4 digits display.
Easy to use with front panel keypad.
5A or 60 mV , CT20/30 current transformer or 60 mV input feature (Please Specify at Order).
Programmable scale range between 5A and 9999A.
Multifunctional alarm output (NO+NC) for upper and lower limits.
Communication feature over isolated RS485, using ModBus RTU protocol (Optional). OUT AC DC ACDC A
Measuring type can be selected as AC, DC or true RMS.
Keylock feature.
0-20mA, 4-20mA, 0-10V or 1-5V output selection (Specified devices with output type 'A' only).
CE marked according to European Norms.
CT20/30 should be ordered separately if required.
SET
EA54
Order Code : EA54
1 2 3 4
1- Supply Voltage 2 - Input 3 -Output 4 - Isolated Modbus
UV......... 90-250V AC CT........................... CT20/30 R......... 08A Relay RSI........ RS485 Modbus Available
Current Transformer input OR 60mV. A........... Analog ( Specify at order)
LV......... 10-30V DC / X1........................... 1A
8-24V AC Default (Blank)...... 5A or 60mV. 10 11 12 13 14 15 16 17 18
TECHNICAL SPECIFICATIONS
ENVIRONMENTAL CONDITIONS
Ambient/Storage Temperature 0 ... +50°C/-25 ... 70°C
Max. Relative Humidity 80% Relative humidity for temperatures up to 31°C, decreasing linearly to 50% at 40°C.
Rated Pollution Degree According to EN 60529 Front panel : IP65 , Rear panel : IP20
Height Max. 2000m
KEEP AWAY device from exposed to corrosive, volatile and flammable gases or liquids and DO NOT USE the device in similar hazardous locations.
ELECTRICAL CHARACTERISTICS
OUTPUTS
Analog Output 0-20mA DC, 4-20mA DC, 0-10V DC or 1-5V DC can be selected on program. ( Load resistance for current outputs Max. 500Ω ).
Output Relay : 250V AC, 8A (for resistive load), NO+NC
Life Expectancy For Relay Mechanical 30.000.000; Electrical 100.000 operation. 250V AC, 8A (resistive load).
HOUSING
Housing Type Suitable for EN60715 Standards, TH35 rail type.
Dimensions W54xH94xD68mm
Weight Approx. 250g (after packing)
Enclosure Material Self extinguishing plastics.
TM
EN
1/5 EA54-EN-04-220103
1 2 3 4 5 6 7 8 9
If these keys are pressed and held for 3 seconds, “Programming Mode” is entered or it returns to “Running Mode”. If and keys SET UPLL LOLL
&
are pressed respectively while parameter names are displayed, than it returns to measured value. +0.00
SET
SET
SET
Out1 REVISION NUMBER
ConF
SET Day.Month Year Measured Value
This menu available for specified devices with & &
i " R " ( R E L AY ) i n o r d e r c o d e o n l y. SET
01.01 2015 0.00
& &
Please check "Output Type" in the order code.
& If these keys are pressed and held together, revision
&
Current Conversion Ratio Out1 Output date appears as day, month and year.
While revision information displayed and if one of the pressed
It can be adjusted between 5(/5) and 9999(/5). If this parameter OtYp It can be adjusted as n.o. or N.c. If n.o is selected, incase of key is released, measured value is displayed again.
changes, upper limit value is set to maximum scale, minimum limit alarm, out relay is activated.
value is set to minimum scale and hysteresis values are set to 0.1
SETTING UP THE PARAMETERS
Measuring Method Upper Limit Value SET SET
ACdC
tYpE It can be adjusted to ac , dc or acdc. LEDs on the top of the UPLL It can be adjusted between minimum and maximum scale that tYPE dC
display indicates the adjusted measurement method. is specified with c.tr.r parameter. SET
This parameter can’t be lower than (l0ll - HY5U - HY5U ) If key is pressed, the current value of the parameter appears by flashing on the display.
Decimal Indicator By using “UP” or “DOWN” navigation keys, selected parameter can be adjusted to
d.pnt If measured value is lower than 10, it will be displayed as Hysteresis Value for Upper Limit the desired value.
(0.000) , (0.00) , (0.0) or (0) or (0). HY5U It can be adjusted between 0 and ctrr /5 parameter. This SET
After the setting up the parameters, if set key is pressed again, adjusted
If measured value between 10 and 100, it will be displayed as parameter can’t be higher than ( Upll - l0ll - HY5L ). When parameter name appears on display.
(0.00) ,(0.0) or (0). ctrr changed, HY5U gets the value of 0.1 .
