0% found this document useful (0 votes)
303 views1 page

Sag Rod

Download as pdf or txt
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 1

Design Of Sag Rod

Load Calculations
Dead Load due to Sheet 0.063 Kn/sq m
Additional Dead Load 0.060 Kn/sq m

Dead load due to purlin weight,


10% of purlin weigh extra for cleat 0.045 Kn/sq m
Total dead load 0.168 Kn/sq m
Live Load 0.547 Kn/sq m
Wind load -1.07 Kn/sq m
The dead load component normal to
roof 0.236 Kn/m
The live load component normal to
roof 0.77028 Kn/m
The total load normal to roof 2.487 Kn/m

Sag rod will be designed as


2.5% load of axial capacity of
purlin or bending compressive
stress of purlin
Induced force in sag rod 0.12503 Kn
Induced reaction in sag rod 0.13318 Kn
(consider 250
Mpa yield
Area Reuired for sag rod 0.88789 sq mm Stress)
Area Provided 113.04 sq mm

Provide 12 mm dia sag rod.

Bolt Design
(Considering
4.6 grade of
Ultimate Capacity of Bolt 400 N/ sqmm Bolt)
Yield Capacity of Bolt 240 N/ sqmm
Diameter of Bolt 12 mm
gross area of Bolt 113.04 Sq mm
Shank area of Bolt 88.736 Sq mm
Tension capacity of bolt, Tnb 31945.1 N
Or
30829.1 N
Tension capacity of bolt, Tnb 30829.1 N (Min of Both)
Design Tension Capacity of Bolt 24.7 Kn OK