Chauvin Arnoux Multimeters 2023 Catalogue

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

Simp l e m e a su r e m e n t a t t h e b e s t pr ic e

2023

Universal Test & Measurement


Electrical Safety Testers
Other Measurements
Laborator y Instruments
www.multimetrix.fr 1
C ontent s

◆ Universal Test & Measurement page 3


◆ Electrical Safety Testers page 8
◆ Other Measurements page 9
◆ Laboratory Instruments page 11

2
Univ er s al Te s t & Me a sur e me n t

Pocket multimeters
100 A to 600 A

◆ Auto-ranging

CM 604 CM 610 CM 625


Clamping diameter 30 mm Clamping diameter 30 mm
Display 4,000 counts, backlit Display 2,000 counts 4,300 counts
Measurement type AVG Measurement type TRMS AC/DC
Ranges 40 A / 400 A Ranges 40 A / 400 A
IAC Basic accuracy 2.5% of reading + 10 cts 5% to 100% of the range IDC Basic accuracy - 1.5 % + 5 cts
Best resolution 0.01 A Best resolution 0.01 A
Ranges 400 mV / 4 V / 40 V / 400 V / 600 V Ranges 200 A / 600 A 40 A / 400 A
VDC Basic accuracy 0.5% of reading + 5 cts IAC Basic accuracy 1.9 % + 5 cts 1.5 % + 5 cts
Best resolution 0.1 mV Best resolution 0.1 A 0.01 A
4 V / 40 V / 400 V / 600 V Ranges 200 mV / 2 V / 20 V / 200 V / 600 V 4 V / 40 V / 400 V / 600 V
Ranges
(50 Hz - 1 kHz) VDC Basic accuracy 0.7 % + 3 cts 0.75 % + 2 cts
VAC 1.2% of reading + 5 cts Best resolution 0.1 mV 1 mV
Basic accuracy
5% to 100% of the range
Ranges 2 V / 20 V / 200 V / 600 V 4 V / 40 V / 400 V / 600 V
Best resolution 0.001 V
VAC Basic accuracy 1.5 % + 5 cts 1 % + 5 cts
Ranges 400 Ω / 4 kΩ / 40 kΩ / 400 kΩ / 4 MΩ / 40 MΩ
Best resolution 1 mV
Resistance Basic accuracy 1.2%L + 5 cts
200 Ω / 2 kΩ / 20 kΩ / 200 kΩ / 2MΩ 400 Ω / 4 kΩ / 40 kΩ / 400 kΩ / 4MΩ
Best resolution 0.1 Ω Ranges
/ 20 MΩ / 40 MΩ
NCV (EF) Oui Resistance
Basic accuracy 1.5 % + 5 cts 0.9 % + 2 cts
Frequency (V) 4 Hz / 40 Hz / 400 Hz / 4 kHz / 10 kHz Best resolution 0,1 Ω
Continuity (with buzzer) Yes (< 50 Ω) Threshold 90 Ω 50 Ω
Diode test Yes Continuity
Protection 600 V rms
4 nF / 40 nF / 400 nF / 4 µF / 40 µF Diode test Yes -
Capacitance
400 µF / 4 mF
Automatic zero adjustment - Yes
Temperature - 18°C … + 1000°C (K thermocouple)
Other features MAX HOLD
Min/Max / Data Hold
Other features Automatic power-off (15 min.), deactivatable Dimensions / weigEX-VAT 189 x 71 x 37 mm / 200 g 189 x 71 x 37 mm / 220 g
Torch function (lighting of measurement point) Safety 300 V CAT III according to IEC 61010-1, IEC 61010-2-032
Dimensions / weight 75 x 35 x 225 mm / 295 Gr 1 carrying bag, 1 set of red/black test-probe leads
Accessories supplied
Safety 600V CAT III and 2 x 1.5 V LR3/AAA batteries
1 set of red/black test leads, 3 x 1.5 V AAA /
Accessories supplied
LR03 batteries, 1 K thermocouple and 1 bag

