check and install a new speed control
module as required

U0405- Invalid Data Received The engine control Check speed control buttons are not
82 From Cruise Control module detected that a jammed/contaminated/damaged
Module - Alive / sequence signal was received Using the Jaguar Land Rover Approved
counter incorrect / not without the Diagnostic Equipment, check speed
updated corresponding rolling control module for DTCs and refer to
count value being the relevant DTC index
properly updated Using the Jaguar Land Rover Approved
Speed control system Diagnostic Equipment, complete a CAN
fault network integrity test. Refer to the
Harness fault - CAN electrical circuit diagrams and check the
circuits power supply and ground connections to
Harness fault - Speed the speed control module. Repair wiring
control module power harness as required
supply or ground Check and install a new speed control
failure module as required
U0405- Invalid Data Received The engine control Using the Jaguar Land Rover Approved
84 From Cruise Control module has Diagnostic Equipment, check speed
Module - Signal below determined failures control module for DTCs and refer to
allowable range where some circuit the relevant DTC index
quantity, reported via Using the Jaguar Land Rover Approved
serial data, is below a Diagnostic Equipment, complete a CAN
specified range network integrity test. Refer to the
Speed control system electrical circuit diagrams and check the
fault power supply and ground connections to
Clock spring failure the speed control module. Repair wiring
harness as required
Refer to the electrical circuit diagrams
and check the clock spring wiring for
intermittent connections
Check and install a new speed control
module as required

U0405- Invalid Data Received The engine control Check speed control buttons are not
86 From Cruise Control module has jammed/contaminated/damaged
Module - Signal invalid determined failures Using the Jaguar Land Rover Approved
where some circuit Diagnostic Equipment, check speed
quantity, reported via control module for DTCs and refer to
serial data, is not the relevant DTC index
plausible given the
operating conditions
Speed control system
fault

U0415- Invalid Data Received Anti-lock brake Using the Jaguar Land Rover Approved
46 From Anti-Lock Brake system failure Diagnostic Equipment, check anti-lock
System (ABS) Control brake system control module for DTCs
Module - Calibration / and refer to the relevant DTC index
parameter memory failure
U0415- Invalid Data Received Signal error for Using the Jaguar Land Rover Approved
68 From Anti-Lock Brake vehicle speed over Diagnostic Equipment, check anti-lock
System (ABS) Control CAN brake system control module for DTCs
Module - Event Harness failure - CAN and refer to the relevant DTC index
information circuit Using the Jaguar Land Rover Approved
Diagnostic Equipment, complete a CAN
network integrity test

U0415- Invalid Data Received The engine control Using the Jaguar Land Rover Approved
85 From Anti-Lock Brake module has Diagnostic Equipment, check anti-lock
System (ABS) Control determined failures brake system control module for DTCs
Module - Signal above where some circuit and refer to the relevant DTC index
allowable range quantity, reported via
serial data, is above a
specified range
Anti-lock brake
system failure

U0422- Invalid Data Received Harness failure - CAN Using the Jaguar Land Rover Approved
87 From Body Control circuit Diagnostic Equipment carry out a
Module - Missing message Central junction box network integrity test
failure Refer to the electrical circuit diagrams
and check CAN circuits. Repair wiring
harness as required
Check the central junction box control
module for DTCs and refer to the
relevant DTC index

U0426- Invalid Data Received Immobilizer control Using the Jaguar Land Rover Approved
00 From Vehicle Immobilizer module has received Diagnostic Equipment carry out a
Control Module - No sub an invalid identity network integrity test
type information response Refer to the electrical circuit diagrams
Module substituted and check CAN circuits. Repair wiring
harness as required
Using the Jaguar Land Rover Approved
Diagnostic Equipment check and update
the car configuration file as required.
Clear the diagnostic trouble code and
retest
Ensure all modules installed in the
vehicle which store vehicle identity are
valid for this vehicle and are not
substitutes from a donor vehicle

U100C- Start/Stop System - The engine control Using the Jaguar Land Rover Approved
94 Unexpected operation module detected that Diagnostic Equipment, check engine
the component is control module for DTCs and refer to
operating in a way or the relevant DTC index
at a time that it has not Check the stop start functionality is
been commanded to working correctly
operate
Vehicle has taken too
long to start after an
eco stop event

U1A14- CAN Initialisation Failure Harness failure - CAN Using the Jaguar Land Rover Approved
00 - No sub type information circuit Diagnostic Equipment carry out a
Engine control module network integrity test
failure Refer to the electrical circuit diagrams
and check CAN circuits. Repair wiring
harness as required
Check and install a new engine control
module as required

U1A14- CAN Initialisation Failure Harness failure - CAN Using the Jaguar Land Rover Approved
49 - Internal electronic failure circuit Diagnostic Equipment carry out a
Engine control module network integrity test
failure Refer to the electrical circuit diagrams
and check CAN circuits. Repair wiring
harness as required
Check and install a new engine control
module as required

U2005- Vehicle Speed - Signal The engine control Check the anti-lock brake system
85 above allowable range module has module for related DTCs and refer to the
determined failures relevant DTC index
where some circuit Check the instrument cluster for related
quantity, reported via DTCs and refer to the relevant DTC
serial data, is above a index
specified range Using the Jaguar Land Rover Approved
This DTC is set when Diagnostic Equipment carry out a
the engine control network integrity test
module has recognised Refer to the electrical circuit diagrams
a vehicle speed signal and check CAN circuits. Repair wiring
which is above the harness as required
allowable range
Anti-lock brake
system failure

U2108- Adaptive Cruise Control - Adaptive speed Check adaptive speed control for DTCs
00 No sub type information control system fault and refer to the relevant DTC index
error indicating Using the Jaguar Land Rover Approved
adaptive speed control Diagnostic Equipment carry out a
fault flag set network integrity test
Refer to the electrical circuit diagrams
and check CAN circuits. Repair wiring
harness as required

U2108- Adaptive Cruise Control - The engine control Check adaptive speed control for DTCs
24 Signal stuck high module measures a and refer to the relevant DTC index
signal that remains Using the Jaguar Land Rover Approved
high when transitions Diagnostic Equipment carry out a
are expected network integrity test
Adaptive speed Refer to the electrical circuit diagrams
control system fault and check CAN circuits. Repair wiring
adaptive speed control harness as required
follow speed error

U2108- Adaptive Cruise Control - The engine control Check adaptive speed control for DTCs
64 Signal plausibility failure module detected and refer to the relevant DTC index
plausibility failures Using the Jaguar Land Rover Approved
Adaptive speed Diagnostic Equipment carry out a
control system fault network integrity test
adaptive speed control Refer to the electrical circuit diagrams
follow speed range and check CAN circuits. Repair wiring
error harness as required

U2108- Adaptive Cruise Control - Adaptive speed Check adaptive speed control for DTCs
68 Event information control system fault and refer to the relevant DTC index
error indicating Using the Jaguar Land Rover Approved
adaptive speed control Diagnostic Equipment carry out a
follow speed check network integrity test
when stationary Refer to the electrical circuit diagrams
and check CAN circuits. Repair wiring
harness as required

U2108- Adaptive Cruise Control - The engine control Check adaptive speed control for DTCs
86 Signal invalid module has and refer to the relevant DTC index
determined failures Using the Jaguar Land Rover Approved
where some circuit Diagnostic Equipment carry out a
quantity, reported via network integrity test
serial data, is not Refer to the electrical circuit diagrams
plausible given the and check CAN circuits. Repair wiring
operating conditions harness as required
Adaptive speed
control system fault
error when invalid
adaptive speed control
resume requests are
present
Published: 29-Dec-2017

2012.0 XF (X250), 100-00

General Information

Diagnostic Trouble Code Index - DTC: Engine


Control Module - 3.0L NA V6 - AJ63 (PCM) (G1426785)
DESCRIPTION AND OPERATION
Engine Control Module - V6 3.0L Petrol
CAUTION:

Diagnosis by substitution from a donor vehicle is NOT acceptable. Substitution of control modules does not
guarantee confirmation of a fault, and may also cause additional faults in the vehicle being tested and/or the donor
vehicle

NOTES:

If the control module or a component is suspect and the vehicle remains under manufacturer warranty, refer to
the warranty policy and procedures manual, or determine if any prior approval programme is in operation,
prior to the installation of a new module/component

Generic scan tools may not read the codes listed, or may read only 5-digit codes. Match the 5 digits from the
scan tool to the first 5 digits of the 7-digit code listed to identify the fault (the last 2 digits give extra
information read by the manufacturer-approved diagnostic system)

When performing voltage or resistance tests, always use a digital multimeter accurate to three decimal places
and with a current calibration certificate. When testing resistance, always take the resistance of the digital
multimeter leads into account

Check and rectify basic faults before beginning diagnostic routines involving pinpoint tests

Inspect connectors for signs of water ingress, and pins for damage and/or corrosion

If diagnostic trouble codes are recorded and, after performing the pinpoint tests, a fault is not present, an
intermittent concern may be the cause. Always check for loose connections and corroded terminals

Check DDW for open campaigns. Refer to the corresponding bulletins and SSM's which may be valid for the
specific customer complaint and carry out the recommendations as needed.

The table below lists all diagnostic trouble codes (DTCs) that could be logged in the engine control module 3.0L NA
V6, for additional diagnosis and testing information refer to the relevant diagnosis and testing section. For additional
information, refer to: Electronic Engine Controls - 3.0L (303-14C Electronic Engine Controls - V6 N/A 3.0L Petrol,
Diagnosis and Testing).

DTC Description Possible Causes Action


B10A2- Crash Input - No No signal Refer to the electrical circuit diagrams and
31 signal Loss of check restraints control module PWM signal
communication circuit for short, open circuit
between restraints
control module and
engine control module
B11DB- Battery Monitoring Battery monitoring Disconnect vehicle battery, re-connect after 60
01 Module - General system hardware fault seconds, clear diagnostic trouble code and
electrical failure retest. If diagnostic trouble code remains Check
and install a new battery monitoring module

B11DB- Battery Monitoring Battery monitoring If additional diagnostic trouble codes B108783,
87 Module - Missing module connector dis- B108786, B108787 are logged, suspect the rear
message connected/poor junction box. Check and Check and install a
connection new rear junction box as required, refer to the
Battery monitoring new module/component Check and installation
module to rear note at the top of the diagnostic trouble code
junction box LIN index. If additional diagnostic trouble codes
circuit - open circuit B108783, B108786, B108787 are NOT logged,
Battery monitoring check for good/clean contact at battery
module to battery monitoring module connector, refer to electrical
positive monitor circuit diagrams and check battery monitoring
circuit - open circuit module to rear junction box LIN circuit and
Battery monitoring battery monitoring module to battery positive
module/ rear junction monitor circuit for open circuit. Clear
box failure diagnostic trouble code and repeat automated
diagnostic procedure using manufacturer
approved diagnostic system. If diagnostic
trouble code remains suspect the battery
monitoring module, check and Check and
install a new battery monitoring module as
required, refer to the new module/component
Check and installation note at the top of the
diagnostic trouble code index

B1206- Crash Occurred - Engine control module Check restraints control module for related
68 Event information has detected the diagnostic trouble codes and refer to the
vehicle has crashed - relevant diagnostic trouble code index
event information
diagnostic trouble
code only

C0031- Left Front Wheel Invalid data received Check anti-lock brake system module for
00 Speed Sensor - No from anti-lock brake related diagnostic trouble codes and refer to
sub type system - left front relevant diagnostic trouble code index
information wheel speed signal

C0034- Right Front Wheel Invalid data received Check anti-lock brake system module for
00 Speed Sensor - No from anti-lock brake related diagnostic trouble codes and refer to
sub type system - right front relevant diagnostic trouble code index
information wheel speed signal

C0037- Left Rear Wheel Invalid data received Check anti-lock brake system module for
00 Speed Sensor - No from anti-lock brake related diagnostic trouble codes and refer to
sub type system - left rear relevant diagnostic trouble code index
information wheel speed signal

C003A- Right Rear Wheel Invalid data received Check anti-lock brake system module for
00 Speed Sensor - No from anti-lock brake related diagnostic trouble codes and refer to
sub type system - right rear relevant diagnostic trouble code index
information wheel speed signal
P0011- Intake (A) Variable camshaft Refer to the electrical circuit diagrams and
00 Camshaft Position timing circuit fault check variable camshaft timing circuits for
Timing - Over- Valve timing short, open circuit. Check the valve timing
Advanced (Bank 1) incorrectly set
- No sub type Timing chain has
information slipped

P0012- Intake (A) Variable camshaft Refer to the electrical circuit diagrams and
00 Camshaft Position timing circuit fault check variable camshaft timing circuits for
Timing - Over- Valve timing short, open circuit. Check the valve timing
Retarded (Bank 1) - incorrectly set
No sub type Timing chain has
information slipped

P0016- Crankshaft Position The relative positions Reset the sensor positions
00 - Camshaft Position of the crankshaft
Correlation - Bank position and camshaft
1 Sensor A - No position teeth are not
sub type correct
information Sensors
incorrectly
aligned on
rebuild

P0018- Crankshaft Position The relative positions Reset the sensor positions
00 - Camshaft Position of the crankshaft
Correlation - Bank position and camshaft
2 Sensor A - No position teeth are not
sub type correct
information Sensors
incorrectly
aligned on
rebuild

P0021- Intake (A) Variable camshaft Refer to the electrical circuit diagrams and
00 Camshaft Position timing circuit fault check variable camshaft timing circuits for
Timing - Over- Valve timing short, open circuit. Check the valve timing
Advanced (Bank 2) incorrectly set
- No sub type Timing chain has
information slipped

P0022- Intake (A) Variable camshaft Refer to the electrical circuit diagrams and
00 Camshaft Position timing circuit fault check variable camshaft timing circuits for
Timing - Over- Valve timing short, open circuit. Check the valve timing
Retarded (Bank 2) - incorrectly set
No sub type Timing chain has
information slipped

P0026- Intake Valve Variable camshaft Refer to the electrical circuit diagrams and
72 Control Solenoid timing solenoid fault check variable camshaft timing circuits for
Circuit Oil contamination short, open circuit. Check the oil condition and
Range/Performance Variable camshaft flow. Check for mechanical failure of
(Bank 1) - Actuator timing oil flow fault components
stuck open Variable camshaft
timing/Camshaft
mechanical failure
P0026- Intake Valve Variable camshaft Refer to the electrical circuit diagrams and
77 Control Solenoid timing solenoid fault check variable camshaft timing circuits for
Circuit Oil contamination short, open circuit. Check the oil condition and
Range/Performance Variable camshaft flow. Check for mechanical failure of
(Bank 1) - timing oil flow fault components
Commanded Variable camshaft
position not timing/Camshaft
reachable mechanical failure

P0028- Intake Valve Variable camshaft Refer to the electrical circuit diagrams and
72 Control Solenoid timing solenoid fault check variable camshaft timing circuits for
Circuit Oil contamination short, open circuit. Check the oil condition and
Range/Performance Variable camshaft flow. Check for mechanical failure of
(Bank 2) - Actuator timing oil flow fault components
stuck open Variable camshaft
timing/Camshaft
mechanical failure

P0028- Intake Valve Variable camshaft Refer to the electrical circuit diagrams and
77 Control Solenoid timing solenoid fault check variable camshaft timing circuits for
Circuit Oil contamination short, open circuit. Check the oil condition and
Range/Performance Variable camshaft flow. Check for mechanical failure of
(Bank 2) - timing oil flow fault components
Commanded Variable camshaft
position not timing/Camshaft
reachable mechanical failure

P0031- HO2S Heater Heated oxygen sensor Refer to the electrical circuit diagrams and
00 Control Circuit heater circuit - circuit check heated oxygen sensor heater circuits for
Low (Bank 1, fault short, open circuit. Check and install a new
Sensor 1) - No sub Heated oxygen sensor heated oxygen sensor as required
type information heater failure

P0032- HO2S Heater Heated oxygen sensor Refer to the electrical circuit diagrams and
00 Control Circuit heater circuit - circuit check heated oxygen sensor heater circuits for
High (Bank 1, fault short, open circuit. Check and install a new
Sensor 1) - No sub Heated oxygen sensor heated oxygen sensor as required
type information heater failure

P0036- HO2S Heater Catalytic converter Refer to the electrical circuit diagrams and
00 Control Circuit monitor sensor heater check catalytic converter monitor sensor heater
(Bank 1, Sensor 2) circuit - circuit fault circuits for short, open circuit. Check and install
- No sub type Catalytic converter new catalytic converter monitor sensor as
information monitor sensor heater required
failure

P0051- HO2S Heater Heated oxygen sensor Refer to the electrical circuit diagrams and
00 Control Circuit heater circuit - circuit check heated oxygen sensor heater circuits for
Low (Bank 2, fault short, open circuit. Check and install a new
Sensor 1) - No sub Heated oxygen sensor heated oxygen sensor as required
type information heater failure

P0052- HO2S Heater Heated oxygen sensor Refer to the electrical circuit diagrams and
00 Control Circuit heater circuit - circuit check heated oxygen sensor heater circuits for
High (Bank 2, fault short, open circuit. Check and install a new
Sensor 1) - No sub Heated oxygen sensor heated oxygen sensor as required
type information heater failure

P0054- HO2S Heater NOTE: To assist the diagnosis, using the manufacturer
00 Resistance (Bank 1, approved diagnostic system, check datalogger
Sensor 2) - No sub - Circuit HTR_HEGO_A - signal oxygen sensor (O2S) heater duty cycle
type information bank 1 sensor 1 (0x03A1)
Catalytic converter Refer to the electrical circuit diagrams and
monitor sensor heater check the catalytic converter monitor sensor
circuit, short circuit to heater circuits for short circuit to ground, short
ground, short circuit to circuit to power, open circuit, high resistance.
power, open circuit, Repair the circuit as required, clear the DTC
high resistance and retest the system
Catalytic converter If the fault persists, check and install a new
monitor sensor heater catalytic converter monitor sensor as required.
failure Refer to the warranty policy and procedures
manual, or determine if any prior approval
programme is in operation, prior to the
installation of a new module/component

P0056- HO2S Heater Catalytic converter Refer to the electrical circuit diagrams and
00 Control Circuit monitor sensor heater check catalytic converter monitor sensor heater
(Bank 2, Sensor 2) circuit - circuit fault circuits for short, open circuit. Check and install
- No sub type Catalytic converter new catalytic converter monitor sensor as
information monitor sensor heater required
failure

P0060- HO2S Heater NOTE: To assist the diagnosis, using the manufacturer
00 Resistance (Bank 2, approved diagnostic system, check datalogger
Sensor 2) - No sub - Circuit HTR_HEGO_B - signal oxygen sensor (O2S) heater duty cycle
type information bank 2 sensor 2 (0x03A5)
Catalytic converter Refer to the electrical circuit diagrams and
monitor sensor heater check the catalytic converter monitor sensor
circuit, short circuit to heater circuits for short circuit to ground, short
ground, short circuit to circuit to power, open circuit, high resistance.
power, open circuit, Repair the circuit as required, clear the DTC
high resistance and retest the system
Catalytic converter If the fault persists, check and install a new
monitor sensor heater catalytic converter monitor sensor as required.
failure Refer to the warranty policy and procedures
manual, or determine if any prior approval
programme is in operation, prior to the
installation of a new module/component

P0069- MAP - Barometric Manifold absolute Check for manifold absolute pressure sensor
00 Pressure pressure sensor failure related diagnostic trouble codes and refer to the
Correlation - No BARO sensor failure diagnostic trouble code index in this section.
sub type (internal engine Check and install a new engine control module.
information control module fault) Refer to new module/component Check and
installation Note at top of diagnostic trouble
code index

P0071- Ambient Air Ambient temperature Refer to the electrical circuit diagrams and
00 Temperature value missing from check ambient air temperature sensor circuits
Sensor CAN bus for short to ground, power, open circuit. Check
Range/Performance and Check and install a new sensor as required
- No sub type
information
P0072- Ambient Air Ambient air Refer to the electrical circuit diagrams and
00 Temperature temperature sensor check ambient air temperature sensor circuits
Sensor Circuit Low circuit - short to for short to ground, high resistance
- No sub type ground, high resistance
information
P0073- Ambient Air Ambient air Refer to the electrical circuit diagrams and
00 Temperature temperature sensor check ambient air temperature sensor circuits
Sensor Circuit High circuit - short to power for short to power
- No sub type
information
P0075- Intake Valve Variable camshaft Refer to the electrical circuit diagrams and
14 Control Circuit timing control check variable camshaft timing control solenoid
(Bank 1) - Circuit solenoid circuit - short circuit for short to ground, open circuit
short to ground or to ground, open circuit
open
P0077- Intake Valve Variable camshaft Refer to the electrical circuit diagrams and
00 Control Circuit timing control check variable camshaft timing circuits for
High (Bank 1) - No solenoid circuit - short short to power. Check and install a new variable
sub type to power camshaft timing control solenoid as required
information Variable camshaft
timing solenoid failure

P0081- Intake Valve Variable camshaft Refer to the electrical circuit diagrams and
14 Control Circuit timing control check variable camshaft timing control solenoid
High (Bank 2) - solenoid circuit - short circuit for short to ground, open circuit
Circuit short to to ground, open circuit
ground or open
P0083- Intake Valve Variable camshaft Refer to the electrical circuit diagrams and
00 Control Circuit timing control check variable camshaft timing circuits for
High (Bank 2) - No solenoid circuit - short short to power. Check and install a new variable
sub type to power camshaft timing control solenoid as required
information Variable camshaft
timing solenoid failure

P0087- Fuel Rail/System Fuel rail pressure (Fuel Refer to the electrical circuit diagrams and
00 Pressure - Too Low rail pressure) sensor, check fuel rail pressure sensor circuits for short
- No sub type sensing circuit - short to ground, open circuit, high resistance. Check
information to ground, open circuit and install a new fuel rail pressure sensor as
Fuel rail pressure required. Check fuel system for failure
sensor supply circuit -
high resistance
Fuel rail pressure
sensor failure
Fuel pump failure
Fuel line leak,
restriction

P0088- Fuel Rail/System Fuel rail pressure Refer to the electrical circuit diagrams and
00 Pressure - Too sensor supply/sensing check fuel rail pressure sensor circuits for short
High - No sub type circuits - short to each to each other, power, open circuit, high
information other resistance. Check and install a new fuel rail
Fuel rail pressure pressure sensor as required. Check fuel system
sensor sensing circuit - for failure
short to power
Fuel rail pressure
sensor ground circuit -
high resistance
Fuel rail pressure
sensor failure
Restricted fuel line
Fuel pump short
circuit to power

P0101- Mass or Volume Blocked air cleaner Check air cleaner element is free from
00 Air Flow A Circuit element restriction. Check for leak from air intake
Range/Performance Leakage from air system, rectify as required. Ensure the engine
- No sub type intake system breather system is correctly installed and in
information Engine breather leak serviceable condition. Refer to the electrical
Mass air flow sensor circuit diagrams and check mass air flow sensor
sensing circuit - high circuit for intermittent short to ground, high
resistance, intermittent resistance. Check and install a new mass air
short to ground flow sensor as required
Mass air flow sensor
supply circuit - high
resistance
Mass air flow sensor
failure

P0102- Mass or Volume Mass air flow sensor Refer to the electrical circuit diagrams and
00 Air Flow A Circuit circuits - short to check mass air flow sensor circuits for short to
Low - No sub type ground, high resistance power ground, high resistance. Check and
information Mass air flow sensor install a new mass air flow sensor as required
ground circuit - high
resistance
Mass air flow sensor
failure

P0103- Mass or Volume Mass air flow sensor Refer to the electrical circuit diagrams and
00 Air Flow A Circuit circuits - short to check mass air flow sensor circuits for short to
High - No sub type power power, ground, high resistance. Check and
information Mass air flow sensor install a new mass air flow sensor as required
ground circuit - high
resistance
Mass air flow sensor
failure

P0106- Manifold Absolute Intake manifold air Check for correct installation and serviceability
00 Pressure/BARO leak (loose or missing of intake manifold and associated components.
Sensor component) Refer to the electrical circuit diagrams and
Range/Performance Manifold absolute check manifold absolute pressure sensor circuits
- No sub type pressure sensor signal for short, open circuit. Check and install a new
information circuit fault manifold absolute pressure sensor as required
Manifold absolute
pressure sensor failure

P0107- Manifold Absolute Manifold absolute Refer to the electrical circuit diagrams and
00 Pressure/BARO pressure sensor check manifold absolute pressure sensor circuits
Sensor Low - No circuits - short to for short to ground, high resistance. Check and
sub type ground, high resistance install a new manifold absolute pressure sensor
information Manifold absolute as required
pressure sensor ground
circuits - high
resistance
Manifold absolute
pressure sensor failure

P0108- Manifold Absolute Manifold absolute Refer to the electrical circuit diagrams and
00 Pressure/BARO pressure sensor check manifold absolute pressure sensor circuits
Sensor High - No circuits - short to for short to power, high resistance. Check and
sub type power install a new manifold absolute pressure sensor
information Manifold absolute as required
pressure sensor power
circuits - high
resistance
Manifold absolute
pressure sensor failure

P0111- Intake Air Intake air temperature Refer to the electrical circuit diagrams and
23 Temperature sensor sensing circuit - check intake air temperature sensor circuits for
Sensor 1 Circuit high resistance short, open circuit, high resistance. Check and
Range/Performance Intake air temperature install a new mass air flow sensor as required
- Signal stuck low sensor failure

P0111- Intake Air Intake air temperature Refer to the electrical circuit diagrams and
24 Temperature sensor sensing circuit - check intake air temperature sensor circuits for
Sensor 1 Circuit high resistance short, open circuit, high resistance. Check and
Range/Performance Intake air temperature install a new mass air flow sensor as required
- Signal stuck high sensor failure

P0111- Intake Air Intake air temperature Refer to the electrical circuit diagrams and
29 Temperature sensor sensing circuit - check intake air temperature sensor circuits for
Sensor 1 Circuit high resistance short, open circuit, high resistance. Check and
Range/Performance Intake air temperature install a new mass air flow sensor as required
- Signal invalid sensor failure

P0112- Intake Air Intake air temperature Refer to the electrical circuit diagrams and
00 Temperature sensor sensing circuit - check intake air temperature sensor circuits for
Sensor 1 Circuit high resistance, short, open circuit, high resistance,
Low - No sub type disconnected disconnected connector. Check and install a
information Intake air temperature new mass air flow sensor as required
sensor failure

P0113- Intake Air Intake air temperature Refer to the electrical circuit diagrams and
00 Temperature sensor sensing circuit - check intake air temperature sensor circuits for
Sensor 1 Circuit short to ground, short short, open circuit, high resistance. Check and
High - No sub type to power install a new mass air flow sensor as required
information Intake air temperature
sensor failure

P0116- Engine Coolant Low coolant level Fill cooling system to correct level and
23 Temperature Engine coolant specification. Refer to the electrical circuit
Sensor 1 Circuit temperature sensor diagrams and check engine coolant temperature
Range/Performance sensing circuit - sensor circuits for intermittent high resistance.
- Signal stuck low intermittent high Check and install new engine thermostat as
resistance required. Check and install a new engine
Engine thermostat coolant temperature sensor as required
failure
Engine coolant
temperature sensor
failure

P0116- Engine Coolant Low coolant level Fill cooling system to correct level and
24 Temperature Engine coolant specification. Refer to the electrical circuit
Sensor 1 Circuit temperature sensor diagrams and check engine coolant temperature
Range/Performance sensing circuit - sensor circuits for intermittent high resistance.
- Signal stuck high intermittent high Check and install new engine thermostat as
resistance required. Check and install a new engine
Engine thermostat coolant temperature sensor as required
failure
Engine coolant
temperature sensor
failure

P0116- Engine Coolant Low coolant level Fill cooling system to correct level and
29 Temperature Engine coolant specification. Refer to the electrical circuit
Sensor 1 Circuit temperature sensor diagrams and check engine coolant temperature
Range/Performance sensing circuit - sensor circuits for intermittent high resistance.
- Signal invalid intermittent high Check and install new engine thermostat as
resistance required. Check and install a new engine
Engine thermostat coolant temperature sensor as required
failure
Engine coolant
temperature sensor
failure

P0117- Engine Coolant Engine coolant Refer to the electrical circuit diagrams and
00 Temperature temperature sensor check engine coolant temperature sensor
Sensor 1 Circuit sensing circuit - short circuits for short to power, high resistance, open
Low - No sub type to power, high circuit, disconnected connector. Check and
information resistance, open install a new engine coolant temperature sensor
circuit, disconnected as required
Engine coolant
temperature sensor
failure

P0118- Engine Coolant Engine overheat Check for cooling fan circuit diagnostic trouble
00 Temperature condition/cooling fan codes and refer to relevant action specified in
Sensor 1 Circuit failure diagnostic trouble code index. Refer to the
High - No sub type Engine coolant electrical circuit diagrams and check engine
information temperature sensor coolant temperature sensor circuits for short to
sensing circuit - short ground. Check and install a new engine coolant
to ground temperature sensor as required
Engine coolant
temperature sensor
failure

P0121- Throttle/Pedal Electrical Cause Vehicle Conditions to enable DTC Logging


00 Position Sensor A Yes strategy
Circuit Mechanical Cause Ignition On, Engine greater than 1200rpm
Range/Performance No for 5 seconds
- No sub type Control Module Prioritised Checks to Perform
information Cavity Diagnosis of this DTC may require using the
Potentiometer 1 manufacturer approved diagnostic system check
Potentiometer 2 datalogger signals
Monitor Description 0xF447 Absolute throttle position B
Difference 0xF411 Absolute throttle position
between Using the manufacturer approved diagnostic
electronic system, with ignition on but engine off, check
throttle position electric throttle position potentiometer signal 1
potentiometer is aligned to electric throttle position
signals from potentiometer signal 2
sensor 1 and Refer to the electrical circuit diagrams and
sensor 2 check electric throttle position signal
Prioritised List of potentiometer 1 circuit for short circuit to
Possible Causes power, short circuit to ground or high resistance
Electric throttle Inspect electric throttle connector and
position signal powertrain control module connector for signs
potentiometer 1 of water ingress, and pins for damage and/or
circuit, short circuit to corrosion
power, short circuit to Install a new electric throttle unit, only when
ground or high diagnosed as failed
resistance Install a new powertrain control module, only
Harness failure - when diagnosed as failed
Electric throttle Using the Jaguar Land Rover approved
position signal diagnostic equipment, clear the DTC and retest
potentiometer 1 circuit
Electric throttle unit
failure
Powertrain control
module failure

P0122- Throttle/Pedal Electrical Cause Vehicle Conditions to enable DTC Logging


00 Position Sensor A Yes strategy
Circuit Low - No Mechanical Cause During throttle adaption process at
sub type No ignition ON engine OFF the amplifier is
information Control Module checked
Cavity Prioritised Checks to Perform
Potentiometer 1 Refer to the electrical circuit diagrams and
Monitor Description check electric throttle position signal
Amplified signal potentiometer 1 circuit for open circuit, short
is out of range circuit to ground
of expected 4 x Inspect electric throttle connector and
amplification powertrain control module connector for signs
from raw TPS1 of water ingress, and pins for damage and/or
input signal corrosion
Prioritised List of Install a new electric throttle unit, only when
Possible Causes diagnosed as failed
Electric throttle Install a new powertrain control module, only
position signal when diagnosed as failed
potentiometer 1 Using the Jaguar Land Rover approved
circuit, open circuit, diagnostic equipment, clear the DTC and retest
short circuit to ground
Harness failure -
Electric throttle
position signal
potentiometer 1 circuit
Electric throttle unit
failure
Powertrain control
module failure

P0123- Throttle/Pedal Throttle position Refer to the electrical circuit diagrams and
00 Position Sensor A sensor sensing circuit check throttle position sensor sensing circuit TP
Circuit High - No TP 1 - short to power 1 for short to power. Check and install a new
sub type Throttle position throttle body as required
information sensor failure

P0125- Insufficient Low coolant level Fill cooling system to correct level and
00 Coolant Temp For Engine coolant specification. Refer to the electrical circuit
Closed Loop Fuel temperature sensor diagrams and check engine coolant temperature
Control - No sub sensing circuit - sensor sensing circuit for intermittent high
type information intermittent high resistance. Check and install new engine
resistance thermostat as required. Check and install a new
Engine thermostat engine coolant temperature sensor as required
failure
Engine coolant
temperature sensor
failure

P0131- O2 Circuit Low Exhaust gas leakage Check for and rectify any exhaust leak between
1A Voltage (Bank 1, Heated oxygen sensor cylinder head and catalytic converter (e.g.
Sensor 1) - Circuit variable/constant manifolds, exhaust gas recirculation system
resistance below circuit - circuit fault, etc.). Refer to the electrical circuit diagrams and
threshold disconnected check heated oxygen sensor variable/constant
Heated oxygen sensor circuit for short, open circuit, disconnected
failure connector. Check and install a new heated
oxygen sensor as required

P0132- O2 Circuit High Exhaust gas leakage Check for and rectify any exhaust leak between
1B Voltage (Bank 1, Heated oxygen sensor cylinder head and catalytic converter (e.g.
Sensor 1) - Circuit variable/constant manifolds, exhaust gas recirculation system
resistance above circuit - circuit fault, etc.). Refer to the electrical circuit diagrams and
threshold disconnected check heated oxygen sensor variable/constant
Heated oxygen sensor circuit for short, open circuit, disconnected
failure connector. Check and install a new heated
oxygen sensor as required

P0133- O2 Circuit Slow Exhaust leak Check for and rectify any exhaust leak between
00 Response (Bank 1, Heated oxygen sensor cylinder head and catalytic converter (e.g.
Sensor 1) - No sub to engine control manifolds, exhaust gas recirculation system
type information module wiring shield etc.). Refer to the electrical circuit diagrams and
high resistance check heated oxygen sensor to engine control
Fuel control system module wiring shield for high resistance. Check
fault fuel control system for failure. Check and
Heated oxygen sensor install a new heated oxygen sensor as required
failure

P0134- O2 Circuit No Catalytic converter Refer to the electrical circuit diagrams and
00 Activity Detected monitor sensing circuit check catalytic converter monitor sensor
(Bank 1, Sensor 1) - short to ground, short circuits for short to ground, power, high
- No sub type to power, high resistance, disconnected connector and ground
information resistance, braided shield for high resistance. Check and
disconnected install new catalytic converter monitor sensor as
Catalytic converter required
monitor sensor ground
braided shield - high
resistance
Catalytic converter
monitor sensor -
mechanical damage

P0137- O2 Circuit Low Catalytic converter Refer to the electrical circuit diagrams and
00 Voltage (Bank 1, monitor sensor sensing check catalytic converter monitor sensor
Sensor 2) - No sub circuit - short to sensing circuit for short to ground, high
type information ground, high resistance, disconnected connector. Check and
resistance, install new catalytic converter monitor sensor as
disconnected required
Catalytic converter
monitor sensor failure

P0138- O2 Circuit High Catalytic converter Refer to the electrical circuit diagrams and
00 Voltage (Bank 1, monitor sensor sensing check catalytic converter monitor sensor
Sensor 2) - No sub circuit - short to power circuits for short to power, and ground braided
type information Catalytic converter shield for high resistance. Check and install
monitor sensor ground new catalytic converter monitor sensor as
braided shield - high required
resistance
Catalytic converter
monitor sensor failure

P0140- O2 Circuit No Catalytic converter Refer to the electrical circuit diagrams and
00 Activity Detected monitor sensing circuit check catalytic converter monitor sensor
(Bank 1, Sensor 2) - short to ground, short circuits for short to ground, power, high
- No sub type to power, high resistance, disconnected connector and ground
information resistance, braided shield for high resistance. Check and
disconnected install new catalytic converter monitor sensor as
Catalytic converter required
monitor sensor ground
braided shield - high
resistance
Catalytic converter
monitor sensor -
mechanical damage

P0141- O2 Heater Circuit Catalytic converter Refer to the electrical circuit diagrams and
00 (Bank 1, Sensor 2) monitor sensor heater check catalytic converter monitor sensor heater
- No sub type control circuit - high control circuit for high resistance. Check and
information resistance install a new catalytic converter monitor sensor
Catalytic converter as required
monitor sensor heater
failure

P0151- O2 Circuit Low Heated oxygen sensor Refer to the electrical circuit diagrams and
1A Voltage (Bank 2, sensing circuit - short check heated oxygen sensor sensing circuit for
Sensor 1) - Circuit to ground, short to short to ground, power, high resistance. Check
resistance below power, high resistance and install a new heated oxygen sensor as
threshold Heated oxygen sensor required
failure

P0152- O2 Circuit High Heated oxygen sensor Refer to the electrical circuit diagrams and
1B Voltage (Bank 2, sensing circuit - short check heated oxygen sensor sensing circuit for
Sensor 1) - Circuit to ground, short to short to ground, power, high resistance. Check
resistance above power, high resistance and install a new heated oxygen sensor as
threshold Heated oxygen sensor required
failure

P0153- O2 Circuit Slow Heated oxygen sensor Refer to the electrical circuit diagrams and
00 Response (Bank 2, to engine control check heated oxygen sensor to engine control
Sensor 1) - No sub module wiring shield module wiring shield for high resistance. Check
type information high resistance for and rectify any exhaust leak between
Exhaust leak cylinder head and catalytic converter (e.g.
Fuel control system manifolds, exhaust gas recirculation system
fault etc.). Check fuel control system for failure.
Heated oxygen sensor Check and install a new heated oxygen sensor
failure as required

P0154- O2 Circuit No Catalytic converter Refer to the electrical circuit diagrams and
00 Activity Detected monitor sensing circuit check catalytic converter monitor sensor
(Bank 2, Sensor 1) - short to ground, short circuits for short to ground, power, high
- No sub type to power, high resistance, disconnected connector and ground
information resistance, braided shield for high resistance. Check and
disconnected install new catalytic converter monitor sensor as
Catalytic converter required
monitor sensor ground
braided shield - high
resistance
Catalytic converter
monitor sensor -
mechanical damage

P0157- O2 Circuit Low Catalytic converter Refer to the electrical circuit diagrams and
00 Voltage (Bank 2, monitor sensor sensing check catalytic converter monitor sensor
Sensor 2) - No sub circuit - short to sensing circuit for short to ground, high
type information ground, high resistance, disconnected connector. Check and
resistance, install a new catalytic converter monitor sensor
disconnected as required
Catalytic converter
monitor sensor failure

P0158- O2 Circuit High Catalytic converter Refer to the electrical circuit diagrams and
00 Voltage (Bank 2, monitor sensor sensing check catalytic converter monitor sensor
Sensor 2) - No sub circuit - short to power sensing circuit for short to power, and sensor
type information Catalytic converter ground braided shield for high resistance.
monitor sensor ground Check and install a new catalytic converter
braided shield - high monitor sensor as required
resistance
Catalytic converter
monitor sensor failure

P0159- O2 Circuit Slow Catalytic converter Check catalytic converter monitor sensor tip for
00 Response (Bank 2, monitor sensor tip damage or blockage, install a new sensor as
Sensor 2) - No sub damaged or blocked required
type information
P0160- O2 Circuit No Catalytic converter Refer to the electrical circuit diagrams and
00 Activity Detected monitor sensing circuit check catalytic converter monitor sensing
(Bank 2, Sensor 2) - short to ground, short circuit for short to ground, short to power, high
- No sub type to power, high resistance, disconnected connector, and sensor
information resistance, ground braided shield for high resistance.
disconnected Check and install a new catalytic converter
Catalytic converter monitor sensor as required
monitor sensor ground
braided shield - high
resistance
Catalytic converter
monitor sensor -
mechanical damage

P0161- O2 Heater Circuit Catalytic converter Refer to the electrical circuit diagrams and
00 (Bank 2, Sensor 2) monitor sensor heater check catalytic converter monitor sensor heater
- No sub type control circuit control circuit for short, open circuit
information malfunction

P0171- System too lean Air intake leak Check for leak from air intake system. Check
00 (bank 1) - No sub between mass air flow for fuel system blockage/restriction. Check for
type information sensor and cylinder additional mass air flow sensor related
head diagnostic trouble codes and refer to relevant
Fuel filter, injector, diagnostic trouble code index. Check and
system restriction rectify any exhaust leak prior to catalytic
Mass air flow sensor converter
fault (low intake air
flow)
Exhaust leak (forward
of catalytic converter)

P0172- System Too Rich Restricted air cleaner Check air cleaner element is free from
00 (Bank 1) - No sub Leaking fuel restriction. Check for leaking injectors, install
type information injector(s) new injector(s) as required. Check for
Engine oil contaminated engine oil, drain and refill engine
contaminated with fuel oil as required. Check for additional mass air
(too many cold starts flow sensor related diagnostic trouble codes and
with vehicle refer to relevant diagnostic trouble code index
subsequently not
getting hot enough for
long enough)
Mass air flow sensor
fault (high intake air
flow)

P0174- System Too Lean Air intake leak Check for leak from air intake system. Check
00 (Bank 2) - No sub between mass air flow for fuel system blockage/restriction. Check for
type information sensor and cylinder additional mass air flow sensor related
head diagnostic trouble codes and refer to relevant
Fuel filter, injector, diagnostic trouble code index. Check and
system restriction rectify any exhaust leak prior to catalytic
Mass air flow sensor converter
fault (low intake air
flow)
Exhaust leak (forward
of catalytic converter)

P0175- System Too Rich Restricted air cleaner Check air cleaner element is free from
00 (Bank 2) - No sub Leaking fuel restriction. Check for leaking injectors, install
type information injector(s) new injector(s) as required. Check for
Engine oil contaminated engine oil, drain and refill engine
contaminated with fuel oil as required. Check for additional mass air
(too many cold starts flow sensor related diagnostic trouble codes and
with vehicle refer to relevant diagnostic trouble code index
subsequently not
getting hot enough for
long enough)
Mass air flow sensor
fault (high intake air
flow)

P0181- Fuel Temperature Fuel temperature Refer to the electrical circuit diagrams and
23 Sensor A Circuit sensor sensing circuit - check fuel temperature sensor circuits for short
Range/Performance short to ground, short to ground, power, high resistance. Check and
- Signal stuck low to power, high install a new Fuel temperature sensor as
resistance required
Fuel temperature
sensor ground circuit -
high resistance
Fuel temperature
sensor failure

P0181- Fuel Temperature Fuel temperature Refer to the electrical circuit diagrams and
24 Sensor A Circuit sensor sensing circuit - check fuel temperature sensor circuits for short
Range/Performance short to ground, short to ground, power, high resistance. Check and
- Signal stuck high to power, high install a new Fuel temperature sensor as
resistance required
Fuel temperature
sensor ground circuit -
high resistance
Fuel temperature
sensor failure

P0181- Fuel Temperature Fuel temperature Refer to the electrical circuit diagrams and
29 Sensor A Circuit sensor sensing circuit - check fuel temperature sensor circuits for short
Range/Performance short to ground, short to ground, power, high resistance. Check and
- Signal invalid to power, high install a new Fuel temperature sensor as
resistance required
Fuel temperature
sensor ground circuit -
high resistance
Fuel temperature
sensor failure

P0182- Fuel Temperature Fuel temperature Refer to the electrical circuit diagrams and
00 Sensor A Circuit sensor sensing circuit - check fuel temperature sensor circuits for short
Low - No sub type short to ground to ground, power, high resistance. Check and
information Fuel temperature install a new Fuel temperature sensor as
sensor ground circuit - required
short circuit
Fuel temperature
sensor failure

P0183- Fuel Temperature Fuel temperature Refer to the electrical circuit diagrams and
00 Sensor A Circuit sensor sensing circuit - check fuel temperature sensor circuits for short
High - No sub type short to power, high to ground, power, high resistance. Check and
information resistance, install a new Fuel temperature sensor as
disconnected required
Fuel temperature
sensor ground circuit -
high resistance
Fuel temperature
sensor failure

P0191- Fuel Rail Pressure Fuel rail pressure To assist the diagnosis using the manufacturer
00 Sensor A Circuit sensor stuck approved diagnostic system check datalogger
Range/Performance signal Fuel Rail Pressure Sensor - High Range
- No sub type Sensor Voltage (0x0377)
information Refer to the electrical circuit diagrams and
check fuel rail pressure sensor A circuit for
short to power, short to ground, high resistance,
open circuit, terminal damage or corrosion
Check and install a new fuel rail pressure sensor
A as required

P0192- Fuel Rail Pressure Fuel rail pressure Refer to the electrical circuit diagrams and
00 Sensor A Circuit sensor sensing circuit - check fuel rail pressure sensor circuits for short
Low - No sub type short to ground, high to ground, power, high resistance, disconnected
information resistance, connector. Check and install a new fuel rail
disconnected pressure sensor as required
Fuel rail pressure
sensor 5V supply
circuit - high
resistance
Fuel rail pressure
sensor failure

P0193- Fuel Rail Pressure Fuel rail pressure Refer to the electrical circuit diagrams and
00 Sensor A Circuit sensor supply/sensing check fuel rail pressure sensor circuits for short
High - No sub type circuits - short circuit to ground, power, high resistance, disconnected
information to each other connector. Check and install a new fuel rail
Fuel rail pressure pressure sensor as required
sensor sensing circuit -
short to power
Fuel rail pressure
sensor ground circuit -
high resistance
Fuel rail pressure
sensor failure

P0196- Engine Oil Engine oil temperature Refer to the electrical circuit diagrams and
23 Temperature sensor sensing circuit - check engine oil temperature sensor circuits for
Sensor Circuit intermittent high short to ground, power, high resistance. Check
Range/Performance resistance and install a new engine oil temperature sensor
- Signal stuck low Engine oil temperature as required
sensor failure

P0196- Engine Oil Engine oil temperature Refer to the electrical circuit diagrams and
24 Temperature sensor sensing circuit - check engine oil temperature sensor circuits for
Sensor Circuit intermittent high short to ground, power, high resistance. Check
Range/Performance resistance and install a new engine oil temperature sensor
- Signal stuck high Engine oil temperature as required
sensor failure

P0196- Engine Oil Engine oil temperature Refer to the electrical circuit diagrams and
29 Temperature sensor sensing circuit - check engine oil temperature sensor circuits for
Sensor Circuit intermittent high short to ground, power, high resistance. Check
Range/Performance resistance and install a new engine oil temperature sensor
- Signal invalid Engine oil temperature as required
sensor failure

P0197- Engine Oil Engine oil temperature Refer to the electrical circuit diagrams and
00 Temperature sensor sensing circuit - check engine oil temperature sensor circuits for
Sensor Circuit Low short to ground short to ground, power, high resistance. Check
- No sub type Engine oil temperature and install a new engine oil temperature sensor
information sensor failure as required

P0198- Engine Oil Engine oil temperature Refer to the electrical circuit diagrams and
00 Temperature sensor sensing circuit - check engine oil temperature sensor circuits for
Sensor Circuit High short to power, high short to ground, power, high resistance,
- No sub type resistance, disconnected connector. Check and install a
information disconnected new engine oil temperature sensor as required
Engine oil temperature
sensor failure

P0201- Cylinder 1 Injector Injector circuit - short Refer to the electrical circuit diagrams and
00 Circuit / Open - No to ground, high check injector circuits for short to ground, high
sub type resistance, resistance, disconnected connector. Check and
information disconnected install a new injector as required
Injector failure

P0202- Cylinder 2 Injector Injector circuit - short Refer to the electrical circuit diagrams and
00 Circuit / Open - No to ground, high check injector circuits for short to ground, high
sub type resistance, resistance, disconnected connector. Check and
information disconnected install a new injector as required
Injector failure

P0203- Cylinder 3 Injector Injector circuit - short Refer to the electrical circuit diagrams and
00 Circuit / Open - No to ground, high check injector circuits for short to ground, high
sub type resistance, resistance, disconnected connector. Check and
information disconnected install a new injector as required
Injector failure

P0204- Cylinder 4 Injector Injector circuit - short Refer to the electrical circuit diagrams and
00 Circuit / Open - No to ground, high check injector circuits for short to ground, high
sub type resistance, resistance, disconnected connector. Check and
information disconnected install a new injector as required
Injector failure

P0205- Cylinder 5 Injector Injector circuit - short Refer to the electrical circuit diagrams and
00 Circuit / Open - No to ground, high check injector circuits for short to ground, high
sub type resistance, resistance, disconnected connector. Check and
information disconnected install a new injector as required
Injector failure

P0206- Cylinder 6 Injector Injector circuit - short Refer to the electrical circuit diagrams and
00 Circuit / Open - No to ground, high check injector circuits for short to ground, high
sub type resistance, resistance, disconnected connector. Check and
information disconnected install a new injector as required
Injector failure

P0222- Throttle/Pedal Electrical Cause Vehicle Conditions to enable DTC Logging


00 Position Yes strategy
Sensor/Switch B Mechanical Cause During throttle adaption process at
Circuit Low - No No ignition ON engine OFF the amplifier is
sub type Control Module checked
information Cavity Prioritised Checks to Perform
Potentiometer 2 Refer to the electrical circuit diagrams and
Monitor Description check electric throttle position signal
Amplified signal potentiometer 2 circuit for open circuit, short
is out of range circuit to ground
of expected 4 x Inspect electric throttle connector and
amplification powertrain control module connector for signs
from raw TPS2 of water ingress, and pins for damage and/or
input signal corrosion
Prioritised List of Install a new electric throttle unit, only when
Possible Causes diagnosed as failed
Electric throttle Install a new powertrain control module, only
position signal when diagnosed as failed
potentiometer 2 Using the Jaguar Land Rover approved
circuit, open circuit, diagnostic equipment, clear the DTC and retest
short circuit to ground
Harness failure -
Electric throttle
position signal
potentiometer 2 circuit
Electric throttle unit
failure
Powertrain control
module failure

P0223- Throttle/Pedal Throttle position Refer to the electrical circuit diagrams and
00 Position sensor sensing circuit check throttle position sensor sensing circuit TP
Sensor/Switch B TP 2- short to power 2 for short to power. Check and install a new
Circuit High - No Throttle position throttle body as required
sub type sensor failure
information
P0227- Throttle/Pedal Accelerator pedal Refer to the electrical circuit diagrams and
00 Position position sensor circuit check accelerator pedal position sensor circuit
Sensor/Switch C APP 1 - short to APP 1 for short to ground, high resistance
Circuit Low - No ground, high resistance
sub type
information
P0228- Throttle/Pedal Accelerator pedal Refer to the electrical circuit diagrams and
00 Position position sensor circuit check accelerator pedal position sensor circuit
Sensor/Switch C APP 1 - short to power APP 1 for short to power
Circuit High - No
sub type
information
P0231- Fuel Pump Fuel pump driver Refer to the electrical circuit diagrams and
00 Secondary Circuit module signal circuit check fuel pump driver module monitor circuit
Low - No sub type short to ground, open to engine control module for short to ground,
information circuit high resistance

P0232- Fuel Pump Fuel pump driver Refer to the electrical circuit diagrams and
00 Secondary Circuit module signal circuit check fuel pump driver module monitor circuit
High - No sub type short to power to engine control module for short to power
information
P0300- Random Misfire Poor fuel quality Check engine control module for related misfire
00 Detected - No sub Catalyst/exhaust diagnostic trouble codes and refer to this
type information system blockage diagnostic trouble code index
Spark plug(s) fouled or Check the fuel system for blockages, repair as
failed required
Injector(s) circuit short Check the catalyst/exhaust system for blockage,
to ground, short to repair as required
power, open circuit Check and install a new spark plug(s) as
Injector(s) failure required
Fuel system Refer to the electrical circuit diagrams and
excessively too lean or check injector(s) circuit for short to ground,
too rich power, open circuit
Camshaft position Check and install a new injector(s) as required
sensor failure Check for air leaks within the intake system
Check and install a new camshaft position
sensor as required

P0301- Cylinder 1 Misfire Poor fuel quality Check engine control module for related misfire
00 Detected - No sub Catalyst/exhaust diagnostic trouble codes and refer to this
type information system blockage diagnostic trouble code index
Spark plug(s) fouled or Check the fuel system for blockages, repair as
failed required
Injector(s) circuit short Check the catalyst/exhaust system for blockage,
to ground, short to repair as required
power, open circuit Check and install a new spark plug(s) as
Injector(s) failure required
Fuel system Refer to the electrical circuit diagrams and
excessively too lean or check injector(s) circuit for short to ground,
too rich power, open circuit
Camshaft position Check and install a new injector(s) as required
sensor failure Check for air leaks within the intake system
Check and install a new camshaft position
sensor as required

P0302- Cylinder 2 Misfire Poor fuel quality Check engine control module for related misfire
00 Detected - No sub Catalyst/exhaust diagnostic trouble codes and refer to this
type information system blockage diagnostic trouble code index
Spark plug(s) fouled or Check the fuel system for blockages, repair as
failed required
Injector(s) circuit short Check the catalyst/exhaust system for blockage,
to ground, short to repair as required
power, open circuit Check and install a new spark plug(s) as
Injector(s) failure required
Fuel system Refer to the electrical circuit diagrams and
excessively too lean or check injector(s) circuit for short to ground,
too rich power, open circuit
Camshaft position Check and install a new injector(s) as required
sensor failure Check for air leaks within the intake system
Check and install a new camshaft position
sensor as required
P0303- Cylinder 3 Misfire Poor fuel quality Check engine control module for related misfire
00 Detected - No sub Catalyst/exhaust diagnostic trouble codes and refer to this
type information system blockage diagnostic trouble code index
Spark plug(s) fouled or Check the fuel system for blockages, repair as
failed required
Injector(s) circuit short Check the catalyst/exhaust system for blockage,
to ground, short to repair as required
power, open circuit Check and install a new spark plug(s) as
Injector(s) failure required
Fuel system Refer to the electrical circuit diagrams and
excessively too lean or check injector(s) circuit for short to ground,
too rich power, open circuit
Camshaft position Check and install a new injector(s) as required
sensor failure Check for air leaks within the intake system
Check and install a new camshaft position
sensor as required

P0304- Cylinder 4 Misfire Poor fuel quality Check engine control module for related misfire
00 Detected - No sub Catalyst/exhaust diagnostic trouble codes and refer to this
type information system blockage diagnostic trouble code index
Spark plug(s) fouled or Check the fuel system for blockages, repair as
failed required
Injector(s) circuit short Check the catalyst/exhaust system for blockage,
to ground, short to repair as required
power, open circuit Check and install a new spark plug(s) as
Injector(s) failure required
Fuel system Refer to the electrical circuit diagrams and
excessively too lean or check injector(s) circuit for short to ground,
too rich power, open circuit
Camshaft position Check and install a new injector(s) as required
sensor failure Check for air leaks within the intake system
Check and install a new camshaft position
sensor as required

P0305- Cylinder 5 Misfire Poor fuel quality Check engine control module for related misfire
00 Detected - No sub Catalyst/exhaust diagnostic trouble codes and refer to this
type information system blockage diagnostic trouble code index
Spark plug(s) fouled or Check the fuel system for blockages, repair as
failed required
Injector(s) circuit short Check the catalyst/exhaust system for blockage,
to ground, short to repair as required
power, open circuit Check and install a new spark plug(s) as
Injector(s) failure required
Fuel system Refer to the electrical circuit diagrams and
excessively too lean or check injector(s) circuit for short to ground,
too rich power, open circuit
Camshaft position Check and install a new injector(s) as required
sensor failure Check for air leaks within the intake system
Check and install a new camshaft position
sensor as required

P0306- Cylinder 6 Misfire Poor fuel quality Check engine control module for related misfire
00 Detected - No sub Catalyst/exhaust diagnostic trouble codes and refer to this
type information system blockage diagnostic trouble code index
Spark plug(s) fouled or Check the fuel system for blockages, repair as
failed required
Injector(s) circuit short Check the catalyst/exhaust system for blockage,
to ground, short to repair as required
power, open circuit Check and install a new spark plug(s) as
Injector(s) failure required
Fuel system Refer to the electrical circuit diagrams and
excessively too lean or check injector(s) circuit for short to ground,
too rich power, open circuit
Camshaft position Check and install a new injector(s) as required
sensor failure Check for air leaks within the intake system
Check and install a new camshaft position
sensor as required

P0313- Misfire Detected Poor fuel quality Check engine control module for related misfire
00 With Low Fuel - Catalyst/exhaust diagnostic trouble codes and refer to this
No sub type system blockage diagnostic trouble code index
information Spark plug(s) fouled or Check the fuel system for blockages, repair as
failed required
Injector(s) circuit short Check the catalyst/exhaust system for blockage,
to ground, short to repair as required
power, open circuit Check and install a new spark plug(s) as
Injector(s) failure required
Fuel system Refer to the electrical circuit diagrams and
excessively too lean or check injector(s) circuit for short to ground,
too rich power, open circuit
Camshaft position Check and install a new injector(s) as required
sensor failure Check for air leaks within the intake system
Check and install a new camshaft position
sensor as required

P0316- Misfire Detected Poor fuel quality Check engine control module for related misfire
00 On Startup (First Catalyst/exhaust diagnostic trouble codes and refer to this
1000 Revolutions) - system blockage diagnostic trouble code index
No sub type Spark plug(s) fouled or Check the fuel system for blockages, repair as
information failed required
Injector(s) circuit short Check the catalyst/exhaust system for blockage,
to ground, short to repair as required
power, open circuit Check and install a new spark plug(s) as
Injector(s) failure required
Fuel system Refer to the electrical circuit diagrams and
excessively too lean or check injector(s) circuit for short to ground,
too rich power, open circuit
Camshaft position Check and install a new injector(s) as required
sensor failure Check for air leaks within the intake system
Check and install a new camshaft position
sensor as required

P0327- Knock Sensor 1 Poor sensor contact Ensure a good electrical contact with the
00 Circuit Low with the cylinder block cylinder block. Refer to the electrical circuit
(Bank1) - No sub Knock sensor circuit - diagrams and check knock sensor circuits for
type information short to ground short to ground. Check and install a new knock
Knock sensor failure sensor as required

P0328- Knock Sensor 1 Poor sensor contact Ensure a good electrical contact with the
00 Circuit High (Bank with the cylinder block cylinder block. Refer to the electrical circuit
1) - No sub type Knock sensor circuit - diagrams and check knock sensor circuits for
information high resistance, short short to power, high resistance. Check and
to power install a new knock sensor as required
Knock sensor failure

P0332- Knock Sensor 2 Poor sensor contact Ensure a good electrical contact with the
00 Circuit Low (Bank with the cylinder block cylinder block. Refer to the electrical circuit
2) - No sub type Knock sensor circuit - diagrams and check knock sensor circuits for
information short to ground short to ground. Check and install a new knock
Knock sensor failure sensor as required

P0333- Knock Sensor 2 Poor sensor contact Ensure a good electrical contact with the
00 Circuit High (Bank with the cylinder block cylinder block. Refer to the electrical circuit
2) - No sub type Knock sensor circuit - diagrams and check knock sensor circuits for
information high resistance, short short to power, high resistance. Check and
to power install a new knock sensor as required
Knock sensor failure

P0335- Crankshaft Position Crankshaft position Refer to the electrical circuit diagrams and
92 Sensor A Circuit - sensor circuit - short to check crankshaft position sensor circuit for
Performance or ground, short to short to ground, short to power, high resistance,
incorrect operation power, high resistance, disconnected connector. Check crankshaft
disconnected position sensor for damage and check air gap
Crankshaft position (check at 90° intervals, should be no greater
sensor gap incorrect, than 4.5mm). Check and install a new
foreign matter on crankshaft position sensor as required
sensor face, damaged
teeth on rotor
Crankshaft position
sensor failure

P0335- Crankshaft Position Crankshaft position Refer to the electrical circuit diagrams and
94 Sensor A Circuit - sensor circuit - short to check crankshaft position sensor circuit for
Unexpected ground, short to short to ground, short to power, high resistance,
operation power, high resistance, disconnected connector. Check crankshaft
disconnected position sensor for damage and check air gap
Crankshaft position (check at 90° intervals, should be no greater
sensor gap incorrect, than 4.5mm). Check and install a new
foreign matter on crankshaft position sensor as required
sensor face, damaged
teeth on rotor
Crankshaft position
sensor failure

P0336- Crankshaft Position Crankshaft position Refer to the electrical circuit diagrams and
00 Sensor A Circuit sensor circuit - short to check crankshaft position sensor circuit for
Range/Performance ground, short to short to ground, short to power, high resistance,
- No sub type power, high resistance, disconnected connector. Check crankshaft
information disconnected position sensor for damage and check air gap
Crankshaft position (check at 90° intervals, should be no greater
sensor gap incorrect, than 4.5mm). Check and install a new
foreign matter on crankshaft position sensor as required
sensor face, damaged
teeth on rotor
Crankshaft position
sensor failure

P0340- Camshaft Position Camshaft position Refer to the electrical circuit diagrams and
92 Sensor A Circuit sensor circuit - short to check camshaft position sensor circuit for short
(Bank 1 or single ground, short to to ground, short to power, high resistance,
sensor) - power, high resistance, disconnected connector. Check camshaft
Performance or disconnected position sensor for correct installation and
incorrect operation Camshaft position damage. Check and install a new camshaft
sensor gap incorrect, position sensor as required
foreign matter on
sensor face, damaged
rotor
Camshaft position
sensor failure

P0340- Camshaft Position Camshaft position Refer to the electrical circuit diagrams and
94 Sensor A Circuit sensor circuit - short to check camshaft position sensor circuit for short
(Bank 1 or single ground, short to to ground, short to power, high resistance,
sensor) - power, high resistance, disconnected connector. Check camshaft
Unexpected disconnected position sensor for correct installation and
operation Camshaft position damage. Check and install a new camshaft
sensor gap incorrect, position sensor as required
foreign matter on
sensor face, damaged
rotor
Camshaft position
sensor failure

P0341- Camshaft Position Camshaft position Refer to the electrical circuit diagrams and
00 Sensor A Circuit sensor circuit - short to check camshaft position sensor circuit for short
Range/Performance ground, short to to ground, short to power, high resistance,
(Bank 1 or single power, high resistance, disconnected connector. Check camshaft
sensor) - No sub disconnected position sensor for correct installation and
type information Camshaft position damage. Check and install a new camshaft
sensor gap incorrect, position sensor as required
foreign matter on
sensor face, damaged
rotor
Camshaft position
sensor failure

P0345- Camshaft Position Camshaft position Refer to the electrical circuit diagrams and
92 Sensor A Circuit sensor circuit - short to check camshaft position sensor circuit for short
(Bank 2) - ground, short to to ground, short to power, high resistance,
Performance or power, high resistance, disconnected connector. Check camshaft
incorrect operation disconnected position sensor for correct installation and
Camshaft position damage. Check and install a new camshaft
sensor gap incorrect, position sensor as required
foreign matter on
sensor face, damaged
rotor
Camshaft position
sensor failure

P0345- Camshaft Position Camshaft position Refer to the electrical circuit diagrams and
94 Sensor A Circuit sensor circuit - short to check camshaft position sensor circuit for short
(Bank 2) - ground, short to to ground, short to power, high resistance,
Unexpected power, high resistance, disconnected connector. Check camshaft
operation disconnected position sensor for correct installation and
Camshaft position damage. Check and install a new camshaft
sensor gap incorrect, position sensor as required
foreign matter on
sensor face, damaged
rotor
Camshaft position
sensor failure

P0346- Camshaft Position Camshaft position Refer to the electrical circuit diagrams and
00 Sensor A Circuit sensor circuit - short to check camshaft position sensor circuit for short
Range/Performance ground, short to to ground, short to power, high resistance,
(Bank 2) - No sub power, high resistance, disconnected connector. Check camshaft
type information disconnected position sensor for correct installation and
Camshaft position damage. Check and install a new camshaft
sensor gap incorrect, position sensor as required
foreign matter on
sensor face, damaged
rotor
Camshaft position
sensor failure

P0351- Ignition Coil A Ignition module/coil Refer to the electrical circuit diagrams and
00 Primary/Secondary circuits - short to check ignition module/coil circuits for short to
Circuit - No sub ground, power, high ground, power, high resistance
type information resistance

P0352- Ignition Coil B Ignition module/coil Refer to the electrical circuit diagrams and
00 Primary/Secondary circuits - short to check ignition module/coil circuits for short to
Circuit - No sub ground, power, high ground, power, high resistance
type information resistance

P0353- Ignition Coil C Ignition module/coil Refer to the electrical circuit diagrams and
00 Primary/Secondary circuits - short to check ignition module/coil circuits for short to
Circuit - No sub ground, power, high ground, power, high resistance
type information resistance

P0354- Ignition Coil D Ignition module/coil Refer to the electrical circuit diagrams and
00 Primary/Secondary circuits - short to check ignition module/coil circuits for short to
Circuit - No sub ground, power, high ground, power, high resistance
type information resistance

P0355- Ignition Coil E Ignition module/coil Refer to the electrical circuit diagrams and
00 Primary/Secondary circuits - short to check ignition module/coil circuits for short to
Circuit - No sub ground, power, high ground, power, high resistance
type information resistance

P0356- Ignition Coil F Ignition module/coil Refer to the electrical circuit diagrams and
00 Primary/Secondary circuits - short to check ignition module/coil circuits for short to
Circuit - No sub ground, power, high ground, power, high resistance
type information resistance

P0413- Secondary Air AIR vacuum solenoid Refer to the electrical circuit diagrams and
00 Injection Switching control circuit high check AIR vacuum solenoid control circuit for
Valve A Circuit short to power
Open - No sub type
information
P0414- Secondary Air AIR vacuum solenoid Refer to the electrical circuit diagrams and
00 Injection Switching control circuit low check AIR vacuum solenoid control circuit for
Valve A Circuit short to ground, high resistance
Shorted - No sub
type information
P0420- Catalytic converter Catalytic converter Check for misfire/lean combustion diagnostic
00 System Efficiency failure due to trouble codes and refer to diagnostic trouble
Below Threshold overheating damage code index in this section. Check the oil and
(Bank 1) - No sub caused by misfire fuel condition/level. Check the catalytic
type information and/or lean converter for damage
combustion
Catalytic converter
failure due to
poisoning caused by
excessive oil
consumption and/or
contaminated fuel

P0430- Catalytic converter Catalytic converter Check for misfire/lean combustion diagnostic
00 System Efficiency failure due to trouble codes and refer to diagnostic trouble
Below Threshold overheating damage code index in this section. Check the oil and
(Bank 2) - No sub caused by misfire fuel condition/level. Check the catalytic
type information and/or lean converter for damage
combustion
Catalytic converter
failure due to
poisoning caused by
excessive oil
consumption and/or
contaminated fuel

P0441- Evaporative Purge valve - Refer to the electrical circuit diagrams and
00 Emission System range/performance check EVAP purge valve control circuit for
Incorrect Purge short, open circuit
Flow - No sub type
information
P0458- Evaporative Purge valve circuit Refer to the electrical circuit diagrams and
00 Emission System short circuit to ground check the purge valve circuit for short circuit to
Purge Control ground
Valve Circuit Low
- No sub type
information
P0459- Evaporative Purge valve circuit Refer to the electrical circuit diagrams and
00 Emission System short circuit to power check the purge valve circuit for short circuit to
Purge Control power
Valve Circuit High
- No sub type
information
P0461- Fuel Level Sensor Fuel level sensor Refer to the electrical circuit diagrams and
29 A Circuit failure check fuel level sensor circuits for short, open
Range/Performance circuit, high resistance
- Signal invalid
P0461- Fuel Level Sensor Fuel level sensor Refer to the electrical circuit diagrams and
2F A Circuit failure check fuel level sensor circuits for short, open
Range/Performance circuit, high resistance
- Signal erratic
P0462- Fuel Level Sensor Fuel level sensor Refer to the electrical circuit diagrams and
00 A Circuit Low - No failure check fuel level sensor circuits for short, open
sub type circuit, high resistance
information
P0463- Fuel Level Sensor Fuel level sensor Refer to the electrical circuit diagrams and
00 A Circuit High - failure check fuel level sensor circuits for short, open
No sub type circuit, high resistance
information
P0480- Fan 1 Control Electric cooling fan Refer to the electrical circuit diagrams and
23 Circuit - Signal control circuit - short check electric cooling fan control circuit for
stuck low to ground, high short to ground, high resistance
resistance

P0480- Fan 1 Control Electric cooling fan Refer to the electrical circuit diagrams and
24 Circuit - Signal control circuit - short check electric cooling fan control circuit for
stuck high to power short to power

P0483- Fan Performance - Cooling fan difficult to CLEAR any obstruction and Check and install a
09 Component turn/obstructed new fan as required
Failures Fan/Motor damaged

P0483- Fan Performance - Cooling fan control Check the battery is in fully charged and
16 Circuit voltage module reports battery serviceable condition. Refer to the electrical
below threshold voltage less than nine circuit diagrams and check the charging system
volts and cooling fan circuits for short, open circuit

P0483- Fan Performance - Fan control module Refer to the electrical circuit diagrams and
17 Circuit voltage reports battery voltage check the charging system and cooling fan
above threshold greater than 18 volts circuits for short, open circuit

P0483- Fan Performance - Cooling fan jammed Clear any obstruction from cooling fan
97 Component or
system operation
obstructed or
blocked
P0500- Vehicle Speed Vehicle speed - invalid Check anti-lock brake system for related
82 Sensor A - Alive / signal received over diagnostic trouble codes and refer to relevant
sequence counter CAN diagnostic trouble code index
incorrect / not
updated
P0500- Vehicle Speed Vehicle speed - invalid Check anti-lock brake system for related
86 Sensor A - Signal signal received over diagnostic trouble codes and refer to relevant
invalid CAN diagnostic trouble code index

P0501- Vehicle Speed Vehicle speed - range Check anti-lock brake system/transmission
00 Sensor A performance control module for related diagnostic trouble
Range/Performance codes and refer to relevant diagnostic trouble
- No sub type code index
information Check reluctor rings and sensors on each wheel
for damage or excessive dirt. Repair or replace
as required. Clear DTC and retest
Refer to the warranty policy and procedures
manual, or determine if any prior approval
programme is in operation, prior to the
installation of a new module/component

P0501- Vehicle Speed Vehicle speed - range Check anti-lock brake system/transmission
62 Sensor A performance control module for related diagnostic trouble
Range/Performance codes and refer to relevant diagnostic trouble
- Signal compare code index
failure Check reluctor rings and sensors on each wheel
for damage or excessive dirt. Repair or replace
as required. Clear DTC and retest
Refer to the warranty policy and procedures
manual, or determine if any prior approval
programme is in operation, prior to the
installation of a new module/component

P0504- Brake Switch A / B The brake pressure Refer to the electrical circuit diagrams and
00 Correlation - No reading does not agree check brake switch circuits for short, open
sub type with the brake light circuit, high resistance
information switch value

P0504- Brake Switch A / B Brake switch high Refer to the electrical circuit diagrams and
01 Correlation - fault: check brake switch circuits for short, open
General Electrical Brake lights circuit, high resistance
Failure stuck on
Gearshift
interlock
inoperative
Speed control
inoperative
Brake switch low
fault:
Brake lights
inoperative
Gearshift stuck
in Park
Reduced engine
braking

P0506- Idle Control Air intake restriction Ensure the air intake system is free from
00 System - RPM Front end accessory restriction. Repair/replace as required, clear
lower than drive overload caused DTC and retest
expected by defective or seized Check the front end accessory drive belt and
component associated components for failure.
Repair/replace as required, clear DTC and retest
Check for under-fuelling and rectify as required
Refer to the warranty policy and procedures
manual, or determine if any prior approval
programme is in operation, prior to the
installation of a new module/component

P0507- Idle Control Intake air leak between Check for leakage and correct installation of air
00 System - RPM mass air flow sensor intake system. Repair/replace as required, clear
higher than and engine DTC and retest
expected Engine crankcase Check for leakage and correct installation of
breather leak engine crankcase breather system.
Repair/replace as required, clear DTC and retest
Check for over-fuelling and rectify as required
Refer to the warranty policy and procedures
manual, or determine if any prior approval
programme is in operation, prior to the
installation of a new module/component

P0512- Starter Request Crank request circuit - Refer to the electrical circuit diagrams and
12 Circuit - Circuit short to power check crank request circuit for short to power
short to battery
P0512- Starter Request Crank request circuit - Refer to the electrical circuit diagrams and
14 Circuit - Circuit short to ground, open check crank request circuit for short to ground,
short to ground or circuit open circuit
open
P0513- Incorrect Security key invalid Check for CAN network interference/EMC
00 Immobilizer Key - related error. Re-synchronise ID by re-
No sub type configuring the engine control module and
information instrument cluster as new modules

P0560- System Voltage - Engine control module Refer to the electrical circuit diagrams and
13 Circuit open power supply circuit - check engine control module power supply
open circuit circuit for open circuit

P0561- System Voltage System voltage Check for sensor 5 volt supply related
00 Unstable - No sub comparison diagnostic trouble codes and refer to diagnostic
type information trouble code index in this section

P0562- System Voltage Sensor 5 volt power Refer to the electrical circuit diagrams and
00 Low - No sub type supply circuit - low check sensor 5 volt power supply circuit for
information input short to ground, open circuit

P0563- System Voltage Sensor 5 volt power Refer to the electrical circuit diagrams and
00 High - No sub type supply circuit - high check sensor 5 volt power supply circuit for
information input short to power

P0575- Cruise Control General electrical Check speed control system for related
01 Input Circuit - failure diagnostic trouble codes and refer to relevant
General Electrical CAN network circuit diagnostic trouble code index. Carry out CAN
Failure failure network integrity tests using the manufacturer
approved diagnostic system

P0576- Cruise Control Circuit voltage below Check speed control system for related
16 Input Circuit Low - threshold diagnostic trouble codes and refer to relevant
Circuit voltage diagnostic trouble code index. Carry out CAN
below threshold network integrity tests using the manufacturer
approved diagnostic system

P0577- Cruise Control Circuit voltage above Check speed control system for related
17 Input Circuit High - threshold diagnostic trouble codes and refer to relevant
Circuit voltage diagnostic trouble code index. Carry out CAN
above threshold network integrity tests using the manufacturer
approved diagnostic system

P0578- Cruise Control One of speed control Check for stuck speed control switch, install a
00 Multi-Function switches stuck new switch pack as required
Input A Circuit
Stuck - No sub type
information
P0579- Cruise Control Speed control switch Check and install a new speed control switch
1C Multi-Function pack internal failure pack as required
Input A Circuit
Range/Performance
- Circuit voltage
out of range
P0590- Cruise Control Active speed limiter Check for active speed limiter fault, install a
00 Multi-Function fault new transmission shift module as required
Input B Circuit
Stuck - No sub type
information
P0601- Internal Control Special memory If the diagnostic trouble code resets suspect the
43 Module Memory failure engine control module, refer to the new
Check Sum Error - module/component installation note at top of
Special memory diagnostic trouble code index
failure
P0601- Internal Control Program memory If the diagnostic trouble code resets suspect the
45 Module Memory failure engine control module, refer to the new
Check Sum Error - module/component installation note at top of
Program memory diagnostic trouble code index
failure
P0604- Internal Control General memory If the diagnostic trouble code resets suspect the
42 Module Random failure engine control module, refer to the new
Access Memory module/component installation note at top of
(RAM) Error - diagnostic trouble code index
General memory
failure
P0604- Internal Control Special memory If the diagnostic trouble code resets suspect the
43 Module Random failure engine control module, refer to the new
Access Memory module/component installation note at top of
(RAM) Error - diagnostic trouble code index
Special memory
failure
P0604- Internal Control Data memory failure If the diagnostic trouble code resets suspect the
44 Module Random engine control module, refer to the new
Access Memory module/component installation note at top of
(RAM) Error - diagnostic trouble code index
Data memory
failure
P0604- Internal Control Program memory If the diagnostic trouble code resets suspect the
45 Module Random failure engine control module, refer to the new
Access Memory module/component installation note at top of
(RAM) Error - diagnostic trouble code index
Program memory
failure
P0605- Internal Control EEPROM/flash Re-configure the engine control module using
00 Module Read Only checksum error the manufacturer approved diagnostic system
Memory (ROM)
Error - No sub type
information
P0605- Internal Control Signal invalid If the diagnostic trouble code resets suspect the
29 Module Read Only engine control module, refer to the new
Memory (ROM) module/component installation note at top of
Error - Signal diagnostic trouble code index
invalid
P0605- Internal Control General memory If the diagnostic trouble code resets suspect the
42 Module Read Only failure engine control module, refer to the new
Memory (ROM) module/component installation note at top of
Error - General diagnostic trouble code index
memory failure
P0605- Internal Control Special memory If the diagnostic trouble code resets suspect the
43 Module Read Only failure engine control module, refer to the new
Memory (ROM) module/component installation note at top of
Error - Special diagnostic trouble code index
memory failure
P0605- Internal Control Data memory failure If the diagnostic trouble code resets suspect the
44 Module Read Only engine control module, refer to the new
Memory (ROM) module/component installation note at top of
Error - Data diagnostic trouble code index
memory failure
P0605- Internal Control Program memory If the diagnostic trouble code resets suspect the
45 Module Read Only failure engine control module, refer to the new
Memory (ROM) module/component installation note at top of
Error - Program diagnostic trouble code index
memory failure
P0605- Internal Control Calibration/parameter If the diagnostic trouble code resets suspect the
46 Module Read Only memory failure engine control module, refer to the new
Memory (ROM) module/component installation note at top of
Error - Calibration / diagnostic trouble code index
parameter memory
failure
P0605- Internal Control Supervision software If the diagnostic trouble code resets suspect the
48 Module Read Only failure engine control module, refer to the new
Memory (ROM) module/component installation note at top of
Error - Supervision diagnostic trouble code index
software failure
P0605- Internal Control Signal plausibility If the diagnostic trouble code resets suspect the
64 Module Read Only failure engine control module, refer to the new
Memory (ROM) module/component installation note at top of
Error - Signal diagnostic trouble code index
plausibility failure
P0606- ECM/PCM No sub type If the diagnostic trouble code resets suspect the
00 Processor - No sub information engine control module, refer to the new
type information module/component installation note at top of
diagnostic trouble code index

P0606- ECM/PCM General Electrical If the diagnostic trouble code resets suspect the
01 Processor - General Failure engine control module, refer to the new
electrical failure module/component installation note at top of
diagnostic trouble code index

P0606- ECM/PCM System Internal If the diagnostic trouble code resets suspect the
04 Processor - System Failures engine control module, refer to the new
internal failures module/component installation note at top of
diagnostic trouble code index
P0606- ECM/PCM System Programming If the diagnostic trouble code resets suspect the
05 Processor - System Failures engine control module, refer to the new
programming module/component installation note at top of
failures diagnostic trouble code index

P0606- ECM/PCM General checksum If the diagnostic trouble code resets suspect the
41 Processor - General failure engine control module, refer to the new
checksum failure module/component installation note at top of
diagnostic trouble code index

P0606- ECM/PCM General memory If the diagnostic trouble code resets suspect the
42 Processor - General failure engine control module, refer to the new
memory failure module/component installation note at top of
diagnostic trouble code index

P0606- ECM/PCM Special memory If the diagnostic trouble code resets suspect the
43 Processor - Special failure engine control module, refer to the new
memory failure module/component installation note at top of
diagnostic trouble code index

P0606- ECM/PCM Data memory failure If the diagnostic trouble code resets suspect the
44 Processor - Data engine control module, refer to the new
memory failure module/component installation note at top of
diagnostic trouble code index

P0606- ECM/PCM Program memory If the diagnostic trouble code resets suspect the
45 Processor - failure engine control module, refer to the new
Program memory module/component installation note at top of
failure diagnostic trouble code index

P0606- ECM/PCM Calibration/parameter If the diagnostic trouble code resets suspect the
46 Processor - memory failure engine control module, refer to the new
Calibration / module/component installation note at top of
parameter memory diagnostic trouble code index
failure
P0606- ECM/PCM Watchdog/safety If the diagnostic trouble code resets suspect the
47 Processor - MicroController engine control module, refer to the new
Watchdog / safety failure module/component installation note at top of
MicroController diagnostic trouble code index
failure
P0606- ECM/PCM Supervision software If the diagnostic trouble code resets suspect the
48 Processor - failure engine control module, refer to the new
Supervision module/component installation note at top of
software failure diagnostic trouble code index

P0606- ECM/PCM Internal electronic If the diagnostic trouble code resets suspect the
49 Processor - Internal failure engine control module, refer to the new
electronic failure module/component installation note at top of
diagnostic trouble code index

P0607- Control Module No sub type If the diagnostic trouble code resets suspect the
00 Performance - No information engine control module, refer to the new
sub type module/component installation note at top of
information diagnostic trouble code index
P060A- Internal Control No sub type Clear the diagnostic trouble code and retest. If
00 Module Monitoring information the DTC resets, suspect the engine control
Processor module, check and install a new module as
Performance - No required, refer to new module/component
sub type installation note at top of diagnostic trouble
information code index

P060A- Internal Control Signal plausibility Clear the diagnostic trouble code and retest. If
64 Module Monitoring failure the DTC resets, suspect the engine control
Processor module, check and install a new module as
Performance - required, refer to new module/component
Signal plausibility installation note at top of diagnostic trouble
failure code index

P060A- Internal Control Signal incorrect after Clear the diagnostic trouble code and retest. If
67 Module Monitoring event the diagnostic trouble code resets, suspect the
Processor engine control module, check and install a new
Performance - module as required, refer to new
Signal incorrect module/component installation note at top of
after event diagnostic trouble code index

P060D- Internal Control APS Communication Refer to the electrical circuit diagrams and
00 Module check the accelerator pedal position sensor
Accelerator Pedal circuits for short, open circuit, high resistance
Position
Performance - No
sub type
information
P060E- Internal Control Signal compare failure Refer to the electrical circuit diagrams and
62 Module Throttle check throttle position sensor circuits for short,
Position open circuit, high resistance
Performance -
Signal compare
failure
P060E- Internal Control Signal plausibility Refer to the electrical circuit diagrams and
64 Module Throttle failure check throttle position sensor circuits for short,
Position open circuit, high resistance
Performance -
Signal plausibility
failure
P0610- Control Module Special memory Re-configure the rear junction box using the
43 Vehicle Options failure manufacturer approved diagnostic system
Error - Special
memory failure
P0616- Starter Relay Starter relay circuit - Refer to the electrical circuit diagrams and
14 Circuit Low - short to ground, open check starter relay circuit for short to ground,
Circuit short to circuit open circuit
ground or open
P0617- Starter Relay Starter relay circuit - Refer to the electrical circuit diagrams and
12 Circuit High - short to power check starter relay circuit for short to power
Circuit short to
battery
P061A- Internal Control No sub type If the diagnostic trouble code resets suspect the
00 Module Torque information engine control module, refer to the new
Performance - No module/component installation note at top of
sub type diagnostic trouble code index
information
P061A- Internal Control Signal invalid If the diagnostic trouble code resets suspect the
29 Module Torque engine control module, refer to the new
Performance - module/component installation note at top of
Signal invalid diagnostic trouble code index

P061A- Internal Control Signal plausibility If the diagnostic trouble code resets suspect the
64 Module Torque failure engine control module, refer to the new
Performance - module/component installation note at top of
Signal plausibility diagnostic trouble code index
failure
P061B- Internal Control Signal invalid If the diagnostic trouble code resets suspect the
29 Module Torque engine control module, refer to the new
Calculation module/component installation note at top of
Performance - diagnostic trouble code index
Signal invalid
P061B- Internal Control Signal plausibility If the diagnostic trouble code resets suspect the
64 Module Torque failure engine control module, refer to the new
Calculation module/component installation note at top of
Performance - diagnostic trouble code index
Signal plausibility
failure
P0620- Generator Control Generator B+ or Check for good/clean contact at generator B+
01 Circuit - General battery terminal and battery terminal connectors. Refer to the
electrical failure disconnected/poor electrical circuit diagrams and check charging
connection circuit for short, open circuit. Clear diagnostic
Charging circuit - trouble code and repeat automated diagnostic
short, open circuit procedure using the manufacturer approved
Generator failure diagnostic system. If diagnostic trouble code
remains suspect the generator, check and install
a new generator as required, refer to the new
module/component installation note at the top
of the diagnostic trouble code index

P0627- Fuel Pump A Fuel pump control Refer to the electrical circuit diagrams and
00 Control circuit fault fuel pump check the fuel pump driver module to engine
Circuit/Open - No driver module to control module circuit for short to ground,
sub type engine control module power, open circuit
information
P062A- Fuel Pump A Invalid fuel pump duty Refer to the electrical circuit diagrams and
00 Control Circuit requested by the check the fuel pump driver module to engine
Range/Performance engine control module control module circuit for short to ground,
- No sub type power, open circuit
information
P0630- VIN Not CCF to CAN VIN Configure the engine control module using the
00 Programmed or mismatch manufacturer approved diagnostic system, clear
Incompatible - diagnostic trouble code and re-test, if diagnostic
ECM/PCM - No trouble code remains suspect the engine control
sub type module. Check and install a new engine control
information module as required, refer to the new
module/component installation note at the top
of the diagnostic trouble code index

P065B- Generator Control Charging circuit - Refer to the electrical circuit diagrams and
16 Circuit short, open circuit check charging circuit for short, open circuit.
Range/Performance Quiescent current high Clear diagnostic trouble code and repeat
- Circuit voltage Battery damaged/worn automated diagnostic procedure using the
below threshold out manufacturer approved diagnostic system. If
Generator failure diagnostic trouble code remains check battery is
in fully charged and serviceable condition using
the Midtronics battery tester and battery care
manual. If ok suspect the generator, check and
install a new generator as required, refer to the
new module/component installation note at the
top of the diagnostic trouble code index

P065B- Generator Control Charging circuit - Check engine control module for over charging
17 Circuit short, open circuit related diagnostic trouble codes and refer to the
Range/Performance Generator/engine relevant diagnostic trouble code index. Clear
- Circuit voltage control module failure diagnostic trouble code and re-test, if diagnostic
above threshold trouble code remains suspect the generator.
Check and install a new generator as required,
refer to the new module/component installation
note at the top of the diagnostic trouble code
index

P065C- Generator Poor front end Check front end accessory drive belt
00 Mechanical accessory drive belt condition/contamination and for correct tension.
Performance - No tension Check generator pulley for failure. Clear
sub type Generator pulley diagnostic trouble code and repeat automated
information loose/failure diagnostic procedure using manufacturer
Generator failure approved diagnostic system. If diagnostic
trouble code remains check and install a new
generator as required, refer to the new
module/component installation note at the top
of the diagnostic trouble code index

P0661- Intake Manifold Intake manifold tuning Refer to the electrical circuit diagrams and
00 Tuning Valve valve control circuit check intake manifold tuning valve control
Control Circuit bank 1 - short to circuit bank 1 for short to power, open circuit
Low - Bank 1 - No power, open circuit
sub type
information
P0662- Intake Manifold Intake manifold tuning Refer to the electrical circuit diagrams and
00 Tuning Valve valve control circuit check intake manifold tuning valve control
Control Circuit bank 1 - short to circuit bank 1 for short to ground
High - Bank 1 - No ground
sub type
information
P0664- Intake Manifold Intake manifold tuning Refer to the electrical circuit diagrams and
00 Tuning Valve valve control circuit check intake manifold tuning valve control
Control Circuit bank 2 - short to circuit bank 2 for short to power, open circuit
Low - Bank 2 - No power, open circuit
sub type
information
P0665- Intake Manifold Intake manifold tuning Refer to the electrical circuit diagrams and
00 Tuning Valve valve control circuit check intake manifold tuning valve control
Control Circuit bank 2 - short to circuit bank 2 for short to ground
High - Bank 2 - No ground
sub type
information
P0687- ECM/PCM Power EMS relay stuck Refer to electrical circuit diagrams and check
73 Relay Control closed EMS relay control circuit for short to ground
Circuit High -
Actuator stuck
closed
P0721- Output Shaft Speed Signal invalid Check the transmission control module for
86 Sensor Circuit related diagnostic trouble codes and refer to the
Range/Performance relevant diagnostic trouble code index
- Signal invalid
P0817- Starter Disable Starter relay negative Refer to the electrical circuit diagrams and
13 Circuit/Open - control circuit - open check starter relay negative control circuit for
Circuit open circuit open circuit

P081A- Starter Disable Starter relay negative Refer to the electrical circuit diagrams and
11 Circuit Low - control circuit - short check starter relay negative control circuit for
Circuit short to to ground short to ground
ground
P081B- Starter Disable Starter relay negative Refer to the electrical circuit diagrams and
12 Circuit High - control circuit - short check starter relay negative control circuit for
Circuit short to to power short to power
battery
P0831- Clutch Pedal Park/Neutral switch Refer to the electrical circuit diagrams and
00 Switch A Circuit input circuit - low check Park/Neutral switch input circuit for short
Low - No sub type to ground, open circuit
information
P0832- Clutch Pedal Park/Neutral switch Refer to the electrical circuit diagrams and
00 Switch A Circuit input circuit - high check Park/Neutral switch input circuit for short
High - No sub type to power
information
P0850- Park/Neutral Park/Neutral switch Refer to the electrical circuit diagrams and
86 Switch Input input circuit - signal check Park/Neutral switch input circuit for short
Circuit - Signal invalid to ground, power, open circuit
invalid
P0850- Park/Neutral Park/Neutral switch Refer to the electrical circuit diagrams and
8F Switch Input input circuit - erratic check Park/Neutral switch input circuit for short
Circuit - Erratic to ground, power, open circuit

P0851- Park/Neutral Park/Neutral switch Refer to the electrical circuit diagrams and
14 Switch Input input circuit - low check Park/Neutral switch input circuit for short
Circuit Low - to ground, open circuit
Circuit short to
ground or open
P0852- Park / Neutral Park/Neutral switch Refer to the electrical circuit diagrams and
12 Switch Input input circuit - high check Park/Neutral switch input circuit for short
Circuit High - to power
Circuit short to
battery
P0A1A- Generator Control Generator to engine Check for good/clean contact at generator and
87 Module - Missing control module LIN engine control module LIN circuit
message circuit - open circuit connectors/pins. Refer to the electrical circuit
Generator/engine diagrams and check generator to engine control
control module failure module LIN circuit for open circuit. Check for
engine control module hardware diagnostic
trouble codes and refer to relevant diagnostic
trouble code index. Clear diagnostic trouble
codes and repeat automated diagnostic
procedure using the manufacturer approved
diagnostic system. If diagnostic trouble code
remains check and install a new
generator/engine control module as required,
refer to the new module/component installation
note at the top of the diagnostic trouble code
index

P0A1A- Generator Control Generator to engine Check for good/clean contact at generator and
88 Module - Bus off control module LIN engine control module LIN circuit
circuit - open circuit connectors/pins. Refer to the electrical circuit
Engine control module diagrams and check generator to engine control
LIN bus failure module LIN circuit for open circuit. Check for
Generator/engine engine control module hardware diagnostic
control module failure trouble codes and refer to relevant diagnostic
trouble code index. Clear diagnostic trouble
codes and repeat automated diagnostic
procedure using the manufacturer approved
diagnostic system. If diagnostic trouble code
remains check and install a new
generator/engine control module as required,
refer to the new module/component installation
note at the top of the diagnostic trouble code
index

P0A3B- Generator Over Generator Check the generator wiring and connectors for
68 Temperature - wiring/connectors heat heat damage. Clear the diagnostic trouble code
Event information damaged and repeat the automated diagnostic procedure
Generator failure using the manufacturer approved diagnostic
system. If diagnostic trouble code remains
check and install a new generator as required,
refer to the new module/component installation
note at the top of the diagnostic trouble code
index

P1259- Immobilizer to Incorrect ID received Re-configure the instrument cluster using the
00 PCM Signal Error - from instrument manufacturer approved diagnostic system
No sub type cluster
information
P1315- Persistent Misfire - Engine control module Check for cylinder mis-fire, ignition and
00 No sub type to ignition coil primary injector diagnostic trouble codes and refer to the
information circuit fault (cylinder diagnostic trouble code index. Check for fuel
misfire detected system failure. Check and install spark plug as
diagnostic trouble required. Carry out cylinder compression tests
code also flagged)
Fuel injector circuit
fault(s) (injector
diagnostic trouble
codes also flagged)
Fuel delivery pressure
low
Spark plug
failure/fouled/incorrect
gap
Cylinder compression
low

P1316- Misfire Rate Misfire rate exceeds Check for individual cylinder misfire diagnostic
00 Exceeds Emissions emissions thresholds trouble codes and refer to diagnostic trouble
- No sub type code index in this section
information
P1367- Ignition Spare - No Ignition module/coil Refer to the electrical circuit diagrams and
00 sub type monitoring circuit 1 - check ignition module/coil monitoring circuit 1
information short to ground, short for short to ground, short to power, high
to power, high resistance
resistance

P1368- Ignition Spare - No Ignition module/coil Refer to the electrical circuit diagrams and
00 sub type monitoring circuit 2 - check ignition module/coil monitoring circuit 2
information short to ground, short for short to ground, short to power, high
to power, high resistance
resistance

P1603- EEPROM Engine control module Suspect the engine control module, check and
00 Malfunction - No fault install a new module as required. Refer to the
sub type new module/component installation note at top
information of diagnostic trouble code index

P2101- Throttle Actuator Signal invalid Refer to the electrical circuit diagrams and test
29 Control Motor Jammed throttle blade, throttle actuator control motor circuit for short
Circuit gearing or motor to ground, power, high resistance. Suspect the
Range/Performance throttle body, check and install a new throttle
- Signal invalid body as required, refer to the new
module/component installation note at the top
of the diagnostic trouble code index

P2101- Throttle Actuator Signal compare failure Refer to the electrical circuit diagrams and test
62 Control Motor Jammed throttle blade, throttle actuator control motor circuit for short
Circuit gearing or motor to ground, power, high resistance. Suspect the
Range/Performance throttle body, check and install a new throttle
- Signal compare body as required, refer to the new
failure module/component installation note at the top
of the diagnostic trouble code index

P2101- Throttle Actuator Signal plausibility Refer to the electrical circuit diagrams and test
64 Control Motor failure throttle actuator control motor circuit for short
Circuit Jammed throttle blade, to ground, power, high resistance. Suspect the
Range/Performance gearing or motor throttle body, check and install a new throttle
- Signal plausibility body as required, refer to the new
failure module/component installation note at the top
of the diagnostic trouble code index

P2101- Throttle Actuator Commanded position Refer to the electrical circuit diagrams and test
77 Control Motor not achievable throttle actuator control motor circuit for short
Circuit Throttle blade stuck to ground, power, high resistance. Suspect the
Range/Performance open throttle body, check and install a new throttle
- Commanded Intake air system leak body as required, refer to the new
position not module/component installation note at the top
reachable of the diagnostic trouble code index

P2103- Throttle Actuator Signal invalid Refer to the electrical circuit diagrams and
29 Control Motor Throttle motor control check throttle motor control circuit for short to
Circuit High - circuit - short to power power. If engine control module is suspect,
Signal invalid Engine control module check and install a new module as required,
fault refer to new module/component installation
note at top of diagnostic trouble code index

P2103- Throttle Actuator Signal plausibility Refer to the electrical circuit diagrams and
64 Control Motor failure check throttle motor control circuit for short to
Circuit High - Throttle motor control power. If engine control module is suspect,
Signal plausibility circuit - short to power check and install a new module as required,
failure Engine control module refer to new module/component installation
fault note at top of diagnostic trouble code index

P2105- Throttle Actuator Throttle MIL request Check for any diagnostic trouble codes
00 Control System - due to fuel cut referring to engine control module, throttle
Forced Engine pedal position sensor, or torque faults and refer
Shutdown - No sub to relevant diagnostic trouble code index
type information
P2118- Throttle Actuator Throttle motor control Refer to the electrical circuit diagrams and
00 Control Motor circuit - short to check throttle motor control circuit for short to
Current ground, power, high ground, power, high resistance
Range/Performance resistance
- No sub type
information
P2119- Throttle Actuator Throttle spring faulty Suspect throttle body faulty. Check and install a
00 Control Throttle new throttle body as required, refer to the new
Body module/component installation note at top of
Range/Performance diagnostic trouble code index
- No sub type
information
P2122- Throttle/Pedal Accelerator pedal Refer to the electrical circuit diagrams and
00 Position position sensor circuit check accelerator pedal position sensor circuit 2
Sensor/Switch D 2 - low input for short to ground, open circuit
Circuit Low - No
sub type
information
P2123- Throttle/Pedal Accelerator pedal Refer to the electrical circuit diagrams and
00 Position position sensor circuit check accelerator pedal position sensor circuit 2
Sensor/Switch D 2 - high input for short to power
Circuit High - No
sub type
information
P2135- Throttle/Pedal Accelerator pedal Refer to the electrical circuit diagrams and
28 Position position sensor circuit check accelerator pedal position sensor circuits
Sensor/Switch A/B 1 and 2 range 1 and 2 for short to ground, power and high
Voltage Correlation performance - sub- resistance. Clear the diagnostic trouble codes
- Signal bias level processor and retest. If the code remains, replace the
out of range / zero accelerator pedal position sensor
adjustment failure
P2135- Throttle/Pedal Accelerator pedal Refer to the electrical circuit diagrams and
29 Position position sensor - check accelerator pedal position sensor circuits
Sensor/Switch A/B excessive difference 1 and 2 for short, open circuit
Voltage Correlation between raw values of
- Signal invalid circuit 1 and 2 - sub-
processor

P2135- Throttle/Pedal Accelerator pedal Refer to the electrical circuit diagrams and
62 Position position sensor circuit check accelerator pedal position sensor circuits
Sensor/Switch A/B 1 and 2 range 1 and 2 for short to ground, power and high
Voltage Correlation performance - sub- resistance. Clear the diagnostic trouble codes
- Signal compare processor and retest. If the code remains, replace the
failure accelerator pedal position sensor

P2135- Throttle/Pedal Accelerator pedal Refer to the electrical circuit diagrams and
64 Position position sensor circuit check accelerator pedal position sensor circuits
Sensor/Switch A/B 1 and 2 range 1 and 2 for short, open circuit
Voltage Correlation performance
- Signal plausibility
failure
P2228- Barometric BARO sensor failure Suspect the engine control module, check and
00 Pressure Circuit (internal engine install a new module as required, refer to the
Low - No sub type control module fault) new module/component installation note at the
information top of the diagnostic trouble code index

P2229- Barometric BARO sensor failure Suspect the engine control module, check and
00 Pressure Circuit (internal engine install a new module as required, refer to the
High - No sub type control module fault) new module/component installation note at the
information top of the diagnostic trouble code index

P2444- Secondary Air Secondary air injection Refer to the electrical circuit diagrams and
00 Injection System pump control circuit - check secondary air injection pump control
Pump Stuck On short to ground circuit for short to ground
Bank 1 - No sub
type information
P2445- Secondary Air Secondary air injection Refer to the electrical circuit diagrams and
00 Injection System pump control circuit - check secondary air injection pump control
Pump Stuck Off short to power circuit for short to power
Bank 1 - No sub
type information
P2610- ECM/PCM Internal Instrument cluster Check for diagnostic trouble codes related to
64 Engine Off Timer fault any of the components listed, and refer to
Performance - Engine coolant relevant diagnostic trouble code index. Refer to
Signal plausibility temperature sensor the electrical circuit diagrams and check engine
failure fault coolant temperature sensor, ambient air
Ambient temperature temperature sensor circuits for short, open
sensor fault circuit. Carry out the CAN network integrity
Body processor test using the manufacturer approved diagnostic
module fault (time) system
CAN error

P2610- ECM/PCM Internal Instrument cluster Check for diagnostic trouble codes related to
87 Engine Off Timer fault any of the components listed, and refer to
Performance - Engine coolant relevant diagnostic trouble code index. Refer to
Missing message temperature sensor the electrical circuit diagrams and check engine
fault coolant temperature sensor, ambient air
Ambient temperature temperature sensor circuits for short, open
sensor fault circuit. Carry out the CAN network integrity
Body processor test using the manufacturer approved diagnostic
module fault (time) system
CAN error

U0001- High Speed CAN High speed CAN bus Refer to the electrical circuit diagrams and
88 Communication circuit, short to ground check CAN network for short, open circuit.
Bus - Bus off High speed CAN bus Carry out CAN network integrity test using the
circuit, short to power manufacturer approved diagnostic system
High speed CAN bus,
open circuit

U0101- Lost CAN Link engine Refer to the electrical circuit diagrams and
00 Communication control check power and ground supplies to
with TCM - No sub module/transmission transmission control module. Carry out the
type information control module CAN network integrity test using the
network malfunction manufacturer approved diagnostic system

U0103- Lost CAN Link engine Refer to the electrical circuit diagrams and
00 Communication control module/gear check power and ground supplies to
With Gear Shift shift network transmission shift module. Carry out the CAN
Module - No sub malfunction network integrity test using the manufacturer
type information approved diagnostic system

U0104- Lost CAN Link engine Refer to the electrical circuit diagrams and
00 Communication control module/speed check power and ground supplies to speed
With Cruise control module control module. Carry out the CAN network
Control Module - network malfunction integrity test using the manufacturer approved
No sub type diagnostic system
information
U0121- Lost CAN Link engine Refer to the electrical circuit diagrams and
00 Communication control module/anti- check power and ground supplies to anti-lock
With Anti-Lock lock brake system brake system module. Carry out the CAN
Brake System module network network integrity test using the manufacturer
(ABS) Control malfunction approved diagnostic system
Module - No sub
type information
U0128- Lost CAN Link engine Refer to the electrical circuit diagrams and
00 Communication control check power and ground supplies to parking
With Park Brake module/Electronic brake module. Carry out the CAN network
Control Module - parking brake signal integrity test using the manufacturer approved
No sub type missing network diagnostic system
information malfunction

U0151- Lost Lost communication - Refer to the electrical circuit diagrams and
00 Communication CAN or hardwired check power and ground supplies to restraints
With Restraints control module. Carry out the CAN network
Control Module - integrity test using the manufacturer approved
No sub type diagnostic system
information
U0151- Lost Lost communication - Refer to the electrical circuit diagrams and
87 Communication SRS fault check power and ground supplies to restraints
With Restraints control module. Carry out the CAN network
Control Module - integrity test using the manufacturer approved
Missing message diagnostic system
U0155- Lost CAN Link engine Refer to the electrical circuit diagrams and
00 Communication control check power and ground supplies to instrument
With Instrument module/instrument cluster. Carry out the CAN network integrity
Panel Cluster (IPC) cluster network test using the manufacturer approved diagnostic
Control Module - malfunction system
No sub type
information
U0164- Lost No sub type Refer to electrical circuit diagrams and check
00 Communication information power and ground feeds to heating ventilation
With HVAC air and conditioning control module. Carry out
Control Module - the CAN network integrity test using the
No sub type manufacturer approved diagnostic system.
information Check heating ventilation air and conditioning
control module for diagnostic trouble codes and
refer to the relevant diagnostic trouble code
index

U0167- Lost Security challenge Refer to the electrical circuit diagrams and
00 Communication response timeout check power and ground supplies to vehicle
With Vehicle immobilizer module. Carry out the CAN
Immobilizer network integrity test using the manufacturer
Control Module - approved diagnostic system
No sub type
information
U0300- Internal Control The engine control Check and install the correct engine control
00 Module Software module is in expulsion module as required, refer to the new
Incompatibility - mode. An incorrect module/component installation note at the top
No sub type specification module of the diagnostic trouble code index
information has been installed to
the vehicle

U0402- Invalid Data Transmission control Check transmission control module for related
08 Received from module engine speed diagnostic trouble codes and refer to relevant
TCM - Bus Signal / control monitor diagnostic trouble code index
Message Failures
U0402- Invalid Data Actual gear position Check transmission control module for related
64 Received from status diagnostic trouble codes and refer to relevant
TCM - Signal diagnostic trouble code index
plausibility failure
U0402- Invalid Data Selector lever position Check transmission control module for related
67 Received from status diagnostic trouble codes and refer to relevant
TCM - Signal diagnostic trouble code index
incorrect after
event
U0402- Invalid Data Output shaft speed Check transmission control module for related
81 Received from signal diagnostic trouble codes and refer to relevant
TCM - Invalid diagnostic trouble code index
serial data received
U0402- Invalid Data Alive/sequence Check transmission control module for related
82 Received from counter incorrect/not diagnostic trouble codes and refer to relevant
TCM - Alive / updated diagnostic trouble code index
sequence counter
incorrect / not
updated
U0402- Invalid Data Transmission control Check transmission control module for related
83 Received from module engine speed diagnostic trouble codes and refer to relevant
TCM - Value of control monitor - diagnostic trouble code index
signal protection plausibility
calculation
incorrect
U0402- Invalid Data Transmission control Check transmission control module for related
86 Received from module engine speed diagnostic trouble codes and refer to relevant
TCM - Signal control monitor - diagnostic trouble code index
invalid rationality

U0405- Invalid Data Invalid data received Check speed control module for related
81 Received From from speed control diagnostic trouble codes and refer to relevant
Cruise Control module diagnostic trouble code index
Module - Invalid
serial data received
U0405- Invalid Data Invalid data received Check speed control module for related
83 Received From from speed control diagnostic trouble codes and refer to relevant
Cruise Control module diagnostic trouble code index
Module - Value of
signal protection
calculation
incorrect
U0405- Invalid Data Invalid data received Check speed control module for related
8F Received From from speed control diagnostic trouble codes and refer to relevant
Cruise Control module diagnostic trouble code index
Module - Erratic
U0415- Invalid Data Brake Position Switch Check anti-lock brake system module for
00 Received From related diagnostic trouble codes and refer to
Anti-Lock Brake relevant diagnostic trouble code index
System (ABS)
Control Module -
No sub type
information
U0415- Invalid Data Engine drag torque Check anti-lock brake system module for
64 Received From control monitoring - related diagnostic trouble codes and refer to
Anti-Lock Brake plausibility relevant diagnostic trouble code index
System Control
Module - Signal
plausibility failure
U0415- Invalid Data Engine drag torque Check anti-lock brake system module for
67 Received From control monitoring - related diagnostic trouble codes and refer to
Anti-Lock Brake rationality relevant diagnostic trouble code index
System Control
Module - Signal
incorrect after
event
U0423- Invalid Data Battery voltage level Check instrument cluster for related diagnostic
86 Received From trouble codes and refer to relevant diagnostic
Instrument Panel trouble code index
Control Module -
Signal invalid
U0424- Invalid Data External ambient Check heating ventilation air and conditioning
81 Received From temperature control module for related diagnostic trouble
HVAC Control codes and refer to relevant diagnostic trouble
Module - Invalid code index
serial data received
U0426- Invalid Data Security code mis- Check CAN network between engine control
00 Received From match module and instrument cluster. Check power
Vehicle and grounds to engine control module and
Immobilizer instrument cluster. Check correct engine control
Control Module - module and instrument cluster installed. Re-
No sub type synchronise ID by re-configuring the engine
information control module and instrument cluster as new
modules
Published: 11-Apr-2019

2012.0 XF (X250), 100-00

General Information

Diagnostic Trouble Code Index - DTC: Engine


Control Module - 5.0L NA V8 - AJ133 (PCM) (G2133665)
DESCRIPTION AND OPERATION
Engine Control Module (PCM) 5.0L NA V8 - AJ133
WARNING:

Fuel injector voltage will reach 65 Volts during operation and have a high current requirement.

CAUTION:

Diagnosis by substitution from a donor vehicle is NOT acceptable. Substitution of control modules does not
guarantee confirmation of a fault, and may also cause additional faults in the vehicle being tested and/or the donor
vehicle

NOTES:

If the control module or a component is suspect and the vehicle remains under manufacturer warranty, refer to
the Warranty Policy and Procedures manual, or determine if any prior approval programme is in operation,
prior to the installation of a new module/component.

Generic scan tools may not read the codes listed, or may read only five digit codes. Match the five digits from
the scan tool to the first five digits of the seven digit code listed to identify the fault (the last two digits give
additional information read by the manufacturer-approved diagnostic system).

When performing electrical voltage or resistance tests, always use a digital multimeter (DMM) accurate to
three decimal places, and with an up-to-date calibration certificate. When testing resistance, always take the
resistance of the DMM leads into account.

Check and rectify basic faults before beginning diagnostic routines involving pinpoint tests.

If DTCs are recorded and, after performing the pinpoint tests, a fault is not present, an intermittent concern
may be the cause. Always check for loose connections and corroded terminals.

Check DDW for open campaigns. Refer to the corresponding bulletins and SSMs which may be valid for the
specific customer complaint and carry out the recommendations as required.

The table below lists all diagnostic trouble codes (DTCs) that could be logged in the electronic engine control
module, for additional diagnosis and testing information refer to the relevant diagnosis and testing section. For
additional information, refer to: Electronic Engine Controls (303-14D Electronic Engine Controls - V8 N/A 5.0L
Petrol, Diagnosis and Testing).

DTC Description Possible Causes Action


B10A2- Crash Input - No NOTE: Refer to the electrical circuit
31 signal diagrams and check restraints
- Circuit SRS_SIGNAL - control module pulse width
modulated SRS signal line
Loss of communication between circuit, hard wired connection
restraints control module and engine between engine control module
control module and restraints control module
for short circuit to ground, short
circuit to power, open circuit.
Repair circuit as required, clear
the DTC and retest

B10AC- Cruise Control The engine control module has Clear the DTC and press all the
81 Switch - Invalid received an invalid command from the steering wheel switches, re-
serial data received steering wheel switch pack check for DTCs. Refer to the
electrical circuit diagrams and
check the speed control switch
circuit for open circuit, short
circuit to power, short circuit to
ground, disconnected
Check and install a new
steering wheel module as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

B10AC- Cruise Control Cruise buttons alive counter is not Refer to the electrical circuit
82 Switch - Alive / incrementing. Which suggests that the diagrams and check the speed
sequence counter LIN bus is faulty control switch circuit for open
incorrect / not Steering wheel module is not circuit, short circuit to power,
updated connected short circuit to ground,
Steering wheel module failure disconnected
Refer to the electrical circuit
diagrams and check the LIN
bus between steering wheel
module and the CAN gateway
Check and install a new
steering wheel module as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

B10AC- Cruise Control Cruise buttons checksum incorrect, Check and install new cruise
83 Switch - Value of incorrect cruise switches fitted to switches as required. Refer to
signal protection vehicle the warranty policy and
calculation procedures manual, or
incorrect determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

B10AC- Cruise Control Speed control switch circuit, open Check for related DTCs in
96 Switch - circuit, short circuit to power, short other central junction boxes
Component internal circuit to ground, disconnected Refer to the electrical circuit
failure Speed control switch failure diagrams and check the speed
Steering wheel module failure control switch circuit for open
circuit, short circuit to power,
short circuit to ground,
disconnected
Check and install a new speed
control switch as required.
Check and install a new
steering wheel module as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

B10FF- Ignition Control - Spark plug(s) fault Refer to repair manual and
68 Event information Wiring harness fault check spark plug(s) for
Ignition coil(s) fault condition and security. Replace
any defective components as
required
Refer to electrical wiring
diagrams and check ignition
coil circuit for intermittent open
circuit, short circuit to power,
short circuit to ground
Check and install a new coil(s)
as required. Refer to the
warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

B11DB- Battery Monitoring NOTE: Refer to electrical wiring


01 Module - General diagrams and check charging
electrical failure - Circuit BATTERY - system for faults. Perform any
repairs required
Charging system fault Refer to the electrical wiring
Battery monitoring signal line circuit diagrams and check the battery
fault monitoring system module
Vehicle battery fault circuit for open circuit, short
circuit to ground, short circuit
to power
Refer to the workshop manual
and the battery care manual,
inspect the vehicle battery and
ensure it is fully charged and
serviceable before performing
further tests

B11DB- Battery Monitoring NOTE: Refer to the electrical wiring


87 Module - Missing diagrams and check the battery
message - Circuit BATTERY - monitoring system module
circuit for open circuit, short
Battery signal line circuit fault circuit to ground, short circuit
to power
Refer to the electrical circuit
diagrams and check the LIN
circuit for short circuit to
ground, short circuit to power,
open circuit

B1206- Crash Occurred - NOTE: Refer to the electrical circuit


68 Event information diagrams and check the engine
- Circuit SRS_SIGNAL - control module to restraints
control module circuit for short
Engine control module has detected the circuit to ground, short circuit
vehicle has crashed - event information to power, open circuit. Repair
DTC only circuit as required, clear the
DTC and retest

C0031- Left Front Wheel Invalid data received from anti-lock Check anti-lock braking system
00 Speed Sensor - No braking system module - left front module for related DTCs and
sub type wheel speed signal fault refer to relevant DTC index
information
C0034- Right Front Wheel Invalid data received from anti-lock Check anti-lock braking system
00 Speed Sensor - No braking system module - right front module for related DTCs and
sub type wheel speed signal fault refer to relevant DTC index
information
C0037- Left Rear Wheel Invalid data received from anti-lock Check anti-lock braking system
00 Speed Sensor - No braking system module - left rear module for related DTCs and
sub type wheel speed signal fault refer to relevant DTC index
information
C003A- Right Rear Wheel Invalid data received from anti-lock Check anti-lock braking system
00 Speed Sensor - No braking system module - right rear module for related DTCs and
sub type wheel speed signal fault refer to relevant DTC index
information
P0010- Intake (A) NOTE: Refer to the electrical circuit
13 Camshaft Position diagrams and check intake (A)
Actuator (Bank 1) - - Circuit VFS_IN_A - camshaft position actuator
Circuit open (Bank 1) circuit for open circuit
Intake (A) camshaft position actuator Refer to the electrical circuit
(Bank 1) open circuit diagrams and check engine
Engine control module interface control module interface
harness open circuit harness for open circuit

P0011- Intake (A) NOTE: Refer to the electrical circuit


00 Camshaft Position diagrams and check intake (A)
Timing - Over- - Circuit VFS_IN_A - camshaft position actuator
Advanced (Bank 1) (Bank 1) circuit for open circuit
- No sub type Intake (A) camshaft position actuator Refer to the electrical circuit
information (Bank 1) open circuit diagrams and check engine
Engine control module interface control module interface
harness open circuit harness for open circuit

P0013- Exhaust (B) NOTE: Refer to the electrical circuit


13 Camshaft Position diagrams and check exhaust (B)
Actuator (Bank 1) - - Circuit VFS_EX_A - camshaft position actuator
Circuit open (Bank 1) circuit for open circuit
Exhaust (B) camshaft position actuator Refer to the electrical circuit
(Bank 1) open circuit diagrams and check engine
Engine control module interface control module interface
harness open circuit harness for open circuit

P0015- Exhaust (B) NOTE: Check for related DTC P0365-


00 Camshaft Position 00. Refer to the electrical
Timing - Over- - Circuit VFS_EX_A - circuit diagrams and check
Retarded (Bank 1) - exhaust (B) camshaft position
No sub type Exhaust (B) camshaft position actuator actuator (Bank 1) for open
information (Bank 1) open circuit, short circuit to circuit, short circuit to ground,
ground, short circuit to power short circuit to power

P0016- Crankshaft Position NOTE: Check engine timing. Check


00 - Camshaft Position camshaft sensor timing plate is
Correlation - Bank - Circuit VFS_IN_A - installed correctly. Check
1 Sensor A - No timing chain is installed
sub type The relative positions of the crankshaft correctly
information position sensor and cam timing plate
teeth are not correct
Engine timing incorrect
Timing chain installed incorrectly
Variable valve timing forced fully
advanced

P0017- Crankshaft Position NOTE: Check for related DTC P0365-


00 - Camshaft Position 00. Check engine timing.
Correlation - Bank - Circuit VFS_EX_A - Check camshaft sensor timing
1 Sensor B - No plate is installed correctly.
sub type The relative positions of the crankshaft Check timing chain is installed
information position sensor and camshaft timing correctly
plate teeth are not correct Refer to the electrical circuit
Engine timing incorrect diagrams and check exhaust (B)
Timing chain installed incorrectly camshaft position actuator
Variable valve timing forced fully (Bank 1) for open circuit, short
advanced circuit to ground, short circuit
to power

P0018- Crankshaft Position NOTE: Check engine timing. Check


00 - Camshaft Position camshaft sensor timing plate is
Correlation - Bank - Circuit VFS_IN_B - installed correctly. Check
2 Sensor A - No timing chain is installed
sub type The relative positions of the crankshaft correctly
information position sensor and camshaft timing
plate teeth are not correct
Engine timing incorrect
Timing chain installed incorrectly
Variable valve timing forced fully
advanced

P0019- Crankshaft Position NOTE: Check engine timing. Check


00 - Camshaft Position camshaft sensor timing plate is
Correlation - Bank - Circuit VFS_EX_B - installed correctly. Check
2 Sensor B - No timing chain is installed
sub type The relative positions of the crankshaft correctly
information position sensor and camshaft timing
plate teeth are not correct
Engine timing incorrect
Timing chain installed incorrectly
Variable valve timing forced fully
advanced

P001A- Intake (A) Cam NOTE: Refer to the electrical circuit


13 Profile Control diagrams and check camshaft
Circuit (Bank 1) - - Circuit CPS_A - profile switching solenoid bank
Circuit open 1 for open circuit
Camshaft profile switching solenoid
bank 1 open circuit

P001B- Intake (A) Cam NOTE: Refer to the electrical circuit


11 Profile Control diagrams and check camshaft
Circuit Low (Bank - Circuit CPS_A - profile switching solenoid bank
1) - Circuit short to 1 circuit for short circuit to
ground Camshaft profile switching solenoid ground
bank 1 circuit short circuit to ground

P001C- Intake (A) Cam NOTE: Refer to the electrical circuit


12 Profile Control diagrams and check camshaft
Circuit High (Bank - Circuit CPS_A - profile switching solenoid bank
1) - Circuit short to 1 circuit for short circuit to
battery Camshaft profile switching solenoid power
bank 1 circuit short circuit to power

P001D- Intake (A) Cam NOTE: Refer to the electrical circuit


13 Profile Control diagrams and check camshaft
Circuit (Bank 2) - - Circuit CPS_B - profile switching solenoid bank
Circuit open 2 for open circuit
Camshaft profile switching solenoid
bank 2 open circuit

P001E- Intake (A) Cam NOTE: Refer to the electrical circuit


11 Profile Control diagrams and check camshaft
Circuit Low (Bank - Circuit CPS_B - profile switching solenoid bank
2) - Circuit short to 2 circuit for short circuit to
ground Camshaft profile switching solenoid ground
bank 2 circuit short circuit to ground

P001F- Intake (A) Cam NOTE: Refer to the electrical circuit


12 Profile Control diagrams and check camshaft
Circuit High (Bank - Circuit CPS_B - profile switching solenoid bank
2) - Circuit short to 2 circuit for short circuit to
battery Camshaft profile switching solenoid power
bank 2 circuit short circuit to power

P0020- Intake (A) NOTE: Refer to the electrical circuit


13 Camshaft Position diagrams and check intake
Actuator (Bank 2) - - Circuit VFS_IN_B - valve solenoid 2 for open
Circuit open circuit
Intake valve solenoid 2 open circuit

P0023- Exhaust (B) NOTE: Refer to the electrical circuit


13 Camshaft Position diagrams and check exhaust (B)
Actuator (Bank 2) - - Circuit VFS_EX_B - camshaft position actuator
Circuit open (Bank 2) circuit for open circuit
Exhaust (B) Camshaft Position
actuator (Bank 2) circuit, open circuit

P0026- Intake Valve NOTE: Check operation of intake valve


72 Control Solenoid solenoid 1. Check and install a
Circuit - Circuit VFS_IN_A - new intake valve solenoid 1 as
Range/Performance required. Refer to the warranty
(Bank 1) - Actuator Intake valve solenoid 1 angle less than policy and procedures manual,
stuck open target or determine if any prior
Intake valve solenoid 1 slow or not approval programme is in
operating operation, prior to the
installation of a new
module/component

P0026- Intake Valve NOTE: Check operation of intake valve


77 Control Solenoid solenoid 1. Check and install a
Circuit - Circuit VFS_IN_A - new intake valve solenoid 1 as
Range/Performance required. Refer to the warranty
(Bank 1) - Intake valve solenoid 1 angle greater policy and procedures manual,
Commanded than target or determine if any prior
position not Intake valve solenoid 1 not returning to approval programme is in
reachable target in time operation, prior to the
Intake valve solenoid 1 stuck advanced installation of a new
module/component

P0027- Exhaust Valve NOTE: Check operation of exhaust


72 Control Solenoid valve solenoid 1. Check and
Circuit - Circuit VFS_EX_A - install a new exhaust valve
Range/Performance solenoid 1 as required. Refer to
(Bank 1) - Actuator Exhaust valve solenoid 1 angle less the warranty policy and
stuck open than target procedures manual, or
Exhaust valve solenoid 1 slow or not determine if any prior approval
operating programme is in operation,
prior to the installation of a new
module/component

P0027- Exhaust Valve NOTE: Check operation of exhaust


77 Control Solenoid valve solenoid 1. Check and
Circuit - Circuit VFS_EX_A - install a new exhaust valve
Range/Performance solenoid 1 as required. Refer to
(Bank 1) - Exhaust valve solenoid 1 angle greater the warranty policy and
Commanded than target procedures manual, or
position not Exhaust valve solenoid 1 not returning determine if any prior approval
reachable to target in time programme is in operation,
Exhaust valve solenoid 1 stuck prior to the installation of a new
advanced module/component

P0028- Intake Valve NOTE: Check operation of intake valve


72 Control Solenoid solenoid 2. Check and install a
Circuit - Circuit VFS_IN_B - new intake valve solenoid 2 as
Range/Performance required. Refer to the warranty
(Bank 2) - Actuator Intake valve solenoid 2 angle less than policy and procedures manual,
stuck open target or determine if any prior
Intake valve solenoid 2 slow or not approval programme is in
operating operation, prior to the
installation of a new
module/component

P0028- Intake Valve NOTE: Check operation of intake valve


77 Control Solenoid solenoid 2. Check and install a
Circuit - Circuit VFS_IN_B - new intake valve solenoid 2 as
Range/Performance required. Refer to the warranty
(Bank 2) - Intake valve solenoid 2 angle greater policy and procedures manual,
Commanded than target or determine if any prior
position not Intake valve solenoid 2 not returning to approval programme is in
reachable target in time operation, prior to the
Intake valve solenoid 2 stuck advanced installation of a new
module/component

P0029- Exhaust Valve NOTE: Check operation of exhaust


72 Control Solenoid valve solenoid 2. Check and
Circuit - Circuit VFS_EX_B - install a new exhaust valve
Range/Performance solenoid 2 as required. Refer to
(Bank 2) - Actuator Exhaust valve solenoid 2 angle less the warranty policy and
stuck open than target procedures manual, or
Exhaust valve solenoid 2 slow or not determine if any prior approval
operating programme is in operation,
prior to the installation of a new
module/component

P0029- Exhaust Valve NOTE: Check operation of exhaust


77 Control Solenoid valve solenoid 2. Check and
Circuit - Circuit VFS_EX_B - install a new exhaust valve
Range/Performance solenoid 2 as required. Refer to
(Bank 2) - Exhaust valve solenoid 2 angle greater the warranty policy and
Commanded than target procedures manual, or
position not Exhaust valve solenoid 2 not returning determine if any prior approval
reachable to target in time programme is in operation,
Exhaust valve solenoid 2 stuck prior to the installation of a new
advanced module/component

P0031- HO2S Heater NOTES: Using the Jaguar Land Rover


11 Control Circuit approved diagnostic equipment
Low (Bank 1, - Circuit HTR_CTRL_A_UPSTREAM check datalogger signal,
Sensor 1) - Circuit - Oxygen Sensor (O2S) Heater
short to ground Duty Cycle Bank 1 Sensor 1
LR - Circuit UHEGO HEATER A - (0x03A1)
Refer to the electrical circuit
Pre catalyst oxygen sensor-odd heater diagrams and check pre catalyst
control circuit (Bank 1, Sensor 1) oxygen sensor-odd heater
circuit short circuit to ground control circuit (Bank 1, Sensor
1) circuit for short circuit to
ground

P0031- HO2S Heater NOTES: Using the Jaguar Land Rover


13 Control Circuit approved diagnostic equipment
Low (Bank 1, - Circuit HTR_CTRL_A_UPSTREAM check datalogger signal,
Sensor 1) - Circuit - Oxygen Sensor (O2S) Heater
open Duty Cycle Bank 1 Sensor 1
LR - Circuit UHEGO HEATER A - (0x03A1)
Refer to the electrical circuit
Pre catalyst oxygen sensor-odd heater
diagrams and check pre catalyst
control circuit (Bank 1, Sensor 1) oxygen sensor-odd heater
circuit, open circuit control circuit (Bank 1, Sensor
1) circuit for open circuit

P0032- HO2S Heater NOTES: Using the Jaguar Land Rover


12 Control Circuit approved diagnostic equipment
High (Bank 1, - Circuit HTR_CTRL_A_UPSTREAM check datalogger signal,
Sensor 1) - Circuit - Oxygen Sensor (O2S) Heater
short to battery Duty Cycle Bank 1 Sensor 1
LR - Circuit UHEGO HEATER A - (0x03A1)
Refer to the electrical circuit
Pre catalyst oxygen sensor-odd heater diagrams and check pre catalyst
control circuit (Bank 1, Sensor 1) oxygen sensor-odd heater
circuit short circuit to power control circuit (Bank 1, Sensor
1) circuit for short circuit to
power

P0036- HO2S Heater NOTE: Using the Jaguar Land Rover


00 Control Circuit approved diagnostic equipment
(Bank 1, Sensor 2) - Circuit HTR_HEGO_A - check datalogger signal,
- No sub type Oxygen Sensor (O2S) Heater
information Catalyst oxygen sensor heater circuit Duty Cycle Bank 1 Sensor 2
control fuse failure (0x03A2)
Post catalyst oxygen sensor-odd heater Refer to the electrical circuit
control circuit short circuit to ground, diagrams and check post
short circuit to power, open circuit catalyst oxygen sensor-odd
Catalyst oxygen sensor heater circuit sensor fuse for open circuit
control relay circuit short circuit to Refer to the electrical circuit
ground, short circuit to power, open diagrams and check post
circuit catalyst oxygen sensor-odd
Catalyst oxygen sensor heater circuit sensor circuit for short circuit to
control relay failure ground, short circuit to power,
Post catalyst oxygen sensor-odd failure open circuit
Refer to the electrical circuit
diagrams and check catalyst
oxygen sensor heater circuit
control relay circuit for short
circuit to ground, short circuit
to power, open circuit
Check and install a new catalyst
oxygen sensor heater control
relay, as required. Check and
install a new post catalyst
oxygen sensor-odd as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P003C- A Camshaft Profile NOTE: Check for the presence of oil at


00 Control the camshaft profile switching
Performance /Stuck - Circuit CPS_A - solenoid
Off (Bank 1) - No Check for catalyst oxygen
sub type Oil supply blockage to camshaft sensor related DTCs
information profile switching solenoid Refer to the electrical circuit
Catalyst oxygen sensor failure, giving diagrams and check camshaft
false flag profile switching solenoid bank
Camshaft profile switching solenoid 1 circuit for short circuit to
bank 1 circuit fault power, short circuit to ground,
Camshaft profile switching solenoid open circuit
bank 1 fault Check and install a new
camshaft profile switching
solenoid bank 1 as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component
Clear DTC and road test the
vehicle. If fault remains contact
dealer technical support before
carrying out any further work

P003E- A Camshaft Profile NOTE: Check for the presence of oil at


00 Control the camshaft profile switching
Performance/ Stuck - Circuit CPS_B - solenoid
Off (Bank 2) - No Check for catalyst oxygen
sub type Oil supply blockage to camshaft sensor related DTCs
information profile switching solenoid Refer to the electrical circuit
Catalyst oxygen sensor failure, giving diagrams and check camshaft
false flag profile switching solenoid bank
Camshaft profile switching solenoid 2 circuit for short circuit to
bank 2 circuit fault power, short circuit to ground,
Camshaft profile switching solenoid open circuit
bank 2 fault Check and install a new
camshaft profile switching
solenoid bank 2 as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component
Clear DTC and road test the
vehicle. If fault remains contact
dealer technical support before
carrying out any further work

P0051- HO2S Heater NOTES: Using the Jaguar Land Rover


11 Control Circuit approved diagnostic equipment
Low (Bank 2, - Circuit HTR_CTRL_B_UPSTREAM check datalogger signal,
Sensor 1) - Circuit - Oxygen Sensor (O2S) Heater
short to ground Duty Cycle Bank 2 Sensor 1
LR - Circuit UHEGO HEATER B - (0x03A4)
Refer to the electrical circuit
Pre catalyst oxygen sensor-even heater diagrams and check pre catalyst
control circuit (Bank 2, Sensor 1) oxygen sensor-even heater
circuit short circuit to ground control circuit (Bank 2, Sensor
1) circuit for short circuit to
ground
P0051- HO2S Heater NOTES: Using the Jaguar Land Rover
13 Control Circuit approved diagnostic equipment
Low (Bank 2, - Circuit HTR_CTRL_B_UPSTREAM check datalogger signal,
Sensor 1) - Circuit - Oxygen Sensor (O2S) Heater
open Duty Cycle Bank 2 Sensor 1
LR - Circuit UHEGO HEATER B - (0x03A4)
Refer to the electrical circuit
Pre catalyst oxygen sensor-even heater diagrams and check pre catalyst
control circuit (Bank 2, Sensor 1) oxygen sensor-even heater
circuit, open circuit control circuit (Bank 2, Sensor
1) circuit for open circuit

P0052- HO2S Heater NOTES: Using the Jaguar Land Rover


12 Control Circuit approved diagnostic equipment
High (Bank 2, - Circuit HTR_CTRL_B_UPSTREAM check datalogger signal,
Sensor 1) - Circuit - Oxygen Sensor (O2S) Heater
short to battery Duty Cycle Bank 2 Sensor 1
LR - Circuit UHEGO HEATER B - (0x03A4)
Refer to the electrical circuit
Pre catalyst oxygen sensor-even heater diagrams and check pre catalyst
control circuit (Bank 2, Sensor 1) oxygen sensor-even heater
circuit short circuit to power control circuit (Bank 2, Sensor
1) circuit for short circuit to
power

P0054- HO2S Heater NOTES: Using the Jaguar Land Rover


00 Resistance (Bank 1, approved diagnostic equipment
Sensor 2) - No sub - Circuit HTR_CTRL_A_UPSTREAM check datalogger signal,
type information - Oxygen Sensor (O2S) Heater
Duty Cycle Bank 1 Sensor 1
LR - Circuit UHEGO HEATER A - (0x03A1)
Refer to the electrical circuit
Catalyst oxygen sensor heater circuit diagrams and check post
control fuse failure catalyst oxygen sensor-odd
Post catalyst oxygen sensor-odd heater sensor fuse for open circuit
control circuit short circuit to ground, Refer to the electrical circuit
short circuit to power, open circuit, diagrams and check post
high resistance catalyst oxygen sensor-odd
Catalyst oxygen sensor heater circuit sensor circuit for short circuit to
control relay circuit short circuit to ground, short circuit to power,
ground, short circuit to power, open open circuit, high resistance
circuit Refer to the electrical circuit
Catalyst oxygen sensor heater circuit diagrams and check catalyst
control relay failure oxygen sensor heater circuit
Post catalyst oxygen sensor-odd failure control relay circuit for short
circuit to ground, short circuit
to power, open circuit
Check and install a new catalyst
oxygen sensor heater control
relay, as required. Check and
install a new post catalyst
oxygen sensor-odd as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0056- HO2S Heater NOTE: Using the Jaguar Land Rover


00 Control Circuit approved diagnostic equipment
(Bank 2, Sensor 2) - Circuit HTR_HEGO_B - check datalogger signal,
- No sub type Oxygen Sensor (O2S) Heater
information Post catalyst oxygen sensor-even Duty Cycle Bank 2 Sensor 2
heater control circuit short circuit to (0x03A5)
ground, short circuit to power, open Refer to the electrical circuit
circuit diagrams and check post
Catalyst oxygen sensor heater circuit catalyst oxygen sensor-even
control relay circuit short circuit to sensor circuit for short circuit to
ground, short circuit to power, open ground, short circuit to power,
circuit open circuit
Catalyst oxygen sensor heater circuit Refer to the electrical circuit
control relay failure diagrams and check catalyst
Post catalyst oxygen sensor-even oxygen sensor heater circuit
failure control relay circuit for short
circuit to ground, short circuit
to power, open circuit
Check and install a new catalyst
oxygen sensor heater control
relay, as required. Check and
install a new post catalyst
oxygen sensor-even, as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0060- HO2S Heater NOTES: Using the Jaguar Land Rover


00 Resistance (Bank 2, approved diagnostic equipment
Sensor 2) - No sub - Circuit HTR_CTRL_B_UPSTREAM check datalogger signal,
type information - Oxygen Sensor (O2S) Heater
Duty Cycle Bank 2 Sensor 2
LR - Circuit UHEGO HEATER B - (0x03A5)
Refer to the electrical circuit
Catalyst oxygen sensor heater circuit diagrams and check post
control fuse failure catalyst oxygen sensor-even
Post catalyst oxygen sensor-even sensor fuse for open circuit
heater control circuit short circuit to Refer to the electrical circuit
ground, short circuit to power, open diagrams and check post
circuit, high resistance catalyst oxygen sensor-even
Catalyst oxygen sensor heater circuit sensor circuit for short circuit to
control relay circuit short circuit to ground, short circuit to power,
ground, short circuit to power, open open circuit, high resistance
circuit Refer to the electrical circuit
Catalyst oxygen sensor heater circuit diagrams and check catalyst
control relay failure oxygen sensor heater circuit
Post catalyst oxygen sensor-even control relay circuit for short
failure circuit to ground, short circuit
to power, open circuit
Check and install a new catalyst
oxygen sensor heater control
relay, as required. Check and
install a new post catalyst
oxygen sensor-even as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0069- MAP - Barometric Manifold absolute pressure sensor Using the Jaguar Land Rover
29 Pressure failure approved diagnostic equipment
Correlation - Signal Engine control module failure check datalogger signal,
invalid Barometric Pressure Sensor
Voltage (0x035A). Check for
related manifold absolute
pressure sensor DTCs
Refer to the electrical circuit
diagrams and check manifold
absolute pressure sensor circuit
for short circuit to ground, short
circuit to power, open circuit
Check and install new manifold
absolute pressure sensor as
required. Check and install a
new engine control module as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0071- Ambient Air NOTES: Using the Jaguar Land Rover


21 Temperature approved diagnostic equipment
Sensor Jaguar - Circuit check datalogger signal,
Range/Performance AMBIENT_TEMP_SENSOR - Ambient Air Temperature
- Signal amplitude Sensor Voltage (0x03BA)
< minimum LR - Circuit TAMB TEMP - Refer to the electrical circuit
diagrams and check ambient air
Ambient air temperature sensor circuit temperature sensor circuit for
short circuit to ground, short circuit to short circuit to ground, short
power, open circuit circuit to power, open circuit
Temperature and manifold absolute Refer to the electrical circuit
pressure sensor circuit short circuit to diagrams and check
ground, short circuit to power, open temperature and manifold
circuit absolute pressure sensor circuit
Ambient air temperature sensor failure for short circuit to ground, short
Temperature and manifold absolute circuit to power, open circuit
pressure sensor failure Check and install a new
ambient air temperature sensor
as required. Check and install a
new temperature and manifold
absolute pressure sensor as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0071- Ambient Air NOTES: Using the Jaguar Land Rover


22 Temperature approved diagnostic equipment
Sensor - Circuit AMBIENT_TEMP_SENSOR check datalogger signal,
Range/Performance - Ambient Air Temperature
- Signal amplitude Sensor Voltage (0x03BA)
> maximum LR - Circuit TAMB TEMP - Refer to the electrical circuit
diagrams and check ambient air
Ambient air temperature sensor circuit temperature sensor circuit for
short circuit to ground, short circuit to short circuit to ground, short
power, open circuit circuit to power, open circuit
Temperature and manifold absolute Refer to the electrical circuit
pressure sensor circuit short circuit to diagrams and check
ground, short circuit to power, open temperature and manifold
circuit absolute pressure sensor circuit
Ambient air temperature sensor failure for short circuit to ground, short
Temperature and manifold absolute circuit to power, open circuit
pressure sensor failure Check and install a new
ambient air temperature sensor
as required. Check and install a
new temperature and manifold
absolute pressure sensor as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0072- Ambient Air NOTES: Using the Jaguar Land Rover


00 Temperature approved diagnostic equipment
Sensor Circuit Low - Circuit AMBIENT_TEMP_SENSOR check datalogger signal,
- No sub type - Ambient Air Temperature
information Sensor Voltage (0x03BA)
LR - Circuit TAMB TEMP - Refer to the electrical circuit
diagrams and check ambient air
Ambient air temperature sensor circuit temperature sensor circuit for
short circuit to ground, open circuit, short circuit to ground, open
high resistance circuit, high resistance
Ambient air temperature sensor failure Check and install a new
ambient air temperature sensor
as required. Refer to the
warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component
P0073- Ambient Air NOTES: Using the Jaguar Land Rover
00 Temperature approved diagnostic equipment
Sensor Circuit High - Circuit AMBIENT_TEMP_SENSOR check datalogger signals
- No sub type - Ambient Air Temperature
information Sensor Voltage (0x03BA)
LR - Circuit TAMB TEMP - Refer to the electrical circuit
diagrams and check ambient air
Ambient air temperature sensor ground temperature sensor circuit for
circuit high resistance, open circuit short circuit to ground, high
Ambient air temperature sensor signal resistance, short circuit to
circuit short circuit to power power. Check connector
Ambient air temperature sensor failure terminals for corrosion or
damage
Check and install a new
ambient air temperature sensor
as required. Refer to the
warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P007B- Charge Air Cooler The engine control module measures a Leave vehicle turned off for a
23 Temperature signal that remains low when minimum of 8 hours and allow
Sensor Circuit transitions are expected to soak to a stable temperature.
Range/Performance Battery disconnection resulting in Using the Jaguar Land Rover
(Bank 1) - Signal errors in engine off time (short soaks approved diagnostic equipment
stuck low may look like long soaks) check datalogger signals -
Electric block heater applied and not Ambient Air Temperature -
detected (0xF446) - Engine Coolant
Charge air temperature sensor circuit, Temperature (0xF405) - Boost
short circuit to ground, short circuit to Air Temperature - Raw
power, open circuit, high resistance physical value (0x0341) -
Connector is disconnected, connector Intake Air Temperature
pin is backed out, connector pin (0xF40F) - Engine Coolant
corrosion Temperature #2 (0x0489). All
Charge air temperature sensor failure sensors should be within 20
degºC of each other
Refer to electrical circuit
diagrams and check the charge
air temperature sensor circuit
for short circuit to ground, short
circuit to power, open circuit,
high resistance
Inspect connectors for signs of
water ingress, and pins for
damage and/or corrosion
Check and install a new charge
air temperature sensor as
required
Using the Jaguar Land Rover
approved diagnostic equipment
clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest

P007B- Charge Air Cooler Battery disconnection resulting in Leave vehicle turned off for a
24 Temperature errors in engine off time (short soaks minimum of 8 hours and allow
Sensor Circuit may look like long soaks) to soak to a stable temperature.
Range/Performance Electric block heater applied and not Using the Jaguar Land Rover
(Bank 1) - Signal detected approved diagnostic equipment
stuck high Fuse failure check datalogger signals -
Charge air temperature sensor circuit, Ambient Air Temperature -
short circuit to ground, short circuit to (0xF446) - Engine Coolant
power, open circuit, high resistance Temperature (0xF405) - Boost
Connector is disconnected, connector Air Temperature - Raw
pin is backed out, connector pin physical value (0x0341) -
corrosion Intake Air Temperature
Charge air temperature sensor failure (0xF40F) - Engine Coolant
Air charge coolant pump and control Temperature #2 (0x0489). All
circuit, short circuit to ground, short sensors should be within 20
circuit to power, open circuit, high degºC of each other
resistance Refer to electrical circuit
Air charge coolant pump relay failure diagrams and check for fuse
Air charge coolant pump failure failure, install a new fuse as
required
Refer to electrical circuit
diagrams and check the charge
air temperature sensor circuit
for short circuit to ground, short
circuit to power, open circuit,
high resistance
Inspect connectors for signs of
water ingress, and pins for
damage and/or corrosion
Check and install a new charge
air temperature sensor as
required
Refer to electrical circuit
diagrams and check the air
charge coolant pump and
control circuit for short circuit
to ground, short circuit to
power, open circuit, high
resistance
Refer to electrical circuit
diagrams and check the air
charge coolant pump for open
circuit, high resistance
Refer to the relevant section of
the workshop manual and
check the air charge coolant
pump for correct operation.
Check and install a new air
charge coolant pump as
required
Using the Jaguar Land Rover
approved diagnostic equipment
clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest

P007B- Charge Air Cooler Battery disconnection resulting in Leave vehicle turned off for a
29 Temperature errors in engine off time (short soaks minimum of 8 hours and allow
Sensor Circuit may look like long soaks) to soak to a stable temperature.
Range/Performance Electric block heater applied and not Using the Jaguar Land Rover
(Bank 1) - Signal detected approved diagnostic equipment
invalid Fuse failure check datalogger signals -
Charge air temperature sensor circuit, Ambient Air Temperature -
short circuit to ground, short circuit to (0xF446) - Engine Coolant
power, open circuit, high resistance Temperature (0xF405) - Boost
Connector is disconnected, connector Air Temperature - Raw
pin is backed out, connector pin physical value (0x0341) -
corrosion Intake Air Temperature
Charge air temperature sensor failure (0xF40F) - Engine Coolant
Air charge coolant pump and control Temperature #2 (0x0489). All
circuit, short circuit to ground, short sensors should be within 20
circuit to power, open circuit, high degºC of each other
resistance Refer to electrical circuit
Air charge coolant pump relay failure diagrams and check for fuse
Air charge coolant pump failure failure, install a new fuse as
required
Refer to electrical circuit
diagrams and check the charge
air temperature sensor circuit
for short circuit to ground, short
circuit to power, open circuit,
high resistance
Inspect connectors for signs of
water ingress, and pins for
damage and/or corrosion
Check and install a new charge
air temperature sensor as
required
Refer to electrical circuit
diagrams and check the air
charge coolant pump and
control circuit for short circuit
to ground, short circuit to
power, open circuit, high
resistance
Refer to electrical circuit
diagrams and check the air
charge coolant pump for open
circuit, high resistance
Refer to the relevant section of
the workshop manual and
check the air charge coolant
pump for correct operation.
Check and install a new air
charge coolant pump as
required
Using the Jaguar Land Rover
approved diagnostic equipment
clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest

P0087- Fuel Rail/System NOTE: Using the Jaguar Land Rover


00 Pressure - Too Low approved diagnostic equipment
- No sub type - Circuit FUEL_HIGH_PRESS_SENSOR - check datalogger signal, Fuel
information Rail Pressure Sensor - High
Fuel rail pressure sensor circuit short Range Sensor Voltage (0x0377)
circuit to ground, open circuit, high Refer to the electrical circuit
resistance diagrams and check fuel rail
Fuel rail pressure sensor failure pressure sensor circuit for short
Fuel lines leaking or restricted circuit to ground, open circuit,
Fuel pump failure high resistance
Check for fuel pump related
DTCs. Check fuel lines for
leakage or restriction
Check and install new fuel rail
pressure sensor as required.
Check and install a new fuel
pump as required. Refer to the
warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P0088- Fuel Rail/System NOTE: Using the Jaguar Land Rover


00 Pressure - Too approved diagnostic equipment
High - No sub type - Circuit FUEL_HIGH_PRESS_SENSOR - check datalogger signal, Fuel
information Rail Pressure Sensor - High
Fuel rail pressure sensor circuit short Range Sensor Voltage (0x0377)
to each other, high resistance, short Refer to the electrical circuit
circuit to power diagrams and check fuel rail
Fuel rail pressure sensor failure pressure sensor circuit for short
to each other, high resistance,
short circuit to power
Check and install new fuel rail
pressure sensor as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P008A- Low Pressure Fuel NOTE: Using the Jaguar Land Rover
00 System Pressure - approved diagnostic equipment
Too Low - No sub - Circuit check datalogger signal, Fuel
type information LOW_PRESS_FUEL_PRESS_SENSOR - Rail Pressure - Low Range
Sensor Voltage (0x0376)
Low pressure fuel sensor circuit Check fuel system for leakage
failure, short circuit to ground, short Refer to the electrical circuit
circuit to power, open circuit diagrams and check low
Fuel pump driver module circuit short pressure fuel sensor circuit for
circuit to ground, short circuit to short circuit to ground, short
power, open circuit circuit to power, open circuit
Low pressure fuel Refer to the electrical circuit
Fuel pump driver module failure diagrams and check fuel pump
driver module circuit short
circuit to ground, short circuit
to power, open circuit
Check and install a new low
pressure fuel sensor as required.
Check and install a new fuel
pump driver module as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P008B- Low Pressure Fuel NOTE: Using the Jaguar Land Rover
00 System Pressure - approved diagnostic equipment
Too High - No sub - Circuit check datalogger signal, Fuel
type information LOW_PRESS_FUEL_PRESS_SENSOR - Rail Pressure - Low Range
Sensor Voltage (0x0376)
Low pressure fuel sensor circuit short Refer to the electrical circuit
circuit to ground, short circuit to diagrams and check low
power, open circuit pressure fuel sensor circuit for
Fuel pump driver module circuit short short circuit to ground, short
circuit to ground, short circuit to circuit to power, open circuit.
power, open circuit Check for blockage or
Blockage or restriction in low pressure restriction in low pressure fuel
fuel line line
Low pressure fuel sensor failure Refer to the electrical circuit
Fuel pump driver module failure diagrams and check fuel pump
driver module circuit short
circuit to ground, short circuit
to power, open circuit
Check and install a new low
pressure fuel sensor as required.
Check and install a new fuel
pump driver module as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P00AB- Intake Air NOTE: Using the Jaguar Land Rover


23 Temperature approved diagnostic equipment
Sensor 1 Circuit - Circuit INLET_AIR_TEMP_SENSOR_B - check datalogger signal, Intake
Range/Performance Air Temperature Sensor Bank 2
(Bank 2) - Signal Intake air temperature sensor bank 2 (0x0312)
stuck low circuit short circuit to ground, open Refer to the electrical circuit
circuit diagrams and check intake air
Intake air temperature sensor bank 2 temperature sensor bank 2
failure circuit for short circuit to
ground, open circuit
Check and install a new intake
air temperature sensor bank 2
as required. Refer to the
warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P00AB- Intake Air NOTE: Using the Jaguar Land Rover


24 Temperature approved diagnostic equipment
Sensor 1 Circuit - Circuit INLET_AIR_TEMP_SENSOR_B - check datalogger signal, Intake
Range/Performance Air Temperature Sensor Bank 2
(Bank 2) - Signal Intake air temperature sensor bank 2 (0x0312)
stuck high circuit short circuit to power Refer to the electrical circuit
Intake air temperature sensor bank 2 diagrams and check intake air
failure temperature sensor bank 2
circuit for short circuit to power
Check and install a new intake
air temperature sensor bank 2
as required. Refer to the
warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P00AB- Intake Air NOTE: Using the Jaguar Land Rover


29 Temperature approved diagnostic equipment
Sensor 1 Circuit - Circuit INLET_AIR_TEMP_SENSOR_B - check datalogger signal, Intake
Range/Performance Air Temperature Sensor Bank 2
(Bank 2) - Signal Intake air temperature sensor bank 2 (0x0312)
invalid circuit short circuit to ground, open Refer to the electrical circuit
circuit, short circuit to power diagrams and check intake air
Intake air temperature sensor bank 2 temperature sensor bank 2
failure circuit for open circuit, short
circuit to ground, short circuit
to power
Check and install a new intake
air temperature sensor bank 2
as required. Refer to the
warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P00AC- Intake Air NOTE: Using the Jaguar Land Rover


00 Temperature approved diagnostic equipment
Sensor 1 Circuit - Circuit INLET_AIR_TEMP_SENSOR_B - check datalogger signal, Intake
Low (Bank 2) - No Air Temperature Sensor Bank 2
sub type Intake air temperature sensor bank 2 (0x0312)
information sensing circuit short circuit to ground, Refer to the electrical circuit
high resistance, disconnected diagrams and check intake air
Intake air temperature sensor bank 2 temperature sensor bank 2
failure circuit for short circuit to
ground, open circuit, high
resistance, disconnected
connector
Check and install a new intake
air temperature sensor bank 2
as required. Refer to the
warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P00AD- Intake Air NOTE: Using the Jaguar Land Rover


00 Temperature approved diagnostic equipment
Sensor 1 Circuit - Circuit INLET_AIR_TEMP_SENSOR_B - check datalogger signal, Intake
High (Bank 2) - No Air Temperature Sensor Bank 2
sub type Intake air temperature sensor bank 2 (0x0312)
information sensing circuit short ground, short Refer to the electrical circuit
circuit to power, open circuit, high diagrams and check intake air
resistance temperature sensor bank 2
Intake air temperature sensor bank 2 circuit for short ground, short
failure circuit to power, open circuit,
high resistance. Check for
backed out or damaged
connector pins
Check and install a new intake
air temperature sensor bank 2
as required. Refer to the
warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P00C6- Fuel Rail Pressure No fuel at pump Check fuel supply to both
00 Too Low - Engine Injector stuck open pumps (if engine runs then
Cranking - No sub Fuel pressure sensor signal stuck supply is not suspect). If engine
type information Fuel pump failure does not run perform fuel prime
routine. Use fuel pump
diagnostic routine to determine
if one pump has failed, if so
replace pump. If a fuel injector
is stuck open the exhaust will
smell of fuel and fuelling
adaptions may indicate rich
shift. Perform checks for as
DTC P0191-00
Check and install a new fuel
pump as required. Refer to the
warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P0101- Mass or Volume Intake air distribution and filtering Using the manufacturer
00 Air Flow A Circuit components incorrectly installed approved smoke tester check
Range/Performance Leakage from intake air system intake air distribution and
- No sub type Blocked air cleaner element(s) filtering components for
information Blocked engine breather leakage and correct installation
Blockage in intake air system Check air cleaner element is
Mass air flow sensor seal failure free from restriction and in
Connector is disconnected, connector serviceable condition
terminal is backed out, connector Ensure the engine breather
terminal corrosion system is correctly installed and
Mass air flow sensor circuit, short in serviceable condition
circuit to ground, short circuit to Check for mass air flow sensor
power, open circuit, high resistance seal integrity and correct
Carbon build-up on throttle blade installation
Blocked injectors Inspect connectors for signs of
Blocked catalysts water ingress, and pins for
Mass air flow sensor failure damage and/or corrosion
Refer to the electrical circuit
diagrams and check mass air
flow sensor circuit for short
circuit to ground, short circuit
to power, open circuit, high
resistance
Make sure throttle blade is
clean of carbon
Check for blocked injectors
Check for blocked catalysts
Clear the DTC and retest
Refer to the relevant section of
workshop manual. Reset
fuelling adaptions and carry out
Powertrain Control Module
(PCM) Long Drive Cycle Self-
Test
Check and install new mass air
flow sensor as required

P0102- Mass or Volume Fuse failure Check for fuse failure


00 Air Flow A Circuit Connector is disconnected, connector Inspect connectors for signs of
Low - No sub type terminal is backed out, connector water ingress, and pins for
information terminal corrosion damage and/or corrosion
Mass air flow sensor circuit, short Refer to the electrical circuit
circuit to ground, short circuit to diagrams and check mass air
power, open circuit, high resistance flow sensor circuit for short
Mass air flow sensor failure circuit to ground, short circuit
to power, open circuit, high
resistance
Clear the DTC and retest
Refer to the relevant section of
workshop manual. Reset
fuelling adaptions and carry out
Powertrain Control Module
(PCM) Long Drive Cycle Self-
Test
Check and install new mass air
flow sensor as required

P0103- Mass or Volume Connector is disconnected, connector Using the Jaguar Land Rover
00 Air Flow A Circuit terminal is backed out, connector approved diagnostic equipment
High - No sub type terminal corrosion check datalogger signal, Mass
information Mass air flow sensor circuit, short Air Flow Sensor, Bank 1
circuit to ground, short circuit to (0x0314)
power, open circuit, high resistance Inspect connectors for signs of
Blocked air cleaner element(s) water ingress, and pins for
Blockage in air intake system damage and/or corrosion
Mass air flow sensor failure Refer to the electrical circuit
diagrams and check mass air
flow sensor circuit for short
circuit to ground, short circuit
to power, open circuit, high
resistance
Check air cleaner element is
free from restriction and in
serviceable condition
Check air intake system for
blockage
Clear the DTC and retest
Refer to the relevant section of
workshop manual. Reset
fuelling adaptions and carry out
Powertrain Control Module
(PCM) Long Drive Cycle Self-
Test
Check and install new mass air
flow sensor as required

P0106- Manifold Absolute NOTE: Check air cleaner element is


00 Pressure/BARO free from restriction
Sensor - Circuit MAP_SENSOR - Check for leak from air intake
Range/Performance system, rectify as required
- No sub type Blocked air cleaner element(s) Refer to the electrical circuit
information Intake manifold air leak diagrams and check manifold
Manifold absolute pressure sensor absolute pressure sensor circuit
circuit short circuit to ground, short for short circuit to ground, short
circuit to power, open circuit, high circuit to power, open circuit,
resistance high resistance
Engine breather leak Ensure the engine breather
Carbon build up on throttle plate system is correctly installed and
Exhaust system blocked in serviceable condition
Manifold absolute pressure sensor Make sure throttle blade is
failure clean of carbon
BARO sensor failure Check for blocked exhaust
Check and install a new
manifold absolute pressure
sensor as required. Check for
related BARO sensor DTC
P0069-29. Refer to the
warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P0107- Manifold Absolute NOTE: Refer to the electrical circuit


00 Pressure/BARO diagrams and check manifold
Sensor Low - No - Circuit MAP_SENSOR - absolute pressure sensor circuit
sub type for short circuit to ground, open
information Manifold absolute pressure sensor circuit, high resistance
circuit short circuit to ground, open Check and install a new
circuit, high resistance manifold absolute pressure
Manifold absolute pressure sensor sensor as required. Refer to the
failure warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P0108- Manifold Absolute NOTE: Refer to the electrical circuit


