Brocade Reference Guide
Brocade Reference Guide
guide
hp StorageWorks
MIB version 3.1.x/4.1.x
This guide describes the Standard MIBs, the HP Proprietary MIBs, and the Fibre Alliance MIB.
© Copyright 1999-2003 Hewlett-Packard Development Company, L.P.
Hewlett-Packard Company makes no warranty of any kind with regard to this material, including, but not limited to,
the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be liable for
errors contained herein or for incidental or consequential damages in connection with the furnishing, performance,
or use of this material.
This document contains proprietary information, which is protected by copyright. No part of this document may be
photocopied, reproduced, or translated into another language without the prior written consent of Hewlett-Packard.
The information contained in this document is subject to change without notice.
Compaq Computer Corporation is a wholly-owned subsidiary of Hewlett-Packard Company.
BROCADE, the Brocade B weave logo, Brocade: the Intelligent Platform for Networking Storage, SilkWorm, and
SilkWorm Express, are trademarks or registered trademarks of Brocade Communications Systems, Inc. or its
subsidiaries in the United States and/or in other countries.
Microsoft®, Windows®, and Windows NT® are U.S. registered trademarks of Microsoft Corporation.
Hewlett-Packard Company shall not be liable for technical or editorial errors or omissions contained herein. The
information is provided “as is” without warranty of any kind and is subject to change without notice. The warranties
for Hewlett-Packard Company products are set forth in the express limited warranty statements for such products.
Nothing herein should be construed as constituting an additional warranty.
Printed in the U.S.A.
Contents
About this Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Document Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Document Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Text Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Getting Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
HP Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
HP Storage Website . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
HP Authorized Reseller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
ifEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
ifIndex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
ifDescr. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
ifType . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
ifMtu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
ifSpeed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
ifPhysAddress . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
ifAdminStatus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
ifOperStatus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
ifLastChange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
ifInOctets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
ifInUcastPkts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
ifInNUcastPkts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
ifInDiscards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
ifInErrors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
ifInUnknownProtos. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
ifOutOctets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
ifOutUcastPkts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
ifOutNUcastPkts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
ifOutDiscards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
ifOutErrors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
ifOutQLen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
ifSpecific . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Address Translation Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Address Translation Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
atTable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
atEntry. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
atIfIndex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
atPhysAddress. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
atNetAddress. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
IP Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
ipForwarding. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
ipDefaultTTL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
ipInReceives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
ipInHdrErrors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
ipInAddrErrors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
ipForwDatagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
ipInUnknownProtos . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
ipInDiscards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
ipInDelivers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
ipOutRequests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
ipOutDiscards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
ipOutNoRoutes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
ipReasmTimeout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
ipReasmReqds. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
ipReasmOKs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
ipReasmFails. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
ipFragOKs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
ipFragFails . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
ipFragCreates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
IP Address Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
ipAddrTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
ipAddrEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
ipAdEntAdd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
ipAdEntIfIndex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
ipAdEntNetMask . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
ipAdEntBcastAddr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
ipAdEntReasmMaxSize . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
IP Routing Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
ipRouteTable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
ipRouteEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
ipRouteDest. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
ipRouteIfIndex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
ipRouteMetric1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
ipRouteMetric2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
ipRouteMetric3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
ipRouteMetric4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
ipRouteNextHop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
ipRouteType . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
ipRouteProto . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
ipRouteAge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
ipRouteMask . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
ipRouteMetric5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
ipRouteInfo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
IP Address Translation Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
ipNetToMediaTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
ipNetToMediaEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
ipNetToMediaIfIndex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
ipNetToMediaPhysAddress . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
ipNetToMediaNetAddress . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
ipNetToMediaType. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Additional IP Objects. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
ipRoutingDiscards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
ICMP Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
icmpInMsgs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
icmpInErrors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
icmpInDestUnreachs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
icmpInTimeExcds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
icmpInParmProbs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
icmpInSrcQuenchs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
icmpInRedirects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
icmpInEchos . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
icmpInEchoReps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
icmpInTimestamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
icmpInTimestampReps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
icmpInAddrMasks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
icmpInAddrMaskReps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
icmpOutMsgs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
icmpOutErrors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
icmpOutDestUnreachs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
icmpOutTimeExcds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
icmpOutParmProbs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
icmpOutSrcQuenchs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
icmpOutRedirects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
icmpOutEchos. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
icmpOutEchoReps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
icmpOutTimestamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
icmpOutTimestampReps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
icmpOutAddrMasks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
icmpOutAddrMaskReps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
TCP Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
tcpRtoAlgorithm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
tcpRtoMin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
tcpRtoMax. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
tcpMaxConn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
tcpActiveOpens. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
tcpPassiveOpens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
tcpAttemptFails. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
tcpEstabResets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
tcpCurrEstab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
tcpInSegs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
tcpOutSegs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
tcpRetransSegs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
TCP Connection Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
tcpConnTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
tcpConnEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
tcpConnState . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
tcpConnLocalAddress. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
tcpConnLocalPort . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
tcpConnRemAddress . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
tcpConnRemPort. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Additional TCP Objects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
tcpInErrs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
tcpOutRsts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
UDP Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
udpInDatagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
udpNoPorts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
udpInErrors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
udpOutDatagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
UDP Listener Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
udpTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
udpEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
udpLocalAddress . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
udpLocalPort. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
EGP Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
egpInMsg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
egpInErrors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
egpOutMsgs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
egpOutErrors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
EGP Neighbor Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
egpNeighTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
egpNeighEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
egpNeighState . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
egpNeighAddr. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
egpNeighAs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
egpNeighInMsgs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
egpNeighInErrs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
egpNeighOutMsgs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
egpNeighOutErrs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
egpNeighInErrMsgs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
egpNeighOutErrMsgs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
egpNeighStateUps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
egpNeighStateDowns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
egpNeighIntervalHello . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
egpNeighIntervalPoll . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
egpNeighMode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
egpNeighEventTrigger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Additional EGP Objects. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
egpAs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Transmission Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
SNMP Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
snmpInPkts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
snmpOutPkts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
snmpInBadVersions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
snmpInBadCommunityNames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
snmpInBadCommunityUses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
snmpInASNParseErrs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
snmpInTooBigs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
snmpInNoSuchNames. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
snmpInBadValues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
snmpInReadOnlys. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
snmpInGenErrs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
snmpInTotalReqVars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
snmpInTotalSetVars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
snmpInGetRequests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
snmpInGetNexts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
snmpInSetRequests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
snmpInGetResponses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
snmpInTraps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
snmpOutTooBigs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
snmpOutNoSuchNames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
snmpOutBadValues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
snmpOutGenErrs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
snmpOutGetRequests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
snmpOutGetNexts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
snmpOutSetRequests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
snmpOutGetResponses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
snmpOutTraps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
snmpEnableAuthenTraps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
fcFxPortRatov . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
fcFxPortEdtov . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
FxPort Class Service Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
fcFxPortCosSupported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
fcFxPortIntermixSupported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
fcFxPortStackedConnMode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
fcFxPortClass2SeqDeliv . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
fcFxPortClass3SeqDeliv . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
Other FxPort Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
fcFxPortHoldTime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
Status Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
FxPort Status Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
fcFxPortStatusTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
fcFxPortStatusEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
fcFxPortID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
fcFxPortBbCreditAvailable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
fcFxPortOperMode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
fcFxPortAdminMode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
FxPort Physical Level Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
fcFxPortPhysTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
fcFxPortPhysEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
fcFxPortPhysAdminStatus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
fcFxPortPhysOperStatus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
fcFxPortPhysLastChange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
fcFxPortPhysRttov . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
FxPort Fabric Login Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
fcFxloginTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
fcFxloginEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
fcFxPortNxLoginIndex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
fcFxPortFcphVersionAgreed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
fcFxPortNxPortBbCredit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
fcFxPortNxPortRxDataFieldSize . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
fcFxPortCosSuppAgreed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
fcFxPortIntermixSuppAgreed. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
fcFxPortStackedConnModeAgreed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
fcFxPortClass2SeqDelivAgreed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
fcFxPortClass3SeqDelivAgreed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
fcFxPortNxPortName . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
fcFxPortConnectedNxPort . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
fcFxPortBbCreditModel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
Error Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
FxPort Error Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
fcFxPortErrorTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
fcFxPortErrorEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
fcFxPortLinkFailures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
fcFxPortSyncLosses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
fcFxPortSigLosses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
fcFxPortPrimSeqProtoErrors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
fcFxPortInvalidTxWords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
fcFxPortInvalidCrcs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
fcFxPortDelimiterErrors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
fcFxPortAddressIdErrors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
fcFxPortLinkResetIns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
fcFxPortLinkResetOuts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
fcFxPortOlsIns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
fcFxPortOlsOuts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
Accounting Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
Class 1 Accounting Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
fcFxPortC1AccountingTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
fcFxPortC1AccountingEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
fcFxPortC1InFrames. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
fcFxPortC1OutFrames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
fcFxPortC1InOctets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
fcFxPortC1OutOctets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
fcFxPortC1Discards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
fcFxPortC1FbsyFrames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
fcFxPortC1FrjtFrames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
fcFxPortC1InConnections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
fcFxPortC1OutConnections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
fcFxPortC1ConnTime. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
Class 2 Accounting Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
fcFxPortC2AccountingTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
fcFxPortC2AccountingEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
fcFxPortC2InFrames. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
fcFxPortC2OutFrames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
fcFxPortC2InOctets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
fcFxPortC2OutOctets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
fcFxPortC2Discards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
fcFxPortC2FbsyFrames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
fcFxPortC2FrjtFrames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
Class 3 Accounting Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
fcFxPortC3AccountingTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
fcFxPortC3AccountingEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
fcFxPortC3InFrames. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
fcFxPortC3OutFrames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
fcFxPortC3InOctets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
fcFxPortC3OutOctets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
fcFxPortC3Discards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
Capability Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
FxPort Capability Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
fcFxPortCapTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
fcFxPortCapEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
fcFxPortCapFcphVersionHigh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
fcFxPortCapFcphVersionLow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
fcFxPortCapBbCreditMax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
fcFxPortCapBbCreditMin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
fcFxPortCapRxDataFieldSizeMax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
fcFxPortCapRxDataFieldSizeMin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
fcFxPortCapCos . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
fcFxPortCapIntermix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
fcFxPortCapStackedConnMode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
fcFxPortCapClass2SeqDeliv. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
fcFxPortCapClass3SeqDeliv. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131
fcFxPortCapHoldTimeMax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131
fcFxPortCapHoldTimeMin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131
FCFABRIC-ELEMENT-MIB (experimental branch) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
FCFABRIC-ELEMENT-MIB Organization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
Definitions for FCFABRIC-ELEMENT-MIB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
Configuration Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139
fcFabricName . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
fcElementName. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
fcFeModuleCapacity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
fc Fabric Element Module Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
fcFeModuleTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
fcFeModuleEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
fcFeModuleIndex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
fcFeModuleDescr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
fcFeModuleObjectID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
fcFeModuleOperStatus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
fcFeModuleLastChange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
fcFeModuleFxPortCapacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
fcFeModuleName . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
FxPort Configuration Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143
fcFxConfTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143
fcFxConfEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143
fcFxConfModuleIndex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143
fcFxConfFxPortIndex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143
fcFxPortName . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
fcFxPortFcphVersionHigh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
fcFxPortFcphVersionLow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
fcFxPortBbCredit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
fcFxPortRxBufSize . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
fcFxPortRatov . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
fcFxPortEdtov . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
fcFxPortCosSupported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
fcFxPortIntermixSupported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
fcFxPortStackedConnMode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
fcFxPortClass2SeqDeliv . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146
fcFxPortClass3SeqDeliv . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146
fcFxPortHoldTime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146
fcFxPortBaudRate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146
fcFxPortMedium . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
fcFxPortTxType . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
fcFxPortDistance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
Operation Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
FxPort Operation Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
fcFxPortOperTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
fcFxPortOperEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
fcFxPortOperModuleIndex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
fcFxPortOperFxPortIndex. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
fcFxPortID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
fcFPortAttachedPortName . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
fcFPortConnectedPort. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
fcFxPortBbCreditAvailable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
fcFxPortOperMode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
fcFxPortAdminMode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
FxPort Physical Level Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
fcFxPortPhysTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
fcFxPortPhysEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
fcFxPortPhysModuleIndex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
fcFxPortPhysFxPortIndex. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
fcFxPortPhysAdminStatus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
fcFxPortPhysOperStatus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
fcFxPortPhysLastChange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
fcFxPortPhysRttov . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
FxPort Fabric Login Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
fcFxlogiTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
fcFxlogiEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
fcFxlogiModuleIndex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
fcFxlogiFxPortIndex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
fcFxlogiNxPortIndex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
fcFxPortFcphVersionAgreed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153
fcFxPortNxPortBbCredit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153
fcFxPortNxPortRxDataFieldSize . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153
fcFxPortCosSuppAgreed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153
fcFxPortIntermixSuppAgreed. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154
fcFxPortStackedConnModeAgreed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154
fcFxPortClass2SeqDelivAgreed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154
fcFxPortClass3SeqDelivAgreed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
fcFxPortNxPortName . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
fcFxPortConnectedNxPort . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
fcFxPortBbCreditModel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
Error Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156
FxPort Error Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156
fcFxPortErrorTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156
fcFxPortErrorEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156
fcFxPortErrorModuleIndex. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156
fcFxPortErrorFxPortIndex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157
fcFxPortLinkFailures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157
fcFxPortSyncLosses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157
fcFxPortSigLosses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157
fcFxPortPrimSeqProtoErrors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157
fcFxPortInvalidTxWords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157
fcFxPortInvalidCrcs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158
fcFxPortDelimiterErrors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158
fcFxPortAddressIdErrors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158
fcFxPortLinkResetIns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158
fcFxPortLinkResetOuts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158
fcFxPortOlsIns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158
fcFxPortOlsOuts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158
Accounting Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
Capability Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
FxPort Capability Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
fcFxPortCapTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
fcFxPortCapEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
fcFxPortCapModuleIndex. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
fcFxPortCapFxPortIndex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
fcFxPortCapFcphVersionHigh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
fcFxPortCapFcphVersionLow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
fcFxPortCapBbCreditMax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
fcFxPortCapBbCreditMin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
fcFxPortCapRxDataFieldSizeMax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
fcFxPortCapRxDataFieldSizeMin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
fcFxPortCapCos . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161
fcFxPortCapIntermix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161
fcFxPortCapStackedConnMode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161
fcFxPortCapClass2SeqDeliv. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161
fcFxPortCapClass3SeqDeliv. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162
fcFxPortCapHoldTimeMax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162
fcFxPortCapHoldTimeMin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162
fcFxPortCapBaudRates. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162
fcFxPortCapMedia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162
PhysicalIndex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166
PhysicalClass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166
SnmpEngineIdOrNone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168
Entity MIB Objects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168
The Physical Entity Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
entPhysicalTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
entPhysicalEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
entPhysicalIndex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
entPhysicalDescr. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170
entPhysicalVendorType . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170
entPhysicalContainedIn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170
entPhysicalClass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171
entPhysicalParentRelPos. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171
entPhysicalName. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173
entPhysicalHardwareRev . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173
entPhysicalFirmwareRev . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174
entPhysicalSoftwareRev . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174
entPhysicalSerialNum. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175
entPhysicalMfgName . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175
entPhysicalModelName . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176
entPhysicalAlias . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176
entPhysicalAssetID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177
entPhysicalIsFRU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178
The Logical Entity Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179
entLogicalTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179
entLogicalEntry. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179
entLogicalIndex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179
entLogicalDescr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179
entLogicalType . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179
entLogicalCommunity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180
entLogicalTAddress . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181
entLogicalTDomain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181
entLogicalContextEngineID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182
entLogicalContextName . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182
The Entity Mapping Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182
entLPMappingTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182
entLPMappingEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183
entLPPhysicalIndex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184
entAliasMappingTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184
entAliasMappingEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184
entAliasLogicalIndexOrZero . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184
entAliasMappingIdentifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185
entPhysicalContainsTable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186
entPhysicalContainsEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186
entPhysicalChildIndex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187
The General Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187
entLastChangeTime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187
Entity MIB Trap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188
entConfigChange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188
Entity MIB Conformance Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189
entityCompliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189
entity2Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189
entityPhysicalGroup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191
entityLogicalGroup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191
entityMappingGroup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191
entityGeneralGroup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192
entityNotificationsGroup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192
entityPhysical2Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192
entityLogical2Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192
swFirmwareVersion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212
swOperStatus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213
swAdmStatus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214
swTelnetShellAdmStatus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215
swSsn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215
Flash Administration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215
Method 1:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216
Method 2:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216
swFlashDLOperStatus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216
swFlashDLAdmStatus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217
swFlashDLHost. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217
swFlashDLUser. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218
swFlashDLFile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218
swFlashDLPassword. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218
swBeaconOperStatus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218
swBeaconAdmStatus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219
swDiagResult . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219
swNumSensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219
swSensorTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220
swSensorEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220
swSensorIndex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220
swSensorType . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220
swSensorStatus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220
swSensorValue . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221
swSensorInfo. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222
swTrackChangesInfo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222
swID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223
swEtherIPAddress. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223
swEtherIPMask . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223
swFCIPAddress. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223
swFCIPMask. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223
Fabric Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224
swDomainID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224
swPrincipalSwitch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224
swNumNbs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224
swNbTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224
swNbEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224
swNbIndex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225
swNbMyPort . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225
swNbRemDomain. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225
swNbRemPort . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225
swNbBaudRate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226
swNbIslState . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226
swNbIslCost . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226
swNbRemPortName . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226
swFabricMemTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226
swFabricMemEntry. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227
swFabricMemWwn. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227
swFabricMemDid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227
swFabricMemName . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227
swFabricMemEIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227
swFabricMemFCIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227
swFabricMemGWIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227
swFabricMemType . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228
swFabricMemShortVersion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228
SW Agent Configuration Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229
swAgtCmtyTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229
swAgtCmtyEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229
swAgtCmtyIdx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229
swAgtCmtyStr. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229
swAgtTrapRcp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230
Fibre Channel Port Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231
swFCPortCapacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231
swFCPortTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231
swFCPortEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231
swFCPortIndex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231
swFCPortType . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232
swFCPortPhyState . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233
swFCPortOpStatus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233
swFCPortAdmStatus. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234
swFCPortLinkState . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234
swFCPortTxType . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235
swFCPortTxWords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235
swFCPortRxWords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235
swFCPortTxFrames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235
swFCPortRxFrames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235
swFCPortRxC2Frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235
swFCPortRxC3Frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236
swFCPortRxLCs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236
swFCPortRxMcasts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236
swFCPortTooManyRdys. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236
swFCPortNoTxCredits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236
swFCPortRxEncInFrs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236
swFCPortRxCrcs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236
swFCPortRxTruncs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237
swFCPortRxTooLongs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237
swFCPortRxBadEofs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237
swFCPortRxEncOutFrs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237
swFCPortRxBadOs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237
swFCPortC3Discards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237
swFCPortMcastTimedOuts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237
swFCPortTxMcasts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238
swFCPortLipIns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238
swFCPortLipOuts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238
swFCPortLipLastAllpa . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238
swFCPortWwn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238
swFCPortSpeed. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238
swFCPortName . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239
Name Server Database Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240
swNsLocalNumEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240
swNsLocalTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240
swNsLocalEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240
swNsEntryIndex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240
swNsPortID. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240
swNsPortType. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240
swNsPortName . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241
swNsPortSymb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241
swNsNodeName . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241
swNsNodeSymb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241
swNsIPA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241
swNsIpAddress . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242
swNsCos . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242
swNsFc4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242
swNsIpNxPort. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242
swNsWwn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242
swNsHardAddr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242
Event Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243
swEventTrapLevel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243
swEventNumEntries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243
swEventTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243
swEventEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244
swEventIndex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244
swEventTimeInfo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244
swEventLevel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244
swEventRepeatCount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245
swEventDescr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245
Fabric Watch Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246
swFwFabricWatchLicense . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246
swFwClassAreaTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246
swFwClassAreaEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246
swFwClassAreaIndex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246
swFwWriteThVals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 247
swFwDefaultUnit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 247
swFwDefaultTimebase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 247
swFwDefaultLow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248
swFwDefaultHigh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248
swFwDefaultBufSize . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248
swFwCustUnit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248
swFwCustTimebase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248
swFwCustLow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248
swFwCustHigh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 249
swFwCustBufSize. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 249
swFwThLevel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 249
swFwWriteActVals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250
swFwDefaultChangedActs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250
swFwDefaultExceededActs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250
swFwDefaultBelowActs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250
swFwDefaultAboveActs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251
swFwDefaultInBetweenActs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251
swFwCustChangedActs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251
swFwCustExceededActs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251
swFwCustBelowActs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251
swFwCustAboveActs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251
swFwCustInBetweenActs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251
swFwValidActs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251
swFwActLevel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252
swFwThresholdTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252
swFwThresholdEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252
swFwThresholdIndex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253
swFwStatus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253
swFwName . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254
swFwLabel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256
swFwCurVal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256
swFwLastEvent. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256
swFwLastEventVal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256
swFwLastEventTime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256
swFwLastState . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256
swFwBehaviorType . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257
swFwBehaviorInt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257
End Device Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 258
swEndDeviceRlsTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 258
swEndDeviceRlsEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 258
swEndDevicePort . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 258
swEndDeviceAlpa. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 258
swEndDevicePortID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259
swEndDeviceLinkFailure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259
swEndDeviceSyncLoss. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259
swEndDeviceSigLoss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259
swEndDeviceProtoErr. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259
swEndDeviceInvalidWord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259
swEndDeviceInvalidCRC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259
All Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260
swGroupTable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260
swGroupEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260
swGroupIndex. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260
swGroupName . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260
swGroupType . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260
swGroupMemTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260
swGroupMemEntry. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261
swGroupID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261
swGroupMemWwn. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261
swGroupMemPos . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261
StorageWorks 2 Gb SAN Switches ASIC Performance Monitoring Group . . . . . . . . . . . . 262
swBlmPerfALPAMntTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262
swBlmPerfALPAMntEntry. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262
swBlmPerfAlpaPort . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262
swBlmPerfAlpaIndx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262
swBlmPerfAlpa. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262
swBlmPerfAlpaCRCCnt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263
swBlmPerfEEMntTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263
swBlmPerfEEMntEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263
swBlmPerfEEPort . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263
swBlmPerfEERefKey . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263
swBlmPerfEECRC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263
swBlmPerfEEFCWRx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264
swBlmPerfEEFCWTx. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264
swBlmPerfEESid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264
swBlmPerfEEDid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264
swBlmPerfFltMntTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264
swBlmPerfFltMntEntry. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264
swBlmPerfFltPort . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264
swBlmPerfFltRefkey. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 265
swBlmPerfFltCnt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 265
swBlmPerfFltAlias . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 265
Trunking Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 266
swSwitchTrunkable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 266
swTrunkTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 266
swTrunkEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 266
swTrunkPortIndex. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 266
swTrunkGroupNumber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 266
swTrunkMaster . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 267
swPortTrunked . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 267
swTrunkGrpTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 267
swTrunkGrpEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 267
swTrunkGrpNumber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 267
swTrunkGrpMaster . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 267
swTrunkGrpTx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268
swTrunkGrpRx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268
systemURL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 287
Connectivity Unit Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 288
connUnitTable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 288
connUnitEntry. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 288
connUnitId . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 288
connUnitGlobalId . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 289
connUnitType . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290
connUnitNumports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290
connUnitState . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291
connUnitStatus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291
connUnitProduct . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292
connUnitSn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292
connUnitUpTime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292
connUnitUrl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292
connUnitDomainId . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293
connUnitProxyMaster . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293
connUnitPrincipal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293
connUnitNumSensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294
connUnitStatusChangeTime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294
connUnitConfigurationChangeTime. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294
connUnitNumRevs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 295
connUnitNumZones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 295
connUnitModuleId . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 295
connUnitName . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 295
connUnitInfo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 296
connUnitControl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 296
connUnitContact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 298
connUnitLocation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 298
connUnitEventFilter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 298
connUnitNumEvents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 298
connUnitMaxEvents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299
connUnitEventCurrID. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299
Connectivity Unit Revisions Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299
connUnitRevsTable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299
connUnitRevsEntry. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299
connUnitRevsUnitId . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300
connUnitRevsIndex. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300
connUnitRevsRevId . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300
connUnitRevsDescription . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300
Connectivity Unit Sensor Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301
connUnitSensorTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301
connUnitSensorEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301
connUnitSensorUnitId . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301
connUnitSensorIndex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301
connUnitSensorName . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301
connUnitSensorStatus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302
connUnitSensorInfo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302
connUnitSensorMessage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302
connUnitSensorType. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 303
connUnitSensorCharacteristic. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 303
Connectivity Unit Port Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304
connUnitPortTable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304
connUnitPortEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304
connUnitPortUnitId. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 305
connUnitPortIndex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 305
connUnitPortType. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 306
connUnitPortFCClassCap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 307
connUnitPortFCClassOp. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 307
connUnitPortState . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 308
connUnitPortStatus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 308
connUnitPortTransmitterType . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 309
connUnitPortModuleType . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 309
connUnitPortWwn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 310
connUnitPortFCId. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 310
connUnitPortSn. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 310
connUnitPortRevision. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 311
connUnitPortVendor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 311
connUnitPortSpeed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 311
connUnitPortControl. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 311
connUnitPortName . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 314
connUnitPortPhysicalNumber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 314
connUnitPortStatObject . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 315
connUnitPortProtocolCap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 315
connUnitPortProtocolOp. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316
connUnitPortNodeWwn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 317
connUnitPortHWState . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 318
connUnitPortStatCountRxElements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 332
connUnitPortStatCountBBCreditZero . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 332
connUnitPortStatCountInputBuffersFull . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 332
connUnitPortStatCountFBSYFrames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333
connUnitPortStatCountPBSYFrames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333
connUnitPortStatCountFRJTFrames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333
connUnitPortStatCountPRJTFrames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 334
connUnitPortStatCountClass1RxFrames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 334
connUnitPortStatCountClass1TxFrames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 334
connUnitPortStatCountClass1FBSYFrames. . . . . . . . . . . . . . . . . . . . . . . . . . . 335
connUnitPortStatCountClass1PBSYFrames. . . . . . . . . . . . . . . . . . . . . . . . . . . 335
connUnitPortStatCountClass1FRJTFrames . . . . . . . . . . . . . . . . . . . . . . . . . . . 335
connUnitPortStatCountClass1PRJTFrames . . . . . . . . . . . . . . . . . . . . . . . . . . . 336
connUnitPortStatCountClass2RxFrames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 336
connUnitPortStatCountClass2TxFrames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 336
connUnitPortStatCountClass2FBSYFrames. . . . . . . . . . . . . . . . . . . . . . . . . . . 337
connUnitPortStatCountClass2PBSYFrames. . . . . . . . . . . . . . . . . . . . . . . . . . . 337
connUnitPortStatCountClass2FRJTFrames . . . . . . . . . . . . . . . . . . . . . . . . . . . 338
connUnitPortStatCountClass2PRJTFrames . . . . . . . . . . . . . . . . . . . . . . . . . . . 338
connUnitPortStatCountClass3RxFrames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 338
connUnitPortStatCountClass3TxFrames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 339
connUnitPortStatCountClass3Discards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 339
connUnitPortStatCountRxMulticastObjects . . . . . . . . . . . . . . . . . . . . . . . . . . . 339
connUnitPortStatCountTxMulticastObjects . . . . . . . . . . . . . . . . . . . . . . . . . . . 339
connUnitPortStatCountRxBroadcastObjects . . . . . . . . . . . . . . . . . . . . . . . . . . 339
connUnitPortStatCountTxBroadcastObjects . . . . . . . . . . . . . . . . . . . . . . . . . . 340
connUnitPortStatCountRxLinkResets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 340
connUnitPortStatCountTxLinkResets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 340
connUnitPortStatCountNumberLinkResets . . . . . . . . . . . . . . . . . . . . . . . . . . . 340
connUnitPortStatCountRxOfflineSequences . . . . . . . . . . . . . . . . . . . . . . . . . . 341
connUnitPortStatCountTxOfflineSequences . . . . . . . . . . . . . . . . . . . . . . . . . . 341
connUnitPortStatCountNumberOfflineSequences . . . . . . . . . . . . . . . . . . . . . . 341
connUnitPortStatCountLinkFailures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 341
connUnitPortStatCountInvalidCRC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 342
connUnitPortStatCountInvalidTxWords. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 342
connUnitPortStatCountPrimitiveSequenceProtocolErrors . . . . . . . . . . . . . . . . 342
connUnitPortStatCountLossofSignal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 343
connUnitPortStatCountLossofSynchronization . . . . . . . . . . . . . . . . . . . . . . . . 343
connUnitPortStatCountInvalidOrderedSets . . . . . . . . . . . . . . . . . . . . . . . . . . . 343
connUnitPortStatCountFramesTooLong . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 343
connUnitPortStatCountFramesTruncated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 344
connUnitPortStatCountAddressErrors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 344
connUnitPortStatCountDelimiterErrors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 344
connUnitPortStatCountEncodingDisparityErrors. . . . . . . . . . . . . . . . . . . . . . . 344
Service Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 346
Connectivity Unit Service Scalars Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 346
connUnitSnsMaxEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 346
Connectivity Unit Service Tables Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 346
connUnitSnsTable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 346
connUnitSnsEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 346
connUnitSnsId. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 347
connUnitSnsPortIndex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 347
connUnitSnsPortIdentifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 347
connUnitSnsPortName . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 347
connUnitSnsNodeName . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 347
connUnitSnsClassOfSvc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 347
connUnitSnsNodeIPAddress. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 348
connUnitSnsProcAssoc. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 348
connUnitSnsFC4Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 348
connUnitSnsPortType . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 348
connUnitSnsPortIPAddress. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 348
connUnitSnsFabricPortName . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 348
connUnitSnsHardAddress. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 348
connUnitSnsSymbolicPortName . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 348
connUnitSnsSymbolicNodeName . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 349
SNMP Trap Registration Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 350
trapMaxClients . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 350
trapClientCount. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 350
trapRegTable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 350
trapRegEntry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 350
trapRegIpAddress . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 350
trapRegPort . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351
trapRegFilter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351
trapRegRowState . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351
Revision Number Scalar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 353
revisionNumber. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 353
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .391
Figures
1 MIB-II Overall Tree Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
2 Tree Structure for MIB-II System, Interfaces, AT, and IP groups . . . . . . . . . . . . . . . . . 41
3 Tree Structure for MIB-II ICMP, TCP, UDP, and EGP groups . . . . . . . . . . . . . . . . . . . 42
4 Tree Structure for MIB-II SNMP group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
5 FIBRE-CHANNEL-FE-MIB Overall Tree Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
6 Tree Structure for fcFeConfig and fcFeError Tables. . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
7 Tree Structure for fcFeStatus and fcFeCapabilities Tables . . . . . . . . . . . . . . . . . . . . . . 100
8 Tree Structure for fcFeAccounting Tables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
9 FCFABRIC-ELEMENT-MIB Overall Tree Structure. . . . . . . . . . . . . . . . . . . . . . . . . . 133
10 Tree Structure for fcFeConfig . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
11 Tree Structure for fcFeOpTables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135
12 Tree Structure for fcFeError, fcFeAcct, and fcFeCap Tables . . . . . . . . . . . . . . . . . . . . 136
Tables
1 Document Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
2 MIB-II Textual Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
3 FE MIBs and Supported Fabric OS Versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
4 FIBRE-CHANNEL-FE-MIB Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
5 FCFABRIC-ELEMENT-MIB Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
6 Objects Imported into the entityMIB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166
7 Possible values for PhysicalClass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167
8 SW-MIB Textual Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202
9 swFwName Objects and Object Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254
10 Objects Imported into the HA-MIB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271
11 FCMGMT-MIB Definitions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 285
12 connUnitLinkUnitTypeY End Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 328
13 TrapRegRowState for Read/Write . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 352
14 MIB Object Name/OID Matrix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 366
Overview
This section covers the following topics:
■ Intended Audience
■ Document Structure
■ Related Documentation
Intended Audience
This book is intended for use by administrators and technicians who are
experienced with the following:
■ Networking technologies
■ Fibre Channel technologies
■ SAN technologies
Document Structure
This reference book is organized into the following three sections:
Section I, Standard MIBs
■ Chapter 1, MIB-II (RFC1213-MIB)
■ Chapter 2, FE MIB Objects
■ Chapter 3, Entity MIB Objects
Section II, HP Proprietary MIBs
■ Chapter 4, SW-MIB Objects
■ Chapter 5, High Availability MIB Objects
Section III, Fibre Alliance MIB
■ Chapter 6, Fibre Alliance MIB Objects
Related Documentation
For a list of related documents included with this product, see the Related
Documents section of the Release Notes that came with your switch.
