DT-7000H22V Series ATM Site Preparation and Installation Manual

Confidential material of GRG, No disclosure to unauthorized Party 1


DT-7000H22V Series ATM Site Preparation and Installation Manual

Statements
The product described in this manual is a licensed product of GRG Banking Equipment Co., Ltd.
This product conforms to the national standard Information Technology—General Specification for
Automated Teller Machine—Part 1: Device (GB/T 18789.1); safety regulations, EMC standards:
GB 4943.1, GB/T 9254, GB 17625.1; and standard for safe: GB 10409.
This equipment has been tested and found to comply with the limits for a Class A digital device,
operation of this equipment in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own expense.
To assure the safe operation of this product, carefully read the notes provided throughout the
manual as well as the contents of the manual.
Changes or modifications not expressly approved by GRG Banking could void the user's authority
to operate the equipment.
GRG Banking is not responsible for unauthorized modifications of the equipment or changes or
attachment of connecting cables or equipment which could void the user's authority to operate the
equipment. Such resulting problem will be the responsibility of the user.
GRG Banking reserves the right to change the contents of this manual without prior notice. Please
contact us for the latest product information.
Operation procedures remain the same, even if the illustrations and photographs do not agree with
entity.

All rights reserved-11/2017

Confidential material of GRG, No disclosure to unauthorized Party I


DT-7000H22V Series ATM Site Preparation and Installation Manual

Revision Record
Date Page Description
Feb.2017 All New publication;
Nov.2017 All Increase the types of CEN-L safe

Confidential material of GRG, No disclosure to unauthorized Party II


DT-7000H22V Series ATM Site Preparation and Installation Manual

Preface
Thank you for choosing the products of GRG Banking Equipment Co., Ltd, in order to assure the
safe operation of this product, please read these manuals for this product carefully.

The whole set of instructions for this product is composed of three manuals as follows:

DT-7000H22V Series ATM Operation Manual


Describes how to get the machine started, open and close the cabinet and safe door, change
password, control the multimedia voice; how errors are reported if the ATM is abnormal; operation
instructions in maintenance mode etc.

DT-7000 H22V Series ATM Site Preparation and Installation Manual


Provides the information required to prepare a site before the installation of the machine, such as
the location of installation site, power and grounding, communication cables, installing
environment etc. Furthermore, instructions on moving the ATM to the installation site, finishing
installation and testing the ATM.

DT-7000 H22V Series ATM module Manual


Describes the technical specifications, daily operations and maintenance etc. of main modules
available for H22V series ATM.

Note: Some contents may be different from the manual as a result of the update of the product or
modification of design, please refer to revision record.

Confidential material of GRG, No disclosure to unauthorized Party III


DT-7000H22V Series ATM Site Preparation and Installation Manual

Notes on Safety
To ensure the safe operation of the ATM, please carefully read the notes on safety provided below
as well as the contents of this manual. GRG Banking will not bear any responsibilities for the
damage or injuries arising from the use of the ATM that is not in accordance with the notes and the
contents provided below.

 Remove all the foreign articles inside before switching the power on,
and note if the ambient environment conforms to relevant
requirements.

 AC 220V/110V (depending on area) voltage inside. Maintenance and


repairs should only be performed by GRG recognized professional
service engineers under power-off condition.

 The socket shall be installed near the equipment and shall be easily
accessible. When the equipment is not in use for a long time, the plug
shall be pulled out to disconnect the power supply.

 The equipment has large-scale integrated circuits inside that are


highly sensitive to the static electricity. Don't remove the metal shield
for these circuit boards unless in an anti-static environment
confirmed by GRG.

 High voltage power supply. Be careful of electric shock.

If one of the following phenomena occurs, please immediately stop operating the ATM.
1. The ATM produces smoke, strange smell, or unusual noises;
2. Electric leakage occurs;
3. Water enters the ATM (Water leakage occurs on top of the ATM or the ATM is
submerged by water);
4. Unstable power supply, voltage dip, or short interrupt occurs;
5. Cards are captured by the ATM frequently;
6. The ATM is not used for a long period (more than three months) after installation;
7. A contrived damage to the ATM;
8. The ATM is placed in an environment of lampblack, steam, high humidity or heavy dust;
9. The indoor operation temperature is too high (above 40℃) or too low (under 0℃);
When the phenomena described in clause 1, 2, 3, 5, 7 occur, call for a GRG Banking service

Confidential material of GRG, No disclosure to unauthorized Party IV


DT-7000H22V Series ATM Site Preparation and Installation Manual

engineer to the site immediately for examination; when the phenomenon described in clause 6
occurs, the service engineer will decide the further usage of the ATM.

Confidential material of GRG, No disclosure to unauthorized Party V


DT-7000H22V Series ATM Site Preparation and Installation Manual

Table of Contents
Chapter 1 General Description ................................................................................................. 1

1. Product Identification ........................................................................................................ 1

Chapter 2 Installation Site Specifications ................................................................................ 2

1. Power and ground requirements ........................................................................................ 2


1.1. Input voltage requirements ................................................................................ 2
1.2. Power consumption requirements ...................................................................... 2
1.3. Power cable specifications ................................................................................. 2
1.4. Grounding requirements .................................................................................... 2
2. Communication requirements ............................................................................................ 4
2.1. 25-pin standard upstream communication cable................................................ 4
2.2. LAN communication ......................................................................................... 5
3. Environmental specifications............................................................................................. 5
3.1. Normal operating range ..................................................................................... 5
3.2. Transportation environment ............................................................................... 6
3.3. Electromagnetic compatibility(EMC) .......................................................... 6
3.4. Noise output ....................................................................................................... 6
4. Installation Site Specification ............................................................................................ 7
4.1. H22V ATM dimensions (configured with UL safe) ........................................... 7
4.2. H22V ATM dimensions (configured with CEN-L safe) .................................. 13
4.3. H22VL ATM dimensions (configured with UL safe) ...................................... 19
4.4. H22VL ATM dimensions (configured with CEN-L safe) ................................ 23
5. Installation Environment requirements ............................................................................ 27
5.1. Environment requirements ............................................................................... 27
5.2. Floor loading.................................................................................................... 27

Chapter 3 ATM Installation .................................................................................................... 28

1. Moving the ATM ............................................................................................................. 28


1.1. Packaging the ATM for shipping ..................................................................... 28
1.2. Notes for moving the ATM .............................................................................. 28
2. How to remove the packaging ......................................................................................... 28
2.1. Removing the packaging from the upper cabinet ............................................ 29
2.2. Removing the internal packaging from the safe .............................................. 31
2.3. Checking and counting all articles ................................................................... 32
3. Installing the ATM ........................................................................................................... 33
3.1. Installing H22V ............................................................................................... 33
3.2. Installing UPS .................................................................................................. 37
4. Cable connection ............................................................................................................. 39
4.1. Configured with UL safe ................................................................................. 39

Confidential material of GRG, No disclosure to unauthorized Party VI


DT-7000H22V Series ATM Site Preparation and Installation Manual

4.2. Configured with CEN-L safe ........................................................................... 41


5. System test ....................................................................................................................... 42
5.1. Preparation before test ..................................................................................... 42
5.2. Checking the ATM for failures ........................................................................ 42
5.3. Checking and Acceptance standard ................................................................. 44

Appendix A Installation Tools ....................................................................................................... 46

Appendix B Fitting decals to the ATM......................................................................................... 47

1. Decals of ATM ................................................................................................................. 47


1.1. Decals on the fascia for H22V ......................................................................... 47
1.2. Decals on the fascia for H22VL ...................................................................... 48
1.3. Specification of note cassette decal ................................................................. 48
2. Decal specifications ......................................................................................................... 49

Appendix C Securing the ATM (with UL safe)to the floor......................................................... 52

1. Floor requirements ........................................................................................................ 52


2. Fixing component specifications ..................................................................................... 52
3. Tools ................................................................................................................................ 52
4. Anchor hole position ....................................................................................................... 53
4.1. H22V ............................................................................................................... 53
4.2. H22VL ............................................................................................................. 54
5. Drill anchor hole on the floor .......................................................................................... 54
6. Securing the ATM by anchor bolts .................................................................................. 56