00 Pressure/BARO diagrams and check manifold
Sensor High - No - Circuit MAP_SENSOR - absolute pressure sensor circuit
sub type for short circuit to power, open
information Manifold absolute pressure sensor circuit, high resistance
circuit short circuit to power, open Check and install a new
circuit, high resistance manifold absolute pressure
Manifold absolute pressure sensor sensor as required. Refer to the
failure warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P010B- Mass or Volume Intake air distribution and filtering Using the manufacturer
00 Air Flow B Circuit components incorrectly installed approved smoke tester check
Range/Performance Leakage from intake air system intake air distribution and
- No sub type Blocked air cleaner element(s) filtering components for
information Blocked engine breather leakage and correct installation
Blockage in intake air system Check air cleaner element is
Mass air flow sensor seal failure free from restriction and in
Connector is disconnected, connector serviceable condition
terminal is backed out, connector Ensure the engine breather
terminal corrosion system is correctly installed and
Mass air flow sensor circuit, short in serviceable condition
circuit to ground, short circuit to Check for mass air flow sensor
power, open circuit, high resistance seal integrity and correct
Carbon build-up on throttle blade installation
Blocked injectors Inspect connectors for signs of
Blocked catalysts water ingress, and pins for
Mass air flow sensor failure damage and/or corrosion
Refer to the electrical circuit
diagrams and check mass air
flow sensor circuit for short
circuit to ground, short circuit
to power, open circuit, high
resistance
Make sure throttle blade is
clean of carbon
Check for blocked injectors
Check for blocked catalysts
Clear the DTC and retest
Refer to the relevant section of
workshop manual. Reset
fuelling adaptions and carry out
Powertrain Control Module
(PCM) Long Drive Cycle Self-
Test
Check and install new mass air
flow sensor as required

P010C- Mass or Volume Fuse failure Check for fuse failure


00 Air Flow B Circuit Connector is disconnected, connector Inspect connectors for signs of
Low - No sub type terminal is backed out, connector water ingress, and pins for
information terminal corrosion damage and/or corrosion
Mass air flow sensor circuit, short Refer to the electrical circuit
circuit to ground, short circuit to diagrams and check mass air
power, open circuit, high resistance flow sensor circuit for short
Mass air flow sensor failure circuit to ground, short circuit
to power, open circuit, high
resistance
Clear the DTC and retest
Refer to the relevant section of
workshop manual. Reset
fuelling adaptions and carry out
Powertrain Control Module
(PCM) Long Drive Cycle Self-
Test
Check and install new mass air
flow sensor as required

P010D- Mass or Volume Connector is disconnected, connector Using the Jaguar Land Rover
00 Air Flow B Circuit terminal is backed out, connector approved diagnostic equipment
High - No sub type terminal corrosion check datalogger signal, Mass
information Mass air flow sensor circuit, short Air Flow Sensor 2 Voltage
circuit to ground, short circuit to (0x0503)
power, open circuit, high resistance Inspect connectors for signs of
Blocked air cleaner element(s) water ingress, and pins for
Blockage in air intake system damage and/or corrosion
Mass air flow sensor failure Refer to the electrical circuit
diagrams and check mass air
flow sensor circuit for short
circuit to ground, short circuit
to power, open circuit, high
resistance
Check air cleaner element is
free from restriction and in
serviceable condition
Check air intake system for
blockage
Clear the DTC and retest
Refer to the relevant section of
workshop manual. Reset
fuelling adaptions and carry out
Powertrain Control Module
(PCM) Long Drive Cycle Self-
Test
Check and install new mass air
flow sensor as required

P010F- Mass or Volume Intake air distribution and filtering Using the manufacturer
00 Air Flow Sensor components incorrectly installed approved smoke tester check
A/B Correlation - Leakage from intake air system intake air distribution and
No sub type Blocked air cleaner element(s) filtering components for
information Blocked engine breather leakage and correct installation
Blockage in intake air system Check air cleaner element is
Mass air flow sensor seal failure free from restriction and in
Connector is disconnected, connector serviceable condition
terminal is backed out, connector Ensure the engine breather
terminal corrosion system is correctly installed and
Mass air flow sensor circuit, short in serviceable condition
circuit to ground, short circuit to Check for mass air flow sensor
power, open circuit, high resistance seal integrity and correct
Carbon build-up on throttle blade installation
Blocked injectors Inspect connectors for signs of
Blocked catalysts water ingress, and pins for
Mass air flow sensor failure damage and/or corrosion
Refer to the electrical circuit
diagrams and check mass air
flow sensor circuit for short
circuit to ground, short circuit
to power, open circuit, high
resistance
Make sure throttle blade is
clean of carbon
Check for blocked injectors
Check for blocked catalysts
Clear the DTC and retest
Refer to the relevant section of
workshop manual. Reset
fuelling adaptions and carry out
Powertrain Control Module
(PCM) Long Drive Cycle Self-
Test
Check and install new mass air
flow sensor as required

P0111- Intake Air NOTE: Refer to the electrical circuit


23 Temperature diagrams and check intake air
Sensor 1 Circuit - Circuit INLET_AIR_TEMP_SENSOR_A - temperature sensor circuit for
Range/Performance short circuit to ground, open
- Signal stuck low Intake air temperature sensor short circuit, high resistance
circuit to ground, open circuit, high Check and install a new intake
resistance air temperature sensor as
Intake air temperature sensor failure required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0111- Intake Air NOTE: Refer to the electrical circuit


24 Temperature diagrams and check intake air
Sensor 1 Circuit - Circuit INLET_AIR_TEMP_SENSOR_A - temperature sensor circuit for
Range/Performance short circuit to power, open
- Signal stuck high Intake air temperature sensor circuit circuit
short circuit to power, open circuit Check and install a new intake
Intake air temperature sensor failure air temperature sensor as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0111- Intake Air NOTE: Refer to the electrical circuit


29 Temperature diagrams and check intake air
Sensor 1 Circuit - Circuit INLET_AIR_TEMP_SENSOR_A - temperature sensor circuit for
Range/Performance short circuit to ground, short
- Signal invalid Intake air temperature sensor circuit circuit to power, open circuit
short circuit to ground, short circuit to Check and install a new intake
power, open circuit air temperature sensor as
Intake air temperature sensor failure required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0112- Intake Air NOTE: Refer to the electrical circuit


00 Temperature diagrams and check intake air
Sensor 1 Circuit - Circuit INLET_AIR_TEMP_SENSOR_A - temperature sensor circuit for
Low (Bank 1) - No short circuit to ground, short
sub type Intake air temperature sensor circuit circuit to power, open circuit,
information short circuit to ground, short circuit to high resistance
power, open circuit, high resistance Check and install a new intake
Intake air temperature sensor failure air temperature sensor bank 1
as required. Refer to the
warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P0113- Intake Air NOTE: Refer to the electrical circuit


00 Temperature diagrams and check intake air
Sensor 1 Circuit - Circuit INLET_AIR_TEMP_SENSOR_A - temperature sensor circuit for
High (Bank 1) - No short circuit to power, open
sub type Intake air temperature sensor circuit circuit, high resistance
information short circuit to power, open circuit, Check and install a new intake
high resistance air temperature sensor bank 1
Intake air temperature sensor failure as required. Refer to the
warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P0116- Engine Coolant NOTE: Using the Jaguar Land Rover


23 Temperature approved diagnostic equipment
Sensor 1 Circuit - Circuit COOLANT_TEMP_SENSOR - check datalogger signal, Engine
Range/Performance Coolant Temperature Sensor
- Signal stuck low Battery reset carried out when the Voltage (0x0357)
engine was warm/hot Check for related DTC P2610-
Engine coolant temperature sensor 1 87. Start the engine and switch
sensing circuit intermittent high off. Clear DTC and re-test
resistance Refer to the electrical circuit
Engine coolant temperature sensor 1 diagrams and check engine
failure coolant temperature sensor 1
circuit for intermittent high
resistance
Check and install a new engine
coolant temperature sensor 1 as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0116- Engine Coolant NOTE: Using the Jaguar Land Rover


24 Temperature approved diagnostic equipment
Sensor 1 Circuit - Circuit COOLANT_TEMP_SENSOR - check datalogger signal, Engine
Range/Performance Coolant Temperature Sensor
- Signal stuck high Engine coolant temperature sensor 1 Voltage (0x0357)
sensing circuit intermittent high Check for related DTC P2610-
resistance 87. Start the engine and switch
Engine coolant temperature sensor 1 off. Clear DTC and re-test
failure Refer to the electrical circuit
Battery reset carried out when the diagrams and check engine
engine was warm/hot coolant temperature sensor 1
circuit for intermittent high
resistance
Check and install a new engine
coolant temperature sensor 1 as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0116- Engine Coolant NOTE: Fill cooling system to correct


29 Temperature level and specification
Sensor 1 Circuit - Circuit COOLANT_TEMP_SENSOR - Using the Jaguar Land Rover
Range/Performance approved diagnostic equipment
- Signal invalid Low coolant level check datalogger signal, Engine
Engine coolant temperature sensor 1 Coolant Temperature Sensor
sensing circuit - intermittent high Voltage (0x0357)
resistance Refer to the electrical circuit
Engine coolant temperature sensor 1 diagrams and check engine
failure coolant temperature sensor 1
Possible airlock in cooling system circuit for intermittent high
resistance
Check and install new engine
coolant temperature sensor 1 as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component
Bleed cooling system

P0117- Engine Coolant NOTE: Using the Jaguar Land Rover


16 Temperature approved diagnostic equipment
Sensor 1 Circuit - Circuit COOLANT_TEMP_SENSOR - check datalogger signal, Engine
Low - Circuit Coolant Temperature Sensor
voltage below Engine coolant temperature sensor 1 Voltage (0x0357)
threshold circuit short circuit to ground Refer to the electrical circuit
Engine coolant temperature sensor 1 diagrams and check engine
failure coolant temperature sensor 1
circuit for short circuit to
ground
Check and install a new Engine
coolant temperature sensor 1 as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0118- Engine Coolant NOTE: Using the Jaguar Land Rover


17 Temperature approved diagnostic equipment
Sensor 1 Circuit - Circuit COOLANT_TEMP_SENSOR - check datalogger signal, Engine
High - Circuit Coolant Temperature Sensor
voltage above Engine coolant temperature sensor 1 Voltage (0x0357)
threshold circuit short circuit to power, open Refer to the electrical circuit
circuit, sensor disconnected diagrams and check engine
Engine coolant temperature sensor 1 coolant temperature sensor 1
failure circuit for short circuit to
power, open circuit, sensor
disconnected
Check and install new engine
coolant temperature sensor 1 as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0121- Throttle/Pedal Corrupt engine control module Using the Jaguar Land Rover
00 Position Sensor A software flash approved diagnostic equipment
Circuit Engine control module power supply check and install latest relevant
Range/Performance circuit open circuit, high resistance level of software to the engine
- No sub type Engine control module damage control module
information through water ingress, internal fault Refer to the electrical circuit
diagrams and check engine
control module power supply
circuit for open circuit, high
resistance
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0122- Throttle/Pedal NOTE: Refer to the electrical circuit


00 Position Sensor A diagrams and check throttle
Circuit Low - No - Circuit position sensor 1 circuit for
sub type THROTTLE_POSITION_SENSOR_1 - short circuit to ground, open
information circuit
Throttle position sensor 1 circuit short Clear DTC and repeat
circuit to ground, open circuit automated diagnostic procedure
Throttle position sensor 1 failure using the Jaguar Land Rover
approved diagnostic equipment.
If DTC remains suspect the
electronic throttle unit
Check and install a new
electronic throttle unit as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0123- Throttle/Pedal NOTE: Refer to the electrical circuit


00 Position Sensor A diagrams and check throttle
Circuit High - No - Circuit position sensor 1 circuit for
sub type THROTTLE_POSITION_SENSOR_1 - short circuit to ground, short
information circuit to power, open circuit
Throttle position sensor 1 circuit short Clear DTC and repeat
circuit to ground, short circuit to automated diagnostic procedure
power, open circuit using the Jaguar Land Rover
Throttle position sensor 1 failure approved diagnostic equipment.
If DTC remains suspect the
electronic throttle unit
Check and install a new
electronic throttle unit as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0125- Insufficient Coolant temperature sensor 1 circuit, Refer to the electrical circuit
00 Coolant Temp For open circuit, high resistance diagrams and check engine
Closed Loop Fuel Engine coolant temperature sensor 1 coolant temperature sensor 1
Control - No sub failure circuit for open circuit, high
type information resistance
Check and install a new engine
coolant temperature sensor 1.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0126- Insufficient Thermostat stuck open Refer to the electrical circuit


26 Coolant Temp For Coolant temperature coolant sensor diagrams and check engine
Stable Operation - circuit, short circuit to ground, short coolant temperature sensor 1
Signal rate of circuit to power, open circuit circuit for short circuit to
change below ground, short circuit to power,
threshold open circuit
Check for related coolant
temperature coolant sensor
faults. Check and install a new
thermostat as required. Refer to
the warranty policy and
procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0128- Coolant Thermostat Thermostat stuck open Check for related coolant
00 (Coolant Temp Cooling fans running continuously or temperature coolant sensor
Below Thermostat at a high duty faults
Regulating Check cooling fans for correct
Temperature) - No operation. Repair as required
sub type Check and install a new
information thermostat as required. Refer to
the warranty policy and
procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0131- O2 Circuit Low Pre-catalyst oxygen sensor odd Check pre-catalyst oxygen
00 Voltage (Bank 1, disconnected sensor odd connector is
Sensor 1) - No sub Pre-catalyst oxygen sensor odd connected
type information variable circuit, short circuit to ground Refer to the electrical circuit
Pre-catalyst oxygen sensor odd diagrams and check pre-catalyst
variable circuit, open circuit oxygen sensor odd variable
Pre-catalyst oxygen sensor odd heater circuit for short circuit to
fault ground, open circuit
Pre-catalyst oxygen sensor odd failure Check pre-catalyst oxygen
sensor odd heater circuit
Check and install a new pre-
catalyst oxygen sensor odd as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0131- O2 Sensor Circuit NOTE: Check pre-catalyst oxygen


1A Low Voltage (Bank sensor odd connector is
1 Sensor 1) - - Circuit UHEGO_A_VARIABLE - connected
Circuit resistance Refer to the electrical circuit
below threshold Pre-catalyst oxygen sensor odd diagrams and check pre-catalyst
disconnected oxygen sensor odd variable
Pre-catalyst oxygen sensor odd circuit for short circuit to
variable circuit, short circuit to ground ground, open circuit
Pre-catalyst oxygen sensor odd Check pre-catalyst oxygen
variable circuit, open circuit sensor odd heater circuit
Pre-catalyst oxygen sensor odd heater Check and install a new pre-
fault catalyst oxygen sensor odd as
Pre-catalyst oxygen sensor odd failure required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0132- O2 Circuit High Pre-catalyst oxygen sensor odd Check pre-catalyst oxygen
00 Voltage (Bank 1, disconnected sensor odd connector is
Sensor 1) - No sub Pre-catalyst oxygen sensor odd connected
type information variable circuit, short circuit to power Refer to the electrical circuit
Pre-catalyst oxygen sensor odd diagrams and check pre-catalyst
variable circuit, open circuit oxygen sensor odd variable
Pre-catalyst oxygen sensor odd heater circuit for short circuit to
fault power, open circuit
Pre-catalyst oxygen sensor odd failure Check pre-catalyst oxygen
sensor odd heater circuit
Check and install a new pre-
catalyst oxygen sensor odd as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0132- O2 Sensor Circuit NOTE: Check pre-catalyst oxygen


1B High Voltage sensor odd connector is
(Bank 1 Sensor 1) - - Circuit UHEGO_A_VARIABLE - connected
Circuit resistance Refer to the electrical circuit
above threshold Pre-catalyst oxygen sensor odd diagrams and check pre-catalyst
disconnected oxygen sensor odd variable
Pre-catalyst oxygen sensor odd circuit for short circuit to
variable circuit, short circuit to power power, open circuit
Pre-catalyst oxygen sensor odd Check pre-catalyst oxygen
variable circuit, open circuit sensor odd heater circuit
Pre-catalyst oxygen sensor odd heater Check and install a new pre-
fault catalyst oxygen sensor odd as
Pre-catalyst oxygen sensor odd failure required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0133- O2 Circuit Slow NOTE: Check pre-catalyst oxygen


00 Response (Bank 1, sensor odd is correctly installed
Sensor 1) - No sub - Circuit UHEGO_A_VARIABLE - in exhaust manifold
type information Check for and rectify any
Exhaust leak exhaust leak between cylinder
Pre-catalyst oxygen sensor odd to head and catalytic converter
engine control module wiring shield Refer to the electrical circuit
high resistance diagrams and check pre-catalyst
Fuel control system fault oxygen sensor odd to engine
Pre-catalyst oxygen sensor odd failure control module wiring shield
for high resistance
Check fuel control system for
failure
Check and install a new pre-
catalyst oxygen sensor odd as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0134- O2 Circuit No NOTE: Refer to the electrical circuit


00 Activity Detected diagrams and check pre-catalyst
(Bank 1, Sensor 1) - Circuit UHEGO_A_VARIABLE - oxygen sensor odd circuit for
- No sub type short circuit to ground, short
information Pre-catalyst oxygen sensor odd circuit circuit to power, open circuit
short circuit to ground, short circuit to Check and install a new pre-
power, open circuit catalyst oxygen sensor odd as
Pre-catalyst oxygen sensor odd failure required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0137- O2 Circuit Low NOTE: Refer to the electrical circuit


00 Voltage (Bank 1, diagrams and check post
Sensor 2) - No sub - Circuit HEGO_SENSOR_A - catalyst oxygen sensor - odd,
type information sensing circuit for short circuit
Post catalyst oxygen sensor - odd, to ground, high resistance, open
sensing circuit short circuit to ground, circuit
high resistance, open circuit Check for damaged or blocked
Damaged or blocked catalyst catalyst
Air leak between catalyst and exhaust Check for air leak between
manifold catalyst and exhaust manifold
Post catalyst oxygen sensor - odd,
Check and install new post
failure catalyst oxygen sensor - odd, as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0138- O2 Circuit High NOTE: Refer to the electrical circuit


00 Voltage (Bank 1, diagrams and check post
Sensor 2) - No sub - Circuit HEGO_SENSOR_A - catalyst oxygen sensor - odd,
type information sensing circuit for short circuit
Post catalyst oxygen sensor - odd, to power
sensing circuit short circuit to power Check post catalyst oxygen
Post catalyst oxygen sensor - odd, tip sensor - odd, tip for damage,
damaged, blocked, poisoned blockage, poisoned, install a
Catalyst blocked new sensor as required
Post catalyst oxygen sensor - odd, Check for blocked catalyst
failure Check and install new catalyst
as required. Check and install
new post catalyst oxygen
sensor - odd, as required. Refer
to the warranty policy and
procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0139- O2 Circuit Slow NOTE: Check for excessive oil


00 Response (Bank 1, consumption. Repair as
Sensor 2) - No sub - Circuit HEGO_SENSOR_A - required
type information Check for related DTCs. Check
Excessive oil consumption post catalyst oxygen sensor -
Post catalyst oxygen sensor - odd, tip odd, tip for damage, blockage,
damaged, blocked, poisoned poisoned, install a new sensor
as required. Refer to the
warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P0140- O2 Circuit No NOTE: Refer to the electrical circuit


00 Activity Detected diagrams and check post
(Bank 1, Sensor 2) - Circuit HEGO_SENSOR_A - catalyst oxygen sensor - odd,
- No sub type sensing circuit for short circuit
information Post catalyst oxygen sensor - odd, to ground, short circuit to
sensing circuit short circuit to ground, power, high resistance, open
short circuit to power, high resistance, circuit
open circuit Check for air leak between
Air leak between catalyst and exhaust catalyst and exhaust manifold
manifold Check post catalyst oxygen
Post catalyst oxygen sensor - odd, tip sensor - odd, tip for damage,
damaged, blocked, poisoned blockage, poisoned, install a
Post catalyst oxygen sensor - odd, new sensor as required
failure Check for excessive oil
consumption. Repair as
required
Check and install new post
catalyst oxygen sensor - odd, as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0141- O2 Heater Circuit NOTE: Using the Jaguar Land Rover


00 (Bank 1, Sensor 2) approved diagnostic equipment
- No sub type - Circuit HTR_HEGO_A - check datalogger signal,
information Oxygen Sensor (O2S) Heater
Post catalyst oxygen sensor - odd, Duty Cycle Bank 1 Sensor 2
sensing circuit short circuit to ground, (0x03A2)
short circuit to power, high resistance, Refer to the electrical circuit
open circuit diagrams and check post
Air leak between catalyst and exhaust catalyst oxygen sensor - odd,
manifold sensing circuit for short circuit
Catalyst oxygen sensor heater circuit to ground, short circuit to
control relay failure power, high resistance, open
Post catalyst oxygen sensor - odd, circuit
failure Check for air leak between
catalyst and exhaust manifold
Refer to the electrical circuit
diagrams and check catalyst
oxygen sensor heater circuit
control relay circuit for short
circuit to ground, short circuit
to power, open circuit
Check and install a new catalyst
oxygen sensor heater control
relay, as required. Check and
install new post catalyst oxygen
sensor - odd, as required. Refer
to the warranty policy and
procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0148- Fuel Delivery Error Injector(s) circuit, short circuit to Check for related injector
65 - Signal has too few ground, short circuit to power, high DTCs
transitions / events resistance Refer to the electrical circuit
Injector(s) failure diagrams and check injector(s)
Engine control module internal failure circuit for, short circuit to
ground, short circuit to power,
high resistance
Check and install a new
injector(s) as required. Check
and install a new engine control
module as required. Refer to
the warranty policy and
procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0148- Fuel Delivery Error Injector(s) circuit, short circuit to Check for related injector
66 - Signal has too ground, short circuit to power, high DTCs
many transitions / resistance Refer to the electrical circuit
events Injector(s) failure diagrams and check injector(s)
Engine control module internal failure circuit for, short circuit to
ground, short circuit to power,
high resistance
Check and install a new
injector(s) as required. Check
and install a new engine control
module as required. Refer to
the warranty policy and
procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0149- Fuel Timing Error - Injector(s) circuit, short circuit to Check for related injector
32 Signal low time < ground, short circuit to power, high DTCs
minimum resistance Refer to the electrical circuit
Injector(s) failure diagrams and check injector(s)
Engine control module internal failure circuit for, short circuit to
ground, short circuit to power,
high resistance
Check and install a new
injector(s) as required. Check
and install a new engine control
module as required. Refer to
the warranty policy and
procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0149- Fuel Timing Error - Injector(s) circuit, short circuit to Check for related injector
35 Signal high time > ground, short circuit to power, high DTCs
maximum resistance Refer to the electrical circuit
Injector(s) failure diagrams and check injector(s)
Engine control module internal failure circuit for, short circuit to
ground, short circuit to power,
high resistance
Check and install a new
injector(s) as required. Check
and install a new engine control
module as required. Refer to
the warranty policy and
procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0151- O2 Sensor Circuit NOTE: Refer to the electrical circuit


1A Low Voltage (Bank diagrams and check pre-catalyst
2 Sensor 1) - - Circuit UHEGO_B_VARIABLE - oxygen sensor - even circuit for
Circuit resistance short circuit to ground
below threshold Pre-catalyst oxygen sensor - even Check and install new pre
circuit short circuit to ground catalyst oxygen sensor - even.
Pre-catalyst oxygen sensor - even Refer to the warranty policy
failure and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0152- O2 Sensor Circuit NOTE: Refer to the electrical circuit


1B Low Voltage (Bank diagrams and check pre-catalyst
2 Sensor 1) - - Circuit UHEGO_B_VARIABLE - oxygen sensor - even circuit for
Circuit resistance short circuit to power,
above threshold Pre-catalyst oxygen sensor - even disconnected
circuit short circuit to power, Check and install new pre
disconnected catalyst oxygen sensor - even.
Pre-catalyst oxygen sensor - even Refer to the warranty policy
failure and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0153- O2 Circuit Slow NOTE: Check pre-catalyst oxygen


00 Response (Bank 2, sensor even is correctly
Sensor 1) - No sub - Circuit UHEGO_B_VARIABLE - installed in exhaust manifold
type information Check for and rectify any
Exhaust leak exhaust leak between cylinder
Pre-catalyst oxygen sensor even to head and catalytic converter
engine control module wiring shield Refer to the electrical circuit
high resistance diagrams and check pre-catalyst
Pre-catalyst oxygen sensor even to oxygen sensor even to engine
engine control module signal circuit control module wiring shield
short circuit to ground for high resistance
Fuel control system fault Refer to the electrical circuit
Pre-catalyst oxygen sensor even failure diagrams and check Pre-
catalyst oxygen sensor even to
engine control module signal
circuit for short circuit to
ground
Check fuel control system for
failure
Check and install a new pre-
catalyst oxygen sensor even as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0154- O2 Circuit No NOTE: Check pre-catalyst oxygen


00 Activity Detected sensor even is correctly
(Bank 2, Sensor 1) - Circuit UHEGO_B_VARIABLE - installed in exhaust manifold
- No sub type Refer to the electrical circuit
information Pre-catalyst oxygen sensor even to diagrams and check pre-catalyst
engine control module wiring shield oxygen sensor even to engine
high resistance control module wiring shield
Pre-catalyst oxygen sensor even to for high resistance
engine control module signal circuit Refer to the electrical circuit
short circuit to ground, high resistance, diagrams and check pre-catalyst
open circuit oxygen sensor even to engine
Pre-catalyst oxygen sensor even failure control module signal circuit
for short circuit to ground, high
resistance, open circuit
Check and install a new pre-
catalyst oxygen sensor even as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0157- O2 Circuit Low NOTE: Refer to the electrical circuit


00 Voltage (Bank 2, diagrams and check post
Sensor 2) - No sub - Circuit HEGO_SENSOR_B - catalyst oxygen sensor - even,
type information sensing circuit for short circuit
Post catalyst oxygen sensor - even, to ground, high resistance, open
sensing circuit short circuit to ground, circuit
high resistance, open circuit Check for air leak between
Air leak between catalyst and exhaust catalyst and exhaust manifold
manifold Check post catalyst oxygen
Post catalyst oxygen sensor - even, tip sensor - even, tip for damage,
damaged, blocked, poisoned blockage, poisoned
Post catalyst oxygen sensor - even, Check and install new post
failure catalyst oxygen sensor - even,
as required. Refer to the
warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P0158- O2 Circuit High NOTE: Refer to the electrical circuit


00 Voltage (Bank 2, diagrams and check post
Sensor 2) - No sub - Circuit HEGO_SENSOR_B - catalyst oxygen sensor - even,
type information sensing circuit for short circuit
Post catalyst oxygen sensor - even, to power
sensing circuit short circuit to power Check post catalyst oxygen
Post catalyst oxygen sensor - even, tip sensor - even, tip for damage,
damaged, blocked, poisoned blockage, poisoned
Post catalyst oxygen sensor - even, Check and install new post
failure catalyst oxygen sensor - even,
as required. Refer to the
warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P0159- O2 Circuit Slow NOTE: Check for excessive oil


00 Response (Bank 2, consumption, repair as required
Sensor 2) - No sub - Circuit HEGO_SENSOR_B - Check post catalyst oxygen
type information sensor - even, tip for damage,
Excessive oil consumption blockage, poisoned, install a
Post catalyst oxygen sensor - even, tip new sensor as required. Refer
damaged, blocked, poisoned to the warranty policy and
Post catalyst oxygen sensor - even, procedures manual, or
failure determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0160- O2 Circuit No NOTE: Refer to the electrical circuit


00 Activity Detected diagrams and check post
(Bank 2, Sensor 2) - Circuit HEGO_SENSOR_B - catalyst oxygen sensor - even,
- No sub type sensing circuit for short circuit
information Post catalyst oxygen sensor - even, to ground, short circuit to
sensing circuit short circuit to ground, power, high resistance, open
short circuit to power, high resistance, circuit
open circuit Check for air leak between
Air leak between catalyst and exhaust catalyst and exhaust manifold
manifold Check post catalyst oxygen
Post catalyst oxygen sensor - even, tip sensor - even, tip for damage,
damaged, blocked, poisoned blockage, poisoned
Post catalyst oxygen sensor - even, Check and install new post
failure catalyst oxygen sensor - even,
as required. Refer to the
warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P0161- O2 Heater Circuit NOTE: Refer to the electrical circuit


00 (Bank 2, Sensor 2) diagrams and check post
- No sub type - Circuit HTR_HEGO_B - catalyst oxygen sensor - even,
information sensing circuit for short circuit
Post catalyst oxygen sensor - even, to ground, short circuit to
sensing circuit short circuit to ground, power, high resistance, open
short circuit to power, high resistance, circuit
open circuit Refer to the electrical circuit
Post catalyst oxygen sensor - even, diagrams and check Post
sensing circuit fuse failure catalyst oxygen sensor - even,
Catalyst oxygen sensor heater circuit
sensing circuit fuse, replace as
control relay failure required
Post catalyst oxygen sensor - even, Refer to the electrical circuit
failure diagrams and check catalyst
oxygen sensor heater circuit
control relay circuit for short
circuit to ground, short circuit
to power, open circuit
Check and install a new catalyst
oxygen sensor heater control
relay, as required. Check and
install new post catalyst oxygen
sensor - even, as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0171- System Too Lean Air leak upstream of MAF/IAT sensor Refer to the electrical circuit
00 (Bank 1) - No sub bank 1 diagrams and check MAF/IAT
type information MAF/IAT sensor bank 1 circuit failure sensor circuit, for short circuit
MAF/IAT sensor bank 1 failure to ground, short circuit power,
Pre-catalyst oxygen sensor odd circuit high resistance, open circuit
failure Refer to the electrical circuit
Pre-catalyst oxygen sensor odd failure diagrams and check post
Post-catalyst oxygen sensor odd circuit catalyst oxygen sensor - even,
failure sensing circuit for short circuit
Post-catalyst oxygen sensor odd failure to ground, short circuit power,
high resistance, open circuit
Check for leak from air intake
system
Check for additional MAF/IAT
sensor bank 1 related DTCs and
refer to relevant DTC index
Check for additional pre-
catalyst oxygen sensor odd
related DTCs and refer to
relevant DTC index
Check for additional post-
catalyst oxygen sensor odd
related DTCs and refer to
relevant DTC index

P0172- System Too Rich Restricted air cleaner Refer to the electrical circuit
00 (Bank 1) - No sub Leaking fuel injector(s) diagrams and check MAF/IAT
type information MAF/IAT sensor bank 1 failure sensor circuit, for short circuit
Pre-catalyst oxygen sensor odd circuit to ground, short circuit power,
failure high resistance, open circuit
Pre-catalyst oxygen sensor odd failure Refer to the electrical circuit
Post-catalyst oxygen sensor odd circuit diagrams and check post
failure catalyst oxygen sensor - even,
Post-catalyst oxygen sensor odd failure sensing circuit for short circuit
to ground, short circuit power,
high resistance, open circuit
Check air cleaner element is
free from restriction
Check for leaking injectors,
install new injector(s) as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component
Check for additional MAF/IAT
sensor bank 1 related DTCs and
refer to relevant DTC index
Check for additional pre-
catalyst oxygen sensor odd
related DTCs and refer to
relevant DTC index
Check for additional post-
catalyst oxygen sensor odd
related DTCs and refer to
relevant DTC index

P0174- System Too Lean Air leak upstream of MAF/IAT sensor Refer to the electrical circuit
00 (Bank 2) - No sub bank 2 diagrams and check MAF/IAT
type information MAF/IAT sensor bank 2 circuit failure sensor circuit, for short circuit
MAF/IAT sensor bank 2 failure to ground, short circuit power,
Pre-catalyst oxygen sensor even circuit high resistance, open circuit
failure Refer to the electrical circuit
Pre-catalyst oxygen sensor even failure diagrams and check post
Post-catalyst oxygen sensor even catalyst oxygen sensor - even,
circuit failure sensing circuit for short circuit
Post-catalyst oxygen sensor even to ground, short circuit power,
failure high resistance, open circuit
Check for leak from air intake
system
Check for additional MAF/IAT
sensor bank 2 related DTCs and
refer to relevant DTC index
Check for additional pre-
catalyst oxygen sensor even
related DTCs and refer to
relevant DTC index
Check for additional post-
catalyst oxygen sensor even
related DTCs and refer to
relevant DTC index

P0175- System Too Rich Restricted air cleaner Refer to the electrical circuit
00 (Bank 2) - No sub Leaking fuel injector(s) diagrams and check MAF/IAT
type information MAF/IAT sensor bank 2 circuit failure sensor circuit, for short circuit
MAF/IAT sensor bank 2 failure to ground, short circuit power,
Pre-catalyst oxygen sensor even circuit high resistance, open circuit
failure Refer to the electrical circuit
Pre-catalyst oxygen sensor even failure diagrams and check post
Post-catalyst oxygen sensor even catalyst oxygen sensor - even,
circuit failure sensing circuit for short circuit
Post-catalyst oxygen sensor even to ground, short circuit power,
failure high resistance, open circuit
Check for leak from air intake
system
Check for additional MAF/IAT
sensor bank 2 related DTCs and
refer to relevant DTC index
Check for additional pre-
catalyst oxygen sensor even
related DTCs and refer to
relevant DTC index
Check for additional post-
catalyst oxygen sensor even
related DTCs and refer to
relevant DTC index

P018B- Fuel Pressure NOTE: Using the Jaguar Land Rover


29 Sensor B Circuit approved diagnostic equipment
Range/Performance - Circuit check datalogger signal, Fuel
- Signal invalid LOW_PRESS_FUEL_PRESS_SENSOR - Rail Pressure - Low Range
Sensor Voltage (0x0376)
Fuel Filter or fuel system restriction Check for related fuel pump
Fuel system leak DTCs
Fuel pump pressure sensor circuit short Check the fuel system for
circuit to ground, short circuit to restrictions or blockages
power, open circuit, high resistance Refer to the electrical circuit
Fuel pump pressure sensor failure diagrams and check fuel pump
pressure sensor circuit for short
circuit to power, open circuit,
high resistance
Check and install a new fuel
pump pressure sensor as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P018C- Fuel Pressure NOTE: Using the Jaguar Land Rover


00 Sensor B Circuit approved diagnostic equipment
Low - No sub type - Circuit check datalogger signal, Fuel
information LOW_PRESS_FUEL_PRESS_SENSOR - Rail Pressure - Low Range
Sensor Voltage (0x0376)
Fuel pump pressure sensor circuit short Refer to the electrical circuit
circuit to ground, short circuit to diagrams and check fuel pump
power, open circuit, high resistance pressure sensor circuit for short
Fuel pump pressure sensor failure circuit to power, short circuit to
ground, open circuit, high
resistance
Check and install a new fuel
pump pressure sensor as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P018D- Fuel Pressure NOTE: Using the Jaguar Land Rover


00 Sensor B Circuit approved diagnostic equipment
High - No sub type - Circuit check datalogger signal, Fuel
information LOW_PRESS_FUEL_PRESS_SENSOR - Rail Pressure - Low Range
Sensor Voltage (0x0376)
Fuel pump pressure sensor circuit short Refer to the electrical circuit
circuit to ground, short circuit to diagrams and check fuel pump
power, open circuit, high resistance pressure sensor circuit for short
Fuel pump pressure sensor failure circuit to power, short circuit to
ground, open circuit, high
resistance
Check and install a new fuel
pump pressure sensor as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0191- Fuel Rail Pressure NOTE: Using the Jaguar Land Rover
00 Sensor A Circuit approved diagnostic equipment
Range/Performance - Circuit FUEL_HIGH_PRESS_SENSOR - check datalogger signal, Fuel
- No sub type Rail Pressure Sensor - High
information Fuel rail pressure sensor short circuit Range Sensor Voltage (0x0377)
to ground, short circuit to power, open Refer to the electrical circuit
circuit, high resistance diagrams and check fuel rail
Fuel rail pressure sensor A failure pressure sensor A circuit for
short circuit to power, short
circuit to ground, high
resistance, open circuit,
terminal damage or corrosion
Check and install a new fuel
rail pressure sensor A as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0192- Fuel Rail Pressure NOTE: Using the Jaguar Land Rover
00 Sensor A Circuit approved diagnostic equipment
Low - No sub type - Circuit FUEL_HIGH_PRESS_SENSOR - check datalogger signal, Fuel
information Rail Pressure Sensor - High
Fuel rail pressure sensor short circuit Range Sensor Voltage (0x0377)
to ground, short circuit to power, open Refer to the electrical circuit
circuit, high resistance diagrams and check fuel rail
Fuel rail pressure sensor A failure pressure sensor A circuit for
short circuit to power, short
circuit to ground, high
resistance, open circuit,
terminal damage or corrosion
Check and install a new fuel
rail pressure sensor A as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0193- Fuel Rail Pressure NOTE: Using the Jaguar Land Rover
00 Sensor A Circuit approved diagnostic equipment
High - No sub type - Circuit FUEL_HIGH_PRESS_SENSOR - check datalogger signal, Fuel
information Rail Pressure Sensor - High
Fuel rail pressure sensor short circuit Range Sensor Voltage (0x0377)
to ground, short circuit to power, open Refer to the electrical circuit
circuit, high resistance diagrams and check fuel rail
Fuel rail pressure sensor A failure pressure sensor A circuit for
short circuit to power, short
circuit to ground, high
resistance, open circuit,
terminal damage or corrosion
Check and install a new fuel
rail pressure sensor A as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0196- Engine Oil NOTE: Using the Jaguar Land Rover


23 Temperature approved diagnostic equipment
Sensor - Circuit OIL_QUALITY_SENSOR - check datalogger signal, Sump
Range/Performance Oil Temperature - Measured
- Signal stuck low Oil temperature - level sensor circuit (0x03F3)
short circuit to ground, high resistance Refer to the electrical circuit
Oil temperature - level sensor failure diagrams and check oil
temperature - level sensor
circuit for short circuit to
ground, intermittent high
resistance
Check and install new oil
temperature - level sensor as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0196- Engine Oil NOTE: Using the Jaguar Land Rover


24 Temperature approved diagnostic equipment
Sensor - Circuit OIL_QUALITY_SENSOR - check datalogger signal, Sump
Range/Performance Oil Temperature - Measured
- Signal stuck high Oil temperature - level sensor circuit (0x03F3)
short circuit to power Refer to the electrical circuit
Oil temperature - level sensor failure diagrams and check oil
temperature - level sensor
circuit for intermittent short
circuit to power
Check and install new oil
temperature - level sensor as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0200- Injector Circuit - Engine control module injector circuit Refer to the electrical circuit
04 System internal power failure diagrams and check engine
failures Engine control module power supply control module injector power
open circuit circuit for open circuit
Engine control module ground supply Refer to the electrical circuit
open circuit diagrams and check the power
and ground connections to the
module
Check for misfire DTCs, if
present suspect the engine
control module

P0200- Injector Circuit - Engine control module failure Check for misfire DTCs, if
49 Internal electronic present suspect the engine
failure control module
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0200- Injector Circuit - Engine control module failure If combined with misfire codes
4B Over temperature for one or both injector sets,
then no service rectification is
proposed
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0201- Cylinder 1 Injector NOTE: Refer to the electrical circuit


13 Circuit / Open - diagrams and check fuel
- Circuit INJECTOR_1A -
Circuit open injector no.1 circuit for open
INJECTOR_1A_COMMON - circuit, disconnected injector,
high resistance
Fuel injector no.1 circuit open circuit
Injector disconnected
Injector high resistance

P0202- Cylinder 2 Injector NOTE: Refer to the electrical circuit


13 Circuit / Open - diagrams and check fuel
Circuit open - Circuit INJECTOR_1B - injector no.2 circuit for open
INJECTOR_1B_COMMON - circuit, disconnected injector,
high resistance
Fuel injector no.2 circuit open circuit
Injector disconnected
Injector high resistance

P0203- Cylinder 3 Injector NOTE: Refer to the electrical circuit


13 Circuit / Open - diagrams and check fuel
Circuit open - Circuit INJECTOR_2A - injector no.3 circuit for open
INJECTOR_2A_COMMON - circuit, disconnected injector,
high resistance
Fuel injector no.3 circuit open circuit
Injector disconnected
Injector high resistance

P0204- Cylinder 4 Injector NOTE: Refer to the electrical circuit


13 Circuit / Open - diagrams and check fuel
Circuit open - Circuit INJECTOR_2B - injector no.4 circuit for open
INJECTOR_2B_COMMON - circuit, disconnected injector,
high resistance
Fuel injector no.4 circuit open circuit
Injector disconnected
Injector high resistance

P0205- Cylinder 5 Injector NOTE: Refer to the electrical circuit


13 Circuit / Open - diagrams and check fuel
Circuit open - Circuit INJECTOR_3A - injector no.5 circuit for open
INJECTOR_3A_COMMON - circuit, disconnected injector,
high resistance
Fuel injector no.5 circuit open circuit
Injector disconnected
Injector high resistance

P0206- Cylinder 6 Injector NOTE: Refer to the electrical circuit


13 Circuit / Open - diagrams and check fuel
Circuit open - Circuit INJECTOR_3B - injector no.6 circuit for open
INJECTOR_3B_COMMON - circuit, disconnected injector,
high resistance
Fuel injector no.6 circuit open circuit
Injector disconnected
Injector high resistance

P0207- Cylinder 7 Injector NOTE: Refer to the electrical circuit


13 Circuit / Open - diagrams and check fuel
Circuit open - Circuit INJECTOR_4A - injector no.7 circuit for open
INJECTOR_4A_COMMON - circuit, disconnected injector,
high resistance
Fuel injector no.7 circuit open circuit
Injector disconnected
Injector high resistance

P0208- Cylinder 8 Injector NOTE: Refer to the electrical circuit


13 Circuit / Open - diagrams and check fuel
Circuit open - Circuit INJECTOR_4B - injector no.8 circuit for open
INJECTOR_4B_COMMON - circuit, disconnected injector,
high resistance
Fuel injector no.8 circuit open circuit
Injector disconnected
Injector high resistance

P0222- Throttle/Pedal NOTE: Refer to the electrical circuit


00 Position diagrams and check
Sensor/Switch B - Circuit throttle/pedal position
Circuit Low - No THROTTLE_POSITION_SENSOR_2 - sensor/switch B circuit for open
sub type circuit, short circuit to ground
information Throttle/pedal position sensor/switch B Check and install a new
circuit open circuit, short circuit to throttle/pedal position
ground sensor/switch B as required.
Throttle/pedal position sensor/switch B Refer to the warranty policy
failure and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0223- Throttle/Pedal NOTE: Refer to the electrical circuit


00 Position diagrams and check
Sensor/Switch B - Circuit throttle/pedal position
Circuit High - No THROTTLE_POSITION_SENSOR_2 - sensor/switch B circuit for open
sub type circuit, short circuit to power
information Throttle/pedal position sensor/switch B Check and install a new
circuit open circuit, short circuit to throttle/pedal position
power sensor/switch B as required.
Throttle/pedal position sensor/switch B Refer to the warranty policy
failure and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0231- Fuel Pump NOTE: Check for related DTCs P0232-


23 Secondary Circuit 24
Low - Signal stuck - Circuit Refer to the electrical circuit
low HIGH_PRESS_FUEL_PUMP_CTRL_2NEG diagrams and check fuel pump
- driver module signal circuit for
HIGH_PRESS_FUEL_PUMP_CTRL_2POS short circuit to ground, open
- circuit
Refer to the electrical circuit
Fuel pump driver module signal circuit diagrams and check fuel pump
short circuit to ground, open circuit driver module is energized with
Fuel pump driver module is not the ignition on. Repair as
energized with the ignition on required
Fuel pump driver module failure Using the Jaguar Land Rover
approved diagnostic equipment,
perform routine - Inline
diagnostic unit 2 non-intrusive
test - Low pressure fuel pump
Check and install a new fuel
pump driver module as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0232- Fuel Pump NOTE: Check for related DTCs P0231-


24 Secondary Circuit 23
Low - Signal stuck - Circuit Refer to the electrical circuit
high HIGH_PRESS_FUEL_PUMP_CTRL_2NEG diagrams and check fuel pump
- driver module signal circuit for
HIGH_PRESS_FUEL_PUMP_CTRL_2POS short circuit to ground, open
- circuit
Refer to the electrical circuit
Fuel pump driver module signal circuit diagrams and check fuel pump
short circuit to ground, open circuit driver module is energized with
Fuel pump driver module is not the ignition on. Repair as
energized with the ignition on required
Fuel pump driver module failure Using the Jaguar Land Rover
approved diagnostic equipment,
perform routine - Inline
diagnostic unit 2 non-intrusive
test - Low pressure fuel pump
Check and install a new fuel
pump driver module as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0251- Injection Pump NOTE: Refer to the electrical circuit


13 Fuel Metering diagrams and check fuel rail
Control A - Circuit - Circuit pressure sensor circuit for open
open HIGH_PRESS_FUEL_PUMP_CTRL_1NEG circuit
-
HIGH_PRESS_FUEL_PUMP_CTRL_2NEG
-

Fuel rail pressure sensor circuit, open


circuit

P0253- Injection Pump NOTE: Refer to the electrical circuit


11 Fuel Metering diagrams and check fuel rail
Control A Low - - Circuit pressure sensor circuit for short
Circuit short to HIGH_PRESS_FUEL_PUMP_CTRL_1NEG circuit to ground
ground -
HIGH_PRESS_FUEL_PUMP_CTRL_2NEG
-
Fuel rail pressure sensor circuit, short
circuit to ground

P0254- Injection Pump NOTE: Refer to the electrical circuit


12 Fuel Metering diagrams and check fuel rail
Control A High - - Circuit pressure sensor circuit for short
Circuit short to HIGH_PRESS_FUEL_PUMP_CTRL_1NEG circuit to power
battery -
HIGH_PRESS_FUEL_PUMP_CTRL_2NEG
-

Fuel rail pressure sensor circuit, short


circuit to power

P0256- Injection Pump NOTE: Refer to the electrical circuit


13 Fuel Metering diagrams and check fuel rail
Control B - Circuit - Circuit pressure sensor circuit for open
open HIGH_PRESS_FUEL_PUMP_CTRL_1NEG circuit
-
HIGH_PRESS_FUEL_PUMP_CTRL_2NEG
-

Fuel rail pressure sensor circuit, open


circuit

P0258- Injection Pump NOTE: Refer to the electrical circuit


11 Fuel Metering diagrams and check fuel rail
Control B Low - - Circuit pressure sensor circuit for short
Circuit short to HIGH_PRESS_FUEL_PUMP_CTRL_1NEG circuit to ground
ground -
HIGH_PRESS_FUEL_PUMP_CTRL_2NEG
-

Fuel rail pressure sensor circuit, short


circuit to ground

P0259- Injection Pump NOTE: Refer to the electrical circuit


12 Fuel Metering diagrams and check fuel rail
Control B High - - Circuit pressure sensor circuit for short
Circuit short to HIGH_PRESS_FUEL_PUMP_CTRL_1NEG circuit to power
battery -
HIGH_PRESS_FUEL_PUMP_CTRL_2NEG
-

Fuel rail pressure sensor circuit, short


circuit to power

P025C- Fuel Pump Module NOTE: Refer to the electrical circuit


14 Control Circuit diagrams and check fuel pump
Low - Circuit short - Circuit FPDM control - driver module circuit short
to ground or open circuit to ground, open circuit
Fuel pump driver module control Using the Jaguar Land Rover
circuit, short circuit to ground, open approved diagnostic equipment,
circuit perform routine - Inline
diagnostic unit 2 non-intrusive
test - Low pressure fuel pump
P025D- Fuel Pump Module NOTE: Refer to the electrical circuit
12 Control Circuit diagrams and check fuel pump
High - Circuit short - Circuit FPDM control - driver module circuit short
to battery circuit to power
Fuel pump driver module control Using the Jaguar Land Rover
circuit, short circuit to power approved diagnostic equipment,
perform routine - Inline
diagnostic unit 2 non-intrusive
test - Low pressure fuel pump

P0261- Cylinder 1 Injector NOTE: Refer to the electrical circuit


11 Circuit Low - diagrams and check fuel
Circuit short to - Circuit INJECTOR_1A - injector no.1 circuit for short
ground INJECTOR_1A_COMMON - circuit to ground

Fuel injector no.1 circuit short circuit


to ground

P0261- Cylinder 1 Injector NOTE: Refer to the electrical circuit


12 Circuit Low - diagrams and check fuel
Circuit short to - Circuit INJECTOR_1A - injector no.1 circuit for short
battery INJECTOR_1A_COMMON - circuit to power

Fuel injector no.1 circuit short circuit


to power

P0262- Cylinder 1 Injector NOTE: Refer to the electrical circuit


01 Circuit High - diagrams and check fuel
General electrical - Circuit INJECTOR_1A - injector no.1 circuit for short
failure INJECTOR_1A_COMMON - circuit to ground, short circuit
to power
Fuel injector no.1 circuit short circuit
to ground, short circuit to power

P0262- Cylinder 1 Injector NOTE: Refer to the electrical circuit


12 Circuit High - diagrams and check fuel
Circuit short to - Circuit INJECTOR_1A - injector no.1 circuit for short
battery INJECTOR_1A_COMMON - circuit to power

Fuel injector no.1 circuit short circuit


to power

P0264- Cylinder 2 Injector NOTE: Refer to the electrical circuit


11 Circuit Low - diagrams and check fuel
Circuit short to - Circuit INJECTOR_1B - injector no.2 circuit for short
ground INJECTOR_1B_COMMON - circuit to ground

Fuel injector no.2 circuit short circuit


to ground

P0264- Cylinder 2 Injector NOTE: Refer to the electrical circuit


12 Circuit Low - diagrams and check fuel
Circuit short to - Circuit INJECTOR_1B - injector no.2 circuit for short
battery INJECTOR_1B_COMMON - circuit to power

Fuel injector no.2 circuit short circuit


to power
P0265- Cylinder 2 Injector NOTE: Refer to the electrical circuit
01 Circuit High - diagrams and check fuel
General electrical - Circuit INJECTOR_1B - injector no.2 circuit for short
failure INJECTOR_1B_COMMON - circuit to ground, short circuit
to power
Fuel injector no.2 circuit short circuit
to ground, short circuit to power

P0265- Cylinder 2 Injector NOTE: Refer to the electrical circuit


12 Circuit High - diagrams and check fuel
Circuit short to - Circuit INJECTOR_1B - injector no.2 circuit for short
battery INJECTOR_1B_COMMON - circuit to power

Fuel injector no.2 circuit short circuit


to power

P0267- Cylinder 3 Injector NOTE: Refer to the electrical circuit


11 Circuit Low - diagrams and check fuel
Circuit short to - Circuit INJECTOR_2A - injector no.3 circuit for short
ground INJECTOR_2A_COMMON - circuit to ground

Fuel injector no.3 circuit short circuit


to ground

P0267- Cylinder 3 Injector NOTE: Refer to the electrical circuit


12 Circuit Low - diagrams and check fuel
Circuit short to - Circuit INJECTOR_2A - injector no.3 circuit for short
battery INJECTOR_2A_COMMON - circuit to power

Fuel injector no.3 circuit short circuit


to power

P0268- Cylinder 3 Injector NOTE: Refer to the electrical circuit


01 Circuit High - diagrams and check fuel
General electrical - Circuit INJECTOR_2A - injector no.3 circuit for short
failure INJECTOR_2A_COMMON - circuit to ground, short circuit
to power
Fuel injector no.3 circuit short circuit
to ground, short circuit to power

P0268- Cylinder 3 Injector NOTE: Refer to the electrical circuit


12 Circuit High - diagrams and check fuel
Circuit short to - Circuit INJECTOR_2A - injector no.3 circuit for short
battery INJECTOR_2A_COMMON - circuit to power

Fuel injector no.3 circuit short circuit


to power

P0270- Cylinder 4 Injector NOTE: Refer to the electrical circuit


11 Circuit Low - diagrams and check fuel
Circuit short to - Circuit INJECTOR_2B - injector no.4 circuit for short
ground INJECTOR_2B_COMMON - circuit to ground

Fuel injector no.4 circuit short circuit


to ground

P0270- Cylinder 4 Injector NOTE: Refer to the electrical circuit


12 Circuit Low - diagrams and check fuel
Circuit short to - Circuit INJECTOR_2B - injector no.4 circuit for short
battery INJECTOR_2B_COMMON - circuit to power

Fuel injector no.4 circuit short circuit


to power

P0271- Cylinder 4 Injector NOTE: Refer to the electrical circuit


01 Circuit High - diagrams and check fuel
General electrical - Circuit INJECTOR_2B - injector no.4 circuit for short
failure INJECTOR_2B_COMMON - circuit to ground, short circuit
to power
Fuel injector no.4 circuit short circuit
to ground, short circuit to power

P0271- Cylinder 4 Injector NOTE: Refer to the electrical circuit


12 Circuit High - diagrams and check fuel
Circuit short to - Circuit INJECTOR_2B - injector no.4 circuit for short
battery INJECTOR_2B_COMMON - circuit to power

Fuel injector no.4 circuit short circuit


to power

P0273- Cylinder 5 Injector NOTE: Refer to the electrical circuit


11 Circuit Low - diagrams and check fuel
Circuit short to - Circuit INJECTOR_3A - injector no.5 circuit for short
ground INJECTOR_3A_COMMON - circuit to ground

Fuel injector no.5 circuit short circuit


to ground

P0273- Cylinder 5 Injector NOTE: Refer to the electrical circuit


12 Circuit Low - diagrams and check fuel
Circuit short to - Circuit INJECTOR_3A - injector no.5 circuit for short
battery INJECTOR_3A_COMMON - circuit to power

Fuel injector no.5 circuit short circuit


to power

P0274- Cylinder 5 Injector NOTE: Refer to the electrical circuit


01 Circuit High - diagrams and check fuel
General electrical - Circuit INJECTOR_3A - injector no.5 circuit for short
failure INJECTOR_3A_COMMON - circuit to ground, short circuit
to power
Fuel injector no.5 circuit short circuit
to ground, short circuit to power

P0274- Cylinder 5 Injector NOTE: Refer to the electrical circuit


12 Circuit High - diagrams and check fuel
Circuit short to - Circuit INJECTOR_3A - injector no.5 circuit for short
battery INJECTOR_3A_COMMON - circuit to power

Fuel injector no.5 circuit short circuit


to power

P0276- Cylinder 6 Injector NOTE: Refer to the electrical circuit


11 Circuit Low - diagrams and check fuel
Circuit short to - Circuit INJECTOR_3B - injector no.6 circuit for short
ground INJECTOR_3B_COMMON - circuit to ground

Fuel injector no.6 circuit short circuit


to ground

P0276- Cylinder 6 Injector NOTE: Refer to the electrical circuit


12 Circuit Low - diagrams and check fuel
Circuit short to - Circuit INJECTOR_3B - injector no.6 circuit for short
battery INJECTOR_3B_COMMON - circuit to power

Fuel injector no.6 circuit short circuit


to power

P0277- Cylinder 6 Injector NOTE: Refer to the electrical circuit


01 Circuit High - diagrams and check fuel
General electrical - Circuit INJECTOR_3B - injector no.6 circuit for short
failure INJECTOR_3B_COMMON - circuit to ground, short circuit
to power
Fuel injector no.6 circuit short circuit
to ground, short circuit to power

P0277- Cylinder 6 Injector NOTE: Refer to the electrical circuit


12 Circuit High - diagrams and check fuel
Circuit short to - Circuit INJECTOR_3B - injector no.6 circuit for short
battery INJECTOR_3B_COMMON - circuit to power

Fuel injector no.6 circuit short circuit


to power

P0279- Cylinder 7 Injector NOTE: Refer to the electrical circuit


11 Circuit Low - diagrams and check fuel
Circuit short to - Circuit INJECTOR_4A - injector no.7 circuit for short
ground INJECTOR_4A_COMMON - circuit to ground

Fuel injector no.7 circuit short circuit


to ground

P0279- Cylinder 7 Injector NOTE: Refer to the electrical circuit


12 Circuit Low - diagrams and check fuel
Circuit short to - Circuit INJECTOR_4A - injector no.7 circuit for short
battery INJECTOR_4A_COMMON - circuit to power

Fuel injector no.7 circuit short circuit


to power

P0280- Cylinder 7 Injector NOTE: Refer to the electrical circuit


01 Circuit High - diagrams and check fuel
General electrical - Circuit INJECTOR_4A - injector no.7 circuit for short
failure INJECTOR_4A_COMMON - circuit to ground, short circuit
to power
Fuel injector no.7 circuit short circuit
to ground, short circuit to power

P0280- Cylinder 7 Injector NOTE: Refer to the electrical circuit


12 Circuit High - diagrams and check fuel
Circuit short to - Circuit INJECTOR_4A - injector no.7 circuit for short
battery INJECTOR_4A_COMMON - circuit to power

Fuel injector no.7 circuit short circuit


to power

P0282- Cylinder 8 Injector NOTE: Refer to the electrical circuit


11 Circuit Low - diagrams and check fuel
Circuit short to - Circuit INJECTOR_4B - injector no.8 circuit for short
ground INJECTOR_4B_COMMON - circuit to ground

Fuel injector no.8 circuit short circuit


to ground

P0282- Cylinder 8 Injector NOTE: Refer to the electrical circuit


12 Circuit Low - diagrams and check fuel
Circuit short to - Circuit INJECTOR_4B - injector no.8 circuit for short
battery INJECTOR_4B_COMMON - circuit to power

Fuel injector no.8 circuit short circuit


to power

P0283- Cylinder 8 Injector NOTE: Refer to the electrical circuit


01 Circuit High - diagrams and check fuel
General electrical - Circuit INJECTOR_4B - injector no.8 circuit for short
failure INJECTOR_4B_COMMON - circuit to ground, short circuit
to power
Fuel injector no.8 circuit short circuit
to ground, short circuit to power

P0283- Cylinder 8 Injector NOTE: Refer to the electrical circuit


12 Circuit High - diagrams and check fuel
Circuit short to - Circuit INJECTOR_4B - injector no.8 circuit for short
battery INJECTOR_4B_COMMON - circuit to power

Fuel injector no.8 circuit short circuit


to power

P02EE- Cylinder 1 Injector NOTE: Refer to the electrical circuit


01 Circuit diagrams and check cylinder 1
Range/Performance - Circuit INJECTOR_1A - injector circuit for short circuit
- General electrical INJECTOR_1A_COMMON - to power, short circuit together
failure Check and install a new
Cylinder 1 injector low circuit short cylinder 1 injector as required.
circuit to power Refer to the warranty policy
Cylinder 1 injector low circuit shorted and procedures manual, or
to high circuit determine if any prior approval
Cylinder 1 injector failure programme is in operation,
prior to the installation of a new
module/component

P02EE- Cylinder 1 Injector NOTE: Using the Jaguar Land Rover


1C Circuit approved diagnostic equipment,
Range/Performance - Circuit INJECTOR_1A - check engine control module,
- Circuit voltage INJECTOR_1A_COMMON - for related DTCs and refer to
out of range the relevant DTC index
Engine control module failure
P02EF- Cylinder 2 Injector NOTE: Refer to the electrical circuit
01 Circuit diagrams and check cylinder 2
Range/Performance - Circuit INJECTOR_1B - injector circuit for short circuit
- General electrical INJECTOR_1B_COMMON - to power, short circuit together
failure Check and install a new
Cylinder 2 injector low circuit short cylinder 2 injector as required.
circuit to power Refer to the warranty policy
Cylinder 2 injector low circuit shorted and procedures manual, or
to high circuit determine if any prior approval
Cylinder 2 injector failure programme is in operation,
prior to the installation of a new
module/component

P02EF- Cylinder 2 Injector NOTE: Using the Jaguar Land Rover


1C Circuit approved diagnostic equipment,
Range/Performance - Circuit INJECTOR_1B - check engine control module,
- Circuit voltage INJECTOR_1B_COMMON - for related DTCs and refer to
out of range the relevant DTC index
Engine control module failure

P02F0- Cylinder 3 Injector NOTE: Refer to the electrical circuit


01 Circuit diagrams and check cylinder 3
Range/Performance - Circuit INJECTOR_2A - injector circuit for short circuit
- General electrical INJECTOR_2A_COMMON - to power, short circuit together
failure Check and install a new
Cylinder 3 injector low circuit short cylinder 3 injector as required.
circuit to power Refer to the warranty policy
Cylinder 3 injector low circuit shorted and procedures manual, or
to high circuit determine if any prior approval
Cylinder 3 injector failure programme is in operation,
prior to the installation of a new
module/component

P02F0- Cylinder 3 Injector NOTE: Using the Jaguar Land Rover


1C Circuit approved diagnostic equipment,
Range/Performance - Circuit INJECTOR_2A - check engine control module,
- Circuit voltage INJECTOR_2A_COMMON - for related DTCs and refer to
out of range the relevant DTC index
Engine control module failure

P02F1- Cylinder 4 Injector NOTE: Refer to the electrical circuit


01 Circuit diagrams and check cylinder 4
Range/Performance - Circuit INJECTOR_2B - injector circuit for short circuit
- General electrical INJECTOR_2B_COMMON - to power, short circuit together
failure Check and install a new
Cylinder 4 injector low circuit short cylinder 4 injector as required.
circuit to power Refer to the warranty policy
Cylinder 4 injector low circuit shorted and procedures manual, or
to high circuit determine if any prior approval
Cylinder 4 injector failure programme is in operation,
prior to the installation of a new
module/component

P02F1- Cylinder 4 Injector NOTE: Using the Jaguar Land Rover


1C Circuit approved diagnostic equipment,
Range/Performance - Circuit INJECTOR_2B - check engine control module,
- Circuit voltage INJECTOR_2B_COMMON - for related DTCs and refer to
out of range the relevant DTC index
Engine control module failure

P02F2- Cylinder 5 Injector NOTE: Refer to the electrical circuit


01 Circuit diagrams and check cylinder 5
Range/Performance - Circuit INJECTOR_3A - injector circuit for short circuit
- General electrical INJECTOR_3A_COMMON - to power, short circuit together
failure Check and install a new
Cylinder 5 injector low circuit short cylinder 5 injector as required.
circuit to power Refer to the warranty policy
Cylinder 5 injector low circuit shorted and procedures manual, or
to high circuit determine if any prior approval
Cylinder 5 injector failure programme is in operation,
prior to the installation of a new
module/component

P02F2- Cylinder 5 Injector NOTE: Using the Jaguar Land Rover


1C Circuit approved diagnostic equipment,
Range/Performance - Circuit INJECTOR_3A - check engine control module,
- Circuit voltage INJECTOR_3A_COMMON - for related DTCs and refer to
out of range the relevant DTC index
Engine control module failure

P02F3- Cylinder 6 Injector NOTE: Refer to the electrical circuit


01 Circuit diagrams and check cylinder 6
Range/Performance - Circuit INJECTOR_3B - injector circuit for short circuit
- General electrical INJECTOR_3B_COMMON - to power, short circuit together
failure Check and install a new
Cylinder 6 injector low circuit short cylinder 6 injector as required.
circuit to power Refer to the warranty policy
Cylinder 6 injector low circuit shorted and procedures manual, or
to high circuit determine if any prior approval
Cylinder 6 injector failure programme is in operation,
prior to the installation of a new
module/component

P02F3- Cylinder 6 Injector NOTE: Using the Jaguar Land Rover


1C Circuit approved diagnostic equipment,
Range/Performance - Circuit INJECTOR_3B - check engine control module,
- Circuit voltage INJECTOR_3B_COMMON - for related DTCs and refer to
out of range the relevant DTC index
Engine control module failure

P02F4- Cylinder 7 Injector NOTE: Refer to the electrical circuit


01 Circuit diagrams and check cylinder 7
Range/Performance - Circuit INJECTOR_4A - injector circuit for short circuit
- General electrical INJECTOR_4A_COMMON - to power, short circuit together
failure Check and install a new
Cylinder 7 injector low circuit short cylinder 7 injector as required.
circuit to power Refer to the warranty policy
Cylinder 7 injector low circuit shorted and procedures manual, or
to high circuit determine if any prior approval
Cylinder 7 injector failure programme is in operation,
prior to the installation of a new
module/component

P02F4- Cylinder 7 Injector NOTE: Using the Jaguar Land Rover


1C Circuit approved diagnostic equipment,
Range/Performance - Circuit INJECTOR_4A - check engine control module,
- Circuit voltage INJECTOR_4A_COMMON - for related DTCs and refer to
out of range the relevant DTC index
Engine control module failure

P02F5- Cylinder 8 Injector NOTE: Refer to the electrical circuit


01 Circuit diagrams and check cylinder 8
Range/Performance - Circuit INJECTOR_4B - injector circuit for short circuit
- General electrical INJECTOR_4B_COMMON - to power, short circuit together
failure Check and install a new
Cylinder 8 injector low circuit short cylinder 8 injector as required.
circuit to power Refer to the warranty policy
Cylinder 8 injector low circuit shorted and procedures manual, or
to high circuit determine if any prior approval
Cylinder 8 injector failure programme is in operation,
prior to the installation of a new
module/component

P02F5- Cylinder 8 Injector NOTE: Using the Jaguar Land Rover


1C Circuit approved diagnostic equipment,
Range/Performance - Circuit INJECTOR_4B - check engine control module,
- Circuit voltage INJECTOR_4B_COMMON - for related DTCs and refer to
out of range the relevant DTC index
Engine control module failure

P0300- Random Misfire NOTE: Check engine control module


00 Detected - No sub for related fuelling, ignition
type information Monitor description. Misfire detection coil, injector or individual
cylinder misfire DTCs and refer
Poor fuel supply to this DTC index. Rectify
Poor fuel quality these first
Fuel air ratio excessively too lean or If this DTC is raised with
too rich P0301-00, P0302-00, P0303-
Catalyst/exhaust system blockage 00, P0304-00, P0305-
Spark plug(s) fouled or failed 00,P0306-00,P0307-00, or
Low Cylinder compression P0308-00, then the fuel
Reluctor ring delivery system and air intake
Crankshaft position sensor failure system should be checked and
Camshaft position sensor failure rectified first
Injector or ignition coil connector is Using the Jaguar Land Rover
disconnected, connector pin is backed approved diagnostic equipment
out, connector pin corrosion clear all stored DTCs using the
Connector is disconnected, connector ‘Diagnosis Menu’ tab and retest
pin is backed out, connector pin Check the fuel system for
corrosion blockages or restrictions, repair
Injector circuit short circuit to ground, as required
short circuit to power, open circuit Check for air leaks within the
Injector(s) failure air intake system, repair as
required
Check the catalyst/exhaust
system for blockage, repair as
required
Check and install a new spark
plug(s) as required
Carry out cylinder compression
checks as required
Inspect reluctor ring for
damage
Check and install a new
crankshaft position sensor as
required
Check and install a new
camshaft position sensor as
required
Inspect connectors for signs of
water ingress, and pins for
damage and/or corrosion
Refer to the electrical circuit
diagrams and check injector(s)
circuit for short circuit to
ground, short circuit to power,
open circuit
Identify the misfiring cylinder.
Check and install a new injector
as required

P0301- Cylinder 1 Misfire NOTE: Check engine control module


00 Detected - No sub for related fuelling, ignition
type information Monitor description. Misfire detection coil, injector or individual
cylinder misfire DTCs and refer
Poor fuel supply to this DTC index. Rectify
Poor fuel quality these first
Fuel air ratio excessively too lean or If this DTC is raised with
too rich P0300-00, then the fuel
Catalyst/exhaust system blockage delivery system and air intake
Spark plug(s) fouled or failed system should be checked and
Low Cylinder compression rectified first
Reluctor ring Using the Jaguar Land Rover
Crankshaft position sensor failure approved diagnostic equipment
Camshaft position sensor failure clear all stored DTCs using the
Injector or ignition coil connector is ‘Diagnosis Menu’ tab and retest
disconnected, connector pin is backed Check the fuel system for
out, connector pin corrosion blockages or restrictions, repair
Connector is disconnected, connector as required
pin is backed out, connector pin Check for air leaks within the
corrosion air intake system, repair as
Injector circuit short circuit to ground, required
short circuit to power, open circuit Check the catalyst/exhaust
Injector(s) failure system for blockage, repair as
required
Check and install a new spark
plug(s) as required
Carry out cylinder compression
checks as required
Inspect reluctor ring for
damage
Check and install a new
crankshaft position sensor as
required
Check and install a new
camshaft position sensor as
required
Inspect connectors for signs of
water ingress, and pins for
damage and/or corrosion
Refer to the electrical circuit
diagrams and check injector(s)
circuit for short circuit to
ground, short circuit to power,
open circuit
Identify the misfiring cylinder.
Check and install a new injector
as required

P0302- Cylinder 2 Misfire NOTE: Check engine control module


00 Detected - No sub for related fuelling, ignition
type information Monitor description. Misfire detection coil, injector or individual
cylinder misfire DTCs and refer
Poor fuel supply to this DTC index. Rectify
Poor fuel quality these first
Fuel air ratio excessively too lean or If this DTC is raised with
too rich P0300-00, then the fuel
Catalyst/exhaust system blockage delivery system and air intake
Spark plug(s) fouled or failed system should be checked and
Low Cylinder compression rectified first
Reluctor ring Using the Jaguar Land Rover
Crankshaft position sensor failure approved diagnostic equipment
Camshaft position sensor failure clear all stored DTCs using the
Injector or ignition coil connector is ‘Diagnosis Menu’ tab and retest
disconnected, connector pin is backed Check the fuel system for
out, connector pin corrosion blockages or restrictions, repair
Connector is disconnected, connector as required
pin is backed out, connector pin Check for air leaks within the
corrosion air intake system, repair as
Injector circuit short circuit to ground, required
short circuit to power, open circuit Check the catalyst/exhaust
Injector(s) failure system for blockage, repair as
required
Check and install a new spark
plug(s) as required
Carry out cylinder compression
checks as required
Inspect reluctor ring for
damage
Check and install a new
crankshaft position sensor as
required
Check and install a new
camshaft position sensor as
required
Inspect connectors for signs of
water ingress, and pins for
damage and/or corrosion
Refer to the electrical circuit
diagrams and check injector(s)
circuit for short circuit to
ground, short circuit to power,
open circuit
Identify the misfiring cylinder.
Check and install a new injector
as required

P0303- Cylinder 3 Misfire NOTE: Check engine control module


00 Detected - No sub for related fuelling, ignition
type information Monitor description. Misfire detection coil, injector or individual
cylinder misfire DTCs and refer
Poor fuel supply to this DTC index. Rectify
Poor fuel quality these first
Fuel air ratio excessively too lean or If this DTC is raised with
too rich P0300-00, then the fuel
Catalyst/exhaust system blockage delivery system and air intake
Spark plug(s) fouled or failed system should be checked and
Low Cylinder compression rectified first
Reluctor ring Using the Jaguar Land Rover
Crankshaft position sensor failure approved diagnostic equipment
Camshaft position sensor failure clear all stored DTCs using the
Injector or ignition coil connector is ‘Diagnosis Menu’ tab and retest
disconnected, connector pin is backed Check the fuel system for
out, connector pin corrosion blockages or restrictions, repair
Connector is disconnected, connector as required
pin is backed out, connector pin Check for air leaks within the
corrosion air intake system, repair as
Injector circuit short circuit to ground, required
short circuit to power, open circuit Check the catalyst/exhaust
Injector(s) failure system for blockage, repair as
required
Check and install a new spark
plug(s) as required
Carry out cylinder compression
checks as required
Inspect reluctor ring for
damage
Check and install a new
crankshaft position sensor as
required
Check and install a new
camshaft position sensor as
required
Inspect connectors for signs of
water ingress, and pins for
damage and/or corrosion
Refer to the electrical circuit
diagrams and check injector(s)
circuit for short circuit to
ground, short circuit to power,
open circuit
Identify the misfiring cylinder.
Check and install a new injector
as required

P0304- Cylinder 4 Misfire NOTE: Check engine control module


00 Detected - No sub for related fuelling, ignition
type information Monitor description. Misfire detection coil, injector or individual
cylinder misfire DTCs and refer
Poor fuel supply to this DTC index. Rectify
Poor fuel quality these first
Fuel air ratio excessively too lean or If this DTC is raised with
too rich P0300-00, then the fuel
Catalyst/exhaust system blockage delivery system and air intake
Spark plug(s) fouled or failed system should be checked and
Low Cylinder compression rectified first
Reluctor ring Using the Jaguar Land Rover
Crankshaft position sensor failure approved diagnostic equipment
Camshaft position sensor failure clear all stored DTCs using the
Injector or ignition coil connector is ‘Diagnosis Menu’ tab and retest
disconnected, connector pin is backed Check the fuel system for
out, connector pin corrosion blockages or restrictions, repair
Connector is disconnected, connector as required
pin is backed out, connector pin Check for air leaks within the
corrosion air intake system, repair as
Injector circuit short circuit to ground, required
short circuit to power, open circuit Check the catalyst/exhaust
Injector(s) failure system for blockage, repair as
required
Check and install a new spark
plug(s) as required
Carry out cylinder compression
checks as required
Inspect reluctor ring for
damage
Check and install a new
crankshaft position sensor as
required
Check and install a new
camshaft position sensor as
required
Inspect connectors for signs of
water ingress, and pins for
damage and/or corrosion
Refer to the electrical circuit
diagrams and check injector(s)
circuit for short circuit to
ground, short circuit to power,
open circuit
Identify the misfiring cylinder.
Check and install a new injector
as required

P0305- Cylinder 5 Misfire NOTE: Check engine control module


00 Detected - No sub for related fuelling, ignition
type information Monitor description. Misfire detection coil, injector or individual
cylinder misfire DTCs and refer
Poor fuel supply to this DTC index. Rectify
Poor fuel quality these first
Fuel air ratio excessively too lean or If this DTC is raised with
too rich P0300-00, then the fuel
Catalyst/exhaust system blockage delivery system and air intake
Spark plug(s) fouled or failed system should be checked and
Low Cylinder compression rectified first
Reluctor ring Using the Jaguar Land Rover
Crankshaft position sensor failure approved diagnostic equipment
Camshaft position sensor failure clear all stored DTCs using the
Injector or ignition coil connector is ‘Diagnosis Menu’ tab and retest
disconnected, connector pin is backed Check the fuel system for
out, connector pin corrosion blockages or restrictions, repair
Connector is disconnected, connector as required
pin is backed out, connector pin Check for air leaks within the
corrosion air intake system, repair as
Injector circuit short circuit to ground, required
short circuit to power, open circuit Check the catalyst/exhaust
Injector(s) failure system for blockage, repair as
required
Check and install a new spark
plug(s) as required
Carry out cylinder compression
checks as required
Inspect reluctor ring for
damage
Check and install a new
crankshaft position sensor as
required
Check and install a new
camshaft position sensor as
required
Inspect connectors for signs of
water ingress, and pins for
damage and/or corrosion
Refer to the electrical circuit
diagrams and check injector(s)
circuit for short circuit to
ground, short circuit to power,
open circuit
Identify the misfiring cylinder.
Check and install a new injector
as required

P0306- Cylinder 6 Misfire NOTE: Check engine control module


00 Detected - No sub for related fuelling, ignition
type information Monitor description. Misfire detection coil, injector or individual
cylinder misfire DTCs and refer
Poor fuel supply to this DTC index. Rectify
Poor fuel quality these first
Fuel air ratio excessively too lean or If this DTC is raised with
too rich P0300-00, then the fuel
Catalyst/exhaust system blockage delivery system and air intake
Spark plug(s) fouled or failed system should be checked and
Low Cylinder compression rectified first
Reluctor ring Using the Jaguar Land Rover
Crankshaft position sensor failure approved diagnostic equipment
Camshaft position sensor failure clear all stored DTCs using the
Injector or ignition coil connector is ‘Diagnosis Menu’ tab and retest
disconnected, connector pin is backed Check the fuel system for
out, connector pin corrosion blockages or restrictions, repair
Connector is disconnected, connector as required
pin is backed out, connector pin Check for air leaks within the
corrosion air intake system, repair as
Injector circuit short circuit to ground, required
short circuit to power, open circuit Check the catalyst/exhaust
Injector(s) failure system for blockage, repair as
required
Check and install a new spark
plug(s) as required
Carry out cylinder compression
checks as required
Inspect reluctor ring for
damage
Check and install a new
crankshaft position sensor as
required
Check and install a new
camshaft position sensor as
required
Inspect connectors for signs of
water ingress, and pins for
damage and/or corrosion
Refer to the electrical circuit
diagrams and check injector(s)
circuit for short circuit to
ground, short circuit to power,
open circuit
Identify the misfiring cylinder.
Check and install a new injector
as required

P0307- Cylinder 7 Misfire NOTE: Check engine control module


00 Detected - No sub for related fuelling, ignition
type information Monitor description. Misfire detection coil, injector or individual
cylinder misfire DTCs and refer
Poor fuel supply to this DTC index. Rectify
Poor fuel quality these first
Fuel air ratio excessively too lean or If this DTC is raised with
too rich P0300-00, then the fuel
Catalyst/exhaust system blockage delivery system and air intake
Spark plug(s) fouled or failed system should be checked and
Low Cylinder compression rectified first
Reluctor ring Using the Jaguar Land Rover
Crankshaft position sensor failure approved diagnostic equipment
Camshaft position sensor failure clear all stored DTCs using the
Injector or ignition coil connector is ‘Diagnosis Menu’ tab and retest
disconnected, connector pin is backed Check the fuel system for
out, connector pin corrosion blockages or restrictions, repair
Connector is disconnected, connector as required
pin is backed out, connector pin Check for air leaks within the
corrosion air intake system, repair as
Injector circuit short circuit to ground, required
short circuit to power, open circuit Check the catalyst/exhaust
Injector(s) failure system for blockage, repair as
required
Check and install a new spark
plug(s) as required
Carry out cylinder compression
checks as required
Inspect reluctor ring for
damage
Check and install a new
crankshaft position sensor as
required
Check and install a new
camshaft position sensor as
required
Inspect connectors for signs of
water ingress, and pins for
damage and/or corrosion
Refer to the electrical circuit
diagrams and check injector(s)
circuit for short circuit to
ground, short circuit to power,
open circuit
Identify the misfiring cylinder.
Check and install a new injector
as required

P0308- Cylinder 8 Misfire NOTE: Check engine control module


00 Detected - No sub for related fuelling, ignition
type information Monitor description. Misfire detection coil, injector or individual
cylinder misfire DTCs and refer
Poor fuel supply to this DTC index. Rectify
Poor fuel quality these first
Fuel air ratio excessively too lean or If this DTC is raised with
too rich P0300-00, then the fuel
Catalyst/exhaust system blockage delivery system and air intake
Spark plug(s) fouled or failed system should be checked and
Low Cylinder compression rectified first
Reluctor ring Using the Jaguar Land Rover
Crankshaft position sensor failure approved diagnostic equipment
Camshaft position sensor failure clear all stored DTCs using the
Injector or ignition coil connector is ‘Diagnosis Menu’ tab and retest
disconnected, connector pin is backed Check the fuel system for
out, connector pin corrosion blockages or restrictions, repair
Connector is disconnected, connector as required
pin is backed out, connector pin Check for air leaks within the
corrosion air intake system, repair as
Injector circuit short circuit to ground, required
short circuit to power, open circuit Check the catalyst/exhaust
Injector(s) failure system for blockage, repair as
required
Check and install a new spark
plug(s) as required
Carry out cylinder compression
checks as required
Inspect reluctor ring for
damage
Check and install a new
crankshaft position sensor as
required
Check and install a new
camshaft position sensor as
required
Inspect connectors for signs of
water ingress, and pins for
damage and/or corrosion
Refer to the electrical circuit
diagrams and check injector(s)
circuit for short circuit to
ground, short circuit to power,
open circuit
Identify the misfiring cylinder.
Check and install a new injector
as required

P0313- Misfire Detected Poor fuel quality Using the Jaguar Land Rover
00 With Low Fuel - Catalyst/exhaust system blockage approved diagnostic equipment,
No sub type Spark plug(s) fouled or failed check engine control module,
information Coil(s) failure for related DTCs and refer to
Injector(s) circuit short circuit to the relevant DTC index
ground, short circuit to power, open Check the fuel system for
circuit blockages, repair as required
Injector(s) failure Check the catalyst/exhaust
Fuel system excessively too lean or too system for blockage, repair as
rich required
Camshaft position sensor failure Check and install a new spark
plug(s) as required
Check and install a new coil(s)
as required
Refer to the electrical circuit
diagrams and check injector(s)
circuit for short circuit to
ground, short circuit to power,
open circuit
Check and install a new
injector(s) as required
Check for air leaks within the
intake system
Check and install a new
camshaft position sensor as
required
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0316- Misfire Detected Poor fuel quality Using the Jaguar Land Rover
00 On Startup (First Catalyst/exhaust system blockage approved diagnostic equipment,
1000 Revolutions) - Spark plug(s) fouled or failed check engine control module,
No sub type Coil(s) failure for related DTCs and refer to
information Injector(s) circuit short circuit to the relevant DTC index
ground, short circuit to power, open Check the fuel system for
circuit blockages, repair as required
Injector(s) failure Check the catalyst/exhaust
Fuel system excessively too lean or too system for blockage, repair as
rich required
Camshaft position sensor failure Check and install a new spark
plug(s) as required
Check and install a new coil(s)
as required
Refer to the electrical circuit
diagrams and check injector(s)
circuit for short circuit to
ground, short circuit to power,
open circuit
Check and install a new
injector(s) as required
Check for air leaks within the
intake system
Check and install a new
camshaft position sensor as
required
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0327- Knock Sensor 1 NOTE: Ensure a good electrical contact


00 Circuit Low with the cylinder block
(Bank1) - No sub - Circuit KNOCK_SENSOR_1A_POS - Refer to the electrical circuit
type information diagrams and check knock
Poor sensor contact with the cylinder sensor bank 1 front circuit for
block short circuit to ground, open
Knock sensor bank 1 front circuit short circuit
circuit to ground, open circuit Check and install a new knock
Knock sensor bank 1 front failure sensor bank 1 front as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0328- Knock Sensor 1 NOTE: Ensure a good electrical contact


00 Circuit High (Bank with the cylinder block
1) - No sub type - Circuit KNOCK_SENSOR_1A_POS - Refer to the electrical circuit
information diagrams and check knock
Poor sensor contact with the cylinder sensor bank 1 front circuit for
block short circuit to power, high
Knock sensor bank 1 front circuit high resistance
resistance, short circuit to power Check and install a new knock
Knock sensor bank 1 front failure sensor bank 1 front as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P032C- Knock Sensor 3 NOTE: Ensure a good electrical contact


00 Circuit Low with the cylinder block
(Bank1) - No sub - Circuit KNOCK_SENSOR_2A_POS - Refer to the electrical circuit
type information diagrams and check knock
Poor sensor contact with the cylinder sensor bank 2 front circuit for
block short circuit to ground
Knock sensor bank 2 front circuit short Check and install a new knock
circuit to ground sensor bank 2 front as required.
Knock sensor bank 2 front failure Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P032D- Knock Sensor 3 NOTE: Ensure a good electrical contact


00 Circuit High with the cylinder block
(Bank1) - No sub - Circuit KNOCK_SENSOR_2A_POS - Refer to the electrical circuit
type information diagrams and check knock
Poor sensor contact with the cylinder sensor bank 2 front circuit for
block short circuit to power, high
Knock sensor bank 2 front circuit high resistance
resistance, short circuit to power Check and install a new knock
Knock sensor bank 2 front failure sensor bank 2 front as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0332- Knock Sensor 2 NOTE: Ensure a good electrical contact


00 Circuit Low with the cylinder block
(Bank2) - No sub - Circuit KNOCK_SENSOR_1B_POS - Refer to the electrical circuit
type information diagrams and check knock
Poor sensor contact with the cylinder sensor bank 1 rear circuit for
block short circuit to ground, open
Knock sensor bank 1 rear circuit short circuit
circuit to ground, open circuit Check and install a new knock
Knock sensor bank 1 rear failure sensor bank 1 rear as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0333- Knock Sensor 2 NOTE: Ensure a good electrical contact


00 Circuit High (Bank with the cylinder block
2) - No sub type - Circuit KNOCK_SENSOR_1B_POS - Refer to the electrical circuit
information diagrams and check knock
Poor sensor contact with the cylinder sensor bank 1 rear circuit for
block short circuit to power
Knock sensor bank 1 rear circuit short Check and install a new knock
circuit to power sensor bank 1 rear as required.
Knock sensor bank 1 rear failure Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0335- Crankshaft Position NOTE: Refer to the electrical circuit


02 Sensor A Circuit - diagrams and check crankshaft
General signal - Circuit CRANK_SENSOR - position sensor circuit for short
failure circuit to ground, short circuit
Crankshaft position sensor circuit short to power, high resistance,
circuit to ground, short circuit to
disconnected
power, high resistance, disconnected Check and install new
Crankshaft position sensor failure crankshaft position as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0335- Crankshaft Position NOTE: Refer to the electrical circuit


31 Sensor A Circuit - diagrams and check crankshaft
No signal - Circuit CRANK_SENSOR - position sensor circuit for short
circuit to ground, short circuit
Crankshaft position sensor circuit - to power, high resistance,
short circuit to ground, short circuit to disconnected
power, high resistance, disconnected Check and install new
Crankshaft position sensor failure crankshaft position as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0336- Crankshaft Position NOTE: Refer to the electrical circuit


00 Sensor A Circuit diagrams and check crankshaft
Range/Performance - Circuit CRANK_SENSOR - position sensor circuit for short
- No sub type circuit to ground, short circuit
information Crankshaft position sensor circuit short to power, high resistance,
circuit to ground, short circuit to disconnected
power, high resistance, disconnected Check crankshaft position
Crankshaft position sensor gap sensor for damage and check
incorrect, foreign matter on sensor air gap (check at 90B0
face, damaged teeth on rotor intervals, should be no greater
Crankshaft position sensor failure than 4.5mm)
Check and install new
crankshaft position as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P033C- Knock Sensor 4 NOTE: Ensure a good electrical contact


00 Circuit Low (Bank with the cylinder block
2) - No sub type - Circuit KNOCK_SENSOR_2B_POS - Refer to the electrical circuit
information diagrams and check knock
Poor sensor contact with the cylinder sensor bank 2 rear circuit for
block short circuit to ground
Knock sensor bank 2 rear circuit short Check and install a new knock
circuit to ground sensor bank 2 rear as required.
Knock sensor bank 2 rear failure Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P033D- Knock Sensor 4 NOTE: Ensure a good electrical contact


00 Circuit High (Bank with the cylinder block
2) - No sub type - Circuit KNOCK_SENSOR_2B_POS - Refer to the electrical circuit
information diagrams and check knock
Poor sensor contact with the cylinder sensor bank 2 rear circuit for
block short circuit to power, high
Knock sensor bank 2 rear circuit high resistance
resistance, short circuit to power Check and install a new knock
Knock sensor bank 2 rear failure sensor bank 2 rear as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0340- Camshaft Position NOTE: Refer to the electrical circuit


02 Sensor A Circuit diagrams and check camshaft
(Bank 1 or single - Circuit CAM_IN_SENSOR_A - position sensor bank 1 inlet
sensor) - General sensor circuit for short circuit to
signal failure Camshaft position sensor bank 1 inlet ground, short circuit to power,
sensor circuit short circuit to ground, high resistance, disconnected
short circuit to power, high resistance, Check camshaft position sensor
disconnected bank 1 inlet sensor for correct
Camshaft position sensor bank 1 inlet installation and damage
sensor gap incorrect, foreign matter on Check and install a new
sensor face, damaged rotor camshaft position sensor bank 1
Camshaft position sensor bank 1 inlet inlet as required. Refer to the
sensor failure warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P0340- Camshaft Position NOTE: Refer to the electrical circuit


31 Sensor A Circuit diagrams and check camshaft
(Bank 1 or single - Circuit CAM_IN_SENSOR_A - position sensor bank 1 inlet
sensor) - No signal sensor circuit for short circuit to
Camshaft position sensor bank 1 inlet ground, short circuit to power,
sensor circuit short circuit to ground, high resistance, disconnected
short circuit to power, high resistance, Check camshaft position sensor
disconnected bank 1 inlet sensor for correct
Camshaft position sensor bank 1 inlet installation and damage
sensor gap incorrect, foreign matter on Check and install a new
sensor face, damaged rotor camshaft position sensor bank 1
Camshaft position sensor bank 1 inlet inlet as required. Refer to the
sensor failure warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component
P0341- Camshaft Position NOTE: Refer to the electrical circuit
00 Sensor A Circuit diagrams and check camshaft
Range/Performance - Circuit CAM_IN_SENSOR_A - position sensor bank 1 inlet
(Bank 1 or single sensor circuit for short circuit to
sensor) - No sub Camshaft position sensor bank 1 inlet ground, short circuit to power,
type information sensor circuit short circuit to ground, high resistance, disconnected
short circuit to power, high resistance, Check camshaft position sensor
disconnected bank 1 inlet sensor for correct
Camshaft position sensor bank 1 inlet installation and damage
sensor gap incorrect, foreign matter on Check and install a new
sensor face, damaged rotor camshaft position sensor bank 1
Camshaft position sensor bank 1 inlet inlet as required. Refer to the
sensor failure warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P0345- Camshaft Position NOTE: Refer to the electrical circuit


02 Sensor A Circuit diagrams and check camshaft
(Bank 2) - General - Circuit CAM_IN_SENSOR_B - position sensor bank 2 inlet
signal failure sensor circuit for short circuit to
Camshaft position sensor bank 2 inlet ground, short circuit to power,
sensor circuit short circuit to ground, high resistance, disconnected
short circuit to power, high resistance, Check camshaft position sensor
disconnected bank 2 inlet sensor for correct
Camshaft position sensor bank 2 inlet installation and damage
sensor gap incorrect, foreign matter on Check and install a new
sensor face, damaged rotor camshaft position sensor bank 2
Camshaft position sensor bank 2 inlet inlet as required. Refer to the
sensor failure warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P0345- Camshaft Position NOTE: Refer to the electrical circuit


31 Sensor A Circuit diagrams and check camshaft
(Bank 2) - No - Circuit CAM_IN_SENSOR_B - position sensor bank 2 inlet
signal sensor circuit for short circuit to
Camshaft position sensor bank 2 inlet ground, short circuit to power,
sensor circuit - short circuit to ground, high resistance, disconnected
short circuit to power, high resistance, Check camshaft position sensor
disconnected bank 2 inlet sensor for correct
Camshaft position sensor bank 2 inlet installation and damage
sensor gap incorrect, foreign matter on Check and install a new
sensor face, damaged rotor camshaft position sensor bank 2
Camshaft position sensor bank 2 inlet inlet as required. Refer to the
sensor failure warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component
P0346- Camshaft Position NOTE: Refer to the electrical circuit
00 Sensor A Circuit diagrams and check camshaft
Range/Performance - Circuit CAM_IN_SENSOR_B - position sensor bank 2 inlet
(Bank 2) - No sub sensor circuit for short circuit to
type information Camshaft position sensor bank 2 inlet ground, short circuit to power,
sensor circuit - short circuit to ground, high resistance, disconnected
short circuit to power, high resistance, Check camshaft position sensor
disconnected bank 2 inlet sensor for correct
Camshaft position sensor bank 2 inlet installation and damage
sensor gap incorrect, foreign matter on Check target rotor for run out,
sensor face, target rotor run-out repair as required
Camshaft position sensor bank 2 inlet Check and install a new
sensor failure camshaft position sensor bank 2
inlet as required. Refer to the
warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P0351- Ignition Coil A NOTE: Refer to the electrical circuit


13 Primary/Secondary diagrams and check ignition
Circuit - Circuit - Circuit IGNITION_1A - coil 1 circuit for open circuit,
open disconnected ignition coil, high
Ignition coil 1 open circuit resistance
Ignition coil 1 disconnected
Ignition coil high resistance

P0352- Ignition Coil B NOTE: Refer to the electrical circuit


13 Primary/Secondary diagrams and check ignition
Circuit - Circuit - Circuit IGNITION_1B - coil 2 circuit for open circuit,
open disconnected ignition coil, high
Ignition coil 2 open circuit resistance
Ignition coil 2 disconnected
Ignition coil high resistance

P0353- Ignition Coil C NOTE: Refer to the electrical circuit


13 Primary/Secondary diagrams and check ignition
Circuit - Circuit - Circuit IGNITION_2A - coil 3 circuit for open circuit,
open disconnected ignition coil, high
Ignition coil 3 open circuit resistance
Ignition coil 3 disconnected
Ignition coil high resistance

P0354- Ignition Coil D NOTE: Refer to the electrical circuit


13 Primary/Secondary diagrams and check ignition
Circuit - Circuit - Circuit IGNITION_2B - coil 4 circuit for open circuit,
open disconnected ignition coil, high
Ignition coil 4 open circuit resistance
Ignition coil 4 disconnected
Ignition coil high resistance

P0355- Ignition Coil E NOTE: Refer to the electrical circuit


13 Primary/Secondary diagrams and check ignition
Circuit - Circuit - Circuit IGNITION_3A - coil 5 circuit for open circuit,
open disconnected ignition coil, high
Ignition coil 5 open circuit resistance
Ignition coil 5 disconnected
Ignition coil high resistance

P0356- Ignition Coil F NOTE: Refer to the electrical circuit


13 Primary/Secondary diagrams and check ignition
Circuit - Circuit - Circuit IGNITION_3B - coil 6 circuit for open circuit,
open disconnected ignition coil, high
Ignition coil 6 open circuit resistance
Ignition coil 6 disconnected
Ignition coil high resistance

P0357- Ignition Coil G NOTE: Refer to the electrical circuit


13 Primary/Secondary diagrams and check ignition
Circuit - Circuit - Circuit IGNITION_4A - coil 7 circuit for open circuit,
open disconnected ignition coil, high
Ignition coil 7 open circuit resistance
Ignition coil 7 disconnected
Ignition coil high resistance

P0358- Ignition Coil H NOTE: Refer to the electrical circuit


13 Primary/Secondary diagrams and check ignition
Circuit - Circuit - Circuit IGNITION_4B - coil 8 circuit for open circuit,
open disconnected ignition coil, high
Ignition coil 8 open circuit resistance
Ignition coil 8 disconnected
Ignition coil high resistance

P0365- Camshaft Position NOTE: Refer to the electrical circuit


02 Sensor B Circuit diagrams and check camshaft
(Bank 1) - General - Circuit CAM_EX_SENSOR_A - position sensor bank 1 outlet
signal failure sensor circuit for short circuit to
Camshaft position sensor bank 1 outlet ground, short circuit to power,
sensor circuit short circuit to ground, high resistance, disconnected
short circuit to power, high resistance, Check camshaft position sensor
disconnected bank 1 outlet sensor for correct
Camshaft position sensor bank 1 outlet installation and damage
sensor gap incorrect, foreign matter on Check and install a new
sensor face, damaged rotor camshaft position sensor bank 1
Camshaft position sensor bank 1 outlet outlet as required. Refer to the
sensor failure warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P0366- Camshaft Position NOTE: Refer to the electrical circuit


00 Sensor B Circuit diagrams and check camshaft
Range/Performance - Circuit CAM_EX_SENSOR_A - position sensor bank 1 outlet
(Bank 1) - No sub sensor circuit for short circuit to
type information Camshaft position sensor bank 1 outlet ground, short circuit to power,
sensor circuit short circuit to ground, high resistance, disconnected
short circuit to power, high resistance, Check camshaft position sensor
disconnected bank 1 outlet sensor for correct
Camshaft position sensor bank 1 outlet installation and damage
sensor gap incorrect, foreign matter on Check target run-out, repair as
sensor face, target rotor run-out required
Camshaft position sensor bank 1 outlet Check and install a new
sensor failure camshaft position sensor bank 1
outlet as required. Refer to the
warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P0390- Camshaft Position NOTE: Refer to the electrical circuit


02 Sensor B Circuit diagrams and check camshaft
(Bank 2) - General - Circuit CAM_EX_SENSOR_B - position sensor bank 2 outlet
signal failure sensor circuit for short circuit to
Camshaft position sensor bank 2 outlet ground, short circuit to power,
sensor circuit short circuit to ground, high resistance, disconnected
short circuit to power, high resistance, Check camshaft position sensor
disconnected bank 2 outlet sensor for correct
Camshaft position sensor bank 2 outlet installation and damage
sensor gap incorrect, foreign matter on Check and install a new
sensor face, damaged rotor camshaft position sensor bank 2
Camshaft position sensor bank 2 outlet outlet as required. Refer to the
sensor failure warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P0391- Camshaft Position NOTE: Refer to the electrical circuit


00 Sensor B Circuit diagrams and check camshaft
Range/Performance - Circuit CAM_EX_SENSOR_B - position sensor bank 2 outlet
(Bank 2) - No sub sensor circuit for short circuit to
type information Camshaft position sensor bank 2 outlet ground, short circuit to power,
sensor circuit short circuit to ground, high resistance, disconnected
short circuit to power, high resistance, Check camshaft position sensor
disconnected bank 2 outlet sensor for correct
Camshaft position sensor bank 2 outlet installation and damage
sensor gap incorrect, foreign matter on Check target rotor, repair as
sensor face, damaged rotor, rotor run- required
out Check and install a new
Camshaft position sensor bank 2 outlet camshaft position sensor bank 2
sensor failure outlet as required. Refer to the
warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P0420- Catalyst System Catalytic converter failure due to Using the Jaguar Land Rover
00 Efficiency Below overheating damage caused by misfire approved diagnostic equipment,
Threshold (Bank 1) and/or lean combustion check for misfire/lean
- No sub type Catalytic converter failure due to combustion related DTCs and
information poisoning caused by excessive oil refer to the relevant DTC index
consumption and/or contaminated fuel Check the oil and fuel
condition/level
Check the catalytic converter
for damage
Check and install a new
catalytic converter bank 1 as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0430- Catalyst System Catalytic converter failure due to Using the Jaguar Land Rover
00 Efficiency Below overheating damage caused by misfire approved diagnostic equipment,
Threshold (Bank 2) and/or lean combustion check for misfire/lean
- No sub type Catalytic converter failure due to combustion related DTCs and
information poisoning caused by excessive oil refer to the relevant DTC index
consumption and/or contaminated fuel Check the oil and fuel
condition/level
Check the catalytic converter
for damage
Check and install a new
catalytic converter bank 2 as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0441- Evaporative NOTE: Check all evaporative emission


00 Emission System system hoses, pipes and
Incorrect Purge - Circuit PURGE_VALVE - connection are serviceable,
Flow - No sub type repair/replace as required
information Evaporative emission system hoses, Refer to the electrical circuit
pipes or connection failure diagrams and check purge
Purge control valve circuit short circuit control valve circuit for short
to ground, short circuit to power, open circuit to ground, short circuit
circuit, high resistance to power, open circuit
Purge control valve failure Check and install a new purge
control valve as required. Refer
to the warranty policy and
procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0442- Evaporative Evaporative emissions system leak NOTES:


00 Emission System
Leak Detected If purge valve related DTCs are
(small leak) - No also set, perform the relevant
sub type corrective action(s) first.
information
It is not possible to replicate the
failure event as certain entry
conditions must be satisfied
(for more information, refer to
section 303-13: Evaporative
Emissions / Description and
Operation). To verify the
customer concern, perform
routine Evaporative System
Diagnostic Check and re-read
DTCs.

Refer to the relevant section of


the workshop manual and
check the evaporative
emissions system for leaks. For
additional information, refer to:
Evaporative Emissions (303-
13B Evaporative Emissions -
V8 N/A 5.0L Petrol/V8 S/C
5.0L Petrol, Diagnosis and
Testing).

P0444- Evaporative Purge valve circuit open circuit, high Refer to the electrical circuit
13 Emission System resistance diagrams and check the purge
Purge Control valve circuit for open circuit,
Valve A Circuit high resistance
Open - Circuit open
P0447- Evaporative NOTES: Refer to the electrical circuit
00 Emission System diagrams and check diagnostic
Vent Control - Circuit COV - module tank leakage module
Circuit Open - No circuit for open circuit
sub type LR - Circuit CHANGE OVER Check diagnostic module tank
information VALVE - leakage module fuse and
replace as required
Diagnostic module tank leakage Check and install a new
module circuit open circuit diagnostic module tank leakage
Diagnostic module tank leakage module as required. Refer to
module circuit fuse blown / not secure the warranty policy and
in holder procedures manual, or
Diagnostic module tank leakage determine if any prior approval
module failure programme is in operation,
prior to the installation of a new
module/component

P0448- Evaporative NOTES: Refer to the electrical circuit


00 Emission System diagrams and check diagnostic
Vent Control - Circuit COV - module tank leakage module
Circuit Shorted - circuit for short circuit to
No sub type LR - Circuit CHANGE OVER ground, short circuit to power,
information VALVE - open circuit
Check and install a new
Diagnostic module tank leakage diagnostic module tank leakage
module circuit, short circuit to ground, module as required. Refer to
short circuit to power, open circuit the warranty policy and
Diagnostic module tank leakage procedures manual, or
module failure determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0456- Evaporative Evaporative emissions system leak NOTES:


00 Emission System
Leak Detected If purge valve related DTCs are
(very small leak) - also set, perform the relevant
No sub type corrective action(s) first.
information
It is not possible to replicate the
failure event as certain entry
conditions must be satisfied
(for more information, refer to
section 303-13: Evaporative
Emissions / Description and
Operation). To verify the
customer concern, perform
routine Evaporative System
Diagnostic Check and re-read
DTCs.

Refer to the relevant section of


the workshop manual and
check the evaporative
emissions system for leaks. For
additional information, refer to:
Evaporative Emissions (303-
13B Evaporative Emissions -
V8 N/A 5.0L Petrol/V8 S/C
5.0L Petrol, Diagnosis and
Testing).

P0458- Evaporative Purge valve circuit short circuit to Refer to the electrical circuit
11 Emission System ground diagrams and check the purge
Purge Control valve circuit for short circuit to
Valve Circuit Low ground
- Circuit short to
ground
P0459- Evaporative Purge valve circuit short circuit to Refer to the electrical circuit
12 Emission System power diagrams and check the purge
Purge Control valve circuit for short circuit to
Valve Circuit High power
- Circuit short to
battery
P0461- Fuel Level Sensor Fuel level sensor circuit open circuit, Refer to the electrical circuit
29 A Circuit short circuit to ground, short circuit to diagrams and check fuel level
Range/Performance power sensor circuit for short circuit to
- Signal invalid Fuel level sensor stuck ground, short circuit to power,
Fuel level sensor failure open circuit
Check for stuck level sensor
Check and install a new fuel
level sensor as required. Refer
to the warranty policy and
procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0461- Fuel Level Sensor Fuel level sensor circuit short circuit to Refer to the electrical circuit
2F A Circuit ground, short circuit to power, open diagrams and check fuel level
Range/Performance circuit sensor circuit for short circuit to
- Signal erratic Fuel level sensor track damaged ground, short circuit to power,
Fuel level sensor failure open circuit
Check level sensor track for
damage
Check and install a new fuel
level sensor as required. Refer
to the warranty policy and
procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0481- Fan 2 Control NOTE: Using the Jaguar Land Rover


04 Circuit - System approved diagnostic equipment
internal failures - Circuit RAD_FAN_PWM - check datalogger signal,
Electric Fan PWM Control -
Damaged cooling fan control unit Commanded Duty Cycle
Cooling fan control unit failure (0x03F9)
If fault persists, refer to the
relevant section of the
workshop manual and refer to
the cooling fan pinpoint test
procedures For additional
information, refer to: Engine
Cooling (303-03D Engine
Cooling - V8 N/A 5.0L
Petrol/V8 S/C 5.0L Petrol,
Diagnosis and Testing).
Check and install a new cooling
fan control unit as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0481- Fan 2 Control NOTE: Using the Jaguar Land Rover


09 Circuit - approved diagnostic equipment
Component failures - Circuit RAD_FAN_PWM - check datalogger signal,
Electric Fan PWM Control -
Damaged cooling fan control unit Commanded Duty Cycle
Cooling fan control unit failure (0x03F9)
If fault persists, refer to the
relevant section of the
workshop manual and refer to
the cooling fan pinpoint test
procedures For additional
information, refer to: Engine
Cooling (303-03D Engine
Cooling - V8 N/A 5.0L
Petrol/V8 S/C 5.0L Petrol,
Diagnosis and Testing).
Check and install a new cooling
fan control unit as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0481- Fan 2 Control NOTE: Using the Jaguar Land Rover


11 Circuit - Circuit approved diagnostic equipment
short to ground - Circuit RAD_FAN_PWM - check datalogger signal,
Electric Fan PWM Control -
Cooling fan control unit circuit short Commanded Duty Cycle
circuit to ground (0x03F9)
Refer to the electrical circuit
diagrams and check cooling fan
control unit circuit for short
circuit to ground
If fault persists, refer to the
relevant section of the
workshop manual and refer to
the cooling fan pinpoint test
procedures For additional
information, refer to: Engine
Cooling (303-03D Engine
Cooling - V8 N/A 5.0L
Petrol/V8 S/C 5.0L Petrol,
Diagnosis and Testing).

P0481- Fan 2 Control NOTE: Using the Jaguar Land Rover


12 Circuit - Circuit approved diagnostic equipment
short to battery - Circuit RAD_FAN_PWM - check datalogger signal,
Electric Fan PWM Control -
Cooling fan control unit circuit short Commanded Duty Cycle
circuit to power (0x03F9)
Refer to the electrical circuit
diagrams and check cooling fan
control unit circuit for short
circuit to power
If fault persists, refer to the
relevant section of the
workshop manual and refer to
the cooling fan pinpoint test
procedures For additional
information, refer to: Engine
Cooling (303-03D Engine
Cooling - V8 N/A 5.0L
Petrol/V8 S/C 5.0L Petrol,
Diagnosis and Testing).

P0481- Fan 2 Control NOTE: Using the Jaguar Land Rover


13 Circuit - Circuit approved diagnostic equipment
open - Circuit RAD_FAN_PWM - check datalogger signal,
Electric Fan PWM Control -
Cooling fan control unit circuit open Commanded Duty Cycle
circuit (0x03F9)
Refer to the electrical circuit
diagrams and check cooling fan
control unit circuit for open
circuit
If fault persists, refer to the
relevant section of the
workshop manual and refer to
the cooling fan pinpoint test
procedures For additional
information, refer to: Engine
Cooling (303-03D Engine
Cooling - V8 N/A 5.0L
Petrol/V8 S/C 5.0L Petrol,
Diagnosis and Testing).

P0481- Fan 2 Control NOTE: Using the Jaguar Land Rover


16 Circuit - Circuit approved diagnostic equipment
voltage below - Circuit RAD_FAN_PWM - check datalogger signal,
threshold Electric Fan PWM Control -
Charging system fault Commanded Duty Cycle
Discharged battery (0x03F9)
Refer to the electrical circuit
diagrams and check charging
circuit for open circuit, short
circuit to ground
If fault persists, refer to the
relevant section of the
workshop manual and refer to
the cooling fan pinpoint test
procedures For additional
information, refer to: Engine
Cooling (303-03D Engine
Cooling - V8 N/A 5.0L
Petrol/V8 S/C 5.0L Petrol,
Diagnosis and Testing).
Check and install a new
generator as required
Check and install a new battery
as required
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0481- Fan 2 Control NOTE: Using the Jaguar Land Rover


17 Circuit - Circuit approved diagnostic equipment
voltage above - Circuit RAD_FAN_PWM - check datalogger signal,
threshold Electric Fan PWM Control -
Charging system fault Commanded Duty Cycle
Discharged battery (0x03F9)
Refer to the electrical circuit
diagrams and check charging
circuit for open circuit, short
circuit to ground
If fault persists, refer to the
relevant section of the
workshop manual and refer to
the cooling fan pinpoint test
procedures For additional
information, refer to: Engine
Cooling (303-03D Engine
Cooling - V8 N/A 5.0L
Petrol/V8 S/C 5.0L Petrol,
Diagnosis and Testing).
Check and install a new
generator as required
Check and install a new battery
as required
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0481- Fan 2 Control NOTE: Using the Jaguar Land Rover


38 Circuit - Signal approved diagnostic equipment
frequency incorrect - Circuit RAD_FAN_PWM - check datalogger signal,
Electric Fan PWM Control -
Damaged cooling fan control unit Commanded Duty Cycle
Cooling fan control unit failure (0x03F9)
If fault persists, refer to the
relevant section of the
workshop manual and refer to
the cooling fan pinpoint test
procedures For additional
information, refer to: Engine
Cooling (303-03D Engine
Cooling - V8 N/A 5.0L
Petrol/V8 S/C 5.0L Petrol,
Diagnosis and Testing).
Check and install a new cooling
fan control unit as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0481- Fan 2 Control NOTE: Using the Jaguar Land Rover


4B Circuit - Over approved diagnostic equipment
temperature - Circuit RAD_FAN_PWM - check datalogger signal,
Electric Fan PWM Control -
Damaged cooling fan control unit Commanded Duty Cycle
Cooling fan control unit failure (0x03F9)
If fault persists, refer to the
relevant section of the
workshop manual and refer to
the cooling fan pinpoint test
procedures For additional
information, refer to: Engine
Cooling (303-03D Engine
Cooling - V8 N/A 5.0L
Petrol/V8 S/C 5.0L Petrol,
Diagnosis and Testing).
Check and install a new cooling
fan control unit as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0481- Fan 2 Control NOTE: Using the Jaguar Land Rover


93 Circuit - No approved diagnostic equipment
operation - Circuit RAD_FAN_PWM - check datalogger signal,
Electric Fan PWM Control -
Damaged cooling fan control unit Commanded Duty Cycle
Blocked cooling fan control unit (0x03F9)
Cooling fan control unit failure Check for blocked or
obstruction to fan rotor
If fault persists, refer to the
relevant section of the
workshop manual and refer to
the cooling fan pinpoint test
procedures For additional
information, refer to: Engine
Cooling (303-03D Engine
Cooling - V8 N/A 5.0L
Petrol/V8 S/C 5.0L Petrol,
Diagnosis and Testing).
Check and install a new cooling
fan control unit as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0481- Fan 2 Control NOTE: Using the Jaguar Land Rover


96 Circuit - approved diagnostic equipment
Component internal - Circuit RAD_FAN_PWM - check datalogger signal,
failure Electric Fan PWM Control -
Damaged cooling fan control unit Commanded Duty Cycle
Cooling fan control unit failure (0x03F9)
If fault persists, refer to the
relevant section of the
workshop manual and refer to
the cooling fan pinpoint test
procedures For additional
information, refer to: Engine
Cooling (303-03D Engine
Cooling - V8 N/A 5.0L
Petrol/V8 S/C 5.0L Petrol,
Diagnosis and Testing).
Check and install a new cooling
fan control unit as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0481- Fan 2 Control NOTE: Using the Jaguar Land Rover


97 Circuit - approved diagnostic equipment
Component or - Circuit RAD_FAN_PWM - check datalogger signal,
system operation Electric Fan PWM Control -
obstructed or Damaged cooling fan control unit Commanded Duty Cycle
blocked Blocked cooling fan control unit (0x03F9)
Cooling fan control unit failure Check for blocked or
obstruction to fan rotor
If fault persists, refer to the
relevant section of the
workshop manual and refer to
the cooling fan pinpoint test
procedures For additional
information, refer to: Engine
Cooling (303-03D Engine
Cooling - V8 N/A 5.0L
Petrol/V8 S/C 5.0L Petrol,
Diagnosis and Testing).
Check and install a new cooling
fan control unit as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0500- Vehicle Speed Wheel speed sensor fault Check anti-lock braking system
81 Sensor A - Invalid module for related DTCs and
serial data received refer to relevant DTC index

P0500- Vehicle Speed Anti-lock braking system module not Check anti-lock braking system
82 Sensor A - Alive / on bus module and engine control
sequence counter module for related DTCs and
incorrect / not refer to relevant DTC index
updated Refer to the electrical circuit
diagrams and check anti-lock
braking system module circuit
for short circuit to ground, short
circuit to power, open circuit

P0500- Vehicle Speed Incorrect level of anti-lock braking Clear DTC and re-test
83 Sensor A - Value of system module software Using the Jaguar Land Rover
signal protection Incorrect level of engine control approved diagnostic equipment
calculation module software check and install latest relevant
incorrect level of software to the anti-
lock braking system module
Using the Jaguar Land Rover
approved diagnostic equipment
check and install latest relevant
level of software to the engine
control module

P0500- Vehicle Speed Anti-lock braking system module has Check anti-lock braking system
85 Sensor A - Signal reported a speed above 300 km/h module for related DTCs and
above allowable refer to relevant DTC index
range
P0501- Vehicle Speed Vehicle speed from the anti-lock Check engine control module
62 Sensor A braking system module does not match for related vehicle speed DTCs
Range/Performance the calculated vehicle speed from the and refer to relevant DTC index
- Signal compare engine control module Check anti-lock braking system
failure module and transmission
control module for related
DTCs and refer to relevant
DTC index
Check the vehicle tire sizes are
correct

P0504- Brake Switch A / B No brake pressure signal available Check Anti-Lock braking
00 Correlation - No from anti-lock braking module module for related DTCs and
sub type Brake switch 1 and Brake switch 2 refer to relevant DTC index
information sense circuit short circuit to ground, Check for brake fluid leaks
short circuit to power, open circuit Refer to the electrical circuit
Brake switch 1 failure diagrams and check anti-lock
braking system module circuit
for short circuit to ground, short
circuit to power, open circuit
Refer to the electrical circuit
diagrams and check brake
switch circuit for short circuit
to ground, short circuit to
power, open circuit
Check and install a new brake
switch 1 as required. Refer to
the warranty policy and
procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0504- Brake Switch A / B NOTE: Check for brake fluid leaks


64 Correlation - Signal Refer to the electrical circuit
plausibility failure - Circuit BRAKE_SW - BRAKE_SW_2 - diagrams and check brake
switch 1 circuit for short circuit
Brake fluid leak to brake switch 2
Brake switch incorrectly Check brake switch is correctly
installed/adjusted installed and adjusted
Brake switch 1 sense circuit short Check and install a new brake
circuit to Brake switch 2 sense switch as required. Refer to the
Brake switch failure warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P0506- Idle Air Control Air intake restriction Ensure the air intake system is
00 System RPM Front end accessory drive overload free from restriction
Lower Than (defective/seized component) Check the front end accessory
Expected - No sub drive belt and components for
type information failure, repair as required

P0506- Idle Air Control Air intake restriction Ensure the air intake system is
24 System RPM Air intake system air leak between free from restriction
Lower Than MAF/IAT sensor and throttle Check for air leak between
Expected - Signal Intake air leak between throttle and MAF/IAT sensor and throttle
stuck high manifold Check for air leak between
Engine crankcase breather leak throttle and inlet manifold
Front end accessory drive overload Check for engine breather
(defective/seized component) system leak
Check the front end accessory
drive belt and components for
failure

P0507- Idle Air Control Air intake system air leak between Check for air leak between
00 System RPM MAF/IAT sensor and throttle MAF/IAT sensor and throttle
Higher Than Intake air leak between throttle and Check for air leak between
Expected - No sub manifold throttle and inlet manifold
type information Engine crankcase breather leak Check for engine breather
system leak

P0507- Idle Air Control Air intake restriction Ensure the air intake system is
23 System RPM Air intake system air leak between free from restriction
Higher Than MAF/IAT sensor and throttle Check for air leak between
Expected - Signal Intake air leak between throttle and MAF/IAT sensor and throttle
stuck low manifold Check for air leak between
Engine crankcase breather leak throttle and inlet manifold
Check for engine breather
system leak

P050B- Cold Start Ignition Ignition coil(s)faulty Refer to the electrical circuit
23 Timing Ignition coils circuit noise diagrams and check ignition
Performance - Engine control module failure coil circuit for short circuit to
Signal stuck low ground, short circuit to power,
open circuit
Refer to the electrical circuit
diagrams and check engine
control module to ignition coil
circuit for short circuit to power
Check and install a new coil(s)
as required
Refer to the electrical circuit
diagrams and check ignition
coils circuit for corrosion, high
resistance
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P050B- Cold Start Ignition Ignition coil(s)faulty Refer to the electrical circuit
24 Timing Ignition coils circuit noise diagrams and check ignition
Performance - Engine control module failure coil circuit for short circuit to
Signal stuck high ground, short circuit to power,
open circuit
Refer to the electrical circuit
diagrams and check engine
control module to ignition coil
circuit for short circuit to power
Check and install a new coil(s)
as required
Refer to the electrical circuit
diagrams and check ignition
coils circuit for corrosion, high
resistance
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P050E- Cold Start Engine Incorrect coolant temperature sensor Check the correct coolant
00 Exhaust installed temperature sensor is installed
Temperature Too Coolant temperature sensor circuit Refer to the electrical circuit
Low - No sub type short circuit to ground, open circuit diagrams and check coolant
information Coolant temperature sensor failure temperature sensor circuit for
short circuit to ground, open
circuit
Check and install a new coolant
temperature sensor as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0512- Starter Request NOTE: Refer to the electrical circuit


12 Circuit - Circuit diagrams and check crank
short to battery - Circuit CRANK_REQUEST - request circuit between engine
control module and central
Crank request circuit between engine junction box for short circuit to
control module and central junction power
box short circuit to power

P0512- Starter Request NOTE: Refer to the electrical circuit


14 Circuit - Circuit diagrams and check crank
short to ground or - Circuit CRANK_REQUEST - request circuit between engine
open control module and central
Crank request circuit between engine junction box for short circuit to
control module and central junction ground, open circuit
box short circuit to ground, open
circuit

P0513- Incorrect Security key invalid Check for CAN network


00 Immobilizer Key - Controller area network data interference/engine control
No sub type corruption module related error
information Low battery voltage Using the Jaguar Land Rover
approved diagnostic equipment,
complete a CAN network
integrity test
Check the vehicle charging
system for faults, repair as
required

P052A- Cold Start Intake NOTE: Check engine oil level and top
00 (A) Camshaft up as required
Position Timing - Circuit CAM_IN_SENSOR_A - Refer to the electrical circuit
Over-Advanced diagrams and check intake
(Bank 1) - No sub Engine oil pressure too low valve solenoid 1 sensor circuit
type information Intake valve solenoid 1 circuit short for short circuit to ground, open
circuit to ground, open circuit, high circuit, high resistance
resistance Check and install a new intake
Intake valve solenoid 1 failure valve solenoid 1 sensor as
Timing chains stretched beyond required
allowable limits Check service history /mileage
Check and install new timing
chains as required
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P052B- Cold Start Intake NOTE: Check engine oil level and top
00 (A) Camshaft up as required
Position Timing - Circuit CAM_IN_SENSOR_A - Refer to the electrical circuit
Over-Retarded diagrams and check intake
(Bank 1) - No sub Engine oil pressure too low valve solenoid 1 sensor circuit
type information Intake valve solenoid 1 circuit short for short circuit to ground, open
circuit to ground, open circuit, high circuit, high resistance
resistance Check and install a new intake
Intake valve solenoid 1 failure valve solenoid 1 sensor as
Timing chains stretched beyond required
allowable limits Check service history /mileage
Check and install new timing
chains as required
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P052C- Cold Start Intake NOTE: Check engine oil level and top
00 (A) Camshaft up as required
Position Timing - Circuit CAM_IN_SENSOR_B - Refer to the electrical circuit
Over-Advanced diagrams and check intake
(Bank 2) - No sub Engine oil pressure too low valve solenoid 2 sensor circuit
type information Intake valve solenoid 2 circuit short for short circuit to ground, open
circuit to ground, open circuit, high circuit, high resistance
resistance Check and install a new intake
Intake valve solenoid 2 failure valve solenoid 2 sensor as
Timing chains stretched beyond required
allowable limits Check service history /mileage
Check and install new timing
chains as required
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P052D- Cold Start Intake NOTE: Check engine oil level and top
00 (A) Camshaft up as required
Position Timing - Circuit CAM_IN_SENSOR_B - Refer to the electrical circuit
Over-Retarded diagrams and check intake
(Bank 2) - No sub Engine oil pressure too low valve solenoid 2 sensor circuit
type information Intake valve solenoid 2 circuit short for short circuit to ground, open
circuit to ground, open circuit, high circuit, high resistance
resistance Check and install a new intake
Intake valve solenoid 2 failure valve solenoid 2 sensor as
Timing chains stretched beyond required
allowable limits Check service history /mileage
Check and install new timing
chains as required
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P054A- Cold Start Exhaust NOTE: Check engine oil level and top
00 (B) Camshaft up as required
Position Timing - Circuit CAM_EX_SENSOR_A - Refer to the electrical circuit
Over-Advanced diagrams and check exhaust
(Bank 1) - No sub Engine oil pressure too low valve solenoid 1 sensor circuit
type information Exhaust valve solenoid 1 circuit short for short circuit to ground, open
circuit to ground, open circuit, high circuit, high resistance
resistance Check and install a new exhaust
Exhaust valve solenoid 1 failure valve solenoid 1 sensor as
Timing chains stretched beyond required
allowable limits Check service history /mileage
Check and install new timing
chains as required
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P054B- Cold Start Exhaust NOTE: Check engine oil level and top
00 (B) Camshaft up as required
Position Timing - Circuit CAM_EX_SENSOR_A - Refer to the electrical circuit
Over-Retarded diagrams and check exhaust
(Bank 1) - No sub Engine oil pressure too low valve solenoid 1 sensor circuit
type information Exhaust valve solenoid 1 circuit short for short circuit to ground, open
circuit to ground, open circuit, high circuit, high resistance
resistance Check and install a new exhaust
Exhaust valve solenoid 1 failure valve solenoid 1 sensor as
Timing chains stretched beyond required
allowable limits Check service history /mileage
Check and install new timing
chains as required
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P054C- Cold Start Exhaust NOTE: Check engine oil level and top
00 (B) Camshaft up as required
Position Timing - Circuit CAM_EX_SENSOR_B - Refer to the electrical circuit
Over-Advanced diagrams and check exhaust
(Bank 2) - No sub Engine oil pressure too low valve solenoid 2 sensor circuit
type information Exhaust valve solenoid 2 circuit short for short circuit to ground, open
circuit to ground, open circuit, high circuit, high resistance
resistance Check and install a new exhaust
Exhaust valve solenoid 2 failure valve solenoid 2 sensor as
Timing chains stretched beyond required
allowable limits Check service history /mileage
Check and install new timing
chains as required
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P054D- Cold Start Exhaust NOTE: Check engine oil level and top
00 (B) Camshaft up as required
Position Timing - Circuit CAM_EX_SENSOR_B - Refer to the electrical circuit
Over-Retarded diagrams and check exhaust
(Bank 2) - No sub Engine oil pressure too low valve solenoid 2 sensor circuit
type information Exhaust valve solenoid 2 circuit short for short circuit to ground, open
circuit to ground, open circuit, high circuit, high resistance
resistance Check and install a new exhaust
Exhaust valve solenoid 2 failure valve solenoid 2 sensor as
Timing chains stretched beyond required
allowable limits Check service history /mileage
Check and install new timing
chains as required
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0560- System Voltage - NOTE: Refer to the electrical circuit


13 Circuit open diagrams and check engine
- Circuit BATTERY - control module power supply
circuit for open circuit
Engine control module power supply Refer to the electrical circuit
circuit, open circuit diagrams and check engine
Engine control module battery monitor control module battery monitor
disconnected circuit for open circuit

P0562- System Voltage NOTE: Refer to the electrical circuit


00 Low - No sub type diagrams and check battery
information - Circuit BATTERY - circuit for high resistance
Refer to the electrical circuit
Battery circuit high resistance diagrams and check generator
Generator circuit open circuit, high circuit for open circuit, high
resistance resistance
Generator failure Check and install a new
generator as required. Refer to
the warranty policy and
procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0563- System Voltage NOTE: Refer to the electrical circuit


00 High - No sub type diagrams and check battery
information - Circuit BATTERY - circuit for high resistance
Check and install a new
Battery circuit high resistance generator as required. Refer to
Generator over charging the warranty policy and
procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0572- Brake Switch A NOTE: Refer to the electrical circuit


17 Circuit Low - diagrams and check brake
Circuit voltage - Circuit BRAKE_SW - switch 2 circuit for short circuit
above threshold to ground
Brake switch 2 sense circuit short Check brake switch is correctly
circuit to ground installed and adjusted
Brake switch incorrectly Ensure customer is not driving
installed/adjusted with foot resting on brake pedal
Customer is driving with foot resting Check and install a new brake
on brake pedal switch as required. Refer to the
Brake switch 2 failure warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P0573- Brake Switch A NOTE: Refer to the electrical circuit


16 Circuit High - diagrams and check brake
Circuit voltage - Circuit BRAKE_SW - switch 1 circuit for open circuit
below threshold Refer to the electrical circuit
Brake switch 1 sense circuit short diagrams and check brake
circuit to ground switch 2 circuit for open circuit
Brake switch 2 sense circuit open Check brake switch is correctly
circuit installed and adjusted
Brake switch incorrectly Ensure customer is not driving
installed/adjusted with foot resting on brake pedal
Customer is driving with foot resting Check and install a new brake
on brake pedal switch as required. Refer to the
Brake switch 2 failure warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P0578- Cruise Control Speed control circuit, output signal Refer to the electrical circuit
00 Multi-Function stuck diagrams and check speed
Input A Circuit Speed control switch stuck control switch circuit for short
Stuck - No sub type circuit to ground
information Check for stuck speed control
switch, install a new switch
pack as required. Refer to the
warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P057B- Brake Pedal Brake pressure signal missing from Check the anti-lock braking
87 Position Sensor anti-lock braking system control system control module for
Circuit module related DTCs and refer to the
Range/Performance relevant DTC index
- Missing message
P0590- Cruise Control Active speed limiter switch stuck Check for active speed limiter
00 Multi-Function DTCs within gear shift module
Input B Circuit Check and install a new gear
Stuck - No sub type shift module as required. Refer
information to the warranty policy and
procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0600- Serial Corrupt engine control module Using the Jaguar Land Rover
49 Communication software approved diagnostic equipment
Link - Internal Engine control module power supply check and install latest relevant
electronic failure fault level of software to the engine
Engine control module damage control module
through water ingress Check engine control module
power supply circuit for open
circuit
Check engine control module
for signs of water ingress
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0601- Internal Control Corrupt engine control module Using the Jaguar Land Rover
43 Module Memory software flash approved diagnostic equipment
Check Sum Error - Engine control module power supply check and install latest relevant
Special memory fault level of software to the engine
failure Engine control module damage control module
through water ingress Check engine control module
power supply circuit for open
circuit
Check engine control module
for signs of water ingress
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0601- Internal Control Corrupt engine control module Using the Jaguar Land Rover
45 Module Memory software flash approved diagnostic equipment
Check Sum Error - Engine control module power supply check and install latest relevant
Program memory fault level of software to the engine
failure Engine control module damage control module
through water ingress Check engine control module
power supply circuit for open
circuit
Check engine control module
for signs of water ingress
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0604- Internal Control Corrupt engine control module Using the Jaguar Land Rover
42 Module Random software flash approved diagnostic equipment
Access Memory Engine control module power supply check and install latest relevant
(RAM) Error - fault level of software to the engine
General memory Engine control module damage control module
failure through water ingress Check engine control module
power supply circuit for open
circuit
Check engine control module
for signs of water ingress
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0604- Internal Control Corrupt engine control module Using the Jaguar Land Rover
43 Module Random software flash approved diagnostic equipment
Access Memory Engine control module power supply check and install latest relevant
(RAM) Error - fault level of software to the engine
Special memory Engine control module damage control module
failure through water ingress Check engine control module
power supply circuit for open
circuit
Check engine control module
for signs of water ingress
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0604- Internal Control Corrupt engine control module Using the Jaguar Land Rover
44 Module Random software flash approved diagnostic equipment
Access Memory Engine control module power supply check and install latest relevant
(RAM) Error - fault level of software to the engine
Data memory Engine control module damage control module
failure through water ingress Check engine control module
power supply circuit for open
circuit
Check engine control module
for signs of water ingress
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0605- Internal Control Corrupt engine control module Using the Jaguar Land Rover
00 Module Read Only software flash approved diagnostic equipment
Memory (ROM) Engine control module power supply check and install latest relevant
Error - No sub type fault level of software to the engine
information Engine control module damage control module
through water ingress Check engine control module
power supply circuit for open
circuit
Check engine control module
for signs of water ingress
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0605- Internal Control Corrupt engine control module Using the Jaguar Land Rover
29 Module Read Only software flash approved diagnostic equipment
Memory (ROM) Engine control module power supply check and install latest relevant
Error - Signal fault level of software to the engine
invalid Engine control module damage control module
through water ingress Check engine control module
power supply circuit for open
circuit
Check engine control module
for signs of water ingress
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0605- Internal Control Corrupt engine control module Using the Jaguar Land Rover
42 Module Read Only software flash approved diagnostic equipment
Memory (ROM) Engine control module power supply check and install latest relevant
Error - General fault level of software to the engine
memory failure Engine control module damage control module
through water ingress Check engine control module
power supply circuit for open
circuit
Check engine control module
for signs of water ingress
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0605- Internal Control Corrupt engine control module Using the Jaguar Land Rover
44 Module Read Only software flash approved diagnostic equipment
Memory (ROM) Engine control module power supply check and install latest relevant
Error - Data fault level of software to the engine
memory failure Engine control module damage control module
through water ingress Check engine control module
power supply circuit for open
circuit
Check engine control module
for signs of water ingress
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0605- Internal Control Corrupt engine control module Using the Jaguar Land Rover
46 Module Read Only software flash approved diagnostic equipment
Memory (ROM) Engine control module power supply check and install latest relevant
Error - Calibration / fault level of software to the engine
parameter memory Engine control module damage control module
failure through water ingress Check engine control module
power supply circuit for open
circuit
Check engine control module
for signs of water ingress
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0605- Internal Control Corrupt engine control module Using the Jaguar Land Rover
48 Module Read Only software flash approved diagnostic equipment
Memory (ROM) Engine control module power supply check and install latest relevant
Error - Supervision fault level of software to the engine
software failure Engine control module damage control module
through water ingress Check engine control module
power supply circuit for open
circuit
Check engine control module
for signs of water ingress
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0605- Internal Control Corrupt engine control module Using the manufacturer
64 Module Read Only software flash approved diagnostic system
Memory (ROM) Engine control module power supply check and install latest relevant
Error - Signal fault level of software to the engine
plausibility failure Engine control module damage control module
through water ingress Check engine control module
power supply circuit for open
circuit
Check engine control module
for signs of water ingress
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0606- Control Module Corrupt engine control module Using the manufacturer
01 Processor - General software flash approved diagnostic system
electrical failure Engine control module power supply check and install latest relevant
fault level of software to the engine
Engine control module damage control module
through water ingress Check engine control module
power supply circuit for open
circuit
Check engine control module
for signs of water ingress
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0606- Control Module Corrupt engine control module Using the manufacturer
04 Processor - System software flash approved diagnostic system
internal failures Engine control module power supply check and install latest relevant
fault level of software to the engine
Engine control module damage control module
through water ingress Check engine control module
power supply circuit for open
circuit
Check engine control module
for signs of water ingress
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0606- Control Module Corrupt engine control module Using the manufacturer
05 Processor - System software flash approved diagnostic system
programming Engine control module power supply check and install latest relevant
failures fault level of software to the engine
Engine control module damage control module
through water ingress Check engine control module
power supply circuit for open
circuit
Check engine control module
for signs of water ingress
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0606- Control Module Corrupt engine control module Using the manufacturer
41 Processor - General software flash approved diagnostic system
checksum failure Engine control module power supply check and install latest relevant
fault level of software to the engine
Engine control module damage control module
through water ingress Check engine control module
power supply circuit for open
circuit
Check engine control module
for signs of water ingress
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0606- Control Module Corrupt engine control module Using the manufacturer
42 Processor - General software flash approved diagnostic system
memory failure Engine control module power supply check and install latest relevant
fault level of software to the engine
Engine control module damage control module
through water ingress Check engine control module
power supply circuit for open
circuit
Check engine control module
for signs of water ingress
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0606- Control Module Corrupt engine control module Using the manufacturer
43 Processor - Special software flash approved diagnostic system
memory failure Engine control module power supply check and install latest relevant
fault level of software to the engine
Engine control module damage control module
through water ingress Check engine control module
power supply circuit for open
circuit
Check engine control module
for signs of water ingress
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0606- Control Module Corrupt engine control module Using the manufacturer
44 Processor - Data software flash approved diagnostic system
memory failure Engine control module power supply check and install latest relevant
fault level of software to the engine
Engine control module damage control module
through water ingress Check engine control module
power supply circuit for open
circuit
Check engine control module
for signs of water ingress
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0606- Control Module Corrupt engine control module Using the manufacturer
47 Processor - software flash approved diagnostic system
Watchdog / safety Engine control module power supply check and install latest relevant
micro controller fault level of software to the engine
failure Engine control module damage control module
through water ingress Check engine control module
power supply circuit for open
circuit
Check engine control module
for signs of water ingress
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0606- Control Module Corrupt engine control module Using the manufacturer
48 Processor - software flash approved diagnostic system
Supervision Engine control module power supply check and install latest relevant
software failure fault level of software to the engine
Engine control module damage control module
through water ingress Check engine control module
power supply circuit for open
circuit
Check engine control module
for signs of water ingress
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0606- Control Module Corrupt engine control module Using the manufacturer
49 Processor - Internal software flash approved diagnostic system
electronic failure Engine control module power supply check and install latest relevant
fault level of software to the engine
Engine control module damage control module
through water ingress Check engine control module
power supply circuit for open
circuit
Check engine control module
for signs of water ingress
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0607- Control Module Corrupt engine control module Using the manufacturer
00 Performance - No software flash approved diagnostic system
sub type Engine control module power supply check and install latest relevant
information fault level of software to the engine
Engine control module damage control module
through water ingress Check engine control module
power supply circuit for open
circuit
Check engine control module
for signs of water ingress
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0610- Control Module Corrupt engine control module Clear the DTC and re-test
43 Vehicle Options software flash Using the manufacturer
Error - Special Corrupt rear junction box software approved diagnostic system
memory failure flash check and install latest relevant
Corrupt central junction box software level of software to the engine
flash control module
Re-configure the rear junction
box using the manufacturer
approved diagnostic system
Re-configure the central
junction box using the
manufacturer approved
diagnostic system

P0615- Starter Relay NOTE: Refer to the electrical circuit


13 Circuit - Circuit diagrams and check starter
open - Circuit STARTER_RELAY_NEG - relay control circuit for open
circuit
Starter relay control circuit open circuit Check and install a new starter
Starter relay failure relay as required. Refer to the
warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P0616- Starter Relay NOTE: Refer to the electrical circuit


11 Circuit Low - diagrams and check starter
Circuit short to - Circuit STARTER_RELAY_NEG - relay control circuit for short
ground circuit to ground
Starter relay control circuit short Check and install a new starter
circuit to ground relay as required. Refer to the
Starter relay failure warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P0617- Starter Relay NOTE: Refer to the electrical circuit


12 Circuit High - diagrams and check starter
Circuit short to - Circuit STARTER_RELAY_NEG - relay control circuit for short
battery circuit to power
Starter relay control circuit short Check and install a new starter
circuit to power relay as required. Refer to the
Starter relay failure warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P061A- Internal Control Manifold air flow sensor(s) failure Check for related DTCs
00 Module Torque Electronic throttle unit failure Check manifold air flow
Performance - No sensors are reading correctly
sub type Check and install a new
information manifold air flow sensor(s) as
required
Check throttle position sensors
are reading the same position
Check throttle body is clear of
any deposits
Check and install a new
electronic throttle unit as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P061A- Internal Control Manifold air flow sensor(s) failure Check for related DTCs
04 Module Torque Electronic throttle unit failure Check manifold air flow
Performance - sensors are reading correctly
System internal Check and install a new
failures manifold air flow sensor(s) as
required
Check throttle position sensors
are reading the same position
Check throttle body is clear of
any deposits
Check and install a new
electronic throttle unit as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P061A- Internal Control Intake system air leak Check for related DTCs
29 Module Torque Manifold air flow sensor(s) failure Check intake air system for
Performance - Throttle position sensors are reading leaks
Signal invalid incorrectly Check manifold air flow
Electronic throttle unit failure sensors are reading correctly
Atmospheric pressure sensor failure Check and install a new air
flow sensor(s) as required
Check throttle position sensors
are reading the same position
Check throttle body is clear of
any deposits
Check and install a new
electronic throttle unit as
required
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component
P061A- Internal Control Intake system air leak Check for related DTCs
64 Module Torque Manifold air flow sensor(s) failure Check intake air system for
Performance - leaks and is correctly installed
Signal plausibility Check manifold air flow
failure sensors are reading correctly
Check and install a new
manifold air flow sensor(s) as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P061B- Internal Control Intake system air leak Check intake air system for
62 Module Torque Engine breather system leak leaks
Calculation Manifold air flow sensor failure Check engine breather system
Performance - Electronic throttle unit failure for leaks
Signal compare Throttle position sensors are reading Check throttle position sensors
failure incorrectly are reading the same position
Atmospheric pressure sensor failure Check and install a new
manifold air flow sensor as
required
Check and install a new
electronic throttle unit as
required
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0620- Generator Control NOTE: Check for good/clean contact at


01 Circuit - General generator B+ and battery
electrical failure - Circuit LIN_A - terminal connectors
Refer to the electrical circuit
Generator B+ or battery terminal diagrams and check charging
disconnected/poor connection circuit for short circuit, open
Charging circuit short, open circuit circuit
Generator failure Clear DTC and repeat
automated diagnostic procedure
using the manufacturer
approved diagnostic system
If DTC remains, check and
install a new generator as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0627- Fuel Pump A Fuel pump not operating when Using the Jaguar Land Rover
00 Control Circuit / requested approved diagnostic equipment,
Open - No sub type Connector is disconnected, connector perform routine - Inline
information pin is backed out, connector pin diagnostic unit 2 non-intrusive
corrosion test - Low pressure fuel pump
Fuel pump driver module circuit short Inspect connectors for signs of
circuit to ground, short circuit to water ingress, and pins for
power, open circuit, high resistance damage and/or corrosion
Refer to the electrical circuit
diagrams and check the fuel
pump driver module circuit for
short circuit to ground, short
circuit to power, open circuit,
high resistance

P062A- Fuel Pump A Invalid fuel pump duty requested by Refer to the electrical circuit
00 Control Circuit the engine control module diagrams and check the fuel
Range/Performance pump driver module circuit for
- No sub type short circuit to ground, short
information circuit to power, open circuit,
high resistance
Using the Jaguar Land Rover
approved diagnostic equipment,
perform routine - Inline
diagnostic unit 2 non-intrusive
test - Low pressure fuel pump

P0630- VIN Not Car configuration file to CAN VIN Using the manufacturer
00 Programmed or mismatch approved diagnostic system
Incompatible - New engine control module fitted and check and install latest relevant
ECM/PCM - No incorrectly configured level of software to the engine
sub type New central junction box fitted and control module, clear DTC and
information incorrectly configured re-test
Re-configure the central
junction box using the
manufacturer approved
diagnostic system, clear DTC
and re-test

P0634- PCM / ECM/ TCM Engine control module internal Clear the DTC. With the
22 Internal temperature too high ignition off, wait 10 minutes
Temperature Too and re-check DTC
High - Signal Check the engine control
amplitude > module does not have
maximum additional external covering or
obstructions which may cause
overheating
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0634- PCM / ECM / Engine control module internal Clear the DTC. With the
4B TCM Internal temperature too high ignition off, wait 10 minutes
Temperature A Too and re-check DTC
High - Over Check the engine control
temperature module does not have
additional external covering or
obstructions which may cause
overheating
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0642- Sensor Reference NOTE: Refer to the electrical circuit


00 Voltage A Circuit diagrams and check 5V supply
Low - No sub type - Circuit SENSOR_5V_SUPPLY - circuit for short circuit to
information ground open circuit, high
Short circuit to power of a 5V output resistance, terminal damage or
pin, either in the harness, or a corrosion
connector Check engine control module
Internal short circuit in a faulty for sensor related DTCs and
component refer to the relevant DTC index

P0643- Sensor Reference NOTE: Refer to the electrical circuit


00 Voltage A Circuit diagrams and check 5V supply
High - No sub type - Circuit SENSOR_5V_SUPPLY - circuit for short circuit to power
information open circuit, high resistance,
Short circuit to ground of a 5V output terminal damage or corrosion
pin, either in the harness, or a Check engine control module
connector for sensor related DTCs and
Internal short circuit in a faulty refer to the relevant DTC index
component

P0657- Actuator Supply NOTES: Refer to the electrical circuit


13 Voltage A Circuit / diagrams and check intake
Open - Circuit open Jaguar - Circuit IMTV - manifold tuning solenoid circuit
for open circuit
LR - Circuit MANIFOLD TUNING
VALVE -

Intake manifold tuning solenoid


circuit, open circuit

P0658- Actuator Supply NOTES: Refer to the electrical circuit


11 Voltage A Circuit diagrams and check intake
Low - Circuit short Jaguar - Circuit IMTV - manifold tuning solenoid circuit
to ground for short circuit to ground
LR - Circuit MANIFOLD TUNING
VALVE -

Intake manifold tuning solenoid


circuit, short circuit to ground

P0659- Actuator Supply NOTES: Refer to the electrical circuit


12 Voltage A Circuit diagrams and check intake
High - Circuit short Jaguar - Circuit IMTV - manifold tuning solenoid circuit
to battery for short circuit to power
LR - Circuit MANIFOLD TUNING
VALVE -

Intake manifold tuning solenoid


circuit, short circuit to power

P065B- Generator Control NOTE: Check for good/clean contact at


16 Circuit generator B+ and battery
Range/Performance - Circuit LIN_A - terminal connectors
- Circuit voltage Refer to the electrical circuit
below threshold Generator B+ or battery terminal diagrams and check charging
disconnected/poor connection circuit for short circuit, open
Charging circuit short, open circuit circuit
Generator failure Ensure the battery is in a fully
Battery failure charged and serviceable
condition. Refer to the battery
care manual and the relevant
sections of the workshop
manual
Clear DTC and repeat
automated diagnostic procedure
using the manufacturer
approved diagnostic system. If
DTC remains, check and install
a new generator as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P065B- Generator Control NOTE: Check for good/clean contact at


17 Circuit generator B+ and battery
Range/Performance - Circuit LIN_A - terminal connectors
- Circuit voltage Refer to the electrical circuit
above threshold Charging circuit short circuit to power diagrams and check charging
Generator failure circuit for short circuit, open
Battery failure circuit
Ensure the battery is in a fully
charged and serviceable
condition. Refer to the battery
care manual and the relevant
sections of the workshop
manual
Clear DTC and repeat
automated diagnostic procedure
using the manufacturer
approved diagnostic system. If
DTC remains, check and install
a new generator as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P065C- Generator NOTE: Check front end accessory belt


00 Mechanical for condition/contamination
Performance - No - Circuit LIN_A - and correct tension
sub type Check generator pulley for
information Poor front end accessory belt tension failure
Generator pulley loose/failure Clear DTC and repeat
Generator failure automated diagnostic procedure
using manufacturer approved
diagnostic system
If DTC remains check and
install a new generator as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0660- Intake Manifold NOTES: Refer to the electrical circuit


13 Tuning Valve diagrams and check intake
Control Circuit - Circuit IMTV - manifold tuning valve circuit
Low - Bank 1 - for open circuit
Circuit open LR - Circuit MANIFOLD TUNING
VALVE -

Intake manifold tuning valve circuit


open circuit

P0661- Intake Manifold NOTES: Refer to the electrical circuit


11 Tuning Valve diagrams and check intake
Control Circuit - Circuit IMTV - manifold tuning valve circuit
Low - Bank 1 - for short circuit to ground
Circuit short to LR - Circuit MANIFOLD TUNING
ground VALVE -

Intake manifold tuning valve circuit


short circuit to ground

P0662- Intake Manifold NOTES: Refer to the electrical circuit


12 Tuning Valve diagrams and check manifold
Control Circuit - Circuit IMTV - tuning valve circuit for short
Low - Bank 1 - circuit to power
Circuit short to LR - Circuit MANIFOLD TUNING
battery VALVE -

Intake manifold tuning valve circuit


short circuit to power

P0668- PCM / ECM / Engine control module internal Check and install a new engine
00 TCM Internal temperature sensor failure control module as required.
Temperature Refer to the warranty policy
Sensor A Circuit and procedures manual, or
Low - No sub type determine if any prior approval
information programme is in operation,
prior to the installation of a new
module/component

P0669- PCM / ECM / Engine control module internal Check and install a new engine
00 TCM Internal temperature sensor failure control module as required.
Temperature Refer to the warranty policy
Sensor A Circuit and procedures manual, or
High - No sub type determine if any prior approval
information programme is in operation,
prior to the installation of a new
module/component

P0687- ECM/PCM Power NOTE: Refer to the electrical circuit


73 Relay Control diagrams and check engine
Circuit High - - Circuit EMS_MAIN_RLY - control module relay circuit for
Actuator stuck short circuit to power
closed Engine control module relay circuit Check and install a new engine
short circuit to power control module relay as
Engine control module relay failure required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P0695- Fan 3 Control NOTE: Refer to the electrical circuit


00 Circuit Low - No diagrams and check E-Box
sub type - Circuit E_BOX_FAN - cooling fan circuit for short
information circuit to ground
E-Box cooling fan circuit short circuit Check and install a new E-Box
to ground cooling fan as required. Refer
E-Box cooling fan failure to the warranty policy and
procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0696- Fan 3 Control NOTE: Refer to the electrical circuit


12 Circuit High - diagrams and check E-Box
Circuit short to - Circuit E_BOX_FAN - cooling fan circuit for short
battery circuit to power
E-Box cooling fan circuit short circuit Check and install a new E-Box
to power cooling fan as required. Refer
E-Box cooling fan failure to the warranty policy and
procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0696- Fan 3 Control NOTE: Refer to the electrical circuit


13 Circuit High - diagrams and check E-Box
Circuit open - Circuit E_BOX_FAN - cooling fan circuit for open
circuit
E-Box cooling fan circuit open circuit Check and install a new E-Box
E-Box cooling fan failure cooling fan as required. Refer
to the warranty policy and
procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P0721- Output Shaft Speed Transmission control module has Check transmission control
85 Sensor Circuit reported a fault in the shaft speed module for related DTCs and
Range/Performance signal refer to relevant DTC index
- Signal above
allowable range
P0721- Output Shaft Speed Transmission control module has taken Check transmission control
86 Sensor Circuit to 8 seconds or longer to change range module for related DTCs and
Range/Performance refer to relevant DTC index
- Signal invalid
P0724- Brake Switch B NOTE: Refer to the electrical circuit
17 Circuit High - diagrams and check brake
Circuit voltage - Circuit BRAKE_SW - switch 1 circuit for short circuit
above threshold to power
Brake switch 1 sense circuit short Check brake switch is correctly
circuit to power installed and adjusted
Brake switch incorrectly Ensure customer is not driving
installed/adjusted with foot resting on brake pedal
Customer is driving with foot resting Check and install a new brake
on brake pedal switch as required. Refer to the
Brake switch 1 failure warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P0850- Park / Neutral NOTE: Check gear shift module for


86 Switch Input related DTCs and refer to
Circuit - Signal - Circuit PN_SW - relevant DTC index
invalid Refer to the electrical circuit
Intermittent fault on Park/Neutral diagrams and check
signal from gear shift module Park/Neutral switch input
CAN network failure between gear circuit for short circuit to
shift module and engine control ground, short circuit to power,
module open circuit
Using the manufacturer
approved diagnostic system,
complete a CAN network
integrity test

P0850- Park / Neutral NOTE: Check gear shift module for


8F Switch Input related DTCs and refer to
Circuit - Erratic - Circuit PN_SW - relevant DTC index
Refer to the electrical circuit
Intermittent fault on Park/Neutral diagrams and check
signal from gear shift module Park/Neutral switch input
CAN network failure between gear circuit for short circuit to
shift module and engine control ground, short circuit to power,
module open circuit
Using the manufacturer
approved diagnostic system,
complete a CAN network
integrity test

P0851- Park / Neutral NOTE: Refer to the electrical circuit


14 Switch Input diagrams and check
Circuit Low - - Circuit PN_SW - park/neutral switch input circuit
Circuit short to for short circuit to ground, open
ground or open Park/Neutral switch input circuit short circuit
circuit to ground, open circuit

P0852- Park / Neutral NOTE: Refer to the electrical circuit


12 Switch Input diagrams and check
Circuit Low - - Circuit PN_SW - park/neutral switch input circuit
Circuit short to for short circuit to power
battery Park/Neutral switch input circuit short
circuit to power

P0A1A- Generator Control NOTE: Check for good/clean contact at


87 Module - Missing generator and engine control
message - Circuit LIN_A - module LIN circuit
connectors/pins
Generator to engine control module Refer to the electrical circuit
LIN circuit open circuit diagrams and check generator
circuit for open circuit
Check for engine control
module hardware DTCs and
refer to relevant DTC index
Clear DTCs and repeat
automated diagnostic procedure
using the manufacturer
approved diagnostic system

P0A1A- Generator Control NOTE: Check for good/clean contact at


88 Module - Bus off generator and engine control
- Circuit LIN_A - module LIN circuit
connectors/pins
Generator to engine control module Refer to the electrical circuit
LIN circuit open circuit diagrams and check generator
circuit for open circuit
Check for engine control
module hardware DTCs and
refer to relevant DTC index
Clear DTCs and repeat
automated diagnostic procedure
using the manufacturer
approved diagnostic system

P0A3B- Generator Over Cooling fan not operating Check for correct cooling fan
00 Temperature - No Coolant level low operation
sub type Check coolant level. Clear DTC
information and re-test
P0A3B- Generator Over Cooling fan not operating Check for correct cooling fan
68 Temperature - Coolant level low operation
Event information Check coolant level. Clear DTC
and re-test

P115D- Mass Air Flow NOTE: Using the manufacturer


00 Circuit Offset - No approved diagnostic system
sub type - Circuit MAF_SENSOR_A - check datalogger signal, Mass
information MAF_SENSOR_B - Air Flow Sensor 2 Voltage
(0x0503)
NOTE: Check air cleaner for blockage
Check air intake system for
Customer likely to report hesitation. leaks
Check engine breather system
Air cleaner blocked for blockages
Air intake leak Check for carbon build up on
Engine breather blocked throttle blade
Air intake blockage Check for related mass air flow
Carbon build up on throttle blade DTCs P0102 or P0103
Mass air flow sensor circuit, high Refer to the electrical circuit
resistance diagrams and check mass air
Blocked catalyst(s) flow sensor circuit for high
Mass air flow sensor failure resistance
Check and install a new mass
air flow sensor as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P1315- Persistent Misfire - Engine control module to ignition coil Check for cylinder mis-fire,
00 No sub type primary circuit fault (cylinder misfire ignition and injector DTCs and
information detected DTC also flagged) refer to the DTC index
Fuel injector circuit fault(s) (injector Refer to the electrical circuit
DTCs also flagged) diagrams and check ignition
Fuel delivery pressure low coil circuit for short circuit to
Spark plug failure/fouled/incorrect gap ground, short circuit to power,
Ignition coil failure open circuit
Cylinder compression low Check for fuel system failure
Exhaust system blockage Check and install a new spark
plug(s) as required
Check and install a new
ignition coil as required
Carry out cylinder compression
tests
Check exhaust system for
blockage
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component
P1316- Injector Driver Engine control module to ignition coil Check for cylinder mis-fire,
00 Module Codes primary circuit fault (cylinder misfire ignition and injector DTCs and
Detected - No sub detected DTC also flagged) refer to the DTC index
type information Fuel injector circuit fault(s) (injector Refer to the electrical circuit
DTCs also flagged) diagrams and check ignition
Fuel delivery pressure low coil circuit for short circuit to
Spark plug failure/fouled/incorrect gap ground, short circuit to power,
Ignition coil failure open circuit
Cylinder compression low Check for fuel system failure
Exhaust system blockage Check and install a new spark
plug(s) as required
Check and install a new
ignition coil as required
Carry out cylinder compression
tests
Check exhaust system for
blockage
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P1593- Cruise Control Speed control monitor fault. The Using the manufacturer
64 Monitor Fault - engine control module performs a approved diagnostic system
Signal plausibility independent check of the cruise status check and up-date the car
failure configuration file as required.
Clear the DTC and retest. If the
problem persists, contact dealer
technical support

P1603- EEPROM Corrupt engine control module Using the manufacturer


00 Malfunction - No software flash approved diagnostic system
sub type Engine control module power supply check and install latest relevant
information fault level of software to the engine
Engine control module damage control module
through water ingress Refer to the electrical circuit
diagrams and check engine
control module power supply
circuit for open circuit
Check engine control module
for signs of water ingress
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P2088- A Camshaft NOTE: Refer to the electrical circuit


11 Position Actuator diagrams and check intake
Control Circuit - Circuit VFS_IN_A - valve solenoid 1 for short
Low Bank 1 - circuit to ground
Circuit short to Intake valve solenoid 1 short circuit to
ground ground

P2089- A Camshaft NOTE: Refer to the electrical circuit


12 Position Actuator diagrams and check intake
Control Circuit - Circuit VFS_IN_A - valve solenoid 1 for short
High Bank 1 - circuit to power
Circuit short to Intake valve solenoid 1 short circuit to
battery power

P2090- B Camshaft NOTE: Refer to the electrical circuit


11 Position Actuator diagrams and check exhaust
Control Circuit - Circuit VFS_EX_A - valve solenoid 1 for short
Low Bank 1 - circuit to ground
Circuit short to Exhaust valve solenoid 1 short circuit
ground to ground

P2091- B Camshaft NOTE: Refer to the electrical circuit


12 Position Actuator diagrams and check exhaust
Control Circuit - Circuit VFS_EX_A - valve solenoid 1 for short
High Bank 1 - circuit to power
Circuit short to Exhaust valve solenoid 1 short circuit
battery to power

P2092- A Camshaft NOTE: Refer to the electrical circuit


11 Position Actuator diagrams and check intake
Control Circuit - Circuit VFS_IN_B - valve solenoid 2 for short
Low Bank 2 - circuit to ground
Circuit short to Intake valve solenoid 2 short circuit to
ground ground

P2093- A Camshaft NOTE: Refer to the electrical circuit


12 Position Actuator diagrams and check intake
Control Circuit - Circuit VFS_IN_B - valve solenoid 2 for short
High Bank 2 - circuit to power
Circuit short to Intake valve solenoid 2 short circuit to
battery power

P2094- B Camshaft NOTE: Refer to the electrical circuit


11 Position Actuator diagrams and check exhaust
Control Circuit - Circuit VFS_EX_B - valve solenoid 2 for short
Low Bank 2 - circuit to ground
Circuit short to Exhaust valve solenoid 2 short circuit
ground to ground

P2095- B Camshaft NOTE: Refer to the electrical circuit


12 Position Actuator diagrams and check exhaust
Control Circuit - Circuit VFS_EX_B - valve solenoid 2 for short
High Bank 2 - circuit to power
Circuit short to Exhaust valve solenoid 2 short circuit
battery to power

P2096- Post Catalyst Fuel NOTE: Refer to the electrical circuit


00 Trim System Too diagrams and check post
Lean Bank 1 - No - Circuit HEGO_SENSOR_A - catalyst oxygen sensor - odd,
sub type sensing circuit for short circuit
information Post catalyst oxygen sensor odd, to ground, high resistance, open
sensing circuit short circuit to ground, circuit
high resistance, open circuit Check for air leak between
Air leak between catalyst and exhaust catalyst and exhaust manifold
manifold Check for air leak between the
Air leak between the two oxygen two oxygen sensors
sensors Check and install new post
Post catalyst oxygen sensor odd, catalyst oxygen sensor odd, as
failure required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P2097- Post Catalyst Fuel NOTE: Refer to the electrical circuit


00 Trim System Too diagrams and check post
Rich Bank 1 - No - Circuit HEGO_SENSOR_A - catalyst oxygen sensor - odd,
sub type sensing circuit for short circuit
information Post catalyst oxygen sensor odd, to ground, high resistance, open
sensing circuit short circuit to ground, circuit
high resistance, open circuit Check for air leak between
Air leak between catalyst and exhaust catalyst and exhaust manifold
manifold Check for air leak between the
Air leak between the two oxygen two oxygen sensors
sensors Check and install new post
Post catalyst oxygen sensor odd, catalyst oxygen sensor odd, as
failure required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P2098- Post Catalyst Fuel NOTE: Refer to the electrical circuit


00 Trim System Too diagrams and check post
Lean Bank 2 - No - Circuit HEGO_SENSOR_B - catalyst oxygen sensor even,
sub type sensing circuit for short circuit
information Post catalyst oxygen sensor even, to ground, high resistance, open
sensing circuit short circuit to ground, circuit
high resistance, open circuit Check for air leak between
Air leak between catalyst and exhaust catalyst and exhaust manifold
manifold Check for air leak between the
Air leak between the two oxygen two oxygen sensors
sensors Check and install new post
Post catalyst oxygen sensor even, catalyst oxygen sensor even, as
failure required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P2099- Post Catalyst Fuel NOTE: Refer to the electrical circuit


00 Trim System Too diagrams and check post
- Circuit HEGO_SENSOR_B -
Rich Bank 2 - No catalyst oxygen sensor even,
sub type sensing circuit for short circuit
information Post catalyst oxygen sensor even, to ground, high resistance, open
sensing circuit short circuit to ground, circuit
high resistance, open circuit Check for air leak between
Air leak between catalyst and exhaust catalyst and exhaust manifold
manifold Check for air leak between the
Air leak between the two oxygen two oxygen sensors
sensors Check and install new post
Post catalyst oxygen sensor even, catalyst oxygen sensor even, as
failure required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P2105- Throttle Actuator NOTE: Check for any DTCs relating to


00 Control System - engine control module, throttle
Forced Engine - Circuit THROTTLE_MOTOR_NEG - pedal position sensor, or torque
Shutdown - No sub THROTTLE_MOTOR_POS - faults and refer to the DTC
type information index
Engine speed or torque limitation has
been activated as a result of engine
control module, throttle pedal position
sensor, or torque faults

P2118- Throttle Actuator NOTE: Refer to the electrical circuit


19 Control Motor diagrams and check electronic
Current - Circuit THROTTLE_MOTOR_NEG - throttle unit circuit for short
Range/Performance THROTTLE_MOTOR_POS - circuit to ground, short circuit
- Circuit current to power, high resistance
above threshold Throttle motor control circuit short Refer to the electrical circuit
circuit to ground, short circuit to diagrams and check engine
power, high resistance control module ground circuit
Engine control module ground circuit for faults
fault Make sure throttle blade is
Carbon build-up on throttle blade clean of carbon
Electronic throttle unit failure Check the system is operating
correctly and the DTC does not
return
Check and install a new
electronic throttle unit as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P2119- Throttle Actuator NOTE: Make sure throttle blade is


00 Control Throttle clean of carbon
Body - Circuit THROTTLE_MOTOR_NEG - Refer to the electrical circuit
Range/Performance THROTTLE_MOTOR_POS - diagrams and check engine
- No sub type control module ground circuit
information Carbon build-up on throttle blade for faults
Engine control module ground circuit Check the system is operating
fault correctly and the DTC does not
Electronic throttle unit return spring return
faulty Check and install a new
Electronic throttle unit limp home electronic throttle unit as
spring faulty required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P2119- Throttle Actuator NOTE: Ensure throttle blade is free of


29 Control Throttle any carbon build-up / other
Body - Circuit THROTTLE_MOTOR_NEG - obstructions
Range/Performance THROTTLE_MOTOR_POS - Check the system is operating
- Signal invalid correctly and the DTC does not
Stuck / sticking throttle blade return
Electronic throttle unit failure Check and install a new
electronic throttle unit as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P2119- Throttle Actuator NOTE: Ensure throttle blade is free of


64 Control Throttle any carbon build-up / other
Body - Circuit THROTTLE_MOTOR_NEG - obstructions
Range/Performance THROTTLE_MOTOR_POS - Check the system is operating
- Signal plausibility correctly and the DTC does not
failure Stuck / sticking throttle blade return
Electronic throttle unit failure Check and install a new
electronic throttle unit as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P2122- Throttle/Pedal NOTE: Refer to the electrical circuit


00 Position diagrams and check accelerator
Sensor/Switch D - Circuit pedal unit, accelerator pedal
Circuit Low - No THROTTLE_POSITION_SENSOR_1 - position sensor 1 circuit for
sub type short circuit to ground, open
information Accelerator pedal position sensor 1 circuit
circuit short circuit to ground, open Check accelerator pedal unit,
circuit VREF circuit for open circuit
Accelerator pedal position sensor 1, Clear DTC and repeat
VREF circuit open circuit automated diagnostic procedure
Accelerator pedal position sensor 1
using the manufacturer
failure approved diagnostic system
If DTC remains, check and
install a new accelerator pedal
unit as required. Refer to the
warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P2123- Throttle/Pedal NOTE: Refer to the electrical circuit


00 Position diagrams and check accelerator
Sensor/Switch D - Circuit pedal unit, accelerator pedal
Circuit High - No THROTTLE_POSITION_SENSOR_1 - position sensor 1 circuit for
sub type short circuit to power
information Accelerator pedal position sensor 1 Check accelerator pedal unit,
circuit short circuit to power VREF circuit for open circuit
Accelerator pedal position sensor 1, Clear DTC and repeat
VREF circuit open circuit automated diagnostic procedure
Accelerator pedal position sensor 1 using the manufacturer
failure approved diagnostic system
If DTC remains, check and
install a new accelerator pedal
unit as required. Refer to the
warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P2127- Throttle/Pedal NOTE: Refer to the electrical circuit


00 Position diagrams and check accelerator
Sensor/Switch E - Circuit pedal unit, accelerator pedal
Circuit Low - No THROTTLE_POSITION_SENSOR_2 - position sensor 2 circuit for
sub type short circuit to ground, open
information Accelerator pedal position sensor 2 circuit
circuit short circuit to ground, open Check accelerator pedal unit,
circuit VREF circuit for open circuit
Accelerator pedal position sensor 2, Clear DTC and repeat
VREF circuit open circuit automated diagnostic procedure
Accelerator pedal position sensor 2 using the manufacturer
failure approved diagnostic system
If DTC remains, check and
install a new accelerator pedal
unit as required. Refer to the
warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P2128- Throttle/Pedal NOTE: Refer to the electrical circuit


00 Position diagrams and check accelerator
Sensor/Switch E - Circuit pedal unit, accelerator pedal
Circuit High - No THROTTLE_POSITION_SENSOR_2 - position sensor 2 circuit for
sub type short circuit to power
information Accelerator pedal position sensor 2 Check accelerator pedal unit,
circuit short circuit to power VREF circuit for open circuit
Accelerator pedal position sensor 2, Clear DTC and repeat
VREF circuit open circuit automated diagnostic procedure
Accelerator pedal position sensor 2 using the manufacturer
failure approved diagnostic system
If DTC remains, check and
install a new accelerator pedal
unit as required. Refer to the
warranty policy and procedures
manual, or determine if any
prior approval programme is in
operation, prior to the
installation of a new
module/component

P2135- Throttle/Pedal Throttle pedal position sensor circuit 1 Refer to the electrical circuit
00 Position and 2 short circuit to ground, short diagrams and check throttle
Sensor/Switch A / circuit to power, open circuit pedal position sensor circuit 1
B Voltage and 2 for short circuit to
Correlation - No ground, short circuit to power,
sub type open circuit
information
P2135- Throttle/Pedal Throttle pedal position sensor circuit 1 Refer to the electrical circuit
09 Position and 2 short circuit to ground, short diagrams and check throttle
Sensor/Switch A / circuit to power, open circuit pedal position sensor circuit 1
B Voltage and 2 for short circuit to
Correlation - ground, short circuit to power,
Component open circuit
Failures
P2138- Throttle/Pedal Accelerator pedal position sensor Refer to the electrical circuit
64 Position circuit 1 and 2 short circuit to ground, diagrams and check accelerator
Sensor/Switch D / short circuit to power, open circuit pedal position sensor circuit 1
E Voltage and 2 for short circuit to
Correlation - No ground, short circuit to power,
sub type open circuit
information
P2183- Engine Coolant NOTE: Refer to the electrical circuit
23 Temperature diagrams and check engine
Sensor 2 Circuit - Circuit COOLANT_TEMP_SENSOR_2 - coolant temperature sensor 2
Range/Performance circuit for high resistance, open
- Signal stuck low Engine coolant temperature sensor 2 circuit
circuit high resistance, open circuit Check and install a new engine
Engine coolant temperature sensor 2 coolant temperature sensor 2 as
failure required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P2183- Engine Coolant NOTE: Refer to the electrical circuit


24 Temperature diagrams and check engine
Sensor 2 Circuit - Circuit COOLANT_TEMP_SENSOR_2 - coolant temperature sensor 2
Range/Performance circuit for short circuit to power
- Signal stuck high Engine coolant temperature sensor 2 Check and install a new engine
circuit short circuit to power coolant temperature sensor 2 as
Engine coolant temperature sensor 2 required. Refer to the warranty
failure policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P2183- Engine Coolant NOTE: Refer to the electrical circuit


29 Temperature diagrams and check engine
Sensor 2 Circuit - Circuit COOLANT_TEMP_SENSOR_2 - coolant temperature sensor 2
Range/Performance circuit for high resistance, open
- Signal invalid Engine coolant temperature sensor 2 circuit, short circuit to ground,
circuit high resistance, open circuit, short circuit to power
short circuit to ground, short circuit to Check and install a new engine
power coolant temperature sensor 2 as
Engine coolant temperature sensor 2 required. Refer to the warranty
failure policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P2184- Engine Coolant NOTE: Refer to the electrical circuit


16 Temperature diagrams and check engine
Sensor 2 Circuit - Circuit COOLANT_TEMP_SENSOR_2 - coolant temperature sensor 2
Low - Circuit circuit for high resistance, open
voltage below Engine coolant temperature sensor 2 circuit, short circuit to ground
threshold circuit high resistance, open circuit, Check and install a new engine
short circuit to ground coolant temperature sensor 2 as
Engine coolant temperature sensor 2 required. Refer to the warranty
failure policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P2185- Engine Coolant NOTE: Clear the DTC and re-test


17 Temperature Refer to the electrical circuit
Sensor 2 Circuit - Circuit COOLANT_TEMP_SENSOR_2 - diagrams and check engine
High - Circuit coolant temperature sensor 2
voltage above Ignition turned on with an ambient circuit for short circuit to power
threshold temperature of below -40c Check and install a new engine
Engine coolant temperature sensor 2 coolant temperature sensor 2 as
circuit short circuit to power required. Refer to the warranty
Engine coolant temperature sensor 2 policy and procedures manual,
failure or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P219A- Bank 1 Air-Fuel NOTE: Using the manufacturer


00 Ratio Imbalance - approved diagnostic system
No sub type Post catalyst oxygen sensor-odd & Pre check the engine control
information catalyst oxygen sensor-odd module for oxygen sensor
related DTCs and refer to the
Other oxygen sensor related DTCs relevant DTC index. Record
Air leak in the exhaust system between any available freeze frame data
post catalyst oxygen sensor-odd and Check for air leaks in the
catalyst exhaust system between post
Air leak in the exhaust system between catalyst oxygen sensor-odd and
catalyst and exhaust manifold flange catalyst
Air leak in the exhaust system between Check for air leaks in the
pre catalyst oxygen sensor-odd and exhaust system between
post catalyst oxygen sensor-odd catalyst and exhaust manifold
Air leak around pre catalyst oxygen flange
sensor-odd Check for air leaks in the
Air leaks within the intake system exhaust system between pre
Air leak around fuel injector(s) bank 1 catalyst oxygen sensor-odd and
Air leak around spark plug(s) bank 1 post catalyst oxygen sensor-odd
Low fuel pressure, fuel injector(s) leak, Check for air leaks around pre
fuel system leak bank 1 catalyst oxygen sensor-odd
Camshaft position actuator sticking Check for air leaks within the
Airpath blockage between throttle intake system
butterfly and inlet poppet valve Check for air leak around fuel
Post catalyst oxygen sensor-odd failure injector(s) bank 1
Cylinder head gasket failure Check for air leak around spark
plug(s) bank 1
Check for low fuel pressure,
fuel injector(s) leak, fuel
system leak bank 1
Check for camshaft position
actuator sticking
Check for airpath blockage
between throttle butterfly and
inlet poppet valve
Carry out cylinder compression
check. Record the results
Check and install a post catalyst
oxygen sensor-odd as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component
Using the manufacturer
approved diagnostic system
clear DTC and retest

P219B- Bank 2 Air-Fuel NOTE: Using the manufacturer


00 Ratio Imbalance - approved diagnostic system
No sub type Post catalyst oxygen sensor-even & Pre check the engine control
information catalyst oxygen sensor-even module for oxygen sensor
related DTCs and refer to the
Other oxygen sensor related DTCs relevant DTC index. Record
Air leak in the exhaust system between any available freeze frame data
post catalyst oxygen sensor-even and Check for air leaks in the
catalyst exhaust system between post
Air leak in the exhaust system between catalyst oxygen sensor-even
catalyst and exhaust manifold flange and catalyst
Air leak in the exhaust system between Check for air leaks in the
pre catalyst oxygen sensor-even and exhaust system between
post catalyst oxygen sensor-even catalyst and exhaust manifold
Air leak around pre catalyst oxygen flange
sensor-even Check for air leaks in the
Air leaks within the intake system exhaust system between pre
Air leak around fuel injector(s) bank 2 catalyst oxygen sensor-even
Air leak around spark plug(s) bank 2 and post catalyst oxygen
Low fuel pressure, fuel injector(s) leak, sensor-even
fuel system leak bank 2 Check for air leaks around pre
Camshaft position actuator sticking catalyst oxygen sensor-even
Airpath blockage between throttle Check for air leaks within the
butterfly and inlet poppet valve intake system
Post catalyst oxygen sensor-even Check for air leak around fuel
failure injector(s) bank 2
Cylinder head gasket failure Check for air leak around spark
plug(s) bank 2
Check for low fuel pressure,
fuel injector(s) leak, fuel
system leak bank 2
Check for camshaft position
actuator sticking
Check for airpath blockage
between throttle butterfly and
inlet poppet valve
Carry out cylinder compression
check. Record the results
Check and install a post catalyst
oxygen sensor-even as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component
Using the manufacturer
approved diagnostic system
clear DTC and retest

P2228- Barometric Barometric pressure sensor Using the manufacturer


00 Pressure Circuit failure(internal engine control module approved diagnostic system
Low - No sub type failure) check datalogger signal,
information Barometric Pressure Sensor
Voltage (0x035A)
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P2229- Barometric Barometric pressure sensor Using the manufacturer


00 Pressure Circuit failure(internal engine control module approved diagnostic system
Low - No sub type failure) check datalogger signal,
information Barometric Pressure Sensor
Voltage (0x035A)
Check and install a new engine
control module as required.
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

P2279- Intake Air System Part load breather pipe disconnected Check for related DTCs
00 Leak - No sub type Brake vacuum pipe disconnected Check part load breather pipe
information Excessive intake air leak for leaks or disconnected
Check brake vacuum pipe for
leaks or disconnected
Check intake air system for
leaks

P2300- Ignition Coil A NOTE: Refer to the electrical circuit


11 Primary Control diagrams and check ignition
Circuit Low - - Circuit IGNITION_1A - coil 1 circuit for short circuit to
Circuit short to ground
ground Ignition coil 1 circuit short circuit to
ground

P2301- Ignition Coil A NOTE: Refer to the electrical circuit


12 Primary Control diagrams and check ignition
Circuit High - - Circuit IGNITION_1A - coil 1 circuit for short circuit to
Circuit short to power
battery Ignition coil 1 circuit short circuit to
power

P2303- Ignition Coil B NOTE: Refer to the electrical circuit


11 Primary Control diagrams and check ignition
Circuit Low - - Circuit IGNITION_1B - coil 2 circuit for short circuit to
Circuit short to ground
ground Ignition coil 2 circuit short circuit to
ground

P2304- Ignition Coil B NOTE: Refer to the electrical circuit


12 Primary Control diagrams and check ignition
Circuit High - - Circuit IGNITION_1B - coil 2 circuit for short circuit to
Circuit short to power
battery Ignition coil 2 circuit short circuit to
power

P2306- Ignition Coil C NOTE: Refer to the electrical circuit


11 Primary Control diagrams and check ignition
Circuit Low - - Circuit IGNITION_2A - coil 3 circuit for short circuit to
Circuit short to ground
ground Ignition coil 3 circuit short circuit to
ground

P2307- Ignition Coil C NOTE: Refer to the electrical circuit


12 Primary Control diagrams and check ignition
Circuit High - - Circuit IGNITION_2A - coil 3 circuit for short circuit to
Circuit short to power
battery Ignition coil 3 circuit short circuit to
power

P2309- Ignition Coil D NOTE: Refer to the electrical circuit


11 Primary Control diagrams and check ignition
Circuit Low - - Circuit IGNITION_2B - coil 4 circuit for short circuit to
Circuit short to ground
ground Ignition coil 4 circuit short circuit to
ground

P2310- Ignition Coil D NOTE: Refer to the electrical circuit


12 Primary Control diagrams and check ignition
Circuit High - - Circuit IGNITION_2B - coil 4 circuit for short circuit to
Circuit short to power
battery Ignition coil 4 circuit short circuit to
power

P2312- Ignition Coil E NOTE: Refer to the electrical circuit


11 Primary Control diagrams and check ignition
Circuit Low - - Circuit IGNITION_3A - coil 5 circuit for short circuit to
Circuit short to ground
ground Ignition coil 5 circuit short circuit to
ground

P2313- Ignition Coil E NOTE: Refer to the electrical circuit


12 Primary Control diagrams and check ignition
Circuit High - - Circuit IGNITION_3A - coil 5 circuit for short circuit to
Circuit short to power
battery Ignition coil 5 circuit short circuit to
power

P2315- Ignition Coil F NOTE: Refer to the electrical circuit


11 Primary Control diagrams and check ignition
Circuit Low - - Circuit IGNITION_3B - coil 6 circuit for short circuit to
Circuit short to ground
ground Ignition coil 6 circuit short circuit to
ground

P2316- Ignition Coil F NOTE: Refer to the electrical circuit


12 Primary Control diagrams and check ignition
Circuit High - - Circuit IGNITION_3B - coil 6 circuit for short circuit to
Circuit short to power
battery Ignition coil 6 circuit short circuit to
power

P2318- Ignition Coil G NOTE: Refer to the electrical circuit


11 Primary Control diagrams and check ignition
Circuit Low - - Circuit IGNITION_4A - coil 7 circuit for short circuit to
Circuit short to ground
ground Ignition coil 7 circuit short circuit to
ground
P2319- Ignition Coil G NOTE: Refer to the electrical circuit
12 Primary Control diagrams and check ignition
Circuit High - - Circuit IGNITION_4A - coil 7 circuit for short circuit to
Circuit short to power
battery Ignition coil 7 circuit short circuit to
power

P2321- Ignition Coil H NOTE: Refer to the electrical circuit


11 Primary Control diagrams and check ignition
Circuit Low - - Circuit IGNITION_4B - coil 8 circuit for short circuit to
Circuit short to ground
ground Ignition coil 8 circuit short circuit to
ground

P2322- Ignition Coil H NOTE: Refer to the electrical circuit


12 Primary Control diagrams and check ignition
Circuit High - - Circuit IGNITION_4B - coil 8 circuit for short circuit to
Circuit short to power
battery Ignition coil 8 circuit short circuit to
power

P2401- Evaporative Diagnostic module tank leakage pump NOTES:


00 Emission System circuit short circuit to ground
Leak Detection If purge valve related DTCs are
Pump Control also set, perform the relevant
Circuit Low - No corrective action(s) first.
sub type
information It is not possible to replicate the
failure event as certain entry
conditions must be satisfied
(for more information, refer to
section 303-13: Evaporative
Emissions / Description and
Operation). To verify the
customer concern, perform
routine Evaporative System
Diagnostic Check and re-read
DTCs.