If measured value between 100 and 1000, it will be displayed
DEFAULT SETTINGS
as (0.0) or (0).
Delay Time for Upper Limit Alarm
dPnt type may change according to relay parameters value. Powered on device by pressing key. dPAr message appears
dLYU It can be adjusted between 0 and 900 .
Samping Time on display and device resets to default settings.
Optn If 1 ( 1 ) is selected ; sampling time of the measurement is 250ms,
If 2 ( 2 ) is selected, it is 500ms. ERROR MESSAGES
If 3 ( 3 ) is selected, it is 750ms. Lower Limit Value
If 4 ( 4 ) is selected, it is 1 second. LOLL It can be adjusted between lower scale and upper scale that is Measured current value is higher than maximum scale.
specified with c.tr.r parameter.
Device Address This parameter can’t be higher than (UPLL - HY5U -
Adr5 It can be adjusted between 1 - 247 . HY5L) value. Measured current value is lower than minimum scale.
2/5 EA54-TR-02-180509
DIMENSIONS & CONNECTION DIAGRAM
Input
46m For mounting the device on rail :
m
Push the device to rail in direction 1 and UP.l1 + HYS.U
make sure that rail-lock is interlocked to rail. UP.l1
UP.l1 - HYS.U
68mm
m
m
direction 2 and pull the device in direction 3.
4
6
5
,
LO.l1
Push the rail-lock with a flat tip screwdriver in
LO.l1 - HYS.L
t
dly.U dly.U dly.l dly.l
Out
A.out = n.o.
3 t
Equipment is protected throughout by Out
2 DOUBLE INSULATION
94m m
m 5
4
m
A.out = n.c.
1 t
Holding screw 0.4-0.5Nm.
Rail-lock
(rms)
ac dc Ac.dc
EN EA54 ammeters are rail mounted control devices. Device must be used to according to instructions. Mounting and electrical A
connections must be carried on by a qualified staff and must be according to the relevant locally applicable regulations. During an 1 1
installation, all of the cables that are connected to the device must be free of electrical power. The device must be protected 0 A 0.000 A
T/2 T 3T/2 2T
against inadmissible humidity, vibrations and severe soiling. Make sure that the operation temperature is not exceeded. The cables 2 2
should not be close to the power cables or components. -A
CAUTION :
1
A2
A
If 5A / CT20-30 and 60mV inputs are connected at the same time, the measurement will be incorrect. 0.308 A A
0
p
EN INDUSTRIAL ELECTRONICS EN INDUSTRIAL ELECTRONICS EN INDUSTRIAL ELECTRONICS T/2 T 3T/2 2T
2
EA54-LV-A-RSI EA54-UV-R EA54-UV-CT-R-RSI
A1 A1
A
AC/DC AMMETER AC/DC AMMETER AC/DC AMMETER CT20
Measurement Input
0.386 A
0
8 680407 723256 8 680407 719631 8 680407 723270 0-300A T/2 T 3T/2 p2
10-30V DC/8-24V AC 90-250V AC 90-250V AC
50/60Hz 4,5VA
1
1
50/60Hz 5VA
1
50/60Hz 5VA
A
CTt2
Max. Max.