For the latest information, documentation, and firmware releases, please visit the
following StorageWorks website: http://www.hp.com/country/us/eng/
prodserv/storage.html.
For information about Fibre Channel standards, visit the Fibre Channel Industry
Association website located at: http://www.fibrechannel.org
Conventions
Conventions consist of the following:
■ Document Conventions
■ Text Symbols
■ Getting Help
Document Conventions
The document conventions included in Table 1 apply in most cases.
Table 1: Document Conventions
Element Convention
Cross-reference links Blue text: Figure 1
Key and field names, menu items, Bold
buttons, and dialog box titles
File names, application names, and text Italics
emphasis
User input, command and directory Monospace font
names, and system responses (output COMMAND NAMES are uppercase
and messages) monospace font unless they are
case-sensitive
Variables <monospace, italic font>
Website addresses Blue, underlined sans serif font text:
http://www.hp.com
Text Symbols
The following symbols may be found in the text of this guide. They have the
following meanings.
WARNING: Text set off in this manner indicates that failure to follow
directions in the warning could result in bodily harm or death.
Caution: Text set off in this manner indicates that failure to follow directions
could result in damage to equipment or data.
Note: Text set off in this manner presents commentary, sidelights, or interesting points
of information.
Getting Help
If you still have a question after reading this guide, contact an HP authorized
service provider or access our website: http://www.hp.com.
HP Technical Support
Telephone numbers for worldwide technical support are listed on the following
HP website: http://www.hp.com/support/. From this website, select the country
of origin.
HP Storage Website
The HP website has the latest information on this product, as well as the latest
drivers. Access storage at: http://www.hp.com/country/us/eng/prodserv/
storage.html. From this website, select the appropriate product or solution.
HP Authorized Reseller
For the name of your nearest HP authorized reseller:
■ In the United States, call 1-800-345-1518
■ In Canada, call 1-800-263-5868
■ Elsewhere, see the HP website for locations and telephone numbers:
http://www.hp.com.
Overview
The descriptions of each of the MIB variables in this chapter come directly from
the MIB-II itself. The notes that follow the descriptions typically pertain to
HP-specific information and are provided by HP.
The objects in MIB-II are organized into the following groupings:
■ System Group
■ Interfaces Group
■ Address Translation Group
■ IP Group
■ ICMP Group
■ TCP Group
■ UDP Group
■ EGP Group
■ Transmission Group
■ SNMP Group
Figure 2: Tree Structure for MIB-II System, Interfaces, AT, and IP groups
Figure 3: Tree Structure for MIB-II ICMP, TCP, UDP, and EGP groups
- snmp (1.3.6.1.2.1.11)
- snmpInPkts (1)
- snmpOutPkts (2)
- snmpInBadVersions (3)
- snmpInBadCommunityNames (4)
- snmpInBadCommunityUses (5)
- snmpInASNParseErrs (6)
- snmpInTooBigs (8)
- snmpInNoSuchNames (9)
- snmpInBadValues (10)
- snmpInReadOnlys (11)
- snmpInGenErrs (12)
- snmpInTotalReqVars (13)
- snmpInTotalSetVars (14)
- snmpInGetRequests (15)
- snmpInGetNexts (16)
- snmpInSetRequests (17)
- snmpInGetResponses (18)
- snmpInTraps (19)
- snmpOutTooBigs (20)
- snmpOutNoSuchNames (21)
- snmpOutBadValues (22)
- snmpOutGenErrs (24)
- snmpOutGetRequests (25)
- snmpOutGetNexts (26)
- snmpOutSetRequests (27)
- snmpOutGetResponses (28)
- snmpOutTraps (29)
- snmpEnableAuthenTraps (30)
Figure 4: Tree Structure for MIB-II SNMP group
Textual Conventions
Table 2 lists the textual conventions used for MIB-II.
Table 2: MIB-II Textual Conventions
Type Definition Value
DisplayString Octet String of size 0 to 255
PhysAddress Octet String
Imports
The following objects and types are imported from RFC1155-SMI:
■ mgmt
■ NetworkAddress
■ IpAddress
■ Counter
■ Gauge
■ TimeTicks
System Group
Implementation of the System Group is mandatory for all systems. If an agent is
not configured to have a value for any of the System Group variables, a
zero-length string is returned.
sysDescr
OID 1.3.6.1.2.1.1.1
Description A textual description of the entity.
Note: This value should include the full name and version identification of the system’s
hardware type, software operating-system, and networking software. It is mandatory
that this only contain printable ASCII characters.
sysObjectID
OID 1.3.6.1.2.1.1.2
Description The vendor’s authoritative identification of the network
management subsystem contained in the entity.
Note: This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and
provides an easy and unambiguous means for determining what kind of box is being
managed.
Example:
If vendor “Flintstones, Inc.” was assigned the subtree 1.3.6.1.4.1.4242, it could assign
the identifier 1.3.6.1.4.1.4242.1.1 to its “Fred Router.”
Default value =
iso.org.dod.internet.private.enterprises.bcsi.commDev.fibrechannel.fcSwitch.sw
sysUpTime
OID 1.3.6.1.2.1.1.3
Description The time (in hundredths of a second) since the network
management portion of the system was last re-initialized.
sysContact
OID 1.3.6.1.2.1.1.4
Description The textual identification of the contact person for this
managed node, together with information on how to contact
this person.
sysName
OID 1.3.6.1.2.1.1.5
Description An administratively-assigned name for this managed node.
By convention, this is the node’s fully-qualified domain name.
sysLocation
OID 1.3.6.1.2.1.1.6
Description The physical location of this node (for example, telephone
closet, 3rd floor).
Note: Default value = End User Premise. Set this value using the agtcfgSet telnet
command.
sysServices
OID 1.3.6.1.2.1.1.7
Description A value that indicates the set of services that this entity
primarily offers.
The value is a sum. This sum initially takes the value zero.
Then, for each layer, L, in the range 1 through 7, for which
this node performs transactions, 2 raised to (L - 1) is added to
the sum. For example, a node that primarily performs routing
functions has a value of 4 (23-1). In contrast, a node that is a
host and offers application services, has a value of 72 (24-1 +
27-1). Note that in the context of the Internet suite of
protocols, values should be calculated accordingly:
Layer functionality
1 = physical. (For example, repeaters)
2 = datalink/subnetwork. (For example, bridges)
3 = internet. (For example, IP gateways)
4 = end-to-end. (For example, IP hosts)
7 = applications. (For example, mail relays)
Note: For systems including OSI protocols, layers 5 and 6 may also be counted. The
return value is always 79.
Interfaces Group
Implementation of the Interfaces group is mandatory for all systems.
ifNumber
OID 1.3.6.1.2.1.2.1
Description The number of network interfaces (regardless of their current
state) present on this system.
Note: When running FCIP, the return value is always 3. If not running FCIP, the value
is 2.
Interfaces Table
The Interfaces table contains information on the entity’s interfaces. Each interface
is thought of as being attached to a subnetwork. Note that this term should not be
confused with subnet, which refers to an addressing partitioning scheme used in
the Internet suite of protocols.
ifTable
OID 1.3.6.1.2.1.2.2
Description A list of interface entries. The number of entries is given by
the value of ifNumber.
ifEntry
OID 1.3.6.1.2.1.2.2.1
Description An interface entry containing objects at the subnetwork layer
and below, for a particular interface.
Index ifIndex
ifIndex
OID 1.3.6.1.2.1.2.2.1.1
Description A unique value for each interface.
Note: The values range between 1 and the value of ifNumber. The value for each
interface must remain constant at least from one re-initialization of the entity's network
management system to the next re-initialization.
For example, the number of entries inside the Core Switch 2/64 switch: 1 to 3 for FCIP,
otherwise the value is 1 or 2
ifDescr
OID 1.3.6.1.2.1.2.2.1.2
Description A textual string containing information about the interface.
Note: For example, Core Switch 2/64: fei0, lo0, fc0. Also, eth0 for Fabric OS v4.x.
ifType
OID 1.3.6.1.2.1.2.2.1.3
Description The type of interface, designated by the physical/link
protocol(s) immediately below the network layer in the
protocol stack.
ifMtu
OID 1.3.6.1.2.1.2.2.1.4
Description The size of the largest datagram that can be sent/received on
the interface, specified in octets.
Note: For interfaces that are used to transmit network datagrams, the value is the size
of the largest network datagram that can be sent on the interface (these values are
different for Fabric OS v4.x).
ifSpeed
OID 1.3.6.1.2.1.2.2.1.5
Description An estimate (in bits per second) of the interface's current
bandwidth.
Note: For interfaces that do not vary in bandwidth or interfaces for which no accurate
estimation can be made, this object should contain the nominal bandwidth. For Fabric
OS v4.x, 2 GB returns.
lo0 returns 0.
ifPhysAddress
OID 1.3.6.1.2.1.2.2.1.6
Description The interface's address at the protocol layer immediately
below the network layer in the protocol stack.
Note: For interfaces that do not have such an address (for example, a serial line), this
object should contain an octet string of zero length.
ifAdminStatus
OID 1.3.6.1.2.1.2.2.1.7
Description The desired state of the interface.
Note: The 3 (testing) state indicates that no operational packets can be passed. This
object is read-only in Fabric OS v4.x.
ifOperStatus
OID 1.3.6.1.2.1.2.2.1.8
Description The current operational state of the interface.
Note: The 3 (testing) state indicates that no operational packets can be passed.
ifLastChange
OID 1.3.6.1.2.1.2.2.1.9
Description The value of sysUpTime at the time the interface entered its
current operational state. If the current state was entered prior
to the last re-initialization of the local network management
subsystem, then this object contains a zero value.
ifInOctets
OID 1.3.6.1.2.1.2.2.1.10
ifInUcastPkts
OID 1.3.6.1.2.1.2.2.1.11
Description The number of subnetwork-unicast packets delivered to a
higher-layer protocol.
ifInNUcastPkts
OID 1.3.6.1.2.1.2.2.1.12
Description The number of non-unicast packets (for example,
subnetwork- broadcast or subnetwork-multicast) delivered to
a higher-layer protocol.
ifInDiscards
OID 1.3.6.1.2.1.2.2.1.13
Description The number of inbound packets which were chosen to be
discarded even though no errors had been detected to prevent
their being deliverable to a higher-layer protocol.
Note: One possible reason for discarding such a packet could be to free up buffer
space.
ifInErrors
OID 1.3.6.1.2.1.2.2.1.14
Description The number of inbound packets that contained errors, which
thereby prevented them from being deliverable to a
higher-layer protocol.
ifInUnknownProtos
OID 1.3.6.1.2.1.2.2.1.15
ifOutOctets
OID 1.3.6.1.2.1.2.2.1.16
Description The total number of octets transmitted out of the interface,
including framing characters.
ifOutUcastPkts
OID 1.3.6.1.2.1.2.2.1.17
Description The total number of packets that were requested, by
higher-level protocols, to be transmitted to a
subnetwork-unicast address, including those that were
discarded or not sent.
ifOutNUcastPkts
OID 1.3.6.1.2.1.2.2.1.18
Description The total number of packets that were requested, by
higher-level protocols, to be transmitted to a non-unicast
address (for example, a subnetwork-broadcast or
subnetwork-multicast), including those that were discarded or
not sent.
ifOutDiscards
OID 1.3.6.1.2.1.2.2.1.19
Description The number of outbound packets that were chosen to be
discarded even though no errors had been detected to prevent
their being transmitted. One possible reason for discarding
such a packet could be to free up buffer space.
ifOutErrors
OID 1.3.6.1.2.1.2.2.1.20
Description The number of outbound packets that could not be transmitted
because of errors.
ifOutQLen
OID 1.3.6.1.2.1.2.2.1.21
Description The length of the output packet queue (in packets).
ifSpecific
OID 1.3.6.1.2.1.2.2.1.22
Description A reference to MIB definitions specific to the particular media
being used to realize the interface.
For example, if the interface is realized by an ethernet, then
the value of this object refers to a document defining objects
specific to ethernet. If this information is not present, its value
should be set to the Object Identifier 0 0, which is a
syntactically valid object identifier, and any conferment
implementation of ASN.1 and BER must be able to generate
and recognize this value.
OID 1.3.6.1.2.1.3.1
Description The Address Translation tables contain the NetworkAddress
to physical address equivalences. Some interfaces do not use
translation tables for determining address equivalences (for
example, DDN-X.25 has an algorithmic method); if all
interfaces are of this type, then the Address Translation table
is empty, and therefore has zero entries.
atEntry
OID 1.3.6.1.2.1.3.1.1
Description Each entry contains one NetworkAddress to physical address
equivalence.
Index atIfIndex, atNetAddress
atIfIndex
OID 1.3.6.1.2.1.3.1.1.1
Description The interface on which this entry's equivalence is effective.
The interface identified by a particular value of this index is
the same interface as identified by the same value of ifIndex.
atPhysAddress
OID 1.3.6.1.2.1.3.1.1.2
Description The media-dependent physical address.
Note: Setting this object to a null string (one of zero length) has the effect of
invalidating the corresponding entry in the atTable object. That is, it effectively
disassociates the interface identified with said entry from the mapping identified with
said entry. It is an implementation-specific matter as to whether the agent removes an
invalidated entry from the table. Accordingly, management stations must be prepared
to receive tabular information from agents that corresponds to entries not currently in
use. Proper interpretation of such entries requires examination of the relevant
atPhysAddress object.
atNetAddress
OID 1.3.6.1.2.1.3.1.1.3
Description The NetworkAddress (for example, the IP address)
corresponding to the media-dependent physical address.
IP Group
Implementation of the IP group is mandatory for all systems.
ipForwarding
OID 1.3.6.1.2.1.4.1
Description The indication of whether this entity is acting as an IP gateway
in respect to the forwarding of datagrams received by, but not
addressed to, this entity. IP gateways forward datagrams. IP
hosts do not (except those source-routed via the host).
Note: For some managed nodes, this object may take on only a subset of the values
possible. Accordingly, it is appropriate for an agent to return a badValue response if
a management station attempts to change this object to an inappropriate value.
ipDefaultTTL
OID 1.3.6.1.2.1.4.2
Description The default value inserted into the Time-To-Live field of the
IP header of datagrams originated at this entity, whenever a
TTL value is not supplied by the transport layer protocol.
ipInReceives
OID 1.3.6.1.2.1.4.3
Description The total number of input datagrams received from interfaces,
including those received in error.
ipInHdrErrors
OID 1.3.6.1.2.1.4.4
Description The number of input datagrams discarded due to errors in
their IP headers, including bad checksums, version number
mismatch, other format errors, time-to-live exceeded, errors
discovered in processing their IP options, and so on.
ipInAddrErrors
OID 1.3.6.1.2.1.4.5
Description The number of input datagrams discarded because the IP
address in their IP header's destination field was not a valid
address to be received at this entity. This count includes
invalid addresses (for example, 0.0.0.0) and addresses of
unsupported Classes (for example, Class E). For entities
which are not IP Gateways and therefore do not forward
datagrams, this counter includes datagrams discarded because
the destination address was not a local address.
ipForwDatagrams
OID 1.3.6.1.2.1.4.6
Description The number of input datagrams for which this entity was not
their final IP destination, as a result of which an attempt was
made to find a route to forward them to that final destination.
In entities which do not act as IP Gateways, this counter will
include only those packets which were Source-Routed via this
entity, and the Source-Route option processing was
successful.
ipInUnknownProtos
OID 1.3.6.1.2.1.4.7
Description The number of locally-addressed datagrams received
successfully but discarded because of an unknown or
unsupported protocol.
ipInDiscards
OID 1.3.6.1.2.1.4.8
Description The number of input IP datagrams for which no problems
were encountered to prevent their continued processing, but
which were discarded (for example, for lack of buffer space).
Note: This counter does not include any datagrams discarded while awaiting
re-assembly.
ipInDelivers
OID 1.3.6.1.2.1.4.9
Description The total number of input datagrams successfully delivered to
IP user-protocols (including ICMP).
ipOutRequests
OID 1.3.6.1.2.1.4.10
Description The total number of IP datagrams which local IP
user-protocols (including ICMP) supplied to IP in requests for
transmission. Note that this counter does not include any
datagrams counted in ipForwDatagrams.
ipOutDiscards
OID 1.3.6.1.2.1.4.11
Description The number of output IP datagrams for which no problem was
encountered to prevent their transmission to their destination,
but which were discarded (for example, for lack of buffer
space).
Note: This counter would include datagrams counted in ipForwDatagrams if any such
packets met this (discretionary) discard criterion.
ipOutNoRoutes
OID 1.3.6.1.2.1.4.12
Description The number of IP datagrams discarded because no route could
be found to transmit them to their destination.
Note: This counter includes any packets counted in ipForwDatagrams which meet this
no-route criterion. Note that this includes any datagarms which a host cannot route
because all of its default gateways are down.
ipReasmTimeout
OID 1.3.6.1.2.1.4.13
Description The maximum number of seconds which received fragments
are held while they are awaiting reassembly at this entity.
ipReasmReqds
OID 1.3.6.1.2.1.4.14
Description The number of IP fragments received which needed to be
reassembled at this entity.
ipReasmOKs
OID 1.3.6.1.2.1.4.15
Description The number of IP datagrams successfully re-assembled.
ipReasmFails
OID 1.3.6.1.2.1.4.16
Description The number of failures detected by the IP re-assembly
algorithm (for whatever reason, timed out, errors, and so on).
Note: This is not necessarily a count of discarded IP fragments since some algorithms
(notably the algorithm in RFC 815) can lose track of the number of fragments by
combining them as they are received.
ipFragOKs
OID 1.3.6.1.2.1.4.17
Description The number of IP datagrams that have been successfully
fragmented at this entity.
ipFragFails
OID 1.3.6.1.2.1.4.18
Description The number of IP datagrams that have been discarded because
they needed to be fragmented at this entity but could not be
(for example, because their Don't Fragment flag was set).
ipFragCreates
OID 1.3.6.1.2.1.4.19
Description The number of IP datagram fragments that have been
generated as a result of fragmentation at this entity.
IP Address Table
The IP address table contains this entity’s IP addressing information.
ipAddrTable
OID 1.3.6.1.2.1.4.20
Description The table of addressing information relevant to this entity's IP
addresses.
ipAddrEntry
OID 1.3.6.1.2.1.4.20.1
Description The addressing information for one of this entity's IP
addresses.
Index ipAdEntAddr
ipAdEntAdd
r
OID 1.3.6.1.2.1.4.20.1.1
Description The IP address to which this entry's addressing information
pertains.
ipAdEntIfIndex
OID 1.3.6.1.2.1.4.20.1.2
ipAdEntNetMask
OID 1.3.6.1.2.1.4.20.1.3
Description The subnet mask associated with the IP address of this entry.