Refer to the electrical circuit


diagrams and check the
diagnostic module tank leakage
pump circuit for short circuit to
ground

P2402- Evaporative Diagnostic module tank leakage pump NOTES:


00 Emission System circuit short circuit to power
Leak Detection If purge valve related DTCs are
Pump Control also set, perform the relevant
Circuit High - No corrective action(s) first.
sub type
information It is not possible to replicate the
failure event as certain entry
conditions must be satisfied
(for more information, refer to
section 303-13: Evaporative
Emissions / Description and
Operation). To verify the
customer concern, perform
routine Evaporative System
Diagnostic Check and re-read
DTCs.

Refer to the electrical circuit


diagrams and check the
diagnostic module tank leakage
pump circuit for short circuit to
power

P2404- Evaporative Diagnostic module tank leakage NOTES:


29 Emission System module internal failure
Leak Detection Changeover valve fault If purge valve related DTCs are
Pump Sense Circuit also set, perform the relevant
Range/Performance corrective action(s) first.
- Signal invalid
It is not possible to replicate the
failure event as certain entry
conditions must be satisfied
(for more information, refer to
section 303-13: Evaporative
Emissions / Description and
Operation). To verify the
customer concern, perform
routine Evaporative System
Diagnostic Check and re-read
DTCs.

Install a new diagnostic module


tank leakage module as
necessary

P2404- Evaporative Diagnostic module tank leakage NOTES:


2F Emission System module internal failure
Leak Detection Changeover valve fault If purge valve related DTCs are
Pump Sense Circuit also set, perform the relevant
Range/Performance corrective action(s) first.
- Signal erratic
It is not possible to replicate the
failure event as certain entry
conditions must be satisfied
(for more information, refer to
section 303-13: Evaporative
Emissions / Description and
Operation). To verify the
customer concern, perform
routine Evaporative System
Diagnostic Check and re-read
DTCs.

Install a new diagnostic module


tank leakage module as
necessary

P2405- Evaporative Diagnostic module tank leakage NOTES:


00 Emission System module internal failure
Leak Detection If purge valve related DTCs are
Pump Sense Circuit also set, perform the relevant
Low - No sub type corrective action(s) first.
information
It is not possible to replicate the
failure event as certain entry
conditions must be satisfied
(for more information, refer to
section 303-13: Evaporative
Emissions / Description and
Operation). To verify the
customer concern, perform
routine Evaporative System
Diagnostic Check and re-read
DTCs.

Install a new diagnostic module


tank leakage module as
necessary

P2406- Evaporative Diagnostic module tank leakage NOTES:


00 Emission System module internal failure
Leak Detection If purge valve related DTCs are
Pump Sense Circuit also set, perform the relevant
High - No sub type corrective action(s) first.
information
It is not possible to replicate the
failure event as certain entry
conditions must be satisfied
(for more information, refer to
section 303-13: Evaporative
Emissions / Description and
Operation). To verify the
customer concern, perform
routine Evaporative System
Diagnostic Check and re-read
DTCs.

Install a new diagnostic module


tank leakage module as
necessary

P240A- Evaporative Diagnostic module tank leakage heater NOTES:


00 Emission System circuit open circuit, high resistance
Leak Detection If purge valve related DTCs are
Pump Heater also set, perform the relevant
Circuit/Open - No corrective action(s) first.
sub type
information It is not possible to replicate the
failure event as certain entry
conditions must be satisfied
(for more information, refer to
section 303-13: Evaporative
Emissions / Description and
Operation). To verify the
customer concern, perform
routine Evaporative System
Diagnostic Check and re-read
DTCs.

Refer to the electrical circuit


diagrams and check the
diagnostic module tank leakage
heater circuit for open circuit,
high resistance

P240B- Evaporative Diagnostic module tank leakage heater NOTES:


00 Emission System circuit short circuit to ground
Leak Detection If purge valve related DTCs are
Pump Heater also set, perform the relevant
Circuit Low - No corrective action(s) first.
sub type
information It is not possible to replicate the
failure event as certain entry
conditions must be satisfied
(for more information, refer to
section 303-13: Evaporative
Emissions / Description and
Operation). To verify the
customer concern, perform
routine Evaporative System
Diagnostic Check and re-read
DTCs.

Refer to the electrical circuit


diagrams and check the
diagnostic module tank leakage
heater circuit for short circuit to
ground

P240C- Evaporative Diagnostic module tank leakage heater NOTES:


00 Emission System circuit short circuit to power
Leak Detection If purge valve related DTCs are
Pump Heater also set, perform the relevant
Circuit High - No corrective action(s) first.
sub type
information It is not possible to replicate the
failure event as certain entry
conditions must be satisfied
(for more information, refer to
section 303-13: Evaporative
Emissions / Description and
Operation). To verify the
customer concern, perform
routine Evaporative System
Diagnostic Check and re-read
DTCs.

Refer to the electrical circuit


diagrams and check the
diagnostic module tank leakage
heater circuit for short circuit to
power
P2450- Evaporative NOTES: Check and install a new
00 Emission Control diagnostic module tank leakage
System Switching - Circuit COV - as required. Refer to the
Valve warranty policy and procedures
Performance/Stuck LR - Circuit CHANGE OVER manual, or determine if any
Open - No sub type VALVE - prior approval programme is in
information operation, prior to the
Diagnostic module tank leakage failure installation of a new
module/component

P2451- Evaporative NOTES: Check and install a new


00 Emission Control diagnostic module tank leakage
System Switching - Circuit COV - as required. Refer to the
Valve warranty policy and procedures
Performance/Stuck LR - Circuit CHANGE OVER manual, or determine if any
Closed - No sub VALVE - prior approval programme is in
type information operation, prior to the
Diagnostic module tank leakage failure installation of a new
module/component

P250C- Engine Oil Level NOTE: Using the manufacturer


23 Sensor Circuit Low approved diagnostic system
- Signal stuck low - Circuit OIL_QUALITY_SENSOR - check datalogger signal, Sump
Oil Temperature - Measured
Oil temperature level sensor circuit (0x03F3)
short circuit to ground Refer to the electrical circuit
Oil temperature level sensor failure diagrams and check oil
temperature level sensor circuit
for short circuit to ground
Check and install a new oil
temperature level sensor as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

P250D- Engine Oil Level NOTE: Using the manufacturer


24 Sensor Circuit High approved diagnostic system
- Signal stuck high - Circuit OIL_QUALITY_SENSOR - check datalogger signal, Sump
Oil Temperature - Measured
Oil temperature level sensor circuit (0x03F3)
short circuit to power Refer to the electrical circuit
Oil temperature level sensor failure diagrams and check oil
temperature level sensor circuit
for short circuit to power
Check and install a new oil
temperature level sensor as
required. Refer to the warranty
policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component
P2544- Torque Inappropriate request from anti-lock Check for related DTCs within
64 Management braking system anti-lock braking system
Request Input module and refer to the relevant
Signal A - Signal DTC index
plausibility failure Using the manufacturer
approved diagnostic system,
complete a CAN network
integrity test

P2544- Torque Inappropriate request from anti-lock Check for related DTCs within
92 Management braking system anti-lock braking system
Request Input module and refer to the relevant
Signal A - DTC index
Performance or Using the manufacturer
incorrect operation approved diagnostic system,
complete a CAN network
integrity test

P2610- ECM/PCM Internal Instrument cluster fault Check for DTCs related to any
00 Engine Off Timer Central junction box fault of the components listed and
Performance - No CAN network error refer to relevant DTC index
sub type Using the manufacturer
information approved diagnostic system,
complete a CAN network
integrity test

P2610- ECM/PCM Engine Instrument cluster fault Check for DTCs related to any
84 Off Timer Central junction box fault of the components listed and
Performance - Engine coolant temperature sensor refer to relevant DTC index
Signal below fault Refer to the electrical circuit
allowable range Ambient temperature sensor fault diagrams and check engine
Low battery voltage coolant temperature sensor
CAN network error circuit for short circuit to
ground, short circuit to power,
open circuit
Refer to the electrical circuit
diagrams and check ambient air
temperature sensor circuit for
short circuit to ground, short
circuit to power, open circuit
Check the battery voltage,
repair as required
Using the manufacturer
approved diagnostic system,
complete a CAN network
integrity test

P2610- ECM/PCM Engine Instrument cluster fault Check for DTCs related to any
85 Off Timer Central junction box fault of the components listed and
Performance - Engine coolant temperature sensor refer to relevant DTC index
Signal above fault Refer to the electrical circuit
allowable range Ambient temperature sensor fault diagrams and check engine
Low battery voltage coolant temperature sensor
CAN network error circuit for short circuit to
ground, short circuit to power,
open circuit
Refer to the electrical circuit
diagrams and check ambient air
temperature sensor circuit for
short circuit to ground, short
circuit to power, open circuit
Check the battery voltage,
repair as required
Using the manufacturer
approved diagnostic system,
complete a CAN network
integrity test

P2610- ECM/PCM Internal Instrument cluster fault Check for DTCs related to any
87 Engine Off Timer Central junction box fault of the components listed, and
Performance - Engine coolant temperature sensor refer to relevant DTC index
Missing message fault Refer to the electrical circuit
Ambient temperature sensor fault diagrams and check engine
CAN network error coolant temperature sensor
circuit for short circuit to
ground, short circuit to power,
open circuit
Refer to the electrical circuit
diagrams and check ambient air
temperature sensor circuit for
short circuit to ground, short
circuit to power, open circuit
Using the manufacturer
approved diagnostic system,
complete a CAN network
integrity test

U0001- High Speed CAN NOTE: Refer to the electrical circuit


88 Communication diagrams and check CAN
Bus - Bus off - Circuit HS_CAN_NEG - HS_CAN_POS - network for short circuit to
ground, short circuit to power,
High speed CAN bus circuit, short open circuit
circuit to ground Using the manufacturer
High speed CAN bus circuit, short approved diagnostic system,
circuit to power carry out network integrity test
High speed CAN bus, open circuit

U0101- Lost CAN link engine control Using the manufacturer


00 Communication module/transmission control module approved diagnostic system,
with TCM - No sub network malfunction check transmission control
type information Transmission control module failure module for DTCs and refer to
the relevant DTC index
Using the manufacturer
approved diagnostic system,
complete a CAN network
integrity test
Refer to the electrical circuit
diagrams and check
transmission control module
power and ground circuit for
open circuit
Check CAN harness to
transmission control module,
repair as necessary

U0103- Lost CAN link engine control module/gear Refer to the electrical wiring
00 Communication shift module network malfunction diagrams and check power and
with Gear Shift ground connections to the gear
Control Module A - shift module
No sub type Using the manufacturer
information approved diagnostic system,
complete a CAN network
integrity test

U0104- Lost Vehicle configured for speed control, Check vehicle has correct speed
00 Communication but speed control module is not control module installed
With Cruise installed Using the manufacturer
Control Module - CAN Link engine control approved diagnostic system,
No sub type module/speed control module network check speed control module,
information malfunction anti-lock braking system
Speed control module power or ground module for DTCs and refer to
circuit, open circuit the relevant DTC index
Using the manufacturer
approved diagnostic system,
complete a CAN network
integrity test
Refer to the electrical circuit
diagrams and check speed
control module power and
ground circuit for open circuit
Check CAN harness to speed
control module, repair as
necessary

U0121- Lost CAN Link engine control module/anti- Using the manufacturer
00 Communication lock braking system module network approved diagnostic system,
With Anti-lock malfunction check anti-lock braking system
Braking System Anti-lock braking system module module for DTCs and refer to
(ABS) Control power or ground circuit, open circuit the relevant DTC index
Module - No sub Using the manufacturer
type information approved diagnostic system,
complete a CAN network
integrity test
Refer to the electrical circuit
diagrams and check anti-lock
braking system module power
and ground circuit for open
circuit
Check CAN harness to anti-
lock braking system module,
repair as necessary

U0128- Lost CAN Link engine control Refer to the electrical circuit
00 Communication module/electronic parking brake signal diagrams and check power and
With Park Brake missing network malfunction ground supplies to electronic
Control Module - parking brake
No sub type Using the manufacturer
information approved diagnostic system,
complete a CAN network
integrity test

U0132- Lost CAN link/suspension control module Refer to the electrical circuit
00 Communication network malfunction diagrams and check power and
with Suspension ground supplies to suspension
Control Module A - control module
No sub type Using the manufacturer
information approved diagnostic system,
complete a CAN network
integrity test

U0151- Lost Lost communication with restraints Refer to the electrical circuit
00 Communication control module over CAN or diagrams and check power and
with Restraints hardwired link ground supplies to restraints
Control Module - control module
No sub type Using the manufacturer
information approved diagnostic system,
complete a CAN network
integrity test

U0151- Lost Lost communication due to restraints Check restraints control module
87 Communication control module fault for associated DTCs and refer
with Restraints to relevant DTC index
Control Module - Refer to the electrical circuit
Missing message diagrams and check power and
ground supplies to restraints
control module
Using the manufacturer
approved diagnostic system,
complete a CAN network
integrity test

U0155- Lost CAN link between engine control Refer to the electrical circuit
00 Communication module and instrument cluster fault diagrams and check power and
with Instrument ground supplies to instrument
Panel Cluster (IPC) cluster
- No sub type Using the manufacturer
information approved diagnostic system,
complete a CAN network
integrity test

U0167- Lost Security challenge response timeout Refer to the electrical circuit
00 Communication Battery fault diagrams and check power and
with Vehicle ground supplies to the electric
Immobilizer steering column lock
Control Module - Check for related CAN DTCs
No sub type and refer to the relevant DTC
information index
Ensure the battery is in a fully
charged and serviceable
condition. Refer to the battery
care manual and the relevant
sections of the workshop
manual
Using the manufacturer
approved diagnostic system,
complete a CAN network
integrity test

U0300- Internal Control Engine control module has incorrect Check and install the correct
00 Module Software software installed engine control module software
Incompatibility - The engine control module is in Check and install the correct
No sub type expulsion mode. An incorrect engine control module as
information specification engine control module required. Refer to the warranty
has been installed to the vehicle policy and procedures manual,
or determine if any prior
approval programme is in
operation, prior to the
installation of a new
module/component

U0402- Invalid Data Transmission engine control module Using the manufacturer
00 Received From request corruption approved diagnostic system,
Transmission check transmission control
Control Module - module, for DTCs and refer to
No sub type the relevant DTC index
information Using the manufacturer
approved diagnostic system,
complete a CAN network
integrity test
Refer to the electrical circuit
diagrams and check high speed
CAN bus circuit for short
circuit, open circuit

U0402- Invalid Data Transmission engine control module Using the manufacturer
08 Received from request corruption approved diagnostic system,
TCM - Bus signal / High speed CAN bus circuit failure, check transmission control
message failures short, open circuit module, for DTCs and refer to
the relevant DTC index
Using the manufacturer
approved diagnostic system,
complete a CAN network
integrity test
Refer to the electrical circuit
diagrams and check high speed
CAN bus circuit for short
circuit, open circuit

U0402- Invalid Data Transmission to engine control module Using the manufacturer
64 Received from request corruption approved diagnostic system,
TCM - Signal High speed CAN bus signal corruption check transmission control
plausibility failure module, for DTCs and refer to
the relevant DTC index
Using the manufacturer
approved diagnostic system,
complete a CAN network
integrity test
Refer to the electrical circuit
diagrams and check high speed
CAN bus circuit for short
circuit, open circuit

U0402- Invalid Data Transmission control module shaft- Using the manufacturer
82 Received from speed faults approved diagnostic system,
TCM - Alive / check transmission control
sequence counter module, for DTCs and refer to
incorrect / not the relevant DTC index
updated
U0402- Invalid Data Transmission control module shaft- Using the manufacturer
83 Received from speed faults approved diagnostic system,
TCM - Value of check transmission control
signal protection module, for DTCs and refer to
calculation the relevant DTC index
incorrect
U0415- Invalid Data Electronic throttle unit, throttle Using the manufacturer
00 Received From position sensor 1 failure approved diagnostic system,
Anti-lock Braking Electronic throttle unit, throttle check for electronic throttle
System (ABS) position sensor 2 failure unit DTCs repair as necessary
Control Module - Electronic throttle unit harness short, Refer to the electrical circuit
No sub type open circuit diagrams and check electronic
information unit harness for short circuit,
open circuit
Refer to the warranty policy
and procedures manual, or
determine if any prior approval
programme is in operation,
prior to the installation of a new
module/component

U0415- Invalid Data Invalid request from anti-lock braking Using the manufacturer
64 Received From system approved diagnostic system,
Anti-lock Braking Torque up request higher than check anti-lock braking system,
System (ABS) expected from anti-lock braking for DTCs and refer to the
Control Module - system relevant DTC index
Signal plausibility Refer to the electrical circuit
failure diagrams and check high speed
CAN bus circuit for short
circuit, open circuit

U0415- Invalid Data Torque up request higher than Using the manufacturer
67 Received From expected from anti-lock braking approved diagnostic system,
Anti-lock Braking system check anti-lock braking system,
System (ABS) for DTCs and refer to the
Control Module - relevant DTC index
Signal incorrect Refer to the electrical circuit
after event diagrams and check high speed
CAN bus circuit for short
circuit, open circuit

U0426- Invalid Data Security code mis-match Check CAN network between
00 Received From This DTC will be logged if the engine control module,
Vehicle encrypted data exchange does not instrument cluster and central
Immobilizer match between engine control module junction box
Control Module - and the instrument cluster or central Refer to the electrical circuit
No sub type junction box diagrams and check power and
information ground circuit to engine control
module and instrument cluster
Check correct engine control
module and instrument cluster
installed
Re-synchronise ID by re-
configuring the engine control
module and instrument cluster
as new modules

U0447- Invalid Data The LIN to high speed CAN gateway This DTC has been inhibited in
81 Received From has informed the engine control the engine control module, as
Gateway "A" - module of a failure the LIN bus flag is set during
Invalid serial data normal operation
received
Published: 07-Dec-2017

2012.0 XF (X250), 100-00

General Information

Diagnostic Trouble Code Index - DTC: Engine


Control Module - 5.0L SC V8 - AJ133 (PCM) (G2133666)
DESCRIPTION AND OPERATION
Engine Control Module (PCM) 5.0L SC V8 - AJ133
WARNING:

Fuel injector voltage will reach 65 Volts during operation and have a high current requirement.

CAUTION:

Diagnosis by substitution from a donor vehicle is NOT acceptable. Substitution of control modules does not
guarantee confirmation of a fault, and may also cause additional faults in the vehicle being tested and/or the donor
vehicle

NOTES:

If the control module or a component is suspect and the vehicle remains under manufacturer warranty, refer to
the Warranty Policy and Procedures manual, or determine if any prior approval programme is in operation,
prior to the installation of a new module/component.

Generic scan tools may not read the codes listed, or may read only five digit codes. Match the five digits from
the scan tool to the first five digits of the seven digit code listed to identify the fault (the last two digits give
additional information read by the manufacturer-approved diagnostic system).

When performing electrical voltage or resistance tests, always use a digital multimeter (DMM) accurate to
three decimal places, and with an up-to-date calibration certificate. When testing resistance, always take the
resistance of the DMM leads into account.

Check and rectify basic faults before beginning diagnostic routines involving pinpoint tests.

If DTCs are recorded and, after performing the pinpoint tests, a fault is not present, an intermittent concern
may be the cause. Always check for loose connections and corroded terminals.

Check DDW for open campaigns. Refer to the corresponding bulletins and SSMs which may be valid for the
specific customer complaint and carry out the recommendations as required.

The table below lists all diagnostic trouble codes (DTCs) that could be logged in the electronic engine control
module, for additional diagnosis and testing information refer to the relevant diagnosis and testing section. For
additional information, refer to: Electronic Engine Controls (303-14E Electronic Engine Controls - V8 S/C 5.0L
Petrol, Diagnosis and Testing).

DTC Description Possible Causes Action


B10A2- Crash Input - No signal NOTE: Refer to the electrical
31 circuit diagrams and
- Circuit SRS_SIGNAL - check restraints control
module pulse width
Loss of communication between modulated SRS signal
restraints control module and engine line circuit, hard wired
control module connection between
engine control module
and restraints control
module for short circuit
to ground, short circuit
to power, open circuit.
Repair circuit as
required, clear the DTC
and retest

B10AC- Cruise Control Switch - The engine control module has Clear the DTC and
81 Invalid serial data received received an invalid command from the press all the steering
steering wheel switch pack wheel switches, re-
check for DTCs. Refer
to the electrical circuit
diagrams and check the
speed control switch
circuit for open circuit,
short circuit to power,
short circuit to ground,
disconnected
Check and install a new
steering wheel module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

B10AC- Cruise Control Switch - Cruise buttons alive counter is not Refer to the electrical
82 Alive / sequence counter incrementing. Which suggests that the circuit diagrams and
incorrect / not updated LIN bus is faulty check the speed control
Steering wheel module is not switch circuit for open
connected circuit, short circuit to
Steering wheel module failure power, short circuit to
ground, disconnected
Refer to the electrical
circuit diagrams and
check the LIN bus
between steering wheel
module and the CAN
gateway
Check and install a new
steering wheel module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component
B10AC- Cruise Control Switch - Cruise buttons checksum incorrect, Check and install new
83 Value of signal protection incorrect cruise switches fitted to cruise switches as
calculation incorrect vehicle required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

B10AC- Cruise Control Switch - Speed control switch circuit, open Check for related DTCs
96 Component internal failure circuit, short circuit to power, short in other central junction
circuit to ground, disconnected boxes
Speed control switch failure Refer to the electrical
Steering wheel module failure circuit diagrams and
check the speed control
switch circuit for open
circuit, short circuit to
power, short circuit to
ground, disconnected
Check and install a new
speed control switch as
required. Check and
install a new steering
wheel module as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

B10FF- Ignition Control - Event Spark plug(s) fault Refer to repair manual
68 information Wiring harness fault and check spark plug(s)
Ignition coil(s) fault for condition and
security. Replace any
defective components
as required
Refer to electrical
wiring diagrams and
check ignition coil
circuit for intermittent
open circuit, short
circuit to power, short
circuit to ground
Check and install a new
coil(s) as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

B11DB- Battery Monitoring NOTE: Refer to electrical


01 Module - General electrical wiring diagrams and
failure - Circuit BATTERY - check charging system
for faults. Perform any
Charging system fault repairs required
Battery monitoring signal line circuit Refer to the electrical
fault wiring diagrams and
Vehicle battery fault check the battery
monitoring system
module circuit for open
circuit, short circuit to
ground, short circuit to
power
Refer to the workshop
manual and the battery
care manual, inspect the
vehicle battery and
ensure it is fully
charged and serviceable
before performing
further tests

B11DB- Battery Monitoring NOTE: Refer to the electrical


87 Module - Missing message wiring diagrams and
- Circuit BATTERY - check the battery
monitoring system
Battery signal line circuit fault module circuit for open
circuit, short circuit to
ground, short circuit to
power
Refer to the electrical
circuit diagrams and
check the LIN circuit
for short circuit to
ground, short circuit to
power, open circuit

B1206- Crash Occurred - Event NOTE: Refer to the electrical


68 information circuit diagrams and
- Circuit SRS_SIGNAL - check the engine control
module to restraints
Engine control module has detected the control module circuit
vehicle has crashed - event information for short circuit to
DTC only ground, short circuit to
power, open circuit.
Repair circuit as
required, clear the DTC
and retest

C0031- Left Front Wheel Speed Invalid data received from anti-lock Check anti-lock braking
00 Sensor - No sub type braking system module - left front system module for
information wheel speed signal fault related DTCs and refer
to relevant DTC index
C0034- Right Front Wheel Speed Invalid data received from anti-lock Check anti-lock braking
00 Sensor - No sub type braking system module - right front system module for
information wheel speed signal fault related DTCs and refer
to relevant DTC index

C0037- Left Rear Wheel Speed Invalid data received from anti-lock Check anti-lock braking
00 Sensor - No sub type braking system module - left rear system module for
information wheel speed signal fault related DTCs and refer
to relevant DTC index

C003A- Right Rear Wheel Speed Invalid data received from anti-lock Check anti-lock braking
00 Sensor - No sub type braking system module - right rear system module for
information wheel speed signal fault related DTCs and refer
to relevant DTC index

P0010- Intake (A) Camshaft NOTE: Refer to the electrical


13 Position Actuator (Bank 1) circuit diagrams and
- Circuit open - Circuit VFS_IN_A - check intake (A)
camshaft position
Intake (A) camshaft position actuator actuator (Bank 1) circuit
(Bank 1) open circuit for open circuit
Engine control module interface Refer to the electrical
harness open circuit circuit diagrams and
check engine control
module interface
harness for open circuit

P0011- Intake (A) Camshaft NOTE: Refer to the electrical


00 Position Timing - Over- circuit diagrams and
Advanced (Bank 1) - No - Circuit VFS_IN_A - check intake (A)
sub type information camshaft position
Intake (A) camshaft position actuator actuator (Bank 1) circuit
(Bank 1) open circuit for open circuit
Engine control module interface Refer to the electrical
harness open circuit circuit diagrams and
check engine control
module interface
harness for open circuit

P0013- Exhaust (B) Camshaft NOTE: Refer to the electrical


13 Position Actuator (Bank 1) circuit diagrams and
- Circuit open - Circuit VFS_EX_A - check exhaust (B)
camshaft position
Exhaust (B) camshaft position actuator actuator (Bank 1) circuit
(Bank 1) open circuit for open circuit
Engine control module interface Refer to the electrical
harness open circuit circuit diagrams and
check engine control
module interface
harness for open circuit

P0015- Exhaust (B) Camshaft NOTE: Check for related DTC


00 Position Timing - Over- P0365-00. Refer to the
Retarded (Bank 1) - No - Circuit VFS_EX_A - electrical circuit
sub type information diagrams and check
Exhaust (B) camshaft position actuator exhaust (B) camshaft
(Bank 1) open circuit, short circuit to position actuator (Bank
ground, short circuit to power 1) for open circuit, short
circuit to ground, short
circuit to power

P0016- Crankshaft Position - NOTE: Check engine timing.


00 Camshaft Position Check camshaft sensor
Correlation - Bank 1 - Circuit VFS_EX_A - timing plate is installed
Sensor A - No sub type correctly. Check timing
information The relative positions of the crankshaft chain is installed
position sensor and cam timing plate correctly
teeth are not correct
Engine timing incorrect
Timing chain installed incorrectly
Variable valve timing forced fully
advanced

P0017- Crankshaft Position - NOTE: Check for related DTC


00 Camshaft Position P0365-00. Check
Correlation - Bank 1 - Circuit VFS_EX_A - engine timing. Check
Sensor B - No sub type camshaft sensor timing
information The relative positions of the crankshaft plate is installed
position sensor and camshaft timing correctly. Check timing
plate teeth are not correct chain is installed
Engine timing incorrect correctly
Timing chain installed incorrectly Refer to the electrical
Variable valve timing forced fully circuit diagrams and
advanced check exhaust (B)
camshaft position
actuator (Bank 1) for
open circuit, short
circuit to ground, short
circuit to power

P0018- Crankshaft Position - NOTE: Check engine timing.


00 Camshaft Position Check camshaft sensor
Correlation - Bank 2 - Circuit VFS_IN_B - timing plate is installed
Sensor A - No sub type correctly. Check timing
information The relative positions of the crankshaft chain is installed
position sensor and camshaft timing correctly
plate teeth are not correct
Engine timing incorrect
Timing chain installed incorrectly
Variable valve timing forced fully
advanced

P0019- Crankshaft Position - NOTE: Check engine timing.


00 Camshaft Position Check camshaft sensor
Correlation - Bank 2 - Circuit VFS_EX_B - timing plate is installed
Sensor B - No sub type correctly. Check timing
information The relative positions of the crankshaft chain is installed
position sensor and camshaft timing correctly
plate teeth are not correct
Engine timing incorrect
Timing chain installed incorrectly
Variable valve timing forced fully
advanced
P0020- Intake (A) Camshaft NOTE: Refer to the electrical
13 Position Actuator (Bank 2) circuit diagrams and
- Circuit open - Circuit VFS_IN_B - check intake valve
solenoid 2 for open
Intake valve solenoid 2 open circuit circuit

P0023- Exhaust (B) Camshaft NOTE: Refer to the electrical


13 Position Actuator (Bank 2) circuit diagrams and
- Circuit open - Circuit VFS_EX_B - check exhaust (B)
camshaft position
Exhaust (B) Camshaft Position actuator (Bank 2) circuit
actuator (Bank 2) circuit, open circuit for open circuit

P0026- Intake Valve Control NOTE: Check operation of


72 Solenoid Circuit intake valve solenoid 1.
Range/Performance (Bank - Circuit VFS_IN_A - Check and install a new
1) - Actuator stuck open intake valve solenoid 1
Intake valve solenoid 1 angle less than as required. Refer to the
target warranty policy and
Intake valve solenoid 1 slow or not procedures manual, or
operating determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0026- Intake Valve Control NOTE: Check operation of


77 Solenoid Circuit intake valve solenoid 1.
Range/Performance (Bank - Circuit VFS_IN_A - Check and install a new
1) - Commanded position intake valve solenoid 1
not reachable Intake valve solenoid 1 angle greater as required. Refer to the
than target warranty policy and
Intake valve solenoid 1 not returning to procedures manual, or
target in time determine if any prior
Intake valve solenoid 1 stuck advanced approval programme is
in operation, prior to the
installation of a new
module/component

P0027- Exhaust Valve Control NOTE: Check operation of


72 Solenoid Circuit exhaust valve solenoid
Range/Performance (Bank - Circuit VFS_EX_A - 1. Check and install a
1) - Actuator stuck open new exhaust valve
Exhaust valve solenoid 1 angle less solenoid 1 as required.
than target Refer to the warranty
Exhaust valve solenoid 1 slow or not policy and procedures
operating manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0027- Exhaust Valve Control NOTE: Check operation of


77 Solenoid Circuit exhaust valve solenoid
Range/Performance (Bank - Circuit VFS_EX_A - 1. Check and install a
1) - Commanded position new exhaust valve
not reachable Exhaust valve solenoid 1 angle greater solenoid 1 as required.
than target Refer to the warranty
Exhaust valve solenoid 1 not returning policy and procedures
to target in time manual, or determine if
Exhaust valve solenoid 1 stuck any prior approval
advanced programme is in
operation, prior to the
installation of a new
module/component

P0028- Intake Valve Control NOTE: Check operation of


72 Solenoid Circuit intake valve solenoid 2.
Range/Performance (Bank - Circuit VFS_IN_B - Check and install a new
2) - Actuator stuck open intake valve solenoid 2
Intake valve solenoid 2 angle less than as required. Refer to the
target warranty policy and
Intake valve solenoid 2 slow or not procedures manual, or
operating determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0028- Intake Valve Control NOTE: Check operation of


77 Solenoid Circuit intake valve solenoid 2.
Range/Performance (Bank - Circuit VFS_IN_B - Check and install a new
2) - Commanded position intake valve solenoid 2
not reachable Intake valve solenoid 2 angle greater as required. Refer to the
than target warranty policy and
Intake valve solenoid 2 not returning to procedures manual, or
target in time determine if any prior
Intake valve solenoid 2 stuck advanced approval programme is
in operation, prior to the
installation of a new
module/component

P0029- Exhaust Valve Control NOTE: Check operation of


72 Solenoid Circuit exhaust valve solenoid
Range/Performance (Bank - Circuit VFS_EX_B - 2. Check and install a
2) - Actuator stuck open new exhaust valve
Exhaust valve solenoid 2 angle less solenoid 2 as required.
than target Refer to the warranty
Exhaust valve solenoid 2 slow or not policy and procedures
operating manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0029- Exhaust Valve Control NOTE: Check operation of


77 Solenoid Circuit exhaust valve solenoid
Range/Performance (Bank - Circuit VFS_EX_B - 2. Check and install a
2) - Commanded position new exhaust valve
Exhaust valve solenoid 2 angle greater
not reachable solenoid 2 as required.
than target Refer to the warranty
Exhaust valve solenoid 2 not returning policy and procedures
to target in time manual, or determine if
Exhaust valve solenoid 2 stuck any prior approval
advanced programme is in
operation, prior to the
installation of a new
module/component

P0031- HO2S Heater Control NOTES: Using the Jaguar Land


11 Circuit Low (Bank 1, Rover approved
Sensor 1) - Circuit short to - Circuit HTR_CTRL_A_UPSTREAM diagnostic equipment
ground - check datalogger signal,
Oxygen Sensor (O2S)
LR - Circuit UHEGO HEATER A - Heater Duty Cycle
Bank 1 Sensor 1
Pre catalyst oxygen sensor-odd heater (0x03A1)
control circuit (Bank 1, Sensor 1) Refer to the electrical
circuit short circuit to ground circuit diagrams and
check pre catalyst
oxygen sensor-odd
heater control circuit
(Bank 1, Sensor 1)
circuit for short circuit
to ground

P0031- HO2S Heater Control NOTES: Using the Jaguar Land


13 Circuit Low (Bank 1, Rover approved
Sensor 1) - Circuit open - Circuit HTR_CTRL_A_UPSTREAM diagnostic equipment
- check datalogger signal,
Oxygen Sensor (O2S)
LR - Circuit UHEGO HEATER A - Heater Duty Cycle
Bank 1 Sensor 1
Pre catalyst oxygen sensor-odd heater (0x03A1)
control circuit (Bank 1, Sensor 1) Refer to the electrical
circuit, open circuit circuit diagrams and
check pre catalyst
oxygen sensor-odd
heater control circuit
(Bank 1, Sensor 1)
circuit for open circuit

P0032- HO2S Heater Control NOTES: Using the Jaguar Land


12 Circuit High (Bank 1, Rover approved
Sensor 1) - Circuit short to - Circuit HTR_CTRL_A_UPSTREAM diagnostic equipment
battery - check datalogger signal,
Oxygen Sensor (O2S)
LR - Circuit UHEGO HEATER A - Heater Duty Cycle
Bank 1 Sensor 1
Pre catalyst oxygen sensor-odd heater (0x03A1)
control circuit (Bank 1, Sensor 1) Refer to the electrical
circuit short circuit to power circuit diagrams and
check pre catalyst
oxygen sensor-odd
heater control circuit
(Bank 1, Sensor 1)
circuit for short circuit
to power

P0036- HO2S Heater Control NOTE: Using the Jaguar Land


00 Circuit (Bank 1, Sensor 2) Rover approved
- No sub type information - Circuit HTR_HEGO_A - diagnostic equipment
check datalogger signal,
Catalyst oxygen sensor heater circuit Oxygen Sensor (O2S)
control fuse failure Heater Duty Cycle
Post catalyst oxygen sensor-odd heater Bank 1 Sensor 2
control circuit short circuit to ground, (0x03A2)
short circuit to power, open circuit Refer to the electrical
Catalyst oxygen sensor heater circuit circuit diagrams and
control relay circuit short circuit to check post catalyst
ground, short circuit to power, open oxygen sensor-odd
circuit sensor fuse for open
Catalyst oxygen sensor heater circuit circuit
control relay failure Refer to the electrical
Post catalyst oxygen sensor-odd failure circuit diagrams and
check post catalyst
oxygen sensor-odd
sensor circuit for short
circuit to ground, short
circuit to power, open
circuit
Refer to the electrical
circuit diagrams and
check catalyst oxygen
sensor heater circuit
control relay circuit for
short circuit to ground,
short circuit to power,
open circuit
Check and install a new
catalyst oxygen sensor
heater control relay, as
required. Check and
install a new post
catalyst oxygen sensor-
odd as required. Refer
to the warranty policy
and procedures manual,
or determine if any
prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0051- HO2S Heater Control NOTES: Using the Jaguar Land


11 Circuit Low (Bank 2, Rover approved
Sensor 1) - Circuit short to - Circuit HTR_CTRL_B_UPSTREAM diagnostic equipment
ground - check datalogger signal,
Oxygen Sensor (O2S)
LR - Circuit UHEGO HEATER B - Heater Duty Cycle
Bank 2 Sensor 1
Pre catalyst oxygen sensor-even heater (0x03A4)
control circuit (Bank 2, Sensor 1) Refer to the electrical
circuit short circuit to ground circuit diagrams and
check pre catalyst
oxygen sensor-even
heater control circuit
(Bank 2, Sensor 1)
circuit for short circuit
to ground

P0051- HO2S Heater Control NOTES: Using the Jaguar Land


13 Circuit Low (Bank 2, Rover approved
Sensor 1) - Circuit open - Circuit HTR_CTRL_B_UPSTREAM diagnostic equipment
- check datalogger signal,
Oxygen Sensor (O2S)
LR - Circuit UHEGO HEATER B - Heater Duty Cycle
Bank 2 Sensor 1
Pre catalyst oxygen sensor-even heater (0x03A4)
control circuit (Bank 2, Sensor 1) Refer to the electrical
circuit, open circuit circuit diagrams and
check pre catalyst
oxygen sensor-even
heater control circuit
(Bank 2, Sensor 1)
circuit for open circuit

P0052- HO2S Heater Control NOTES: Using the Jaguar Land


12 Circuit High (Bank 2, Rover approved
Sensor 1) - Circuit short to - Circuit HTR_CTRL_B_UPSTREAM diagnostic equipment
battery - check datalogger signal,
Oxygen Sensor (O2S)
LR - Circuit UHEGO HEATER B - Heater Duty Cycle
Bank 2 Sensor 1
Pre catalyst oxygen sensor-even heater (0x03A4)
control circuit (Bank 2, Sensor 1) Refer to the electrical
circuit short circuit to power circuit diagrams and
check pre catalyst
oxygen sensor-even
heater control circuit
(Bank 2, Sensor 1)
circuit for short circuit
to power

P0054- HO2S Heater Resistance NOTES: Using the Jaguar Land


00 (Bank 1, Sensor 2) - No Rover approved
sub type information - Circuit HTR_CTRL_A_UPSTREAM diagnostic equipment
- check datalogger signal,
Oxygen Sensor (O2S)
LR - Circuit UHEGO HEATER A - Heater Duty Cycle
Bank 1 Sensor 1
Catalyst oxygen sensor heater circuit (0x03A1)
control fuse failure Refer to the electrical
Post catalyst oxygen sensor-odd heater circuit diagrams and
control circuit short circuit to ground, check post catalyst
short circuit to power, open circuit, oxygen sensor-odd
high resistance sensor fuse for open
Catalyst oxygen sensor heater circuit circuit
control relay circuit short circuit to
Refer to the electrical
ground, short circuit to power, open circuit diagrams and
circuit check post catalyst
Catalyst oxygen sensor heater circuit oxygen sensor-odd
control relay failure sensor circuit for short
Post catalyst oxygen sensor-odd failure circuit to ground, short
circuit to power, open
circuit, high resistance
Refer to the electrical
circuit diagrams and
check catalyst oxygen
sensor heater circuit
control relay circuit for
short circuit to ground,
short circuit to power,
open circuit
Check and install a new
catalyst oxygen sensor
heater control relay, as
required. Check and
install a new post
catalyst oxygen sensor-
odd as required. Refer
to the warranty policy
and procedures manual,
or determine if any
prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0056- HO2S Heater Control NOTE: Using the Jaguar Land


00 Circuit (Bank 2, Sensor 2) Rover approved
- No sub type information - Circuit HTR_HEGO_B - diagnostic equipment
check datalogger signal,
Post catalyst oxygen sensor-even Oxygen Sensor (O2S)
heater control circuit short circuit to Heater Duty Cycle
ground, short circuit to power, open Bank 2 Sensor 2
circuit (0x03A5)
Catalyst oxygen sensor heater circuit Refer to the electrical
control relay circuit short circuit to circuit diagrams and
ground, short circuit to power, open check post catalyst
circuit oxygen sensor-even
Catalyst oxygen sensor heater circuit sensor circuit for short
control relay failure circuit to ground, short
Post catalyst oxygen sensor-even circuit to power, open
failure circuit
Refer to the electrical
circuit diagrams and
check catalyst oxygen
sensor heater circuit
control relay circuit for
short circuit to ground,
short circuit to power,
open circuit
Check and install a new
catalyst oxygen sensor
heater control relay, as
required. Check and
install a new post
catalyst oxygen sensor-
even, as required. Refer
to the warranty policy
and procedures manual,
or determine if any
prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0060- HO2S Heater Resistance NOTES: Using the Jaguar Land


00 (Bank 2, Sensor 2) - No Rover approved
sub type information - Circuit HTR_CTRL_B_UPSTREAM diagnostic equipment
- check datalogger signal,
Oxygen Sensor (O2S)
LR - Circuit UHEGO HEATER B - Heater Duty Cycle
Bank 2 Sensor 2
Catalyst oxygen sensor heater circuit (0x03A5)
control fuse failure Refer to the electrical
Post catalyst oxygen sensor-even circuit diagrams and
heater control circuit short circuit to check post catalyst
ground, short circuit to power, open oxygen sensor-even
circuit, high resistance sensor fuse for open
Catalyst oxygen sensor heater circuit circuit
control relay circuit short circuit to Refer to the electrical
ground, short circuit to power, open circuit diagrams and
circuit check post catalyst
Catalyst oxygen sensor heater circuit oxygen sensor-even
control relay failure sensor circuit for short
Post catalyst oxygen sensor-even circuit to ground, short
failure circuit to power, open
circuit, high resistance
Refer to the electrical
circuit diagrams and
check catalyst oxygen
sensor heater circuit
control relay circuit for
short circuit to ground,
short circuit to power,
open circuit
Check and install a new
catalyst oxygen sensor
heater control relay, as
required. Check and
install a new post
catalyst oxygen sensor-
even as required. Refer
to the warranty policy
and procedures manual,
or determine if any
prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0069- MAP - Barometric Manifold absolute pressure sensor Using the Jaguar Land
29 Pressure Correlation - failure Rover approved
Signal invalid Engine control module failure diagnostic equipment
check datalogger signal,
Barometric Pressure
Sensor Voltage
(0x035A). Check for
related manifold
absolute pressure sensor
DTCs
Refer to the electrical
circuit diagrams and
check manifold absolute
pressure sensor circuit
for short circuit to
ground, short circuit to
power, open circuit
Check and install new
manifold absolute
pressure sensor as
required. Check and
install a new engine
control module as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0071- Ambient Air Temperature NOTES: Using the Jaguar Land


21 Sensor Range/Performance Rover approved
- Signal amplitude < Jaguar - Circuit diagnostic equipment
minimum AMBIENT_TEMP_SENSOR - check datalogger signal,
Ambient Air
LR - Circuit TAMB TEMP - Temperature Sensor
Voltage (0x03BA)
Ambient air temperature sensor circuit Refer to the electrical
short circuit to ground, short circuit to circuit diagrams and
power, open circuit check ambient air
Temperature and manifold absolute temperature sensor
pressure sensor circuit short circuit to circuit for short circuit
ground, short circuit to power, open to ground, short circuit
circuit to power, open circuit
Ambient air temperature sensor failure Refer to the electrical
Temperature and manifold absolute circuit diagrams and
pressure sensor failure check temperature and
manifold absolute
pressure sensor circuit
for short circuit to
ground, short circuit to
power, open circuit
Check and install a new
ambient air temperature
sensor as required.
Check and install a new
temperature and
manifold absolute
pressure sensor as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0071- Ambient Air Temperature NOTES: Using the Jaguar Land


22 Sensor Range/Performance Rover approved
- Signal amplitude > - Circuit AMBIENT_TEMP_SENSOR diagnostic equipment
maximum - check datalogger signal,
Ambient Air
LR - Circuit TAMB TEMP - Temperature Sensor
Voltage (0x03BA)
Ambient air temperature sensor circuit Refer to the electrical
short circuit to ground, short circuit to circuit diagrams and
power, open circuit check ambient air
Temperature and manifold absolute temperature sensor
pressure sensor circuit short circuit to circuit for short circuit
ground, short circuit to power, open to ground, short circuit
circuit to power, open circuit
Ambient air temperature sensor failure Refer to the electrical
Temperature and manifold absolute circuit diagrams and
pressure sensor failure check temperature and
manifold absolute
pressure sensor circuit
for short circuit to
ground, short circuit to
power, open circuit
Check and install a new
ambient air temperature
sensor as required.
Check and install a new
temperature and
manifold absolute
pressure sensor as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0072- Ambient Air Temperature NOTES: Using the Jaguar Land


00 Sensor Circuit Low - No Rover approved
sub type information - Circuit AMBIENT_TEMP_SENSOR diagnostic equipment
- check datalogger signal,
Ambient Air
LR - Circuit TAMB TEMP - Temperature Sensor
Voltage (0x03BA)
Ambient air temperature sensor circuit Refer to the electrical
short circuit to ground, open circuit, circuit diagrams and
high resistance check ambient air
Ambient air temperature sensor failure temperature sensor
circuit for short circuit
to ground, open circuit,
high resistance
Check and install a new
ambient air temperature
sensor as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0073- Ambient Air Temperature NOTES: Using the Jaguar Land


00 Sensor Circuit High - No Rover approved
sub type information - Circuit AMBIENT_TEMP_SENSOR diagnostic equipment
- check datalogger
signals Ambient Air
LR - Circuit TAMB TEMP - Temperature Sensor
Voltage (0x03BA)
Ambient air temperature sensor ground Refer to the electrical
circuit high resistance, open circuit circuit diagrams and
Ambient air temperature sensor signal check ambient air
circuit short circuit to power temperature sensor
Ambient air temperature sensor failure circuit for short circuit
to ground, high
resistance, short circuit
to power. Check
connector terminals for
corrosion or damage
Check and install a new
ambient air temperature
sensor as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P007B- Charge Air Cooler The engine control module measures a Leave vehicle turned off
23 Temperature Sensor signal that remains low when for a minimum of 8
Circuit Range/Performance transitions are expected hours and allow to soak
(Bank 1) - Signal stuck low Battery disconnection resulting in to a stable temperature.
errors in engine off time (short soaks Using the Jaguar Land
may look like long soaks) Rover approved
Electric block heater applied and not diagnostic equipment
detected check datalogger
Charge air temperature sensor circuit, signals - Ambient Air
short circuit to ground, short circuit to Temperature - (0xF446)
power, open circuit, high resistance - Engine Coolant
Connector is disconnected, connector Temperature (0xF405) -
pin is backed out, connector pin Boost Air Temperature
corrosion - Raw physical value
Charge air temperature sensor failure (0x0341) - Intake Air
Temperature (0xF40F) -
Engine Coolant
Temperature #2
(0x0489). All sensors
should be within 20
degºC of each other
Refer to electrical
circuit diagrams and
check the charge air
temperature sensor
circuit for short circuit
to ground, short circuit
to power, open circuit,
high resistance
Inspect connectors for
signs of water ingress,
and pins for damage
and/or corrosion
Check and install a new
charge air temperature
sensor as required
Using the Jaguar Land
Rover approved
diagnostic equipment
clear all stored DTCs
using the ‘Diagnosis
Menu’ tab and retest

P007B- Charge Air Cooler Battery disconnection resulting in Leave vehicle turned off
24 Temperature Sensor errors in engine off time (short soaks for a minimum of 8
Circuit Range/Performance may look like long soaks) hours and allow to soak
(Bank 1) - Signal stuck Electric block heater applied and not to a stable temperature.
high detected Using the Jaguar Land
Fuse failure Rover approved
Charge air temperature sensor circuit, diagnostic equipment
short circuit to ground, short circuit to check datalogger
power, open circuit, high resistance signals - Ambient Air
Connector is disconnected, connector Temperature - (0xF446)
pin is backed out, connector pin - Engine Coolant
corrosion Temperature (0xF405) -
Charge air temperature sensor failure Boost Air Temperature
Air charge coolant pump and control - Raw physical value
circuit, short circuit to ground, short (0x0341) - Intake Air
circuit to power, open circuit, high Temperature (0xF40F) -
resistance Engine Coolant
Air charge coolant pump relay failure Temperature #2
Air charge coolant pump failure (0x0489). All sensors
should be within 20
degºC of each other
Refer to electrical
circuit diagrams and
check for fuse failure,
install a new fuse as
required
Refer to electrical
circuit diagrams and
check the charge air
temperature sensor
circuit for short circuit
to ground, short circuit
to power, open circuit,
high resistance
Inspect connectors for
signs of water ingress,
and pins for damage
and/or corrosion
Check and install a new
charge air temperature
sensor as required
Refer to electrical
circuit diagrams and
check the air charge
coolant pump and
control circuit for short
circuit to ground, short
circuit to power, open
circuit, high resistance
Refer to electrical
circuit diagrams and
check the air charge
coolant pump for open
circuit, high resistance
Refer to the relevant
section of the workshop
manual and check the
air charge coolant pump
for correct operation.
Check and install a new
air charge coolant pump
as required
Using the Jaguar Land
Rover approved
diagnostic equipment
clear all stored DTCs
using the ‘Diagnosis
Menu’ tab and retest

P007B- Charge Air Cooler Battery disconnection resulting in Leave vehicle turned off
29 Temperature Sensor errors in engine off time (short soaks for a minimum of 8
Circuit Range/Performance may look like long soaks) hours and allow to soak
(Bank 1) - Signal invalid Electric block heater applied and not to a stable temperature.
detected Using the Jaguar Land
Fuse failure Rover approved
Charge air temperature sensor circuit, diagnostic equipment
short circuit to ground, short circuit to check datalogger
power, open circuit, high resistance signals - Ambient Air
Connector is disconnected, connector Temperature - (0xF446)
pin is backed out, connector pin - Engine Coolant
corrosion Temperature (0xF405) -
Charge air temperature sensor failure Boost Air Temperature
Air charge coolant pump and control - Raw physical value
circuit, short circuit to ground, short (0x0341) - Intake Air
circuit to power, open circuit, high Temperature (0xF40F) -
resistance Engine Coolant
Air charge coolant pump relay failure Temperature #2
Air charge coolant pump failure (0x0489). All sensors
should be within 20
degºC of each other
Refer to electrical
circuit diagrams and
check for fuse failure,
install a new fuse as
required
Refer to electrical
circuit diagrams and
check the charge air
temperature sensor
circuit for short circuit
to ground, short circuit
to power, open circuit,
high resistance
Inspect connectors for
signs of water ingress,
and pins for damage
and/or corrosion
Check and install a new
charge air temperature
sensor as required
Refer to electrical
circuit diagrams and
check the air charge
coolant pump and
control circuit for short
circuit to ground, short
circuit to power, open
circuit, high resistance
Refer to electrical
circuit diagrams and
check the air charge
coolant pump for open
circuit, high resistance
Refer to the relevant
section of the workshop
manual and check the
air charge coolant pump
for correct operation.
Check and install a new
air charge coolant pump
as required
Using the Jaguar Land
Rover approved
diagnostic equipment
clear all stored DTCs
using the ‘Diagnosis
Menu’ tab and retest

P007C- Charge Air Cooler Charge air temperature sensor circuit, Refer to electrical
00 Temperature Sensor short circuit to ground, short circuit to circuit diagrams and
Circuit Low (Bank 1) - No power, open circuit, high resistance check the charge air
sub type information Connector is disconnected, connector temperature sensor
pin is backed out, connector pin circuit for short circuit
corrosion to ground, short circuit
Charge air temperature sensor failure to power, open circuit,
high resistance
Inspect connectors for
signs of water ingress,
and pins for damage
and/or corrosion
Check and install a new
charge air temperature
sensor as required
Using the Jaguar Land
Rover approved
diagnostic equipment
clear all stored DTCs
using the ‘Diagnosis
Menu’ tab and retest

P007D- Charge Air Cooler Charge air temperature sensor circuit, Refer to electrical
00 Temperature Sensor short circuit to ground, short circuit to circuit diagrams and
Circuit High (Bank 1) - No power, open circuit, high resistance check the charge air
sub type information Connector is disconnected, connector temperature sensor
pin is backed out, connector pin circuit for short circuit
corrosion to ground, short circuit
Charge air temperature sensor failure to power, open circuit,
high resistance
Inspect connectors for
signs of water ingress,
and pins for damage
and/or corrosion
Check and install a new
charge air temperature
sensor as required
Using the Jaguar Land
Rover approved
diagnostic equipment
clear all stored DTCs
using the ‘Diagnosis
Menu’ tab and retest

P0087- Fuel Rail/System Pressure NOTE: Using the Jaguar Land


00 - Too Low - No sub type Rover approved
information - Circuit FUEL_HIGH_PRESS_SENSOR - diagnostic equipment
check datalogger signal,
Fuel rail pressure sensor circuit short Fuel Rail Pressure
circuit to ground, open circuit, high Sensor - High Range
resistance Sensor Voltage
Fuel rail pressure sensor failure (0x0377)
Fuel lines leaking or restricted Refer to the electrical
Fuel pump failure circuit diagrams and
check fuel rail pressure
sensor circuit for short
circuit to ground, open
circuit, high resistance
Check for fuel pump
related DTCs. Check
fuel lines for leakage or
restriction
Check and install new
fuel rail pressure sensor
as required. Check and
install a new fuel pump
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0088- Fuel Rail/System Pressure NOTE: Using the Jaguar Land


00 - Too High - No sub type Rover approved
information - Circuit FUEL_HIGH_PRESS_SENSOR - diagnostic equipment
check datalogger signal,
Fuel rail pressure sensor circuit short Fuel Rail Pressure
to each other, high resistance, short Sensor - High Range
circuit to power Sensor Voltage
Fuel rail pressure sensor failure (0x0377)
Refer to the electrical
circuit diagrams and
check fuel rail pressure
sensor circuit for short
to each other, high
resistance, short circuit
to power
Check and install new
fuel rail pressure sensor
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P008A- Low Pressure Fuel System NOTE: Using the Jaguar Land
00 Pressure - Too Low - No Rover approved
sub type information - Circuit diagnostic equipment
LOW_PRESS_FUEL_PRESS_SENSOR - check datalogger signal,
Fuel Rail Pressure -
Low pressure fuel sensor circuit Low Range Sensor
failure, short circuit to ground, short Voltage (0x0376)
circuit to power, open circuit Check fuel system for
Fuel pump driver module circuit short leakage
circuit to ground, short circuit to Refer to the electrical
power, open circuit circuit diagrams and
Low pressure fuel check low pressure fuel
Fuel pump driver module failure sensor circuit for short
circuit to ground, short
circuit to power, open
circuit
Refer to the electrical
circuit diagrams and
check fuel pump driver
module circuit short
circuit to ground, short
circuit to power, open
circuit
Check and install a new
low pressure fuel sensor
as required. Check and
install a new fuel pump
driver module as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P008B- Low Pressure Fuel System NOTE: Using the Jaguar Land
00 Pressure - Too High - No Rover approved
sub type information - Circuit diagnostic equipment
LOW_PRESS_FUEL_PRESS_SENSOR - check datalogger signal,
Fuel Rail Pressure -
Low pressure fuel sensor circuit short Low Range Sensor
circuit to ground, short circuit to Voltage (0x0376)
power, open circuit Refer to the electrical
Fuel pump driver module circuit short circuit diagrams and
circuit to ground, short circuit to check low pressure fuel
power, open circuit sensor circuit for short
Blockage or restriction in low pressure circuit to ground, short
fuel line circuit to power, open
Low pressure fuel sensor failure circuit. Check for
Fuel pump driver module failure blockage or restriction
in low pressure fuel line
Refer to the electrical
circuit diagrams and
check fuel pump driver
module circuit short
circuit to ground, short
circuit to power, open
circuit
Check and install a new
low pressure fuel sensor
as required. Check and
install a new fuel pump
driver module as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P00AB- Intake Air Temperature NOTE: Using the Jaguar Land


23 Sensor 1 Circuit Rover approved
Range/Performance (Bank - Circuit INLET_AIR_TEMP_SENSOR_B - diagnostic equipment
2) - Signal stuck low check datalogger signal,
Intake air temperature sensor bank 2 Intake Air Temperature
circuit short circuit to ground, open Sensor Bank 2 (0x0312)
circuit Refer to the electrical
Intake air temperature sensor bank 2 circuit diagrams and
failure check intake air
temperature sensor bank
2 circuit for short circuit
to ground, open circuit
Check and install a new
intake air temperature
sensor bank 2 as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P00AB- Intake Air Temperature NOTE: Using the Jaguar Land


24 Sensor 1 Circuit Rover approved
Range/Performance (Bank - Circuit INLET_AIR_TEMP_SENSOR_B - diagnostic equipment
2) - Signal stuck high check datalogger signal,
Intake air temperature sensor bank 2 Intake Air Temperature
circuit short circuit to power Sensor Bank 2 (0x0312)
Intake air temperature sensor bank 2 Refer to the electrical
failure circuit diagrams and
check intake air
temperature sensor bank
2 circuit for short circuit
to power
Check and install a new
intake air temperature
sensor bank 2 as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component
P00AB- Intake Air Temperature NOTE: Using the Jaguar Land
29 Sensor 1 Circuit Rover approved
Range/Performance (Bank - Circuit INLET_AIR_TEMP_SENSOR_B - diagnostic equipment
2) - Signal invalid check datalogger signal,
Intake air temperature sensor bank 2 Intake Air Temperature
circuit short circuit to ground, open Sensor Bank 2 (0x0312)
circuit, short circuit to power Refer to the electrical
Intake air temperature sensor bank 2 circuit diagrams and
failure check intake air
temperature sensor bank
2 circuit for open
circuit, short circuit to
ground, short circuit to
power
Check and install a new
intake air temperature
sensor bank 2 as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P00AC- Intake Air Temperature NOTE: Using the Jaguar Land


00 Sensor 1 Circuit Low Rover approved
(Bank 2) - No sub type - Circuit INLET_AIR_TEMP_SENSOR_B - diagnostic equipment
information check datalogger signal,
Intake air temperature sensor bank 2 Intake Air Temperature
sensing circuit short circuit to ground, Sensor Bank 2 (0x0312)
high resistance, disconnected Refer to the electrical
Intake air temperature sensor bank 2 circuit diagrams and
failure check intake air
temperature sensor bank
2 circuit for short circuit
to ground, open circuit,
high resistance,
disconnected connector
Check and install a new
intake air temperature
sensor bank 2 as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P00AD- Intake Air Temperature NOTE: Using the Jaguar Land


00 Sensor 1 Circuit High Rover approved
(Bank 2) - No sub type - Circuit INLET_AIR_TEMP_SENSOR_B - diagnostic equipment
information check datalogger signal,
Intake air temperature sensor bank 2 Intake Air Temperature
sensing circuit short ground, short Sensor Bank 2 (0x0312)
circuit to power, open circuit, high Refer to the electrical
resistance circuit diagrams and
Intake air temperature sensor bank 2 check intake air
failure temperature sensor bank
2 circuit for short
ground, short circuit to
power, open circuit,
high resistance. Check
for backed out or
damaged connector pins
Check and install a new
intake air temperature
sensor bank 2 as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P00C6- Fuel Rail Pressure Too No fuel at pump Check fuel supply to
00 Low - Engine Cranking - Injector stuck open both pumps (if engine
No sub type information Fuel pressure sensor signal stuck runs then supply is not
Fuel pump failure suspect). If engine does
not run perform fuel
prime routine. Use fuel
pump diagnostic routine
to determine if one
pump has failed, if so
replace pump. If a fuel
injector is stuck open
the exhaust will smell
of fuel and fuelling
adaptions may indicate
rich shift. Perform
checks for as DTC
P0191-00
Check and install a new
fuel pump as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0101- Mass or Volume Air Flow Intake air distribution and filtering Using the manufacturer
00 A Circuit components incorrectly installed approved smoke tester
Range/Performance - No Leakage from intake air system check intake air
sub type information Blocked air cleaner element(s) distribution and filtering
Blocked engine breather components for leakage
Blockage in intake air system and correct installation
Mass air flow sensor seal failure Check air cleaner
Connector is disconnected, connector element is free from
terminal is backed out, connector restriction and in
terminal corrosion serviceable condition
Mass air flow sensor circuit, short Ensure the engine
circuit to ground, short circuit to breather system is
power, open circuit, high resistance correctly installed and
Carbon build-up on throttle blade in serviceable condition
Blocked injectors Check for mass air flow
Blocked catalysts sensor seal integrity and
Mass air flow sensor failure correct installation
Inspect connectors for
signs of water ingress,
and pins for damage
and/or corrosion
Refer to the electrical
circuit diagrams and
check mass air flow
sensor circuit for short
circuit to ground, short
circuit to power, open
circuit, high resistance
Make sure throttle blade
is clean of carbon
Check for blocked
injectors
Check for blocked
catalysts
Clear the DTC and
retest
Refer to the relevant
section of workshop
manual. Reset fuelling
adaptions and carry out
Powertrain Control
Module (PCM) Long
Drive Cycle Self-Test
Check and install new
mass air flow sensor as
required

P0102- Mass or Volume Air Flow Fuse failure Check for fuse failure
00 A Circuit Low - No sub Connector is disconnected, connector Inspect connectors for
type information terminal is backed out, connector signs of water ingress,
terminal corrosion and pins for damage
Mass air flow sensor circuit, short and/or corrosion
circuit to ground, short circuit to Refer to the electrical
power, open circuit, high resistance circuit diagrams and
Mass air flow sensor failure check mass air flow
sensor circuit for short
circuit to ground, short
circuit to power, open
circuit, high resistance
Clear the DTC and
retest
Refer to the relevant
section of workshop
manual. Reset fuelling
adaptions and carry out
Powertrain Control
Module (PCM) Long
Drive Cycle Self-Test
Check and install new
mass air flow sensor as
required

P0103- Mass or Volume Air Flow Connector is disconnected, connector Using the Jaguar Land
00 A Circuit High - No sub terminal is backed out, connector Rover approved
type information terminal corrosion diagnostic equipment
Mass air flow sensor circuit, short check datalogger signal,
circuit to ground, short circuit to Mass Air Flow Sensor,
power, open circuit, high resistance Bank 1 (0x0314)
Blocked air cleaner element(s) Inspect connectors for
Blockage in air intake system signs of water ingress,
Mass air flow sensor failure and pins for damage
and/or corrosion
Refer to the electrical
circuit diagrams and
check mass air flow
sensor circuit for short
circuit to ground, short
circuit to power, open
circuit, high resistance
Check air cleaner
element is free from
restriction and in
serviceable condition
Check air intake system
for blockage
Clear the DTC and
retest
Refer to the relevant
section of workshop
manual. Reset fuelling
adaptions and carry out
Powertrain Control
Module (PCM) Long
Drive Cycle Self-Test
Check and install new
mass air flow sensor as
required

P0106- Manifold Absolute NOTE: Check air cleaner


00 Pressure/BARO Sensor element is free from
Range/Performance - No - Circuit MAP_SENSOR - restriction
sub type information Check for leak from air
Blocked air cleaner element(s) intake system, rectify as
Intake manifold air leak required
Manifold absolute pressure sensor Refer to the electrical
circuit short circuit to ground, short circuit diagrams and
circuit to power, open circuit, high check manifold absolute
resistance pressure sensor circuit
Engine breather leak for short circuit to
Carbon build up on throttle plate ground, short circuit to
Exhaust system blocked power, open circuit,
Manifold absolute pressure sensor high resistance
failure Ensure the engine
BARO sensor failure breather system is
correctly installed and
in serviceable condition
Make sure throttle blade
is clean of carbon
Check for blocked
exhaust
Check and install a new
manifold absolute
pressure sensor as
required. Check for
related BARO sensor
DTC P0069-29. Refer
to the warranty policy
and procedures manual,
or determine if any
prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0107- Manifold Absolute NOTE: Refer to the electrical


00 Pressure/BARO Sensor circuit diagrams and
Low - No sub type - Circuit MAP_SENSOR - check manifold absolute
information pressure sensor circuit
Manifold absolute pressure sensor for short circuit to
circuit short circuit to ground, open ground, open circuit,
circuit, high resistance high resistance
Manifold absolute pressure sensor Check and install a new
failure manifold absolute
pressure sensor as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0108- Manifold Absolute NOTE: Refer to the electrical


00 Pressure/BARO Sensor circuit diagrams and
High - No sub type - Circuit MAP_SENSOR - check manifold absolute
information pressure sensor circuit
Manifold absolute pressure sensor for short circuit to
circuit short circuit to power, open power, open circuit,
circuit, high resistance high resistance
Manifold absolute pressure sensor Check and install a new
failure manifold absolute
pressure sensor as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P010B- Mass or Volume Air Flow Intake air distribution and filtering Using the manufacturer
00 B Circuit components incorrectly installed approved smoke tester
Range/Performance - No Leakage from intake air system check intake air
sub type information Blocked air cleaner element(s) distribution and filtering
Blocked engine breather components for leakage
Blockage in intake air system and correct installation
Mass air flow sensor seal failure Check air cleaner
Connector is disconnected, connector element is free from
terminal is backed out, connector restriction and in
terminal corrosion serviceable condition
Mass air flow sensor circuit, short Ensure the engine
circuit to ground, short circuit to breather system is
power, open circuit, high resistance correctly installed and
Carbon build-up on throttle blade in serviceable condition
Blocked injectors Check for mass air flow
Blocked catalysts sensor seal integrity and
Mass air flow sensor failure correct installation
Inspect connectors for
signs of water ingress,
and pins for damage
and/or corrosion
Refer to the electrical
circuit diagrams and
check mass air flow
sensor circuit for short
circuit to ground, short
circuit to power, open
circuit, high resistance
Make sure throttle blade
is clean of carbon
Check for blocked
injectors
Check for blocked
catalysts
Clear the DTC and
retest
Refer to the relevant
section of workshop
manual. Reset fuelling
adaptions and carry out
Powertrain Control
Module (PCM) Long
Drive Cycle Self-Test
Check and install new
mass air flow sensor as
required

P010C- Mass or Volume Air Flow Fuse failure Check for fuse failure
00 B Circuit Low - No sub Connector is disconnected, connector Inspect connectors for
type information terminal is backed out, connector signs of water ingress,
terminal corrosion and pins for damage
Mass air flow sensor circuit, short and/or corrosion
circuit to ground, short circuit to Refer to the electrical
power, open circuit, high resistance circuit diagrams and
Mass air flow sensor failure check mass air flow
sensor circuit for short
circuit to ground, short
circuit to power, open
circuit, high resistance
Clear the DTC and
retest
Refer to the relevant
section of workshop
manual. Reset fuelling
adaptions and carry out
Powertrain Control
Module (PCM) Long
Drive Cycle Self-Test
Check and install new
mass air flow sensor as
required

P010D- Mass or Volume Air Flow Connector is disconnected, connector Using the Jaguar Land
00 B Circuit High - No sub terminal is backed out, connector Rover approved
type information terminal corrosion diagnostic equipment
Mass air flow sensor circuit, short check datalogger signal,
circuit to ground, short circuit to Mass Air Flow Sensor 2
power, open circuit, high resistance Voltage (0x0503)
Blocked air cleaner element(s) Inspect connectors for
Blockage in air intake system signs of water ingress,
Mass air flow sensor failure and pins for damage
and/or corrosion
Refer to the electrical
circuit diagrams and
check mass air flow
sensor circuit for short
circuit to ground, short
circuit to power, open
circuit, high resistance
Check air cleaner
element is free from
restriction and in
serviceable condition
Check air intake system
for blockage
Clear the DTC and
retest
Refer to the relevant
section of workshop
manual. Reset fuelling
adaptions and carry out
Powertrain Control
Module (PCM) Long
Drive Cycle Self-Test
Check and install new
mass air flow sensor as
required
P010F- Mass or Volume Air Flow Intake air distribution and filtering Using the manufacturer
00 Sensor A/B Correlation - components incorrectly installed approved smoke tester
No sub type information Leakage from intake air system check intake air
Blocked air cleaner element(s) distribution and filtering
Blocked engine breather components for leakage
Blockage in intake air system and correct installation
Mass air flow sensor seal failure Check air cleaner
Connector is disconnected, connector element is free from
terminal is backed out, connector restriction and in
terminal corrosion serviceable condition
Mass air flow sensor circuit, short Ensure the engine
circuit to ground, short circuit to breather system is
power, open circuit, high resistance correctly installed and
Carbon build-up on throttle blade in serviceable condition
Blocked injectors Check for mass air flow
Blocked catalysts sensor seal integrity and
Mass air flow sensor failure correct installation
Inspect connectors for
signs of water ingress,
and pins for damage
and/or corrosion
Refer to the electrical
circuit diagrams and
check mass air flow
sensor circuit for short
circuit to ground, short
circuit to power, open
circuit, high resistance
Make sure throttle blade
is clean of carbon
Check for blocked
injectors
Check for blocked
catalysts
Clear the DTC and
retest
Refer to the relevant
section of workshop
manual. Reset fuelling
adaptions and carry out
Powertrain Control
Module (PCM) Long
Drive Cycle Self-Test
Check and install new
mass air flow sensor as
required

P0111- Intake Air Temperature NOTE: Refer to the electrical


23 Sensor 1 Circuit circuit diagrams and
Range/Performance - - Circuit INLET_AIR_TEMP_SENSOR_A - check intake air
Signal stuck low temperature sensor
Intake air temperature sensor short circuit for short circuit
circuit to ground, open circuit, high to ground, open circuit,
resistance high resistance
Intake air temperature sensor failure Check and install a new
intake air temperature
sensor as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0111- Intake Air Temperature NOTE: Refer to the electrical


24 Sensor 1 Circuit circuit diagrams and
Range/Performance - - Circuit INLET_AIR_TEMP_SENSOR_A - check intake air
Signal stuck high temperature sensor
Intake air temperature sensor circuit circuit for short circuit
short circuit to power, open circuit to power, open circuit
Intake air temperature sensor failure Check and install a new
intake air temperature
sensor as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0111- Intake Air Temperature NOTE: Refer to the electrical


29 Sensor 1 Circuit circuit diagrams and
Range/Performance - - Circuit INLET_AIR_TEMP_SENSOR_A - check intake air
Signal invalid temperature sensor
Intake air temperature sensor circuit circuit for short circuit
short circuit to ground, short circuit to to ground, short circuit
power, open circuit to power, open circuit
Intake air temperature sensor failure Check and install a new
intake air temperature
sensor as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0112- Intake Air Temperature NOTE: Refer to the electrical


00 Sensor 1 Circuit Low circuit diagrams and
(Bank 1) - No sub type - Circuit INLET_AIR_TEMP_SENSOR_A - check intake air
information temperature sensor
Intake air temperature sensor circuit circuit for short circuit
short circuit to ground, short circuit to to ground, short circuit
power, open circuit, high resistance to power, open circuit,
Intake air temperature sensor failure high resistance
Check and install a new
intake air temperature
sensor bank 1 as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0113- Intake Air Temperature NOTE: Refer to the electrical


00 Sensor 1 Circuit High circuit diagrams and
(Bank 1) - No sub type - Circuit INLET_AIR_TEMP_SENSOR_A - check intake air
information temperature sensor
Intake air temperature sensor circuit circuit for short circuit
short circuit to power, open circuit, to power, open circuit,
high resistance high resistance
Intake air temperature sensor failure Check and install a new
intake air temperature
sensor bank 1 as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0116- Engine Coolant NOTE: Using the Jaguar Land


23 Temperature Sensor 1 Rover approved
Circuit Range/Performance - Circuit COOLANT_TEMP_SENSOR - diagnostic equipment
- Signal stuck low check datalogger signal,
Battery reset carried out when the Engine Coolant
engine was warm/hot Temperature Sensor
Engine coolant temperature sensor 1 Voltage (0x0357)
sensing circuit intermittent high Check for related DTC
resistance P2610- 87. Start the
Engine coolant temperature sensor 1 engine and switch off.
failure Clear DTC and re-test
Refer to the electrical
circuit diagrams and
check engine coolant
temperature sensor 1
circuit for intermittent
high resistance
Check and install a new
engine coolant
temperature sensor 1 as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component
P0116- Engine Coolant NOTE: Using the Jaguar Land
24 Temperature Sensor 1 Rover approved
Circuit Range/Performance - Circuit COOLANT_TEMP_SENSOR - diagnostic equipment
- Signal stuck high check datalogger signal,
Engine coolant temperature sensor 1 Engine Coolant
sensing circuit intermittent high Temperature Sensor
resistance Voltage (0x0357)
Engine coolant temperature sensor 1 Check for related DTC
failure P2610- 87. Start the
Battery reset carried out when the engine and switch off.
engine was warm/hot Clear DTC and re-test
Refer to the electrical
circuit diagrams and
check engine coolant
temperature sensor 1
circuit for intermittent
high resistance
Check and install a new
engine coolant
temperature sensor 1 as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0116- Engine Coolant NOTE: Fill cooling system to


29 Temperature Sensor 1 correct level and
Circuit Range/Performance - Circuit COOLANT_TEMP_SENSOR - specification
- Signal invalid Using the Jaguar Land
Low coolant level Rover approved
Engine coolant temperature sensor 1 diagnostic equipment
sensing circuit - intermittent high check datalogger signal,
resistance Engine Coolant
Engine coolant temperature sensor 1 Temperature Sensor
failure Voltage (0x0357)
Possible airlock in cooling system Refer to the electrical
circuit diagrams and
check engine coolant
temperature sensor 1
circuit for intermittent
high resistance
Check and install new
engine coolant
temperature sensor 1 as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component
Bleed cooling system

P0117- Engine Coolant NOTE: Using the Jaguar Land


16 Temperature Sensor 1 Rover approved
Circuit Low - Circuit - Circuit COOLANT_TEMP_SENSOR - diagnostic equipment
voltage below threshold check datalogger signal,
Engine coolant temperature sensor 1 Engine Coolant
circuit short circuit to ground Temperature Sensor
Engine coolant temperature sensor 1 Voltage (0x0357)
failure Refer to the electrical
circuit diagrams and
check engine coolant
temperature sensor 1
circuit for short circuit
to ground
Check and install a new
Engine coolant
temperature sensor 1 as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0118- Engine Coolant NOTE: Using the Jaguar Land


17 Temperature Sensor 1 Rover approved
Circuit High - Circuit - Circuit COOLANT_TEMP_SENSOR - diagnostic equipment
voltage above threshold check datalogger signal,
Engine coolant temperature sensor 1 Engine Coolant
circuit short circuit to power, open Temperature Sensor
circuit, sensor disconnected Voltage (0x0357)
Engine coolant temperature sensor 1 Refer to the electrical
failure circuit diagrams and
check engine coolant
temperature sensor 1
circuit for short circuit
to power, open circuit,
sensor disconnected
Check and install new
engine coolant
temperature sensor 1 as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0121- Throttle/Pedal Position Corrupt engine control module Using the Jaguar Land
00 Sensor A Circuit software flash Rover approved
Range/Performance - No Engine control module power supply diagnostic equipment
sub type information circuit open circuit, high resistance check and install latest
Engine control module damage relevant level of
through water ingress, internal fault software to the engine
control module
Refer to the electrical
circuit diagrams and
check engine control
module power supply
circuit for open circuit,
high resistance
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0122- Throttle/Pedal Position NOTE: Refer to the electrical


00 Sensor A Circuit Low - No circuit diagrams and
sub type information - Circuit check throttle position
THROTTLE_POSITION_SENSOR_1 - sensor 1 circuit for short
circuit to ground, open
Throttle position sensor 1 circuit short circuit
circuit to ground, open circuit Clear DTC and repeat
Throttle position sensor 1 failure automated diagnostic
procedure using the
Jaguar Land Rover
approved diagnostic
equipment. If DTC
remains suspect the
electronic throttle unit
Check and install a new
electronic throttle unit
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0123- Throttle/Pedal Position NOTE: Refer to the electrical


00 Sensor A Circuit High - No circuit diagrams and
sub type information - Circuit check throttle position
THROTTLE_POSITION_SENSOR_1 - sensor 1 circuit for short
circuit to ground, short
Throttle position sensor 1 circuit short circuit to power, open
circuit to ground, short circuit to circuit
power, open circuit Clear DTC and repeat
Throttle position sensor 1 failure automated diagnostic
procedure using the
Jaguar Land Rover
approved diagnostic
equipment. If DTC
remains suspect the
electronic throttle unit
Check and install a new
electronic throttle unit
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0125- Insufficient Coolant Temp Coolant temperature sensor 1 circuit, Refer to the electrical
00 For Closed Loop Fuel open circuit, high resistance circuit diagrams and
Control - No sub type Engine coolant temperature sensor 1 check engine coolant
information failure temperature sensor 1
circuit for open circuit,
high resistance
Check and install a new
engine coolant
temperature sensor 1.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0126- Insufficient Coolant Temp Thermostat stuck open Refer to the electrical
26 For Stable Operation - Coolant temperature coolant sensor circuit diagrams and
Signal rate of change circuit, short circuit to ground, short check engine coolant
below threshold circuit to power, open circuit temperature sensor 1
circuit for short circuit
to ground, short circuit
to power, open circuit
Check for related
coolant temperature
coolant sensor faults.
Check and install a new
thermostat as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0128- Coolant Thermostat Thermostat stuck open Check for related


00 (Coolant Temp Below Cooling fans running continuously or coolant temperature
Thermostat Regulating at a high duty coolant sensor faults
Temperature) - No sub Check cooling fans for
type information correct operation.
Repair as required
Check and install a new
thermostat as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0131- O2 Circuit Low Voltage Pre-catalyst oxygen sensor odd Check pre-catalyst
00 (Bank 1, Sensor 1) - No disconnected oxygen sensor odd
sub type information Pre-catalyst oxygen sensor odd connector is connected
variable circuit, short circuit to ground Refer to the electrical
Pre-catalyst oxygen sensor odd circuit diagrams and
variable circuit, open circuit check pre-catalyst
Pre-catalyst oxygen sensor odd heater oxygen sensor odd
fault variable circuit for short
Pre-catalyst oxygen sensor odd failure circuit to ground, open
circuit
Check pre-catalyst
oxygen sensor odd
heater circuit
Check and install a new
pre-catalyst oxygen
sensor odd as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0131- O2 Sensor Circuit Low NOTE: Check pre-catalyst


1A Voltage (Bank 1 Sensor 1) oxygen sensor odd
- Circuit resistance below - Circuit UHEGO_A_VARIABLE - connector is connected
threshold Refer to the electrical
Pre-catalyst oxygen sensor odd circuit diagrams and
disconnected check pre-catalyst
Pre-catalyst oxygen sensor odd oxygen sensor odd
variable circuit, short circuit to ground variable circuit for short
Pre-catalyst oxygen sensor odd circuit to ground, open
variable circuit, open circuit circuit
Pre-catalyst oxygen sensor odd heater Check pre-catalyst
fault oxygen sensor odd
Pre-catalyst oxygen sensor odd failure heater circuit
Check and install a new
pre-catalyst oxygen
sensor odd as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0132- O2 Circuit High Voltage Pre-catalyst oxygen sensor odd Check pre-catalyst
00 (Bank 1, Sensor 1) - No disconnected oxygen sensor odd
sub type information Pre-catalyst oxygen sensor odd connector is connected
variable circuit, short circuit to power Refer to the electrical
Pre-catalyst oxygen sensor odd circuit diagrams and
variable circuit, open circuit check pre-catalyst
Pre-catalyst oxygen sensor odd heater oxygen sensor odd
fault variable circuit for short
Pre-catalyst oxygen sensor odd failure circuit to power, open
circuit
Check pre-catalyst
oxygen sensor odd
heater circuit
Check and install a new
pre-catalyst oxygen
sensor odd as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0132- O2 Sensor Circuit High NOTE: Check pre-catalyst


1B Voltage (Bank 1 Sensor 1) oxygen sensor odd
- Circuit resistance above - Circuit UHEGO_A_VARIABLE - connector is connected
threshold Refer to the electrical
Pre-catalyst oxygen sensor odd circuit diagrams and
disconnected check pre-catalyst
Pre-catalyst oxygen sensor odd oxygen sensor odd
variable circuit, short circuit to power variable circuit for short
Pre-catalyst oxygen sensor odd circuit to power, open
variable circuit, open circuit circuit
Pre-catalyst oxygen sensor odd heater Check pre-catalyst
fault oxygen sensor odd
Pre-catalyst oxygen sensor odd failure heater circuit
Check and install a new
pre-catalyst oxygen
sensor odd as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0133- O2 Circuit Slow Response NOTE: Check pre-catalyst


00 (Bank 1, Sensor 1) - No oxygen sensor odd is
sub type information - Circuit UHEGO_A_VARIABLE - correctly installed in
exhaust manifold
Exhaust leak Check for and rectify
Pre-catalyst oxygen sensor odd to any exhaust leak
engine control module wiring shield between cylinder head
high resistance and catalytic converter
Fuel control system fault Refer to the electrical
Pre-catalyst oxygen sensor odd failure circuit diagrams and
check pre-catalyst
oxygen sensor odd to
engine control module
wiring shield for high
resistance
Check fuel control
system for failure
Check and install a new
pre-catalyst oxygen
sensor odd as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0134- O2 Circuit No Activity NOTE: Refer to the electrical


00 Detected (Bank 1, Sensor circuit diagrams and
1) - No sub type - Circuit UHEGO_A_VARIABLE - check pre-catalyst
information oxygen sensor odd
Pre-catalyst oxygen sensor odd circuit circuit for short circuit
short circuit to ground, short circuit to to ground, short circuit
power, open circuit to power, open circuit
Pre-catalyst oxygen sensor odd failure Check and install a new
pre-catalyst oxygen
sensor odd as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0137- O2 Circuit Low Voltage NOTE: Refer to the electrical


00 (Bank 1, Sensor 2) - No circuit diagrams and
sub type information - Circuit HEGO_SENSOR_A - check post catalyst
oxygen sensor - odd,
Post catalyst oxygen sensor - odd, sensing circuit for short
sensing circuit short circuit to ground, circuit to ground, high
high resistance, open circuit resistance, open circuit
Damaged or blocked catalyst Check for damaged or
Air leak between catalyst and exhaust blocked catalyst
manifold Check for air leak
Post catalyst oxygen sensor - odd, between catalyst and
failure exhaust manifold
Check and install new
post catalyst oxygen
sensor - odd, as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0138- O2 Circuit High Voltage NOTE: Refer to the electrical


00 (Bank 1, Sensor 2) - No circuit diagrams and
sub type information - Circuit HEGO_SENSOR_A - check post catalyst
oxygen sensor - odd,
Post catalyst oxygen sensor - odd, sensing circuit for short
sensing circuit short circuit to power circuit to power
Post catalyst oxygen sensor - odd, tip Check post catalyst
damaged, blocked, poisoned oxygen sensor - odd, tip
Catalyst blocked for damage, blockage,
Post catalyst oxygen sensor - odd, poisoned, install a new
failure sensor as required
Check for blocked
catalyst
Check and install new
catalyst as required.
Check and install new
post catalyst oxygen
sensor - odd, as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0139- O2 Circuit Slow Response NOTE: Check for excessive oil


00 (Bank 1, Sensor 2) - No consumption. Repair as
sub type information - Circuit HEGO_SENSOR_A - required
Check for related
Excessive oil consumption DTCs. Check post
Post catalyst oxygen sensor - odd, tip catalyst oxygen sensor -
damaged, blocked, poisoned odd, tip for damage,
blockage, poisoned,
install a new sensor as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0140- O2 Circuit No Activity NOTE: Refer to the electrical


00 Detected (Bank 1, Sensor circuit diagrams and
2) - No sub type - Circuit HEGO_SENSOR_A - check post catalyst
information oxygen sensor - odd,
Post catalyst oxygen sensor - odd, sensing circuit for short
sensing circuit short circuit to ground, circuit to ground, short
short circuit to power, high resistance, circuit to power, high
open circuit resistance, open circuit
Air leak between catalyst and exhaust Check for air leak
manifold between catalyst and
Post catalyst oxygen sensor - odd, tip exhaust manifold
damaged, blocked, poisoned Check post catalyst
Post catalyst oxygen sensor - odd, oxygen sensor - odd, tip
failure for damage, blockage,
poisoned, install a new
sensor as required
Check for excessive oil
consumption. Repair as
required
Check and install new
post catalyst oxygen
sensor - odd, as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0141- O2 Heater Circuit (Bank 1, NOTE: Using the Jaguar Land


00 Sensor 2) - No sub type Rover approved
information - Circuit HTR_HEGO_A - diagnostic equipment
check datalogger signal,
Post catalyst oxygen sensor - odd, Oxygen Sensor (O2S)
sensing circuit short circuit to ground, Heater Duty Cycle
short circuit to power, high resistance, Bank 1 Sensor 2
open circuit (0x03A2)
Air leak between catalyst and exhaust Refer to the electrical
manifold circuit diagrams and
Catalyst oxygen sensor heater circuit check post catalyst
control relay failure oxygen sensor - odd,
Post catalyst oxygen sensor - odd, sensing circuit for short
failure circuit to ground, short
circuit to power, high
resistance, open circuit
Check for air leak
between catalyst and
exhaust manifold
Refer to the electrical
circuit diagrams and
check catalyst oxygen
sensor heater circuit
control relay circuit for
short circuit to ground,
short circuit to power,
open circuit
Check and install a new
catalyst oxygen sensor
heater control relay, as
required. Check and
install new post catalyst
oxygen sensor - odd, as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0148- Fuel Delivery Error - Injector(s) circuit, short circuit to Check for related
65 Signal has too few ground, short circuit to power, high injector DTCs
transitions / events resistance Refer to the electrical
Injector(s) failure circuit diagrams and
Engine control module internal failure check injector(s) circuit
for, short circuit to
ground, short circuit to
power, high resistance
Check and install a new
injector(s) as required.
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0148- Fuel Delivery Error - Injector(s) circuit, short circuit to Check for related
66 Signal has too many ground, short circuit to power, high injector DTCs
transitions / events resistance Refer to the electrical
Injector(s) failure circuit diagrams and
Engine control module internal failure check injector(s) circuit
for, short circuit to
ground, short circuit to
power, high resistance
Check and install a new
injector(s) as required.
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0149- Fuel Timing Error - Signal Injector(s) circuit, short circuit to Check for related
32 low time < minimum ground, short circuit to power, high injector DTCs
resistance Refer to the electrical
Injector(s) failure circuit diagrams and
Engine control module internal failure check injector(s) circuit
for, short circuit to
ground, short circuit to
power, high resistance
Check and install a new
injector(s) as required.
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0149- Fuel Timing Error - Signal Injector(s) circuit, short circuit to Check for related
35 high time > maximum ground, short circuit to power, high injector DTCs
resistance Refer to the electrical
Injector(s) failure circuit diagrams and
Engine control module internal failure check injector(s) circuit
for, short circuit to
ground, short circuit to
power, high resistance
Check and install a new
injector(s) as required.
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0151- O2 Sensor Circuit Low NOTE: Refer to the electrical


1A Voltage (Bank 2 Sensor 1) circuit diagrams and
- Circuit resistance below - Circuit UHEGO_B_VARIABLE - check pre-catalyst
threshold oxygen sensor - even
Pre-catalyst oxygen sensor - even circuit for short circuit
circuit short circuit to ground to ground
Pre-catalyst oxygen sensor - even Check and install new
failure pre catalyst oxygen
sensor - even. Refer to
the warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0152- O2 Sensor Circuit Low NOTE: Refer to the electrical


1B Voltage (Bank 2 Sensor 1) circuit diagrams and
- Circuit resistance above - Circuit UHEGO_B_VARIABLE - check pre-catalyst
threshold oxygen sensor - even
Pre-catalyst oxygen sensor - even circuit for short circuit
circuit short circuit to power, to power, disconnected
disconnected Check and install new
Pre-catalyst oxygen sensor - even pre catalyst oxygen
failure sensor - even. Refer to
the warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0153- O2 Circuit Slow Response NOTE: Check pre-catalyst


00 (Bank 2, Sensor 1) - No oxygen sensor even is
sub type information - Circuit UHEGO_B_VARIABLE - correctly installed in
exhaust manifold
Exhaust leak Check for and rectify
Pre-catalyst oxygen sensor even to any exhaust leak
engine control module wiring shield between cylinder head
high resistance and catalytic converter
Pre-catalyst oxygen sensor even to Refer to the electrical
engine control module signal circuit circuit diagrams and
short circuit to ground check pre-catalyst
Fuel control system fault oxygen sensor even to
Pre-catalyst oxygen sensor even failure engine control module
wiring shield for high
resistance
Refer to the electrical
circuit diagrams and
check Pre-catalyst
oxygen sensor even to
engine control module
signal circuit for short
circuit to ground
Check fuel control
system for failure
Check and install a new
pre-catalyst oxygen
sensor even as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component
P0154- O2 Circuit No Activity NOTE: Check pre-catalyst
00 Detected (Bank 2, Sensor oxygen sensor even is
1) - No sub type - Circuit UHEGO_B_VARIABLE - correctly installed in
information exhaust manifold
Pre-catalyst oxygen sensor even to Refer to the electrical
engine control module wiring shield circuit diagrams and
high resistance check pre-catalyst
Pre-catalyst oxygen sensor even to oxygen sensor even to
engine control module signal circuit engine control module
short circuit to ground, high resistance, wiring shield for high
open circuit resistance
Pre-catalyst oxygen sensor even failure Refer to the electrical
circuit diagrams and
check pre-catalyst
oxygen sensor even to
engine control module
signal circuit for short
circuit to ground, high
resistance, open circuit
Check and install a new
pre-catalyst oxygen
sensor even as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0157- O2 Circuit Low Voltage NOTE: Refer to the electrical


00 (Bank 2, Sensor 2) - No circuit diagrams and
sub type information - Circuit HEGO_SENSOR_B - check post catalyst
oxygen sensor - even,
Post catalyst oxygen sensor - even, sensing circuit for short
sensing circuit short circuit to ground, circuit to ground, high
high resistance, open circuit resistance, open circuit
Air leak between catalyst and exhaust Check for air leak
manifold between catalyst and
Post catalyst oxygen sensor - even, tip exhaust manifold
damaged, blocked, poisoned Check post catalyst
Post catalyst oxygen sensor - even, oxygen sensor - even,
failure tip for damage,
blockage, poisoned
Check and install new
post catalyst oxygen
sensor - even, as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component
P0158- O2 Circuit High Voltage NOTE: Refer to the electrical
00 (Bank 2, Sensor 2) - No circuit diagrams and
sub type information - Circuit HEGO_SENSOR_B - check post catalyst
oxygen sensor - even,
Post catalyst oxygen sensor - even, sensing circuit for short
sensing circuit short circuit to power circuit to power
Post catalyst oxygen sensor - even, tip Check post catalyst
damaged, blocked, poisoned oxygen sensor - even,
Post catalyst oxygen sensor - even, tip for damage,
failure blockage, poisoned
Check and install new
post catalyst oxygen
sensor - even, as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0159- O2 Circuit Slow Response NOTE: Check for excessive oil


00 (Bank 2, Sensor 2) - No consumption, repair as
sub type information - Circuit HEGO_SENSOR_B - required
Check post catalyst
Excessive oil consumption oxygen sensor - even,
Post catalyst oxygen sensor - even, tip tip for damage,
damaged, blocked, poisoned blockage, poisoned,
Post catalyst oxygen sensor - even, install a new sensor as
failure required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0160- O2 Circuit No Activity NOTE: Refer to the electrical


00 Detected (Bank 2, Sensor circuit diagrams and
2) - No sub type - Circuit HEGO_SENSOR_B - check post catalyst
information oxygen sensor - even,
Post catalyst oxygen sensor - even, sensing circuit for short
sensing circuit short circuit to ground, circuit to ground, short
short circuit to power, high resistance, circuit to power, high
open circuit resistance, open circuit
Air leak between catalyst and exhaust Check for air leak
manifold between catalyst and
Post catalyst oxygen sensor - even, tip exhaust manifold
damaged, blocked, poisoned Check post catalyst
Post catalyst oxygen sensor - even, oxygen sensor - even,
failure tip for damage,
blockage, poisoned
Check and install new
post catalyst oxygen
sensor - even, as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0161- O2 Heater Circuit (Bank 2, NOTE: Refer to the electrical


00 Sensor 2) - No sub type circuit diagrams and
information - Circuit HTR_HEGO_B - check post catalyst
oxygen sensor - even,
Post catalyst oxygen sensor - even, sensing circuit for short
sensing circuit short circuit to ground, circuit to ground, short
short circuit to power, high resistance, circuit to power, high
open circuit resistance, open circuit
Post catalyst oxygen sensor - even, Refer to the electrical
sensing circuit fuse failure circuit diagrams and
Catalyst oxygen sensor heater circuit check Post catalyst
control relay failure oxygen sensor - even,
Post catalyst oxygen sensor - even, sensing circuit fuse,
failure replace as required
Refer to the electrical
circuit diagrams and
check catalyst oxygen
sensor heater circuit
control relay circuit for
short circuit to ground,
short circuit to power,
open circuit
Check and install a new
catalyst oxygen sensor
heater control relay, as
required. Check and
install new post catalyst
oxygen sensor - even, as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0171- System Too Lean (Bank 1) Air leak upstream of MAF/IAT sensor Refer to the electrical
00 - No sub type information bank 1 circuit diagrams and
MAF/IAT sensor bank 1 circuit failure check MAF/IAT sensor
MAF/IAT sensor bank 1 failure circuit, for short circuit
Pre-catalyst oxygen sensor odd circuit to ground, short circuit
failure power, high resistance,
Pre-catalyst oxygen sensor odd failure open circuit
Post-catalyst oxygen sensor odd circuit Refer to the electrical
failure circuit diagrams and
Post-catalyst oxygen sensor odd failure check post catalyst
oxygen sensor - even,
sensing circuit for short
circuit to ground, short
circuit power, high
resistance, open circuit
Check for leak from air
intake system
Check for additional
MAF/IAT sensor bank
1 related DTCs and
refer to relevant DTC
index
Check for additional
pre-catalyst oxygen
sensor odd related
DTCs and refer to
relevant DTC index
Check for additional
post-catalyst oxygen
sensor odd related
DTCs and refer to
relevant DTC index

P0172- System Too Rich (Bank 1) Restricted air cleaner Refer to the electrical
00 - No sub type information Leaking fuel injector(s) circuit diagrams and
MAF/IAT sensor bank 1 failure check MAF/IAT sensor
Pre-catalyst oxygen sensor odd circuit circuit, for short circuit
failure to ground, short circuit
Pre-catalyst oxygen sensor odd failure power, high resistance,
Post-catalyst oxygen sensor odd circuit open circuit
failure Refer to the electrical
Post-catalyst oxygen sensor odd failure circuit diagrams and
check post catalyst
oxygen sensor - even,
sensing circuit for short
circuit to ground, short
circuit power, high
resistance, open circuit
Check air cleaner
element is free from
restriction
Check for leaking
injectors, install new
injector(s) as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component
Check for additional
MAF/IAT sensor bank
1 related DTCs and
refer to relevant DTC
index
Check for additional
pre-catalyst oxygen
sensor odd related
DTCs and refer to
relevant DTC index
Check for additional
post-catalyst oxygen
sensor odd related
DTCs and refer to
relevant DTC index

P0174- System Too Lean (Bank 2) Air leak upstream of MAF/IAT sensor Refer to the electrical
00 - No sub type information bank 2 circuit diagrams and
MAF/IAT sensor bank 2 circuit failure check MAF/IAT sensor
MAF/IAT sensor bank 2 failure circuit, for short circuit
Pre-catalyst oxygen sensor even circuit to ground, short circuit
failure power, high resistance,
Pre-catalyst oxygen sensor even failure open circuit
Post-catalyst oxygen sensor even Refer to the electrical
circuit failure circuit diagrams and
Post-catalyst oxygen sensor even check post catalyst
failure oxygen sensor - even,
sensing circuit for short
circuit to ground, short
circuit power, high
resistance, open circuit
Check for leak from air
intake system
Check for additional
MAF/IAT sensor bank
2 related DTCs and
refer to relevant DTC
index
Check for additional
pre-catalyst oxygen
sensor even related
DTCs and refer to
relevant DTC index
Check for additional
post-catalyst oxygen
sensor even related
DTCs and refer to
relevant DTC index

P0175- System Too Rich (Bank 2) Restricted air cleaner Refer to the electrical
00 - No sub type information Leaking fuel injector(s) circuit diagrams and
MAF/IAT sensor bank 2 circuit failure check MAF/IAT sensor
MAF/IAT sensor bank 2 failure circuit, for short circuit
Pre-catalyst oxygen sensor even circuit to ground, short circuit
failure power, high resistance,
Pre-catalyst oxygen sensor even failure open circuit
Post-catalyst oxygen sensor even Refer to the electrical
circuit failure circuit diagrams and
Post-catalyst oxygen sensor even check post catalyst
failure oxygen sensor - even,
sensing circuit for short
circuit to ground, short
circuit power, high
resistance, open circuit
Check for leak from air
intake system
Check for additional
MAF/IAT sensor bank
2 related DTCs and
refer to relevant DTC
index
Check for additional
pre-catalyst oxygen
sensor even related
DTCs and refer to
relevant DTC index
Check for additional
post-catalyst oxygen
sensor even related
DTCs and refer to
relevant DTC index

P018B- Fuel Pressure Sensor B NOTE: Using the Jaguar Land


29 Circuit Range/Performance Rover approved
- Signal invalid - Circuit diagnostic equipment
LOW_PRESS_FUEL_PRESS_SENSOR - check datalogger signal,
Fuel Rail Pressure -
Fuel Filter or fuel system restriction Low Range Sensor
Fuel system leak Voltage (0x0376)
Fuel pump pressure sensor circuit short Check for related fuel
circuit to ground, short circuit to pump DTCs
power, open circuit, high resistance Check the fuel system
Fuel pump pressure sensor failure for restrictions or
blockages
Refer to the electrical
circuit diagrams and
check fuel pump
pressure sensor circuit
for short circuit to
power, open circuit,
high resistance
Check and install a new
fuel pump pressure
sensor as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P018C- Fuel Pressure Sensor B NOTE: Using the Jaguar Land


00 Circuit Low - No sub type Rover approved
information - Circuit diagnostic equipment
LOW_PRESS_FUEL_PRESS_SENSOR - check datalogger signal,
Fuel Rail Pressure -
Fuel pump pressure sensor circuit short Low Range Sensor
circuit to ground, short circuit to Voltage (0x0376)
power, open circuit, high resistance Refer to the electrical
Fuel pump pressure sensor failure circuit diagrams and
check fuel pump
pressure sensor circuit
for short circuit to
power, short circuit to
ground, open circuit,
high resistance
Check and install a new
fuel pump pressure
sensor as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P018D- Fuel Pressure Sensor B NOTE: Using the Jaguar Land


00 Circuit High - No sub type Rover approved
information - Circuit diagnostic equipment
LOW_PRESS_FUEL_PRESS_SENSOR - check datalogger signal,
Fuel Rail Pressure -
Fuel pump pressure sensor circuit short Low Range Sensor
circuit to ground, short circuit to Voltage (0x0376)
power, open circuit, high resistance Refer to the electrical
Fuel pump pressure sensor failure circuit diagrams and
check fuel pump
pressure sensor circuit
for short circuit to
power, short circuit to
ground, open circuit,
high resistance
Check and install a new
fuel pump pressure
sensor as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0191- Fuel Rail Pressure Sensor NOTE: Using the Jaguar Land
00 A Circuit Rover approved
Range/Performance - No - Circuit FUEL_HIGH_PRESS_SENSOR - diagnostic equipment
sub type information check datalogger signal,
Fuel rail pressure sensor short circuit Fuel Rail Pressure
to ground, short circuit to power, open Sensor - High Range
circuit, high resistance Sensor Voltage
Fuel rail pressure sensor A failure (0x0377)
Refer to the electrical
circuit diagrams and
check fuel rail pressure
sensor A circuit for
short circuit to power,
short circuit to ground,
high resistance, open
circuit, terminal damage
or corrosion
Check and install a new
fuel rail pressure sensor
A as required. Refer to
the warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0192- Fuel Rail Pressure Sensor NOTE: Using the Jaguar Land
00 A Circuit Low - No sub Rover approved
type information - Circuit FUEL_HIGH_PRESS_SENSOR - diagnostic equipment
check datalogger signal,
Fuel rail pressure sensor short circuit Fuel Rail Pressure
to ground, short circuit to power, open Sensor - High Range
circuit, high resistance Sensor Voltage
Fuel rail pressure sensor A failure (0x0377)
Refer to the electrical
circuit diagrams and
check fuel rail pressure
sensor A circuit for
short circuit to power,
short circuit to ground,
high resistance, open
circuit, terminal damage
or corrosion
Check and install a new
fuel rail pressure sensor
A as required. Refer to
the warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0193- Fuel Rail Pressure Sensor NOTE: Using the Jaguar Land
00 A Circuit High - No sub Rover approved
type information - Circuit FUEL_HIGH_PRESS_SENSOR - diagnostic equipment
check datalogger signal,
Fuel rail pressure sensor short circuit Fuel Rail Pressure
to ground, short circuit to power, open Sensor - High Range
circuit, high resistance Sensor Voltage
Fuel rail pressure sensor A failure (0x0377)
Refer to the electrical
circuit diagrams and
check fuel rail pressure
sensor A circuit for
short circuit to power,
short circuit to ground,
high resistance, open
circuit, terminal damage
or corrosion
Check and install a new
fuel rail pressure sensor
A as required. Refer to
the warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0196- Engine Oil Temperature NOTE: Using the Jaguar Land


23 Sensor Range/Performance Rover approved
- Signal stuck low - Circuit OIL_QUALITY_SENSOR - diagnostic equipment
check datalogger signal,
Oil temperature - level sensor circuit Sump Oil Temperature -
short circuit to ground, high resistance Measured (0x03F3)
Oil temperature - level sensor failure Refer to the electrical
circuit diagrams and
check oil temperature -
level sensor circuit for
short circuit to ground,
intermittent high
resistance
Check and install new
oil temperature - level
sensor as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0196- Engine Oil Temperature NOTE: Using the Jaguar Land


24 Sensor Range/Performance Rover approved
- Signal stuck high - Circuit OIL_QUALITY_SENSOR - diagnostic equipment
check datalogger signal,
Oil temperature - level sensor circuit Sump Oil Temperature -
short circuit to power Measured (0x03F3)
Oil temperature - level sensor failure Refer to the electrical
circuit diagrams and
check oil temperature -
level sensor circuit for
intermittent short circuit
to power
Check and install new
oil temperature - level
sensor as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0200- Injector Circuit - System Engine control module injector circuit Refer to the electrical
04 internal failures power failure circuit diagrams and
Engine control module power supply check engine control
open circuit module injector power
Engine control module ground supply circuit for open circuit
open circuit Refer to the electrical
circuit diagrams and
check the power and
ground connections to
the module
Check for misfire
DTCs, if present
suspect the engine
control module

P0200- Injector Circuit - Internal Engine control module failure Check for misfire
49 electronic failure DTCs, if present
suspect the engine
control module
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0200- Injector Circuit - Over Engine control module failure If combined with
4B temperature misfire codes for one or
both injector sets, then
no service rectification
is proposed
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component
P0201- Cylinder 1 Injector Circuit NOTE: Refer to the electrical
13 / Open - Circuit open circuit diagrams and
- Circuit INJECTOR_1A - check fuel injector no.1
INJECTOR_1A_COMMON - circuit for open circuit,
disconnected injector,
Fuel injector no.1 circuit open circuit high resistance
Injector disconnected
Injector high resistance

P0202- Cylinder 2 Injector Circuit NOTE: Refer to the electrical


13 / Open - Circuit open circuit diagrams and
- Circuit INJECTOR_1B - check fuel injector no.2
INJECTOR_1B_COMMON - circuit for open circuit,
disconnected injector,
Fuel injector no.2 circuit open circuit high resistance
Injector disconnected
Injector high resistance

P0203- Cylinder 3 Injector Circuit NOTE: Refer to the electrical


13 / Open - Circuit open circuit diagrams and
- Circuit INJECTOR_2A - check fuel injector no.3
INJECTOR_2A_COMMON - circuit for open circuit,
disconnected injector,
Fuel injector no.3 circuit open circuit high resistance
Injector disconnected
Injector high resistance

P0204- Cylinder 4 Injector Circuit NOTE: Refer to the electrical


13 / Open - Circuit open circuit diagrams and
- Circuit INJECTOR_2B - check fuel injector no.4
INJECTOR_2B_COMMON - circuit for open circuit,
disconnected injector,
Fuel injector no.4 circuit open circuit high resistance
Injector disconnected
Injector high resistance

P0205- Cylinder 5 Injector Circuit NOTE: Refer to the electrical


13 / Open - Circuit open circuit diagrams and
- Circuit INJECTOR_3A - check fuel injector no.5
INJECTOR_3A_COMMON - circuit for open circuit,
disconnected injector,
Fuel injector no.5 circuit open circuit high resistance
Injector disconnected
Injector high resistance

P0206- Cylinder 6 Injector Circuit NOTE: Refer to the electrical


13 / Open - Circuit open circuit diagrams and
- Circuit INJECTOR_3B - check fuel injector no.6
INJECTOR_3B_COMMON - circuit for open circuit,
disconnected injector,
Fuel injector no.6 circuit open circuit high resistance
Injector disconnected
Injector high resistance

P0207- Cylinder 7 Injector Circuit NOTE: Refer to the electrical


13 / Open - Circuit open circuit diagrams and
- Circuit INJECTOR_4A - check fuel injector no.7
INJECTOR_4A_COMMON - circuit for open circuit,
disconnected injector,
Fuel injector no.7 circuit open circuit high resistance
Injector disconnected
Injector high resistance

P0208- Cylinder 8 Injector Circuit NOTE: Refer to the electrical


13 / Open - Circuit open circuit diagrams and
- Circuit INJECTOR_4B - check fuel injector no.8
INJECTOR_4B_COMMON - circuit for open circuit,
disconnected injector,
Fuel injector no.8 circuit open circuit high resistance
Injector disconnected
Injector high resistance

P0222- Throttle/Pedal Position NOTE: Refer to the electrical


00 Sensor/Switch B Circuit circuit diagrams and
Low - No sub type - Circuit check throttle/pedal
information THROTTLE_POSITION_SENSOR_2 - position sensor/switch
B circuit for open
Throttle/pedal position sensor/switch B circuit, short circuit to
circuit open circuit, short circuit to ground
ground Check and install a new
Throttle/pedal position sensor/switch B throttle/pedal position
failure sensor/switch B as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0223- Throttle/Pedal Position NOTE: Refer to the electrical


00 Sensor/Switch B Circuit circuit diagrams and
High - No sub type - Circuit check throttle/pedal
information THROTTLE_POSITION_SENSOR_2 - position sensor/switch
B circuit for open
Throttle/pedal position sensor/switch B circuit, short circuit to
circuit open circuit, short circuit to power
power Check and install a new
Throttle/pedal position sensor/switch B throttle/pedal position
failure sensor/switch B as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0231- Fuel Pump Secondary NOTE: Check for related DTCs


23 Circuit Low - Signal stuck P0232-24
low - Circuit Refer to the electrical
HIGH_PRESS_FUEL_PUMP_CTRL_2NEG circuit diagrams and
- check fuel pump driver
HIGH_PRESS_FUEL_PUMP_CTRL_2POS module signal circuit
- for short circuit to
ground, open circuit
Fuel pump driver module signal circuit Refer to the electrical
short circuit to ground, open circuit circuit diagrams and
Fuel pump driver module is not check fuel pump driver
energized with the ignition on module is energized
Fuel pump driver module failure with the ignition on.
Repair as required
Using the Jaguar Land
Rover approved
diagnostic equipment,
perform routine - Inline
diagnostic unit 2 non-
intrusive test - Low
pressure fuel pump
Check and install a new
fuel pump driver
module as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0232- Fuel Pump Secondary NOTE: Check for related DTCs


24 Circuit Low - Signal stuck P0231-23
high - Circuit Refer to the electrical
HIGH_PRESS_FUEL_PUMP_CTRL_2NEG circuit diagrams and
- check fuel pump driver
HIGH_PRESS_FUEL_PUMP_CTRL_2POS module signal circuit
- for short circuit to
ground, open circuit
Fuel pump driver module signal circuit Refer to the electrical
short circuit to ground, open circuit circuit diagrams and
Fuel pump driver module is not check fuel pump driver
energized with the ignition on module is energized
Fuel pump driver module failure with the ignition on.
Repair as required
Using the Jaguar Land
Rover approved
diagnostic equipment,
perform routine - Inline
diagnostic unit 2 non-
intrusive test - Low
pressure fuel pump
Check and install a new
fuel pump driver
module as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0236- Turbocharger/Supercharger NOTE: Check air cleaner


00 Boost Sensor A Circuit element is free from
Range/Performance - No - Circuit TMAP_PRESS_SENSOR - restriction
sub type information Check for leak from air
Blocked air cleaner element(s) intake system, rectify as
Intake manifold air leak required
Manifold absolute pressure sensor 2 Refer to the electrical
circuit short circuit to ground, short circuit diagrams and
circuit to power, open circuit, high check manifold absolute
resistance pressure sensor 2 circuit
Engine breather leak for short circuit to
Carbon build up on throttle plate ground, short circuit to
Exhaust system blocked power, open circuit,
Manifold absolute pressure sensor 2 high resistance
failure Ensure the engine
BARO sensor failure breather system is
correctly installed and
in serviceable condition
Make sure throttle blade
is clean of carbon
Check for blocked
exhaust
Check for related
BARO sensor DTC
P0069-29
Check and install a new
manifold absolute
pressure sensor 2 as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0237- Turbocharger/Supercharger NOTE: Refer to the electrical


00 Boost Sensor A Circuit circuit diagrams and
Low - No sub type - Circuit TMAP_PRESS_SENSOR - check manifold absolute
information pressure sensor 2 circuit
Manifold absolute pressure sensor 2 for short circuit to
circuit short circuit to ground, open ground, open circuit,
circuit, high resistance high resistance
Manifold absolute pressure sensor 2 Check and install a new
failure manifold absolute
pressure sensor 2 as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0238- Turbocharger/Supercharger NOTE: Refer to the electrical


00 Boost Sensor A Circuit circuit diagrams and
High - No sub type - Circuit TMAP_PRESS_SENSOR - check manifold absolute
information pressure sensor 2 circuit
Manifold absolute pressure sensor for short circuit to
circuit 2 short circuit to power, open power, open circuit,
circuit, high resistance high resistance
Manifold absolute pressure sensor 2 Check and install a new
failure manifold absolute
pressure sensor 2 as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0251- Injection Pump Fuel NOTE: Refer to the electrical


13 Metering Control A - circuit diagrams and
Circuit open - Circuit check fuel rail pressure
HIGH_PRESS_FUEL_PUMP_CTRL_1NEG sensor circuit for open
- circuit
HIGH_PRESS_FUEL_PUMP_CTRL_2NEG
-

Fuel rail pressure sensor circuit, open


circuit

P0253- Injection Pump Fuel NOTE: Refer to the electrical


11 Metering Control A Low - circuit diagrams and
Circuit short to ground - Circuit check fuel rail pressure
HIGH_PRESS_FUEL_PUMP_CTRL_1NEG sensor circuit for short
- circuit to ground
HIGH_PRESS_FUEL_PUMP_CTRL_2NEG
-

Fuel rail pressure sensor circuit, short


circuit to ground

P0254- Injection Pump Fuel NOTE: Refer to the electrical


12 Metering Control A High - circuit diagrams and
Circuit short to battery - Circuit check fuel rail pressure
HIGH_PRESS_FUEL_PUMP_CTRL_1NEG sensor circuit for short
- circuit to power
HIGH_PRESS_FUEL_PUMP_CTRL_2NEG
-

Fuel rail pressure sensor circuit, short


circuit to power

P0256- Injection Pump Fuel NOTE: Refer to the electrical


13 Metering Control B - circuit diagrams and
Circuit open - Circuit check fuel rail pressure
HIGH_PRESS_FUEL_PUMP_CTRL_1NEG sensor circuit for open
- circuit
HIGH_PRESS_FUEL_PUMP_CTRL_2NEG
-

Fuel rail pressure sensor circuit, open


circuit

P0258- Injection Pump Fuel NOTE: Refer to the electrical


11 Metering Control B Low - circuit diagrams and
Circuit short to ground - Circuit check fuel rail pressure
HIGH_PRESS_FUEL_PUMP_CTRL_1NEG sensor circuit for short
- circuit to ground
HIGH_PRESS_FUEL_PUMP_CTRL_2NEG
-

Fuel rail pressure sensor circuit, short


circuit to ground

P0259- Injection Pump Fuel NOTE: Refer to the electrical


12 Metering Control B High - circuit diagrams and
Circuit short to battery - Circuit check fuel rail pressure
HIGH_PRESS_FUEL_PUMP_CTRL_1NEG sensor circuit for short
- circuit to power
HIGH_PRESS_FUEL_PUMP_CTRL_2NEG
-

Fuel rail pressure sensor circuit, short


circuit to power

P025C- Fuel Pump Module Control NOTE: Refer to the electrical


14 Circuit Low - Circuit short circuit diagrams and
to ground or open - Circuit FPDM control - check fuel pump driver
module circuit short
Fuel pump driver module control circuit to ground, open
circuit, short circuit to ground, open circuit
circuit Using the Jaguar Land
Rover approved
diagnostic equipment,
perform routine - Inline
diagnostic unit 2 non-
intrusive test - Low
pressure fuel pump

P025D- Fuel Pump Module Control NOTE: Refer to the electrical


12 Circuit High - Circuit short circuit diagrams and
to battery - Circuit FPDM control - check fuel pump driver
module circuit short
Fuel pump driver module control circuit to power
circuit, short circuit to power Using the Jaguar Land
Rover approved
diagnostic equipment,
perform routine - Inline
diagnostic unit 2 non-
intrusive test - Low
pressure fuel pump

P0261- Cylinder 1 Injector Circuit NOTE: Refer to the electrical


11 Low - Circuit short to circuit diagrams and
ground - Circuit INJECTOR_1A - check fuel injector no.1
INJECTOR_1A_COMMON - circuit for short circuit
to ground
Fuel injector no.1 circuit short circuit
to ground

P0261- Cylinder 1 Injector Circuit NOTE: Refer to the electrical


12 Low - Circuit short to circuit diagrams and
battery - Circuit INJECTOR_1A - check fuel injector no.1
INJECTOR_1A_COMMON - circuit for short circuit
to power
Fuel injector no.1 circuit short circuit
to power

P0262- Cylinder 1 Injector Circuit NOTE: Refer to the electrical


01 High - General electrical circuit diagrams and
failure - Circuit INJECTOR_1A - check fuel injector no.1
INJECTOR_1A_COMMON - circuit for short circuit
to ground, short circuit
Fuel injector no.1 circuit short circuit to power
to ground, short circuit to power

P0262- Cylinder 1 Injector Circuit NOTE: Refer to the electrical


12 High - Circuit short to circuit diagrams and
battery - Circuit INJECTOR_1A - check fuel injector no.1
INJECTOR_1A_COMMON - circuit for short circuit
to power
Fuel injector no.1 circuit short circuit
to power

P0264- Cylinder 2 Injector Circuit NOTE: Refer to the electrical


11 Low - Circuit short to circuit diagrams and
ground - Circuit INJECTOR_1B - check fuel injector no.2
INJECTOR_1B_COMMON - circuit for short circuit
to ground
Fuel injector no.2 circuit short circuit
to ground

P0264- Cylinder 2 Injector Circuit NOTE: Refer to the electrical


12 Low - Circuit short to circuit diagrams and
battery - Circuit INJECTOR_1B - check fuel injector no.2
INJECTOR_1B_COMMON - circuit for short circuit
to power
Fuel injector no.2 circuit short circuit
to power

P0265- Cylinder 2 Injector Circuit NOTE: Refer to the electrical


01 High - General electrical circuit diagrams and
failure - Circuit INJECTOR_1B - check fuel injector no.2
INJECTOR_1B_COMMON - circuit for short circuit
to ground, short circuit
Fuel injector no.2 circuit short circuit to power
to ground, short circuit to power
P0265- Cylinder 2 Injector Circuit NOTE: Refer to the electrical
12 High - Circuit short to circuit diagrams and
battery - Circuit INJECTOR_1B - check fuel injector no.2
INJECTOR_1B_COMMON - circuit for short circuit
to power
Fuel injector no.2 circuit short circuit
to power

P0267- Cylinder 3 Injector Circuit NOTE: Refer to the electrical


11 Low - Circuit short to circuit diagrams and
ground - Circuit INJECTOR_2A - check fuel injector no.3
INJECTOR_2A_COMMON - circuit for short circuit
to ground
Fuel injector no.3 circuit short circuit
to ground

P0267- Cylinder 3 Injector Circuit NOTE: Refer to the electrical


12 Low - Circuit short to circuit diagrams and
battery - Circuit INJECTOR_2A - check fuel injector no.3
INJECTOR_2A_COMMON - circuit for short circuit
to power
Fuel injector no.3 circuit short circuit
to power

P0268- Cylinder 3 Injector Circuit NOTE: Refer to the electrical


01 High - General electrical circuit diagrams and
failure - Circuit INJECTOR_2A - check fuel injector no.3
INJECTOR_2A_COMMON - circuit for short circuit
to ground, short circuit
Fuel injector no.3 circuit short circuit to power
to ground, short circuit to power

P0268- Cylinder 3 Injector Circuit NOTE: Refer to the electrical


12 High - Circuit short to circuit diagrams and
battery - Circuit INJECTOR_2A - check fuel injector no.3
INJECTOR_2A_COMMON - circuit for short circuit
to power
Fuel injector no.3 circuit short circuit
to power

P0270- Cylinder 4 Injector Circuit NOTE: Refer to the electrical


11 Low - Circuit short to circuit diagrams and
ground - Circuit INJECTOR_2B - check fuel injector no.4
INJECTOR_2B_COMMON - circuit for short circuit
to ground
Fuel injector no.4 circuit short circuit
to ground

P0270- Cylinder 4 Injector Circuit NOTE: Refer to the electrical


12 Low - Circuit short to circuit diagrams and
battery - Circuit INJECTOR_2B - check fuel injector no.4
INJECTOR_2B_COMMON - circuit for short circuit
to power
Fuel injector no.4 circuit short circuit
to power

P0271- Cylinder 4 Injector Circuit NOTE: Refer to the electrical


01 High - General electrical circuit diagrams and
failure - Circuit INJECTOR_2B - check fuel injector no.4
INJECTOR_2B_COMMON - circuit for short circuit
to ground, short circuit
Fuel injector no.4 circuit short circuit to power
to ground, short circuit to power

P0271- Cylinder 4 Injector Circuit NOTE: Refer to the electrical


12 High - Circuit short to circuit diagrams and
battery - Circuit INJECTOR_2B - check fuel injector no.4
INJECTOR_2B_COMMON - circuit for short circuit
to power
Fuel injector no.4 circuit short circuit
to power

P0273- Cylinder 5 Injector Circuit NOTE: Refer to the electrical


11 Low - Circuit short to circuit diagrams and
ground - Circuit INJECTOR_3A - check fuel injector no.5
INJECTOR_3A_COMMON - circuit for short circuit
to ground
Fuel injector no.5 circuit short circuit
to ground

P0273- Cylinder 5 Injector Circuit NOTE: Refer to the electrical


12 Low - Circuit short to circuit diagrams and
battery - Circuit INJECTOR_3A - check fuel injector no.5
INJECTOR_3A_COMMON - circuit for short circuit
to power
Fuel injector no.5 circuit short circuit
to power

P0274- Cylinder 5 Injector Circuit NOTE: Refer to the electrical


01 High - General electrical circuit diagrams and
failure - Circuit INJECTOR_3A - check fuel injector no.5
INJECTOR_3A_COMMON - circuit for short circuit
to ground, short circuit
Fuel injector no.5 circuit short circuit to power
to ground, short circuit to power

P0274- Cylinder 5 Injector Circuit NOTE: Refer to the electrical


12 High - Circuit short to circuit diagrams and
battery - Circuit INJECTOR_3A - check fuel injector no.5
INJECTOR_3A_COMMON - circuit for short circuit
to power
Fuel injector no.5 circuit short circuit
to power

P0276- Cylinder 6 Injector Circuit NOTE: Refer to the electrical


11 Low - Circuit short to circuit diagrams and
ground - Circuit INJECTOR_3B - check fuel injector no.6
INJECTOR_3B_COMMON - circuit for short circuit
to ground
Fuel injector no.6 circuit short circuit
to ground

P0276- Cylinder 6 Injector Circuit NOTE: Refer to the electrical


12 Low - Circuit short to circuit diagrams and
battery - Circuit INJECTOR_3B - check fuel injector no.6
INJECTOR_3B_COMMON - circuit for short circuit
to power
Fuel injector no.6 circuit short circuit
to power

P0277- Cylinder 6 Injector Circuit NOTE: Refer to the electrical


01 High - General electrical circuit diagrams and
failure - Circuit INJECTOR_3B - check fuel injector no.6
INJECTOR_3B_COMMON - circuit for short circuit
to ground, short circuit
Fuel injector no.6 circuit short circuit to power
to ground, short circuit to power

P0277- Cylinder 6 Injector Circuit NOTE: Refer to the electrical


12 High - Circuit short to circuit diagrams and
battery - Circuit INJECTOR_3B - check fuel injector no.6
INJECTOR_3B_COMMON - circuit for short circuit
to power
Fuel injector no.6 circuit short circuit
to power

P0279- Cylinder 7 Injector Circuit NOTE: Refer to the electrical


11 Low - Circuit short to circuit diagrams and
ground - Circuit INJECTOR_4A - check fuel injector no.7
INJECTOR_4A_COMMON - circuit for short circuit
to ground
Fuel injector no.7 circuit short circuit
to ground

P0279- Cylinder 7 Injector Circuit NOTE: Refer to the electrical


12 Low - Circuit short to circuit diagrams and
battery - Circuit INJECTOR_4A - check fuel injector no.7
INJECTOR_4A_COMMON - circuit for short circuit
to power
Fuel injector no.7 circuit short circuit
to power

P0280- Cylinder 7 Injector Circuit NOTE: Refer to the electrical


01 High - General electrical circuit diagrams and
failure - Circuit INJECTOR_4A - check fuel injector no.7
INJECTOR_4A_COMMON - circuit for short circuit
to ground, short circuit
Fuel injector no.7 circuit short circuit to power
to ground, short circuit to power

P0280- Cylinder 7 Injector Circuit NOTE: Refer to the electrical


12 High - Circuit short to circuit diagrams and
battery - Circuit INJECTOR_4A - check fuel injector no.7
INJECTOR_4A_COMMON - circuit for short circuit
to power
Fuel injector no.7 circuit short circuit
to power

P0282- Cylinder 8 Injector Circuit NOTE: Refer to the electrical


11 Low - Circuit short to circuit diagrams and
ground - Circuit INJECTOR_4B - check fuel injector no.8
INJECTOR_4B_COMMON - circuit for short circuit
to ground
Fuel injector no.8 circuit short circuit
to ground

P0282- Cylinder 8 Injector Circuit NOTE: Refer to the electrical


12 Low - Circuit short to circuit diagrams and
battery - Circuit INJECTOR_4B - check fuel injector no.8
INJECTOR_4B_COMMON - circuit for short circuit
to power
Fuel injector no.8 circuit short circuit
to power

P0283- Cylinder 8 Injector Circuit NOTE: Refer to the electrical


01 High - General electrical circuit diagrams and
failure - Circuit INJECTOR_4B - check fuel injector no.8
INJECTOR_4B_COMMON - circuit for short circuit
to ground, short circuit
Fuel injector no.8 circuit short circuit to power
to ground, short circuit to power

P0283- Cylinder 8 Injector Circuit NOTE: Refer to the electrical


12 High - Circuit short to circuit diagrams and
battery - Circuit INJECTOR_4B - check fuel injector no.8
INJECTOR_4B_COMMON - circuit for short circuit
to power
Fuel injector no.8 circuit short circuit
to power

P02EE- Cylinder 1 Injector Circuit NOTE: Refer to the electrical


01 Range/Performance - circuit diagrams and
General electrical failure - Circuit INJECTOR_1A - check cylinder 1
INJECTOR_1A_COMMON - injector circuit for short
circuit to power, short
Cylinder 1 injector low circuit short circuit together
circuit to power Check and install a new
Cylinder 1 injector low circuit shorted cylinder 1 injector as
to high circuit required. Refer to the
Cylinder 1 injector failure warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P02EE- Cylinder 1 Injector Circuit NOTE: Using the manufacturer


1C Range/Performance - approved diagnostic
Circuit voltage out of range - Circuit INJECTOR_1A - system, check engine
INJECTOR_1A_COMMON - control module, for
related DTCs and refer
Engine control module failure to the relevant DTC
index

P02EF- Cylinder 2 Injector Circuit NOTE: Refer to the electrical


01 Range/Performance - circuit diagrams and
General electrical failure - Circuit INJECTOR_1B - check cylinder 2
INJECTOR_1B_COMMON - injector circuit for short
circuit to power, short
Cylinder 2 injector low circuit short circuit together
circuit to power Check and install a new
Cylinder 2 injector low circuit shorted cylinder 2 injector as
to high circuit required. Refer to the
Cylinder 2 injector failure warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P02EF- Cylinder 2 Injector Circuit NOTE: Using the manufacturer


1C Range/Performance - approved diagnostic
Circuit voltage out of range - Circuit INJECTOR_1B - system, check engine
INJECTOR_1B_COMMON - control module, for
related DTCs and refer
Engine control module failure to the relevant DTC
index

P02F0- Cylinder 3 Injector Circuit NOTE: Refer to the electrical


01 Range/Performance - circuit diagrams and
General electrical failure - Circuit INJECTOR_2A - check cylinder 3
INJECTOR_2A_COMMON - injector circuit for short
circuit to power, short
Cylinder 3 injector low circuit short circuit together
circuit to power Check and install a new
Cylinder 3 injector low circuit shorted cylinder 3 injector as
to high circuit required. Refer to the
Cylinder 3 injector failure warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P02F0- Cylinder 3 Injector Circuit NOTE: Using the manufacturer


1C Range/Performance - approved diagnostic
Circuit voltage out of range - Circuit INJECTOR_2A - system, check engine
INJECTOR_2A_COMMON - control module, for
related DTCs and refer
Engine control module failure to the relevant DTC
index

P02F1- Cylinder 4 Injector Circuit NOTE: Refer to the electrical


01 Range/Performance - circuit diagrams and
General electrical failure - Circuit INJECTOR_2B - check cylinder 4
INJECTOR_2B_COMMON - injector circuit for short
circuit to power, short
Cylinder 4 injector low circuit short circuit together
circuit to power Check and install a new
Cylinder 4 injector low circuit shorted cylinder 4 injector as
to high circuit required. Refer to the
Cylinder 4 injector failure
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P02F1- Cylinder 4 Injector Circuit NOTE: Using the manufacturer


1C Range/Performance - approved diagnostic
Circuit voltage out of range - Circuit INJECTOR_2B - system, check engine
INJECTOR_2B_COMMON - control module, for
related DTCs and refer
Engine control module failure to the relevant DTC
index

P02F2- Cylinder 5 Injector Circuit NOTE: Refer to the electrical


01 Range/Performance - circuit diagrams and
General electrical failure - Circuit INJECTOR_3A - check cylinder 5
INJECTOR_3A_COMMON - injector circuit for short
circuit to power, short
Cylinder 5 injector low circuit short circuit together
circuit to power Check and install a new
Cylinder 5 injector low circuit shorted cylinder 5 injector as
to high circuit required. Refer to the
Cylinder 5 injector failure warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P02F2- Cylinder 5 Injector Circuit NOTE: Using the manufacturer


1C Range/Performance - approved diagnostic
Circuit voltage out of range - Circuit INJECTOR_3A - system, check engine
INJECTOR_3A_COMMON - control module, for
related DTCs and refer
Engine control module failure to the relevant DTC
index

P02F3- Cylinder 6 Injector Circuit NOTE: Refer to the electrical


01 Range/Performance - circuit diagrams and
General electrical failure - Circuit INJECTOR_3B - check cylinder 6
INJECTOR_3B_COMMON - injector circuit for short
circuit to power, short
Cylinder 6 injector low circuit short circuit together
circuit to power Check and install a new
Cylinder 6 injector low circuit shorted cylinder 6 injector as
to high circuit required. Refer to the
Cylinder 6 injector failure warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P02F3- Cylinder 6 Injector Circuit NOTE: Using the manufacturer


1C Range/Performance - approved diagnostic
Circuit voltage out of range - Circuit INJECTOR_3B - system, check engine
INJECTOR_3B_COMMON - control module, for
related DTCs and refer
Engine control module failure to the relevant DTC
index

P02F4- Cylinder 7 Injector Circuit NOTE: Refer to the electrical


01 Range/Performance - circuit diagrams and
General electrical failure - Circuit INJECTOR_4A - check cylinder 7
INJECTOR_4A_COMMON - injector circuit for short
circuit to power, short
Cylinder 7 injector low circuit short circuit together
circuit to power Check and install a new
Cylinder 7 injector low circuit shorted cylinder 7 injector as
to high circuit required. Refer to the
Cylinder 7 injector failure warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P02F4- Cylinder 7 Injector Circuit NOTE: Using the manufacturer


1C Range/Performance - approved diagnostic
Circuit voltage out of range - Circuit INJECTOR_4A - system, check engine
INJECTOR_4A_COMMON - control module, for
related DTCs and refer
Engine control module failure to the relevant DTC
index

P02F5- Cylinder 8 Injector Circuit NOTE: Refer to the electrical


01 Range/Performance - circuit diagrams and
General electrical failure - Circuit INJECTOR_4B - check cylinder 8
INJECTOR_4B_COMMON - injector circuit for short
circuit to power, short
Cylinder 8 injector low circuit short circuit together
circuit to power Check and install a new
Cylinder 8 injector low circuit shorted cylinder 8 injector as
to high circuit required. Refer to the
Cylinder 8 injector failure warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P02F5- Cylinder 8 Injector Circuit NOTE: Using the manufacturer


1C Range/Performance - approved diagnostic
Circuit voltage out of range - Circuit INJECTOR_4B - system, check engine
INJECTOR_4B_COMMON - control module, for
related DTCs and refer
Engine control module failure to the relevant DTC
index

P0300- Random Misfire Detected - NOTE: Check engine control


00 No sub type information module for related
Monitor description. Misfire detection fuelling, ignition coil,
injector or individual
Poor fuel supply cylinder misfire DTCs
Poor fuel quality and refer to this DTC
Fuel air ratio excessively too lean or index. Rectify these
too rich first
Catalyst/exhaust system blockage If this DTC is raised
Spark plug(s) fouled or failed with P0301-00, P0302-
Low Cylinder compression 00, P0303-00, P0304-
Reluctor ring 00, P0305-00,P0306-
Crankshaft position sensor failure 00,P0307-00, or P0308-
Camshaft position sensor failure 00, then the fuel
Injector or ignition coil connector is delivery system and air
disconnected, connector pin is backed intake system should be
out, connector pin corrosion checked and rectified
Connector is disconnected, connector first
pin is backed out, connector pin Using the manufacturer
corrosion approved diagnostic
Injector circuit short circuit to ground, system clear all stored
short circuit to power, open circuit DTCs using the
Injector(s) failure ‘Diagnosis Menu’ tab
and retest
Check the fuel system
for blockages or
restrictions, repair as
required
Check for air leaks
within the air intake
system, repair as
required
Check the
catalyst/exhaust system
for blockage, repair as
required
Check and install a new
spark plug(s) as
required
Carry out cylinder
compression checks as
required
Inspect reluctor ring for
damage
Check and install a new
crankshaft position
sensor as required
Check and install a new
camshaft position
sensor as required
Inspect connectors for
signs of water ingress,
and pins for damage
and/or corrosion
Refer to the electrical
circuit diagrams and
check injector(s) circuit
for short circuit to
ground, short circuit to
power, open circuit
Identify the misfiring
cylinder. Check and
install a new injector as
required

P0301- Cylinder 1 Misfire NOTE: Check engine control


00 Detected - No sub type module for related
information Monitor description. Misfire detection fuelling, ignition coil,
injector or individual
Poor fuel supply cylinder misfire DTCs
Poor fuel quality and refer to this DTC
Fuel air ratio excessively too lean or index. Rectify these
too rich first
Catalyst/exhaust system blockage If this DTC is raised
Spark plug(s) fouled or failed with P0300-00, then the
Low Cylinder compression fuel delivery system and
Reluctor ring air intake system should
Crankshaft position sensor failure be checked and rectified
Camshaft position sensor failure first
Injector or ignition coil connector is Using the manufacturer
disconnected, connector pin is backed approved diagnostic
out, connector pin corrosion system clear all stored
Connector is disconnected, connector DTCs using the
pin is backed out, connector pin ‘Diagnosis Menu’ tab
corrosion and retest
Injector circuit short circuit to ground, Check the fuel system
short circuit to power, open circuit for blockages or
Injector(s) failure restrictions, repair as
required
Check for air leaks
within the air intake
system, repair as
required
Check the
catalyst/exhaust system
for blockage, repair as
required
Check and install a new
spark plug(s) as
required
Carry out cylinder
compression checks as
required
Inspect reluctor ring for
damage
Check and install a new
crankshaft position
sensor as required
Check and install a new
camshaft position
sensor as required
Inspect connectors for
signs of water ingress,
and pins for damage
and/or corrosion
Refer to the electrical
circuit diagrams and
check injector(s) circuit
for short circuit to
ground, short circuit to
power, open circuit
Identify the misfiring
cylinder. Check and
install a new injector as
required

P0302- Cylinder 2 Misfire NOTE: Check engine control


00 Detected - No sub type module for related
information Monitor description. Misfire detection fuelling, ignition coil,
injector or individual
Poor fuel supply cylinder misfire DTCs
Poor fuel quality and refer to this DTC
Fuel air ratio excessively too lean or index. Rectify these
too rich first
Catalyst/exhaust system blockage If this DTC is raised
Spark plug(s) fouled or failed with P0300-00, then the
Low Cylinder compression fuel delivery system and
Reluctor ring air intake system should
Crankshaft position sensor failure be checked and rectified
Camshaft position sensor failure first
Injector or ignition coil connector is Using the manufacturer
disconnected, connector pin is backed approved diagnostic
out, connector pin corrosion system clear all stored
Connector is disconnected, connector DTCs using the
pin is backed out, connector pin ‘Diagnosis Menu’ tab
corrosion and retest
Injector circuit short circuit to ground, Check the fuel system
short circuit to power, open circuit for blockages or
Injector(s) failure restrictions, repair as
required
Check for air leaks
within the air intake
system, repair as
required
Check the
catalyst/exhaust system
for blockage, repair as
required
Check and install a new
spark plug(s) as
required
Carry out cylinder
compression checks as
required
Inspect reluctor ring for
damage
Check and install a new
crankshaft position
sensor as required
Check and install a new
camshaft position
sensor as required
Inspect connectors for
signs of water ingress,
and pins for damage
and/or corrosion
Refer to the electrical
circuit diagrams and
check injector(s) circuit
for short circuit to
ground, short circuit to
power, open circuit
Identify the misfiring
cylinder. Check and
install a new injector as
required

