0% found this document useful (0 votes)
59 views3 pages

Battery Nikend

This document provides specifications for the SBLE 40 cell including: - It has a capacity of 40 Ah and uses a polypropylene container. - Dimensions are 260 mm in height, 123 mm width, and blocks of 4 cells are 239 mm long. - It can provide up to 115 amps for 1 second at 1V per cell and up to 102 watts for 5 seconds at 1V per cell. - Performance data is provided on current discharge rates and power discharge rates at different voltages over various time periods.

Uploaded by

caohuynhtai
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
59 views3 pages

Battery Nikend

This document provides specifications for the SBLE 40 cell including: - It has a capacity of 40 Ah and uses a polypropylene container. - Dimensions are 260 mm in height, 123 mm width, and blocks of 4 cells are 239 mm long. - It can provide up to 115 amps for 1 second at 1V per cell and up to 102 watts for 5 seconds at 1V per cell. - Performance data is provided on current discharge rates and power discharge rates at different voltages over various time periods.

Uploaded by

caohuynhtai
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Friday, May 7, 2021

SBLE 40 - Cell data sheet


Classification
Wiring principle Normal
Brand Saft
Cell type SBLE 40
Cell P/N 310545874
Capacity at 5 hours rate 40 Ah
IEC Designation KL40P
According to IEC 60623

Physical data

Overall height 260 mm


Cell height
Width 123 mm Weight per cell 3.0 Kg
Length - Block length - 2 cells -
Block length - 3 cells - Block length - 4 cells 239 mm
Block length - 5 cells 298 mm Block length - 6 cells 356 mm
Block length - 7 cells - Block length - 8 cells -
Block length - 9 cells - Block length - 10 cells -
Construction

Container material Polypropylene No. of terminals/polarity 1


Separator type Grid Terminal material Steel
Connection torque 11.0 +/- 1.1 Nm Vent type flame arresting vent
Terminal size M6 SW 10 mm (small)
Handle No

Plates

Positive Negative
Type of plates Pocket Type of plates Pocket

Electrolyte

Electrolyte type: Renewal E13 Max/Min 35 mm


Electrolyte type: Initial E22 Vent oil quantity
Electrolyte per cell: Liquid 0.9 liters

Connection

Cable area of internal 16 mm² End-lug (and external cable) 10 mm²


connection cables

SAFT confidential and proprietary. The data herein given are for information purposes only and are not binding on SAFT. They may be modified
without prior notice. Please contact a SAFT representative in order to obtain confirmation of the above data.
Visit our website at www.saftbatteries.com
(376961) Version: 3.00, Last updated on 04/2021 P 1/3
Friday, May 7, 2021

SBLE 40 - Cell data sheet


Charging

Float voltage 1.42 V/Cell High rate voltage (min) 1.47 V/Cell
Single-level voltage 1.43 V/Cell

Resistance/Short circuit

Internal resistance 3.13 mOhm Short circuit current 495 A

Performance data

Current discharge

After prolonged float charge of fully charged cells. Available amperes at +20°C +/- 5°C (+68°F +/- 9°F)

V/Cell 10h 8h 5h 3h 2h 1.5h 1h 30m 20m 15m 10m 5m 1m 30s 5s 1s

1 4.10 5.10 8.00 12.8 17.2 21.3 28.3 37.8 42.8 46.4 49.9 63.1 71.4 79.3 102 115

1.05 4.08 5.05 7.84 12.4 15.4 18.3 24.0 32.2 37.6 40.5 44.8 45.5 57.6 64.7 84.4 95.0

1.1 4.00 4.90 7.53 10.7 13.6 16.2 19.2 25.7 28.6 30.5 34.0 40.2 46.5 53.4 69.8 79.3

1.14 3.92 4.61 6.62 9.40 11.7 13.1 15.8 20.2 22.8 24.5 25.8 29.4 38.0 44.0 57.7 66.1

1.16 3.68 4.21 5.73 8.06 10.0 10.9 12.9 17.0 19.9 22.3 22.8 26.9 34.7 40.1 52.6 60.3