The value of the mask is an IP address with all the network
bits set to 1 and all the hosts bits set to 0.
ipAdEntBcastAddr
OID 1.3.6.1.2.1.4.20.1.4
Description The value of the least-significant bit in the IP broadcast
address used for sending datagrams on the (logical) interface
associated with the IP address of this entry. For example,
when the Internet standard all-ones broadcast address is used,
the value will be 1. This value applies to both the subnet and
network broadcasts addresses used by the entity on this
(logical) interface.
ipAdEntReasmMaxSize
OID 1.3.6.1.2.1.4.20.1.5
Description The size of the largest IP datagram which this entity can
re-assemble from incoming IP fragmented datagrams received
on this interface.
IP Routing Table
The IP routing table contains an entry for each route presently known to this
entity.
ipRouteTable
OID 1.3.6.1.2.1.4.21
Description This entity’s IP Routing table.
ipRouteEntry
OID 1.3.6.1.2.1.4.21.1
Description A route to a particular destination.
Index ipRouteDest
ipRouteDest
OID 1.3.6.1.2.1.4.21.1.1
Description The destination IP address of this route.
Note: An entry with a value of 0.0.0.0 is considered a default route. Multiple routes to
a single destination can appear in the table, but access to such multiple entries is
dependent on the table-access mechanisms defined by the network management
protocol in use.
ipRouteIfIndex
OID 1.3.6.1.2.1.4.21.1.2
Description The index value which uniquely identifies the local interface
through which the next hop of this route should be reached.
Note: The interface identified by a particular value of this index is the same interface
as identified by the same value of ifIndex.
ipRouteMetric1
OID 1.3.6.1.2.1.4.21.1.3
Description The primary routing metric for this route.
Note: The semantics of this metric are determined by the routing-protocol specified in
the route's ipRouteProto value. If this metric is not used, its value should be set to -1.
ipRouteMetric2
OID 1.3.6.1.2.1.4.21.1.4
Description An alternate routing metric for this route.
Note: The semantics of this metric are determined by the routing-protocol specified in
the route's ipRouteProto value. If this metric is not used, its value should be set to -1.
ipRouteMetric3
3
OID 1.3.6.1.2.1.4.21.1.5
Description An alternate routing metric for this route.
Note: The semantics of this metric are determined by the routing-protocol specified in
the route's ipRouteProto value. If this metric is not used, its value should be set to -1.
ipRouteMetric4
4
OID 1.3.6.1.2.1.4.21.1.6
Description An alternate routing metric for this route.
Note: The semantics of this metric are determined by the routing-protocol specified in
the route's ipRouteProto value. If this metric is not used, its value should be set to -1.
ipRouteNextHop
OID 1.3.6.1.2.1.4.21.1.7
Description The IP address of the next hop of this route. (In the case of a
route bound to an interface which is realized via a broadcast
media, the value of this field is the agent’s IP address on that
interface.)
ipRouteType
e
OID 1.3.6.1.2.1.4.21.1.8
Description The type of route. Valid values are:
other (1): None of the following
invalid (2): An invalidated route—route to directly
direct (3): Connected (sub-)network—route to a
non-local
indirect (4): Host/network/sub-network
Setting this object to 2 (invalid) has the effect of invalidating
the corresponding entry in the ipRouteTable object. That is, it
effectively dissasociates the destination identified with said
entry from the route identified with said entry. It is an
implementation-specific matter as to whether the agent
removes an invalidated entry from the table. Accordingly,
management stations must be prepared to receive tabular
information from agents that corresponds to entries not
currently in use. Proper interpretation of such entries requires
examination of the relevant ipRouteType object.
Note: The values direct (3) and indirect (4) refer to the notion of direct and indirect
routing in the IP architecture.
ipRouteProto
OID 1.3.6.1.2.1.4.21.1.9
Description The routing mechanism via which this route was learned.
Note: Inclusion of values for gateway routing protocols is not intended to imply that
hosts should support those protocols.
ipRouteAge
OID 1.3.6.1.2.1.4.21.1.10
Description The number of seconds since this route was last updated or
otherwise determined to be correct.
Note: Older semantics cannot be implied except through knowledge of the routing
protocol by which the route was learned.
ipRouteMask
OID 1.3.6.1.2.1.4.21.1.11
Description The mask to be logical-ANDed with the destination address
before being compared to the value in the ipRouteDest field.
For those systems that do not support arbitrary subnet masks,
an agent constructs the value of the ipRouteMask by
determining whether the value of the correspondent
ipRouteDest field belong to a class-A, B, or C network, and
then using one of the following:
mask network
255.0.0.0 class-A
255.255.0.0 class-B
255.255.255.0 class-C
If the value of the ipRouteDest is 0.0.0.0 (default route), then
the mask value is also 0.0.0.0.
ipRouteMetric5
OID 1.3.6.1.2.1.4.21.1.12
Description An alternate routing metric for this route.
Note: The semantics of this metric are determined by the routing-protocol specified in
the route's ipRouteProto value. If this metric is not used, its value should be set to -1.
ipRouteInfo
OID 1.3.6.1.2.1.4.21.1.13
OID 1.3.6.1.2.1.4.22
Description The IP Address Translation table used for mapping from IP
addresses to physical addresses.
ipNetToMediaEntry
OID 1.3.6.1.2.1.4.22.1
Description Each entry contains one IpAddress to physical address
equivalence.
Index ipNetToMediaIfIndex, ipNetToMediaNetAddress
ipNetToMediaIfIndex
OID 1.3.6.1.2.1.4.22.1.1
Description The interface on which this entry's equivalence is effective.
Note: The interface identified by a particular value of this index is the same interface
as identified by the same value of ifIndex.
ipNetToMediaPhysAddress
OID 1.3.6.1.2.1.4.22.1.2
Description The media-dependent physical address.
ipNetToMediaNetAddress
OID 1.3.6.1.2.1.4.22.1.3
Description The IpAddress corresponding to the media-dependent
physical address.
ipNetToMediaType
OID 1.3.6.1.2.1.4.22.1.4
Description The type of mapping.
Note: Setting this object to invalid (2), invalidates the corresponding entry in the
ipNetToMediaTable. That is, it effectively dissasociates the interface identified with said
entry from the mapping identified with said entry. It is an implementation-specific
matter as to whether the agent removes an invalidated entry from the table.
Accordingly, management stations must be prepared to receive tabular information
from agents that corresponds to entries not currently in use. Proper interpretation of such
entries requires examination of the relevant ipNetToMediaType object.
Additional IP Objects
ipRoutingDiscards
OID 1.3.6.1.2.1.4.23
Description The number of routing entries that were chosen to be
discarded even though they are valid. One possible reason for
discarding such an entry could be to free-up buffer space for
other routing entries.
ICMP Group
Implementation of the ICMP group is mandatory for all systems.
icmpInMsgs
OID 1.3.6.1.2.1.5.1
Description The total number of ICMP messages which the entity
received.
icmpInErrors
OID 1.3.6.1.2.1.5.2
Description The number of ICMP messages which the entity received but
determined as having ICMP-specific errors (bad ICMP
checksums, bad length, and so on).
icmpInDestUnreachs
OID 1.3.6.1.2.1.5.3
Description The number of ICMP Destination Unreachable messages
received.
icmpInTimeExcds
OID 1.3.6.1.2.1.5.4
Description The number of ICMP Time Exceeded messages received.
icmpInParmProbs
OID 1.3.6.1.2.1.5.5
Description The number of ICMP Parameter Problem messages received.
icmpInSrcQuenchs
OID 1.3.6.1.2.1.5.6
icmpInRedirects
OID 1.3.6.1.2.1.5.7
Description The number of ICMP Redirect messages received.
icmpInEchos
OID 1.3.6.1.2.1.5.8
Description The number of ICMP Echo (request) messages received.
icmpInEchoReps
OID 1.3.6.1.2.1.5.9
Description The number of ICMP Echo Reply messages received.
icmpInTimestamps
OID 1.3.6.1.2.1.5.10
Description The number of ICMP Timestamp (request) messages
received.
icmpInTimestampReps
OID 1.3.6.1.2.1.5.11
Description The number of ICMP Timestamp Reply messages received.
icmpInAddrMasks
OID 1.3.6.1.2.1.5.12
Description The number of ICMP Address Mask Request messages
received.
icmpInAddrMaskReps
OID 1.3.6.1.2.1.5.13
Description The number of ICMP Address Mask Reply messages
received.
icmpOutMsgs
OID 1.3.6.1.2.1.5.14
Description The total number of ICMP messages that this entity attempted
to send.
icmpOutErrors
OID 1.3.6.1.2.1.5.15
Description The number of ICMP messages which this entity did not send
due to problems discovered within ICMP such as a lack of
buffers. This value should not include errors discovered
outside the ICMP layer such as the inability of IP to route the
resultant datagram. In some implementations there may be no
types of error which contribute to this counter's value.
icmpOutDestUnreachs
OID 1.3.6.1.2.1.5.16
Description The number of ICMP Destination Unreachable messages sent.
icmpOutTimeExcds
OID 1.3.6.1.2.1.5.17
Description The number of ICMP Time Exceeded messages sent.
icmpOutParmProbs
OID 1.3.6.1.2.1.5.18
Description The number of ICMP Parameter Problem messages sent.
icmpOutSrcQuenchs
OID 1.3.6.1.2.1.5.19
Description The number of ICMP Source Quench messages sent.
icmpOutRedirects
OID 1.3.6.1.2.1.5.20
Description The number of ICMP Redirect messages sent. For a host, this
object will always be zero, since hosts do not send redirects.
icmpOutEchos
OID 1.3.6.1.2.1.5.21
Description The number of ICMP Echo (request) messages sent.
icmpOutEchoReps
OID 1.3.6.1.2.1.5.22
Description The number of ICMP Echo Reply messages sent.
icmpOutTimestamps
OID 1.3.6.1.2.1.5.23
Description The number of ICMP Timestamp (request) messages sent.
icmpOutTimestampReps
OID 1.3.6.1.2.1.5.24
Description The number of ICMP Timestamp Reply messages sent.
icmpOutAddrMasks
OID 1.3.6.1.2.1.5.25
Description The number of ICMP Address Mask Request messages sent.
icmpOutAddrMaskReps
OID 1.3.6.1.2.1.5.26
Description The number of ICMP Address Mask Reply messages sent.
TCP Group
Implementation of the TCP group is mandatory for all systems that implement the
TCP.
Note: Instances of object types that represent information about a particular TCP
connection are transient; they persist only as long as the connection in question.
tcpRtoAlgorithm
OID 1.3.6.1.2.1.6.1
Description The algorithm used to determine the time-out value used for
retransmitting unacknowledged octets.
tcpRtoMin
OID 1.3.6.1.2.1.6.2
Description The minimum value permitted by a TCP implementation for
the retransmission time-out, measured in milliseconds.
Note: More refined semantics for objects of this type depend upon the algorithm used
to determine the retransmission time-out. In particular, when the time-out algorithm is 3
(rsre), an object of this type has the semantics of the LBOUND quantity described in
RFC 793.
tcpRtoMax
OID 1.3.6.1.2.1.6.3
Description The maximum value permitted by a TCP implementation for
the retransmission time-out, measured in milliseconds.
Note: More refined semantics for objects of this type depend upon the algorithm used
to determine the retransmission time-out. In particular, when the time-out algorithm is 3
(rsre), an object of this type has the semantics of the UBOUND quantity described in
RFC 793.
tcpMaxConn
OID 1.3.6.1.2.1.6.4
Description The limit on the total number of TCP connections the entity
can support. In entities where the maximum number of
connections is dynamic, this object should contain the value
-1.
tcpActiveOpens
OID 1.3.6.1.2.1.6.5
Description The number of times TCP connections have made a direct
transition to the SYN-SENT state from the CLOSED state.
tcpPassiveOpens
OID 1.3.6.1.2.1.6.6
Description The number of times TCP connections have made a direct
transition to the SYN-RCVD state from the LISTEN state.
tcpAttemptFails
OID 1.3.6.1.2.1.6.7
Description The number of times TCP connections have made a direct
transition to the CLOSED state from either the SYN-SENT
state or the SYN-RCVD state, plus the number of times TCP
connections have made a direct transition to the LISTEN state
from the SYN-RCVD state.
tcpEstabResets
OID 1.3.6.1.2.1.6.8
Description The number of times TCP connections have made a direct
transition to the CLOSED state from either the
ESTABLISHED state or the CLOSE-WAIT state.
tcpCurrEstab
OID 1.3.6.1.2.1.6.9
Description The number of TCP connections for which the current state is
either ESTABLISHED or CLOSE- WAIT.
tcpInSegs
OID 1.3.6.1.2.1.6.10
Description The total number of segments received, including those
received in error. This count includes segments received on
currently established connections.
tcpOutSegs
OID 1.3.6.1.2.1.6.11
Description The total number of segments sent, including those on current
connections but excluding those containing only retransmitted
octets.
tcpRetransSegs
OID 1.3.6.1.2.1.6.12
Description The total number of segments retransmitted—that is, the
number of TCP segments transmitted containing one or more
previously transmitted octets.
OID 1.3.6.1.2.1.6.13
Description A table containing TCP connection-specific information.
tcpConnEntry
OID 1.3.6.1.2.1.6.13.1
tcpConnState
OID 1.3.6.1.2.1.6.13.1.1
Description The state of this TCP connection. Possible values are:
closed (1)
listen (2)
synSent (3)
synReceived (4)
established (5)
finWait1 (6)
finWait2 (7)
closeWait (8)
lastAck (9)
closing (10)
timeWait (11)
deleteTCB (12)
Note: The only value which may be set by a management station is deleteTCB (12).
Accordingly, it is appropriate for an agent to return a badValue response if a
management station attempts to set this object to any other value.
If a management station sets this object to the value delete12 (TCB), then this has the
effect of deleting the TCB (as defined in RFC 793) of the corresponding connection on
the managed node, resulting in immediate termination of the connection.
As an implementation-specific option, a RST segment may be sent from the managed
node to the other TCP endpoint (note however that RST segments are not sent reliably).
tcpConnLocalAddress
OID 1.3.6.1.2.1.6.13.1.2
Description The local IP address for this TCP connection. In the case of a
connection in the listen state which is willing to accept
connections for any IP interface associated with the node, the
value 0.0.0.0 is used.
tcpConnLocalPort
OID 1.3.6.1.2.1.6.13.1.3
Description The local port number for this TCP connection.
tcpConnRemAddress
OID 1.3.6.1.2.1.6.13.1.4
Description The remote IP address for this TCP connection.
tcpConnRemPort
OID 1.3.6.1.2.1.6.13.1.5
Description The remote port number for this TCP connection.
OID 1.3.6.1.2.1.6.14
Description The total number of segments received in error (for example,
bad TCP checksums).
tcpOutRsts
OID 1.3.6.1.2.1.6.15
Description The number of TCP segments sent containing the RST flag.
UDP Group
Implementation of the UDP group is mandatory for all systems which implement
the UDP.
udpInDatagrams
OID 1.3.6.1.2.1.7.1
Description The total number of UDP datagrams delivered to UDP users.
udpNoPorts
OID 1.3.6.1.2.1.7.2
Description The total number of received UDP datagrams for which there
was no application at the destination port.
udpInErrors
OID 1.3.6.1.2.1.7.3
Description The number of received UDP datagrams that could not be
delivered for reasons other than the lack of an application at
the destination port.
udpOutDatagrams
OID 1.3.6.1.2.1.7.4
Description The total number of UDP datagrams sent from this entity.
OID 1.3.6.1.2.1.7.5
Description A table containing UDP listener information.
udpEntry
OID 1.3.6.1.2.1.7.5.1
Description Information about a particular current UDP listener.
Index udpLocalAddress, udpLocalPort
udpLocalAddress
OID 1.3.6.1.2.1.7.5.1.1
Description The local IP address for this UDP listener. In the case of a
UDP listener which is willing to accept datagrams for any IP
interface associated with the node, the value 0.0.0.0 is used.
udpLocalPort
OID 1.3.6.1.2.1.7.5.1.2
Description The local port number for this UDP listener.
EGP Group
Implementation of the EGP group is mandatory for all systems which implement
the EGP.
Note: HP does not support the EGP Group—this section is not applicable
egpInMsg
s
OID 1.3.6.1.2.1.8.1
Description The number of EGP messages received without error.
egpInErrors
OID 1.3.6.1.2.1.8.2
Description The number of EGP messages received that proved to be in
error.
egpOutMsgs
OID 1.3.6.1.2.1.8.3
Description The total number of locally generated EGP messages.
egpOutErrors
OID 1.3.6.1.2.1.8.4
Description The number of locally generated EGP messages not sent due
to resource limitations within an EGP entity.
OID 1.3.6.1.2.1.8.5
Description The EGP neighbor table.
egpNeighEntry
OID 1.3.6.1.2.1.8.5.1
Description Information about this entity's relationship with a particular
EGP neighbor.
Index egpNeighAddr
egpNeighState
OID 1.3.6.1.2.1.8.5.1.1
Description The EGP state of the local system with respect to this entry's
EGP neighbor. Each EGP state is represented by a value that
is one greater than the numerical value associated with said
state in RFC 904.
egpNeighAddr
OID 1.3.6.1.2.1.8.5.1.2
Description The IP address of this entry's EGP neighbor.
egpNeighAs
OID 1.3.6.1.2.1.8.5.1.3
Description The autonomous system of this EGP peer. Zero should be
specified if the autonomous system number of the neighbor is
not yet known.
egpNeighInMsgs
OID 1.3.6.1.2.1.8.5.1.4
egpNeighInErrs
OID 1.3.6.1.2.1.8.5.1.5
Description The number of EGP messages received from this EGP peer
that proved to be in error (for example, bad EGP checksum).
egpNeighOutMsgs
OID 1.3.6.1.2.1.8.5.1.6
Description The number of locally generated EGP messages to this EGP
peer.
egpNeighOutErrs
OID 1.3.6.1.2.1.8.5.1.7
Description The number of locally generated EGP messages not sent to
this EGP peer due to resource limitations within an EGP
entity.
egpNeighInErrMsgs
OID 1.3.6.1.2.1.8.5.1.8
Description The number of EGP-defined error messages received from
this EGP peer.
egpNeighOutErrMsgs
OID 1.3.6.1.2.1.8.5.1.9
Description The number of EGP-defined error messages sent to this EGP
peer.
egpNeighStateUps
OID 1.3.6.1.2.1.8.5.1.10
Description The number of EGP state transitions to the UP state with this
EGP peer.
egpNeighStateDowns
OID 1.3.6.1.2.1.8.5.1.11
Description The number of EGP state transitions from the UP state to any
other state with this EGP peer.
egpNeighIntervalHello
OID 1.3.6.1.2.1.8.5.1.12
Description The interval between EGP Hello command retransmissions
(in hundredths of a second). This represents the t1 timer as
defined in RFC 904.
egpNeighIntervalPoll
OID 1.3.6.1.2.1.8.5.1.13
Description The interval between EGP poll command retransmissions (in
hundredths of a second). This represents the t3 timer as
defined in RFC 904.
egpNeighMode
OID 1.3.6.1.2.1.8.5.1.14
Description The polling mode of this EGP entity, either active (1) or
passive (2).
egpNeighEventTrigger
OID 1.3.6.1.2.1.8.5.1.15
Note: When read, this variable always returns the most recent value that
egpNeighEventTrigger was set to. If it has not been set since the last initialization of the
network management subsystem on the node, it returns a value of stop.
When set, this variable causes a Start or Stop event on the specified neighbor, as
specified in RFC 904. Briefly, a Start event causes an Idle peer to begin neighbor
acquisition and a non-Idle peer to re-initiate neighbor acquisition. A Stop event causes
a non-Idle peer to return to the Idle state until a Start event occurs, either via
egpNeighEventTrigger or otherwise.
OID 1.3.6.1.2.1.8.6
Description The autonomous system number of this EGP entity.
Transmission Group
Based on the transmission media underlying each interface on a system, the
corresponding portion of the Transmission group is mandatory for that system.
When Internet-standard definitions for managing transmission media are defined,
the transmission group is used to provide a prefix for the names of those objects.
Typically, such definitions reside in the experimental portion of the MIB until they
are proven, then as a part of the Internet standardization process, the definitions
are accordingly elevated and a new object identifier, under the transmission group
is defined. By convention, the name assigned is:
type Object Identifier ::= { transmission number }
where type is the symbolic value used for the media in the ifType column of the
ifTable object, and number is the actual integer value corresponding to the
symbol.
SNMP Group
Implementation of the SNMP group is mandatory for all systems which support
an SNMP protocol entity. Some of the objects defined below will be zero-valued
in those SNMP implementations that are optimized to support only those
functions specific to either a management agent or a management station. All of
the objects below refer to an SNMP entity, and there may be several SNMP
entities residing on a managed node (for example, if the node is acting as a
management station).
snmpInPkts
OID 1.3.6.1.2.1.11.1
Description The total number of Messages delivered to the SNMP entity
from the transport service.
snmpOutPkts
OID 1.3.6.1.2.1.11.2
Description The total number of SNMP Messages which were passed
from the SNMP protocol entity to the transport service.
snmpInBadVersions
OID 1.3.6.1.2.1.11.3
Description The total number of SNMP Messages which were delivered to
the SNMP protocol entity and were for an unsupported SNMP
version.
snmpInBadCommunityNames
OID 1.3.6.1.2.1.11.4
Description The total number of SNMP Messages delivered to the SNMP
protocol entity which used a SNMP community name not
known to said entity.
snmpInBadCommunityUses
OID 1.3.6.1.2.1.11.5
snmpInASNParseErrs
OID 1.3.6.1.2.1.11.6
Description The total number of ASN.1 or BER errors encountered by the
SNMP protocol entity when decoding received SNMP
Messages.
snmpInTooBigs
OID 1.3.6.1.2.1.11.8
Description The total number of SNMP PDUs which were delivered to the
SNMP protocol entity and for which the value of the
error-status field is tooBig.
snmpInNoSuchNames
OID 1.3.6.1.2.1.11.9
Description The total number of SNMP PDUs which were delivered to the
SNMP protocol entity and for which the value of the
error-status field is noSuchName.
snmpInBadValues
OID 1.3.6.1.2.1.11.10
Description The total number of SNMP PDUs which were delivered to the
SNMP protocol entity and for which the value of the
error-status field is badValue.
snmpInReadOnlys
OID 1.3.6.1.2.1.11.11
Description The total number valid SNMP PDUs which were delivered to
the SNMP protocol entity and for which the value of the
error-status field is readOnly.
Note: It is a protocol error to generate an SNMP PDU which contains the value
“readOnly” in the error-status field, as such this object is provided as a means of
detecting incorrect implementations of the SNMP.
snmpInGenErrs
OID 1.3.6.1.2.1.11.12
Description The total number of SNMP PDUs which were delivered to the
SNMP protocol entity and for which the value of the
error-status field is genErr.
snmpInTotalReqVars
OID 1.3.6.1.2.1.11.13
Description The total number of MIB objects which have been retrieved
successfully by the SNMP protocol entity as the result of
receiving valid SNMP Get-Request and Get-Next PDUs.
snmpInTotalSetVars
OID 1.3.6.1.2.1.11.14
Description The total number of MIB objects which have been altered
successfully by the SNMP protocol entity as the result of
receiving valid SNMP Set-Request PDUs.
snmpInGetRequests
OID 1.3.6.1.2.1.11.15
Status Mandatory
Description The total number of SNMP Get-Request PDUs which have
been accepted and processed by the SNMP protocol entity.
snmpInGetNexts
OID 1.3.6.1.2.1.11.16
Description The total number of SNMP Get-Next PDUs which have been
accepted and processed by the SNMP protocol entity.
snmpInSetRequests
OID 1.3.6.1.2.1.11.17
Description The total number of SNMP Set-Request PDUs which have
been accepted and processed by the SNMP protocol entity.
snmpInGetResponses
OID 1.3.6.1.2.1.11.18
Description The total number of SNMP Get-Response PDUs which have
been accepted and processed by the SNMP protocol entity.
snmpInTraps
OID 1.3.6.1.2.1.11.19
Description The total number of SNMP Trap PDUs which have been
accepted and processed by the SNMP protocol entity.
snmpOutTooBigs
OID 1.3.6.1.2.1.11.20
Description The total number of SNMP PDUs which were generated by
the SNMP protocol entity and for which the value of the
error-status field is too large.
snmpOutNoSuchNames
OID 1.3.6.1.2.1.11.21
D
snmpOutBadValues
OID 1.3.6.1.2.1.11.22
Description The total number of SNMP PDUs which were generated by
the SNMP protocol entity and for which the value of the
error-status field is badValue.
snmpOutGenErrs
OID 1.3.6.1.2.1.11.24
Description The total number of SNMP PDUs which were generated by
the SNMP protocol entity and for which the value of the
error-status field is genErr.
snmpOutGetRequests
OID 1.3.6.1.2.1.11.25
Description The total number of SNMP Get-Request PDUs which have
been generated by the SNMP protocol entity.
snmpOutGetNexts
OID 1.3.6.1.2.1.11.26
Description The total number of SNMP Get-Next PDUs which have been
generated by the SNMP protocol entity.
snmpOutSetRequests
OID 1.3.6.1.2.1.11.27
Description The total number of SNMP Set-Request PDUs which have
been generated by the SNMP protocol entity.
snmpOutGetResponses
OID 1.3.6.1.2.1.11.28
snmpOutTraps
OID 1.3.6.1.2.1.11.29
Description The total number of SNMP Trap PDUs which have been
generated by the SNMP protocol entity.
snmpEnableAuthenTraps
OID 1.3.6.1.2.1.11.30
Description Indicates whether the SNMP agent process is permitted to
generate authentication-failure traps. The value of this object
overrides any configuration information; as such, it provides a
means whereby all authentication-failure traps may be
disabled. Possible values are:
enabled (1)
disabled (2)
Note: This object is stored in non-volatile memory so that it remains constant between
re-initializations of the switch.
Overview
HP supports two versions of the FE MIB:
■ FIBRE-CHANNEL-FE-MIB (RFC2837) in the mib-2 branch.
■ FCFABRIC-ELEMENT-MIB in the experimental branch.