P0303- Cylinder 3 Misfire NOTE: Check engine control


00 Detected - No sub type module for related
information Monitor description. Misfire detection fuelling, ignition coil,
injector or individual
Poor fuel supply cylinder misfire DTCs
Poor fuel quality and refer to this DTC
Fuel air ratio excessively too lean or index. Rectify these
too rich first
Catalyst/exhaust system blockage If this DTC is raised
Spark plug(s) fouled or failed with P0300-00, then the
Low Cylinder compression fuel delivery system and
Reluctor ring air intake system should
Crankshaft position sensor failure be checked and rectified
Camshaft position sensor failure first
Injector or ignition coil connector is Using the manufacturer
disconnected, connector pin is backed approved diagnostic
out, connector pin corrosion system clear all stored
Connector is disconnected, connector DTCs using the
pin is backed out, connector pin ‘Diagnosis Menu’ tab
corrosion and retest
Injector circuit short circuit to ground, Check the fuel system
short circuit to power, open circuit for blockages or
Injector(s) failure restrictions, repair as
required
Check for air leaks
within the air intake
system, repair as
required
Check the
catalyst/exhaust system
for blockage, repair as
required
Check and install a new
spark plug(s) as
required
Carry out cylinder
compression checks as
required
Inspect reluctor ring for
damage
Check and install a new
crankshaft position
sensor as required
Check and install a new
camshaft position
sensor as required
Inspect connectors for
signs of water ingress,
and pins for damage
and/or corrosion
Refer to the electrical
circuit diagrams and
check injector(s) circuit
for short circuit to
ground, short circuit to
power, open circuit
Identify the misfiring
cylinder. Check and
install a new injector as
required

P0304- Cylinder 4 Misfire NOTE: Check engine control


00 Detected - No sub type module for related
information Monitor description. Misfire detection fuelling, ignition coil,
injector or individual
Poor fuel supply cylinder misfire DTCs
Poor fuel quality and refer to this DTC
Fuel air ratio excessively too lean or index. Rectify these
too rich first
Catalyst/exhaust system blockage If this DTC is raised
Spark plug(s) fouled or failed with P0300-00, then the
Low Cylinder compression fuel delivery system and
Reluctor ring air intake system should
Crankshaft position sensor failure be checked and rectified
Camshaft position sensor failure first
Injector or ignition coil connector is Using the manufacturer
disconnected, connector pin is backed approved diagnostic
out, connector pin corrosion system clear all stored
Connector is disconnected, connector DTCs using the
pin is backed out, connector pin ‘Diagnosis Menu’ tab
corrosion and retest
Injector circuit short circuit to ground, Check the fuel system
short circuit to power, open circuit for blockages or
Injector(s) failure restrictions, repair as
required
Check for air leaks
within the air intake
system, repair as
required
Check the
catalyst/exhaust system
for blockage, repair as
required
Check and install a new
spark plug(s) as
required
Carry out cylinder
compression checks as
required
Inspect reluctor ring for
damage
Check and install a new
crankshaft position
sensor as required
Check and install a new
camshaft position
sensor as required
Inspect connectors for
signs of water ingress,
and pins for damage
and/or corrosion
Refer to the electrical
circuit diagrams and
check injector(s) circuit
for short circuit to
ground, short circuit to
power, open circuit
Identify the misfiring
cylinder. Check and
install a new injector as
required

P0305- Cylinder 5 Misfire NOTE: Check engine control


00 Detected - No sub type module for related
information Monitor description. Misfire detection fuelling, ignition coil,
injector or individual
Poor fuel supply cylinder misfire DTCs
Poor fuel quality and refer to this DTC
Fuel air ratio excessively too lean or index. Rectify these
too rich first
Catalyst/exhaust system blockage If this DTC is raised
Spark plug(s) fouled or failed with P0300-00, then the
Low Cylinder compression fuel delivery system and
Reluctor ring air intake system should
Crankshaft position sensor failure be checked and rectified
Camshaft position sensor failure first
Injector or ignition coil connector is Using the manufacturer
disconnected, connector pin is backed approved diagnostic
out, connector pin corrosion system clear all stored
Connector is disconnected, connector DTCs using the
pin is backed out, connector pin ‘Diagnosis Menu’ tab
corrosion and retest
Injector circuit short circuit to ground, Check the fuel system
short circuit to power, open circuit for blockages or
Injector(s) failure restrictions, repair as
required
Check for air leaks
within the air intake
system, repair as
required
Check the
catalyst/exhaust system
for blockage, repair as
required
Check and install a new
spark plug(s) as
required
Carry out cylinder
compression checks as
required
Inspect reluctor ring for
damage
Check and install a new
crankshaft position
sensor as required
Check and install a new
camshaft position
sensor as required
Inspect connectors for
signs of water ingress,
and pins for damage
and/or corrosion
Refer to the electrical
circuit diagrams and
check injector(s) circuit
for short circuit to
ground, short circuit to
power, open circuit
Identify the misfiring
cylinder. Check and
install a new injector as
required

P0306- Cylinder 6 Misfire NOTE: Check engine control


00 Detected - No sub type module for related
information Monitor description. Misfire detection fuelling, ignition coil,
injector or individual
Poor fuel supply cylinder misfire DTCs
Poor fuel quality and refer to this DTC
Fuel air ratio excessively too lean or index. Rectify these
too rich first
Catalyst/exhaust system blockage If this DTC is raised
Spark plug(s) fouled or failed with P0300-00, then the
Low Cylinder compression fuel delivery system and
Reluctor ring air intake system should
Crankshaft position sensor failure be checked and rectified
Camshaft position sensor failure first
Injector or ignition coil connector is Using the manufacturer
disconnected, connector pin is backed approved diagnostic
out, connector pin corrosion system clear all stored
Connector is disconnected, connector DTCs using the
pin is backed out, connector pin ‘Diagnosis Menu’ tab
corrosion and retest
Injector circuit short circuit to ground, Check the fuel system
short circuit to power, open circuit for blockages or
Injector(s) failure restrictions, repair as
required
Check for air leaks
within the air intake
system, repair as
required
Check the
catalyst/exhaust system
for blockage, repair as
required
Check and install a new
spark plug(s) as
required
Carry out cylinder
compression checks as
required
Inspect reluctor ring for
damage
Check and install a new
crankshaft position
sensor as required
Check and install a new
camshaft position
sensor as required
Inspect connectors for
signs of water ingress,
and pins for damage
and/or corrosion
Refer to the electrical
circuit diagrams and
check injector(s) circuit
for short circuit to
ground, short circuit to
power, open circuit
Identify the misfiring
cylinder. Check and
install a new injector as
required

P0307- Cylinder 7 Misfire NOTE: Check engine control


00 Detected - No sub type module for related
information Monitor description. Misfire detection fuelling, ignition coil,
injector or individual
Poor fuel supply cylinder misfire DTCs
Poor fuel quality and refer to this DTC
Fuel air ratio excessively too lean or index. Rectify these
too rich first
Catalyst/exhaust system blockage If this DTC is raised
Spark plug(s) fouled or failed with P0300-00, then the
Low Cylinder compression fuel delivery system and
Reluctor ring air intake system should
Crankshaft position sensor failure be checked and rectified
Camshaft position sensor failure first
Injector or ignition coil connector is Using the manufacturer
disconnected, connector pin is backed approved diagnostic
out, connector pin corrosion system clear all stored
Connector is disconnected, connector DTCs using the
pin is backed out, connector pin ‘Diagnosis Menu’ tab
corrosion and retest
Injector circuit short circuit to ground, Check the fuel system
short circuit to power, open circuit for blockages or
Injector(s) failure restrictions, repair as
required
Check for air leaks
within the air intake
system, repair as
required
Check the
catalyst/exhaust system
for blockage, repair as
required
Check and install a new
spark plug(s) as
required
Carry out cylinder
compression checks as
required
Inspect reluctor ring for
damage
Check and install a new
crankshaft position
sensor as required
Check and install a new
camshaft position
sensor as required
Inspect connectors for
signs of water ingress,
and pins for damage
and/or corrosion
Refer to the electrical
circuit diagrams and
check injector(s) circuit
for short circuit to
ground, short circuit to
power, open circuit
Identify the misfiring
cylinder. Check and
install a new injector as
required

P0308- Cylinder 8 Misfire NOTE: Check engine control


00 Detected - No sub type module for related
information Monitor description. Misfire detection fuelling, ignition coil,
injector or individual
Poor fuel supply cylinder misfire DTCs
Poor fuel quality and refer to this DTC
Fuel air ratio excessively too lean or index. Rectify these
too rich first
Catalyst/exhaust system blockage If this DTC is raised
Spark plug(s) fouled or failed with P0300-00, then the
Low Cylinder compression fuel delivery system and
Reluctor ring air intake system should
Crankshaft position sensor failure be checked and rectified
Camshaft position sensor failure first
Injector or ignition coil connector is Using the manufacturer
disconnected, connector pin is backed approved diagnostic
out, connector pin corrosion system clear all stored
Connector is disconnected, connector DTCs using the
pin is backed out, connector pin ‘Diagnosis Menu’ tab
corrosion and retest
Injector circuit short circuit to ground, Check the fuel system
short circuit to power, open circuit for blockages or
Injector(s) failure restrictions, repair as
required
Check for air leaks
within the air intake
system, repair as
required
Check the
catalyst/exhaust system
for blockage, repair as
required
Check and install a new
spark plug(s) as
required
Carry out cylinder
compression checks as
required
Inspect reluctor ring for
damage
Check and install a new
crankshaft position
sensor as required
Check and install a new
camshaft position
sensor as required
Inspect connectors for
signs of water ingress,
and pins for damage
and/or corrosion
Refer to the electrical
circuit diagrams and
check injector(s) circuit
for short circuit to
ground, short circuit to
power, open circuit
Identify the misfiring
cylinder. Check and
install a new injector as
required

P0313- Misfire Detected With Poor fuel quality Using the manufacturer
00 Low Fuel - No sub type Catalyst/exhaust system blockage approved diagnostic
information Spark plug(s) fouled or failed system, check engine
Coil(s) failure control module, for
Injector(s) circuit short circuit to related DTCs and refer
ground, short circuit to power, open to the relevant DTC
circuit index
Injector(s) failure Check the fuel system
Fuel system excessively too lean or too for blockages, repair as
rich required
Camshaft position sensor failure Check the
catalyst/exhaust system
for blockage, repair as
required
Check and install a new
spark plug(s) as
required
Check and install a new
coil(s) as required
Refer to the electrical
circuit diagrams and
check injector(s) circuit
for short circuit to
ground, short circuit to
power, open circuit
Check and install a new
injector(s) as required
Check for air leaks
within the intake system
Check and install a new
camshaft position
sensor as required
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0316- Misfire Detected On Poor fuel quality Using the manufacturer


00 Startup (First 1000 Catalyst/exhaust system blockage approved diagnostic
Revolutions) - No sub type Spark plug(s) fouled or failed system, check engine
information Coil(s) failure control module, for
Injector(s) circuit short circuit to related DTCs and refer
ground, short circuit to power, open to the relevant DTC
circuit index
Injector(s) failure Check the fuel system
Fuel system excessively too lean or too for blockages, repair as
rich required
Camshaft position sensor failure Check the
catalyst/exhaust system
for blockage, repair as
required
Check and install a new
spark plug(s) as
required
Check and install a new
coil(s) as required
Refer to the electrical
circuit diagrams and
check injector(s) circuit
for short circuit to
ground, short circuit to
power, open circuit
Check and install a new
injector(s) as required
Check for air leaks
within the intake system
Check and install a new
camshaft position
sensor as required
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0327- Knock Sensor 1 Circuit NOTE: Ensure a good electrical


00 Low (Bank1) - No sub type contact with the
information - Circuit KNOCK_SENSOR_1A_POS - cylinder block
Refer to the electrical
Poor sensor contact with the cylinder circuit diagrams and
block check knock sensor
Knock sensor bank 1 front circuit short bank 1 front circuit for
circuit to ground, open circuit short circuit to ground,
Knock sensor bank 1 front failure open circuit
Check and install a new
knock sensor bank 1
front as required. Refer
to the warranty policy
and procedures manual,
or determine if any
prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0328- Knock Sensor 1 Circuit NOTE: Ensure a good electrical


00 High (Bank 1) - No sub contact with the
type information - Circuit KNOCK_SENSOR_1A_POS - cylinder block
Refer to the electrical
Poor sensor contact with the cylinder circuit diagrams and
block check knock sensor
Knock sensor bank 1 front circuit high bank 1 front circuit for
resistance, short circuit to power short circuit to power,
Knock sensor bank 1 front failure high resistance
Check and install a new
knock sensor bank 1
front as required. Refer
to the warranty policy
and procedures manual,
or determine if any
prior approval
programme is in
operation, prior to the
installation of a new
module/component

P032C- Knock Sensor 3 Circuit NOTE: Ensure a good electrical


00 Low (Bank1) - No sub type contact with the
information - Circuit KNOCK_SENSOR_2A_POS - cylinder block
Refer to the electrical
Poor sensor contact with the cylinder circuit diagrams and
block check knock sensor
Knock sensor bank 2 front circuit short bank 2 front circuit for
circuit to ground short circuit to ground
Knock sensor bank 2 front failure Check and install a new
knock sensor bank 2
front as required. Refer
to the warranty policy
and procedures manual,
or determine if any
prior approval
programme is in
operation, prior to the
installation of a new
module/component

P032D- Knock Sensor 3 Circuit NOTE: Ensure a good electrical


00 High (Bank1) - No sub contact with the
type information - Circuit KNOCK_SENSOR_2A_POS - cylinder block
Refer to the electrical
Poor sensor contact with the cylinder circuit diagrams and
block check knock sensor
Knock sensor bank 2 front circuit high bank 2 front circuit for
resistance, short circuit to power short circuit to power,
Knock sensor bank 2 front failure high resistance
Check and install a new
knock sensor bank 2
front as required. Refer
to the warranty policy
and procedures manual,
or determine if any
prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0332- Knock Sensor 2 Circuit NOTE: Ensure a good electrical


00 Low (Bank2) - No sub type contact with the
information - Circuit KNOCK_SENSOR_1B_POS - cylinder block
Refer to the electrical
Poor sensor contact with the cylinder circuit diagrams and
block check knock sensor
Knock sensor bank 1 rear circuit short bank 1 rear circuit for
circuit to ground, open circuit short circuit to ground,
Knock sensor bank 1 rear failure open circuit
Check and install a new
knock sensor bank 1
rear as required. Refer
to the warranty policy
and procedures manual,
or determine if any
prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0333- Knock Sensor 2 Circuit NOTE: Ensure a good electrical


00 High (Bank 2) - No sub contact with the
type information - Circuit KNOCK_SENSOR_1B_POS - cylinder block
Refer to the electrical
Poor sensor contact with the cylinder circuit diagrams and
block check knock sensor
Knock sensor bank 1 rear circuit short bank 1 rear circuit for
circuit to power short circuit to power
Knock sensor bank 1 rear failure Check and install a new
knock sensor bank 1
rear as required. Refer
to the warranty policy
and procedures manual,
or determine if any
prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0335- Crankshaft Position Sensor NOTE: Refer to the electrical


02 A Circuit - General signal circuit diagrams and
failure - Circuit CRANK_SENSOR - check crankshaft
position sensor circuit
Crankshaft position sensor circuit short for short circuit to
circuit to ground, short circuit to ground, short circuit to
power, high resistance, disconnected power, high resistance,
Crankshaft position sensor failure disconnected
Check and install new
crankshaft position as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0335- Crankshaft Position Sensor NOTE: Refer to the electrical


31 A Circuit - No signal circuit diagrams and
- Circuit CRANK_SENSOR - check crankshaft
position sensor circuit
Crankshaft position sensor circuit - for short circuit to
short circuit to ground, short circuit to ground, short circuit to
power, high resistance, disconnected power, high resistance,
Crankshaft position sensor failure disconnected
Check and install new
crankshaft position as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0336- Crankshaft Position Sensor NOTE: Refer to the electrical


00 A Circuit circuit diagrams and
Range/Performance - No - Circuit CRANK_SENSOR - check crankshaft
sub type information position sensor circuit
Crankshaft position sensor circuit short for short circuit to
circuit to ground, short circuit to ground, short circuit to
power, high resistance, disconnected power, high resistance,
Crankshaft position sensor gap disconnected
incorrect, foreign matter on sensor Check crankshaft
face, damaged teeth on rotor position sensor for
Crankshaft position sensor failure damage and check air
gap (check at 90B0
intervals, should be no
greater than 4.5mm)
Check and install new
crankshaft position as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P033C- Knock Sensor 4 Circuit NOTE: Ensure a good electrical


00 Low (Bank 2) - No sub contact with the
type information - Circuit KNOCK_SENSOR_2B_POS - cylinder block
Refer to the electrical
Poor sensor contact with the cylinder circuit diagrams and
block check knock sensor
Knock sensor bank 2 rear circuit short bank 2 rear circuit for
circuit to ground short circuit to ground
Knock sensor bank 2 rear failure Check and install a new
knock sensor bank 2
rear as required. Refer
to the warranty policy
and procedures manual,
or determine if any
prior approval
programme is in
operation, prior to the
installation of a new
module/component

P033D- Knock Sensor 4 Circuit NOTE: Ensure a good electrical


00 High (Bank 2) - No sub contact with the
type information - Circuit KNOCK_SENSOR_2B_POS - cylinder block
Refer to the electrical
Poor sensor contact with the cylinder circuit diagrams and
block check knock sensor
Knock sensor bank 2 rear circuit high bank 2 rear circuit for
resistance, short circuit to power short circuit to power,
Knock sensor bank 2 rear failure high resistance
Check and install a new
knock sensor bank 2
rear as required. Refer
to the warranty policy
and procedures manual,
or determine if any
prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0340- Camshaft Position Sensor NOTE: Refer to the electrical


02 A Circuit (Bank 1 or single circuit diagrams and
sensor) - General signal - Circuit CAM_IN_SENSOR_A - check camshaft position
failure sensor bank 1 inlet
Camshaft position sensor bank 1 inlet sensor circuit for short
sensor circuit short circuit to ground, circuit to ground, short
short circuit to power, high resistance, circuit to power, high
disconnected resistance, disconnected
Camshaft position sensor bank 1 inlet Check camshaft
sensor gap incorrect, foreign matter on position sensor bank 1
sensor face, damaged rotor inlet sensor for correct
Camshaft position sensor bank 1 inlet installation and damage
sensor failure Check and install a new
camshaft position
sensor bank 1 inlet as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0340- Camshaft Position Sensor NOTE: Refer to the electrical


31 A Circuit (Bank 1 or single circuit diagrams and
sensor) - No signal - Circuit CAM_IN_SENSOR_A - check camshaft position
sensor bank 1 inlet
Camshaft position sensor bank 1 inlet sensor circuit for short
sensor circuit short circuit to ground, circuit to ground, short
short circuit to power, high resistance, circuit to power, high
disconnected resistance, disconnected
Camshaft position sensor bank 1 inlet Check camshaft
sensor gap incorrect, foreign matter on position sensor bank 1
sensor face, damaged rotor inlet sensor for correct
Camshaft position sensor bank 1 inlet installation and damage
sensor failure Check and install a new
camshaft position
sensor bank 1 inlet as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0341- Camshaft Position Sensor NOTE: Refer to the electrical


00 A Circuit circuit diagrams and
Range/Performance (Bank - Circuit CAM_IN_SENSOR_A - check camshaft position
1 or single sensor) - No sub sensor bank 1 inlet
type information Camshaft position sensor bank 1 inlet sensor circuit for short
sensor circuit short circuit to ground, circuit to ground, short
short circuit to power, high resistance, circuit to power, high
disconnected resistance, disconnected
Camshaft position sensor bank 1 inlet Check camshaft
sensor gap incorrect, foreign matter on position sensor bank 1
sensor face, damaged rotor inlet sensor for correct
Camshaft position sensor bank 1 inlet installation and damage
sensor failure Check and install a new
camshaft position
sensor bank 1 inlet as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0345- Camshaft Position Sensor NOTE: Refer to the electrical


02 A Circuit (Bank 2) - circuit diagrams and
General signal failure - Circuit CAM_IN_SENSOR_B - check camshaft position
sensor bank 2 inlet
Camshaft position sensor bank 2 inlet sensor circuit for short
sensor circuit short circuit to ground, circuit to ground, short
short circuit to power, high resistance, circuit to power, high
disconnected resistance, disconnected
Camshaft position sensor bank 2 inlet Check camshaft
sensor gap incorrect, foreign matter on position sensor bank 2
sensor face, damaged rotor inlet sensor for correct
Camshaft position sensor bank 2 inlet installation and damage
sensor failure Check and install a new
camshaft position
sensor bank 2 inlet as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0345- Camshaft Position Sensor NOTE: Refer to the electrical


31 A Circuit (Bank 2) - No circuit diagrams and
signal - Circuit CAM_IN_SENSOR_B - check camshaft position
sensor bank 2 inlet
Camshaft position sensor bank 2 inlet sensor circuit for short
sensor circuit - short circuit to ground, circuit to ground, short
short circuit to power, high resistance, circuit to power, high
disconnected resistance, disconnected
Camshaft position sensor bank 2 inlet Check camshaft
sensor gap incorrect, foreign matter on position sensor bank 2
sensor face, damaged rotor inlet sensor for correct
Camshaft position sensor bank 2 inlet installation and damage
sensor failure Check and install a new
camshaft position
sensor bank 2 inlet as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0346- Camshaft Position Sensor NOTE: Refer to the electrical


00 A Circuit circuit diagrams and
Range/Performance (Bank - Circuit CAM_IN_SENSOR_B - check camshaft position
2) - No sub type sensor bank 2 inlet
information Camshaft position sensor bank 2 inlet sensor circuit for short
sensor circuit - short circuit to ground, circuit to ground, short
short circuit to power, high resistance, circuit to power, high
disconnected resistance, disconnected
Camshaft position sensor bank 2 inlet Check camshaft
sensor gap incorrect, foreign matter on position sensor bank 2
sensor face, target rotor run-out inlet sensor for correct
Camshaft position sensor bank 2 inlet installation and damage
sensor failure Check target rotor for
run out, repair as
required
Check and install a new
camshaft position
sensor bank 2 inlet as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0351- Ignition Coil A NOTE: Refer to the electrical


13 Primary/Secondary Circuit circuit diagrams and
- Circuit open - Circuit IGNITION_1A - check ignition coil 1
circuit for open circuit,
Ignition coil 1 open circuit disconnected ignition
Ignition coil 1 disconnected coil, high resistance
Ignition coil high resistance

P0352- Ignition Coil B NOTE: Refer to the electrical


13 Primary/Secondary Circuit circuit diagrams and
- Circuit open - Circuit IGNITION_1B - check ignition coil 2
circuit for open circuit,
Ignition coil 2 open circuit disconnected ignition
Ignition coil 2 disconnected coil, high resistance
Ignition coil high resistance

P0353- Ignition Coil C NOTE: Refer to the electrical


13 Primary/Secondary Circuit circuit diagrams and
- Circuit open - Circuit IGNITION_2A - check ignition coil 3
circuit for open circuit,
Ignition coil 3 open circuit disconnected ignition
Ignition coil 3 disconnected coil, high resistance
Ignition coil high resistance

P0354- Ignition Coil D NOTE: Refer to the electrical


13 Primary/Secondary Circuit circuit diagrams and
- Circuit open - Circuit IGNITION_2B - check ignition coil 4
circuit for open circuit,
Ignition coil 4 open circuit disconnected ignition
Ignition coil 4 disconnected coil, high resistance
Ignition coil high resistance

P0355- Ignition Coil E NOTE: Refer to the electrical


13 Primary/Secondary Circuit circuit diagrams and
- Circuit open - Circuit IGNITION_3A - check ignition coil 5
circuit for open circuit,
Ignition coil 5 open circuit disconnected ignition
Ignition coil 5 disconnected coil, high resistance
Ignition coil high resistance

P0356- Ignition Coil F NOTE: Refer to the electrical


13 Primary/Secondary Circuit circuit diagrams and
- Circuit open - Circuit IGNITION_3B - check ignition coil 6
circuit for open circuit,
Ignition coil 6 open circuit disconnected ignition
Ignition coil 6 disconnected coil, high resistance
Ignition coil high resistance

P0357- Ignition Coil G NOTE: Refer to the electrical


13 Primary/Secondary Circuit circuit diagrams and
- Circuit open - Circuit IGNITION_4A - check ignition coil 7
circuit for open circuit,
Ignition coil 7 open circuit disconnected ignition
Ignition coil 7 disconnected coil, high resistance
Ignition coil high resistance

P0358- Ignition Coil H NOTE: Refer to the electrical


13 Primary/Secondary Circuit circuit diagrams and
- Circuit open - Circuit IGNITION_4B - check ignition coil 8
circuit for open circuit,
Ignition coil 8 open circuit disconnected ignition
Ignition coil 8 disconnected coil, high resistance
Ignition coil high resistance

P0365- Camshaft Position Sensor NOTE: Refer to the electrical


02 B Circuit (Bank 1) - circuit diagrams and
General signal failure - Circuit CAM_EX_SENSOR_A - check camshaft position
sensor bank 1 outlet
Camshaft position sensor bank 1 outlet sensor circuit for short
sensor circuit short circuit to ground, circuit to ground, short
short circuit to power, high resistance, circuit to power, high
disconnected resistance, disconnected
Camshaft position sensor bank 1 outlet Check camshaft
sensor gap incorrect, foreign matter on position sensor bank 1
sensor face, damaged rotor outlet sensor for correct
Camshaft position sensor bank 1 outlet installation and damage
sensor failure Check and install a new
camshaft position
sensor bank 1 outlet as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0366- Camshaft Position Sensor NOTE: Refer to the electrical


00 B Circuit circuit diagrams and
Range/Performance (Bank - Circuit CAM_EX_SENSOR_A - check camshaft position
1) - No sub type sensor bank 1 outlet
information Camshaft position sensor bank 1 outlet sensor circuit for short
sensor circuit short circuit to ground, circuit to ground, short
short circuit to power, high resistance, circuit to power, high
disconnected resistance, disconnected
Camshaft position sensor bank 1 outlet Check camshaft
sensor gap incorrect, foreign matter on position sensor bank 1
sensor face, target rotor run-out outlet sensor for correct
Camshaft position sensor bank 1 outlet installation and damage
sensor failure Check target run-out,
repair as required
Check and install a new
camshaft position
sensor bank 1 outlet as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0390- Camshaft Position Sensor NOTE: Refer to the electrical


02 B Circuit (Bank 2) - circuit diagrams and
General signal failure - Circuit CAM_EX_SENSOR_B - check camshaft position
sensor bank 2 outlet
Camshaft position sensor bank 2 outlet sensor circuit for short
sensor circuit short circuit to ground, circuit to ground, short
short circuit to power, high resistance, circuit to power, high
disconnected resistance, disconnected
Camshaft position sensor bank 2 outlet Check camshaft
sensor gap incorrect, foreign matter on position sensor bank 2
sensor face, damaged rotor outlet sensor for correct
Camshaft position sensor bank 2 outlet installation and damage
sensor failure Check and install a new
camshaft position
sensor bank 2 outlet as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0391- Camshaft Position Sensor NOTE: Refer to the electrical


00 B Circuit circuit diagrams and
Range/Performance (Bank - Circuit CAM_EX_SENSOR_B - check camshaft position
2) - No sub type sensor bank 2 outlet
information Camshaft position sensor bank 2 outlet sensor circuit for short
sensor circuit short circuit to ground, circuit to ground, short
short circuit to power, high resistance, circuit to power, high
disconnected resistance, disconnected
Camshaft position sensor bank 2 outlet Check camshaft
sensor gap incorrect, foreign matter on position sensor bank 2
sensor face, damaged rotor, rotor run- outlet sensor for correct
out installation and damage
Camshaft position sensor bank 2 outlet Check target rotor,
sensor failure repair as required
Check and install a new
camshaft position
sensor bank 2 outlet as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0420- Catalyst System Efficiency Catalytic converter failure due to Using the manufacturer
00 Below Threshold (Bank 1) overheating damage caused by misfire approved diagnostic
- No sub type information and/or lean combustion system, check for
Catalytic converter failure due to misfire/lean combustion
poisoning caused by excessive oil related DTCs and refer
consumption and/or contaminated fuel to the relevant DTC
index
Check the oil and fuel
condition/level
Check the catalytic
converter for damage
Check and install a new
catalytic converter bank
1 as required. Refer to
the warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0430- Catalyst System Efficiency Catalytic converter failure due to Using the manufacturer
00 Below Threshold (Bank 2) overheating damage caused by misfire approved diagnostic
- No sub type information and/or lean combustion system, check for
Catalytic converter failure due to misfire/lean combustion
poisoning caused by excessive oil related DTCs and refer
consumption and/or contaminated fuel to the relevant DTC
index
Check the oil and fuel
condition/level
Check the catalytic
converter for damage
Check and install a new
catalytic converter bank
2 as required. Refer to
the warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0441- Evaporative Emission NOTE: Check all evaporative


00 System Incorrect Purge emission system hoses,
Flow - No sub type - Circuit PURGE_VALVE - pipes and connection
information are serviceable,
Evaporative emission system hoses, repair/replace as
pipes or connection failure required
Purge control valve circuit short circuit Refer to the electrical
to ground, short circuit to power, open circuit diagrams and
circuit, high resistance check purge control
Purge control valve failure valve circuit for short
circuit to ground, short
circuit to power, open
circuit
Check and install a new
purge control valve as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0442- Evaporative Emission Evaporative emissions system leak NOTES:


00 System Leak Detected
(small leak) - No sub type If purge valve related
information DTCs are also set,
perform the relevant
corrective action(s)
first.
It is not possible to
replicate the failure
event as certain entry
conditions must be
satisfied (for more
information, refer to
section 303-13:
Evaporative Emissions /
Description and
Operation). To verify
the customer concern,
perform routine
Evaporative System
Diagnostic Check and
re-read DTCs.

Refer to the relevant


section of the workshop
manual and check the
evaporative emissions
system for leaks. For
additional information,
refer to: Evaporative
Emissions (303-13B
Evaporative Emissions -
V8 N/A 5.0L Petrol/V8
S/C 5.0L Petrol,
Diagnosis and Testing).

P0444- Evaporative Emission Purge valve circuit open circuit, high Refer to the electrical
13 System Purge Control resistance circuit diagrams and
Valve A Circuit Open - check the purge valve
Circuit open circuit for open circuit,
high resistance

P0447- Evaporative Emission NOTES: Refer to the electrical


00 System Vent Control circuit diagrams and
Circuit Open - No sub type - Circuit COV - check diagnostic
information module tank leakage
LR - Circuit CHANGE OVER module circuit for open
VALVE - circuit
Check diagnostic
Diagnostic module tank leakage module tank leakage
module circuit open circuit module fuse and replace
Diagnostic module tank leakage as required
module circuit fuse blown / not secure Check and install a new
in holder diagnostic module tank
Diagnostic module tank leakage leakage module as
module failure required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component
P0448- Evaporative Emission NOTES: Refer to the electrical
00 System Vent Control circuit diagrams and
Circuit Shorted - No sub - Circuit COV - check diagnostic
type information module tank leakage
LR - Circuit CHANGE OVER module circuit for short
VALVE - circuit to ground, short
circuit to power, open
Diagnostic module tank leakage circuit
module circuit, short circuit to ground, Check and install a new
short circuit to power, open circuit diagnostic module tank
Diagnostic module tank leakage leakage module as
module failure required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0456- Evaporative Emission Evaporative emissions system leak NOTES:


00 System Leak Detected
(very small leak) - No sub If purge valve related
type information DTCs are also set,
perform the relevant
corrective action(s)
first.

It is not possible to
replicate the failure
event as certain entry
conditions must be
satisfied (for more
information, refer to
section 303-13:
Evaporative Emissions /
Description and
Operation). To verify
the customer concern,
perform routine
Evaporative System
Diagnostic Check and
re-read DTCs.

Refer to the relevant


section of the workshop
manual and check the
evaporative emissions
system for leaks. For
additional information,
refer to: Evaporative
Emissions (303-13B
Evaporative Emissions -
V8 N/A 5.0L Petrol/V8
S/C 5.0L Petrol,
Diagnosis and Testing).
P0458- Evaporative Emission Purge valve circuit short circuit to Refer to the electrical
11 System Purge Control ground circuit diagrams and
Valve Circuit Low - check the purge valve
Circuit short to ground circuit for short circuit
to ground

P0459- Evaporative Emission Purge valve circuit short circuit to Refer to the electrical
12 System Purge Control power circuit diagrams and
Valve Circuit High - check the purge valve
Circuit short to battery circuit for short circuit
to power

P0461- Fuel Level Sensor A Fuel level sensor circuit open circuit, Refer to the electrical
29 Circuit Range/Performance short circuit to ground, short circuit to circuit diagrams and
- Signal invalid power check fuel level sensor
Fuel level sensor stuck circuit for short circuit
Fuel level sensor failure to ground, short circuit
to power, open circuit
Check for stuck level
sensor
Check and install a new
fuel level sensor as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0461- Fuel Level Sensor A Fuel level sensor circuit short circuit to Refer to the electrical
2F Circuit Range/Performance ground, short circuit to power, open circuit diagrams and
- Signal erratic circuit check fuel level sensor
Fuel level sensor track damaged circuit for short circuit
Fuel level sensor failure to ground, short circuit
to power, open circuit
Check level sensor track
for damage
Check and install a new
fuel level sensor as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0481- Fan 2 Control Circuit - NOTE: Using the manufacturer


04 System internal failures approved diagnostic
- Circuit RAD_FAN_PWM - system check
datalogger signal,
Damaged cooling fan control unit Electric Fan PWM
Cooling fan control unit failure Control - Commanded
Duty Cycle (0x03F9)
If fault persists, refer to
the relevant section of
the workshop manual
and refer to the cooling
fan pinpoint test
procedures For
additional information,
refer to: Engine Cooling
(303-03D Engine
Cooling - V8 N/A 5.0L
Petrol/V8 S/C 5.0L
Petrol, Diagnosis and
Testing).
Check and install a new
cooling fan control unit
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0481- Fan 2 Control Circuit - NOTE: Using the manufacturer


09 Component failures approved diagnostic
- Circuit RAD_FAN_PWM - system check
datalogger signal,
Damaged cooling fan control unit Electric Fan PWM
Cooling fan control unit failure Control - Commanded
Duty Cycle (0x03F9)
If fault persists, refer to
the relevant section of
the workshop manual
and refer to the cooling
fan pinpoint test
procedures For
additional information,
refer to: Engine Cooling
(303-03D Engine
Cooling - V8 N/A 5.0L
Petrol/V8 S/C 5.0L
Petrol, Diagnosis and
Testing).
Check and install a new
cooling fan control unit
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0481- Fan 2 Control Circuit - NOTE: Using the manufacturer


11 Circuit short to ground approved diagnostic
- Circuit RAD_FAN_PWM - system check
datalogger signal,
Cooling fan control unit circuit short Electric Fan PWM
circuit to ground Control - Commanded
Duty Cycle (0x03F9)
Refer to the electrical
circuit diagrams and
check cooling fan
control unit circuit for
short circuit to ground
If fault persists, refer to
the relevant section of
the workshop manual
and refer to the cooling
fan pinpoint test
procedures For
additional information,
refer to: Engine Cooling
(303-03D Engine
Cooling - V8 N/A 5.0L
Petrol/V8 S/C 5.0L
Petrol, Diagnosis and
Testing).

P0481- Fan 2 Control Circuit - NOTE: Using the manufacturer


12 Circuit short to battery approved diagnostic
- Circuit RAD_FAN_PWM - system check
datalogger signal,
Cooling fan control unit circuit short Electric Fan PWM
circuit to power Control - Commanded
Duty Cycle (0x03F9)
Refer to the electrical
circuit diagrams and
check cooling fan
control unit circuit for
short circuit to power
If fault persists, refer to
the relevant section of
the workshop manual
and refer to the cooling
fan pinpoint test
procedures For
additional information,
refer to: Engine Cooling
(303-03D Engine
Cooling - V8 N/A 5.0L
Petrol/V8 S/C 5.0L
Petrol, Diagnosis and
Testing).

P0481- Fan 2 Control Circuit - NOTE: Using the manufacturer


13 Circuit open approved diagnostic
- Circuit RAD_FAN_PWM - system check
datalogger signal,
Cooling fan control unit circuit open Electric Fan PWM
circuit Control - Commanded
Duty Cycle (0x03F9)
Refer to the electrical
circuit diagrams and
check cooling fan
control unit circuit for
open circuit
If fault persists, refer to
the relevant section of
the workshop manual
and refer to the cooling
fan pinpoint test
procedures For
additional information,
refer to: Engine Cooling
(303-03D Engine
Cooling - V8 N/A 5.0L
Petrol/V8 S/C 5.0L
Petrol, Diagnosis and
Testing).

P0481- Fan 2 Control Circuit - NOTE: Using the manufacturer


16 Circuit voltage below approved diagnostic
threshold - Circuit RAD_FAN_PWM - system check
datalogger signal,
Charging system fault Electric Fan PWM
Discharged battery Control - Commanded
Duty Cycle (0x03F9)
Refer to the electrical
circuit diagrams and
check charging circuit
for open circuit, short
circuit to ground
If fault persists, refer to
the relevant section of
the workshop manual
and refer to the cooling
fan pinpoint test
procedures For
additional information,
refer to: Engine Cooling
(303-03D Engine
Cooling - V8 N/A 5.0L
Petrol/V8 S/C 5.0L
Petrol, Diagnosis and
Testing).
Check and install a new
generator as required
Check and install a new
battery as required
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component
P0481- Fan 2 Control Circuit - NOTE: Using the manufacturer
17 Circuit voltage above approved diagnostic
threshold - Circuit RAD_FAN_PWM - system check
datalogger signal,
Charging system fault Electric Fan PWM
Discharged battery Control - Commanded
Duty Cycle (0x03F9)
Refer to the electrical
circuit diagrams and
check charging circuit
for open circuit, short
circuit to ground
If fault persists, refer to
the relevant section of
the workshop manual
and refer to the cooling
fan pinpoint test
procedures For
additional information,
refer to: Engine Cooling
(303-03D Engine
Cooling - V8 N/A 5.0L
Petrol/V8 S/C 5.0L
Petrol, Diagnosis and
Testing).
Check and install a new
generator as required
Check and install a new
battery as required
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0481- Fan 2 Control Circuit - NOTE: Using the manufacturer


38 Signal frequency incorrect approved diagnostic
- Circuit RAD_FAN_PWM - system check
datalogger signal,
Damaged cooling fan control unit Electric Fan PWM
Cooling fan control unit failure Control - Commanded
Duty Cycle (0x03F9)
If fault persists, refer to
the relevant section of
the workshop manual
and refer to the cooling
fan pinpoint test
procedures For
additional information,
refer to: Engine Cooling
(303-03D Engine
Cooling - V8 N/A 5.0L
Petrol/V8 S/C 5.0L
Petrol, Diagnosis and
Testing).
Check and install a new
cooling fan control unit
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0481- Fan 2 Control Circuit - NOTE: Using the manufacturer


4B Over temperature approved diagnostic
- Circuit RAD_FAN_PWM - system check
datalogger signal,
Damaged cooling fan control unit Electric Fan PWM
Cooling fan control unit failure Control - Commanded
Duty Cycle (0x03F9)
If fault persists, refer to
the relevant section of
the workshop manual
and refer to the cooling
fan pinpoint test
procedures For
additional information,
refer to: Engine Cooling
(303-03D Engine
Cooling - V8 N/A 5.0L
Petrol/V8 S/C 5.0L
Petrol, Diagnosis and
Testing).
Check and install a new
cooling fan control unit
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0481- Fan 2 Control Circuit - No NOTE: Using the manufacturer


93 operation approved diagnostic
- Circuit RAD_FAN_PWM - system check
datalogger signal,
Damaged cooling fan control unit Electric Fan PWM
Blocked cooling fan control unit Control - Commanded
Cooling fan control unit failure Duty Cycle (0x03F9)
Check for blocked or
obstruction to fan rotor
If fault persists, refer to
the relevant section of
the workshop manual
and refer to the cooling
fan pinpoint test
procedures For
additional information,
refer to: Engine Cooling
(303-03D Engine
Cooling - V8 N/A 5.0L
Petrol/V8 S/C 5.0L
Petrol, Diagnosis and
Testing).
Check and install a new
cooling fan control unit
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0481- Fan 2 Control Circuit - NOTE: Using the manufacturer


96 Component internal failure approved diagnostic
- Circuit RAD_FAN_PWM - system check
datalogger signal,
Damaged cooling fan control unit Electric Fan PWM
Cooling fan control unit failure Control - Commanded
Duty Cycle (0x03F9)
If fault persists, refer to
the relevant section of
the workshop manual
and refer to the cooling
fan pinpoint test
procedures For
additional information,
refer to: Engine Cooling
(303-03D Engine
Cooling - V8 N/A 5.0L
Petrol/V8 S/C 5.0L
Petrol, Diagnosis and
Testing).
Check and install a new
cooling fan control unit
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0481- Fan 2 Control Circuit - NOTE: Using the manufacturer


97 Component or system approved diagnostic
operation obstructed or - Circuit RAD_FAN_PWM - system check
blocked datalogger signal,
Damaged cooling fan control unit Electric Fan PWM
Blocked cooling fan control unit Control - Commanded
Cooling fan control unit failure Duty Cycle (0x03F9)
Check for blocked or
obstruction to fan rotor
If fault persists, refer to
the relevant section of
the workshop manual
and refer to the cooling
fan pinpoint test
procedures For
additional information,
refer to: Engine Cooling
(303-03D Engine
Cooling - V8 N/A 5.0L
Petrol/V8 S/C 5.0L
Petrol, Diagnosis and
Testing).
Check and install a new
cooling fan control unit
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0500- Vehicle Speed Sensor A - Wheel speed sensor fault Check anti-lock braking
81 Invalid serial data received system module for
related DTCs and refer
to relevant DTC index

P0500- Vehicle Speed Sensor A - Anti-lock braking system module not Check anti-lock braking
82 Alive / sequence counter on bus system module and
incorrect / not updated engine control module
for related DTCs and
refer to relevant DTC
index
Refer to the electrical
circuit diagrams and
check anti-lock braking
system module circuit
for short circuit to
ground, short circuit to
power, open circuit

P0500- Vehicle Speed Sensor A - Incorrect level of anti-lock braking Clear DTC and re-test
83 Value of signal protection system module software Using the manufacturer
calculation incorrect Incorrect level of engine control approved diagnostic
module software system check and install
latest relevant level of
software to the anti-lock
braking system module
Using the manufacturer
approved diagnostic
system check and install
latest relevant level of
software to the engine
control module

P0500- Vehicle Speed Sensor A - Anti-lock braking system module has Check anti-lock braking
85 Signal above allowable reported a speed above 300 km/h system module for
range related DTCs and refer
to relevant DTC index

P0501- Vehicle Speed Sensor A Vehicle speed from the anti-lock Check engine control
62 Range/Performance - braking system module does not match module for related
Signal compare failure the calculated vehicle speed from the vehicle speed DTCs and
engine control module refer to relevant DTC
index
Check anti-lock braking
system module and
transmission control
module for related
DTCs and refer to
relevant DTC index
Check the vehicle tire
sizes are correct

P0504- Brake Switch A / B No brake pressure signal available Check Anti-Lock


00 Correlation - No sub type from anti-lock braking module braking module for
information Brake switch 1 and Brake switch 2 related DTCs and refer
sense circuit short circuit to ground, to relevant DTC index
short circuit to power, open circuit Check for brake fluid
Brake switch 1 failure leaks
Refer to the electrical
circuit diagrams and
check anti-lock braking
system module circuit
for short circuit to
ground, short circuit to
power, open circuit
Refer to the electrical
circuit diagrams and
check brake switch
circuit for short circuit
to ground, short circuit
to power, open circuit
Check and install a new
brake switch 1 as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0504- Brake Switch A / B NOTE: Check for brake fluid


64 Correlation - Signal leaks
plausibility failure - Circuit BRAKE_SW - BRAKE_SW_2 - Refer to the electrical
circuit diagrams and
Brake fluid leak check brake switch 1
Brake switch incorrectly circuit for short circuit
installed/adjusted to brake switch 2
Brake switch 1 sense circuit short Check brake switch is
circuit to Brake switch 2 sense correctly installed and
Brake switch failure adjusted
Check and install a new
brake switch as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0506- Idle Air Control System Air intake restriction Ensure the air intake
00 RPM Lower Than Front end accessory drive overload system is free from
Expected - No sub type (defective/seized component) restriction
information Check the front end
accessory drive belt and
components for failure,
repair as required

P0506- Idle Air Control System Air intake restriction Ensure the air intake
24 RPM Lower Than Air intake system air leak between system is free from
Expected - Signal stuck MAF/IAT sensor and throttle restriction
high Intake air leak between throttle and Check for air leak
manifold between MAF/IAT
Engine crankcase breather leak sensor and throttle
Front end accessory drive overload Check for air leak
(defective/seized component) between throttle and
inlet manifold
Check for engine
breather system leak
Check the front end
accessory drive belt and
components for failure

P0507- Idle Air Control System Air intake system air leak between Check for air leak
00 RPM Higher Than MAF/IAT sensor and throttle between MAF/IAT
Expected - No sub type Intake air leak between throttle and sensor and throttle
information manifold Check for air leak
Engine crankcase breather leak between throttle and
inlet manifold
Check for engine
breather system leak

P0507- Idle Air Control System Air intake restriction Ensure the air intake
23 RPM Higher Than Air intake system air leak between system is free from
Expected - Signal stuck MAF/IAT sensor and throttle restriction
low Intake air leak between throttle and Check for air leak
manifold between MAF/IAT
Engine crankcase breather leak sensor and throttle
Check for air leak
between throttle and
inlet manifold
Check for engine
breather system leak

P050B- Cold Start Ignition Timing Ignition coil(s)faulty Refer to the electrical
23 Performance - Signal stuck Ignition coils circuit noise circuit diagrams and
low Engine control module failure check ignition coil
circuit for short circuit
to ground, short circuit
to power, open circuit
Refer to the electrical
circuit diagrams and
check engine control
module to ignition coil
circuit for short circuit
to power
Check and install a new
coil(s) as required
Refer to the electrical
circuit diagrams and
check ignition coils
circuit for corrosion,
high resistance
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P050B- Cold Start Ignition Timing Ignition coil(s)faulty Refer to the electrical
24 Performance - Signal stuck Ignition coils circuit noise circuit diagrams and
high Engine control module failure check ignition coil
circuit for short circuit
to ground, short circuit
to power, open circuit
Refer to the electrical
circuit diagrams and
check engine control
module to ignition coil
circuit for short circuit
to power
Check and install a new
coil(s) as required
Refer to the electrical
circuit diagrams and
check ignition coils
circuit for corrosion,
high resistance
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P050E- Cold Start Engine Exhaust Incorrect coolant temperature sensor Check the correct
00 Temperature Too Low - installed coolant temperature
No sub type information Coolant temperature sensor circuit sensor is installed
short circuit to ground, open circuit Refer to the electrical
Coolant temperature sensor failure circuit diagrams and
check coolant
temperature sensor
circuit for short circuit
to ground, open circuit
Check and install a new
coolant temperature
sensor as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0512- Starter Request Circuit - NOTE: Refer to the electrical


12 Circuit short to battery circuit diagrams and
- Circuit CRANK_REQUEST - check crank request
circuit between engine
Crank request circuit between engine control module and
control module and central junction central junction box for
box short circuit to power short circuit to power

P0512- Starter Request Circuit - NOTE: Refer to the electrical


14 Circuit short to ground or circuit diagrams and
open - Circuit CRANK_REQUEST - check crank request
circuit between engine
Crank request circuit between engine control module and
control module and central junction central junction box for
box short circuit to ground, open short circuit to ground,
circuit open circuit

P0513- Incorrect Immobilizer Key Security key invalid Check for CAN
00 - No sub type information Controller area network data network
corruption interference/engine
Low battery voltage control module related
error
Using the manufacturer
approved diagnostic
system, complete a
CAN network integrity
test
Check the vehicle
charging system for
faults, repair as required

P052A- Cold Start Intake (A) NOTE: Check engine oil level
00 Camshaft Position Timing and top up as required
Over-Advanced (Bank 1) - - Circuit CAM_IN_SENSOR_A - Refer to the electrical
No sub type information circuit diagrams and
Engine oil pressure too low check intake valve
Intake valve solenoid 1 circuit short solenoid 1 sensor circuit
circuit to ground, open circuit, high for short circuit to
resistance ground, open circuit,
Intake valve solenoid 1 failure high resistance
Timing chains stretched beyond Check and install a new
allowable limits intake valve solenoid 1
sensor as required
Check service history
/mileage
Check and install new
timing chains as
required
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P052B- Cold Start Intake (A) NOTE: Check engine oil level
00 Camshaft Position Timing and top up as required
Over-Retarded (Bank 1) - - Circuit CAM_IN_SENSOR_A - Refer to the electrical
No sub type information circuit diagrams and
Engine oil pressure too low check intake valve
Intake valve solenoid 1 circuit short solenoid 1 sensor circuit
circuit to ground, open circuit, high for short circuit to
resistance ground, open circuit,
Intake valve solenoid 1 failure high resistance
Timing chains stretched beyond Check and install a new
allowable limits intake valve solenoid 1
sensor as required
Check service history
/mileage
Check and install new
timing chains as
required
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component
P052C- Cold Start Intake (A) NOTE: Check engine oil level
00 Camshaft Position Timing and top up as required
Over-Advanced (Bank 2) - - Circuit CAM_IN_SENSOR_B - Refer to the electrical
No sub type information circuit diagrams and
Engine oil pressure too low check intake valve
Intake valve solenoid 2 circuit short solenoid 2 sensor circuit
circuit to ground, open circuit, high for short circuit to
resistance ground, open circuit,
Intake valve solenoid 2 failure high resistance
Timing chains stretched beyond Check and install a new
allowable limits intake valve solenoid 2
sensor as required
Check service history
/mileage
Check and install new
timing chains as
required
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P052D- Cold Start Intake (A) NOTE: Check engine oil level
00 Camshaft Position Timing and top up as required
Over-Retarded (Bank 2) - - Circuit CAM_IN_SENSOR_B - Refer to the electrical
No sub type information circuit diagrams and
Engine oil pressure too low check intake valve
Intake valve solenoid 2 circuit short solenoid 2 sensor circuit
circuit to ground, open circuit, high for short circuit to
resistance ground, open circuit,
Intake valve solenoid 2 failure high resistance
Timing chains stretched beyond Check and install a new
allowable limits intake valve solenoid 2
sensor as required
Check service history
/mileage
Check and install new
timing chains as
required
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P054A- Cold Start Exhaust (B) NOTE: Check engine oil level
00 Camshaft Position Timing and top up as required
Over-Advanced (Bank 1) - - Circuit CAM_EX_SENSOR_A - Refer to the electrical
No sub type information circuit diagrams and
Engine oil pressure too low check exhaust valve
Exhaust valve solenoid 1 circuit short solenoid 1 sensor circuit
circuit to ground, open circuit, high for short circuit to
resistance ground, open circuit,
Exhaust valve solenoid 1 failure high resistance
Timing chains stretched beyond Check and install a new
allowable limits exhaust valve solenoid
1 sensor as required
Check service history
/mileage
Check and install new
timing chains as
required
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P054B- Cold Start Exhaust (B) NOTE: Check engine oil level
00 Camshaft Position Timing and top up as required
Over-Retarded (Bank 1) - - Circuit CAM_EX_SENSOR_A - Refer to the electrical
No sub type information circuit diagrams and
Engine oil pressure too low check exhaust valve
Exhaust valve solenoid 1 circuit short solenoid 1 sensor circuit
circuit to ground, open circuit, high for short circuit to
resistance ground, open circuit,
Exhaust valve solenoid 1 failure high resistance
Timing chains stretched beyond Check and install a new
allowable limits exhaust valve solenoid
1 sensor as required
Check service history
/mileage
Check and install new
timing chains as
required
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P054C- Cold Start Exhaust (B) NOTE: Check engine oil level
00 Camshaft Position Timing and top up as required
Over-Advanced (Bank 2) - - Circuit CAM_EX_SENSOR_B - Refer to the electrical
No sub type information circuit diagrams and
Engine oil pressure too low check exhaust valve
Exhaust valve solenoid 2 circuit short solenoid 2 sensor circuit
circuit to ground, open circuit, high for short circuit to
resistance ground, open circuit,
Exhaust valve solenoid 2 failure high resistance
Timing chains stretched beyond Check and install a new
allowable limits exhaust valve solenoid
2 sensor as required
Check service history
/mileage
Check and install new
timing chains as
required
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P054D- Cold Start Exhaust (B) NOTE: Check engine oil level
00 Camshaft Position Timing and top up as required
Over-Retarded (Bank 2) - - Circuit CAM_EX_SENSOR_B - Refer to the electrical
No sub type information circuit diagrams and
Engine oil pressure too low check exhaust valve
Exhaust valve solenoid 2 circuit short solenoid 2 sensor circuit
circuit to ground, open circuit, high for short circuit to
resistance ground, open circuit,
Exhaust valve solenoid 2 failure high resistance
Timing chains stretched beyond Check and install a new
allowable limits exhaust valve solenoid
2 sensor as required
Check service history
/mileage
Check and install new
timing chains as
required
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0560- System Voltage - Circuit NOTE: Refer to the electrical


13 open circuit diagrams and
- Circuit BATTERY - check engine control
module power supply
Engine control module power supply circuit for open circuit
circuit, open circuit Refer to the electrical
Engine control module battery monitor circuit diagrams and
disconnected check engine control
module battery monitor
circuit for open circuit

P0562- System Voltage Low - No NOTE: Refer to the electrical


00 sub type information circuit diagrams and
- Circuit BATTERY - check battery circuit for
high resistance
Battery circuit high resistance Refer to the electrical
Generator circuit open circuit, high circuit diagrams and
resistance check generator circuit
Generator failure for open circuit, high
resistance
Check and install a new
generator as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0563- System Voltage High - No NOTE: Refer to the electrical


00 sub type information circuit diagrams and
- Circuit BATTERY - check battery circuit for
high resistance
Battery circuit high resistance Check and install a new
Generator over charging generator as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0572- Brake Switch A Circuit NOTE: Refer to the electrical


17 Low - Circuit voltage circuit diagrams and
above threshold - Circuit BRAKE_SW - check brake switch 2
circuit for short circuit
Brake switch 2 sense circuit short to ground
circuit to ground Check brake switch is
Brake switch incorrectly correctly installed and
installed/adjusted adjusted
Customer is driving with foot resting Ensure customer is not
on brake pedal driving with foot resting
Brake switch 2 failure on brake pedal
Check and install a new
brake switch as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0573- Brake Switch A Circuit NOTE: Refer to the electrical


16 High - Circuit voltage circuit diagrams and
below threshold - Circuit BRAKE_SW - check brake switch 1
circuit for open circuit
Brake switch 1 sense circuit short Refer to the electrical
circuit to ground circuit diagrams and
Brake switch 2 sense circuit open check brake switch 2
circuit circuit for open circuit
Brake switch incorrectly Check brake switch is
installed/adjusted correctly installed and
Customer is driving with foot resting adjusted
on brake pedal Ensure customer is not
Brake switch 2 failure driving with foot resting
on brake pedal
Check and install a new
brake switch as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0578- Cruise Control Multi- Speed control circuit, output signal Refer to the electrical
00 Function Input A Circuit stuck circuit diagrams and
Stuck - No sub type Speed control switch stuck check speed control
information switch circuit for short
circuit to ground
Check for stuck speed
control switch, install a
new switch pack as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P057B- Brake Pedal Position Brake pressure signal missing from Check the anti-lock
87 Sensor Circuit anti-lock braking system control braking system control
Range/Performance - module module for related
Missing message DTCs and refer to the
relevant DTC index

P0590- Cruise Control Multi- Active speed limiter switch stuck Check for active speed
00 Function Input B Circuit limiter DTCs within
Stuck - No sub type gear shift module
information Check and install a new
gear shift module as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0600- Serial Communication Corrupt engine control module Using the manufacturer
49 Link - Internal electronic software approved diagnostic
failure Engine control module power supply system check and install
fault latest relevant level of
Engine control module damage software to the engine
through water ingress control module
Check engine control
module power supply
circuit for open circuit
Check engine control
module for signs of
water ingress
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0601- Internal Control Module Corrupt engine control module Using the manufacturer
43 Memory Check Sum Error software flash approved diagnostic
- Special memory failure Engine control module power supply system check and install
fault latest relevant level of
Engine control module damage software to the engine
through water ingress control module
Check engine control
module power supply
circuit for open circuit
Check engine control
module for signs of
water ingress
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0601- Internal Control Module Corrupt engine control module Using the manufacturer
45 Memory Check Sum Error software flash approved diagnostic
- Program memory failure Engine control module power supply system check and install
fault latest relevant level of
Engine control module damage software to the engine
through water ingress control module
Check engine control
module power supply
circuit for open circuit
Check engine control
module for signs of
water ingress
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0604- Internal Control Module Corrupt engine control module Using the manufacturer
42 Random Access Memory software flash approved diagnostic
(RAM) Error - General Engine control module power supply system check and install
memory failure fault latest relevant level of
Engine control module damage software to the engine
through water ingress control module
Check engine control
module power supply
circuit for open circuit
Check engine control
module for signs of
water ingress
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0604- Internal Control Module Corrupt engine control module Using the manufacturer
43 Random Access Memory software flash approved diagnostic
(RAM) Error - Special Engine control module power supply system check and install
memory failure fault latest relevant level of
Engine control module damage software to the engine
through water ingress control module
Check engine control
module power supply
circuit for open circuit
Check engine control
module for signs of
water ingress
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0604- Internal Control Module Corrupt engine control module Using the manufacturer
44 Random Access Memory software flash approved diagnostic
(RAM) Error - Data Engine control module power supply system check and install
memory failure fault latest relevant level of
Engine control module damage software to the engine
through water ingress control module
Check engine control
module power supply
circuit for open circuit
Check engine control
module for signs of
water ingress
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0605- Internal Control Module Corrupt engine control module Using the manufacturer
00 Read Only Memory software flash approved diagnostic
(ROM) Error - No sub type Engine control module power supply system check and install
information fault latest relevant level of
Engine control module damage software to the engine
through water ingress control module
Check engine control
module power supply
circuit for open circuit
Check engine control
module for signs of
water ingress
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0605- Internal Control Module Corrupt engine control module Using the manufacturer
29 Read Only Memory software flash approved diagnostic
(ROM) Error - Signal Engine control module power supply system check and install
invalid fault latest relevant level of
Engine control module damage software to the engine
through water ingress control module
Check engine control
module power supply
circuit for open circuit
Check engine control
module for signs of
water ingress
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0605- Internal Control Module Corrupt engine control module Using the manufacturer
42 Read Only Memory software flash approved diagnostic
(ROM) Error - General Engine control module power supply system check and install
memory failure fault latest relevant level of
Engine control module damage software to the engine
through water ingress control module
Check engine control
module power supply
circuit for open circuit
Check engine control
module for signs of
water ingress
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0605- Internal Control Module Corrupt engine control module Using the manufacturer
44 Read Only Memory software flash approved diagnostic
(ROM) Error - Data Engine control module power supply system check and install
memory failure fault latest relevant level of
Engine control module damage software to the engine
through water ingress control module
Check engine control
module power supply
circuit for open circuit
Check engine control
module for signs of
water ingress
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0605- Internal Control Module Corrupt engine control module Using the manufacturer
46 Read Only Memory software flash approved diagnostic
(ROM) Error - Calibration Engine control module power supply system check and install
/ parameter memory failure fault latest relevant level of
Engine control module damage software to the engine
through water ingress control module
Check engine control
module power supply
circuit for open circuit
Check engine control
module for signs of
water ingress
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0605- Internal Control Module Corrupt engine control module Using the manufacturer
48 Read Only Memory software flash approved diagnostic
(ROM) Error - Supervision Engine control module power supply system check and install
software failure fault latest relevant level of
Engine control module damage software to the engine
through water ingress control module
Check engine control
module power supply
circuit for open circuit
Check engine control
module for signs of
water ingress
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0605- Internal Control Module Corrupt engine control module Using the manufacturer
64 Read Only Memory software flash approved diagnostic
(ROM) Error - Signal Engine control module power supply system check and install
plausibility failure fault latest relevant level of
Engine control module damage software to the engine
through water ingress control module
Check engine control
module power supply
circuit for open circuit
Check engine control
module for signs of
water ingress
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0606- Control Module Processor Corrupt engine control module Using the manufacturer
01 - General electrical failure software flash approved diagnostic
Engine control module power supply system check and install
fault latest relevant level of
Engine control module damage software to the engine
through water ingress control module
Check engine control
module power supply
circuit for open circuit
Check engine control
module for signs of
water ingress
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0606- Control Module Processor Corrupt engine control module Using the manufacturer
04 - System internal failures software flash approved diagnostic
Engine control module power supply system check and install
fault latest relevant level of
Engine control module damage software to the engine
through water ingress control module
Check engine control
module power supply
circuit for open circuit
Check engine control
module for signs of
water ingress
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0606- Control Module Processor Corrupt engine control module Using the manufacturer
05 - System programming software flash approved diagnostic
failures Engine control module power supply system check and install
fault latest relevant level of
Engine control module damage software to the engine
through water ingress control module
Check engine control
module power supply
circuit for open circuit
Check engine control
module for signs of
water ingress
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0606- Control Module Processor Corrupt engine control module Using the manufacturer
41 - General checksum failure software flash approved diagnostic
Engine control module power supply system check and install
fault latest relevant level of
Engine control module damage software to the engine
through water ingress control module
Check engine control
module power supply
circuit for open circuit
Check engine control
module for signs of
water ingress
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0606- Control Module Processor Corrupt engine control module Using the manufacturer
42 - General memory failure software flash approved diagnostic
Engine control module power supply system check and install
fault latest relevant level of
Engine control module damage software to the engine
through water ingress control module
Check engine control
module power supply
circuit for open circuit
Check engine control
module for signs of
water ingress
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0606- Control Module Processor Corrupt engine control module Using the manufacturer
43 - Special memory failure software flash approved diagnostic
Engine control module power supply system check and install
fault latest relevant level of
Engine control module damage software to the engine
through water ingress control module
Check engine control
module power supply
circuit for open circuit
Check engine control
module for signs of
water ingress
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0606- Control Module Processor Corrupt engine control module Using the manufacturer
44 - Data memory failure software flash approved diagnostic
Engine control module power supply system check and install
fault latest relevant level of
Engine control module damage software to the engine
through water ingress control module
Check engine control
module power supply
circuit for open circuit
Check engine control
module for signs of
water ingress
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0606- Control Module Processor Corrupt engine control module Using the manufacturer
47 - Watchdog / safety micro software flash approved diagnostic
controller failure Engine control module power supply system check and install
fault latest relevant level of
Engine control module damage software to the engine
through water ingress control module
Check engine control
module power supply
circuit for open circuit
Check engine control
module for signs of
water ingress
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0606- Control Module Processor Corrupt engine control module Using the manufacturer
48 - Supervision software software flash approved diagnostic
failure Engine control module power supply system check and install
fault latest relevant level of
Engine control module damage software to the engine
through water ingress control module
Check engine control
module power supply
circuit for open circuit
Check engine control
module for signs of
water ingress
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0606- Control Module Processor Corrupt engine control module Using the manufacturer
49 - Internal electronic failure software flash approved diagnostic
Engine control module power supply system check and install
fault latest relevant level of
Engine control module damage software to the engine
through water ingress control module
Check engine control
module power supply
circuit for open circuit
Check engine control
module for signs of
water ingress
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0607- Control Module Corrupt engine control module Using the manufacturer
00 Performance - No sub type software flash approved diagnostic
information Engine control module power supply system check and install
fault latest relevant level of
Engine control module damage software to the engine
through water ingress control module
Check engine control
module power supply
circuit for open circuit
Check engine control
module for signs of
water ingress
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0610- Control Module Vehicle Corrupt engine control module Clear the DTC and re-
43 Options Error - Special software flash test
memory failure Corrupt rear junction box software Using the manufacturer
flash approved diagnostic
Corrupt central junction box software system check and install
flash latest relevant level of
software to the engine
control module
Re-configure the rear
junction box using the
manufacturer approved
diagnostic system
Re-configure the central
junction box using the
manufacturer approved
diagnostic system
P0615- Starter Relay Circuit - NOTE: Refer to the electrical
13 Circuit open circuit diagrams and
- Circuit STARTER_RELAY_NEG - check starter relay
control circuit for open
Starter relay control circuit open circuit circuit
Starter relay failure Check and install a new
starter relay as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0616- Starter Relay Circuit Low - NOTE: Refer to the electrical


11 Circuit short to ground circuit diagrams and
- Circuit STARTER_RELAY_NEG - check starter relay
control circuit for short
Starter relay control circuit short circuit to ground
circuit to ground Check and install a new
Starter relay failure starter relay as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0617- Starter Relay Circuit High NOTE: Refer to the electrical


12 - Circuit short to battery circuit diagrams and
- Circuit STARTER_RELAY_NEG - check starter relay
control circuit for short
Starter relay control circuit short circuit to power
circuit to power Check and install a new
Starter relay failure starter relay as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P061A- Internal Control Module Manifold air flow sensor(s) failure Check for related DTCs
00 Torque Performance - No Electronic throttle unit failure Check manifold air flow
sub type information sensors are reading
correctly
Check and install a new
manifold air flow
sensor(s) as required
Check throttle position
sensors are reading the
same position
Check throttle body is
clear of any deposits
Check and install a new
electronic throttle unit
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P061A- Internal Control Module Manifold air flow sensor(s) failure Check for related DTCs
04 Torque Performance - Electronic throttle unit failure Check manifold air flow
System internal failures sensors are reading
correctly
Check and install a new
manifold air flow
sensor(s) as required
Check throttle position
sensors are reading the
same position
Check throttle body is
clear of any deposits
Check and install a new
electronic throttle unit
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P061A- Internal Control Module Intake system air leak Check for related DTCs
29 Torque Performance - Manifold air flow sensor(s) failure Check intake air system
Signal invalid Throttle position sensors are reading for leaks
incorrectly Check manifold air flow
Electronic throttle unit failure sensors are reading
Atmospheric pressure sensor failure correctly
Check and install a new
air flow sensor(s) as
required
Check throttle position
sensors are reading the
same position
Check throttle body is
clear of any deposits
Check and install a new
electronic throttle unit
as required
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P061A- Internal Control Module Intake system air leak Check for related DTCs
64 Torque Performance - Manifold air flow sensor(s) failure Check intake air system
Signal plausibility failure for leaks and is
correctly installed
Check manifold air flow
sensors are reading
correctly
Check and install a new
manifold air flow
sensor(s) as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P061B- Internal Control Module Intake system air leak Check intake air system
62 Torque Calculation Engine breather system leak for leaks
Performance - Signal Manifold air flow sensor failure Check engine breather
compare failure Electronic throttle unit failure system for leaks
Throttle position sensors are reading Check throttle position
incorrectly sensors are reading the
Atmospheric pressure sensor failure same position
Check and install a new
manifold air flow sensor
as required
Check and install a new
electronic throttle unit
as required
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0620- Generator Control Circuit - NOTE: Check for good/clean


01 General electrical failure contact at generator B+
- Circuit LIN_A - and battery terminal
connectors
Generator B+ or battery terminal Refer to the electrical
disconnected/poor connection circuit diagrams and
Charging circuit short, open circuit check charging circuit
Generator failure for short circuit, open
circuit
Clear DTC and repeat
automated diagnostic
procedure using the
manufacturer approved
diagnostic system
If DTC remains, check
and install a new
generator as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0627- Fuel Pump A Control High pressure fuel pump 1 circuit to Refer to the electrical
00 Circuit / Open - No sub engine control module short circuit to circuit diagrams and
type information ground, short circuit to power, open check high pressure fuel
circuit, high resistance pump 1 to engine
control module circuit
for short circuit to
ground, short circuit to
power, open circuit,
high resistance
Using the Jaguar Land
Rover approved
diagnostic equipment,
perform routine - Inline
diagnostic unit 2 non-
intrusive test - Low
pressure fuel pump

P062A- Fuel Pump A Control Invalid fuel pump duty requested by Refer to the electrical
00 Circuit Range/Performance the engine control module circuit diagrams and
- No sub type information check the fuel pump
driver module circuit
for short circuit to
ground, short circuit to
power, open circuit,
high resistance
Using the Jaguar Land
Rover approved
diagnostic equipment,
perform routine - Inline
diagnostic unit 2 non-
intrusive test - Low
pressure fuel pump

P0630- VIN Not Programmed or Car configuration file to CAN VIN Using the manufacturer
00 Incompatible - ECM/PCM mismatch approved diagnostic
- No sub type information New engine control module fitted and system check and install
incorrectly configured latest relevant level of
New central junction box fitted and software to the engine
incorrectly configured control module, clear
DTC and re-test
Re-configure the central
junction box using the
manufacturer approved
diagnostic system, clear
DTC and re-test

P0634- PCM / ECM/ TCM Engine control module internal Clear the DTC. With
22 Internal Temperature Too temperature too high the ignition off, wait 10
High - Signal amplitude > minutes and re-check
maximum DTC
Check the engine
control module does not
have additional external
covering or obstructions
which may cause
overheating
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0634- PCM / ECM / TCM Engine control module internal Clear the DTC. With
4B Internal Temperature A temperature too high the ignition off, wait 10
Too High - Over minutes and re-check
temperature DTC
Check the engine
control module does not
have additional external
covering or obstructions
which may cause
overheating
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0642- Sensor Reference Voltage NOTE: Refer to the electrical


00 A Circuit Low - No sub circuit diagrams and
type information - Circuit SENSOR_5V_SUPPLY - check 5V supply circuit
for short circuit to
Short circuit to power of a 5V output ground open circuit,
pin, either in the harness, or a high resistance, terminal
connector damage or corrosion
Internal short circuit in a faulty Check engine control
component module for sensor
related DTCs and refer
to the relevant DTC
index

P0643- Sensor Reference Voltage NOTE: Refer to the electrical


00 A Circuit High - No sub circuit diagrams and
type information - Circuit SENSOR_5V_SUPPLY - check 5V supply circuit
for short circuit to
Short circuit to ground of a 5V output power open circuit, high
pin, either in the harness, or a resistance, terminal
connector damage or corrosion
Internal short circuit in a faulty Check engine control
component module for sensor
related DTCs and refer
to the relevant DTC
index

P0657- Actuator Supply Voltage A NOTES: Refer to the electrical


13 Circuit / Open - Circuit circuit diagrams and
open Jaguar - Circuit IMTV - check intake manifold
tuning solenoid circuit
LR - Circuit MANIFOLD TUNING for open circuit
VALVE -

Intake manifold tuning solenoid


circuit, open circuit

P0658- Actuator Supply Voltage A NOTES: Refer to the electrical


11 Circuit Low - Circuit short circuit diagrams and
to ground Jaguar - Circuit IMTV - check intake manifold
tuning solenoid circuit
LR - Circuit MANIFOLD TUNING for short circuit to
VALVE - ground
Intake manifold tuning solenoid
circuit, short circuit to ground

P0659- Actuator Supply Voltage A NOTES: Refer to the electrical


12 Circuit High - Circuit short circuit diagrams and
to battery Jaguar - Circuit IMTV - check intake manifold
tuning solenoid circuit
LR - Circuit MANIFOLD TUNING for short circuit to
VALVE - power
Intake manifold tuning solenoid
circuit, short circuit to power

P065B- Generator Control Circuit NOTE: Check for good/clean


16 Range/Performance - contact at generator B+
Circuit voltage below - Circuit LIN_A - and battery terminal
threshold connectors
Generator B+ or battery terminal Refer to the electrical
disconnected/poor connection circuit diagrams and
Charging circuit short, open circuit check charging circuit
Generator failure for short circuit, open
Battery failure circuit
Ensure the battery is in
a fully charged and
serviceable condition.
Refer to the battery care
manual and the relevant
sections of the
workshop manual
Clear DTC and repeat
automated diagnostic
procedure using the
manufacturer approved
diagnostic system. If
DTC remains, check
and install a new
generator as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P065B- Generator Control Circuit NOTE: Check for good/clean


17 Range/Performance - contact at generator B+
Circuit voltage above - Circuit LIN_A - and battery terminal
threshold connectors
Charging circuit short circuit to power Refer to the electrical
Generator failure circuit diagrams and
Battery failure check charging circuit
for short circuit, open
circuit
Ensure the battery is in
a fully charged and
serviceable condition.
Refer to the battery care
manual and the relevant
sections of the
workshop manual
Clear DTC and repeat
automated diagnostic
procedure using the
manufacturer approved
diagnostic system. If
DTC remains, check
and install a new
generator as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P065C- Generator Mechanical NOTE: Check front end


00 Performance - No sub type accessory belt for
information - Circuit LIN_A - condition/contamination
and correct tension
Poor front end accessory belt tension Check generator pulley
Generator pulley loose/failure for failure
Generator failure Clear DTC and repeat
automated diagnostic
procedure using
manufacturer approved
diagnostic system
If DTC remains check
and install a new
generator as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0668- PCM / ECM / TCM Engine control module internal Check and install a new
00 Internal Temperature temperature sensor failure engine control module
Sensor A Circuit Low - No as required. Refer to the
sub type information warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0669- PCM / ECM / TCM Engine control module internal Check and install a new
00 Internal Temperature temperature sensor failure engine control module
Sensor A Circuit High - No as required. Refer to the
sub type information warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0687- ECM/PCM Power Relay NOTE: Refer to the electrical


73 Control Circuit High - circuit diagrams and
Actuator stuck closed - Circuit EMS_MAIN_RLY - check engine control
module relay circuit for
Engine control module relay circuit short circuit to power
short circuit to power Check and install a new
Engine control module relay failure engine control module
relay as required. Refer
to the warranty policy
and procedures manual,
or determine if any
prior approval
programme is in
operation, prior to the
installation of a new
module/component

P0695- Fan 3 Control Circuit Low NOTE: Refer to the electrical


00 - No sub type information circuit diagrams and
- Circuit E_BOX_FAN - check E-Box cooling
fan circuit for short
E-Box cooling fan circuit short circuit circuit to ground
to ground Check and install a new
E-Box cooling fan failure E-Box cooling fan as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0696- Fan 3 Control Circuit High NOTE: Refer to the electrical


12 - Circuit short to battery circuit diagrams and
- Circuit E_BOX_FAN - check E-Box cooling
fan circuit for short
E-Box cooling fan circuit short circuit circuit to power
to power Check and install a new
E-Box cooling fan failure E-Box cooling fan as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0696- Fan 3 Control Circuit High NOTE: Refer to the electrical


13 - Circuit open circuit diagrams and
- Circuit E_BOX_FAN - check E-Box cooling
fan circuit for open
E-Box cooling fan circuit open circuit circuit
E-Box cooling fan failure Check and install a new
E-Box cooling fan as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0721- Output Shaft Speed Sensor Transmission control module has Check transmission
85 Circuit Range/Performance reported a fault in the shaft speed control module for
- Signal above allowable signal related DTCs and refer
range to relevant DTC index
P0721- Output Shaft Speed Sensor Transmission control module has taken Check transmission
86 Circuit Range/Performance to 8 seconds or longer to change range control module for
- Signal invalid related DTCs and refer
to relevant DTC index

P0724- Brake Switch B Circuit NOTE: Refer to the electrical


17 High - Circuit voltage circuit diagrams and
above threshold - Circuit BRAKE_SW - check brake switch 1
circuit for short circuit
Brake switch 1 sense circuit short to power
circuit to power Check brake switch is
Brake switch incorrectly correctly installed and
installed/adjusted adjusted
Customer is driving with foot resting Ensure customer is not
on brake pedal driving with foot resting
Brake switch 1 failure on brake pedal
Check and install a new
brake switch as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P0850- Park / Neutral Switch Input NOTE: Check gear shift module
86 Circuit - Signal invalid for related DTCs and
- Circuit PN_SW - refer to relevant DTC
index
Intermittent fault on Park/Neutral Refer to the electrical
signal from gear shift module circuit diagrams and
CAN network failure between gear check Park/Neutral
shift module and engine control switch input circuit for
module short circuit to ground,
short circuit to power,
open circuit
Using the manufacturer
approved diagnostic
system, complete a
CAN network integrity
test

P0850- Park / Neutral Switch Input NOTE: Check gear shift module
8F Circuit - Erratic for related DTCs and
- Circuit PN_SW - refer to relevant DTC
index
Intermittent fault on Park/Neutral Refer to the electrical
signal from gear shift module circuit diagrams and
CAN network failure between gear check Park/Neutral
shift module and engine control switch input circuit for
module short circuit to ground,
short circuit to power,
open circuit
Using the manufacturer
approved diagnostic
system, complete a
CAN network integrity
test

P0851- Park / Neutral Switch Input NOTE: Refer to the electrical


14 Circuit Low - Circuit short circuit diagrams and
to ground or open - Circuit PN_SW - check park/neutral
switch input circuit for
Park/Neutral switch input circuit short short circuit to ground,
circuit to ground, open circuit open circuit

P0852- Park / Neutral Switch Input NOTE: Refer to the electrical


12 Circuit Low - Circuit short circuit diagrams and
to battery - Circuit PN_SW - check park/neutral
switch input circuit for
Park/Neutral switch input circuit short short circuit to power
circuit to power

P0A1A- Generator Control Module NOTE: Check for good/clean


87 - Missing message contact at generator and
- Circuit LIN_A - engine control module
LIN circuit
Generator to engine control module connectors/pins
LIN circuit open circuit Refer to the electrical
circuit diagrams and
check generator circuit
for open circuit
Check for engine
control module
hardware DTCs and
refer to relevant DTC
index
Clear DTCs and repeat
automated diagnostic
procedure using the
manufacturer approved
diagnostic system

P0A1A- Generator Control Module NOTE: Check for good/clean


88 - Bus off contact at generator and
- Circuit LIN_A - engine control module
LIN circuit
Generator to engine control module connectors/pins
LIN circuit open circuit Refer to the electrical
circuit diagrams and
check generator circuit
for open circuit
Check for engine
control module
hardware DTCs and
refer to relevant DTC
index
Clear DTCs and repeat
automated diagnostic
procedure using the
manufacturer approved
diagnostic system

P0A3B- Generator Over Cooling fan not operating Check for correct
00 Temperature - No sub type Coolant level low cooling fan operation
information Check coolant level.
Clear DTC and re-test

P0A3B- Generator Over Cooling fan not operating Check for correct
68 Temperature - Event Coolant level low cooling fan operation
information Check coolant level.
Clear DTC and re-test

P115D- Mass Air Flow Circuit NOTE: Using the manufacturer


00 Offset - No sub type approved diagnostic
information - Circuit MAF_SENSOR_A - system check
MAF_SENSOR_B - datalogger signal, Mass
Air Flow Sensor 2
NOTE: Voltage (0x0503)
Check air cleaner for
Customer likely to report hesitation. blockage
Check air intake system
Air cleaner blocked for leaks
Air intake leak Check engine breather
Engine breather blocked system for blockages
Air intake blockage Check for carbon build
Carbon build up on throttle blade up on throttle blade
Mass air flow sensor circuit, high Check for related mass
resistance air flow DTCs P0102 or
Blocked catalyst(s) P0103
Mass air flow sensor failure Refer to the electrical
circuit diagrams and
check mass air flow
sensor circuit for high
resistance
Check and install a new
mass air flow sensor as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P1315- Persistent Misfire - No sub Engine control module to ignition coil Check for cylinder mis-
00 type information primary circuit fault (cylinder misfire fire, ignition and
detected DTC also flagged) injector DTCs and refer
Fuel injector circuit fault(s) (injector to the DTC index
DTCs also flagged) Refer to the electrical
Fuel delivery pressure low circuit diagrams and
Spark plug failure/fouled/incorrect gap check ignition coil
Ignition coil failure circuit for short circuit
Cylinder compression low to ground, short circuit
Exhaust system blockage to power, open circuit
Check for fuel system
failure
Check and install a new
spark plug(s) as
required
Check and install a new
ignition coil as required
Carry out cylinder
compression tests
Check exhaust system
for blockage
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P1316- Injector Driver Module Engine control module to ignition coil Check for cylinder mis-
00 Codes Detected - No sub primary circuit fault (cylinder misfire fire, ignition and
type information detected DTC also flagged) injector DTCs and refer
Fuel injector circuit fault(s) (injector to the DTC index
DTCs also flagged) Refer to the electrical
Fuel delivery pressure low circuit diagrams and
Spark plug failure/fouled/incorrect gap check ignition coil
Ignition coil failure circuit for short circuit
Cylinder compression low to ground, short circuit
Exhaust system blockage to power, open circuit
Check for fuel system
failure
Check and install a new
spark plug(s) as
required
Check and install a new
ignition coil as required
Carry out cylinder
compression tests
Check exhaust system
for blockage
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P1593- Cruise Control Monitor Speed control monitor fault. The Using the manufacturer
64 Fault - Signal plausibility engine control module performs a approved diagnostic
failure independent check of the cruise status system check and up-
date the car
configuration file as
required. Clear the DTC
and retest. If the
problem persists,
contact dealer technical
support

P1603- EEPROM Malfunction - Corrupt engine control module Using the manufacturer
00 No sub type information software flash approved diagnostic
Engine control module power supply system check and install
fault latest relevant level of
Engine control module damage software to the engine
through water ingress control module
Refer to the electrical
circuit diagrams and
check engine control
module power supply
circuit for open circuit
Check engine control
module for signs of
water ingress
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P2088- A Camshaft Position NOTE: Refer to the electrical


11 Actuator Control Circuit circuit diagrams and
Low Bank 1 - Circuit short - Circuit VFS_IN_A - check intake valve
to ground solenoid 1 for short
Intake valve solenoid 1 short circuit to circuit to ground
ground

P2089- A Camshaft Position NOTE: Refer to the electrical


12 Actuator Control Circuit circuit diagrams and
High Bank 1 - Circuit short - Circuit VFS_IN_A - check intake valve
to battery solenoid 1 for short
Intake valve solenoid 1 short circuit to circuit to power
power

P2090- B Camshaft Position NOTE: Refer to the electrical


11 Actuator Control Circuit circuit diagrams and
Low Bank 1 - Circuit short - Circuit VFS_EX_A - check exhaust valve
to ground solenoid 1 for short
Exhaust valve solenoid 1 short circuit circuit to ground
to ground

P2091- B Camshaft Position NOTE: Refer to the electrical


12 Actuator Control Circuit circuit diagrams and
High Bank 1 - Circuit short - Circuit VFS_EX_A - check exhaust valve
to battery solenoid 1 for short
Exhaust valve solenoid 1 short circuit circuit to power
to power

P2092- A Camshaft Position NOTE: Refer to the electrical


11 Actuator Control Circuit circuit diagrams and
Low Bank 2 - Circuit short - Circuit VFS_IN_B - check intake valve
to ground solenoid 2 for short
Intake valve solenoid 2 short circuit to circuit to ground
ground

P2093- A Camshaft Position NOTE: Refer to the electrical


12 Actuator Control Circuit circuit diagrams and
High Bank 2 - Circuit short - Circuit VFS_IN_B - check intake valve
to battery solenoid 2 for short
Intake valve solenoid 2 short circuit to circuit to power
power

P2094- B Camshaft Position NOTE: Refer to the electrical


11 Actuator Control Circuit circuit diagrams and
Low Bank 2 - Circuit short - Circuit VFS_EX_B - check exhaust valve
to ground solenoid 2 for short
Exhaust valve solenoid 2 short circuit circuit to ground
to ground

P2095- B Camshaft Position NOTE: Refer to the electrical


12 Actuator Control Circuit circuit diagrams and
High Bank 2 - Circuit short - Circuit VFS_EX_B - check exhaust valve
to battery solenoid 2 for short
Exhaust valve solenoid 2 short circuit circuit to power
to power

P2096- Post Catalyst Fuel Trim NOTE: Refer to the electrical


00 System Too Lean Bank 1 - circuit diagrams and
No sub type information - Circuit HEGO_SENSOR_A - check post catalyst
oxygen sensor - odd,
Post catalyst oxygen sensor odd, sensing circuit for short
sensing circuit short circuit to ground, circuit to ground, high
high resistance, open circuit resistance, open circuit
Air leak between catalyst and exhaust Check for air leak
manifold between catalyst and
Air leak between the two oxygen exhaust manifold
sensors Check for air leak
Post catalyst oxygen sensor odd, between the two oxygen
failure sensors
Check and install new
post catalyst oxygen
sensor odd, as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P2097- Post Catalyst Fuel Trim NOTE: Refer to the electrical


00 System Too Rich Bank 1 - circuit diagrams and
No sub type information - Circuit HEGO_SENSOR_A - check post catalyst
oxygen sensor - odd,
Post catalyst oxygen sensor odd, sensing circuit for short
sensing circuit short circuit to ground, circuit to ground, high
high resistance, open circuit resistance, open circuit
Air leak between catalyst and exhaust Check for air leak
manifold between catalyst and
Air leak between the two oxygen exhaust manifold
sensors Check for air leak
Post catalyst oxygen sensor odd, between the two oxygen
failure sensors
Check and install new
post catalyst oxygen
sensor odd, as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P2098- Post Catalyst Fuel Trim NOTE: Refer to the electrical


00 System Too Lean Bank 2 - circuit diagrams and
No sub type information - Circuit HEGO_SENSOR_B - check post catalyst
oxygen sensor even,
Post catalyst oxygen sensor even, sensing circuit for short
sensing circuit short circuit to ground, circuit to ground, high
high resistance, open circuit resistance, open circuit
Air leak between catalyst and exhaust Check for air leak
manifold between catalyst and
Air leak between the two oxygen exhaust manifold
sensors Check for air leak
Post catalyst oxygen sensor even, between the two oxygen
failure sensors
Check and install new
post catalyst oxygen
sensor even, as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P2099- Post Catalyst Fuel Trim NOTE: Refer to the electrical


00 System Too Rich Bank 2 - circuit diagrams and
No sub type information - Circuit HEGO_SENSOR_B - check post catalyst
oxygen sensor even,
Post catalyst oxygen sensor even, sensing circuit for short
sensing circuit short circuit to ground, circuit to ground, high
high resistance, open circuit resistance, open circuit
Air leak between catalyst and exhaust Check for air leak
manifold between catalyst and
Air leak between the two oxygen exhaust manifold
sensors Check for air leak
Post catalyst oxygen sensor even, between the two oxygen
failure sensors
Check and install new
post catalyst oxygen
sensor even, as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P2105- Throttle Actuator Control NOTE: Check for any DTCs


00 System - Forced Engine relating to engine
Shutdown - No sub type - Circuit THROTTLE_MOTOR_NEG - control module, throttle
information THROTTLE_MOTOR_POS - pedal position sensor, or
torque faults and refer
Engine speed or torque limitation has to the DTC index
been activated as a result of engine
control module, throttle pedal position
sensor, or torque faults

P2118- Throttle Actuator Control NOTE: Refer to the electrical


19 Motor Current circuit diagrams and
Range/Performance - - Circuit THROTTLE_MOTOR_NEG - check electronic throttle
Circuit current above THROTTLE_MOTOR_POS - unit circuit for short
threshold circuit to ground, short
Throttle motor control circuit short circuit to power, high
circuit to ground, short circuit to resistance
power, high resistance Refer to the electrical
Engine control module ground circuit circuit diagrams and
fault check engine control
Carbon build-up on throttle blade module ground circuit
Electronic throttle unit failure for faults
Make sure throttle blade
is clean of carbon
Check the system is
operating correctly and
the DTC does not return
Check and install a new
electronic throttle unit
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P2119- Throttle Actuator Control NOTE: Make sure throttle blade


00 Throttle Body is clean of carbon
Range/Performance - No - Circuit THROTTLE_MOTOR_NEG - Refer to the electrical
sub type information THROTTLE_MOTOR_POS - circuit diagrams and
check engine control
Carbon build-up on throttle blade module ground circuit
Engine control module ground circuit for faults
fault Check the system is
Electronic throttle unit return spring operating correctly and
faulty the DTC does not return
Electronic throttle unit limp home Check and install a new
spring faulty electronic throttle unit
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P2119- Throttle Actuator Control NOTE: Ensure throttle blade is


29 Throttle Body free of any carbon
Range/Performance - - Circuit THROTTLE_MOTOR_NEG - build-up / other
Signal invalid THROTTLE_MOTOR_POS - obstructions
Check the system is
Stuck / sticking throttle blade operating correctly and
Electronic throttle unit failure the DTC does not return
Check and install a new
electronic throttle unit
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P2119- Throttle Actuator Control NOTE: Ensure throttle blade is


64 Throttle Body free of any carbon
Range/Performance - - Circuit THROTTLE_MOTOR_NEG - build-up / other
Signal plausibility failure THROTTLE_MOTOR_POS - obstructions
Check the system is
Stuck / sticking throttle blade operating correctly and
Electronic throttle unit failure the DTC does not return
Check and install a new
electronic throttle unit
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P2122- Throttle/Pedal Position NOTE: Refer to the electrical


00 Sensor/Switch D Circuit circuit diagrams and
Low - No sub type - Circuit check accelerator pedal
information THROTTLE_POSITION_SENSOR_1 - unit, accelerator pedal
position sensor 1 circuit
Accelerator pedal position sensor 1
for short circuit to
circuit short circuit to ground, open ground, open circuit
circuit Check accelerator pedal
Accelerator pedal position sensor 1, unit, VREF circuit for
VREF circuit open circuit open circuit
Accelerator pedal position sensor 1 Clear DTC and repeat
failure automated diagnostic
procedure using the
manufacturer approved
diagnostic system
If DTC remains, check
and install a new
accelerator pedal unit as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P2123- Throttle/Pedal Position NOTE: Refer to the electrical


00 Sensor/Switch D Circuit circuit diagrams and
High - No sub type - Circuit check accelerator pedal
information THROTTLE_POSITION_SENSOR_1 - unit, accelerator pedal
position sensor 1 circuit
Accelerator pedal position sensor 1 for short circuit to
circuit short circuit to power power
Accelerator pedal position sensor 1, Check accelerator pedal
VREF circuit open circuit unit, VREF circuit for
Accelerator pedal position sensor 1 open circuit
failure Clear DTC and repeat
automated diagnostic
procedure using the
manufacturer approved
diagnostic system
If DTC remains, check
and install a new
accelerator pedal unit as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P2127- Throttle/Pedal Position NOTE: Refer to the electrical


00 Sensor/Switch E Circuit circuit diagrams and
Low - No sub type - Circuit check accelerator pedal
information THROTTLE_POSITION_SENSOR_2 - unit, accelerator pedal
position sensor 2 circuit
Accelerator pedal position sensor 2 for short circuit to
circuit short circuit to ground, open ground, open circuit
circuit Check accelerator pedal
Accelerator pedal position sensor 2, unit, VREF circuit for
VREF circuit open circuit open circuit
Accelerator pedal position sensor 2 Clear DTC and repeat
failure automated diagnostic
procedure using the
manufacturer approved
diagnostic system
If DTC remains, check
and install a new
accelerator pedal unit as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P2128- Throttle/Pedal Position NOTE: Refer to the electrical


00 Sensor/Switch E Circuit circuit diagrams and
High - No sub type - Circuit check accelerator pedal
information THROTTLE_POSITION_SENSOR_2 - unit, accelerator pedal
position sensor 2 circuit
Accelerator pedal position sensor 2 for short circuit to
circuit short circuit to power power
Accelerator pedal position sensor 2, Check accelerator pedal
VREF circuit open circuit unit, VREF circuit for
Accelerator pedal position sensor 2 open circuit
failure Clear DTC and repeat
automated diagnostic
procedure using the
manufacturer approved
diagnostic system
If DTC remains, check
and install a new
accelerator pedal unit as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P2135- Throttle/Pedal Position Throttle pedal position sensor circuit 1 Refer to the electrical
00 Sensor/Switch A / B and 2 short circuit to ground, short circuit diagrams and
Voltage Correlation - No circuit to power, open circuit check throttle pedal
sub type information position sensor circuit 1
and 2 for short circuit to
ground, short circuit to
power, open circuit

P2135- Throttle/Pedal Position Throttle pedal position sensor circuit 1 Refer to the electrical
09 Sensor/Switch A / B and 2 short circuit to ground, short circuit diagrams and
Voltage Correlation - circuit to power, open circuit check throttle pedal
Component Failures position sensor circuit 1
and 2 for short circuit to
ground, short circuit to
power, open circuit

P2138- Throttle/Pedal Position Accelerator pedal position sensor Refer to the electrical
64 Sensor/Switch D / E circuit 1 and 2 short circuit to ground, circuit diagrams and
Voltage Correlation - No short circuit to power, open circuit check accelerator pedal
sub type information position sensor circuit 1
and 2 for short circuit to
ground, short circuit to
power, open circuit

P2169- Exhaust Pressure Regulator NOTE: Refer to the electrical


13 Vent Solenoid Control circuit diagrams and
Circuit / Open - Circuit Jaguar - Circuit ACTIVE_EXT_VALVE - check active exhaust
open solenoid valve circuit
Active exhaust solenoid valve circuit for open circuit
open circuit

P2170- Exhaust Pressure Regulator NOTE: Refer to the electrical


11 Vent Solenoid Control circuit diagrams and
Circuit Low - Circuit short Jaguar - Circuit ACTIVE_EXT_VALVE - check active exhaust
to ground solenoid valve circuit
Active exhaust solenoid valve circuit for short circuit to
short circuit to ground ground

P2171- Exhaust Pressure Regulator NOTE: Refer to the electrical


12 Vent Solenoid Control circuit diagrams and
Circuit high - Circuit short Jaguar - Circuit ACTIVE_EXT_VALVE - check active exhaust
to battery solenoid valve circuit
Active exhaust solenoid valve circuit for short circuit to
short circuit to power power

P2183- Engine Coolant NOTE: Refer to the electrical


23 Temperature Sensor 2 circuit diagrams and
Circuit Range/Performance - Circuit COOLANT_TEMP_SENSOR_2 - check engine coolant
- Signal stuck low temperature sensor 2
Engine coolant temperature sensor 2 circuit for high
circuit high resistance, open circuit resistance, open circuit
Engine coolant temperature sensor 2 Check and install a new
failure engine coolant
temperature sensor 2 as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P2183- Engine Coolant NOTE: Refer to the electrical


24 Temperature Sensor 2 circuit diagrams and
Circuit Range/Performance - Circuit COOLANT_TEMP_SENSOR_2 - check engine coolant
- Signal stuck high temperature sensor 2
Engine coolant temperature sensor 2 circuit for short circuit
circuit short circuit to power to power
Engine coolant temperature sensor 2 Check and install a new
failure engine coolant
temperature sensor 2 as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P2183- Engine Coolant NOTE: Refer to the electrical


29 Temperature Sensor 2 circuit diagrams and
Circuit Range/Performance - Circuit COOLANT_TEMP_SENSOR_2 - check engine coolant
- Signal invalid temperature sensor 2
Engine coolant temperature sensor 2 circuit for high
circuit high resistance, open circuit, resistance, open circuit,
short circuit to ground, short circuit to short circuit to ground,
power short circuit to power
Engine coolant temperature sensor 2 Check and install a new
failure engine coolant
temperature sensor 2 as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P2184- Engine Coolant NOTE: Refer to the electrical


16 Temperature Sensor 2 circuit diagrams and
Circuit Low - Circuit - Circuit COOLANT_TEMP_SENSOR_2 - check engine coolant
voltage below threshold temperature sensor 2
Engine coolant temperature sensor 2 circuit for high
circuit high resistance, open circuit, resistance, open circuit,
short circuit to ground short circuit to ground
Engine coolant temperature sensor 2 Check and install a new
failure engine coolant
temperature sensor 2 as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P2185- Engine Coolant NOTE: Clear the DTC and re-


17 Temperature Sensor 2 test
Circuit High - Circuit - Circuit COOLANT_TEMP_SENSOR_2 - Refer to the electrical
voltage above threshold circuit diagrams and
Ignition turned on with an ambient check engine coolant
temperature of below -40c temperature sensor 2
Engine coolant temperature sensor 2 circuit for short circuit
circuit short circuit to power to power
Engine coolant temperature sensor 2 Check and install a new
failure engine coolant
temperature sensor 2 as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P219A- Bank 1 Air-Fuel Ratio NOTE: Using the manufacturer


00 Imbalance - No sub type approved diagnostic
information Post catalyst oxygen sensor-odd & Pre system check the engine
catalyst oxygen sensor-odd control module for
oxygen sensor related
Other oxygen sensor related DTCs DTCs and refer to the
Air leak in the exhaust system between relevant DTC index.
post catalyst oxygen sensor-odd and Record any available
catalyst freeze frame data
Air leak in the exhaust system between Check for air leaks in
catalyst and exhaust manifold flange the exhaust system
Air leak in the exhaust system between between post catalyst
pre catalyst oxygen sensor-odd and oxygen sensor-odd and
post catalyst oxygen sensor-odd catalyst
Air leak around pre catalyst oxygen Check for air leaks in
sensor-odd the exhaust system
Air leaks within the intake system between catalyst and
Air leak around fuel injector(s) bank 1 exhaust manifold flange
Air leak around spark plug(s) bank 1 Check for air leaks in
Low fuel pressure, fuel injector(s) leak, the exhaust system
fuel system leak bank 1 between pre catalyst
Camshaft position actuator sticking oxygen sensor-odd and
Airpath blockage between throttle post catalyst oxygen
butterfly and inlet poppet valve sensor-odd
Post catalyst oxygen sensor-odd failure Check for air leaks
Cylinder head gasket failure around pre catalyst
oxygen sensor-odd
Check for air leaks
within the intake system
Check for air leak
around fuel injector(s)
bank 1
Check for air leak
around spark plug(s)
bank 1
Check for low fuel
pressure, fuel injector(s)
leak, fuel system leak
bank 1
Check for camshaft
position actuator
sticking
Check for airpath
blockage between
throttle butterfly and
inlet poppet valve
Carry out cylinder
compression check.
Record the results
Check and install a post
catalyst oxygen sensor-
odd as required. Refer
to the warranty policy
and procedures manual,
or determine if any
prior approval
programme is in
operation, prior to the
installation of a new
module/component
Using the manufacturer
approved diagnostic
system clear DTC and
retest

P219B- Bank 2 Air-Fuel Ratio NOTE: Using the manufacturer


00 Imbalance - No sub type approved diagnostic
information Post catalyst oxygen sensor-even & Pre system check the engine
catalyst oxygen sensor-even control module for
oxygen sensor related
Other oxygen sensor related DTCs DTCs and refer to the
Air leak in the exhaust system between relevant DTC index.
post catalyst oxygen sensor-even and Record any available
catalyst freeze frame data
Air leak in the exhaust system between Check for air leaks in
catalyst and exhaust manifold flange the exhaust system
Air leak in the exhaust system between between post catalyst
pre catalyst oxygen sensor-even and oxygen sensor-even and
post catalyst oxygen sensor-even catalyst
Air leak around pre catalyst oxygen Check for air leaks in
sensor-even the exhaust system
Air leaks within the intake system between catalyst and
Air leak around fuel injector(s) bank 2 exhaust manifold flange
Air leak around spark plug(s) bank 2 Check for air leaks in
Low fuel pressure, fuel injector(s) leak, the exhaust system
fuel system leak bank 2 between pre catalyst
Camshaft position actuator sticking oxygen sensor-even and
Airpath blockage between throttle post catalyst oxygen
butterfly and inlet poppet valve sensor-even
Post catalyst oxygen sensor-even Check for air leaks
failure around pre catalyst
Cylinder head gasket failure oxygen sensor-even
Check for air leaks
within the intake system
Check for air leak
around fuel injector(s)
bank 2
Check for air leak
around spark plug(s)
bank 2
Check for low fuel
pressure, fuel injector(s)
leak, fuel system leak
bank 2
Check for camshaft
position actuator
sticking
Check for airpath
blockage between
throttle butterfly and
inlet poppet valve
Carry out cylinder
compression check.
Record the results
Check and install a post
catalyst oxygen sensor-
even as required. Refer
to the warranty policy
and procedures manual,
or determine if any
prior approval
programme is in
operation, prior to the
installation of a new
module/component
Using the manufacturer
approved diagnostic
system clear DTC and
retest

P2228- Barometric Pressure Barometric pressure sensor Using the manufacturer


00 Circuit Low - No sub type failure(internal engine control module approved diagnostic
information failure) system check
datalogger signal,
Barometric Pressure
Sensor Voltage
(0x035A)
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P2229- Barometric Pressure Barometric pressure sensor Using the manufacturer


00 Circuit Low - No sub type failure(internal engine control module approved diagnostic
information failure) system check
datalogger signal,
Barometric Pressure
Sensor Voltage
(0x035A)
Check and install a new
engine control module
as required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P2279- Intake Air System Leak - Part load breather pipe disconnected Check for related DTCs
00 No sub type information Brake vacuum pipe disconnected Check part load
Excessive intake air leak breather pipe for leaks
or disconnected
Check brake vacuum
pipe for leaks or
disconnected
Check intake air system
for leaks

P2300- Ignition Coil A Primary NOTE: Refer to the electrical


11 Control Circuit Low - circuit diagrams and
Circuit short to ground - Circuit IGNITION_1A - check ignition coil 1
circuit for short circuit
Ignition coil 1 circuit short circuit to to ground
ground

P2301- Ignition Coil A Primary NOTE: Refer to the electrical


12 Control Circuit High - circuit diagrams and
Circuit short to battery - Circuit IGNITION_1A - check ignition coil 1
circuit for short circuit
Ignition coil 1 circuit short circuit to to power
power

P2303- Ignition Coil B Primary NOTE: Refer to the electrical


11 Control Circuit Low - circuit diagrams and
Circuit short to ground - Circuit IGNITION_1B - check ignition coil 2
circuit for short circuit
Ignition coil 2 circuit short circuit to to ground
ground

P2304- Ignition Coil B Primary NOTE: Refer to the electrical


12 Control Circuit High - circuit diagrams and
Circuit short to battery - Circuit IGNITION_1B - check ignition coil 2
circuit for short circuit
Ignition coil 2 circuit short circuit to to power
power

P2306- Ignition Coil C Primary NOTE: Refer to the electrical


11 Control Circuit Low - circuit diagrams and
Circuit short to ground - Circuit IGNITION_2A - check ignition coil 3
circuit for short circuit
Ignition coil 3 circuit short circuit to to ground
ground
P2307- Ignition Coil C Primary NOTE: Refer to the electrical
12 Control Circuit High - circuit diagrams and
Circuit short to battery - Circuit IGNITION_2A - check ignition coil 3
circuit for short circuit
Ignition coil 3 circuit short circuit to to power
power

P2309- Ignition Coil D Primary NOTE: Refer to the electrical


11 Control Circuit Low - circuit diagrams and
Circuit short to ground - Circuit IGNITION_2B - check ignition coil 4
circuit for short circuit
Ignition coil 4 circuit short circuit to to ground
ground

P2310- Ignition Coil D Primary NOTE: Refer to the electrical


12 Control Circuit High - circuit diagrams and
Circuit short to battery - Circuit IGNITION_2B - check ignition coil 4
circuit for short circuit
Ignition coil 4 circuit short circuit to to power
power

P2312- Ignition Coil E Primary NOTE: Refer to the electrical


11 Control Circuit Low - circuit diagrams and
Circuit short to ground - Circuit IGNITION_3A - check ignition coil 5
circuit for short circuit
Ignition coil 5 circuit short circuit to to ground
ground

P2313- Ignition Coil E Primary NOTE: Refer to the electrical


12 Control Circuit High - circuit diagrams and
Circuit short to battery - Circuit IGNITION_3A - check ignition coil 5
circuit for short circuit
Ignition coil 5 circuit short circuit to to power
power

P2315- Ignition Coil F Primary NOTE: Refer to the electrical


11 Control Circuit Low - circuit diagrams and
Circuit short to ground - Circuit IGNITION_3B - check ignition coil 6
circuit for short circuit
Ignition coil 6 circuit short circuit to to ground
ground

P2316- Ignition Coil F Primary NOTE: Refer to the electrical


12 Control Circuit High - circuit diagrams and
Circuit short to battery - Circuit IGNITION_3B - check ignition coil 6
circuit for short circuit
Ignition coil 6 circuit short circuit to to power
power

P2318- Ignition Coil G Primary NOTE: Refer to the electrical


11 Control Circuit Low - circuit diagrams and
Circuit short to ground - Circuit IGNITION_4A - check ignition coil 7
circuit for short circuit
Ignition coil 7 circuit short circuit to to ground
ground

P2319- Ignition Coil G Primary NOTE: Refer to the electrical


12 Control Circuit High - circuit diagrams and
Circuit short to battery - Circuit IGNITION_4A - check ignition coil 7
circuit for short circuit
Ignition coil 7 circuit short circuit to to power
power

P2321- Ignition Coil H Primary NOTE: Refer to the electrical


11 Control Circuit Low - circuit diagrams and
Circuit short to ground - Circuit IGNITION_4B - check ignition coil 8
circuit for short circuit
Ignition coil 8 circuit short circuit to to ground
ground

P2322- Ignition Coil H Primary NOTE: Refer to the electrical


12 Control Circuit High - circuit diagrams and
Circuit short to battery - Circuit IGNITION_4B - check ignition coil 8
circuit for short circuit
Ignition coil 8 circuit short circuit to to power
power

P2401- Evaporative Emission Diagnostic module tank leakage pump NOTES:


00 System Leak Detection circuit short circuit to ground
Pump Control Circuit Low If purge valve related
- No sub type information DTCs are also set,
perform the relevant
corrective action(s)
first.

It is not possible to
replicate the failure
event as certain entry
conditions must be
satisfied (for more
information, refer to
section 303-13:
Evaporative Emissions /
Description and
Operation). To verify
the customer concern,
perform routine
Evaporative System
Diagnostic Check and
re-read DTCs.

Refer to the electrical


circuit diagrams and
check the diagnostic
module tank leakage
pump circuit for short
circuit to ground

P2402- Evaporative Emission Diagnostic module tank leakage pump NOTES:


00 System Leak Detection circuit short circuit to power
Pump Control Circuit High If purge valve related
- No sub type information DTCs are also set,
perform the relevant
corrective action(s)
first.
It is not possible to
replicate the failure
event as certain entry
conditions must be
satisfied (for more
information, refer to
section 303-13:
Evaporative Emissions /
Description and
Operation). To verify
the customer concern,
perform routine
Evaporative System
Diagnostic Check and
re-read DTCs.

Refer to the electrical


circuit diagrams and
check the diagnostic
module tank leakage
pump circuit for short
circuit to power

P2404- Evaporative Emission Diagnostic module tank leakage NOTES:


29 System Leak Detection module internal failure
Pump Sense Circuit Changeover valve fault If purge valve related
Range/Performance - DTCs are also set,
Signal invalid perform the relevant
corrective action(s)
first.

It is not possible to
replicate the failure
event as certain entry
conditions must be
satisfied (for more
information, refer to
section 303-13:
Evaporative Emissions /
Description and
Operation). To verify
the customer concern,
perform routine
Evaporative System
Diagnostic Check and
re-read DTCs.

Install a new diagnostic


module tank leakage
module as necessary

P2404- Evaporative Emission Diagnostic module tank leakage NOTES:


2F System Leak Detection module internal failure
Pump Sense Circuit Changeover valve fault If purge valve related
Range/Performance - DTCs are also set,
Signal erratic perform the relevant
corrective action(s)
first.

It is not possible to
replicate the failure
event as certain entry
conditions must be
satisfied (for more
information, refer to
section 303-13:
Evaporative Emissions /
Description and
Operation). To verify
the customer concern,
perform routine
Evaporative System
Diagnostic Check and
re-read DTCs.

Install a new diagnostic


module tank leakage
module as necessary

P2405- Evaporative Emission Diagnostic module tank leakage NOTES:


00 System Leak Detection module internal failure
Pump Sense Circuit Low - If purge valve related
No sub type information DTCs are also set,
perform the relevant
corrective action(s)
first.

It is not possible to
replicate the failure
event as certain entry
conditions must be
satisfied (for more
information, refer to
section 303-13:
Evaporative Emissions /
Description and
Operation). To verify
the customer concern,
perform routine
Evaporative System
Diagnostic Check and
re-read DTCs.

Install a new diagnostic


module tank leakage
module as necessary

P2406- Evaporative Emission Diagnostic module tank leakage NOTES:


00 System Leak Detection module internal failure
Pump Sense Circuit High - If purge valve related
No sub type information DTCs are also set,
perform the relevant
corrective action(s)
first.
It is not possible to
replicate the failure
event as certain entry
conditions must be
satisfied (for more
information, refer to
section 303-13:
Evaporative Emissions /
Description and
Operation). To verify
the customer concern,
perform routine
Evaporative System
Diagnostic Check and
re-read DTCs.

Install a new diagnostic


module tank leakage
module as necessary

P240A- Evaporative Emission Diagnostic module tank leakage heater NOTES:


00 System Leak Detection circuit open circuit, high resistance
Pump Heater Circuit/Open If purge valve related
- No sub type information DTCs are also set,
perform the relevant
corrective action(s)
first.

It is not possible to
replicate the failure
event as certain entry
conditions must be
satisfied (for more
information, refer to
section 303-13:
Evaporative Emissions /
Description and
Operation). To verify
the customer concern,
perform routine
Evaporative System
Diagnostic Check and
re-read DTCs.

Refer to the electrical


circuit diagrams and
check the diagnostic
module tank leakage
heater circuit for open
circuit, high resistance

P240B- Evaporative Emission Diagnostic module tank leakage heater NOTES:


00 System Leak Detection circuit short circuit to ground
Pump Heater Circuit Low - If purge valve related
No sub type information DTCs are also set,
perform the relevant
corrective action(s)
first.

It is not possible to
replicate the failure
event as certain entry
conditions must be
satisfied (for more
information, refer to
section 303-13:
Evaporative Emissions /
Description and
Operation). To verify
the customer concern,
perform routine
Evaporative System
Diagnostic Check and
re-read DTCs.

Refer to the electrical


circuit diagrams and
check the diagnostic
module tank leakage
heater circuit for short
circuit to ground

P240C- Evaporative Emission Diagnostic module tank leakage heater NOTES:


00 System Leak Detection circuit short circuit to power
Pump Heater Circuit High If purge valve related
- No sub type information DTCs are also set,
perform the relevant
corrective action(s)
first.

It is not possible to
replicate the failure
event as certain entry
conditions must be
satisfied (for more
information, refer to
section 303-13:
Evaporative Emissions /
Description and
Operation). To verify
the customer concern,
perform routine
Evaporative System
Diagnostic Check and
re-read DTCs.

Refer to the electrical


circuit diagrams and
check the diagnostic
module tank leakage
heater circuit for short
circuit to power

P2450- Evaporative Emission NOTES: Check and install a new


00 Control System Switching diagnostic module tank
Valve Performance/Stuck - Circuit COV - leakage as required.
Open - No sub type Refer to the warranty
information LR - Circuit CHANGE OVER policy and procedures
VALVE - manual, or determine if
any prior approval
Diagnostic module tank leakage failure programme is in
operation, prior to the
installation of a new
module/component

P2451- Evaporative Emission NOTES: Check and install a new


00 Control System Switching diagnostic module tank
Valve Performance/Stuck - Circuit COV - leakage as required.
Closed - No sub type Refer to the warranty
information LR - Circuit CHANGE OVER policy and procedures
VALVE - manual, or determine if
any prior approval
Diagnostic module tank leakage failure programme is in
operation, prior to the
installation of a new
module/component

P250C- Engine Oil Level Sensor NOTE: Using the manufacturer


23 Circuit Low - Signal stuck approved diagnostic
low - Circuit OIL_QUALITY_SENSOR - system check
datalogger signal, Sump
Oil temperature level sensor circuit Oil Temperature -
short circuit to ground Measured (0x03F3)
Oil temperature level sensor failure Refer to the electrical
circuit diagrams and
check oil temperature
level sensor circuit for
short circuit to ground
Check and install a new
oil temperature level
sensor as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P250D- Engine Oil Level Sensor NOTE: Using the manufacturer


24 Circuit High - Signal stuck approved diagnostic
high - Circuit OIL_QUALITY_SENSOR - system check
datalogger signal, Sump
Oil temperature level sensor circuit Oil Temperature -
short circuit to power Measured (0x03F3)
Oil temperature level sensor failure Refer to the electrical
circuit diagrams and
check oil temperature
level sensor circuit for
short circuit to power
Check and install a new
oil temperature level
sensor as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

P2544- Torque Management Inappropriate request from anti-lock Check for related DTCs
64 Request Input Signal A - braking system within anti-lock braking
Signal plausibility failure system module and
refer to the relevant
DTC index
Using the manufacturer
approved diagnostic
system, complete a
CAN network integrity
test

P2544- Torque Management Inappropriate request from anti-lock Check for related DTCs
92 Request Input Signal A - braking system within anti-lock braking
Performance or incorrect system module and
operation refer to the relevant
DTC index
Using the manufacturer
approved diagnostic
system, complete a
CAN network integrity
test

P2600- Coolant Pump A Control NOTE: Refer to the electrical


13 Circuit / Open - Circuit circuit diagrams and
open XF - Circuit IC_COOLANT_PMP_CTRL - check coolant pump A
XK - Circuit INT_WATERPUMP_RLY - control circuit for open
circuit
Coolant pump A control circuit open
circuit

P2601- Coolant Pump Control NOTE: Check coolant level and


00 Circuit Range/Performance top up as required
- No sub type information XF - Circuit IC_COOLANT_PMP_CTRL - Check the cooling
XK - Circuit INT_WATERPUMP_RLY - system for blockages or
trapped hoses
Coolant level low Refer to the electrical
Blocked cooling system circuit diagrams and
Coolant pump A control circuit open check coolant pump A
circuit control circuit for open
Coolant pump A failure circuit
Check and install a new
coolant pump A as
required. Refer to the
warranty policy and
procedures manual, or
determine if any prior
approval programme is
in operation, prior to the
installation of a new
module/component

P2602- Coolant Pump A Control NOTE: Refer to the electrical


11 Circuit Low - Circuit short circuit diagrams and
to ground XF - Circuit IC_COOLANT_PMP_CTRL - check coolant pump A
XK - Circuit INT_WATERPUMP_RLY - control circuit for short
circuit to ground
Coolant pump A control circuit short
circuit to ground

P2603- Coolant Pump A Control NOTE: Refer to the electrical


12 Circuit High - Circuit short circuit diagrams and
to battery XF - Circuit IC_COOLANT_PMP_CTRL - check coolant pump A
XK - Circuit INT_WATERPUMP_RLY - control circuit for short
circuit to power
Coolant pump A control circuit short
circuit to power

P2610- ECM/PCM Internal Engine Instrument cluster fault Check for DTCs related
00 Off Timer Performance - Central junction box fault to any of the
No sub type information CAN network error components listed and
refer to relevant DTC
index
Using the manufacturer
approved diagnostic
system, complete a
CAN network integrity
test

P2610- ECM/PCM Engine Off Instrument cluster fault Check for DTCs related
84 Timer Performance - Central junction box fault to any of the
Signal below allowable Engine coolant temperature sensor components listed and
range fault refer to relevant DTC
Ambient temperature sensor fault index
Low battery voltage Refer to the electrical
CAN network error circuit diagrams and
check engine coolant
temperature sensor
circuit for short circuit
to ground, short circuit
to power, open circuit
Refer to the electrical
circuit diagrams and
check ambient air
temperature sensor
circuit for short circuit
to ground, short circuit
to power, open circuit
Check the battery
voltage, repair as
required
Using the manufacturer
approved diagnostic
system, complete a
CAN network integrity
test

P2610- ECM/PCM Engine Off Instrument cluster fault Check for DTCs related
85 Timer Performance - Central junction box fault to any of the
Signal above allowable Engine coolant temperature sensor components listed and
range fault refer to relevant DTC
Ambient temperature sensor fault index
Low battery voltage Refer to the electrical
CAN network error circuit diagrams and
check engine coolant
temperature sensor
circuit for short circuit
to ground, short circuit
to power, open circuit
Refer to the electrical
circuit diagrams and
check ambient air
temperature sensor
circuit for short circuit
to ground, short circuit
to power, open circuit
Check the battery
voltage, repair as
required
Using the manufacturer
approved diagnostic
system, complete a
CAN network integrity
test

P2610- ECM/PCM Internal Engine Instrument cluster fault Check for DTCs related
87 Off Timer Performance - Central junction box fault to any of the
Missing message Engine coolant temperature sensor components listed, and
fault refer to relevant DTC
Ambient temperature sensor fault index
CAN network error Refer to the electrical
circuit diagrams and
check engine coolant
temperature sensor
circuit for short circuit
to ground, short circuit
to power, open circuit
Refer to the electrical
circuit diagrams and
check ambient air
temperature sensor
circuit for short circuit
to ground, short circuit
to power, open circuit
Using the manufacturer
approved diagnostic
system, complete a
CAN network integrity
test
U0001- High Speed CAN NOTE: Refer to the electrical
88 Communication Bus - Bus circuit diagrams and
off - Circuit HS_CAN_NEG - HS_CAN_POS - check CAN network for
short circuit to ground,
High speed CAN bus circuit, short short circuit to power,
circuit to ground open circuit
High speed CAN bus circuit, short Using the manufacturer
circuit to power approved diagnostic
High speed CAN bus, open circuit system, carry out
network integrity test

U0101- Lost Communication with CAN link engine control Using the manufacturer
00 TCM - No sub type module/transmission control module approved diagnostic
information network malfunction system, check
Transmission control module failure transmission control
module for DTCs and
refer to the relevant
DTC index
Using the manufacturer
approved diagnostic
system, complete a
CAN network integrity
test
Refer to the electrical
circuit diagrams and
check transmission
control module power
and ground circuit for
open circuit
Check CAN harness to
transmission control
module, repair as
necessary

U0103- Lost Communication with CAN link engine control module/gear Refer to the electrical
00 Gear Shift Control Module shift module network malfunction wiring diagrams and
A - No sub type check power and
information ground connections to
the gear shift module
Using the manufacturer
approved diagnostic
system, complete a
CAN network integrity
test

U0104- Lost Communication With Vehicle configured for speed control, Check vehicle has
00 Cruise Control Module - but speed control module is not correct speed control
No sub type information installed module installed
CAN Link engine control Using the manufacturer
module/speed control module network approved diagnostic
malfunction system, check speed
Speed control module power or ground control module, anti-
circuit, open circuit lock braking system
module for DTCs and
refer to the relevant
DTC index
Using the manufacturer
approved diagnostic
system, complete a
CAN network integrity
test
Refer to the electrical
circuit diagrams and
check speed control
module power and
ground circuit for open
circuit
Check CAN harness to
speed control module,
repair as necessary

U0121- Lost Communication With CAN Link engine control module/anti- Using the manufacturer
00 Anti-lock Braking System lock braking system module network approved diagnostic
(ABS) Control Module - malfunction system, check anti-lock
No sub type information Anti-lock braking system module braking system module
power or ground circuit, open circuit for DTCs and refer to
the relevant DTC index
Using the manufacturer
approved diagnostic
system, complete a
CAN network integrity
test
Refer to the electrical
circuit diagrams and
check anti-lock braking
system module power
and ground circuit for
open circuit
Check CAN harness to
anti-lock braking
system module, repair
as necessary

U0128- Lost Communication With CAN Link engine control Refer to the electrical
00 Park Brake Control module/electronic parking brake signal circuit diagrams and
Module - No sub type missing network malfunction check power and
information ground supplies to
electronic parking brake
Using the manufacturer
approved diagnostic
system, complete a
CAN network integrity
test

U0132- Lost Communication with CAN link/suspension control module Refer to the electrical
00 Suspension Control network malfunction circuit diagrams and
Module A - No sub type check power and
information ground supplies to
suspension control
module
Using the manufacturer
approved diagnostic
system, complete a
CAN network integrity
test

U0151- Lost Communication with Lost communication with restraints Refer to the electrical
00 Restraints Control Module control module over CAN or circuit diagrams and
- No sub type information hardwired link check power and
ground supplies to
restraints control
module
Using the manufacturer
approved diagnostic
system, complete a
CAN network integrity
test

U0151- Lost Communication with Lost communication due to restraints Check restraints control
87 Restraints Control Module control module fault module for associated
- Missing message DTCs and refer to
relevant DTC index
Refer to the electrical
circuit diagrams and
check power and
ground supplies to
restraints control
module
Using the manufacturer
approved diagnostic
system, complete a
CAN network integrity
test

U0155- Lost Communication with CAN link between engine control Refer to the electrical
00 Instrument Panel Cluster module and instrument cluster fault circuit diagrams and
(IPC) - No sub type check power and
information ground supplies to
instrument cluster
Using the manufacturer
approved diagnostic
system, complete a
CAN network integrity
test

U0167- Lost Communication with Security challenge response timeout Refer to the electrical
00 Vehicle Immobilizer Battery fault circuit diagrams and
Control Module - No sub check power and
type information ground supplies to the
electric steering column
lock
Check for related CAN
DTCs and refer to the
relevant DTC index
Ensure the battery is in
a fully charged and
serviceable condition.
Refer to the battery care
manual and the relevant
sections of the
workshop manual
Using the manufacturer
approved diagnostic
system, complete a
CAN network integrity
test

U0300- Internal Control Module Engine control module has incorrect Check and install the
00 Software Incompatibility - software installed correct engine control
No sub type information The engine control module is in module software
expulsion mode. An incorrect Check and install the
specification engine control module correct engine control
has been installed to the vehicle module as required.
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

U0402- Invalid Data Received Transmission engine control module Using the manufacturer
00 From Transmission request corruption approved diagnostic
Control Module - No sub system, check
type information transmission control
module, for DTCs and
refer to the relevant
DTC index
Using the manufacturer
approved diagnostic
system, complete a
CAN network integrity
test
Refer to the electrical
circuit diagrams and
check high speed CAN
bus circuit for short
circuit, open circuit

U0402- Invalid Data Received Transmission engine control module Using the manufacturer
08 from TCM - Bus signal / request corruption approved diagnostic
message failures High speed CAN bus circuit failure, system, check
short, open circuit transmission control
module, for DTCs and
refer to the relevant
DTC index
Using the manufacturer
approved diagnostic
system, complete a
CAN network integrity
test
Refer to the electrical
circuit diagrams and
check high speed CAN
bus circuit for short
circuit, open circuit
U0402- Invalid Data Received Transmission to engine control module Using the manufacturer
64 from TCM - Signal request corruption approved diagnostic
plausibility failure High speed CAN bus signal corruption system, check
transmission control
module, for DTCs and
refer to the relevant
DTC index
Using the manufacturer
approved diagnostic
system, complete a
CAN network integrity
test
Refer to the electrical
circuit diagrams and
check high speed CAN
bus circuit for short
circuit, open circuit

U0402- Invalid Data Received Transmission control module shaft- Using the manufacturer
82 from TCM - Alive / speed faults approved diagnostic
sequence counter incorrect system, check
/ not updated transmission control
module, for DTCs and
refer to the relevant
DTC index

U0402- Invalid Data Received Transmission control module shaft- Using the manufacturer
83 from TCM - Value of speed faults approved diagnostic
signal protection system, check
calculation incorrect transmission control
module, for DTCs and
refer to the relevant
DTC index

U0415- Invalid Data Received Electronic throttle unit, throttle Using the manufacturer
00 From Anti-lock Braking position sensor 1 failure approved diagnostic
System (ABS) Control Electronic throttle unit, throttle system, check for
Module - No sub type position sensor 2 failure electronic throttle unit
information Electronic throttle unit harness short, DTCs repair as
open circuit necessary
Refer to the electrical
circuit diagrams and
check electronic unit
harness for short circuit,
open circuit
Refer to the warranty
policy and procedures
manual, or determine if
any prior approval
programme is in
operation, prior to the
installation of a new
module/component

U0415- Invalid Data Received Invalid request from anti-lock braking Using the manufacturer
64 From Anti-lock Braking system approved diagnostic
System (ABS) Control Torque up request higher than system, check anti-lock
Module - Signal expected from anti-lock braking braking system, for
plausibility failure system DTCs and refer to the
relevant DTC index
Refer to the electrical
circuit diagrams and
check high speed CAN
bus circuit for short
circuit, open circuit

U0415- Invalid Data Received Torque up request higher than Using the manufacturer
67 From Anti-lock Braking expected from anti-lock braking approved diagnostic
System (ABS) Control system system, check anti-lock
Module - Signal incorrect braking system, for
after event DTCs and refer to the
relevant DTC index
Refer to the electrical
circuit diagrams and
check high speed CAN
bus circuit for short
circuit, open circuit

U0426- Invalid Data Received Security code mis-match Check CAN network
00 From Vehicle Immobilizer This DTC will be logged if the between engine control
Control Module - No sub encrypted data exchange does not module, instrument
type information match between engine control module cluster and central
and the instrument cluster or central junction box
junction box Refer to the electrical
circuit diagrams and
check power and
ground circuit to engine
control module and
instrument cluster
Check correct engine
control module and
instrument cluster
installed
Re-synchronise ID by
re-configuring the
engine control module
and instrument cluster
as new modules

U0447- Invalid Data Received The LIN to high speed CAN gateway This DTC has been
81 From Gateway "A" - has informed the engine control inhibited in the engine
Invalid serial data received module of a failure control module, as the
LIN bus flag is set
during normal operation
Published: 08-May-2019

2012.0 XF (X250), 100-00

General Information

Diagnostic Trouble Code Index - TDV6 3.0L Diesel ,


DTC: Engine Control Module (ECM) (G2046511)
DESCRIPTION AND OPERATION
Engine Control Module (ECM) - 3.0L Diesel
CAUTION:

Diagnosis by substitution from a donor vehicle is NOT acceptable. Substitution of control modules does not
guarantee confirmation of a fault and may also cause additional faults in the vehicle being tested and/or the donor
vehicle.

NOTES:

If a control module or a component is suspect and the vehicle remains under manufacturer warranty, refer to
the Warranty Policy and Procedures manual, or determine if any prior approval programme is in operation,
prior to the installation of a new module/component.

Generic scan tools may not read the codes listed, or may read only 5-digit codes. Match the 5 digits from the
scan tool to the first 5 digits of the 7-digit code listed to identify the fault (the last 2 digits give extra
information read by the manufacturer-approved diagnostic system).

When performing voltage or resistance tests, always use a digital multimeter accurate to three decimal places
and with an up-to-date calibration certificate. When testing resistance always take the resistance of the digital
multimeter leads into account.

Check and rectify basic faults before beginning diagnostic routines involving pinpoint tests.

Inspect connectors for signs of water ingress and pins for damage and/or corrosion.

If DTCs are recorded and, after performing the pinpoint tests, a fault is not present, an intermittent concern
may be the cause. Always check for loose connections and corroded terminals.

Check DDW for open campaigns. Refer to the corresponding bulletins and SSMs which may be valid for the
specific customer complaint and carry out the recommendations as required.

The table below lists all Diagnostic Trouble Codes (DTCs) that could be logged in the Engine Control Module
(ECM) - 3.0L Diesel. For additional diagnosis and testing information, refer to the relevant Diagnosis and Testing
section in the workshop manual. For additional information, refer to: Electronic Engine Controls (303-14A
Electronic Engine Controls - TDV6 3.0L Diesel, Diagnosis and Testing).

DTC Description Possible Causes Action


B1087- LIN Bus "A" - No Generator LIN bus Refer to the electrical circuit diagrams
93 operation communication circuit and check the generator LIN bus circuit,
failure for short circuit to power, short circuit
to ground, open circuit. Repair harness
as required. Using the Jaguar Land
Rover approved diagnostic system, clear
all stored DTCs using the ‘Diagnosis
Menu’ tab and retest

B10A2- Crash Input - Signal low Restraints control This DTC is set when the 'airbag
32 time < minimum module failure deployed' signal supplied by the
Auxiliary junction box restraints control module is outside the
failure specification expected by the engine
Harness failure control module
Check the restraints control module for
DTCs and refer to the relevant DTC
index
Check auxiliary junction box for DTCs
and refer to the relevant DTC index
Refer to electrical circuit diagrams and
check the supplementary restraints
system input circuit for failures. This
circuit is a single wire which connects
the restraints control module to the
auxiliary junction box and the engine
control module. Check this circuit for
short circuit to power, short circuit to
ground, open circuit. Repair harness as
required. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest

B10A2- Crash Input - Signal high Restraints control This DTC is set when the 'airbag
35 time > maximum module failure deployed' signal supplied by the
Auxiliary junction box restraints control module is outside the
failure specification expected by the engine
Harness failure control module
Check the restraints control module for
DTCs and refer to the relevant DTC
index
Check auxiliary junction box for DTCs
and refer to the relevant DTC index
Refer to electrical circuit diagrams and
check the supplementary restraints
system input circuit for failures. This
circuit is a single wire which connects
the restraints control module to the
auxiliary junction box and the engine
control module. Check this circuit for
short circuit to power, short circuit to
ground, open circuit. Repair harness as
required. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest

B10A2- Crash Input - Signal The engine control This DTC is set when the 'airbag
36 frequency too low module detected deployed' signal supplied by the
excessive duration for restraints control module is outside the
one cycle of the output specification expected by the engine
across a specified control module
sample size Check the restraints control module for
Restraints control DTCs and refer to the relevant DTC
module failure index
Auxiliary junction box Check auxiliary junction box for DTCs
failure and refer to the relevant DTC index
Harness failure Refer to electrical circuit diagrams and
check the supplementary restraints
system input circuit for failures. This
circuit is a single wire which connects
the restraints control module to the
auxiliary junction box and the engine
control module. Check this circuit for
short circuit to power, short circuit to
ground, open circuit. Repair harness as
required. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest

B10A2- Crash Input - Signal The engine control This DTC is set when the 'airbag
37 frequency too high module detected deployed' signal supplied by the
insufficient duration restraints control module is outside the
for one cycle of the specification expected by the engine
output across a control module
specified sample size Check the restraints control module for
Restraints control DTCs and refer to the relevant DTC
module failure index
Auxiliary junction box Check auxiliary junction box for DTCs
failure and refer to the relevant DTC index
Harness failure Refer to electrical circuit diagrams and
check the supplementary restraints
system input circuit for failures. This
circuit is a single wire which connects
the restraints control module to the
auxiliary junction box and the engine
control module. Check this circuit for
short circuit to power, short circuit to
ground, open circuit. Repair harness as
required. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest

B11D9- Vehicle Battery - No sub Harness failure This DTC is set when the battery
00 type information Battery failure monitoring system fails a diagnostic
Battery monitoring check
system module failure Refer to the battery care manual and
verify that the vehicle battery is fully
charged and serviceable before
continuing with further diagnostic tests
Refer to the electrical circuit diagrams
and check the connections between the
battery and the battery monitoring
module are clean and secure
Ensure that full battery voltage is
present on the monitor line pin at the
battery monitoring system module
connector. Ensure the battery ground
connection is clean and secure
Check the LIN bus connections to the
battery monitoring system module.
Check LIN bus integrity. Check and
install new battery monitoring system
module as required

B11DB- Battery Monitoring Harness failure This DTC is set when the engine control
87 Module - Missing message Battery monitoring module has lost communication with the
system module failure battery monitoring system module
Refer to the battery care manual and
verify that the vehicle battery is fully
charged and serviceable before
continuing with further diagnostic tests
Refer to the electrical circuit diagrams
and check the connections between the
battery and the battery monitoring
module are clean and secure
Ensure that full battery voltage is
present on the monitor line pin at the
battery monitoring system module
connector. Ensure the battery ground
connection is clean and secure
Check the LIN bus connections to the
battery monitoring system module.
Check LIN bus integrity. Check and
install new battery monitoring system
module as required

B1206- Crash Occurred - Event Event information - This DTC is set if the restraints control
68 information The engine control module has deployed the restraints
module has received a systems following activation of the
crash signal from the crash sensors. Check the restraints
restraints control control module for DTCs and refer to
module the relevant DTC index

P0030- HO2S Heater Control The engine control Using the Jaguar Land Rover approved
11 Circuit (Bank 1, Sensor 1) module has detected a diagnostic system, check datalogger
- Circuit short to ground ground measurement signals, Oxygen Sensor (O2S) Heater
for a period longer Duty Cycle Bank 1 Sensor 1 (0x03A1).
than expected or has Refer to the electrical circuit diagrams
detected a ground and check the heated oxygen sensor
measurement when heater control (heater ground) circuit for
another value was short circuit to ground. Repair harness
expected as required. Using the Jaguar Land
Harness failure - Rover approved diagnostic system, clear
Heated oxygen sensor all stored DTCs using the ‘Diagnosis
heater control circuit Menu’ tab and retest
short circuit to ground Check and install new heated oxygen
Heated oxygen sensor sensor as required
failure

P0030- HO2S Heater Control The engine control Using the Jaguar Land Rover approved
12 Circuit (Bank 1, Sensor 1) module has detected a diagnostic system, check datalogger
- Circuit short to battery vehicle power signals, Oxygen Sensor (O2S) Heater
measurement for a Duty Cycle Bank 1 Sensor 1 (0x03A1).
period longer than Refer to the electrical circuit diagrams
expected or has and check the heated oxygen sensor
detected a vehicle heater control (heater ground) circuit for
power measurement short circuit to power. Repair harness as
when another value required. Using the Jaguar Land Rover
was expected approved diagnostic system, clear all
Harness failure - stored DTCs using the ‘Diagnosis
Heated oxygen sensor Menu’ tab and retest
heater control circuit Check and install new heated oxygen
short circuit to power sensor as required
Heated oxygen sensor
failure

P0030- HO2S Heater Control The engine control Using the Jaguar Land Rover approved
13 Circuit (Bank 1, Sensor 1) module has diagnostic system, check datalogger
- Circuit open determined an open signals, Oxygen Sensor (O2S) Heater
circuit via lack of bias Duty Cycle Bank 1 Sensor 1 (0x03A1).
voltage, low current Refer to the electrical circuit diagrams
flow, no change in the and check the heated oxygen sensor
state of an input in heater control (heater ground) circuit for
response to an output open circuit. Repair harness as required.
Harness failure - Using the Jaguar Land Rover approved
Heated oxygen sensor diagnostic system, clear all stored DTCs
heater control circuit using the ‘Diagnosis Menu’ tab and
open circuit retest
Heated oxygen sensor Check and install new heated oxygen
failure sensor as required

P0030- HO2S Heater Control Harness failure - Using the Jaguar Land Rover approved
4B Circuit (Bank 1, Sensor 1) Heated oxygen sensor diagnostic system, check datalogger
- Over temperature heater control circuit signals, Oxygen Sensor (O2S) Heater
short circuit to power Duty Cycle Bank 1 Sensor 1 (0x03A1).
Heated oxygen sensor Refer to the electrical circuit diagrams
failure and check the heated oxygen sensor
heater control (heater ground) circuit for
short circuit to power. Repair harness as
required. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Check and install new heated oxygen
sensor as required

P0033- Turbocharger/Supercharger Harness failure - Boost Refer to the electrical circuit diagrams
00 Bypass Valve Control air recirculation and check the boost air recirculation
Circuit /Open - No sub solenoid control solenoid control circuit between the
type information circuit open circuit engine control module and the control
Boost air recirculation valve for open circuit. Check the power
solenoid failure supply to the control valve. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new boost air
recirculation solenoid as required

P0034- Turbocharger/Supercharger Harness failure - Boost Refer to the electrical circuit diagrams
00 Bypass Valve Control air recirculation and check the boost air recirculation
Circuit Low - No sub type solenoid circuit short solenoid circuit between the engine
information circuit to ground control module and the control valve for
Boost air recirculation a short circuit to ground. Check the
solenoid failure power supply to the control valve.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new boost air
recirculation solenoid as required

P0035- Turbocharger/Supercharger Harness failure - Boost Refer to the electrical circuit diagrams
00 Bypass Valve Control air recirculation and check the boost air recirculation
Circuit High - No sub type solenoid circuit short solenoid circuit between the engine
information circuit to power control module and the control valve for
Boost air recirculation a short circuit to power. Check the
solenoid failure power supply to the control valve.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new boost air
recirculation solenoid as required

P0039- Turbocharger/Supercharger Harness failure - Boost Refer to the electrical circuit diagrams
4B Bypass Valve Control air recirculation and check the boost air recirculation
Circuit Range/Performance solenoid circuit short solenoid circuit between the engine
- Over temperature to ground, short circuit control module and the control valve for
to power, high a short circuit to ground, short circuit to
resistance power, high resistance. Check the power
Boost air recirculation supply to the control valve. Repair
solenoid failure harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new boost air
recirculation solenoid as required

P004A- Turbocharger/Supercharger Harness failure - Using the Jaguar Land Rover approved
00 Boost Control B Circuit Variable geometry diagnostic system, check datalogger
/Open - No sub type turbine vane actuator signals, Commanded Boost Actuator
information control circuit open Control Bank 2 (0x0533), Boost
circuit Pressure Actuator Bank 2 - Controller
Variable geometry output (0x03DE). Refer to the electrical
turbine vane actuator circuit diagrams and check the variable
control unit failure geometry turbine vane actuator control
circuit for open circuit. Check both of
the circuits for open circuit. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Turbocharger
Check and install new variable
geometry turbine vane actuator control
unit as required

P004A- Turbocharger/Supercharger Harness failure - Using the Jaguar Land Rover approved
71 Boost Control B Circuit Variable geometry diagnostic system, check datalogger
/Open - Actuator stuck turbine vane actuator signals, Commanded Boost Actuator
control circuit open Control Bank 2 (0x0533), Boost
circuit Pressure Actuator Bank 2 - Controller
Variable geometry output (0x03DE). Refer to the electrical
turbine vane actuator circuit diagrams and check the variable
control unit failure geometry turbine vane actuator control
circuit for open circuit. Check both of
the circuits for open circuit. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new variable
geometry turbine vane actuator control
unit as required

P004B- Turbocharger/Supercharger The engine control Using the Jaguar Land Rover approved
16 Boost Control B Circuit module measured a diagnostic system, check datalogger
Range/Performance - voltage below a signals, Commanded Boost Actuator
Circuit voltage below specified range but not Control Bank 2 (0x0533). Refer to the
threshold necessarily a short electrical circuit diagrams and check the
circuit to ground variable geometry turbine vane actuator
Harness failure - control circuit for high resistance or
Variable geometry short circuit to another circuit. Check
turbine vane actuator both of the circuits for failures. Repair
control circuit harness as required. Using the Jaguar
Variable geometry Land Rover approved diagnostic
turbine vane actuator system, clear all stored DTCs using the
control unit failure ‘Diagnosis Menu’ tab and retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Turbocharger
Check and install new variable
geometry turbine vane actuator control
unit as required

P004B- Turbocharger/Supercharger Harness failure - Using the Jaguar Land Rover approved
19 Boost Control B Circuit Variable geometry diagnostic system, check datalogger
Range/Performance - turbine vane actuator signals, Commanded Boost Actuator
Circuit current above control circuit short Control Bank 2 (0x0533). Refer to the
threshold circuit to ground, short electrical circuit diagrams and check the
circuit to power, high variable geometry turbine vane actuator
resistance control circuit for short circuit to
Variable geometry ground, short circuit to power, high
turbine vane actuator resistance. Check both of the circuits for
control unit failure failures. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Turbocharger
Check and install new variable
geometry turbine vane actuator control
unit as required

P004B- Turbocharger/Supercharger Harness failure - Using the Jaguar Land Rover approved
1D Boost Control B Circuit Variable geometry diagnostic system, check datalogger
Range/Performance - turbine vane actuator signals, Commanded Boost Actuator
Circuit current out of range control circuit Control Bank 2 (0x0533). Refer to the
Mechanical failure on electrical circuit diagrams and check the
actuator mechanism variable geometry turbine vane actuator
Variable geometry control circuit for short circuit to
turbine vane actuator another circuit. Check both of the
control unit failure circuits for failures. Repair harness as
required. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Turbocharger
Check for mechanical failure on
actuator mechanism
Check and install new variable
geometry turbine vane actuator control
unit as required

P004B- Turbocharger/Supercharger Harness failure - Using the Jaguar Land Rover approved
4B Boost Control B Circuit Variable geometry diagnostic system, check datalogger
Range/Performance - Over turbine vane actuator signals, Commanded Boost Actuator
temperature control circuit short Control Bank 2 (0x0533). Refer to the
circuit to ground, short electrical circuit diagrams and check the
circuit to power, high variable geometry turbine vane actuator
resistance. control circuit for short circuit to
Mechanical failure on ground, short circuit to power, high
actuator mechanism resistance. Check both of the circuits for
Variable geometry failures. Repair harness as required.
turbine vane actuator Using the Jaguar Land Rover approved
control unit failure diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Turbocharger
Check for mechanical failure on
actuator mechanism
Check and install new variable
geometry turbine vane actuator control
unit as required

P004C- Turbocharger/Supercharger Harness failure - Using the Jaguar Land Rover approved
00 Boost Control B Circuit Variable geometry diagnostic system, check datalogger
Low - No sub type turbine vane actuator signals, Commanded Boost Actuator
information control circuit short Control Bank 2 (0x0533). Refer to the
circuit to ground electrical circuit diagrams and check the
variable geometry turbine vane actuator
control circuit for short circuit to
ground. Check both of the circuits for
failures. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Turbocharger

P004C- Turbocharger/Supercharger The engine control Using the Jaguar Land Rover approved
11 Boost Control B Circuit module has detected a diagnostic system, check datalogger
Low - Circuit short to ground measurement signals, Commanded Boost Actuator
ground for a period longer Control Bank 2 (0x0533). Refer to the
than expected or has electrical circuit diagrams and check the
detected a ground variable geometry turbine vane actuator
measurement when control circuit for short circuit to
another value was ground. Check both of the circuits for
expected failures. Repair harness as required.
Harness failure - Using the Jaguar Land Rover approved
Variable geometry diagnostic system, clear all stored DTCs
turbine vane actuator using the ‘Diagnosis Menu’ tab and
control circuit short retest
circuit to ground Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Turbocharger

P004C- Turbocharger/Supercharger The engine control Using the Jaguar Land Rover approved
12 Boost Control B Circuit module has detected a diagnostic system, check datalogger
Low circuit - Short to vehicle power signals, Commanded Boost Actuator
battery measurement for a Control Bank 2 (0x0533). Refer to the
period longer than electrical circuit diagrams and check the
expected or has variable geometry turbine vane actuator
detected a vehicle control circuit for short circuit to power.
power measurement Check both circuits for failures. Repair
when another value harness as required. Using the Jaguar
was expected Land Rover approved diagnostic
Harness failure - system, clear all stored DTCs using the
Variable geometry ‘Diagnosis Menu’ tab and retest
turbine vane actuator Using the Jaguar Land Rover approved
control circuit short diagnostic system, perform routine -
circuit to power Inline diagnostic unit 2 diagnostic test -
Turbocharger

P004C- Turbocharger/Supercharger Harness failure - Using the Jaguar Land Rover approved
77 Boost Control B Circuit Variable geometry diagnostic system, check datalogger
Low - Commanded turbine vane actuator signals, Commanded Boost Actuator
position not reachable control circuit short Control Bank 2 (0x0533). Refer to the
circuit to ground, high electrical circuit diagrams and check the
resistance, open circuit variable geometry turbine vane actuator
Harness failure - control circuit for short circuit to
Variable geometry ground, high resistance, open circuit.
turbocharger sensor Repair harness as required. Using the
circuit, short circuit to Jaguar Land Rover approved diagnostic
ground, high system, clear all stored DTCs using the
resistance, open circuit ‘Diagnosis Menu’ tab and retest
Mechanical failure on Refer to the electrical circuit diagrams
actuator mechanism and check the variable geometry
Variable geometry turbocharger sensor circuit for short
turbine vane actuator circuit to ground, high resistance, open
control unit failure circuit
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Turbocharger
Check for mechanical failure on
actuator mechanism
Check and install new variable
geometry turbine vane actuator control
unit as required

P004D- Turbocharger/Supercharger Harness failure - Using the Jaguar Land Rover approved
00 Boost Control B Circuit Variable geometry diagnostic system, check datalogger
High - No sub type turbine vane actuator signals, Commanded Boost Actuator
information control circuit short Control Bank 2 (0x0533). Refer to the
circuit to power electrical circuit diagrams and check the
boost control circuit for short circuit to
power. Check both circuits for failures.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Turbocharger

P004D- Turbocharger/Supercharger Harness failure - Using the Jaguar Land Rover approved
77 Boost Control B Circuit Variable geometry diagnostic system, check datalogger
High - Commanded turbine vane actuator signals, Commanded Boost Actuator
Position Not Reachable control circuit short Control Bank 2 (0x0533). Refer to the
circuit to power electrical circuit diagrams and check the
Harness failure - variable geometry turbine vane actuator
Variable geometry control circuit for short circuit to power.
turbocharger sensor Repair harness as required. Using the
circuit, short circuit to Jaguar Land Rover approved diagnostic
power system, clear all stored DTCs using the
Mechanical failure on ‘Diagnosis Menu’ tab and retest
actuator mechanism Refer to the electrical circuit diagrams
Variable geometry and check the variable geometry
turbine vane actuator turbocharger sensor circuit for short
control unit failure circuit to power
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Turbocharger
Check for mechanical failure on
actuator mechanism
Check and install new variable
geometry turbine vane actuator control
unit as required

P006A- MAP - Mass or Volume Intake air system, high If this DTC is logged with P1247-00,
00 Air Flow Correlation - No pressure boost leak P0402-00 & P00BF-07, suspect intake
sub type information bank 1 air system, high pressure boost leak
Intake air system, high bank 1
pressure boost leak bi- If this DTC is logged with P1247-00,
turbo mode bank 2 suspect intake air system, high pressure
Intake air system, low boost leak bi-turbo mode bank 2
pressure boost leak If this DTC is logged with P00BE-07 &
bank 1 P0401-00, suspect intake air system,
Intake air system, low low pressure boost leak bank 1
pressure boost leak If this DTC is logged with P00BC-00,
bank 2 suspect intake air system, low pressure
boost leak bank 2
Using the Jaguar Land Rover approved
diagnostic system, perform the (Turbo,
EGR and air path dynamic test) routine

P006A- MAP - Mass or Volume The engine control Check for other DTCs associated with
22 Air Flow Correlation - module measured a intake and boost air flow control
Signal amplitude > signal voltage above a actuators, refer to the relevant DTC
maximum specified range but not index and act on those DTCs first
necessarily a short Refer to workshop manual and check
circuit to power, gain intake air circuit, boost air circuit and
too high associated control valves, intercooler
Error path indicating and air filter for leaks, blockages,
whether over boost restrictions and control valve actuator
monitoring is active or malfunctions
not Refer to the electrical circuit diagrams
Failure in induction air and check both mass air flow sensor
circuit circuits for short circuit to ground, short
Failure in boost air circuit to power, high resistance, open
circuit circuit. Repair harness as required.
Mass air flow sensor Using the Jaguar Land Rover approved
circuit short circuit to diagnostic system, clear all stored DTCs
ground, short circuit to using the ‘Diagnosis Menu’ tab and
power, high resistance, retest
open circuit Check manifold absolute pressure
Manifold absolute sensor wiring circuits for short circuit to
pressure sensor circuit ground, short circuit to power, high
short circuit to ground, resistance, open circuit. Repair harness
short circuit to power, as required. Using the Jaguar Land
high resistance, open Rover approved diagnostic system, clear
circuit all stored DTCs using the ‘Diagnosis
Mass air flow sensor Menu’ tab and retest
failure Check and install new mass air flow
Manifold absolute sensor or manifold absolute pressure
pressure sensor failure sensor as required

P0070- Ambient Air Temperature The engine control Using the Jaguar Land Rover approved
16 Sensor Circuit - Circuit module measured a diagnostic system, check datalogger
voltage below threshold voltage below a signals, Ambient Air Temperature
specified range but not Sensor Voltage (0x03BA), Ambient Air
necessarily a short Temperature (0xF466). This DTC is set
circuit to ground when the ambient air temperature sensor
Harness failure - signal line voltage at the engine control
Ambient air module is less than the threshold value.
temperature sensor Refer to the electrical circuit diagrams
circuit and check both sides of the circuit for
Ambient air high resistance or short circuits. Repair
temperature sensor harness as required. Using the Jaguar
failure Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new ambient air
temperature sensor as required

P0070- Ambient Air Temperature The engine control Using the Jaguar Land Rover approved
17 Sensor Circuit - Circuit module measured a diagnostic system, check datalogger
voltage above threshold voltage above a signals, Ambient Air Temperature
specified range but not Sensor Voltage (0x03BA), Ambient Air
necessarily a short Temperature (0xF466). This DTC is set
circuit to power when the ambient air temperature sensor
Harness failure - signal line voltage at the engine control
Ambient air module is greater than the threshold
temperature sensor value. Refer to the electrical circuit
circuit diagrams and check both sides of the
Ambient air circuit for high resistance or short
temperature sensor circuits. Repair harness as required.
failure Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new ambient air
temperature sensor as required

P007A- Charge Air Cooler The engine control Using the Jaguar Land Rover approved
16 Temperature Sensor module measured a diagnostic system, check datalogger
Circuit (Bank 1) - Circuit voltage below a signals, Charge Air Temperature
voltage below threshold specified range but not Voltage (0x03EE). This DTC is set
necessarily a short when the air charge temperature sensor
circuit to ground signal line voltage at the engine control
Harness failure - Air module is less than the threshold value.
charge temperature Refer to the electrical circuit diagrams
sensor circuit and check both sides of the circuit for
Air charge high resistance or short circuits. Repair
temperature sensor harness as required. Using the Jaguar
failure Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new charge air
temperature sensor as required

P007A- Charge Air Cooler The engine control Using the Jaguar Land Rover approved
17 Temperature Sensor module measured a diagnostic system, check datalogger
Circuit (Bank 1) - Circuit voltage above a signals, Air Charge Temperature
voltage above threshold specified range but not (0x051C). This DTC is set when the air
necessarily a short charge temperature sensor signal line
circuit to power voltage at the engine control module is
Harness failure - Air greater than the threshold value. Refer
charge temperature to the electrical circuit diagrams and
sensor circuit check both sides of the circuit for high
Air charge resistance or short circuits. Repair
temperature sensor harness as required. Using the Jaguar
failure Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new charge air
temperature sensor as required

P007A- Charge Air Cooler Harness failure - Air Using the Jaguar Land Rover approved
62 Temperature Sensor charge temperature diagnostic system, check datalogger
Circuit (Bank 1) - Signal sensor circuit short signals, Charge Air Temperature
compare failure circuit to ground, short Voltage (0x03EE). Refer to the
circuit to power, high electrical circuit diagrams and check air
resistance, open circuit charge temperature sensor circuit for
Air charge short circuit to ground, short circuit to
temperature sensor power, high resistance, open circuit.
failure Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new charge air
temperature sensor as required

P0087- Fuel Rail/System Pressure Low level fuel Check the fuel volume available in the
00 - Too Low - No sub type condition fuel tank is sufficient, add fuel as
information Blocked fuel filter required. Using the Jaguar Land Rover
Fuel gauge sender unit approved diagnostic system, clear all
sticking stored DTCs using the ‘Diagnosis
Fuel lines restricted Menu’ tab and retest
Fuel lines leaking Using the Jaguar Land Rover approved
Fuel pump failure diagnostic equipment, measure the fuel
Fuel rail pressure pressure drop across the fuel filter (2
sensor signal circuit measurement points)
short circuit to ground, Measure point 1 (Input side of the
short circuit to power, fuel filter) Install 0 -14 Bar
open circuit, high pressure gauge between Fuel
resistance Supply to Fuel Filter Pipe and
Fuel rail pressure Fuel filter
sensor failure Engine at idle expected fuel
pressure 7 psi (0.5 bar)
Engine at 3000 RPM expected
fuel pressure 7 psi (0.5 bar)
Measure point 2 (Output side of
the fuel filter) Install 0 -14 Bar
pressure gauge between Fuel filter
and Fuel Filter to High Pressure
Diesel Injector Pump Pipe
Engine at idle expected fuel
pressure 7 psi (0.5 bar)
Engine at 3000 RPM expected
fuel pressure 7 psi (0.5 bar)
Fuel filter is blocked or starting to
block if fuel pressure (output side
of the fuel filter) is lower than
fuel pressure (input side of the
fuel filter)
Install a new fuel filter, only when
diagnosed as blocked
Check the fuel gauge sender units for
correct operation
Check fuel lines for restriction
Check fuel lines for leakage
Check for fuel pump related DTCs and
refer to the relevant DTC index
Refer to the electrical circuit diagrams
and check fuel rail pressure sensor
circuit for short circuit to ground, short
circuit to power, open circuit, high
resistance. Repair harness as required
Check and install new fuel rail pressure
sensor as required