Appendix D Securing the ATM (with CEN-L safe)to the floor .................................................. 59

1. Floor requirements ........................................................................................................ 59


2. Fixing component specifications ..................................................................................... 59
3. Tools ................................................................................................................................ 60
4. Anchor hole position ....................................................................................................... 60
4.1. H22V (configured with CEN-L safe)............................................................... 60
4.2. H22VL (configured with CEN-L safe) ............................................................ 61
5. Drill anchor hole on the floor .......................................................................................... 61
6. Securing the ATM by anchor bolts .................................................................................. 63

Appendix E Screwing the ground feet into the safe .................................................................... 66

1. Screw the ground feet into the safe by ratchet wrench .................................................... 66
2. Screw the ground feet into the safe by adjustable wrench ............................................... 66
3. The status when the ground feet are screwed into the safe .............................................. 67

Appendix E User Feedback Form ................................................................................................ 68

Confidential material of GRG, No disclosure to unauthorized Party VII


DT-7000H22V Series ATM Site Preparation and Installation Manual

Chapter 1 General Description


This manual is intended for GRG Banking personnel, or GRG Banking customers who are required
to install the DT-7000 H22V Series ATM.
Chapter2 provide the information about site preparations and requirements. It is very important that
the site complies with the requirements specified in this document because, once the equipment has
been installed, deficiencies in site preparation or the problems caused by these deficiencies are
much more difficult to detect and correct. Failure to comply with these requirements or take proper
steps to protect equipment against risks identified in this document may cause serious damage to
the equipment.
Chapter3 describe the details about moving the ATM, the procedures for installing the ATM, and
the configuration and system test procedures for the ATM.

1. Product Identification
The equipment is identified by the nameplate, and corresponding product information is engraved
on the nameplate. The nameplate is fitted on the left side or right side of the safe. For more
information about the nameplate, please refer to the file of YT-QFM-507A.

Note: The power consumption will vary with different configurations.

Confidential material of GRG, No disclosure to unauthorized Party 1/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

Chapter 2 Installation Site Specifications

1. Power and ground requirements

1.1. Input voltage requirements


The ATM can operate in the following input voltages (unidirectional AC):
 220 - 240V~, 50Hz(depending on area)
 100 - 120V~, 50/60Hz(depending on area)
Note: Refer to the nameplate fitted on the side of ATM for the actual input voltage your ATM
should adopt.

1.2. Power consumption requirements

Stand-by Transaction
Input voltage With heater module or not
(average) (average)
Without heater module or
80 W 100 W
100 - 120V~,
heater module is not started;
50/60HZ
Heater module is started; 680W 700 W

Without heater module or


220 - 240V~, 80 W 100 W
heater module is not started;
50HZ
Heater module is started; 680 W 700W
Note: The power consumption will vary with different configurations.

1.3. Power cable specifications


The cable is wired as shown below n.
Live (Brown)

Ground (Yellow/Green)

Neutral(blue)

The equipment requires a fixed and well-grounded three-pronged outlet, the specifications are as
follows:
 Voltage between live and neutral: 220V/110V (depending on area)
 Voltage between live and ground: 220V/110V (depending on area)
 Voltage between ground and neutral: less than 3V (measure with a multimeter)

1.4. Grounding requirements

Confidential material of GRG, No disclosure to unauthorized Party 2/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

A single grounded power outlet is required.


 The grounded connection should be insulated with the neutral and conduits.
 Strong inductive electrical devices such as air conditioners, cleaners, microwave ovens
and so on must not be connected to the same power outlet that the ATM uses.
 Voltage transients, line noise, surges, sags, impulses, and spikes may be experienced
routinely or sporadically. When such phenomena occur, the protective devices such as a
manostat (700W above) or UPS may be required to ensure proper operation of the
equipment.
Recommended grounding:
The grounded connection way recommended by GRG Banking is shown in figure(a) . It is required
that the ground wire should be connected to the grounded point of the main transformer. If it is
very difficult to do so in practice, use the method shown in figure(b). The connection way shown
in figure(c)is unacceptable. The outlet should be positioned less than 1 meter from the ATM.

Confidential material of GRG, No disclosure to unauthorized Party 3/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

2. Communication requirements
Applications commonly run on TCP/IP, SDLC, X.25, and so on communication protocols; the
ATM can connect the network via LAN, dedicated line, dial-up, and so on modes. The customers
are expected to supply the cabling and external hardware, for example, network repeaters,
MODEM and communication cables. The following two cables are in common use:

2.1. 25-pin standard upstream communication cable


This cable is mostly used to connect the network on SDLC, X.25 communication protocols. The
connector plugs are standard DB25 plug, with one end is a male plug, and the other end is a female
plug. As shown in the following figures:

Overview of 25-pin communication cable

Lead 1

Wiring relation of 25-pin communication cable

Confidential material of GRG, No disclosure to unauthorized Party 4/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

Technical requirements:
1. The communication cable between the installation site of the ATM and the MODEM or
special network devices should not be more than15 meters.
2. Do not lay the cables in strong electromagnetic fields where air conditioners and motors
are fitted; the cables should also be as short as possible.
3. Connect lead 1 to the shielded lead of the communication cable.

2.2. LAN communication


This cable is mostly used to connect the network on TCP/IP communication protocol. The
connector plugs are standard RJ-45 plug, as shown in the following figures:

Overview of 8-pin communication cable

Wiring relation of 8-pin communication cable


Technical requirements:
1. The communication cable between the installation site of the ATM and the network
repeaters should not be more than 100 meters.
2. Do not lay the cables in strong electromagnetic fields where air conditioners and motors
are fitted; the cables should also be as short as possible.

3. Environmental specifications

3.1. Normal operating range


Indoor environment
(1) Temperature: 0℃ to 40℃
(2) Temperature change rate: ≤10℃ per hour
(3) Relative humidity: 20% to 95% (40℃, non-condensing)

Confidential material of GRG, No disclosure to unauthorized Party 5/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

(4) Relative humidity change rate: ≤10% per hour


Outdoor environment (only for H22V ATM)
Temperature: -35℃ to 50℃
Temperature change rate: ≤10℃ per hour
Relative humidity: 20% to 95% (40℃, non-condensing)
Relative humidity change rate: ≤10% per hour
Note:
1. In above temperature range, in order to keep the normal operation of the ATM, it is
recommended to use some auxiliary devices, for example, add the heater module under
the condition that the operating temperature is lower than 5℃.
2. Never place the ATM in an airtight room or at the draught.

3.2. Transportation environment

Transportation temperature: -20℃ to 55℃

3.3. Electromagnetic compatibility(EMC)


The ATM conforms to following directives and standards.

 EU EMC directive: 2014/30/EU, corresponding harmonized standards: EN 55032, EN


55024, EN 61000-3-2, EN 61000-3-3

 North American EMC standard: FCC Part 15, Subpart B, ICES-003

 Domestic EMC standards: GB/T9254, GB17625.1

3.4. Noise output


 Lobby ATM: ≤55dB(A) (idle); ≤60dB(A) (operating)
 Through-the-wall ATM: ≤55dB(A) (idle); ≤65dB(A) (operating)

Confidential material of GRG, No disclosure to unauthorized Party 6/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

4. Installation Site Specification

4.1. H22V ATM dimensions (configured with UL safe)


4.1.1. Packaging dimensions

(1) Packaging dimensions of ATM


Height 1995 mm(78.54 in.) ×Width 770mm(30.31in.) × Depth 1370mm(53.94in.)
Rough weight: 533.5kg (1176.2lb)
Note: a) Rough weight refers to the weight of the ATM with standard configuration and
the container, the base and other packages. More modules are configured,
heavier the ATM will be.
b) Rough weight deviation : ±3%

Confidential material of GRG, No disclosure to unauthorized Party 7/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

4.1.2. The dimensions of ATM

The height of ground feet for H22V (configured with UL safe) is 0-90mm (0-3.54in.)

If the adjustment of ground feet is over-limit, the ATM will easily fall down, which
may lead to personal injury.

