Export Locks File Project Wise Data For Working Remotely
Export Locks File Project Wise Data For Working Remotely
Opening MicroStation (.dgn) files from ProjectWise puts a load on your network connection as the parent
(.dgn) and all of its references are copied out to your pw_work folders. If you work with (.dgn) files that
have reference attachments, you may find that it improves your experience when using MicroStation or
Local_MicroStation to not log into ProjectWise, but instead, to [Cancel] out and open (.dgn) files that reside
on your computer. The steps below will explain a good method of exporting your project (.dgn) documents,
so that you may work on them locally. You should “export – locks file” any (.dgn) that you will edit locally,
including reference attachments if you will also be editing them. It is a good practice to import documents
when you are finished editing them, or at the end of each day.
1. Create a folder for your exported documents on the C: drive
Open File Explorer; navigate to C:\Share, C:\USR, or C:\Work and create a new folder with a name like
Export_K99876.
In the picture above, File Explorer is open to C:\USR showing a folder named Export_K99876.
2. Export the master (.dgn) from ProjectWise using “Export – locks file” to lock the document in
ProjectWise
Open ProjectWise Explorer; navigate to your project folder that contains the (.dgn) documents. Right-click
on the parent (.dgn) – recognized by the MicroStation icon with the white directory tree “glyph” in the lower
right corner. Select “Export” from the right-click menu.
In the picture above, the ProjectWise Explorer is open to the K99876 project in the User Training folders
with the folders expanded on the left side. The active folder is 2_Plan_Sheets. R_K99876_pl_01.dgn is
selected and highlighted blue. Its blue MicroStation icon shows the white tree glyph indicating that it has
reference attachments. The right-click menu is open and the "Export" command is highlighted blue.
Choose “Export – Locks file, changes can be re-imported” and click [Next>].
The Document Export Wizard is shown above with “Export – Locks file, changes can be re-imported”
selected.
Use [Browse…] and navigate into This PC > OSDisk (C:) and select the folder that you previously created in
C:\USR, and click [OK], then [Next>].
The picture above shows the Document Export Wizard with the Export folder: field and [Browse...] button
on the left. The Browse For Folder dialog is shown at the right with Export_K99876 highlighted gray.
Click the [Finish] button on the Document Export Wizard to dismiss the dialog.
The parent (.dgn) file has been exported and locked in ProjectWise, and all of the reference files have been
simply exported (Send to Folder – without locking) and they are all in the same folder on the C: drive.
The picture above shows ProjectWise Explorer on the left with the parent file showing the “Exported” status
icon which looks like a diskette. On the right is File Explorer showing the parent file highlighted and all of
the reference files in the same folder. The references were exported from 3_Base_Files in ProjectWise and
are in the same folder with the parent so that MicroStation can find them when you open the parent (.dgn)
on the C: drive.
3. Export the Referenced (.dgn) files from ProjectWise using “Export – locks file” to lock the
documents in ProjectWise
In the ProjectWise Explorer; navigate into the 3_Base_Files folder, which is probably where your references
are stored. Make a selection set of all the (.dgn) base documents that you plan to edit locally – and select
“Export” from the right-click menu.
The Document Export Wizard should still be configured as shown in step #2 above with “Export – Locks file,
changes can be re-imported” selected. Accept the same export folder location, then click [Next >]. Click
[Yes to All] when the Warning! Dialog opens. You must overwite the files that were exported in step #2 in
order to lock the documents in ProjectWise. Choose [Yes to All], then [Finish].
4. Use Local_MicroStation shortcut to launch and open the exported parent (.dgn)
The picture above shows MicroStation open to the plan sheet (.dgn). The References dialog is open at the
right showing the reference hierarchy. The C_Sheets model that displays title block names is selected and
highlighted blue and you can see the permanent address in the "dms" folders. A right-click menu is displayed
and Exchange is highlighted orange. The next picture below shows the result of making an exchange.
5. Use “Exchange” to transfer between the Parent file and its Reference(s) in the “export” folder
When you use Exchange to open a reference file for editing, the file named in your title bar will be the file in
your “export” folder. The reference dialog reports the permanent address in the “dms” folders, but when
you use Exchange, the reference in the “export” folder will be opened.
The picture above shows MicroStation open to the C_Sheets model of the “name” file in the “export” folder.
A red rectangle in the upper left corner surrounds the path and name of the open (.dgn) file in the "export"
folder. A red arrow points to the Previous Model pick list. Using the Previous Model button is the quickest
way to transfer back into the plan sheet file.
6. Import edited files back into ProjectWise or use Update Server Copy to retain the lock
It is a good practice to push data from exported documents back up to ProjectWise when you are finished
editing them, or at the end of the day. Use “Import” if you are finished editing the file, and use “Update
Server Copy” if you will continue editing the file locally and wish to keep it locked.
Open ProjectWise Explorer; navigate to your project folder that contains the locked (.dgn) documents.
Right-click on the locked document or a selection set of locked documents and choose either “Import” or
“Update Server Copy” from the right-click menu. Both commands leave the copies of the files on your
computer and push the changes up to ProjectWise; “Import” goes one step further and unlocks the
document in ProjectWise so that someone else may edit it.
When the documents reside in one folder in ProjectWise, you may make a selection set of locked documents
and choose “Update Server Copy” or “Import” off the right-click menu, as shown in the picture below.
The picture above shows a selection set of the locked base files in the ProjectWise Explorer. The right-click
menu shows the highlighted command "Import". Importing will update the documents in ProjectWise with
the edits that were performed locally and unlock the documents. The choice to “Update Server Copy” can
be seen four lines below the highlighted “Import” command.