P0087- Fuel Rail/System Pressure The engine control Using the Jaguar Land Rover approved
16 - Too Low - Circuit module measured a diagnostic equipment, measure the fuel
voltage below threshold voltage below a pressure drop across the fuel filter (2
specified range but not measurement points)
necessarily a short Measure point 1 (Input side of the
circuit to ground fuel filter) Install 0 -14 Bar
Blocked fuel filter pressure gauge between Fuel
Fuel rail pressure Supply to Fuel Filter Pipe and
sensor circuit, short Fuel filter
circuit to ground, open Engine at idle expected fuel
circuit, high resistance pressure 7 psi (0.5 bar)
Fuel rail pressure Engine at 3000 RPM expected
sensor failure fuel pressure 7 psi (0.5 bar)
Measure point 2 (Output side of
the fuel filter) Install 0 -14 Bar
pressure gauge between Fuel filter
and Fuel Filter to High Pressure
Diesel Injector Pump Pipe
Engine at idle expected fuel
pressure 7 psi (0.5 bar)
Engine at 3000 RPM expected
fuel pressure 7 psi (0.5 bar)
Fuel filter is blocked or starting to
block if fuel pressure (output side
of the fuel filter) is lower than
fuel pressure (input side of the
fuel filter)
Install a new fuel filter, only when
diagnosed as blocked
Refer to the electrical circuit diagrams
and check fuel rail pressure sensor
circuit for short circuit to ground, open
circuit, high resistance. Repair harness
as required. Using the Jaguar Land
Rover approved diagnostic system, clear
all stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Check and install new fuel rail pressure
sensor as required
P0087- Fuel Rail/System Pressure The engine control Using the Jaguar Land Rover approved
21 - Too Low - Signal module measured a diagnostic equipment, measure the fuel
amplitude < minimum signal voltage below a pressure drop across the fuel filter (2
specified range but not measurement points)
necessarily a short Measure point 1 (Input side of the
circuit to ground, gain fuel filter) Install 0 -14 Bar
low pressure gauge between Fuel
Blocked fuel filter Supply to Fuel Filter Pipe and
Fuel lines restricted Fuel filter
Fuel lines leaking Engine at idle expected fuel
Fuel injector's stuck pressure 7 psi (0.5 bar)
open, leaking Engine at 3000 RPM expected
Fuel pump failure fuel pressure 7 psi (0.5 bar)
Fuel rail pressure Measure point 2 (Output side of
sensor circuit short the fuel filter) Install 0 -14 Bar
circuit to ground, open pressure gauge between Fuel filter
circuit, high resistance and Fuel Filter to High Pressure
Fuel pressure control Diesel Injector Pump Pipe
valve circuit short Engine at idle expected fuel
circuit to ground, open pressure 7 psi (0.5 bar)
circuit, high resistance Engine at 3000 RPM expected
Fuel volume control fuel pressure 7 psi (0.5 bar)
valve circuit short Fuel filter is blocked or starting to
circuit to ground, open block if fuel pressure (output side
circuit, high resistance of the fuel filter) is lower than
Fuel rail pressure fuel pressure (input side of the
sensor failure fuel filter)
Fuel pressure control Install a new fuel filter, only when
valve failure diagnosed as blocked
Fuel volume control Check fuel lines for restriction
valve failure Check fuel lines for leakage
Check fuel injector's for stuck open,
leakage
Check for fuel pump related DTCs and
refer to the relevant DTC index
Refer to the electrical circuit diagrams
and check fuel rail pressure sensor
circuit for short circuit to ground, open
circuit, high resistance. Repair harness
as required
Refer to the electrical circuit diagrams
and check fuel pressure control valve
circuit for short circuit to ground, open
circuit, high resistance. Repair harness
as required
Refer to the electrical circuit diagrams
and check fuel volume control valve
circuit for short circuit to ground, open
circuit, high resistance. Repair harness
as required
Check and install new fuel rail pressure
sensor as required
Check and install new fuel pressure
control valve as required
Check and install new fuel volume
control valve as required
P0088- Fuel Rail/System Pressure Blocked fuel filter Using the Jaguar Land Rover approved
00 - Too High - No sub type Fuel gauge sender unit diagnostic equipment, measure the fuel
information sticking pressure drop across the fuel filter (2
Fuel rail pressure measurement points)
sensor signal circuit Measure point 1 (Input side of the
short circuit to power fuel filter) Install 0 -14 Bar
Fuel rail pressure pressure gauge between Fuel
sensor ground circuit Supply to Fuel Filter Pipe and
open circuit, high Fuel filter
resistance Engine at idle expected fuel
Fuel pressure control pressure 7 psi (0.5 bar)
valve circuit short Engine at 3000 RPM expected
circuit to power, fuel pressure 7 psi (0.5 bar)
ground, open circuit, Measure point 2 (Output side of
high resistance the fuel filter) Install 0 -14 Bar
Fuel volume control pressure gauge between Fuel filter
valve circuit short and Fuel Filter to High Pressure
circuit to power, Diesel Injector Pump Pipe
ground, open circuit, Engine at idle expected fuel
high resistance pressure 7 psi (0.5 bar)
Fuel rail pressure Engine at 3000 RPM expected
sensor failure fuel pressure 7 psi (0.5 bar)
Fuel pressure control Fuel filter is blocked or starting to
valve failure block if fuel pressure (output side
Fuel volume control of the fuel filter) is lower than
valve failure fuel pressure (input side of the
fuel filter)
Install a new fuel filter, only when
diagnosed as blocked
Check the fuel gauge sender units for
correct operation
Refer to the electrical circuit diagrams
and check fuel rail pressure sensor
circuit for short circuit to power. Repair
harness as required
Refer to the electrical circuit diagrams
and check fuel rail pressure sensor
ground circuit for open circuit, high
resistance. Repair harness as required
Refer to the electrical circuit diagrams
and check fuel pressure control valve
circuit for short circuit to power,
ground, open circuit, high resistance.
Repair harness as required
Refer to the electrical circuit diagrams
and check fuel volume control valve
circuit for short circuit to power,
ground, open circuit, high resistance.
Repair harness as required
Check and install new fuel rail pressure
sensor as required
Check and install new fuel pressure
control valve as required
Check and install new fuel volume
control valve as required

P0088- Fuel Rail/System Pressure The engine control Using the Jaguar Land Rover approved
17 - Too High - Circuit module measured a diagnostic equipment, measure the fuel
voltage above threshold voltage above a pressure drop across the fuel filter (2
specified range but not measurement points)
necessarily a short Measure point 1 (Input side of the
circuit to power fuel filter) Install 0 -14 Bar
Blocked fuel filter pressure gauge between Fuel
Fuel rail pressure Supply to Fuel Filter Pipe and
sensor signal circuit Fuel filter
short circuit to power Engine at idle expected fuel
pressure 7 psi (0.5 bar)
Engine at 3000 RPM expected
fuel pressure 7 psi (0.5 bar)
Measure point 2 (Output side of
the fuel filter) Install 0 -14 Bar
pressure gauge between Fuel filter
and Fuel Filter to High Pressure
Diesel Injector Pump Pipe
Engine at idle expected fuel
pressure 7 psi (0.5 bar)
Engine at 3000 RPM expected
fuel pressure 7 psi (0.5 bar)
Fuel filter is blocked or starting to
block if fuel pressure (output side
of the fuel filter) is lower than
fuel pressure (input side of the
fuel filter)
Install a new fuel filter, only when
diagnosed as blocked
Refer to the electrical circuit diagrams
and check fuel rail pressure sensor
circuit for short circuit to power

P0088- Fuel Rail/System Pressure The engine control Using the Jaguar Land Rover approved
22 - Too High - Signal module measured a diagnostic equipment, measure the fuel
amplitude > maximum signal voltage above a pressure drop across the fuel filter (2
specified range but not measurement points)
necessarily a short Measure point 1 (Input side of the
circuit to power, gain fuel filter) Install 0 -14 Bar
too high pressure gauge between Fuel
Blocked fuel filter Supply to Fuel Filter Pipe and
Fuel gauge sender unit Fuel filter
sticking Engine at idle expected fuel
Fuel lines restricted pressure 7 psi (0.5 bar)
Fuel rail pressure Engine at 3000 RPM expected
sensor circuit short fuel pressure 7 psi (0.5 bar)
circuit to power, Measure point 2 (Output side of
ground, open circuit, the fuel filter) Install 0 -14 Bar
high resistance pressure gauge between Fuel filter
Fuel pressure control and Fuel Filter to High Pressure
valve circuit short Diesel Injector Pump Pipe
circuit to power, Engine at idle expected fuel
ground, open circuit, pressure 7 psi (0.5 bar)
high resistance Engine at 3000 RPM expected
Fuel volume control fuel pressure 7 psi (0.5 bar)
valve circuit short Fuel filter is blocked or starting to
circuit to power, block if fuel pressure (output side
ground, open circuit, of the fuel filter) is lower than
high resistance fuel pressure (input side of the
Fuel rail pressure fuel filter)
sensor failure Install a new fuel filter, only when
Fuel pressure control diagnosed as blocked
valve failure Check the fuel gauge sender units for
Fuel volume control correct operation
valve failure Check fuel lines for restriction
Fuel pump failure Refer to the electrical circuit diagrams
and check fuel rail pressure sensor
circuit for short circuit to power,
ground, open circuit, high resistance.
Repair harness as required
Refer to the electrical circuit diagrams
and check fuel pressure control valve
circuit for short circuit to power,
ground, open circuit, high resistance.
Repair harness as required
Refer to the electrical circuit diagrams
and check fuel volume control valve
circuit for short circuit to power,
ground, open circuit, high resistance.
Repair harness as required
Check and install new fuel rail pressure
sensor as required
Check and install new fuel pressure
control valve as required
Check and install new fuel volume
control valve as required
Check for fuel pump related DTCs and
refer to the relevant DTC index

P0089- Fuel Pressure Regulator The engine control Refer to the electrical circuit diagrams
21 Performance - Signal module measured a and check fuel pressure regulator circuit
amplitude < minimum signal voltage below a for short circuit to ground, open circuit.
specified range but not Repair harness as required
necessarily a short Refer to the electrical circuit diagrams
circuit to ground, gain and check fuel pressure regulator
low reference voltage circuit for high
Fuel pressure regulator resistance. Repair harness as required
signal circuit short Check and install new fuel pressure
circuit to ground, open regulator as required
circuit
Fuel pressure regulator
reference voltage
circuit high resistance
Fuel pressure regulator
failure

P0089- Fuel Pressure Regulator The engine control Refer to the electrical circuit diagrams
22 Performance - Signal module measured a and check fuel pressure regulator circuit
amplitude > maximum signal voltage above a for short circuit to power. Repair
specified range but not harness as required
necessarily a short Check and install new fuel pressure
circuit to power, gain regulator as required
too high
Fuel pressure regulator
signal circuit short
circuit to power
Fuel pressure regulator
failure

P0090- Fuel Pressure Regulator 1 The engine control Using the Jaguar Land Rover approved
13 Control Circuit/Open - module has diagnostic system, check datalogger
Circuit open determined an open signals, Fuel Pressure Relief Control
circuit via lack of bias Valve Duty Cycle (0x03C3). Refer to
voltage, low current the electrical circuit diagrams and check
flow, no change in the the fuel pressure control valve control
state of an input in circuit for open circuit. Repair harness
response to an output as required. Using the Jaguar Land
Harness failure - Fuel Rover approved diagnostic system, clear
pressure control valve all stored DTCs using the ‘Diagnosis
control circuit open Menu’ tab and retest
circuit

P0090- Fuel Pressure Regulator 1 Fuel pressure control Using the Jaguar Land Rover approved
4B Control Circuit/Open - valve signal circuit diagnostic system, check datalogger
Over temperature short circuit to power, signals, Fuel Pressure Relief Control
open circuit Valve Duty Cycle (0x03C3). Refer to
Fuel pressure regulator the electrical circuit diagrams and check
failure fuel pressure control valve circuit for
short circuit to power, open circuit.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new fuel pressure
regulator as required

P0091- Fuel Pressure Regulator 1 The engine control Using the Jaguar Land Rover approved
11 Control Circuit Low - module has detected a diagnostic system, check datalogger
Circuit short to ground ground measurement signals, Fuel Pressure Relief Control
for a period longer Valve Duty Cycle (0x03C3). Refer to
than expected or has the electrical circuit diagrams and check
detected a ground the fuel pressure control valve circuit
measurement when for short circuit to ground. Check power
another value was supply circuit to control valve. Repair
expected harness as required. Using the Jaguar
Harness failure - Fuel Land Rover approved diagnostic
pressure control valve system, clear all stored DTCs using the
circuit short circuit to ‘Diagnosis Menu’ tab and retest
ground Check and install new fuel pressure
Fuel pressure control control valve as required
valve failure

P0091- Fuel Pressure Regulator 1 The engine control Using the Jaguar Land Rover approved
16 Control Circuit Low - module measured a diagnostic system, check datalogger
Circuit voltage below voltage below a signals, Fuel Pressure Relief Control
threshold specified range but not Valve Duty Cycle (0x03C3). This DTC
necessarily a short is set when the voltage on the fuel
circuit to ground pressure control valve circuit is less than
Harness failure - Fuel the threshold expected by the engine
pressure control valve control module. Refer to the electrical
circuit circuit diagrams and check the fuel
Fuel pressure control pressure control valve circuit for high
valve failure resistance, short circuit to ground.
Check power supply circuit to the fuel
pressure control valve. Repair harness
as required. Using the Jaguar Land
Rover approved diagnostic system, clear
all stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Check and install new fuel pressure
control valve as required

P0092- Fuel Pressure Regulator 1 The engine control Using the Jaguar Land Rover approved
12 Control Circuit High - module has detected a diagnostic system, check datalogger
Circuit short to battery vehicle power signals, Fuel Pressure Relief Control
measurement for a Valve Duty Cycle (0x03C3). Refer to
period longer than the electrical circuit diagrams and check
expected or has the fuel pressure control valve circuit
detected a vehicle for short circuit to power. Check power
power measurement supply circuit to control valve. Repair
when another value harness as required. Using the Jaguar
was expected Land Rover approved diagnostic
Harness failure - Fuel system, clear all stored DTCs using the
pressure control valve ‘Diagnosis Menu’ tab and retest
circuit short circuit to
power

P0092- Fuel Pressure Regulator 1 The engine control Using the Jaguar Land Rover approved
17 Control Circuit High - module measured a diagnostic system, check datalogger
Circuit voltage above voltage above a signals, Fuel Pressure Relief Control
threshold specified range but not Valve Duty Cycle (0x03C3). This DTC
necessarily a short is set when the voltage on the fuel
circuit to power pressure control valve circuit is more
Harness failure - Fuel than the threshold expected by the
pressure control valve engine control module. Refer to the
circuit electrical circuit diagrams and check the
Fuel pressure control fuel pressure control valve circuit for
valve failure high resistance, short circuit to power.
Check power supply circuit to the fuel
pressure control valve. Repair harness
as required. Using the Jaguar Land
Rover approved diagnostic system, clear
all stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Check and install new fuel pressure
control valve as required

P00AA- Intake Air Temperature The engine control Using the Jaguar Land Rover approved
16 Sensor 1 Circuit (Bank 2) - module measured a diagnostic system, check datalogger
Circuit voltage below voltage below a signals, Intake Air Temperature Sensor
threshold specified range but not (0x1279), Intake Air Temperature
necessarily a short (0xF40F). This DTC is set when the
circuit to ground voltage on the intake air temperature
Harness failure - sensor circuit is less than the threshold
Intake air temperature expected by the engine control module.
sensor circuit The intake air temperature sensor is
Intake air temperature integrated into the electronics package
sensor failure (part of of the mass air flow sensor and shares
mass air flow sensor) the same ground circuit as the mass air
flow element of the sensor. Refer to the
electrical circuit diagrams and check all
the circuits connected to the mass air
flow sensor for short circuit to ground,
short circuit to power, open circuit, high
resistance. Check mass air flow sensor 2
circuits as both sensors share the ground
connection. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new intake air
temperature sensor as required

P00AA- Intake Air Temperature The engine control Using the Jaguar Land Rover approved
17 Sensor 1 Circuit (Bank 2) - module measured a diagnostic system, check datalogger
Circuit voltage above voltage above a signals, Intake Air Temperature Sensor
threshold specified range but not (0x1279), Intake Air Temperature
necessarily a short (0xF40F). This DTC is set when the
circuit to power voltage on the intake air temperature
Harness failure - sensor circuit is more than the threshold
Intake air temperature expected by the engine control module.
sensor circuit The intake air temperature sensor is
Intake air temperature integrated into the electronics package
sensor failure (part of of the mass air flow sensor and shares
mass air flow sensor) the same ground circuit as the mass air
flow element of the sensor. Refer to the
electrical circuit diagrams and check all
the circuits connected to the mass air
flow sensor for short circuit to ground,
short circuit to power, open circuit, high
resistance. Check mass air flow sensor 2
circuits as both sensors share the ground
connection. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new intake air
temperature sensor as required

P00AA- Intake Air Temperature Harness failure - Refer to the electrical circuit diagrams
62 Sensor 1 Circuit (Bank 2) - Intake air temperature and check all the circuits connected to
Signal compare failure sensor circuit the mass air flow sensor for short circuit
Intake air temperature to ground, short circuit to power, open
sensor failure (part of circuit, high resistance. Check mass air
mass air flow sensor) flow sensor 2 circuits as both sensors
share the ground connection. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new intake air
temperature sensor as required
P00BC- Mass or Volume Air Flow Boost air solenoid If this DTC is logged with P1247-00,
00 A Circuit stuck shut bi-turbo suspect boost air solenoid stuck shut bi-
Range/Performance - Air mode turbo mode
Flow Too Low - No sub Turbine intake If this DTC is logged with P22D3-77 &
type information solenoid stuck shut P22CF-71, suspect turbine intake
Intake system low solenoid stuck shut
pressure boost leak Check the vacuum system, Charge air
bank 2 shut-off valve and Turbine intake shut-
off valve operation. Refer to section
303-04B or 303-04D and perform
pinpoint test A Vacuum Control System
Tests
If this DTC is logged with P006A-00,
suspect intake system low pressure
boost leak bank 2

P00BC- Mass or Volume Air Flow Air flow disruption at This DTC is set if the mass air flow
07 A Circuit sensing element of signal from sensor 1 is less than the
Range/Performance - Air mass air flow sensor value expected by the engine control
Flow Too Low - Mass air flow sensor module. Refer to the relevant sections of
Mechanical failures failure the workshop manual and check the
induction system for air leaks and
obstructions to flow. Check the
condition of the air filter and examine
the induction pipes for debris which
could disrupt air flow at the sensing
element. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Check and install new mass air flow
sensor as required

P00BC- Mass or Volume Air Flow Boost air solenoid If this DTC is logged with P1247-00,
64 A Circuit stuck shut bi-turbo suspect boost air solenoid stuck shut bi-
Range/Performance - Air mode turbo mode
Flow Too Low - Signal Turbine intake If this DTC is logged with P22D3-77 &
plausibility failure solenoid stuck shut P22CF-71, suspect turbine intake
Intake system low solenoid stuck shut
pressure boost leak If this DTC is logged with P006A-00,
bank 2 suspect intake system low pressure
boost leak bank 2
Refer to the relevant sections of the
workshop manual and check the
induction system for air leaks and
obstructions to flow. Check the
condition of the air filter and examine
the induction pipes for debris which
could disrupt air flow at the sensing
element. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest

P00BD- Mass or Volume Air Flow Air leak at air intake Refer to the relevant sections of the
00 A Circuit system A workshop manual and check the
Range/Performance - Air Harness failure - Mass induction system for air leaks
Flow Too High - No sub air flow sensor circuit Refer to the electrical circuit diagrams
type information short circuit to power and check mass air flow sensor for short
Mass air flow sensor circuit to power. Repair harness as
failure required. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Check and install new mass air flow
sensor as required

P00BD- Mass or Volume Air Flow Boost air solenoid If this DTC is logged with P0235-94
07 A Circuit stuck open mono turbo suspect, boost air solenoid stuck open
Range/Performance - Air mode mono turbo mode
Flow Too High - Turbine intake If this DTC is logged with P0235-94
Mechanical failures solenoid leakage when suspect, turbine intake solenoid leakage
closed when closed
Turbine intake If this DTC is logged with P0235-94,
solenoid stuck open P22D2-77, P1247-00 & P22CF-71
Intake air system, suspect, turbine intake solenoid stuck
blocked low pressure open
air intake. This failure Check the vacuum system, Charge air
mode can be caused shut-off valve and Turbine intake shut-
by snow packing in off valve operation. Refer to section
the intake system. 303-04B or 303-04D and perform
Symptoms often pinpoint test A Vacuum Control System
disappear after the Tests
vehicle has been If this DTC is logged with P0235-94,
warmed and heat P22D2-77, P1247-00 & P22CF-71
soaked. Similar suspect, intake air system, blocked low
symptoms to seized pressure air intake
primary turbo If this DTC is logged with P00BE-07 &
Primary turbo charger P1247-00 suspect, primary turbocharger
seized seized
Using the Jaguar Land Rover Approved
Diagnostic Equipment, perform the
(Turbo, EGR and air path dynamic test)
routine

P00BD- Mass or Volume Air Flow Boost air solenoid If this DTC is logged with P0235-94
64 A Circuit stuck open mono turbo suspect, boost air solenoid stuck open
Range/Performance - Air mode mono turbo mode
Flow Too High - Signal Turbine intake If this DTC is logged with P0235-94
plausibility failure solenoid leakage when suspect, turbine intake solenoid leakage
closed when closed
Turbine intake If this DTC is logged with P0235-94,
solenoid stuck open P22D2-77, P1247-00 & P22CF-71
mono turbo mode suspect, turbine intake solenoid stuck
Intake system high open
pressure bank 2 in Using the Jaguar Land Rover approved
mono turbo mode diagnostic system, perform the (Turbo,
EGR and air path dynamic test) routine

P00BE- Mass or Volume Air Flow Intake air system, high Check and correct intake air system,
00 B Circuit pressure boost leak high pressure boost leak
Range/Performance - Air Air leak at air intake Check and correct air leak at air intake
Flow Too Low - No sub system system
type information Charge air shut-off Check the vacuum system, Charge air
valve failure shut-off valve and Turbine intake shut-
Turbine intake shut- off valve operation. Refer to section
off valve failure 303-04B or 303-04D and perform
pinpoint test A Vacuum Control System
Tests
Using the Jaguar Land Rover Approved
Diagnostic Equipment, clear all stored
DTCs and retest

P00BE- Mass or Volume Air Flow Boost air recirculation If this DTC is logged with P1247-00,
07 B Circuit solenoid stuck open suspect boost air recirculation solenoid
Range/Performance - Air bi-turbo mode stuck open
Flow Too Low - Airflow disruption at Check the vacuum system, Charge air
Mechanical failures sensing element of shut-off valve and Turbine intake shut-
mass air flow sensor 2 off valve operation. Refer to section
Mass air flow sensor 2 303-04B or 303-04D and perform
circuit short circuit to pinpoint test A Vacuum Control System
ground, open circuit, Tests
high resistance Check the condition of the air filter and
Mass air flow sensor 2 examine the induction pipes for debris
failure which could disrupt air flow at the
sensing element
Refer to the electrical circuit diagrams
and check the mass air flow sensor 2 for
short circuit to ground, open circuit,
high resistance. Repair wiring as
required, Using the Jaguar Land Rover
Approved Diagnostic Equipment, clear
all stored DTCs and retest
If the DTC resets suspect the mass air
flow sensor. Check and install a new
mass air flow sensor 2 as required

P00BF- Mass or Volume Air Flow Charge air shut-off Check the vacuum system, Charge air
00 B Circuit valve failure shut-off valve and Turbine intake shut-
Range/Performance - Air Turbine intake shut- off valve operation. Refer to section
Flow Too High - No sub off valve failure 303-04B or 303-04D and perform
type information Intake air system, high pinpoint test A Vacuum Control System
pressure boost leak Tests
Check and correct intake air system,
high pressure boost leak
Using the Jaguar Land Rover Approved
Diagnostic Equipment, clear all stored
DTCs and retest

P00BF- Mass or Volume Air Flow Intake air system, high If this DTC is logged with P1247-00,
07 B Circuit pressure boost leak P006A-00 & P00BF-07, suspect intake
Range/Performance - Air air system, high pressure boost leak
Flow Too High -
Mechanical failures
P00CF- Secondary Compressor Boost air circuit leak This DTC is set when the engine control
62 Outlet Pressure Sensor - or blockage module detects a signal compare failure
Signal compare failure Boost air recirculation on the boost air pressure sensor signal.
solenoid failure Check the sensor hose for blockages or
Boost air solenoid leaks. Check the sensor and harness for
failure mechanical damage caused by heat or
Mechanical failure - chaffing
Sensor hose blocked Refer to the electrical circuit diagrams
or leaking and check the secondary compressor
Harness failure - Boost outlet pressure sensor power and ground
air pressure sensor supplies for short circuit to ground, open
circuit circuit. Check the signal line for short
Boost air pressure circuit to ground, short circuit to power,
sensor failure open circuit. Repair harness as required
Check and install new secondary
compressor outlet pressure sensor as
required

P0101- Mass or Volume Air Flow The engine control This DTC is set if the mass air flow
21 A Circuit module measured a signal from sensor 1 is less than the
Range/Performance - signal voltage below a value expected by the engine control
Signal amplitude < specified range but not module. Refer to the relevant sections of
minimum necessarily a short the workshop manual and check the
circuit to ground, gain induction system for air leaks and
low obstructions to flow. Check the
Air flow disruption at condition of the air filter and examine
sensing element of the induction pipes for debris which
mass air flow sensor could disrupt air flow at the sensing
Harness failure - Mass element
air flow sensor circuit Refer to the electrical circuit diagrams
short circuit to ground, and check mass air flow sensor circuit
high resistance, open for short circuit to ground, high
circuit resistance, open circuit. Repair harness
Mass air flow sensor as required. Using the Jaguar Land
failure Rover approved diagnostic system, clear
all stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Check and install new mass air flow
sensor as required

P0101- Mass or Volume Air Flow The engine control This DTC is set if the mass air flow
22 A Circuit module measured a signal from sensor 1 is more than the
Range/Performance - signal voltage above a value expected by the engine control
Signal amplitude > specified range but not module. Refer to the relevant sections of
maximum necessarily a short the workshop manual and check the
circuit to power, gain induction system for air leaks and
too high obstructions to flow. Check the
Air flow disruption at condition of the air filter and examine
sensing element of the induction pipes for debris which
mass air flow sensor could disrupt air flow at the sensing
Harness failure - Mass element
air flow sensor circuit Refer to the electrical circuit diagrams
short circuit to power and check mass air flow sensor circuit
Mass air flow sensor for short circuit to power. Repair
failure harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new mass air flow
sensor as required

P0101- Mass or Volume Air Flow Air flow disruption at This DTC is set if the mass air flow
92 Sensor "A" Circuit sensing element of signal from sensor 1 is less than the
Range/Performance - mass air flow sensor value expected by the engine control
Performance or incorrect Harness failure - Mass module. Refer to the relevant sections of
operation air flow sensor circuit the workshop manual and check the
short circuit to ground, induction system for air leaks and
short circuit to power, obstructions to flow. Check the
open circuit, high condition of the air filter and examine
resistance the induction pipes for debris which
Mass air flow sensor could disrupt air flow at the sensing
failure element
Refer to the electrical circuit diagrams
and check mass air flow sensor circuit
for short circuit to ground, short circuit
to power, open circuit, high resistance.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new mass air flow
sensor as required

P0102- Mass or Volume Air Flow Air flow disruption at Using the Jaguar Land Rover approved
00 A Circuit Low - No sub sensing element of diagnostic system, check datalogger
type information mass air flow sensor signals, Air Flow Rate From mass air
Harness failure - Mass flow Sensor Bank 1 (0x0504). This
air flow sensor circuits DTC is set if the mass air flow signal
Mass air flow sensor from sensor 1 is less than the value
failure expected by the engine control module.
Refer to the relevant sections of the
workshop manual and check the
induction system for air leaks and
obstructions to flow. Check the
condition of the air filter and examine
the induction pipes for debris which
could disrupt air flow at the sensing
element
Refer to the electrical circuit diagrams
and check the mass air flow sensor
power and ground circuits for high
resistance, short circuit to power, short
circuit to ground. Check the mass air
flow signal line for high resistance.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new mass air flow
sensor as required

P0103- Mass or Volume Air Flow Air flow disruption at Using the Jaguar Land Rover approved
00 A Circuit High - No sub sensing element of diagnostic system, check datalogger
type information mass air flow sensor signals, Air Flow Rate From Mass Air
Harness failure - Mass Flow Sensor Bank 1 (0x0504). This
air flow sensor circuits DTC is set if the mass air flow signal
Mass air flow sensor from sensor 1 is greater than the value
failure expected by the engine control module.
Refer to the relevant sections of the
workshop manual and check the
induction system for air leaks and
obstructions to flow. Check the
condition of the air filter and examine
the induction pipes for debris which
could disrupt air flow at the sensing
element.
Refer to the electrical circuit diagrams
and check the mass air flow sensor
power and ground circuits for high
resistance, short circuit to power, short
circuit to ground. Check the mass air
flow signal line for high resistance.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new mass air flow
sensor as required

P0105- Manifold Absolute The engine control Refer to the electrical circuit diagrams
16 Pressure/BARO circuit - module measured a and check the 5 volt supply circuit for
Circuit voltage below voltage below a open circuit, high resistance, short
threshold specified range but not circuit to ground. Check the sensor
necessarily a short ground for open circuit, short circuit to
circuit to ground power. Check the signal circuit for short
Harness failure - circuit to ground, high resistance. Repair
Manifold absolute harness as required. Using the Jaguar
pressure sensor Land Rover approved diagnostic
circuits system, clear all stored DTCs using the
Manifold absolute ‘Diagnosis Menu’ tab and retest
pressure sensor failure Check and install new manifold absolute
Blockage or leak pressure sensor as required
between the intake Using the Jaguar Land Rover approved
manifold and the diagnostic system, check datalogger
manifold absolute signals, Corrected Intake Manifold
pressure sensor Absolute Pressure (0x0322), Manifold
Absolute Pressure Sensor Voltage
(0x0301), Manifold Absolute Pressure
Bank 1 (0x052C). This DTC is set when
the voltage on the manifold absolute
pressure sensor signal circuit is less than
the threshold expected by the engine
control module. Refer to the workshop
manual and check the manifold absolute
pressure sensor is correctly connected to
the air intake manifold and there are no
blockages or air leaks preventing
communication of pressure changes
between the manifold and the sensor

P0105- Manifold Absolute The engine control Refer to the electrical circuit diagrams
17 Pressure/BARO circuit - module measured a and check the 5 volt supply circuit for
Circuit voltage above voltage above a short circuit to power. Check the sensor
threshold specified range but not ground for open circuit, short circuit to
necessarily a short power. Check the signal circuit for short
circuit to power circuit to power. Repair harness as
Harness failure - required. Using the Jaguar Land Rover
Manifold absolute approved diagnostic system, clear all
pressure sensor stored DTCs using the ‘Diagnosis
circuits Menu’ tab and retest
Manifold absolute Check and install new manifold absolute
pressure sensor failure pressure sensor as required
Blockage or leak Using the Jaguar Land Rover approved
between the intake diagnostic system, check datalogger
manifold and the signals, Corrected Intake Manifold
manifold pressure Absolute Pressure (0x0504), Manifold
sensor Absolute Pressure Sensor Voltage
(0x0301), Manifold Absolute Pressure
Bank 1 (0x052C). This DTC is set when
the voltage on the manifold absolute
pressure sensor signal circuit is greater
than the threshold expected by the
engine control module. Refer to the
workshop manual and check the
manifold absolute pressure sensor is
correctly connected to the air intake
manifold and there are no blockages or
air leaks preventing communication of
pressure changes between the manifold
and the sensor

P0105- Manifold Absolute Harness failure - Refer to the electrical circuit diagrams
65 Pressure/Barometric Manifold absolute and check the 5 volt supply circuit for
Pressure Sensor Circuit - pressure sensor short circuit to power. Check the sensor
Signal has too few circuits ground for open circuit, short circuit to
transitions/events Manifold absolute power. Check the signal circuit for short
pressure sensor failure circuit to power. Repair harness as
Blockage or leak required. Using the Jaguar Land Rover
between the intake approved diagnostic system, clear all
manifold and the stored DTCs using the ‘Diagnosis
manifold pressure Menu’ tab and retest
sensor Check and install new manifold absolute
pressure sensor as required
Using the Jaguar Land Rover approved
diagnostic system, check datalogger
signals, Corrected Intake Manifold
Absolute Pressure (0x0504), Manifold
Absolute Pressure Sensor Voltage
(0x0301), Manifold Absolute Pressure
Bank 1 (0x052C). Refer to the
workshop manual and check the
manifold absolute pressure sensor is
correctly connected to the air intake
manifold and there are no blockages or
air leaks preventing communication of
pressure changes between the manifold
and the sensor

P0107- Manifold Absolute Harness failure - Refer to the electrical circuit diagrams
00 Pressure/Barometric Manifold absolute and check the 5 volt supply circuit for
Pressure Sensor Circuit pressure sensor short circuit to power. Check the sensor
Low - No sub type circuits ground for open circuit, short circuit to
information Manifold absolute power. Check the signal circuit for short
pressure sensor failure circuit to power. Repair harness as
Blockage or leak required. Using the Jaguar Land Rover
between the intake approved diagnostic system, clear all
manifold and the stored DTCs using the ‘Diagnosis
manifold pressure Menu’ tab and retest
sensor Check and install new manifold absolute
pressure sensor as required
Using the Jaguar Land Rover approved
diagnostic system, check datalogger
signals, Corrected Intake Manifold
Absolute Pressure (0x0504), Manifold
Absolute Pressure Sensor Voltage
(0x0301), Manifold Absolute Pressure
Bank 1 (0x052C). Refer to the
workshop manual and check the
manifold absolute pressure sensor is
correctly connected to the air intake
manifold and there are no blockages or
air leaks preventing communication of
pressure changes between the manifold
and the sensor

P0107- Manifold Absolute The engine control Refer to the electrical circuit diagrams
16 Pressure/Barometric module measured a and check the 5 volt supply circuit for
Pressure Sensor Circuit voltage below a open circuit, short circuit to power,
Low - Circuit voltage specified range but not short circuit to ground. Check the sensor
below threshold necessarily a short ground for open circuit, short circuit to
circuit to ground power. Check the signal circuit for open
Harness failure - circuit, short circuit to power, short
Manifold absolute circuit to ground. Repair harness as
pressure sensor required. Using the Jaguar Land Rover
circuits approved diagnostic system, clear all
Manifold absolute stored DTCs using the ‘Diagnosis
pressure sensor failure Menu’ tab and retest
Blockage or leak Check and install new manifold absolute
between the intake pressure sensor as required
manifold and the Using the Jaguar Land Rover approved
manifold pressure diagnostic system, check datalogger
sensor signals, Corrected Intake Manifold
Absolute Pressure (0x0504), Manifold
Absolute Pressure Sensor Voltage
(0x0301), Manifold Absolute Pressure
Bank 1 (0x052C). This DTC is set when
the manifold absolute pressure sensor
signal voltage is lower than expected by
the engine control module. Refer to the
workshop manual and check the
manifold absolute pressure sensor is
correctly connected to the air intake
manifold and there are no blockages or
air leaks preventing communication of
pressure changes between the manifold
and the sensor

P0108- Manifold Absolute Harness failure - Refer to the electrical circuit diagrams
00 Pressure/Barometric Manifold absolute and check the 5 volt supply circuit for
Pressure Sensor Circuit pressure sensor open circuit, short circuit to power,
High - No sub type circuits short circuit to ground. Check the sensor
information Manifold absolute ground for open circuit, short circuit to
pressure sensor failure power. Check the signal circuit for open
Blockage or leak circuit, short circuit to power, short
between the intake circuit to ground. Repair harness as
manifold and the required. Using the Jaguar Land Rover
manifold pressure approved diagnostic system, clear all
sensor stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Check and install new manifold absolute
pressure sensor as required
Using the Jaguar Land Rover approved
diagnostic system, check datalogger
signals, Corrected Intake Manifold
Absolute Pressure (0x0504), Manifold
Absolute Pressure Sensor Voltage
(0x0301), Manifold Absolute Pressure
Bank 1 (0x052C). Refer to the
workshop manual and check the
manifold absolute pressure sensor is
correctly connected to the air intake
manifold and there are no blockages or
air leaks preventing communication of
pressure changes between the manifold
and the sensor

P0108- Manifold Absolute The engine control Refer to the electrical circuit diagrams
17 Pressure/Barometric module measured a and check the 5 volt supply circuit for
Pressure Sensor Circuit voltage above a open circuit, short circuit to power,
High - Circuit voltage specified range but not short circuit to ground. Check the sensor
above threshold necessarily a short ground for open circuit, short circuit to
circuit to power power. Check the signal circuit for open
Harness failure - circuit, short circuit to power, short
Manifold absolute circuit to ground. Repair harness as
pressure sensor required. Using the Jaguar Land Rover
circuits approved diagnostic system, clear all
Manifold absolute stored DTCs using the ‘Diagnosis
pressure sensor failure Menu’ tab and retest
Blockage or leak Check and install new manifold absolute
between the intake pressure sensor as required
manifold and the Using the Jaguar Land Rover approved
manifold pressure diagnostic system, check datalogger
sensor signals, Corrected Intake Manifold
Absolute Pressure (0x0504), Manifold
Absolute Pressure Sensor Voltage
(0x0301), Manifold Absolute Pressure
Bank 1 (0x052C). This DTC is set when
the manifold absolute pressure sensor
signal voltage is greater than expected
by the engine control module. Refer to
the workshop manual and check the
manifold absolute pressure sensor is
correctly connected to the air intake
manifold and there are no blockages or
air leaks preventing communication of
pressure changes between the manifold
and the sensor
P010A- Mass or Volume Air Flow Air flow disruption at This DTC is set if the mass air flow
92 Sensor "B" Circuit - sensing element of signal from sensor 2 is greater than the
Performance or incorrect mass air flow value expected by the engine control
operation Harness failure - Mass module. Refer to the relevant sections of
air flow sensor circuit the workshop manual and check the
short circuit to ground, induction system for air leaks and
short circuit to power, obstructions to flow. Check the
open circuit, high condition of the air filter and examine
resistance the induction pipes for debris which
Mass air flow failure could disrupt air flow at the sensing
element
Refer to the electrical circuit diagrams
and check mass air flow sensor 2 for
short circuit to ground, short circuit to
power, open circuit, high resistance.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new mass air flow
sensor 2 as required

P010B- Mass or Volume Air Flow The engine control This DTC is set if the mass air flow
21 B Circuit module measured a signal from sensor 2 is less than the
Range/Performance - signal voltage below a value expected by the engine control
Signal amplitude < specified range but not module. Refer to the relevant sections of
minimum necessarily a short the workshop manual and check the
circuit to ground, gain induction system for air leaks and
low obstructions to flow. Check the
Air flow disruption at condition of the air filter and examine
sensing element of the induction pipes for debris which
mass air flow could disrupt air flow at the sensing
Harness failure - Mass element
air flow sensor circuit Refer to the electrical circuit diagrams
short circuit to ground, and check mass air flow sensor 2 for
high resistance, open short circuit to ground, high resistance,
circuit open circuit. Repair harness as required.
Mass air flow failure Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new mass air flow
sensor 2 as required

P010B- Mass or Volume Air Flow The engine control This DTC is set if the mass air flow
22 B Circuit module measured a signal from sensor 2 is more than the
Range/Performance - signal voltage above a value expected by the engine control
Signal amplitude > specified range but not module. Refer to the relevant sections of
maximum necessarily a short the workshop manual and check the
circuit to power, gain induction system for air leaks and
too high obstructions to flow. Check the
Air flow disruption at condition of the air filter and examine
sensing element of the induction pipes for debris which
mass air flow sensor 2 could disrupt air flow at the sensing
Harness failure - Mass element
air flow sensor circuit Refer to the electrical circuit diagrams
short circuit to power and check mass air flow sensor 2 circuit
Mass air flow failure for short circuit to power. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new mass air flow
sensor 2 as required

P010C- Mass or Volume Air Flow Air flow disruption at Using the Jaguar Land Rover approved
00 B Circuit Low - No sub sensing element of diagnostic system, check datalogger
type information mass air flow signals, Air Flow Rate From Mass Air
Harness failure - Mass Flow Sensor Bank 2 (0x0505). This
air flow sensor circuits DTC is set if the mass air flow signal
Mass air flow failure from sensor 2 is less than the value
expected by the engine control module.
Refer to the relevant sections of the
workshop manual and check the
induction system for air leaks and
obstructions to flow. Check the
condition of the air filter and examine
the induction pipes for debris which
could disrupt air flow at the sensing
element
Refer to the electrical circuit diagrams
and check the power and ground circuits
for the mass air flow sensors for high
resistance, short circuit to power, short
circuit to ground. Check the mass air
flow signal line between the engine
control module and the mass air flow
sensor for high resistance. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new mass air flow
sensor as required

P010D- Mass or Volume Air Flow Air flow disruption at Using the Jaguar Land Rover approved
00 B Circuit High - No sub sensing element of diagnostic system, check datalogger
type information mass air flow signals, Air Flow Rate From Mass Air
Harness failure - Mass Flow Sensor Bank 2 (0x0505). This
air flow sensor circuits DTC is set if the mass air flow signal
Mass air flow failure from sensor 2 is greater than the value
expected by the engine control module.
Refer to the relevant sections of the
workshop manual and check the
induction system for air leaks and
obstructions to flow. Check the
condition of the air filter and examine
the induction pipes for debris which
could disrupt air flow at the sensing
element
Refer to the electrical circuit diagrams
and check the power and ground circuits
for the mass air flow sensors for high
resistance, short circuit to power, short
circuit to ground. Check the mass air
flow signal line between the engine
control module and the mass air flow
sensor for high resistance. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new mass air flow
sensor as required

P0116- Engine Coolant Engine coolant level Using the Jaguar Land Rover approved
00 Temperature Sensor 1 or flow failure diagnostic system, check datalogger
Circuit Range/Performance Harness failure - signals, Engine Coolant Temperature
- No sub type information Engine coolant Sensor (0x0357), Engine Coolant
temperature sensor Temperature (0xF405). This DTC is set
circuits if the engine coolant temperature value
Engine coolant fails plausibility checks by the engine
temperature sensor control module. Refer to the workshop
failure manual and check the engine cooling
system to ensure the coolant condition
and level is correct
Refer to the electrical circuit diagrams
and check the engine coolant
temperature sensor circuits for high
resistance, short circuit to other circuits.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new engine coolant
temperature sensor as required

P0116- Engine Coolant The engine control Using the Jaguar Land Rover approved
16 Temperature Sensor 1 module measured a diagnostic system, check datalogger
Circuit Range/Performance voltage below a signals, Engine Coolant Temperature
- Circuit voltage below specified range but not Sensor (0x0357), Engine Coolant
threshold necessarily a short Temperature (0xF405). This DTC is set
circuit to ground if the engine coolant temperature sensor
Engine coolant level signal voltage is less than the value
or flow failure expected by the engine control module.
Harness failure - Refer to the workshop manual and
Engine coolant check the engine cooling system to
temperature sensor ensure the coolant condition and level is
circuits correct
Engine coolant Refer to the electrical circuit diagrams
temperature sensor and check the engine coolant
failure temperature sensor circuits for high
resistance, short circuit to other circuits.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new engine coolant
temperature sensor as required

P0116- Engine Coolant The engine control Using the Jaguar Land Rover approved
17 Temperature Sensor 1 module measured a diagnostic system, check datalogger
Circuit Range/Performance voltage above a signals, Engine Coolant Temperature
- Circuit voltage above specified range but not Sensor (0x0357), Engine Coolant
threshold necessarily a short Temperature (0xF405). This DTC is set
circuit to power if the engine coolant temperature sensor
Engine coolant level signal voltage is greater than the value
or flow failure expected by the control module. Refer
Harness failure - to the workshop manual and check the
Engine coolant engine cooling system to ensure the
temperature sensor coolant condition and level is correct
circuits Refer to the electrical circuit diagrams
Engine coolant and check the engine coolant
temperature sensor temperature sensor circuits for high
failure resistance, short circuit to other circuits.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new engine coolant
temperature sensor as required

P0116- Engine Coolant The engine control Using the Jaguar Land Rover approved
21 Temperature Sensor 1 module measured a diagnostic system, check datalogger
Circuit Range/Performance signal voltage below a signals, Engine Coolant Temperature
- Signal amplitude < specified range but not Sensor (0x0357), Engine Coolant
minimum necessarily a short Temperature (0xF405). This DTC is set
circuit to ground, gain if the engine coolant temperature sensor
low signal amplitude is lower than the value
Engine coolant level expected by the control module. Refer
or flow failure to the workshop manual and check the
Harness failure - engine cooling system to ensure the
Engine coolant coolant condition and level is correct
temperature sensor Refer to the electrical circuit diagrams
circuit short circuit to and check the engine coolant
ground, high temperature sensor circuit for short
resistance, open circuit circuit to ground, high resistance, open
Engine coolant circuit. Repair harness as required.
temperature sensor Using the Jaguar Land Rover approved
failure diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new engine coolant
temperature sensor as required

P0116- Engine Coolant The engine control Using the Jaguar Land Rover approved
22 Temperature Sensor 1 module measured a diagnostic system, check datalogger
Circuit Range/Performance signal voltage above a signals, Engine Coolant Temperature
- Signal amplitude > specified range but not Sensor (0x0357), Engine Coolant
maximum necessarily a short Temperature (0xF405). This DTC is set
circuit to power, gain if the engine coolant temperature sensor
too high signal amplitude is greater than the
Engine coolant level value expected by the control module.
or flow failure Refer to the workshop manual and
Harness failure - check the engine cooling system to
Engine coolant ensure the coolant condition and level is
temperature sensor correct
circuit short circuit to Refer to the electrical circuit diagrams
power and check the engine coolant
Engine coolant temperature sensor circuit for short
temperature sensor circuit to power. Repair harness as
failure required. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Check and install new engine coolant
temperature sensor as required

P0130- O2 Sensor Circuit (Bank 1 Harness failure - Refer to the electrical circuit diagrams
00 Sensor 1) - No sub type Heated oxygen sensor and check the heated oxygen sensor
information circuit open circuit circuits for open circuit. Repair harness
Heated oxygen sensor as required. Using the Jaguar Land
component failure Rover approved diagnostic system, clear
all stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Check and install new heated oxygen
sensor as required

P0130- O2 Circuit (Bank 1, Sensor The engine control Refer to the electrical circuit diagrams
11 1) - Circuit short to ground module has detected a and check the heated oxygen sensor
ground measurement circuits for short circuit to ground.
for a period longer Repair harness as required. Using the
than expected or has Jaguar Land Rover approved diagnostic
detected a ground system, clear all stored DTCs using the
measurement when ‘Diagnosis Menu’ tab and retest
another value was Check and install new heated oxygen
expected sensor as required
Harness failure -
Heated oxygen sensor
circuit short circuit to
ground
Heated oxygen sensor
component failure

P0130- O2 Circuit (Bank 1, Sensor The engine control Refer to the electrical circuit diagrams
12 1) - Circuit short to battery module has detected a and check the heated oxygen sensor
vehicle power circuits for short circuit to power.
measurement for a Repair harness as required. Using the
period longer than Jaguar Land Rover approved diagnostic
expected or has system, clear all stored DTCs using the
detected a vehicle ‘Diagnosis Menu’ tab and retest
power measurement Check and install new heated oxygen
when another value sensor as required
was expected
Harness failure -
Heated oxygen sensor
circuit short circuit to
power
Heated oxygen sensor
component failure

P0130- O2 Circuit (Bank 1, Sensor The engine control Refer to the electrical circuit diagrams
13 1) - Circuit open module has and check the heated oxygen sensor
determined an open circuits for open circuit. Repair harness
circuit via lack of bias as required. Using the Jaguar Land
voltage, low current Rover approved diagnostic system, clear
flow, no change in the all stored DTCs using the ‘Diagnosis
state of an input in Menu’ tab and retest
response to an output Check and install new heated oxygen
Harness failure - sensor as required
Heated oxygen sensor
circuit open circuit
Heated oxygen sensor
component failure

P0130- O2 Circuit (Bank 1, Sensor Harness failure - This DTC is set when the heated oxygen
1A 1) - Circuit resistance Heated oxygen sensor sensor internal trim resistance value is
below threshold circuit failure less than that expected by the engine
Heated oxygen sensor control module. Refer to the electrical
component failure circuit diagrams and check the heated
oxygen sensor circuits for short circuits.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new heated oxygen
sensor as required

P0130- O2 Circuit (Bank 1, Sensor Harness failure - This DTC is set when the oxygen sensor
1B 1) - Circuit resistance Heated oxygen sensor internal trim resistance value is greater
above threshold circuit failure than that expected by the engine control
Heated oxygen sensor module. Refer to the electrical circuit
component failure diagrams and check the heated oxygen
sensor circuits for short circuits, open
circuits. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new heated oxygen
sensor as required

P0130- O2 Circuit (Bank 1, Sensor The signal transitions Check for and rectify any exhaust leak
26 1) - Signal rate of change more slowly than is between cylinder head and catalytic
below threshold reasonably allowed converter. Check heated oxygen sensor
Exhaust system leak is correctly installed in exhaust manifold
Fuel control system Check fuel control system for related
failure DTCs and refer to the relevant DTC
Heated oxygen sensor index
to engine control Refer to the electrical circuit diagrams
module circuit short and check heated oxygen sensor to
circuit to ground, short engine control module circuit for short
circuit to power, high circuit to ground, short circuit to power,
resistance high resistance, open circuit. Repair
Heated oxygen sensor harness as required. Using the Jaguar
failure Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new heated oxygen
sensor as required
P0133- O2 Circuit Slow Response Exhaust system leak Check for and rectify any exhaust leak
00 (Bank 1, Sensor 1) - No Fuel control system between cylinder head and catalytic
sub type information failure converter. Check heated oxygen sensor
Heated oxygen sensor is correctly installed in exhaust manifold
to engine control Check fuel control system for related
module wiring shield DTCs and refer to the relevant DTC
high resistance index
Heated oxygen sensor Refer to the electrical circuit diagrams
failure and check heated oxygen sensor to
engine control module wiring shield for
high resistance. Repair harness as
required. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Check and install new heated oxygen
sensor as required

P0135- O2 Sensor Heater Circuit Heated oxygen sensor Check fuel control system for related
16 (Bank 1 Sensor 1) - Circuit to engine control DTCs and refer to the relevant DTC
voltage below threshold module circuit short index
circuit to ground, open Refer to the electrical circuit diagrams
circuit and check heated oxygen sensor to
Heated oxygen sensor engine control module circuit for short
failure circuit to ground, open circuit
Check and install new heated oxygen
sensor as required

P0148- Fuel Delivery Error - No This DTC is set after Check high pressure fuel pump for
00 sub type information the engine control mechanical damage and excessive wear
module internal Using the Jaguar Land Rover approved
monitoring function diagnostic system, clear all stored DTCs
has evaluated high using the ‘Diagnosis Menu’ tab and
pressure fuel pump retest
fatigue and wear Check and install new high pressure fuel
against fuel rail pump as required
pressure

P0181- Fuel Temperature Sensor The engine control Using the Jaguar Land Rover approved
16 A Circuit module measured a diagnostic system, check datalogger
Range/Performance - voltage below a signals, Fuel Temperature "A"
Circuit voltage below specified range but not (0x0522), Fuel Rail Temperature Sensor
threshold necessarily a short Voltage (0x033F). This DTC is set
circuit to ground when the voltage on the fuel
Harness failure - Fuel temperature sensor circuit is less than
temperature sensor that expected by the engine control
circuit failure module. Refer to the electrical circuit
Sensor component diagrams and check the fuel temperature
failure sensor signal circuit for short circuit to
ground. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new fuel temperature
sensor as required
P0181- Fuel Temperature Sensor The engine control Using the Jaguar Land Rover approved
17 A Circuit module measured a diagnostic system, check datalogger
Range/Performance - voltage above a signals, Fuel Temperature "A"
Circuit voltage above specified range but not (0x0522), Fuel Rail Temperature Sensor
threshold necessarily a short Voltage (0x033F). This DTC is set
circuit to power when the voltage on the fuel
Harness failure - Fuel temperature sensor circuit is greater than
temperature sensor that expected by the engine control
circuit failure module. Refer to the electrical circuit
Sensor component diagrams and check the fuel temperature
failure sensor signal and ground circuits for
short circuit to power, open circuit or
high resistance. Repair harness as
required. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Check and install new fuel temperature
sensor as required

P0182- Fuel Temperature Sensor Harness failure - Fuel Using the Jaguar Land Rover approved
00 A Circuit Low - No sub temperature sensor diagnostic system, check datalogger
type information circuit failure signals, Fuel Temperature "A"
Sensor component (0x0522), Fuel Rail Temperature Sensor
failure Voltage (0x033F). This DTC is set
when the voltage on the fuel
temperature sensor circuit is less than
that expected by the engine control
module. Refer to the electrical circuit
diagrams and check the fuel temperature
sensor signal circuit for short circuit to
ground. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new fuel temperature
sensor as required

P0183- Fuel Temperature Sensor Harness failure - Fuel Using the Jaguar Land Rover approved
00 A Circuit High - No sub temperature sensor diagnostic system, check datalogger
type information circuit failure signals, Fuel Temperature "A"
Sensor component (0x0522), Fuel Rail Temperature Sensor
failure Voltage (0x033F). This DTC is set
when the voltage on the fuel
temperature sensor circuit is greater than
that expected by the engine control
module. Refer to the electrical circuit
diagrams and check the fuel temperature
sensor signal and ground circuits for
short circuit to power, open circuit or
high resistance. Repair harness as
required. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Check and install new fuel temperature
sensor as required

P0191- Fuel Rail Pressure Sensor The engine control Using the Jaguar Land Rover approved
16 A Circuit module measured a diagnostic system, check datalogger
Range/Performance - voltage below a signals, Fuel Rail Pressure Sensor
Circuit voltage below specified range but not (0x0324), Fuel Rail Pressure (0xF423).
threshold necessarily a short The fuel rail pressure sensor is a
circuit to ground pressure transducer mounted on the fuel
Fuel supply system rail. This DTC is set when the voltage
failure on the signal line is less than that
Harness failure - Fuel expected by the engine control module.
rail pressure sensor Refer to the workshop manual and
circuit failure ensure that the fuel supply system is
Sensor component working correctly
failure Refer to the electrical circuit diagrams
and check the sensor supply, signal and
ground connections for intermittent
failures, open circuits, short circuits,
high resistance. Repair harness as
required. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Check and install new fuel rail pressure
sensor as required

P0191- Fuel Rail Pressure Sensor The engine control Using the Jaguar Land Rover approved
17 A Circuit module measured a diagnostic system, check datalogger
Range/Performance - voltage above a signals, Fuel Rail Pressure Sensor
Circuit voltage above specified range but not (0x0324), Fuel Rail Pressure (0xF423).
threshold necessarily a short The fuel rail pressure sensor is a
circuit to power pressure transducer mounted on the fuel
Fuel supply system rail. This DTC is set when the voltage
failure on the signal line is greater than that
Harness failure - Fuel expected by the engine control module.
rail pressure sensor Refer to the workshop manual and
circuit failure ensure that the fuel supply system is
Sensor component working correctly
failure Refer to the electrical circuit diagrams
and check the sensor supply, signal and
ground connections for intermittent
failures, open circuits, short circuits,
high resistance. Repair harness as
required. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Check and install new fuel rail pressure
sensor as required

P0192- Fuel Rail Pressure Sensor The engine control Using the Jaguar Land Rover approved
16 A Circuit Low - Circuit module measured a diagnostic system, check datalogger
voltage below threshold voltage below a signals, Fuel Rail Pressure Sensor
specified range but not (0x0324), Fuel Rail Pressure (0xF423).
necessarily a short The fuel rail pressure sensor is a
circuit to ground pressure transducer mounted on the fuel
Fuel supply system rail. This DTC is set when the voltage
failure on the signal line is less than that
Harness failure - Fuel expected by the engine control module.
rail pressure sensor Refer to the workshop manual and
circuit failure ensure that the fuel supply system is
Sensor component working correctly
failure Refer to the electrical circuit diagrams
and check the sensor supply, signal and
ground connections for short circuit to
power, short circuit to ground, open
circuit, high resistance. Repair harness
as required. Using the Jaguar Land
Rover approved diagnostic system, clear
all stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Check and install new fuel rail pressure
sensor as required

P0193- Fuel Rail Pressure Sensor The engine control Using the Jaguar Land Rover approved
17 A Circuit High - Circuit module measured a diagnostic system, check datalogger
voltage above threshold voltage above a signals, Fuel Rail Pressure Sensor
specified range but not (0x0324), Fuel Rail Pressure (0xF423).
necessarily a short The fuel rail pressure sensor is a
circuit to power pressure transducer mounted on the fuel
Fuel supply system rail. This DTC is set when the voltage
failure on the signal line is greater than that
Harness failure - Fuel expected by the engine control module.
rail pressure sensor Refer to the workshop manual and
circuit failure ensure that the fuel supply system is
Sensor component working correctly
failure Refer to the electrical circuit diagrams
and check the sensor supply, signal and
ground connections for short circuit to
power, short circuit to ground, open
circuit, high resistance. Repair harness
as required. Using the Jaguar Land
Rover approved diagnostic system, clear
all stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Check and install new fuel rail pressure
sensor as required

P0194- Fuel Rail Pressure Sensor Fuel supply system Using the Jaguar Land Rover approved
00 A Circuit failure diagnostic system, check datalogger
Intermittent/Erratic - No Harness failure - Fuel signals, Fuel Rail Pressure Sensor
sub type information rail pressure sensor (0x0324), Fuel Rail Pressure (0xF423).
circuit failure The fuel rail pressure sensor is a
Sensor component pressure transducer mounted on the fuel
failure rail. Refer to the workshop manual and
ensure that the fuel supply system is
working correctly
Refer to the electrical circuit diagrams
and check the sensor supply, signal and
ground connections for intermittent
failures, open circuits, short circuits,
high resistance. Repair harness as
required. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Check and install new fuel rail pressure
sensor as required

P0195- Engine Oil Temperature Oil contaminated or Check the oil level is correct and the oil
00 Sensor Circuit - No sub level incorrect does not appear contaminated. Renew or
type information Harness failure - Oil top up oil as required
level and temperature Refer to the electrical circuit diagrams
sensor circuits and check the sensor power and ground
Oil level and supplies for open circuit or short circuit
temperature sensor to ground. Check the signal line for
failure open circuit, short circuit to power,
short circuit to ground, high resistance
and intermittent connections. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new engine oil level
and temperature sensor as required

P0195- Engine Oil Temperature The engine control Check the oil level is correct and the oil
23 Sensor Circuit - Signal module measures a does not appear contaminated. Renew or
stuck low signal that remains top up oil as required
low when transitions Refer to the electrical circuit diagrams
are expected and check the sensor power and ground
Oil contaminated or supplies for open circuit or short circuit
level incorrect to ground. Check the signal line for
Harness failure - Oil open circuit, short circuit to power,
level and temperature short circuit to ground, high resistance
sensor circuits and intermittent connections. Repair
Oil level and harness as required. Using the Jaguar
temperature sensor Land Rover approved diagnostic
failure system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new engine oil level
and temperature sensor as required

P0195- Engine Oil Temperature Oil contaminated or Check the oil does not appear
62 Sensor Circuit - Signal level incorrect contaminated and the level is correct.
compare failure Harness failure - Oil Renew or top up oil as required
level and temperature Refer to the electrical circuit diagrams
sensor circuit short and check oil level and temperature
circuit to ground, short sensor signal circuit for short circuit to
circuit to power, high ground, short circuit to power, high
resistance, open resistance, open circuit, disconnected
circuit, disconnected Start the engine from cold and allow to
Oil level and idle, check and record Sump Oil
temperature sensor Temperature - Measured (0x03F3)
failure datalogger signal. Continue to warm up
at idle, after approximately 10 minutes
check and record Sump Oil Temperature
- Measured (0x03F3) signal. If value of
signal has not increased by 5°C check
and install new oil level and temperature
sensor as required
P0201- Cylinder 1 Injector Harness failure - This DTC is set when the engine control
00 Circuit/Open - No sub type Cylinder 1 injector module detects an open circuit on the
information circuit open circuit cylinder 1 injector control circuit. Refer
Cylinder 1 injector to the electrical circuit diagrams and
failure check the two control circuits between
the engine control module and the fuel
injector for high resistance, open
circuits or intermittent connections.
Repair harness as required.
Check and install new fuel injector as
required

P0202- Cylinder 2 Injector Harness failure - This DTC is set when the engine control
00 Circuit/Open - No sub type Cylinder 2 injector module detects an open circuit on the
information circuit open circuit cylinder 2 injector control circuit. Refer
Cylinder 2 injector to the electrical circuit diagrams and
failure check the two control circuits between
the engine control module and the fuel
injector for high resistance, open
circuits or intermittent connections.
Repair harness as required
Check and install new fuel injector as
required

P0203- Cylinder 3 Injector Harness failure - This DTC is set when the engine control
00 Circuit/Open - No sub type Cylinder 3 injector module detects an open circuit on the
information circuit open circuit cylinder 3 injector control circuit. Refer
Cylinder 3 injector to the electrical circuit diagrams and
failure check the two control circuits between
the engine control module and the fuel
injector for high resistance, open
circuits or intermittent connections.
Repair harness as required
Check and install new fuel injector as
required

P0204- Cylinder 4 Injector Harness failure - This DTC is set when the engine control
00 Circuit/Open - No sub type Cylinder 4 injector module detects an open circuit on the
information circuit open circuit cylinder 4 injector control circuit. Refer
Cylinder 4 injector to the electrical circuit diagrams and
failure check the two control circuits between
the engine control module and the fuel
injector for high resistance, open
circuits or intermittent connections.
Repair harness as required
Check and install new fuel injector as
required

P0205- Cylinder 5 Injector Harness failure - This DTC is set when the engine control
00 Circuit/Open - No sub type Cylinder 5 injector module detects an open circuit on the
information circuit open circuit cylinder 5 injector control circuit. Refer
Cylinder 5 injector to the electrical circuit diagrams and
failure check the two control circuits between
the engine control module and the fuel
injector for high resistance, open
circuits or intermittent connections.
Repair harness as required
Check and install new fuel injector as
required

P0206- Cylinder 6 Injector Harness failure - This DTC is set when the engine control
00 Circuit/Open - No sub type Cylinder 6 injector module detects an open circuit on the
information circuit open circuit cylinder 6 injector control circuit. Refer
Cylinder 6 injector to the electrical circuit diagrams and
failure check the two control circuits between
the engine control module and the fuel
injector for high resistance, open
circuits or intermittent connections.
Repair harness as required
Check and install new fuel injector as
required

P0216- Injector/Injection timing Internal engine control Refer to the workshop manual and the
00 Control Circuit - No sub module power supply battery care manual, inspect the vehicle
type information is unable to supply the battery and ensure it is fully charged and
fuel injectors with the serviceable before performing further
maximum number of tests
injections required Check the vehicle charging system
Internal engine control performance to ensure the voltage
module monitoring regulation is correct
has detected a fuel Refer to the electrical circuit diagrams
pressure not able to and check engine control module power
meet the demand for and ground circuits
the number of fuel Check fuel control system for related
injections DTCs and refer to the relevant DTC
At high engine speeds index
the internal engine Using the Jaguar Land Rover approved
control module diagnostic system, clear all stored DTCs
monitoring has using the ‘Diagnosis Menu’ tab and
detected that the retest
computing time
available for the
desired number of
injections is not
sufficient

P0219- Engine Overspeed Camshaft or Refer to the electrical circuit diagrams


00 Condition - No sub type crankshaft position and check camshaft and crankshaft
information sensor circuit short position sensor circuits for short circuit
circuit to ground, short to ground, short circuit to power, open
circuit to power, open circuit
circuit Check for engine oil ingestion to
Camshaft or sensors. Check and install new camshaft
crankshaft position and crankshaft position sensor as
sensor failure required

P0235- Turbocharger/Supercharger The engine control Using the Jaguar Land Rover approved
16 Boost Sensor A Circuit - module measured a diagnostic system, check datalogger
Circuit voltage below voltage below a signals, Turbocharger/Supercharger
threshold specified range but not Boost Sensor A Circuit (0x033C), Boost
necessarily a short Absolute Pressure - Raw Value
circuit to ground (0x033E). This DTC is set when the
Mechanical failure - engine control module detects a signal
Sensor hose blocked voltage from the boost air pressure
or leaking sensor signal line which is less than the
Failure affecting threshold value. Check the sensor hose
intake air circuit or for blockages or leaks
boost air circuit Using the Jaguar Land Rover approved
control valves or diagnostic system, perform routine -
actuators Inline diagnostic unit 2 diagnostic test -
Harness failure - Boost Turbocharger
air pressure sensor Check the intake air and boost air
circuit circuits for failures including leaks,
Boost air pressure blockages, control valve actuator
sensor failure malfunctions
Refer to the electrical circuit diagrams
and check the sensor power and ground
supplies for open circuit or short circuit
to ground. Check the signal line for
open circuit, short circuit to ground,
high resistance and intermittent
connections. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new boost air pressure
sensor as required

P0235- Turbocharger/Supercharger The engine control Using the Jaguar Land Rover approved
17 Boost Sensor A Circuit - module measured a diagnostic system, check datalogger
Circuit voltage above voltage above a signals, Turbocharger/Supercharger
threshold specified range but not Boost Sensor A Circuit (0x033C), Boost
necessarily a short Absolute Pressure - Raw Value
circuit to power (0x033E). This DTC is set when the
Mechanical failure - engine control module detects a signal
Sensor hose blocked voltage from the boost air pressure
or leaking sensor signal line which is greater than
Failure affecting the threshold value. Check the sensor
intake air circuit or hose for blockages or leaks
boost air circuit Using the Jaguar Land Rover approved
control valves or diagnostic system, perform routine -
actuators Inline diagnostic unit 2 diagnostic test -
Harness failure - Boost Turbocharger
air pressure sensor Check the intake air and boost air
circuit circuits for failures including leaks,
Boost air pressure blockages, control valve actuator
sensor failure malfunctions
Refer to the electrical circuit diagrams
and check the sensor power and ground
supplies for open circuit or short circuit
to ground. Check the signal line for
open circuit, short circuit to power.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new boost air pressure
sensor as required

P0235- Turbocharger/Supercharger The engine control If this DTC is logged with P00BD-07
94 Boost Sensor A Circuit - module has detected suspect, boost air solenoid stuck open
Unexpected operation that the component is mono turbo mode
operating in a way or If this DTC is logged with P00BD-07
at a time that it has not suspect, turbine intake solenoid leakage
been commanded to when closed
operate If this DTC is logged with P00BD-07,
Charge air shut-off P22D2-77, P1247-00 & P22CF-71
valve is stuck open suspect, turbine intake solenoid stuck
Turbine intake shut- open
off valve Check the vacuum system, Charge air
shut-off valve and Turbine intake shut-
off valve operation. Refer to section
303-04B or 303-04D and perform
pinpoint test A Vacuum Control System
Tests
If this DTC is logged with P00BD-07,
P22D2-77, P1247-00 & P22CF-71
suspect, intake air system, blocked low
pressure air intake
Using the Jaguar Land Rover Approved
Diagnostic Equipment, perform the
(Turbo, EGR and air path dynamic test)
routine
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Turbocharger

P023D- Manifold Absolute Induction system air Check induction system for leaks,
00 Pressure- leak or blockage blockages
Turbocharger/Supercharger Boost air system leak Check boost air system for leaks,
Boost Sensor A or blockage blockages. Check for related DTCs and
Correlation - No sub type Manifold absolute refer to the relevant DTC index
information pressure sensor A Check and install new manifold absolute
failure pressure sensor as required
Variable geometry Check and install new variable
turbocharger actuator geometry turbocharger actuator as
A sticking, failure required
Turbocharger A Check turbocharger rod connection and
failure oil seals

P0251- Injection Pump Fuel The engine control Using the Jaguar Land Rover approved
13 Metering Control A - module has diagnostic system, check datalogger
Circuit open determined an open signals, Fuel Volume Control Valve
circuit via lack of bias Duty Cycle (0x03C2), Fuel Volume
voltage, low current Control Valve Current - Measured
flow, no change in the (0x03EA). Refer to the electrical circuit
state of an input in diagrams and check the fuel volume
response to an output control valve circuit between the engine
Harness failure - Fuel control module and the fuel volume
volume control valve control valve for open circuit. Check
circuit open circuit power supply to fuel volume control
Fuel volume control valve. Repair harness as required. Using
valve failure the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new fuel volume
control valve as required

P0251- Injection Pump Fuel Harness failure - Fuel Using the Jaguar Land Rover approved
4B Metering Control A - Over volume control valve diagnostic system, check datalogger
temperature circuit short circuit to signals, Fuel Volume Control Valve
ground, short circuit to Duty Cycle (0x03C2), Fuel Volume
power, high resistance Control Valve Current - Measured
Fuel volume control (0x03EA). Refer to the electrical circuit
valve failure diagrams and check the fuel volume
control valve circuit between the engine
control module and the fuel volume
control valve for short circuit to ground,
short circuit to power, high resistance.
Check power supply to fuel volume
control valve. Repair harness as
required. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Check and install new fuel volume
control valve as required

P0252- Injection Pump Fuel The engine control Using the Jaguar Land Rover approved
16 Metering Control A module measured a diagnostic system, check datalogger
Range/Performance - voltage below a signals, Fuel Volume Control Valve
Circuit voltage below specified range but not Duty Cycle (0x03C2), Fuel Volume
threshold necessarily a short Control Valve Current - Measured
circuit to ground (0x03EA). This DTC is set when the
Harness failure - Fuel voltage on the signal circuit to the fuel
volume control valve volume control valve is less than that
circuit expected by the engine control module.
Fuel volume control Refer to the electrical circuit diagrams
valve failure and check the fuel volume control valve
circuit between the engine control
module and the fuel volume control
valve for an intermittent open circuit,
high resistance, short circuit to ground.
Check the power supply to fuel volume
control valve. Repair harness as
required. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Check and install new fuel volume
control valve as required

P0252- Injection Pump Fuel The engine control Using the Jaguar Land Rover approved
17 Metering Control A module measured a diagnostic system, check datalogger
Range/Performance - voltage above a signals, Fuel Volume Control Valve
Circuit voltage above specified range but not Duty Cycle (0x03C2), Fuel Volume
threshold necessarily a short Control Valve Current - Measured
circuit to power (0x03EA). This DTC is set when the
Harness failure - Fuel voltage on the signal circuit to the fuel
volume control valve volume control valve is greater than that
circuit expected by the engine control module.
Fuel volume control Refer to the electrical circuit diagrams
valve failure and check the fuel volume control valve
circuit between the engine control
module and the volume control valve
for a short circuit to power. Check the
power supply to fuel volume control
valve. Repair harness as required. Using
the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new fuel volume
control valve as required

P0253- Injection Pump Fuel Harness failure - Fuel Using the Jaguar Land Rover approved
00 Metering Control A Low - volume control valve diagnostic system, check datalogger
No sub type information circuit short circuit to signals, Fuel Volume Control Valve
ground, open circuit Duty Cycle (0x03C2), Fuel Volume
Fuel volume control Control Valve Current - Measured
valve failure (0x03EA). This DTC is set when the
voltage on the signal circuit to the fuel
volume control valve is less than that
expected by the engine control module.
Refer to the electrical circuit diagrams
and check the fuel volume control valve
circuit between the engine control
module and the fuel volume control
valve for a short circuit to ground, open
circuit. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new fuel volume
control valve as required

P0254- Injection Pump Fuel Harness failure - Fuel Using the Jaguar Land Rover approved
00 Metering Control A High - volume control valve diagnostic system, check datalogger
No sub type information circuit short circuit to signals, Fuel Volume Control Valve
power Duty Cycle (0x03C2), Fuel Volume
Fuel volume control Control Valve Current - Measured
valve failure (0x03EA). This DTC is set when the
voltage on the signal circuit to the fuel
volume control valve is greater than that
expected by the engine control module.
Refer to the electrical circuit diagrams
and check the fuel volume control valve
circuit between the engine control
module and the fuel volume control
valve for a short circuit to power. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new fuel volume
control valve as required

P0255- Injection Pump Fuel Harness failure - Fuel Using the Jaguar Land Rover approved
00 Metering Control A volume control valve diagnostic system, check datalogger
Intermittent - No sub type circuit intermittent signals, Fuel Volume Control Valve
information short circuit to ground, Duty Cycle (0x03C2), Fuel Volume
short circuit to power, Control Valve Current - Measured
high resistance (0x03EA). Refer to the electrical circuit
Fuel volume control diagrams and check the fuel volume
valve intermittent control valve circuit between the engine
failure control module and the fuel volume
control valve for an intermittent short
circuit to ground, short circuit to power,
high resistance. Repair harness as
required. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Check and install new fuel volume
control valve as required

P0261- Cylinder 1 Injector Circuit Harness failure - Refer to the electrical circuit diagrams
00 Low - No sub type Injector control circuit and check the injector control circuit
information short circuit between the engine control module and
Injector failure the cylinder 1 injector for short circuit to
ground or short between the two wires.
This circuit is a twisted pair, check both
high and low sides for short circuit to
power. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new fuel injector as
required

P0261- Cylinder 1 Injector Circuit The engine control Refer to the electrical circuit diagrams
11 Low - Circuit short to module has detected a and check the injector control circuit
ground ground measurement between the engine control module and
for a period longer the cylinder 1 injector for short circuit to
than expected or has ground or short between the two wires.
detected a ground This circuit is a twisted pair, check both
measurement when high and low sides for short circuit to
another value was ground. Repair harness as required.
expected Using the Jaguar Land Rover approved
Harness failure - diagnostic system, clear all stored DTCs
Injector control circuit using the ‘Diagnosis Menu’ tab and
short circuit to ground retest
Check and install new fuel injector as
required

P0261- Cylinder 1 Injector Circuit The engine control Refer to the electrical circuit diagrams
23 Low - Signal stuck low module measures a and check the injector control circuits
signal that remains between the engine control module and
low when transitions the cylinder 1 injector for short circuit to
are expected other injector control circuits. Repair
Harness failure - Short harness as required. Using the Jaguar
circuit between Land Rover approved diagnostic
injector control system, clear all stored DTCs using the
circuits on different ‘Diagnosis Menu’ tab and retest
cylinders

P0264- Cylinder 2 Injector Circuit Harness failure - Refer to the electrical circuit diagrams
00 Low - No sub type Injector control circuit and check the injector control circuit
information short circuit between the engine control module and
Injector failure the cylinder 2 injector for short circuit to
ground or short between the two wires.
This circuit is a twisted pair, check both
high and low sides for short circuit to
power. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new fuel injector as
required

P0264- Cylinder 2 Injector Circuit The engine control Refer to the electrical circuit diagrams
11 Low - Circuit short to module has detected a and check the injector control circuit
ground ground measurement between the engine control module and
for a period longer the cylinder 2 injector for short circuit to
than expected or has ground or short between the two wires.
detected a ground This circuit is a twisted pair, check both
measurement when high and low sides for short circuit to
another value was ground. Repair harness as required.
expected Using the Jaguar Land Rover approved
Harness failure - diagnostic system, clear all stored DTCs
Injector control circuit using the ‘Diagnosis Menu’ tab and
short circuit to ground retest
Check and install new fuel injector as
required

P0264- Cylinder 2 Injector Circuit The engine control Refer to the electrical circuit diagrams
23 Low - Signal stuck low module measures a and check the injector control circuits
signal that remains between the engine control module and
low when transitions the cylinder 2 injector for short circuit to
are expected other injector control circuits. Repair
Harness failure - Short harness as required. Using the Jaguar
circuit between Land Rover approved diagnostic
injector control system, clear all stored DTCs using the
circuits on different ‘Diagnosis Menu’ tab and retest
cylinders

P0267- Cylinder 3 Injector Circuit Harness failure - Refer to the electrical circuit diagrams
00 Low - No sub type Injector control circuit and check the injector control circuit
information short circuit between the engine control module and
Injector failure the cylinder 3 injector for short circuit to
ground or short between the two wires.
This circuit is a twisted pair, check both
high and low sides for short circuit to
power. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new fuel injector as
required

P0267- Cylinder 3 Injector Circuit The engine control Refer to the electrical circuit diagrams
11 Low - Circuit short to module has detected a and check the injector control circuit
ground ground measurement between the engine control module and
for a period longer the cylinder 3 injector for short circuit to
than expected or has ground or short between the two wires.
detected a ground This circuit is a twisted pair, check both
measurement when high and low sides for short circuit to
another value was ground. Repair harness as required.
expected Using the Jaguar Land Rover approved
Harness failure - diagnostic system, clear all stored DTCs
Injector control circuit using the ‘Diagnosis Menu’ tab and
short circuit to ground retest
Check and install new fuel injector as
required

P0267- Cylinder 3 Injector Circuit The engine control Refer to the electrical circuit diagrams
23 Low - Signal stuck low module measures a and check the injector control circuits
signal that remains between the engine control module and
low when transitions the cylinder 3 injector for short circuit to
are expected other injector control circuits. Repair
Harness failure - Short harness as required. Using the Jaguar
circuit between Land Rover approved diagnostic
injector control system, clear all stored DTCs using the
circuits on different ‘Diagnosis Menu’ tab and retest
cylinders

P0270- Cylinder 4 Injector Circuit Harness failure - Refer to the electrical circuit diagrams
00 Low - No sub type Injector control circuit and check the injector control circuit
information short circuit between the engine control module and
Injector failure the cylinder 4 injector for short circuit to
ground or short between the two wires.
This circuit is a twisted pair, check both
high and low sides for short circuit to
power. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new fuel injector as
required

P0270- Cylinder 4 Injector Circuit The engine control Refer to the electrical circuit diagrams
11 Low - Circuit short to module has detected a and check the injector control circuit
ground ground measurement between the engine control module and
for a period longer the cylinder 4 injector for short circuit to
than expected or has ground or short between the two wires.
detected a ground This circuit is a twisted pair, check both
measurement when high and low sides for short circuit to
another value was ground. Repair harness as required.
expected Using the Jaguar Land Rover approved
Harness failure - diagnostic system, clear all stored DTCs
Injector control circuit using the ‘Diagnosis Menu’ tab and
short circuit to ground retest
Check and install new fuel injector as
required

P0270- Cylinder 4 Injector Circuit The engine control Refer to the electrical circuit diagrams
23 Low - Signal stuck low module measures a and check the injector control circuits
signal that remains between the engine control module and
low when transitions the cylinder 4 injector for short circuit to
are expected other injector control circuits. Repair
Harness failure - Short harness as required. Using the Jaguar
circuit between Land Rover approved diagnostic
injector control system, clear all stored DTCs using the
circuits on different ‘Diagnosis Menu’ tab and retest
cylinders

P0273- Cylinder 5 Injector Circuit Harness failure - Refer to the electrical circuit diagrams
00 Low - No sub type Injector control circuit and check the injector control circuit
information short circuit between the engine control module and
Injector failure the cylinder 5 injector for short circuit to
ground or short between the two wires.
This circuit is a twisted pair, check both
high and low sides for short circuit to
power. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new fuel injector as
required

P0273- Cylinder 5 Injector Circuit The engine control Refer to the electrical circuit diagrams
11 Low - Circuit short to module has detected a and check the injector control circuit
ground ground measurement between the engine control module and
for a period longer the cylinder 5 injector for short circuit to
than expected or has ground or short between the two wires.
detected a ground This circuit is a twisted pair, check both
measurement when high and low sides for short circuit to
another value was ground. Repair harness as required.
expected Using the Jaguar Land Rover approved
Harness failure - diagnostic system, clear all stored DTCs
Injector control circuit using the ‘Diagnosis Menu’ tab and
short circuit to ground retest
Check and install new fuel injector as
required

P0273- Cylinder 5 Injector Circuit The engine control Refer to the electrical circuit diagrams
23 Low - Signal stuck low module measures a and check the injector control circuits
signal that remains between the engine control module and
low when transitions the cylinder 5 injector for short circuit to
are expected other injector control circuits. Repair
Harness failure - Short harness as required. Using the Jaguar
circuit between Land Rover approved diagnostic
injector control system, clear all stored DTCs using the
circuits on different ‘Diagnosis Menu’ tab and retest
cylinders

P0276- Cylinder 6 Injector Circuit Harness failure - Refer to the electrical circuit diagrams
00 Low - No sub type Injector control circuit and check the injector control circuit
information short circuit between the engine control module and
Injector failure the cylinder 6 injector for short circuit to
ground or short between the two wires.
This circuit is a twisted pair, check both
high and low sides for short circuit to
power. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new fuel injector as
required

P0276- Cylinder 6 Injector Circuit The engine control Refer to the electrical circuit diagrams
11 Low - Circuit short to module has detected a and check the injector control circuit
ground ground measurement between the engine control module and
for a period longer the cylinder 6 injector for short circuit to
than expected or has ground or short between the two wires.
detected a ground This circuit is a twisted pair, check both
measurement when high and low sides for short circuit to
another value was ground. Repair harness as required.
expected Using the Jaguar Land Rover approved
Harness failure - diagnostic system, clear all stored DTCs
Injector control circuit using the ‘Diagnosis Menu’ tab and
short circuit to ground retest
Check and install new fuel injector as
required

P0276- Cylinder 6 Injector Circuit The engine control Refer to the electrical circuit diagrams
23 Low - Signal Stuck Low module measures a and check the injector control circuits
signal that remains between the engine control module and
low when transitions the cylinder 6 injector for short circuit to
are expected other injector control circuits. Repair
Harness failure - Short harness as required. Using the Jaguar
circuit between Land Rover approved diagnostic
injector control system, clear all stored DTCs using the
circuits on different ‘Diagnosis Menu’ tab and retest
cylinders

P02CD- Cylinder 1 Fuel Injector Corrected set point Check for other related DTCs and refer
00 Offset Learning at Max voltage of the piezo to the relevant DTC index. Using the
Limit - No sub type actuator violates the Jaguar Land Rover approved diagnostic
information on board diagnostic system, clear all stored DTCs using the
limit ‘Diagnosis Menu’ tab and retest
Fuel injector internal Check and install new a fuel injector as
components out of required
tolerance

P02CF- Cylinder 2 Fuel Injector Corrected set point Check for other related DTCs and refer
00 Offset Learning at Max voltage of the piezo to the relevant DTC index. Using the
Limit - No sub type actuator violates the Jaguar Land Rover approved diagnostic
information on board diagnostic system, clear all stored DTCs using the
limit ‘Diagnosis Menu’ tab and retest
Fuel injector internal Check and install new a fuel injector as
components out of required
tolerance

P02D1- Cylinder 3 Fuel Injector Corrected set point Check for other related DTCs and refer
00 Offset Learning at Max voltage of the piezo to the relevant DTC index. Using the
Limit - No sub type actuator violates the Jaguar Land Rover approved diagnostic
information on board diagnostic system, clear all stored DTCs using the
limit ‘Diagnosis Menu’ tab and retest
Fuel injector internal Check and install new a fuel injector as
components out of required
tolerance

P02D3- Cylinder 4 Fuel Injector Corrected set point Check for other related DTCs and refer
00 Offset Learning at Max voltage of the piezo to the relevant DTC index. Using the
Limit - No sub type actuator violates the Jaguar Land Rover approved diagnostic
information on board diagnostic system, clear all stored DTCs using the
limit ‘Diagnosis Menu’ tab and retest
Fuel injector internal Check and install new a fuel injector as
components out of required
tolerance

P02D5- Cylinder 5 Fuel Injector Corrected set point Check for other related DTCs and refer
00 Offset Learning at Max voltage of the piezo to the relevant DTC index. Using the
Limit - No sub type actuator violates the Jaguar Land Rover approved diagnostic
information on board diagnostic system, clear all stored DTCs using the
limit ‘Diagnosis Menu’ tab and retest
Fuel injector internal Check and install new a fuel injector as
components out of required
tolerance

P02D7- Cylinder 6 Fuel Injector Corrected set point Check for other related DTCs and refer
00 Offset Learning at Max voltage of the piezo to the relevant DTC index. Using the
Limit - No sub type actuator violates the Jaguar Land Rover approved diagnostic
information on board diagnostic system, clear all stored DTCs using the
limit ‘Diagnosis Menu’ tab and retest
Fuel injector internal Check and install new a fuel injector as
components out of required
tolerance

P02EE- Cylinder 1 Injector Circuit The engine control This DTC is set when the engine control
17 Range/Performance - module measured a module monitors a voltage on the
Circuit voltage above voltage above a cylinder 1 injector control circuit that is
threshold specified range but not above the diagnostic threshold. The
necessarily a short injector control circuit consists of a
circuit to power twisted pair of wires between the engine
Harness failure - control module and the Piezo actuator
Injector control circuit within the injector. Refer to the
Fuel injector failure electrical circuit diagrams and check
both the control circuits (high and low)
for open circuit, short circuit to ground,
short circuit to power, intermittent
connections, high resistance, short to or
interference from other circuits. Repair
wiring harness as required
Check and install new a fuel injector as
required

P02EE- Cylinder 1 Injector Circuit The engine control This DTC is set when the engine control
1C Range/Performance - module measured a module monitors a voltage on the
Circuit voltage out of range voltage outside of the cylinder 1 injector control circuit that is
expected range, but out of range. The injector control circuit
not identified as too consists of a twisted pair of wires
high or too low between the engine control module and
Harness failure - the Piezo actuator within the injector.
Injector control circuit Refer to the electrical circuit diagrams
Fuel injector failure and check both the control circuits (high
and low) for open circuit, short circuit to
ground, short circuit to power,
intermittent connections, high
resistance, short to or interference from
other circuits. Repair wiring harness as
required
Check and install new a fuel injector as
required

P02EE- Cylinder 1 Injector Circuit Harness failure - This DTC is set when the engine control
68 Range/Performance - Injector control circuit module monitors a voltage on the
Event information Fuel injector failure cylinder 1 injector control circuit that is
out of range. The injector control circuit
consists of a twisted pair of wires
between the engine control module and
the Piezo actuator within the injector.
Refer to the electrical circuit diagrams
and check both the control circuits (high
and low) for open circuit, short circuit to
ground, short circuit to power,
intermittent connections, high
resistance, short to or interference from
other circuits. Repair wiring harness as
required
Check and install new a fuel injector as
required

P02EF- Cylinder 2 Injector Circuit The engine control This DTC is set when the engine control
17 Range/Performance - module measured a module monitors a voltage on the
Circuit voltage above voltage above a cylinder 2 injector control circuit that is
threshold specified range but not above the diagnostic threshold. The
necessarily a short injector control circuit consists of a
circuit to power twisted pair of wires between the engine
Harness failure - control module and the Piezo actuator
Injector control circuit within the injector. Refer to the
Fuel injector failure electrical circuit diagrams and check
both the control circuits (high and low)
for open circuit, short circuit to ground,
short circuit to power, intermittent
connections, high resistance, short to or
interference from other circuits. Repair
wiring harness as required
Check and install new a fuel injector as
required
P02EF- Cylinder 2 Injector Circuit The engine control This DTC is set when the engine control
1C Range/Performance - module measured a module monitors a voltage on the
Circuit voltage out of range voltage outside of the cylinder 2 injector control circuit that is
expected range, but out of range. The injector control circuit
not identified as too consists of a twisted pair of wires
high or too low between the engine control module and
Harness failure - the Piezo actuator within the injector.
Injector control circuit Refer to the electrical circuit diagrams
Fuel injector failure and check both the control circuits (high
and low) for open circuit, short circuit to
ground, short circuit to power,
intermittent connections, high
resistance, short to or interference from
other circuits. Repair wiring harness as
required
Check and install new a fuel injector as
required

P02EF- Cylinder 2 Injector Circuit Harness failure - This DTC is set when the engine control
68 Range/Performance - Injector control circuit module monitors a voltage on the
Event information Fuel injector failure cylinder 2 injector control circuit that is
out of range. The injector control circuit
consists of a twisted pair of wires
between the engine control module and
the Piezo actuator within the injector.
Refer to the electrical circuit diagrams
and check both the control circuits (high
and low) for open circuit, short circuit to
ground, short circuit to power,
intermittent connections, high
resistance, short to or interference from
other circuits. Repair wiring harness as
required
Check and install new a fuel injector as
required

P02F0- Cylinder 3 Injector Circuit The engine control This DTC is set when the engine control
17 Range/Performance - module measured a module monitors a voltage on the
Circuit voltage above voltage above a cylinder 3 injector control circuit that is
threshold specified range but not above the diagnostic threshold. The
necessarily a short injector control circuit consists of a
circuit to power twisted pair of wires between the engine
Harness failure - control module and the Piezo actuator
Injector control circuit within the injector. Refer to the
Fuel injector failure electrical circuit diagrams and check
both the control circuits (high and low)
for open circuit, short circuit to ground,
short circuit to power, intermittent
connections, high resistance, short to or
interference from other circuits. Repair
wiring harness as required
Check and install new a fuel injector as
required

P02F0- Cylinder 3 Injector Circuit The engine control This DTC is set when the engine control
1C Range/Performance - module measured a module monitors a voltage on the
Circuit voltage out of range voltage outside of the cylinder 3 injector control circuit that is
expected range, but out of range. The injector control circuit
not identified as too consists of a twisted pair of wires
high or too low between the engine control module and
Harness failure - the Piezo actuator within the injector.
Injector control circuit Refer to the electrical circuit diagrams
Fuel injector failure and check both the control circuits (high
and low) for open circuit, short circuit to
ground, short circuit to power,
intermittent connections, high
resistance, short to or interference from
other circuits. Repair wiring harness as
required
Check and install new a fuel injector as
required

P02F0- Cylinder 3 Injector Circuit Harness failure - This DTC is set when the engine control
68 Range/Performance - Injector control circuit module monitors a voltage on the
Event information Fuel injector failure cylinder 3 injector control circuit that is
out of range. The injector control circuit
consists of a twisted pair of wires
between the engine control module and
the Piezo actuator within the injector.
Refer to the electrical circuit diagrams
and check both the control circuits (high
and low) for open circuit, short circuit to
ground, short circuit to power,
intermittent connections, high
resistance, short to or interference from
other circuits. Repair wiring harness as
required
Check and install new a fuel injector as
required

P02F1- Cylinder 4 Injector Circuit The engine control This DTC is set when the engine control
17 Range/Performance - module measured a module monitors a voltage on the
Circuit voltage above voltage above a cylinder 4 injector control circuit that is
threshold specified range but not above the diagnostic threshold. The
necessarily a short injector control circuit consists of a
circuit to power twisted pair of wires between the engine
Harness failure - control module and the Piezo actuator
Injector control circuit within the injector. Refer to the
Fuel injector failure electrical circuit diagrams and check
both the control circuits (high and low)
for open circuit, short circuit to ground,
short circuit to power, intermittent
connections, high resistance, short to or
interference from other circuits. Repair
wiring harness as required
Check and install new a fuel injector as
required

P02F1- Cylinder 4 Injector Circuit The engine control This DTC is set when the engine control
1C Range/Performance - module measured a module monitors a voltage on the
Circuit voltage out of range voltage outside of the cylinder 4 injector control circuit that is
expected range, but out of range. The injector control circuit
not identified as too consists of a twisted pair of wires
high or too low between the engine control module and
Harness failure - the Piezo actuator within the injector.
Injector control circuit Refer to the electrical circuit diagrams
Fuel injector failure and check both the control circuits (high
and low) for open circuit, short circuit to
ground, short circuit to power,
intermittent connections, high
resistance, short to or interference from
other circuits. Repair wiring harness as
required
Check and install new a fuel injector as
required

P02F1- Cylinder 4 Injector Circuit Harness failure - This DTC is set when the engine control
68 Range/Performance - Injector control circuit module monitors a voltage on the
Event information Fuel injector failure cylinder 4 injector control circuit that is
out of range. The injector control circuit
consists of a twisted pair of wires
between the engine control module and
the Piezo actuator within the injector.
Refer to the electrical circuit diagrams
and check both the control circuits (high
and low) for open circuit, short circuit to
ground, short circuit to power,
intermittent connections, high
resistance, short to or interference from
other circuits. Repair wiring harness as
required
Check and install new a fuel injector as
required

P02F2- Cylinder 5 Injector Circuit The engine control This DTC is set when the engine control
17 Range/Performance - module measured a module monitors a voltage on the
Circuit voltage above voltage above a cylinder 5 injector control circuit that is
threshold specified range but not above the diagnostic threshold. The
necessarily a short injector control circuit consists of a
circuit to power twisted pair of wires between the engine
Harness failure - control module and the Piezo actuator
Injector control circuit within the injector. Refer to the
Fuel injector failure electrical circuit diagrams and check
both the control circuits (high and low)
for open circuit, short circuit to ground,
short circuit to power, intermittent
connections, high resistance, short to or
interference from other circuits. Repair
wiring harness as required
Check and install new a fuel injector as
required

P02F2- Cylinder 5 Injector Circuit The engine control This DTC is set when the engine control
1C Range/Performance - module measured a module monitors a voltage on the
Circuit voltage out of range voltage outside of the cylinder 5 injector control circuit that is
expected range, but out of range. The injector control circuit
not identified as too consists of a twisted pair of wires
high or too low between the engine control module and
Harness failure - the Piezo actuator within the injector.
Injector control circuit Refer to the electrical circuit diagrams
Fuel injector failure and check both the control circuits (high
and low) for open circuit, short circuit to
ground, short circuit to power,
intermittent connections, high
resistance, short to or interference from
other circuits. Repair wiring harness as
required
Check and install new a fuel injector as
required

P02F2- Cylinder 5 Injector Circuit Harness failure - This DTC is set when the engine control
68 Range/Performance - Injector control circuit module monitors a voltage on the
Event information Fuel injector failure cylinder 5 injector control circuit that is
out of range. The injector control circuit
consists of a twisted pair of wires
between the engine control module and
the Piezo actuator within the injector.
Refer to the electrical circuit diagrams
and check both the control circuits (high
and low) for open circuit, short circuit to
ground, short circuit to power,
intermittent connections, high
resistance, short to or interference from
other circuits. Repair wiring harness as
required
Check and install new a fuel injector as
required

P02F3- Cylinder 6 Injector Circuit The engine control This DTC is set when the engine control
17 Range/Performance - module measured a module monitors a voltage on the
Circuit voltage above voltage above a cylinder 6 injector control circuit that is
threshold specified range but not above the diagnostic threshold. The
necessarily a short injector control circuit consists of a
circuit to power twisted pair of wires between the engine
Harness failure - control module and the Piezo actuator
Injector control circuit within the injector. Refer to the
Fuel injector failure electrical circuit diagrams and check
both the control circuits (high and low)
for open circuit, short circuit to ground,
short circuit to power, intermittent
connections, high resistance, short to or
interference from other circuits. Repair
wiring harness as required
Check and install new a fuel injector as
required

P02F3- Cylinder 6 Injector Circuit The engine control This DTC is set when the engine control
1C Range/Performance - module measured a module monitors a voltage on the
Circuit voltage out of range voltage outside of the cylinder 6 injector control circuit that is
expected range, but out of range. The injector control circuit
not identified as too consists of a twisted pair of wires
high or too low between the engine control module and
Harness failure - the Piezo actuator within the injector.
Injector control circuit Refer to the electrical circuit diagrams
Fuel injector failure and check both the control circuits (high
and low) for open circuit, short circuit to
ground, short circuit to power,
intermittent connections, high
resistance, short to or interference from
other circuits. Repair wiring harness as
required
Check and install new a fuel injector as
required

P02F3- Cylinder 6 Injector Circuit Harness failure - This DTC is set when the engine control
68 Range/Performance - Injector control circuit module monitors a voltage on the
Event information Fuel injector failure cylinder 6 injector control circuit that is
out of range. The injector control circuit
consists of a twisted pair of wires
between the engine control module and
the Piezo actuator within the injector.
Refer to the electrical circuit diagrams
and check both the control circuits (high
and low) for open circuit, short circuit to
ground, short circuit to power,
intermittent connections, high
resistance, short to or interference from
other circuits. Repair wiring harness as
required
Check and install new a fuel injector as
required

P0300- Random Misfire Detected - Fuel injector circuit Check for cylinder mis-fire, glow plug
00 No sub type information failure(s) (injector and injector DTCs and refer to the
DTCs also flagged) relevant DTC index. Refer to the
Fuel system failure electrical circuit diagrams and check
injector circuits for short circuit to
ground, short circuit to power, open
circuit. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check for fuel system failure. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest

P0301- Cylinder 1 Misfire Fuel injector electrical Refer to the electrical circuit diagrams
00 Detected - No sub type circuit failure(s) and check injector circuit for short
information (injector DTCs also circuit to ground, short circuit to power,
flagged) open circuit. Repair harness as required.
Fuel injector failure Using the Jaguar Land Rover approved
Cylinder compression diagnostic system, clear all stored DTCs
low using the ‘Diagnosis Menu’ tab and
retest
Check for cylinder mis-fire, glow plug
and injector DTCs and refer to the
relevant DTC index
Check for fuel injector failure or
blockage. Carry out cylinder
compression tests
P0302- Cylinder 2 Misfire Fuel injector electrical Refer to the electrical circuit diagrams
00 Detected - No sub type circuit failure(s) and check injector circuit for short
information (injector DTCs also circuit to ground, short circuit to power,
flagged) open circuit. Repair harness as required.
Fuel injector failure Using the Jaguar Land Rover approved
Cylinder compression diagnostic system, clear all stored DTCs
low using the ‘Diagnosis Menu’ tab and
retest
Check for cylinder mis-fire, glow plug
and injector DTCs and refer to the
relevant DTC index
Check for fuel injector failure or
blockage. Carry out cylinder
compression tests

P0303- Cylinder 3 Misfire Fuel injector electrical Refer to the electrical circuit diagrams
00 Detected - No sub type circuit failure(s) and check injector circuit for short
information (injector DTCs also circuit to ground, short circuit to power,
flagged) open circuit. Repair harness as required.
Fuel injector failure Using the Jaguar Land Rover approved
Cylinder compression diagnostic system, clear all stored DTCs
low using the ‘Diagnosis Menu’ tab and
retest
Check for cylinder mis-fire, glow plug
and injector DTCs and refer to the
relevant DTC index
Check for fuel injector failure or
blockage. Carry out cylinder
compression tests

P0304- Cylinder 4 Misfire Fuel injector electrical Refer to the electrical circuit diagrams
00 Detected - No sub type circuit failure(s) and check injector circuit for short
information (injector DTCs also circuit to ground, short circuit to power,
flagged) open circuit. Repair harness as required.
Fuel injector failure Using the Jaguar Land Rover approved
Cylinder compression diagnostic system, clear all stored DTCs
low using the ‘Diagnosis Menu’ tab and
retest
Check for cylinder mis-fire, glow plug
and injector DTCs and refer to the
relevant DTC index
Check for fuel injector failure or
blockage. Carry out cylinder
compression tests

P0305- Cylinder 5 Misfire Fuel injector electrical Refer to the electrical circuit diagrams
00 Detected - No sub type circuit failure(s) and check injector circuit for short
information (injector DTCs also circuit to ground, short circuit to power,
flagged) open circuit. Repair harness as required.
Fuel injector failure Using the Jaguar Land Rover approved
Cylinder compression diagnostic system, clear all stored DTCs
low using the ‘Diagnosis Menu’ tab and
retest
Check for cylinder mis-fire, glow plug
and injector DTCs and refer to the
relevant DTC index
Check for fuel injector failure or
blockage. Carry out cylinder
compression tests

P0306- Cylinder 6 Misfire Fuel injector electrical Refer to the electrical circuit diagrams
00 Detected - No sub type circuit failure(s) and check injector circuit for short
information (injector DTCs also circuit to ground, short circuit to power,
flagged) open circuit. Repair harness as required.
Fuel injector failure Using the Jaguar Land Rover approved
Cylinder compression diagnostic system, clear all stored DTCs
low using the ‘Diagnosis Menu’ tab and
retest
Check for cylinder mis-fire, glow plug
and injector DTCs and refer to the
relevant DTC index
Check for fuel injector failure or
blockage. Carry out cylinder
compression tests

P0336- Crankshaft Position Sensor Crankshaft position Refer to the electrical circuit diagrams
29 A Circuit sensor circuit for short and check crankshaft position sensor
Range/Performance - circuit to ground, short circuit for short circuit to ground, short
Signal invalid circuit to power, open circuit to power, open circuit,
circuit, disconnected disconnected. Repair harness as
Crankshaft position required. Using the Jaguar Land Rover
sensor circuit approved diagnostic system, clear all
shielding failure stored DTCs using the ‘Diagnosis
Crankshaft Position Menu’ tab and retest
sensor failure Check and install new crankshaft
Crankshaft position position sensor circuit shielding as
sensor foreign matter required
on sensor face, gap Check crankshaft position sensor for
incorrect foreign matter on crankshaft position
Target wheel failure sensor face. Check crankshaft position
sensor air gap
Check and install new crankshaft
position sensor as required. Check and
install new target wheel as required

P0336- Crankshaft Position Sensor Harness failure - Refer to the electrical circuit diagrams.
31 A Circuit Crankshaft position Check the power supply and ground
Range/Performance - No sensor circuits circuits to the sensor, check the signal
signal Crankshaft position circuit for open circuits, short circuit to
sensor failure power and short circuit to ground.
Crankshaft position Repair harness as required. Using the
sensor or reference Jaguar Land Rover approved diagnostic
target positioning system, clear all stored DTCs using the
incorrect ‘Diagnosis Menu’ tab and retest
Refer to the relevant section of the
workshop manual. Check the sensor and
crankshaft target for damage,
contamination and correct mounting
Check and install new crankshaft
position sensor as required. Check and
install new target wheel as required

P0336- Crankshaft Position Sensor Crankshaft position Refer to the electrical circuit diagrams
64 A Circuit sensor circuit for short and check crankshaft position sensor
Range/Performance - circuit to ground, short circuit for short circuit to ground, short
Signal plausibility failure circuit to power, open circuit to power, open circuit,
circuit, disconnected disconnected. Repair harness as
Crankshaft position required. Using the Jaguar Land Rover
sensor circuit approved diagnostic system, clear all
shielding failure stored DTCs using the ‘Diagnosis
Crankshaft Position Menu’ tab and retest
sensor failure Check and install new crankshaft
Crankshaft position position sensor circuit shielding as
sensor foreign matter required
on sensor face, gap Check crankshaft position sensor for
incorrect foreign matter on crankshaft position
Target wheel failure sensor face. Check crankshaft position
sensor air gap
Check and install new crankshaft
position sensor as required. Check and
install new target wheel as required

P0341- Camshaft Position Sensor Harness failure - Refer to the electrical circuit diagrams.
31 A Circuit Camshaft position Check the power supply and ground
Range/Performance (Bank sensor circuits circuits to the sensor, check the signal
1 or single sensor) - No Camshaft position circuit for open circuit, short circuit to
signal sensor failure power and short circuit to ground.
Camshaft position Repair harness as required. Using the
sensor or reference Jaguar Land Rover approved diagnostic
target positioning system, clear all stored DTCs using the
incorrect ‘Diagnosis Menu’ tab and retest
Refer to the relevant section of the
workshop manual. Check the sensor and
camshaft target for damage,
contamination and correct mounting
Check and install new camshaft position
sensor as required

P0341- Camshaft Position Sensor Harness failure - Refer to the electrical circuit diagrams.
3A A Circuit Camshaft position Check the power supply and ground
Range/Performance (Bank sensor circuits circuits to the sensor, check the signal
1 or single sensor) - Camshaft position circuit for open circuit, short circuit to
Incorrect has too many sensor failure power and short circuit to ground.
pulses Camshaft position Repair harness as required. Using the
sensor or reference Jaguar Land Rover approved diagnostic
target positioning system, clear all stored DTCs using the
incorrect ‘Diagnosis Menu’ tab and retest
Refer to the relevant section of the
workshop manual. Check the sensor and
camshaft target for damage,
contamination and correct mounting.
Check camshaft timing is to
specification
Check and install new camshaft position
sensor as required

P0342- Camshaft Position Sensor Harness failure - Refer to the electrical circuit diagrams.
64 A Circuit Low (Bank 1 or Camshaft position Check the power supply and ground
single sensor) - Signal sensor circuit circuits to the sensor, check the signal
plausibility failure Camshaft position circuit for open circuit, short circuit to
sensor failure power and short circuit to ground.
Camshaft position Repair harness as required. Using the
sensor or reference Jaguar Land Rover approved diagnostic
target positioning system, clear all stored DTCs using the
incorrect ‘Diagnosis Menu’ tab and retest
Check the sensor and camshaft target
for damage, contamination and correct
mounting. Check camshaft timing is to
specification
Check and install new camshaft position
sensor as required

P0380- Glow Plug/Heater Circuit The engine control Using the Jaguar Land Rover approved
11 A - Circuit short to ground module has detected a diagnostic system, check datalogger
ground measurement signal, Glow Plug Coil Duty Cycle
for a period longer (0x9A04). Refer to the electrical circuit
than expected or has diagrams and check the control circuit
detected a ground from the engine control module to the
measurement when glow plug control module for short
another value was circuit to ground. Repair harness as
expected required. Using the Jaguar Land Rover
Harness failure approved diagnostic system, clear all
between engine stored DTCs using the ‘Diagnosis
control module and Menu’ tab and retest
glow plug control Check and install new glow plug control
module - Short circuit module as required
to ground
Component failure -
Glow plug control
module failure

P0380- Glow Plug/Heater Circuit The engine control Using the Jaguar Land Rover approved
12 A - Circuit short to battery module has detected a diagnostic system, check datalogger
vehicle power signal, Glow Plug Coil Duty Cycle
measurement for a (0x9A04). Refer to the electrical circuit
period longer than diagrams and check the control circuit
expected or has from the engine control module to the
detected a vehicle glow plug control module for short
power measurement circuit to power. Repair harness as
when another value required. Using the Jaguar Land Rover
was expected approved diagnostic system, clear all
Harness failure stored DTCs using the ‘Diagnosis
between engine Menu’ tab and retest
control module and Check and install new glow plug control
glow plug control module as required
module - Short circuit
to power
Component failure -
Glow plug control
module failure

P0380- Glow Plug/Heater Circuit The engine control Using the Jaguar Land Rover approved
13 A - Circuit open module has diagnostic system, check datalogger
determined an open signal, Glow Plug Coil Duty Cycle
circuit via lack of bias (0x9A04). Refer to the electrical circuit
voltage, low current diagrams and check the control circuit
flow, no change in the from the engine control module to the
state of an input in glow plug control module for short
response to an output circuit to ground. Repair harness as
Harness failure required. Using the Jaguar Land Rover
between engine approved diagnostic system, clear all
control module and stored DTCs using the ‘Diagnosis
glow plug control Menu’ tab and retest
module - Open circuit Check and install new glow plug control
Component failure - module as required
Glow plug control
module failure

P0380- Glow Plug/Heater Circuit Harness failure - Glow Using the Jaguar Land Rover approved
4B A - Over temperature plug heater circuit A diagnostic system, check datalogger
short circuit to ground, signal, Glow Plug Coil Duty Cycle
short circuit to power, (0x9A04). Refer to the electrical circuit
high resistance diagrams and check the glow plug
heater circuit A for short circuit to
ground, short circuit to power, high
resistance. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest

P0401- Exhaust Gas Recirculation Intake air system, low If this DTC is logged with P00BE-07 &
00 A Flow Insufficient pressure boost leak P006A-00, suspect intake air system,
Detected - No sub type Exhaust gas low pressure boost leak
information recirculation actuator Refer to the electrical circuit diagrams
circuit short circuit to and check exhaust gas recirculation
ground, high actuator circuit for short circuit to
resistance, open ground, high resistance, open circuit,
circuit, disconnected disconnected. Repair harness as
Exhaust gas required. Using the Jaguar Land Rover
recirculation actuator approved diagnostic system, clear all
failure stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new exhaust gas
recirculation actuator as required

P0402- Exhaust Gas Recirculation Intake air system, high If this DTC is logged with P1247-00,
00 A Flow Excessive pressure boost leak P006A-00 & P00BF-07, suspect intake
Detected - No sub type Exhaust gas air system, high pressure boost leak
information recirculation actuator Refer to the electrical circuit diagrams
circuit short circuit to and check exhaust gas recirculation
power, high resistance, actuator circuit for short circuit to
open circuit, power, high resistance, open circuit,
disconnected disconnected. Repair harness as
Exhaust gas required. Using the Jaguar Land Rover
recirculation actuator approved diagnostic system, clear all
failure stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new exhaust gas
recirculation actuator as required

P0403- Exhaust Gas Recirculation The engine control Using the Jaguar Land Rover approved
13 A Control Circuit - Circuit module has diagnostic system, check datalogger
open determined an open signals, EGR Bank 1 - Commanded
circuit via lack of bias (0x03FB)
voltage, low current Refer to the electrical circuit diagrams
flow, no change in the and check the bank 1 exhaust gas
state of an input in recirculation control circuit for open
response to an output circuit. This circuit consists of two wires
Exhaust gas connected between the engine control
recirculation actuator module and the exhaust gas
circuit high resistance, recirculation valve motor. Check both
open circuit, wires for open circuit. Repair harness as
disconnected required. Using the Jaguar Land Rover
Exhaust gas approved diagnostic system, clear all
recirculation actuator stored DTCs using the ‘Diagnosis
failure Menu’ tab and retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new exhaust gas
recirculation control actuator as required

P0403- Exhaust Gas Recirculation The engine control Using the Jaguar Land Rover approved
16 A Control Circuit - Circuit module measured a diagnostic system, check datalogger
voltage below threshold voltage below a signals, EGR Bank 1 - Commanded
specified range but not (0x03FB)
necessarily a short Refer to the electrical circuit diagrams
circuit to ground and check exhaust gas recirculation
Exhaust gas actuator circuit for short circuit to
recirculation actuator ground, high resistance, open circuit,
circuit short circuit to disconnected. Repair harness as
ground, high required. Using the Jaguar Land Rover
resistance, open approved diagnostic system, clear all
circuit, disconnected stored DTCs using the ‘Diagnosis
Exhaust gas Menu’ tab and retest
recirculation actuator Using the Jaguar Land Rover approved
failure diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new exhaust gas
recirculation actuator as required

P0403- Exhaust Gas Recirculation Exhaust gas Using the Jaguar Land Rover approved
19 A Control Circuit - Circuit recirculation actuator diagnostic system, check datalogger
current above threshold circuit short circuit to signals, EGR Bank 1 - Commanded
power (0x03FB). Refer to the electrical circuit
Exhaust gas diagrams and check exhaust gas
recirculation actuator recirculation actuator circuit for short
failure circuit to power. Repair harness as
required. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new exhaust gas
recirculation actuator as required

P0403- Exhaust Gas Recirculation Exhaust gas Using the Jaguar Land Rover approved
1D A Control Circuit - Circuit recirculation actuator diagnostic system, check datalogger
current out of range circuit short circuit to signals, EGR Bank 1 - Commanded
ground, short circuit to (0x03FB)
power, high resistance, Refer to the electrical circuit diagrams
open circuit, and check exhaust gas recirculation
disconnected actuator circuit for short circuit to
Exhaust gas ground, short circuit to power, high
recirculation actuator resistance, disconnected. Repair harness
failure as required. Using the Jaguar Land
Rover approved diagnostic system, clear
all stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new exhaust gas
recirculation actuator as required

P0403- Exhaust Gas Recirculation Exhaust gas Using the Jaguar Land Rover approved
4B A Control Circuit - Over recirculation actuator diagnostic system, check datalogger
temperature circuit short circuit to signals, EGR Bank 1 - Commanded
ground, short circuit to (0x03FB)
power, high resistance, Refer to the electrical circuit diagrams
open circuit, and check exhaust gas recirculation
disconnected actuator circuit for short circuit to
Exhaust gas ground, short circuit to power, high
recirculation actuator resistance, disconnected. Repair harness
failure as required. Using the Jaguar Land
Rover approved diagnostic system, clear
all stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new exhaust gas
recirculation actuator as required

P0403- Exhaust Gas Recirculation Exhaust gas Using the Jaguar Land Rover approved
71 "A" Control Circuit /Open recirculation actuator diagnostic system, check datalogger
- Actuator stuck circuit open circuit, signals, EGR Bank 1 - Commanded
disconnected (0x03FB)
Exhaust gas Refer to the electrical circuit diagrams
recirculation actuator and check exhaust gas recirculation
failure actuator circuit for open circuit,
disconnected. Repair harness as
required. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Check and install new exhaust gas
recirculation actuator as required

P0404- Exhaust Gas Recirculation Exhaust gas Using the Jaguar Land Rover approved
19 A Control Circuit recirculation actuator diagnostic system, check datalogger
Range/Performance - circuit short circuit to signals, EGR Bank 1 - Commanded
Circuit current above ground, short circuit to (0x03FB)
threshold power, high resistance Refer to the electrical circuit diagrams
Exhaust gas and check exhaust gas recirculation
recirculation actuator actuator circuit for short circuit to
failure ground, short circuit to power, high
resistance. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new exhaust gas
recirculation actuator as required

P0405- Exhaust Gas Recirculation Exhaust gas Using the Jaguar Land Rover approved
00 Sensor A Circuit Low - No recirculation actuator diagnostic system, check datalogger
sub type information sensor circuit short signals, EGR Valve Position Bank 1
circuit to ground, high (0x052E)
resistance, open Refer to the electrical circuit diagrams
circuit, disconnected and check exhaust gas recirculation
Exhaust gas actuator sensor circuit for short circuit
recirculation actuator to ground, high resistance, open circuit,
failure disconnected. Repair harness as
required. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new exhaust gas
recirculation actuator as required

P0405- Exhaust Gas Recirculation The engine control Refer to the electrical circuit diagrams
11 Sensor A Circuit Low - module has detected a and check the bank 1 exhaust gas
Circuit short to ground ground measurement recirculation sensor signal circuit for
for a period longer short circuit to ground. Check the power
than expected or has and ground circuits which supply the
detected a ground sensor. Repair harness as required.
measurement when Using the Jaguar Land Rover approved
another value was diagnostic system, clear all stored DTCs
expected using the ‘Diagnosis Menu’ tab and
Exhaust gas retest
recirculation actuator Using the Jaguar Land Rover approved
position sensor circuit diagnostic system, perform routine -
short circuit to ground Inline diagnostic unit 2 diagnostic test -
Exhaust gas Exhaust gas recirculation valve. Clear
recirculation actuator the DTCs and retest
failure Check and install new exhaust gas
recirculation sensor as required

P0405- Exhaust Gas Recirculation Exhaust gas Using the Jaguar Land Rover approved
77 Sensor A Circuit Low - recirculation actuator diagnostic system, check datalogger
Commanded position not position sensor circuit signals, EGR Valve Position Bank 1
reachable short circuit to ground (0x052E)
Exhaust gas Refer to the electrical circuit diagrams
recirculation actuator and check the bank 1 exhaust gas
failure recirculation sensor signal circuit for
short circuit to ground. Check the power
and ground circuits which supply the
sensor. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new exhaust gas
recirculation sensor as required

P0406- Exhaust Gas Recirculation Exhaust gas Using the Jaguar Land Rover approved
00 Sensor A Circuit High - No recirculation actuator diagnostic system, check datalogger
sub type information circuit short circuit to signals, EGR Valve Position Bank 1
power (0x052E)
Exhaust gas Refer to the electrical circuit diagrams
recirculation actuator and check exhaust gas recirculation
failure valve bank 1 circuits for short circuit to
power. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new exhaust gas
recirculation sensor as required

P0406- Exhaust Gas Recirculation The engine control Refer to the electrical circuit diagrams
12 Sensor A Circuit High - module has detected a and check the bank 1 exhaust gas
Circuit short to battery vehicle power recirculation sensor signal circuit for
measurement for a short circuit to power. Repair harness as
period longer than required. Using the Jaguar Land Rover
expected or has approved diagnostic system, clear all
detected a vehicle stored DTCs using the ‘Diagnosis
power measurement Menu’ tab and retest
when another value Using the Jaguar Land Rover approved
was expected diagnostic system, perform routine -
Exhaust gas Inline diagnostic unit 2 diagnostic test -
recirculation actuator Exhaust gas recirculation valve. Clear
position sensor circuit the DTCs and retest
short circuit to power Check and install new exhaust gas
Exhaust gas recirculation sensor as required
recirculation actuator
failure

P0406- Exhaust Gas Recirculation Exhaust gas Refer to the electrical circuit diagrams
77 Sensor A Circuit High - recirculation actuator and check the bank 1 exhaust gas
Commanded position not circuit short circuit to recirculation sensor signal circuit for
reachable power short circuit to power. Check the power
Exhaust gas and ground circuits which supply the
recirculation actuator sensor. Repair harness as required.
failure Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new exhaust gas
recirculation sensor as required

P0407- Exhaust Gas Recirculation Harness failure - Refer to the electrical circuit diagrams
00 Sensor B Circuit Low - No Throttle position and check the throttle position sensor
sub type information sensor circuit circuits for short circuit to ground, open
Throttle position circuit. Repair harness as required, clear
sensor failure the DTC and retest system
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new throttle position
sensor as required

P0408- Exhaust Gas Recirculation Harness failure - Refer to the electrical circuit diagrams
00 Sensor B Circuit High - No Throttle position and check the throttle position sensor
sub type information sensor circuit circuits for short circuit to ground, open
Throttle position circuit. Repair harness as required, clear
sensor failure the DTC and retest system
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new throttle position
sensor as required

P0409- Exhaust Gas Recirculation The engine control Refer to the electrical circuit diagrams
13 Sensor A Circuit - Circuit module has and check the bank 1 exhaust gas
open determined an open recirculation sensor signal circuit for
circuit via lack of bias open circuit. Check the power and
voltage, low current ground circuits which supply the sensor.
flow, no change in the Repair harness as required. Using the
state of an input in Jaguar Land Rover approved diagnostic
response to an output system, clear all stored DTCs using the
Harness failure - ‘Diagnosis Menu’ tab and retest
Exhaust gas Using the Jaguar Land Rover approved
recirculation actuator diagnostic system, perform routine -
circuit Inline diagnostic unit 2 diagnostic test -
Exhaust gas Exhaust gas recirculation valve. Clear
recirculation actuator the DTCs and retest
failure Check and install new exhaust gas
recirculation sensor as required

P0409- Exhaust Gas Recirculation The engine control Refer to the electrical circuit diagrams
16 Sensor A Circuit - Circuit module measured a and check exhaust gas recirculation
voltage below threshold voltage below a actuator sensor circuit for short circuit
specified range but not to ground, high resistance, open circuit,
necessarily a short disconnected. Repair harness as
circuit to ground required. Using the Jaguar Land Rover
Exhaust gas approved diagnostic system, clear all
recirculation actuator stored DTCs using the ‘Diagnosis
circuit short circuit to Menu’ tab and retest
ground, high Using the Jaguar Land Rover approved
resistance, open diagnostic system, perform routine -
circuit, disconnected Inline diagnostic unit 2 diagnostic test -
Exhaust gas Exhaust gas recirculation valve. Clear
recirculation actuator the DTCs and retest
failure Check and install new exhaust gas
recirculation actuator as required

P0409- Exhaust Gas Recirculation The engine control Refer to the electrical circuit diagrams
17 Sensor A Circuit - Circuit module measured a and check exhaust gas recirculation
voltage above threshold voltage above a actuator sensor circuit for short circuit
specified range but not to power. Repair harness as required.
necessarily a short Using the Jaguar Land Rover approved
circuit to power diagnostic system, clear all stored DTCs
Exhaust gas using the ‘Diagnosis Menu’ tab and
recirculation actuator retest
circuit short circuit to Using the Jaguar Land Rover approved
power diagnostic system, perform routine -
Exhaust gas Inline diagnostic unit 2 diagnostic test -
recirculation actuator Exhaust gas recirculation valve. Clear
failure the DTCs and retest
Check and install new exhaust gas
recirculation actuator as required

P0409- Exhaust Gas Recirculation Exhaust gas Refer to the electrical circuit diagrams
92 Sensor A Circuit - recirculation actuator and check exhaust gas recirculation
Performance or incorrect circuit short circuit to actuator sensor circuit for short circuit
operation ground, high to ground, high resistance, open circuit,
resistance, open disconnected. Repair harness as
circuit, disconnected required. Using the Jaguar Land Rover
Exhaust gas approved diagnostic system, clear all
recirculation actuator stored DTCs using the ‘Diagnosis
failure Menu’ tab and retest
Check and install new exhaust gas
recirculation actuator as required

P0426- Catalyst Temperature Exhaust gas Using the Jaguar Land Rover approved
00 Sensor Circuit temperature sensor diagnostic system, check datalogger
Range/Performance (Bank post turbocharger signals, Exhaust Gas Temperature Bank
1, Sensor Circuit 1) - No circuit to ground, high 1 Sensor 1 Voltage (0x03BF), Exhaust
sub type information resistance, open Gas Temperature Bank 2 Sensor 1
circuit, disconnected (0x03F7)
Refer to the electrical circuit diagrams
and check exhaust gas temperature
sensor post turbocharger circuit for short
circuit to ground, high resistance, open
circuit, disconnected
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new exhaust gas
temperature sensor post turbocharger -
bank 2, sensor 1 as required

P0427- Catalyst Temperature Exhaust gas Using the Jaguar Land Rover approved
00 Sensor Circuit Low (Bank temperature sensor diagnostic system, check datalogger
1, Sensor Circuit 1) - No post turbocharger signals, Exhaust Gas Temperature Bank
sub type information circuit to ground, high 1 Sensor 1 Voltage (0x03BF), Exhaust
resistance, open Gas Temperature Bank 2 Sensor 1
circuit, disconnected (0x03F7)
Refer to the electrical circuit diagrams
and check exhaust gas temperature
sensor post turbocharger circuit for short
circuit to ground, high resistance, open
circuit, disconnected
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new exhaust gas
temperature sensor post turbocharger -
bank 2, sensor 1 as required

P0428- Catalyst Temperature Exhaust gas Using the Jaguar Land Rover approved
00 Sensor Circuit High (Bank temperature sensor diagnostic system, check datalogger
1, Sensor Circuit 1) - No post turbocharger signals, Exhaust Gas Temperature Bank
sub type information circuit to power 1 Sensor 1 Voltage (0x03BF), Exhaust
Gas Temperature Bank 2 Sensor 1
(0x03F7)
Refer to the electrical circuit diagrams
and check exhaust gas temperature
sensor post turbocharger circuit for short
circuit to power
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new exhaust gas
temperature sensor post turbocharger -
bank 2, sensor 1 as required

P042B- Catalyst Temperature Exhaust gas Refer to the electrical circuit diagrams
00 Sensor Circuit temperature sensor and check exhaust gas temperature
Range/Performance post catalytic sensor post catalytic converter circuit
(Bank1, Sensor Circuit 2) - converter short circuit for short circuit to ground, open circuit,
No sub type information to ground, open high resistance
circuit, high resistance Check and install new exhaust gas
Exhaust gas temperature sensor post catalytic
temperature sensor converter as required
post catalytic
converter failure

P042C- Catalyst Temperature Exhaust gas Refer to the electrical circuit diagrams
00 Sensor Circuit Low (Bank temperature sensor and check exhaust gas temperature
1, Sensor Circuit 2) - No post catalytic sensor post catalytic converter circuit
sub type information converter short circuit for short circuit to ground, open circuit,
to ground, open high resistance
circuit, high resistance Check and install new exhaust gas
Exhaust gas temperature sensor post catalytic
temperature sensor converter as required
post catalytic
converter failure

P042D- Catalyst Temperature Exhaust gas Refer to the electrical circuit diagrams
00 Sensor Circuit High (Bank temperature sensor and check exhaust gas temperature
1, Sensor Circuit 2) - No post catalytic sensor post catalytic converter circuit
sub type information converter short circuit for short circuit to power, open circuit,
to power, open circuit, high resistance
high resistance Inspect connectors for signs of water
Connector is ingress and pins for damage and/or
disconnected, corrosion
connector pin is Using the Jaguar Land Rover approved
backed out, connector diagnostic system, clear all stored DTCs
pin corrosion using the ‘Diagnosis Menu’ tab and
Exhaust gas retest
temperature sensor Check and install new exhaust gas
post catalytic temperature sensor post catalytic
converter failure converter as required

P042E- Exhaust Gas Recirculation Exhaust gas Check for other related DTCs and refer
77 A Control Stuck Open - recirculation actuator to the relevant DTC index
Commanded position not circuit short circuit to Using the Jaguar Land Rover approved
reachable ground, short circuit to diagnostic system, operate the exhaust
power, high resistance, recirculation valve through the full
open circuit, operating range whilst monitoring the
disconnected position sensor signal value. If the
Exhaust gas position signal does not change
recirculation actuator smoothly in proportion to the commands
failure check the operation of the valve
Refer to the electrical circuit diagrams
and check exhaust gas recirculation
actuator circuit for short circuit to
ground, short circuit to power, high
resistance, open circuit, disconnected.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new exhaust gas
recirculation actuator as required

P042F- Exhaust Gas Recirculation Exhaust gas Check for other related DTCs and refer
77 A Control Stuck Closed - recirculation actuator to the relevant DTC index
Commanded position not circuit short circuit to Using the Jaguar Land Rover approved
reachable ground, short circuit to diagnostic system, operate the exhaust
power, high resistance, recirculation valve through the full
open circuit, operating range whilst monitoring the
disconnected position sensor signal value. If the
Exhaust gas position signal does not change
recirculation actuator smoothly in proportion to the commands
failure check the operation of the valve
Refer to the electrical circuit diagrams
and check exhaust gas recirculation
actuator circuit for short circuit to
ground, short circuit to power, high
resistance, open circuit, disconnected.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new exhaust gas
recirculation actuator as required

P0435- Catalyst Temperature Exhaust gas Using the Jaguar Land Rover approved
00 Sensor Circuit (Bank 2, temperature sensor diagnostic system, check datalogger
Sensor Circuit 1) - No sub post turbocharger bank signals, Exhaust Gas Temperature Bank
type information 2, sensor 1 circuit 1 Sensor 1 Voltage (0x03BF), Exhaust
short circuit to ground, Gas Temperature Bank 2 Sensor 1
short circuit to power, (0x03F7)
high resistance, open Refer to the electrical circuit diagrams
circuit, disconnected and check exhaust gas temperature
sensor post turbocharger bank 2, sensor
1 circuit for short circuit to ground,
short circuit to power, high resistance,
open circuit, disconnected. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new exhaust gas
temperature sensor post turbocharger -
bank 2, sensor 1 as required
P0436- Catalyst Temperature Exhaust gas Refer to the electrical circuit diagrams
00 Sensor Circuit temperature sensor and check exhaust gas temperature
Range/Performance (Bank post turbocharger sensor post turbocharger circuit for short
2, Sensor Circuit 1) - No overheating circuit to ground, open circuit, high
sub type information Exhaust gas resistance
temperature sensor Clear the DTC and retest
post turbocharger Check and install new exhaust gas
short circuit short temperature sensor post turbocharger as
circuit to ground, open required
circuit, high resistance
Exhaust gas
temperature sensor
post turbocharger
failure

P0437- Catalyst Temperature Exhaust gas Using the Jaguar Land Rover approved
00 Sensor Circuit Low (Bank temperature sensor diagnostic system, check datalogger
2, Sensor Circuit 1) - No post turbocharger bank signals, Exhaust Gas Temperature Bank
sub type information 2, sensor 1 circuit 1 Sensor 1 Voltage (0x03BF), Exhaust
short circuit to ground, Gas Temperature Bank 2 Sensor 1
high resistance, open (0x03F7)
circuit, disconnected Refer to the electrical circuit diagrams
Exhaust gas and check exhaust gas temperature
temperature sensor sensor post turbocharger bank 2, sensor
post turbocharger bank 1 circuit for short circuit to ground, high
2, sensor 1 failure resistance, open circuit, disconnected.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new exhaust gas
temperature sensor post turbocharger -
bank 2, sensor 1 as required

P0438- Catalyst Temperature Exhaust gas Using the Jaguar Land Rover approved
00 Sensor Circuit High (Bank temperature sensor diagnostic system, check datalogger
2, Sensor Circuit 1) - No post turbocharger bank signals, Exhaust Gas Temperature Bank
sub type information 2, sensor 1 circuit 1 Sensor 1 Voltage (0x03BF), Exhaust
short circuit to power Gas Temperature Bank 2 Sensor 1
Exhaust gas (0x03F7).
temperature sensor Refer to the electrical circuit diagrams
post turbocharger bank and check exhaust gas temperature
2, sensor 1 failure sensor post turbocharger bank 2, sensor
1 circuit for short circuit to power.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new exhaust gas
temperature sensor post turbocharger -
bank 2, sensor 1 as required

P043A- Catalyst Temperature Exhaust gas Using the Jaguar Land Rover approved
00 Sensor Circuit (Bank 2, temperature sensor diagnostic system, check datalogger
Sensor Circuit 2) - No sub post turbocharger bank signals, Exhaust Gas Temperature Bank
type information 2, sensor 2 circuit 2 Sensor 2 (0x03F8), Exhaust Gas
short circuit to ground, Temperature Sensor Bank 2 Sensor 2
short circuit to power, Voltage (0x03E9)
high resistance, open Refer to the electrical circuit diagrams
circuit, disconnected and check exhaust gas temperature
Exhaust gas sensor post turbocharger bank 2, sensor
temperature sensor 2 circuit for short circuit to ground,
post turbocharger bank short circuit to power, high resistance,
2, sensor 2 failure open circuit, disconnected. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new exhaust gas
temperature sensor post turbocharger -
bank 2, sensor 2 as required

P043B- Catalyst Temperature Exhaust gas Using the Jaguar Land Rover approved
00 Sensor Circuit temperature sensor diagnostic system, check datalogger
Range/Performance (Bank post turbocharger bank signals, Exhaust Gas Temperature Bank
2, Sensor Circuit 2) - No 2, sensor 2 circuit 2 Sensor 2 (0x03F8), Exhaust Gas
sub type information short circuit to ground, Temperature Sensor Bank 2 Sensor 2
short circuit to power, Voltage (0x03E9)
high resistance, open Refer to the electrical circuit diagrams
circuit, disconnected and check exhaust gas temperature
Exhaust gas sensor post turbocharger bank 2, sensor
temperature sensor 2 circuit for short circuit to ground,
post turbocharger bank short circuit to power, high resistance,
2, sensor 2 failure open circuit, disconnected. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new exhaust gas
temperature sensor post turbocharger -
bank 2, sensor 2 as required

P043C- Catalyst Temperature Exhaust gas Using the Jaguar Land Rover approved
00 Sensor Circuit Low (Bank temperature sensor diagnostic system, check datalogger
2, Sensor Circuit 2) - No post turbocharger bank signals, Exhaust Gas Temperature Bank
sub type information 2, sensor 2 circuit 2 Sensor 2 (0x03F8), Exhaust Gas
short circuit to ground, Temperature Sensor Bank 2 Sensor 2
high resistance, open Voltage (0x03E9)
circuit, disconnected Refer to the electrical circuit diagrams
Exhaust gas and check exhaust gas temperature
temperature sensor sensor post turbocharger bank 2, sensor
post turbocharger bank 2 circuit for short circuit to ground, high
2, sensor 2 failure resistance, open circuit, disconnected.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new exhaust gas
temperature sensor post turbocharger -
bank 2, sensor 2 as required

P043D- Catalyst Temperature Exhaust gas Using the Jaguar Land Rover approved
00 Sensor Circuit High (Bank temperature sensor diagnostic system, check datalogger
2, Sensor Circuit 2) - No post turbocharger bank signals, Exhaust Gas Temperature Bank
sub type information 2, sensor 2 circuit 2 Sensor 2 (0x03F8), Exhaust Gas
short circuit to power Temperature Sensor Bank 2 Sensor 2
Exhaust gas Voltage (0x03E9)
temperature sensor Refer to the electrical circuit diagrams
post turbocharger bank and check exhaust gas temperature
2, sensor 2 failure sensor post turbocharger bank 2, sensor
2 circuit for short circuit to power.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new exhaust gas
temperature sensor post turbocharger -
bank 2, sensor 2 as required

P044A- Exhaust Gas Recirculation The engine control Using the Jaguar Land Rover approved
13 Sensor C Circuit - Circuit module has diagnostic system, check datalogger
open determined an open signals, EGR Valve Position Bank 2
circuit via lack of bias (0x052F)
voltage, low current Refer to the electrical circuit diagrams
flow, no change in the and check the bank 2 exhaust gas
state of an input in recirculation sensor signal circuit for
response to an output open circuit. Repair harness as required.
Exhaust gas Using the Jaguar Land Rover approved
recirculation valve diagnostic system, clear all stored DTCs
bank 2 circuit high using the ‘Diagnosis Menu’ tab and
resistance, open retest
circuit, disconnected Using the Jaguar Land Rover approved
Exhaust gas diagnostic system, perform routine -
recirculation valve Inline diagnostic unit 2 diagnostic test -
bank 2 failure Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new exhaust gas
recirculation valve bank 2 as required

P044A- Exhaust Gas Recirculation The engine control Using the Jaguar Land Rover approved
16 Sensor C Circuit - Circuit module measured a diagnostic system, check datalogger
voltage below threshold voltage below a signals, EGR Valve Position Bank 2
specified range but not (0x052F)
necessarily a short Refer to the electrical circuit diagrams
circuit to ground and check exhaust gas recirculation
Exhaust gas valve bank 2 circuit for short circuit to
recirculation valve ground, high resistance, disconnected.
bank 2 circuit short Repair harness as required. Using the
circuit to ground, high Jaguar Land Rover approved diagnostic
resistance, system, clear all stored DTCs using the
disconnected ‘Diagnosis Menu’ tab and retest
Exhaust gas Using the Jaguar Land Rover approved
recirculation valve diagnostic system, perform routine -
bank 2 failure Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new exhaust gas
recirculation valve bank 2 as required

P044A- Exhaust Gas Recirculation The engine control Using the Jaguar Land Rover approved
17 Sensor C Circuit - Circuit module measured a diagnostic system, check datalogger
voltage above threshold voltage above a signals, EGR Valve Position Bank 2
specified range but not (0x052F).
necessarily a short Refer to the electrical circuit diagrams
circuit to power and check exhaust gas recirculation
Exhaust gas valve bank 2 circuit for short circuit to
recirculation valve power. Repair harness as required.
bank 2 circuit short Using the Jaguar Land Rover approved
circuit to power diagnostic system, clear all stored DTCs
Exhaust gas using the ‘Diagnosis Menu’ tab and
recirculation valve retest
bank 2 failure Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new exhaust gas
recirculation valve bank 2 as required

P044A- Exhaust Gas Recirculation Exhaust gas Using the Jaguar Land Rover approved
92 Sensor C Circuit - recirculation valve diagnostic system, check datalogger
Performance or incorrect bank 2 circuit short signals, EGR Valve Position Bank 2
operation circuit to ground, short (0x052F)
circuit to power, open Refer to the electrical circuit diagrams
circuit, high and check exhaust gas recirculation
resistance, valve bank 2 circuit for short circuit to
disconnected ground, short circuit to power, open
Exhaust gas circuit, high resistance, disconnected.
recirculation valve Repair harness as required. Using the
bank 2 failure Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new exhaust gas
recirculation valve bank 2 as required

P044C- Exhaust Gas Recirculation Exhaust gas Using the Jaguar Land Rover approved
00 Sensor C Circuit Low - No recirculation valve diagnostic system, check datalogger
sub type information bank 2 circuit short signals, EGR Valve Position Bank 2
circuit to ground, high (0x052F)
resistance, open Refer to the electrical circuit diagrams
circuit, disconnected and check exhaust gas recirculation
Exhaust gas valve bank 2 circuit for short circuit to
recirculation valve ground, high resistance, open circuit,
bank 2 failure disconnected. Repair harness as
required. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new exhaust gas
recirculation valve bank 2 as required

P044D- Exhaust Gas Recirculation Exhaust gas Using the Jaguar Land Rover approved
00 Sensor C Circuit High - No recirculation valve diagnostic system, check datalogger
sub type information bank 2 circuit short signals, EGR Valve Position Bank 2
circuit to power (0x052F)
Exhaust gas Refer to the electrical circuit diagrams
recirculation valve and check exhaust gas recirculation
bank 2 failure valve bank 2 circuit for short circuit to
power. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new exhaust gas
recirculation valve bank 2 as required

P045A- Exhaust Gas Recirculation The engine control Using the Jaguar Land Rover approved
13 B Control Circuit - Circuit module has diagnostic system, check datalogger
open determined an open signals, Commanded EGR Bank 2
circuit via lack of bias (0x0525)
voltage, low current Refer to the electrical circuit diagrams
flow, no change in the and check the bank 2 exhaust gas
state of an input in recirculation control circuit for open
response to an output circuit, disconnected. Check both wires.
Exhaust gas Repair harness as required. Using the
recirculation valve Jaguar Land Rover approved diagnostic
bank 2 circuit open system, clear all stored DTCs using the
circuit, disconnected ‘Diagnosis Menu’ tab and retest
Exhaust gas Using the Jaguar Land Rover approved
recirculation valve diagnostic system, perform routine -
bank 2 failure Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new exhaust gas
recirculation control actuator as required

P045A- Exhaust Gas Recirculation The engine control Using the Jaguar Land Rover approved
16 B Control Circuit - Circuit module measured a diagnostic system, check datalogger
voltage below threshold voltage below a signals, Commanded EGR Bank 2
specified range but not (0x0525)
necessarily a short Refer to the electrical circuit diagrams
circuit to ground and check exhaust gas recirculation
Exhaust gas valve bank 2 circuit for short circuit to
recirculation valve ground, high resistance, open circuit,
bank 2 circuit short disconnected. Check both circuits.
circuit to ground, high Repair harness as required. Using the
resistance, open Jaguar Land Rover approved diagnostic
circuit, disconnected system, clear all stored DTCs using the
Exhaust gas ‘Diagnosis Menu’ tab and retest
recirculation valve Using the Jaguar Land Rover approved
bank 2 failure diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new exhaust gas
recirculation valve bank 2 as required

P045A- Exhaust Gas Recirculation The engine control Using the Jaguar Land Rover approved
19 B Control Circuit - Circuit module has measured diagnostic system, check datalogger
current above threshold current flow above a signals, Commanded EGR Bank 2
specified range (0x0525)
Exhaust gas Refer to the electrical circuit diagrams
recirculation valve and check exhaust gas recirculation
bank 2 circuit short valve bank 2 circuit for short circuit to
circuit to ground, short ground, short circuit to power, high
circuit to power, high resistance, open circuit, disconnected.
resistance, open Check both circuits. Repair harness as
circuit, disconnected required. Using the Jaguar Land Rover
Exhaust gas approved diagnostic system, clear all
recirculation valve stored DTCs using the ‘Diagnosis
bank 2 failure Menu’ tab and retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new exhaust gas
recirculation valve bank 2 as required

P045A- Exhaust Gas Recirculation The engine control Using the Jaguar Land Rover approved
1D B Control Circuit - Circuit module has detected a diagnostic system, check datalogger
current out of range current outside of the signals, Commanded EGR Bank 2
expected range, but (0x0525)
not identified as too Refer to the electrical circuit diagrams
high or too low and check exhaust gas recirculation
Exhaust gas valve bank 2 circuit for short circuit to
recirculation valve ground, short circuit to power, high
bank 2 circuit short resistance, open circuit, disconnected.
circuit to ground, short Check both circuits. Repair harness as
circuit to power, high required. Using the Jaguar Land Rover
resistance, open approved diagnostic system, clear all
circuit, disconnected stored DTCs using the ‘Diagnosis
Exhaust gas Menu’ tab and retest
recirculation valve Using the Jaguar Land Rover approved
bank 2 failure diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new exhaust gas
recirculation valve bank 2 as required

P045A- Exhaust Gas Recirculation The engine control Using the Jaguar Land Rover approved
4B B Control Circuit - Over module detected an diagnostic system, check datalogger
temperature internal temperature signals, Commanded EGR Bank 2
above the expected (0x0525)
range Refer to the electrical circuit diagrams
Exhaust gas and check exhaust gas recirculation
recirculation valve valve bank 2 circuit for short circuit to
bank 2 circuit short ground, short circuit to power, high
circuit to ground, short resistance. Check both circuits. Repair
circuit to power, high harness as required. Using the Jaguar
resistance Land Rover approved diagnostic
Exhaust gas system, clear all stored DTCs using the
recirculation valve ‘Diagnosis Menu’ tab and retest
bank 2 failure Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new exhaust gas
recirculation valve bank 2 as required

P045A- Exhaust Gas Recirculation Exhaust gas Using the Jaguar Land Rover approved
71 B Control Circuit - recirculation valve diagnostic system, check datalogger
Actuator stuck bank 2 circuit short signals, Commanded EGR Bank 2
circuit to ground, short (0x0525)
circuit to power, open Refer to the electrical circuit diagrams
circuit, high resistance and check exhaust gas recirculation
Exhaust gas valve bank 2 circuit for short circuit to
recirculation valve ground, short circuit to power, open
bank 2 failure circuit, high resistance. Check both
circuits. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new exhaust gas
recirculation valve bank 2 as required

P045B- Exhaust Gas Recirculation The engine control Using the Jaguar Land Rover approved
19 B Control Circuit module has measured diagnostic system, check datalogger
Range/Performance - current flow above a signals, Commanded EGR Bank 2
Circuit current above specified range (0x0525)
threshold Exhaust gas Refer to the electrical circuit diagrams
recirculation valve and check exhaust gas recirculation
bank 2 circuit short valve bank 2 circuit for short circuit to
circuit to ground, short ground, short circuit to power, high
circuit to power, high resistance, open circuit, disconnected.
resistance, open Repair harness as required. Using the
circuit, disconnected Jaguar Land Rover approved diagnostic
Exhaust gas system, clear all stored DTCs using the
recirculation valve ‘Diagnosis Menu’ tab and retest
bank 2 failure Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new exhaust gas
recirculation valve bank 2 as required

P045C- Exhaust Gas Recirculation Exhaust gas Using the Jaguar Land Rover approved
00 B Control Circuit Low - recirculation valve diagnostic system, check datalogger
No sub type information bank 2 circuit short signals, Commanded EGR Bank 2
circuit to ground, high (0x0525)
resistance, open Refer to the electrical circuit diagrams
circuit, disconnected and check exhaust gas recirculation
Exhaust gas valve bank 2 circuit for short circuit to
recirculation valve ground, high resistance, open circuit,
bank 2 failure disconnected. Check both circuits.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new exhaust gas
recirculation valve bank 2 as required

P045C- Exhaust Gas Recirculation The engine control Using the Jaguar Land Rover approved
11 B Control Circuit Low - module has detected a diagnostic system, check datalogger
Circuit short to ground ground measurement signals, Commanded EGR Bank 2
for a period longer (0x0525). Refer to the electrical circuit
than expected or has diagrams and check exhaust gas
detected a ground recirculation valve bank 2 circuit for
measurement when short circuit to ground. Repair harness
another value was as required. Using the Jaguar Land
expected Rover approved diagnostic system, clear
Exhaust gas all stored DTCs using the ‘Diagnosis
recirculation valve Menu’ tab and retest
bank 2 circuit short Using the Jaguar Land Rover approved
circuit to ground diagnostic system, perform routine -
Exhaust gas Inline diagnostic unit 2 diagnostic test -
recirculation valve Exhaust gas recirculation valve. Clear
bank 2 failure the DTCs and retest
Check and install new exhaust gas
recirculation valve bank 2 as required

P045C- Exhaust Gas Recirculation Exhaust gas Using the Jaguar Land Rover approved
77 B Control Circuit Low - recirculation valve diagnostic system, check datalogger
Commanded position not bank 2 circuit short signals, Commanded EGR Bank 2
reachable circuit to ground (0x0525). Refer to the electrical circuit
Exhaust gas diagrams and check exhaust gas
recirculation valve recirculation valve bank 2 circuit for
bank 2 failure short circuit to ground. Repair harness
as required. Using the Jaguar Land
Rover approved diagnostic system, clear
all stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Check and install new exhaust gas
recirculation valve bank 2 as required

P045D- Exhaust Gas Recirculation Exhaust gas Using the Jaguar Land Rover approved
00 B Control Circuit High - recirculation valve diagnostic system, check datalogger
No sub type information bank 2 circuit short signals, Commanded EGR Bank 2
circuit to power (0x0525). Refer to the electrical circuit
Exhaust gas diagrams and check exhaust gas
recirculation valve recirculation valve bank 2 circuit for
bank 2 failure short circuit to power. Repair harness as
required. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new exhaust gas
recirculation valve bank 2 as required

P045D- Exhaust Gas Recirculation The engine control Using the Jaguar Land Rover approved
12 B Control Circuit High - module has detected a diagnostic system, check datalogger
Circuit short to battery vehicle power signals, Commanded EGR Bank 2
measurement for a (0x0525). Refer to the electrical circuit
period longer than diagrams and check exhaust gas
expected or has recirculation valve bank 2 circuit for
detected a vehicle short circuit to power. Repair harness as
power measurement required. Using the Jaguar Land Rover
when another value approved diagnostic system, clear all
was expected stored DTCs using the ‘Diagnosis
Exhaust gas Menu’ tab and retest
recirculation valve Using the Jaguar Land Rover approved
bank 2 circuit short diagnostic system, perform routine -
circuit to power Inline diagnostic unit 2 diagnostic test -
Exhaust gas Exhaust gas recirculation valve. Clear
recirculation valve the DTCs and retest
bank 2 failure Check and install new exhaust gas
recirculation valve bank 2 as required

P045D- Exhaust Gas Recirculation Exhaust gas Using the Jaguar Land Rover approved
77 B Control Circuit High - recirculation valve diagnostic system, check datalogger
Commanded position not bank 2 circuit short signals, Commanded EGR Bank 2
reachable circuit to power (0x0525). Refer to the electrical circuit
Exhaust gas diagrams and check exhaust gas
recirculation valve recirculation valve bank 2 circuit for
bank 2 failure short circuit to power. Repair harness as
required. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Check and install new exhaust gas
recirculation valve bank 2 as required

P045E- Exhaust Gas Recirculation Exhaust gas Check for other related DTCs and refer
77 B Control Stuck Open - recirculation valve B to the relevant DTC index
Commanded position not circuit short circuit to Using the Jaguar Land Rover approved
reachable ground, short circuit to diagnostic system, operate the Exhaust
power, high resistance, Recirculation Valve through the full
open circuit, operating range whilst monitoring the
disconnected position sensor signal value. If the
Exhaust gas position signal does not change
recirculation valve B smoothly in proportion to the commands
failure check the operation of the valve
Refer to the electrical circuit diagrams
and check exhaust gas recirculation
valve B circuit for short circuit to
ground, short circuit to power, high
resistance, open circuit, disconnected.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new exhaust gas
recirculation valve B as required

P045F- Exhaust Gas Recirculation Exhaust gas Check for other related DTCs and refer
77 B Control Stuck Closed - recirculation valve B to the relevant DTC index
Commanded position not circuit short circuit to Using the Jaguar Land Rover approved
reachable ground, short circuit to diagnostic system, operate the Exhaust
power, high resistance, Recirculation Valve through the full
open circuit, operating range whilst monitoring the
disconnected position sensor signal value. If the
Exhaust gas position signal does not change
recirculation valve B smoothly in proportion to the commands
failure check the operation of the valve
Refer to the electrical circuit diagrams
and check exhaust gas recirculation
valve B circuit for short circuit to
ground, short circuit to power, high
resistance, open circuit, disconnected.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new exhaust gas
recirculation valve B as required

P046E- Exhaust Gas Recirculation Throttle position Refer to the electrical circuit diagrams
00 Sensor "B" Circuit sensor short circuit to and check throttle position sensor for
Range/Performance - No ground, short circuit to short circuit to ground, short circuit to
sub type information power, open circuit, power, open circuit, high resistance.
high resistance Repair harness as required. Using the
Throttle position Jaguar Land Rover approved diagnostic
sensor failure system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new throttle position
sensor as required

P0480- Fan 1 Control Circuit - The engine control Using the Jaguar Land Rover approved
11 Circuit short to ground module has detected a diagnostic system, check datalogger
ground measurement signals, Electric Fan PWM Control -
for a period longer Commanded (0x03F9). Refer to the
than expected or has electrical circuit diagrams and check the
detected a ground cooling fan 1 control circuit for short
measurement when circuit to ground. Check the power and
another value was ground supplies to the cooling fan 1
expected control module. Repair harness as
Fan 1 control circuit - required. Using the Jaguar Land Rover
Short circuit to ground approved diagnostic system, clear all
Cooling fan 1 stored DTCs using the ‘Diagnosis
component failure Menu’ tab and retest
If fault persists, refer to the relevant
section of the workshop manual and
refer to the cooling fan pinpoint test
procedures For additional information,
refer to: Engine Cooling (303-03B
Engine Cooling - TDV6 3.0L Diesel,
Diagnosis and Testing).
Check and install new cooling fan 1
control module as required

P0480- Fan 1 Control Circuit - The engine control Using the Jaguar Land Rover approved
12 Circuit short to battery module has detected a diagnostic system, check datalogger
vehicle power signals, Electric Fan PWM Control -
measurement for a Commanded (0x03F9). Refer to the
period longer than electrical circuit diagrams and check the
expected or has cooling fan 1 control circuit for short
detected a vehicle circuit to power. Check the power and
power measurement ground supplies to the cooling fan 1
when another value control module. Repair harness as
was expected required. Using the Jaguar Land Rover
Fan 1 control circuit - approved diagnostic system, clear all
Short circuit to power stored DTCs using the ‘Diagnosis
Cooling fan 1 Menu’ tab and retest
component failure If fault persists, refer to the relevant
section of the workshop manual and
refer to the cooling fan pinpoint test
procedures For additional information,
refer to: Engine Cooling (303-03B
Engine Cooling - TDV6 3.0L Diesel,
Diagnosis and Testing).
Check and install new cooling fan 1
control module as required

P0480- Fan 1 Control Circuit - The engine control Using the Jaguar Land Rover approved
13 Circuit open module has diagnostic system, check datalogger
determined an open signals, Electric Fan PWM Control -
circuit via lack of bias Commanded (0x03F9). Refer to the
voltage, low current electrical circuit diagrams and check the
flow, no change in the cooling fan 1 control circuit for open
state of an input in circuit. Check the power and ground
response to an output supplies to the cooling fan 1 control
Fan 1 control circuit - module. Repair harness as required.
Open circuit Using the Jaguar Land Rover approved
Cooling fan 1 diagnostic system, clear all stored DTCs
component failure using the ‘Diagnosis Menu’ tab and
retest
If fault persists, refer to the relevant
section of the workshop manual and
refer to the cooling fan pinpoint test
procedures For additional information,
refer to: Engine Cooling (303-03B
Engine Cooling - TDV6 3.0L Diesel,
Diagnosis and Testing).
Check and install new cooling fan 1
control module as required

P0480- Fan 1 Control Circuit - The engine control Refer to the electrical circuit diagrams
16 Circuit voltage below module has and check the fan 1 supply circuit for
threshold determined that the fan short circuit to ground, open circuit,
1 supply voltage is high resistance. Check the power and
below the calibrated ground supplies to the cooling fan 1
threshold control module. Repair harness as
Fan 1 control circuit - required. Using the Jaguar Land Rover
Open circuit, short approved diagnostic system, clear all
circuit to ground, high stored DTCs using the ‘Diagnosis
resistance Menu’ tab and retest
Cooling fan 1 control If fault persists, refer to the relevant
module failure section of the workshop manual and
refer to the cooling fan pinpoint test
procedures For additional information,
refer to: Engine Cooling (303-03B
Engine Cooling - TDV6 3.0L Diesel,
Diagnosis and Testing).
Check and install new cooling fan 1
control module as required

P0480- Fan 1 Control Circuit - The engine control Refer to the electrical circuit diagrams
17 Circuit voltage above module has and check the fan 1 supply circuit for
threshold determined that the fan short circuit to power. Check the power
1 supply voltage is and ground supplies to the cooling fan 1
above the calibrated control module. Repair harness as
threshold required. Using the Jaguar Land Rover
Fan 1 control circuit - approved diagnostic system, clear all
Short circuit to power stored DTCs using the ‘Diagnosis
Cooling fan 1 control Menu’ tab and retest
module failure If fault persists, refer to the relevant
section of the workshop manual and
refer to the cooling fan pinpoint test
procedures For additional information,
refer to: Engine Cooling (303-03B
Engine Cooling - TDV6 3.0L Diesel,
Diagnosis and Testing).
Check and install new cooling fan 1
control module as required

P0480- Fan 1 Control Circuit - Engine cooling fan Confirm if customer has been deep
71 Actuator stuck partially stalled water wading
Engine cooling fan Check for damage to or blockages in fan
stalling caused by and fouling of fan cowling. Rectify as
deep water wading required
Engine cooling fan Using the Jaguar Land Rover approved
stalling caused by diagnostic system, check datalogger
obstruction in fan signal - Electric Fan PWM Control -
cowling Commanded - (0x03F9)
Using the Jaguar Land Rover approved
diagnostic system, operate cooling fan 1
through the full operating range and
check that the DTC does not reset
If fault persists, refer to the relevant
section of the workshop manual and
refer to the cooling fan pinpoint test
procedures For additional information,
refer to: Engine Cooling (303-03B
Engine Cooling - TDV6 3.0L Diesel,
Diagnosis and Testing).

P0480- Fan 1 Control Circuit - Engine cooling fan Confirm if customer has been deep
97 Component or system stalled water wading
operation obstructed or Engine cooling fan Check for damage to or blockages in fan
blocked stalling caused by and fouling of fan cowling. Rectify as
deep water wading required
Engine cooling fan Using the Jaguar Land Rover approved
stalling caused by diagnostic system, check datalogger
obstruction in fan signal - Electric Fan PWM Control -
cowling Commanded - (0x03F9)
Using the Jaguar Land Rover approved
diagnostic system, operate cooling fan 1
through the full operating range and
check that the DTC does not reset
If fault persists, refer to the relevant
section of the workshop manual and
refer to the cooling fan pinpoint test
procedures For additional information,
refer to: Engine Cooling (303-03B
Engine Cooling - TDV6 3.0L Diesel,
Diagnosis and Testing).