Power discharge

Available power (W), after prolonged float charged of fully charged cells at +20°C +/- 5°C (+68°F +/- 9°F)

V/Cell 10h 8h 5h 3h 2h 1.5h 1h 30m 20m 15m 10m 5m 1m 30s 5s 1s

1 4.75 5.83 8.94 13.7 18.0 22.0 28.9 38.2 43.0 46.6 50.0 63.1 71.4 79.3 102 115

1.05 4.75 5.82 8.91 13.6 16.7 19.7 25.5 34.0 39.6 42.6 47.1 47.8 60.5 68.0 88.6 100

1.1 4.68 5.70 8.69 12.1 15.3 18.1 21.3 28.4 31.6 33.6 37.5 44.2 51.2 58.7 76.8 87.2

1.14 4.60 5.40 7.73 10.9 13.4 15.1 18.1 23.1 26.0 27.9 29.4 33.6 43.3 50.2 65.8 75.4

1.16 4.32 4.94 6.74 9.43 11.6 12.7 15.0 19.7 23.1 25.8 26.5 31.2 40.2 46.6 61.0 69.9

SAFT confidential and proprietary. The data herein given are for information purposes only and are not binding on SAFT. They may be modified
without prior notice. Please contact a SAFT representative in order to obtain confirmation of the above data.
Visit our website at www.saftbatteries.com
(376961) Version: 3.00, Last updated on 04/2021 P 2/3
Friday, May 7, 2021

SBLE 40 - Cell data sheet


Kt Factor

Current discharge

After prolonged float charge of fully charged cells. Kt factor at +20°C +/- 5°C (+68°F +/- 9°F)

V/Cell 10h 8h 5h 3h 2h 1.5h 1h 30m 20m 15m 10m 5m 1m 30s 5s 1s

1 9.8 7.84 5.00 3.12 2.33 1.88 1.42 1.06 0.93 0.86 0.80 0.63 0.56 0.50 0.39 0.35

1.05 9.8 7.92 5.10 3.23 2.59 2.18 1.67 1.24 1.06 0.99 0.89 0.88 0.69 0.62 0.47 0.42

1.1 10.0 8.16 5.31 3.74 2.94 2.46 2.09 1.55 1.40 1.31 1.17 1.00 0.86 0.75 0.57 0.50

1.14 10.2 8.68 6.04 4.26 3.43 3.05 2.54 1.98 1.76 1.63 1.55 1.36 1.05 0.91 0.69 0.61

1.16 10.9 9.5 6.98 4.96 4.02 3.66 3.09 2.35 2.01 1.80 1.75 1.49 1.15 1.00 0.76 0.66

Power discharge
Kt factor power, after prolonged float charged of fully charged cells at +20°C +/- 5°C (+68°F +/- 9°F)

V/Cell 10h 8h 5h 3h 2h 1.5h 1h 30m 20m 15m 10m 5m 1m 30s 5s 1s

1 8.42 6.87 4.47 2.92 2.22 1.81 1.39 1.05 0.93 0.86 0.80 0.63 0.56 0.50 0.39 0.35

1.05 8.42 6.87 4.49 2.93 2.39 2.03 1.57 1.18 1.01 0.94 0.85 0.84 0.66 0.59 0.45 0.40

1.1 8.55 7.02 4.60 3.30 2.62 2.21 1.88 1.41 1.27 1.19 1.07 0.90 0.78 0.68 0.52 0.46

1.14 8.70 7.41 5.17 3.68 2.98 2.66 2.21 1.73 1.54 1.43 1.36 1.19 0.92 0.80 0.61 0.53

1.16 9.25 8.09 5.94 4.24 3.44 3.14 2.66 2.03 1.73 1.55 1.51 1.28 0.99 0.86 0.66 0.57

SAFT confidential and proprietary. The data herein given are for information purposes only and are not binding on SAFT. They may be modified
without prior notice. Please contact a SAFT representative in order to obtain confirmation of the above data.
Visit our website at www.saftbatteries.com