0
1
10 11 12 13 14
2
60mV 5A 60mV 5A 60mV 20/30
11
3
0
A 0.000 A
2000
AC/DC AC/DC + +
3
+ T/2 T 3T/2 2T
2
1
+ + +
4
4
OUTPUT OUTPUT -A
13
250V AC 8A 250V AC 8A
RESISTIVE RESISTIVE
4
1
COM COM
7
LOAD
7
LOAD
A
15 16
B B
A 1 A 1 A 1
ANLG OUT
CAT II
8
CAT II
GND CAT II A Made in Turkey A
9
Made in Turkey
9
Made in Turkey
SN: XXXXXXXXX
SN: XXXXXXXXX SN: XXXXXXXXX 0 T/2 T 3T/2 2T 2 2 2
NOTE : Fuse
A
F 100mA
SUPPLY: 250V AC Switch A d d2 A d A d
90-250V AC
veya 10 Line UV/LV Please see page 5 for Modbus Connection Diagram 0 d d T T 2 T T
10-30V DC /
8-24V AC T 2T
50/60Hz 7VA 11 Neutral Supply
1) Mains supply cords shall meet the requirements of IEC 60227
or IEC 60245. A
A 1 A 1
2) In accordance with the safety regulations, the power supply
switch shall bring the identification of the relevant instrurment 0 0.000
and it should be easily accessible by the operator. T/2 T 3T/2 2T
3 3
Fuse should be connected. Cable size: 1,5mm² -A
3/5 EA54-TR-02-180509
EN EA54 DIGITAL AMMETER MODBUS PROTOCOL ADDRESS MAP
HOLDING REGISTERS FOR OUTPUT TYPE UNIT “R” (RELAY) DEVICES
Holding Register
Data Read/Write Default
Adresleri Data Content Parameter
Decimal Hex Type Name Permission Value
0000d 0x0000 word Alarm output status 0tyP R/W no
0001d 0x0001 word Current replacement rate ctrr R/W 5
0002d 0x0002 word The upper limit of the setpoint UPLL R/W 5.00
0003d 0x0003 word The upper limit of the hysteresis value HY5U R/W 0.10
0004d 0x0004 word Delay time for the upper limit alarm dlyU R/W 0
0005d 0x0005 word The lower limit of the setpoint L0Ll R/W 0.00
0006d 0x0006 word The lower limit of the hysteresis value HY5L R/W 0.10
0007d 0x0007 word Delay time for the lower limit alarm dLyl R/W 0
0008d 0x0008 word Measurement method (0=AC, 1=DC, 2=ACDC) typE R/W aCdC
0009d 0x0009 word Decimal point. ( 0 = 0 , 1 = 0.0 , 2 = 0.00 , 3 = 0.000 ) dpnt R/W 0.00
Sampling time of the measurement value. If 1 is selected, it is
0010d 0x000A word 250ms. If 2 is selected, it is 500ms. If 3 is selected, it is 750ms. 0PTN R/W 4
If 4 is selected, it is 1 second.
Device address for RS485 network connection.
0011d 0x000B word Adjustable between 1-247. aDr5 R/W 1
Baudrate (0=Off;1=1200;2=2400; 3=4800; 4=9600; 5=19200
0012d 0x000C word 6= 38400; 7= 57600; 8= 115200) BAUD R/W oFF
0013d 0x000D word Delay Time for Initial Upper Limit Alarm 5dly R/W 0
*0014d 0x000E word Input Type (0 = Ct20 , 1= Ct30 , 2 = 5Hnt ) ityp R/W Ct20
*0015d 0x000F word Number of windings for transformer turn R/W 1
* 14d and 15d addresses are available for only in CT20/30 input type devices.
HOLDING REGISTERS FOR OUTPUT TYPE UNIT “BLANK” (NO RELAY) OR “A” (ANALOG) DEVICES
*0006d 0x0006 word Input Type ( 0 = Ct20 , 1 = Ct30 , 2 = 5Hnt ) ityp R/W Ct20
* 6d and 7d addresses are available for only in CT20/30 input type devices.
** Address 8d is available for only in “A” (Analog) input type devices.
NOTE :
In devices with input type CT20/30, following parameter settings will change automatically if the ityp parameter is changed.
If ityp = Ct20 ; UpLL = 300.0 , LoLL = 0 , Hy5U = 0.10 , Hy5L = 0.10
If ityp = Ct30 ; UpLL = 120.0 , LoLL = 0 , Hy5U = 0.10 , Hy5L = 0.10
TM
EN
4/5 EA54-EN-04-220103
EN EA54-xx-x-xxx-RSI INPUT REGISTERS DEVICES
Input Register Read / Write
Addresses Data Parameter Permission
Decimal Hex Type Data Content Name
00d 0x00 Bit Relay output state (0=OFF; 1=ON) -- Read Only
COILS FOR OUTPUT TYPE UNIT “R” (RELAY) DEVICES
Coil Addresses Data Parameter Read/Write
Data Content Default
Decimal Hex Type Name Permission Value
Note 1 : Coil and Discrete input parameters are not available in the devices those have no relay
Note 3 : Value read in 0th address of input register gives the measured value. Also, the 1st address of the input register specifies
the decimal part of the measured current value.
For example ;
Value read in 0th address of input register is 2842, if value read in 1st address from input register as 1, it is 284.2
Value read in 0th address of input register is 2842, if value read in 1st address from input register as 2, it is 28.42
Value read in 0th address of input register is 2842, if value read in 1st address from input register as 3, it is 2.842
B A B A B A can be controlled. B A
+ - + - - -
+
+
Termination should be accomplished by
attaching 120 Ohm resistors to the start
and at the end of the communication line.
* Applies to devices with Modbus function.
TM
EN
5/5 EA54-EN-04-220103