P0481- Fan 2 Control Circuit - The engine control Using the Jaguar Land Rover approved
11 Circuit short to ground module has detected a diagnostic system, check datalogger
ground measurement signals, Electric Fan PWM Control -
for a period longer Commanded (0x03FA). Refer to the
than expected or has electrical circuit diagrams and check the
detected a ground cooling fan 2 control circuit for short
measurement when circuit to ground. Check the power and
another value was ground supplies to the cooling fan 2
expected control module. Repair harness as
Fan 2 control circuit - required. Using the Jaguar Land Rover
Short circuit to ground approved diagnostic system, clear all
Cooling fan 2 stored DTCs using the ‘Diagnosis
component failure Menu’ tab and retest
If fault persists, refer to the relevant
section of the workshop manual and
refer to the cooling fan pinpoint test
procedures For additional information,
refer to: Engine Cooling (303-03B
Engine Cooling - TDV6 3.0L Diesel,
Diagnosis and Testing).
Check and install new cooling fan 2
control module as required

P0481- Fan 2 Control Circuit - The engine control Using the Jaguar Land Rover approved
12 Circuit short to battery module has detected a diagnostic system, check datalogger
vehicle power signals, Electric Fan PWM Control -
measurement for a Commanded (0x03FA). Refer to the
period longer than electrical circuit diagrams and check the
expected or has cooling fan 2 control circuit for short
detected a vehicle circuit to power. Check the power and
power measurement ground supplies to the cooling fan 2
when another value control module. Repair harness as
was expected required. Using the Jaguar Land Rover
Fan 2 control circuit - approved diagnostic system, clear all
Short circuit to power stored DTCs using the ‘Diagnosis
Cooling fan 2 Menu’ tab and retest
component failure If fault persists, refer to the relevant
section of the workshop manual and
refer to the cooling fan pinpoint test
procedures For additional information,
refer to: Engine Cooling (303-03B
Engine Cooling - TDV6 3.0L Diesel,
Diagnosis and Testing).
Check and install new cooling fan 2
control module as required

P0481- Fan 2 Control Circuit - The engine control Using the Jaguar Land Rover approved
13 Circuit open module has diagnostic system, check datalogger
determined an open signals, Electric Fan PWM Control -
circuit via lack of bias Commanded (0x03FA). Refer to the
voltage, low current electrical circuit diagrams and check the
flow, no change in the cooling fan 2 control circuit for open
state of an input in circuit. Check the power and ground
response to an output supplies to the cooling fan 2 control
Fan 2 control circuit - module. Repair harness as required.
Open circuit Using the Jaguar Land Rover approved
Cooling fan 2 diagnostic system, clear all stored DTCs
component failure using the ‘Diagnosis Menu’ tab and
retest
If fault persists, refer to the relevant
section of the workshop manual and
refer to the cooling fan pinpoint test
procedures For additional information,
refer to: Engine Cooling (303-03B
Engine Cooling - TDV6 3.0L Diesel,
Diagnosis and Testing).
Check and install new cooling fan 2
control module as required

P0481- Fan 2 Control Circuit - The engine control Refer to the electrical circuit diagrams
16 Circuit voltage below module has and check the fan 2 supply circuit for
threshold determined that the fan short circuit to ground, open circuit,
2 supply voltage is high resistance. Check the power and
below the calibrated ground supplies to the cooling fan 2
threshold control module. Repair harness as
Fan 2 control circuit - required. Using the Jaguar Land Rover
Open circuit, short approved diagnostic system, clear all
circuit to ground, high stored DTCs using the ‘Diagnosis
resistance Menu’ tab and retest
Cooling fan 2 control If fault persists, refer to the relevant
module failure section of the workshop manual and
refer to the cooling fan pinpoint test
procedures For additional information,
refer to: Engine Cooling (303-03B
Engine Cooling - TDV6 3.0L Diesel,
Diagnosis and Testing).
Check and install new cooling fan 2
control module as required

P0481- Fan 2 Control Circuit - The engine control Refer to the electrical circuit diagrams
17 Circuit voltage above module has and check the fan 2 supply circuit for
threshold determined that the fan short circuit to power. Check the power
2 supply voltage is and ground supplies to the cooling fan 2
above the calibrated control module. Repair harness as
threshold required. Using the Jaguar Land Rover
Fan 2 control circuit - approved diagnostic system, clear all
Short circuit to power stored DTCs using the ‘Diagnosis
Cooling fan 2 control Menu’ tab and retest
module failure If fault persists, refer to the relevant
section of the workshop manual and
refer to the cooling fan pinpoint test
procedures For additional information,
refer to: Engine Cooling (303-03B
Engine Cooling - TDV6 3.0L Diesel,
Diagnosis and Testing).
Check and install new cooling fan 2
control module as required

P0481- Fan 2 Control Circuit - Engine cooling fan Confirm if customer has been deep
71 Actuator stuck partially stalled water wading
Engine cooling fan Check for damage to or blockages in fan
stalling caused by and fouling of fan cowling. Rectify as
deep water wading required
Engine cooling fan Using the Jaguar Land Rover approved
stalling caused by diagnostic system, check datalogger
obstruction in fan signal - Viscous Fan PWM Control -
cowling Commanded - (0x03FA)
Using the Jaguar Land Rover approved
diagnostic system, operate cooling fan 2
through the full operating range and
check that the DTC does not reset
If fault persists, refer to the relevant
section of the workshop manual and
refer to the cooling fan pinpoint test
procedures For additional information,
refer to: Engine Cooling (303-03B
Engine Cooling - TDV6 3.0L Diesel,
Diagnosis and Testing).

P0481- Fan 2 Control Circuit - Engine cooling fan Confirm if customer has been deep
97 Component or system stalled water wading
operation obstructed or Engine cooling fan Check for damage to or blockages in fan
blocked stalling caused by and fouling of fan cowling. Rectify as
deep water wading required
Engine cooling fan Using the Jaguar Land Rover approved
stalling caused by diagnostic system, check datalogger
obstruction in fan signal - Viscous Fan PWM Control -
cowling Commanded - (0x03FA)
Using the Jaguar Land Rover approved
diagnostic system, operate cooling fan 2
through the full operating range and
check that the DTC does not reset
If fault persists, refer to the relevant
section of the workshop manual and
refer to the cooling fan pinpoint test
procedures For additional information,
refer to: Engine Cooling (303-03B
Engine Cooling - TDV6 3.0L Diesel,
Diagnosis and Testing).

P0483- Fan Performance - Signal Engine cooling fan Refer to relevant section of workshop
27 rate of change above acceleration manual and check the viscous fan unit
threshold plausibility defect If fault persists, refer to the relevant
This DTC is set if the section of the workshop manual and
calculated engine refer to the cooling fan pinpoint test
cooling fan procedures For additional information,
acceleration value is refer to: Engine Cooling (303-03B
greater than a Engine Cooling - TDV6 3.0L Diesel,
calibrated value Diagnosis and Testing).

P0483- Fan Performance - Signal The engine control Refer to electrical circuit diagrams and
36 frequency too low module detected check the viscous fan circuit for short
excessive duration for circuit to ground, short circuit to power,
one cycle of the output open circuit, high resistance
across a specified If fault persists, refer to the relevant
sample size section of the workshop manual and
Engine cooling fan refer to the cooling fan pinpoint test
speed below procedures For additional information,
maximum threshold refer to: Engine Cooling (303-03B
Viscous fan circuit Engine Cooling - TDV6 3.0L Diesel,
short circuit to ground, Diagnosis and Testing).
short circuit to power,
open circuit, high
resistance

P0483- Fan Performance - Signal The engine control Refer to electrical circuit diagrams and
37 frequency too high module detected check the viscous fan circuit for short
insufficient duration circuit to ground, short circuit to power,
for one cycle of the open circuit, high resistance
output across a If fault persists, refer to the relevant
specified sample size section of the workshop manual and
Engine cooling fan refer to the cooling fan pinpoint test
speed above maximum procedures For additional information,
threshold refer to: Engine Cooling (303-03B
Viscous fan circuit Engine Cooling - TDV6 3.0L Diesel,
short circuit to ground, Diagnosis and Testing).
short circuit to power,
open circuit, high
resistance

P0486- Exhaust Gas Recirculation The engine control This DTC is set when the engine control
13 Sensor B Circuit - Circuit module has module detects a no load error on the
open determined an open throttle motor position sensor circuit.
circuit via lack of bias This sensor is a potentiometer. Refer to
voltage, low current the electrical circuit diagrams and check
flow, no change in the the sensor 5 volt supply and ground
state of an input in circuits. Check the sensor circuits for
response to an output open circuits, short circuit to ground,
Harness failure - short circuit to power. Repair harness as
Throttle motor required. Using the Jaguar Land Rover
position sensor circuit approved diagnostic system, clear all
open circuit stored DTCs using the ‘Diagnosis
Throttle motor Menu’ tab and retest
position sensor failure Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new throttle motor
position sensor failure

P0486- Exhaust Gas Recirculation The engine control Refer to the electrical circuit diagrams
16 Sensor B Circuit - Circuit module measured a and check exhaust gas recirculation
voltage below threshold voltage below a valve B circuit for short circuit to
specified range but not ground, high resistance, open circuit,
necessarily a short disconnected. Repair harness as
circuit to ground required. Using the Jaguar Land Rover
Exhaust gas approved diagnostic system, clear all
recirculation valve stored DTCs using the ‘Diagnosis
bank 2 circuit short Menu’ tab and retest
circuit to ground, high Using the Jaguar Land Rover approved
resistance, open diagnostic system, perform routine -
circuit, disconnected Inline diagnostic unit 2 diagnostic test -
Exhaust gas Exhaust gas recirculation valve. Clear
recirculation valve the DTCs and retest
bank 2 failure Check and install new exhaust gas
recirculation valve B as required

P0486- Exhaust Gas Recirculation The engine control Refer to the electrical circuit diagrams
17 Sensor B Circuit - Circuit module measured a and check exhaust gas recirculation
voltage above threshold voltage above a valve bank 2 circuit for short circuit to
specified range but not power. Repair harness as required.
necessarily a short Using the Jaguar Land Rover approved
circuit to power diagnostic system, clear all stored DTCs
Exhaust gas using the ‘Diagnosis Menu’ tab and
recirculation valve retest
bank 2 circuit short Using the Jaguar Land Rover approved
circuit to power diagnostic system, perform routine -
Exhaust gas Inline diagnostic unit 2 diagnostic test -
recirculation valve Exhaust gas recirculation valve. Clear
bank 2 failure the DTCs and retest
Check and install new exhaust gas
recirculation valve bank 2 as required

P0486- Exhaust Gas Recirculation Throttle position Refer to the electrical circuit diagrams
92 Sensor B Circuit - sensor circuit short and check throttle position sensor circuit
Performance or incorrect circuit to ground, short for short circuit to ground, short circuit
operation circuit to power, high to power, high resistance, open circuit,
resistance, open disconnected. Repair harness as
circuit, disconnected required. Using the Jaguar Land Rover
Throttle position approved diagnostic system, clear all
sensor failure stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Check and install new throttle position
sensor as required
P0487- Exhaust Gas Recirculation Harness failure - Using the Jaguar Land Rover approved
00 Throttle Control Circuit A Throttle motor control diagnostic system, check datalogger
/Open - No sub type circuit open circuit, signals, Commanded Throttle Actuator
information short circuit to ground, Control (0xF44C). This DTC is set
short circuit to power when the engine control module detects
Throttle motor failure an open load error on the throttle motor
control circuit. Refer to the electrical
circuit diagrams and check the throttle
control circuits for open circuit, short
circuit to ground, short circuit to power.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new throttle motor
control actuator as required

P0487- Exhaust Gas Recirculation The engine control Using the Jaguar Land Rover approved
19 Throttle Control Circuit A module has measured diagnostic system, check datalogger
/Open - Circuit current current flow above a signals, Commanded Throttle Actuator
above threshold specified range Control (0xF44C). Refer to the
Harness failure - electrical circuit diagrams and check the
Throttle motor control throttle control circuits for short circuit
circuit short circuit to to ground, high resistance, open circuit.
ground, high Repair harness as required. Using the
resistance, open circuit Jaguar Land Rover approved diagnostic
Throttle motor failure system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new throttle motor
control actuator as required

P0487- Exhaust Gas Recirculation The engine control Using the Jaguar Land Rover approved
1D Throttle Control Circuit A module has detected a diagnostic system, check datalogger
/Open - Circuit current out current outside of the signals, Commanded Throttle Actuator
of range expected range, but Control (0xF44C). Refer to the
not identified as too electrical circuit diagrams and check the
high or too low throttle plate actuator control circuits for
Harness failure - short circuit to ground, short circuit to
Throttle motor control power, short circuit to other circuit.
circuit short circuit to Repair harness as required. Using the
ground, short circuit to Jaguar Land Rover approved diagnostic
power, short circuit to system, clear all stored DTCs using the
other circuit ‘Diagnosis Menu’ tab and retest
Throttle motor failure Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new throttle motor
control actuator as required

P0488- Exhaust Gas Recirculation The engine control Using the Jaguar Land Rover approved
16 Throttle Control Circuit A module measured a diagnostic system, check datalogger
Range/Performance - voltage below a signals, Commanded Throttle Actuator
Circuit voltage below specified range but not Control (0xF44C). Refer to the
threshold necessarily a short electrical circuit diagrams and check the
circuit to ground throttle plate actuator control circuits for
Harness failure - open circuit, short circuit to ground,
Throttle motor control short circuit to power, high resistance,
circuit open circuit, short circuit to other circuit. Repair
short circuit to ground, harness as required. Using the Jaguar
short circuit to power, Land Rover approved diagnostic
high resistance, short system, clear all stored DTCs using the
circuit to another ‘Diagnosis Menu’ tab and retest
circuit Using the Jaguar Land Rover approved
Throttle motor failure diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new throttle motor
control actuator as required

P0488- Exhaust Gas Recirculation The engine control Using the Jaguar Land Rover approved
19 Throttle Control Circuit A module has measured diagnostic system, check datalogger
Range/Performance - current flow above a signals, Commanded Throttle Actuator
Circuit current above specified range Control (0xF44C). Refer to the
threshold Harness failure - electrical circuit diagrams and check the
Throttle motor control throttle plate actuator control circuit for
circuit short circuit to short circuit to ground, high resistance.
ground, high Repair harness as required. Using the
resistance Jaguar Land Rover approved diagnostic
Throttle motor failure system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new throttle motor
control actuator as required

P0488- Exhaust Gas Recirculation The engine control Using the Jaguar Land Rover approved
1D Throttle Control Circuit A module has detected a diagnostic system, check datalogger
Range/Performance - current outside of the signals, Commanded Throttle Actuator
Circuit current out of range expected range, but Control (0xF44C). Refer to the
not identified as too electrical circuit diagrams and check the
high or too low throttle plate actuator control circuits for
Harness failure - high resistance, open circuit, short
Throttle motor control circuit to ground, short circuit to power,
circuit high resistance, short circuit to other circuit. Repair
open circuit, short harness as required. Using the Jaguar
circuit to ground, short Land Rover approved diagnostic
circuit to power, short system, clear all stored DTCs using the
circuit to other circuit ‘Diagnosis Menu’ tab and retest
Throttle motor failure Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new throttle motor
control actuator as required

P0488- Exhaust Gas Recirculation The engine control Using the Jaguar Land Rover approved
4B Throttle Control Circuit A module detected an diagnostic system, check datalogger
Range/Performance - Over internal temperature signals, Commanded Throttle Actuator
temperature above the expected Control (0xF44C). Refer to the
range electrical circuit diagrams and check the
Harness failure - throttle motor control circuit for short
Throttle motor control circuit to ground, short circuit to power,
circuit short circuit to high resistance. Repair harness as
ground, short circuit to required. Using the Jaguar Land Rover
power, high resistance approved diagnostic system, clear all
Throttle motor failure stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new throttle motor
control actuator as required

P0488- Exhaust Gas Recirculation Harness failure - Refer to the electrical circuit diagrams
72 Throttle Control Circuit A Exhaust gas and check the exhaust gas recirculation
Range/Performance - recirculation throttle throttle inlet control circuit for short
Actuator stuck open inlet control circuit circuit to ground, short circuit to power,
short circuit to ground, high resistance, open circuit. Repair
short circuit to power, harness as required. Using the Jaguar
high resistance, open Land Rover approved diagnostic
circuit system, clear all stored DTCs using the
Exhaust gas ‘Diagnosis Menu’ tab and retest
recirculation throttle Using the Jaguar Land Rover approved
inlet control actuator diagnostic system, perform routine -
failure Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new exhaust gas
recirculation throttle inlet control
actuator as required

P0488- Exhaust Gas Recirculation Harness failure - Refer to the electrical circuit diagrams
73 Throttle Control Circuit A Exhaust gas and check the exhaust gas recirculation
Range/Performance - recirculation throttle throttle inlet control circuit for short
Actuator stuck closed inlet control circuit circuit to ground, short circuit to power,
short circuit to ground, high resistance, open circuit. Repair
short circuit to power, harness as required. Using the Jaguar
high resistance, open Land Rover approved diagnostic
circuit system, clear all stored DTCs using the
Exhaust gas ‘Diagnosis Menu’ tab and retest
recirculation throttle Using the Jaguar Land Rover approved
inlet control actuator diagnostic system, perform routine -
failure Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new exhaust gas
recirculation throttle inlet control
actuator as required

P0489- Exhaust Gas Recirculation Throttle position Check for related DTCs and refer to the
77 Control Circuit Low - sensor circuit open relevant DTC index
Commanded position not circuit Refer to the electrical circuit diagrams
reachable and check the throttle position sensor
circuit for open circuit. Repair harness
as required. Using the Jaguar Land
Rover approved diagnostic system, clear
all stored DTCs using the ‘Diagnosis
Menu’ tab and retest

P0490- Exhaust Gas Recirculation Throttle position Check for related DTCs and refer to the
77 A Control Circuit High - sensor circuit, short relevant DTC index
Commanded position not circuit to ground, short Refer to the electrical circuit diagrams
reachable circuit to power, open and check the throttle position sensor
circuit circuit for short circuit to ground, short
circuit to power, open circuit. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest

P049D- Exhaust Gas Recirculation Harness failure - Refer to the electrical circuit diagrams
00 A Control Position Exhaust gas and check the bank 1 exhaust gas
Exceeded Learning Limit - recirculation valve recirculation control circuit for short
No sub type information bank 1 control circuit circuit to ground, short circuit to power,
short circuit to ground, high resistance, open circuit. Repair
short circuit to power, harness as required. Using the Jaguar
high resistance, open Land Rover approved diagnostic
circuit system, clear all stored DTCs using the
Exhaust gas ‘Diagnosis Menu’ tab and retest
recirculation valve Using the Jaguar Land Rover approved
bank 1 actuator failure diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new exhaust gas
recirculation control actuator as required

P049E- Exhaust Gas Recirculation Harness failure - Refer to the electrical circuit diagrams
00 B Control Position Exhaust gas and check the bank 2 exhaust gas
Exceeded Learning Limit - recirculation valve recirculation control circuit for short
No sub type information bank 2 control circuit circuit to ground, short circuit to power,
short circuit to ground, high resistance, open circuit. Repair
short circuit to power, harness as required. Using the Jaguar
high resistance, open Land Rover approved diagnostic
circuit system, clear all stored DTCs using the
Exhaust gas ‘Diagnosis Menu’ tab and retest
recirculation valve Using the Jaguar Land Rover approved
bank 2 actuator failure diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new exhaust gas
recirculation control actuator as required

P0504- Brake Switch A /B Brake pedal switch Check for related brake pressure DTCs
27 Correlation - Signal rate of plunger failure within the anti-lock brake system
change above threshold Brake pedal switch not control module
fitted correctly Check brake pedal switch is fitted
Brake switch A failure correctly. Clear DTC, start the engine
and press the brake pedal, using
maximum travel, for greater than 1
second taking care not to press the
accelerator pedal
Check and install new brake switch as
required

P0504- Brake Switch A /B Error check for brake Refer to the electrical circuit diagrams
62 Correlation - Signal plausibility and check brake pedal switch circuit for
compare failure Brake pedal switch short circuit to power, open circuit.
circuit short circuit to Repair harness as required. Using the
power, open circuit Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest

P050E- Cold Start Engine Exhaust Engine coolant Refer to the electrical circuit diagrams
00 Temperature Too Low - temperature sensor and check engine coolant temperature
No sub type information circuit short circuit to sensor circuit for short circuit to ground,
ground, short circuit to short circuit to power, open circuit,
power, open circuit, disconnected. Repair harness as
disconnected required. Using the Jaguar Land Rover
Engine coolant approved diagnostic system, clear all
temperature sensor stored DTCs using the ‘Diagnosis
failure Menu’ tab and retest
Check and install new engine coolant
temperature sensor as required

P050F- Brake Assist Vacuum Too Harness failure - Refer to the electrical circuit diagrams
00 Low - No sub type Vacuum switch circuit and check vacuum switch circuit for
information short circuit to ground, short circuit to ground, short circuit to
short circuit to power, power, open circuit, disconnected.
open circuit, Repair harness as required. Using the
disconnected Jaguar Land Rover approved diagnostic
Vacuum switch failure system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new vacuum switch as
required

P0512- Starter Request Circuit - The engine control This DTC is set when the engine control
24 Signal stuck high module measures a module detects the engine crank signal
signal that remains from the central junction box is stuck
high when transitions high. If this DTC is logged on its own
are expected clear the DTC Using the Jaguar Land
Harness failure - Rover approved diagnostic system,.
Starter request circuit Select PARK position. Set ignition OFF,
failure wait 2 minutes for post drive to
Central junction box complete. Set ignition ON but do NOT
failure crank. Wait 25 seconds. Crank engine
Post drive cycle not and check if DTC is cleared. If this DTC
completed is logged with lost communication
Harness failure - CAN DTCs refer to electrical circuit diagrams
circuit and check CAN circuit. If the engine
cannot be cranked read the DTCs stored
in the central junction box and refer to
the relevant DTC index. Check the
engine crank signal input circuit for
open circuit, short circuit to power,
short circuit to ground, short circuit to
other circuits. Repair harness as
required. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest

P0512- Starter Request Circuit - Harness failure - This DTC is set when the engine control
64 Signal plausibility failure Starter request circuit module detects the engine crank signal
failure from the passenger compartment fuse
Central junction box box is stuck high. If this DTC is logged
failure on its own clear the DTC Using the
Postdrive cycle not Jaguar Land Rover approved diagnostic
completed system,. Select PARK position. Set
Harness failure - CAN ignition OFF, wait 2 minutes for post
circuit drive to complete. Set ignition ON but
do NOT crank. Wait 25 seconds. Crank
engine and check if DTC is cleared. If
this DTC is logged with lost
communication DTCs refer to electrical
circuit diagrams and check CAN circuit.
If the engine cannot be cranked read the
DTCs stored in the central junction box
and refer to the relevant DTC index.
Check the engine crank signal input
circuit for open circuits, short circuit to
power, short circuit to ground, short to
other circuits. Repair wiring harness as
required, Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest system

P0513- Incorrect Immobilizer Key Security key invalid Check for CAN network and engine
00 - No sub type information control module related DTCs. Re-
configure the engine control module
Using the Jaguar Land Rover approved
diagnostic system,. Re-configure the
instrument cluster Using the Jaguar
Land Rover approved diagnostic
system,

P0528- Fan Speed Sensor Circuit Harness failure - Using the Jaguar Land Rover approved
00 No Signal - No sub type Cooling fan monitor diagnostic system, check datalogger
information circuit signals, Fan Speed Indicated (0x0702).
This DTC is set when the engine control
module does not receive a signal on the
cooling fan monitor circuit. Check the
cooling fan monitor signal input circuit
for open circuits, short circuit to power,
short circuit to ground or other circuits.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest

P052F- Glow Plug Control Module Glow plug control Refer to the electrical circuit diagrams
00 System Voltage - No sub module circuit short and check glow plug control module
type information circuit to ground, short circuit for short circuit to ground, short
circuit to power, open circuit to power, open circuit,
circuit, disconnected disconnected. Repair harness as
Glow plug control required. Using the Jaguar Land Rover
module failure approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Check and install new glow plug control
module as required

P0544- Exhaust Gas Temperature Exhaust gas Using the Jaguar Land Rover approved
00 Sensor Circuit - Bank 1 temperature sensor diagnostic system, check datalogger
Sensor 1 - No sub type post turbocharger bank signals, Exhaust Gas Temperature Bank
information 2, sensor 1 circuit 1 Sensor 1 Voltage (0x03BF), Exhaust
short circuit to ground Gas Temperature Bank 2 Sensor 1
Exhaust gas (0x03F7)
temperature sensor Refer to the electrical circuit diagrams
post turbocharger bank and check exhaust gas temperature
2, sensor 1 failure sensor post turbocharger bank 2, sensor
1 circuit for short circuit to ground.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new exhaust gas
temperature sensor post turbocharger -
bank 2, sensor 1 as required

P0545- Exhaust Gas Temperature Exhaust gas Refer to the electrical circuit diagrams
00 Sensor Circuit Low - Bank temperature sensor, and check exhaust gas temperature
1 Sensor 1 - No sub type bank 1 sensor 1 circuit sensor, bank 1 sensor 1 circuit for short
information short circuit to ground, circuit to ground, high resistance, open
high resistance, open circuit, disconnected. Repair harness as
circuit, disconnected required. Using the Jaguar Land Rover
Exhaust gas approved diagnostic system, clear all
temperature sensor, stored DTCs using the ‘Diagnosis
bank 1 sensor 1 failure Menu’ tab and retest
Check and install new exhaust gas
temperature sensor, bank 1 sensor 1 as
required

P0546- Exhaust Gas Temperature Exhaust gas Refer to the electrical circuit diagrams
00 Sensor Circuit High - Bank temperature sensor, and check exhaust gas temperature
1 Sensor 1 - No sub type bank 1 sensor 1 circuit sensor, bank 1 sensor 1 circuit for short
information short circuit to power circuit to power. Repair harness as
Exhaust gas required. Using the Jaguar Land Rover
temperature sensor, approved diagnostic system, clear all
bank 1 sensor 1 failure stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Check and install new exhaust gas
temperature sensor, bank1 sensor 1 as
required

P0547- Exhaust Gas Temperature Exhaust gas Refer to the electrical circuit diagrams
00 Sensor Circuit - Bank 2 temperature sensor and check exhaust gas temperature
Sensor 1 - No sub type post turbocharger sensor post turbocharger circuit for short
information short circuit to ground circuit to ground
Exhaust gas Clear the DTC and retest
temperature sensor Check and install new exhaust gas
post turbocharger temperature sensor post turbocharger as
failure required

P0548- Exhaust Gas Temperature Exhaust gas Refer to the electrical circuit diagrams
00 Sensor Circuit Low - Bank temperature sensor and check exhaust gas temperature
2 Sensor 1 - No sub type post turbocharger sensor post turbocharger circuit for short
information short circuit short circuit to ground, open circuit, high
circuit to ground, open resistance
circuit, high resistance Clear the DTC and retest
Exhaust gas Check and install new exhaust gas
temperature sensor temperature sensor post turbocharger as
post turbocharger required
failure

P0549- Exhaust Gas Temperature Exhaust gas Refer to the electrical circuit diagrams
00 Sensor Circuit High - Bank temperature sensor and check exhaust gas temperature
2 Sensor 1 - No sub type post turbocharger sensor post turbocharger circuit for short
information short circuit short circuit to power, open circuit, high
circuit to power, open resistance
circuit, high resistance Clear the DTC and retest
Exhaust gas Check and install new exhaust gas
temperature sensor temperature sensor post turbocharger as
post turbocharger required
failure

P0571- Brake Switch A Circuit - The brake switch Using the Jaguar Land Rover approved
62 Signal compare failure signal received over diagnostic system, carry out network
CAN is defective integrity test
Brake switch Check for related DTCs and refer to the
(footbrake switch) relevant DTC index
failure Check and install new brake switch as
required

P0571- Brake Switch A Circuit - Brake pedal pressed Ensure driver has not lightly pressed
68 Event information by driver at same time brake pedal and accelerator pedal at the
as accelerator pedal same time
pressed Refer to the electrical circuit diagrams
Brake pedal switch - and check Brake switch - Circuit
Circuit BOO_1 - Short BOO_1 - For short circuit to power.
circuit to power Repair wiring harness as required,
Brake switch Using the Jaguar Land Rover approved
(footbrake switch) diagnostic system, clear all stored DTCs
failure using the ‘Diagnosis Menu’ tab and
retest.
Check and install new brake switch as
required

P0575- Cruise Control Input The DTC sets if the Check speed control buttons are not
81 Circuit - Invalid serial data cancel, set minus, set jammed/contaminated/damaged. Check
received plus, resume, headway speed control module for related DTCs
increase and headway and refer to the relevant DTC index
decrease speed control
buttons have been
pressed for longer than
a calibrated period of
time. The system then
assumes a
stuck/damaged button
and will cancel and/or
disable cruise. The
failure will be healed
in the next driving
cycle if the failure is
removed

P0602- Powertrain Control Module Mismatch between car Using the Jaguar Land Rover approved
00 Programming Error - No configuration file and diagnostic system, re-configure the
sub type information engine control module engine control module. Using the Jaguar
calibration for Land Rover approved diagnostic
expected engine power system, clear all stored DTCs using the
output ‘Diagnosis Menu’ tab and retest
Incorrect engine
control module
calibration for vehicle
specification

P0605- Internal Control Module Corrupt engine control Using the Jaguar Land Rover approved
00 Read Only Memory module software flash diagnostic system, re-configure the
(ROM) Error - No sub type Engine control module engine control module
information power supply failure Refer to the electrical circuit diagrams
Engine control module and check the engine control module
ground supply failure power and ground supplies for open
Engine control module circuit. Repair harness as required.
failure Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new engine control
module as required

P0606- Control Module Processor Corrupt engine control Using the Jaguar Land Rover approved
00 - No sub type information module software flash diagnostic system, re-configure the
Engine control module engine control module
power supply failure Refer to the electrical circuit diagrams
Engine control module and check the engine control module
ground supply failure power and ground supplies for open
Engine control module circuit. Repair harness as required.
failure Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new engine control
module as required

P0606- Control Module Processor Corrupt engine control Using the Jaguar Land Rover approved
44 - Data memory failure module software flash diagnostic system, re-configure the
Engine control module engine control module
power supply failure Refer to the electrical circuit diagrams
Engine control module and check the engine control module
ground supply failure power and ground supplies for open
Engine control module circuit. Repair harness as required.
failure Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new engine control
module as required

P0606- Control Module Processor Corrupt engine control Using the Jaguar Land Rover approved
49 - Internal electronic failure module software flash diagnostic system, re-configure the
Engine control module engine control module
power supply failure Refer to the electrical circuit diagrams
Engine control module and check the engine control module
ground supply failure power and ground supplies for open
Engine control module circuit. Repair harness as required.
failure Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new engine control
module as required

P0607- Control Module Corrupt engine control Using the Jaguar Land Rover approved
00 Performance - No sub type module software flash diagnostic system, re-configure the
information Engine control module engine control module
power supply failure Refer to the electrical circuit diagrams
Engine control module and check the engine control module
failure power supply for open circuit. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new engine control
module as required

P060A- Internal Control Module Engine control module Check engine control module power and
00 Monitoring Processor has reset due to ground supply circuits for open circuits
Performance - No sub type hardware failure Re-configure the engine control module
information using the Jaguar Land Rover approved
diagnostic system
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new engine control
module as required

P060A- Internal Control Module The engine control Using the Jaguar Land Rover approved
16 Monitoring Processor module measured a diagnostic system, re-configure the
Performance - Circuit voltage below a engine control module
voltage below threshold specified range but not Refer to the electrical circuit diagrams
necessarily a short and check the engine control module
circuit to ground power supply for open circuit. Repair
Corrupt engine control harness as required. Using the Jaguar
module software flash Land Rover approved diagnostic
Engine control module system, clear all stored DTCs using the
power supply failure ‘Diagnosis Menu’ tab and retest
Engine control module Check and install new engine control
failure module as required

P060A- Internal Control Module The engine control Using the Jaguar Land Rover approved
17 Monitoring Processor module measured a diagnostic system, re-configure the
Performance - Circuit voltage above a engine control module
voltage above threshold specified range but not Refer to the electrical circuit diagrams
necessarily a short and check the engine control module
circuit to power power and ground supplies for open
Corrupt engine control circuit. Repair harness as required.
module software flash Using the Jaguar Land Rover approved
Engine control module diagnostic system, clear all stored DTCs
power supply failure using the ‘Diagnosis Menu’ tab and
Engine control module retest
ground supply failure Check and install new engine control
Engine control module module as required
failure

P060B- Internal Control Module Corrupt engine control Using the Jaguar Land Rover approved
00 A/D Processing module software flash diagnostic system, re-configure the
Performance - No sub type Engine control module engine control module
information power supply failure Refer to the electrical circuit diagrams
Engine control module and check the engine control module
ground supply failure power and ground supplies for open
Engine control module circuit. Repair harness as required.
failure Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new engine control
module as required

P060B- Internal Control Module The engine control Using the Jaguar Land Rover approved
16 A/D Processing module measured a diagnostic system, re-configure the
Performance - Circuit voltage below a engine control module
voltage below threshold specified range but not Refer to the electrical circuit diagrams
necessarily a short and check the engine control module
circuit to ground power supply for open circuit. Repair
Corrupt engine control harness as required. Using the Jaguar
module software flash Land Rover approved diagnostic
Engine control module system, clear all stored DTCs using the
power supply failure ‘Diagnosis Menu’ tab and retest
Engine control module Refer to the electrical circuit diagrams
ground supply failure and check the engine control module
Engine control module ground supply for open circuit. Repair
failure harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new engine control
module as required

P060B- Internal Control Module The engine control Using the Jaguar Land Rover approved
17 A/D Processing module measured a diagnostic system, re-configure the
Performance - Circuit voltage above a engine control module
voltage above threshold specified range but not Refer to the electrical circuit diagrams
necessarily a short and check the engine control module
circuit to power power supply for open circuit. Repair
Corrupt engine control harness as required. Using the Jaguar
module software flash Land Rover approved diagnostic
Engine control module system, clear all stored DTCs using the
power supply failure ‘Diagnosis Menu’ tab and retest
Engine control module Refer to the electrical circuit diagrams
ground supply failure and check the engine control module
Engine control module ground supply for open circuit. Repair
failure harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new engine control
module as required

P060B- Internal Control Module Corrupt engine control Using the Jaguar Land Rover approved
46 A/D Processing module software flash diagnostic system, re-configure the
Performance - Engine control module engine control module
Calibration/parameter power supply failure Refer to the electrical circuit diagrams
memory failure Engine control module and check the engine control module
ground supply failure power supply for open circuit. Repair
Engine control module harness as required. Using the Jaguar
failure Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Refer to the electrical circuit diagrams
and check the engine control module
ground supply for open circuit. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new engine control
module as required

P060B- Internal Control Module Corrupt engine control Using the Jaguar Land Rover approved
49 A/D Processing module software flash diagnostic system, re-configure the
Performance - Internal Engine control module engine control module
electronic failure power supply failure Refer to the electrical circuit diagrams
Engine control module and check the engine control module
ground supply failure power supply for open circuit. Repair
Engine control module harness as required. Using the Jaguar
failure Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Refer to the electrical circuit diagrams
and check the engine control module
ground supply for open circuit. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new engine control
module as required

P060B- Internal Control Module Corrupt engine control Using the Jaguar Land Rover approved
63 A/D Processing module software flash diagnostic system, re-configure the
Performance - Engine control module engine control module
Circuit/component power supply failure Refer to the electrical circuit diagrams
protection time-out Engine control module and check the engine control module
ground supply failure power supply for open circuit. Repair
Engine control module harness as required. Using the Jaguar
failure Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Refer to the electrical circuit diagrams
and check the engine control module
ground supply for open circuit. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new engine control
module as required

P060C- Internal Control Module Engine control module Clear DTC and road test vehicle
00 Main Processor has reset due to including at least 5 ignition cycles. Re-
Performance - No sub type hardware or software check DTC and repeat above procedure.
information failure If DTC resets check and install new
engine control module as required

P060D- Internal Control Module Accelerator pedal Refer to the electrical circuit diagrams
00 Accelerator Pedal Position position sensor circuit, and check the reference voltage and
Performance - No sub type short circuit to ground, ground connections to the accelerator
information short circuit to power, pedal position sensor. Check signal
high resistance, open circuits for high resistance, open
circuit circuits, short circuit to power, short
Accelerator pedal circuit to ground. Using the Jaguar Land
position sensor failure Rover approved diagnostic system, clear
Engine control module all stored DTCs using the ‘Diagnosis
failure Menu’ tab and retest
Check and install a accelerator pedal
position sensor as required
Check and install new engine control
module as required

P0610- Control Module Vehicle Corrupt engine control Using the Jaguar Land Rover approved
00 Options Error - No sub module software flash diagnostic system, re-configure the
type information Engine control module engine control module
power supply failure Refer to the electrical circuit diagrams
Engine control module and check the engine control module
ground supply failure power supply for open circuit. Repair
Engine control module harness as required. Using the Jaguar
failure Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Refer to the electrical circuit diagrams
and check the engine control module
ground supply for open circuit. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new engine control
module as required

P0615- Starter Relay Circuit - No Starter relay circuit Refer to the electrical circuit diagrams
00 sub type information failure and check starter relay circuit for short
circuit to ground, short circuit to power,
open circuit, high resistance

P061A- Internal Control Module Corrupt engine control Using the Jaguar Land Rover approved
00 Torque Performance - No module software flash diagnostic system, re-configure the
sub type information Engine control module engine control module
power supply failure Refer to the electrical circuit diagrams
Engine control module and check the engine control module
ground supply failure power supply's for open circuit. Repair
Engine control module wiring harness as required, Using the
failure Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest system
Refer to the electrical circuit diagrams
and check the engine control module
ground supply's for open circuit. Repair
wiring harness as required, Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest system
Check and install new engine control
module as required

P061B- Internal Control Module Corrupt engine control Using the Jaguar Land Rover approved
00 Torque Calculation module software flash diagnostic system, re-configure the
Performance - No sub type Engine control module engine control module
information power supply failure Refer to the electrical circuit diagrams
Engine control module and check the engine control module
ground supply failure power supply's for open circuit. Repair
Engine control module wiring harness as required, Using the
failure Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest system
Refer to the electrical circuit diagrams
and check the engine control module
ground supply's for open circuit. Repair
wiring harness as required, Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest system
Check and install new engine control
module as required

P061C- Internal Control Module Corrupt engine control Using the Jaguar Land Rover approved
00 Engine RPM Performance module software flash diagnostic system, re-configure the
- No sub type information Engine control module engine control module
power supply failure Refer to the electrical circuit diagrams
Engine control module and check the engine control module
ground supply failure power supply for open circuit. Repair
Engine control module harness as required. Using the Jaguar
failure Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Refer to the electrical circuit diagrams
and check the engine control module
ground supply for open circuit. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new engine control
module as required

P061C- Internal Control Module The engine control Refer to the electrical circuit diagrams
11 Engine RPM Performance module has detected a and check the power and ground
- Circuit short to ground ground measurement supplies to the engine control module
for a period longer
than expected or has
detected a ground
measurement when
another value was
expected
Internal failure within
engine control module
- Engine speed output
short to ground

P061C- Internal Control Module The engine control Refer to the electrical circuit diagrams
12 Engine RPM Performance module has detected a and check the power and ground
- Circuit short to battery vehicle power supplies to the engine control module
measurement for a
period longer than
expected or has
detected a vehicle
power measurement
when another value
was expected
Internal failure within
engine control module
- Engine speed output
short to power
P061C- Internal Control Module The engine control Refer to the electrical circuit diagrams
13 Engine RPM Performance module has and check the power and ground
- Circuit open determined an open supplies to the engine control module
circuit via lack of bias
voltage, low current
flow, no change in the
state of an input in
response to an output
Internal failure within
engine control module
- Engine speed output
open circuit

P0620- Generator Control Circuit - Electrical failure has Refer to the electrical circuit diagrams
00 No sub type information been detected by the and check the generator circuit, for short
generator and reported circuit to power, short circuit to ground,
to the engine control open circuit. Repair harness as required.
module by LIN bus Using the Jaguar Land Rover approved
Generator failure diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new generator as
required

P0627- Fuel Pump A Control The engine control NOTE:


13 Circuit /Open - Circuit module has
open determined an open When this DTC is set the engine control
circuit via lack of bias module limits engine torque to protect the
voltage, low current engine and avoid pulling air into the fuel
flow, no change in the system under high load
state of an input in
response to an output Check the operation of the lift pump
Wiring harness failure relay. Replace if required. Refer to the
between engine electrical circuit diagrams and check the
control module and fuel lift pump relay control circuit
central junction box between the engine control module and
Lift pump relay failure the central junction box for open circuit.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 non-intrusive
test - Low pressure fuel pump

P0628- Fuel Pump A Control The engine control NOTE:


11 Circuit Low - Circuit short module has detected a
to ground ground measurement When this DTC is set the fuel lift pump will
for a period longer run continuously when the ignition is on, even
than expected or has when the engine is stopped
detected a ground
measurement when Check the operation of the lift pump
another value was relay. Replace if required. Refer to the
expected electrical circuit diagrams and check the
Wiring harness failure fuel lift pump relay control circuit
between engine between the engine control module and
control module and the central junction box for a short
central junction box circuit to ground. Repair harness as
Lift pump relay failure required. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 non-intrusive
test - Low pressure fuel pump

P0629- Fuel Pump A Control The engine control NOTE:


12 Circuit High - Circuit short module has detected a
to battery vehicle power When this DTC is set the engine control
measurement for a module limits engine torque to protect the
period longer than engine and avoid pulling air into the fuel
expected or has system under high load
detected a vehicle
power measurement Check the operation of the lift pump
when another value relay. Replace if required. Refer to the
was expected electrical circuit diagrams and check the
Wiring harness failure fuel lift pump relay control circuit
between engine between the engine control module and
control module and the central junction box for a short
central junction box circuit to power. Repair harness as
Lift pump relay failure required. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 non-intrusive
test - Low pressure fuel pump

P062A- Fuel Pump A Control Lift pump relay has Check for related DTCs within the
92 Circuit Range/Performance been driven by the central junction box
- Performance or incorrect central junction box, Refer to the electrical circuit diagrams
operation but has not been and check fuel lift pump relay circuit for
requested by the short circuit to ground, short circuit to
engine control module power, open circuit. Using the Jaguar
Lift pump relay has Land Rover approved diagnostic
been requested by the system, clear all stored DTCs using the
engine control module, ‘Diagnosis Menu’ tab and retest
but has not been Refer to the electrical circuit diagrams
driven by the central and check between the engine control
junction box module and the rear junction box for
Wiring harness failure short circuit to ground. Using the Jaguar
lift pump monitor Land Rover approved diagnostic
circuit system, clear all stored DTCs using the
Lift pump relay ‘Diagnosis Menu’ tab and retest
Refer to the electrical circuit diagrams
and check the rear junction box to in
tank fuel pump relay for short circuit to
power. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 non-intrusive
test - Low pressure fuel pump
Check and install new fuel lift pump
relay as required. Using the Jaguar Land
Rover approved diagnostic system, clear
all stored DTCs using the ‘Diagnosis
Menu’ tab and retest

P062B- Internal Control Module Injector failure(s) Check for related injector DTCs and
00 Fuel Injector Control Corrupt engine control repair these first. Clear DTCs and retest
Performance - No sub type module software flash Using the Jaguar Land Rover approved
information Engine control module diagnostic system, re-configure the
power supply failure engine control module
Engine control module Refer to the electrical circuit diagrams
ground supply failure and check the engine control module
Engine control module power supply for open circuit. Repair
failure harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Refer to the electrical circuit diagrams
and check the engine control module
ground supply for open circuit. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new engine control
module as required

P062B- Internal Control Module Injector failure(s) Check for related injector DTCs and
41 Fuel Injector Control Corrupt engine control repair these first. Clear DTCs and retest
Performance - General module software flash Using the Jaguar Land Rover approved
checksum failure Engine control module diagnostic system, re-configure the
power supply failure engine control module
Engine control module Refer to the electrical circuit diagrams
ground supply failure and check the engine control module
Engine control module power supply for open circuit. Repair
failure harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Refer to the electrical circuit diagrams
and check the engine control module
ground supply for open circuit. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new engine control
module as required

P062B- Internal Control Module Injector failure(s) Check for related injector DTCs and
48 Fuel Injector Control Corrupt engine control repair these first. Clear DTCs and retest
Performance - Supervision module software flash Using the Jaguar Land Rover approved
software failure Engine control module diagnostic system, re-configure the
power supply failure engine control module
Engine control module Refer to the electrical circuit diagrams
ground supply failure and check the engine control module
Engine control module power supply for open circuit. Repair
failure harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Refer to the electrical circuit diagrams
and check the engine control module
ground supply for open circuit. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new engine control
module as required

P062B- Internal Control Module Injector failure(s) Check for related injector DTCs and
49 Fuel Injector Control Corrupt engine control repair these first. Clear DTCs and retest
Performance - Internal module software flash Using the Jaguar Land Rover approved
electronic failure Engine control module diagnostic system, re-configure the
power supply failure engine control module
Engine control module Refer to the electrical circuit diagrams
ground supply failure and check the engine control module
Engine control module power supply for open circuit. Repair
failure harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Refer to the electrical circuit diagrams
and check the engine control module
ground supply for open circuit. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new engine control
module as required

P062B- Internal Control Module Injector failure(s) Check for related injector DTCs and
61 Fuel Injector Control Corrupt engine control repair these first. Clear DTCs and retest
Performance - Signal module software flash Using the Jaguar Land Rover approved
calculation failure Engine control module diagnostic system, re-configure the
power supply failure engine control module
Engine control module Refer to the electrical circuit diagrams
ground supply failure and check the engine control module
Engine control module power supply for open circuit. Repair
failure harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Refer to the electrical circuit diagrams
and check the engine control module
ground supply for open circuit. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new engine control
module as required

P062B- Internal Control Module Injector failure(s) Check for related injector DTCs and
62 Fuel Injector Control Corrupt engine control repair these first. Clear DTCs and retest
Performance - Signal module software flash Using the Jaguar Land Rover approved
compare failure Engine control module diagnostic system, re-configure the
power supply failure engine control module
Engine control module Refer to the electrical circuit diagrams
ground supply failure and check the engine control module
Engine control module power supply for open circuit. Repair
failure harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Refer to the electrical circuit diagrams
and check the engine control module
ground supply for open circuit. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new engine control
module as required

P062B- Internal Control Module Injector failure(s) Check for related injector DTCs and
64 Fuel Injector Control Corrupt engine control repair these first. Clear DTCs and retest
Performance - Signal module software flash Using the Jaguar Land Rover approved
plausibility failure Engine control module diagnostic system, re-configure the
power supply failure engine control module
Engine control module Refer to the electrical circuit diagrams
ground supply failure and check the engine control module
Engine control module power supply for open circuit. Repair
failure harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Refer to the electrical circuit diagrams
and check the engine control module
ground supply for open circuit. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new engine control
module as required

P062B- Internal Control Module Injector failure(s) Check for related injector DTCs and
67 Fuel Injector Control Corrupt engine control repair these first. Clear DTCs and retest
Performance - Signal module software flash Using the Jaguar Land Rover approved
incorrect after event Engine control module diagnostic system, re-configure the
power supply failure engine control module
Engine control module Refer to the electrical circuit diagrams
ground supply failure and check the engine control module
Engine control module power supply for open circuit. Repair
failure harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Refer to the electrical circuit diagrams
and check the engine control module
ground supply for open circuit. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new engine control
module as required

P062B- Internal Control Module Injector failure(s) Check for related injector DTCs and
91 Fuel Injector Control Corrupt engine control repair these first. Clear DTCs and retest
Performance - Parametric module software flash Using the Jaguar Land Rover approved
Engine control module diagnostic system, re-configure the
power supply failure engine control module
Engine control module Refer to the electrical circuit diagrams
ground supply failure and check the engine control module
Engine control module power supply for open circuit. Repair
failure harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Refer to the electrical circuit diagrams
and check the engine control module
ground supply for open circuit. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new engine control
module as required

P062B- Internal Control Module Injector failure(s) Check for related injector DTCs and
92 Fuel Injector Control Corrupt engine control repair these first. Clear DTCs and retest
Performance - Performance module software flash Using the Jaguar Land Rover approved
or incorrect operation Engine control module diagnostic system, re-configure the
power supply failure engine control module
Engine control module Refer to the electrical circuit diagrams
ground supply failure and check the engine control module
Engine control module power supply for open circuit. Repair
failure harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Refer to the electrical circuit diagrams
and check the engine control module
ground supply for open circuit. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new engine control
module as required

P062B- Internal Control Module Injector failure(s) Check for related injector DTCs and
94 Fuel Injector Control Corrupt engine control repair these first. Clear DTCs and retest
Performance - Unexpected module software flash Using the Jaguar Land Rover approved
operation Engine control module diagnostic system, re-configure the
power supply failure engine control module
Engine control module Refer to the electrical circuit diagrams
ground supply failure and check the engine control module
Engine control module power supply for open circuit. Repair
failure harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Refer to the electrical circuit diagrams
and check the engine control module
ground supply for open circuit. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new engine control
module as required

P062B- Internal Control Module Injector failure(s) Check for related injector DTCs and
9A Fuel Injector Control Corrupt engine control repair these first. Clear DTCs and retest
Performance - Component module software flash Using the Jaguar Land Rover approved
or system operating Engine control module diagnostic system, re-configure the
conditions power supply failure engine control module
Engine control module Refer to the electrical circuit diagrams
ground supply failure and check the engine control module
Engine control module power supply for open circuit. Repair
failure harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Refer to the electrical circuit diagrams
and check the engine control module
ground supply for open circuit. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new engine control
module as required

P062D- Fuel Injector Driver Circuit Bank 1 injector Check for related injector DTCs. Check
00 Performance Bank 1 - No circuit(s) high injector connections to bank 1 cylinders.
sub type information resistance, short circuit Refer to the electrical circuit diagrams
to ground, short circuit and check bank 1 injector circuits for
to power, open circuit, short circuit to ground, short circuit to
disconnected power, open circuit, high resistance.
Injector bank 1 failure Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new injector(s) as
required

P062D- Fuel Injector Driver Circuit The engine control Refer to the electrical circuit diagrams
11 Performance Bank 1 - module has detected a and check the wiring harness between
Circuit short to ground ground measurement engine control module and bank 1 fuel
for a period longer injectors for short circuit to ground
than expected or has
detected a ground
measurement when
another value was
expected
Wiring harness failure
- Short circuit to
ground

P062D- Fuel Injector Driver Circuit The engine control Check for related injector DTCs. Check
16 Performance Bank 1 - module measured a injector connections to bank 1 cylinders.
Circuit voltage below voltage below a Refer to the electrical circuit diagrams
threshold specified range but not and check bank 1 injector circuits for
necessarily a short short circuit to ground, open circuit,
circuit to ground high resistance. Using the Jaguar Land
Bank 1 injector Rover approved diagnostic system, clear
circuit(s) high all stored DTCs using the ‘Diagnosis
resistance, short circuit Menu’ tab and retest
to ground, high Check and install new injector(s) as
resistance, open required
circuit, disconnected
Injector bank 1 failure

P062D- Fuel Injector Driver Circuit The engine control Check for related injector DTCs. Check
17 Performance Bank 1 - module measured a injector connections to bank 1 cylinders.
Circuit voltage above voltage above a Refer to the electrical circuit diagrams
threshold specified range but not and check bank 1 injector circuits for
necessarily a short short circuit to power. Using the Jaguar
circuit to power Land Rover approved diagnostic
Bank 1 injector system, clear all stored DTCs using the
circuit(s) short circuit ‘Diagnosis Menu’ tab and retest
to power Check and install new injector(s) as
Injector bank 1 failure required

P062E- Fuel Injector Driver Circuit Bank 2 injector Check for related injector DTCs. Check
00 Performance Bank 2 - No circuit(s) high injector connections to bank 2 cylinders.
sub type information resistance, short circuit Refer to the electrical circuit diagrams
to ground, short circuit and check bank 2 injector circuits for
to power, high short circuit to ground, short circuit to
resistance, open power, open circuit, high resistance.
circuit, disconnected Using the Jaguar Land Rover approved
Injector bank 2 failure diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new injector(s) as
required

P062E- Fuel Injector Driver Circuit The engine control Refer to the electrical circuit diagrams
11 Performance Bank 2 - module has detected a and check the wiring harness between
Circuit short to ground ground measurement engine control module and bank 2 fuel
for a period longer injectors for short circuit to ground
than expected or has
detected a ground
measurement when
another value was
expected
Wiring harness failure
- Short circuit to
ground

P062E- Fuel Injector Driver Circuit The engine control Check for related injector DTCs. Check
17 Performance Bank 2 - module measured a injector connections to bank 2 cylinders.
Circuit voltage above voltage above a Refer to the electrical circuit diagrams
threshold specified range but not and check bank 2 injector circuits for
necessarily a short short circuit to power. Using the Jaguar
circuit to power Land Rover approved diagnostic
Bank 2 injector system, clear all stored DTCs using the
circuit(s) short circuit ‘Diagnosis Menu’ tab and retest
to power Check and install new injector(s) as
Injector bank 2 failure required

P0633- Immobilizer Key Not Security key not Check for CAN network
00 Programmed - ECM/PCM programmed interference/engine control module
- No sub type information related errors. Re-configure the engine
control module Using the Jaguar Land
Rover approved diagnostic system,. Re-
configure the instrument cluster Using
the Jaguar Land Rover approved
diagnostic system,

P0634- Control Module Internal Engine control module Clear DTC, wait 10 minutes and retest
1B Temperature "A" Too High internal temperature Check and install new engine control
- Circuit resistance above too high module as required
threshold Engine control module
failure

P064C- Glow Plug Control Module Glow plug control Refer to the electrical circuit diagrams
00 - No sub type information module circuit short and check glow plug control module
circuit to ground, short circuit for short circuit to ground, short
circuit to power, open circuit to power, open circuit,
circuit, disconnected disconnected. Using the Jaguar Land
Glow plug control Rover approved diagnostic system, clear
module failure all stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Check and install new glow plug control
module as required

P064D- Internal Control Module Heated oxygen sensor Check and repair related heated oxygen
00 O2 Sensor Processor circuit short circuit to sensor DTCs. Refer to the electrical
Performance - Bank 1 - No ground, short circuit to circuit diagrams and check heated
sub type information power, high resistance, oxygen sensor for short circuit to
open circuit ground, short circuit to power, high
Heated oxygen sensor resistance, open circuit
failure Check and install new heated oxygen
Engine control module sensor as required. Using the Jaguar
failure Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new engine control
module as required

P064D- Internal Control Module The engine control Check and repair related heated oxygen
16 O2 Sensor Processor module measured a sensor DTCs. Refer to the electrical
Performance - Bank 1 - voltage below a circuit diagrams and check heated
Circuit voltage below specified range but not oxygen sensor for short circuit to
threshold necessarily a short ground, high resistance, open circuit
circuit to ground Check and install new heated oxygen
Heated oxygen sensor sensor as required. Using the Jaguar
circuit short circuit to Land Rover approved diagnostic
ground, high system, clear all stored DTCs using the
resistance, open circuit ‘Diagnosis Menu’ tab and retest
Heated oxygen sensor Check and install new engine control
failure module as required
Engine control module
failure

P0658- Actuator Supply Voltage A Actuator supply circuit Using the Jaguar Land Rover approved
00 Circuit Low - No sub type voltage below diagnostic system, perform the (Turbo,
information threshold EGR and air path dynamic test) routine
Refer to the electrical circuit diagrams
and check engine control module power
and ground supplies for short circuit to
ground, open circuit

P0659- Actuator Supply Voltage A Actuator supply circuit Using the Jaguar Land Rover approved
00 Circuit High - No sub type voltage above diagnostic system, perform the (Turbo,
information threshold EGR and air path dynamic test) routine
Refer to the electrical circuit diagrams
and check engine control module power
and ground supplies for short circuit to
power

P065A- Generator System Generator circuit short Refer to the electrical circuit diagrams
00 Performance - No sub type circuit to ground, high and check generator circuit for short
information resistance, open circuit circuit to ground, high resistance, open
Generator mechanical circuit. Repair harness as required.
failure Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new generator as
required

P065B- Generator Control Circuit The engine control Refer to the electrical circuit diagrams
16 Range/Performance - module measured a and check charging circuit for short
Circuit voltage below voltage below a circuit to ground, short circuit to power,
threshold specified range but not open circuit. Clear DTC and repeat
necessarily a short automated diagnostic procedure Using
circuit to ground the Jaguar Land Rover approved
Charging circuit short diagnostic system,
circuit to ground, short If DTC remains check battery is in fully
circuit to power, open charged and in a serviceable condition
circuit using the Midtronics battery tester and
Quiescent current high battery care manual. If ok suspect the
Battery failure/worn generator
out Check and install new generator as
Generator failure required

P065B- Generator Control Circuit The engine control Refer to the electrical circuit diagrams
17 Range/Performance - module measured a and check generator circuit for short
Circuit voltage above voltage above a circuit to ground, high resistance, open
threshold specified range but not circuit. Repair harness as required.
necessarily a short Using the Jaguar Land Rover approved
circuit to power diagnostic system, clear all stored DTCs
Generator circuit short using the ‘Diagnosis Menu’ tab and
circuit to ground, high retest
resistance, open circuit Check and install new generator as
Generator mechanical required
failure

P0668- Control Module Internal Engine control module Check and install new engine control
00 Temperature Sensor "A" internal temperature module as required
Circuit Low - No sub type sensor failure
information
P0669- Control Module Internal Engine control module Check and install new engine control
00 Temperature Sensor "A" internal temperature module as required
Circuit High - No sub type sensor failure
information
P066A- Cylinder 1 Glow Plug The engine control Refer to the electrical circuit diagrams
00 Control Circuit Low - No module has detected a and check the glow plug control circuit
sub type information ground measurement between the glow plug control module
for a period longer and the glow plug connector for short
than expected or has circuit to ground, check the power
detected a ground supply and ground connections to the
measurement when glow plug control module. Repair
another value was harness as required. Refer to relevant
expected section of workshop manual, check
Cylinder 1 glow plug cylinder 1 glow plug for internal short
circuit short circuit to circuit to ground. Replace glow plug if
ground required. Using the Jaguar Land Rover
Glow plug failure approved diagnostic system, clear all
Glow plug control stored DTCs using the ‘Diagnosis
module failure Menu’ tab and retest
Check and install new glow plug control
module

P066C- Cylinder 2 Glow Plug The engine control Refer to the electrical circuit diagrams
00 Control Circuit Low - No module has detected a and check the glow plug control circuit
sub type information ground measurement between the glow plug control module
for a period longer and the glow plug connector for short
than expected or has circuit to ground, check the power
detected a ground supply and ground connections to the
measurement when glow plug control module. Repair
another value was harness as required. Refer to relevant
expected section of workshop manual, check
Cylinder 2 glow plug cylinder 2 glow plug for internal short
circuit short circuit to circuit to ground. Replace glow plug if
ground required. Using the Jaguar Land Rover
Glow plug failure approved diagnostic system, clear all
Glow plug control stored DTCs using the ‘Diagnosis
module failure Menu’ tab and retest
Check and install new glow plug control
module

P066E- Cylinder 3 Glow Plug The engine control Refer to the electrical circuit diagrams
00 Control Circuit Low - No module has detected a and check the glow plug control circuit
sub type information ground measurement between the glow plug control module
for a period longer and the glow plug connector for short
than expected or has circuit to ground, check the power
detected a ground supply and ground connections to the
measurement when glow plug control module. Repair
another value was harness as required. Refer to relevant
expected section of workshop manual, check
Cylinder 3 glow plug cylinder 3 glow plug for internal short
circuit short circuit to circuit to ground. Replace glow plug if
ground required. Using the Jaguar Land Rover
Glow plug failure approved diagnostic system, clear all
Glow plug control stored DTCs using the ‘Diagnosis
module failure Menu’ tab and retest
Check and install new glow plug control
module

P0671- Cylinder 1 Glow Plug Glow plug control Refer to the electrical circuit diagrams
00 Circuit /Open - No sub circuit open circuit, and check glow plug circuit for open
type information high resistance circuit, high resistance. Repair wiring
Glow plug control harness as required, Using the Jaguar
connector Land Rover approved diagnostic
disconnected system, clear all stored DTCs using the
Glow plug failure ‘Diagnosis Menu’ tab and retest system
Check glow plug connector is correctly
connected, Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest system
Check and install new glow plug as
required

P0672- Cylinder 2 Glow Plug Glow plug control Refer to the electrical circuit diagrams
00 Circuit /Open - No sub circuit open circuit, and check glow plug circuit for open
type information high resistance circuit, high resistance. Repair wiring
Glow plug control harness as required, Using the Jaguar
connector Land Rover approved diagnostic
disconnected system, clear all stored DTCs using the
Glow plug failure ‘Diagnosis Menu’ tab and retest system
Check glow plug connector is correctly
connected, Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest system
Check and install new glow plug as
required

P0673- Cylinder 3 Glow Plug Glow plug control Refer to the electrical circuit diagrams
00 Circuit /Open - No sub circuit open circuit, and check glow plug circuit for open
type information high resistance circuit, high resistance. Repair wiring
Glow plug control harness as required, Using the Jaguar
connector Land Rover approved diagnostic
disconnected system, clear all stored DTCs using the
Glow plug failure ‘Diagnosis Menu’ tab and retest system
Check glow plug connector is correctly
connected, Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest system
Check and install new glow plug as
required

P0674- Cylinder 4 Glow Plug Glow plug control Refer to the electrical circuit diagrams
00 Circuit /Open - No sub circuit open circuit, and check glow plug circuit for open
type information high resistance circuit, high resistance. Repair wiring
Glow plug control harness as required, Using the Jaguar
connector Land Rover approved diagnostic
disconnected system, clear all stored DTCs using the
Glow plug failure ‘Diagnosis Menu’ tab and retest system
Check glow plug connector is correctly
connected, Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest system
Check and install new glow plug as
required

P0675- Cylinder 5 Glow Plug Glow plug control Refer to the electrical circuit diagrams
00 Circuit /Open - No sub circuit open circuit, and check glow plug circuit for open
type information high resistance circuit, high resistance. Repair wiring
Glow plug control harness as required, Using the Jaguar
connector Land Rover approved diagnostic
disconnected system, clear all stored DTCs using the
Glow plug failure ‘Diagnosis Menu’ tab and retest system
Check glow plug connector is correctly
connected, Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest system
Check and install new glow plug as
required

P0676- Cylinder 6 Glow Plug Glow plug control Refer to the electrical circuit diagrams
00 Circuit /Open - No sub circuit open circuit, and check glow plug circuit for open
type information high resistance circuit, high resistance. Repair wiring
Glow plug control harness as required, Using the Jaguar
connector Land Rover approved diagnostic
disconnected system, clear all stored DTCs using the
Glow plug failure ‘Diagnosis Menu’ tab and retest system
Check glow plug connector is correctly
connected, Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest system
Check and install new glow plug as
required
P067A- Cylinder 4 Glow Plug The engine control Refer to the electrical circuit diagrams
00 Control Circuit Low - No module has detected a and check the glow plug control circuit
sub type information ground measurement between the glow plug control module
for a period longer and the glow plug connector for short
than expected or has circuit to ground, check the power
detected a ground supply and ground connections to the
measurement when glow plug control module. Repair
another value was harness as required. Refer to relevant
expected section of workshop manual, check
Cylinder 4 glow plug cylinder 4 glow plug for internal short
circuit short circuit to circuit to ground. Replace glow plug if
ground required. Using the Jaguar Land Rover
Glow plug failure approved diagnostic system, clear all
Glow plug control stored DTCs using the ‘Diagnosis
module failure Menu’ tab and retest
Check and install new glow plug control
module

P067C- Cylinder 5 Glow Plug The engine control Refer to the electrical circuit diagrams
00 Control Circuit Low - No module has detected a and check the glow plug control circuit
sub type information ground measurement between the glow plug control module
for a period longer and the glow plug connector for short
than expected or has circuit to ground, check the power
detected a ground supply and ground connections to the
measurement when glow plug control module. Repair
another value was harness as required. Refer to relevant
expected section of workshop manual, check
Cylinder 5 glow plug cylinder 5 glow plug for internal short
circuit short circuit to circuit to ground. Replace glow plug if
ground required. Using the Jaguar Land Rover
Glow plug failure approved diagnostic system, clear all
Glow plug control stored DTCs using the ‘Diagnosis
module failure Menu’ tab and retest
Check and install new glow plug control
module

P067E- Cylinder 6 Glow Plug The engine control Refer to the electrical circuit diagrams
00 Control Circuit Low - No module has detected a and check the glow plug control circuit
sub type information ground measurement between the glow plug control module
for a period longer and the glow plug connector for short
than expected or has circuit to ground, check the power
detected a ground supply and ground connections to the
measurement when glow plug control module, ensure that
another value was the harness is checked for intermittent
expected failures. Repair harness as required.
Cylinder 6 glow plug Refer to relevant section of workshop
circuit short circuit to manual, check cylinder 6 glow plug for
ground internal short circuit to ground. Replace
Glow plug failure glow plug if required. Using the Jaguar
Glow plug control Land Rover approved diagnostic
module failure system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new glow plug control
module

P0683- Glow Plug Control Module Engine control module This DTC is set when the data
00 to PCM Communication to glow plug control transmission on the control circuit
Circuit - No sub type module circuit failure between the engine control module and
information Glow plug control the glow plug control module has an
module failure error. Check for other related DTCs and
Engine control module refer to the relevant DTC index. Refer
failure to the electrical circuit diagrams and
check the glowplug control signal line
from the engine control module to the
glow plug control module for failures
such as intermittent open circuits, high
resistance, short circuit to ground, short
circuit to power. Check the glowplug
monitor signal line from the glowplug
control module to the engine control
module for intermittent open circuits,
high resistance, short circuit to ground,
short circuit to power
Refer to the electrical circuit diagrams
and check power and ground supplies to
the glowplug control module. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new engine control
module as required

P068A- ECM/PCM Power Relay Vehicle battery This DTC is set when the engine
00 De-Energized - Too Early - disconnected before management system high current relay
No sub type information engine management contacts open early - Indicating a power
system relay has hold failure. Check the vehicle battery
powered down has not been disconnected before the
Engine management engine management system relay has
system high current powered down. Check the operation of
relay failure the engine management system high
Central junction box current relay. Refer to the electrical
failure circuit diagrams and check the engine
Harness failure - Relay management system high current relay
control circuit supply and control circuits for open
circuits, high resistance, short circuit to
ground, short circuit to power, short
circuit to other circuits. Repair harness
as required. Using the Jaguar Land
Rover approved diagnostic system, clear
all stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Check and install new relay or central
junction box as required

P06AF- Torque Management Injection cut off Check for related engine control module
00 System - Forced Engine demand for shut off DTCs and repair these first. Clear the
Shutdown - No sub type coordinator DTC and retest
information The DTC sets when
the engine speed has
exceeded the hard
engine speed limiter.
When this DTC sets, a
request to the shut-off
coordinator is made
for a reversible shut-
off of the injection
power stages, ensuring
no injections take
place. It is reset when
engine speed falls less
than or equal to the
hard limiter
Engine run away
Excessive injected fuel
Over boost from a
turbocharger

P0700- Transmission Control MIL request by Check transmission control module for
00 System (MIL Request) - automatic gearbox DTCs and refer to the relevant DTC
No sub type information HS CAN network, index. Using the Jaguar Land Rover
short circuit to power, approved diagnostic system, clear all
short circuit to ground, stored DTCs using the ‘Diagnosis
open circuit Menu’ tab and retest
If this DTC is logged with other HS
CAN related DTCs refer to the electrical
circuit diagrams and check HS CAN
network for short circuit to power, short
circuit to ground, open circuit

P0850- Park /Neutral Switch Input Hardwired Refer to the electrical circuit diagrams
64 Circuit - Signal plausibility park/neutral switch and check the park/neutral switch
failure does not match the circuit, for short circuit to power, short
information within the circuit to ground, open circuit
CAN signal If this DTC is logged with other HS
Park/neutral switch CAN related DTCs refer to the electrical
circuit, short circuit to circuit diagrams and check HS CAN
power, short circuit to network for short circuit to power, short
ground, open circuit circuit to ground, open circuit
HS CAN network
failure

P0A09- DC/DC Converter Status The engine control Refer to the electrical circuit diagrams
16 Circuit Low - Circuit module measured a and check the engine control module
voltage below threshold voltage below a power supply for open circuit. Repair
specified range but not harness as required. Using the Jaguar
necessarily a short Land Rover approved diagnostic
circuit to ground system, clear all stored DTCs using the
Engine control module ‘Diagnosis Menu’ tab and retest
power supply failure Refer to the electrical circuit diagrams
Engine control module and check the engine control module
ground supply failure ground supply for open circuit. Repair
Engine control module harness as required. Using the Jaguar
failure Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new engine control
module as required
P0A0F- Engine Failed to Start - No Engine control module Check for related engine control module
00 sub type information has logged an DTCs and repair these first. Using the
extended crank with Jaguar Land Rover approved diagnostic
no engine start system, clear all stored DTCs using the
Harness failure - ‘Diagnosis Menu’ tab and retest
Starter motor circuit Refer to the electrical circuit diagrams
and relays and check the starter motor circuit for
Vehicle battery failure short circuit to ground, short circuit to
Starter motor power, open circuit, high resistance
mechanical failure Refer to the workshop manual and the
battery care manual, inspect the vehicle
battery and ensure it is fully charged and
serviceable before performing further
tests
Check Starter motor for mechanical
failure. Install a new starter motor as
required

P0A0F- Engine Failed to Start - Vehicle battery failure Refer to the workshop manual and the
71 Actuator stuck Jammed starter motor battery care manual, inspect the vehicle
battery and ensure it is fully charged and
serviceable before performing further
tests
Check for a jammed or damaged starter
motor. Install a new starter motor as
required

P0A10- DC/DC Converter Status The engine control Using the Jaguar Land Rover approved
17 Circuit High - Circuit module measured a diagnostic system, re-configure the
voltage above threshold voltage above a engine control module
specified range but not Refer to the electrical circuit diagrams
necessarily a short and check the engine control module
circuit to power power supply for open circuit. Repair
Corrupt engine control harness as required. Using the Jaguar
module software flash Land Rover approved diagnostic
Engine control module system, clear all stored DTCs using the
power supply failure ‘Diagnosis Menu’ tab and retest
Engine control module Refer to the electrical circuit diagrams
ground supply failure and check the engine control module
Engine control module ground supply for open circuit. Repair
failure harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new engine control
module as required

P0A14- Engine Mount Control A The engine control Refer to the electrical circuit diagrams
13 Circuit /Open - Circuit module has and check the active engine mount
open determined an open solenoid control circuit for open circuit.
circuit via lack of bias Repair harness as required. Using the
voltage, low current Jaguar Land Rover approved diagnostic
flow, no change in the system, clear all stored DTCs using the
state of an input in ‘Diagnosis Menu’ tab and retest
response to an output
Wiring harness failure
- Active engine mount
solenoid circuit

P0A15- Engine Mount Control A The engine control Refer to the electrical circuit diagrams
11 Circuit Low - Circuit short module has detected a and check the active engine mount
to ground ground measurement solenoid control circuit for short circuit
for a period longer to ground. Repair harness as required.
than expected or has Using the Jaguar Land Rover approved
detected a ground diagnostic system, clear all stored DTCs
measurement when using the ‘Diagnosis Menu’ tab and
another value was retest
expected
Wiring harness failure
- Active engine mount
solenoid circuit

P0A16- Engine Mount Control A The engine control Refer to the electrical circuit diagrams
12 Circuit High - Circuit short module has detected a and check the active engine mount
to battery vehicle power solenoid control circuit for short circuit
measurement for a to power. Repair harness as required.
period longer than Using the Jaguar Land Rover approved
expected or has diagnostic system, clear all stored DTCs
detected a vehicle using the ‘Diagnosis Menu’ tab and
power measurement retest
when another value
was expected
Wiring harness failure
- Active engine mount
solenoid circuit

P0A16- Engine Mount Control A Active engine mount Refer to the electrical circuit diagrams
4B Circuit High - Over solenoid circuit short and check active engine mount solenoid
temperature circuit to ground, short circuit for short circuit to ground,
circuit to power power. Repair harness as required.
Active engine mount Using the Jaguar Land Rover approved
solenoid failure diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new engine mount
control vacuum solenoid as required

P0A1A- Generator Control Module Generator to engine Check for good/clean contact at
00 - No sub type information control module LIN generator and engine control module
circuit, open circuit LIN circuit connectors/pins. Refer to the
Generator/engine electrical circuit diagrams and check
control module failure generator to engine control module LIN
circuit for open circuit. Check for
engine control module hardware DTCs
and refer to relevant DTC index. Clear
DTCs and repeat automated diagnostic
procedure Using the Jaguar Land Rover
approved diagnostic system,
Check and install new generator /engine
control module as required

P0A1A- Generator Control Module Generator to engine Check for good/clean contact at
87 - Missing message control module LIN generator and engine control module
circuit open circuit LIN circuit connectors/pins. Refer to the
electrical circuit diagrams and check
generator to engine control module LIN
circuit for open circuit. Check for
engine control module hardware DTCs
and refer to relevant DTC index. Clear
DTCs and repeat automated diagnostic
procedure Using the Jaguar Land Rover
approved diagnostic system,

P0A3B- Generator Over Generator Check the generator wiring and


00 Temperature - No sub type wiring/connectors heat connectors for heat damage
information damaged Refer to the electrical circuit diagrams
Generator circuit short and check generator wiring for short
circuit to ground, high circuit to ground, high resistance. Repair
resistance harness as required. Using the Jaguar
Generator failure Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new generator as
required

P0A94- DC/DC Converter Corrupt engine control Using the Jaguar Land Rover approved
00 Performance - No sub type module software flash diagnostic system, re-configure the
information Engine control module engine control module
power supply failure Refer to the electrical circuit diagrams
Engine control module and check the engine control module
ground supply failure power supply for open circuit. Repair
Engine control module harness as required. Using the Jaguar
failure Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Refer to the electrical circuit diagrams
and check the engine control module
ground supply for open circuit. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new engine control
module as required

P115A- Low Fuel Level - Forced Low level fuel Check the fuel level, add fuel if
00 Limited Power - No sub condition required. Using the Jaguar Land Rover
type information Fuel level sensor approved diagnostic system, clear all
signal circuit - Short stored DTCs using the ‘Diagnosis
circuit to ground, short Menu’ tab and retest
circuit to power, open If there is sufficient fuel, refer to the
circuit electrical circuit diagrams and check the
Fuel level sensor fuel level sensor circuits for short, open
failure circuit. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new fuel level sensor
as required
P115A- Low Fuel Level - Forced Low level fuel Check the fuel level, add fuel if
68 Limited Power - Event condition required. Using the Jaguar Land Rover
information Fuel level sensor approved diagnostic system, clear all
signal circuit - Short stored DTCs using the ‘Diagnosis
circuit to ground, short Menu’ tab and retest
circuit to power, open If there is sufficient fuel, refer to the
circuit electrical circuit diagrams and check the
Fuel level sensor fuel level sensor circuits for short, open
failure circuit. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new fuel level sensor
as required

P115B- Low Fuel Level - Forced Low level fuel Check the fuel level, add fuel if
00 Engine Shutdown - No sub condition enabling run required. Using the Jaguar Land Rover
type information dry strategy approved diagnostic system, clear all
Fuel level sensor stored DTCs using the ‘Diagnosis
signal circuit - Short Menu’ tab and retest
circuit to ground, short If there is sufficient fuel, refer to the
circuit to power, open electrical circuit diagrams and check the
circuit fuel level sensor circuits for short, open
Fuel level sensor circuit. Repair harness as required.
failure Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new fuel level sensor
as required

P115F- Electronic Control Module The engine control Refer to the electrical circuit diagrams
11 Cooling Fan Circuit - module has detected a and check the engine control module
Circuit short to ground ground measurement cooling fan circuit for short circuit to
for a period longer ground. Repair harness as required.
than expected or has Using the Jaguar Land Rover approved
detected a ground diagnostic system, clear all stored DTCs
measurement when using the ‘Diagnosis Menu’ tab and
another value was retest
expected Check and install new cooling fan as
Harness failure - required
Engine control module
cooling fan circuits
Cooling fan failure

P115F- Electronic Control Module The engine control Refer to the electrical circuit diagrams
12 Cooling Fan Circuit - module has detected a and check the engine control module
Circuit short to battery vehicle power cooling fan circuit for short circuit to
measurement for a power. Repair harness as required.
period longer than Using the Jaguar Land Rover approved
expected or has diagnostic system, clear all stored DTCs
detected a vehicle using the ‘Diagnosis Menu’ tab and
power measurement retest
when another value
was expected
Harness failure -
Engine control module
cooling fan circuits

P115F- Electronic Control Module The engine control Refer to the electrical circuit diagrams
13 Cooling Fan Circuit - module has and check the engine control module
Circuit open determined an open cooling fan circuit for open circuit.
circuit via lack of bias Repair harness as required. Using the
voltage, low current Jaguar Land Rover approved diagnostic
flow, no change in the system, clear all stored DTCs using the
state of an input in ‘Diagnosis Menu’ tab and retest
response to an output Check and install new cooling fan as
Harness failure - required
Engine control module
cooling fan circuits
Cooling fan failure

P115F- Electronic Control Module Engine control module Refer to the electrical circuit diagrams
19 Cooling Fan Circuit - cooling fan circuit and check the engine control module
Circuit current above short circuit to ground cooling fan circuit for short circuit to
threshold Engine control module ground. Repair harness as required.
cooling fan failure or Using the Jaguar Land Rover approved
obstructed diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check engine control module cooling
fan for obstruction. Check and install
new engine control module cooling fan
as required

P120F- Fuel Pressure Regulator Fuel pressure regulator Using the Jaguar Land Rover approved
00 Excessive Variation - No signal circuit short diagnostic system, check for fuel pump
sub type information circuit to ground, short related DTCs
circuit to power, open Refer to the electrical circuit diagrams
circuit and check the fuel pressure regulator
Fuel pressure regulator signal circuit for short circuit to ground,
VREF circuit high short circuit to power, open circuit.
resistance Repair wiring harness as required,
Fuel pressure regulator Using the Jaguar Land Rover approved
failure diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest system
Refer to the electrical circuit diagrams
and check the fuel pressure regulator
VREF circuit for high resistance. Repair
wiring harness as required, Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest system
Check and install new Fuel pressure
regulator as required

P1247- Turbocharger Boost The boosting system is If this DTC is logged with P00BE-00,
00 Pressure Low - No sub unable to build/control suspect boost air recirculation solenoid
type information the boost pressure in stuck open in bi-turbo mode
the air induction If this DTC is logged with P00BC-00,
system suspect boost air solenoid stuck closed
Other related DTCs in bi-turbo mode
Fuel injection related If this DTC is logged with P0235-94,
DTCs P00BD-07, P22D2-77 & P22CF-71
Exhaust system suspect turbine intake solenoid stuck
leakage open
Pre turbocharger Check the vacuum system, Charge air
Excessive oil in the air shut-off valve and Turbine intake shut-
induction system off valve operation. Refer to section
Air induction system 303-04B or 303-04D and perform
leakage pinpoint test A Vacuum Control System
Charge air pressure Tests
sensor blocked If this DTC is logged with P006A-00,
Charge air shut-off P0402-00 & P00BF-07 suspect air
valve intake system, boost air system high
Turbine intake shut- pressure boost air leak on bank 1
off valve If this DTC is logged with P006A-00
Turbocharger system suspect air intake system, boost air
/vanes mechanical system high pressure boost air leak in
integrity bi-turbo mode on bank 2
If this DTC is logged with P00BE-07 &
P00BD-07 suspect variable geometry
turbocharger compressor wheel seized
If this DTC is logged with P0235-94,
P00BD-07, P22D2-77 & P22CF-71
suspect Air intake system, low pressure
intake blocked or restricted
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Turbocharger

P1334- EGR Throttle Position Exhaust gas Refer to the electrical circuit diagrams
00 Sensor recirculation throttle and check exhaust gas recirculation
Minimum/Maximum Stop position sensor circuit throttle position sensor circuit for short
Performance - No sub type short circuit to ground, circuit to ground, short circuit to power,
information short circuit to power, high resistance, open circuit. Repair
high resistance, open harness as required. Using the Jaguar
circuit Land Rover approved diagnostic
Exhaust gas system, clear all stored DTCs using the
recirculation throttle ‘Diagnosis Menu’ tab and retest
position sensor failure Check and install new exhaust gas
Engine control module recirculation throttle position sensor as
failure required
Check and install new engine control
module as required

P151B- Idle Speed Control - RPM Indicated torque at idle Using the Jaguar Land Rover approved
00 Lower Than Expected - No < minimum diagnostic system, check for additional
sub type information DTCs and refer to the relevant DTC
index. Check engine oil level. Carry out
cylinder compression tests. Check for
mechanical failure of engine

P151C- Idle Speed Control - RPM Indicated torque at idle Using the Jaguar Land Rover approved
00 Higher Than Expected - > maximum diagnostic system, check for additional
No sub type information DTCs and refer to the relevant DTC
index. Check engine oil level. Carry out
cylinder compression tests. Check for
mechanical failure of engine

P1551- Cylinder 1 Injector Circuit This DTC is set when Refer to the electrical circuit diagrams
32 Range/Performance - the engine control and check the injector control circuits
Signal low time < module detects that the for intermittent failures, open circuits,
minimum injector signal low short circuit to power, short circuit to
time is less than the ground, short circuit to other circuits.
minimum value Repair harness as required. Using the
Injector control circuit Jaguar Land Rover approved diagnostic
failure system, clear all stored DTCs using the
Injector failure ‘Diagnosis Menu’ tab and retest
Engine control module Refer to the workshop manual and
failure check the injector is to specification and
has been installed correctly. Check and
install new injector as required
Check and install new engine control
module as required

P1551- Cylinder 1 Injector Circuit This DTC is set when Refer to the electrical circuit diagrams
35 Range/Performance - the engine control and check the injector control circuits
Signal high time > module detects that the for intermittent failures, open circuits,
maximum injector signal high short circuit to power, short circuit to
time is greater than the ground, short circuit to other circuits.
maximum value Repair harness as required. Using the
Injector control circuit Jaguar Land Rover approved diagnostic
failure system, clear all stored DTCs using the
Injector failure ‘Diagnosis Menu’ tab and retest
Engine control module Refer to the workshop manual and
failure check the injector is to specification and
has been installed correctly. Check and
install new injector as required
Check and install new engine control
module as required

P1552- Cylinder 2 Injector Circuit This DTC is set when Refer to the electrical circuit diagrams
32 Range/Performance - the engine control and check fuel injector control circuit
Signal low time < module detects that the for short circuit to ground
minimum injector signal low Refer to the electrical circuit diagrams
time is less than the and check fuel injector control circuit
minimum value for short to each other
Harness failure - fuel
injector control circuit
short circuit to ground
Harness failure - fuel
injector control circuit
short to each other

P1552- Cylinder 2 Injector Circuit This DTC is set when Refer to the electrical circuit diagrams
35 Range/Performance - the engine control and check fuel injector control circuit
Signal high time > module detects that the for short circuit to power
maximum injector signal high Refer to the electrical circuit diagrams
time is greater than the and check fuel injector control circuit
maximum value for short to each other
Harness failure - fuel
injector control circuit
short circuit to power
Harness failure - fuel
injector control circuit
short to each other

P1553- Cylinder 3 Injector Circuit This DTC is set when Refer to the electrical circuit diagrams
32 Range/Performance - the engine control and check fuel injector control circuit
Signal low time < module detects that the for short circuit to ground
minimum injector signal low Refer to the electrical circuit diagrams
time is less than the and check fuel injector control circuit
minimum value for short to each other
Harness failure - fuel
injector control circuit
short circuit to ground
Harness failure - fuel
injector control circuit
short to each other

P1553- Cylinder 3 Injector Circuit This DTC is set when Refer to the electrical circuit diagrams
35 Range/Performance - the engine control and check fuel injector control circuit
Signal high time > module detects that the for short circuit to power
maximum injector signal high Refer to the electrical circuit diagrams
time is greater than the and check fuel injector control circuit
maximum value for short to each other
Harness failure - fuel
injector control circuit
short circuit to power
Harness failure - fuel
injector control circuit
short to each other

P1554- Cylinder 4 Injector Circuit This DTC is set when Refer to the electrical circuit diagrams
32 Range/Performance - the engine control and check fuel injector control circuit
Signal low time < module detects that the for short circuit to ground
minimum injector signal low Refer to the electrical circuit diagrams
time is less than the and check fuel injector control circuit
minimum value for short to each other
Harness failure - fuel
injector control circuit
short circuit to ground
Harness failure - fuel
injector control circuit
short to each other

P1554- Cylinder 4 Injector Circuit This DTC is set when Refer to the electrical circuit diagrams
35 Range/Performance - the engine control and check fuel injector control circuit
Signal high time > module detects that the for short circuit to power
maximum injector signal high Refer to the electrical circuit diagrams
time is greater than the and check fuel injector control circuit
maximum value for short to each other
Harness failure - fuel
injector control circuit
short circuit to power
Harness failure - fuel
injector control circuit
short to each other

P1555- Cylinder 5 Injector Circuit This DTC is set when Refer to the electrical circuit diagrams
32 Range/Performance - the engine control and check fuel injector control circuit
Signal low time < module detects that the for short circuit to ground
minimum injector signal low Refer to the electrical circuit diagrams
time is less than the and check fuel injector control circuit
minimum value for short to each other
Harness failure - fuel
injector control circuit
short circuit to ground
Harness failure - fuel
injector control circuit
short to each other

P1555- Cylinder 5 Injector Circuit This DTC is set when Refer to the electrical circuit diagrams
35 Range/Performance - the engine control and check fuel injector control circuit
Signal high time > module detects that the for short circuit to power
maximum injector signal high Refer to the electrical circuit diagrams
time is greater than the and check fuel injector control circuit
maximum value for short to each other
Harness failure - fuel
injector control circuit
short circuit to power
Harness failure - fuel
injector control circuit
short to each other

P1556- Cylinder 6 Injector Circuit This DTC is set when Refer to the electrical circuit diagrams
32 Range/Performance - the engine control and check fuel injector control circuit
Signal low time < module detects that the for short circuit to ground
minimum injector signal low Refer to the electrical circuit diagrams
time is less than the and check fuel injector control circuit
minimum value for short to each other
Harness failure - fuel
injector control circuit
short circuit to ground
Harness failure - fuel
injector control circuit
short to each other

P1556- Cylinder 6 Injector Circuit This DTC is set when Refer to the electrical circuit diagrams
35 Range/Performance - the engine control and check fuel injector control circuit
Signal high time > module detects that the for short circuit to power
maximum injector signal high Refer to the electrical circuit diagrams
time is greater than the and check fuel injector control circuit
maximum value for short to each other
Harness failure - fuel
injector control circuit
short circuit to power
Harness failure - fuel
injector control circuit
short to each other

P1575- Pedal Position Out Of Self Brake pedal switch - Refer to the electrical circuit diagrams
00 Test Range - No sub type Circuit Brake_SW_2 - and check brake pedal switch - Circuit
information Short circuit to power Brake_SW_2 - For short circuit to
Brake pedal switch - power
Circuit Brake_SW_2 - Refer to the electrical circuit diagrams
Open circuit and check brake pedal switch - Circuit
Brake switch failure Brake_SW_2 - For open circuit
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Drive the vehicle at greater than 11mph
(17kph) with a throttle pedal greater
than 10% for greater than 45 seconds.
Press the brake pedal, using maximum
travel for greater than 45 seconds, with
the vehicle stationary, press the brake
pedal using maximum travel for greater
than 1 second
Check and install new brake switch as
required

P1575- Pedal Position Out Of Self Brake pedal switch - Refer to the electrical circuit diagrams
62 Test Range - Signal Circuit Brake_SW_2 - and check brake pedal switch - Circuit
compare failure Short circuit to power Brake_SW_2 - For short circuit to
Brake pedal switch - power
Circuit Brake_SW_2 - Refer to the electrical circuit diagrams
Open circuit and check brake pedal switch - Circuit
Brake switch failure Brake_SW_2 - For open circuit
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Drive the vehicle at greater than 11mph
(17kph) with a throttle pedal greater
than 10% for greater than 45 seconds.
Press the brake pedal, using maximum
travel for greater than 45 seconds, with
the vehicle stationary, press the brake
pedal using maximum travel for greater
than 1 second
Check and install new brake switch as
required

P1592- Vehicle Data Recorder NOTE: NOTE:


42 Data Available - General
memory failure Calibration error, data If the DTC persists following a successful
corruption during write to software download, it should be ignored
non volatile memory (battery
disconnect during control Using the Jaguar Land Rover approved
module write sequence), diagnostic equipment, check and install
control module internal latest relevant level of software to the
failure powertrain control module
Using the Jaguar Land Rover approved
Powertrain control diagnostic equipment, clear the DTCs
module software and retest
calibration error
Corrupt powertrain
control module
software download

P1592- Vehicle Data Recorder NOTE: NOTE:


44 Data Available - Data
memory failure Calibration error, data If the DTC persists following a successful
corruption during write to software download, it should be ignored
non volatile memory (battery
disconnect during control Using the Jaguar Land Rover approved
module write sequence), diagnostic equipment, check and install
control module internal latest relevant level of software to the
failure powertrain control module
Using the Jaguar Land Rover approved
Powertrain control diagnostic equipment, clear the DTCs
module software and retest
calibration error
Corrupt powertrain
control module
software download

P1592- Vehicle Data Recorder NOTE: NOTE:


46 Data Available -
Calibration /parameter Calibration error, data If the DTC persists following a successful
memory failure corruption during write to software download, it should be ignored
non volatile memory (battery
disconnect during control Using the Jaguar Land Rover approved
module write sequence), diagnostic equipment, check and install
control module internal latest relevant level of software to the
failure powertrain control module
Using the Jaguar Land Rover approved
Powertrain control diagnostic equipment, clear the DTCs
module software and retest
calibration error
Corrupt powertrain
control module
software download

P1592- Vehicle Data Recorder NOTE: NOTE:


81 Data Available - Invalid
serial data received Calibration error, data If the DTC persists following a successful
corruption during write to software download, it should be ignored
non volatile memory (battery
disconnect during control Using the Jaguar Land Rover approved
module write sequence), diagnostic equipment, check and install
control module internal latest relevant level of software to the
failure powertrain control module
Using the Jaguar Land Rover approved
Powertrain control diagnostic equipment, clear the DTCs
module software and retest
calibration error
Corrupt powertrain
control module
software download

P1627- Module Supply Voltage The engine control Refer to the workshop manual and the
16 Out Of Range - Circuit module measured a battery care manual, inspect the vehicle
voltage below threshold voltage below a battery and ensure it is fully charged and
specified range but not serviceable before performing further
necessarily a short tests
circuit to ground Check the vehicle charging system
Vehicle battery failure performance to ensure the voltage
Charging system regulation is correct
failure Using the Jaguar Land Rover approved
Engine control module diagnostic system, check datalogger
power or ground signals, Control module voltage
supply (0xF442). This DTC is set when the
Engine junction box engine control module supply voltage is
failure below the threshold value. Refer to the
Power distribution electrical circuit diagrams and check the
failure four engine control module power
Engine control module ground circuits for high resistance or
failure open circuits
Check the switched power supply feeds
to the engine control module which
come from the engine junction box
though the engine management system
relay. Repair harness as required. Using
the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new engine control
module as required

P1627- Module Supply Voltage The engine control Refer to the workshop manual and the
17 Out Of Range - Circuit module measured a battery care manual, inspect the vehicle
voltage above threshold voltage above a battery and ensure it is fully charged and
specified range but not serviceable before performing further
necessarily a short tests
circuit to power Check the vehicle charging system
Vehicle battery failure performance to ensure the voltage
Charging system regulation is correct
failure Using the Jaguar Land Rover approved
Engine control module diagnostic system, check datalogger
power or ground signals, Control module voltage
supply (0xF442). This DTC is set when the
Engine junction box engine control module supply voltage is
failure greater than the threshold value. Refer
Power distribution to the electrical circuit diagrams and
failure check the four engine control module
power ground circuits for high
resistance or open circuits
Check the switched power supply feeds
to the engine control module which
come from the engine junction box
though the engine management system
relay. Repair harness as required. Using
the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest

P162F- Starter Motor Disabled - Vehicle battery failure Refer to the workshop manual and the
00 Engine Crank Time Too Other starting related battery care manual, inspect the vehicle
Long - No sub type failures battery and ensure it is fully charged and
information serviceable before performing further
tests
Using the Jaguar Land Rover approved
diagnostic system, check the engine
control module, for related DTCs and
refer to the relevant DTC index

P1631- Main Relay (power hold) - Vehicle battery This DTC is set when the engine
00 No sub type information disconnected before management system high current relay
engine management contacts open early - Indicating a power
system relay has hold failure. Check the vehicle battery
powered down has not been disconnected before the
Relay control circuit engine management system relay has
failure powered down. Check the operation of
Engine management the engine management system high
system high current current relay
relay failure Refer to the electrical circuit diagrams
Central junction box and check the engine management
failure system high current relay supply and
control circuits for open circuits, high
resistance, short circuit to ground, short
circuit to power, short circuit to other
circuits. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new relay as required
Check and install new central junction
box as required

P1631- Main Relay (power hold) - Engine management This DTC is set when the engine
73 Actuator stuck closed system high current management system high current relay
relay failure contacts are detected stuck closed by the
Relay control circuit engine control module. Check the
failure operation of the engine management
system high current relay. Refer to the
electrical circuit diagrams and check the
engine management system high current
relay supply and control circuits for
open circuits, high resistance, short
circuit to ground, short circuit to power,
short circuit to other circuits. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new relay as required

P165D- Grill Shutter "A" Control Grill shutter actuator Refer to the electrical circuit diagrams
01 Circuit - General electrical supply voltage falls and check the grill shutter actuator
failure outside the specified circuits for short circuit to ground, short
range circuit to power, open circuit, high
Grill shutter actuator resistance. Repair harness as required
internal circuit failure Using the Jaguar Land Rover approved
diagnostic system, operate the grill
shutter through the full operating range
and check that the DTC does not reset
Check and install new grill shutter
actuator as required

P165D- Grill Shutter "A" Control Grill shutter "A" Check all vanes within the grill shutter
07 Circuit - Mechanical actuator has become are connected to the grill shutter
failures disconnected from the actuator. Repair as required. Using the
grill shutter Jaguar Land Rover approved diagnostic
Linkage between the system, clear all stored DTCs using the
grill shutter "A" ‘Diagnosis Menu’ tab and retest
actuator and grill Using the Jaguar Land Rover approved
shutter has failed diagnostic system, operate the grill
shutter through the full operating range
and check that the DTC does not reset
Check and install new grill shutter as
required

P165D- Grill Shutter "A" Control Grill shutter "A" Refer to the electrical circuit diagrams
13 Circuit - Circuit open control circuit - Open and check the grill shutter actuator
circuit control circuit for open circuit. Repair
Grill shutter actuator harness as required
internal circuit failure Check and install new grill shutter
actuator as required

P165D- Grill Shutter "A" Control The grill shutter Check the grill shutter for damage,
4B Circuit - Over temperature actuator internal obstructions and blockages. Repair as
circuits are overheated required. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Using the Jaguar Land Rover approved
diagnostic system, operate the grill
shutter through the full operating range
and check that the DTC does not reset
Check and install new grill shutter
actuator as required

P165D- Grill Shutter "A" Control The engine control Refer to the electrical circuit diagrams
87 Circuit - Missing message module has not and check the grill shutter actuator
received the expected control circuit for open circuit, high
signal from the grill resistance. Repair harness as required.
shutter "A" actuator Using the Jaguar Land Rover approved
Grill shutter "A" diagnostic system, clear all stored DTCs
control circuit - Open using the ‘Diagnosis Menu’ tab and
circuit retest
Grill shutter actuator Check and install new grill shutter
internal circuit failure actuator as required

P165D- Grill Shutter "A" Control Grill shutter damaged, Check the grill shutter for damage,
97 Circuit - Component or obstructed or blocked obstructions and blockages. Repair as
system operation Grill shutter actuator required. Using the Jaguar Land Rover
obstructed or blocked has failed all approved diagnostic system, clear all
calibration attempts stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Using the Jaguar Land Rover approved
diagnostic system, operate the grill
shutter through the full operating range
and check that the DTC does not reset
Check and install new grill shutter
actuator as required

P1695- CAN Link Injection Pump The engine control Check engine control module for DTCs
00 Control Module/Engine module internal and refer to the relevant DTC index.
Control Module - No sub powerstage is Using the Jaguar Land Rover approved
type information overheated diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check the engine control module is
sufficiently able to be cooled

P1703- Brake Switch Out Of Self Brake switch circuit, Refer to the electrical circuit diagrams
00 Test Range - No sub type short circuit to ground, and check the brake switch for short to
information short circuit to power, ground, short circuit to power, high
high resistance, open resistance, open circuit. Repair wiring
circuit harness as required. Using the Jaguar
Brake switch incorrect Land Rover approved diagnostic
adjustment system, clear all stored DTCs using the
Brake switch internal ‘Diagnosis Menu’ tab and retest
failure Check and adjust brake switch as
required
Check and install new brake switch as
required

P1712- Transmission Torque Unintended torque Check transmission control module for
00 Reduction Request Signal - request signal sent related DTCs and refer to relevant DTC
No sub type information over CAN from index, Using the Jaguar Land Rover
transmission control approved diagnostic system, clear all
module to engine stored DTCs using the ‘Diagnosis
control module. The Menu’ tab and retest
engine control module
recognizes it is
unintended and applies
a torque limit and sets
the DTC

P1719- Engine Torque Signal - Working limitation Check engine control module for related
68 Event information information DTCs and refer to relevant DTC index
The DTC sets as a Refer to the workshop manual and
result of an engine check the cooling system is functioning
torque limitation correctly
caused by an engine
overheat situation

P2002- Diesel Particulate Filter Diesel particulate filter Using the Jaguar Land Rover approved
68 Efficiency Below regeneration disabled diagnostic system, check for related
Threshold (Bank 1) - Event by other DTCs logged DTCs and refer to the relevant DTC
information index. Carry out a diesel particulate
filter regeneration

P2031- Exhaust Gas Temperature Exhaust gas Refer to the electrical circuit diagrams
00 Sensor Circuit Bank 1 temperature sensor and check exhaust gas temperature
Sensor 2 - No sub type post catalytic sensor post catalytic converter circuit
information converter short circuit for short circuit to ground
to ground Check and install new exhaust gas
Exhaust gas temperature sensor post catalytic
temperature sensor converter as required
post catalytic
converter failure

P2032- Exhaust Gas Temperature Harness failure - Using the Jaguar Land Rover approved
00 Sensor Circuit Low Bank 1 Particulate filter inlet diagnostic system, check datalogger
Sensor 2 - No sub type exhaust gas signals, Exhaust Gas Temperature Bank
information temperature sensor 1 Sensor 2 Voltage (0x03C4), Exhaust
Particulate filter inlet Gas Temperature Bank 1 Sensor 2
exhaust gas (0x03F5). This DTC is set if the
temperature sensor particulate filter inlet exhaust gas
failure temperature sensor fails a diagnostic
check due to the circuit voltage being
less than the expected value. Refer to
the electrical circuit diagrams and check
the signal circuit for open circuit, short
circuit to power, short circuit to ground,
high resistance. Check the ground
circuit for open circuit, high resistance,
short circuit to power. Repair harness as
required
Check and install new exhaust gas
temperature sensor as required

P2033- Exhaust Gas Temperature Harness failure - Using the Jaguar Land Rover approved
00 Sensor Circuit High Bank Particulate filter inlet diagnostic system, check datalogger
1 Sensor 2 - No sub type exhaust gas signals, Exhaust Gas Temperature Bank
information temperature sensor 1 Sensor 2 Voltage (0x03C4), Exhaust
Particulate filter inlet Gas Temperature Bank 1 Sensor 2
exhaust gas (0x03F5). This DTC is set if the
temperature sensor particulate filter inlet exhaust gas
failure temperature sensor fails a diagnostic
check due to the circuit voltage being
greater than the expected value. Refer to
the electrical circuit diagrams and check
the signal circuit for open circuit, short
circuit to power, short circuit to ground,
high resistance. Check the ground
circuit for open circuit, high resistance,
short circuit to power. Repair harness as
required
Check and install new exhaust gas
temperature sensor as required

P2034- Exhaust Gas Temperature Exhaust gas Refer to the electrical circuit diagrams
00 Sensor Circuit Bank 2 temperature sensor pre and check exhaust gas temperature
Sensor 2 - No sub type DPF short circuit to sensor pre DPF circuit for short circuit
information ground, stuck in range to ground, stuck in range
Exhaust gas Using the Jaguar Land Rover approved
temperature sensor pre diagnostic system, clear all stored DTCs
DPF failure using the ‘Diagnosis Menu’ tab and
retest
Check and install new exhaust gas
temperature sensor pre DPF as required
P2036- Exhaust Gas Temperature Exhaust gas Refer to the electrical circuit diagrams
00 Sensor Circuit High Bank temperature sensor pre and check exhaust gas temperature
2 Sensor 2 - No sub type DPF short circuit to sensor pre DPF circuit for short circuit
information power, open circuit, to power, open circuit, high resistance
high resistance Inspect connectors for signs of water
Connector is ingress and pins for damage and/or
disconnected, corrosion
connector pin is Using the Jaguar Land Rover approved
backed out, connector diagnostic system, clear all stored DTCs
pin corrosion using the ‘Diagnosis Menu’ tab and
Exhaust gas retest
temperature sensor pre Check and install new exhaust gas
DPF failure temperature sensor pre DPF as required

P2080- Exhaust Gas Temperature Exhaust gas Using the Jaguar Land Rover approved
00 Sensor Circuit temperature sensor diagnostic system, check datalogger
Range/Performance Bank 1 post turbocharger signals, Exhaust Gas Temperature Bank
Sensor 1 - No sub type overheating 1 Sensor 1 Voltage (0x03BF), Exhaust
information Exhaust gas Gas Temperature Bank 2 Sensor 1
temperature sensor (0x03F7)
post turbocharger Refer to the electrical circuit diagrams
circuit short circuit to and check exhaust gas temperature
ground sensor post turbocharger circuit for short
circuit to ground
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new exhaust gas
temperature sensor post turbocharger -
bank 2, sensor 1 as required

P2082- Exhaust Gas Temperature Exhaust gas Refer to the electrical circuit diagrams
00 Sensor Circuit temperature sensor and check exhaust gas temperature
Range/Performance Bank 2 post turbocharger sensor post turbocharger circuit for short
Sensor 1 - No sub type short circuit short circuit to ground, open circuit, high
information circuit to ground, open resistance
circuit, high resistance Clear the DTC and retest
Exhaust gas Check and install new exhaust gas
temperature sensor temperature sensor post turbocharger as
post turbocharger required
failure

P2084- Exhaust Gas Temperature Exhaust gas Refer to the electrical circuit diagrams
00 Sensor Circuit temperature sensor and check exhaust gas temperature
Range/Performance Bank 1 post catalytic sensor post catalytic converter circuit
Sensor 2 - No sub type converter overheating for short circuit to ground
information Exhaust gas Clear the DTC and retest
temperature sensor Check and install new exhaust gas
post catalytic temperature sensor post catalytic
converter circuit, short converter as required
circuit to ground
Exhaust gas
temperature sensor
post catalytic
converter failure
P2086- Exhaust Gas Temperature The engine control Using the Jaguar Land Rover approved
00 Sensor Circuit module has measured diagnostic system, clear all stored DTCs
Range/Performance Bank 2 an intermittent exhaust using the ‘Diagnosis Menu’ tab and
Sensor 2 - No sub type gas temperature retest
information greater than expected, Refer to the electrical circuit diagrams
possibly during a DPF and check exhaust gas temperature
regeneration cycle sensor pre DPF circuit for short circuit
Exhaust gas to ground, open circuit, high resistance
temperature sensor pre Inspect connectors for signs of water
DPF short circuit to ingress and pins for damage and/or
ground, open circuit, corrosion
high resistance Using the Jaguar Land Rover approved
Connector is diagnostic system, clear all stored DTCs
disconnected, using the ‘Diagnosis Menu’ tab and
connector pin is retest
backed out, connector Check and install new exhaust gas
pin corrosion temperature sensor pre DPF as required
Exhaust gas
temperature sensor pre
DPF failure

P2121- Throttle/Pedal Position Harness failure - Using the Jaguar Land Rover approved
1F Sensor/Switch D Circuit Accelerator pedal diagnostic system, check datalogger
Range/Performance - position sensor circuit signals, Accelerator Pedal Position D
Circuit intermittent Accelerator pedal (0xF449), Pedal Position Sensor
position sensor failure Voltage - Sensor 1 (0x0914). The
accelerator pedal position sensor
consists of two potentiometer circuits
feeding independent pedal demand
signals to the engine control module.
This DTC is set when the engine control
module detects noise on the pedal
demand 1 signal circuit. Refer to the
electrical circuit diagrams and check the
reference voltage and ground
connections to the accelerator pedal
position sensor. Check signal circuits
for high resistance, open circuit, short
circuit to power, short circuit to ground.
Check all accelerator pedal position
sensor circuits for intermittent failures.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new accelerator pedal
position sensor as required

P2122- Throttle/Pedal Position Harness failure - Using the Jaguar Land Rover approved
00 Sensor/Switch D Circuit Accelerator pedal diagnostic system, check datalogger
Low - No sub type position sensor circuit signals, Accelerator Pedal Position D
information Accelerator pedal (0xF449), Pedal Position Sensor
position sensor failure Voltage - Sensor 1 (0x0914). The
Accelerator Pedal Position sensor
consists of two potentiometer circuits
feeding independent pedal demand
signals to the engine control module.
This DTC is set when the engine control
module detects the pedal demand 1
signal range is low. Refer to the
electrical circuit diagrams and check the
reference voltage and ground
connections to the accelerator pedal
position sensor. Check signal circuits
for high resistance, open circuit, short
circuit to power, short circuit to ground.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new accelerator pedal
position sensor as required

P2123- Throttle/Pedal Position Harness failure - Using the Jaguar Land Rover approved
00 Sensor/Switch D Circuit Accelerator pedal diagnostic system, check datalogger
High - No sub type position sensor circuit signals, Accelerator Pedal Position D
information Accelerator pedal (0xF449), Pedal Position Sensor
position sensor failure Voltage - Sensor 1 (0x0914). The
Accelerator Pedal Position sensor
consists of two potentiometer circuits
feeding independent pedal demand
signals to the engine control module.
This DTC is set when the engine control
module detects the pedal demand 1
signal range is high. Refer to the
electrical circuit diagrams and check the
reference voltage and ground
connections to the accelerator pedal
position sensor. Check signal circuits
for high resistance, open circuit, short
circuit to power, short circuit to ground.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new accelerator pedal
position sensor as required

P2126- Throttle/Pedal Position Harness failure - Using the Jaguar Land Rover approved
1F Sensor/Switch E Circuit Accelerator pedal diagnostic system, check datalogger
Range/Performance - position sensor circuit signals, Accelerator Pedal Position E
Circuit intermittent Accelerator pedal (0xF44A), Pedal Position Sensor
position sensor failure Voltage - Sensor 2 (0x0915). The
Accelerator Pedal Position sensor
consists of two potentiometer circuits
feeding independent pedal demand
signals to the engine control module.
This DTC is set when the engine control
module detects noise on the pedal
demand 2 signal circuit. Refer to the
electrical circuit diagrams and check the
reference voltage and ground
connections to the accelerator pedal
position sensor. Check signal circuits
for high resistance, open circuit, short
circuit to power, short circuit to ground.
Check all accelerator pedal position
sensor circuits for intermittent failures.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new accelerator pedal
position sensor as required

P2127- Throttle/Pedal Position Harness failure - Using the Jaguar Land Rover approved
00 Sensor/Switch E Circuit Accelerator pedal diagnostic system, check datalogger
Low - No sub type position sensor circuit signals, Accelerator Pedal Position E
information Accelerator pedal (0xF44A), Pedal Position Sensor
position sensor failure Voltage - Sensor 2 (0x0915). The
Accelerator Pedal Position sensor
consists of two potentiometer circuits
feeding independent pedal demand
signals to the engine control module.
This DTC is set when the engine control
module detects the pedal demand 2
signal range is low. Refer to the
electrical circuit diagrams and check the
reference voltage and ground
connections to the accelerator pedal
position sensor. Check signal circuits
for high resistance, open circuits, short
circuit to power, short circuit to ground.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new accelerator pedal
position sensor as required

P2128- Throttle/Pedal Position Harness failure - Using the Jaguar Land Rover approved
00 Sensor/Switch E Circuit Accelerator pedal diagnostic system, check datalogger
High - No sub type position sensor circuit signals, Accelerator Pedal Position E
information Accelerator pedal (0xF44A), Pedal Position Sensor
position sensor failure Voltage - Sensor 2 (0x0915). The
Accelerator Pedal Position sensor
consists of two potentiometer circuits
feeding independent pedal demand
signals to the engine control module.
This DTC is set when the engine control
module detects the pedal demand 2
signal range is high. Refer to the
electrical circuit diagrams and check the
reference voltage and ground
connections to the accelerator pedal
position sensor. Check signal circuits
for high resistance, open circuits, short
circuit to power, short circuit to ground.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new accelerator pedal
position sensor as required

P2138- Throttle/Pedal Position Accelerator pedal Refer to the electrical circuit diagrams
00 Sensor/Switch D /E position sensor circuit and check accelerator pedal position
Voltage Correlation - No short circuit to ground, sensor 1 circuit for short circuit to
sub type information short circuit to power, ground, short circuit to power, open
open circuit circuit. Refer to the electrical circuit
Accelerator pedal diagrams and check accelerator pedal
position sensor failure position sensor 2 circuit for short circuit
to ground, short circuit to power, open
circuit. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new accelerator pedal
position sensor as required

P2138- Throttle/Pedal Position Accelerator pedal Refer to the electrical circuit diagrams
64 Sensor/Switch D /E position sensor circuit and check accelerator pedal position
Voltage Correlation - short circuit to ground, sensor 1 circuit for short circuit to
Signal plausibility failure short circuit to power, ground, short circuit to power, open
open circuit circuit. Refer to the electrical circuit
Accelerator pedal diagrams and check accelerator pedal
position sensor failure position sensor 2 circuit for short circuit
to ground, short circuit to power, open
circuit. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new accelerator pedal
position sensor as required

P2138- Throttle/Pedal Position Accelerator pedal Refer to the electrical circuit diagrams
67 Sensor/Switch D /E position sensor circuit and check accelerator pedal position
Voltage Correlation - short circuit to ground, sensor 1 circuit for short circuit to
Signal incorrect after event short circuit to power, ground, short circuit to power, open
open circuit circuit. Refer to the electrical circuit
Accelerator pedal diagrams and check accelerator pedal
position sensor failure position sensor 2 circuit for short circuit
to ground, short circuit to power, open
circuit. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new accelerator pedal
position sensor as required

P213E- Fuel Injection System Quantity shut-off of Check for fuel /injector related DTCs
01 Fault - Forced Engine the dual-mass and repair these first. Using the Jaguar
Shutdown - General flywheel Land Rover approved diagnostic
electrical failure system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest

P2141- Exhaust Gas Recirculation Harness failure - This DTC is set when the engine control
00 Throttle Control Circuit A Throttle motor control module detects a short circuit to ground
Low - No sub type circuit on the throttle motor control circuit.
information Throttle motor failure Refer to the electrical circuit diagrams
and check both the throttle plate
actuator control circuits for short circuit
to ground. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new throttle motor
control actuator as required

P2142- Exhaust Gas Recirculation Harness failure - This DTC is set when the engine control
00 Throttle Control Circuit A Throttle motor control module detects a short circuit to power
High - No sub type circuit on the throttle motor control circuit.
information Throttle motor failure Refer to the electrical circuit diagrams
and check both the Throttle Plate
Actuator control circuits for short circuit
to power. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Exhaust gas recirculation valve. Clear
the DTCs and retest
Check and install new throttle motor
control actuator as required

P2177- System Too Lean Off Idle Oxygen concentration Check for excess fuel at exhaust
00 - Bank 1 - No sub type implausibly high manifold, downpipe, heated oxygen
information Heated oxygen sensor sensor
circuit short circuit to Check for fuel /injector related DTCs
ground, short circuit to and repair these first. Using the Jaguar
power, high resistance, Land Rover approved diagnostic
open circuit system, clear all stored DTCs using the
Heated oxygen sensor ‘Diagnosis Menu’ tab and retest
failure Refer to the electrical circuit diagrams
and check heated oxygen sensor for
short circuit to ground, high resistance,
open circuit. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new heated oxygen
sensor as required

P2178- System Too Rich Off Idle - Oxygen concentration Check for air leaks at exhaust manifold,
00 Bank 1 - No sub type implausibly low downpipe, heated oxygen sensor
information Heated oxygen sensor Check for fuel /injector related DTCs
circuit short circuit to and repair these first. Using the Jaguar
ground, short circuit to Land Rover approved diagnostic
power, high resistance, system, clear all stored DTCs using the
open circuit ‘Diagnosis Menu’ tab and retest
Heated oxygen sensor Refer to the electrical circuit diagrams
failure and check heated oxygen sensor for
short circuit to ground, high resistance,
open circuit. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new heated oxygen
sensor as required

P2191- System Too Lean at Higher Oxygen concentration Check for excess fuel at exhaust
00 Load - Bank 1 - No sub implausibly high manifold, downpipe, heated oxygen
type information Heated oxygen sensor sensor
circuit short circuit to Check for fuel /injector related DTCs
ground, short circuit to and repair these first. Using the Jaguar
power, high resistance, Land Rover approved diagnostic
open circuit system, clear all stored DTCs using the
Heated oxygen sensor ‘Diagnosis Menu’ tab and retest
failure Refer to the electrical circuit diagrams
and check heated oxygen sensor for
short circuit to ground, high resistance,
open circuit. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new heated oxygen
sensor as required

P2192- System Too Rich at Higher Oxygen concentration Check for air leaks at exhaust manifold,
00 Load - Bank 1 - No sub implausibly low downpipe, heated oxygen sensor
type information Heated oxygen sensor Check for fuel /injector related DTCs
circuit short circuit to and repair these first. Using the Jaguar
ground, short circuit to Land Rover approved diagnostic
power, high resistance, system, clear all stored DTCs using the
open circuit ‘Diagnosis Menu’ tab and retest
Heated oxygen sensor Refer to the electrical circuit diagrams
failure and check heated oxygen sensor for
short circuit to ground, high resistance,
open circuit. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new heated oxygen
sensor as required
P2195- O2 Sensor Signal Air leak at exhaust Check for fuel /injector related DTCs
00 biased/Stuck Lean - Bank manifold, downpipe, and repair these first. Using the Jaguar
1, Sensor 1 - No sub type heated oxygen sensor Land Rover approved diagnostic
information bank 1 system, clear all stored DTCs using the
Heated oxygen sensor ‘Diagnosis Menu’ tab and retest
circuit short circuit to Check for air leaks at exhaust manifold,
ground, short circuit to downpipe, heated oxygen sensor
power, high resistance, Refer to the electrical circuit diagrams
open circuit and check heated oxygen sensor for
Heated oxygen sensor short circuit to ground, high resistance,
failure open circuit. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new heated oxygen
sensor as required

P2196- O2 Sensor Signal Fuel injection system Check for fuel /injector related DTCs
00 biased/Stuck Rich - Bank failure and repair these first. Using the Jaguar
1, Sensor 1 - No sub type Heated oxygen sensor Land Rover approved diagnostic
information circuit short circuit to system, clear all stored DTCs using the
ground, short circuit to ‘Diagnosis Menu’ tab and retest
power, high resistance, Refer to the electrical circuit diagrams
open circuit and check heated oxygen sensor for
Heated oxygen sensor short circuit to ground, high resistance,
failure open circuit. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new heated oxygen
sensor as required

P2226- Barometric Pressure Differential pressure Refer to the electrical circuit diagrams
62 Sensor A Circuit - Signal sensor circuit short and check differential pressure sensor
compare failure circuit to ground, short circuit for short circuit to ground, short
circuit to power, open circuit to power, open circuit, high
circuit, high resistance resistance
Differential pressure Check the engine control module is
sensor failure clean and dry
The engine control Check the engine control module is not
module has been sealed by any non approved covering
submersed in water or Using the Jaguar Land Rover approved
mud diagnostic system, clear all stored DTCs
The engine control using the ‘Diagnosis Menu’ tab and
module has been retest
sealed in a non Check and install new differential
approved covering pressure sensor as required
Differential pressure Check and install new engine control
sensor failure module as required
Engine control module
failure

P2228- Barometric Pressure Corrupt engine control Using the Jaguar Land Rover approved
00 Sensor A Circuit Low - No module software flash diagnostic system, re-configure the
sub type information Engine control module engine control module
power supply failure Refer to the electrical circuit diagrams
Engine control module and check engine control module power
ground supply failure supply circuits for open circuit. Repair
Engine control module harness as required. Using the Jaguar
failure Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Refer to the electrical circuit diagrams
and check engine control module
ground supply circuits for open circuit.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new engine control
module as required

P2229- Barometric Pressure Corrupt engine control Using the Jaguar Land Rover approved
00 Sensor A Circuit High - No module software flash diagnostic system, re-configure the
sub type information Engine control module engine control module
power supply failure Refer to the electrical circuit diagrams
Engine control module and check engine control module power
ground supply failure supply circuits for open circuit. Repair
Engine control module harness as required. Using the Jaguar
failure Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Refer to the electrical circuit diagrams
and check engine control module
ground supply circuits for open circuit.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new engine control
module as required

P2238- O2 Sensor Positive Current Heated oxygen sensor Refer to the electrical circuit diagrams
00 Control Circuit Low - positive current and check heated oxygen sensor for
Bank 1, Sensor 1 - No sub control circuit short short circuit to ground, high resistance,
type information circuit to ground, high open circuit. Repair harness as required.
resistance, open circuit Using the Jaguar Land Rover approved
Heated oxygen sensor diagnostic system, clear all stored DTCs
failure using the ‘Diagnosis Menu’ tab and
retest
Check and install new heated oxygen
sensor as required

P2245- O2 Sensor Reference Harness failure - This DTC is set if the engine control
00 Voltage Circuit Low - Heated oxygen sensor module detects the bank 1, heated
Bank 1, Sensor 1 - No sub circuit oxygen sensor 1 reference voltage is
type information Oxygen sensor failure lower than expected. Refer to the
electrical circuit diagrams and check the
heated oxygen sensor circuits for open
circuits, high resistance, short circuit to
ground. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new heated oxygen
sensor as required

P2246- O2 Sensor Reference Harness failure - This DTC is set if the engine control
00 Voltage Circuit High - Heated oxygen sensor module detects the bank 1, heated
Bank 1, Sensor 1 - No sub circuit oxygen sensor 1 reference voltage is
type information Oxygen sensor failure greater than expected. Refer to the
electrical circuit diagrams and check the
heated oxygen sensor circuits for open
circuits, high resistance, short circuit to
power. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new heated oxygen
sensor as required

P2261- Turbocharger/Supercharger The engine control This DTC is set when the engine control
73 Bypass Valve "A" - module has not module detects that the turbocharger
Mechanical - Actuator detected any motion, bypass valve is not operating
stuck closed upon commanding the Check the vacuum system, Charge air
operation of a motor, shut-off valve and Turbine intake shut-
solenoid or relay to off valve operation. Refer to section
open some piece of 303-04B or 303-04D and perform
equipment pinpoint test A Vacuum Control System
Boost air recirculation Tests
solenoid stuck shut
during transition from
mono turbo to bi-turbo
mode

P2263- Turbocharger/Supercharger The engine control Check induction system for leaks,
21 Boost System Performance module measured a blockages
- Signal amplitude < signal voltage below a Check boost air system for leaks,
minimum specified range but not blockages. Check for related DTCs
necessarily a short Refer to the electrical circuit diagrams
circuit to ground, gain and check manifold absolute pressure
low sensor circuit for short circuit to power,
Induction system air ground, open circuit. Repair harness as
leak or blockage required
Boost air system leak Check and install new manifold absolute
or blockage pressure sensor as required
Manifold absolute Check turbocharger rod connection and
pressure sensor circuit oil seals
short circuit to power, Check and install new variable
ground, open circuit geometry turbocharger actuator as
Manifold absolute required. Check install new
pressure sensor failure turbocharger as required
Variable geometry
turbocharger actuator
A sticking, failure
Turbocharger A
failure

P2263- Turbocharger/Supercharger Electrical Cause Prioritised Checks to Perform


22 Boost System Performance Yes Refer to the corresponding bulletins and
- Signal amplitude > Mechanical Cause SSMs which may be valid for the
maximum Yes specific customer complaint and carry
Prioritised List of out the recommendations as required
Possible Causes Check electronic throttle for sticking,
Electronic throttle excessive debris preventing blade
sticking, excessive movement
debris Using the Jaguar Land Rover approved
Variable geometry diagnostic system, perform routine -
turbocharger actuator Inline diagnostic unit 2 diagnostic test -
sticking, failure Turbocharger
Charge air system Follow Pinpoint Test A: Vacuum
failures Control System Tests - Twin Turbo
Incorrectly Variants Only. Refer to section 303-04B
installed hoses Fuel Charging and Controls -
Leakage Turbocharger
Blockage Using the Jaguar Land Rover approved
Variable diagnostic system, perform smoke
geometry checks on the following systems
turbocharger Charge air system
Turbocharger Vacuum system
pressure sensor Exhaust system
Vacuum system Air intake system
failures Check crankcase breather and oil
Engine mounts separator stub
Plug of the Refer to the electrical circuit diagrams
vacuum line and check manifold absolute pressure
Actuator - sensor circuit for short circuit to power,
Capsule vacuum ground, open circuit
engine system Check and install a new manifold
Crankcase breather absolute pressure sensor as required
and oil separator stub
Manifold absolute
pressure sensor circuit
short circuit to power,
ground, open circuit
Manifold absolute
pressure sensor failure

P2264- Water in Fuel Sensor Fuel supply This DTC is set if the engine control
00 Circuit - No sub type incorrect/contaminated module receives information indicating
information Harness failure - an implausible fuel level. Refer to the
Water in fuel sensor workshop manual and check the fuel
circuit system to ensure there is an adequate
Water in fuel sensor fuel level in the tank and the system is
failure not leaking fuel or suffering from air
Central junction box ingress. Check the fuel for
power distribution contamination by other fluids (petrol or
failure water etc)
Refer to the electrical wiring diagrams
and check the water in fuel sensor signal
circuit between the sensor and the
engine control module for high
resistance, open circuit, short circuit to
ground, short circuit to power,
intermittent failures. Repair harness as
required
Check and install new water in fuel
sensor
Refer to the electrical wiring diagrams
and check the water in fuel sensor
power supply from the central junction
box for high resistance, open circuit,
short circuit to ground. Check the water
in fuel sensor ground supply circuit for
high resistance, open circuit, short
circuit to power. Check the voltage
supply from the central junction box,
check and replace fuses as required.
Replace central junction box if there is
no voltage supply to the water in fuel
sensor

P2269- Water in Fuel Condition - Water in fuel Drain water from fuel filter housing.
68 Event information Water in fuel sensor Clear DTC and wait 30 seconds and re-
circuit short circuit to check DTC has cleared
power, open circuit Refer to the electrical circuit diagrams
Water in fuel sensor and check water in fuel sensor circuit
failure for short circuit to power, open circuit.
Repair harness as required
Check and install new water in fuel
sensor as required

P226B- Turbocharger/Supercharger Error path indicating Check for turbocharging related DTCs
00 Boost Pressure Too High - whether over boost and repair these first. Using the Jaguar
Mechanical - No sub type shut down is active or Land Rover approved diagnostic
information not system, clear all stored DTCs using the
This DTC is set when ‘Diagnosis Menu’ tab and retest
overboost shut down is Using the Jaguar Land Rover approved
active. This means that diagnostic system, perform routine -
the vehicle has lost Inline diagnostic unit 2 diagnostic test -
control of boost. The Turbocharger
engine is shut down as
a safety precaution.
The engine control
module checks for an
overboost by system
monitoring and also
monitors vehicle
acceleration, if in gear
and engine
acceleration at idle, if
in neutral

P228C- Fuel Pressure Regulator 1 Fuel pressure control Check fuel pressure control valve for
00 Exceeded Control Limits - valve, fuel leak from fuel leakage from the high pressure side
Pressure Too Low - No sub the high pressure side Check for fuel injector stuck open
type information Fuel injector stuck /leaking
open /leaking Check for blocked fuel filter
Blocked fuel filter Check for low pressure fuel pipe
Low pressure fuel pipe leakage from the fuel tank fuel pump
leaking from the fuel Using the Jaguar Land Rover approved
tank fuel pump diagnostic system, check datalogger
Fuel supply system signals, Fuel Rail Pressure Sensor
failure (0x0324), Fuel Rail Pressure (0xF423).
Harness failure - Fuel Check for related fuel system DTCs and
rail pressure sensor A refer to the relevant DTC index
circuit high resistance Refer to the electrical circuit diagrams
Fuel rail pressure and check fuel pump circuit for high
sensor A failure resistance. Check fuel rail pressure
Fuel lift pump failure sensor A circuit for high resistance
Check and install new fuel rail pressure
sensor A as required
Check and install new fuel lift pump as
required

P2297- O2 Sensor Out of Range Heated oxygen sensor Check for fuel /injector related DTCs
00 During Deceleration Bank circuit short circuit to and repair these first. Using the Jaguar
1, Sensor 1 - No sub type ground, short circuit to Land Rover approved diagnostic
information power, high resistance, system, clear all stored DTCs using the
open circuit ‘Diagnosis Menu’ tab and retest. Refer
Heated oxygen sensor to the electrical circuit diagrams and
failure check heated oxygen sensor for short
circuit to ground, high resistance, open
circuit. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new heated oxygen
sensor as required

P2299- Brake Pedal Brake pedal switch - Refer to the electrical circuit diagrams
68 Position/Accelerator Pedal Circuit Brake_SW_1 - and check brake pedal switch - Circuit
Position Incompatible - Short circuit to Brake_SW_1 - For short circuit to
Event information ground, open circuit ground, open circuit. Repair harness as
Brake pedal switch - required.
Circuit Brake_SW_2 - Refer to the electrical circuit diagrams
Short circuit to ground and check brake pedal switch - Circuit
Brake pedal switch Brake_SW_2 - For short circuit to
incorrect adjustment ground
Brake pedal switch Repair wiring harness as required, clear
failure DTC. Start the engine press the brake
Brake pedal pressed pedal, using maximum travel for greater
by driver at same time than 1 second taking care not to press
as accelerator pedal the accelerator pedal. Check the system
pressed is operating correctly and the DTC does
not return
Check and adjust brake switch as
required
Check and install new brake pedal
switch as required

P22C5- Turbocharger Compressor The engine control Refer to the electrical circuit diagrams
11 Outlet Valve Control module has detected a and check the turbocharger boost air
Circuit /Open - Circuit ground measurement solenoid circuit between the engine
short to ground for a period longer control module and the control valve for
than expected or has a short circuit to ground. Check power
detected a ground supply to the control valve. Repair
measurement when harness as required. Using the Jaguar
another value was Land Rover approved diagnostic
expected system, clear all stored DTCs using the
Harness failure - ‘Diagnosis Menu’ tab and retest
Turbocharger boost air
solenoid circuit short
circuit to ground

P22C5- Turbocharger Compressor The engine control Refer to the electrical circuit diagrams
12 Outlet Valve Control module has detected a and check the turbocharger boost air
Circuit /Open - Circuit vehicle power solenoid circuit between the engine
short to battery measurement for a control module and the control valve for
period longer than a short circuit to power. Check power
expected or has supply to the control valve. Repair
detected a vehicle harness as required. Using the Jaguar
power measurement Land Rover approved diagnostic
when another value system, clear all stored DTCs using the
was expected ‘Diagnosis Menu’ tab and retest
Harness failure - Check and install new turbocharger
Turbocharger boost air boost air solenoid as required
solenoid circuit short
circuit to power
Turbocharger boost air
solenoid failure

P22C5- Turbocharger Compressor The engine control Refer to the electrical circuit diagrams
13 Outlet Valve Control module has and check the turbocharger boost air
Circuit /Open - Circuit determined an open solenoid circuit between the engine
open circuit via lack of bias control module and the control valve for
voltage, low current open circuit. Check power supply to the
flow, no change in the control valve. Repair harness as
state of an input in required. Using the Jaguar Land Rover
response to an output approved diagnostic system, clear all
Harness failure - stored DTCs using the ‘Diagnosis
Turbocharger boost air Menu’ tab and retest
solenoid circuit open Check and install new turbocharger
circuit boost air solenoid as required
Turbocharger boost air
solenoid failure

P22C5- Turbocharger Compressor Harness failure - Refer to the electrical circuit diagrams
4B Outlet Valve Control Turbocharger boost air and check the turbocharger boost air
Circuit /Open - Over solenoid circuit open solenoid circuit between the engine
temperature circuit control module and the control valve for
Turbocharger boost air open circuit. Check power supply to the
solenoid failure control valve. Repair harness as
required. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Check and install new turbocharger
boost air solenoid as required. Check
and install new turbocharger boost air
solenoid as required
P22CF- Turbocharger Turbine Inlet Harness failure - Using the Jaguar Land Rover approved
00 Valve Control Circuit Turbine intake diagnostic system, check datalogger
/Open - No sub type solenoid circuit open signals, Turbo Shut Off Valve Opening
information circuit Position - Commanded (0x03F0). Refer
Turbine intake to the electrical circuit diagrams and
solenoid failure check the turbine intake solenoid circuit
between the engine control module and
the control valve for open circuit. Check
power supply to the control valve.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new turbine intake
solenoid as required

P22CF- Turbocharger Turbine Inlet The engine control Using the Jaguar Land Rover approved
16 Valve Control Circuit module measured a diagnostic system, check datalogger
/Open - Circuit voltage voltage below a signals, Turbo Shut Off Valve Opening
below threshold specified range but not Position - Commanded (0x03F0). Refer
necessarily a short to the electrical circuit diagrams and
circuit to ground check the turbine intake solenoid circuit
Harness failure - between the engine control module and
Turbine intake the control valve for a high resistance,
solenoid circuit failure intermittent open circuit, short circuit to
Turbine intake ground. Check power supply to the
solenoid failure control valve. Repair harness as
required. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Check and install new turbine intake
solenoid as required

P22CF- Turbocharger Turbine Inlet Harness failure - Using the Jaguar Land Rover approved
19 Valve Control Circuit Turbine intake diagnostic system, check datalogger
/Open - Circuit current solenoid circuit failure signals, Turbo Shut Off Valve Opening
above threshold Turbine intake Position - Commanded (0x03F0). Refer
solenoid failure to the electrical circuit diagrams and
check the turbine intake valve control
circuit for short circuit to ground. Check
power supply to the solenoid. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new turbine intake
solenoid as required

P22CF- Turbocharger Turbine Inlet Harness failure - Using the Jaguar Land Rover approved
1D Valve Control Circuit Turbine intake diagnostic system, check datalogger
/Open - Circuit current out solenoid circuit failure signals, Turbo Shut Off Valve Opening
of range Turbine intake Position - Commanded (0x03F0). Refer
solenoid failure to the electrical circuit diagrams and
check the turbine intake solenoid control
circuit for short circuit to ground. Check
power supply to the solenoid. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new turbine intake
solenoid as required

P22CF- Turbocharger Turbine Inlet Harness failure - Using the Jaguar Land Rover approved
4B Valve Control Circuit Turbine intake diagnostic system, check datalogger
/Open - Over temperature solenoid circuit failure signals, Turbo Shut Off Valve Opening
Turbine intake Position - Commanded (0x03F0). Refer
solenoid failure to the electrical circuit diagrams and
check the turbine intake valve control
circuit for short circuit to ground. Check
power supply to the solenoid. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new turbine intake
solenoid as required

P22CF- Turbocharger Turbine Inlet The engine control If this DTC is logged with P22D3-77 &
71 Valve Control Circuit module has not P00BC-00 suspect, turbine intake
/Open - Actuator stuck detected any motion, solenoid sticking closed
in response to If this DTC is logged with P0235-94,
energizing a motor, P00BD-07, P22D2-77 & P1247-00
solenoid or relay suspect, turbine intake solenoid sticking
Turbine intake shut- open
off valve position Check the vacuum system, Charge air
sensor failure shut-off valve and Turbine intake shut-
Turbine intake shut- off valve operation. Refer to section
off valve failure 303-04B or 303-04D and perform
pinpoint test A Vacuum Control System
Tests
If this DTC is logged with P00BD-07,
P22D2-77, P1247-00 & P0235-94
suspect, intake air system, blocked low
pressure air intake
Using the Jaguar Land Rover Approved
Diagnostic Equipment, perform the
(Turbo, EGR and air path dynamic test)
routine

P22D0- Turbocharger Turbine Inlet Harness failure - Using the Jaguar Land Rover approved
00 Valve Control Circuit Low Turbine intake diagnostic system, check datalogger
- No sub type information solenoid circuit failure signals, Turbo Shut Off Valve Opening
Turbine intake Position - Commanded (0x03F0). Refer
solenoid failure to the electrical circuit diagrams and
check the turbine intake solenoid control
circuit for short circuit to ground. Check
power supply to the solenoid. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new turbine intake
solenoid as required

P22D0- Turbocharger Turbine Inlet The engine control Using the Jaguar Land Rover approved
11 Valve Control Circuit Low module has detected a diagnostic system, check datalogger
- Circuit short to ground ground measurement signals, Turbo Shut Off Valve Opening
for a period longer Position - Commanded (0x03F0). Refer
than expected or has to the electrical circuit diagrams and
detected a ground check the turbine intake solenoid control
measurement when circuit on bank 2 for short circuit to
another value was ground. Check power supply to the
expected solenoid. Repair harness as required.
Harness failure - Using the Jaguar Land Rover approved
Turbine intake diagnostic system, clear all stored DTCs
solenoid bank 2 circuit using the ‘Diagnosis Menu’ tab and
short circuit to ground retest
Turbine intake Check and install new turbine intake
solenoid failure solenoid as required

P22D0- Turbocharger Turbine Inlet The engine control Using the Jaguar Land Rover approved
12 Valve Control Circuit Low module has detected a diagnostic system, check datalogger
- Circuit short to battery vehicle power signals, Turbo Shut Off Valve Opening
measurement for a Position - Commanded (0x03F0). Refer
period longer than to the electrical circuit diagrams and
expected or has check the turbine intake solenoid control
detected a vehicle circuit on bank 2 for short circuit to
power measurement power. Check power supply to the
when another value solenoid. Repair harness as required.
was expected Using the Jaguar Land Rover approved
Harness failure - diagnostic system, clear all stored DTCs
Turbine intake using the ‘Diagnosis Menu’ tab and
solenoid bank 2 circuit retest
short circuit to power Check and install new turbine intake
Turbine intake solenoid as required
solenoid failure

P22D1- Turbocharger Turbine Inlet Harness failure - Using the Jaguar Land Rover approved
00 Valve Control Circuit High Turbine intake diagnostic system, check datalogger
- No sub type information solenoid circuit short signals, Turbo Shut Off Valve Opening
circuit to power Position - Commanded (0x03F0). Refer
Turbine intake to the electrical circuit diagrams and
solenoid failure check the turbine intake solenoid control
circuit for short circuit to power. Check
power supply to the solenoid. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new turbine intake
solenoid as required

P22D2- Turbocharger Turbine Inlet The engine control Using the Jaguar Land Rover Approved
77 Valve Stuck Open - module is unable to Diagnostic Equipment, perform the
Commanded position not command a motor, (Turbo, EGR and air path dynamic test)
reachable solenoid or relay, to routine
move a piece of Check the vacuum system, Charge air
equipment to the shut-off valve and Turbine intake shut-
commanded position off valve operation. Refer to section
either due to a failure 303-04B or 303-04D and perform
in the actuator or its pinpoint test A Vacuum Control System
mechanical Tests
environment If this DTC is logged with P0235-94,
P00BD-07, P1247-00 & P22CF-71,
suspect turbine intake solenoid sticking
open
If this DTC is logged with P1247-00,
P0235-94, P00BD-07, & P22CF-71,
suspect blocked low pressure air intake

P22D3- Turbocharger Turbine Inlet The engine control Using the Jaguar Land Rover Approved
77 Valve Stuck Closed - module is unable to Diagnostic Equipment, perform the
Commanded position not command a motor, (Turbo, EGR and air path dynamic test)
reachable solenoid or relay, to routine
move a piece of Refer to the electrical circuit diagrams
equipment to the and check the secondary turbocharger
commanded position charge air shut-off solenoid circuit for
either due to a failure short circuit to ground, short circuit to
in the actuator or its power, open circuit, high resistance
mechanical Check the vacuum system, Charge air
environment shut-off valve and Turbine intake shut-
Connector is off valve operation. Refer to section
disconnected, 303-04B or 303-04D and perform
connector pin is pinpoint test A Vacuum Control System
backed out, connector Tests
pin corrosion If this DTC is logged with P00BC-00, &
Secondary P22CF-71, suspect turbine intake
turbocharger charge solenoid sticking closed
air shut-off solenoid
circuit short circuit to
ground, short circuit to
power, open circuit,
high resistance
Secondary
turbocharger charge
air shut-off valve
system mechanical
integrity
Secondary
turbocharger charge
air shut-off valve
system vacuum
leakage
Secondary
turbocharger charge
air shut-off solenoid
failure

P22D4- Turbocharger Turbine Inlet The engine control Using the Jaguar Land Rover approved
13 Valve Position Sensor module has diagnostic system, perform the (Turbo,
Circuit - Circuit open determined an open EGR and air path dynamic test) routine
circuit via lack of bias Refer to the electrical circuit diagrams
voltage, low current and check turbine intake valve position
flow, no change in the sensor circuit for open circuit, high
state of an input in resistance. Repair harness as required.
response to an output Using the Jaguar Land Rover approved
Turbine intake valve diagnostic system, clear all stored DTCs
position sensor circuit using the ‘Diagnosis Menu’ tab and
open circuit, high retest
resistance

P22D4- Turbocharger Turbine Inlet The engine control Refer to the electrical circuit diagrams
16 Valve Position Sensor module measured a and check turbine intake valve position
Circuit - Circuit voltage voltage below a sensor circuit short circuit to ground.
below threshold specified range but not Repair harness as required. Using the
necessarily a short Jaguar Land Rover approved diagnostic
circuit to ground system, clear all stored DTCs using the
Turbine intake valve ‘Diagnosis Menu’ tab and retest
position sensor circuit
short circuit to ground

P22D4- Turbocharger Turbine Inlet The engine control Refer to the electrical circuit diagrams
17 Valve Position Sensor module measured a and check turbine intake valve position
Circuit - Circuit voltage voltage above a sensor circuit for short circuit to power.
above threshold - Actuator specified range but not Repair harness as required. Using the
stuck necessarily a short Jaguar Land Rover approved diagnostic
circuit to power system, clear all stored DTCs using the
This is the long term ‘Diagnosis Menu’ tab and retest
adaption limit Check and install new turbine intake
diagnostic. It valve position sensor as required
diagnoses that the
adapted values for the
actuator end stops is
outside of tolerance.
This could be caused
by sensor drift over
time
Turbine intake valve
position sensor circuit
short circuit to power
Turbine intake valve
position sensor stuck

P22D4- Turbocharger Turbine Inlet This is the long term Check and install new turbine intake
71 Valve Position Sensor adaption limit valve position sensor as required
Circuit - Actuator stuck diagnostic. It
diagnoses that the
adapted values for the
actuator end stops is
outside of tolerance.
This could be caused
by sensor drift over
time
Turbine intake valve
position sensor stuck

P22D4- Turbocharger Turbine Inlet This is the long term Check and install new turbine intake
92 Valve Position Sensor adaption limit valve position sensor as required
Circuit - Performance or diagnostic. It
incorrect operation diagnoses that the
adapted values for the
actuator end stops is
outside of tolerance.
This could be caused
by sensor drift over
time
Turbine intake valve
position sensor stuck

P22D5- Turbocharger Turbine Inlet This is the long term Check and install new turbine intake
92 Valve Position Sensor adaption limit valve position sensor as required
Circuit Range/Performance diagnostic. It
- Performance or incorrect diagnoses that the
operation adapted values for the
actuator end stops is
outside of tolerance.
This could be caused
by sensor drift over
time
Turbine intake valve
position sensor stuck

P22D6- Turbocharger Turbine Inlet The engine control Refer to the electrical circuit diagrams
11 Valve Position Sensor module has detected a and check turbine intake valve position
Circuit Low - Circuit short ground measurement sensor circuit for short circuit to ground.
to ground for a period longer Repair harness as required. Using the
than expected or has Jaguar Land Rover approved diagnostic
detected a ground system, clear all stored DTCs using the
measurement when ‘Diagnosis Menu’ tab and retest
another value was
expected
Turbine intake valve
position sensor circuit
short circuit to ground

P22D7- Turbocharger Turbine Inlet The engine control Refer to the electrical circuit diagrams
12 Valve Position Sensor module has detected a and check turbine intake valve position
Circuit High - Circuit short vehicle power sensor circuit for short circuit to power.
to battery measurement for a Repair harness as required. Using the
period longer than Jaguar Land Rover approved diagnostic
expected or has system, clear all stored DTCs using the
detected a vehicle ‘Diagnosis Menu’ tab and retest
power measurement
when another value
was expected
Turbine intake valve
position sensor circuit
short circuit to power

P242A- Exhaust Gas Temperature Harness failure - Using the Jaguar Land Rover approved
00 Sensor Circuit Bank 1 Exhaust gas diagnostic system, check datalogger
Sensor 3 - No sub type temperature sensor signals, Exhaust Gas Temperature Bank
information post DPF 1 Sensor 3 (0x03C8), Exhaust Gas
Exhaust gas Temperature Bank 1 Sensor 3 Voltage
temperature sensor (0x03F6). This DTC is set if the exhaust
post DPF failure gas temperature sensor post DPF fails a
cold start diagnostic check by the engine
control module. Refer to the electrical
circuit diagrams and check the exhaust
gas temperature sensor post DPF signal
circuit for open circuit, short circuit to
ground, short circuit to other circuits.
Check the sensor ground circuit for
open circuit, short circuit to power, high
resistance. Repair harness as required
Check and install new exhaust gas
temperature sensor post DPF as required

P242B- Exhaust Gas Temperature Exhaust gas Using the Jaguar Land Rover approved
00 Sensor Circuit temperature sensor diagnostic system, check datalogger
Range/Performance Bank 1 post DPF overheating signals, Exhaust Gas Temperature Bank
Sensor 3 - No sub type Harness failure - 1 Sensor 3 (0x03C8), Exhaust Gas
information Exhaust gas Temperature Bank 1 Sensor 3 Voltage
temperature sensor (0x03F6). This DTC is set if the exhaust
post DPF gas temperature sensor post DPF fails a
Exhaust gas cold start diagnostic check by the engine
temperature sensor control module. Refer to the electrical
post DPF failure circuit diagrams and check the exhaust
gas temperature sensor post DPF signal
circuit for open circuit, short circuit to
ground, short circuit to other circuits.
Check the sensor ground circuit for
open circuit, short circuit to power, high
resistance. Repair harness as required
Clear the DTC and retest
Check and install new exhaust gas
temperature sensor post DPF as required

P242C- Exhaust Gas Temperature Harness failure - Using the Jaguar Land Rover approved
00 Sensor Circuit Low Bank 1 Exhaust gas diagnostic system, check datalogger
Sensor 3 - No sub type temperature sensor signals, Exhaust Gas Temperature Bank
information post DPF 1 Sensor 3 (0x03C8), Exhaust Gas
Exhaust gas Temperature Bank 1 Sensor 3 Voltage
temperature sensor (0x03F6). This DTC is set if the exhaust
post DPF failure gas temperature sensor post DPF signal
voltage is less than the engine control
module was expecting. Refer to the
electrical circuit diagrams and check the
exhaust gas temperature sensor post
DPF signal circuit for open circuit, short
circuit to ground, short circuit to other
circuits. Check the sensor ground circuit
for open circuit, short circuit to power,
high resistance. Repair harness as
required
Check and install new exhaust gas
temperature sensor post DPF as required

P242D- Exhaust Gas Temperature Exhaust gas Using the Jaguar Land Rover approved
00 Sensor Circuit High Bank temperature sensor diagnostic system, check datalogger
1 Sensor 3 - No sub type post DPF circuit, short signals, Exhaust Gas Temperature Bank
information circuit to power, open 1 Sensor 3 (0x03C8), Exhaust Gas
circuit Temperature Bank 1 Sensor 3 Voltage
Exhaust gas (0x03F6)
temperature sensor Refer to the electrical circuit diagrams
post DPF failure and check the exhaust gas temperature
sensor post DPF circuit, for short circuit
to power, open circuit
Check and install new exhaust gas
temperature sensor post DPF as required

P242F- Diesel Particulate Filter Maximum ash load NOTE:


00 Restriction - Ash
Accumulation (Bank 1) - The setting value of this DTC is inhibited
No sub type information
Contact dealer technical support

P244A- Diesel Particulate Filter Diagnostic failure Using the Jaguar Land Rover approved
00 Differential Pressure Too check for minimum diagnostic system, check for related
Low(Bank 1) - No sub type pressure differential DTCs and refer to the relevant DTC
information characteristics index
Diesel particulate filter Clear DTC and re-test
internal components Check and install new diesel particulate
are missing or filter as required
destroyed

P244A- Diesel Particulate Filter Destroyed particulate Refer to the relevant pinpoint test in
96 Differential Pressure Too filter section 309-00
Low(Bank 1) - Component
internal failure
P244B- Diesel Particulate Filter Engine protection NOTE:
68 Differential Pressure Too back pressure high
High (Bank 1) - Event Sudden increases in This DTC when logged on its own is advisory
information differential pressure only and no further action should be taken
across the diesel
particulate filter Using the Jaguar Land Rover approved
diagnostic system, check for related
DTCs. If this DTC exists with any other
diesel particulate filter differential
pressure sensor DTCs, follow the advise
given for that DTC

P244E- Exhaust Temperature Too Error path for not Using the Jaguar Land Rover approved
00 Low For Particulate Filter reaching the setpoint diagnostic system, check for related
Regeneration, Bank 2 - No of the inner loop with DTCs and refer to the relevant DTC
sub type information maximal control index. Clear DTC and re-test. This DTC
variable has been calibrated not to flag

P244F- Exhaust Temperature Too Error path for not Using the Jaguar Land Rover approved
00 High For Particulate Filter reaching the setpoint diagnostic system, check for related
Regeneration, Bank 2 - No of the inner loop with DTCs and refer to the relevant DTC
sub type information minimal control index. Clear DTC and re-test. This DTC
variable has been calibrated not to flag

P2452- Diesel Particulate Filter Differential pressure Refer to the electrical circuit diagrams
23 Pressure Sensor A Circuit - sensor circuit, short and check the differential pressure
Signal stuck low circuit to ground sensor circuit, for short circuit to ground
Diesel differential Using the Jaguar Land Rover approved
pressure sensor A diagnostic system, check for related
circuit, hose line error DTCs and refer to the relevant DTC
index

P2452- Diesel Particulate Filter Diagnostic failure Using the Jaguar Land Rover approved
29 Pressure Sensor A Circuit - check for frozen diagnostic system, check for related
Signal invalid differential pressure DTCs and refer to the relevant DTC
sensor index

P2452- Diesel Particulate Filter NOTE: NOTE:


95 Pressure Sensor A Circuit -
Incorrect assembly In cold climates differentialIf a new diesel particulate filter pressure
pressure sensor hose lines orsensor or hose lines have been installed or
metal pipes may be frozen incorrectly routed, or any pressure sensor
circuit repairs carried out, the engine control
Differential pressure module must learn and store the new diesel
sensor hoses particulate filter pressure sensor offset value.
connected incorrectly The following conditions must be met to allow
Differential pressure the diesel particulate filter pressure sensor
sensor hoses crushed, offset value to be learnt and stored: Using the
blocked, split Jaguar Land Rover approved diagnostic
system, clear DTCs from engine control
module, then monitor the datalogger signal
'sump oil temperature - measured' ensuring a
minimum of 50°C is achieved. Start engine,
run above 500RPM for 2 minutes, then a
further 30 seconds at idle. Ensure the engine
cooling fan is not running. Set vehicle in park
and set ignition status to off. Wait 30 seconds
for the engine control module to power down,
learn and store diesel particulate filter pressure
sensor offset value. This process must be
carried out six times, to allow a large negative
offset value to adapt back to 0 Hpa

Using the Jaguar Land Rover approved


diagnostic system, check datalogger
signals, Particulate Filter Differential
Pressure Sensor Voltage - Bank 1
(0x03DB). Refer to the workshop
manual and check differential pressure
sensor hoses are installed correctly
Check differential pressure sensor hoses
for crushed, blockage, split

P2453- Diesel Particulate Filter Harness failure - NOTE:


00 Pressure Sensor A Circuit Differential pressure
Range/Performance - No sensor If a new diesel particulate filter pressure
sub type information Differential pressure sensor or hose lines have been installed or
sensor failure incorrectly routed, or any pressure sensor
circuit repairs carried out, the engine control
module must learn and store the new diesel
particulate filter pressure sensor offset value.
The following conditions must be met to allow
the diesel particulate filter pressure sensor
offset value to be learnt and stored: Using the
Jaguar Land Rover approved diagnostic
system, clear DTCs from engine control
module, then monitor the datalogger signal
'sump oil temperature - measured' ensuring a
minimum of 50°C is achieved. Start engine,
run above 500RPM for 2 minutes, then a
further 30 seconds at idle. Ensure the engine
cooling fan is not running. Set vehicle in park
and set ignition status to off. Wait 30 seconds
for the engine control module to power down,
learn and store diesel particulate filter pressure
sensor offset value. This process must be
carried out six times, to allow a large negative
offset value to adapt back to 0 Hpa

Using the Jaguar Land Rover approved


diagnostic system, check datalogger
signals, Particulate Filter Differential
Pressure Sensor Voltage - Bank 1
(0x03DB). This DTC is set when the
particulate pressure sensor fails a
plausibility check. Refer to the electrical
circuit diagrams and check the
differential pressure sensor signal circuit
for open circuit, short circuit to ground,
short circuit to other circuits. Check the
sensor ground circuit for open circuit,
short circuit to power, high resistance.
Check the sensor power supply circuit
for open circuit, short circuit to ground,
high resistance. Repair harness as
required
Check and install new differential
pressure sensor as required

P2453- Diesel Particulate Filter Diagnostic failure Using the Jaguar Land Rover approved
16 Pressure Sensor A Circuit check for signal range diagnostic system, check for related
Range/Performance - check low in flow DTCs and refer to the relevant DTC
Circuit voltage below resistance index
threshold Harness failure - Using the Jaguar Land Rover approved
Differential pressure diagnostic system, check datalogger
sensor signals, Particulate Filter Differential
Differential pressure Pressure Sensor Voltage - Bank 1
sensor failure (0x03DB). This DTC is set when the
particulate pressure sensor fails a
plausibility check. Refer to the electrical
circuit diagrams and check the
differential pressure sensor signal circuit
for open circuit, short circuit to ground,
short circuit to other circuits. Check the
sensor ground circuit for open circuit,
short circuit to power, high resistance.
Check the sensor power supply circuit
for open circuit, short circuit to ground,
high resistance. Repair harness as
required
Check and install new differential
pressure sensor as required

P2453- Diesel Particulate Filter Diagnostic failure Using the Jaguar Land Rover approved
17 Pressure Sensor A Circuit check for signal range diagnostic system, check for related
Range/Performance - check high in flow DTCs and refer to the relevant DTC
Circuit voltage above resistance index
threshold Harness failure - Using the Jaguar Land Rover approved
Differential pressure diagnostic system, check datalogger
sensor signals, Particulate Filter Differential
Differential pressure Pressure Sensor Voltage - Bank 1
sensor failure (0x03DB). This DTC is set when the
particulate pressure sensor fails a
plausibility check. Refer to the electrical
circuit diagrams and check the
differential pressure sensor signal circuit
for open circuit, short circuit to ground,
short circuit to other circuits. Check the
sensor ground circuit for open circuit,
short circuit to power, high resistance.
Check the sensor power supply circuit
for open circuit, short circuit to ground,
high resistance. Repair harness as
required
Check and install new differential
pressure sensor as required

P2454- Diesel Particulate Filter Harness failure - NOTE:


00 Pressure Sensor A Circuit Differential pressure
Low - No sub type sensor If a new diesel particulate filter pressure
information Differential pressure sensor or hose lines have been installed or
sensor crossed hose incorrectly routed, or any pressure sensor
lines circuit repairs carried out, the engine control
Differential pressure module must learn and store the new diesel
sensor failure particulate filter pressure sensor offset value.
The following conditions must be met to allow
the diesel particulate filter pressure sensor
offset value to be learnt and stored: Using the
Jaguar Land Rover approved diagnostic
system, clear DTCs from engine control
module, then monitor the datalogger signal
'sump oil temperature - measured' ensuring a
minimum of 50°C is achieved. Start engine,
run above 500RPM for 2 minutes, then a
further 30 seconds at idle. Ensure the engine
cooling fan is not running. Set vehicle in park
and set ignition status to off. Wait 30 seconds
for the engine control module to power down,
learn and store diesel particulate filter pressure
sensor offset value. This process must be
carried out six times, to allow a large negative
offset value to adapt back to 0 Hpa

Using the Jaguar Land Rover approved


diagnostic system, check datalogger
signals, Particulate Filter Differential
Pressure Sensor Voltage - Bank 1
(0x03DB). This DTC is set when the
particulate pressure sensor voltage is
less than the threshold set in the engine
control module diagnostic check. Refer
to the electrical circuit diagrams and
check the differential pressure sensor
signal circuit for open circuit, short
circuit to ground, short circuit to other
circuits. Check the sensor ground circuit
for open circuit, short circuit to power,
high resistance. Check the sensor power
supply circuit for open circuit, short
circuit to ground, high resistance. Repair
harness as required
Check differential pressure sensor hose
lines are installed correctly
Check and install new differential
pressure sensor as required

P2455- Diesel Particulate Filter Harness failure - NOTE:


00 Pressure Sensor A Circuit Differential pressure
High - No sub type sensor If a new diesel particulate filter pressure
information Differential pressure sensor or hose lines have been installed or
sensor failure incorrectly routed, or any pressure sensor
Exhaust back pressure circuit repairs carried out, the engine control
is too high module must learn and store the new diesel
particulate filter pressure sensor offset value.
The following conditions must be met to allow
the diesel particulate filter pressure sensor
offset value to be learnt and stored: Using the
Jaguar Land Rover approved diagnostic
system, clear DTCs from engine control
module, then monitor the datalogger signal
'sump oil temperature - measured' ensuring a
minimum of 50°C is achieved. Start engine,
run above 500RPM for 2 minutes, then a
further 30 seconds at idle. Ensure the engine
cooling fan is not running. Set vehicle in park
and set ignition status to off. Wait 30 seconds
for the engine control module to power down,
learn and store diesel particulate filter pressure
sensor offset value. This process must be
carried out six times, to allow a large negative
offset value to adapt back to 0 Hpa

Using the Jaguar Land Rover approved


diagnostic system, check engine control
module, for related DTCs and refer to
the relevant DTC index
Using the Jaguar Land Rover approved
diagnostic system, check datalogger
signals, Particulate Filter Differential
Pressure Sensor Voltage - Bank 1
(0x03DB). This DTC is set when the
particulate pressure sensor voltage is
greater than the threshold set in the
engine control module diagnostic check.
Refer to the electrical circuit diagrams
and check the differential pressure
sensor signal circuit for open circuit,
short circuit to power, short circuit to
other circuits. Check the sensor ground
circuit for open circuit, short circuit to
power, high resistance. Check the sensor
power supply circuit for open circuit,
short circuit to ground, high resistance.
Repair harness as required
Check and install new differential
pressure sensor as required

P2456- Diesel Particulate Filter Differential pressure NOTE:


00 Pressure Sensor A Circuit sensor circuit short
Intermittent/Erratic - No circuit to ground, short If a new diesel particulate filter pressure
sub type information circuit to power, open sensor or hose lines have been installed or
circuit, high resistance incorrectly routed, or any pressure sensor
In cold climate or off circuit repairs carried out, the engine control
road driving module must learn and store the new diesel
differential pressure particulate filter pressure sensor offset value.
sensor hoses crushed, The following conditions must be met to allow
blocked, split the diesel particulate filter pressure sensor
Differential pressure offset value to be learnt and stored: Using the
sensor failure Jaguar Land Rover approved diagnostic
system, clear DTCs from engine control
module, then monitor the datalogger signal
'sump oil temperature - measured' ensuring a
minimum of 50°C is achieved. Start engine,
run above 500RPM for 2 minutes, then a
further 30 seconds at idle. Ensure the engine
cooling fan is not running. Set vehicle in park
and set ignition status to off. Wait 30 seconds
for the engine control module to power down,
learn and store diesel particulate filter pressure
sensor offset value. This process must be
carried out six times, to allow a large negative
offset value to adapt back to 0 Hpa