The version of the FE MIB supported depends on the version of the Fabric OS.
Table 3 lists which FE MIB is supported in which Fabric OS version.
Table 3: FE MIBs and Supported Fabric OS Versions
MIB 4.1.x 4.0.x 3.1.x 3.0.x 2.6.x
FIBRE-CHANNEL-FE-MIB Yes Yes Yes Yes No
(mib-2 branch)
FCFABRIC-ELEMENT-MIB No No No Yes Yes
(experimental branch)
Note: HP does not support the settable “Write” function for any of the Fibre Channel
FE MIB objects except fcFxPortPhyAdminStatus.
FIBRE-CHANNEL-FE-MIB Organization
Figure 5 through Figure 8 depict the organization and structure of
FIBRE-CHANNEL-FE-MIB:
- iso (1)
- org (3)
- dod (6)
- internet (1)
- mgmt (2)
- mib-2 (1)
- fcFeMIB (75)
- fcFeMIBObjects (1)
- fcFeConfig (1)
- fcFeStatus (2)
- fcFeError (3)
- fcFeAccounting (4)
- fcFeCapabilities (5)
- fcFeMIBConformance (2)
- fcFeMIBCompliances (1)
- fcFeMIBGroups (2)
Figure 5: FIBRE-CHANNEL-FE-MIB Overall Tree Structure
- fcFeConfig (1.3.6.1.2.1.75.1.1)
- fcFeFabricName (1)
- fcFeElementName (2)
- fcFeModuleCapacity (3)
- fcFeModuleTable (4)
- fcFeModuleEntry (1)
- fcFeModuleIndex (1)
- fcFeModuleDescr (2)
- fcFeModuleObjectID (3)
- fcFeModuleOperStatus (4)
- fcFeModuleLastChange (5)
- fcFeModuleFxPortCapacity (6)
- fcFeModuleName (7)
- fcFxPortTable (5)
- fcFxPortEntry (1)
- fcFxPortIndex (1)
- fcFxPortName (2)
- fcFxPortFcphVersionHigh (3)
- fcFxPortFcphVersionLow (4)
- fcFxPortBbCredit (5)
- fcFxPortRxBufSize (6)
- fcFxPortRatov (7)
- fcFxPortEdtov (8)
- fcFxPortCosSupported (9)
- fcFxPortIntermixSupported (10)
- fcFxPortStackedConnMode (11)
- fcFxPortClass2SeqDeliv (12)
- fcFxPortClass3SeqDeliv (13)
- fcFxPortHoldTime (14)
- fcFeError (1.3.6.1.2.1.75.1.3)
- fcFxPortErrorTable (1)
- fcFxPortErrorEntry (1)
- fcFxPortLinkFailures (1)
- fcFxPortSyncLosses (2)
- fcFxPortSigLosses (3)
- fcFxPortPrimSeqProtoErrors (4)
- fcFxPortInvalidTxWords (5)
- fcFxPortInvalidCrcs (6)
- fcFxPortDelimiterErrors (7)
- fcFxPortAddressIdErrors (8)
- fcFxPortLinkResetIns (9)
- fcFxPortLinkResetOuts (10)
- fcFxPortOlsIns (11)
- fcFxPortOlsOuts (12)
- fcFeStatus (1.3.6.1.2.1.75.1.2)
- fcFxPortStatusTable (1)
- fcFxPortStatusEntry (1)
- fcFxPortID (1)
- fcFxPortBbCreditAvailable (2)
- fcFxPortOperMode (3)
- fcFxPortAdminMode (4)
- fcFxPortPhysTable (2)
- fcFxPortPhysEntry (1)
- fcFxPortPhysAdminStatus (1)
- fcFxPortPhysOperStatus (2)
- fcFxPortPhysLastChange (3)
- fcFxPortPhysRttov (4)
- fcFxloginTable (3)
- fcFxloginEntry (1)
- fcFxPortNxLoginIndex (1)
- fcFxPortFcphVersionAgreed (2)
- fcFxPortNxPortBbCredit (3)
- fcFxPortNxPortRxDataFieldSize (4)
- fcFxPortCosSuppAgreed (5)
- fcFxPortIntermixSuppAgreed (6)
- fcFxPortStackedConnModeAgreed (7)
- fcFxPortClass2SeqDelivAgreed (8)
- fcFxPortClass3SeqDelivAgreed (9)
- fcFxPortNxPortName (10)
- fcFxPortConnectedNxPort (11)
- fcFxPortBbCreditModel (12)
- fcFeCabilities (1.3.6.1.2.1.75.1.5)
- fcFxPortCapTable (1)
- fcFxPortCapEntry (1)
- fcFxPortCapFcphVersionHigh (1)
- fcFxPortCapFcphVersionLow (2)
- fcFxPortCapBbCreditMax (3)
- fcFxPortCapBbCreditMin (4)
- fcFxPortCapRxDataFieldSizeMax (5)
- fcFxPortCapRxDataFieldSizeMin (6)
- fcFxPortCapCos (7)
- fcFxPortCapIntermix (8)
- fcFxPortCapStackedConnMode (9)
- fcFxPortCapClass2SeqDeliv (10)
- fcFxPortCapClass3SeqDeliv (11)
- fcFxPortCapHoldTimeMax (12)
- fcFxPortCapHoldTimeMin (13)
- fcFeAccounting (1.3.6.1.2.1.75.1.4)
- fcFxPortC1AccountingTable (1)
- fcFxPortC1AccountingEntry (1)
- fcFxPortC1InFrames (1)
- fcFxPortC1OutFrames (2)
- fcFxPortC1InOctets (3)
- fcFxPortC1OutOctets (4)
- fcFxPortC1Discards (5)
- fcFxPortC1FbsyFrames (6)
- fcFxPortC1FrjtFrames (7)
- fcFxPortC1InConnections (8)
- fcFxPortC1OutConnections (9)
- fcFxPortC1ConnTime (10)
- fcFxPortC2AccountingTable (2)
- fcFxPortC2AccountingEntry (1)
- fcFxPortC2InFrames (1)
- fcFxPortC2OutFrames (2)
- fcFxPortC2InOctets (3)
- fcFxPortC2OutOctets (4)
- fcFxPortC2Discards (5)
- fcFxPortC2FbsyFrames (6)
- fcFxPortC2FrjtFrames (7)
- fcFxPortC3AccountingTable (3)
- fcFxPortC3AccountingEntry (1)
- fcFxPortC3InFrames (1)
- fcFxPortC3OutFrames (2)
- fcFxPortC3InOctets (3)
- fcFxPortC3OutOctets (4)
- fcFxPortC3Discards (5)
Figure 8: Tree Structure for fcFeAccounting Tables
Configuration Group
This group consists of scalar objects and tables. It contains the configuration and
service parameters of the Fabric Element and the FxPorts.
The group represents a set of parameters associated with the Fabric Element or an
FxPort to support its NxPorts.
fcFeFabricName
OID 1.3.6.1.2.1.75.1.1.1
Description The Name_Identifier of the fabric to which this fabric element
belongs.
Note: Returns the World-Wide Name (WWN) of the primary switch in the fabric.
fcFeElementName
OID 1.3.6.1.2.1.75.1.1.2
Description The Name_Identifier of the fabric element.
fcFeModuleCapacity
OID 1.3.6.1.2.1.75.1.1.3
Description The maximum number of modules in the Fabric Element,
regardless of their current state.
OID 1.3.6.1.2.1.75.1.1.4
Description A table that contains, one entry for each module in the Fabric
Element, information about the modules.
fcFeModuleEntry
OID 1.3.6.1.2.1.75.1.1.4.1
Description An entry containing the configuration parameters of a module.
Index fcFeModuleIndex
fcFeModuleIndex
OID 1.3.6.1.2.1.75.1.1.4.1.1
Description Identifies the module within the Fabric Element for which this
entry contains information. This value is never greater than
fcFeModuleCapacity.
fcFeModuleDescr
OID 1.3.6.1.2.1.75.1.1.4.1.2
Description A textual description of the module. This value should include
the full name and version identification of the module. It should
contain printable ASCII characters.
fcFeModuleObjectID
OID 1.3.6.1.2.1.75.1.1.4.1.3
Description The vendor’s authoritative identification of the module. This
value may be allocated within the SMI enterprises subtree
(1.3.6.1.4.1) and provides a straight-forward and unambiguous
means for determining what kind of module is being managed.
For example, this object could take the value
1.3.6.1.4.1.99649.3.9 if vendor “Neufe Inc.” was assigned the
subtree 1.3.6.1.4.1.99649, and had assigned the identifier
1.3.6.1.4.1.99649.3.9 to its ‘FeFiFo-16 PlugInCard.’
fcFeModuleOperStatus
OID 1.3.6.1.2.1.75.1.1.4.1.4
Description Indicates the operational status of the module. Possible values
include:
online (1): The module is functioning properly
offline (2): The module is not available
testing (3): The module is under testing
faulty (4): The module is defective in some way.
fcFeModuleLastChange
OID 1.3.6.1.2.1.75.1.1.4.1.5
Description Contains the value of sysUpTime when the module entered its
current operational status. A value of zero indicates that the
operational status of the module has not changed since the agent
last restarted.
fcFeModuleFxPortCapacity
OID 1.3.6.1.2.1.75.1.1.4.1.6
Description The number of FxPort that can be contained within the module.
Within each module, the ports are uniquely numbered in the
range from 1 to fcFeModuleFxPortCapacity inclusive. However,
the numbers are not required to be contiguous.
fcFeModuleName
OID 1.3.6.1.2.1.75.1.1.4.1.7
Description The Name_Identifier of the module.
FxPort Table
This table contains, one entry for each FxPort, the configuration parameters of the
ports.
fcFxPortTable
OID 1.3.6.1.2.1.75.1.1.5
Description A table that contains, one entry for each FxPort in the Fabric
Element, configuration and service parameters of the FxPorts.
fcFxPortEntry
OID 1.3.6.1.2.1.75.1.1.5.1
Description An entry containing the configuration and service parameters of
an FxPort.
Index fcFeModuleIndex
fcFxPortIndex
fcFxPortIndex
OID 1.3.6.1.2.1.75.1.1.5.1.1
Description Identifies the FxPort within the module. This number ranges
from 1 to the value of fcFeModulePortCapacity for the
associated module. The value remains constant for the identified
FxPort until the module is re-initialized.
fcFxPortName
OID 1.3.6.1.2.1.75.1.1.5.1.2
Description The World Wide Name of this FxPort. Each FxPort has a unique
port World Wide Name within the the fabric.
fcFxPortFcphVersionHigh
OID 1.3.6.1.2.1.75.1.1.5.1.3
Description The highest or most recent version of FC-PH that the FxPort is
configured to support.
fcFxPortFcphVersionLow
OID 1.3.6.1.2.1.75.1.1.5.1.4
Description The lowest or earliest version of FC-PH that the FxPort is
configured to support.
fcFxPortBbCredit
OID 1.3.6.1.2.1.75.1.1.5.1.5
Description3.94 The total number of receive buffers available for holding Class 1
6 connect-request, Class 2 or 3 frames from the attached NxPort.
It is for buffer-to-buffer flow control in the direction from the
attached NxPort (if applicable) to FxPort.
fcFxPortRxBufSize
1.054
OID 1.3.6.1.2.1.75.1.1.5.1.6
Description The largest Data_Field Size (in octets) for an FT_1 frame that
can be received by the FxPort.
fcFxPortRatov
OID 1.3.6.1.2.1.75.1.1.5.1.7
Description The Resource_Allocation_Timeout Value configured for the
FxPort. This is used as the time-out value for determining when
to reuse an NxPort resource such as a Recovery_Qualifier. It
represents E_D_TOV (see next object) plus twice the maximum
time that a frame may be delayed within the Fabric and still be
delivered.
fcFxPortEdtov
OID 1.3.6.1.2.1.75.1.1.5.1.8
Description The E_D_TOV value configured for the FxPort. The
Error_Detect_Timeout Value is used as the time-out value for
detecting an error condition.
fcFxPortCosSupported
OID 1.3.6.1.2.1.75.1.1.5.1.9
Description A value indicating the set of Classes of Service supported by the
FxPort.
fcFxPortIntermixSupported
d
OID 1.3.6.1.2.1.75.1.1.5.1.10
Description A flag indicating whether the FxPort
supports an Intermixed Dedicated
Connection.
fcFxPortStackedConnMode
OID 1.3.6.1.2.1.75.1.1.5.1.11
Description A value indicating the mode of Stacked Connect supported by
the FxPort.
fcFxPortClass2SeqDeliv
OID 1.3.6.1.2.1.75.1.1.5.1.12
Description A flag indicating whether Class 2 Sequential Delivery is
supported by the FxPort.
fcFxPortClass3SeqDeliv
OID 1.3.6.1.2.1.75.1.1.5.1.13
Description A flag indicating whether Class 3 Sequential Delivery is
supported by the FxPort.
fcFxPortHoldTime
OID 1.3.6.1.2.1.75.1.1.5.1.14
Description The maximum time (in microseconds) that the FxPort shall hold
a frame before discarding the frame if it is unable to deliver the
frame. The value 0 means that the FxPort does not support this
parameter.
Status Group
This group consists of tables that contain operational status and established
service parameters for the Fabric Element and the attached NxPorts.
OID 1.3.6.1.2.1.75.1.2.1
Description A table that contains, one entry for each FxPort in the Fabric
Element, operational status and parameters of the FxPorts.
fcFxPortStatusEntry
OID 1.3.6.1.2.1.75.1.2.1.1
Description An entry containing operational status and parameters of an
FxPort.
Index fcFeModuleIndex
fcFxPortIndex
fcFxPortID
OID 1.3.6.1.2.1.75.1.2.1.1.1
Description The address identifier by which this FxPort is identified within
the Fabric. The FxPort may assign its address identifier to its
attached NxPort(s) during Fabric Login.
fcFxPortBbCreditAvailable
OID 1.3.6.1.2.1.75.1.2.1.1.2
Description The number of buffers currently available for receiving frames
from the attached port in the buffer-to-buffer flow control. The
value should be less than or equal to fcFxPortBbCredit.
fcFxPortOperMode
OID 1.3.6.1.2.1.75.1.2.1.1.3
Description The current operational mode of the FxPort:
unknown (1)
fPort (2)
flPort (3)
fcFxPortAdminMode
OID 1.3.6.1.2.1.75.1.2.1.1.4
Description The desired operational mode of the FxPort.
OID 1.3.6.1.2.1.75.1.2.2
Description A table that contains, one entry for each FxPort in the Fabric
Element, physical level status and parameters of the FxPorts.
fcFxPortPhysEntry
OID 1.3.6.1.2.1.75.1.2.2.1
Description An entry containing physical level status and parameters of an
FxPort.
Index fcFeModuleIndex
fcFxPortIndex
fcFxPortPhysAdminStatus
OID 1.3.6.1.2.1.75.1.2.2.1.1
Description The desired state of the FxPort. A management station may
place the FxPort in a desired state by setting this object
accordingly. Possible values are:
online (1): Place port online.
offline (2): Take port offline.
testing (3): Initiate test procedures
The testing (3) state indicates that no operational frames can be
passed. When a Fabric Element initializes, all FxPorts start with
fcFxPortPhysAdminStatus in the offline (2) state. As the result
of either explicit management action or per configuration
information accessible by the Fabric Element,
fcFxPortPhysAdminStatus is then changed to either the online
(1) or testing (3) states, or remains in the offline (2) state.
fcFxPortPhysOperStatus
OID 1.3.6.1.2.1.75.1.2.2.1.2
Description The current operational status of the FxPort. Possibles values
are:
online (1): Login may proceed.
offline (2): Login cannot proceed.
testing (3): Port is under test.
linkFailure (4): Failure after online/testing.
The testing (3) state indicates that no operational frames can be
passed. If fcFxPortPhysAdminStatus is offline (2) then
fcFxPortPhysOperStatus should be offline (2). If
fcFxPortPhysAdminStatus is changed to online (1) then
fcFxPortPhysOperStatus should change to online (1) if the
FxPort is ready to accept Fabric Login request from the attached
NxPort; it should proceed and remain in the linkFailure (4) state
if and only if there is a fault that prevents it from going to the
online (1) state.
fcFxPortPhysLastChange
OID 1.3.6.1.2.1.75.1.2.2.1.3
Description The value of sysUpTime at the time the FxPort entered its
current operational status. A value of zero indicates that the
FxPort’s operational status has not changed since the agent last
restarted.
fcFxPortPhysRttov
OID 1.3.6.1.2.1.75.1.2.2.1.4
Description The Receiver_Transmitter_Timeout value of the FxPort. This is
used by the receiver logic to detect Loss of Synchronization.
Note: This object is read only. It is listed in the MIB definition as read-write (which is
incorrect).
OID 1.3.6.1.2.1.75.1.2.3.
Description A table that contains, one entry for each FxPort in the Fabric
Element, services parameters established from the most recent
Fabric Login, explicit or implicit.
fcFxloginEntry
OID 1.3.6.1.2.1.75.1.2.3.1
Description An entry containing service parameters established from a
successful Fabric Login.
Index fcFxloginModuleIndex, fcFxloginFxPortIndex,
fcFxloginNxPortIndex
fcFxPortNxLoginIndex
OID 1.3.6.1.2.1.75.1.2.3.1.1
Description The associated NxPort in the attachment for which the entry
contains information.
fcFxPortFcphVersionAgreed
OID 1.3.6.1.2.1.75.1.2.3.1.2
Description The version of FC-PH that the FxPort has agreed to support
from the Fabric Login.
fcFxPortNxPortBbCredit
OID 1.3.6.1.2.1.75.1.2.3.1.3
Description The total number of buffers available for holding Class 1
connect-request, Class 2 or Class 3 frames to be transmitted to
the attached NxPort. It is for buffer-to-buffer flow control in the
direction from FxPort to NxPort. The buffer-to-buffer flow
control mechanism is indicated in the respective
fcFxPortBbCreditModel.
fcFxPortNxPortRxDataFieldSize
OID 1.3.6.1.2.1.75.1.2.3.1.4
Description The Receive Data Field Size of the attached NxPort. This is a
binary value that specifies the largest Data Field Size for an
FT_1 frame that can be received by the NxPort. The value is in
number of bytes and ranges from 128 to 2112 inclusive.
fcFxPortCosSuppAgreed
OID 1.3.6.1.2.1.75.1.2.3.1.5
Description Indicates that the attached NxPort has requested the FxPort for
the support of classes of services and the FxPort has granted the
request.
fcFxPortIntermixSuppAgreed
OID 1.3.6.1.2.1.75.1.2.3.1.6
Description A variable indicating that the attached NxPort has requested the
FxPort for the support of Intermix, and the FxPort has granted
the request. This flag is only valid if Class 1 service is
supported. Possible values are:
yes (1): The attached NxPort has requested the FxPort
for the support of Intermix, and the FxPort has
granted the request.
no (2): The attached NxPort has not requested the
FxPort for the support of Intermix.
fcFxPortStackedConnModeAgreed
OID 1.3.6.1.2.1.75.1.2.3.1.7
Description Indicates whether the FxPort has agreed to support stacked
connect from the Fabric Login. This is only meaningful if
Class 1 service has been agreed to.
fcFxPortClass2SeqDelivAgreed
OID 1.3.6.1.2.1.75.1.2.3.1.8
Description A variable indicating whether the FxPort has agreed to support
Class 2 sequential delivery from the Fabric Login. This is only
meaningful if Class 2 service has been agreed. Possible values
are:
yes (1): The FxPort has agreed to support Class 2
sequential delivery from the Fabric Login.
no (2): The FxPort has not agreed to support Class 2
sequential delivery from the Fabric Login.
fcFxPortClass3SeqDelivAgreed
OID 1.3.6.1.2.1.75.1.2.3.1.9
Description A flag indicating whether the FxPort has agreed to support Class
3 sequential delivery from the Fabric Login. This is only
meaningful if Class 3 service has been agreed. Possible values
are:
yes (1): The FxPort has agreed to support Class 3
sequential delivery from the Fabric Login.
no (2): The FxPort has not agreed to support Class 3
sequential delivery from the Fabric Login.
fcFxPortNxPortName
OID 1.3.6.1.2.1.75.1.2.3.1.10
Description The port name of the attached NxPort, if applicable. If the value
of this object is ‘0000000000000000’H, this FxPort has no
NxPort attached to it.
fcFxPortConnectedNxPort
OID 1.3.6.1.2.1.75.1.2.3.1.11
Description The address identifier of the destination FxPort with which this
FxPort is currently engaged in a either a Class 1 or loop
connection. If the value of this object is ‘000000’H, this FxPort
is not engaged in a connection.
fcFxPortBbCreditModel
OID 1.3.6.1.2.1.75.1.2.3.1.12
Description Identifies the BB_Credit model used by the FxPort. The regular
model refers to the buffer-to-buffer flow control mechanism
defined in FC-PH [1] is used between the F_Port and the
N_Port. For FL_Ports, the Alternate Buffer-to-Buffer flow
control mechanism as defined in FC-AL [4] is used between the
FL_Port and any attached NL_Ports.
Error Group
This group consists of tables that contain information about the various types of
errors detected. The management station may use the information in this group to
determine the quality of the link between the FxPort and its attached NxPort.
Implementation of this group is optional.
Note: The first 6 columnar objects after the port index correspond to the counters in the
Link ErrorStatus Block.
fcFxPortErrorTable
OID 1.3.6.1.2.1.75.1.3.1
Description A table that contains, one entry for each FxPort, counters that
record the numbers of errors detected.
fcFxPortErrorEntry
OID 1.3.6.1.2.1.75.1.3.1.1
Description An entry containing error counters of a FxPort.
Index fcFxPortErrorModuleIndex, fcFxPortErrorFxPortIndex
fcFxPortLinkFailures
OID 1.3.6.1.2.1.75.1.3.1.1.1
Description The number of link failures detected by this FxPort.
fcFxPortSyncLosses
OID 1.3.6.1.2.1.75.1.3.1.1.2
Description The number of loss of synchronization detected by the FxPort.
fcFxPortSigLosses
OID 1.3.6.1.2.1.75.1.3.1.1.3
Description The number of loss of signal detected by the FxPort.
fcFxPortPrimSeqProtoErrors
OID 1.3.6.1.2.1.75.1.3.1.1.4
Description The number of primitive sequence protocol errors detected by
the FxPort.
fcFxPortInvalidTxWords
OID 1.3.6.1.2.1.75.1.3.1.1.5
Description The number of invalid transmission word detected by the
FxPort.
fcFxPortInvalidCrcs
OID 1.3.6.1.2.1.75.1.3.1.1.6
Description The number of invalid Cyclic Redundancy Checks (CRCs)
detected by this FxPort.
fcFxPortDelimiterErrors
OID 1.3.6.1.2.1.75.1.3.1.1.7
Description The number of Delimiter Errors detected by this FxPort.
fcFxPortAddressIdErrors
OID 1.3.6.1.2.1.75.1.3.1.1.8
Description The number of address identifier errors detected by this FxPort.
fcFxPortLinkResetIns
OID 1.3.6.1.2.1.75.1.3.1.1.9
Description The number of Link Reset Protocol received by this FxPort from
the attached NxPort.
fcFxPortLinkResetOuts
OID 1.3.6.1.2.1.75.1.3.1.1.10
Description The number of Link Reset Protocol issued by this FxPort to the
attached NxPort.
fcFxPortOlsIns
OID 1.3.6.1.2.1.75.1.3.1.1.11
Description The number of Offline Sequence received by this FxPort.
fcFxPortOlsOuts
OID 1.3.6.1.2.1.75.1.3.1.1.12
Description The number of Offline Sequence issued by this FxPort.
Accounting Group
The Accounting group is supported only in Fabric OS v4.x. It is not supported in
Fabric OS v3.x.
The Accounting group consists of the following tables:
■ Class 1 accounting table
■ Class 2 accounting table
■ Class 3 accounting table
Each table contains accounting information for the FxPorts in the Fabric Element.
OID 1.3.6.1.2.1.75.1.4.1
Description A table that contains, one entry for each FxPort in the Fabric
Element, Class 1 accounting information recorded since the
management agent has re-initialized.
fcFxPortC1AccountingEntry
OID 1.3.6.1.2.1.75.1.4.1.1
Description An entry containing Class 1 accounting information for each
FxPort.
Index fcFeModuleIndex
fcFePortIndex
fcFxPortC1InFrames
OID 1.3.6.1.2.1.75.1.4.1.1.1
Description The number of Class 1 frames (other than Class 1
connect-request) received by this FxPort from its attached
NxPort.
fcFxPortC1OutFrames
OID 1.3.6.1.2.1.75.1.4.1.1.2
Description The number of Class 1 frames (other than Class 1 connect-
request) delivered through this FxPort to its attached NxPort.
fcFxPortC1InOctets
OID 1.3.6.1.2.1.75.1.4.1.1.3
Description The number of Class 1 frame octets, including the frame
delimiters, received by this FxPort from its attached NxPort.
fcFxPortC1OutOctets
OID 1.3.6.1.2.1.75.1.4.1.1.4
Description The number of Class 1 frame octets, including the frame
delimiters, delivered through this FxPort its attached NxPort.
fcFxPortC1Discards
OID 1.3.6.1.2.1.75.1.4.1.1.5
Description The number of Class 1 frames discarded by this FxPort.
fcFxPortC1FbsyFrames
OID 1.3.6.1.2.1.75.1.4.1.1.6
Description The number of F_BSY frames generated by this FxPort against
Class 1 connect-request.
fcFxPortC1FrjtFrames
OID 1.3.6.1.2.1.75.1.4.1.1.7
Description The number of F_RJT frames generated by this FxPort against
Class 1 connect-request.
fcFxPortC1InConnections
OID 1.3.6.1.2.1.75.1.4.1.1.8
Description The number of Class 1 connections successfully established in
which the attached NxPort is the source of the connect- request.
fcFxPortC1OutConnections
OID 1.3.6.1.2.1.75.1.4.1.1.9
Description The number of Class 1 connections successfully established in
which the attached NxPort is the destination of the
connect-request.
fcFxPortC1ConnTime
OID 1.3.6.1.2.1.75.1.4.1.1.10
Description The cumulative time that this FxPort has been engaged in Class
1 connection. The amount of time is counted from after a
connect-request has been accepted until the connection is
disengaged, either by an EOFdt or Link Reset.