Confidential material of GRG, No disclosure to unauthorized Party 8/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

4.1.3. Locations of element on the fascia

The figure below is without ground feet.


The height of ground feet for H22V (configured with UL safe) is 0-90mm (0-3.54in.)
A B C D E

Barcode Function Receipt Expanding EPP keypad


scanning keypad issue slot area (top row)
slot (top key)
Height 1435mm 1216mm 1003mm 955mm 963mm
(from base of (56.50in.) (47.87in.) (39.48in.) (37.62in. ) (37.92in.)
terminal)
Depth 275mm 238mm 200mm 114mm 143.5mm
(from the front of 10.83(in.) 9.37(in.) 7.87(in.) 4.49(in.) (5.65in.)
Frame)

F G H I J

Cash out slot Headphon Card entry Barcode Monitor


e jack slot scanning area (center)
Height 800mm 995mm 1003mm 1050mm 1195mm
(from base of (31.50in.) (39.18n.) (39.49in.) (41.34in.) (47.04in.)
terminal)
Depth 32.6mm 198mm 174mm 181mm 252mm
(from the front 1.28 (in.) 7.80(in.) 6.85(in.) 7.13(in.) 9.92(in.)
of Frame)

Front edge

Confidential material of GRG, No disclosure to unauthorized Party 9/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

4.1.4. Wall opening dimensions and requirements

1) To keep the ambient temperature near the ATM constant in cold winter,
we should prevent the air inside and outside the wall from convecting.
It is recommended to fill the gap between the wall opening and the
ATM with heat insulation materials.
2) The dimensions of the wall opening given below are based on the
condition that the height of the indoor floor is same with that of the
outdoor ground. If the heights are different, you may need to take
measures according to the actual situation. It is recommended to take
the higher ground as the datum, and then to increase the height of lower
ground. For example: When the indoor ground is lower than the outdoor
ground, you can build a platform with bricks and cement (or make a
base which can bear the required weight with more than 10mm
thickness iron) indoors; whereas you may increase the height of user
operational area outdoors, to make the indoor ground which bears the
weight of the ATM keep approximately high with the outdoor ground of
user operational area.
Note:
a) Maximum wall thickness is ≤260mm(10.24in.).

b) If the ground feet need to be screwed into the safe, please refer to Appendix
D.

4.1.4.1.With the height of ground feet 90mm (3.54in.)

The height of ground feet, which is 90mm (3.54 in.), is taken into consideration in the following
figure.
Importance: The maximum wall thickness is 260 mm (10.24 in.)

Confidential material of GRG, No disclosure to unauthorized Party 10/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

① Wall opening
② Wall opening width
③ Wall opening height
④ Height from the indoor floor
⑤ Wall thickness(≤260 mm)
⑥ Height of ground feet
⑦ The gap between the wall and the cabinet cannot be sealed

4.1.4.2.Without the ground feet

① Wall opening
② Wall opening width
③ Wall opening height
④ Height from the indoor floor
⑤ Wall thickness(≤260 mm)
⑥ The gap between the wall and the cabinet cannot be sealed

Confidential material of GRG, No disclosure to unauthorized Party 11/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

4.1.5. Installation and service clearances

Make sure the doorway and porch leading to the installation site is wide enough to pass.
Note: The height of ground feet isn't taken into consideration in the following figure.

Minimum Recommended

① Cable entrance ②Space for maintenance personnel

Confidential material of GRG, No disclosure to unauthorized Party 12/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

4.2. H22V ATM dimensions (configured with CEN-L safe)


4.2.1. Packaging dimensions

Packaging dimensions of ATM


Height 1995 mm(78.54 in.) ×Width 770mm(30.31in.) × Depth 1370mm(53.94in.)
Rough weight: 558.5kg (1231.3lb)
Note: a) Rough weight refers to the weight of the ATM with standard configuration and
the container, the base and other packages. More modules are configured,
heavier the ATM will be.
b) Rough weight deviation : ±3%

Confidential material of GRG, No disclosure to unauthorized Party 13/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

4.2.2. The dimensions of ATM

It is not allowed to fit ground feet in this ATM.

Confidential material of GRG, No disclosure to unauthorized Party 14/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

4.2.3. Locations of element on the fascia

It is not allowed to fit ground feet in this ATM.


A B C D E

Barcode Function Receipt Expanding EPP keypad


scanning keypad issue slot area (top row)
slot (top key)
Height 1435mm 1216mm 1003mm 955mm 963mm
(from base of (56.50in.) (47.87in.) (39.48in.) (37.62in. ) (37.92in.)
terminal)
Depth 275mm 238mm 200mm 114mm 143.5mm
(from the front of 10.83(in.) 9.37(in.) 7.87(in.) 4.49(in.) (5.65in.)
Frame)

F G H I J

Cash out slot Headphon Card entry Barcode Monitor


e jack slot scanning area (center)
Height 800mm 995mm 1003mm 1050mm 1195mm
(from base of (31.50in.) (39.18n.) (39.49in.) (41.34in.) (47.04in.)
terminal)
Depth 32.6mm 198mm 174mm 181mm 252mm
(from the front 1.28 (in.) 7.80(in.) 6.85(in.) 7.13(in.) 9.92(in.)
of Frame)

Front edge

Confidential material of GRG, No disclosure to unauthorized Party 15/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

4.2.4. Wall opening dimensions and requirements

1) To keep the ambient temperature near the ATM constant in cold winter,
we should prevent the air inside and outside the wall from convecting.
It is recommended to fill the gap between the wall opening and the
ATM with heat insulation materials.
2) The dimensions of the wall opening given below are based on the
condition that the height of the indoor floor is same with that of the
outdoor ground. If the heights are different, you may need to take
measures according to the actual situation. It is recommended to take
the higher ground as the datum, and then to increase the height of lower
ground. For example: When the indoor ground is lower than the outdoor
ground, you can build a platform with bricks and cement (or make a
base which can bear the required weight with more than 10mm
thickness iron) indoors; whereas you may increase the height of user
operational area outdoors, to make the indoor ground which bears the
weight of the ATM keep approximately high with the outdoor ground of
user operational area.
Note:
a) Maximum wall thickness is ≤260mm(10.24in.).

b) It is not allowed to fit ground feet in this ATM.

① Wall opening
② Wall opening width
③ Wall opening height
④ Height from the indoor floor

Confidential material of GRG, No disclosure to unauthorized Party 16/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

⑤ Wall thickness(≤260 mm)


⑥ The gap between the wall and the cabinet cannot be sealed

Confidential material of GRG, No disclosure to unauthorized Party 17/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

4.2.5. Installation and service clearances

Make sure the doorway and porch leading to the installation site is wide enough to pass.
Note: It is allowed to fit the ground feet in this ATM.

Minimum Recommended

① Cable entrance ②Space for maintenance personnel

Confidential material of GRG, No disclosure to unauthorized Party 18/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

4.3. H22VL ATM dimensions (configured with UL safe)


4.3.1. Packaging dimensions

Packaging dimensions of ATM: Height 1995 mm(78.54 in.) ×Width770 mm(30.31in.) × Depth
1112mm(43.78in.)
Rough weight: 518kg (1142.0lb)
Note:
a) Rough weight refers to the weight of the ATM with standard configuration and
the container, the base and other packages. More modules are configured,
heavier the ATM will be.

b) Rough weight deviation : ±3%

Confidential material of GRG, No disclosure to unauthorized Party 19/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

4.3.2. The dimensions of ATM

The height of ground feet for H22VL is 0-90mm (0-3.54in.)

If the adjustment of ground feet is over-limit, the ATM will easily fall down, which
may lead to personal injury.

Confidential material of GRG, No disclosure to unauthorized Party 20/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

4.3.3. Locations of element on the fascia

The figure below is without ground feet.