Refer to the electrical circuit diagrams


and check differential pressure sensor
circuit for short circuit to ground, short
circuit to power, open circuit, high
resistance
Inspect connectors for signs of water
ingress and pins for damage and/or
corrosion
Check differential pressure sensor hoses
for crushed, blocked, split
Check and replace diesel particulate
filter differential pressure sensor as
required

P2458- Diesel Particulate Filter Permanent NOTE:


66 Regeneration Duration regeneration
(Bank 1) - Signal has too This code is enabled for JLR engineering
many transitions/events detailed diagnostics only. No further action
should be taken

Using the Jaguar Land Rover approved


diagnostic system, check for related
DTCs and refer to the relevant DTC
index

P2459- Diesel Particulate Filter Blocked regeneration NOTE:


65 Regeneration Frequency Customer driving
(Bank 1) - Signal has too routine does not allow If DTC is P2459-65 or AMBER DPF FULL
few transitions/events the system to clean the REFER TO HANDBOOK message is
particulate filter displayed with no other reported messages. No
repair is required, if the vehicle is driven on a
highway AS DIRECTED IN THE
HANDBOOK then the light will be
extinguished and the system self healed,
nothing more than this is required

Refer to the diesel particulate filter


regeneration procedure and carry out a
diesel particulate filter regeneration
Advise customer of driving routine
required to regenerate diesel particulate
filter as stated in the vehicle handbook

P2459- Diesel Particulate Filter Regeneration NOTE:


66 Regeneration Frequency frequency
(Bank 1) - Signal has too This code is enabled for JLR engineering
many transitions/events detailed diagnostics only. No further action
should be taken

Using the Jaguar Land Rover approved


diagnostic system, check for related
DTCs and refer to the relevant DTC
index

P245A- Exhaust Gas Recirculation The engine control Using the Jaguar Land Rover approved
11 Cooler Bypass Control module has detected a diagnostic system, check datalogger
Circuit - Circuit short to ground measurement signals, EGR Cooler Bypass Valve Duty
ground for a period longer Cycle (0x03C5). Refer to the electrical
than expected or has circuit diagrams and check the exhaust
detected a ground gas recirculation bypass solenoid circuit
measurement when for short circuit to ground. Check power
another value was supply to the solenoid. Repair harness as
expected required. Using the Jaguar Land Rover
Harness failure - approved diagnostic system, clear all
Exhaust gas stored DTCs using the ‘Diagnosis
recirculation bypass Menu’ tab and retest
solenoid circuit short
circuit to ground

P245A- Exhaust Gas Recirculation The engine control Using the Jaguar Land Rover approved
12 Cooler Bypass Control module has detected a diagnostic system, check datalogger
Circuit - Circuit short to vehicle power signals, EGR Cooler Bypass Valve Duty
battery measurement for a Cycle (0x03C5). Refer to the electrical
period longer than circuit diagrams and check the exhaust
expected or has gas recirculation bypass solenoid circuit
detected a vehicle for short circuit to power. Check power
power measurement supply to the solenoid. Repair harness as
when another value required. Using the Jaguar Land Rover
was expected approved diagnostic system, clear all
Harness failure - stored DTCs using the ‘Diagnosis
Exhaust gas Menu’ tab and retest
recirculation bypass Check and install new exhaust gas
solenoid circuit short recirculation bypass solenoid as
circuit to power required
Exhaust gas
recirculation bypass
solenoid failure

P245A- Exhaust Gas Recirculation The engine control Using the Jaguar Land Rover approved
13 Cooler Bypass Control module has diagnostic system, check datalogger
Circuit - Circuit open determined an open signals, EGR Cooler Bypass Valve Duty
circuit via lack of bias Cycle (0x03C5). Refer to the electrical
voltage, low current circuit diagrams and check the exhaust
flow, no change in the gas recirculation bypass solenoid circuit
state of an input in for open circuit. Check power supply to
response to an output the solenoid. Repair harness as required.
Harness failure - Using the Jaguar Land Rover approved
Exhaust gas diagnostic system, clear all stored DTCs
recirculation bypass using the ‘Diagnosis Menu’ tab and
solenoid circuit open retest
circuit Check and install new exhaust gas
Exhaust gas recirculation bypass solenoid as
recirculation bypass required
solenoid failure

P245B- Exhaust Gas Recirculation Harness failure - Using the Jaguar Land Rover approved
19 Cooler Bypass Control Exhaust gas diagnostic system, check datalogger
Circuit Range/Performance recirculation bypass signals, EGR Cooler Bypass Valve Duty
- Circuit current above solenoid circuit short Cycle (0x03C5). Refer to the electrical
threshold circuit to ground, high circuit diagrams and check the exhaust
resistance gas recirculation bypass solenoid circuit
Exhaust gas for short circuit to ground, high
recirculation bypass resistance. Repair harness as required.
solenoid failure Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new exhaust gas
recirculation bypass solenoid as
required

P2463- Diesel Particulate Filter Maximum soot mass Refer to the relevant pinpoint test in
00 Restriction - Soot section 309-00
Accumulation (Bank 1) -
No sub type information
P246C- Diesel Particulate Filter Diagnostic failure Using the Jaguar Land Rover approved
00 Restriction - Forced check for maximum diagnostic system, check for related
Limited Power (Bank 1) - pressure differential DTCs and refer to the relevant DTC
No sub type information characteristics index

P250A- Engine Oil Level Sensor The engine control Using the Jaguar Land Rover approved
36 Circuit - Signal frequency module detected diagnostic system, check datalogger
too low excessive duration for signals, Engine Oil Level - Measured
one cycle of the output (0x03E6), Engine Oil Volume -
across a specified Calculated (0x03F2), Sump Oil
sample size Temperature - Measured (0x03F3).
Oil level and Refer to the electrical circuit diagrams
temperature sensor and check the oil level and temperature
circuit short circuit to sensor circuit for short circuit to ground,
ground, high high resistance, open circuit. Repair
resistance, open circuit harness as required. Using the Jaguar
Oil level and Land Rover approved diagnostic
temperature sensor system, clear all stored DTCs using the
failure ‘Diagnosis Menu’ tab and retest
Check and install new oil level and
temperature sensor as required

P250A- Engine Oil Level Sensor The engine control Using the Jaguar Land Rover approved
37 Circuit - Signal frequency module detected diagnostic system, check datalogger
too high insufficient duration signals, Engine Oil Level - Measured
for one cycle of the (0x03E6), Engine Oil Volume -
output across a Calculated (0x03F2), Sump Oil
specified sample size Temperature - Measured (0x03F3).
Oil level and Refer to the electrical circuit diagrams
temperature sensor and check the oil level and temperature
circuit short circuit to sensor circuit for short circuit to power.
power Repair harness as required. Using the
Oil level and Jaguar Land Rover approved diagnostic
temperature sensor system, clear all stored DTCs using the
failure ‘Diagnosis Menu’ tab and retest
Check and install new oil level and
temperature sensor as required

P250A- Engine Oil Level Sensor Oil level and Using the Jaguar Land Rover approved
38 Circuit - Signal frequency temperature sensor diagnostic system, check datalogger
incorrect circuit short circuit to signals, Engine Oil Level - Measured
ground, short circuit to (0x03E6), Engine Oil Volume -
power, high resistance, Calculated (0x03F2), Sump Oil
open circuit Temperature - Measured (0x03F3).
Oil level and Refer to the electrical circuit diagrams
temperature sensor and check the oil level and temperature
failure sensor circuit for short circuit to ground,
short circuit to power, high resistance,
open circuit. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new oil level and
temperature sensor as required

P250A- Engine Oil Level Sensor Oil level and Using the Jaguar Land Rover approved
47 Circuit - Watchdog/safety temperature sensor diagnostic system, check datalogger
micro controller failure circuit short circuit to signals, Engine Oil Level - Measured
ground, short circuit to (0x03E6), Engine Oil Volume -
power, high resistance, Calculated (0x03F2), Sump Oil
open circuit Temperature - Measured (0x03F3).
Oil level and Refer to the electrical circuit diagrams
temperature sensor and check the oil level and temperature
failure sensor circuit for short circuit to ground,
short circuit to power, high resistance,
open circuit. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new oil level and
temperature sensor as required

P250A- Engine Oil Level Sensor Oil level and Using the Jaguar Land Rover approved
92 Circuit - Performance or temperature sensor diagnostic system, check datalogger
incorrect operation circuit short circuit to signals, Engine Oil Level - Measured
ground, short circuit to (0x03E6), Engine Oil Volume -
power, high resistance, Calculated (0x03F2), Sump Oil
open circuit Temperature - Measured (0x03F3).
Oil level and Refer to the electrical circuit diagrams
temperature sensor and check the oil level and temperature
failure sensor circuit for short circuit to ground,
short circuit to power, high resistance,
open circuit. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Check and install new oil level and
temperature sensor as required

P2586- Turbocharger Boost The engine control Using the Jaguar Land Rover approved
13 Control Position Sensor B module has diagnostic system, check datalogger
Circuit - Circuit open determined an open signal, Boost Pressure Actuator Bank 2 -
circuit via lack of bias Measured Position (0x0347). Refer to
voltage, low current the electrical circuit diagrams and check
flow, no change in the the variable geometry turbine vane
state of an input in actuator on bank 1 for open circuit. This
response to an output circuit consists of three wires between
Harness failure - the engine control module and the
Variable geometry variable geometry turbocharger control
turbine vane actuator module. The three sensor wires are a 5
open circuit volt sensor supply, a sensor ground and
Variable geometry a signal line. Check signal line for open
turbine vane actuator circuit and power and ground supply to
failure sensor. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, clear all stored DTCs
using the ‘Diagnosis Menu’ tab and
retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Turbocharger
Check and install new variable
geometry turbocharger position sensor
as required

P2586- Turbocharger Boost Harness failure - Using the Jaguar Land Rover approved
32 Control Position Sensor B Variable geometry diagnostic system, check datalogger
Circuit - Signal low time < turbine vane actuator signal, Boost Pressure Actuator Bank 2 -
minimum circuit short circuit to Measured Position (0x0347). Refer to
ground, high the electrical circuit diagrams and check
resistance, open circuit the variable geometry turbine vane
Variable geometry actuator on bank 1 for short circuit to
turbine vane actuator ground, high resistance, open circuit.
failure Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Turbocharger
Check and install new variable
geometry turbocharger position sensor
as required

P2586- Turbocharger Boost Harness failure - Using the Jaguar Land Rover approved
35 Control Position Sensor B Variable geometry diagnostic system, check datalogger
Circuit - Signal high time > turbine vane actuator signal, Boost Pressure Actuator Bank 2 -
maximum Variable geometry Measured Position (0x0347). Refer to
turbine vane actuator the electrical circuit diagrams and check
failure the variable geometry turbine vane
actuator on bank 1 for open circuit,
short circuit to power, short circuit to
ground. Check the power and ground
supply to the sensor. Repair harness as
required. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Turbocharger
Check and install new variable
geometry turbocharger position sensor
as required

P2586- Turbocharger Boost The engine control Using the Jaguar Land Rover approved
36 Control Position Sensor B module detected diagnostic system, check datalogger
Circuit - Signal frequency excessive duration for signal, Boost Pressure Actuator Bank 2 -
too low one cycle of the output Measured Position (0x0347). Refer to
across a specified the electrical circuit diagrams and check
sample size the variable geometry turbine vane
Harness failure - actuator on bank 1 for open circuit,
Variable geometry short circuit to power, short circuit to
turbine vane actuator ground. Check the power and ground
Variable geometry supply to the sensor. Repair harness as
turbine vane actuator required. Using the Jaguar Land Rover
failure approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Turbocharger
Check and install new variable
geometry turbocharger position sensor
as required

P2586- Turbocharger Boost The engine control Using the Jaguar Land Rover approved
37 Control Position Sensor B module detected diagnostic system, check datalogger
Circuit - Signal frequency insufficient duration signal, Boost Pressure Actuator Bank 2 -
too high for one cycle of the Measured Position (0x0347). Refer to
output across a the electrical circuit diagrams and check
specified sample size the variable geometry turbine vane
Harness failure - actuator on bank 1 for open circuit,
Variable geometry short circuit to power, short circuit to
turbine vane actuator ground. Check the power and ground
Variable geometry supply to the sensor. Repair harness as
turbine vane actuator required. Using the Jaguar Land Rover
failure approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Check and install new variable
geometry turbocharger position sensor
as required

P2587- Turbocharger Boost Harness failure - Using the Jaguar Land Rover approved
92 Control Position Sensor B Variable geometry diagnostic system, check datalogger
Circuit Range/Performance turbine vane actuator signal, Boost Pressure Actuator Bank 2 -
- Performance or incorrect Variable geometry Measured Position (0x0347). Refer to
operation turbine vane actuator the electrical circuit diagrams and check
failure the variable geometry turbine vane
actuator on bank 1 for open circuit,
short circuit to power, short circuit to
ground. Check the power and ground
supply to the sensor. Repair harness as
required. Using the Jaguar Land Rover
approved diagnostic system, clear all
stored DTCs using the ‘Diagnosis
Menu’ tab and retest
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Turbocharger
Check and install new variable
geometry turbocharger position sensor
as required

P2588- Turbocharger Boost Harness failure - Using the Jaguar Land Rover approved
00 Control Position Sensor B Variable geometry diagnostic system, check datalogger
Circuit Low - No sub type turbine vane actuator signal, Boost Pressure Actuator Bank 2 -
information Variable geometry Measured Position (0x0347). This DTC
turbine vane actuator is set when the engine control module
circuit short circuit to detects a low circuit voltage on the
ground signal line from the variable geometry
Variable geometry turbine vane actuator. Check signal line
turbine vane actuator for short circuit to ground. Check power
failure and ground supply to sensor. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Refer to the electrical circuit diagrams
and check variable geometry turbine
vane actuator circuit for short circuit to
ground
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Turbocharger
Check and install new variable
geometry turbine vane actuator as
required

P2589- Turbocharger Boost Harness failure - Using the Jaguar Land Rover approved
00 Control Position Sensor B Variable geometry diagnostic system, check datalogger
Circuit High - No sub type turbine vane actuator signal, Boost Pressure Actuator Bank 2 -
information Variable geometry Measured Position (0x0347). This DTC
turbine vane actuator is set when the engine control module
circuit short circuit to detects a high circuit voltage on the
power signal line from the variable geometry
Variable geometry turbine vane actuator. Check signal line
turbine vane actuator for short circuit to power. Check power
failure and ground supply to sensor. Repair
harness as required. Using the Jaguar
Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Refer to the electrical circuit diagrams
and check variable geometry turbine
vane actuator circuit for short circuit to
power
Using the Jaguar Land Rover approved
diagnostic system, perform routine -
Inline diagnostic unit 2 diagnostic test -
Turbocharger
Check and install new variable
geometry turbine vane actuator as
required

P25A2- Brake System Control MIL request by anti- Check anti-lock brake system control
00 Module Requested MIL lock brake system module for DTCs and refer to the
Illumination - No sub type control module relevant DTC index. Using the Jaguar
information HS CAN network, Land Rover approved diagnostic
short circuit to power, system, clear all stored DTCs using the
short circuit to ground, ‘Diagnosis Menu’ tab and retest
open circuit If this DTC is logged with other HS
CAN related DTCs refer to the electrical
circuit diagrams and check HS CAN
network for short circuit to power, short
circuit to ground, open circuit

P268C- Cylinder 1 Injector Data Injector calibration Using the Jaguar Land Rover approved
00 Incompatible - No sub type data held in the engine diagnostic system, reprogram the
information control module is injector codes
different to that read
from the injector
Injector calibration
data not stored
/programmed
P268C- Cylinder 1 Injector Data Injector calibration Using the Jaguar Land Rover approved
51 Incompatible - Not data held in the engine diagnostic system, reprogram the
programmed control module is injector codes
different to that read
from the injector
Injector calibration
data not stored
/programmed

P268D- Cylinder 2 Injector Data Injector calibration Using the Jaguar Land Rover approved
00 Incompatible - No sub type data held in the engine diagnostic system, reprogram the
information control module is injector codes
different to that read
from the injector
Injector calibration
data not stored
/programmed

P268D- Cylinder 2 Injector Data Injector calibration Using the Jaguar Land Rover approved
51 Incompatible - Not data held in the engine diagnostic system, reprogram the
programmed control module is injector codes
different to that read
from the injector
Injector calibration
data not stored
/programmed

P268E- Cylinder 3 Injector Data Injector calibration Using the Jaguar Land Rover approved
00 Incompatible - No sub type data held in the engine diagnostic system, reprogram the
information control module is injector codes
different to that read
from the injector
Injector calibration
data not stored
/programmed

P268E- Cylinder 3 Injector Data Injector calibration Using the Jaguar Land Rover approved
51 Incompatible - Not data held in the engine diagnostic system, reprogram the
programmed control module is injector codes
different to that read
from the injector
Injector calibration
data not stored
/programmed

P268F- Cylinder 4 Injector Data Injector calibration Using the Jaguar Land Rover approved
00 Incompatible - No sub type data held in the engine diagnostic system, reprogram the
information control module is injector codes
different to that read
from the injector
Injector calibration
data not stored
/programmed

P268F- Cylinder 4 Injector Data Injector calibration Using the Jaguar Land Rover approved
51 Incompatible - Not data held in the engine diagnostic system, reprogram the
programmed control module is injector codes
different to that read
from the injector
Injector calibration
data not stored
/programmed

P2690- Cylinder 5 Injector Data Injector calibration Using the Jaguar Land Rover approved
00 Incompatible - No sub type data held in the engine diagnostic system, reprogram the
information control module is injector codes
different to that read
from the injector
Injector calibration
data not stored
/programmed

P2690- Cylinder 5 Injector Data Injector calibration Using the Jaguar Land Rover approved
51 Incompatible - Not data held in the engine diagnostic system, reprogram the
programmed control module is injector codes
different to that read
from the injector
Injector calibration
data not stored
/programmed

P2691- Cylinder 6 Injector Data Injector calibration Using the Jaguar Land Rover approved
00 Incompatible - No sub type data held in the engine diagnostic system, reprogram the
information control module is injector codes
different to that read
from the injector
Injector calibration
data not stored
/programmed

P2691- Cylinder 6 Injector Data Injector calibration Using the Jaguar Land Rover approved
51 Incompatible - Not data held in the engine diagnostic system, reprogram the
programmed control module is injector codes
different to that read
from the injector
Injector calibration
data not stored
/programmed

P2A00- O2 Circuit Range The engine control This DTC is set when the engine control
16 /Performance (Bank 1, module measured a module detects the voltage on the trim
Sensor 1) - Circuit voltage voltage below a resistor circuit of the heated oxygen
below threshold specified range but not sensor is less than the voltage threshold.
necessarily a short This may be caused by the heated
circuit to ground oxygen sensor being too hot to operate
Harness failure - correctly. Refer to the workshop manual
Heated oxygen sensor and check the exhaust system and
failure heated oxygen sensor harness for sign of
Heated oxygen sensor mechanical damage. Refer to the
failure electrical circuit diagrams and check all
the heated oxygen sensor circuits for
open circuits, short circuit to power,
short circuit to ground, short circuit to
other circuits. Check all engine control
module power and ground supplies.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new heated oxygen
sensor as required

P2A00- O2 Circuit Range The engine control This DTC is set when the engine control
17 /Performance (Bank 1, module measured a module detects the voltage on the trim
Sensor 1) - Circuit voltage voltage above a resistor circuit of the heated oxygen
above threshold specified range but not sensor is greater than the voltage
necessarily a short threshold. This may be caused by the
circuit to power heated oxygen sensor being too hot to
Harness failure - operate correctly. Refer to the workshop
Heated oxygen sensor manual and check the exhaust system
failure and heated oxygen sensor harness for
Heated oxygen sensor sign of mechanical damage. Refer to the
failure electrical circuit diagrams and check all
the heated oxygen sensor circuits for
open circuits, short circuit to power,
short circuit to ground, short circuit to
other circuits. Check all engine control
module power and ground supplies.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new heated oxygen
sensor as required

P2A00- O2 Circuit Range Harness failure - This DTC is set when the engine control
26 /Performance (Bank 1, Heated oxygen sensor module detects the voltage on the trim
Sensor 1) - Signal rate of failure resistor circuit of the heated oxygen
change below threshold Heated oxygen sensor sensor is greater than the voltage
failure threshold. This may be caused by the
heated oxygen sensor being too hot to
operate correctly. Refer to the workshop
manual and check the exhaust system
and heated oxygen sensor harness for
sign of mechanical damage. Refer to the
electrical circuit diagrams and check all
the heated oxygen sensor circuits for
open circuits, short circuit to power,
short circuit to ground, short circuit to
other circuits. Check all engine control
module power and ground supplies.
Repair harness as required. Using the
Jaguar Land Rover approved diagnostic
system, clear all stored DTCs using the
‘Diagnosis Menu’ tab and retest
Check and install new heated oxygen
sensor as required
U0001- High Speed CAN High speed CAN bus Using the Jaguar Land Rover approved
00 Communication Bus - No failure diagnostic system, carry out network
sub type information High speed CAN bus integrity test
circuit, short circuit to Refer to the electrical circuit diagrams
ground, short circuit to and check high speed CAN network for
power, open circuit short circuit to ground, short circuit to
power, open circuit

U0001- High Speed CAN High speed CAN bus Using the Jaguar Land Rover approved
88 Communication Bus - Bus failure diagnostic system, carry out network
off High speed CAN bus integrity test
circuit, short circuit to Refer to the electrical circuit diagrams
ground, short circuit to and check high speed CAN network for
power, open circuit short circuit to ground, short circuit to
power, open circuit

U0101- Lost Communication with The engine control Using the Jaguar Land Rover approved
00 TCM - No sub type module has not diagnostic system, check transmission
information received the expected control module for DTCs and refer to
CAN signal from the the relevant DTC index
transmission control Using the Jaguar Land Rover approved
module within the diagnostic system, carry out network
specified time interval integrity test. Refer to the electrical
CAN harness link circuit diagrams and check transmission
between engine control module power and ground
control module and circuits for open circuit. Check CAN
transmission control harness between engine control module
module network and transmission control module, repair
malfunction as necessary

U0101- Lost Communication with The engine control Using the Jaguar Land Rover approved
26 TCM - Signal rate of module has not diagnostic system, check transmission
change below threshold received the expected control module for DTCs and refer to
CAN signal from the the relevant DTC index
transmission control Using the Jaguar Land Rover approved
module within the diagnostic system, carry out network
specified time interval integrity test. Refer to the electrical
CAN harness link circuit diagrams and check transmission
between engine control module power and ground
control module and circuits for open circuit. Check CAN
transmission control harness between engine control module
module network and transmission control module, repair
malfunction as necessary

U0102- Lost Communication with The engine control Using the Jaguar Land Rover approved
00 Transfer Case Control module has not diagnostic system, check transfer box
Module - No sub type received the expected control module for DTCs and refer to
information CAN signal from the the relevant DTC index
transfer box control Using the Jaguar Land Rover approved
module within the diagnostic system, carry out network
specified time interval integrity test. Refer to the electrical
CAN harness link circuit diagrams and check transfer box
between engine control module power and ground
control module and circuits for open circuit. Check CAN
transfer box control harness between engine control module
module network and transfer box control module, repair
malfunction as necessary

U0103- Lost Communication With The engine control Using the Jaguar Land Rover approved
00 Gear Shift Control Module module has not diagnostic system, check transmission
A - No sub type received the expected control switch for DTCs and refer to the
information CAN signal from the relevant DTC index
transmission control Using the Jaguar Land Rover approved
switch within the diagnostic system, carry out network
specified time interval integrity test. Refer to the electrical
CAN harness link circuit diagrams and check transmission
between engine control switch power and ground
control module and circuits for open circuit. Check CAN
transmission control harness between engine control module
switch network and transmission control switch, repair
malfunction as necessary

U0104- Lost Communication With The engine control Using the Jaguar Land Rover approved
00 Cruise Control Module - module has not diagnostic system, check speed control
No sub type information received the expected module for DTCs and refer to the
CAN signal from the relevant DTC index
speed control module Using the Jaguar Land Rover approved
within the specified diagnostic system, carry out network
time interval integrity test. Refer to the electrical
CAN harness link circuit diagrams and check speed
between engine control module power and ground
control module and circuits for open circuit. Check CAN
speed control module harness between engine control module
network malfunction and speed control module, repair as
necessary

U0120- Lost Communication with The engine control Using the Jaguar Land Rover approved
00 Starter/Generator Control module has not diagnostic system, check anti-lock brake
Module - No sub type received the expected system control module for DTCs and
information CAN signal from the refer to the relevant DTC index
anti-lock brake system Using the Jaguar Land Rover approved
control module within diagnostic system, carry out network
the specified time integrity test. Refer to the electrical
interval circuit diagrams and check generator
CAN harness link system control module power and
between engine ground circuits for open circuit. Check
control module and CAN harness between engine control
anti-lock brake system module and anti-lock brake system
control module control module, repair as necessary
network malfunction

U0121- Lost Communication With The engine control Using the Jaguar Land Rover approved
00 Anti-Lock Brake System module has not diagnostic system, check anti-lock brake
(ABS) Control Module - received the expected system control module for DTCs and
No sub type information CAN signal from the refer to the relevant DTC index
anti-lock brake system Using the Jaguar Land Rover approved
control module within diagnostic system, carry out network
the specified time integrity test. Refer to the electrical
interval circuit diagrams and check anti-lock
CAN harness link brake system control module power and
between engine ground circuits for open circuit. Check
control module and CAN harness between engine control
anti-lock brake system module and anti-lock brake system
control module control module, repair as necessary
network malfunction

U0126- Lost Communication With The engine control Using the Jaguar Land Rover approved
00 Steering Angle Sensor module has not diagnostic system, check steering angle
Module - No sub type received the expected sensor control module for DTCs and
information CAN signal from the refer to the relevant DTC index
steering angle sensor Using the Jaguar Land Rover approved
control module within diagnostic system, carry out network
the specified time integrity test. Refer to the electrical
interval circuit diagrams and check steering
CAN harness link angle sensor control module power and
between engine ground circuits for open circuit. Check
control module and CAN harness between engine control
steering angle sensor module and steering angle sensor
control module control module, repair as necessary
network malfunction

U0128- Lost Communication With The engine control Using the Jaguar Land Rover approved
00 Park Brake Control module has not diagnostic system, check park brake
Module - No sub type received the expected control module for DTCs and refer to
information CAN signal from the the relevant DTC index
park brake control Using the Jaguar Land Rover approved
module within the diagnostic system, carry out network
specified time interval integrity test. Refer to the electrical
CAN harness link circuit diagrams and check park brake
between engine control module power and ground
control module and circuits for open circuit. Check CAN
park brake control harness between engine control module
module network and park brake control module, repair as
malfunction necessary

U012A- Lost Communication with The engine control Using the Jaguar Land Rover approved
00 Chassis Control Module module has not diagnostic system, check integrated
"A" - No sub type received the expected suspension control module for DTCs
information CAN signal from the and refer to the relevant DTC index
integrated suspension Using the Jaguar Land Rover approved
control module within diagnostic system, complete a CAN
the specified time network integrity test
interval Refer to the electrical circuit diagrams
CAN harness link and check integrated suspension control
between engine module power and ground circuits for
control module and open circuit
integrated suspension Check CAN harness between engine
control module control module and integrated
network malfunction suspension control module, repair as
necessary

U0131- Lost Communication With The engine control Using the Jaguar Land Rover approved
00 Power Steering Control module has not diagnostic system, check power steering
Module - No sub type received the expected control module for DTCs and refer to
information CAN signal from the the relevant DTC index
power steering control Using the Jaguar Land Rover approved
module within the diagnostic system, carry out network
specified time interval integrity test. Refer to the electrical
CAN harness link circuit diagrams and check power
between engine steering control module power and
control module and ground circuits for open circuit. Check
power steering control CAN harness between engine control
module network module and power steering control
malfunction module, repair as necessary

U0133- Lost Communication With The engine control Using the Jaguar Land Rover approved
00 Active Roll Control module has not diagnostic system, check dynamic
Module - No sub type received the expected response control module for DTCs and
information CAN signal from the refer to the relevant DTC index
dynamic response Using the Jaguar Land Rover approved
control module within diagnostic system, carry out network
the specified time integrity test. Refer to the electrical
interval circuit diagrams and check dynamic
CAN harness link response control module power and
between engine ground circuits for open circuit. Check
control module and CAN harness between engine control
dynamic response module and dynamic response control
control module module, repair as necessary
network malfunction

U0138- Lost Communication with The engine control Using the Jaguar Land Rover approved
00 All Terrain Control module has not diagnostic system, check terrain
Module - No sub type received the expected response switchpack for DTCs and refer
information CAN signal from the to the relevant DTC index
terrain response Using the Jaguar Land Rover approved
switchpack within the diagnostic system, carry out network
specified time interval integrity test. Refer to the electrical
CAN harness link circuit diagrams and check terrain
between engine response switchpack power and ground
control module and circuits for open circuit. Check CAN
terrain response harness between engine control module
switchpack network and terrain response switchpack, repair
malfunction as necessary

U0140- Lost Communication With The engine control Using the Jaguar Land Rover approved
00 Body Control Module - No module has not diagnostic system, check central
sub type information received the expected junction box for DTCs and refer to the
CAN signal from the relevant DTC index
central junction box Using the Jaguar Land Rover approved
within the specified diagnostic system, carry out network
time interval integrity test. Refer to the electrical
CAN harness link circuit diagrams and check central
between engine junction box power and ground circuits
control module and for open circuit. Check CAN harness
central junction box between engine control module and
network malfunction central junction box, repair as necessary

U0146- Lost Communication With The engine control Using the Jaguar Land Rover approved
00 Gateway "A" - No sub type module has not diagnostic system, check gateway
information received the expected control module for DTCs and refer to
CAN signal from the the relevant DTC index
gateway control Using the Jaguar Land Rover approved
module within the diagnostic system, complete a CAN
specified time interval network integrity test
CAN harness link Refer to the electrical circuit diagrams
between engine and check gateway control module
control module and power and ground circuits for open
gateway control circuit
module network Check CAN harness between engine
malfunction control module and gateway control
module, repair as necessary

U0151- Lost Communication With The engine control Using the Jaguar Land Rover approved
00 Restraints Control Module module has not diagnostic system, check restraints
- No sub type information received the expected control module for DTCs and refer to
CAN signal from the the relevant DTC index
restraints control Using the Jaguar Land Rover approved
module within the diagnostic system, carry out network
specified time interval integrity test. Refer to the electrical
CAN harness link circuit diagrams and check restraints
between engine control module power and ground
control module and circuits for open circuit. Check CAN
restraints control harness between engine control module
module network and restraints control module, repair as
malfunction necessary

U0151- Lost Communication With The engine control Using the Jaguar Land Rover approved
08 Restraints Control Module module has not diagnostic system, check restraints
- Bus signal/message received the expected control module for DTCs and refer to
failures CAN signal from the the relevant DTC index
restraints control Using the Jaguar Land Rover approved
module within the diagnostic system, carry out network
specified time interval integrity test. Refer to the electrical
CAN harness link circuit diagrams and check restraints
between engine control module power and ground
control module and circuits for open circuit. Check CAN
restraints control harness between engine control module
module network and restraints control module, repair as
malfunction necessary

U0155- Lost Communication With The engine control Using the Jaguar Land Rover approved
00 Instrument Panel Cluster module has not diagnostic system, check instrument
Control Module - No sub received the expected cluster for DTCs and refer to the
type information CAN signal from the relevant DTC index
instrument cluster Using the Jaguar Land Rover approved
within the specified diagnostic system, carry out network
time interval integrity test. Refer to the electrical
CAN harness link circuit diagrams and check instrument
between engine cluster power and ground circuits for
control module and open circuit. Check CAN harness
instrument cluster between engine control module and
network malfunction instrument cluster, repair as necessary

U0159- Lost Communication With The engine control Using the Jaguar Land Rover approved
00 Parking Assist Control module has not diagnostic system, check park distance
Module "A" - No sub type received the expected control module for DTCs and refer to
information CAN signal from the the relevant DTC index
park distance control Using the Jaguar Land Rover approved
module within the diagnostic system, complete a CAN
specified time interval network integrity test
CAN harness link Refer to the electrical circuit diagrams
between engine and check park distance control module
control module and power and ground circuits for open
park distance control circuit
module network Check CAN harness between engine
malfunction control module and park distance
control module, repair as necessary

U0164- Lost Communication With Power distribution This DTC is set if the engine control
00 HVAC Control Module - system failure - Fuse module loses communication with the
No sub type information failure HVAC Control Module. Check the
CAN network failure HVAC Control Module for DTCs and
HVAC Control refer to the relevant DTC index
Module failure Refer to the electrical circuit diagrams
and check the power supply and ground
connections to the HVAC Control
Module
Using the Jaguar Land Rover approved
diagnostic system, complete a CAN
network integrity test. Refer to electrical
circuit diagrams and check CAN circuits
if required. Repair wiring harness as
required
Check and install new HVAC Control
Module

U0167- Lost Communication With Engine control module Check the electric steering column lock
00 Vehicle Immobilizer identity transfer failed for DTCs and refer to the relevant DTC
Control Module - No sub index. Refer to the electrical circuit
type information diagrams and check the power supply
and ground connections to the electric
steering column lock. Using the Jaguar
Land Rover approved diagnostic
system, complete a CAN network
integrity test. Refer to electrical circuit
diagrams and check CAN circuits if
required. Repair wiring harness as
required
Check and install new electric steering
column lock

U0300- Internal Control Module CAN network failure Using the Jaguar Land Rover approved
00 Software Incompatibility - Central junction box diagnostic system, complete a CAN
No sub type information failure network integrity test. Refer to electrical
Car configuration file circuit diagrams and check CAN circuits
incorrect if required. Repair harness as required
Car configuration signal not received.
Check central junction box for DTCs
and refer to the relevant DTC index
Using the Jaguar Land Rover approved
diagnostic system, check and up-date
the car configuration file as required

U0402- Invalid Data Received CAN network failure Check transmission control module for
00 from TCM - No sub type Implausible CAN data related DTCs and refer to relevant DTC
information received from index
transmission control Using the Jaguar Land Rover approved
module diagnostic system, complete a CAN
network integrity test. Refer to electrical
circuit diagrams and check CAN circuits
if required. Repair harness as required

U0402- Invalid Data Received CAN network failure Check transmission control module for
83 from TCM - Value of Implausible CAN data related DTCs and refer to relevant DTC
signal protection received from index
calculation incorrect transmission control Using the Jaguar Land Rover approved
module diagnostic system, complete a CAN
network integrity test. Refer to electrical
circuit diagrams and check CAN circuits
if required. Repair harness as required

U0404- Invalid Data Received CAN network failure Check transmission control switch for
68 from Gear Shift Control Implausible CAN data related DTCs and refer to relevant DTC
Module A - Event received from index
information transmission control Using the Jaguar Land Rover approved
switch diagnostic system, complete a CAN
network integrity test. Refer to electrical
circuit diagrams and check CAN circuits
if required. Repair harness as required

U0405- Invalid Data Received Speed control system Check speed control module for related
68 From Cruise Control failure DTCs and refer to relevant DTC index
Module - Event Refer to the electrical circuit diagrams
information and check the power supply and ground
connections to the speed control module
Using the Jaguar Land Rover approved
diagnostic system, complete a CAN
network integrity test. Refer to electrical
circuit diagrams and check CAN circuits
if required. Repair harness as required
Check and install new speed control
module

U0405- Invalid Data Received Speed control system Check speed control buttons are not
82 From Cruise Control failure jammed/contaminated/damaged. Check
Module - Alive/sequence CAN network failure speed control module for related DTCs
counter incorrect /not Harness failure - and refer to the relevant DTC index
updated Speed control module Using the Jaguar Land Rover approved
power supply or diagnostic system, complete a CAN
ground failure network integrity test. Refer to electrical
circuit diagrams and check CAN circuits
if required. Repair harness as required
Refer to the electrical circuit diagrams
and check the power supply and ground
connections to the speed control module
Check and install new speed control
module

U0405- Invalid Data Received Speed control system Check speed control module for related
84 From Cruise Control failure DTCs and refer to relevant DTC index
Module - Signal below Refer to the electrical circuit diagrams
allowable range and check the power supply and ground
connections to the speed control module
Using the Jaguar Land Rover approved
diagnostic system, complete a CAN
network integrity test. Refer to electrical
circuit diagrams and check CAN circuits
if required. Repair harness as required
Check and install new speed control
module

U0405- Invalid Data Received Speed control system Check speed control buttons are not
86 From Cruise Control failure jammed/contaminated/damaged. Check
Module - Signal invalid speed control module for related DTCs
and refer to the relevant DTC index

U0407- Invalid Data Received This DTC is set when Check the correct glow plug control
00 From Glow Plug Control the glow plug control module is installed to the vehicle
Module - No sub type module does not
information match what is
expected by the engine
control module.
Detection of the
coding word is
complete when 2 of 3
coding words match.
This process is a one
time operation and
will be completed
during assembly of the
vehicle

U0407- Invalid Data Received Glow plug control Refer to electrical circuit diagrams and
81 From Glow Plug Control system failure check the power supply and ground
Module - Invalid serial connections to the glow plug control
data received module. Check the diagnostic circuit
between the engine control module and
the glow plug control module for short
circuit to power, short circuit to ground,
open circuits. Clear the DTC and retest
Check and install new glow plug control
module

U0415- Invalid Data Received Signal error for Using the Jaguar Land Rover approved
68 From Anti-Lock Brake vehicle speed over diagnostic system, check anti-lock brake
System (ABS) Control CAN system control module for DTCs and
Module - Event refer to the relevant DTC index
information
U0416- Invalid Data Received Anti-lock brake Using the Jaguar Land Rover approved
46 From Vehicle Dynamics system failure diagnostic system, check anti-lock brake
Control Module - system control module for DTCs and
Calibration/parameter refer to the relevant DTC index
memory failure
U0416- Invalid Data Received The engine control Using the Jaguar Land Rover approved
68 From Vehicle Dynamics module has received diagnostic system, check anti-lock brake
Control Module - Event the default brake system control module for DTCs and
information pressure signal value refer to the relevant DTC index
over CAN from the Using the Jaguar Land Rover approved
anti-lock brake system diagnostic system, carry out network
control module for a integrity test. Refer to the electrical
specified time interval circuit diagrams and check anti-lock
Anti-lock brake brake system control module power and
system failure ground circuits for open circuit. Check
CAN harness link CAN harness between engine control
between engine module and anti-lock brake system
control module and control module, repair as necessary
anti-lock brake system
control module
network malfunction

U0416- Invalid Data Received Difference between Check the anti-lock brake system control
92 From Vehicle Dynamics anti-lock brake system module for DTCs and refer to the relevant
Control Module - speed signal value and DTC index
Performance or incorrect instrument cluster
operation speed value at low
vehicle speeds

U0422- Invalid Data Received The engine control Using the Jaguar Land Rover approved
00 From Body Control module has not diagnostic system, check central
Module - No sub type received the expected junction box for DTCs and refer to the
information CAN signal from the relevant DTC index
central junction box Using the Jaguar Land Rover approved
within the specified diagnostic system, complete a CAN
time interval network integrity test
CAN harness link Refer to the electrical circuit diagrams
between engine and check central junction box power
control module and and ground circuits for open circuit
central junction box Check CAN harness between engine
network malfunction control module and central junction box,
repair as necessary

U0424- Invalid Data Received The engine control Using the Jaguar Land Rover approved
00 From HVAC Control module has not diagnostic system, check HVAC
Module - No sub type received the expected Control Module for DTCs and refer to
information CAN signal from the the relevant DTC index
HVAC Control Using the Jaguar Land Rover approved
Module within the diagnostic system, complete a CAN
specified time interval network integrity test
CAN harness link Refer to the electrical circuit diagrams
between engine and check HVAC Control Module
control module and power and ground circuits for open
HVAC Control circuit
Module network Check CAN harness between engine
malfunction control module and HVAC Control
Module, repair as necessary

U0424- Invalid Data Received Power distribution This DTC is set if the engine control
68 From HVAC Control system failure - Fuse module loses communication with the
Module - Event failure HVAC Control Module. Check the
information CAN network failure HVAC Control Module for DTCs and
HVAC Control refer to the relevant DTC index
Module failure Refer to the electrical circuit diagrams
and check the power supply and ground
connections to the HVAC Control
Module
Using the Jaguar Land Rover approved
diagnostic system, complete a CAN
network integrity test. Refer to electrical
circuit diagrams and check CAN circuits
if required. Repair wiring harness as
required
Check and install new HVAC Control
Module as required

U0426- Invalid Data Received Electric steering Using the Jaguar Land Rover approved
00 From Vehicle Immobilizer column lock has diagnostic system, complete a CAN
Control Module - No sub received an invalid network integrity test. Refer to electrical
type information identity response circuit diagrams and check CAN circuits
Module substituted if required. Repair harness as required.
Using the Jaguar Land Rover approved
diagnostic system, check and up-date
the car configuration file as required
Ensure all modules installed in the
vehicle which store vehicle identity are
valid for this vehicle and are not
substitutes from a donor vehicle

U0447- Invalid Data Received NOTE: Check the gateway module for DTCs
00 From Gateway "A" - No and refer to the relevant DTC index
sub type information Monitor description. Engine Inspect connectors for signs of water
control module has been ingress and pins for damage and/or
informed of a failure within corrosion
the dual battery system Refer to the electrical circuit diagrams
and check connections are secure and
Connector is wiring integrity
disconnected, Using the Jaguar Land Rover approved
connector pin is diagnostic system, clear all stored DTCs
backed out, connector using the ‘Diagnosis Menu’ tab and
pin corrosion retest
Harness failure -
Wiring integrity dual
battery system
Harness failure -
Wiring integrity
gateway module

U0452- Invalid Data Received NOTE: Check the restraints control module for
00 From Restraints Control DTCs and refer to the relevant DTC
Module - No sub type Monitor description. Engine index
information control module has been Inspect connectors for signs of water
informed of a failure within ingress and pins for damage and/or
the seat belt sensor corrosion
Refer to the electrical circuit diagrams
Connector is and check connections are secure and
disconnected, wiring integrity
connector pin is Using the Jaguar Land Rover approved
backed out, connector diagnostic system, clear all stored DTCs
pin corrosion using the ‘Diagnosis Menu’ tab and
Harness failure - retest
Wiring integrity seat
belt sensor
Harness failure -
Wiring integrity
gateway module

U0A1A- LIN Bus "A" - Missing Generator LIN bus Refer to the electrical circuit diagrams
87 message communication circuit and check the generator LIN bus circuit,
failure for short circuit to power, short circuit
to ground, open circuit. Repair harness
as required. Using the Jaguar Land
Rover approved diagnostic system, clear
all stored DTCs using the ‘Diagnosis
Menu’ tab and retest

U1A14- CAN Initialization Failure Harness failure - CAN Using the Jaguar Land Rover approved
00 - No sub type information circuit failure diagnostic system, complete a CAN
network integrity test. Refer to electrical
circuit diagrams and check CAN circuits
if required. Repair wiring harness as
required

U2005- Vehicle Speed - Signal Anti-lock brake This DTC is set when the engine control
64 plausibility failure system failure module has recognized a vehicle speed
signal plausibility failure. Check the
anti-lock brake system module for
related DTCs and refer to the relevant
DTC index. Check the instrument
cluster for related DTCs and refer to the
relevant DTC index. Using the Jaguar
Land Rover approved diagnostic
system, complete a CAN network
integrity test. Refer to electrical circuit
diagrams and check CAN circuits if
required. Repair wiring harness as
required

U2005- Vehicle Speed - Below Anti-lock brake This DTC is set when the engine control
84 allowable range system failure module has recognized a vehicle speed
signal which is below the allowable
range. Check the anti-lock brake system
control module for related DTCs and
refer to the relevant DTC index. Check
the instrument cluster for related DTCs
and refer to the relevant DTC index.
Using the Jaguar Land Rover approved
diagnostic system, complete a CAN
network integrity test. Refer to electrical
circuit diagrams and check CAN circuits
if required. Repair wiring harness as
required

U2005- Vehicle Speed - Above Anti-lock brake This DTC is set when the engine control
85 allowable range system failure module has recognized a vehicle speed
signal which is above the allowable
range. Check the anti-lock brake system
control module for related DTCs and
refer to the relevant DTC index. Check
the instrument cluster for related DTCs
and refer to the relevant DTC index.
Using the Jaguar Land Rover approved
diagnostic system, complete a CAN
network integrity test. Refer to electrical
circuit diagrams and check CAN circuits
if required. Repair wiring harness as
required

U2108- Adaptive Cruise Control - Adaptive speed Check adaptive speed control module
00 No sub type information control system failure for DTCs and refer to the relevant DTC
- Error indicating index. Using the Jaguar Land Rover
adaptive speed control approved diagnostic system, complete a
failure flag set CAN network integrity test. Refer to
electrical circuit diagrams and check
CAN circuits if required. Repair wiring
harness as required

U2108- Adaptive Cruise Control - The engine control Check adaptive speed control module
24 Signal stuck high module measures a for DTCs and refer to the relevant DTC
signal that remains index. Using the Jaguar Land Rover
high when transitions approved diagnostic system, complete a
are expected CAN network integrity test. Refer to
Adaptive speed electrical circuit diagrams and check
control system failure CAN circuits if required. Repair wiring
- Adaptive speed harness as required
control follow speed
error

U2108- Adaptive Cruise Control - Adaptive speed Check adaptive speed control module
64 Signal plausibility failure control system failure for DTCs and refer to the relevant DTC
- Adaptive speed index. Using the Jaguar Land Rover
control follow speed approved diagnostic system, complete a
range error CAN network integrity test. Refer to
electrical circuit diagrams and check
CAN circuits if required. Repair wiring
harness as required

U2108- Adaptive Cruise Control - Adaptive speed Check adaptive speed control module
68 Event information control system failure for DTCs and refer to the relevant DTC
- Error indicating index. Using the Jaguar Land Rover
adaptive speed control approved diagnostic system, complete a
follow speed check CAN network integrity test. Refer to
when stationary electrical circuit diagrams and check
CAN circuits if required. Repair wiring
harness as required

U2108- Adaptive Cruise Control - Adaptive speed Check adaptive speed control module
86 Signal invalid control system failure for DTCs and refer to the relevant DTC
- Error when invalid index. Using the Jaguar Land Rover
adaptive speed control approved diagnostic system, complete a
resume requests are CAN network integrity test. Refer to
present electrical circuit diagrams and check
CAN circuits if required. Repair wiring
harness as required
Published: 17-Apr-2014

2012.0 XF (X250), 100-00

General Information

Diagnostic Trouble Code Index - DTC: Front Seat


Climate Control Module (DCSM) (G1426789)
DESCRIPTION AND OPERATION
Front Seat Climate Control Module (DCSM)
CAUTION:

Diagnosis by substitution from a donor vehicle is NOT acceptable. Substitution of control modules does not
guarantee confirmation of a fault, and may also cause additional faults in the vehicle being tested and/or the donor
vehicle

NOTES:

If the control module or a component is suspect and the vehicle remains under manufacturer warranty, refer to
the warranty policy and procedures manual, or determine if any prior approval programme is in operation,
prior to the installation of a new module/component

Generic scan tools may not read the codes listed, or may read only 5-digit codes. Match the 5 digits from the
scan tool to the first 5 digits of the 7-digit code listed to identify the fault (the last 2 digits give extra
information read by the manufacturer-approved diagnostic system)

When performing voltage or resistance tests, always use a digital multimeter accurate to three decimal places
and with a current calibration certificate. When testing resistance, always take the resistance of the digital
multimeter leads into account

Check and rectify basic faults before beginning diagnostic routines involving pinpoint tests

Inspect connectors for signs of water ingress, and pins for damage and/or corrosion

If diagnostic trouble codes are recorded and, after performing the pinpoint tests, a fault is not present, an
intermittent concern may be the cause. Always check for loose connections and corroded terminals

Where an 'on demand self-test' is referred to, this can be accessed via the 'diagnostic trouble code monitor' tab
on the manufacturers approved diagnostic system

The table below lists all diagnostic trouble codes (DTCs) that could be logged in the seat climate control module, for
additional diagnosis and testing information refer to the relevant diagnosis and testing section. For additional
information, refer to: Seats (501-10 Seating, Diagnosis and Testing).

DTC Description Possible Causes Action


B10B9- Blower Control - Connectors Check for any disconnected connectors or
13 Circuit open disconnected or damaged connector pins
connector pin damage Carry out on demand self test using
Seat blower left circuit manufacturer approved diagnostic system to
- Open circuit confirm the fault is present
Blower motor Refer to the electrical circuit diagrams and
assembly - Short check the front seat climate control module -
circuit to ground Circuit reference LH_FANS_RTN, Circuit
Front seat climate reference LH_FANS_PWR - For open circuit.
control module failure Repair circuit as required, clear DTC and retest
Carry out on demand self test using
manufacturer approved diagnostic system to
confirm rectification. Alternatively, carry out
any pinpoint tests associated with this DTC
using the manufacturer approved diagnostic
system

B10B9- Blower Control - Mechanical restriction Check for mechanical restriction or debris in
4B Over temperature in blower motor seat blower
assembly Carry out on demand self test using
Seat blower left circuit manufacturer approved diagnostic system to
- Short circuit to confirm the fault is present
ground Refer to the electrical circuit diagrams and
Blower motor check the front seat climate control module -
assembly - Short Circuit reference LH_FANS_RTN, Circuit
circuit to ground reference LH_FANS_PWR - For short circuit
Front seat climate to ground. Repair circuit as required, clear DTC
control module failure and retest
Carry out on demand self test using
manufacturer approved diagnostic system to
confirm rectification. Alternatively, carry out
any pinpoint tests associated with this DTC
using the manufacturer approved diagnostic
system

B1157- Blower Control "B" Connectors Check for any disconnected connectors or
13 - Circuit open disconnected or damaged connector pins
connector pin damage Carry out on demand self test using
Seat blower right manufacturer approved diagnostic system to
circuit - Open circuit confirm the fault is present
Blower motor Refer to the electrical circuit diagrams and
assembly - Open check the front seat climate control module -
circuit Circuit reference RH_FANS_RTN, Circuit
Front seat climate reference RH_FANS_PWR - For open circuit.
control module failure Repair circuit as required, clear DTC and retest
Carry out on demand self test using
manufacturer approved diagnostic system to
confirm rectification. Alternatively, carry out
any pinpoint tests associated with this DTC
using the manufacturer approved diagnostic
system

B1157- Blower Control "B" Mechanical restriction Check for mechanical restriction or debris in
4B - Over temperature in blower motor seat blower
assembly Carry out on demand self test using
Seat blower right manufacturer approved diagnostic system to
circuit - Short circuit to confirm the fault is present
ground Refer to the electrical circuit diagrams and
Blower motor check the front seat climate control module -
assembly - Short Circuit reference RH_FANS_RTN, Circuit
circuit to ground reference RH_FANS_PWR - For short circuit
Front seat climate to ground. Repair circuit as required, clear DTC
control module failure and retest
Carry out on demand self test using
manufacturer approved diagnostic system to
confirm rectification. Alternatively, carry out
any pinpoint tests associated with this DTC
using the manufacturer approved diagnostic
system

B120E- Right Thermal Connectors Check for any disconnected connectors or


13 Electric Device disconnected or damaged connector pins
Control - Circuit connector pin damage Carry out on demand self test using
open Seat backrest thermal manufacturer approved diagnostic system to
electric device right confirm the fault is present
circuit - Open circuit Refer to the electrical circuit diagrams and
Seat cushion thermal check the front seat climate control module -
electric device right Circuit reference RH_SEAT_BACK_TED+,
circuit - Open circuit Circuit reference RH_SEAT_BACK_TED- -
Front seat climate For open circuit. Repair circuit as required,
control module failure clear DTC and retest
Refer to the electrical circuit diagrams and
check the front seat climate control module -
Circuit reference RH_CUSHION_TED+,
Circuit reference RH_CUSHION_TED- - For
open circuit. Repair circuit as required, clear
DTC and retest
Carry out on demand self test using
manufacturer approved diagnostic system to
confirm rectification. Alternatively, carry out
any pinpoint tests associated with this DTC
using the manufacturer approved diagnostic
system

B120E- Right Thermal Seat backrest thermal Carry out on demand self test using
19 Electric Device electric device right manufacturer approved diagnostic system to
Control - Circuit circuit - Short circuit to confirm the fault is present
current above ground Refer to the electrical circuit diagrams and
threshold Seat cushion thermal check the front seat climate control module -
electric device right Circuit reference RH_SEAT_BACK_TED+,
circuit - Short circuit to Circuit reference RH_SEAT_BACK_TED- -
ground For short circuit to ground. Repair circuit as
Front seat climate required, clear DTC and retest
control module failure Refer to the electrical circuit diagrams and
check the front seat climate control module -
Circuit reference RH_CUSHION_TED+,
Circuit reference RH_CUSHION_TED- - For
short circuit to ground. Repair circuit as
required, clear DTC and retest
Carry out on demand self test using
manufacturer approved diagnostic system to
confirm rectification. Alternatively, carry out
any pinpoint tests associated with this DTC
using the manufacturer approved diagnostic
system

B120E- Right Thermal Restriction in thermal Check for blockage or restriction in thermal
4B Electric Device electric device air path electric device air path
Control - Over Seat backrest thermal Carry out on demand self test using
temperature electric device right manufacturer approved diagnostic system to
circuit - Short circuit to confirm the fault is present
ground Refer to the electrical circuit diagrams and
Seat cushion thermal check the front seat climate control module -
electric device right Circuit reference RH_SEAT_BACK_TED+,
circuit - Short circuit to Circuit reference RH_SEAT_BACK_TED- -
ground For short circuit to ground. Repair circuit as
Front seat climate required, clear DTC and retest
control module failure Refer to the electrical circuit diagrams and
check the front seat climate control module -
Circuit reference RH_CUSHION_TED+,
Circuit reference RH_CUSHION_TED- - For
short circuit to ground. Repair circuit as
required, clear DTC and retest
Carry out on demand self test using
manufacturer approved diagnostic system to
confirm rectification. Alternatively, carry out
any pinpoint tests associated with this DTC
using the manufacturer approved diagnostic
system

B120F- Left Seat Cushion - Blocked or restricted Check for blockage or restriction in thermal
98 Component or thermal electric device electric device fan exhaust vent
system over fan exhaust vent Check for restricted thermal electric device fan
temperature Restricted thermal movement
electric device fan Carry out on demand self test using
movement manufacturer approved diagnostic system to
confirm rectification. Alternatively, carry out
any pinpoint tests associated with this DTC
using the manufacturer approved diagnostic
system

B1223- Right Seat Cushion Connectors Check for any disconnected connectors or
13 Temperature Sensor disconnected or damaged connector pins
- Circuit open connector pin damage Carry out on demand self test using
Seat cushion manufacturer approved diagnostic system to
temperature sensor confirm the fault is present
right circuit - Open Refer to the electrical circuit diagrams and
circuit check the front seat climate control module -
Front seat climate Circuit reference RH_CUSHION_SENSOR,
control module failure Circuit reference
RH_CUSHION_SENSOR_RTN - For open
circuit. Repair circuit as required, clear DTC
and retest
Carry out on demand self test using
manufacturer approved diagnostic system to
confirm rectification. Alternatively, carry out
any pinpoint tests associated with this DTC
using the manufacturer approved diagnostic
system

B1224- Left Thermal Connectors Check for any disconnected connectors or


13 Electric Device disconnected or damaged connector pins
Control - Circuit connector pin damage Carry out on demand self test using
open Seat backrest thermal manufacturer approved diagnostic system to
electric device left confirm the fault is present
circuit - Open circuit Refer to the electrical circuit diagrams and
Seat cushion thermal check the front seat climate control module -
electric device left Circuit reference LH_SEAT_BACK_TED+,
circuit - Open circuit Circuit reference LH_SEAT_BACK_TED- -
Front seat climate For short circuit to ground. Repair circuit as
control module failure required, clear DTC and retest
Refer to the electrical circuit diagrams and
check the front seat climate control module -
Circuit reference LH_CUSHION_TED+,
Circuit reference LH_CUSHION_TED- - For
short circuit to ground. Repair circuit as
required, clear DTC and retest
Carry out on demand self test using
manufacturer approved diagnostic system to
confirm rectification. Alternatively, carry out
any pinpoint tests associated with this DTC
using the manufacturer approved diagnostic
system

B1224- Left Thermal Seat backrest thermal Carry out on demand self test using
19 Electric Device electric device left manufacturer approved diagnostic system to
Control - Circuit circuit - Short circuit to confirm the fault is present
current above ground Refer to the electrical circuit diagrams and
threshold Seat cushion thermal check the front seat climate control module -
electric device left Circuit reference LH_SEAT_BACK_TED+,
circuit - Short circuit to Circuit reference LH_SEAT_BACK_TED- -
ground For short circuit to ground. Repair circuit as
Front seat climate required, clear DTC and retest
control module failure Refer to the electrical circuit diagrams and
check the front seat climate control module -
Circuit reference LH_CUSHION_TED+,
Circuit reference LH_CUSHION_TED- - For
short circuit to ground. Repair circuit as
required, clear DTC and retest
Carry out on demand self test using
manufacturer approved diagnostic system to
confirm rectification. Alternatively, carry out
any pinpoint tests associated with this DTC
using the manufacturer approved diagnostic
system

B1224- Left Thermal Restriction in thermal Check for blockage or restriction in thermal
4B Electric Device electric device air path electric device air path
Control - Over Seat backrest thermal Carry out on demand self test using
temperature electric device left manufacturer approved diagnostic system to
circuit - Short circuit to confirm the fault is present
ground Refer to the electrical circuit diagrams and
Seat cushion thermal check the front seat climate control module -
electric device left Circuit reference LH_SEAT_BACK_TED+,
circuit - Short circuit to Circuit reference LH_SEAT_BACK_TED- -
ground For short circuit to ground. Repair circuit as
Front seat climate required, clear DTC and retest
control module failure Refer to the electrical circuit diagrams and
check the front seat climate control module -
Circuit reference LH_CUSHION_TED+,
Circuit reference LH_CUSHION_TED- - For
short circuit to ground. Repair circuit as
required, clear DTC and retest
Carry out on demand self test using
manufacturer approved diagnostic system to
confirm rectification. Alternatively, carry out
any pinpoint tests associated with this DTC
using the manufacturer approved diagnostic
system

B1225- Right Seat Back Connectors Check for any disconnected connectors or
13 Temperature Sensor disconnected or damaged connector pins
- Circuit open connector pin damage Carry out on demand self test using
Seat backrest manufacturer approved diagnostic system to
temperature sensor confirm the fault is present
right circuit - Open Refer to the electrical circuit diagrams and
circuit check the front seat climate control module -
Front seat climate Circuit reference
control module failure RH_SEAT_BACK_SENSOR, Circuit
reference RH_SEAT_BACK_SENSOR_RTN -
For open circuit. Repair circuit as required,
clear DTC and retest
Carry out on demand self test using
manufacturer approved diagnostic system to
confirm rectification. Alternatively, carry out
any pinpoint tests associated with this DTC
using the manufacturer approved diagnostic
system

B1229- Left Seat Back Connectors Check for any disconnected connectors or
13 Temperature Sensor disconnected or damaged connector pins
- Circuit open connector pin damage Carry out on demand self test using
Seat backrest manufacturer approved diagnostic system to
temperature sensor left confirm the fault is present
circuit - Open circuit Refer to the electrical circuit diagrams and
Front seat climate check the front seat climate control module -
control module failure Circuit reference
LH_SEAT_BACK_SENSOR, Circuit
reference LH_SEAT_BACK_SENSOR_RTN -
For open circuit. Repair circuit as required,
clear DTC and retest
Carry out on demand self test using
manufacturer approved diagnostic system to
confirm rectification. Alternatively, carry out
any pinpoint tests associated with this DTC
using the manufacturer approved diagnostic
system

B122A- Right Seat Cushion Seat cushion blower Carry out on demand self test using
11 Blower Speed speed right circuit - manufacturer approved diagnostic system to
Sensor - Circuit Short circuit to ground confirm the fault is present
short to ground Blower motor Refer to the electrical circuit diagrams and
assembly - Short check the front seat climate control module -
circuit to ground Circuit reference
Front seat climate RH_CUSHION_FAN_SPEED - For short
control module failure circuit to ground. Repair circuit as required,
clear DTC and retest
Carry out on demand self test using
manufacturer approved diagnostic system to
confirm rectification. Alternatively, carry out
any pinpoint tests associated with this DTC
using the manufacturer approved diagnostic
system
B122A- Right Seat Cushion Seat cushion blower Carry out on demand self test using
12 Blower Speed speed right circuit - manufacturer approved diagnostic system to
Sensor - Circuit Short circuit to power confirm the fault is present
short to battery Blower motor Refer to the electrical circuit diagrams and
assembly - Short check the front seat climate control module -
circuit to power Circuit reference
Front seat climate RH_CUSHION_FAN_SPEED - For short
control module failure circuit to power. Repair circuit as required,
clear DTC and retest
Carry out on demand self test using
manufacturer approved diagnostic system to
confirm rectification. Alternatively, carry out
any pinpoint tests associated with this DTC
using the manufacturer approved diagnostic
system

B122B- Right Seat Back Seat backrest blower Carry out on demand self test using
11 Blower Speed speed right circuit - manufacturer approved diagnostic system to
Sensor - Circuit Short circuit to ground confirm the fault is present
short to ground Blower motor Refer to the electrical circuit diagrams and
assembly - Short check the front seat climate control module -
circuit to ground Circuit reference
Front seat climate RH_SEAT_BACK_FAN_SPEED - For short
control module failure circuit to ground. Repair circuit as required,
clear DTC and retest
Carry out on demand self test using
manufacturer approved diagnostic system to
confirm rectification. Alternatively, carry out
any pinpoint tests associated with this DTC
using the manufacturer approved diagnostic
system

B122B- Right Seat Back Seat backrest blower Carry out on demand self test using
12 Blower Speed speed right circuit - manufacturer approved diagnostic system to
Sensor - Circuit Short circuit to power confirm the fault is present
short to battery Blower motor Refer to the electrical circuit diagrams and
assembly - Short check the front seat climate control module -
circuit to power Circuit reference
Front seat climate RH_SEAT_BACK_FAN_SPEED - For short
control module failure circuit to power. Repair circuit as required,
clear DTC and retest
Carry out on demand self test using
manufacturer approved diagnostic system to
confirm rectification. Alternatively, carry out
any pinpoint tests associated with this DTC
using the manufacturer approved diagnostic
system

B122C- Left Seat Cushion Seat cushion blower Carry out on demand self test using
11 Blower Speed speed left circuit - manufacturer approved diagnostic system to
Sensor - Circuit Short circuit to ground confirm the fault is present
short to ground Blower motor Refer to the electrical circuit diagrams and
assembly - Short check the front seat climate control module -
circuit to ground Circuit reference
Front seat climate LH_CUSHION_FAN_SPEED - For short
control module failure circuit to ground. Repair circuit as required,
clear DTC and retest
Carry out on demand self test using
manufacturer approved diagnostic system to
confirm rectification. Alternatively, carry out
any pinpoint tests associated with this DTC
using the manufacturer approved diagnostic
system

B122C- Left Seat Cushion Seat cushion blower Carry out on demand self test using
12 Blower Speed speed left circuit - manufacturer approved diagnostic system to
Sensor - Circuit Short circuit to power confirm the fault is present
short to battery Blower motor Refer to the electrical circuit diagrams and
assembly - Short check the front seat climate control module -
circuit to power Circuit reference
Front seat climate LH_CUSHION_FAN_SPEED - For short
control module failure circuit to power. Repair circuit as required,
clear DTC and retest
Carry out on demand self test using
manufacturer approved diagnostic system to
confirm rectification. Alternatively, carry out
any pinpoint tests associated with this DTC
using the manufacturer approved diagnostic
system

B122D- Left Seat Back Seat backrest blower Carry out on demand self test using
11 Blower Speed speed left circuit - manufacturer approved diagnostic system to
Sensor - Circuit Short circuit to ground confirm the fault is present
short to ground Blower motor Refer to the electrical circuit diagrams and
assembly - Short check the front seat climate control module -
circuit to ground Circuit reference
Front seat climate LH_SEAT_BACK_FAN_SPEED - For short
control module failure circuit to ground. Repair circuit as required,
clear DTC and retest
Carry out on demand self test using
manufacturer approved diagnostic system to
confirm rectification. Alternatively, carry out
any pinpoint tests associated with this DTC
using the manufacturer approved diagnostic
system

B122D- Left Seat Back Seat backrest blower Carry out on demand self test using
12 Blower Speed speed left circuit - manufacturer approved diagnostic system to
Sensor - Circuit Short circuit to power confirm the fault is present
short to battery Blower motor Refer to the electrical circuit diagrams and
assembly - Short check the front seat climate control module -
circuit to power Circuit reference
Front seat climate LH_SEAT_BACK_FAN_SPEED - For short
control module failure circuit to power. Repair circuit as required,
clear DTC and retest
Carry out on demand self test using
manufacturer approved diagnostic system to
confirm rectification. Alternatively, carry out
any pinpoint tests associated with this DTC
using the manufacturer approved diagnostic
system
B122E- Right Seat Cushion Blocked or restricted Check for blockage or restriction in thermal
98 - Component or thermal electric device electric device fan exhaust vent
system over fan exhaust vent Check for restricted thermal electric device fan
temperature Restricted thermal movement
electric device fan Carry out on demand self test using
movement manufacturer approved diagnostic system to
confirm rectification. Alternatively, carry out
any pinpoint tests associated with this DTC
using the manufacturer approved diagnostic
system

B122F- Right Seat Back - Blocked or restricted Check for blockage or restriction in thermal
98 Component or thermal electric device electric device fan exhaust vent
system over fan exhaust vent Check for restricted thermal electric device fan
temperature Restricted thermal movement
electric device fan Carry out on demand self test using
movement manufacturer approved diagnostic system to
confirm rectification. Alternatively, carry out
any pinpoint tests associated with this DTC
using the manufacturer approved diagnostic
system

B1230- Left Seat Back - Blocked or restricted Check for blockage or restriction in thermal
98 Component or thermal electric device electric device fan exhaust vent
system over fan exhaust vent Check for restricted thermal electric device fan
temperature Restricted thermal movement
electric device fan Carry out on demand self test using
movement manufacturer approved diagnostic system to
confirm rectification. Alternatively, carry out
any pinpoint tests associated with this DTC
using the manufacturer approved diagnostic
system

B1231- Right Seat - Fluid Seat backrest assembly Check for blockage or restriction in seat
7A leak or seal failure - Air path leaking backrest/seat cushion thermal electric device
Seat cushion assembly fan ducts
- Air path leaking Check seat backrest/seat cushion thermal
Seat assembly electric device fan exhaust vent is clear
damaged Carry out on demand self test using
manufacturer approved diagnostic system to
confirm rectification. Alternatively, carry out
any pinpoint tests associated with this DTC
using the manufacturer approved diagnostic
system

B1232- Left Seat - Fluid Seat backrest assembly Check for blockage or restriction in seat
7A leak or seal failure - Air path leaking backrest/seat cushion thermal electric device
Seat cushion assembly fan ducts
- Air path leaking Check seat backrest/seat cushion thermal
Seat assembly electric device fan exhaust vent is clear
damaged Carry out on demand self test using
manufacturer approved diagnostic system to
confirm rectification. Alternatively, carry out
any pinpoint tests associated with this DTC
using the manufacturer approved diagnostic
system
B1235- Left Seat Cushion Connectors Check for any disconnected connectors or
13 Temperature Sensor disconnected or damaged connector pins
- Circuit open connector pin damage Carry out on demand self test using
Seat cushion manufacturer approved diagnostic system to
temperature sensor left confirm the fault is present
circuit - Open circuit Refer to the electrical circuit diagrams and
Front seat climate check the front seat climate control module -
control module failure Circuit reference LH_CUSHION_SENSOR,
Circuit reference
LH_CUSHION_SENSOR_RTN - For open
circuit. Repair circuit as required, clear DTC
and retest
Carry out on demand self test using
manufacturer approved diagnostic system to
confirm rectification. Alternatively, carry out
any pinpoint tests associated with this DTC
using the manufacturer approved diagnostic
system

U0010- Medium Speed Medium speed CAN Refer to the electrical circuit diagrams and
88 CAN communication - Bus check the power and ground connections to the
Communication off module
Bus - Bus off Using the manufacturer approved diagnostic
system, complete a CAN network integrity test
Carry out on demand self test using
manufacturer approved diagnostic system to
confirm rectification

U0140- Lost Lost communication NOTE:


00 Communication with central junction
With Body Control box This DTC may be stored even though no fault
Module - No sub condition is present and should be ignored unless the
type information customer has reported a climate seat concern. Clear
the DTC and retest. Verify the customer concern prior
to diagnosis

Refer to the electrical circuit diagrams and


check the power and ground connections to the
module
Using the manufacturer approved diagnostic
system, complete a CAN network integrity test
Refer to the electrical circuit diagrams and
check the CAN network between the front seat
climate control module and central junction
box
Carry out on demand self test using
manufacturer approved diagnostic system to
confirm rectification

U0142- Lost Lost communication Refer to the electrical circuit diagrams and
00 Communication with rear junction box check the power and ground connections to the
With Body Control module
Module "B" - No Using the manufacturer approved diagnostic
sub type system, complete a CAN network integrity test
information Refer to the electrical circuit diagrams and
check the CAN network between the front seat
climate control module and rear junction box
Carry out on demand self test using
manufacturer approved diagnostic system to
confirm rectification

U0155- Lost Lost communication Refer to the electrical circuit diagrams and
00 Communication with instrument cluster check the power and ground connections to the
With Instrument module
Panel Cluster (IPC) Using the manufacturer approved diagnostic
Control Module - system, complete a CAN network integrity test
No sub type Refer to the electrical circuit diagrams and
information check the CAN network between the front seat
climate control module and instrument cluster
Carry out on demand self test using
manufacturer approved diagnostic system to
confirm rectification

U0156- Lost Lost communication Refer to the electrical circuit diagrams and
00 Communication with rear seat check the power and ground connections to the
With Information entertainment control module
Center "A" - No sub module Using the manufacturer approved diagnostic
type information system, complete a CAN network integrity test
Refer to the electrical circuit diagrams and
check the CAN network between the front seat
climate control module and rear seat
entertainment control module
Carry out on demand self test using
manufacturer approved diagnostic system to
confirm rectification

U0300- Internal Control Software stored in Check the front seat climate control module is
00 Module Software front seat climate configured correctly
Incompatibility - control module is not Reconfigure the front seat climate control
No sub type compatible with master module using the manufacturer approved
information configuration diagnostic system. Clear the DTC and retest the
system
Carry out on demand self test using
manufacturer approved diagnostic system to
confirm rectification

U0401- Invalid Data The engine control Check the engine control module for related
00 Received From module has transmitted DTCs and refer to the relevant DTC index
ECM/PCM - No engine speed quality On software levels previous to 8X23-14B663-
sub type factor CAN signal at a AE clear the DTC and take no further action if
information specific value for a the system is operating correctly
greater than expected
time period

U2101- Control module Compatible central car Using the manufacturer approved diagnostic
00 Configuration configuration file not system check and update the car configuration
Incompatible - No received by front seat file as required. Carry out on demand self test
sub type climate control module using manufacturer approved diagnostic system
information to confirm rectification. Clear the DTC and
retest

U3000- Control Module - Front seat climate Check and install new front seat climate control
04 System internal control module - module as required. Carry out on demand self
failures Internal failure test using manufacturer approved diagnostic
system to confirm rectification

U3003- Battery Voltage - Wiring harness fault Refer to the electrical circuit diagrams and
62 Signal compare Battery internal failure check the power and ground connections to the
failure Charging system fault front seat climate control module and the
central junction box
Refer to the battery care manual and verify that
the vehicle battery is fully charged and
serviceable before continuing with further
diagnostic tests
Check the vehicle charging system
Published: 17-Apr-2014

2012.0 XF (X250), 100-00

General Information

Diagnostic Trouble Code Index - DTC: Gateway


Module (GWM) (G1426790)
DESCRIPTION AND OPERATION
Gateway Module (GWM)
CAUTION:

Diagnosis by substitution from a donor vehicle is NOT acceptable. Substitution of control modules does not
guarantee confirmation of a fault, and may also cause additional faults in the vehicle being tested and/or the donor
vehicle

NOTES:

If the control module or a component is suspect and the vehicle remains under manufacturer warranty, refer to
the Warranty Policy and Procedures manual, or determine if any prior approval programme is in operation,
prior to the installation of a new module/component.

Generic scan tools may not read the codes listed, or may read only 5-digit codes. Match the 5 digits from the
scan tool to the first 5 digits of the 7-digit code listed to identify the fault (the last 2 digits give extra
information read by the manufacturer-approved diagnostic system)

When performing voltage or resistance tests, always use a digital multimeter accurate to three decimal places
and with a current calibration certificate. When testing resistance, always take the resistance of the digital
multimeter leads into account

Check and rectify basic faults before beginning diagnostic routines involving pinpoint tests

Inspect connectors for signs of water ingress, and pins for damage and/or corrosion

If diagnostic trouble codes are recorded and, after performing the pinpoint tests, a fault is not present, an
intermittent concern may be the cause. Always check for loose connections and corroded terminals

Where an 'on demand self-test' is referred to, this can be accessed via the 'diagnostic trouble code monitor' tab
on the manufacturers approved diagnostic system

Check DDW for open campaigns. Refer to the corresponding bulletins and SSMs which may be valid for the
specific customer complaint and carry out the recommendations as required.

The table below lists all diagnostic trouble codes (DTCs) that could be logged in the gateway module, for additional
diagnosis and testing information refer to the relevant diagnosis and testing section. For additional information, refer
to: Communications Network (418-00 Module Communications Network, Diagnosis and Testing).

DTC Description Possible Causes Action


B1087- LIN Bus 'A' - Erratic Gateway module/dual Refer to the electrical circuit diagrams
8F battery module wiring and check local interconnect network
harness fault between gateway module and dual
Module communications battery module. Repair wiring harness as
fault - local interconnect required. Clear DTC and retest
network gateway module Re-configure the gateway module using
and dual battery module the manufacturer approved diagnostic
corrupted system. Clear DTCs and retest
Dual battery module fault If fault persists, check and install a new
Gateway module fault dual battery module
If fault persists, check and install a new
gateway module
Refer to the warranty policy and
procedures manual, or determine if any
prior approval programme is in
operation, prior to the installation of a
new module/component

B13C3- Dual Battery Module Gateway module wiring Refer to the electrical circuit diagrams
92 - Dual Battery Fuse harness fault - Circuit and check the connection between the
Box - Performance or MESS_NEG - Check gateway module and the dual battery
incorrect operation connections are secure and fuse box - Circuit MESS_NEG - Check
wiring integrity connections are secure and wiring
Dual battery fuse box integrity
module wiring harness fault Refer to the electrical circuit diagrams
- Circuit and check the connection between the
FET_DIAGNOSTICS - dual battery fuse box and the gateway
Check connections are module - Circuit FET_DIAGNOSTICS -
secure and wiring integrity Check connections are secure and wiring
Dual battery fuse box integrity
component internal failure If no wiring/connector faults are found,
Gateway module failure check and install a new dual battery fuse
box. Run dual battery system diagnostic
service routine. Clear DTC and retest
If fault persists, check and install a new
gateway module. Clear DTC and run
dual battery system diagnostic service
routine, then retest
Refer to the warranty policy and
procedures manual, or determine if any
prior approval programme is in
operation, prior to the installation of a
new module/component

B13C3- Dual Battery Module Dual battery fuse box Clear DTC and retest. If fault persists,
96 - Dual Battery Fuse component internal failure check and install a new dual battery fuse
Box - Component box and run dual battery system
internal failure diagnostic service routine

B13C4- Dual Battery Module Dual battery module Clear DTC and retest. If fault persists,
96 - Component internal component internal failure check and install a new dual battery
failure module and run dual battery system
diagnostic service routine

B13C5- Secondary Battery - Secondary battery wiring Refer to the electrical circuit diagrams
92 Performance or issue and check connections are secure and
incorrect operation Secondary battery degraded wiring integrity of gateway module
Dual battery module failure circuit - Circuit MESS_POS
Refer to the electrical circuit diagrams
and check connections are secure and
wiring integrity of dual battery fuse box
circuits - Circuit GATEWAY, Circuit
BATT_2
Refer to the electrical circuit diagrams
and check power and ground
connections of second battery
If no wiring/connector faults are found,
check condition of second battery and
replace as required. Run secondary
battery diagnostic service routine. Clear
DTC and retest.
If fault persists, check and install a new
dual battery module. Clear DTC and
retest.

B1402- Dual Battery Fuse Dual battery module wiring Refer to the electrical circuit diagrams
96 Box - Contactor 1 - harness fault - Circuit and check the contactor 1 control circuit
Component internal CONTACTOR_1_CTRL, between the dual battery module and the
failure Circuit GND - Check dual battery fuse box - Circuit
connections are secure and CONTACTOR_1_CTRL, Circuit GND
wiring integrity - Check connections are secure and
Dual battery fuse box wiring integrity
module wiring harness fault Refer to the electrical circuit diagrams
- Circuit and check the dual battery fuse box
FET_DIAGNOSTICS, circuits - Circuit FET_DIAGNOSTICS,
Circuit GND - Check Circuit GND - Check connections are
connections are secure and secure and wiring integrity
wiring integrity If no wiring/connector faults are found,
Dual battery module failure check and install a new dual battery
Dual battery fuse box failure module. Run dual battery system
Gateway module failure diagnostic service routine. Clear DTC
and retest
If fault persists, check and install a new
dual battery fuse box and run dual
battery system diagnostic service routine
If fault persists, check and install a new
gateway module. Clear DTC and run
dual battery system diagnostic service
routine, then retest
Refer to the warranty policy and
procedures manual, or determine if any
prior approval programme is in
operation, prior to the installation of a
new module/component

B1403- Dual Battery Fuse Dual battery module wiring Refer to the electrical circuit diagrams
96 Box - Contactor 2 - harness fault - Circuit and check the contactor 2 control circuit
Component internal CONTACTOR_2_CTRL, between the dual battery module and the
failure Circuit GND - Short circuit dual battery fuse box - Circuit
to ground, short circuit to CONTACTOR_2_CTRL, Circuit GND
power, open circuit, high - Check connections are secure and
resistance wiring integrity
Dual battery fuse box Refer to the electrical circuit diagrams
module wiring harness fault and check the dual battery fuse box
- Circuit BATT_2, Circuit circuits - Circuit BATT_2, Circuit
GATEWAY, Circuit GND - GATEWAY, Circuit GND - Check
Short circuit to ground, connections are secure and wiring
short circuit to power, open integrity
circuit, high resistance If no wiring/connector faults are found,
Dual battery module failure check and install a new dual battery
Dual battery fuse box failure module. Run dual battery system
Gateway module failure diagnostic service routine. Clear DTC
and retest
If fault persists, check and install a new
dual battery fuse box and run dual
battery system diagnostic service routine
If fault persists, check and install a new
gateway module. Clear DTC and run
dual battery system diagnostic service
routine, then retest
Refer to the warranty policy and
procedures manual, or determine if any
prior approval programme is in
operation, prior to the installation of a
new module/component

B1404- Charging System - Possible charging system Refer to relevant section of workshop
64 Signal plausibility fault manual and battery care manual. Check
failure battery state of charge and
starting/charging system performance
Refer to relevant section of workshop
manual and run charging system on
demand self-test routines as directed

U0001- High speed CAN High speed CAN failure - Refer to the electrical circuit diagrams
88 communication Bus - bus off and check the high speed CAN bus for
Bus off short circuit to ground, short circuit to
power, open circuit, high resistance

U0010- Medium speed CAN Medium speed CAN failure Refer to the electrical circuit diagrams
88 communication Bus - - bus off and check the medium speed CAN bus
Bus off for short circuit to ground, short circuit
to power, open circuit, high resistance

U3000- Control module - Gateway module internal Re-configure the gateway module using
46 Calibration/parameter fault - corrupt non-volatile the manufacturer approved diagnostic
memory failure memory system. Clear DTCs and retest
If fault persists, check and install a new
gateway module
Refer to the warranty policy and
procedures manual, or determine if any
prior approval programme is in
operation, prior to the installation of a
new module/component

U1A14- CAN Initialisation Gateway module internal Clear DTC and retest. Refer to the
00 Failure - No sub type fault - CAN transceiver electrical circuit diagrams and check the
information failure power and ground connections to the
CAN fault gateway module. Using the
manufacturer approved diagnostic
system, complete a CAN network
integrity test
If fault persists, check and install a new
gateway module as required
Refer to the warranty policy and
procedures manual, or determine if any
prior approval programme is in
operation, prior to the installation of a
new module

U2100- Initial Configuration Incorrectly configured Re-configure the central junction box
00 Not Complete - No central junction box using the manufacturer approved
sub type information CAN fault diagnostic system. Clear DTC and retest
Central junction box fault Refer to the electrical circuit diagrams
and check the power and ground
connections to the central junction box
and the gateway module
Using the manufacturer approved
diagnostic system, complete a CAN
network integrity test. Refer to the
electrical circuit diagrams and check the
CAN network between the central
junction box and gateway module. Clear
DTC and retest
If fault persists, check and install a new
central junction box as required
Refer to the warranty policy and
procedures manual, or determine if any
prior approval programme is in
operation, prior to the installation of a
new module

U2101- Control Module Car configuration file Using the manufacturer approved
00 Configuration mismatch diagnostic system check and update the
Incompatible - No Gateway module not car configuration file as required. Clear
sub type information correctly configured DTC and retest
Gateway module fault Re-configure the gateway module using
the manufacturer approved diagnostic
system. Clear DTC and retest
If fault persists, check and install a new
gateway module as required
Refer to the warranty policy and
procedures manual, or determine if any
prior approval programme is in
operation, prior to the installation of a
new module

U3000- Control Module - Gateway module internal Clear DTC and retest. Check and install
04 System Internal failure a new gateway module as required
Failures Run dual battery system diagnostic
service routine to confirm fault is
cleared
Refer to the warranty policy and
procedures manual, or determine if any
prior approval programme is in
operation, prior to the installation of a
new module
Published: 17-Apr-2014

2012.0 XF (X250), 100-00

General Information

Diagnostic Trouble Code Index - DTC: Headlamp


Control Module (HCM) (G1426791)
DESCRIPTION AND OPERATION
Headlamp Control Module (HCM)
CAUTION:

Diagnosis by substitution from a donor vehicle is NOT acceptable. Substitution of control modules does not
guarantee confirmation of a fault, and may also cause additional faults in the vehicle being tested and/or the donor
vehicle

NOTES:

If the control module or a component is suspect and the vehicle remains under manufacturer warranty, refer to
the warranty policy and procedures manual, or determine if any prior approval programme is in operation,
prior to the installation of a new module/component

Generic scan tools may not read the codes listed, or may read only 5-digit codes. Match the 5 digits from the
scan tool to the first 5 digits of the 7-digit code listed to identify the fault (the last 2 digits give extra
information read by the manufacturer approved diagnostic system)

When performing voltage or resistance tests, always use a digital multimeter accurate to three decimal places,
and with an up-to-date calibration certificate. When testing resistance, always take the resistance of the digital
multimeter leads into account

Check and rectify basic faults before beginning diagnostic routines involving pinpoint tests

Inspect connectors for signs of water ingress, and pins for damage and/or corrosion

If diagnostic trouble codes are recorded and, after performing the pinpoint tests a fault is not present, an
intermittent concern may be the cause. Always check for loose connections and corroded terminals

Where an 'on demand self-test' is referred to, this can be accessed via the 'DTC Monitor' tab on the
manufacturers approved diagnostic system

Check DDW for open campaigns. Refer to the corresponding bulletins and SSM's which may be valid for the
specific customer complaint and carry out the recommendations as needed.

The table below lists all diagnostic trouble codes (DTCs) that could be logged in the headlamp control module, for
additional diagnosis and testing information refer to the relevant diagnosis and testing section. For additional
information, refer to: Headlamps (417-01 Exterior Lighting, Diagnosis and Testing).

DTC Description Possible Causes Action


B1041- Leveling No headlamp Install a new headlamp control module as required. Refer to
04 Control - control module the warranty policy and procedures manual, or determine if
System internal functionality- any prior approval programme is in operation, prior to the
failures module installation of a new module
internal failure
B1041- Leveling Leveling NOTE:
54 Control - sensor
Missing calibration Sensor calibration routine must be carried out with the vehicle
calibration routine not unladen and with correct tire pressures
carried out
Carry out the leveling sensor calibration routine using the
manufacturer approved diagnostic system

B1087- LIN Bus "A" - LIN bus circuit Clear the DTC and re-test. If the DTC remains, install a
83 Value of signal fault - new headlamp control module. Refer to the warranty policy
protection checksum error and procedures manual, or determine if any prior approval
calculation programme is in operation, prior to the installation of a new
incorrect module

B1087- LIN Bus "A" - LIN bus circuit Clear the DTC and re-test. If the DTC remains, install a
86 Signal invalid fault - Signal new headlamp control module. Refer to the warranty policy
invalid and procedures manual, or determine if any prior approval
programme is in operation, prior to the installation of a new
module

B1087- LIN Bus "A" - Bus off - LIN Refer to the electrical circuit diagrams and check the LIN
88 Bus off bus circuit bus circuit for short circuit to ground. Check for other
short circuit to related DTCs
ground

B10AE- Headlamp Headlamp Refer to the electrical circuit diagrams and check headlamp
11 Leveling Motor leveling motor leveling motor control circuit for short circuit to ground
- Circuit short control circuit - and the headlamp leveling motor signal voltage
to ground short circuit to
ground

B10AE- Headlamp Headlamp Refer to the electrical circuit diagrams and check headlamp
12 Leveling Motor leveling motor leveling motor control circuit for short circuit to power
- Circuit short control circuit -
to battery short circuit to
power

B10AE- Headlamp Headlamp Refer to the electrical circuit diagrams and check the DC
64 Leveling Motor leveling motor motor signal circuit for short circuit to ground, short circuit
- Signal - Signal to power, open circuit, high resistance. Check for other
plausibility plausibility related DTCs
failure failure

B1A59- Sensor 5 Volt Headlamp Refer to the electrical circuit diagrams and check headlamp
11 Supply - Circuit leveling sensor leveling sensor 5 volt supply circuit for short circuit to
short to ground 5 volt supply ground
circuit - short
circuit to
ground

B1A59- Sensor 5 Volt Headlamp Refer to the electrical circuit diagrams and check headlamp
12 Supply - Circuit leveling sensor leveling sensor 5 volt supply circuit for short circuit to
short to battery 5 volt supply power
circuit - short
circuit to
power

B1D64- Left Headlamp General Check the headlamp connections, clear the DTC and re-
01 Swivelling electrical test. If the DTC remains, install a new headlamp. Refer to
Motor - General failure - left the warranty policy and procedures manual, or determine if
electrical headlamp any prior approval programme is in operation, prior to the
failure swivelling installation of a new component
motor error

B1D64- Left Headlamp System internal Check the headlamp connections, clear the DTC, switch off
04 Swivelling failure - left the ignition and allow sufficient time for the module to
Motor - System headlamp power down - then re-test. If the DTC persists, install a new
internal failures swivelling headlamp. Refer to the warranty policy and procedures
motor error manual, or determine if any prior approval programme is in
operation, prior to the installation of a new component

B1D64- Left Headlamp Left headlamp Check the headlamp connections. Refer to the electrical
87 Swivelling swivelling circuit diagrams and check power and ground supplies to
Motor - motor - headlamp adaptive front lighting system modules. Clear
Missing Missing DTC and re-test. If DTC remains, install a new headlamp.
message message Refer to the warranty policy and procedures manual, or
determine if any prior approval programme is in operation,
prior to the installation of a new component

B1D65- Right General Clear the DTC and re-test. If the DTC remains, install a
01 Headlamp electrical new headlamp. Refer to the warranty policy and procedures
Swivelling failure - right manual, or determine if any prior approval programme is in
Motor - General headlamp operation, prior to the installation of a new component
electrical swivelling
failure motor error

B1D65- Right System internal Check the headlamp connections, clear the DTC, switch off
04 Headlamp failure - right the ignition and allow sufficient time for the module to
Swivelling headlamp power down - then re-test. If the DTC persists, install a new
Motor - System swivelling headlamp. Refer to the warranty policy and procedures
internal failures motor error manual, or determine if any prior approval programme is in
operation, prior to the installation of a new component

B1D65- Right Right Check the headlamp connections. Refer to the electrical
87 Headlamp headlamp circuit diagrams and check power and ground supplies to
Swivelling swivelling headlamp adaptive front lighting system modules. Clear
Motor - motor - DTC and re-test. If DTC remains, install a new headlamp.
Missing Missing Refer to the warranty policy and procedures manual, or
message message determine if any prior approval programme is in operation,
prior to the installation of a new component

B1D68- Left Headlamp Left headlamp Check the headlamp connector for integrity. Refer to the
00 Swivelling swivelling electrical circuit diagrams and check headlamp circuit.
Feedback feedback Clear DTC and re-test, if DTC remains, install a new
Sensor - No sub sensor not headlamp. Refer to the warranty policy and procedures
type detected manual, or determine if any prior approval programme is in
information operation, prior to the installation of a new component

B1D69- Right Right Check the headlamp connector for integrity. Refer to the
00 Headlamp headlamp electrical circuit diagrams and check headlamp circuit.
Swivelling swivelling Clear DTC and re-test, if DTC remains, install a new
Feedback feedback headlamp. Refer to the warranty policy and procedures
Sensor - No sub sensor not manual, or determine if any prior approval programme is in
type detected operation, prior to the installation of a new component
information
C1A04- Right Front Front height Check the ride level control module for DTCs. Check the
11 Height Sensor - sensor harness sensor connector for damage. Refer to the electrical circuit
Circuit short to wiring - short diagrams and check the sensor circuit for short circuit to
ground circuit to ground, open circuit, high resistance. Check sensor signal
ground changes when sensor is rotated. If any height sensor fixings
are slackened or found to be loose, or if a height sensor has
been changed, the vehicle ride height must be re-calibrated.
Carry out the calibration routine using the manufacturer
approved diagnostic system

C1A04- Right Front Front height Check the ride level control module for DTCs. Check the
15 Height Sensor - sensor harness sensor connector for damage. Refer to the electrical circuit
Circuit short to wiring - short diagrams and check the sensor circuit for short circuit to
battery or open circuit to power, open circuit, high resistance. Check sensor signal
power, open changes when sensor is rotated. If any height sensor fixings
circuit, high are slackened or found to be loose, or if a height sensor has
resistance been changed, the vehicle ride height must be re-calibrated.
Carry out the calibration routine using the manufacturer
approved diagnostic system

C1A04- Right Front Front height NOTE:


64 Height Sensor - sensor - Signal
Signal plausibility This DTC may be logged if the vehicle's wheels have been raised
plausibility failure from the floor
failure
Check the ride level control module for DTCs. Check the
sensor connector for damage. Refer to the electrical circuit
diagrams and check the sensor circuit for short circuit to
ground, short circuit to power, open circuit, high resistance.
Check sensor signal changes when sensor is rotated. If any
height sensor fixings are slackened or found to be loose, or
if a height sensor has been changed, the vehicle ride height
must be re-calibrated. Carry out the calibration routine
using the manufacturer approved diagnostic system

C1A06- Right Rear Rear height Check the ride level control module for DTCs. Check the
11 Height Sensor - sensor harness sensor connector for damage. Refer to the electrical circuit
Circuit short to wiring - short diagrams and check the sensor circuit for short circuit to
ground circuit to ground, open circuit, high resistance. Check sensor signal
ground changes when sensor is rotated. If any height sensor fixings
are slackened or found to be loose, or if a height sensor has
been changed, the vehicle ride height must be re-calibrated.
Carry out the calibration routine using the manufacturer
approved diagnostic system

C1A06- Right Rear Rear height Check the ride level control module for DTCs. Check the
15 Height Sensor - sensor harness sensor connector for damage. Refer to the electrical circuit
Circuit short to wiring - short diagrams and check the sensor circuit for short circuit to
battery or open circuit to power, open circuit, high resistance. Check sensor signal
power, open changes when sensor is rotated. If any height sensor fixings
circuit, high are slackened or found to be loose, or if a height sensor has
resistance been changed, the vehicle ride height must be re-calibrated.
Carry out the calibration routine using the manufacturer
approved diagnostic system

C1A06- Right Rear Rear height NOTE:


64 Height Sensor - sensor - Signal
Signal plausibility This DTC may be logged if the vehicle's wheels have been raised
plausibility failure from the floor
failure
Check the ride level control module for DTCs. Check the
sensor connector for damage. Refer to the electrical circuit
diagrams and check the sensor circuit for short circuit to
ground, short circuit to power, open circuit, high resistance.
Check sensor signal changes when sensor is rotated. If any
height sensor fixings are slackened or found to be loose, or
if a height sensor has been changed, the vehicle ride height
must be re-calibrated. Carry out the calibration routine
using the manufacturer approved diagnostic system

U0001- High Speed Bus off - CAN Refer to the electrical circuit diagrams and check the power
88 CAN bus and ground connections to the central junction box. Using
Communication communication the manufacturer approved diagnostic system, complete a
Bus - Bus off error CAN network integrity test. Refer to the electrical circuit
diagrams and check the CAN network

U0101- Lost Lost Refer to the electrical circuit diagrams and check the power
00 Communication communication and ground connections to the transmission control module.
with with Using the manufacturer approved diagnostic system,
Transmission transmission complete a CAN network integrity test. Refer to the
Control Module control module electrical circuit diagrams and check the CAN network
- No sub type - CAN bus between the transmission control module and headlamp
information communication control module
error

U0102- Lost Lost Refer to the electrical circuit diagrams and check the power
00 Communication communication and ground connections to the transfer case control module.
with Transfer with transfer Using the manufacturer approved diagnostic system,
Case Control case control complete a CAN network integrity test. Refer to the
Module - No module - CAN electrical circuit diagrams and check the CAN network
sub type bus between the transfer case control module and headlamp
information communication control module
error

U0121- Lost Lost Refer to the electrical circuit diagrams and check the power
00 Communication communication and ground connections to the ABS module. Using the
With ABS with ABS manufacturer approved diagnostic system, complete a CAN
Control Module control module network integrity test. Refer to the electrical circuit
- No sub type - CAN bus diagrams and check the CAN network between the ABS
information communication module and headlamp control module
error

U0126- Lost Lost Refer to the electrical circuit diagrams and check the power
00 Communication communication and ground connections to the steering angle sensor
With Steering with steering module. Using the manufacturer approved diagnostic
Angle Sensor angle sensor system, complete a CAN network integrity test. Refer to
Module - No module - CAN the electrical circuit diagrams and check the CAN network
sub type bus between the steering angle sensor control module and
information communication headlamp control module
error

U0140- Lost Lost Refer to the electrical circuit diagrams and check the power
00 Communication communication and ground connections to central junction box. Using the
With Body with central manufacturer approved diagnostic system, complete a CAN
Control Module junction box - network integrity test. Refer to the electrical circuit
- No sub type CAN bus diagrams and check the CAN network between the central
information communication junction box and headlamp control module
error

U0142- Lost Lost Refer to the electrical circuit diagrams and check the power
00 Communication communication and ground connections to the rear junction box. Using the
With Body with rear manufacturer approved diagnostic system, complete a CAN
Control Module junction box - network integrity test. Refer to the electrical circuit
"B" - No sub CAN bus diagrams and check the CAN network between the rear
type communication junction box and headlamp control module
information error

U0300- Internal Control Car Check/amend car configuration file using the manufacturer
00 Module configuration approved diagnostic system
Software file
Incompatibility information
- No sub type incompatible to
information engine control
unit

U0402- Invalid Data Invalid data Check the transmission control module for related DTCs
00 Received From received from and refer to the relevant DTC index
Transmission transmission
Control Module control module
- No sub type
information
U0403- Invalid Data Invalid data Check the transfer case control module for related DTCs
00 Received From received from and refer to the relevant DTC index
Transfer Case transfer case
Control Module control module
- No sub type
information
U0415- Invalid Data Invalid data Check the ABS module for related DTCs and refer to the
00 Received From received from relevant DTC index
Anti-Lock ABS module
Braking System
Control Module
- No sub type
information
U0428- Invalid Data Invalid data Check the steering angle sensor module for related DTCs
00 Received From received from and refer to the relevant DTC index
Steering Angle steering angle
Sensor Module sensor module
- No sub type
information
U0443- Invalid Data Invalid data Check the rear junction box for stored DTCs. Using the
00 Received From received from manufacturer approved diagnostic system, complete a CAN
Body Control rear junction network integrity test. Refer to electrical circuit diagrams -
Module "B" - box check the CAN network between the adaptive front lighting
No sub type system control module and the rear junction box
information
U2100- Initial Car Check/amend car configuration file using manufacturer
00 Configuration configuration approved diagnostic system
Not Complete - file
No sub type information not
information received
completely

U2101- Control Module Car Check/amend car configuration file using manufacturer
00 Configuration configuration approved diagnostic system
Incompatible - file
No sub type information
information incompatible to
engine control
unit

U3002- Vehicle Stored vehicle Check/amend car configuration file using manufacturer
81 Identification identification approved diagnostic system
Number - number does
Invalid serial not match most
data received recent vehicle
identification
number

U3003- Battery Voltage Circuit voltage Check vehicle battery and charging system. Refer to the
16 - Circuit below relevant section in the workshop manual. Refer to the
voltage below threshold electrical circuit diagrams and check the power and ground
threshold supply circuits to the module

U3003- Battery Voltage Circuit voltage Check vehicle battery and charging system. Refer to the
17 - Circuit above relevant section in the workshop manual. Refer to the
voltage above threshold electrical circuit diagrams and check the power and ground
threshold supply circuits to the module

U3003- Battery Voltage Mis-match in Check vehicle battery and charging system. Refer to the
62 - Signal battery voltage relevant section in the workshop manual. Refer to the
compare failure between electrical circuit diagrams and check the power and ground
central junction supply circuits to central junction box and headlamp
box and control module
headlamp
control module
of 2 volts or
more
Published: 16-Dec-2015

2012.0 XF (X250), 100-00

General Information

Diagnostic Trouble Code Index - DTC: Headlamp


Control Module B (HCMB) (G1426792)
DESCRIPTION AND OPERATION
Headlamp Control Module B (HCMB)
CAUTION:

Diagnosis by substitution from a donor vehicle is NOT acceptable. Substitution of control modules does not
guarantee confirmation of a fault and may also cause additional faults in the vehicle being checked and/or the donor
vehicle.

NOTES:

If the control module or a component is suspect and the vehicle remains under manufacturer warranty, refer to
the Warranty Policy and Procedures manual, or determine if any prior approval programme is in operation,
prior to the installation of a new module/component.

Generic scan tools may not read the codes listed, or may read only 5-digit codes. Match the 5 digits from the
scan tool to the first 5 digits of the 7-digit code listed to identify the fault (the last 2 digits give extra
information read by the manufacturer approved diagnostic system).

When performing voltage or resistance tests, always use a digital multimeter (DMM) accurate to three decimal
places, and with an up-to-date calibration certificate. When testing resistance, always take the resistance of the
DMM leads into account.

Check and rectify basic faults before beginning diagnostic routines involving pinpoint tests.

If DTCs are recorded and, after performing the pinpoint tests a fault is not present, an intermittent concern
may be the cause. Always check for loose connections and corroded terminals.

Where an 'on demand self-test' is referred to, this can be accessed via the 'DTC Monitor' tab on the
manufacturers approved diagnostic system.

Check DDW for open campaigns. Refer to the corresponding bulletins and SSMs which may be valid for the
specific customer complaint and carry out the recommendations as required.

The table below lists all Diagnostic Trouble Codes (DTCs) that could be logged in the Headlamp Control Module B,
for additional Diagnosis and Testing information refer to the relevant Diagnosis and Testing Section. For additional
information, refer to: Headlamps (417-01 Exterior Lighting, Diagnosis and Testing).

DTC Description Possible Causes Action


B1286- Interior mirror - Mirror module circuit Using the manufacturer approved
16 Circuit voltage voltage below threshold. The diagnostic system, check the datalogger
below threshold electrochromic function does signal - main ECU supply voltage
not work (0xDD02)
Mirror module power or Check the voltage between pin 1 and pin 3
ground circuit open circuit, of the mirror module connector. The
high resistance voltage should to be above 8.5 volts for
Battery/charging system normal condition
fault Refer to the electrical circuit diagrams and
Mirror module internal check the mirror module power and
failure ground circuits for open circuit, high
resistance
Refer to the relevant section of the
workshop manual and test the battery and
charging system
If the DTC is set permanent and voltage is
above 8.5 volts, clear the DTC and retest.
If the problem persists, renew the mirror
module

B1286- Interior mirror - Mirror module circuit Using the manufacturer approved
17 Circuit voltage voltage above threshold. The diagnostic system, check the datalogger
above threshold electrochromic function does signal - main ECU supply voltage
not work (0xDD02)
Battery/charging system Check the voltage between pin 1 and pin 3
fault of the mirror module connector. The
Mirror module internal voltage should to be below 16.5 volts for
failure normal condition
Check the vehicle charging system
performance to ensure the voltage
regulation is correct
Clear the DTC and retest. If the problem
persists, renew the mirror module

B1286- Interior mirror - Mirror control module data Clear the DTC and re-test
44 Data memory memory failure. The Renew the interior mirror module
failure electrochromic function does
not work

B1286- Interior mirror - Control module This DTC is for information only. Clear
47 Watchdog/safety watchdog/safety micro the DTC and retest. If the problem persists,
micro controller controller failure renew the mirror module
failure The electrochromic
function does not work

B1286- Interior mirror - Mirror internal failures Clear the DTC and re-test
49 Internal electronic (active light sensor). The Renew the mirror module
failure electrochromic function does
not work

B1286- Interior mirror - Operation temperature below Allow the vehicle interior temperature to
60 Reserved by limit increase, clear the DTC and retest.
document The electrochromic Consider the environmental conditions
function does not work before condemning the module

B1286- Interior mirror - DTC is for information only Clear the DTC and re-test
78 Alignment or and is logged whenever the
adjustment low sensitivity mode has
incorrect been activated to provide a
log of the number of times
the feature has been used
(low sensitivity mode is
cancelled when the ignition
is cycled)

B1286- Interior mirror - Lost communication with Using the manufacturer approved
96 Component central junction box diagnostic system, complete a CAN
internal failure Mirror module internal network integrity test
failure Refer to the electrical circuit diagrams and
check the CAN harness between the
central junction box and the mirror module
Using the manufacturer approved
diagnostic system, clear the DTCs and
retest. If the fault persists, install a new
mirror module

B1286- Interior mirror - Mirror internal camera Remove obstructions from the mirror
97 Component or component or system camera (remove stickers etc., clean
system operation operation obstructed or windscreen inside and out). Clear the DTC
obstructed or blocked and retest for normal operation
blocked
B1286- Interior mirror - Component or system over Consider the environmental conditions
98 Component or temperature before condemning the module. Allow the
system over component/system to cool, clear the DTC
temperature and retest for normal operation

B12AC- Electrochromic Electrochromic door mirror NOTE:


11 door mirror - output circuit short to ground
Circuit short to To aid fault finding use the manufacturer
ground approved diagnostic system to force the
automatic dim function

Refer to the electrical circuit diagrams and


check the mirror module harness,
including both exterior mirror circuits for
short circuit to ground, repair as necessary

B12AC- Electrochromic Electrochromic door mirror NOTE:


12 door mirror - output circuit short to power
Circuit short to To aid fault finding use the manufacturer
battery approved diagnostic system to force the
automatic dim function

Refer to the electrical circuit diagrams and


check the mirror module harness,
including both exterior mirror circuits for
short circuit to power, repair as necessary

B12EB- Camera horizontal Mirror module internal NOTE:


78 alignment - camera misaligned in the
Alignment or horizontal direction To trigger the possible fault conditions for this
adjustment Mirror module fault DTC, the vehicle may need to be driven during
incorrect Windscreen alignment night time conditions
incorrect
Check the mirror module for security and
correct positioning. Clear the DTC and
retest for normal operation
Renew the mirror module. See topix
workshop manual, section 417-01 exterior
lighting, description and operation for the
auto aim calibration procedure
If the problem persists, suspected
windscreen alignment incorrect

B12EC- Camera vertical Mirror module internal NOTE:


78 alignment - camera misaligned in the
Alignment or vertical direction To trigger the possible fault conditions for this
adjustment Mirror module fault DTC, the vehicle may need to be driven during
incorrect Windscreen alignment night time conditions
incorrect
Check the mirror module for security and
correct positioning. Clear the DTC and
retest for normal operation
Renew the mirror module. See topix
workshop manual, section 417-01 exterior
lighting, description and operation for the
auto aim calibration procedure
If the problem persists, suspected
windscreen alignment incorrect

B134A- Target aim NOTE: DTC for information only. Clear DTC and
78 verification - retest
Camera horizontal This DTC is for use during the
alignment - factory aim routine only
Alignment or
adjustment Mirror module internal
incorrect camera alignment or
adjustment incorrect
Mirror module fault
Windscreen alignment
incorrect

B134B- Target aim NOTE: DTC for information only. Clear DTC and
78 vertical - Camera retest
horizontal This DTC is for use during the
alignment - factory aim routine only
Alignment or
adjustment Mirror module internal
incorrect camera alignment or
adjustment incorrect
Mirror module fault
Windscreen alignment
incorrect

U0010- Medium speed Bus off Refer to the electrical circuit diagrams and
88 CAN check the power and ground connections
communication to the module. Using the manufacturer
bus - Bus off approved diagnostic system, complete a
CAN network integrity test. Refer to the
electrical circuit diagrams and check the
CAN network

U0140- Lost Lost communication with Refer to the electrical circuit diagrams and
00 communication Body Control Module check the power and ground connections
with Body Control (BCM) to the module. Using the manufacturer
Module (BCM) - approved diagnostic system, complete a
No sub type CAN network integrity test. Refer to the
information electrical circuit diagrams and check the
CAN network between the central junction
box and rain/light sensor

U0300- Internal control Internal control module Using the manufacturer approved
00 module software software incompatibility diagnostic system, ensure that the mirror
incompatibility - module contains the latest software version
No sub type and is correctly configured, update if
information necessary. Clear the DTC and retest

U201A- Control module Incorrect mirror module NOTE:


57 main calibration fitted
data - Main calibration is invalid to Due to the mechanical calibration tolerance the
Invalid/incomplete car configuration file or not correct mirror module assembly must be used for
software complete stored to the mirror the vehicle model types in question and it is not
component exchangeable with other vehicle model types

Using the manufacturers approved


diagnostic system, compare the vehicle
type in the mirror module with the car
configuration file (parameter 1), if these do
not match the incorrect mirror module has
been fitted
Using the manufacturers approved
diagnostic system, check the configuration
of the car configuration file and software
version of the mirror module is correct

U2100- Initial Initial configuration not Using the manufacturers approved


00 configuration not complete diagnostic system, check the configuration
complete - No sub of the car configuration file and the
type information software version of the mirror module is
correct
Using the manufacturer approved
diagnostic system check the central
junction box for related DTCs and refer to
the relevant DTC index
If the problem persists, renew the mirror
module

U2101- Control module Control module Using the manufacturers approved


00 configuration configuration incompatible diagnostic system, check the configuration
incompatible - No of the car configuration file
sub type
information
Published: 17-Apr-2014

2012.0 XF (X250), 100-00

General Information

Diagnostic Trouble Code Index - DTC: Instrument


Cluster (IPC) (G1426804)
DESCRIPTION AND OPERATION
Instrument Cluster (IPC)
CAUTION:

Diagnosis by substitution from a donor vehicle is NOT acceptable. Substitution of control modules does not
guarantee confirmation of a fault, and may also cause additional faults in the vehicle being tested and/or the donor
vehicle

NOTES:

If the control module or a component is suspect and the vehicle remains under manufacturer warranty, refer to
the warranty policy and procedures manual, or determine if any prior approval programme is in operation,
prior to the installation of a new module/component

Generic scan tools may not read the codes listed, or may read only 5-digit codes. Match the 5 digits from the
scan tool to the first 5 digits of the 7-digit code listed to identify the fault (the last 2 digits give extra
information read by the manufacturer approved diagnostic system)

When performing voltage or resistance tests, always use a digital multimeter accurate to three decimal places,
and with an up-to-date calibration certificate. When testing resistance, always take the resistance of the digital
multimeter leads into account

Check and rectify basic faults before beginning diagnostic routines involving pinpoint tests

Inspect connectors for signs of water ingress, and pins for damage and/or corrosion

If DTCs are recorded and, after performing the pinpoint tests a fault is not present, an intermittent concern
may be the cause. Always check for loose connections and corroded terminals

Where an 'on demand self-test' is referred to, this can be accessed via the 'DTC Monitor' tab on the
manufacturers approved diagnostic system

Check DDW for open campaigns. Refer to the corresponding bulletins and SSMs which may be valid for the
specific customer complaint and carry out the recommendations as needed

The table below lists all diagnostic trouble codes (DTCs) that could be logged in the instrument panel cluster, for
additional diagnosis and testing information refer to the relevant diagnosis and testing section. For additional
information, refer to: Instrument Cluster (413-01 Instrument Cluster, Diagnosis and Testing).

DTC Description Possible Causes Action


B1008- Wiper mode switch - Wiring harness fault - Refer to electrical circuit diagrams and check
11 Circuit short to short circuit to ground the wiper switch circuits for short to ground.
ground Switch fault Clear DTC and retest
Repair wiring harness or replace switch as
required. Clear DTC and retest
B1008- Wiper mode switch - Wiring harness fault - Refer to electrical circuit diagrams and check
15 Circuit short to power short circuit to power, the wiper switch circuits for short circuit to
or open open circuit, high power, open circuit, high resistance. Clear
resistance DTC and retest
Switch fault Repair wiring harness or replace switch as
required. Clear DTC and retest

B1009- Ignition authorisation Faulty instrument Refer to the electrical circuit diagrams and
51 - Not programmed cluster check the ignition, power and ground
Re-synchronisation connections to central junction box and
error following instrument cluster
programming Re-synchronise ID by re-configuring the
CAN fault instrument cluster as a new module. Clear
DTC and retest
Using the manufacturer approved diagnostic
system, complete a CAN network integrity
test. Refer to the electrical circuit diagrams
and check the CAN network between the
instrument cluster and the central junction box

B1009- Ignition authorisation Central junction box Refer to the electrical circuit diagrams and
62 - Signal compare fault check the power and ground connections to the
failure Instrument cluster central junction box and instrument cluster
fault Using the manufacturer approved diagnostic
Low speed CAN fault system, complete a CAN network integrity
Incorrect module test. Refer to the electrical circuit diagrams
installed (central and check the CAN network between the
junction central junction box and instrument cluster
box/instrument Confirm correct central junction
cluster) box/instrument cluster module is installed
Re-synchronisation Re-synchronise ID by re-configuring the
error following re- instrument cluster as a new module. Clear
programming DTC and retest
Noise/electromagnetic Check CAN network for
compatibility related interference/electromagnetic compatibility
error related issues. Ensure that the vehicle is away
from sources of electromagnetic interference
prior to clearing DTCs and retesting

B1009- Ignition authorisation Central junction box Refer to the electrical circuit diagrams and
87 - Missing message fault check the power and ground connections to the
Instrument cluster central junction box and instrument cluster
fault Check battery is fully charged and in
Low battery voltage < serviceable condition, refer to the battery care
9 volts manual
Low speed CAN fault Using the manufacturer approved diagnostic
system, complete a CAN network integrity
test. Refer to the electrical circuit diagrams
and check the CAN network between the
central junction box and instrument cluster.
Clear DTC and retest

B100A- Fuel pump Central junction box Refer to the electrical circuit diagrams and
62 authorisation - Signal fault check the power and ground connections to the
compare failure Instrument cluster central junction box and instrument cluster
fault Using the manufacturer approved diagnostic
Low speed CAN fault system, complete a CAN network integrity
Incorrect module test. Refer to the electrical circuit diagrams
installed (central and check the CAN network between the
junction central junction box and instrument cluster
box/instrument Confirm correct central junction
cluster) box/instrument cluster module installed
Module ID Re-synchronise ID by re-configuring the
synchronisation error central junction box as a new module
following re- Check CAN network for
programming interference/electromagnetic compatibility
Noise/electromagnetic related issues. Ensure that the vehicle is away
compatibility related from sources of electromagnetic interference
error prior to clearing DTCs and retesting

B100A- Fuel Pump Module ID Re-synchronise ID by re-configuring the


64 authorisation - Signal synchronisation error central junction box as a new module
plausibility failure following re- Refer to the electrical circuit diagrams and
programming check the ignition, power and ground
Central junction box connections to the central junction box and
fault instrument cluster
Low speed CAN fault Using the manufacturer approved diagnostic
system, complete a CAN network integrity
test. Refer to the electrical circuit diagrams
and check the CAN network between the
central junction box and instrument cluster

B100A- Fuel pump Central junction box Refer to the electrical circuit diagrams and
87 authorisation - fault check the power and ground connections to the
Missing message Instrument cluster central junction box and instrument cluster
fault Check battery is fully charged and in
Low battery voltage < serviceable condition, refer to the battery care
9 volts manual
Low speed CAN fault Using the manufacturer approved diagnostic
system, complete a CAN network integrity
test. Refer to the electrical circuit diagrams
and check the CAN network between the
central junction box and instrument cluster.
Clear DTC and retest

B100B- Column lock ground Central junction box Refer to the electrical circuit diagrams and
67 authorisation - Signal fault check the power and ground connections to the
incorrect after event Instrument cluster central junction box and instrument cluster
fault Using the manufacturer approved diagnostic
Low speed CAN fault system, complete a CAN network integrity
Vehicle speed present test. Refer to the electrical circuit diagrams
when attempting to and check the CAN network between the
power steering central junction box and instrument cluster.
column lock Clear DTC and retest
Engine speed present Check ABS module, engine control module
when attempting to and central junction box for DTCs and refer to
power steering the relevant DTC index
column lock
Power mode status >
4 when attempting to
perform lock action

B100B- Column lock ground Central junction box Refer to the electrical circuit diagrams and
87 authorisation - fault check the power and ground connections to the
Missing message Instrument cluster central junction box and instrument cluster
fault Using the manufacturer approved diagnostic
Low speed CAN fault system, complete a CAN network integrity
test. Refer to the electrical circuit diagrams
and check the CAN network between the
central junction box and instrument cluster.
Clear DTC and retest

B100C- Column lock supply Central junction box Refer to the electrical circuit diagrams and
67 authorisation - Signal fault check the power and ground connections to the
incorrect after event Instrument cluster central junction box and instrument cluster
fault Using the manufacturer approved diagnostic
Low speed CAN fault system, complete a CAN network integrity
Vehicle speed present test. Refer to the electrical circuit diagrams
when attempting to and check the CAN network between the
power steering central junction box and instrument cluster.
column lock Clear DTC and retest
Engine speed present Check ABS module, engine control module
when attempting to and central junction box for DTCs and refer to
power steering the relevant DTC index
column lock
Power mode status >
4 when attempting to
perform lock action

B100C- Column lock supply Central junction box Refer to the electrical circuit diagrams and
87 authorisation - fault check the power and ground connections to the
Missing message Instrument cluster central junction box and instrument cluster
fault Using the manufacturer approved diagnostic
Low speed CAN fault system, complete a CAN network integrity
test. Refer to the electrical circuit diagrams
and check the CAN network between the
central junction box and instrument cluster.
Clear DTC and retest

B100D- Column lock Steering column lock Refer to the electrical circuit diagrams and
62 authorisation - Signal fault check the power and ground connections to the
compare failure Instrument cluster steering column lock and instrument cluster
fault Using the manufacturer approved diagnostic
CAN fault system, complete a CAN network integrity
Incorrect module test. Refer to the electrical circuit diagrams
installed (Steering and check the CAN network between the
column steering column lock and instrument cluster.
lock/instrument Clear DTC and retest
cluster) Confirm the correct steering column
Target ID lock/instrument cluster modules are installed
synchronisation error Re-synchronize ID by re-configuring the
following re- steering column lock as new
programming Check CAN network for
Noise/electromagnetic interference/electromagnetic compatibility
compatibility related related issues. Ensure that the vehicle is away
error from sources of electromagnetic interference
prior to clearing DTCs and retesting

B100D- Column lock Steering column lock Refer to the electrical circuit diagrams and
64 authorisation - Signal fault check the power and ground connections to the
plausibility failure Instrument cluster steering column lock and instrument cluster
fault Using the manufacturer approved diagnostic
CAN fault system, complete a CAN network integrity
test. Refer to the electrical circuit diagrams
and check the CAN network between the
steering column lock and instrument cluster.
Clear DTC and retest

B100D- Column Lock Missing message Clear DTC, repeatedly lock and unlock car
87 Authorisation - CAN fault using the key fob and retest. Check for related
Missing message No response from DTCs and refer to the relevant DTC index
electric steering If the fault is cleared, notify the customer that
column lock control the steering column lock may fail to unlock if
module, instrument the vehicle is parked with a high steering angle
cluster, central or with the road wheel against a curb. If the
junction box column lock is failing to disengage, the
Battery voltage at customer may be able to rectify this by
electric steering rotating the steering wheel while pressing the
column lock control engine start button
module too low If fault persists, complete a CAN network
Electric steering integrity test using the manufacturers approved
column lock control diagnostic system. Alternatively, refer to the
module, instrument electrical circuit diagrams and check CAN
cluster, central circuits between the central junction box, the
junction box fault instrument cluster and the electronic steering
column lock. Refer to the electrical circuit
diagrams and check the central junction box,
the instrument cluster and the electronic
steering column lock power and ground supply
circuits for short circuit to ground, short circuit
to power, open circuit, high resistance. Repair
circuit(s) as required. Clear DTC, perform an
on demand self-test and retest
If fault persists, check that the vehicle battery
supply voltage is between 9-16 volts. Rectify
as required

B100D- Column Lock Battery voltage at Clear DTC, repeatedly lock and unlock car
96 Authorisation - electric steering using the key fob and retest
Component internal column lock control If fault persists, check that the vehicle battery
failure module too low supply voltage is between 9-16 volts. Rectify
Torque load on as required
steering column Ensure the column lock bolt movement is not
CAN fault obstructed or restricted (the parked position of
Electric steering the road wheels may be exerting a turning
column lock control force through the steering column, preventing
module - Internal the lock from releasing. The steering wheel
failure may need to be held against the force to allow
the column lock to release). Clear DTC,
repeatedly lock and unlock car using the key
fob and retest
If fault persists, complete a CAN network
integrity test using the manufacturers approved
diagnostic system. Alternatively, refer to the
electrical circuit diagrams and check CAN
circuits between the central junction box, the
instrument cluster and the electronic steering
column lock. Refer to the electrical circuit
diagrams and check the central junction box,
the instrument cluster and the electronic
steering column lock power and ground supply
circuits for short circuit to ground, short circuit
to power, open circuit, high resistance. Repair
circuit(s) as required. Clear DTC, perform an
on demand self-test and retest
If fault persists, check and install a new
electric steering column lock control module
as required

B1024- Start Control Unit - Loss of LIN Refer to the electrical circuit diagrams and
87 Missing message communication with check the power and ground connections to the
start control unit start control unit. Refer to circuit diagrams and
Start control unit check LIN bus circuits. Clear DTC and retest
failure If no circuit faults are present, check and
install new start control unit as required. Refer
to the warranty policy and procedures manual,
or determine if any prior approval programme
is in operation, prior to the installation of a
new module/component

B1048- Brake Fluid Level Wiring harness fault - Refer to electrical circuit diagrams and check
11 Switch - Circuit short short circuit to ground the brake fluid level switch circuits for short
to ground Switch fault circuit to ground. Repair wiring harness as
required. Clear DTC and retest
If no circuit faults are present, check and
install new switch as required. Clear DTC and
retest

B10A0- Wiper/washer switch Wiring harness fault - Refer to electrical circuit diagrams and check
11 - Circuit short to short circuit to ground the wiper/washer switch circuits for short
ground Switch fault circuit to ground. Repair wiring harness as
required. Clear DTC and retest
If no circuit faults are present, check and
install new switch as required. Clear DTC and
retest

B10A0- Wiper/washer switch Wiring harness fault - Refer to electrical circuit diagrams and check
15 - Circuit short to short circuit to power, the wiper/washer switch circuits for short
battery or open open circuit, high circuit to power, open circuit, high resistance.
resistance Repair wiring harness as required. Clear DTC
Switch fault and retest
If no circuit faults are present, check and
install new switch as required. Clear DTC and
retest

B10A6- Main light switch - Wiring harness fault - Refer to electrical circuit diagrams and check
11 Circuit short to short circuit to ground the main light switch circuits for short circuit
ground Switch fault to ground. Repair wiring harness as required.
Clear DTC and retest
If no circuit faults are present, check and
install new switch as required. Clear DTC and
retest
B10A6- Main light switch - Wiring harness fault - Refer to electrical circuit diagrams and check
15 Circuit short to short circuit to power, the main light switch circuits for short circuit
battery or open open circuit, high to power, open circuit, high resistance. Repair
resistance wiring harness as required. Clear DTC and
Switch fault retest
If no circuit faults are present, check and
install new switch as required. Clear DTC and
retest

B10AC- Cruise control switch Loss of LIN Refer to the electrical circuit diagrams and
87 - Missing message communication with check the power and ground connections to the
cruise control module cruise control module. Using the manufacturer
Wiring harness fault - approved diagnostic system, complete a LIN
short circuit to network integrity test
ground, short circuit Refer to the electrical circuit diagrams and
to power, open check the LIN network between the cruise
circuit, high control module and instrument panel cluster
resistance control module
Switch fault If no circuit faults are present, check and
Internal module fault install new switch as required. Clear DTC and
retest
If DTC persists, check and install new cruise
control module. Refer to the warranty policy
and procedures manual, or determine if any
prior approval programme is in operation,
prior to the installation of a new
module/component

B112B- Steering Wheel Loss of LIN Refer to the electrical circuit diagrams and
87 Module - Missing communication with check the power and ground connections to the
message steering wheel steering wheel module. Using the
module manufacturer approved diagnostic system,
Wiring harness fault - complete a LIN network integrity test
short circuit to Refer to the electrical circuit diagrams and
ground, short circuit check the LIN network between the steering
to power, open wheel module and instrument panel cluster
circuit, high control module
resistance If no circuit faults are present, check and
Switch fault install new switch as required. Clear DTC and
Internal module fault retest
If DTC persists, check and install new steering
wheel module. Refer to the warranty policy
and procedures manual, or determine if any
prior approval programme is in operation,
prior to the installation of a new
module/component

B115C- Transfer fuel pump - Fluid leak or seal Check transfer fuel pump for leak/seal failure
7A Fluid leak or seal failure
failure
B1A85- Ambient light sensor Wiring harness fault - Refer to electrical circuit diagrams and check
11 - Circuit short to short circuit to ground the ambient light sensor circuit for short circuit
ground Sensor fault to ground. Repair wiring harness as required.
Clear DTC and retest
Check and install new sensor as required.
Clear DTC and retest
B1A85- Ambient light sensor Wiring harness fault - Refer to electrical circuit diagrams and check
15 - Circuit short to short circuit to power, the ambient light sensor circuit for short circuit
battery or open open circuit, high to power, open circuit, high resistance. Repair
resistance wiring harness as required. Clear DTC and
Sensor fault retest
Check and install new sensor as required.
Clear DTC and retest

B1B01- Key transponder - Operator only cycles Ensure all keys to be programmed are
00 Number of keys one key during available
stored below programming Check power and ground supplies to
minimum number Instrument cluster, instrument cluster, start control unit. Clear
required start control unit or DTC and retest
key loses power or Check and replace faulty key as required
circuit failure during Check CAN network for
programming noise/electromagnetic compatibility related
Faulty key issues. Ensure that the vehicle is away from
Unable to programme sources of electromagnetic interference prior
key due to to clearing DTCs and retesting
noise/electromagnetic
compatibility related
issues

B1B01- Key transponder - Error following start Re-synchronize ID by re-configuring the start
05 System programming control unit control unit as a new module
failures replacement Refer to the electrical circuit diagrams and
Start control unit fault check the power and ground connections to the
Instrument cluster start control unit and instrument cluster
fault Refer to the electrical circuit diagrams and
LIN fault check the LIN network between the start
control unit and instrument cluster

B1B01- Key transponder - Instrument cluster Refer to the electrical circuit diagrams and
51 Not programmed fault check the power and ground connections to the
Start control unit fault start control unit and the instrument cluster
LIN fault Refer to the electrical circuit diagrams and
Faulty key check the LIN network between the start
Attempted to control unit and instrument cluster. Clear DTC
programme a non- and retest
default key Ensure new keys are from a known good
source

B1B01- Key transponder - Un-programmed key Confirm correct keys are being used
55 Not configured inserted in start
control unit
Non-default key
inserted during key
programming

B1B01- Key transponder - Instrument cluster Refer to the electrical circuit diagrams and
62 Signal compare fault check the power and ground connections to the
failure Start control unit fault start control unit and the instrument cluster
Incorrect module Check correct instrument cluster/start control
installed (instrument unit modules are installed
cluster/start control Re-synchronize ID by re-configuring the start
unit) control unit as a new module
Error during or Check CAN network for
following the module interference/electromagnetic compatibility
ID check routine related issues. Ensure that the vehicle is away
Noise/electromagnetic from sources of electromagnetic interference
compatibility related prior to clearing DTCs and retesting
issues

B1B01- Key transponder - Instrument cluster Refer to the electrical circuit diagrams and
64 Signal plausibility fault check the power and ground connections to the
failure Start control unit fault start control unit and the instrument cluster
LIN fault Refer to the electrical circuit diagrams and
Key fault check the LIN network between the start
Error occurred during control unit and instrument cluster. Clear DTC
key programming and retest
Confirm correct key operation
Re-run key programming

B1B01- Key transponder - Instrument cluster Refer to the electrical circuit diagrams and
67 Signal incorrect after fault check the ignition, power and ground
event Key fault connections to the start control unit and the
Start control unit fault instrument cluster
LIN fault Refer to the electrical circuit diagrams and
Another key in close check the LIN network between the start
proximity control unit and instrument cluster. Clear DTC
Attempted to and retest
programme a non Confirm single key operation
default key Confirm correct key operation
Instrument panel Ensure new keys are from a known good
cluster cold source
initialisation whilst in Check for intermittent power and ground at
ignition-on state, instrument cluster
without key being If no wiring, electrical or key fault evident,
present in the start determine customer transponder key usage and
control unit advise customer of correct starting sequence
Race condition caused
by closing driver door
and pressing start
button within a small
time window
Passive key search
function from last
door closed and key
inserted in the start
control unit

B1B01- Key transponder - Instrument cluster Refer to the electrical circuit diagrams and
87 Missing message fault check the ignition, power and ground
Start control unit fault connections to the start control unit and the
LIN fault instrument cluster
Refer to the electrical circuit diagrams and
check the LIN network between the start
control unit and instrument cluster. Clear DTC
and retest

B1B33- Target I.D. transfer - Engine control Refer to the electrical circuit diagrams and
05 System programming module fault check the power and ground connections to the
failures Instrument cluster engine control module and instrument cluster
fault Using the manufacturer approved diagnostic
CAN fault system, complete a CAN network integrity
Engine control test. Refer to the electrical circuit diagrams
module or instrument and check the CAN network between the
cluster incorrectly engine control module and instrument cluster.
configured Clear DTC and retest
Re-synchronise ID by re-configuring the
instrument cluster as a new module

B1B33- Target I.D. transfer - Engine control Refer to the electrical circuit diagrams and
62 Signal compare module fault check the power and ground connections to the
failure Instrument cluster engine control module and instrument cluster
fault Using the manufacturer approved diagnostic
CAN fault system, complete a CAN network integrity
Incorrect module test. Refer to the electrical circuit diagrams
installed (Engine and check the CAN network between the
control engine control module and instrument cluster.
module/instrument Clear DTC and retest
cluster) Check correct engine control module and
Module ID instrument cluster installed
synchronisation error Re-synchronise module ID by reconfiguring
following re- the instrument cluster as a new module
programming Check CAN network for
Noise/electromagnetic interference/electromagnetic compatibility
compatibility related related issues. Ensure that the vehicle is away
error from sources of electromagnetic interference
prior to clearing DTCs and retesting

B1B33- Target I.D. transfer - Engine control Refer to the electrical circuit diagrams and
64 Signal plausibility module fault check the power and ground connections to the
failure Instrument cluster engine control module and instrument cluster
fault Using the manufacturer approved diagnostic
CAN fault system, complete a CAN network integrity
Steering column lock test. Refer to the electrical circuit diagrams
status incomplete and check the CAN network between the
Race condition caused engine control module and instrument cluster.
by closing driver door Clear DTC and retest
and pressing start Check steering column lock operation
button within a small If no wiring or electrical fault evident, advise
time window customer of correct starting sequence

B1B33- Target I.D. transfer - Engine control Refer to the electrical circuit diagrams and
87 Missing message module fault check the power and ground connections to the
Instrument cluster engine control module and instrument cluster
fault Using the manufacturer approved diagnostic
CAN fault system, complete a CAN network integrity
Low battery voltage test. Refer to the electrical circuit diagrams
and check the CAN network between the
engine control module and instrument cluster.
Clear DTC and retest
Check battery is in fully charged and
serviceable condition, refer to the battery care
manual
B1C32- Steering column tilt Tilt motion Check mechanical functions of steering
77 solenoid - mechanical fault column and solenoid pin
Commanded position Wiring harness fault - Refer to electrical circuit diagrams and check
not reachable short circuit to the tilt solenoid and switch circuits for short
ground, short circuit circuit to ground, short circuit to power, open
to power, open circuit, high resistance. Repair wiring harness
circuit, high as required. Clear DTC and retest
resistance If no circuit faults are present, check and
Switch fault install new switch as required. Clear DTC and
retest

B1C32- Steering column tilt Tilt motion Check mechanical functions of steering
94 solenoid - mechanical fault column and solenoid pin
Unexpected operation Wiring harness fault - Refer to electrical circuit diagrams and check
short circuit to the tilt solenoid and switch circuits for short
ground, short circuit circuit to ground, short circuit to power, open
to power, open circuit, high resistance. Repair wiring harness
circuit, high as required. Clear DTC and retest
resistance If no circuit faults are present, check and
Switch fault install new switch as required. Clear DTC and
retest

B1C33- Steering column tilt Wiring harness fault - Refer to electrical circuit diagrams and check
12 feedback signal - short circuit to power the tilt feedback circuits for short circuit to
Circuit shorted to power. Repair wiring harness as required.
battery Clear DTC and retest

B1C33- Steering column tilt Wiring harness fault - Refer to electrical circuit diagrams and check
14 feedback signal - short circuit to the tilt feedback circuits for short circuit to
Circuit short to ground, open circuit, ground, open circuit, high resistance. Repair
ground or open high resistance wiring harness as required. Clear DTC and
retest

B1C34- Steering column Telescope motion Check mechanical functions of column and
77 telescope solenoid - mechanical fault solenoid pin
Commanded position Wiring harness fault - Refer to electrical circuit diagrams and check
not reachable short circuit to the telescope solenoid and switch circuits for
ground, short circuit short circuit to ground, short circuit to power,
to power, open open circuit, high resistance. Repair wiring
circuit, high harness as required. Clear DTC and retest
resistance If no circuit faults are present, check and
Solenoid fault install new solenoid or switch as required.
Switch fault Clear DTC and retest

B1C34- Steering column Telescope motion Check mechanical functions of column and
94 telescope solenoid - mechanical fault solenoid pin
Unexpected operation Wiring harness fault - Refer to electrical circuit diagrams and check
short circuit to the telescope solenoid and switch circuits for
ground, short circuit short circuit to ground, short circuit to power,
to power, open open circuit, high resistance. Repair wiring
circuit, high harness as required. Clear DTC and retest
resistance If no circuit faults are present, check and
Solenoid fault install new solenoid or switch as required.
Switch fault Clear DTC and retest

B1C35- Steering column Wiring harness fault - Refer to electrical circuit diagrams and check
12 telescope feedback short circuit to power the telescope feedback circuits for short circuit
signal - Circuit to power. Repair wiring harness as required.
shorted to battery Clear DTC and retest

B1C35- Steering column Wiring harness fault - Refer to electrical circuit diagrams and check
14 telescope feedback short circuit to the telescope feedback circuits for short circuit
signal - Circuit short ground, open circuit, to ground, open circuit, high resistance. Repair
to ground or open high resistance wiring harness as required. Clear DTC and
retest

B1C36- Steering column Wiring harness fault - Refer to electrical circuit diagrams and check
11 tilt/telescope switch - short circuit to ground the steering column tilt/telescope switch
Circuit short to Switch fault circuits for short circuit to ground. Repair
ground wiring harness as required. Clear DTC and
retest
If no circuit faults are present, check and
install new switch as required. Clear DTC and
retest

B1C48- Flash to pass switch - Wiring harness fault - Refer to electrical circuit diagrams and check
11 Circuit short to short circuit to ground the flash to pass switch circuits for short
ground Switch fault circuit to ground. Repair wiring harness as
required. Clear DTC and retest
If no circuit faults are present, check and
install new switch as required. Clear DTC and
retest

B1C48- Flash to pass switch - Wiring harness fault - Refer to electrical circuit diagrams and check
15 Circuit short to short circuit to power, the flash to pass switch circuits for short
battery or open open circuit, high circuit to power, open circuit, high resistance.
resistance Repair wiring harness as required. Clear DTC
Switch fault and retest
If no circuit faults are present, check and
install new switch as required. Clear DTC and
retest

B1C53- Front wiper Wiring harness fault - Refer to electrical circuit diagrams and check
11 intermittent data - short circuit to ground the switch intermittent data circuit for short
Circuit short to Switch fault circuit to ground. Repair wiring harness as
ground required. Clear DTC and retest
If no circuit faults are present, check and
install new switch as required. Clear DTC and
retest

B1C53- Front wiper Wiring harness fault - Refer to electrical circuit diagrams and check
15 intermittent data - short circuit to power, the switch intermittent data circuit for short
Circuit short to open circuit, high circuit to power, open circuit, high resistance.
battery or open resistance Repair wiring harness as required. Clear DTC
Switch fault and retest
If no circuit faults are present, check and
install new switch as required. Clear DTC and
retest

B1D36- Turn indicator switch Wiring harness fault - Refer to electrical circuit diagrams and check
11 - Circuit short to short circuit to ground the turn switch circuits for short circuit to
ground Switch fault ground. Repair wiring harness as required.
Clear DTC and retest
If no circuit faults are present, check and
install new switch as required. Clear DTC and
retest

B1D36- Turn indicator switch Wiring harness fault - Refer to electrical circuit diagrams and check
15 - Circuit short to short circuit to power, the turn switch circuits for short circuit to
battery or open open circuit, high power, open circuit, high resistance. Repair
resistance wiring harness as required. Clear DTC and
Switch fault retest
If no circuit faults are present, check and
install new switch as required. Clear DTC and
retest

B1D37- Wiper switch Wiring harness fault - Refer to electrical circuit diagrams and check
11 connection circuit - short circuit to ground the wiper switch connection circuits for short
Circuit short to Switch fault circuit to ground. Repair wiring harness as
ground required. Clear DTC and retest
If no circuit faults are present, check and
install new switch as required. Clear DTC and
retest

B1D37- Wiper switch Wiring harness fault - Refer to electrical circuit diagrams and check
15 connection circuit - short circuit to power, the wiper switch connection circuits for short
Circuit short to open circuit, high circuit to power, open circuit, high resistance.
battery or open resistance Repair wiring harness as required. Clear DTC
Switch fault and retest
If no circuit faults are present, check and
install new switch as required. Clear DTC and
retest

C004A- Brake Lining Wear Wiring harness fault - Refer to electrical circuit diagrams and check
11 Sensor - Circuit short short circuit to ground the brake linings and wear sensing circuit for
to ground Brake linings sensor short circuit to ground. Repair wiring harness
fault as required. Clear DTC and retest
If no circuit faults are present, check and
install new sensor as required. Clear DTC and
retest

C004A- Brake Lining Wear Wiring harness fault - Refer to electrical circuit diagrams and check
15 Sensor - Circuit short short circuit to power, the brake linings and wear sensing circuit for
to battery or open open circuit, high short circuit to power, open circuit, high
resistance resistance. Repair wiring harness as required.
Brake linings sensor Clear DTC and retest
fault If no circuit faults are present, check and
install new sensor as required. Clear DTC and
retest

C1110- Power steering Invalid variable Using the manufacturer approved diagnostic
64 calibration data - assistance power system, re-configure the instrument cluster as
Signal plausibility steering calibration new. Reload variable assistance power
failure loaded steering calibration data

P0610- Control Module Central junction box Configure the central junction box using the
55 Vehicle Options incorrectly configured manufacturer's approved diagnostic system
Error - Not
configured
P0635- Power steering Wiring harness fault - Refer to electrical circuit diagrams and check
11 control circuit - short circuit to ground the power steering control circuits for short
Circuit short to Variable assistance circuit to ground. Repair wiring harness as
ground power steering required. Clear DTC and retest
actuator fault If no circuit faults are present, check and
install new variable assistance power steering
actuator as required. Clear DTC and retest

P0635- Power steering Wiring harness fault - Refer to electrical circuit diagrams and check
12 control circuit - short circuit to power the power steering control circuits for short
Circuit short to Variable assistance circuit to power. Repair wiring harness as
battery power steering required. Clear DTC and retest
actuator fault If no circuit faults are present, check and
install new variable assistance power steering
actuator as required. Clear DTC and retest

P0635- Power steering Wiring harness fault - Refer to electrical circuit diagrams and check
13 control circuit - open circuit, high the power steering control circuits for open
Circuit open resistance circuit, high resistance. Repair wiring harness
Variable assistance as required. Clear DTC and retest
power steering If no circuit faults are present, check and
actuator fault install new variable assistance power steering
actuator as required. Clear DTC and retest

P0635- Power steering Wiring harness fault - Refer to electrical circuit diagrams and check
22 control circuit - short circuit to the power steering actuator control circuits for
Signal amplitude > ground, short circuit short circuit to ground, short circuit to power,
maximum to power, open open circuit, high resistance. Repair wiring
circuit, high harness as required. Clear DTC and retest
resistance Refer to the electrical circuit diagrams and
CAN fault check the power and ground connections to the
Internal fault within instrument cluster. Using the manufacturer
instrument cluster approved diagnostic system, complete a CAN
network integrity test. Clear DTC and retest
If fault persists, check and install a new
instrument cluster. Refer to the warranty
policy and procedures manual, or determine if
any prior approval programme is in operation,
prior to the installation of a new
module/component

P0635- Power steering Internal fault within Refer to the electrical circuit diagrams and
44 control circuit - Data instrument cluster check for intermittent faults on the power and
memory failure module ground connections to the instrument cluster.
Repair wiring harness as required. Clear DTC
and retest
If fault persists, check and install a new
instrument cluster. Refer to the warranty
policy and procedures manual, or determine if
any prior approval programme is in operation,
prior to the installation of a new
module/component

U0001- High speed CAN High speed CAN Refer to the electrical circuit diagrams and
88 communication Bus - failure - bus off check the high speed CAN bus for short circuit
Bus off to ground, short circuit to power, open circuit,
high resistance

U0010- Medium speed CAN Medium speed CAN Refer to the electrical circuit diagrams and
88 communication Bus - failure - bus off check the medium speed CAN bus for short
Bus off circuit to ground, short circuit to power, open
circuit, high resistance

U0100- Lost communication Loss of CAN Refer to the electrical circuit diagrams and
00 with ECM/PCM A - communication with check the power and ground connections to the
No sub type engine control module engine control module
information Using the manufacturer approved diagnostic
system, complete a CAN network integrity
test. Refer to the electrical circuit diagrams
and check the CAN network between the
engine control module and the instrument
cluster
Check the engine control module for related
DTCs and refer to the relevant DTC index

U0101- Lost communication Loss of CAN Refer to the electrical circuit diagrams and
00 with TCM - No sub communication with check the power and ground connections to the
type information transmission control transmission control module
module Using the manufacturer approved diagnostic
system, complete a CAN network integrity
test. Refer to the electrical circuit diagrams
and check the CAN network between the
transmission control module and the
instrument cluster
Check the transmission control module for
related DTCs and refer to the relevant DTC
index

U0103- Lost communication Loss of CAN Refer to the electrical circuit diagrams and
00 with Gear Shift communication with check the power and ground connections to the
Module - No sub type transmission shift transmission shift module
information module Using the manufacturer approved diagnostic
system, complete a CAN network integrity
test. Refer to the electrical circuit diagrams
and check the CAN network between the
transmission shift module and the instrument
cluster
Check the transmission shift module for
related DTCs and refer to the relevant DTC
index

U0104- Lost communication Loss of CAN Refer to the electrical circuit diagrams and
00 with cruise control communication with check the power and ground connections to the
module - No sub type speed control module speed control module
information Using the manufacturer approved diagnostic
system, complete a CAN network integrity
test. Refer to the electrical circuit diagrams
and check the CAN network between the
speed control module and the instrument
cluster
Check the speed control module for related
DTCs and refer to the relevant DTC index

U0121- Lost communication Loss of CAN Refer to the electrical circuit diagrams and
00 with Anti-lock Brake communication with check the power and ground connections to the
System (ABS) ABS control module ABS control module
control module - No Using the manufacturer approved diagnostic
sub type information system, complete a CAN network integrity
test. Refer to the electrical circuit diagrams
and check the CAN network between the ABS
control module and the instrument cluster
Check the ABS control module for related
DTCs and refer to the relevant DTC index

U0126- Lost Communication Loss of CAN Refer to the electrical circuit diagrams and
00 With Steering Angle communication with check the power and ground connections to the
Sensor Module - No steering angle sensor steering angle sensor module
sub type information module Using the manufacturer approved diagnostic
system, complete a CAN network integrity
test. Refer to the electrical circuit diagrams
and check the CAN network between the
steering angle sensor module and the
instrument cluster
Check the steering angle sensor module for
related DTCs and refer to the relevant DTC
index

U0127- Lost communication Loss of CAN Refer to the electrical circuit diagrams and
00 with Tire Pressure communication with check the power and ground connections to the
Monitor Module - No tire pressure monitor tire pressure monitor module
sub type information module Using the manufacturer approved diagnostic
system, complete a CAN network integrity
test. Refer to the electrical circuit diagrams
and check the CAN network between the tire
pressure monitor module and the instrument
cluster
Check the tire pressure monitor module for
related DTCs and refer to the relevant DTC
index

U0128- Lost communication Loss of CAN Refer to the electrical circuit diagrams and
00 with Park Brake communication with check the power and ground connections to the
control module - No the park brake control park brake control module
sub type information module Using the manufacturer approved diagnostic
system, complete a CAN network integrity
test. Refer to the electrical circuit diagrams
and check the CAN network between the park
brake control module and the instrument
cluster
Check the park brake control module for
related DTCs and refer to the relevant DTC
index

U0139- Lost communication Loss of Refer to the electrical circuit diagrams and
00 with suspension communication with check the power and ground connections to the
control module 'B' - adaptive damping adaptive damping control module. Using the
No sub type control module manufacturer approved diagnostic system,
information complete a CAN network integrity test. Refer
to the electrical circuit diagrams and check the
CAN network between the adaptive damping
control module and the instrument cluster.
Check the adaptive damping control module
for related DTCs and refer to the relevant DTC
index
Check adaptive damping control module for
DTCs and refer to DTC index. Refer to
electrical circuit diagrams and check the CAN
circuits, check power and ground supplies to
the adaptive damping control module

U0140- Lost communication Loss of CAN Refer to the electrical circuit diagrams and
00 with Body Control communication with check the power and ground connections to the
Module - No sub type central junction box central junction box
information Using the manufacturer approved diagnostic
system, complete a CAN network integrity
test. Refer to the electrical circuit diagrams
and check the CAN network between the
central junction box and the instrument cluster
Check the central junction box for related
DTCs and refer to the relevant DTC index

U0142- Lost communication Loss of CAN Refer to the electrical circuit diagrams and
00 with Body Control communication with check the power and ground connections to the
Module B - No sub rear junction box rear junction box
type information Using the manufacturer approved diagnostic
system, complete a CAN network integrity
test. Refer to the electrical circuit diagrams
and check the CAN network between the rear
junction box and the instrument cluster
Check the rear junction box for related DTCs
and refer to the relevant DTC index

U0151- Lost communication Loss of CAN Refer to the electrical circuit diagrams and
00 with Restraints communication with check the power and ground connections to the
Control Module - No restraints control restraints control module
sub type information module Using the manufacturer approved diagnostic
system, complete a CAN network integrity
test. Refer to the electrical circuit diagrams
and check the CAN network between the
restraints control module and the instrument
cluster
Check the restraints control module for related
DTCs and refer to the relevant DTC index

U0156- Lost communication Loss of CAN Refer to the electrical circuit diagrams and
00 with Information communication with check the power and ground connections to the
Centre A - No sub information and information and entertainment control module
type information entertainment control Using the manufacturer approved diagnostic
module system, complete a CAN network integrity
test. Refer to the electrical circuit diagrams
and check the CAN network between the
information and entertainment control module
and the instrument cluster
Check the information and entertainment
control module for related DTCs and refer to
the relevant DTC index

U0164- Lost communication Loss of CAN Refer to the electrical circuit diagrams and
00 with HVAC control communication with check the power and ground connections to the
module - No sub type climate control climate control module
information module Using the manufacturer approved diagnostic
system, complete a CAN network integrity
test. Refer to the electrical circuit diagrams
and check the CAN network between the
climate control module and the instrument
cluster
Check the climate control module for related
DTCs and refer to the relevant DTC index

U017E- Lost Communication Loss of CAN Refer to the electrical circuit diagrams and
00 with Seatbelt communication with check the power and ground connections to the
Pretensioner module driver seatbelt driver seatbelt pretensioner module
'A' - No sub type pretensioner module Using the manufacturer approved diagnostic
information system, complete a CAN network integrity
test. Refer to the electrical circuit diagrams
and check the CAN network between the
driver seatbelt pretensioner module and the
instrument cluster
Check the driver seatbelt pretensioner module
for related DTCs and refer to the relevant DTC
index

U017F- Lost Communication Loss of CAN Refer to the electrical circuit diagrams and
00 with Seatbelt communication with check the power and ground connections to the
Pretensioner module passenger seatbelt passenger seatbelt pretensioner module
'B' - No sub type pretensioner module Using the manufacturer approved diagnostic
information system, complete a CAN network integrity
test. Refer to the electrical circuit diagrams
and check the CAN network between the
passenger seatbelt pretensioner module and the
instrument cluster
Check the passenger seatbelt pretensioner
module for related DTCs and refer to the
relevant DTC index

U0199- Lost communication Loss of CAN Refer to the electrical circuit diagrams and
00 with Door Control communication with check the power and ground connections to the
Module 'A' - No sub driver's door control driver's door control module
type information module Using the manufacturer approved diagnostic
system, complete a CAN network integrity
test. Refer to the electrical circuit diagrams
and check the CAN network between the
driver's door control module and the
instrument cluster
Check the driver's door control module for
related DTCs and refer to the relevant DTC
index

U0200- Lost communication Loss of CAN Refer to the electrical circuit diagrams and
00 with Door Control communication with check the power and ground connections to the
Module 'B' - No sub passenger door passenger door control module
type information control module Using the manufacturer approved diagnostic
system, complete a CAN network integrity
test. Refer to the electrical circuit diagrams
and check the CAN network between the
passenger door control module and the
instrument cluster
Check the passenger door control module for
related DTCs and refer to the relevant DTC
index

U0206- Lost communication Loss of CAN Refer to the electrical circuit diagrams and
00 with folding Top communication with check the power and ground connections to the
control module - No convertible roof convertible roof control module
sub type information control module Using the manufacturer approved diagnostic
system, complete a CAN network integrity
test. Refer to the electrical circuit diagrams
and check the CAN network between the
convertible roof control module and the
instrument cluster
Check the convertible roof control module for
related DTCs and refer to the relevant DTC
index

U0208- Lost communication Loss of CAN Refer to the electrical circuit diagrams and
00 With Driver Seat communication with check the power and ground connections to the
Module - No sub type driver's seat control driver's seat control module
information module Using the manufacturer approved diagnostic
system, complete a CAN network integrity
test. Refer to the electrical circuit diagrams
and check the CAN network between the
driver's seat control module and the instrument
cluster
Check the driver's seat control module for
related DTCs and refer to the relevant DTC
index

U0209- Lost communication Loss of CAN Refer to the electrical circuit diagrams and
00 with Passenger Seat communication with check the power and ground connections to the
Control Module - No passenger seat control passenger seat control module
sub type information module Using the manufacturer approved diagnostic
system, complete a CAN network integrity
test. Refer to the electrical circuit diagrams
and check the CAN network between the
passenger seat control module and the
instrument cluster
Check the passenger seat control module for
related DTCs and refer to the relevant DTC
index

U0214- Lost communication Loss of CAN Refer to the electrical circuit diagrams and
00 with Remote communication with check the power and ground connections to the
Function Actuation - keyless vehicle keyless vehicle module
No sub type module Using the manufacturer approved diagnostic
information system, complete a CAN network integrity
test. Refer to the electrical circuit diagrams
and check the CAN network between the
keyless vehicle module and the instrument
cluster
Check the keyless vehicle module for related
DTCs and refer to the relevant DTC index

U0241- Lost communication Loss of CAN Refer to the electrical circuit diagrams and
00 with Headlamp communication with check the power and ground connections to the
Control Module 'A' - headlamp control headlamp control module
No sub type module Using the manufacturer approved diagnostic
information system, complete a CAN network integrity
test. Refer to the electrical circuit diagrams
and check the CAN network between the
headlamp control module and the instrument
cluster
Check the headlamp control module for
related DTCs and refer to the relevant DTC
index

U0250- Lost communication Loss of CAN Refer to the electrical circuit diagrams and
00 with Impact communication with check the power and ground connections to the
Classification System pedestrian protection pedestrian protection module
Module - No sub type module Using the manufacturer approved diagnostic
information system, complete a CAN network integrity
test. Refer to the electrical circuit diagrams
and check the CAN network between the
pedestrian protection module and the
instrument cluster
Check the pedestrian protection module for
related DTCs and refer to the relevant DTC
index

U0256- Lost communication Loss of CAN Refer to the electrical circuit diagrams and
00 with Front Controls communication with check the power and ground connections to the
Interface Module A - integrated control integrated control panel
No sub type panel Using the manufacturer approved diagnostic
information system, complete a CAN network integrity
test. Refer to the electrical circuit diagrams
and check the CAN network between the
integrated control panel and the instrument
cluster
Check the integrated control panel for related
DTCs and refer to the relevant DTC index

U0300- Internal control Central junction box Re-configure the central junction box using
00 module software car configuration data the manufacturer approved diagnostic system.
incompatibility - No is not compatible with Clear DTCs and re-test
sub type information the instrument cluster If fault persists, check and install a new
instrument cluster. Refer to the warranty
policy and procedures manual, or determine if
any prior approval programme is in operation,
prior to the installation of a new
module/component

U0402- Invalid data received Invalid data received Check the transmission control module for
68 from Transmission from transmission related DTCs and refer to the relevant DTC
Control Module - control module index
Algorithm based
failures/events
information
U2004- Auxiliary switch Wiring harness fault - Refer to electrical circuit diagrams and check
11 pack - Circuit short to short circuit to ground the auxiliary switch pack signal circuit for
ground Switch pack fault short circuit to ground. Repair wiring harness
as required. Clear DTC and retest
If no circuit faults are present, check and
install new switch pack as required. Clear
DTC and retest

U2004- Auxiliary switch Wiring harness fault - Refer to electrical circuit diagrams and check
15 pack - Circuit short to short circuit to power, the auxiliary switch pack signal circuit for
power or open open circuit, high short circuit to power, open circuit, high
resistance resistance. Repair wiring harness as required.
Switch pack fault Clear DTC and retest
If no circuit faults are present, check and
install new switch pack as required. Clear
DTC and retest

U3000- Control module - Instrument cluster Clear DTC and retest. If fault persists, check
46 Calibration/parameter internal fault - corrupt and install a new instrument cluster. Refer to
memory failure non-volatile memory the warranty policy and procedures manual, or
determine if any prior approval programme is
in operation, prior to the installation of a new
module/component

U3000- Control module - Instrument cluster Clear DTC and retest. If fault persists, check
49 Internal electronic internal fault - and install a new instrument cluster. Refer to
failure ROM/EEPROM the warranty policy and procedures manual, or
checksum failure determine if any prior approval programme is
in operation, prior to the installation of a new
module/component

U3000- Control module - Not Incorrect car Re-configure the central junction box using
55 configured configuration data the manufacturer approved diagnostic system.
received Clear DTC and re-test
If fault persists, check and install a new
instrument cluster. Refer to the warranty
policy and procedures manual, or determine if
any prior approval programme is in operation,
prior to the installation of a new
module/component

U3000- Control module - Car configuration Re-configure the central junction box using
87 Missing message parameter not the manufacturer approved diagnostic system.
received Clear DTC and re-test
Check instrument cluster for DTCs and refer
to the DTC index
Using the manufacturer approved diagnostic
system, complete a CAN network integrity
test. Refer to the electrical circuit diagrams
and check the CAN network between the
central junction box and the instrument cluster
U3002- Vehicle Identification Vehicle/component Install original module, check for DTCs and
81 Number - Invalid mis-match. Corrupt refer to relevant DTC index
serial data received VIN data being
transmitted, module
previously installed to
other vehicle

U3003- Battery voltage - Circuit voltage < 9 Refer to relevant section of workshop manual
16 Circuit voltage below volts threshold and battery care manual. Check battery state of
threshold charge and starting/charging system
performance

U3003- Battery voltage - Circuit voltage > 16 Refer to relevant section of workshop manual
17 Circuit voltage above volts threshold and battery care manual. Check battery state of
threshold charge and starting/charging system
performance

U3003- Battery voltage - Signal compare Refer to relevant section of workshop manual
62 Signal compare failure and battery care manual. Check battery state of
failure Instrument cluster charge and starting/charging system
voltage differs more performance. Check logic power supply circuit
than ±2V compared to from central junction box to instrument cluster
central electronics Refer to electrical circuit diagrams and check
module voltage the power and ground supply circuits to the
module. Repair wiring harness as required.
Clear DTC and retest
Published: 21-Jul-2014

2012.0 XF (X250), 100-00

General Information

Diagnostic Trouble Code Index - DTC: Integrated


Audio Module (ACM) (G1426805)
DESCRIPTION AND OPERATION
Integrated Audio Module (ACM)
CAUTION:

Diagnosis by substitution from a donor vehicle is NOT acceptable. Substitution of control modules does not
guarantee confirmation of a fault, and may also cause additional faults in the vehicle being tested and/or the donor
vehicle

NOTES:

If the control module or a component is suspect and the vehicle remains under manufacturer warranty, refer to
the Warranty Policy and Procedures manual, or determine if any prior approval programme is in operation,
prior to the installation of a new module/component.