OID 1.3.6.1.2.1.75.1.4.2
Description A table that contains, one entry for each FxPort in the Fabric
Element, Class 2 accounting information recorded since the
management agent has re-initialized.
fcFxPortC2AccountingEntry
OID 1.3.6.1.2.1.75.1.4.2.1
Description An entry containing Class 2 accounting information for each
FxPort.
Index fcFeModuleIndex
fcFePortIndex
fcFxPortC2InFrames
OID 1.3.6.1.2.1.75.1.4.2.1.1
Description The number of Class 2 frames received by this FxPort from its
attached NxPort.
fcFxPortC2OutFrames
OID 1.3.6.1.2.1.75.1.4.2.1.2
Description The number of Class 2 frames delivered through this FxPort to
its attached NxPort.
fcFxPortC2InOctets
OID 1.3.6.1.2.1.75.1.4.2.1.3
Description The number of Class 2 frame octets, including the frame
delimiters, received by this FxPort from its attached NxPort.
fcFxPortC2OutOctets
OID 1.3.6.1.2.1.75.1.4.2.1.4
Description The number of Class 2 frame octets, including the frame
delimiters, delivered through this FxPort to its attached NxPort.
fcFxPortC2Discards
OID 1.3.6.1.2.1.75.1.4.2.1.5
Description The number of Class 2 frames discarded by this FxPort.
fcFxPortC2FbsyFrames
OID 1.3.6.1.2.1.75.1.4.2.1.6
Description The number of F_BSY frames generated by this FxPort against
Class 2 frames.
fcFxPortC2FrjtFrames
OID 1.3.6.1.2.1.75.1.4.2.1.7
Description The number of F_RJT frames generated by this FxPort against
Class 2 frames.
OID 1.3.6.1.2.1.75.1.4.3
Description A table that contains, one entry for each FxPort in the Fabric
Element, Class 3 accounting information recorded since the
management agent has re-initialized.
fcFxPortC3AccountingEntry
OID 1.3.6.1.2.1.75.1.4.3.1
Description An entry containing Class 3 accounting information for each
FxPort.
Index fcFeModuleIndexfcFePortIndex
fcFxPortC3InFrames
OID 1.3.6.1.2.1.75.1.4.3.1.1
Description The number of Class 3 frames received by this FxPort from its
attached NxPort.
fcFxPortC3OutFrames
OID 1.3.6.1.2.1.75.1.4.3.1.2
Description The number of Class 3 frames delivered through this FxPort to
its attached NxPort.
fcFxPortC3InOctets
OID 1.3.6.1.2.1.75.1.4.3.1.3
Description The number of Class 3 frame octets, including the frame
delimiters, received by this FxPort from its attached NxPort.
fcFxPortC3OutOctets
OID 1.3.6.1.2.1.75.1.4.3.1.4
Description The number of Class 3 frame octets, including the frame
delimiters, delivered through this FxPort to its attached NxPort.
fcFxPortC3Discards
OID 1.3.6.1.2.1.75.1.4.3.1.5
Description The number of Class 3 frames discarded by this FxPort.
Capability Group
This group consists of a table describing information about what each FxPort is
inherently capable of operating or supporting. A capability may be used, as
expressed in its respective object value in the Configuration group.
Implementation of this group is optional.
OID 1.3.6.1.2.1.75.1.5.1
Description A table that contains, one entry for each FxPort, the capabilities
of the port within the Fabric Element.
fcFxPortCapEntry
OID 1.3.6.1.2.1.75.1.5.1.1
Description An entry containing the capabilities of a FxPort.
Index fcFxPortCapModuleIndex, fcFxPortCapFxPortIndex
fcFxPortCapFcphVersionHigh
OID 1.3.6.1.2.1.75.1.5.1.1.1
Description The highest or most recent version of FC-PH that the FxPort is
capable of supporting.
fcFxPortCapFcphVersionLow
OID 1.3.6.1.2.1.75.1.5.1.1.2
Description The lowest or earliest version of FC-PH that the FxPort is
capable of supporting.
fcFxPortCapBbCreditMax
OID 1.3.6.1.2.1.75.1.5.1.1.3
Description The maximum number of receive buffers available for holding
Class 1 connect-request, Class 2 or Class 3 frames from the
attached NxPort.
fcFxPortCapBbCreditMin
OID 1.3.6.1.2.1.75.1.5.1.1.4
Description The minimum number of receive buffers available for holding
Class 1 connect-request, Class 2 or Class 3 frames from the
attached NxPort.
fcFxPortCapRxDataFieldSizeMax
OID 1.3.6.1.2.1.75.1.5.1.1.5
Description The maximum size in bytes of the Data Field in a frame that the
FxPort is capable of receiving from its attached NxPort.
fcFxPortCapRxDataFieldSizeMin
OID 1.3.6.1.2.1.75.1.5.1.1.6
Description The minimum size in bytes of the Data Field in a frame that the
FxPort is capable of receiving from its attached NxPort.
fcFxPortCapCos
OID 1.3.6.1.2.1.75.1.5.1.1.7
Description A value indicating the set of Classes of Service that the FxPort is
capable of supporting.
fcFxPortCapIntermix
OID 1.3.6.1.2.1.75.1.5.1.1.8
Description A flag indicating whether the FxPort is capable of supporting
the intermixing of Class 2 and Class 3 frames during a Class 1
connection. This flag is only valid if the port is capable of
supporting Class 1 service. Possible values are:
yes (1): The FxPort is capable of supporting the
intermixing of Class 2 and Class 3 frames during
a Class 1 connection.
no (2): The FxPort is not capable of supporting the
intermixing of Class 2 and Class 3 frames during
a Class 1 connection.
fcFxPortCapStackedConnMode
OID 1.3.6.1.2.1.75.1.5.1.1.9
Description A value indicating the mode of Stacked Connect request that the
FxPort is capable of supporting.
fcFxPortCapClass2SeqDeliv
OID 1.3.6.1.2.1.75.1.5.1.1.10
Description A flag indicating whether the FxPort is capable of supporting
Class 2 Sequential Delivery. Possible values are:
yes (1): The FxPort is capable of supporting Class 2
Sequential Delivery.
no (2): The FxPort is not capable of supporting Class 2
Sequential Delivery.
fcFxPortCapClass3SeqDeliv
OID 1.3.6.1.2.1.75.1.5.1.1.11
Description A flag indicating whether the FxPort is capable of supporting
Class 3 Sequential Delivery. Possible values are:
yes (1): The FxPort is capable of supporting Class 3
Sequential Delivery.
no (2): The FxPort is not capable of supporting Class 3
Sequential Delivery.
fcFxPortCapHoldTimeMax
OID 1.3.6.1.2.1.75.1.5.1.1.12
Description The maximum holding time (in microseconds) that the FxPort is
capable of supporting.
fcFxPortCapHoldTimeMin
OID 1.3.6.1.2.1.75.1.5.1.1.13
Description The minimum holding time (in microseconds) that the FxPort is
capable of supporting.
Overview
Note: HP does not support the settable “Write” function for any of the Fibre Channel
FE MIB objects except fcFxPortPhyAdminStatus.
The descriptions of each of the MIB variables in this chapter come directly from
the FCFABRIC-ELEMENT-MIB itself. The notes that follow the descriptions
typically pertain to HP-specific information and are provided by HP.
The object types in FCFABRIC-ELEMENT-MIB are organized into the following
groups:
■ Configuration
■ Operational
■ Error
■ Accounting (not supported)
■ Capability
FCFABRIC-ELEMENT-MIB Organization
Figure 9 through Figure 12 depict the organization and structure of
FCFABRIC-ELEMENT-MIB.
- iso (1)
- org (3)
- dod (6)
- internet (1)
- experimental (3)
- fibreChannel (42)
- fcFabric (2)
- fcFe (1)
- fcFeConfig (1)
- fcFabricName (1)
- fcElementName (2)
- fcFeModuleCapacity (3)
- fcFeModuleTable (4)
- fcFxConfTable (5)
- fcFeOp (2)
- fcFxPortOperTable (1)
- fcFxPortPhysTable (3)
- fcFxlogiTable (4)
- fcFeError (3)
- fcFxPortErrorTable (1)
- fcFeAcct (4)
- fcFxPortC1AcctTable (1)
- fcFxPortC2AcctTable (2)
- fcFxPortC3AcctTable (3)
- fcFeCap (5)
- fcFxPortCapTable (1)
- fcFeConfig (1.3.6.1.3.42.2.1.1)
- fcFabricName (1)
- fcElementName (2)
- fcFeModuleCapacity (3)
- fcFeModuleTable (4)
- fcFeModuleEntry (1)
- fcFeModuleIndex (1)
- fcFeModuleDescr (2)
- fcFeModuleObjectID (3)
- fcFeModuleOperStatus (4)
- fcFeModuleLastChange (5)
- fcFeModuleFxPortCapacity (6)
- fcFeModuleName (7)
- fcFxConfTable (5)
- fcFxConfEntry (1)
- fcFxConfModuleIndex (1)
- fcFxConfFxPortIndex (2)
- fcFxPortName (3)
- fcFxPortFcphVersionHigh (4)
- fcFxPortFcphVersionLow (5)
- fcFxPortBbCredit (6)
- fcFxPortRxBufSize (7)
- fcFxPortRatov (8)
- fcFxPortEdtov (9)
- fcFxPortCosSupported (10)
- fcFxPortIntermixSupported (11)
- fcFxPortStackedConnMode (12)
- fcFxPortClass2SeqDeliv (13)
- fcFxPortClass3SeqDeliv (14)
- fcFxPortHoldTime (15)
- fcFxPortBaudRate (16)
- fcFxPortMedium (17)
- fcFxPortTxType (18)
- fcFxPortDistance (19)
- fcFeOp (1.3.6.1.3.42.2.1.2)
- fcFxPortOperTable (1)
- fcFxPortOperEntry (1)
- fcFxPortOperModuleIndex (1)
- fcFxPortOperFxPortIndex (2)
- fcFxPortID (3)
- fcFPortAttachedPortName (4)
- fcFPortConnectedPort (5)
- fcFxPortBbCreditAvailable (6)
- fcFxPortOperMode (7)
- fcFxPortAdminMode (8)
- fcFxPortPhysTable (3)
- fcFxPortPhysEntry (1)
- fcFxPortPhysModuleIndex (1)
- fcFxPortPhysFxPortIndex (2)
- fcFxPortPhysAdminStatus (3)
- fcFxPortPhysOperStatus (4)
- fcFxPortPhysLastChange (5)
- fcFxPortPhysRttov (6)
- fcFxlogiTable (4)
- fcFxlogiEntry (1)
- fcFxlogiModuleIndex (1)
- fcFxlogiFxPortIndex (2)
- fcFxlogiNxPortIndex (3)
- fcFxPortFcphVersionAgreed (4)
- fcFxPortNxPortBbCredit (5)
- fcFxPortNxPortRxDataFieldSize (6)
- fcFxPortCosSuppAgreed (7)
- fcFxPortIntermixSuppAgreed (8)
- fcFxPortStackedConnModeAgreed (9)
- fcFxPortClass2SeqDelivAgreed (10)
- fcFxPortClass3SeqDelivAgreed (11)
- fcFxPortNxPortName (12)
- fcFxPortConnectedNxPort (13)
- fcFxPortBbCreditModel (14)
- fcFeError (1.3.6.1.3.42.2.1.3)
- fcFxPortErrorTable (1)
- fcFxPortErrorEntry (1)
- fcFxPortErrorModuleIndex (1)
- fcFxPortErrorFxPortIndex (2)
- fcFxPortLinkFailures (3)
- fcFxPortSyncLosses (4)
- fcFxPortSigLosses (5)
- fcFxPortPrimSeqProtoErrors (6)
- fcFxPortInvalidTxWords (7)
- fcFxPortInvalidCrcs (8)
- fcFxPortDelimiterErrors (9)
- fcFxPortAddressIdErrors (10)
- fcFxPortLinkResetIns (11)
- fcFxPortLinkResetOuts (12)
- fcFxPortOlsIns (13)
- fcFxPortOlsOuts (14)
- fcFeAcct (1.3.6.1.3.42.2.1.4)
(-- Not Supported --)
- fcFeCap (1.3.6.1.3.42.2.1.5)
- fcFxPortCapTable (1)
- fcFxPortCapEntry (1)
- fcFxPortCapModuleIndex (1)
- fcFxPortCapFxPortIndex (2)
- fcFxPortCapFcphVersionHigh (3)
- fcFxPortCapFcphVersionLow (4)
- fcFxPortCapBbCreditMax (5)
- fcFxPortCapBbCreditMin (6)
- fcFxPortCapRxDataFieldSizeMax (7)
- fcFxPortCapRxDataFieldSizeMin (8)
- fcFxPortCapCos (9)
- fcFxPortCapIntermix (10)
- fcFxPortCapStackedConnMode (11)
- fcFxPortCapClass2SeqDeliv (12)
- fcFxPortCapClass3SeqDeliv (13)
- fcFxPortCapHoldTimeMax (14)
- fcFxPortCapHoldTimeMin (15)
- fcFxPortCapBaudRates (16)
- fcFxPortCapMedia (17)
Figure 12: Tree Structure for fcFeError, fcFeAcct, and fcFeCap Tables
Configuration Group
This group consists of scalar objects and tables. It contains the configuration and
service parameters of the Fabric Element and the FxPorts.
The group represents a set of parameters associated with the Fabric Element or an
FxPort to support its NxPorts.
OID 1.3.6.1.3.42.2.1.1.1
Description The Name_Identifier of the fabric to which this fabric element
belongs.
fcElementName
OID 1.3.6.1.3.42.2.1.1.2
Description The Name_Identifier of the fabric element.
fcFeModuleCapacity
OID 1.3.6.1.3.42.2.1.1.3
Description The maximum number of modules in the Fabric Element,
regardless of their current state.
OID 1.3.6.1.3.42.2.1.1.4
Description A table that contains, one entry for each module in the Fabric
Element, information about the modules.
fcFeModuleEntry
OID 1.3.6.1.3.42.2.1.1.4.1
Status Mandatory
Description An entry containing the configuration parameters of a module.
Index fcFeModuleIndex
fcFeModuleIndex
OID 1.3.6.1.3.42.2.1.1.4.1.1
Description Identifies the module within the Fabric Element for which this
entry contains information. This value is never greater than
fcFeModuleCapacity.
fcFeModuleDescr
OID 1.3.6.1.3.42.2.1.1.4.1.2
Description A textual description of the module. This value should include
the full name and version identification of the module. It should
contain printable ASCII characters.
fcFeModuleObjectID
OID 1.3.6.1.3.42.2.1.1.4.1.3
Description The vendor’s authoritative identification of the module. This
value may be allocated within the SMI enterprises subtree
(1.3.6.1.4.1) and provides a straight-forward and unambiguous
means for determining what kind of module is being managed.
For example, this object could take the value
1.3.6.1.4.1.99649.3.9 if vendor “Neufe Inc.” was assigned the
subtree 1.3.6.1.4.1.99649, and had assigned the identifier
1.3.6.1.4.1.99649.3.9 to its ‘FeFiFo-16 PlugInCard.’
fcFeModuleOperStatus
OID 1.3.6.1.3.42.2.1.1.4.1.4
Description Indicates the operational status of the module. Possible values
are:
online (1): The module is functioning properly.
offline (2): The module is not available.
testing (3): The module is under testing.
faulty (4): The module is defective in some way.
fcFeModuleLastChange
OID 1.3.6.1.3.42.2.1.1.4.1.5
Description Contains the value of sysUpTime when the module entered its
current operational status. A value of zero indicates that the
operational status of the module has not changed since the agent
last restarted.
fcFeModuleFxPortCapacity
OID 1.3.6.1.3.42.2.1.1.4.1.6
Description The number of FxPort that can be contained within the module.
Within each module, the ports are uniquely numbered in the
range from 1 to fcFeModuleFxPortCapacity inclusive. However,
the numbers are not required to be contiguous.
fcFeModuleName
OID 1.3.6.1.3.42.2.1.1.4.1.7
Description The Name_Identifier of the module.
OID 1.3.6.1.3.42.2.1.1.5
Description A table that contains one entry for each FxPort in the Fabric
Element and configuration and service parameters for the
FxPorts.
fcFxConfEntry
OID 1.3.6.1.3.42.2.1.1.5.1
Description An entry containing the configuration and service parameters
for an FxPort.
Index FcFxConfModuleIndex, fcFxConfFxPortIndex
fcFxConfModuleIndex
OID 1.3.6.1.3.42.2.1.1.5.1.1
Description Identifies the module containing the FxPort for which this entry
contains information.
fcFxConfFxPortIndex
OID 1.3.6.1.3.42.2.1.1.5.1.2
Description Identifies the FxPort within the module. This number ranges
from 1 to the value of fcFeModulePortCapacity for the
associated module. The value remains constant for the identified
FxPort until the module is re-initialized.
fcFxPortName
OID 1.3.6.1.3.42.2.1.1.5.1.3
Description The name identifier of this FxPort. Each FxPort has a unique
port name within the address space of the fabric.
fcFxPortFcphVersionHigh
OID 1.3.6.1.3.42.2.1.1.5.1.4
Description The highest or most recent version of FC-PH that the FxPort is
configured to support.
fcFxPortFcphVersionLow
OID 1.3.6.1.3.42.2.1.1.5.1.5
Description The lowest or earliest version of FC-PH that the FxPort is
configured to support.
fcFxPortBbCredit
OID 1.3.6.1.3.42.2.1.1.5.1.6
Description The total number of receive buffers available for holding Class 1
connect-request, Class 2 or 3 frames from the attached NxPort.
It is for buffer-to-buffer flow control in the direction from the
attached NxPort (if applicable) to FxPort.
fcFxPortRxBufSize
OID 1.3.6.1.3.42.2.1.1.5.1.7
Description The largest Data_Field Size (in octets) for an FT_1 frame that
can be received by the FxPort.
fcFxPortRatov
OID 1.3.6.1.3.42.2.1.1.5.1.8
Description The Resource_Allocation_Timeout Value configured for the
FxPort. This is used as the time-out value for determining when
to reuse an NxPort resource such as a Recovery_Qualifier. It
represents E_D_TOV (see next object) plus twice the maximum
time that a frame may be delayed within the Fabric and still be
delivered.
fcFxPortEdtov
OID 1.3.6.1.3.42.2.1.1.5.1.9
Description The E_D_TOV value configured for the FxPort. The
Error_Detect_Timeout Value is used as the time-out value for
detecting an error condition.
fcFxPortCosSupported
OID 1.3.6.1.3.42.2.1.1.5.1.10
Description A value indicating the set of Classes of Service supported by the
FxPort.
fcFxPortIntermixSupported
OID 1.3.6.1.3.42.2.1.1.5.1.11
Description A flag indicating whether the FxPort supports an Intermixed
Dedicated Connection. Possible values are:
yes (1): FxPort supports an Intermixed Dedicated
Connection.
no (2): FxPort does not support an Intermixed
Dedicated Connection.
fcFxPortStackedConnMode
OID 1.3.6.1.3.42.2.1.1.5.1.12
Description A value indicating the mode of Stacked Connect supported by
the FxPort.
fcFxPortClass2SeqDeliv
OID 1.3.6.1.3.42.2.1.1.5.1.13
Description A flag indicating whether Class 2 Sequential Delivery is
supported by the FxPort. Possible values are:
yes (1): Class 2 Sequential Delivery is supported by the
FxPort.
no (2): Class 2 Sequential Delivery is not supported by
the FxPort.
fcFxPortClass3SeqDeliv
OID 1.3.6.1.3.42.2.1.1.5.1.14
Description A flag indicating whether Class 3 Sequential Delivery is
supported by the FxPort. Possible values are:
yes (1): Class 3 Sequential Delivery is supported by the
FxPort.
no (2): Class 3 Sequential Delivery is not supported by
the FxPort.
fcFxPortHoldTime
OID 1.3.6.1.3.42.2.1.1.5.1.15
Description The maximum time (in microseconds) that the FxPort shall hold
a frame before discarding the frame if it is unable to deliver the
frame. The value 0 means that the FxPort does not support this
parameter.
fcFxPortBaudRate
OID 1.3.6.1.3.42.2.1.1.5.1.16
Description The FC-0 baud rate of the FxPort.
fcFxPortMedium
OID 1.3.6.1.3.42.2.1.1.5.1.17
Description The FC-0 medium of the FxPort.
fcFxPortTxType
OID 1.3.6.1.3.42.2.1.1.5.1.18
Description The FC-0 transmitter type of the FxPort.
fcFxPortDistance
OID 1.3.6.1.3.42.2.1.1.5.1.19
Description The FC-0 distance range of the FxPort transmitter.
Operation Group
This group consists of tables that contain operational status and established
service parameters for the Fabric Element and the attached NxPorts.
OID 1.3.6.1.3.42.2.1.2.1
Description A table that contains one entry for each FxPort in the Fabric
Element, operational status, and parameters of the FxPorts.
fcFxPortOperEntry
OID 1.3.6.1.3.42.2.1.2.1.1
fcFxPortOperModuleIndex
OID 1.3.6.1.3.42.2.1.2.1.1.1
Description Identifies the module containing the FxPort for which this entry
contains information.
fcFxPortOperFxPortIndex
OID 1.3.6.1.3.42.2.1.2.1.1.2
Description Identifies the FxPort within the module. This number ranges
from 1 to the value of fcFeModulePortCapacity for the
associated module. The value remains constant for the identified
FxPort until the module is re-initialized.
fcFxPortID
OID 1.3.6.1.3.42.2.1.2.1.1.3
Description The address identifier by which this FxPort is identified within
the Fabric. The FxPort may assign its address identifier to its
attached NxPort(s) during Fabric Login.
fcFPortAttachedPortName
OID 1.3.6.1.3.42.2.1.2.1.1.4
Description The port name of the attached N_Port, if applicable. If the value
of this object is ‘0000000000000000’H, this FxPort has no
NxPort attached to it. This variable has been deprecated and
may be implemented for backward compatibility.
fcFPortConnectedPort
OID 1.3.6.1.3.42.2.1.2.1.1.5
Description The address identifier of the destination FxPort with which this
FxPort is currently engaged in either a Class 1 or loop
connection. If the value of this object is ‘000000’H, this FxPort
is not engaged in a connection. This variable has been
deprecated and may be implemented for backward
compatibility.
fcFxPortBbCreditAvailable
OID 1.3.6.1.3.42.2.1.2.1.1.6
Description The number of buffers currently available for receiving frames
from the attached port in the buffer-to-buffer flow control. The
value should be less than or equal to fcFxPortBbCredit.
fcFxPortOperMode
OID 1.3.6.1.3.42.2.1.2.1.1.7
Description The current operational mode of the FxPort.
fcFxPortAdminMode
OID 1.3.6.1.3.42.2.1.2.1.1.8
Description The desired operational mode of the FxPort.
OID 1.3.6.1.3.42.2.1.2.3
Description A table that contains one entry for each FxPort in the Fabric
Element and physical level status and parameters of the FxPorts.
fcFxPortPhysEntry
OID 1.3.6.1.3.42.2.1.2.3.1
Description An entry containing physical level status and parameters of a
FxPort.
Index fcFxPortPhysModuleIndex, fcFxPortPhysFxPortIndex
fcFxPortPhysModuleIndex
OID 1.3.6.1.3.42.2.1.2.3.1.1
Description Identifies the module containing the FxPort for which this entry
contains information.
fcFxPortPhysFxPortIndex
OID 1.3.6.1.3.42.2.1.2.3.1.2
Description Identifies the FxPort within the module. This number ranges
from 1 to the value of fcFeModulePortCapacity for the
associated module. The value remains constant for the identified
FxPort until the module is re-initialized.
fcFxPortPhysAdminStatus
OID 1.3.6.1.3.42.2.1.2.3.1.3
Description The desired state of the FxPort. Possible values are:
online (1): Place port online.
offline (2): Take port offline.
testing (3): Initiate test procedures.
A management station may place the FxPort in a desired state
by setting this object accordingly. The testing (3) state indicates
that no operational frames can be passed. When a Fabric
Element initializes, all FxPorts start with
fcFxPortPhysAdminStatus in the offline (2) state. As the result
of either explicit management action or per configuration
information accessible by the Fabric Element,
fcFxPortPhysAdminStatus is then changed to either the online
(1) or testing (3) states, or remains in the offline (2) state.
fcFxPortPhysOperStatus
OID 1.3.6.1.3.42.2.1.2.3.1.4
Description The current operational status of the FxPort. Possible values are:
online (1): Login may proceed.
offline (2): Login cannot proceed.
testing (3): Port is under test.
link-failure (4): Failure after online/testing.
The testing (3) indicates that no operational frames can be
passed. If fcFxPortPhysAdminStatus is offline (2) then
fcFxPortPhysOperStatus should be offline (2). If
fcFxPortPhysAdminStatus is changed to online (1), then
fcFxPortPhysOperStatus should change to 1 (online) if the
FxPort is ready to accept Fabric Login request from the attached
NxPort; it should proceed and remain in the link-failure (4) state
if and only if there is a fault that prevents it from going to the
online (1) state.
fcFxPortPhysLastChange
OID 1.3.6.1.3.42.2.1.2.3.1.5
Description The value of sysUpTime at the time the FxPort entered its
current operational status. A value of zero indicates that the
FxPort’s operational status has not changed since the agent last
restarted.
fcFxPortPhysRttov
OID 1.3.6.1.3.42.2.1.2.3.1.6
Description The Receiver_Transmitter_Timeout value of the FxPort. This is
used by the receiver logic to detect Loss of Synchronization.
fcFxlogiTable
OID 1.3.6.1.3.42.2.1.2.4
Description A table that contains one entry for each FxPort in the Fabric
Element and services parameters established from the most
recent Fabric Login, whether explicit or implicit.
fcFxlogiEntry
OID 1.3.6.1.3.42.2.1.2.4.1
Description An entry containing service parameters established from a
successful Fabric Login.