The height of ground feet for H22VL is 0-90mm (0-3.54in.)
A B C D E F
Barcode Function Receipt Expanding EPP Cash out
scanning keypad issue slot area keypad slot
slot (top key) (top row)
Height 1435mm 1216mm 1003mm 955mm 963mm 800mm
(from base of (56.50in.) (47.9in.) (39.49in.) (37.6in.) (37.92in.) (31.50in.)
terminal)
Depth 236mm 203mm 165mm 80mm 78mm
(from the front 9.29(in.) 7.99(in.) 6.50(in.) 3.15(in.) (3.07in.)
of Frame)

G H I J K L

Headpho Card Barcode Monitor Accessory Lower


ne jack entry scanning (center) case door cabinet
slot area lock door lock

Height 995mm 1003mm 1047mm 1195mm 1500mm 441mm


(from base of (39.2n.) (39.49n.) (41.2in.) (47.1in.) (59.06n.) (17.4in.)
terminal)
Depth 165mm 139mm 156mm 209mm
(from the front 6.50(in.) 5.47(in.) 6.14(in.) 8.23(in.)
of Frame)

Front
edge

Confidential material of GRG, No disclosure to unauthorized Party 21/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

4.3.4. Installation and service clearances

Make sure the doorway and porch leading to the installation site is wide enough to pass.
Note: The height of ground feet isn't taken into consideration in the following figure.

Minimum Recommended

① Cable entrance ②Space for maintenance personnel

Confidential material of GRG, No disclosure to unauthorized Party 22/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

4.4. H22VL ATM dimensions (configured with CEN-L safe)


4.4.1. Packaging dimensions

Packaging dimensions of ATM: Height 1995 mm(78.54 in.) ×Width770 mm(30.31in.) × Depth
1112mm(43.78in.)
Rough weight: 543kg (1197.1lb)
Note:
a) Rough weight refers to the weight of the ATM with standard configuration and
the container, the base and other packages. More modules are configured,
heavier the ATM will be.

b) Rough weight deviation : ±3%

Confidential material of GRG, No disclosure to unauthorized Party 23/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

4.4.2. The dimensions of ATM

It is not allowed to fit ground feet in this ATM.

Confidential material of GRG, No disclosure to unauthorized Party 24/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

4.4.3. Locations of element on the fascia

It is not allowed to fit ground feet in this ATM.


A B C D E F
Barcode Function Receipt Expanding EPP Cash out
scanning keypad issue slot area keypad slot
slot (top key) (top row)
Height 1435mm 1216mm 1003mm 955mm 963mm 800mm
(from base of (56.50in.) (47.9in.) (39.49in.) (37.6in.) (37.92in.) (31.50in.)
terminal)
Depth 236mm 203mm 165mm 80mm 78mm
(from the front 9.29(in.) 7.99(in.) 6.50(in.) 3.15(in.) (3.07in.)
of Frame)

G H I J K L

Headpho Card Barcode Monitor Accessory Lower


ne jack entry scanning (center) case door cabinet
slot area lock door lock

Height 995mm 1003mm 1047mm 1195mm 1500mm 441mm


(from base of (39.2n.) (39.49n.) (41.2in.) (47.1in.) (59.06n.) (17.4in.)
terminal)
Depth 165mm 139mm 156mm 209mm
(from the front 6.50(in.) 5.47(in.) 6.14(in.) 8.23(in.)
of Frame)

Front
edge

Confidential material of GRG, No disclosure to unauthorized Party 25/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

4.4.4. Installation and service clearances

Make sure the doorway and porch leading to the installation site is wide enough to pass.
Note: It is not allowed to fit ground feet in this ATM.

Minimum Recommended

① Cable entrance ②Space for maintenance personnel

Confidential material of GRG, No disclosure to unauthorized Party 26/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

5. Installation Environment requirements

5.1. Environment requirements


 At the installation site of the ATM, provide sufficient clearance behind and around the
ATM to ensure proper cooling and airflow. For example, installing exhaust fan or using
ventilating openings.
 Protect the monitor of the ATM against strong light, as this will shorten the service life of
the monitor and cause vision blur of the users. If necessary, fit the sun-shielded shed.
 Consider whether the ATM can arrive at the installation site smoothly. For example if the
transport passage indoors is wide enough for the ATM to get across? (Refer to packaging
dimensions or ATM dimensions for related information).
 Provide a single AC 110V/220V power outlet, and the distance between the outlet and
the ATM should be less than three meters. Don’t make power connection via another
outlet.

5.2. Floor loading


The ATM must be installed on a solid and level ground capable of supporting the ATM's maximum
weight. To prevent the ground from sinking after installing the equipment, it is necessary to
consider the mechanical vibration that the ATM operates to produce. (If the equipment is installed
on the floor, place it as close as possible to the pillar and crossbeam.)

Item
H22V H22VL
Model

Max. net weight 490kg(1080.3 lb.) 480 kg(1058.2lb.)

Floor loading 1460.2 kg/m2(299.1lb./ft2) 1260.5kg/m2(258.2ft2)

H22V CEN-L H22VL CEN-L

Max. net weight 515kg(1135.4lb.) 505 kg(1113.3lb.)

Floor loading 1534.7 kg/m2(314.3 lb./ft2) 1326.2kg/m2(271.6ft2)

Confidential material of GRG, No disclosure to unauthorized Party 27/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

Chapter 3 ATM Installation

1. Moving the ATM

1.1. Packaging the ATM for shipping


No matter what kind of transportation, the ATM should be covered with plastics and packaged by
cartons. For packaging dimensions, refer to section 4 in chapter 2.

1.2. Notes for moving the ATM


To reduce the chance of damaging the ATM, the ATM should be moved with its packaging intact.
 To reduce the chance of damaging the ATM, the ATM should be moved with its
packaging intact.
 Use special moving devices such as a fork-lift truck, and operate such devices by the
professionals or trained personnel.
 It is required to examine if the moving devices are proper before operating them.
 The ATM must be moved by two men at least, one steers the moving device, and the
other helps to make the transport secure.
 In the course of the moving, the moving device should be kept equable speed (less than
60 meters per minute), especially at the crook of the road, be careful to avoid overturning
the moving device.
 The ATM is best lifted 3cm from the ground in the course of the moving, not to exceed
5cm, and the forks should be inserted into the bottom of the ATM fully.
 When moving the ATM on the ground whose height is not regular, the moving device
must be lifted, but lower it as soon as the moving device has passed the higher ground, to
avoid unexpected danger.
 In the course of the moving, place the ATM on the moving device steadily.
 While pulling out the forks from the bottom of the ATM, be careful to avoid overturning
the ATM.
Caution:
a) If the personnel who move the terminal are not the qualified personnel
for carrying heavy equipment, serious injury may occur.
b) Handle the equipment with care. Do not move the equipment when the
cabinet door is open. Please make sure that the safe door is closed and
locked.
c) Be careful when moving the ATM. Keep it upright, avoid overturning.

2. How to remove the packaging


This section details how to remove the internal packaging from two different parts of the ATM
(upper cabinet and safe).

Confidential material of GRG, No disclosure to unauthorized Party 28/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

Note: 1) The keys are kept in the plastic bag and secured to the surface of the cabinet.
2) First remove the external packaging from the ATM before removing the internal packaging.
Before installing the ATM, the shipping brackets must be removed. The following figure shows the
locations of the shipping brackets inside the ATM.

2.1. Removing the packaging from the upper cabinet


Tools: cross screwdriver, cutting nipper

Remove the shipping bracket for


A B1 securing the receipt printer tray in
H22V.
H22V: Open the upper cabinet door;
H22VL: Open the lower cabinet door and
fascia lock, and then pull out the fascia.
Refer to DT-7000H22V series ATM
Operation Manual for details.

Remove the shipping bracket for


B2 securing the receipt printer tray in C
H22VL.

Remove all the tapes and foam blocks from


the upper cabinet.
Pull the receipt printer\ journal printer tray
out.

Confidential material of GRG, No disclosure to unauthorized Party 29/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

Remove the tapes and ties securing Remove the tapes securing the
E the journal printer, then restore the D receipt printer.

E
tray and lock the cabinet door or fascia.