Generic scan tools may not read the codes listed, or may read only 5-digit codes. Match the 5 digits from the
scan tool to the first 5 digits of the 7-digit code listed to identify the fault (the last 2 digits give extra
information read by the manufacturer-approved diagnostic system)

When performing voltage or resistance tests, always use a digital multimeter accurate to three decimal places
and with a current calibration certificate. When testing resistance, always take the resistance of the digital
multimeter leads into account

Check and rectify basic faults before beginning diagnostic routines involving pinpoint tests

Inspect connectors for signs of water ingress, and pins for damage and/or corrosion

If diagnostic trouble codes are recorded and, after performing the pinpoint tests, a fault is not present, an
intermittent concern may be the cause. Always check for loose connections and corroded terminals

Where an 'on demand self-test' is referred to, this can be accessed via the 'diagnostic trouble code monitor' tab
on the manufacturers approved diagnostic system

Check DDW for open campaigns. Refer to the corresponding bulletins and SSMs which may be valid for the
specific customer complaint and carry out the recommendations as required.

The table below lists all Diagnostic Trouble Codes (DTCs) that could be logged in the Integrated Audio Module, for
additional diagnosis and testing information refer to the relevant diagnosis and testing section For additional
information, refer to: Information and Entertainment System (415-00 Information and Entertainment System -
General Information, Diagnosis and Testing).

DTC Description Possible Causes Action


B117A- Backup Microphone Refer to the electrical circuit diagrams and check the
11 Microphone - circuit short to microphone circuit for short to ground. Repair wiring and
Circuit short ground retest
to ground
B117A- Backup Microphone Refer to the electrical circuit diagrams and check the
13 Microphone - circuit open circuit microphone circuit for open circuit. Repair wiring and
Circuit open retest

B119F- GPS Antenna Global Positioning Check Global Positioning System antenna is connected to
11 - Circuit short System antenna the integrated audio module. Refer to the electrical circuit
to ground not connected to diagrams and check the antenna circuit for short to
integrated audio ground. Repair wiring and retest
module
Global Positioning
System antenna
circuit short to
ground

B119F- GPS Antenna Global Positioning NOTE:


13 - Circuit open System antenna
not connected to This DTC may be stored even though no fault condition is
integrated audio present and should be ignored unless the customer has reported a
module navigation system concern. Clear the DTC and retest. Verify the
Global Positioning customer concern prior to diagnosis
System antenna
circuit open circuit Check Global Positioning System antenna is connected to
the integrated audio module. Refer to the electrical circuit
diagrams and check the antenna circuit for open circuit.
Repair wiring and retest

B11A3- Gyroscope - Internal fault with Refer to the electrical circuit diagrams and check power
49 Internal gyroscope, not supply and ground to integrated audio module. Repair
electronic plausible wiring as required. Clear DTC and recheck. If DTC
failures compared to remains suspect integrated audio module, refer to the
steering angle data warranty policy and procedures manual if a
module/component is suspect

B121C- Hard Drive - Internal fault with Refer to the electrical circuit diagrams and check power
13 Circuit open communication supply and ground to integrated audio module. Repair
with hard drive wiring as required. Clear DTC and recheck. If DTC
remains suspect integrated audio module, refer to the
warranty policy and procedures manual if a
module/component is suspect

B121C- Hard Drive - Internal fault with Refer to the electrical circuit diagrams and check power
49 Internal hard drive supply and ground to integrated audio module. Repair
electronic wiring as required. Clear DTC and recheck. If DTC
failures remains suspect integrated audio module, refer to the
warranty policy and procedures manual if a
module/component is suspect

B1252- USB Port - No Universal Refer to the electrical circuit diagrams and check power
09 Component Serial Bus supply and ground to integrated audio module. Check
failures function Universal Serial Bus circuits. Repair wiring as required.
Clear DTC and recheck. If DTC remains suspect
integrated audio module, refer to the warranty policy and
procedures manual if a module/component is suspect

B1252- USB Port - Excessive current NOTE:


19 Circuit drawn by a
current above universal serial If this DTC is logged, this suggests that the universal serial bus
threshold bus device/cable port has been overloaded, by a portable device or faulty cable
Universal serial
bus device internal Confirm universal serial bus port operation, and using the
failure manufacturer approved diagnostic system, check the
Universal serial integrated audio module for related DTCs and refer to the
bus device cable relevant DTC index
internal failure Disconnect all the universal serial bus connected devices.
Close all the doors and lock the vehicle, wait for a few
minutes (to shut down the media orientated system
transport ring). Restart the vehicle and check if the
universal serial bus operation has recovered
Using the manufacturer approved diagnostic system, clear
the DTCs and retest. Advise the customer of the use of
faulty devices/cables. Some devices will draw more
current when charging such as iPads and can cause this
DTC to log. This is not a permanent fault

B1296- Navigation Navigation map NOTE:


4A Map Data - does not match the
Incorrect market of the This DTC may be stored even though no fault condition is
component vehicle present and should be ignored unless the customer has reported a
installed navigation system concern. Clear the DTC and retest. Verify the
customer concern prior to diagnosis

Update map data as required

B12A0- Auxiliary Auxiliary input Refer to the electrical circuit diagrams and check
11 Input - circuit detected Auxiliary input circuits. If no faults found suspect the
Circuit short short to ground integrated audio module, refer to the warranty policy and
to ground procedures manual if a module/component is suspect

B12A0- Auxiliary Auxiliary input Refer to the electrical circuit diagrams and check
13 Input General circuit detected Auxiliary input circuits. If no faults found suspect the
- Circuit open open circuit integrated audio module, refer to the warranty policy and
procedures manual if a module/component is suspect

B1A56- Antenna - AM/FM antenna Refer to the electrical circuit diagrams and check AM/FM
11 Circuit short circuit short to antenna circuits. If no faults found suspect the integrated
to ground ground audio module, refer to the warranty policy and procedures
manual if a module/component is suspect

B1A56- Antenna - AM/FM antenna Refer to the electrical circuit diagrams and check AM/FM
13 Circuit open circuit open circuit antenna circuits. If no faults found suspect the integrated
audio module, refer to the warranty policy and procedures
manual if a module/component is suspect

B1D50- Digital Disk Mechanical fault Perform basic visual inspection for foreign matter inside
07 Player - disk player. Remove foreign matter if possible. If no
Mechanical objects are found suspect integrated audio module
failures
B1D55- Antenna#2 - FM/TMC antenna Refer to the electrical circuit diagrams and check
11 Circuit short circuit short to FM/Traffic Message Channel antenna circuits. If no faults
to ground ground found suspect the integrated audio module, refer to the
warranty policy and procedures manual if a
module/component is suspect
B1D55- Antenna#2 - FM/Traffic Refer to the electrical circuit diagrams and check
13 Circuit open Message Channel FM/Traffic Message Channel antenna circuits. If no faults
antenna circuit found suspect the integrated audio module, refer to the
open circuit warranty policy and procedures manual if a
module/component is suspect

B1D57- Antenna#4 Vehicle NOTE:


11 Circuit - Information and
Circuit short Communication Vehicle Information and Communication System (VICS) is a
to ground System beacon type of Traffic Message Channel system used in the Japan
antenna short to market only
ground
Check Vehicle Information and Communication System
beacon antenna is connected to the integrated audio
module. Refer to the electrical circuit diagrams and check
Vehicle Information and Communication System beacon
antenna circuits. If no faults found suspect the integrated
audio module, refer to the warranty policy and procedures
manual if a module/component is suspect

B1D57- Antenna#4 Vehicle NOTE:


13 Circuit - Information and
Circuit open Communication Vehicle Information and Communication System (VICS) is a
System beacon type of Traffic Message Channel system used in the Japan
antenna circuit market only
open circuit
Check Vehicle Information and Communication System
beacon antenna is connected to the integrated audio
module. Refer to the electrical circuit diagrams and check
Vehicle Information and Communication System beacon
antenna circuits. If no faults found suspect the integrated
audio module, refer to the warranty policy and procedures
manual if a module/component is suspect

B1D78- Auxiliary Auxiliary #1 input Refer to the electrical circuit diagrams and check
11 Input - circuit short to Auxiliary input #1 circuits. If no faults found suspect the
Circuit short ground integrated audio module, refer to the warranty policy and
to ground procedures manual if a module/component is suspect

B1D78- Auxiliary Auxiliary #1 input Refer to the electrical circuit diagrams and check
13 Input - circuit open circuit Auxiliary input #1 circuits. If no faults found suspect the
Circuit open integrated audio module, refer to the warranty policy and
procedures manual if a module/component is suspect

B1D79- Microphone Microphone #1 Refer to the electrical circuit diagrams and check
11 Input - circuit short to microphone #1 circuits. If no faults found suspect the
Circuit short ground integrated audio module, refer to the warranty policy and
to ground procedures manual if a module/component is suspect

B1D79- Microphone Microphone #1 Refer to the electrical circuit diagrams and check
13 Input - circuit open circuit microphone #1 circuits. If no faults found suspect the
Circuit open integrated audio module, refer to the warranty policy and
procedures manual if a module/component is suspect

P150E- Electronic Control module Check cooling fan operation using manufacturers
00 Control cooling fan signal approved diagnostic tool
Module line detected high
Cooling Fan
Circuit - No
sub type
information
U2005- Vehicle Speed signal NOTE:
62 Speed - broadcast on
Signal MOST is not This DTC may be stored even though no fault condition is
compare received by the present and should be ignored unless the customer has reported a
failure integrated audio navigation system concern. Clear the DTC and retest. Verify the
module. Module customer concern prior to diagnosis
can calculate
speed from Global Check Anti-Lock Brake Control Module for related DTCs
Positioning and refer to the relevant DTC index. Check power supply
System data and and ground supplies to module. Perform a network
this registers as a integrity check using the manufacturers diagnostic system.
signal compare Check MOST ring for breaks. If no faults found suspect
failure integrated audio module, refer to the warranty policy and
procedures manual if a module/component is suspect

U200D- Control Output to Refer to the electrical circuit diagrams and check the
11 Module amplifier circuit output to amplifier circuit. Repair wiring as required and
Output Power short to ground retest the system. If the DTC is still present suspect the
A - Circuit integrated audio module, refer to the warranty policy and
short to procedures manual if a module/component is suspect
ground
U200D- Control Output to Refer to the electrical circuit diagrams and check the
13 Module amplifier circuit output to amplifier circuit. Repair wiring as required and
Output Power open circuit retest the system. If the DTC is still present suspect the
A - Circuit integrated audio module, refer to the warranty policy and
open procedures manual if a module/component is suspect

U2100- Initial Central Car Refer to the electrical circuit diagrams and check the
00 Configuration Configuration file power and ground connections to the module. Using the
Not not received by manufacturer approved diagnostic system, complete a
Complete - Integrated Audio network integrity test. Refer to the electrical circuit
No sub type Module diagrams and check the circuits between the integrated
information audio module and the touch screen display. Check the
MOST ring between the integrated audio module and the
touch screen display. Program the integrated audio module
using the manufacturer approved diagnostic system

U2101- Control Incorrect NOTE:


00 Module component
Configuration installed Only applicable to the Japanese market - This DTC may be
Incompatible Vehicle not stored even though no fault condition is present and should be
- No sub type configured ignored unless the customer has reported an information and
information correctly entertainment system concern. Clear the DTC and retest. Verify
the customer concern prior to diagnosis

Check/configure the car configuration using the approved


diagnostic system

U2200- Control General checksum Clear the DTC and retest. If the problem persists, renew
41 Module failure/internal the module. Refer to the warranty policy and procedures
Configuration memory failure manual if a module is suspect
Memory
Corrupt -
General
checksum
failure
U3000- Control General checksum Clear the DTC and retest. If the problem persists, renew
41 Module - failure the module. Refer to the warranty policy and procedures
General manual if a module is suspect
checksum
failure
U3000- Control Internal software Reprogram the module using the manufacturers approved
45 Module - failure diagnostic system. Clear the DTC and retest. If the DTC
Program remains suspect the integrated audio module, refer to the
memory warranty policy and procedures manual if a module is
failure suspect

U3000- Control Mismatch between NOTE:


46 Module - local configuration
Calibration / file and This DTC may be stored even though no fault condition is
parameter application present and should be ignored unless the customer has reported
memory software an information and entertainment system concern. Clear the
failure DTC and retest. Verify the customer concern prior to diagnosis

Reprogram the module using the manufacturer approved


diagnostic system. Clear the DTC and retest. If the DTC
remains suspect the integrated audio module, refer to the
warranty policy and procedures manual if a module is
suspect

U3000- Control Internal electronic Clear the DTC and retest. If the problem persists, renew
49 Module - failure the module. Refer to the warranty policy and procedures
Internal manual if a module is suspect
electronic
failure
U3000- Control Incorrect hardware Check installed hardware is correct, install new hardware
4A Module - or software as required. Check software version is correct for
Incorrect detected hardware and vehicle configuration. Reprogram modules
component using the manufacturers diagnostic system as required
installed
U3000- Control Hardware Allow vehicle to cool before performing any diagnostic
98 Module - overheated steps. Move vehicle into shade and operate climate control
Component on a cool setting. When vehicle has cooled down check
or system cooling fan operates and ventilation ducts are not
over obstructed. Clear the DTC and retest the system. If the
temperature DTC remains suspect the integrated control module, refer
to the warranty policy and procedures manual if a module
is suspect

U3003- Battery Signal compare Check vehicle battery and charging system. Refer to the
62 Voltage - failure relevant section in the workshop manual. Refer to the
Signal Battery supply electrical circuit diagrams and check the power and
compare voltage below a ground supply circuits to the modules
failure recognized value
Published: 04-May-2014

2012.0 XF (X250), 100-00

General Information

Diagnostic Trouble Code Index - DTC: Integrated


Control Panel (FCIMB) (G1426806)
DESCRIPTION AND OPERATION
Integrated Control Panel (FCIMB)
CAUTION:

Diagnosis by substitution from a donor vehicle is NOT acceptable. Substitution of control modules does not
guarantee confirmation of a fault, and may also cause additional faults in the vehicle being tested and/or the donor
vehicle

NOTES:

If the control module or a component is suspect and the vehicle remains under manufacturer warranty, refer to
the warranty policy and procedures manual, or determine if any prior approval programme is in operation,
prior to the installation of a new module/component

Generic scan tools may not read the codes listed, or may read only 5-digit codes. Match the 5 digits from the
scan tool to the first 5 digits of the 7-digit code listed to identify the fault (the last 2 digits give extra
information read by the manufacturer-approved diagnostic system)

When performing voltage or resistance tests, always use a digital multimeter accurate to three decimal places
and with a current calibration certificate. When testing resistance, always take the resistance of the digital
multimeter leads into account

Check and rectify basic faults before beginning diagnostic routines involving pinpoint tests

Inspect connectors for signs of water ingress, and pins for damage and/or corrosion

If DTCs are recorded and, after performing the pinpoint tests, a fault is not present, an intermittent concern
may be the cause. Always check for loose connections and corroded terminals

Where an 'on demand self-test' is referred to, this can be accessed via the 'DTC monitor' tab on the
manufacturers approved diagnostic system

Check DDW for open campaigns. Refer to the corresponding bulletins and SSMs which may be valid for the
specific customer complaint and carry out the recommendations as needed

The table below lists all diagnostic trouble codes (DTCs) that could be logged in the integrated control panel, for
additional diagnosis and testing information refer to the relevant diagnosis and testing section. For additional
information, refer to: Information and Entertainment System (415-00 Information and Entertainment System -
General Information, Diagnosis and Testing).

DTC Description Possible Causes Action


U0010- Medium Speed Medium speed Clear DTC and retest
88 CAN CAN network - Refer to the electrical circuit diagrams and check the
Communication short circuit to power and ground connections to the module. Using
Bus - Bus off ground, short the manufacturer approved diagnostic system,
circuit to power, complete a CAN network integrity test. Refer to the
open circuit, high electrical circuit diagrams and check the CAN
resistance network

U0140- Lost CAN network - Clear DTC and retest


00 Communication failure between Refer to the electrical circuit diagrams and check the
With Central integrated control power and ground connections to the central junction
Junction Box - No panel and central box. Using the manufacturer approved diagnostic
sub type junction box system, complete a CAN network integrity test. Refer
information to the electrical circuit diagrams and check the CAN
network between the integrated control panel and the
central junction box

U0300- Internal Control Signal Clear DTC and retest. Check/amend the car
00 Module Software configuration file configuration file using the manufacturer approved
Incompatibility - incorrect or diagnostic system. Using the manufacturer approved
No sub type corrupt diagnostic system, update the integrated control panel
information Integrated control software as required
panel installed to If DTC remains, check and install a new integrated
wrong vehicle control panel, as required. Refer to the warranty
Integrated control policy and procedures manual, or determine if any
panel internal prior approval programme is in operation, prior to the
fault installation of a new module

U2013- Switch Pack - Fascia switch Refer to the electrical circuit diagrams and check the
11 Circuit short to pack circuit - fascia switch pack circuit for short circuit to ground.
ground short circuit to Clear DTC and retest
ground If no circuit faults are present, check and install new
Fascia switch fascia switch pack as required. Clear DTC and retest
pack fault If DTC remains, check and install a new integrated
Integrated control control panel, as required. Refer to the warranty
panel internal policy and procedures manual, or determine if any
fault prior approval programme is in operation, prior to the
installation of a new module

U2013- Switch Pack - Fascia switch Refer to the electrical circuit diagrams and check the
15 Circuit short to pack circuit - fascia switch pack circuit for short circuit to power,
battery or open short circuit to open circuit, high resistance. Clear DTC and retest
power, open If no circuit faults are present, check and install new
circuit, high fascia switch pack as required. Clear DTC and retest
resistance If DTC remains, check and install a new integrated
Fascia switch control panel, as required. Refer to the warranty
pack fault policy and procedures manual, or determine if any
Integrated control prior approval programme is in operation, prior to the
panel internal installation of a new module
fault

U201A- Control Module Integrated control Clear DTC and retest. If DTC remains, download and
57 Main Calibration panel calibration install complete set of integrated control panel
Data - files incorrect or software
Invalid/incomplete corrupt Clear DTC and retest. If fault persists, check and
software Software failure install a new integrated control panel, as required.
component Integrated control Refer to the warranty policy and procedures manual,
panel internal or determine if any prior approval programme is in
fault operation, prior to the installation of a new module
U2101- Control Module Car configuration Using the manufacturer approved diagnostic system,
00 Configuration file parameter check the car configuration file parameters match the
Incompatible - No mismatch - vehicle setup
sub type invalid/incomplete Check the correct fascia switch pack is fitted. Replace
information configuration as necessary
Incorrect fascia
switch pack fitted
Published: 17-Apr-2014

2012.0 XF (X250), 100-00

General Information

Diagnostic Trouble Code Index - DTC: Occupant


Classification System (OCS) (G1426808)
DESCRIPTION AND OPERATION
Occupant Classification System (OCS)
CAUTION:

Diagnosis by substitution from a donor vehicle is NOT acceptable. Substitution of control modules does not
guarantee confirmation of a fault, and may also cause additional faults in the vehicle being tested and/or the donor
vehicle

NOTES:

It is advisable not to use a cellular phone or to have a cellular phone in close proximity when working on the
restraints control module or associated systems

Given the legal implications of a restraints system failure, harness repairs to Air Bag module circuits are not
acceptable. Where the text refers to "REPAIR the circuit", this will normally mean the replacement of a
harness.

If the control module or a component is suspect and the vehicle remains under manufacturer warranty, refer to
the Warranty Policy and Procedures manual, or determine if any prior approval programme is in operation,
prior to the installation of a new module/component.

Generic scan tools may not read the codes listed, or may read only 5-digit codes. Match the 5 digits from the
scan tool to the first 5 digits of the 7-digit code listed to identify the fault (the last 2 digits give extra
information read by the manufacturer-approved diagnostic system)

Check and rectify basic faults before beginning diagnostic routines involving pinpoint tests

Inspect connectors for signs of water ingress, and pins for damage and/or corrosion

If diagnostic trouble codes are recorded and, after performing the pinpoint tests, a fault is not present, an
intermittent concern may be the cause. Always check for loose connections and corroded terminals

Where an 'on demand self-test' is referred to, this can be accessed via the 'diagnostic trouble code monitor' tab
on the manufacturers approved diagnostic system

Check DDW for open campaigns. Refer to the corresponding bulletins and SSMs which may be valid for the
specific customer complaint and carry out the recommendations as required.

The table below lists all diagnostic trouble codes (DTCs) that could be logged in the occupant classification system,
for additional diagnosis and testing information refer to the relevant diagnosis and testing section. For additional
information, refer to: Airbag and Safety Belt Pretensioner Supplemental Restraint System (501-20B Supplementary
Restraint System, Diagnosis and Testing).

DTC Description Possible Causes Action


B1193- Crash Event Crash event Clear diagnostic trouble code and re-test
53 Storage Full occurred
and Locked -
Deactivated
B1A54- Occupant Belt General Clear diagnostic trouble code and re-test. If the problem
01 Tension Sensor electrical persists, check and install a new safety belt tension sensor as
- General failure required. Refer to the warranty policy and procedures
Electrical manual, or determine if any prior approval programme is in
Failure operation, prior to the installation of a new
module/component

B1A54- Occupant Belt General Refer to the electrical circuit diagrams and check safety belt
02 Tension Sensor signal failure tension and mat pressure sensor circuits for short to each
- General signal other
failure
B1A54- Occupant Belt Safety belt Refer to the electrical circuit diagrams and check safety belt
11 Tension Sensor tension tension sensor voltage reference and signal circuits for short
- Circuit short sensor to ground
to ground voltage
reference or
signal circuit
- short to
ground

B1A54- Occupant Belt Safety belt Refer to the electrical circuit diagrams and check safety belt
12 Tension Sensor tension tension sensor voltage reference and signal circuits for short
- Circuit short sensor to power
to battery voltage
reference or
signal circuit
- short to
power

B1A54- Occupant Belt Safety belt Refer to the electrical circuit diagrams and check safety belt
13 Tension Sensor tension tension sensor voltage reference and signal circuits for open
- Circuit open sensor circuit
voltage
reference or
signal circuit
- open circuit

B1A62- Pressure Sensor General Refer to the electrical circuit diagrams and check safety belt
02 - General signal signal failure tension and mat pressure sensor circuits for short to each
failure other

B1A62- Pressure Sensor Mat pressure Refer to the electrical circuit diagrams and check mat
11 - Circuit short sensor pressure sensor voltage reference and signal circuits for short
to ground voltage to ground
reference or
signal
circuits -
short to
ground

B1A62- Pressure Sensor Mat pressure Refer to the electrical circuit diagrams and check mat
12 - Circuit short sensor pressure sensor voltage reference, ground and signal circuits
to battery voltage for short to power
reference,
ground or
signal
circuits -
short to
power

B1A62- Pressure Sensor Mat pressure Refer to the electrical circuit diagrams and check mat
13 - Circuit open sensor pressure sensor voltage reference and signal circuits for open
voltage circuit
reference or
signal circuit
- open circuit

B1A62- Pressure Sensor Low fluid Check and install new bladder as required. Refer to the
7B - Low fluid level - warranty policy and procedures manual, or determine if any
level bladder prior approval programme is in operation, prior to the
damaged installation of a new module/component

U0001- High Speed Bus off Refer to the electrical circuit diagrams and check CAN
88 CAN network for short, open circuit. Carry out the CAN network
Communication integrity test using the manufacturer approved diagnostic
Bus - Bus off system

U0151- Lost Restraints Refer to the electrical circuit diagrams and check power and
00 Communication control ground supplies to restraints control module. Carry out CAN
With Restraints module network integrity test using the manufacturer approved
Control Module missing diagnostic system
- No sub type message
information
U0300- Internal Control Master car Check correct occupancy seat module is installed for vehicle
00 Module configuration specification. Check rear junction box for related diagnostic
Software file ID does trouble codes and refer to relevant diagnostic trouble code
Incompatibility not index
- No sub type correspond
information
U2016- Control Module Main Check and install a new occupancy seat module as required.
51 Main Software software not Refer to the warranty policy and procedures manual, or
- Not programmed determine if any prior approval programme is in operation,
programmed prior to the installation of a new module/component

U201A- Control Module Main Check and install a new occupancy seat module as required.
51 Main calibration Refer to the warranty policy and procedures manual, or
Calibration data not determine if any prior approval programme is in operation,
Data - Not programmed prior to the installation of a new module/component
programmed
U3000- Control Module Occupancy Check and install a new occupancy seat module as required.
04 - System seat module Refer to the warranty policy and procedures manual, or
Internal internal determine if any prior approval programme is in operation,
Failures electronic prior to the installation of a new module/component
failure

U3000- Control Module This Check the following criteria have all been achieved: Ignition
54 - Missing diagnostic status set to RUN/START. Verify seat is always empty after
calibration trouble code power-up before re-zero is requested. The occupancy seat
is set if a module has gone through the seat assembly plant calibration.
'calibrate No collision event received from the restraints control
occupancy module during the current ignition cycle. No faults present in
seat module the current ignition cycle. The trigger message for calibrate
empty seat empty seat offset has been received from the diagnostic tool.
offset' Occupancy seat module has enough time to begin
routine is classification. Temperature is between 6C (42F) and 36C
requested (97F)
and fails due
to one of the
pre-
conditions to
execute the
routine

U3003- Battery Voltage Circuit Check battery is in fully charged and serviceable condition.
16 - Circuit voltage Check integrity of charging system
voltage below below
threshold threshold

U3003- Battery Voltage Circuit Check battery is in fully charged and serviceable condition.
17 - Circuit voltage Check integrity of charging system
voltage above above
threshold threshold
Published: 12-May-2014

2012.0 XF (X250), 100-00

General Information

Diagnostic Trouble Code Index - DTC: Parking Aid


Module (PAM) (G1406885)
DESCRIPTION AND OPERATION
Parking Aid Control Module (PACM)
CAUTION:

Diagnosis by substitution from a donor vehicle is NOT acceptable. Substitution of control modules does not
guarantee confirmation of a fault, and may also cause additional faults in the vehicle being tested and/or the donor
vehicle

NOTES:

If the control module or a component is suspect and the vehicle remains under manufacturer warranty, refer to
the warranty policy and procedures manual, or determine if any prior approval programme is in operation,
prior to the installation of a new module/component.

Generic scan tools may not read the codes listed, or may read only 5-digit codes. Match the 5 digits from the
scan tool to the first 5 digits of the 7-digit code listed to identify the fault (the last 2 digits give extra
information read by the manufacturer-approved diagnostic system)

When performing voltage or resistance tests, always use a digital multimeter accurate to three decimal places
and with a current calibration certificate. When testing resistance, always take the resistance of the digital
multimeter leads into account

Check and rectify basic faults before beginning diagnostic routines involving pinpoint tests

Inspect connectors for signs of water ingress, and pins for damage and/or corrosion

If diagnostic trouble codes are recorded and, after performing the pinpoint tests, a fault is not present, an
intermittent concern may be the cause. Always check for loose connections and corroded terminals

Where an 'on demand self-test' is referred to, this can be accessed via the 'diagnostic trouble code monitor' tab
on the manufacturers approved diagnostic system

Check DDW for open campaigns. Refer to the corresponding bulletins and SSMs which may be valid for the
specific customer complaint and carry out the recommendations as required

Physical damage to the sensor (impact damage or scratched sensor surface) must NOT be changed under
warranty.

The table below lists all diagnostic trouble codes (DTCs) that could be logged in the Parking Aid Control Module
(PACM). For additional diagnosis and testing information refer to the relevant diagnosis and testing section. For
additional information, refer to: Parking Aid (413-13 Parking Aid, Diagnosis and Testing).

DTC Description Possible Causes Action


B1B36- Front Right Wiring harness Refer to electrical wiring diagrams and check the front
01 Outer Sensor - fault bumper harness for damage/corrosion. Check sensor circuit
General Front right for short circuit to ground, short circuit to power, open
Electrical outer sensor - circuit. Repair or replace any wiring harness as required
Failure Component Check the connector for integrity and damage, then re-
internal failure connect sensor to confirm connection
Using the manufacturers approved diagnostic system clear
the DTC and run the on demand self test
If the problem persists remove the suspect sensor from the
bumper. Inspect the sensor connector for signs of water
ingress/corrosion. Exchange the suspect sensor with
another sensor within the bumper that is not reporting a
fault. Clear the DTC and run the on demand self test to
confirm if the fault code now appears for the new position
of the suspect sensor. Renew the faulty sensor

B1B36- Front Right Wiring harness Refer to electrical wiring diagrams and check the front
12 Outer Sensor - fault bumper harness for damage. Check sensor circuit for short
Circuit short to circuit to power. Repair or replace any wiring harness as
battery required
Check the connector for integrity and damage, then re-
connect sensor to confirm connection
Using the manufacturers approved diagnostic system clear
the DTC and run the on demand self test

B1B36- Front Right Wiring harness Refer to electrical wiring diagrams and check the front
96 Outer Sensor - fault bumper harness for damage/corrosion. Check sensor circuit
Component Front right for short circuit to ground, short circuit to power, open
internal failure outer sensor - circuit. Repair or replace any wiring harness as required
Component Check the connector for integrity and damage, then re-
internal failure connect sensor to confirm connection
Using the manufacturers approved diagnostic system clear
the DTC and run the on demand self test
If the problem persists remove the suspect sensor from the
bumper. Inspect the sensor connector for signs of water
ingress/corrosion. Exchange the suspect sensor with
another sensor within the bumper that is not reporting a
fault. Clear the DTC and run the on demand self test to
confirm if the fault code now appears for the new position
of the suspect sensor. Renew the faulty sensor

B1B38- Front Right Wiring harness Refer to electrical wiring diagrams and check the front
01 Inner Sensor - fault bumper harness for damage/corrosion. Check sensor circuit
General Front right for short circuit to ground, short circuit to power, open
Electrical inner sensor - circuit. Repair or replace any wiring harness as required
Failure Component Check the connector for integrity and damage, then re-
internal failure connect sensor to confirm connection
Using the manufacturers approved diagnostic system clear
the DTC and run the on demand self test
If the problem persists remove the suspect sensor from the
bumper. Inspect the sensor connector for signs of water
ingress/corrosion. Exchange the suspect sensor with
another sensor within the bumper that is not reporting a
fault. Clear the DTC and run the on demand self test to
confirm if the fault code now appears for the new position
of the suspect sensor. Renew the faulty sensor

B1B38- Front Right Wiring harness Refer to electrical wiring diagrams and check the front
12 Inner Sensor - fault bumper harness for damage. Check sensor circuit for short
Circuit short to circuit to power. Repair or replace any wiring harness as
battery required
Check the connector for integrity and damage, then re-
connect sensor to confirm connection
Using the manufacturers approved diagnostic system clear
the DTC and run the on demand self test

B1B38- Front Right Wiring harness Refer to electrical wiring diagrams and check the front
96 Inner Sensor - fault bumper harness for damage/corrosion. Check sensor circuit
Component Front right for short circuit to ground, short circuit to power, open
internal failure inner sensor - circuit. Repair or replace any wiring harness as required
Component Check the connector for integrity and damage, then re-
internal failure connect sensor to confirm connection
Using the manufacturers approved diagnostic system clear
the DTC and run the on demand self test
If the problem persists remove the suspect sensor from the
bumper. Inspect the sensor connector for signs of water
ingress/corrosion. Exchange the suspect sensor with
another sensor within the bumper that is not reporting a
fault. Clear the DTC and run the on demand self test to
confirm if the fault code now appears for the new position
of the suspect sensor. Renew the faulty sensor

B1B40- Front Left Outer Wiring harness Refer to electrical wiring diagrams and check the front
01 Sensor - General fault bumper harness for damage/corrosion. Check sensor circuit
electrical failure Front left outer for short circuit to ground, short circuit to power, open
sensor - circuit. Repair or replace any wiring harness as required
Component Check the connector for integrity and damage, then re-
internal failure connect sensor to confirm connection
Using the manufacturers approved diagnostic system clear
the DTC and run the on demand self test
If the problem persists remove the suspect sensor from the
bumper. Inspect the sensor connector for signs of water
ingress/corrosion. Exchange the suspect sensor with
another sensor within the bumper that is not reporting a
fault. Clear the DTC and run the on demand self test to
confirm if the fault code now appears for the new position
of the suspect sensor. Renew the faulty sensor

B1B40- Front Left Outer Wiring harness Refer to electrical wiring diagrams and check the front
12 Sensor - Circuit fault bumper harness for damage. Check sensor circuit for short
short to battery circuit to power. Repair or replace any wiring harness as
required
Check the connector for integrity and damage, then re-
connect sensor to confirm connection
Using the manufacturers approved diagnostic system clear
the DTC and run the on demand self test

B1B40- Front Left Outer Wiring harness Refer to electrical wiring diagrams and check the front
96 Sensor - fault bumper harness for damage/corrosion. Check sensor circuit
Component Front left outer for short circuit to ground, short circuit to power, open
internal failure sensor - circuit. Repair or replace any wiring harness as required
Component Check the connector for integrity and damage, then re-
internal failure connect sensor to confirm connection
Using the manufacturers approved diagnostic system clear
the DTC and run the on demand self test
If the problem persists remove the suspect sensor from the
bumper. Inspect the sensor connector for signs of water
ingress/corrosion. Exchange the suspect sensor with
another sensor within the bumper that is not reporting a
fault. Clear the DTC and run the on demand self test to
confirm if the fault code now appears for the new position
of the suspect sensor. Renew the faulty sensor

B1B42- Front Left Inner Wiring harness Refer to electrical wiring diagrams and check the front
01 Sensor - General fault bumper harness for damage/corrosion. Check sensor circuit
electrical failure Front left inner for short circuit to ground, short circuit to power, open
sensor - circuit. Repair or replace any wiring harness as required
Component Check the connector for integrity and damage, then re-
internal failure connect sensor to confirm connection
Using the manufacturers approved diagnostic system clear
the DTC and run the on demand self test
If the problem persists remove the suspect sensor from the
bumper. Inspect the sensor connector for signs of water
ingress/corrosion. Exchange the suspect sensor with
another sensor within the bumper that is not reporting a
fault. Clear the DTC and run the on demand self test to
confirm if the fault code now appears for the new position
of the suspect sensor. Renew the faulty sensor

B1B42- Front Left Inner Wiring harness Refer to electrical wiring diagrams and check the front
12 Sensor - Circuit fault bumper harness for damage. Check sensor circuit for short
short to battery circuit to power. Repair or replace any wiring harness as
required
Check the connector for integrity and damage, then re-
connect sensor to confirm connection
Using the manufacturers approved diagnostic system clear
the DTC and run the on demand self test

B1B42- Front Left Inner Wiring harness Refer to electrical wiring diagrams and check the front
96 Sensor - fault bumper harness for damage/corrosion. Check sensor circuit
Component Front left inner for short circuit to ground, short circuit to power, open
internal failure sensor - circuit. Repair or replace any wiring harness as required
Component Check the connector for integrity and damage, then re-
internal failure connect sensor to confirm connection
Using the manufacturers approved diagnostic system clear
the DTC and run the on demand self test
If the problem persists remove the suspect sensor from the
bumper. Inspect the sensor connector for signs of water
ingress/corrosion. Exchange the suspect sensor with
another sensor within the bumper that is not reporting a
fault. Clear the DTC and run the on demand self test to
confirm if the fault code now appears for the new position
of the suspect sensor. Renew the faulty sensor

B1B44- Rear Right Wiring harness Refer to electrical wiring diagrams and check the rear
01 Outer Sensor - fault bumper harness for damage/corrosion. Check sensor circuit
General Rear Right for short circuit to ground, short circuit to power, open
electrical failure Outer Sensor - circuit. Repair or replace any wiring harness as required
Component Check the connector for integrity and damage, then re-
internal failure connect sensor to confirm connection
Using the manufacturers approved diagnostic system clear
the DTC and run the on demand self test
If the problem persists remove the suspect sensor from the
bumper. Inspect the sensor connector for signs of water
ingress/corrosion. Exchange the suspect sensor with
another sensor within the bumper that is not reporting a
fault. Clear the DTC and run the on demand self test to
confirm if the fault code now appears for the new position
of the suspect sensor. Renew the faulty sensor

B1B44- Rear Right Wiring harness Refer to electrical wiring diagrams and check the rear
12 Outer Sensor - fault bumper harness for damage. Check sensor circuit for short
Circuit short to circuit to power. Repair or replace any wiring harness as
battery required
Check the connector for integrity and damage, then re-
connect sensor to confirm connection
Using the manufacturers approved diagnostic system clear
the DTC and run the on demand self test

B1B44- Rear Right Wiring harness Refer to electrical wiring diagrams and check the rear
96 Outer Sensor - fault bumper harness for damage/corrosion. Check sensor circuit
Component Rear Right for short circuit to ground, short circuit to power, open
internal failure Outer Sensor - circuit. Repair or replace any wiring harness as required
Component Check the connector for integrity and damage, then re-
internal failure connect sensor to confirm connection
Using the manufacturers approved diagnostic system clear
the DTC and run the on demand self test
If the problem persists remove the suspect sensor from the
bumper. Inspect the sensor connector for signs of water
ingress/corrosion. Exchange the suspect sensor with
another sensor within the bumper that is not reporting a
fault. Clear the DTC and run the on demand self test to
confirm if the fault code now appears for the new position
of the suspect sensor. Renew the faulty sensor

B1B46- Rear Right Inner Wiring harness Refer to electrical wiring diagrams and check the rear
01 Sensor - General fault bumper harness for damage/corrosion. Check sensor circuit
electrical failure Rear Right for short circuit to ground, short circuit to power, open
Inner Sensor - circuit. Repair or replace any wiring harness as required
Component Check the connector for integrity and damage, then re-
internal failure connect sensor to confirm connection
Using the manufacturers approved diagnostic system clear
the DTC and run the on demand self test
If the problem persists remove the suspect sensor from the
bumper. Inspect the sensor connector for signs of water
ingress/corrosion. Exchange the suspect sensor with
another sensor within the bumper that is not reporting a
fault. Clear the DTC and run the on demand self test to
confirm if the fault code now appears for the new position
of the suspect sensor. Renew the faulty sensor

B1B46- Rear Right Inner Wiring harness Refer to electrical wiring diagrams and check the rear
12 Sensor - Circuit fault bumper harness for damage. Check sensor circuit for short
short to battery circuit to power. Repair or replace any wiring harness as
required
Check the connector for integrity and damage, then re-
connect sensor to confirm connection
Using the manufacturers approved diagnostic system clear
the DTC and run the on demand self test

B1B46- Rear Right Inner Wiring harness Refer to electrical wiring diagrams and check the rear
96 Sensor - fault bumper harness for damage/corrosion. Check sensor circuit
Component Rear Right for short circuit to ground, short circuit to power, open
internal failure Inner Sensor - circuit. Repair or replace any wiring harness as required
Component Check the connector for integrity and damage, then re-
internal failure connect sensor to confirm connection
Using the manufacturers approved diagnostic system clear
the DTC and run the on demand self test
If the problem persists remove the suspect sensor from the
bumper. Inspect the sensor connector for signs of water
ingress/corrosion. Exchange the suspect sensor with
another sensor within the bumper that is not reporting a
fault. Clear the DTC and run the on demand self test to
confirm if the fault code now appears for the new position
of the suspect sensor. Renew the faulty sensor

B1B48- Rear Left Outer Wiring harness Refer to electrical wiring diagrams and check the rear
01 Sensor - General fault bumper harness for damage/corrosion. Check sensor circuit
electrical failure Rear Left for short circuit to ground, short circuit to power, open
Outer Sensor - circuit. Repair or replace any wiring harness as required
Component Check the connector for integrity and damage, then re-
internal failure connect sensor to confirm connection
Using the manufacturers approved diagnostic system clear
the DTC and run the on demand self test
If the problem persists remove the suspect sensor from the
bumper. Inspect the sensor connector for signs of water
ingress/corrosion. Exchange the suspect sensor with
another sensor within the bumper that is not reporting a
fault. Clear the DTC and run the on demand self test to
confirm if the fault code now appears for the new position
of the suspect sensor. Renew the faulty sensor

B1B48- Rear Left Outer Wiring harness Refer to electrical wiring diagrams and check the rear
12 Sensor - Circuit fault bumper harness for damage. Check sensor circuit for short
short to battery circuit to power. Repair or replace any wiring harness as
required
Check the connector for integrity and damage, then re-
connect sensor to confirm connection
Using the manufacturers approved diagnostic system clear
the DTC and run the on demand self test

B1B48- Rear Left Outer Wiring harness Refer to electrical wiring diagrams and check the rear
96 Sensor - fault bumper harness for damage/corrosion. Check sensor circuit
Component Rear Left for short circuit to ground, short circuit to power, open
internal failure Outer Sensor - circuit. Repair or replace any wiring harness as required
Component Check the connector for integrity and damage, then re-
internal failure connect sensor to confirm connection
Using the manufacturers approved diagnostic system clear
the DTC and run the on demand self test
If the problem persists remove the suspect sensor from the
bumper. Inspect the sensor connector for signs of water
ingress/corrosion. Exchange the suspect sensor with
another sensor within the bumper that is not reporting a
fault. Clear the DTC and run the on demand self test to
confirm if the fault code now appears for the new position
of the suspect sensor. Renew the faulty sensor

B1B50- Rear Left Inner Wiring harness Refer to electrical wiring diagrams and check the rear
01 Sensor - General fault bumper harness for damage/corrosion. Check sensor circuit
electrical failure Rear Left Inner for short circuit to ground, short circuit to power, open
Sensor - circuit. Repair or replace any wiring harness as required
Component Check the connector for integrity and damage, then re-
internal failure connect sensor to confirm connection
Using the manufacturers approved diagnostic system clear
the DTC and run the on demand self test
If the problem persists remove the suspect sensor from the
bumper. Inspect the sensor connector for signs of water
ingress/corrosion. Exchange the suspect sensor with
another sensor within the bumper that is not reporting a
fault. Clear the DTC and run the on demand self test to
confirm if the fault code now appears for the new position
of the suspect sensor. Renew the faulty sensor

B1B50- Rear Left Inner Wiring harness Refer to electrical wiring diagrams and check the rear
12 Sensor - Circuit fault bumper harness for damage. Check sensor circuit for short
short to battery circuit to power. Repair or replace any wiring harness as
required
Check the connector for integrity and damage, then re-
connect sensor to confirm connection
Using the manufacturers approved diagnostic system clear
the DTC and run the on demand self test

B1B50- Rear Left Inner Wiring harness Refer to electrical wiring diagrams and check the rear
96 Sensor - fault bumper harness for damage/corrosion. Check sensor circuit
Component Rear Left Inner for short circuit to ground, short circuit to power, open
internal failure Sensor - circuit. Repair or replace any wiring harness as required
Component Check the connector for integrity and damage, then re-
internal failure connect sensor to confirm connection
Using the manufacturers approved diagnostic system clear
the DTC and run the on demand self test
If the problem persists remove the suspect sensor from the
bumper. Inspect the sensor connector for signs of water
ingress/corrosion. Exchange the suspect sensor with
another sensor within the bumper that is not reporting a
fault. Clear the DTC and run the on demand self test to
confirm if the fault code now appears for the new position
of the suspect sensor. Renew the faulty sensor

B1B54- Function LED - Wiring harness Refer to electrical wiring diagrams and check the parking
11 Park Aid - fault aid LED circuit for short circuit to ground. Repair or
Circuit short to Switch/LED - replace any wiring harness as required
ground Component Using the manufacturers approved diagnostic system clear
internal failure the DTC and run the on demand self test. If the problem
persists, suspect the switch/LED

B1B54- Function LED - Wiring harness Refer to electrical wiring diagrams and check the parking
12 Park Aid - fault aid LED circuit for short circuit to power. Repair or replace
Circuit short to Switch/LED - any wiring harness as required
battery Component Using the manufacturers approved diagnostic system clear
internal failure the DTC and run the on demand self test. If the problem
Control persists, suspect the switch/LED
Module -
Component
internal failure

B1B57- Front Sensors Wiring harness Check front and rear bumper harness for signs of damage
11 Power Circuit- fault and security of connections
Circuit short to Control Refer to electrical wiring diagrams and check the parking
ground Module - assist front sensor power circuit and rear sensor power
Component circuit for short circuit to ground. Repair or replace any
internal failure wiring harness as required
Using the manufacturers approved diagnostic system clear
the DTC and run the on demand self test. If the problem
persists, suspect the control module
Cycle the ignition off, then on, to power up parking aid
system and check corrective action

B1B58- Rear Sensors Wiring harness Check rear and front (if front PDC fitted) bumper harness
11 Power Circuit - fault for signs of damage and security of connections
Circuit short to Control Refer to electrical wiring diagrams and check the parking
ground Module - assist rear sensor power circuit and front sensor power
Component circuit (if front PDC fitted) for short circuit to ground.
internal failure Repair or replace any wiring harness as required
Using the manufacturers approved diagnostic system clear
the DTC and run the on demand self test. If the problem
persists, suspect the control module
Cycle the ignition off, then on, to power up parking aid
system and check corrective action

B1C30- Disable Switch - Wiring harness Refer to electrical wiring diagrams and check the parking
73 Actuator stuck fault assist switch and switch circuit. Repair or replace any
closed Control Switch wiring harness as required
- Component Using the manufacturers approved diagnostic system clear
internal failure the DTC and run the on demand self test. If the problem
persists, suspect the control switch
Check the switch function

U0010- Medium Speed Medium speed Refer to the electrical circuit diagrams and check the
00 CAN CAN failure - parking aid control module medium speed CAN bus for
Communication bus off short circuit to ground, short circuit to power, open circuit,
Bus - No sub high resistance, or short circuit between the paired CAN
type information wires
Using the manufacturer approved diagnostic system,
complete a CAN network integrity test
Cycle the ignition off, then on, and check if the DTC is still
logged

U0073- Control Module Control Refer to the electrical circuit diagrams and check the
00 Communication module parking aid control module high speed CAN bus for short
Bus "A" Off - communication circuit to ground, short circuit to power, open circuit, high
No sub type Bus "A" failure resistance, or short circuit between the paired CAN wires
information - bus off Using the manufacturer approved diagnostic system,
complete a CAN network integrity test
Cycle the ignition off, then on, and check if the DTC is still
logged

U0140- Lost Loss of CAN Refer to the electrical circuit diagrams and check the power
00 Communication communication and ground connections to the central junction box. Clear
With Body with central DTC and retest
Control Module junction box Using the manufacturer approved diagnostic system,
- No sub type complete a CAN network integrity test. Refer to the
information electrical circuit diagrams and check the CAN network
between the central junction box and the parking aid
control module

U0142- Lost Loss of CAN Refer to the electrical circuit diagrams and check the power
00 Communication communication and ground connections to the auxiliary junction box. Clear
With Body with auxiliary DTC and retest
Control Module junction box Using the manufacturer approved diagnostic system,
"B" - No sub complete a CAN network integrity test. Refer to the
type information electrical circuit diagrams and check the CAN network
between the central junction box and the parking aid
control module

U0155- Lost Loss of CAN Refer to the electrical circuit diagrams and check the power
00 Communication communication and ground connections to the instrument cluster. Clear
With Instrument with DTC and retest
Panel Cluster instrument Using the manufacturer approved diagnostic system,
(IPC) Control cluster complete a CAN network integrity test. Refer to the
Module - No electrical circuit diagrams and check the CAN network
sub type between the central junction box and the parking aid
information control module

U0300- Internal Control Car Using the manufacturer approved diagnostic system, check
00 Module configuration all other control modules, for related DTCs and refer to the
Software file stored in relevant DTC index
Incompatibility - parking aid Check the components installed on the vehicle were
No sub type control module installed by the factory or a dealer
information does not match Install the original component or a new one as required
the master car
configuration
file
Master car
configuration
file not being
transmitted by
master control
module

U0422- Invalid Data Invalid data Using the manufacturer approved diagnostic system, check
00 Received From received central junction box, for related DTCs and refer to the
Body Control relevant DTC index
Module - No Using the manufacturer approved diagnostic system,
sub type complete a CAN network integrity test
information Cycle the ignition off, then on, and check if the DTC is still
logged
Clear the DTC and re-test

U0423- Invalid Data Invalid data Using the manufacturer approved diagnostic system, check
00 Received From received instrument cluster, for related DTCs and refer to the
Instrument relevant DTC index
Panel Control Using the manufacturer approved diagnostic system,
Module - No complete a CAN network integrity test
sub type Cycle the ignition off, then on, and check if the DTC is still
information logged
Clear the DTC and re-test

U0443- Invalid Data Invalid data Using the manufacturer approved diagnostic system, check
00 Received From received auxiliary junction box, for related DTCs and refer to the
Body Control relevant DTC index
Module "B" - Using the manufacturer approved diagnostic system,
No sub type complete a CAN network integrity test
information Cycle the ignition off, then on, and check if the DTC is still
logged
Clear the DTC and re-test

U2100- Initial Car NOTE:


00 Configuration configuration
Not Complete - file not the After updating the car configuration file, set the ignition to on and
No sub type same as wait 30 seconds before clearing the DTCs
information expected by
the parking aid Using the manufacturer approved diagnostic system, check
control module and update the car configuration file as required. Clear the
DTC and retest

U2101- Control Module Parking aid Using the manufacturer approved diagnostic system check
00 Configuration control module and up-date the car configuration file as required. Clear the
Incompatible - configuration DTC and re-test
No sub type error
information
U3000- Control Module Parking aid Using the manufacturers approved diagnostic system clear
49 - Internal control module the DTC, cycle the ignition off, then on, and check if the
electronic internal failure DTC is still logged
failure If the DTC is still logged suspect the parking aid control
module

U3002- Vehicle VIN Using the manufacturers approved diagnostic system clear
81 Identification Mismatch, the DTC, cycle the ignition off, then on, and check if the
Number - stored VIN DTC is still logged
Invalid serial does not match If the DTC is still logged replace the parking aid control
data received broadcast VIN module

U3003- Battery voltage - Circuit voltage Using the manufacturer approved diagnostic system, check
16 Circuit voltage below central junction box, for related DTCs and refer to the
below threshold threshold relevant DTC index
Check the vehicle charging system performance to ensure
the voltage regulation is correct
Refer to relevant section of workshop manual and battery
care manual. Check battery state of charge and
starting/charging system performance
Refer to the electrical circuit diagrams and check parking
aid control module power and ground circuits for short
circuit to ground, short circuit to power, open circuit
Clear the DTC and retest

U3003- Battery Voltage Circuit voltage Using the manufacturer approved diagnostic system, check
17 - Circuit voltage above central junction box, for related DTCs and refer to the
above threshold threshold relevant DTC index
Check the vehicle charging system performance to ensure
the voltage regulation is correct
Refer to relevant section of workshop manual and battery
care manual. Check battery state of charge and
starting/charging system performance
Refer to the electrical circuit diagrams and check parking
aid control module power and ground circuits for short
circuit to ground, short circuit to power, open circuit
Clear the DTC and retest

U3003- Battery Voltage Signal compare Using the manufacturer approved diagnostic system, check
62 - Signal failure in central junction box, for related DTCs and refer to the
compare failure battery voltage, relevant DTC index
of 2 volts or Check the vehicle charging system performance to ensure
more, between the voltage regulation is correct
parking aid Refer to relevant section of workshop manual and battery
control module care manual. Check battery state of charge and
and central starting/charging system performance
junction box Refer to the electrical circuit diagrams and check parking
aid control module power and ground circuits for short
circuit to ground, short circuit to power, open circuit
Clear the DTC and retest
Published: 17-Apr-2014

2012.0 XF (X250), 100-00

General Information

Diagnostic Trouble Code Index - DTC: Rear


Differential Control Module (RDCM) (G1426811)
DESCRIPTION AND OPERATION
Rear Differential Control Module (RDCM)
CAUTION:

Diagnosis by substitution from a donor vehicle is NOT acceptable. Substitution of control modules does not
guarantee confirmation of a fault, and may also cause additional faults in the vehicle being tested and/or the donor
vehicle

NOTES:

If the control module or a component is suspect and the vehicle remains under manufacturer warranty, refer to
the warranty policy and procedures manual, or determine if any prior approval programme is in operation,
prior to the installation of a new module/component

Generic scan tools may not read the codes listed, or may read only 5-digit codes. Match the 5 digits from the
scan tool to the first 5 digits of the 7-digit code listed to identify the fault (the last 2 digits give extra
information read by the manufacturer-approved diagnostic system)

When performing voltage or resistance tests, always use a digital multimeter accurate to three decimal places
and with a current calibration certificate. When testing resistance, always take the resistance of the digital
multimeter leads into account

Check and rectify basic faults before beginning diagnostic routines involving pinpoint tests

Inspect connectors for signs of water ingress, and pins for damage and/or corrosion

If DTCs are recorded and, after performing the pinpoint tests, a fault is not present, an intermittent concern
may be the cause. Always check for loose connections and corroded terminals

If the rear differential control module, rear differential actuator or the rear differential are replaced, the on
demand self test (ODST) must be carried out to calibrate the components

Check DDW for open campaigns. Refer to the corresponding bulletins and SSMs which may be valid for the
specific customer complaint and carry out the recommendations as needed

The table below lists all diagnostic trouble codes (DTCs) that could be logged in the rear differential control module,
for additional diagnosis and testing information refer to the relevant diagnosis and testing section. For additional
information, refer to: Rear Drive Axle and Differential (205-02 Rear Drive Axle/Differential, Diagnosis and
Testing).

DTC Description Possible Causes Action


P0562- System Voltage Rear differential Check the battery charge condition, refer to the
00 Low - No sub type control module electrical circuit diagrams and check the wiring to
information voltage supply the rear differential control module, repair as
below 9 volts necessary
P0563- System Voltage System voltage Check engine control module for stored DTCs,
00 High - No sub type high (supply suspect charging system fault. Refer to the
information voltage supply electrical circuit diagrams and check, power and
greater than 16 ground circuit for fault
volts)

P0604- Internal Control Rear differential Clear the DTC and retest. If the problem persists,
00 Module Random control module renew the control module. Refer to the warranty
Access Memory internal error policy and procedures manual, or determine if any
(RAM) Error - No prior approval programme is in operation, prior to
sub type the installation of a new module/component
information
P0605- Internal Control Rear differential Clear the DTC and retest. If the problem persists,
00 Module Read Only control module renew the control module. Refer to the warranty
Memory (ROM) internal error policy and procedures manual, or determine if any
Error - No sub type prior approval programme is in operation, prior to
information the installation of a new module/component

P0606- Control Module Watchdog reset - This is a control module internal check DTC. If no
00 Processor - No sub internal control other DTCs are logged and no customer complaint
type information module failure exists, clear/ignore this DTC. If the problem
persists, renew the control module. Refer to the
warranty policy and procedures manual, or
determine if any prior approval programme is in
operation, prior to the installation of a new
module/component

P0607- Control Module Rear differential Clear the DTC and retest. If the problem persists,
00 Performance - No control module renew the control module. Refer to the warranty
sub type internal error - policy and procedures manual, or determine if any
information charge pump prior approval programme is in operation, prior to
voltage below the installation of a new module/component
threshold

P0652- Sensor Reference Position sensor Refer to the electrical circuit diagrams and check
00 Voltage B Circuit supply below 5.7V the differential actuator sensor position circuit,
Low - No sub type Sensor failure repair as necessary. Clear the DTC and retest
information (within actuator) If no circuit problems exist, renew the differential
actuator. Refer to the warranty policy and
procedures manual, or determine if any prior
approval programme is in operation, prior to the
installation of a new module/component

P0653- Sensor Reference Motor position Refer to the electrical circuit diagrams and check
00 Voltage B Circuit sensor supply the differential actuator hall sensor reference
High - No sub type above 8.3 V voltage at the control module or the actuator
information Internal control If voltage is too high, then renew control module.
module failure Refer to the warranty policy and procedures
manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

P0666- PCM / ECM / Internal electronic This is a control module internal check DTC. If no
00 TCM Internal control unit other DTCs are logged and no customer complaint
Temperature temperature sensor exists, clear this DTC and retest. Check the security
Sensor A Circuit - value above 105°C of control module fixings. Check the module
No sub type ground connection. Consider environmental
information conditions before suspecting the control module. If
the problem persists, renew the control module.
Refer to the warranty policy and procedures
manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

P0702- Transmission Implausibility of Check the rear differential oil quantity and
64 Control System differential motor specification. Refer to the relevant section of the
Electrical - Signal temperature sensor workshop manual. Check both temperature sensor
plausibility failure and oil temperature circuits and connectors for damage/water ingress,
sensor readout repair as necessary. Where available, after vehicle
detected has been switched off for at least an hour, use the
Motor or oil manufacturer approved diagnostic system to read
temperature sensor motor temperature and oil temperature sensor
circuit - short values. Temperature difference should be less than
circuit to ground or 25°C. Clear the DTC and retest
power Refer to the electrical circuit diagrams and check
motor temperature sensor and oil sump temperature
sensors and circuit for short circuit to ground, short
circuit to power

P0712- Transmission Fluid Differential Refer to the electrical circuit diagrams and check
00 Temperature actuator internal rear differential actuator motor temperature sensor
Sensor A Circuit temperature sensor circuit for short circuit to ground, open circuit, high
Low - No sub type circuit - open resistance. Clear the DTC and retest. If no circuit
information circuit or short problems exist, renew the differential actuator.
circuit to ground Refer to the warranty policy and procedures
manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

P0713- Transmission Fluid Differential Refer to the electrical circuit diagrams and check
00 Temperature actuator internal the circuit between oil temperature sensor and
Sensor A Circuit temperature sensor control module connector, repair as necessary.
High - No sub type circuit - open Measure oil temperature sensor resistance at control
information circuit or short module connector. Resistance should be less than
circuit to power 10K if oil temp >0°C. If not, suspect oil temp
sensor open-circuit. If no circuit problems exist,
renew the sensor. Refer to the warranty policy and
procedures manual, or determine if any prior
approval programme is in operation, prior to the
installation of a new module/component

P0806- Clutch Position Mismatch of actual Calibrate the clutch using the manufacturer
00 Sensor Circuit and approved diagnostic system. Clear the DTC and
Range/Performance expected/calculated retest
- No sub type actuator position If the problem persists, renew the differential
information Internal differential actuator. Refer to the warranty policy and
actuator error procedures manual, or determine if any prior
approval programme is in operation, prior to the
installation of a new module/component

P0807- Clutch Position Differential Refer to the electrical circuit diagrams and check
00 Sensor Circuit Low actuator internal the differential actuator motor position hall sensor
- No sub type position sensor signal (A or B) circuit for short circuit to ground,
information supply, signal (A open circuit, high resistance, repair as necessary.
or B) circuit - short Clear the DTC and retest. If no circuit problems
circuit to ground, exist, renew the differential actuator. Refer to the
open circuit, high warranty policy and procedures manual, or
resistance determine if any prior approval programme is in
operation, prior to the installation of a new
module/component

P0808- Clutch Position Differential Refer to the electrical circuit diagrams and check
00 Sensor Circuit High actuator internal the differential actuator motor position hall sensor
- No sub type position sensor signal (A or B) circuit for short circuit to power,
information signal (1 or 2) repair as necessary. Clear the DTC and retest. If no
circuit - short circuit problems exist, renew the differential
circuit to power actuator. Refer to the warranty policy and
procedures manual, or determine if any prior
approval programme is in operation, prior to the
installation of a new module/component

P080A- Clutch Position Not Rear differential Using the manufacturer approved diagnostic
00 Learned - No sub control module not system, calibrate the rear differential control
type information calibrated module. Clear the DTC, cycle ignition and retest
Differential clutch If the problem persists, check operation of the
stuck or out of differential actuator motor and renew as necessary.
tolerance If no motor problems exist, renew the rear
differential assembly. Refer to the warranty policy
and procedures manual, or determine if any prior
approval programme is in operation, prior to the
installation of a new module/component

P0894- Transmission Differential Clear the DTC and retest. If the problem persists,
00 Component actuator internal renew the differential actuator. Refer to the
Slipping - No sub magnetic brake is warranty policy and procedures manual, or
type information slipping determine if any prior approval programme is in
operation, prior to the installation of a new
module/component

P0900- Clutch Actuator Differential Refer to the electrical circuit diagrams and check
00 Circuit/Open - No actuator supply rear differential actuator clutch actuation motor
sub type circuit - open circuit for open circuit, high resistance, repair as
information circuit, high necessary
resistance

P0901- Clutch Actuator Differential Refer to the electrical circuit diagrams and check
00 Circuit actuator supply the differential actuator circuit. Check the actuator
Range/Performance circuit - short circuit resistance carefully (a good motor also has a
- No sub type circuit. Both DC low resistance). Repair as necessary
information motor supply leads
are short circuited
together, or H
Bridge overload
detected

P0902- Clutch Actuator Differential Refer to the electrical circuit diagrams and check
00 Circuit Low - No actuator supply the differential actuator circuit for short circuit to
sub type circuit - short ground, repair as necessary
information circuit to ground

P0903- Clutch Actuator Differential Refer to the electrical circuit diagrams and check
00 Circuit High - No actuator supply the differential actuator circuit for short circuit to
sub type circuit - short power, repair as necessary
information circuit to power

P1603- EEPROM Rear differential Clear the DTC and retest. If the problem persists,
00 Malfunction - No control module renew the control module. Refer to the warranty
sub type internal error policy and procedures manual, or determine if any
information prior approval programme is in operation, prior to
the installation of a new module/component

P1783- Transmission Over- Rear differential oil Confirm the customer complaint and vehicle usage
00 temperature sump temperature at the time of DTC event. Check the operation of
Condition - No sub sensor value above the rear differential. Check the rear differential oil
type information 160°C quantity and specification. Refer to the relevant
section of the workshop manual. Clear the DTC and
retest. If the problem persists, suspect an electrical
fault. Check for water ingress into wiring
harness/connectors. Renew the actuator. Refer to
the warranty policy and procedures manual, or
determine if any prior approval programme is in
operation, prior to the installation of a new
module/component

P186A- Differential Lock- Open circuit, high Refer to the electrical circuit diagrams and check
00 up Actuator Brake resistance of the differential actuator circuit for open circuit,
Control Circuit / actuator internal high resistance repair as necessary. Clear the DTC
Open - No sub type magnetic brake and retest. If no circuit problems exist, renew the
information supply leads differential actuator. Refer to the warranty policy
and procedures manual, or determine if any prior
approval programme is in operation, prior to the
installation of a new module/component

P186B- Differential Lock- Short circuit to Refer to the electrical circuit diagrams and check
00 up Actuator Brake ground of both the differential actuator circuit for short circuit to
Control Circuit differential actuator ground, repair as necessary. Clear the DTC and
Low - No sub type internal magnetic retest. If no circuit problems exist, renew the
information brake pins differential actuator. Refer to the warranty policy
and procedures manual, or determine if any prior
approval programme is in operation, prior to the
installation of a new module/component

P186C- Differential Lock- Short circuit to Refer to the electrical circuit diagrams and check
00 up Actuator Brake power of both the differential actuator circuit for short circuit to
Control Circuit differential actuator power, repair as necessary. Clear the DTC and
High - No sub type internal magnetic retest. If no circuit problems exist, renew the
information brake pins differential actuator. Refer to the warranty policy
and procedures manual, or determine if any prior
approval programme is in operation, prior to the
installation of a new module/component

P186D- Clutch Actuator Actuator fault Using the manufacturers approved diagnostic
00 Stuck - No sub type system, calibrate the rear differential control
information module/clutch actuator. Clear the DTC and retest. If
the problem persists, renew the actuator. Refer to
the warranty policy and procedures manual, or
determine if any prior approval programme is in
operation, prior to the installation of a new
module/component

P2742- Transmission Fluid Rear differential oil Refer to the electrical circuit diagrams and check
00 Temperature sump temperature the differential oil temperature sensor circuit for
Sensor B Circuit sensor short circuit short circuit to ground, repair as necessary
Low - No sub type to ground
information
P2743- Transmission Fluid Rear differential oil Refer to the electrical circuit diagrams and check
00 Temperature sump temperature the differential oil temperature sensor circuit for
Sensor B Circuit sensor circuit - short circuit to power, open circuit, high resistance,
High - No sub type short circuit to repair as necessary
information power, open
circuit, high
resistance

P2785- Clutch Actuator Clutch actuator Confirm the customer complaint and vehicle usage
00 Temperature Too temperature sensor at the time of DTC event. Check the operation of
High - No sub type value above 150°C the rear differential. Check the rear differential oil
information - insufficient oil quantity and specification. Refer to the relevant
quantity, incorrect section of the workshop manual. Clear the DTC and
oil specification or retest. If the problem persists, renew the actuator.
internal actuator Refer to the warranty policy and procedures
problem manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

P2787- Clutch Rear differential Confirm the customer complaint and vehicle usage
00 Temperature Too clutch pack at the time of DTC event. Check the operation of
High - No sub type temperature the rear differential. Check the rear differential oil
information (calculated) above quantity and specification. Refer to the relevant
200°C section of the workshop manual. Clear the DTC and
retest. If the problem persists, renew the actuator.
Refer to the warranty policy and procedures
manual, or determine if any prior approval
programme is in operation, prior to the installation
of a new module/component

U0001- High Speed CAN High speed CAN Refer to the electrical circuit diagrams and check
88 Communication - bus off detected the power and ground connections to the module.
Bus off Using the manufacturer approved diagnostic
system, complete a CAN network integrity test.
Refer to the electrical circuit diagrams and check
the CAN network

U0100- Lost Lost Refer to the electrical circuit diagrams and check
00 Communication communication the power and ground connections to the module.
With ECM/PCM with engine control Using the manufacturer approved diagnostic
"A" - No sub type module (CAN bus system, complete a CAN network integrity test.
information circuit fault) Refer to the electrical circuit diagrams and check
the CAN network between the engine control
module and rear differential control module
U0121- Lost Lost Refer to the electrical circuit diagrams and check
00 Communication communication the power and ground connections to the module.
With Anti-Lock with ABS control Using the manufacturer approved diagnostic
Brake System module (CAN bus system, complete a CAN network integrity test.
(ABS) Control circuit fault) Refer to the electrical circuit diagrams and check
Module - No sub the CAN network between the ABS control module
type information and rear differential control module

U0139- Lost Lost Refer to the electrical circuit diagrams and check
00 Communication communication the power and ground connections to the module.
With Suspension with adaptive Using the manufacturer approved diagnostic
Control Module damping module system, complete a CAN network integrity test.
"B" - No sub type (CAN bus circuit Refer to the electrical circuit diagrams and check
information fault) the CAN network between the adaptive damping
module and rear differential control module

U0155- Lost Lost Refer to the electrical circuit diagrams and check
00 Communication communication the power and ground connections to the module.
With Instrument with instrument Using the manufacturer approved diagnostic
Panel Cluster panel cluster system, complete a CAN network integrity test.
Control Module - control module Refer to the electrical circuit diagrams and check
No sub type (CAN bus circuit the CAN network between the instrument panel
information fault) cluster control module and rear differential control
module

U0300- Internal Control Rear differential Check and confirm correct rear differential control
00 Module Software control module not module is installed. If correct, clear DTC, ignition
Incompatibility - configured - off for 5 seconds, ignition on and then check if
No sub type incorrect software DTC reoccurs. If the problem persists, configure
information installed the module using the manufacturer approved
diagnostic system

U0415- Invalid Data Invalid data Refer to the electrical circuit diagrams and check
68 Received From received the power and ground connections to the module.
Anti-Lock Brake Using the manufacturer approved diagnostic
System (ABS) system, complete a CAN network integrity test.
Control Module - Refer to the electrical circuit diagrams and check
Event information the CAN network between the ABS module and
rear differential control module

U043A- Invalid Data Invalid data Check adaptive damping module for stored DTCs
68 Received From received and refer to the relevant DTC index
Suspension Control
Module "B" -
Event information
U1A14- CAN Initialization Rear differential Clear the DTC and retest. If the problem persists,
49 Failure - Internal control module has configure the module using the manufacturers
electronic failure failed the CAN approved diagnostic system. Clear the DTC and
serial data retest
communication If the problem persists, renew the rear differential
software control module. Refer to the warranty policy and
initialization procedures manual, or determine if any prior
Internal control approval programme is in operation, prior to the
module failure installation of a new module/component
Published: 04-May-2014

2012.0 XF (X250), 100-00

General Information

Diagnostic Trouble Code Index - DTC: Rear Junction


Box (BCMB) (G1426812)
DESCRIPTION AND OPERATION
Rear Junction Box (RJB)
CAUTION:

Diagnosis by substitution from a donor vehicle is NOT acceptable. Substitution of control modules does not
guarantee confirmation of a fault, and may also cause additional faults in the vehicle being tested and/or the donor
vehicle

NOTES:

If the control module or a component is suspect and the vehicle remains under manufacturer warranty, refer to
the warranty policy and procedures manual, or determine if any prior approval programme is in operation,
prior to the installation of a new module/component

Generic scan tools may not read the codes listed, or may read only 5-digit codes. Match the 5 digits from the
scan tool to the first 5 digits of the 7-digit code listed to identify the fault (the last 2 digits give extra
information read by the manufacturer-approved diagnostic system)

When performing voltage or resistance tests, always use a digital multimeter accurate to three decimal places
and with a current calibration certificate. When testing resistance, always take the resistance of the digital
multimeter leads into account

Check and rectify basic faults before beginning diagnostic routines involving pinpoint tests

Inspect connectors for signs of water ingress, and pins for damage and/or corrosion

If diagnostic trouble codes are recorded and, after performing the pinpoint tests, a fault is not present, an
intermittent concern may be the cause. Always check for loose connections and corroded terminals

Where an 'on demand self-test' is referred to, this can be accessed via the 'diagnostic trouble code monitor' tab
on the manufacturers approved diagnostic system

Check DDW for open campaigns. Refer to the corresponding bulletins and SSMs which may be valid for the
specific customer complaint and carry out the recommendations as required

The table below lists all diagnostic trouble codes (DTCs) that could be logged in the rear junction box, for additional
diagnosis and testing information refer to the relevant diagnosis and testing section. For additional information, refer
to: Communications Network (418-00 Module Communications Network, Diagnosis and Testing).

DTC Description Possible Causes Action


B100A- Fuel Pump Rear junction box fault Refer to the electrical circuit
51 Authorisation - Not Instrument cluster fault diagrams and check the ignition,
programmed Module ID synchronisation power and ground connections to
error following re- rear junction box and instrument
programming cluster
Low speed CAN fault Using the manufacturer approved
diagnostic system, complete a CAN
network integrity test. Refer to the
electrical circuit diagrams and
check the CAN network between
the rear junction box and the
instrument cluster

B100A- Fuel Pump Rear junction box fault Refer to the electrical circuit
62 Authorisation - Signal Instrument cluster fault diagrams and check the power and
compare failure Low speed CAN fault ground connections to the rear
Incorrect module installed junction box and instrument cluster
(Rear junction box/instrument Using the manufacturer approved
cluster) diagnostic system, complete a CAN
Module ID synchronisation network integrity test. Refer to the
error following re- electrical circuit diagrams and
programming check the CAN network between
the rear junction box and
instrument cluster
Confirm correct rear junction
box/instrument cluster module
installed
Re-synchronise ID by re-
configuring the rear junction box as
a new module

B100A- Fuel Pump Rear junction box fault Refer to the electrical circuit
63 Authorisation - Instrument cluster fault diagrams and check the power and
Circuit/component Low speed CAN fault ground connections to the rear
protection time-out Low battery voltage <9V junction box and instrument cluster
Using the manufacturer approved
diagnostic system, complete a CAN
network integrity test. Refer to the
electrical circuit diagrams and
check the CAN network between
the rear junction box and
instrument cluster. Clear DTC and
retest
Check battery is fully charged and
in serviceable condition, refer to
the battery care manual

B1026- Steering Column Lock Steering column lock will not Refer to the electrical circuit
12 - Circuit short to battery release/will not lock diagrams and check steering
Steering column lock - ground column lock ground circuit for
circuit short circuit to power short to power. Repair wiring
harness as required. Clear DTC and
retest

B10AF- Blower Fan Relay - Blower fan inoperative Refer to the electrical circuit
11 Circuit short to ground Blower fan circuit - Circuit diagrams and check blower fan
BLOWER_MOTOR_SUPPLY circuit - Circuit
- Short circuit to ground BLOWER_MOTOR_SUPPLY -
Blower motor fault For short circuit to ground. Repair
wiring harness as required. Clear
DTC and retest
If no wiring faults are present,
check and install new blower motor
as required. Clear DTC and retest

B10DE- Low Fuel Warning Diesel run-dry switch analogue Refer to the electrical circuit
11 Switch - Circuit short to input circuit - short circuit to diagrams and check diesel run-dry
ground ground switch analogue input circuit for
Switch fault short circuit to ground. Repair
wiring harness as required. Clear
DTC and retest
If no wiring faults are present,
check and install new switch as
required. Clear DTC and retest

B10DE- Low Fuel Warning Diesel run-dry switch analogue Refer to the electrical circuit
15 Switch - Circuit short to input circuit - short circuit to diagrams and check diesel run-dry
battery or open power, open circuit, high switch analogue input circuit for
resistance short circuit to power, open circuit,
Switch fault high resistance. Repair wiring
harness as required. Clear DTC and
retest
If no wiring faults are present,
check and install new switch as
required. Clear DTC and retest

B1112- Park Aid Ignition - Audible park aid inoperative Refer to the electrical circuit
11 Circuit short to ground Parking aid ignition supply diagrams and check parking aid
circuit - short circuit to ground ignition supply circuit for short
circuit to ground. Repair wiring
harness as required. Clear DTC and
retest

B1112- Park Aid Ignition - Audible park aid inoperative Refer to the electrical circuit
15 Circuit short to battery Parking aid ignition supply diagrams and check parking aid
or open circuit - short circuit to power, ignition supply circuit for short
open circuit, high resistance circuit to power, open circuit, high
resistance. Repair wiring harness as
required. Clear DTC and retest

B1115- High Mounted Stop High mounted stop lamp Refer to the electrical circuit
11 Lamp Control - Circuit inoperative diagrams and check high mounted
short to ground High mounted stop lamp stop lamp control circuit for short
control circuit - short circuit to circuit to ground. Repair wiring
ground harness as required. Clear DTC and
retest

B1115- High Mounted Stop High mounted stop lamp Refer to the electrical circuit
15 Lamp Control - Circuit inoperative diagrams and check high mounted
short to battery or open High mounted stop lamp stop lamp control circuit for short
control circuit - short circuit to circuit to power, open circuit, high
power, open circuit, high resistance. Repair wiring harness as
resistance required. Clear DTC and retest

B1116- Left Tail Lamp - Left side tail lamp inoperative Refer to the electrical circuit
11 Circuit short to ground Left side tail lamp control diagrams and check left side tail
circuit - short circuit to ground lamp control circuit for short circuit
to ground. Repair wiring harness as
required. Clear DTC and retest

B1116- Left Tail Lamp - Left side tail lamp inoperative Refer to the electrical circuit
15 Circuit short to battery Left side tail lamp control diagrams and check left side tail
or open circuit - short circuit to power, lamp control circuit for short circuit
open circuit, high resistance to power, open circuit, high
resistance. Repair wiring harness as
required. Clear DTC and retest

B1117- Right Tail Lamp - Right side tail lamp Refer to the electrical circuit
11 Circuit short to ground inoperative diagrams and check right side tail
Right side tail lamp control lamp control circuit for short circuit
circuit - short circuit to ground to ground. Repair wiring harness as
required. Clear DTC and retest

B1117- Right Tail Lamp - Right side tail lamp Refer to the electrical circuit
15 Circuit short to battery inoperative diagrams and check right side tail
or open Right side tail lamp control lamp control circuit for short circuit
circuit - short circuit to power, to power, open circuit, high
open circuit, high resistance resistance. Repair wiring harness as
required. Clear DTC and retest

B111A- Number Plate Lamps - Right or left side licence plate Refer to the electrical circuit
11 Circuit short to ground lamp(s) inoperative diagrams and check right side and
Right or left side licence plate left side licence plate lamp control
lamp control circuits - short circuits for short circuit to ground.
circuit to ground Repair wiring harness as required.
Clear DTC and retest

B111A- Number Plate Lamps - Right or left side licence plate Refer to the electrical circuit
15 Circuit short to battery lamp(s) inoperative diagrams and check right side and
or open Right or left side licence plate left side licence plate lamp control
lamp control circuits - short circuits for short circuit to power,
circuit to power, open circuit, open circuit, high resistance. Repair
high resistance wiring harness as required. Clear
DTC and retest

B111D- Boot/Trunk Motor Luggage compartment lid latch Refer to the electrical circuit
11 Open - Circuit short to inoperative diagrams and check luggage
ground Luggage compartment lid latch compartment lid latch actuator
actuator control circuit - short control circuit for short circuit to
circuit to ground ground. Repair wiring harness as
Luggage compartment lid latch required. Clear DTC and retest
actuator fault If no wiring faults are present,
check and install new luggage
compartment lid latch actuator as
required. Clear DTC and retest

B111D- Boot/Trunk Motor Luggage compartment lid latch Refer to the electrical circuit
15 Open - Circuit short to inoperative diagrams and check luggage
battery or open Luggage compartment lid latch compartment lid latch actuator
actuator control circuit - short control circuit for short to power,
circuit to power, open circuit, open circuit, high resistance. Clear
high resistance DTC and retest
Luggage compartment lid latch If no wiring faults are present,
actuator fault check and install new luggage
compartment lid latch actuator as
required. Clear DTC and retest

B111E- Boot/Trunk Lamps - Luggage compartment lamp Refer to the electrical circuit
11 Circuit short to ground inoperative diagrams and check luggage
Luggage compartment lamp compartment lamp control circuit
control circuit - short circuit to for short circuit to ground. Repair
ground wiring harness as required. Clear
DTC and retest

B111E- Boot/Trunk Lamps - Luggage compartment lamp Refer to the electrical circuit
15 Circuit short to battery inoperative diagrams and check luggage
or open Luggage compartment lamp compartment lamp control circuit
control circuit - short circuit to for short circuit to power, open
power, open circuit, high circuit, high resistance. Repair
resistance wiring harness as required. Clear
DTC and retest

B1123- Restraints Ignition Supplemental restraints system Refer to the electrical circuit
12 Relay - Circuit short to fault diagrams and check restraints
battery Restraints ignition relay ignition relay control circuit for
control circuit - short circuit to short circuit to power. Repair
power wiring harness as required. Clear
Restraints ignition relay fault DTC and retest
If no wiring faults are present,
check and install new rear junction
box as required. Clear DTC and
retest

B1123- Restraints Ignition Supplemental restraints system Refer to the electrical circuit
93 Relay - No operation fault diagrams and check restraints
Restraints ignition relay ignition relay control circuit for
control circuit - short circuit to short circuit to power, open circuit,
power, open circuit, high high resistance. Repair wiring
resistance harness as required. Clear DTC and
Restraints ignition relay may retest
be either stuck open or stuck If no wiring faults are present,
closed check and install new rear junction
box as required. Clear DTC and
retest

B1124- Lamp Fade Control - Interior lamp fade inoperative Refer to the electrical circuit
12 Circuit short to battery Interior lamp fade control diagrams and check interior lamp
circuit - short circuit to power fade control circuit for short circuit
to power. Repair wiring harness as
required. Clear DTC and retest

B113C- Hazard Switch Hazard switch illumination Refer to the electrical circuit
12 Illumination - Circuit inoperative diagrams and check hazard switch
short to battery Hazard switch illumination illumination control circuit for
control circuit - short circuit to short circuit to power. Repair
power wiring harness as required. Clear
DTC and retest

B113E- External Boot/Trunk NOTE: Refer to the electrical circuit


13 Release switch - Circuit diagrams and check external
open This DTC will only set following the luggage compartment lid release
completion of an on demand test switch circuit for open circuit, high
routine (routine 0202h) when circuit resistance. Repair wiring harness as
is open required. Clear DTC and retest

External luggage compartment


lid release switch circuit - open
circuit, high resistance

B113E- External Boot/Trunk External luggage compartment Refer to the electrical circuit
23 Release Switch - Signal lid release switch held down diagrams and check external
stuck low for > 10 seconds luggage compartment lid release
External luggage compartment switch circuit for short circuit to
lid release switch control power. Repair wiring harness as
circuit - short circuit to power required. Clear DTC and retest
Jammed or faulty switch If no wiring faults are present,
check and install new external
luggage compartment lid release
switch as required. Clear DTC and
retest

B11D9- Vehicle Battery - The battery monitoring module Check vehicle has correct battery
49 Internal electronic has detected an internal circuit type and size installed. Install new
failure failure as required
Incorrect battery type or size Using manufacturer approved
installed diagnostic system, verify vehicle
High quiescent current quiescent current draw levels are
Battery worn out or damaged correct using power supply
A temporary battery state diagnostic function. Rectify as
estimation error. The battery required
state estimation is performed Using the Midtronics battery tester
by the battery monitoring and battery care manual check the
system battery is serviceable. Install new
as required
The battery monitoring system will
correct a temporary battery state
estimation error within a reasonable
adaption time. The adaption time is
dependant upon the driving time of
the vehicle and may take a number
of weeks

B11DB- Battery Monitoring Battery monitoring module Disconnect vehicle battery, re-
49 Module - Internal failure connect after 60 seconds, clear
electronic failure DTC and retest
If fault persists, check and install a
new battery monitoring module as
required. Refer to the warranty
policy and procedures manual, or
determine if any prior approval
programme is in operation, prior to
the installation of a new module

B11DB- Battery Monitoring Rear junction box failure Clear DTC and retest. If additional
87 Module - Missing Battery monitoring module DTC B108783 is logged, check and
message connector disconnected/poor install a new rear junction box as
connection required. Refer to the warranty
Battery monitoring module to policy and procedures manual, or
rear junction box local determine if any prior approval
interconnect network circuit - programme is in operation, prior to
open circuit the installation of a new module
Battery monitoring module to If additional DTC B108783 is NOT
battery positive monitor circuit logged, check for good/clean
- open circuit contact at battery monitoring
Battery monitoring module module connector, refer to
failure electrical circuit diagrams and
check local interconnect network
circuit between the battery
monitoring module and rear
junction box. Repair wiring harness
as required. Clear DTC and retest
Refer to electrical circuit diagrams
and check battery monitoring
module to battery positive monitor
circuit for open circuit. Repair
wiring harness as required. Clear
DTC and retest
If DTC remains, check and install a
new battery monitoring module as
required. Refer to the warranty
policy and procedures manual, or
determine if any prior approval
programme is in operation, prior to
the installation of a new module

B123A- Left Front Turn Left front turn signal lamp Refer to electrical circuit diagrams
11 Indicator - Circuit short control circuit - short circuit to and check left front turn signal
to ground ground lamp control circuit for short circuit
to ground. Repair wiring harness as
required. Clear DTC and retest

B123A- Left Front Turn Left front turn signal lamp Refer to electrical circuit diagrams
15 Indicator - Circuit short control circuit - short circuit to and check left front turn signal
to battery or open power, open circuit, high lamp control circuit for short circuit
resistance to power, open circuit, high
resistance. Repair wiring harness as
required. Clear DTC and retest

B123B- Right Front Turn Right front turn signal lamp Refer to electrical circuit diagrams
11 Indicator - Circuit short control circuit - short circuit to and check right front turn signal
to ground ground lamp control circuit for short circuit
to ground. Repair wiring harness as
required. Clear DTC and retest

B123B- Right Front Turn Right front turn signal lamp Refer to electrical circuit diagrams
15 Indicator - Circuit short control circuit - short circuit to and check right front turn signal
to battery or open power, open circuit, high lamp control circuit for short circuit
resistance to power, open circuit, high
resistance. Repair wiring harness as
required. Clear DTC and retest

B1247- Left Rear Turn Left rear turn signal lamp Refer to electrical circuit diagrams
11 Indicator - Circuit short control circuit - short circuit to and check left rear turn signal lamp
to ground ground control circuit for short circuit to
ground. Repair wiring harness as
required. Clear DTC and retest

B1247- Left Rear Turn Left rear turn signal lamp Refer to electrical circuit diagrams
15 Indicator - Circuit short control circuit - short circuit to and check left rear turn signal lamp
to battery or open power, open circuit, high control circuit for short circuit to
resistance power, open circuit, high
resistance. Repair wiring harness as
required. Clear DTC and retest

B1248- Right Rear Turn Right rear turn signal lamp Refer to electrical circuit diagrams
11 Indicator - Circuit short control circuit - short circuit to and check right rear turn signal
to ground ground lamp control circuit for short circuit
to ground. Repair wiring harness as
required. Clear DTC and retest

B1248- Right Rear Turn Right rear turn signal lamp Refer to electrical circuit diagrams
15 Indicator - Circuit short control circuit - short circuit to and check right rear turn signal
to battery or open power, open circuit, high lamp control circuit for short circuit
resistance to power, open circuit, high
resistance. Repair wiring harness as
required. Clear DTC and retest

B1286- Interior Mirror - Circuit Interior mirror power circuit - Refer to electrical circuit diagrams
11 short to ground Circuit EC_GDO_AHB_PWR and check interior mirror power
- short circuit to ground circuit - Circuit
EC_GDO_AHB_PWR - for short
circuit to ground. Repair wiring
harness as required. Clear DTC and
retest

B130B- Right Rear Fog Lamp - Right rear fog lamp control Refer to electrical circuit diagrams
11 Circuit short to ground circuit - short circuit to ground and check right rear fog lamp
control circuit for short circuit to
ground. Repair wiring harness as
required. Clear DTC and retest

B130B- Right Rear Fog Lamp - Right rear fog lamp control Refer to electrical circuit diagrams
15 Circuit short to battery circuit - short circuit to power, and check right rear fog lamp
or open open circuit, high resistance control circuit for short circuit to
power, open circuit, high
resistance. Repair wiring harness as
required. Clear DTC and retest

B130E- Left Rear Fog Lamp - Left rear fog lamp control Refer to electrical circuit diagrams
11 Circuit short to ground circuit - short circuit to ground and check left rear fog lamp control
circuit for short circuit to ground.
Repair wiring harness as required.
Clear DTC and retest

B130E- Left Rear Fog Lamp - Left rear fog lamp control Refer to electrical circuit diagrams
15 Circuit short to battery circuit - short circuit to power, and check left rear fog lamp control
or open open circuit, high resistance circuit for short circuit to power,
open circuit, high resistance. Repair
wiring harness as required. Clear
DTC and retest

B13C2- Front Loss of LIN communication Refer to the electrical circuit


87 Windscreen/Windshield with front diagrams and check the power and
Misting Sensor - windscreen/windshield misting ground connections to the rear
Missing message sensor junction box. Clear diagnostic
Loss of LIN communication trouble code and retest
with battery monitoring system Refer to the electrical circuit
module diagrams and check the LIN
network between the rear junction
box and the front
windscreen/windshield misting
sensor and the LIN network
between the rear junction box and
the battery monitoring system
module. Repair wiring harness as
required. Clear DTC and retest
Check the rear junction box for
additional LIN related diagnostic
trouble codes and refer to the
relevant diagnostic trouble code
index

B13D2- Decklid Tail Lamp Decklid tail lamp control Refer to electrical circuit diagrams
11 Control - Circuit short circuit - short circuit to ground and check decklid lamps control
to ground circuit for short circuit to ground.
Repair wiring harness as required.
Clear DTC and retest

B13D2- Decklid Tail Lamp Decklid tail lamp control Refer to electrical circuit diagrams
15 Control - Circuit short circuit - short circuit to power, and check decklid lamps control
to battery or open open circuit, high resistance circuit for short circuit to power,
open circuit, high resistance. Repair
wiring harness as required. Clear
DTC and retest

B13D5- Rear Window Heater - Heated rear screen inoperative Refer to electrical circuit diagrams
11 Circuit short to ground Heated rear screen control and check heated rear screen
circuit - short circuit to power control circuit for short circuit to
Heated rear screen fault power. Repair wiring harness as
Rear junction box fault required. Clear DTC and retest
If no wiring faults are present and
the rear screen heating element is
continuous and intact, check and
install new rear junction box as
required. Clear DTC and retest
Refer to the warranty policy and
procedures manual, or determine if
any prior approval programme is in
operation, prior to the installation
of a new module/component

B13D5- Rear Window Heater - Heated rear screen inoperative Refer to electrical circuit diagrams
15 Circuit short to battery Heated rear screen control and check heated rear screen
or open circuit - short circuit to power, control circuit for short circuit to
open circuit, high resistance power, open circuit, high
Heated rear screen fault resistance. Repair wiring harness as
Rear junction box fault required. Clear DTC and retest
If no wiring faults are present and
the rear screen heating element is
continuous and intact, check and
install new rear junction box as
required. Clear DTC and retest
Refer to the warranty policy and
procedures manual, or determine if
any prior approval programme is in
operation, prior to the installation
of a new module/component

B1407- Trailer Tow Module - Auxiliary trailer socket Refer to electrical circuit diagrams
87 Missing message connector disconnected/poor and check the LIN circuit between
connection the auxiliary trailer socket and rear
Auxiliary trailer socket to rear junction box for open circuit, high
junction box local interconnect resistance. Repair wiring harness as
network circuit - open circuit, required. Clear DTC and retest
high resistance Refer to electrical circuit diagrams
Auxiliary trailer socket power and check the auxiliary trailer
circuit - open circuit, high socket power circuit for open
resistance circuit, high resistance. Repair
Auxiliary trailer socket failure wiring harness as required. Clear
Rear junction box fault DTC and retest
If no wiring faults are present,
check and install new auxiliary
trailer socket as required. Clear
DTC and retest
If problem persists, check and
install new rear junction box as
required. Clear DTC and retest
Refer to the warranty policy and
procedures manual, or determine if
any prior approval programme is in
operation, prior to the installation
of a new module/component

B140B- Trunk Close Luggage compartment soft Refer to the electrical circuit
11 Mechanism/Actuator close mechanism control diagrams and check luggage
Close Circuit - Circuit circuit - short circuit to ground compartment soft close mechanism
short to ground control circuit for short circuit to
ground. Repair wiring harness as
required. Clear DTC and retest

B140B- Trunk Close Luggage compartment soft Refer to the electrical circuit
12 Mechanism/Actuator close mechanism control diagrams and check luggage
Close Circuit - Circuit circuit - short circuit to power compartment soft close mechanism
short to battery control circuit for short circuit to
power. Repair wiring harness as
required. Clear DTC and retest

B140B- Trunk Close Luggage compartment soft Refer to the electrical circuit
13 Mechanism/Actuator close mechanism control diagrams and check luggage
Close Circuit - Circuit circuit - open circuit, high compartment soft close mechanism
open resistance control circuit for open circuit, high
resistance. Repair wiring harness as
required. Clear DTC and retest

B140C- Trunk Close Luggage compartment soft Refer to the electrical circuit
11 Mechanism/Actuator close reverse mechanism diagrams and check luggage
Reverse Circuit - control circuit - short circuit to compartment soft close reverse
Circuit short to ground ground mechanism control circuit for short
circuit to ground. Repair wiring
harness as required. Clear DTC and
retest

B140C- Trunk Close Luggage compartment soft Refer to the electrical circuit
12 Mechanism/Actuator close reverse mechanism diagrams and check luggage
Reverse Circuit - control circuit - short circuit to compartment soft close reverse
Circuit short to battery power mechanism control circuit for short
circuit to power. Repair wiring
harness as required. Clear DTC and
retest

B140C- Trunk Close Luggage compartment soft Refer to the electrical circuit
13 Mechanism/Actuator close reverse mechanism diagrams and check luggage
Reverse Circuit - control circuit - open circuit, compartment soft close reverse
Circuit open high resistance mechanism control circuit for open
circuit, high resistance. Repair
wiring harness as required. Clear
DTC and retest

B140D- Quiescent Power Infotainment power relay fault Check that the ring break
93 Control Relay #1 - No Infotainment power relay stuck diagnostic fuse is correctly installed
operation open or stuck closed and operational
Check the battery monitoring
system for DTCs and refer to
relevant DTC index. Clear DTC
and retest
If fault persists, check and install a
new rear junction box as required.
Clear DTC and retest
Refer to the warranty policy and
procedures manual, or determine if
any prior approval programme is in
operation, prior to the installation
of a new module/component

B1C55- Horn Relay - Circuit Vehicle alarm horn inoperative Refer to electrical circuit diagrams
12 short to battery Horn control circuit - short and check horn control circuit for
circuit to power short circuit to ground. Repair
Horn relay fault wiring harness as required. Clear
DTC and retest
If no wiring faults are present,
check and install new horn relay as
required. Clear DTC and retest

B1D35- Hazard Switch - Circuit NOTE: Refer to the electrical circuit


13 open diagrams and check hazard switch
This DTC will only set following the circuit for open circuit, high
completion of an on demand test resistance. Repair wiring harness as
routine (routine 0202h) when circuit required. Clear DTC and retest
is open

Hazard switch circuit - open


circuit, high resistance

B1D35- Hazard Switch - Signal Hazard switch held down for > Refer to the electrical circuit
23 stuck low 10 seconds diagrams and check hazard switch
Hazard switch control circuit - control circuit for short circuit to
short circuit to power power. Repair wiring harness as
Jammed or faulty switch required. Clear DTC and retest
If no wiring faults are present,
check and install new hazard switch
as required. Clear DTC and retest

C111A- Right Stop Lamp - Right stop lamp control circuit Refer to the electrical circuit
11 Circuit short to ground - short circuit to ground diagrams and check right stop lamp
control circuit for short circuit to
ground. Repair wiring harness as
required. Clear DTC and retest

C111A- Right Stop Lamp - Right stop lamp control circuit Refer to the electrical circuit
15 Circuit short to battery - short circuit to power, open diagrams and check right stop lamp
or open circuit, high resistance control circuit for short circuit to
power, open circuit, high
resistance. Repair wiring harness as
required. Clear DTC and retest

C111B- Left Stop Lamp - Left stop lamp control circuit - Refer to the electrical circuit
11 Circuit short to ground short circuit to ground diagrams and check left stop lamp
control circuit for short circuit to
ground. Repair wiring harness as
required. Clear DTC and retest

C111B- Left Stop Lamp - Left stop lamp control circuit - Refer to the electrical circuit
15 Circuit short to battery short circuit to power, open diagrams and check left stop lamp
or open circuit, high resistance control circuit for short circuit to
power, open circuit, high
resistance. Repair wiring harness as
required. Clear DTC and retest

C1120- Reversing lamp - Reverse lamp control circuit - Refer to the electrical circuit
11 Circuit short to ground short circuit to ground diagrams and check reverse lamp
control circuit for short circuit to
ground. Repair wiring harness as
required. Clear DTC and retest

C1120- Reversing lamp - Reverse lamp control circuit - Refer to the electrical circuit
15 Circuit short to battery short circuit to power, open diagrams and check reverse lamp
or open circuit, high resistance control circuit for short circuit to
power, open circuit, high
resistance. Repair wiring harness as
required. Clear DTC and retest

P0460- Fuel Level Sensor A NOTE: Refer to the electrical circuit


11 Circuit - Circuit short to diagrams and check fuel level
ground This DTC will only be visible if both sender circuits A and B for short
fuel level sender circuits (A and B) circuit to ground. Repair wiring
are short circuit to ground harness as required. Clear DTC and
retest
Fuel gauge incorrectly shows If no wiring faults are present,
tank empty check and install new fuel gauge
Fuel level sender A analogue sender unit(s) as required. Clear
input circuit - short circuit to DTC and retest
ground
Fuel gauge sender unit fault

P0460- Fuel Level Sensor A NOTE: Refer to the electrical circuit


15 Circuit - Circuit short to diagrams and check fuel level
battery or open This DTC will only be visible if both sender circuits A and B for short
fuel level sender circuits (A and B) circuit to power, open circuit, high
are short circuit to power, open resistance. Repair wiring harness as
circuit, high resistance required. Clear DTC and retest
If no wiring faults are present,
Fuel gauge incorrectly shows check and install new fuel gauge
tank empty sender unit(s) as required. Clear
Fuel level sender A analogue DTC and retest
input circuit - short circuit to
power, open circuit, high
resistance
Fuel gauge sender unit fault

P0460- Fuel Level Sensor A NOTE: Refer to the electrical circuit


1C Circuit - Circuit voltage diagrams and check fuel level
out of range This DTC will only be visible if both sender circuits A and B for short
fuel level sender circuits (A and B) circuit to power, open circuit, high
are short circuit to power, open resistance. Repair wiring harness as
circuit, high resistance required. Clear DTC and retest
If no wiring faults are present,
Fuel gauge incorrectly shows check and install new fuel gauge
tank empty sender unit(s) as required. Clear
Fuel level sender A analogue DTC and retest
input circuit - short circuit to
power, open circuit, high
resistance
Fuel gauge sender unit fault

P04BB- Fuel Fill Door Lock Fuel flap lock/release NOTE:


11 Control Circuit/Open - mechanism inoperative
Circuit short to ground Fuel flap secure motor control Wiring checks should be made for short
circuit - short circuit to ground circuit to ground faults, NOT open circuit
Fuel flap locking motor fault faults

Refer to the electrical circuit


diagrams and check fuel flap secure
motor control circuit for short
circuit to ground. Repair wiring
harness as required. Clear DTC and
retest
If no wiring faults are present,
check and install new fuel flap
locking motor as required. Clear
DTC and retest
P04BB- Fuel Fill Door Lock Fuel flap lock/release NOTE:
12 Control Circuit/Open - mechanism inoperative
Circuit short to battery Fuel flap secure motor control Wiring checks should be made for short
circuit - short circuit to power circuit to power faults, NOT open circuit
Fuel flap locking motor fault faults

Refer to the electrical circuit


diagrams and check fuel flap secure
motor control circuit for short
circuit to power. Repair wiring
harness as required. Clear DTC and
retest
If no wiring faults are present,
check and install new fuel flap
locking motor as required. Clear
DTC and retest

P04BB- Fuel Fill Door Lock Fuel flap lock/release Refer to the electrical circuit
13 Control Circuit/Open - mechanism inoperative diagrams and check fuel flap secure
Circuit open Fuel flap secure motor control motor control circuit for open
circuit - open circuit, high circuit, high resistance. Repair
resistance wiring harness as required. Clear
Fuel flap locking motor fault DTC and retest
If no wiring faults are present,
check and install new fuel flap
locking motor as required. Clear
DTC and retest

P04BF- Fuel Fill Door Unlock Fuel flap lock/release NOTE:


11 Control Circuit/Open - mechanism inoperative
Circuit short to ground Fuel flap release motor control Wiring checks should be made for short
circuit - short circuit to ground circuit to ground faults, NOT open circuit
Fuel flap locking motor fault faults

Refer to the electrical circuit


diagrams and check fuel flap
release motor control circuit for
short circuit to ground. Repair
wiring harness as required. Clear
DTC and retest
If no wiring faults are present,
check and install new fuel flap
locking motor as required. Clear
DTC and retest

P04BF- Fuel Fill Door Unlock Fuel flap lock/release NOTE:


12 Control Circuit/Open - mechanism inoperative
Circuit short to battery Fuel flap release motor control Wiring checks should be made for short
circuit - short circuit to power circuit to power faults, NOT open circuit
Fuel flap locking motor fault faults

Refer to the electrical circuit


diagrams and check fuel flap
release motor control circuit for
short circuit to power. Repair
wiring harness as required. Clear
DTC and retest
If no wiring faults are present,
check and install new fuel flap
locking motor as required. Clear
DTC and retest

P04BF- Fuel Fill Door Unlock Fuel flap lock/release Refer to the electrical circuit
13 Control Circuit/Open - mechanism inoperative diagrams and check fuel flap
Circuit open Fuel flap release motor control release motor control circuit for
circuit - open circuit, high open circuit, high resistance. Repair
resistance wiring harness as required. Clear
Fuel flap locking motor fault DTC and retest
If no wiring faults are present,
check and install new fuel flap
locking motor as required. Clear
DTC and retest

P0571- Brake Switch 'A' NOTE: Refer to the electrical circuit


13 Circuit - Circuit open diagrams and check brake switch
This DTC will only set following the 'A' control circuit for open circuit,
completion of an on demand test high resistance. Repair wiring
routine (routine 0202h) when circuit harness as required. Clear DTC and
is open retest

Brake switch 'A' control circuit


- open circuit, high resistance

P1230- Fuel Pump Low Speed Fuel pump driver module Refer to the electrical circuit
12 Malfunction (VLCM) - supply circuit - short circuit to diagrams and check the power and
Circuit short to battery power ground connections to the fuel
Fuel pump driver module fault pump driver module
Refer to the electrical circuit
diagrams and check fuel pump
driver module supply circuit for
short circuit to power. Repair
wiring harness as required. Clear
DTC and retest
If no wiring faults are present,
check and install new fuel pump
driver module as required. Refer to
the warranty policy and procedures
manual, or determine if any prior
approval programme is in
operation, prior to the installation
of a new module. Clear DTC and
retest

P1230- Fuel Pump Low Speed Fuel pump driver module Refer to the electrical circuit
93 Malfunction (VLCM) - supply circuit - short circuit to diagrams and check the power and
No operation power, open circuit, high ground connections to the fuel
resistance pump driver module
Fuel pump relay may be either Refer to the electrical circuit
stuck open or stuck closed diagrams and check fuel pump
Fuel pump driver module fault driver module supply circuit for
short circuit to power, open circuit,
high resistance. Repair wiring
harness as required. Clear DTC and
retest
If no wiring faults are present,
check and install new fuel pump
relay as required. Clear DTC and
retest
If fault persists, check and install
new fuel pump driver module as
required. Refer to the warranty
policy and procedures manual, or
determine if any prior approval
programme is in operation, prior to
the installation of a new module.
Clear DTC and retest

P1346- Fuel Level Sensor B NOTE: Refer to the electrical circuit


11 Circuit - Circuit short to diagrams and check fuel level
ground This DTC will only be visible if both sender circuits A and B for short
fuel level sender circuits (A and B) circuit to ground. Repair wiring
are short circuit to ground harness as required. Clear DTC and
retest
Fuel gauge incorrectly shows If no wiring faults are present,
tank empty check and install new fuel gauge
Fuel level sender B analogue sender unit(s) as required. Clear
input circuit - short circuit to DTC and retest
ground
Fuel gauge sender unit fault

P1346- Fuel Level Sensor B NOTE: Refer to the electrical circuit


15 Circuit - Circuit short to diagrams and check fuel level
battery or open This DTC will only be visible if both sender circuits A and B for short
fuel level sender circuits (A and B) circuit to power, open circuit, high
are short circuit to power, open resistance. Repair wiring harness as
circuit, high resistance required. Clear DTC and retest
If no wiring faults are present,
Fuel gauge incorrectly shows check and install new fuel gauge
tank empty sender unit(s) as required. Clear
Fuel level sender B analogue DTC and retest
input circuit - short circuit to
power, open circuit, high
resistance
Fuel gauge sender unit fault

P1346- Fuel Level Sensor B NOTE: Refer to the electrical circuit


1C Circuit - Circuit voltage diagrams and check fuel level
out of range This DTC will only be visible if both sender circuits A and B for short
fuel level sender circuits (A and B) circuit to power, open circuit, high
are short circuit to power, open resistance. Repair wiring harness as
circuit, high resistance required. Clear DTC and retest
If no wiring faults are present,
Fuel gauge incorrectly shows check and install new fuel gauge
tank empty sender unit(s) as required. Clear
Fuel level sender B analogue DTC and retest
input circuit - short circuit to
power, open circuit, high
resistance
Fuel gauge sender unit fault
P1624- Anti-Theft System - NOTE: Check and install new right side 'A'
13 Circuit open pillar trim, as required
This DTC will only set following the Check correct central junction box
completion of an on demand test is installed and correctly connected
routine (routine 0202h) when circuit Refer to the electrical circuit
is open diagrams and check anti-theft
signal circuit from central junction
Vehicle alarm activated box for open circuit, high
following forced entry resistance. Repair wiring harness as
attempt/right side 'A' pillar required. Clear DTC and retest
trim removed/central junction
box disconnected
Central junction box replaced
incorrectly
Anti-theft signal circuit from
central junction box - open
circuit, high resistance

U0010- Medium Speed CAN Medium speed CAN failure - Refer to the electrical circuit
88 Communication Bus - Bus off diagrams and check the rear
Bus off junction box medium speed CAN
bus for short circuit to ground,
short circuit to power, open circuit,
high resistance, or short circuit
between the paired CAN wires

U0140- Lost Communication Loss of CAN communication Refer to the electrical circuit
00 With Body Control with central junction box diagrams and check the power and
Module - No sub type ground connections to the central
information junction box. Clear DTC and retest
Using the manufacturer approved
diagnostic system, complete a CAN
network integrity test. Refer to the
electrical circuit diagrams and
check the CAN network between
the central junction box and the
rear junction box
Check the central junction box for
related DTCs and refer to the
relevant DTC index

U0155- Lost Communication Loss of CAN communication Refer to the electrical circuit
00 With Instrument Panel with instrument cluster diagrams and check the power and
Cluster (IPC) Control ground connections to the
Module - No sub type instrument cluster. Clear DTC and
information retest
Using the manufacturer approved
diagnostic system, complete a CAN
network integrity test. Refer to the
electrical circuit diagrams and
check the CAN network between
the instrument cluster and the rear
junction box
Check the instrument cluster for
related DTCs and refer to the
relevant DTC index
U0159- Lost Communication Loss of CAN communication Refer to the electrical circuit
00 With Parking Assist with parking aid module diagrams and check the power and
Control Module "A" - ground connections to the parking
No sub type aid module. Clear DTC and retest
information Using the manufacturer approved
diagnostic system, complete a CAN
network integrity test. Refer to the
electrical circuit diagrams and
check the CAN network between
the parking aid module and the rear
junction box
Check the parking aid module for
related DTCs and refer to the
relevant DTC index

U0164- Lost Communication Loss of CAN communication Refer to the electrical circuit
00 With HVAC Control with climate control module diagrams and check the power and
Module - No sub type ground connections to the climate
information control module. Clear DTC and
retest
Using the manufacturer approved
diagnostic system, complete a CAN
network integrity test. Refer to the
electrical circuit diagrams and
check the CAN network between
the climate control module and the
rear junction box
Check the climate control module
for related DTCs and refer to the
relevant DTC index

U0214- Lost Communication Loss of CAN communication Refer to the electrical circuit
00 With Remote Function with keyless vehicle module diagrams and check the power and
Actuation - No sub type ground connections to the keyless
information vehicle module. Clear DTC and
retest
Using the manufacturer approved
diagnostic system, complete a CAN
network integrity test. Refer to the
electrical circuit diagrams and
check the CAN network between
the keyless vehicle module and the
rear junction box
Check the keyless vehicle module
for related DTCs and refer to the
relevant DTC index

U0242- Lost Communication Loss of CAN communication Refer to the electrical circuit
00 With Headlamp Control with headlamp control module diagrams and check the power and
Module 'B' - No sub 'B' ground connections to the
type information headlamp control module 'B'. Clear
DTC and retest
Using the manufacturer approved
diagnostic system, complete a CAN
network integrity test. Refer to the
electrical circuit diagrams and
check the CAN network between
the headlamp control module 'B'
and the rear junction box
Check the headlamp control
module 'B' for related DTCs and
refer to the relevant DTC index

U0257- Lost Communication Loss of CAN communication Refer to the electrical circuit
00 With Front with touch screen display diagrams and check the power and
Controls/Display module ground connections to the touch
Interface Module - No screen display module. Clear DTC
sub type information and retest
Using the manufacturer approved
diagnostic system, complete a CAN
network integrity test. Refer to the
electrical circuit diagrams and
check the CAN network between
the touch screen display module
and the rear junction box
Check the touch screen display
module for related DTCs and refer
to the relevant DTC index

U0264- Lost Communication Loss of CAN communication Refer to the electrical circuit
00 With Camera Module with rear view camera diagrams and check the power and
(Rear) - No sub type ground connections to the rear view
information camera. Clear DTC and retest
Using the manufacturer approved
diagnostic system, complete a CAN
network integrity test. Refer to the
electrical circuit diagrams and
check the CAN network between
the rear view camera and the rear
junction box
Check the rear view camera for
related DTCs and refer to the
relevant DTC index

U0300- Internal Control Control module software Re-configure the rear junction box
46 Module Software download corrupted using the manufacturer approved
Incompatibility - Rear junction box internal fault diagnostic system. Clear DTC and
Calibration/parameter - corrupt non-volatile memory retest
memory failure If fault persists, check and install a
new rear junction box. Refer to the
warranty policy and procedures
manual, or determine if any prior
approval programme is in
operation, prior to the installation
of a new module

U1000- Solid State Driver A fault condition has been NOTE:


00 Protection Active- detected on one (or more) of
Driver Disabled - No the rear junction box output The fault must be rectified on the relevant
sub type information circuits. To protect the control output circuit before the DTC is cleared.
module, the control module Repeated logs of this DTC will result in
internal output driver has been unrecoverable control module shut down
disabled. A further DTC will to prevent module damage
be logged indicating which
specific output has the fault Check rear junction box for
additional load related DTCs and
refer to remedial actions for those
DTCs. Clear DTC and retest

U1A14- CAN Initialisation Rear junction box internal fault Clear DTC and retest. Check and
49 Failure - Internal - CAN transceiver failure install a new rear junction box as
electronic failure required. Refer to the warranty
policy and procedures manual, or
determine if any prior approval
programme is in operation, prior to
the installation of a new module

U2101- Control Module Car configuration file incorrect Using the manufacturer approved
00 Configuration diagnostic system check and update
Incompatible - No sub the car configuration file as
type information required. Clear DTC and retest

U3000- Control Module - Rear junction box internal fault Clear DTC and retest. Check and
49 Internal electronic - electronic failure install a new rear junction box as
failure required. Refer to the warranty
policy and procedures manual, or
determine if any prior approval
programme is in operation, prior to
the installation of a new module
Published: 18-Apr-2014

2012.0 XF (X250), 100-00

General Information

Diagnostic Trouble Code Index - DTC: Remote


Keyless Entry Module (RFA) (G1426813)
DESCRIPTION AND OPERATION
Remote Keyless Entry Module (RFA)
CAUTIONS:

Diagnosis by substitution from a donor vehicle is NOT acceptable. Substitution of control modules does not
guarantee confirmation of a fault, and may also cause additional faults in the vehicle being tested and/or the
donor vehicle

When probing connectors to take measurements in the course of the pinpoint tests, use the adaptor kit, part
number 3548-1358-00

NOTES:

If the control module or a component is suspect and the vehicle remains under manufacturer warranty, refer to
the warranty policy and procedures manual (section B1.2), or determine if any prior approval programme is in
operation, prior to the installation of a new module/component

Generic scan tools may not read the codes listed, or may read only 5-digit codes. Match the 5 digits from the
scan tool to the first 5 digits of the 7-digit code listed to identify the fault (the last 2 digits give extra
information read by the manufacturer-approved diagnostic system)

When performing voltage or resistance tests, always use a digital multimeter accurate to three decimal places
and with a current calibration certificate. When testing resistance, always take the resistance of the digital
multimeter leads into account

Check and rectify basic faults before beginning diagnostic routines involving pinpoint tests

Inspect connectors for signs of water ingress, and pins for damage and/or corrosion

If diagnostic trouble codes are recorded and, after performing the pinpoint tests, a fault is not present, an
intermittent concern may be the cause. Always check for loose connections and corroded terminals

Where an 'on demand self-test' is referred to, this can be accessed via the 'diagnostic trouble code monitor' tab
on the manufacturers approved diagnostic system

The table below lists all diagnostic trouble codes (DTCs) that could be logged in the remote keyless entry module,
for additional diagnosis and testing information refer to the relevant diagnosis and testing section. For additional
information, refer to: Remote Keyless Entry Module (419-10 Multifunction Electronic Modules, Diagnosis and
Testing).

DTC Description Possible Causes Action


B102B- Passive Key - No Response Error - Using the manufacturer approved diagnostic system,
00 sub type general failure clear all passive keys, re-learn all passive keys
information
B10C1- Left Front Unlock No power supply Carry out any pinpoint tests associated with this DTC
00 Pull Switch - No to door handle using the manufacturer approved diagnostic system.
sub type Switch circuit Refer to the electrical circuit diagrams and check the
information open, or short power supply to the door handle. Check the switch
circuit to power circuit is not open circuit or short to power. Repair
wiring as required

B10C1- Left Front Unlock Signal stuck high - Carry out any pinpoint tests associated with this DTC
24 Pull Switch - button stuck in using the manufacturer approved diagnostic system.
Signal stuck high active position Check for stuck left front unlock switch. Refer to the
electrical circuit diagrams and check left front unlock
switch circuit for short to ground

B10C2- Left Rear Unlock No power supply Carry out any pinpoint tests associated with this DTC
00 Pull Switch - No to door handle using the manufacturer approved diagnostic system.
sub type Switch circuit Refer to the electrical circuit diagrams and check the
information open, or short power supply to the door handle. Check the switch
circuit to power circuit is not open circuit or short to power. Repair
wiring as required

B10C2- Left Rear Unlock Signal stuck high - Carry out any pinpoint tests associated with this DTC
24 Pull Switch - button stuck in using the manufacturer approved diagnostic system.
Signal stuck high active position Check for stuck left rear unlock switch. Refer to the
electrical circuit diagrams and check left rear unlock
switch circuit for short to ground

B10C3- Right Front No power supply Carry out any pinpoint tests associated with this DTC
00 Unlock Pull to door handle using the manufacturer approved diagnostic system.
Switch - No sub Switch circuit Refer to the electrical circuit diagrams and check the
type information open, or short power supply to the door handle. Check the switch
circuit to power circuit is not open circuit or short to power. Repair
wiring as required

B10C3- Right Front Signal stuck high - Carry out any pinpoint tests associated with this DTC
24 Unlock Pull button stuck in using the manufacturer approved diagnostic system.
Switch - Signal active position Check for stuck right front unlock switch. Refer to
stuck high the electrical circuit diagrams and check right front
unlock switch circuit for short to ground

B10C4- Right Rear No power supply Carry out any pinpoint tests associated with this DTC
00 Unlock Pull to door handle using the manufacturer approved diagnostic system.
Switch - No sub Switch circuit Refer to the electrical circuit diagrams and check the
type information open, or short power supply to the door handle. Check the switch
circuit to power circuit is not open circuit or short to power. Repair
wiring as required

B10C4- Right Rear Signal stuck high - Carry out any pinpoint tests associated with this DTC
24 Unlock Pull button stuck in using the manufacturer approved diagnostic system.
Switch - Signal active position Check for stuck right rear unlock switch. Refer to the
stuck high electrical circuit diagrams and check right front
unlock switch circuit for short to ground

B10C5- Trunk Unlock Signal stuck high - Carry out any pinpoint tests associated with this DTC
24 Pull Switch - button stuck in using the manufacturer approved diagnostic system.
Signal stuck high active position Check for stuck luggage compartment lid unlock
switch. Refer to the electrical circuit diagrams and
check luggage compartment lid unlock switch circuit
for short to ground

B10C6- Exterior Trunk Circuit intermittent Carry out any pinpoint tests associated with this DTC
1F Antenna - Circuit - general electrical using the manufacturer approved diagnostic system.
intermittent error Refer to the electrical circuit diagrams and check
exterior luggage compartment antenna circuits for
short to ground, power, open circuit

B10C7- Interior Trunk Circuit intermittent Carry out any pinpoint tests associated with this DTC
1F Antenna - Circuit - general electrical using the manufacturer approved diagnostic system.
intermittent error Refer to the electrical circuit diagrams and check
interior luggage compartment antenna circuits for
short to ground, power, open circuit

B10C8- Interior Center Circuit intermittent Carry out any pinpoint tests associated with this DTC
1F Antenna - Circuit - general electrical using the manufacturer approved diagnostic system.
intermittent error Refer to the electrical circuit diagrams and check
interior center antenna circuits for short to ground,
power, open circuit

B10C9- Interior Front Circuit intermittent Carry out any pinpoint tests associated with this DTC
1F Antenna - Circuit - general electrical using the manufacturer approved diagnostic system.
intermittent error Refer to the electrical circuit diagrams and check
interior front antenna circuits for short to ground,
power, open circuit

B10CA- Left Rear Door Circuit intermittent Carry out any pinpoint tests associated with this DTC
1F Handle Antenna - - general electrical using the manufacturer approved diagnostic system.
Circuit error Refer to the electrical circuit diagrams and check left
intermittent rear door handle antenna circuits for short to ground,
power, open circuit

B10CB- Right Rear Door Circuit intermittent Carry out any pinpoint tests associated with this DTC
1F Handle Antenna - - general electrical using the manufacturer approved diagnostic system.
Circuit error Refer to the electrical circuit diagrams and check
intermittent right rear door handle antenna circuits for short to
ground, power, open circuit

B10CC- Left Front Latch Signal stuck high - Check for stuck left front door latch clutch switch.
24 Clutch Switch - button stuck in Refer to the electrical circuit diagrams and check left
Signal stuck high active position front door latch clutch switch circuit for short to
ground

B10CD- Left Rear Latch Signal stuck high - Check for stuck left rear door latch clutch switch.
24 Clutch Switch - button stuck in Refer to the electrical circuit diagrams and check left
Signal stuck high active position front door latch clutch switch circuit for short to
ground

B10CE- Right Front Latch Signal stuck high - Check for stuck right front door latch clutch switch.
24 Clutch Switch - button stuck in Refer to the electrical circuit diagrams and check left
Signal stuck high active position front door latch clutch switch circuit for short to
ground

B10CF- Right Rear Latch Signal stuck high - Check for stuck right rear door latch clutch switch.
24 Clutch Switch - button stuck in Refer to the electrical circuit diagrams and check left
Signal stuck high active position front door latch clutch switch circuit for short to
ground

B10D1- Left Front Lock Signal stuck high - Check for stuck left front door handle lock switch.
24 Button - Signal button stuck in Refer to the electrical circuit diagrams and check left
stuck high active position front door latch clutch switch circuit for short to
ground

B10D2- Left Rear Lock Signal stuck high - Check for stuck left rear door handle lock switch.
24 Button - Signal button stuck in Refer to the electrical circuit diagrams and check left
stuck high active position front door latch clutch switch circuit for short to
ground

B10D3- Right Front Lock Signal stuck high - Check for stuck right front door handle lock switch.
24 Button - Signal button stuck in Refer to the electrical circuit diagrams and check left
stuck high active position front door latch clutch switch circuit for short to
ground

B10D4- Right Rear Lock Signal stuck high - Check for stuck right rear door handle lock switch.
24 Button - Signal button stuck in Refer to the electrical circuit diagrams and check left
stuck high active position front door latch clutch switch circuit for short to
ground

U0010- Medium Speed No subtype Carry out any pinpoint tests associated with this DTC
00 CAN information using the manufacturer approved diagnostic system.
Communication Carry out CAN network integrity test using the
Bus - No subtype manufacturer approved diagnostic system
information
U0140- Lost Missing message Carry out any pinpoint tests associated with this DTC
00 Communication from CJB using the manufacturer approved diagnostic system.
With Body Carry out CAN network integrity test using the
Control Module - manufacturer approved diagnostic system. Refer to
No subtype the electrical circuit diagrams and check power and
information ground supplies to CJB

U0142- Lost Missing message Carry out any pinpoint tests associated with this DTC
00 Communication from RJB using the manufacturer approved diagnostic system.
With Body Carry out CAN network integrity test using the
Control Module manufacturer approved diagnostic system. Refer to
"B" - No subtype the electrical circuit diagrams and check power and
information ground supplies to RJB

U0155- Lost Missing message Carry out any pinpoint tests associated with this DTC
00 Communication from instrument using the manufacturer approved diagnostic system.
With Instrument cluster Carry out CAN network integrity test using the
Panel Cluster manufacturer approved diagnostic system. Refer to
(IPC) Control the electrical circuit diagrams and check power and
Module - No ground supplies to instrument cluster
subtype
information
U0300- Internal Control Invalid Re-configure the RJB using the manufacturer
00 Module Software configuration approved diagnostic system. Clear the DTC and
Incompatibility - message is retest. If the DTC is still logged suspect the remote
No subtype received keyless entry module, refer to the new module
information installation note at the top of the DTC Index
U201F- External Receiver No subtype Suspect the RF receiver, check and install a new RF
00 - No subtype information - receiver as required, refer to the new
information communication module/component installation note at top of DTC
error Index

U201F- External Receiver Line open Refer to the electrical circuit diagrams and test RF
13 - Circuit open receiver communication circuit to remote keyless
entry module for short to ground or open circuit

U201F- External Receiver Transmission error Refer to the electrical circuit diagrams and check the
87 - Missing data line between the RF receiver and the remote
message keyless entry module for short, open circuit. Suspect
the RF receiver or remote keyless entry module,
check and install a new RF receiver or remote
keyless entry module as required, refer to the new
module/component installation note at top of DTC
Index

U2100- Initial No subtype Configure the Remote Keyless Entry module using
00 Configuration information the manufacturer approved diagnostic system
Not Complete -
No subtype
information
U2101- Control Module No subtype Re-configure the RJB using the manufacturer
00 Configuration information approved diagnostic system
Incompatible -
No subtype
information
U3000- Control Module - Internal electronic Install a new remote keyless entry module, refer to
49 Internal electronic failure the new module installation note at the top of the
failure DTC Index

U3002- Vehicle Vehicle/component Install correct/new module to vehicle specification,


81 Identification mis-match. Module refer to the new module/component installation note
Number - Invalid previously installed at the top of the DTC Index
serial data to other vehicle
received
U3003- Battery Voltage - Mis-match in Carry out any pinpoint tests associated with this DTC
62 Signal compare battery voltage, of using the manufacturer approved diagnostic system
failure 2 volts or more, Refer to the relevant section of the workshop manual
between remote and test the battery and charging system
keyless entry
module and RJB
Published: 01-Nov-2017

2012.0 XF (X250), 100-00

General Information

Diagnostic Trouble Code Index - DTC: Restraints


Control Module (RCM) (G1556961)
DESCRIPTION AND OPERATION
Restraints Control Module (RCM)
WARNINGS:

TO AVOID ACCIDENTAL DEPLOYMENT AND POSSIBLE PERSONAL INJURY, THE BACKUP


POWER SUPPLY MUST BE DEPLETED BEFORE REPAIRING OR REPLACING ANY AIR BAG
SUPPLEMENTAL RESTRAINT SYSTEM (SRS) COMPONENTS. TO DEPLETE THE BACKUP POWER
SUPPLY ENERGY, DISCONNECT THE BATTERY GROUND CABLE AND WAIT ONE MINUTE.
FAILURE TO FOLLOW THIS INSTRUCTION MAY RESULT IN PERSONAL INJURY.

Do not use a multimeter to probe the restraints control module. It is possible for the power from the meter
battery to trigger the activation of the airbags. Failure to follow this instruction may result in personal injury.

CAUTION:

Diagnosis by substitution from a donor vehicle is NOT acceptable. Substitution of control modules does not
guarantee confirmation of a fault, and may also cause additional faults in the vehicle being tested and/or the donor
vehicle.

NOTES:

It is advisable not to use a cellular phone or to have a cellular phone in close proximity when working on the
restraints control module or associated systems.

Given the legal implications of a restraints system failure, harness repairs to Air Bag module circuits are not
acceptable. Where the text refers to "REPAIR the circuit", this will normally mean the replacement of a
harness.

If the control module or a component is suspect and the vehicle remains under manufacturer warranty, refer to
the warranty policy and procedures manual, or determine if any prior approval programme is in operation,
prior to the installation of a new module/component.

Generic scan tools may not read the codes listed, or may read only 5-digit codes. Match the 5 digits from the
scan tool to the first 5 digits of the 7-digit code listed to identify the fault (the last 2 digits give extra
information read by the manufacturer-approved diagnostic system).

When performing voltage or resistance tests, always use a digital multimeter that has the resolution ability to
view 3 decimal places. For example, on the 2 volts range can measure 1mV or 2 K Ohm range can measure 1
Ohm. When testing resistance always take the resistance of the digital multimeter leads into account.

Check and rectify basic faults before beginning diagnostic routines involving pinpoint tests.

Inspect connectors for signs of water ingress, and pins for damage and/or corrosion.

If DTCs are recorded and, after performing the pinpoint tests, a fault is not present, an intermittent concern
may be the cause. Always check for loose connections and corroded terminals.
Check DDW for open campaigns. Refer to the corresponding bulletins and SSMs which may be valid for the
specific customer complaint and carry out the recommendations as required.

The table below lists all Diagnostic Trouble Codes (DTCs) that could be logged in the Restraints Control Module
(RCM). For additional diagnosis and testing information, refer to the relevant Diagnosis and Testing section in the
workshop manual. For additional information, refer to: Airbag and Safety Belt Pretensioner Supplemental Restraint
System (501-20B Supplementary Restraint System, Diagnosis and Testing) / Pedestrian Protection System (501-20C
Pedestrian Protection System, Diagnosis and Testing).

DTC Description Possible Causes Action


B0001- Driver Frontal Stage Driver airbag Refer to the electrical circuit diagrams and check the
11 1 Deployment (stage 1) circuit driver airbag (stage 1) circuit for short circuit to
Control - Circuit short circuit to ground. Check for intermittent short circuit within
short to ground ground the clockspring by rotating the steering column
during the checks. Install a new wiring harness as
necessary. Install a new clockspring as necessary. If
no wiring harness fault exists, using the
manufacturer approved diagnostic system, clear the
DTCs and retest

B0001- Driver Frontal Stage Driver airbag Refer to the electrical circuit diagrams and check the
12 1 Deployment (stage 1) circuit driver airbag (stage 1) circuit for short circuit to
Control - Circuit short to power power. Check for intermittent short circuit within the
short to battery clockspring by rotating the steering column during
the checks. Install a new wiring harness as
necessary. Install a new clockspring as necessary. If
no wiring harness fault exists, using the
manufacturer approved diagnostic system, clear the
DTCs and retest. If the fault persists, install a new
driver airbag

B0001- Driver Frontal Stage Driver airbag Refer to the electrical circuit diagrams and check the
13 1 Deployment (stage 1) circuit driver airbag (stage 1) circuit for open circuit, high
Control - Circuit open circuit, resistance. Check for intermittent short circuit within
open high resistance the clockspring by rotating the steering column
during the checks. Install a new wiring harness as
necessary. Install a new clockspring as necessary. If
no wiring harness fault exists, using the
manufacturer approved diagnostic system, clear the
DTCs and retest

B0001- Driver Frontal Stage Driver airbag Refer to the electrical circuit diagrams and check the
1A 1 Deployment (stage 1) circuit driver airbag (stage 1) circuit for short circuit
Control - Circuit short circuit between power and ground. Check for intermittent
resistance below between power short circuit within the clockspring by rotating the
threshold and ground steering column during the checks. Install a new
wiring harness as necessary. Install a new
clockspring as necessary. If no wiring harness fault
exists, using the manufacturer approved diagnostic
system, clear the DTCs and retest

B0001- Driver Frontal Stage Driver airbag Refer to the electrical circuit diagrams and check the
2B 1 Deployment (stage 1) circuit driver airbag (stage 1) circuit for short circuit to
Control - Signal cross short circuit to another restraints circuit. Check for intermittent
coupled another short circuit within the clockspring by rotating the
restraints circuit steering column during the checks. Install a new
wiring harness as necessary. Install a new
clockspring as necessary. If no wiring harness fault
exists, using the manufacturer approved diagnostic
system, clear the DTCs and retest. If the fault
persists, install a new driver airbag

B0001- Driver Frontal Stage Restraints Using the manufacturer approved diagnostic system,
56 1 Deployment control module re-configure the restraints control module with the
Control - is not latest level software
Invalid/incomplete configured
configuration correctly

B0002- Driver Frontal Stage Driver airbag Refer to the electrical circuit diagrams and check the
11 2 Deployment (stage 2) circuit driver airbag (stage 2) circuit for short circuit to
Control - Circuit short circuit to ground. Check for intermittent short circuit within
short to ground ground the clockspring by rotating the steering column
during the checks. Install a new wiring harness as
necessary. Install a new clockspring as necessary. If
no wiring harness fault exists, using the
manufacturer approved diagnostic system, clear the
DTCs and retest

B0002- Driver Frontal Stage Driver airbag Refer to the electrical circuit diagrams and check the
12 2 Deployment (stage 2) circuit driver airbag (stage 2) circuit for short circuit to
Control - Circuit short to power power. Check for intermittent short circuit within the
short to battery clockspring by rotating the steering column during
the checks. Install a new wiring harness as
necessary. Install a new clockspring as necessary. If
no wiring harness fault exists, using the
manufacturer approved diagnostic system, clear the
DTCs and retest. If the fault persists, install a new
driver airbag

B0002- Driver Frontal Stage Driver airbag Refer to the electrical circuit diagrams and check the
13 2 Deployment (stage 2) circuit driver airbag (stage 2) circuit for open circuit, high
Control - Circuit open circuit, resistance. Check for intermittent short circuit within
open high resistance the clockspring by rotating the steering column
during the checks. Install a new wiring harness as
necessary. Install a new clockspring as necessary. If
no wiring harness fault exists, using the
manufacturer approved diagnostic system, clear the
DTCs and retest

B0002- Driver Frontal Stage Driver airbag Refer to the electrical circuit diagrams and check the
1A 2 Deployment (stage 2) circuit driver airbag (stage 2) circuit for short circuit
Control - Circuit short circuit between power and ground. Check for intermittent
resistance below between power short circuit within the clockspring by rotating the
threshold and ground steering column during the checks. Install a new
wiring harness as necessary. Install a new
clockspring as necessary. If no wiring harness fault
exists, using the manufacturer approved diagnostic
system, clear the DTCs and retest

B0002- Driver Frontal Stage Driver airbag Refer to the electrical circuit diagrams and check the
2B 2 Deployment (stage 2) circuit driver airbag (stage 2) circuit for short circuit to
Control - Signal cross short circuit to another restraints circuit. Check for intermittent
coupled another short circuit within the clockspring by rotating the
restraints circuit steering column during the checks. Install a new
wiring harness as necessary. Install a new
clockspring as necessary. If no wiring harness fault
exists, using the manufacturer approved diagnostic
system, clear the DTCs and retest. If the fault
persists, install a new driver airbag

B0002- Driver Frontal Stage Restraints Using the manufacturer approved diagnostic system,
56 2 Deployment control module re-configure the restraints control module with the
Control - is not latest level software
Invalid/incomplete configured
configuration correctly

B0010- Passenger Frontal Passenger airbag Refer to the electrical circuit diagrams and check the
11 Stage 1 Deployment (stage 1) circuit passenger airbag (stage 1) circuit for short circuit to
Control - Circuit short to ground ground. Install a new wiring harness as necessary. If
short to ground no wiring harness fault exists, using the
manufacturer approved diagnostic system, clear the
DTCs and retest. If the fault persists, install a new
passenger airbag

B0010- Passenger Frontal Passenger airbag Refer to the electrical circuit diagrams and check the
12 Stage 1 Deployment (stage 1) circuit passenger airbag (stage 1) circuit for short circuit to
Control - Circuit short to power power. Install a new wiring harness as necessary. If
short to battery no wiring harness fault exists, using the
manufacturer approved diagnostic system, clear the
DTCs and retest. If the fault persists, install a new
passenger airbag

B0010- Passenger Frontal Passenger airbag Refer to the electrical circuit diagrams and check the
13 Stage 1 Deployment (stage 1) circuit passenger airbag (stage 1) circuit for open circuit,
Control - Circuit open circuit, high resistance. Install a new wiring harness as
open high resistance necessary. If no wiring harness fault exists, using the
manufacturer approved diagnostic system, clear the
DTCs and retest

B0010- Passenger Frontal Passenger airbag Refer to the electrical circuit diagrams and check the
1A Stage 1 Deployment (stage 1) circuit passenger airbag (stage 1) circuit for short circuit
Control - Circuit short circuit between power and ground. Install a new wiring
resistance below between power harness as necessary. If no wiring harness fault
threshold and ground exists, using the manufacturer approved diagnostic
system, clear the DTCs and retest

B0010- Passenger Frontal Passenger airbag Refer to the electrical circuit diagrams and check the
2B Stage 1 Deployment (stage 1) circuit passenger airbag (stage 1) circuit for short circuit to
Control - Signal cross short circuit to another restraints circuit. Install a new wiring
coupled another harness as necessary. If no wiring harness fault
restraints circuit exists, using the manufacturer approved diagnostic
system, clear the DTCs and retest. If the fault
persists, install a new passenger airbag

B0010- Passenger Frontal Restraints Using the manufacturer approved diagnostic system,
56 Stage 1 Deployment control module re-configure the restraints control module with the
Control - is not latest level software
Invalid/incomplete configured
configuration correctly

B0011- Passenger Frontal Passenger airbag Refer to the electrical circuit diagrams and check the
11 Stage 2 Deployment (stage 2) circuit passenger airbag (stage 2) circuit for short circuit to
Control - Circuit short to ground ground. Install a new wiring harness as necessary. If
short to ground no wiring harness fault exists, using the
manufacturer approved diagnostic system, clear the
DTCs and retest. If the fault persists, install a new
passenger airbag

B0011- Passenger Frontal Passenger airbag Refer to the electrical circuit diagrams and check the
12 Stage 2 Deployment (stage 2) circuit passenger airbag (stage 2) circuit for short circuit to
Control - Circuit short to power power. Install a new wiring harness as necessary. If
short to battery no wiring harness fault exists, using the
manufacturer approved diagnostic system, clear the
DTCs and retest. If the fault persists, install a new
passenger airbag

B0011- Passenger Frontal Passenger airbag Refer to the electrical circuit diagrams and check the
13 Stage 2 Deployment (stage 2) circuit passenger airbag (stage 2) circuit for open circuit,
Control - Circuit open circuit, high resistance. Install a new wiring harness as
open high resistance necessary. If no wiring harness fault exists, using the
manufacturer approved diagnostic system, clear the
DTCs and retest

B0011- Passenger Frontal Passenger airbag Refer to the electrical circuit diagrams and check the
1A Stage 2 Deployment (stage 2) circuit passenger airbag (stage 2) circuit for short circuit
Control - Circuit short circuit between power and ground. Install a new wiring
resistance below between power harness as necessary. If no wiring harness fault
threshold and ground exists, using the manufacturer approved diagnostic
system, clear the DTCs and retest

B0011- Passenger Frontal Passenger airbag Refer to the electrical circuit diagrams and check the
2B Stage 2 Deployment (stage 2) circuit passenger airbag (stage 2) circuit for short circuit to
Control - Signal cross short circuit to another restraints circuit. Install a new wiring
coupled another harness as necessary. If no wiring harness fault
restraints circuit exists, using the manufacturer approved diagnostic
system, clear the DTCs and retest. If the fault
persists, install a new passenger airbag

B0011- Passenger Frontal Restraints Using the manufacturer approved diagnostic system,
56 Stage 2 Deployment control module re-configure the restraints control module with the
Control - is not latest level software
Invalid/incomplete configured
configuration correctly

B0020- Left Side Air Bag Left side airbag Refer to the electrical circuit diagrams and check the
11 Deployment Control (seat) circuit left side airbag (seat) circuit for short circuit to
- Circuit short to short circuit to ground. Install a new wiring harness as necessary. If
ground ground no wiring harness fault exists, using the
manufacturer approved diagnostic system, clear the
DTCs and retest. If the fault persists, install a new
left side airbag (seat)

B0020- Left Side Air Bag Left side airbag Refer to the electrical circuit diagrams and check the
12 Deployment Control (seat) circuit left side airbag (seat) circuit for short circuit to
- Circuit short to short circuit to power. Install a new wiring harness as necessary. If
battery power no wiring harness fault exists, using the
manufacturer approved diagnostic system, clear the
DTCs and retest. If the fault persists, install a new
left side airbag (seat)

B0020- Left Side Air Bag Left side airbag Refer to the electrical circuit diagrams and check the
13 Deployment Control (seat) circuit left side airbag (seat) circuit for open circuit, high
- Circuit open open circuit, resistance. Install a new wiring harness as necessary.
high resistance If no wiring harness fault exists, using the
manufacturer approved diagnostic system, clear the
DTCs and retest

B0020- Left Side Air Bag Left side airbag Refer to the electrical circuit diagrams and check the
1A Deployment Control (seat) circuit left side airbag (seat) circuit for short circuit
- Circuit resistance short circuit between power and ground. Install a new wiring
below threshold between power harness as necessary. If no wiring harness fault
and ground exists, using the manufacturer approved diagnostic
system, clear the DTCs and retest

B0020- Left Side Air Bag Left side airbag Refer to the electrical circuit diagrams and check the
2B Deployment Control (seat) circuit left side airbag (seat) circuit for short circuit to
- Signal cross short circuit to another restraints circuit. Install a new wiring
coupled another harness as necessary. If no wiring harness fault
restraints circuit exists, using the manufacturer approved diagnostic
system, clear the DTCs and retest. If the fault
persists, install a new left side airbag (seat)

B0020- Left Side Air Bag Restraints Using the manufacturer approved diagnostic system,
56 Deployment Control control module re-configure the restraints control module with the
- Invalid/incomplete is not latest level software
configuration configured
correctly

B0021- Left Curtain Left side air Refer to the electrical circuit diagrams and check the
11 Deployment Control curtain circuit left side air curtain circuit for short circuit to ground.
1 - Circuit short to short circuit to Install a new wiring harness as necessary. If no
ground ground wiring harness fault exists, using the manufacturer
approved diagnostic system, clear the DTCs and
retest. If the fault persists, install a new left side air
curtain

B0021- Left Curtain Left side air Refer to the electrical circuit diagrams and check the
12 Deployment Control curtain circuit left side air curtain circuit for short circuit to power.
1 - Circuit short to short circuit to Install a new wiring harness as necessary. If no
battery power wiring harness fault exists, using the manufacturer
approved diagnostic system, clear the DTCs and
retest. If the fault persists, install a new left side air
curtain

B0021- Left Curtain Left side air Refer to the electrical circuit diagrams and check the
13 Deployment Control curtain circuit left side air curtain circuit for open circuit, high
1 - Circuit open open circuit, resistance. Install a new wiring harness as necessary.
high resistance If no wiring harness fault exists, using the
manufacturer approved diagnostic system, clear the
DTCs and retest

B0021- Left Curtain Left side air Refer to the electrical circuit diagrams and check the
1A Deployment Control curtain circuit left side air curtain circuit for short circuit between
1 - Circuit resistance short circuit power and ground. Install a new wiring harness as
below threshold between power necessary. If no wiring harness fault exists, using the
and ground manufacturer approved diagnostic system, clear the
DTCs and retest

B0021- Left Curtain Left side air Refer to the electrical circuit diagrams and check the
2B Deployment Control curtain circuit left side air curtain circuit for short circuit to another
1 - Signal cross short circuit to restraints circuit. Install a new wiring harness as
coupled another necessary. If no wiring harness fault exists, using the
restraints circuit manufacturer approved diagnostic system, clear the
DTCs and retest. If the fault persists, install a new
left side air curtain

B0021- Left Curtain Restraints Using the manufacturer approved diagnostic system,
56 Deployment Control control module re-configure the restraints control module with the
1- is not latest level software
Invalid/incomplete configured
configuration correctly

B0028- Right Side Air Bag Right side Refer to the electrical circuit diagrams and check the
11 Deployment Control airbag (seat) right side airbag (seat) circuit for short circuit to
- Circuit short to circuit short ground. Install a new wiring harness as necessary. If
ground circuit to ground no wiring harness fault exists, using the
manufacturer approved diagnostic system, clear the
DTCs and retest. If the fault persists, install a new
right side airbag (seat)

B0028- Right Side Air Bag Right side Refer to the electrical circuit diagrams and check the
12 Deployment Control airbag (seat) right side airbag (seat) circuit for short circuit to
- Circuit short to circuit short power. Install a new wiring harness as necessary. If
battery circuit to power no wiring harness fault exists, using the
manufacturer approved diagnostic system, clear the
DTCs and retest. If the fault persists, install a new
right side airbag (seat)

B0028- Right Side Air Bag Right side Refer to the electrical circuit diagrams and check the
13 Deployment Control airbag (seat) right side airbag (seat) circuit for open circuit, high
- Circuit open circuit open resistance. Install a new wiring harness as necessary.
circuit, high If no wiring harness fault exists, using the
resistance manufacturer approved diagnostic system, clear the
DTCs and retest

B0028- Right Side Air Bag Right side Refer to the electrical circuit diagrams and check the
1A Deployment Control airbag (seat) right side airbag (seat) circuit for short circuit
- Circuit resistance circuit short between power and ground. Install a new wiring
below threshold circuit between harness as necessary. If no wiring harness fault
power and exists, using the manufacturer approved diagnostic
ground system, clear the DTCs and retest

B0028- Right Side Air Bag Right side Refer to the electrical circuit diagrams and check the
2B Deployment Control airbag (seat) right side airbag (seat) circuit for short circuit to
- Signal cross circuit short another restraints circuit. Install a new wiring
coupled circuit to harness as necessary. If no wiring harness fault
another exists, using the manufacturer approved diagnostic
restraints circuit system, clear the DTCs and retest. If the fault
persists, install a new right side airbag (seat)

B0028- Right Side Air Bag Restraints Using the manufacturer approved diagnostic system,
56 Deployment Control control module re-configure the restraints control module with the
- Invalid/incomplete is not latest level software
configuration configured
correctly

B0029- Right Curtain Right side air Refer to the electrical circuit diagrams and check the
11 Deployment Control curtain circuit right side air curtain circuit for short circuit to
1 - Circuit short to short circuit to ground. Install a new wiring harness as necessary. If
ground ground no wiring harness fault exists, using the
manufacturer approved diagnostic system, clear the
DTCs and retest. If the fault persists, install a new
right side air curtain

B0029- Right Curtain Right side air Refer to the electrical circuit diagrams and check the
12 Deployment Control curtain circuit right side air curtain circuit for short circuit to
1 - Circuit short to short circuit to power. Install a new wiring harness as necessary. If
battery power no wiring harness fault exists, using the
manufacturer approved diagnostic system, clear the
DTCs and retest. If the fault persists, install a new
right side air curtain

B0029- Right Curtain Right side air Refer to the electrical circuit diagrams and check the
13 Deployment Control curtain circuit right side air curtain circuit for open circuit, high
1 - Circuit open open circuit, resistance. Install a new wiring harness as necessary.
high resistance If no wiring harness fault exists, using the
manufacturer approved diagnostic system, clear the
DTCs and retest

B0029- Right Curtain Right side air Refer to the electrical circuit diagrams and check the
1A Deployment Control curtain circuit right side air curtain circuit for short circuit between
1 - Circuit resistance short circuit power and ground. Install a new wiring harness as
below threshold between power necessary. If no wiring harness fault exists, using the
and ground manufacturer approved diagnostic system, clear the
DTCs and retest. If the fault persists, install a new
right side air curtain

B0029- Right Curtain Right side air Refer to the electrical circuit diagrams and check the
2B Deployment Control curtain circuit right side air curtain circuit for short circuit to
1 - Signal cross short circuit to another restraints circuit. Install a new wiring
coupled another harness as necessary. If no wiring harness fault
restraints circuit exists, using the manufacturer approved diagnostic
system, clear the DTCs and retest. If the fault
persists, install a new right side air curtain

B0029- Right Curtain Restraints Using the manufacturer approved diagnostic system,
56 Deployment Control control module re-configure the restraints control module with the
1- is not latest level software
Invalid/incomplete configured
configuration correctly
B0050- Driver Seatbelt Driver buckle Refer to the electrical circuit diagrams and check the
11 Sensor - Circuit short switch circuit driver buckle switch circuit for short circuit to
to ground short circuit to ground
ground

B0050- Driver Seatbelt Driver buckle Refer to the electrical circuit diagrams and check the
12 Sensor - Circuit short switch circuit driver buckle switch circuit for short circuit to power
to battery short circuit to
power

B0050- Driver Seatbelt Driver buckle Refer to the electrical circuit diagrams and check the
13 Sensor - Circuit open switch circuit driver buckle switch circuit for open circuit, high
open circuit, resistance
high resistance

B0050- Driver Seatbelt Driver buckle Refer to the electrical circuit diagrams and check the
1D Sensor - Circuit switch circuit driver buckle switch circuit for short circuit to
current out of range short circuit to ground, short circuit to power, open circuit, high
ground, short resistance
circuit to power,
open circuit,
high resistance

B0050- Driver Seatbelt Driver buckle Refer to the electrical circuit diagrams and check the
2B Sensor - Signal cross switch circuit driver buckle switch circuit for short circuit to
coupled short circuit to another restraints circuit
another
restraints circuit

B0050- Driver Seatbelt Restraints Using the manufacturer approved diagnostic system,
56 Sensor - control module re-configure the restraints control module with the
Invalid/incomplete is not latest level software
configuration configured
correctly

B0052- Passenger Seatbelt Passenger Refer to the electrical circuit diagrams and check the
11 Sensor - Circuit short buckle switch passenger buckle switch circuit for short circuit to
to ground circuit short ground
circuit to ground

B0052- Passenger Seatbelt Passenger Refer to the electrical circuit diagrams and check the
12 Sensor - Circuit short buckle switch passenger buckle switch circuit for short circuit to
to battery circuit short power
circuit to power

B0052- Passenger Seatbelt Passenger Refer to the electrical circuit diagrams and check the
13 Sensor - Circuit open buckle switch passenger buckle switch circuit for open circuit, high
circuit open resistance
circuit, high
resistance

B0052- Passenger Seatbelt Passenger Refer to the electrical circuit diagrams and check the
1D Sensor - Circuit buckle switch passenger buckle switch circuit for short circuit to
current out of range circuit short ground, short circuit to power, open circuit, high
circuit to resistance
ground, short
circuit to power,
open circuit,
high resistance

B0052- Passenger Seatbelt Passenger Refer to the electrical circuit diagrams and check the
2B Sensor - Signal cross buckle switch passenger buckle switch circuit for short circuit to
coupled circuit short another restraints circuit
circuit to
another
restraints circuit

B0052- Passenger Seatbelt Restraints Using the manufacturer approved diagnostic system,
56 Sensor - control module re-configure the restraints control module with the
Invalid/incomplete is not latest level software
configuration configured
correctly

B0090- Left Frontal Front left impact Refer to the electrical circuit diagrams and check the
11 Restraints Sensor - sensor circuit front left impact sensor circuit for short circuit to
Circuit short to short circuit to ground
ground ground

B0090- Left Frontal Front left impact Refer to the electrical circuit diagrams and check the
15 Restraints Sensor - sensor circuit front left impact sensor circuit for short circuit to
Circuit short to short circuit to power, open circuit, high resistance
battery or open power, open
circuit, high
resistance

B0090- Left Frontal Restraints Using the manufacturer approved diagnostic system,
56 Restraints Sensor - control module re-configure the restraints control module with the
Invalid/incomplete is not latest level software
configuration configured
correctly

B0090- Left Frontal Front left impact Check the front left impact sensor circuit for correct
81 Restraints Sensor - sensor circuit routing. Check for vehicle modifications or non-
Invalid serial data electrical genuine accessories
received interference Using the manufacturer approved diagnostic system,
Front left impact clear the DTCs and retest. If the fault persists, install
sensor internal a new front left impact sensor
failure

B0090- Left Frontal Front left impact Using the manufacturer approved diagnostic system,
96 Restraints Sensor - sensor internal clear the DTCs and retest. If the fault persists, install
Component internal failure a new front left impact sensor
failure
B0092- Left Side Restraints Left C pillar Refer to the electrical circuit diagrams and check the
11 Sensor 2 - Circuit impact sensor left C pillar impact sensor circuit for short circuit to
short to ground circuit short ground
circuit to ground

B0092- Left Side Restraints Left C pillar Refer to the electrical circuit diagrams and check the
15 Sensor 2 - Circuit impact sensor left C pillar impact sensor circuit for short circuit to
short to battery or circuit short power, open circuit, high resistance
open circuit to power,
open circuit,
high resistance

B0092- Left Side Restraints Restraints Using the manufacturer approved diagnostic system,
56 Sensor 2 - control module re-configure the restraints control module with the
Invalid/incomplete is not latest level software
configuration configured
correctly

B0092- Left Side Restraints Left C pillar Check the left C pillar impact sensor circuit for
81 Sensor 2 - Invalid impact sensor correct routing. Check for vehicle modifications or
serial data received circuit electrical non-genuine accessories
interference Using the manufacturer approved diagnostic system,
Left C pillar clear the DTCs and retest. If the fault persists, install
impact sensor a new left C pillar impact sensor
internal failure

B0092- Left Side Restraints Left C pillar Using the manufacturer approved diagnostic system,
96 Sensor 2 - impact sensor clear the DTCs and retest. If the fault persists, install
Component internal internal failure a new left C pillar impact sensor
failure
B0095- Right Frontal Front right Refer to the electrical circuit diagrams and check the
11 Restraints Sensor - impact sensor front right impact sensor circuit for short circuit to
Circuit short to circuit short ground
ground circuit to ground

B0095- Right Frontal Front right Refer to the electrical circuit diagrams and check the
15 Restraints Sensor - impact sensor front right impact sensor circuit for short circuit to
Circuit short to circuit short power, open circuit, high resistance
battery or open circuit to power,
open circuit,
high resistance

B0095- Right Frontal Restraints Using the manufacturer approved diagnostic system,
56 Restraints Sensor - control module re-configure the restraints control module with the
Invalid/incomplete is not latest level software
configuration configured
correctly

B0095- Right Frontal Front right Check the front right impact sensor circuit for
81 Restraints Sensor - impact sensor correct routing. Check for vehicle modifications or
Invalid serial data circuit electrical non-genuine accessories
received interference Using the manufacturer approved diagnostic system,
Front right clear the DTCs and retest. If the fault persists, install
impact sensor a new front right impact sensor
internal failure

B0095- Right Frontal Front right Using the manufacturer approved diagnostic system,
96 Restraints Sensor - impact sensor clear the DTCs and retest. If the fault persists, install
Component internal internal failure a new front right impact sensor
failure
B0097- Right Side Restraints Right C pillar Refer to the electrical circuit diagrams and check the
11 Sensor 2 - Circuit impact sensor right C pillar impact sensor circuit for short circuit to
short to ground circuit short ground
circuit to ground

B0097- Right Side Restraints Right C pillar Refer to the electrical circuit diagrams and check the
15 Sensor 2 - Circuit impact sensor right C pillar impact sensor circuit for short circuit to
short to battery or circuit short power, open circuit, high resistance
open circuit to power,
open circuit,
high resistance

B0097- Right Side Restraints Restraints Using the manufacturer approved diagnostic system,
56 Sensor 2 - control module re-configure the restraints control module with the
Invalid/incomplete is not latest level software
configuration configured
correctly

B0097- Right Side Restraints Right C pillar Check the right C pillar impact sensor circuit for
81 Sensor 2 - Invalid impact sensor correct routing. Check for vehicle modifications or
serial data received circuit electrical non-genuine accessories
interference Using the manufacturer approved diagnostic system,
Right C pillar clear the DTCs and retest. If the fault persists, install
impact sensor a new right C pillar impact sensor
internal failure

B0097- Right Side Restraints Right C pillar Using the manufacturer approved diagnostic system,
96 Sensor 2 - impact sensor clear the DTCs and retest. If the fault persists, install
Component internal internal failure a new right C pillar impact sensor
failure
B00B5- Driver Seat Track Driver seat track Refer to the electrical circuit diagrams and check the
11 Position Restraints position sensor driver seat track position sensor circuit for short
Sensor - Circuit short circuit short circuit to ground
to ground circuit to ground

B00B5- Driver Seat Track Driver seat track Refer to the electrical circuit diagrams and check the
12 Position Restraints position sensor driver seat track position sensor circuit for short
Sensor - Circuit short circuit short circuit to power
to battery circuit to power

B00B5- Driver Seat Track Driver seat track Refer to the electrical circuit diagrams and check the
13 Position Restraints position sensor driver seat track position sensor circuit for open
Sensor - Circuit open circuit open circuit, high resistance
circuit, high
resistance

B00B5- Driver Seat Track Driver seat track Refer to the electrical circuit diagrams and check the
1D Position Restraints position sensor driver seat track position sensor circuit for short
Sensor - Circuit circuit short circuit to ground, short circuit to power, open circuit,
current out of range circuit to high resistance
ground, short
circuit to power,
open circuit,
high resistance

B00B5- Driver Seat Track Driver seat track Refer to the electrical circuit diagrams and check the
2B Position Restraints position sensor driver seat track position sensor circuit for short
Sensor - Signal cross circuit short circuit to another position sensor circuit
coupled circuit to
another position
sensor circuit

B00B5- Driver Seat Track Restraints Using the manufacturer approved diagnostic system,
56 Position Restraints control module re-configure the restraints control module with the
Sensor - is not latest level software
Invalid/incomplete configured
configuration correctly

B00C5- Passenger Seat Track Passenger seat Refer to the electrical circuit diagrams and check the
11 Position Restraints track position passenger seat track position sensor circuit for short
Sensor - Circuit short sensor circuit circuit to ground
to ground short circuit to
ground

B00C5- Passenger Seat Track Passenger seat Refer to the electrical circuit diagrams and check the
12 Position Restraints track position passenger seat track position sensor circuit for short
Sensor - Circuit short sensor circuit circuit to power
to battery short circuit to
power

B00C5- Passenger Seat Track Passenger seat Refer to the electrical circuit diagrams and check the
13 Position Restraints track position passenger seat track position sensor circuit for open
Sensor - Circuit open sensor circuit circuit, high resistance
open circuit,
high resistance

B00C5- Passenger Seat Track Passenger seat Refer to the electrical circuit diagrams and check the
1D Position Restraints track position passenger seat track position sensor circuit for short
Sensor - Circuit sensor circuit circuit to ground, short circuit to power, open circuit,
current out of range short circuit to high resistance
ground, short
circuit to power,
open circuit,
high resistance

B00C5- Passenger Seat Track Passenger seat Refer to the electrical circuit diagrams and check the
2B Position Restraints track position passenger seat track position sensor circuit for short
Sensor - Signal cross sensor circuit circuit to another position sensor circuit
coupled short circuit to
another position
sensor circuit

B00C5- Passenger Seat Track Restraints Using the manufacturer approved diagnostic system,
56 Position Restraints control module re-configure the restraints control module with the
Sensor - is not latest level software
Invalid/incomplete configured
configuration correctly

B00D2- Restraint System Restraints Using the manufacturer approved diagnostic system,
01 Malfunction Indicator warning check the instrument cluster for related DTCs and
1 - General electrical indicator fault refer to the relevant DTC index
failure reported by the
instrument

You might also like