Index fcFxloginModuleIndex, fcFxloginFxPortIndex,
fcFxloginNxPortIndex
fcFxlogiModuleIndex
OID 1.3.6.1.3.42.2.1.2.4.1.1
Description Identifies the module containing the FxPort for which this entry
contains information.
fcFxlogiFxPortIndex
OID 1.3.6.1.3.42.2.1.2.4.1.2
Description Identifies the FxPort within the module. This number ranges
from 1 to the value of fcFeModulePortCapacity for the
associated module. The value remains constant for the identified
FxPort until the module is re-initialized.
fcFxlogiNxPortIndex
OID 1.3.6.1.3.42.2.1.2.4.1.3
Description The object identifies the associated NxPort in the attachment for
which the entry contains information.
fcFxPortFcphVersionAgreed
OID 1.3.6.1.3.42.2.1.2.4.1.4
Description The version of FC-PH that the FxPort has agreed to support
from the Fabric Login.
fcFxPortNxPortBbCredit
OID 1.3.6.1.3.42.2.1.2.4.1.5
Description The total number of buffers available for holding Class 1
connect-request, Class 2 or Class 3 frames to be transmitted to
the attached NxPort. It is for buffer-to-buffer flow control in the
direction from FxPort to NxPort. The buffer-to-buffer flow
control mechanism is indicated in the respective
fcFxPortBbCreditModel.
fcFxPortNxPortRxDataFieldSize
OID 1.3.6.1.3.42.2.1.2.4.1.6
Description The Receive Data Field Size of the attached NxPort. This is a
binary value that specifies the largest Data Field Size for an
FT_1 frame that can be received by the NxPort. The value is in
number of bytes and ranges from 128 to 2112 inclusive.
fcFxPortCosSuppAgreed
OID 1.3.6.1.3.42.2.1.2.4.1.7
Description Indicates that the attached NxPort has requested the FxPort for
the support of classes of services and the FxPort has granted the
request.
fcFxPortIntermixSuppAgreed
OID 1.3.6.1.3.42.2.1.2.4.1.8
Description A variable indicating that the attached NxPort has requested the
FxPort for the support of Intermix and the FxPort has granted
the request. This flag is only valid if Class 1 service is
supported. Possible values are:
yes (1): The attached NxPort has requested the FxPort
for the support of Intermix, and the FxPort has
granted the request.
no (2): The attached NxPort has not requested the
FxPort for the support of Intermix.
fcFxPortStackedConnModeAgreed
OID 1.3.6.1.3.42.2.1.2.4.1.9
Description Indicates whether the FxPort has agreed to support stacked
connect from the Fabric Login. This is only meaningful if Class
1 service has been agreed to.
fcFxPortClass2SeqDelivAgreed
OID 1.3.6.1.3.42.2.1.2.4.1.10
Description A variable indicating whether the FxPort has agreed to support
Class 2 sequential delivery from the Fabric Login. This is only
meaningful if Class 2 service has been agreed. Possible values
are:
yes (1): The FxPort has agreed to support Class 2
sequential delivery from the Fabric Login.
no (2): The FxPort has not agreed to support Class 2
sequential delivery from the Fabric Login.
fcFxPortClass3SeqDelivAgreed
OID 1.3.6.1.3.42.2.1.2.4.1.11
Description A flag indicating whether the FxPort has agreed to support Class
3 sequential delivery from the Fabric Login. This is only
meaningful if Class 3 service has been agreed. Possible values
are:
yes (1): The FxPort has agreed to support Class 3
sequential delivery from the Fabric Login.
no (2): The FxPort has not agreed to support Class 3
sequential delivery from the Fabric Login.
fcFxPortNxPortName
OID 1.3.6.1.3.42.2.1.2.4.1.12
Description The port name of the attached NxPort, if applicable. If the value
of this object is ‘0000000000000000’H, this FxPort has no
NxPort attached to it.
fcFxPortConnectedNxPort
OID 1.3.6.1.3.42.2.1.2.4.1.13
Description The address identifier of the destination FxPort with which this
FxPort is currently engaged in a either a Class 1 or loop
connection. If the value of this object is ‘000000’H, this FxPort
is not engaged in a connection.
fcFxPortBbCreditModel
OID 1.3.6.1.3.42.2.1.2.4.1.14
Description Identifies the BB_Credit model used by the FxPort. The regular
model refers to the buffer-to-buffer flow control mechanism
defined in FC-PH [1] is used between the F_Port and the
N_Port. For FL_Ports, the Alternate Buffer-to-Buffer flow
control mechanism as defined in FC-AL [4] is used between the
FL_Port and any attached NL_Ports.
Error Group
This group consists of tables that contain information about the various types of
errors detected. The management station may use the information in this group to
determine the quality of the link between the FxPort and its attached NxPort.
Implementation of this group is optional.
OID 1.3.6.1.3.42.2.1.3.1
Description A table that contains one entry for each FxPort and counters that
record the numbers of errors detected since the management
agent re-initialized.
Note: The first 6 columnar objects after the port index correspond to the counters in the
Link ErrorStatus Block.
fcFxPortErrorEntry
OID 1.3.6.1.3.42.2.1.3.1.1
Description An entry containing error counters of a FxPort.
Index fcFxPortErrorModuleIndex, fcFxPortErrorFxPortIndex
fcFxPortErrorModuleIndex
OID 1.3.6.1.3.42.2.1.3.1.1.1
Description Identifies the module containing the FxPort for which this entry
contains information.
fcFxPortErrorFxPortIndex
OID 1.3.6.1.3.42.2.1.3.1.1.2
Description Identifies the FxPort within the module. This number ranges
from 1 to the value of fcFeModulePortCapacity for the
associated module. The value remains constant for the identified
FxPort until the module is re-initialized.
fcFxPortLinkFailures
OID 1.3.6.1.3.42.2.1.3.1.1.3
Description The number of link failures detected by this FxPort.
fcFxPortSyncLosses
OID 1.3.6.1.3.42.2.1.3.1.1.4
Description The number of loss of synchronization detected by the FxPort.
fcFxPortSigLosses
OID 1.3.6.1.3.42.2.1.3.1.1.5
Description The number of loss of signal detected by the FxPort.
n
fcFxPortPrimSeqProtoErrors
OID 1.3.6.1.3.42.2.1.3.1.1.6
Description The number of primitive sequence protocol errors detected by
the FxPort.
fcFxPortInvalidTxWords
OID 1.3.6.1.3.42.2.1.3.1.1.7
Description The number of invalid transmission word detected by the
FxPort.
fcFxPortInvalidCrcs
OID 1.3.6.1.3.42.2.1.3.1.1.8
Description The number of invalid Cyclic Redundancy Checks (CRCs)
detected by this FxPort.
fcFxPortDelimiterErrors
OID 1.3.6.1.3.42.2.1.3.1.1.9
Description The number of Delimiter Errors detected by this FxPort.
fcFxPortAddressIdErrors
OID 1.3.6.1.3.42.2.1.3.1.1.10
Description The number of address identifier errors detected by this FxPort.
fcFxPortLinkResetIns
OID 1.3.6.1.3.42.2.1.3.1.1.11
Description The number of Link Reset Protocol received by this FxPort from
the attached NxPort.
fcFxPortLinkResetOuts
OID 1.3.6.1.3.42.2.1.3.1.1.12
Description The number of Link Reset Protocol issued by this FxPort to the
attached NxPort.
fcFxPortOlsIns
OID 1.3.6.1.3.42.2.1.3.1.1.13
Description The number of Offline Sequence received by this FxPort.
fcFxPortOlsOuts
OID 1.3.6.1.3.42.2.1.3.1.1.14
Description The number of Offline Sequence issued by this FxPort.
Accounting Group
HP does not support Accounting tables. This section is not applicable
Capability Group
This group consists of a table describing information about what each FxPort is
inherently capable of operating or supporting. A capability may be used as
expressed in its respective object value in the Configuration group.
Implementation of this group is optional.
OID 1.3.6.1.3.42.2.1.5.1
Description A table that contains one entry for each FxPort and the
capabilities of the port within the Fabric Element.
fcFxPortCapEntry
OID 1.3.6.1.3.42.2.1.5.1.1
Description An entry containing the capabilities of a FxPort.
Index fcFxPortCapModuleIndex, fcFxPortCapFxPortIndex
fcFxPortCapModuleIndex
OID 1.3.6.1.3.42.2.1.5.1.1.1
Description Identifies the module containing the FxPort for which this entry
contains information.
fcFxPortCapFxPortIndex
OID 1.3.6.1.3.42.2.1.5.1.1.2
Description Identifies the FxPort within the module. This number ranges
from 1 to the value of fcFeModulePortCapacity for the
associated module. The value remains constant for the identified
FxPort until the module is re-initialized.
fcFxPortCapFcphVersionHigh
OID 1.3.6.1.3.42.2.1.5.1.1.3
Description The highest or most recent version of FC-PH that the FxPort is
capable of supporting.
fcFxPortCapFcphVersionLow
OID 1.3.6.1.3.42.2.1.5.1.1.4
Description The lowest or earliest version of FC-PH that the FxPort is
capable of supporting.
fcFxPortCapBbCreditMax
OID 1.3.6.1.3.42.2.1.5.1.1.5
Description The maximum number of receive buffers available for holding
Class 1 connect-request, Class 2 or Class 3 frames from the
attached NxPort.
fcFxPortCapBbCreditMin
OID 1.3.6.1.3.42.2.1.5.1.1.6
Description The minimum number of receive buffers available for holding
Class 1 connect-request, Class 2 or Class 3 frames from the
attached NxPort.
fcFxPortCapRxDataFieldSizeMax
OID 1.3.6.1.3.42.2.1.5.1.1.7
Description The maximum size in bytes of the Data Field in a frame that the
FxPort is capable of receiving from its attached NxPort.
fcFxPortCapRxDataFieldSizeMin
OID 1.3.6.1.3.42.2.1.5.1.1.8
Description The minimum size in bytes of the Data Field in a frame that the
FxPort is capable of receiving from its attached NxPort.
fcFxPortCapCos
OID 1.3.6.1.3.42.2.1.5.1.1.9
Description A value indicating the set of Classes of Service that the FxPort is
capable of supporting.
fcFxPortCapIntermix
OID 1.3.6.1.3.42.2.1.5.1.1.10
Description A flag indicating whether the FxPort is capable of supporting
the intermixing of Class 2 and Class 3 frames during a Class 1
connection. This flag is only valid if the port is capable of
supporting Class 1 service. Possible values are:
yes (1): The FxPort is capable of supporting the
intermixing of Class 2 and Class 3 frames during
a Class 1 connection.
no (2): The FxPort is not capable of supporting the
intermixing of Class 2 and Class 3 frames during
a Class 1 connection.
fcFxPortCapStackedConnMode
OID 1.3.6.1.3.42.2.1.5.1.1.11
Description A value indicating the mode of Stacked Connect request that the
FxPort is capable of supporting.
fcFxPortCapClass2SeqDeliv
OID 1.3.6.1.3.42.2.1.5.1.1.12
Description A flag indicating whether the FxPort is capable of supporting
Class 2 Sequential Delivery. Possible values are:
yes (1): The FxPort is capable of supporting Class 2
Sequential Delivery.
no (2): The FxPort is not capable of supporting Class 2
Sequential Delivery.
fcFxPortCapClass3SeqDeliv
OID 1.3.6.1.3.42.2.1.5.1.1.13
Description A flag indicating whether the FxPort is capable of supporting
Class 3 Sequential Delivery. Possible values are:
yes (1): The FxPort is capable of supporting Class 3
Sequential Delivery.
no (2):The FxPort is not capable of supporting
Class 3 Sequential Delivery.
fcFxPortCapHoldTimeMax
OID 1.3.6.1.3.42.2.1.5.1.1.14
Description The maximum holding time (in microseconds) that the FxPort is
capable of supporting.
fcFxPortCapHoldTimeMin
OID 1.3.6.1.3.42.2.1.5.1.1.15
Description The minimum holding time (in microseconds) that the FxPort is
capable of supporting.
fcFxPortCapBaudRates
OID 1.3.6.1.3.42.2.1.5.1.1.16
Description A value indicating the set of baud rates that the FxPort is
capable of supporting. This variable has been deprecated and
may be implemented for backward compatibility.
fcFxPortCapMedia
OID 1.3.6.1.3.42.2.1.5.1.1.17
Description A value indicating the set of media that the FxPort is capable of
supporting. This variable has been deprecated and may be
implemented for backward compatibility.
Overview
The entityMIB is the MIB module for representing multiple logical entities
supported by a single SNMP agent. This MIB is supported only in Fabric OS v4.x
and is not supported in Fabric OS v3.x or Fabric OS v2.6.1.
The descriptions of each of the MIB variables in this chapter come directly from
the entityMIB itself. The notes that follow the descriptions typically pertain to
HP-specific information and are provided by HP.
The object types in entityMIB are organized into the following groupings:
■ Entity MIB Objects
■ Entity MIB Traps
■ Entity Conformance Groups
- entityLogical (1.3.6.1.2.1.47.1.2)
- entLogicalTable (1) - entityConformance (1.3.6.1.2.1.47.3)
- entLogicalEntry (1) - entityCompliances (1)
- entLogicalIndex (1) - entityCompliance (1)
- entLogicalDescr (2) - entity2Compliance (2)
- entLogicalType (3) - entityGroups (2)
- entLogicalCommunity (4) - entityPhysicalGroup (1)
- entLogicalTAddress (5) - entityLogicalGroup (2)
- entLogicalTDomain (6) - entityMappingGroup (3)
- entLogicalContextEngineID (7) - entityGeneralGroup (4)
- entLogicalContextName (8) - entityNotificationsGroup (5)
- entityPhysical2Group (6)
- entityLogical2Group (7)
Textual Conventions
PhysicalIndex
Status Current
Description An arbitrary value that uniquely identifies the physical entity.
The value should be a small positive integer; index values for
different physical entities are not necessarily contiguous.
Syntax Integer (1... 2147483647)
PhysicalClass
Status Current
SnmpEngineIdOrNone
Status Current
Description A specially formatted SnmpEngineID string for use with the
Entity MIB.
If an instance of an object with syntax SnmpEngineIdOrNone
has a non-zero length, then the object encoding and semantics
are defined by the SnmpEngineID textual convention (see
RFC 2571 [RFC2571]).
If an instance of an object with syntax SnmpEngineIdOrNone
contains a zero-length string, then no appropriate
SnmpEngineID is associated with the logical entity (that is,
SNMPv3 not supported).
Syntax OCTET STRING (SIZE(0..32)) Empty string or
SnmpEngineID
OID 1.3.6.1.2.1.47.1.1.1
Status Current
Description This table contains one row per physical entity. The table
always contains at least one row for an “overall” physical
entity.
entPhysicalEntry
OID 1.3.6.1.2.1.47.1.1.1.1
Status Current
Description Information a,t a particular physical entity.
Each entry provides objects (entPhysicalDescr,
entPhysicalVendorType, and entPhysicalClass) to help an
NMS identify and characterize the entry, and objects
(entPhysicalContainedIn and entPhysicalParentRelPos) to
help an NMS relate the particular entry to other entries in this
table.
Index entPhysicalIndex
entPhysicalIndex
OID 1.3.6.1.2.1.47.1.1.1.1.1
Status Current
entPhysicalDescr
OID 1.3.6.1.2.1.47.1.1.1.1.2
Status Current
Description A textual description of the physical entity. This object
should contain a string that identifies the manufacturer’s name
for the physical entity and should be set to a distinct value for
each version or model of the physical entity.
entPhysicalVendorType
OID 1.3.6.1.2.1.47.1.1.1.1.3
Status Current
Description An indication of the vendor-specific hardware type of the
physical entity. Note that this is different from the definition
of MIB-II sysObjectID.
An agent should set this object to an enterprise-specific
registration identifier value indicating the specific equipment
type in detail. The associated instance of entPhysicalClass
indicates the general type of hardware device.
If no vendor-specific registration identifier exists for this
physical entity, or if the value is unknown by this agent, then
the value { 0 0 } is returned.
entPhysicalContainedIn
OID 1.3.6.1.2.1.47.1.1.1.1.4
Status Current
entPhysicalClass
OID 1.3.6.1.2.1.47.1.1.1.1.5
Status Current
Description An indication of the general hardware type of the physical
entity.
An agent should set this object to the standard enumeration
value that most accurately indicates the general class of the
physical entity, or the primary class if there is more than one.
If no appropriate standard registration identifier exists for this
physical entity, then the value other(1) is returned. If the
value is unknown by this agent, then the value
unknown(2) is returned.
entPhysicalParentRelPos
OID 1.3.6.1.2.1.47.1.1.1.1.6
Status Current
entPhysicalName
OID 1.3.6.1.2.1.47.1.1.1.1.7
Status Current
Description The textual name of the physical entity. The value of this
object should be the name of the component as assigned by
the local device and should be suitable for use in commands
entered at the device’s “console.” This might be a text name,
such as “console” or a simple component number (for
example, port or module number) such as “1,” depending on
the physical component naming syntax of the device.
If there is no local name, or this object is otherwise not
applicable, then this object contains a zero-length string.
Note that the value of entPhysicalName for two physical
entities will be the same in the event that the console interface
does not distinguish between them (for example, slot-1 and
the card in slot-1).
entPhysicalHardwareRev
OID 1.3.6.1.2.1.47.1.1.1.1.8
Status Current
entPhysicalFirmwareRev
OID 1.3.6.1.2.1.47.1.1.1.1.9
Status Current
Description The vendor-specific firmware revision string for the physical
entity.
Note that if revision information is stored internally in a
non-printable (for example, binary) format, then the agent
must convert such information to a printable format, in an
implementation-specific manner.
If no specific firmware programs are associated with the
physical component, or if this information is unknown to the
agent, then this object will contain a zero-length string.
entPhysicalSoftwareRev
OID 1.3.6.1.2.1.47.1.1.1.1.10
Status Current
Description The vendor-specific software revision string for the physical
entity.
Note that if revision information is stored internally in a
non-printable (for example, binary) format, then the agent
must convert such information to a printable format, in an
implementation-specific manner.
If no specific software programs are associated with the
physical component, or if this information is unknown to the
agent, then this object will contain a zero-length string.
entPhysicalSerialNum
OID 1.3.6.1.2.1.47.1.1.1.1.11
Status Current
Description The vendor-specific serial number string for the physical
entity. The preferred value is the serial number string actually
printed on the component itself (if present).
On the first instantiation of a physical entity, the value of
entPhysicalSerialNum associated with that entity is set to the
correct vendor-assigned serial number, if this information is
available to the agent. If a serial number is unknown or
non-existent, the entPhysicalSerialNum will be set to a
zero-length string instead.
Note that implementations that can correctly identify the
serial numbers of all installed physical entities do not need to
provide write access to the entPhysicalSerialNum object.
Agents that cannot provide non-volatile storage for the
entPhysicalSerialNum strings are not required to implement
write access for this object.
Not every physical component will have a serial number, or
even need one. Physical entities for which the associated
value of the entPhysicalIsFRU object is equal to “false(2)”
(for example, the repeater ports within a repeater module), do
not need their own unique serial number. An agent does not
have to provide write access for such entities, and may return
a zero-length string.
If write access is implemented for an instance of
entPhysicalSerialNum, and a value is written into the
instance, the agent must retain the supplied value in the
entPhysicalSerialNum instance associated with the same
physical entity for as long as that entity remains instantiated.
This includes instantiations across all re-initializations/
reboots of the network management system, including those
that result in a change of the physical entity’s
entPhysicalIndex value.
entPhysicalMfgName
OID 1.3.6.1.2.1.47.1.1.1.1.12
Status Current
Description The name of the manufacturer of this physical component.
The preferred value is the manufacturer name string actually
printed on the component itself (if present).
Note that comparisons between instances of the
entPhysicalModelName, entPhysicalFirmwareRev,
entPhysicalSoftwareRev, and the entPhysicalSerialNum
objects, are meaningful only amongst entPhysicalEntries with
the same value of entPhysicalMfgName.
If the manufacturer name string associated with the physical
component is unknown to the agent, then this object will
contain a zero-length string.
entPhysicalModelName
OID 1.3.6.1.2.1.47.1.1.1.1.13
Status Current
Description The vendor-specific model name identifier string associated
with this physical component. The preferred value is the
customer-visible part number, which may be printed on the
component itself.
If the model name string associated with the physical
component is unknown to the agent, then this object will
contain a zero-length string.
entPhysicalAlias
OID 1.3.6.1.2.1.47.1.1.1.1.14
Status Current
Description This object is an alias name for the physical entity as specified
by a network manager, and provides a non-volatile handle for
the physical entity.
On the first instantiation of a physical entity, the value of
entPhysicalAlias associated with that entity is set to the
zero-length string. However, agent may set the value to a
locally unique default value, instead of a zero-length string.
If write access is implemented for an instance of
entPhysicalAlias, and a value is written into the instance, the
agent must retain the supplied value in the entPhysicalAlias
instance associated with the same physical entity for as long
as that entity remains instantiated. This includes instantiations
across all re-initializations/reboots of the network
management system, including those which result in a change
of the physical entity’s entPhysicalIndex value.
entPhysicalAssetID
OID 1.3.6.1.2.1.47.1.1.1.1.15
Status Current
entPhysicalIsFRU
OID 1.3.6.1.2.1.47.1.1.1.1.16
Status Current
Description The entPhysicalIsFRU object indicates whether this physical
entity is considered a field replaceable unit by the vendor. If
this object contains the value “true(1),” then this
entPhysicalEntry identifies a field replaceable unit. For all
entPhysicalEntries representing components that are
permanently contained within a field replaceable unit, the
value “false(2)” should be returned for this object.
OID 1.3.6.1.2.1.47.1.2.1
Description This table contains one row per logical entity. For agents that
implement more than one naming scope, at least one entry
must exist. Agents that instantiate all MIB objects within a
single naming scope are not required to implement this table.
entLogicalEntry
OID 1.3.6.1.2.1.47.1.2.1.1
Description Information a,t a particular logical entity. Entities may be
managed by this agent or other SNMP agents (possibly) in the
same chassis.
Index entLogicalIndex
entLogicalIndex
OID 1.3.6.1.2.1.47.1.2.1.1.1
Description The value of this object uniquely identifies the logical entity.
The value should be a small positive integer; index values for
different logical entities are are not necessarily contiguous.
entLogicalDescr
OID 1.3.6.1.2.1.47.1.2.1.1.2
Description A textual description of the logical entity. This object should
contain a string that identifies the manufacturer’s name for the
logical entity, and should be set to a distinct value for each
version of the logical entity.
entLogicalType
OID 1.3.6.1.2.1.47.1.2.1.1.3
entLogicalCommunity
OID 1.3.6.1.2.1.47.1.2.1.1.4
Description An SNMPv1 or SNMPv2C community-string, which can be
used to access detailed management information for this
logical entity. The agent should allow read access with this
community string (to an appropriate subset of all managed
objects) and may also return a community string based on the
privileges of the request used to read this object.
Note that an agent may return a community string with
read-only privileges, even if this object is accessed with a
read-write community string. However, the agent must take
care not to return a community string that allows more
privileges than the community string used to access this
object.
A compliant SNMP agent may wish to conserve naming
scopes by representing multiple logical entities in a single
default naming scope. This is possible when the logical
entities represented by the same value of
entLogicalCommunity have no object instances in common.
For example, “bridge1” and “repeater1” may be part of the
main naming scope, but at least one additional community
string is needed to represent “bridge2” and “repeater2.”
entLogicalTAddress
OID 1.3.6.1.2.1.47.1.2.1.1.5
Description The transport service address by which the logical entity
receives network management traffic, formatted according to
the corresponding value of entLogicalTDomain.
For snmpUDPDomain, a TAddress is 6 octets long, the initial
4 octets containing the IP-address in network-byte order and
the last 2 containing the UDP port in network-byte order.
Consult Transport Mappings for Version 2 of the Simple
Network Management Protocol (RFC 1906 [RFC1906]) for
further information on snmpUDPDomain.
entLogicalTDomain
OID 1.3.6.1.2.1.47.1.2.1.1.6
Description Indicates the kind of transport service by which the logical
entity receives network management traffic. Possible values
for this object are presently found in the Transport Mappings
for SNMPv2 document (RFC 1906 [RFC1906]).
entLogicalContextEngineID
OID 1.3.6.1.2.1.47.1.2.1.1.7
Description The authoritative contextEngineID that can be used to send an
SNMP message concerning information held by this logical
entity, to the address specified by the associated
entLogicalTAddress/entLogicalTDomain pair.
This object, together with the associated
entLogicalContextName object, defines the context associated
with a particular logical entity, and allows access to SNMP
engines identified by a contextEngineId and contextName
pair.
If no value has been configured by the agent, a zero-length
string is returned, or the agent may choose not to instantiate
this object at all.
entLogicalContextName
OID 1.3.6.1.2.1.47.1.2.1.1.8
Description The contextName that can be used to send an SNMP message
concerning information held by this logical entity, to the
address specified by the associated
entLogicalTAddress/entLogicalTDomain pair.
This object, together with the associated
entLogicalContextEngineID object, defines the context
associated with a particular logical entity, and allows access to
SNMP engines identified by a contextEngineId and
contextName pair.
If no value has been configured by the agent, a zero-length
string is returned, or the agent may choose not to instantiate
this object at all.