◆ CM 604 ◆ CM 610 ◆ CM 625


To order To order To order
P06232009Z P06232002 P06232003

www.multimetrix.fr 3
Univ er s al Te s t & Me a su r e me n t

Digital multimeters

CM 605
Clamping diameter 12.5 mm
Display 10,000 counts
Measurement type AVG
Ranges 10 A / 80 A / 100 A
IAC / IDC Basic accuracy 2 % (AC) 2.5 % (DC)
Best resolution 1 mA
Ranges 600 V rms
VAC /VDC Basic accuracy 1.5 % (AC) 1 % (DC)
Best resolution 0.1 V ◆ CM 605
Ranges 10 kΩ To order
Resistance Basic accuracy 1%
P06232007
Best resolution 1Ω
Threshold 50 Ω
Continuity
Protection 600 V rms
Automatic zero adjustment Yes
Analogue output: 10 mV/A AC or DC, 4.5 % + 0.5 mV, 20 kHz à ± 3 dB, Z = 3 kΩ
Other features
HOLD / PEAK (peak value)
Dimensions / weight 202 x 70 x 34 mm / 180 g
Safety 300 V Cat. III selon IEC 61010-1, IEC 61010-2-032
Accessories supplied 1 carrying bag, 1 set of red/black test-probe leads and 2 x 1.5 V LR3/AAA batteries

4
Digital multimeters

DMM 54 DMM 121 DMM 141


Display 4,000 counts, backlit 4,000 counts
Measurement type 3 measurements / s AVG TRMS AC/DC
Ranges 400 µA / 4000 µA / 40 mA / 400 mA / 4 A /10 A 400 µA / 4 000 µA / 40 mA / 400 mA / 4 A / 10 A (1)
IDC Basic accuracy 1% of reading + 5 cts 1% of reading + 3 cts
Best resolution 0.1 µA 0.1 µA
400 µA / 4000 µA / 40 mA / 400 mA / 4 A / 10 A
Ranges 400 µA / 4 000 µA / 40 mA / 400 mA / 4 A / 10 A (1)
(50 Hz - 400 Hz)
IAC
Basic accuracy 1% of reading + 5 cts from 5% to 100% of range 1% of reading + 5 cts
Best resolution 0.1 µA 0.1 µA
Ranges 400 mV / 4 V / 40 V / 400 V / 600 V 400 mV / 4 V / 40 V / 400 V / 600 V
VDC Basic accuracy 0.5% of reading + 8 cts 0.5% of reading + 3 cts
Best resolution 0.1 mV 0.1 mV
4 V / 40 V / 400 V / 600 V
Ranges 400 mV / 4 V / 40 V / 400 V / 600 V
(50 Hz - 1 kHz)
VAC
Basic accuracy 1.2% of reading + 3 cts from 5% to 100% of range 1% of reading + 5 cts
Best resolution 0.001 V 0.1 mV
Ranges 400 Ω / 4 kΩ / 40 kΩ / 400 kΩ / 4 MΩ / 40 MΩ 400 Ω / 4 kΩ / 4 0 kΩ / 4 00 kΩ / 4 MΩ / 4 0 MΩ
Resistance Basic accuracy 1.2% of reading + 5 cts 0.5% of reading + 2 cts
Best resolution 0.1 Ω 0.1 Ω
NCF (EF) Oui -
Electrical frequency (V) 4 Hz / 40 Hz / 400 Hz / 4 kHz / 10 kHz (V > 15V) -
Electronic frequency (V) 2,000 Hz .. 10 MHz -
Continuity (with buzzer) Yes (< 50 Ω) Yes
Diode test Yes Yes
Capacitance 4 nF / 40 nF / 400 nF / 4 µF / 40 µF / 400 µF / 4 mF 50 nF / 500 nF / 5 µF / 50 µF / 100 µF
Temperature - 18 °C … + 1000 °C (K thermocouple) 0 … 1832 °F -
Frequency 4 Hz / 40 Hz / 400 Hz / 4 kHz / 10 kHz (V > 15V) 5 Hz / 50 Hz / 500 Hz / 5 kHz / 50 kHz / 500 kHz / 5 MHz
Duty cycle - -
Range selection Automatic / Manual Automatic / Manual (2)
Min/Max / Data Hold / REL Automatic power-off Backlighting, Data HOLD,
Other features
(15 min.), deactivatable Deactivatable automatic power-off, Relative mode
Safety 600 V CAT III 600 V Cat. III according to IEC 61010-1, IEC 61010-2-033
Dimensions / Weight 154 x 74 x 43 mm / 210 g 181 x 92 x 57 mm / 335 g (without batteries)
1 set of Ø2 mm dual mode CAT II / CAT III-IV test probe leads,
Accessories supplied 1 Tc-K wire thermocouple, 1 Tc-K/Ø4 male safety banana adapter, 1 sheath, 1 set of red/black test-probe leads and 2 x 1.5 V AA batteries
2 x 1.5 V AAA batteries