Tie Tape

Tape

Confidential material of GRG, No disclosure to unauthorized Party 30/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

2.2. Removing the internal packaging from the safe


Tools: cross screwdriver

打开A Open the safe door. Take down the change key
A Refer to DT-7000H22V Series ATM B attached to the safe door.
Operation Manual for details. (keep the key carefully)

Remove the tap for fixing the tray of


D C the machine, and remove all foam
blocks for fixing the machine.
Tape

Detach the tie for fixing the cassettes.

Remove the shipping brackets


C securing the CDM8240N.

Confidential material of GRG, No disclosure to unauthorized Party 31/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

2.3. Checking and counting all articles


After unpacking the ATM, count all articles in accordance with the packaging list immediately and
inspect the ATM for any visible signs of damage.
The packaging list is placed in the ATM manual box, all ATM accessories are listed in the
packaging list, please count them carefully. If you find any discrepancy of article or article amount
with the packaging list, contact us as soon as possible.
After counting and checking, keep these articles carefully, in particular, keep various keys in a safe
place, and keep the packaging list for future reference.

Confidential material of GRG, No disclosure to unauthorized Party 32/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

3. Installing the ATM

3.1. Installing H22V


The installation steps are the same for H22V configure with UL and CEN-L safe, as following:
Tool: Fork-lift truck (manual or electric), open-end wrench (diameter: 8mm) or box-end wrench
(inner diameter: 8mm, hexagonal), ratchet wrench (inner diameter: 12mm, hexagonal) or
adjustable wrench, cross screwdriver (diameter: 6mm), gradienter, and glass glue.

If the ground feet are not screwed into the safe, it is not allowed to fit anchor bolts.

(1) Remove two screws securing the top pressure plates of the decorative frame (keep the
removed screws), and unplug the cables of the lamp box.

(2) Pull out the fascia, refer to H22V series ATM Operation Manual for details.

Confidential material of GRG, No disclosure to unauthorized Party 33/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

(3) Dismounting of the lower part of decorative frame: remove 2 screws on the top to disconnect
from the shutter baffle(keep the removed screws), dismount the lower part of the decorative
frame, and restore the fascia.

(4) Remove 8 screws securing the left and rights sides of the decorative frame (4 screw for each
side, keep the removed screws), and remove the left and right sides and upper part of the
decorative frame as a whole.

(5) Keep the removed parts properly.

Confidential material of GRG, No disclosure to unauthorized Party 34/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

(6) Move the ATM to the wall opening by a moving tool.


Precautions:
A. If anchor bolts are used to secure the ATM to the floor, please refer to Appendix C Securing
the ATM to the floor, otherwise proceed to the next step.
B. Handle with care when moving the equipment and always keep the equipment upright, without
inclination.

(7) Hold the left and right sides of the decorative frame to get through the wall hole, and restore
the upper part and left and right sides of the decorative frame, and then fix the left and right
sides of the decorative frame on the cabinet with 8 screws removed in step 5.

(8) Connecting cable of lamp box: Fix the top pressure plate of the decorative frame with 2
screws removed in step 1.

Confidential material of GRG, No disclosure to unauthorized Party 35/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

(9) Pull out the fascia, refer to refer to H22V series ATM Operation Manual for details.

(10) Install the lower part of the decorative frame with 2 screws removed in step 3 and restore the
fascia.

(11) Check the installation of ATM.


(a) Make sure that the ATM is on a level ground, suggest using a gradienter. If necessary,
adjust four ground feet, or fill some hard materials under the bottom of the safe.
(b) Make sure that the inside of each frame assembly is pressed against the outer wall, If
necessary, move the fork-lift truck to adjust.

Confidential material of GRG, No disclosure to unauthorized Party 36/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

(12) Apply glass glue between the decorative frame and the outer wall (for waterproofing
purpose).

Glass glue

3.2. Installing UPS


Uninterrupted Power Supply (UPS) provides emergency power when the input power supply fails,
to help the ATM to complete the last transaction. It can also stabilize the power supply by filtering
to improve the quality of the AC power supply.

UPS is an optional component independent of the complete machine. If your ATM should be
configured with UPS, please install it according to the following steps before ATM power-on.

(1) Open the UPS package, then take out the UPS and its cable;
(2) Open the ATM cabinet door or safe door, and then put the UPS to the corresponding position.
Please refer to the ATM manuals for details;
(3) Disconnect the UPS input cable and output cable, as the figure shows;

(4) Connect the UPS input cable to UPS, and then connect the signal cable to UPS, as the figure

Confidential material of GRG, No disclosure to unauthorized Party 37/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

shows;

(5) Connect  to UPS, and then connect  to UPS output cable, as the figure shows;

(6) Connect the ATM power cable, please refer to the ATM manuals for details;
(7) Switch the ATM power on.

Confidential material of GRG, No disclosure to unauthorized Party 38/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

4. Cable connection

4.1. Configured with UL safe


Power cables and communication cables connected to the ATM must conform to power and
grounding requirements, and communication requirements. The power cable shall be placed in the
accessories box when the ATM is delivered.

(1) If the installation area for the ATM is limited, connect the cable before moving the ATM to its
installation position.
(2) Turn the main switch off before connecting the cable.
(3) The power cable is places in the accessories box. The communication cable should provided
by the customers. The commonly used communication cable is LAN.
(4) H22V has two external cable entrances. The default used entrance when leaving factory is on
the left (View from the backside). The entrance on the right is shielded by a cover. When
installing the ATM, if the maintenance area on the left is not convenient enough for operating
the cable, you can use the entrance on the right. The size and structure of the cable entrance
on the left is the same as the one on the right.
The detailed connecting procedures are as follows: Tool: cross screwdriver

The ATM has two external cable Open the safe door.
A entrances on the backside or each on B Refer to DT-7000H22V Series ATM
the left and right sides. Operation Manual.

External cable
entrance.

Confidential material of GRG, No disclosure to unauthorized Party 39/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

Feed the communication cable and Use your hand to push the cable
D power cable into the cable holder. C holder out from the inside of the
safe, until it is separated from the
cable entrance.

Feed into
Cable holder

Cable entrance

Feed the communication cable and Restore cable holder


E power cable through the cable F
entrance. Connect them to the
sockets, and fix them with cable tie.

Power cable
Communication cable
Cable tie

G
Connect the power cable to the external
power supply, and power it on.

Keep the ATM in power off state


when connecting the power cable to the
external power supply.

Confidential material of GRG, No disclosure to unauthorized Party 40/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

4.2. Configured with CEN-L safe


The power supply cable is configured with the ATM, while the communication cable is not
supplied by the manufacturer. Generally speaking, the communication cable is for LAN. The
cables should be connected as follows:

Note: Make sure the ATM is power-off.

Remove the screws on the power Remove the cable holder.


A cover. B (keep the screws).

Screws

Cable holder Cable entrance

Restore screws on cover. Feed the communication cable and


D C power cable through the hole, then
connect them to the corresponding
sockets, and fix them with cable tie.
Screws

Cable tie Power cable


Communication
cable

E
Connect the power cable to the external
power supply, and power it on.
Note:
Keep the ATM in power off state when
connecting the power cable to the external
power supply.

Confidential material of GRG, No disclosure to unauthorized Party 41/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

5. System test

5.1. Preparation before test


The system test is performed to check the status of all hardware units. Test program has already
been loaded in the H22V series ATM before leaving the factory. Start up the test program
according to the following steps:

(1) Connect the power supply of the ATM.


(2) Open the upper cabinet door.
(3) Switch the power switch to “1” to power on the ATM.
(4) Process the converse steps to close the ATM cabinet.
(5) The ATM will load application program and test program automatically, along with a self-test.