OID 1.3.6.1.2.1.47.1.3.1
entLPMappingEntry
OID 1.3.6.1.2.1.47.1.3.1.1
Description Information a,t a particular logical entity to physical
equipment association. Note that the nature of the association
is not specifically identified in this entry. It is expected that
sufficient information exists in the MIBs used to manage a
particular logical entity to infer how physical component
information is utilized.
Index entLogicalIndex
entLPPhysicalIndex
entLPPhysicalIndex
OID 1.3.6.1.2.1.47.1.3.1.1.1
Description The value of this object identifies the index value of a
particular entPhysicalEntry associated with the indicated
entLogicalEntity.
entAliasMappingTable
OID 1.3.6.1.2.1.47.1.3.2
Description This table contains zero or more rows, representing mappings
of logical entity and physical component to external MIB
identifiers. Each physical port in the system may be
associated with a mapping to an external identifier, which
itself is associated with a particular logical entity’s naming
scope. A wildcard mechanism is provided to indicate that an
identifier is associated with more than one logical entity.
entAliasMappingEntry
OID 1.3.6.1.2.1.47.1.3.2.1
Description Information about a particular physical equipment, logical
entity to external identifier binding. Each logical
entity/physical component pair may be associated with one
alias mapping. The logical entity index may also be used as a
wildcard (refer to the “entAliasLogicalIndexOrZero” object
description for details.)
Note that only entPhysicalIndex values that represent physical
ports (that is, associated entPhysicalClass value is “port(10)”)
are permitted to exist in this table.
Index entPhysicalIndex
entAliasLogicalIndexOrZero
entAliasLogicalIndexOrZero
OID 1.3.6.1.2.1.47.1.3.2.1.1
Description The value of this object identifies the logical entity that
defines the naming scope for the associated instance of the
entAliasMappingIdentifier object.
If this object has a non-zero value, then it identifies the logical
entity named by the same value of entLogicalIndex.
If this object has a value of zero, then the mapping between
the physical component and the alias identifier for this
entAliasMapping entry is associated with all unspecified
logical entities. That is, a value of zero (the default mapping)
identifies any logical entity that does not have an explicit
entry in this table for a particular
entPhysicalIndex/entAliasMappingIdentifier pair.
For example, to indicate that a particular interface (such as
“physical component 33”) is identified by the same value of
ifIndex for all logical entities, the following instance might
exist:
entAliasMappingIdentifier.33.0 = ifIndex.5
In the event an entPhysicalEntry is associated differently for
some logical entities, additional entAliasMapping entries may
exist, for example:
entAliasMappingIdentifier.33.0 = ifIndex.6
entAliasMappingIdentifier.33.4 = ifIndex.1
entAliasMappingIdentifier.33.5 = ifIndex.1
entAliasMappingIdentifier.33.10 = ifIndex.12
Note that entries with non-zero entAliasLogicalIndexOrZero
index values have precedence over any zero-indexed entry. In
this example, all logical entities except 4, 5, and 10 associate
physical entity 33 with ifIndex.6.
entAliasMappingIdentifier
OID 1.3.6.1.2.1.47.1.3.2.1.2
entPhysicalContainsTable
OID 1.3.6.1.2.1.47.1.3.3
Description A table that exposes the container/“containee” relationships
between physical entities. This table provides all the
information found by constructing the virtual containment
tree for a given entPhysicalTable, but in a more direct format.
In the event a physical entity is contained by more than one
other physical entity (for example, double-wide modules),
this table should include these additional mappings, which
cannot be represented in the entPhysicalTable virtual
containment tree.
entPhysicalContainsEntry
OID 1.3.6.1.2.1.47.1.3.3.1
entPhysicalChildIndex
OID 1.3.6.1.2.1.47.1.3.3.1.1
Description The value of entPhysicalIndex for the contained physical
entity.
OID 1.3.6.1.2.1.47.1.4.1
Description The value of sysUpTime at the time a conceptual row is
created, modified, or deleted in any of the following tables:
■ entPhysicalTable
■ entLogicalTable
■ entLPMappingTable
■ entAliasMappingTable
■ entPhysicalContainsTable
OID 1.3.6.1.2.1.47.2.0.1
Status Current
Description An entConfigChange notification is generated when the value
of entLastChangeTime changes. It can be utilized by an NMS
to trigger logical/physical entity table maintenance polls.
An agent should not generate more than one
entConfigChange notification-event in a given time interval
(five seconds is the suggested default). A notification-event is
the transmission of a single trap or inform PDU to a list of
notification destinations.
If additional configuration changes occur within the throttling
period, then notification-events for these changes should be
suppressed by the agent until the current throttling period
expires. At the end of a throttling period, one
notification-event should be generated if any configuration
changes occurred since the start of the throttling period. In
such a case, another throttling period is started right away.
An NMS should periodically check the value of
entLastChangeTime to detect any missed entConfigChange
notification-events, for example, due to throttling or
transmission loss.
OID 1.3.6.1.2.1.47.3.1.1
Status Deprecated
Description The compliance statement for SNMP entities that implement
version 1 of the Entity MIB.
Module This module:
MANDATORY-GROUPS {
entityPhysicalGroup,
entityLogicalGroup,
entityMappingGroup,
entityGeneralGroup,
entityNotificationsGroup
}
entity2Compliance
OID 1.3.6.1.2.1.47.3.1.2
Status Current
Description The compliance statement for SNMP entities that implement
version 2 of the Entity MIB.
Module This module:
MANDATORY-GROUPS {
entityPhysicalGroup,
entityPhysical2Group,
entityGeneralGroup,
entityNotificationsGroup
}
Group entityLogical2Group
Description Implementation of this group is not mandatory for agents that
model all MIB object instances within a single naming scope.
Group entityMappingGroup
Description Implementation of the entPhysicalContainsTable is
mandatory for all agents. Implementation of the
entLPMappingTable and entAliasMappingTables are not
mandatory for agents that model all MIB object instances
within a single naming scope.
Note that the entAliasMappingTable may be useful for all
agents, however implementation of the entityLogicalGroup or
entityLogical2Group is required to support this table.
Object entPhysicalSerialNum
Access Not-accessible
Description Read and write access is not required for agents that cannot
identify serial number information for physical entities, or
cannot provide non-volatile storage for NMS-assigned serial
numbers.
Write access is not required for agents that can identify serial
number information for physical entities, but cannot provide
non-volatile storage for NMS-assigned serial numbers.
Write access is not required for physical entities for which the
associated value of the entPhysicalIsFRU object is equal to
“false(2).”
Object entPhysicalAlias
Access Read-only
Description Write access is required only if the associated
entPhysicalClass value is equal to “chassis(3).”
Object entPhysicalAssetID
Access Not-accessible
Description Read and write access is not required for agents that cannot
provide non-volatile storage for NMS-assigned asset
identifiers.
Write access is not required for physical entities for which the
associated value of entPhysicalIsFRU is equal to “false(2).”
entityPhysicalGroup
OID 1.3.6.1.2.1.47.3.2.1
Objects entPhysicalDescr,
entPhysicalVendorType,
entPhysicalContainedIn,
entPhysicalClass,
entPhysicalParentRelPos,
entPhysicalName
Status Current
Description The collection of objects that are used to represent physical
system components, for which a single agent provides
management information.
entityLogicalGroup
OID 1.3.6.1.2.1.47.3.2.2
Objects entLogicalDescr,
entLogicalType,
entLogicalCommunity,
entLogicalTAddress,
entLogicalTDomain
Status Deprecated
Description The collection of objects that are used to represent the list of
logical entities for which a single agent provides management
information.
entityMappingGroup
OID 1.3.6.1.2.1.47.3.2.3
Objects entLPPhysicalIndex,
entAliasMappingIdentifier,
entPhysicalChildIndex
Status Current
Description The collection of objects that are used to represent the
associations between multiple logical entities, physical
components, interfaces, and port identifiers for which a single
agent provides management information.
entityGeneralGroup
OID 1.3.6.1.2.1.47.3.2.4
Objects entLastChangeTime
Status Current
Description The collection of objects that are used to represent general
entity information for which a single agent provides
management information.
entityNotificationsGroup
OID 1.3.6.1.2.1.47.3.2.5
Notifications entConfigChange
Status Current
Description The collection of notifications used to indicate Entity MIB
data consistency and general status information.
entityPhysical2Group
OID 1.3.6.1.2.1.47.3.2.6
Objects entPhysicalHardwareRev,
entPhysicalFirmwareRev,
entPhysicalSoftwareRev,
entPhysicalSerialNum,
entPhysicalMfgName,
entPhysicalModelName,
entPhysicalAlias,
entPhysicalAssetID,
entPhysicalIsFRU
Status Current
Description The collection of objects that are used to represent physical
system components, for which a single agent provides
management information. This group augments the objects
contained in the entityPhysicalGroup.
entityLogical2Group
OID 1.3.6.1.2.1.47.3.2.7
Objects entLogicalDescr,
entLogicalType,
entLogicalTAddress,
entLogicalTDomain,
entLogicalContextEngineID,
entLogicalContextName
Status Current
Description The collection of objects that are used to represent the list of
logical entities for which a single SNMP entity provides
management information.
Overview
The descriptions of the MIB variables in this chapter come directly from the FC
Switch-MIB. The notes that follow the descriptions typically pertain to
HP-specific information as provided by HP.
- swTrapsV2 (1.3.6.1.4.1.1588.2.1.1.1.0)
- swFault (1)
- swSensorScn (Obsoleted by swFabricWatchTrap) (2)
- swFCPortScn (3)
- swEventTrap (4)
- swFabricWatchTrap (5)
- swTrackChangesTrap (6)
- swSystem (1.3.6.1.4.1.1588.2.1.1.1.1)
- swCurrentDate (1)
- swBootDate (2)
- swFWLastUpdated (3)
- swFlashLastUpdated (4)
- swBootPromLastUpdated (5)
- swFirmwareVersion (6)
- swOperStatus (7)
- swAdmStatus (8)
- swTelnetShellAdmStatus (9)
- swSsn (10)
- swFlashDLOperStatus (11)
- swFlashDLAdmStatus (12)
- swFlashDLHost (13)
- swFlashDLUser (14)
- swFlashDLFile (15)
- swFlashDLPassword (16)
- swBeaconOperStatus (18)
- swBeaconAdmStatus (19)
- swDiagResult (20)
- swNumSensors (21)
- swSensorTable (22)
- swSensorEntry (1)
- swSensorIndex (1)
- swSensorType (2)
- swSensorStatus (3)
- swSensorValue (4)
- swSensorInfo (5)
- swTrackChangesInfo (23)
- swID (24)
- swEtherIPAddress (25)
- swEtherIPMask (26)
- swFCIPAddress (27)
- swFCIPMask (28)
- swFabric (1.3.6.1.4.1.1588.2.1.1.1.2)
- swDomainID (1)
- swPrincipalSwitch (2)
- swNumNbs (8)
- swNbTable (9)
- swNbEntry (1)
- swNbIndex (1)
- swNbMyPort (2)
- swNbRemDomain (3)
- swNbRemPort (4)
- swNbBaudRate (5)
- swNbIslState (6)
- swNbIslCost (7)
- swNbRemPortName (8)
- swFabricMemTable (10)
- swFabricMemEntry (1)
- swFabricMemWwn (1)
- swFabricMemDid (2)
- swFabricMemName (3)
- swFabricMemEIP (4)
- swFabricMemFCIP (5)
- swFabricMemGWIP (6)
- swFabricMemType (7)
- swFabricMemShortVersion (8)
- swModule (1.3.6.1.4.1.1588.2.1.1.1.3)
- swAgtCfg (1.3.6.1.4.1.1588.2.1.1.1.4)
- swAgtCmtyTable (11)
- swAgtCmtyEntry (1)
- swAgtCmtyIdx (1)
- swAgtCmtyStr (2)
- swAgtTrapRcp (3)
Figure 18: Tree Structure for swFCport, swNs, and swEvent groups
- swFwSystem (1.3.6.1.4.1.1588.2.1.1.1.10)
- swFwFabricWatchLicense (1)
- swFwClassAreaTable (2)
- swFwClassAreaEntry (1)
- swFwClassAreaIndex (1)
- swFwWriteThVals (2)
- swFwDefaultUnit (3)
- swFwDefaultTimebase (4)
- swFwDefaultLow (5)
- swFwDefaultHigh (6)
- swFwDefaultBufSize (7)
- swFwCustUnit (8)
- swFwCustTimebase (9)
- swFwCustLow (10)
- swFwCustHigh (11)
- swFwCustBufSize (12)
- swFwThLevel (13)
- swFwWriteActVals (14)
- swFwDefaultChangedActs (15)
- swFwDefaultExceededActs (16)
- swFwDefaultBelowActs (17)
- swFwDefaultAboveActs (18)
- swFwDefaultInBetweenActs (19)
- swFwCustChangedActs (20)
- swFwCustExceededActs (21)
- swFwCustBelowActs (22)
- swFwCustAboveActs (23)
- swFwCustInBetweenActs (24)
- swFwValidActs (25)
- swFwActLevel (26)
- swFwThresholdTable (3)
- swFwThresholdEntry (1)
- swFwThresholdIndex (1)
- swFwStatus (2)
- swFwName (3)
- swFwLabel (4)
- swFwCurVal (5)
- swFwLastEvent (6)
- swFwLastEventVal (7)
- swFwLastEventTime (8)
- swFwLastState (9)
- swFwBehaviorType (10)
- swFwBehaviorInt (11)
- swEndDevice (1.3.6.1.4.1.1588.2.1.1.1.21)
- swEndDeviceRlsTable (1)
- swEndDeviceRlsEntry (1)
- swEndDevicePort (1)
- swEndDeviceAlpa (2)
- swEndDevicePortID (3)
- swEndDeviceLinkFailure (4)
- swEndDeviceSyncLoss (5)
- swEndDeviceSigLoss (6)
- swEndDeviceProtoErr (7)
- swEndDeviceInvalidWord (8)
- swEndDeviceInvalidCRC (9)
- swGroup (1.3.6.1.4.1.1588.2.1.1.1.22)
- swGroupTable (1)
- swGroupEntry (1)
- swGroupIndex (1)
- swGroupName (2)
- swGroupType (3)
- swGroupMemTable (1)
- swGroupMemEntry (1)
- swGroupID (1)
- swGroupMemWwn (2)
- swGroupMemPos (3)
- swB-mPerfMnt (1.3.6.1.4.1.1588.2.1.1.1.23)
- swBlmPerfALPAMntTable (1)
- swBlmPerfALPAMntEntry (1)
- swBlmPerfAlpaPort (1)
- swBlmPerfAlpaIndx (2)
- swBlmPerfAlpa (3)
- swBlmPerfAlpaCRCCnt (4)
- swBlmPerfEEMntTable (2)
- swBlmPerfEEMntEntry (1)
- swBlmPerfEEPort (1)
- swBlmPerfEERefKey (2)
- swBlmPerfEECRC (3)
- swBlmPerfEEFCWRx (4)
- swBlmPerfEEFCWTx (5)
- swBlmPerfEESid (6)
- swBlmPerfEEDid (7)
- swBlmPerfFltMntTable (3)
- swBlmPerfFltMntEntry (1)
- swBlmPerfFltPort (1)
- swBlmPerfFltRefkey (2)
- swBlmPerfFltCnt (3)
- swBlmPerfFltAlias (4)
Figure 20: Tree Structure for swEndDevice, swGroup, and swBlmPerfMnt
- swTrunk (1.3.6.1.4.1.1588.2.1.1.1.24)
- swSwitchTrunkable (1)
- swTrunkTable (2)
- swTrunkEntry (1)
- swTrunkPortIndex (1)
- swTrunkGroupNumber (2)
- swTrunkMaster (3)
- swPortTrunked (4)
- swTrunkGrpTable (3)
- swTrunkGrpEntry (1)
- swTrunkGrpNumber (1)
- swTrunkGrpMaster (2)
- swTrunkGrpTx (3)
- swTrunkGrpRx (4)
sw Traps
This section contains descriptions and other information that is specific to sw Trap
types.
swFault
OID 1.3.6.1.4.1.1588.2.1.1.1.0.1
Enterprise sw
Variables swDiagResult, swSsn
Description A swFault (1) is generated whenever the diagnostics detect a
fault with the switch.
Example Diagnostics:
OID 1.3.6.1.4.1.1588.2.1.1.1.0.2
Enterprise sw
swFCPortScn
OID 1.3.6.1.4.1.1588.2.1.1.1.0.3
Enterprise sw
Variables swFCPortOpStatus, swFCPortIndex, swFCPortName, swSsn
Description A swFCPortScn (3) is generated whenever an FC_Port changes
its operational state. For instance, the FC_Port goes from online
to offline. The VarBind in the Trap Data Unit shall contain the
corresponding instance of the FC_Port's operational status,
index, swFCPortName, and swSsn. swFCPortName and swSsn
are optional.
#STATE Operational
swEventTrap
OID 1.3.6.1.4.1.1588.2.1.1.1.0.4
Enterprise sw
Variables swEventIndex, swEventTimeInfo, swEventLevel,
swEventRepeatCount, swEventDescr, swSsn
Description This trap is generated when an event occurs, with a level that is
at or below swEventTrapLevel.
swFabricWatchTrap
OID 1.3.6.1.4.1.1588.2.1.1.1.0.5
Enterprise sw
Variables “swFwClassAreaIndex” on page 246
“swFwThresholdIndex” on page 253
“swFwName” on page 254
“swFwLabel” on page 256
“swFwLastEvent” on page 256
“swFwLastEventVal” on page 256
“swFwLastEventTime” on page 256
“swFwLastState” on page 256
“swSsn” on page 215
Description Trap to be sent by Fabric Watch to notify of an event.
swTrackChangesTrap
OID 1.3.6.1.4.1.1588.2.1.1.1.0.6
Enterprise sw
Variables swTrackChangesInfo, swSsn
Description Trap to be sent for tracking login/logout/configuration
changes.
System Group
swCurrentDate
OID 1.3.6.1.4.1.1588.2.1.1.1.1.1
Description The current date and time.
swBootDate
OID 1.3.6.1.4.1.1588.2.1.1.1.1.2
Description The date and time when the system last booted.
Example:
Thu Aug 17 15:16:09 2002
swFWLastUpdated
OID 1.3.6.1.4.1.1588.2.1.1.1.1.3
Description The date and time when the firmware was last loaded to the
switch.
swFlashLastUpdated
OID 1.3.6.1.4.1.1588.2.1.1.1.1.4
Description The date and time when the firmware was last downloaded or
the configuration file was last changed.
Where:
ddd = Day
MMM = Month
DD = Date
hh = Hour
mm = Minute
ss = Seconds
yyyy = Year
Example:
Thu Aug 17 15:16:09 2000
swBootPromLastUpdated
OID 1.3.6.1.4.1.1588.2.1.1.1.1.5
Description The date and time when the BootPROM was last updated.
swFirmwareVersion
OID 1.3.6.1.4.1.1588.2.1.1.1.1.6
Description The current version of the firmware.
Note: The return value is displayed using the following format: vM.m.f
Where:
v = The deployment indicator
M = Major version
m = Minor version
f = Software maintenance version
Example:
v2.2.1 (indicating FOS version 2.2.1)
swOperStatus
OID 1.3.6.1.4.1.1588.2.1.1.1.1.7
Description The current operational status of the switch. Possible values are:
online (1): The switch is accessible by an external Fibre
Channel port.
offline (2): The switch is not accessible.
testing (3): The switch is in a built-in test mode and is not
accessible by an external Fibre Channel port.
faulty (4): The switch is not operational.
swAdmStatus
OID 1.3.6.1.4.1.1588.2.1.1.1.1.8
Description The desired administrative status of the switch. A management
station may place the switch in a desired state by setting this
object accordingly. Possible values are:
online (1): Set the switch to be accessible by an
external Fibre Channel port.
offline (2): Set the switch to be inaccessible.
testing (3): Set the switch to run the built-in test.
faulty (4): Set the switch to a “soft” faulty
condition.
reboot (5): Set the switch to reboot in 1 second.
fastboot (6): Set the switch to fastboot in 1 second.
Fastboot causes theswitch to boot but
skip over the POST.
switchReboot (7): Set the current switch to reboot in 1
second.
Note: When the switch is in faulty state, only two states can be set: faulty and
reboot/fastboot/switchReboot.
The testing (3), faulty (4), and switchReboot (7) values are not applicable with the
SAN Switch 2/32.
The switchReboot (7) value only applies to the Core Switch 2/64.
swTelnetShellAdmStatus
Note: Applicable to HP Fabric OS v2.x and v3.x only (not supported in v4.x).
OID 1.3.6.1.4.1.1588.2.1.1.1.1.9
Description The desired administrative status of the telnet shell. Possible
values are:
unknown (0): The status of the current telnet shell task is
unknown.
terminated (1):The current telnet shell task is deleted.
Note: V3.0: By setting it to 1 (terminated), the current telnet shell task is deleted. When
this variable instance is read, it reports the value last set through SNMP.
V4.0: Not Supported.
swSsn
OID 1.3.6.1.4.1.1588.2.1.1.1.1.10
Description The soft serial number of the switch.
Flash Administration
The next six objects are related to firmware or configuration file management. The
underlying method in the transfer of the firmware or configuration file is based on
either FTP or remote shell. If a password is provided, then FTP is used. If NO
password is provided, then remote shell is used.
Use one of the two following methods to manage the firmware or switch
configuration file in the switch Flash:
Method 1:
Set swFlashDLHost.0, swFlashDLUser.0, and swFlashDLFile.0 to appropriate
host IP address in user dot notation (for example, 192.168.1.7), user name (for
example, administrator), and file name of the firmware or configuration file (for
example, /home/fcswh/v2.2) respectively.
Method 2:
1. Set swFlashDLPassword.0 to an appropriate value (for example, secret) if
FTP is the desired method of transfer.
2. Set swFlashDLAdmStatus.0 to 3 (swCfUpload) or 4 (swCfDownload)
accordingly.
swFlashDLOperStatus
OID 1.3.6.1.4.1.1588.2.1.1.1.1.11
Description The operational status of the Flash. Possible values are:
unknown (0):
swCurrent (1): The Flash contains the current
firmware image or configuration file.
swFwUpgraded (2): The Flash contains the image
upgraded from the
swFlashDLHost.0.
swCfUploaded (3): The switch configuration file has
been uploaded to the host.
swCfDownloaded (4): The switch configuration file has
been downloaded from the host.
swFwCorrupted (5): The firmware in the Flash of the
switch is corrupted.
swFlashDLAdmStatus
OID 1.3.6.1.4.1.1588.2.1.1.1.1.12
Description The desired state of the Flash.
The host is specified in swFlashDLHost.0. In addition, user
name is specified in swFlashDLUser.0, and the file name
specified in swFlashDLFile.0. Possible values are:
swCurrent (1): The Flash contains the current
firmware image or configuration file.
swCfUpload (3): The switch configuration file is to be
uploaded to the host specified.
swCfDownload (4): The switch configuration file is to be
downloaded from the host specified.
swFwCorrupted (5): The firmware in the Flash is corrupted.
This value is for informational
purposes only. However, set of
swFlashDLAdmStatus to this value is
not allowed.
Note: For more information about the following commands, refer to the HP
StorageWorks Fabric OS Version 3.1.x/4.1.x Reference Guide:
■ configUpload
■ configDownload
swFlashDLHost
OID 1.3.6.1.4.1.1588.2.1.1.1.1.13
Description The name or IP address (in dot notation) of the host to download
or upload a relevant file to the Flash.
swFlashDLUser
OID 1.3.6.1.4.1.1588.2.1.1.1.1.14
Description The user name on the host that is used for downloading or
uploading a relevant file to or from the Flash.
swFlashDLFile
OID 1.3.6.1.4.1.1588.2.1.1.1.1.15
Description The name of the file to be downloaded or uploaded.
swFlashDLPassword
OID 1.3.6.1.4.1.1588.2.1.1.1.1.16
Description The password to be used for an FTP transfer of files in the
download or upload operation.
swBeaconOperStatus
OID 1.3.6.1.4.1.1588.2.1.1.1.1.18
Description The current operational status of the switch beacon. When the
beacon is on, the LEDs on the front panel of the switch run
alternately from left to right and right to left. In this state, the
color of the LED is yellow. When the beacon is off, each LED
will be in its regular status, indicating color and state. Possible
values are:
on (1): The LEDs on the front panel of the switch run
alternately from left to right and right to left. The
color is yellow.
off (2): Each LED is in its regular status, indicating color
and state.
swBeaconAdmStatus
OID 1.3.6.1.4.1.1588.2.1.1.1.1.19
Description The desired status of the switch beacon. When the beacon is set
to on, the LEDs on the front panel of the switch run alternately
from left to right and right to left. The color is yellow. When the
beacon is set to off, each LED will be in its regular status,
indicating color and state. Possible values are:
on (1): The LEDs on the front panel of the switch run
alternately from left to right and right to left. Set
the color to yellow.
off (2): Set each LED to its regular status, indicating color
and state.
swDiagResult
OID 1.3.6.1.4.1.1588.2.1.1.1.1.20
Description The result of the power-on startup (POST) diagnostics. Possible
values are:
sw-ok (1): The switch is okay.
sw-faulty (2): The switch has experienced an unknown
fault.
sw-embedded-port-fault (3): The switch has experienced
an embedded port fault.
swNumSensors
OID 1.3.6.1.4.1.1588.2.1.1.1.1.21
Description The number of sensors inside the switch.
swSensorTable
OID 1.3.6.1.4.1.1588.2.1.1.1.1.22
Description Table of sensor entries.
swSensorEntry
OID 1.3.6.1.4.1.1588.2.1.1.1.1.22.1
Description An entry of the sensor information.