(1)
20 A max / 30 s max - (2) except for frequency and capacitance

◆ DMM 54 ◆ DMM 121 ◆ DMM 141


To order To order To order
P06231424Z P06231421Z P06231422Z

www.multimetrix.fr 5
Univ er s al Te s t & Me a su r e me n t

Digital multimeters

DMM 210 DMM 220 DMM 230 DMM 240


Display 6,000 counts - Backlit with bargraph 40,000 counts - Backlit with bargraph
Measurement type AVG TRMS AC/DC TRMS AC/DC
Bandwidth 40 Hz to 1 kHz 50 Hz to 1 kHz
Ranges 600 µA / 6000 µA / 60 mA / 600 mA / 6 A / 10 A 400 µA / 4000 µA / 40 mA / 400 mA / 10 A (20 A max.)
Basic accuracy 1.0 % + 3 cts 1.0 % + 3 cts
IDC
Best resolution 0.1 µA 0.01 µA
4-20 mA - – 25 % to 125 %

Ranges 600 µA / 6000 µA / 60 mA / 600 mA / 6 A / 10 A (20 A max.) 400 µA / 4000 µA / 40 mA / 400 mA / 10 A (20 A max.)
IAC Basic accuracy 1.5 % + 3 cts 1.5 % + 3 cts
Best resolution 0.1 µA 0.1 µA
Ranges 600 mV / 6 V / 60 V / 600 V / 1000 V 400 mV / 4 V / 40 V / 400 V / 1000 V
VDC Basic accuracy 0.09 % + 2 cts 0.06 % + 2 cts
Best resolution 0.1 mV 0.01 mV
Ranges 6 V / 60 V / 600 V / 1000 V 400 mV / 4 V / 40 V / 400 V / 1000 V
VAC Basic accuracy 1.0 % + 3 cts 1.0 % + 3 cts
Best resolution 1 mV 0.1 mV
Ranges 600 Ω / 6 kΩ / 60 kΩ / 600 kΩ / 6 MΩ / 60 MΩ 400 Ω / 4 kΩ / 40 kΩ / 400 kΩ / 4 MΩ / 40 MΩ
Resistance Basic accuracy 0.3 % + 4 cts 0.3 % + 4 cts
Best resolution 0.1 Ω 0.01 Ω
Audible continuity Yes / 0.1 Ω Yes / 0.1 Ω
Diode test Yes Yes
Capacitance - 0.01 nF to 1000 µF 0.001 nF to 40 mF
Temperature (K thermocouple) - – 45 °C to +750 °C – 50 °C to +1000 °C
Electrical 10.00 to 400.00 Hz 40.00 to 400.00 Hz
Frequency
Electronic 0.001 Hz to 10.00 MHz 0.001 Hz to 100.00 MHz
Duty cycle 0.1 to 99.9 % 0.1 to 99.90 %
Range selection Autorange / Manual
Automatic shutdown (deactivatable),
Other features Automatic shutdown (deactivatable), DATA HOLD, Relative mode – MIN, MAX
DATA HOLD, Relative mode – MIN, MAX, PEAK (1 ms)
Ingress protection IP 67
Safety 600 V Cat. IV / 1000 V Cat. III selon IEC 61010-1, IEC 61010-2-033
Dimensions / Weight 187 x 81 x 50 mm / 342 g approx.

9V battery,
Accessories supplied 9V battery, 1 set of red/black test-probe leads + adapter for K thermocouple + type K temperature probe
1 set of red/black test-probe leads

◆ DMM 210 ◆ DMM 220


To order To order
P06231410 P06231411

◆ DMM 230 ◆ DMM 240


To order To order
P06231412 P06231413

6
Phase detector Socket and 10 mA / 30 mA
with built-in torch RCD tester

VT 12 VT 35
• No-contact phase detection • Quick testing of your power sockets
• Extra-bright white LED torch (wiring of the Earth, Phase and Neutral)
• Operating voltage: 200V to 600V AC 50/60 Hz • Quick testing of 30 mA RCD tripping
• IEC 61010 600V CAT III • Powered by the mains supply
• Powered by 2 x AAA/LR03 batteries • Safety: 250 V Cat. II (IEC 61010) - CE