5.2. Checking the ATM for failures


When the test program starts up, select the menu to enter offline operation mode and switch to
maintenance mode. Select the corresponding menu items of the maintenance mode to perform
module test (refer to DT-7000H22V Series ATM Operation Manual for detailed operation of the
maintenance mode). Test items are listed as follows (this may vary with different configurations):

 〈System Test〉->〈Card Reader〉->〈Initialization Test〉

 〈System Test〉->〈Receipt Printer〉->〈Print Test〉

 〈System Test〉->〈Journal Printer Test〉->〈Print Test〉

 〈System Test〉->〈Door Test〉->〈Initialization Test〉

 〈System Test〉->〈CDM8240N Test〉->〈Initialization Test〉

 〈System Test〉->〈Sound Test〉

 〈System Test〉->〈Keypad Test〉

 〈System Test〉->〈Network Test〉

 〈System Test〉->〈Other Test〉

Each module may have several testing items, and the operator can perform the testing according to
the menu.
If the ATM passes the test, successful information prompt will be displayed, this indicates all
hardware modules are in good condition.
If offline test fails, the ATM will display Error information prompt. By using the maintenance
mode (The menu: Error Query Hardware Error Code), service engineers or customer personnel
may find out failure causes and corresponding solutions.

Confidential material of GRG, No disclosure to unauthorized Party 42/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

(1) Replenish journal printer paper and receipt printer paper before test. Refer to DT-7000H22V
Series ATM Operation Manual for detailed installation procedures.
(2) For H22V, you should use diagnostic unit to enter maintenance mode to complete the module
test.
(3) In the testing program, the dispensing test should follow the rules and regulations about the
note cassette provided by local bank.

Confidential material of GRG, No disclosure to unauthorized Party 43/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

5.3. Checking and Acceptance standard


General Standard:
The acceptance standard for the ATM software is that the system software and application software
loaded in the ATM can operate properly. The acceptance standard for the ATM hardware is that the
ATM can pass the system test.
The detailed checking items are as follows: Total two pages
Items Checked Requirements Result Remark

(1) The external packaging is in good shape and the


color of the tilt watch indicator on the top of
the crate is normal, which shows the crate is never
overturned.
Appearance
(2) After unpacking, the appearance of the
Check
equipment and components is found to have no
signs of scratches and damages.

(3) The various parts, connector assembly and


fasteners of the equipment should be fastened.

The articles should be consistent with that specified


Configuration
in the configuring list for model, quantity and
Check
configuration.

(1) The combination lock can be set and changed.


Door (2) The key lock and combination lock are easy to
open.

(3) The cabinet door is easy to open.

(1) The system software can be installed, and


Software operates normally.

(2) The test software can be installed, and operates


normally.

(1) Every key on the keyboard is very flexible and


User Interface the number is correct.
Elements (2) The monitor can display correctly and clearly.
and
(3) The lighting and speaker are normal.
Demonstration
(4) The offline test software operates normally.

(5) Front access and rear access are normal.


CRM9250 (1) The shutter opens and closes correctly.

Confidential material of GRG, No disclosure to unauthorized Party 44/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

(2) Notes can be dispensed or deposited smoothly.

(3) The setting and operation of every note cassette


are normal.

(1) Can print accurately and clearly.


Receipt Printer
(2) Can cut paper and feed paper automatically, and
report error if paper runs out.

(1) Defective card can’t be inserted.

(2) The normal card can be inserted and ejected


Card Reader Motorized
after operation.
Card
(3) The card can be retrieved when it is not Reader
removed within an interval time.

(1) Can print accurately and clearly.


Journal Printer
(2) Can wrap paper automatically and report error
if paper runs out.

(1) Can initialize and restart normally.


Industrial PC
(2) The network communication cable is correctly
connected.

Other modules are normal.

Signature of Installation Date: Signature of Customer: Date:


Engineer:

Confidential material of GRG, No disclosure to unauthorized Party 45/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

Appendix A Installation Tools


To install the ATM, you need the following tools:

(1) Fork-lift truck (manual or electric)


(2) Open-end wrench (diameter:8mm) or box-end wrench (inner diameter:8mm, hexagonal)
(3) Cross screwdriver (diameter: 6mm)
(4) Gradienter
(5) Glass glue
(6) Cutting nippers (for package cutting)
To drill security bolt (expansion blot) and secure the ATM to the floor, you will need the following
tools:

(1) Fork-lift truck (manual or electric)


(2) 6mm diameter cross screwdriver
(3) Pencil
(4) Electric drill (Φ20mm bit , for concrete floor)
(5) Hammer
(6) Vacuum cleaner
(7) Gradienter
(8) 16mm ratchet wrench or 30mm adjustable wrench
(9) Tape
Note: For the tools without specifications, common types of tools or equivalent tools can be used.

Confidential material of GRG, No disclosure to unauthorized Party 46/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

Appendix B Fitting decals to the ATM


The decals have been fitted on the ATM before leaving the factory. When the decals need to be
replaced, refer to this chapter.

1. Decals of ATM

1.1. Decals on the fascia for H22V


The location of the decals are the same for H22V configure with UL and CEN-L safe.

1 Receipt issue & card 3 Barcode scanning area


entry slot decal decal

2\4 Palm vein/contactless IC card/ID card reading area decal

5 Cash out slot decal

Confidential material of GRG, No disclosure to unauthorized Party 47/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

1.2. Decals on the fascia for H22VL


The location of the decals are the same for H22VL configure with UL and CEN-L safe.

1 Receipt issue & card 3 Barcode scanning area


entry slot decal decal

2\4 Palm vein/contactless IC card/ID card reading area decal

5 Cash out slot decal

1.3. Specification of note cassette decal


Note cassettes in the CDM8240N have been provided with a decal to identify different currency
denomination.

Cassette decal

Confidential material of GRG, No disclosure to unauthorized Party 48/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

2. Decal specifications
If you hope to fit the decals to the ATM, refer to the following contents.

(1) Specification of cash out slot decal (H22VL)


Note:
If you want to design the decal, the maximum thickness of the decal must not exceed 0.3mm
(0.01in.), and it is suggested to use PC material.

(2) Specification of cash out slot decal (H22V)


Note:
If you want to design the decal, the maximum thickness of the decal must not exceed 0.3mm
(0.01in.), and it is suggested to use PC material.

(3) Specification of receipt issue & card entry slot decal


Note:
If you want to design the decal, the maximum thickness of the decal must not exceed 0.3mm
(0.01in.), and it is suggested to use PC material.

Confidential material of GRG, No disclosure to unauthorized Party 49/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

(4) Specification of contactless IC card reading /writing area decal


Note:
If you want to design the decal, the maximum thickness of the decal must not exceed 0.3mm
(0.01in.), and it is suggested to use PC material.

(5) Specification of ID card reading area decal


Note:
If you want to design the decal, the maximum thickness of the decal must not exceed 0.3mm
(0.01in.), and it is suggested to use PC material.

Confidential material of GRG, No disclosure to unauthorized Party 50/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

(6) Specification of barcode scanning area decal


Note:
If you want to design the decal, the maximum thickness of the decal must not exceed 0.3mm
(0.01in.), and it is suggested to use PC material.

Confidential material of GRG, No disclosure to unauthorized Party 51/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

Appendix C Securing the ATM (with UL safe)to the floor


To enhance the security of the equipment, it is recommended to secure the equipment to the floor
by using anchor bolts (not supplied with the equipment) as follows:

1. Floor requirements
It is required to install the ATM on the concrete floor. Users should make sure the floor conforms
to the following requirements:

(1) The concrete floor or base must be capable of withstanding the ATM.
(2) In order to guarantee the ATM installation, the thickness of the concrete floor or base should
be ≥180mm (7.1 in.).
(3) Make sure the concrete floor or base is as level as possible (please use the gradienter to verify
before installation).
(4) It is required to drill anchor holes for anchor bolts. Please refer to section 4 in this chapter for
the positions of the holes.

2. Fixing component specifications

4 M16*170mm anchor bolts are required for


installing the machine on the concrete floor.
Each anchor bolt consists of the following
components:
① M16*170mm bolt;
② M16 hex nut;
③ M16 spring washer (Φa=21.7mm,
Φi=16.5mm,T=3.7mm);
④ M16 washer (Φa=40mm ,
Φi=16.5mm,T=3mm);
⑤ M16*140mm expansion sleeve Anchor bolt

3. Tools
Fork-lift truck (manual or electric) Vacuum cleaner

Cross screwdriver(Diameter: 6mm) Gradienter

Pencil Ratchet wrench (inner diameter:16mm,


hexagonal) or adjustable wrench

Confidential material of GRG, No disclosure to unauthorized Party 52/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

Churn drill (20mm-diameter bit, for concrete Tape


floor)

Hammer

4. Anchor hole position


The anchor bolt position for H22V series ATM are shown as the following figures. If the anchor
holes marked on the floor are not that correct, please move the ATM to the hole positions then
re-mark according to the anchor holes on the bottom of the safe.
Note: The hole of anchor bolt is Φ22mm.