Dimensions / Weight: 176 x 26 mm / 48 g Dimensions / Weight: 85 x 56 x 31 mm / 250 g

To order
P06230202

To order
Wallplug Tester P06230301

VT 11
◆ 2P+E mains socket
and RCD tester Voltage tester
• For renovation work and quick checking
of 2P+E socket connections VT 14
• Tests performed: • Voltage testing: 12 V to 690 V~ (7 diodes)
•PE (Earth (1)) not connected • Impedance: 400 k
• Line (L) not connected • Operating frequency: DC and 50/60 Hz
• Neutral (N) not connected • Polarity test with "+" and «-» diodes
• Inversion of Line (L) / Neutral (N) • Protection up to 1,000 V
• Inversion of Line (L) / Earth (PE) • IEC 61010 600 V CAT III
• Presence of voltage on PE(1) • Powered by 1 x 9 V 6LR61 battery
• RCD tripping up to up to 30 mA
(1) “Earth” or “Protective conductor”
Dimensions / Weight: 193 x 47 x 36 mm / 170 g

Dimensions / Weight: 78 x 72 x 79 mm / 70 g

To order To order
P06230304 P06230203

www.multimetrix.fr 7
E l e c tric al S af e t y Te s te r s

Digital earth resistance tester

ERT 201
◆ 2 P and 3 P measurement methods To order
P06232901
• Measurement of earth potential up to 200 VAC
• 3 measurement ranges: 20 Ω / 200 Ω / 2 000 Ω
• Data Hold
• Safety: 200 V Cat. III (IEC61010-1)
• Charge indicator for batteries (6 x 1.5 V)
• Supplied in a hard case with accessories

Dimensions in carrying case / weight: 275 x 260 x 100 mm / 550 g (including batteries)
Supplied in a hard case with: 3 leads terminated by crocodile clips (red 15m, yellow 10m and green 5 m),
1 red lead 1.20 m long terminated by a crocodile clip, 2x20 cm stakes, 1 double measurement cable
for the 2 P method and batteries.

Digital insulation tester at 1,000 V

MH 401
◆ Insulation measurement at 250 Vdc / 500 Vdc / 1,000 Vdc up to 2,000 Ω
• Timer / DATA HOLD / compensation of leads
To order
• Safety: 300 V Cat. III (IEC 61010-1)
• Voltage measurement: 0 to 600 Vac P06234101
• Continuity measurement (I > 200 mA) with buzzer
• Measurement comfort: voltage presence LED / ongoing insulation test LED 299€EX-VAT
• Automatic standby function for batteries (6 x 1.5 V)

Supplied in a hard case with 2 leads 80 cm long (red + black) terminated


by test probes plus 2 crocodile clips (red + black) connectable to test
probes and batteries.

Earth testing kit Mains socket measurement lead


To order • For measuring directly on a mains socket
• Quick implementation for reliable connections
P06233001

To order
P06239307
Carrying bag containing: 2 T-shaped stakes (18 cm),
3 measurement leads terminated by crocodile clips (20m red,
10m yellow, 5 m green), additional cable for ERT200 and 201.

8
O t her Measur em ent s

Circuit Breaker Finder Digital tachometer

CBF 01 RPM 82
◆ For simple location of fuses ◆ Automatic calibre selection
and circuit-breakers ◆ MAX, MIN, HOLD
Supplied with three adapters for: • Operation with or without contact
mains socket, B22 socket (bayonet),
• Accuracy: 0.05 % + 1 count
E27 socket (screw-in), one bag,
one 9 V battery, one operating
• Rotation speed and linear rotation speed
manual (FR/GB/D/I/E) CBF 01 CBF 01 with contact: 0.5 rpm to 19,999 rpm
Transmitter Receiver rotation without contact: 2.5 rpm to 99.999 rpm
Operating voltage 200 ~ 240 V -
linear speed: 0.05 m/min to 1,999.9 m/min
Operating frequency 50 / 60 Hz -
Indication LED Audible and visual (LED)
Power supply - 9V battery
Dimensions / Weight: 160 x 72 x 37 mm / 300 g
Sensitivity - Adjustable
Supplied with: 1 battery, 1 carrying case, 1 contact
Dimensions 80 x 50 x 31 mm 186 x 90 x 38 mm measurement adapter, 1 tapered adapter, 1 tubular
Weight Approx. 55 g Approx. 150 g adapter, 1 wheel for linear speed, reflective stickers.
Safety IEC 61010 300 V Cat. II