4.1. H22V

A View

① ATM front ② Space for Anchor Hole

Confidential material of GRG, No disclosure to unauthorized Party 53/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

4.2. H22VL

A View

① ATM front ② Space for Anchor Hole

5. Drill anchor hole on the floor


Mark the position of anchor holes on the concrete floor, then drill.
Note: a) Move the ATM for several times to finish the following operation.
b) If the foot bolt is not screwed into the safe, it is not allowed to fit anchor bolt.
Thus, if the ATM is fitted with foot bolts, please screw it into the safe at first
(refer to Appendix E for detail).

(1) Take the ATM installation and service area as reference.


(2) Use a pencil or other tools to mark the anchor holes on the floor (please refer to section 4 in
this chapter for the hole positions).
Note:
a) If the holes marked are not that correct, please move the ATM to the hole positions then re-mark
according to the anchor holes on the bottom of the safe.
b) Proceed step3 if you need to move the ATM to mark holes on the floor, if not, proceed step8.

(3) Remove rubber plug.

Note: Note: if necessary, remove some units and modules that affect the installation,
which should be accompanied with professional service engineers.

Confidential material of GRG, No disclosure to unauthorized Party 54/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

Rubber plug

Bottom of the Safe

(4) Use fork-lift truck (manual or electric) to move the ATM to the holes marked on the floor,
then re-mark according to the center of 4 anchor holes on the bottom of the safe.
Note: If it is the through-the-wall ATM, please operate the relative steps of Section 3, Chapter 3 in
this manual to fit it into wall hole, and mark maintenance and service areas, then proceed step 5 in
this section to make accurate hole positions.

(5) Open the safe door at a certain angle to make enough operation and service areas (please refer
to the installation and service areas of each ATM.).
Please refer to DT7000-H22V Series ATM Operation Manual to open the safe door.
Refer to Section 4.1.5in Chapter 2 for H22V maintenance and service areas.
Refer to Section 4.3.4in Chapter 2 for H22VL maintenance and service areas.

(6) In order to make the anchor bolts fall into the holes accurately, it is recommended to make
some tapes around the ATM.

H22VL H22V

(7) Close and lock the safe door, then move the ATM aside to provide enough space to drill the
holes.

Confidential material of GRG, No disclosure to unauthorized Party 55/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

Note: If it is a through-the-wall ATM, please move it out of wall hole in reverse steps of
step 4.

H22VL H22V

(8) Use a churn drill (Φ20mm bit, for concrete floor) (it is recommended to make a line on the bit
to ensure the depth holes) to drill four holes at the anchor holes marked in the previous steps.
The hole, equal with anchor bolt in size, should be approximately in the depth of 120mm.

Note: 1. All of anchor holes are up-right.


2. Observe all safety precautions for operating manual and electric tools, wear
eye and ear protection while operating the electric drill.

6. Securing the ATM by anchor bolts

(1) Use the cleaner to clean up the dirt while drilling holes.
(2) Put four M16*170 mm bolts about 1 mm deep into the holes, and then use a hammer to tap
them completely in, and make sure the bottom of bolts align with that of the holes.

Confidential material of GRG, No disclosure to unauthorized Party 56/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

① Bolt
② Hex Nut
③Spring Washer
④ Washer
⑤ Expansion Sleeve
⑥ Concrete Floor

(3) Remove the nuts, washers and spring washers of the four anchor bolts, but do not throw them
away.
(4) Use the manual or electric fork-lift truck to move the ATM, adjust its position until 4 anchor
bolts fall into the corresponding holes on the bottom of the safe.
Note: If it is through-the-wall ATM, please operate step 1)-6) of Section 3.1, Chapter 3 in this
manual to install the ATM into the wall opening.

H22VL H22V

(5) Open the safe door. (refer to DT7000-H22V Series ATM Operation Manual for details)
(6) Use the gradienter to verify if the bottom of the ATM is as level as possible with the floor.
Note: If the ATM is not installed up-right, note jam or dispense fault may occur.

Confidential material of GRG, No disclosure to unauthorized Party 57/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

Gradienter

(7) Restore the nuts, washers (supplied by the bolt manufacturer), spring washers, and Φ20
washers in order.
Note: If necessary, remove some units and modules that affect the installation, which should be
accompanied with professional service engineers.

(8) Use 16mm ratchet wrench to tighten 4 nuts, then make sure the ATM is fixed on the floor.
① Safe
② Bolt
③ Hex Nut
④ Spring Washer
⑤ Washer
⑥ Expansion
Sleeve
⑦ Concrete Floor

(9) Restore the units or modules removed, which should be accompanied with professional
service engineers.

Note: If it is through-the-wall machine, please operate as steps in Chapter 3.

Confidential material of GRG, No disclosure to unauthorized Party 58/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

Appendix D Securing the ATM (with CEN-L safe)to the


floor
To enhance the security of the equipment, it is recommended to secure the equipment to the floor
by using anchor bolts (not supplied with the equipment) as follows:
Note: According to EN1143-1 standard, the ATM with CEN-L safe should be installed on the
concrete floor, instead of wooden or iron one. If the anchoring is not possible, please connect your
insurance.

1. Floor requirements
It is required to install the ATM on the concrete floor. Users should make sure the floor conforms
to the following requirements:

(1) The concrete floor or base must be capable of withstanding the ATM.
(2) In order to guarantee the ATM installation, the thickness of the concrete floor or base should
be ≥180mm (7.1 in.).
(3) Make sure the concrete floor or base is as level as possible (please use the gradienter to verify
before installation).
(4) It is required to drill anchor holes for anchor bolts. Please refer to section 4 in this chapter for
the positions of the holes.

2. Fixing component specifications

(1) The fixing components below are supplied with the equipment.
(2) 4 M16×65 mm nuts (consist with M16 round nut and taper pin, Class A Product)
(3) 4 M16×100 mm hex screws (strengthens 8.8, steel)
(4) 4 Φ20/Φ16×50 expansion sleeve
(5) 4 Φ16 washers(Φa=29.8mm, Φi=17.3mm, t=2.8mm, steel)
Note: If the components above cannot be installed, please use 4 Φ16mm anchor bolts
(strengthens 8.8, steel) and 4 Φ16mm washers (Φ a=29.8mm, Φ i=17.3mm, t=2.8mm, steel)
① M16×65 nut
② M16×100 hex screw
③ Ø20/Ø16×50 expansion sleeve
④ Ø16 washer

Confidential material of GRG, No disclosure to unauthorized Party 59/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

Anchor bolt

3. Tools
Fork-lift truck (manual or electric) Vacuum cleaner

Cross screwdriver(Diameter: 6mm) Gradienter

Pencil Ratchet wrench (inner diameter:16mm,


hexagonal) or adjustable wrench

Churn drill (20mm-diameter bit, for concrete Tape


floor)

Hammer

4. Anchor hole position


The anchor bolt position for H22V CEN-L and H22VL CEN-L are shown as the following figures.
If the anchor holes marked on the floor are not that correct, please move the ATM to the hole
positions then re-mark according to the anchor holes on the bottom of the safe.
Note: The hole of anchor bolt is Φ22mm.

4.1. H22V (configured with CEN-L safe)

① ATM front ② Space for Anchor Hole

Confidential material of GRG, No disclosure to unauthorized Party 60/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

4.2. H22VL (configured with CEN-L safe)

① ATM front ② Space for Anchor Hole

5. Drill anchor hole on the floor


Mark the position of anchor holes on the concrete floor, then drill.
Note: a) Move the ATM for several times to finish the following operation.
b) If the foot bolt is not screwed into the safe, it is not allowed to fit anchor bolt.
Thus, if the ATM is fitted with foot bolts, please screw it into the safe at first
(refer to Appendix E for detail).

(1) Take the ATM installation and service area as reference.


(2) Use a pencil or other tools to mark the anchor holes on the floor (please refer to section 4 in
this chapter for the hole positions).
Note:
a) If the holes marked are not that correct, please move the ATM to the hole positions then re-mark
according to the anchor holes on the bottom of the safe.
b) Proceed step3 if you need to move the ATM to mark holes on the floor, if not, proceed step8.

(3) Remove rubber plug.

Note: Note: if necessary, remove some units and modules that affect the installation,
which should be accompanied with professional service engineers.

Confidential material of GRG, No disclosure to unauthorized Party 61/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

Rubber plug

Bottom of the Safe

(4) Use fork-lift truck (manual or electric) to move the ATM to the holes marked on the floor,
then re-mark according to the center of 4 anchor holes on the bottom of the safe.
Note: If it is the through-the-wall ATM, please operate the relative steps of Section 3, Chapter 3 in
this manual to fit it into wall hole, and mark maintenance and service areas, then proceed step 5 in
this section to make accurate hole positions.

(5) Open the safe door at a certain angle to make enough operation and service areas (please refer
to the installation and service areas of each ATM.).
Please refer to DT7000-H22V Series ATM Operation Manual to open the safe door.
Refer to Section 4.2.5in Chapter 2 for H22V (configured with CEN-L safe) maintenance and
service areas.
Refer to Section 4.4.4in Chapter 2 for H22VL (configured with CEN-L safe) maintenance and
service areas.

(6) In order to make the anchor bolts fall into the holes accurately, it is recommended to make
some tapes around the ATM.

H22VL (configured with CEN-L safe) H22V (configured with CEN-L safe)

Confidential material of GRG, No disclosure to unauthorized Party 62/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

(7) Close and lock the safe door, then move the ATM aside to provide enough space to drill the
holes.

Note: If it is a through-the-wall ATM, please move it out of wall hole in reverse steps of
step 4.

H22VL (configured with CEN-L safe) H22V (configured with CEN-L safe)

(8) Use a churn drill (Φ20mm bit, for concrete floor) (it is recommended to make a line on the bit
to ensure the depth holes) to drill four holes at the anchor holes marked in the previous steps.
The hole, equal with anchor bolt in size, should be approximately in the depth of 120mm.

Note: 1. All of anchor holes are up-right.


2. Observe all safety precautions for operating manual and electric tools, wear
eye and ear protection while operating the electric drill.

6. Securing the ATM by anchor bolts

(1) Use the cleaner to clean up the dirt while drilling holes.

Confidential material of GRG, No disclosure to unauthorized Party 63/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

(2) Put M16×65mm nut into the bolt hole, then insert expansion sleeve and make it align with the
floor or about 1mm deep into the hole, then use a hammer to tap the taper pin until it aligns
with the nut. Then the nut will burst open and be completely in the floor.

① Concrete floor
② Taper pin
③ M16 nut
④ Ø20×50 expansion sleeve

(3) Use the manual or electric fork-lift truck to move the ATM, adjust its position until 4 anchor
bolts fall into the corresponding holes on the bottom of the safe.
Note: If it is through-the-wall ATM, please operate step 1)-6) of Section 3.1, Chapter 3 in this
manual to install the ATM into the wall opening.

H22VL (configured with CEN-L safe) H22V (configured with CEN-L safe)

(4) Open the safe door. (refer to DT7000-H22V Series ATM Operation Manual for details)
(5) Use the gradienter to verify if the bottom of the ATM is as level as possible with the floor.

Confidential material of GRG, No disclosure to unauthorized Party 64/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

Note: If the ATM is not installed up-right, note jam or dispense fault may occur.

Gradienter

(6) Put Φ16 washer on, then tap the M16×100 screws in, and tighten 4 nuts by the adjustable
wrench to make sure the ATM is fixed on the floor.
① Concrete floor
② Taper pin
③ M16 nut
④ Ø20×50 expansion
sleeve
⑤ M16×100 screw
⑥ Ø16 washer

(7) Restore the units or modules removed, which should be accompanied with professional
service engineers.

Note: If it is through-the-wall machine, please operate as steps in section 3in Chapter 3.

Confidential material of GRG, No disclosure to unauthorized Party 65/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

Appendix E Screwing the ground feet into the safe


To ensure the ATM is as level as possible with the floor, it is necessary to screw the ground feet
into the safe completely. The detailed operation is as follows:
Tool: fork-lift truck (manual or electric), 16mm ratchet wrench or 30mm adjustable wrench
Note:
1) 16mm ratchet wrench is used when the ATM is configured with 2 cassettes or the units and
modules of the ATM are removed; 30mm adjustable wrench is used when the ATM is configured
with 4 cassettes and the units and modules are not removed.
2) All operation should be accompanied with professional service engineers.

1. Screw the ground feet into the safe by ratchet wrench


Screw the ground feet (each at the four corners) counterclockwise, and make sure they are
completely screwed into the safe.

Note:
1) Remove the units or modules that affect the operation, which should be accompanied with
professional service engineers.
2) Make sure each ground foot is tapped into the safe, otherwise, the ATM will not be up-right,
which may lead to personal injury or operation fault.

2. Screw the ground feet into the safe by adjustable wrench

(1) Lift the ATM up by the fork-lift truck.


(2) Screw the ground feet (each at the four corners) clockwise, and make sure they are completely
screwed into the safe.

Confidential material of GRG, No disclosure to unauthorized Party 66/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

Note:
(1) Make sure the cabinet door and safe door are closed firmly before lifting up the ATM.
(2) While lifting up the ATM, please keep it up-right.
(3) Make sure each ground foot is screwed into the safe, otherwise, the ATM will not be
up-right, which may lead to personal injury or operation fault.

3. The status when the ground feet are screwed into the safe
1)For the ATM configured with UL safe 2)For the ATM configured with CEN-L safe
After the ground feet are screwed in, please After the ground feet are screwed in, please
make sure it is as level as possible with the make sure it is completely screwed into the
bottom of the safe. safe.

Confidential material of GRG, No disclosure to unauthorized Party 67/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

Appendix E User Feedback Form


Title: DT-7000H22V Series ATM Site Preparation and Installation Manual
Number: DT- 7000H22V Series V1.1E-2/3 Release Date: 2017/11
GRG Banking Equipment Co., Ltd welcomes your feedback on this publication. Your comments
will be of great value in helping us to improve our products.
You may send your comments to us electronically.
Circle the numbers below that best represent your options of this publication.
Easy of Use 5 4 3 2 1 0
Accuracy 5 4 3 2 1 0
Clarity 5 4 3 2 1 0 5 = Excellent
Completeness 5 4 3 2 1 0 4 = Good
Organization 5 4 3 2 1 0 3 = Adequate
Appearance 5 4 3 2 1 0 2 = Fair
Illustrations 5 4 3 2 1 0 1 = Poor
Examples 5 4 3 2 1 0 0 = Not Applicable
Overall
5 4 3 2 1 0
Satisfaction
Choose the items you feel we will improve this publication.
□ Improve the table of contents □ Add more/better quick reference aids
□ Improve the general description □ Add more examples
□ Improve the organization □ Add more illustrations
□ Make it less technical □ Add more technical detail
□ Make it more brief □ Add more step-by-step procedures

Write any additional comments you have below (If necessary, add additional sheets.)

Thank you for your evaluation of this publication. If we may contact you concerning your
comments, please fill in the information below:
Name: Tel: Fax:
Company:
Address:
Use the following information to contact us:
Address: 9,11 Kelin Rd, Science City, High-tech Industrial Development Zone, Guangzhou, China
Postcode: 510663 Tel: +86 (0)20 62878909 Fax: +86 (0)20 62879024
Http: //www.grgbanking.com E-mail: Tech_support @grgbanking.com

Confidential material of GRG, No disclosure to unauthorized Party 68/68


DT-7000H22V Series ATM Site Preparation and Installation Manual

Confidential material of GRG, No disclosure to unauthorized Party 69/68

You might also like