To order
To order P06236902
P06237001
USB temperature
Digital lightmeter and humidity recorder
LM 76 DL 53
◆ Remote-controllable probe ◆ Compact
◆ Incidence correction ◆ Customizable
◆ MAX, MIN, HOLD ◆ Easy to use
◆ Choice of measurement unit: Lux or Fc • 32,000-point memory:
16,000 readings from – 40 °C to +70 °C
• 2,000-count display
16,000 readings from 0 to 100 % RH
• Measurement range:
• Wide range of recording intervals
0 to 200,000 Lux
• Easily adjustable alarms
• No. of ranges: 4
• Min/max overrun indicator LEDs
• Accuracy: 3 %
• Simple PC connection with USB
Dimensions: Instrument: 130 x 55 x 38 mm
Dimensions / Weight: 101.5 x 30 x 30 mm / 20 g
Sensor: 125 x 86 x 35 mm
Supplied with software(1) on CD-Rom, protective cover, stick-on or screw-
Weight: 250 g
on support (screws supplied), lithium battery
Supplied with a case and a 9 V battery
(1)
Supplied with software in 5 languages (F, GB, D, I, E) compatible with the following operating systems: Windows XP & Vista (32 bits), 7, 8, 8.1
& 10 (32 & 64 bits). Windows 10, Windows 8/8.1, Windows 7, Windows Vista and Windows XP are registered trade marks of Microsoft Corporation

To order To order
P06236201 P06230801
www.multimetrix.fr 9
O t her Me asur em ent s

Cable tester for telephone, computer and video wiring

CT 51
◆ Removable transmitter module:
only one person needed for testing
• For cables: RJ-45 / RJ-11 / USB / 1394 / BNC
To order
• Testing for continuity, breaks and short-circuits
• Measurements on cables up to 180 m long P06237901

Dimensions / Weight: 200 x 100 x 27 mm / 280 g (everything included)


Supplied with cable adapters and a 9 V battery

Stud (wood/metal) and live cable detector


D 45
◆ No more blind drilling into wooden
or plasterboard walls
• Location of live electrical cables
• Detection of metal items (pipes, etc.)
and the position of wood or metal studs
• Detection depth: 30 cm
• Accuracy of indication: ± 15 mm To order
• Automatic calibration
P06237902
• Automatic shutdown

Supplied with a 12 V battery (MN21 type)


Dimensions / Weight: 130 x 65 x 35 mm / 130 g

10
L a b o ra tor y In s trum e n t s

Power Supplies

XA 1525 XA 3051
◆ Single-output DC laboratory ◆ Single-output DC laboratory
power supply power supply
• 0-15.0 VDC / 0-2.5 ADC adjustable output • 0-30.0 VDC / 0-5.0 ADC adjustable output
• Separate display of voltage • Separate display of voltage
and current settings and current settings
• Coarse and fine voltage output adjustment • Coarse and fine voltage output
• Full overload protection adjustment
• Full overload protection

To order To order
XA1525 XA3051

Multiple feeds
XA 3052 XA 3033
◆ Dual-output DC laboratory power supply ◆ Triple-output DC laboratory power supply
• Two 0-30.0 VDC / 0-5.0 ADC adjustable outputs • Two 0-30.0 VDC / 0-3.0 ADC adjustable outputs
• The 2 independent outputs can be set up in parallel to obtain 10 A and one 5 VDC / 3 ADC fixed output
• The 2 independent outputs can be set up in series to obtain 60 V • The 2 independent outputs can be set up in parallel to obtain 6 A
• Voltage and current regulation with low noise • The 2 independent outputs can be set up in series to obtain 60 V
• Full overload protection • Voltage and current output regulation with low noise
• Full overload protection

To order To order
XA3052 XA3033

www.multimetrix.fr 11
906131160 - Ed. 2 - 05/2023 - Non contractual document.

Your distributor
Photos are non-contractual. Specifications subject to modifications linked to the technological
developments. All our devices except for accessories are guaranteed for 2 years.

Groupe Chauvin Arnoux


12-16 Rue Sarah Bernhardt - 92600 Asnières-sur-Seine - France
Tel. : +33 1 44 85 44 85 - Fax : +33 1 46 27 73 89
[email protected]
www.multimetrix.fr
12