Index swSensorIndex
swSensorIndex
OID 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.1
Description The index of the sensor.
swSensorType
OID 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2
Description The type of sensor.
swSensorStatus
OID 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3
Description The current status of the sensor. Possible values are:
unknown (1): The status of the sensor is unknown.
faulty (2): The status of the sensor is in a faulty state.
below-min (3): The sensor value is below the minimal
threshold.
nominal (4): The status of the sensor is in a nominal state.
above-max (5):The sensor value is above the maximum
threshold.
absent (6): The sensor is missing.
swSensorValue
OID 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4
Description The current value (reading) of the sensor.
The value, -2147483648, represents an unknown quantity.
It also means that the sensor does not have the capability to
measure the actual value. In V2.0, the temperature sensor value
will be in Celsius; the fan value will be in RPM (revolution per
minute); and the power supply sensor reading will be unknown.
Note: For Fan, the value -2147483648 indicates that the unit is missing.
For Power Supply, the return value is always -2147483648.
swSensorInfo
OID 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5
Description Additional displayable information on the sensor. It contains the
sensor type and number in textual format. For example, Temp 3
or Fan 6.
SAN Switch 2/16:
■ For swSensorIndex 1 through 5, valid return values include:
— Temp #1
— Temp #2
— Temp #3
— Temp #4
— Temp #5
■ For swSensorIndex 6 through 11, valid return values
include:
— Fan #1
— Fan #2
— Fan #3
— Fan #4
— Fan #5
— Fan #6
■ For swSensorIndex 12 and 13, valid return values include:
— Power Supply #1
— Power Supply #2
Core Switch 2/64:
■ Return values for the Core Switch 2/64 depend entirely upon
the configuration of your system.
swTrackChangesInfo
OID 1.3.6.1.4.1.1588.2.1.1.1.1.23
Description Track changes string. For trap only.
Note: If there are no events to track, the default return value is “No event so far.”
If there are events to track, the following are valid return values:
■ Successful login
■ Unsuccessful login
■ Logout
■ Configuration file change from task [name of task]
■ Track-changes on
■ Track-changes off
swID
OID 1.3.6.1.4.1.1588.2.1.1.1.1.24
Description The number of the logical switch (either 0 or 1).
swEtherIPAddress
OID 1.3.6.1.4.1.1588.2.1.1.1.1.25
Description The IP address of the Ethernet interface of this logical switch.
swEtherIPMask
OID 1.3.6.1.4.1.1588.2.1.1.1.1.26
Description The IP Mask of the Ethernet interface of this logical switch.
swFCIPAddress
OID 1.3.6.1.4.1.1588.2.1.1.1.1.27
Description The IP address of the FC interface of this logical switch.
swFCIPMask
OID 1.3.6.1.4.1.1588.2.1.1.1.1.28
Description The IP Mask of the FC interface of this logical switch.
Fabric Group
swDomainID
OID 1.3.6.1.4.1.1588.2.1.1.1.2.1
Description The current Fibre Channel domain ID of the switch. To set a
new value, the switch (swAdmStatus) must be in offline or
testing state.
swPrincipalSwitch
OID 1.3.6.1.4.1.1588.2.1.1.1.2.2
Description Indicates whether the switch is the Principal switch as per
FC-SW. Possible values are:
yes (1): This is the principal switch for FC-SW.
no (2): This is not the principal switch for FC-SW.
swNumNbs
OID 1.3.6.1.4.1.1588.2.1.1.1.2.8
Description The number of Inter-Switch Links in the (immediate)
neighborhood.
swNbTable
OID 1.3.6.1.4.1.1588.2.1.1.1.2.9
Description This table contains the ISLs in the immediate neighborhood of
the switch.
swNbEntry
OID 1.3.6.1.4.1.1588.2.1.1.1.2.9.1
Description An entry containing each neighbor ISL parameters.
Index swNbIndex
swNbIndex
OID 1.3.6.1.4.1.1588.2.1.1.1.2.9.1.1
Description The neighborhood ISL entry.
swNbMyPort
OID 1.3.6.1.4.1.1588.2.1.1.1.2.9.1.2
Description This is the port that has an ISL to another switch.
Note: This value is the same as the physical port number of the local switch +1.
swNbRemDomain
OID 1.3.6.1.4.1.1588.2.1.1.1.2.9.1.3
Description This is the Fibre Channel domain on the other end of the ISL.
Note: This is the domain ID of the remote switch.Valid values are 1 through 239 as
defined by FCS-SW.
swNbRemPort
OID 1.3.6.1.4.1.1588.2.1.1.1.2.9.1.4
Description This is the port index on the other end of the ISL.
Note: The physical port number of the remote switch, plus one.
The valid values for HP switch:
Core Switch 2/64: 0 through maximum number of ports.
swNbBaudRate
OID 1.3.6.1.4.1.1588.2.1.1.1.2.9.1.5
Description The baud rate of the ISL. Possible values are:
other (1): None of the following.
oneEighth (2): 155 Mbaud.
quarter (4): 266 Mbaud.
half (8): 532 Mbaud.
full (16): 1 Gbaud.
double (32): 2 Gbaud.
quadruple (64): 4 Gbaud.
swNbIslState
OID 1.3.6.1.4.1.1588.2.1.1.1.2.9.1.6
Description The current state of the ISL.
swNbIslCost
OID 1.3.6.1.4.1.1588.2.1.1.1.2.9.1.7
Description The current link cost of the ISL. In other words, the cost of a
link to control the routing algorithm.
swNbRemPortName
OID 1.3.6.1.4.1.1588.2.1.1.1.2.9.1.8
Description The WWN of the remote port.
swFabricMemTable
OID 1.3.6.1.4.1.1588.2.1.1.1.2.10
Description This table contains information on the member switches of a
fabric. This may not be available on all versions of Fabric OS.
swFabricMemEntry
OID 1.3.6.1.4.1.1588.2.1.1.1.2.10.1
Description An entry containing each switch in the fabric.
Index swFabricMemWwn
swFabricMemWwn
OID 1.3.6.1.4.1.1588.2.1.1.1.2.10.1.1
Description This object identifies the WWN of the member switch.
swFabricMemDid
OID 1.3.6.1.4.1.1588.2.1.1.1.2.10.1.2
Description This object identifies the domain ID of the member switch.
swFabricMemName
OID 1.3.6.1.4.1.1588.2.1.1.1.2.10.1.3
Description This object identifies the name of the member switch.
swFabricMemEIP
OID 1.3.6.1.4.1.1588.2.1.1.1.2.10.1.4
Description This object identifies the Ethernet IP address of the member
switch.
swFabricMemFCIP
OID 1.3.6.1.4.1.1588.2.1.1.1.2.10.1.5
Description This object identifies the Fibre Channel IP address of the
member switch.
swFabricMemGWIP
OID 1.3.6.1.4.1.1588.2.1.1.1.2.10.1.6
Description This object identifies the Gateway IP address of the member
switch.
swFabricMemType
OID 1.3.6.1.4.1.1588.2.1.1.1.2.10.1.7
Description This object identifies the member switch type.
swFabricMemShortVersion
OID 1.3.6.1.4.1.1588.2.1.1.1.2.10.1.8
Description This object identifies the Fabric OS version of the member
switch.
OID 1.3.6.1.4.1.1588.2.1.1.1.4.11
Description A table that contains one entry for each Community and the
access control and parameters of the Community.
swAgtCmtyEntry
OID 1.3.6.1.4.1.1588.2.1.1.1.4.11.1
Description An entry containing the Community parameters.
Index swAgtCmtyIdx
swAgtCmtyIdx
OID 1.3.6.1.4.1.1588.2.1.1.1.4.11.1.1
Description The SNMPv1 Community entry.
swAgtCmtyStr
OID 1.3.6.1.4.1.1588.2.1.1.1.4.11.1.2
Description This is a Community string supported by the agent. If a new
value is set successfully, it takes effect immediately.
swAgtTrapRcp
OID 1.3.6.1.4.1.1588.2.1.1.1.4.11.1.3
Description This is the trap recipient associated with the Community. If a
new value is set successfully, it takes effect immediately.
Note: If not otherwise set, the default IP address for this trap recipient is 0.0.0.0, and
the SNMP trap is not sent for the associated community string.
For a setting of non-0.0.0.0 IP address, SNMP traps are sent to the host with the
associated community string.
Any or all of the trap recipients can be configured to send a trap for the associated
community string. The maximum number of trap recipients that can be configured is 6.
If no trap recipient is configured, no traps are sent.
The trap recipient IP address should be part of the Access Control List for Fabric OS
v2.6.1, v3.1, and v4.x (see the agtCfgSet command).
OID 1.3.6.1.4.1.1588.2.1.1.1.6.1
Description The maximum number of Fibre Channel ports on this switch. It
includes U_Port, F_Port, FL_Port and any other types of Fibre
Channel port.
Note: The valid values for Core Switch 2/64 switch vary, according to the
configuration of the switch. For example, one of the values could be 64.
swFCPortTable
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2
Description A table that contains one entry for each switch port and
configuration and service parameters of the port.
swFCPortEntry
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1
Description An entry containing the configuration and service parameters of
the switch port.
Index swFCPortIndex
swFCPortIndex
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.1
Description The switch port index.
Note: The physical port number of the switch, plus one. The valid value for HP switch:
Core Switch 2/64: 0 through maximum number of ports.
swFCPortType
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.2
Description The type of ASIC for the switch port. Possible values are:
stitch (1)
flannel (2)
loom (3): (StorageWorks 1 Gb SAN switches)
bloom (4): (StorageWorks 2 Gb SAN switches)
rdbloom (5)
wormhole (6)
swFCPortPhyState
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.3
Description The physical state of the port. Possible values are:
noCard (1): No card is present in this switch slot.
noTransceiver (2): No Transceiver module in this port
(Transceiver is the generic name for
GBIC, SFP, etc.).
laserFault (3): The module is signaling a laser fault
(defective GBIC).
noLight (4): The module is not receiving light.
noSync (5): The module is receiving light but is out
of sync.
inSync (6): The module is receiving light and is in
sync.
portFault (7): The port is marked faulty (defective
GBIC, cable, or device).
diagFault (8): The port failed diagnostics (defective
G_Port or FL_Port card or motherboard.
lockRef (9): Port is locking to the reference signal.
swFCPortOpStatus
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.4
Description The operational status of the port. Possible values are:
unknown (0): The port module is physically absent.
online (1): User frames can be passed.
offline (2): No user frames can be passed.
testing (3): No user frames can be passed.
faulty (4): The port module is physically faulty.
swFCPortAdmStatus
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.5
Description The desired state of the port. A management station may place
the port in a desired state by setting this object accordingly.
Possible values are:
online (1): User frames can be passed.
offline (2): No user frames can be passed.
testing (3): No user frames can be passed.
faulty (4): No user frames can be passed.
v3.x:
The 3 (testing) state indicates that no user frames can be
passed. As the result of either explicit management action or
per configuration information accessible by the switch,
swFCPortAdmStatus is then changed to either the 1 (online)
or 3 (testing) states, or remains in the 2 (offline) state.
v4.x:
The 3 (testing) state is not supported.
swFCPortLinkState
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.6
Description Indicates the link state of the port.
enabled (1): The port is allowed to participate in the
FC-PH protocol with its attached port (or
ports if it is in an FC-AL loop).
disabled (2): The port is not allowed to participate in the
FC-PH protocol with its attached ports.
loopback (3): The port may transmit frames through an
internal path to verify the health of the
transmitter and receiver path.
Note: When the port's link state changes, its operational status (swFCPortOpStatus) is
affected.
swFCPortTxType
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.7
Description Indicates the media transmitter type of the port. Possible values
are:
unknown (1): Cannot determine the port driver.
lw (2): Long wave laser.
sw (3): Short wave laser.
ld (4): Long wave LED.
cu (5): Copper (electrical).
swFCPortTxWords
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.11
Description Counts the number of Fibre Channel words that the port has
transmitted.
swFCPortRxWords
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.12
Description Counts the number of Fibre Channel words that the port has
received.
swFCPortTxFrames
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.13
Description Counts the number of Fibre Channel frames that the port has
transmitted.
swFCPortRxFrames
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.14
Description Counts the number of Fibre Channel frames that the port has
received.
swFCPortRxC2Frames
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.15
Description Counts the number of Class 2 frames that the port has received.
swFCPortRxC3Frames
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.16
Description Counts the number of Class 3 frames that the port has received.
swFCPortRxLCs
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.17
Description Counts the number of Link Control frames that the port has
received.
swFCPortRxMcasts
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.18
Description Counts the number of Multicast frames that the port has
received.
swFCPortTooManyRdys
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.19
Description Counts the number of times when RDYs exceeds the frames
received.
swFCPortNoTxCredits
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.20
Description Counts the number of times when the transmit credit has
reached zero.
swFCPortRxEncInFrs
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.21
Description Counts the number of encoding error or disparity error inside
frames received.
swFCPortRxCrcs
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.22
Description Counts the number of CRC errors detected for frames received.
swFCPortRxTruncs
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.23
Description Counts the number of truncated frames that the port has
received.
swFCPortRxTooLongs
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.24
Description Counts the number of received frames that are too long.
swFCPortRxBadEofs
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.25
Description Counts the number of received frames that have bad EOF
delimiter.
swFCPortRxEncOutFrs
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.26
Description Counts the number of encoding error or disparity error outside
frames received.
swFCPortRxBadOs
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.27
Description Counts the number of invalid Ordered Sets received.
swFCPortC3Discards
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.28
Description Counts the number of Class 3 frames that the port has discarded.
swFCPortMcastTimedOuts
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.29
Description Counts the number of multicast frames that has been timed out.
swFCPortTxMcasts
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.30
Description Counts the number of multicast frames that has been
transmitted.
swFCPortLipIns
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.31
Description Counts the number of loop initializations that has been initiated
by loop devices attached.
swFCPortLipOuts
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.32
Description Counts the number of loop initializations that has been initiated
by the port.
swFCPortLipLastAllpa
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.33
Description Indicates the Physical Address (AL_PA) of the loop device that
initiated the last Loop Initialization.
swFCPortWwn
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.34
Description The WWN of the Fibre Channel port. The contents of an
instance are in the IEEE extended format as specified in FC-PH.
swFCPortSpeed
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.35
Description The desired baud rate for the port.
The default baud rate is 1GB or 2GB.
swFCPortName
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.36
Description A string that indicates the name of the addressed port.
The names should be persistent across switch reboots. Port
names do not have to be unique within a switch or within a
fabric.
OID 1.3.6.1.4.1.1588.2.1.1.1.7.1
Description The number of local Name Server entries.
swNsLocalTable
OID 1.3.6.1.4.1.1588.2.1.1.1.7.2
Description The table of local Name Server entries.
swNsLocalEntry
OID 1.3.6.1.4.1.1588.2.1.1.1.7.2.1
Description An entry from the local Name Server database.
Index swNsEntryIndex
swNsEntryIndex
OID 1.3.6.1.4.1.1588.2.1.1.1.7.2.1.1
Description The index of the Name Server database entry.
swNsPortID
OID 1.3.6.1.4.1.1588.2.1.1.1.7.2.1.2
Description The Fibre Channel port address ID of the entry.
swNsPortType
OID 1.3.6.1.4.1.1588.2.1.1.1.7.2.1.3
Description The type of port for this entry. Possible values are:
unknown (0): The type is defined in FC-GS-2.
nPort (1): The type is defined in FC-GS-2.
nlPort (2): The type is defined in FC-GS-2.
swNsPortName
OID 1.3.6.1.4.1.1588.2.1.1.1.7.2.1.4
Description The Fibre Channel WWN of the port entry.
swNsPortSymb
OID 1.3.6.1.4.1.1588.2.1.1.1.7.2.1.5
Description The contents of a Symbolic Name of the port entry. In FC-GS-2,
a Symbolic Name consists of a byte array of 1 through 256
bytes, and the first byte of the array specifies the length of its
contents. This object variable corresponds to the contents of the
Symbolic Name, with the first byte removed.
swNsNodeName
OID 1.3.6.1.4.1.1588.2.1.1.1.7.2.1.6
Description The Fibre Channel WWN of the associated node as defined in
FC-GS-2.
swNsNodeSymb
OID 1.3.6.1.4.1.1588.2.1.1.1.7.2.1.7
Description The contents of a Symbolic Name of the node associated with
the entry. In FC-GS-2, a Symbolic Name consists of a byte array
of 1 through 256 bytes, and the first byte of the array specifies
the length of its contents. This object variable corresponds to the
contents of the Symbolic Name, with the first byte removed.
swNsIPA
OID 1.3.6.1.4.1.1588.2.1.1.1.7.2.1.8
Description The Initial Process Associators of the node for the entry as
defined in FC-GS-2.
swNsIpAddress
OID 1.3.6.1.4.1.1588.2.1.1.1.7.2.1.9
Description The IP address of the node for the entry as defined in FC-GS-2.
The format of the address is in IPv6.
swNsCos
OID 1.3.6.1.4.1.1588.2.1.1.1.7.2.1.10
Description The class of services supported by the port.
swNsFc4
OID 1.3.6.1.4.1.1588.2.1.1.1.7.2.1.11
Description The FC-4s supported by the port as defined in FC-GS-2.
swNsIpNxPort
OID 1.3.6.1.4.1.1588.2.1.1.1.7.2.1.12
Description The object identifies IpAddress of the Nx_port for the entry.
swNsWwn
OID 1.3.6.1.4.1.1588.2.1.1.1.7.2.1.13
Description The object identifies the World Wide Name (WWN) of the
Fx_port for the entry.
swNsHardAddr
OID 1.3.6.1.4.1.1588.2.1.1.1.7.2.1.14
Description The object identifies the 24-bit hard address of the node for the
entry.
Event Group
Note: Logically, the swEventTable is separate from the error log since it is essentially a
view of the error log within a particular time window. The value of swEventIndex
indicates the number of events that have occurred since the switch booted. The values
range from 1 through 2147383647 (231 - 1).
swEventTrapLevel
OID 1.3.6.1.4.1.1588.2.1.1.1.8.1
Description Specifies the swEventTrap level in conjunction with an event's
severity level. When an event occurs, if its severity level is at or
below the specified numeric value, the agent sends the
associated swEventTrap to the configured recipients. Possible
values are:
none (0)
critical (1)
error (2)
warning (3)
informational (4)
debug (5)
Example:
If this variable is set to 3 (warning), all error logs of severity 1
(critical), 2 (error), and 3 (warning) are sent as an SNMP Trap of
swEventTrap as shown in “swEventTrap” on page 208.
swEventNumEntries
OID 1.3.6.1.4.1.1588.2.1.1.1.8.4
Description The number of entries in the Event Table. Valid values are 0
through 255
See the note on page 243.
swEventTable
OID 1.3.6.1.4.1.1588.2.1.1.1.8.5
Description The table of event entries.
swEventEntry
OID 1.3.6.1.4.1.1588.2.1.1.1.8.5.1
Description An entry of the event table.
Index swEventIndex
swEventIndex
OID 1.3.6.1.4.1.1588.2.1.1.1.8.5.1.1
Description The index of the event entry.
See the note at the top of page 243.
Note: For Fabric OS v3.x and v2.6.x, the maximum number of events is 64
swEventTimeInfo
OID 1.3.6.1.4.1.1588.2.1.1.1.8.5.1.2
Description The date and time when this event occurred.
The return string is displayed using the following format:
MMM DD hh:mm:ss
Where:
MMM = Month
DD = Date
hh = Hour
mm = Minute
ss = Seconds
Example: (HP Fabric OS v3.0 only)
Aug 17 15:16:09.
swEventLevel
OID 1.3.6.1.4.1.1588.2.1.1.1.8.5.1.3
Description The severity level of this event entry.
swEventRepeatCount
OID 1.3.6.1.4.1.1588.2.1.1.1.8.5.1.4
Description If the most recent event is the same as the previous, this number
increments by one and is the count of consecutive times this
particular event has occurred.
swEventDescr
OID 1.3.6.1.4.1.1588.2.1.1.1.8.5.1.5
Description A textual description of the event.
The return string is displayed using the following format:
taskId (taskname) errorname description
Where:
taskId = FOS taskId in hex.
taskname = FOS taskname that generated this event.
errorname = category-subcategory (for example,
SYS-BOOT)
description = Textual description of the event.
Example:
0x10fb7670 (tSwitch) SYS-BOOT Restart reason: Reboot
For more information on error messages, refer to the HP
StorageWorks Fabric OS Version 3.1.x/4.1.x Reference Guide,
Appendix A.
OID 1.3.6.1.4.1.1588.2.1.1.1.10.1
Description If the license key is installed on the switch for the Fabric Watch,
the return value is swFwLicensed. Otherwise the value is
swFwNotLicensed.
swFwClassAreaTable
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2
Description The table of classes and areas.
swFwClassAreaEntry
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1
Description An entry of the classes and areas.
Index swFwClassAreaIndex
swFwClassAreaIndex
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.1
Description This index represents the Fabric Watch classArea combination.
swFwWriteThVals
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.2
Description This applies or cancels the configuration value changes.
swFwDefaultUnit
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.3
Description A default unit string name, used to identify the unit of measure
for a Fabric Watch classArea combination.
Example:
■ C = environment (class), temperature (area).
■ RPM = environment (class), fan (area).
swFwDefaultTimebase
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.4
Description A default polling period for the Fabric Watch classArea
combination.
Example:
■ swFwTbMin = port (class), link loss (area).
■ swFwTbNone = environment (class), temperature (area).
swFwDefaultLow
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.5
Description A default low threshold value.
swFwDefaultHigh
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.6
Description A default high threshold value.
swFwDefaultBufSize
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.7
Description A default buffer size value.
swFwCustUnit
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.8
Description A customizable unit string name, used to identify the unit of
measure for a Fabric Watch classArea combination.
Example:
■ C = environment (class), temperature (area).
■ RPM = environment (class), fan (area).
swFwCustTimebase
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.9
Description A customizable polling period for the Fabric Watch classArea
combination. For example:
■ swFwTbMin = port (class), link loss (area).
■ swFwTbNone = environment (class), temperature (area).
swFwCustLow
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.10
Description A customizable, low-threshold value for a Fabric Watch
ClassArea combination.
swFwCustHigh
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.11
Description A customizable, high-threshold value for a Fabric Watch
ClassArea combination.
swFwCustBufSize
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.12
Description A customizable, buffer-size value for a Fabric Watch ClassArea
combination.
swFwThLevel
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.13
Description swFwThLevel is used to point to the current level for classArea
values. It is either default or custom.
swFwWriteActVals
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.14
Description This applies or cancels the alarm value changes.
swFwDefaultChangedActs
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.15
Description Default action matrix for changed event.
swFwDefaultExceededActs
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.16
Description Default action matrix for an exceeded event. The exceeded value
may be either above the high-threshold or below the
low-threshold.
swFwDefaultBelowActs
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.17
Description Default action matrix for below event.
swFwDefaultAboveActs
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.18
Description Default action matrix for above event.
swFwDefaultInBetweenActs
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.19
Description Default action matrix for in-between event.
swFwCustChangedActs
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.20
Description Custom action matrix for changed event.
swFwCustExceededActs
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.21
Description Custom action matrix for an exceeded event.
swFwCustBelowActs
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.22
Description Custom action matrix for below event.
swFwCustAboveActs
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.23
Description Custom action matrix for above event.
swFwCustInBetweenActs
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.24
Description Custom action matrix for in-between event.
swFwValidActs
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.25
Description Matrix of valid acts for an ClassArea.
swFwActLevel
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.26
Description swFwActLevel is used to point to the current level for classArea
values. It is either default or custom
swFwThresholdTable
OID 1.3.6.1.4.1.1588.2.1.1.1.10.3
Description The table of individual thresholds.
swFwThresholdEntry
OID 1.3.6.1.4.1.1588.2.1.1.1.10.3.1
Description An entry of an individual threshold.
Index swFwClassAreaIndex, swFwThresholdIndex
swFwThresholdIndex
OID 1.3.6.1.4.1.1588.2.1.1.1.10.3.1.1
Description Represents the element index of a threshold.
Note: For environment class, the indexes are from 2 through number of environment
sensors+1. For example, the indexes for environment class temperature area are:
■ envTemp001: index of 2
■ envTemp002: index of 3
■ envTemp003: index of 4
■ envTemp004: index of 5
■ envTemp005: index of 6
For port-related classes such as E_Port, the indexes are from 1 through number of ports.
For example, the indexes for E_Port classlink loss area:
■ eportLink000: index of 1
■ eportLink001: index of 2
■ eportLink002: index of 3
■ eportLink003: index of 4
■ eportLink004: index of 5
■ eportLink005: index of 6
■ eportLink006: index of 7
■ eportLink007: index of 8
■ eportLink008: index of 9
■ eportLink009: index of 10
■ eportLink010: index of 11
■ eportLink011: index of 12
■ eportLink012: index of 13
■ eportLink013: index of 14
■ eportLink014: index of 15
■ eportLink015: index of 16
swFwStatus
OID 1.3.6.1.4.1.1588.2.1.1.1.10.3.1.2
Description Indicates whether a threshold is enabled or disabled.
swFwName
OID 1.3.6.1.4.1.1588.2.1.1.1.10.3.1.3
Description Name of the threshold. For examples, see Table 9.
swFwLabel
OID 1.3.6.1.4.1.1588.2.1.1.1.10.3.1.4
Description Label of the threshold.
swFwCurVal
OID 1.3.6.1.4.1.1588.2.1.1.1.10.3.1.5
Description Current counter of the threshold.
swFwLastEvent
OID 1.3.6.1.4.1.1588.2.1.1.1.10.3.1.6
Description Last event type of the threshold.
swFwLastEventVal
OID 1.3.6.1.4.1.1588.2.1.1.1.10.3.1.7
Description Last event value of the threshold.
swFwLastEventTime
OID 1.3.6.1.4.1.1588.2.1.1.1.10.3.1.8
Description Last event time of the threshold.
swFwLastState
OID 1.3.6.1.4.1.1588.2.1.1.1.10.3.1.9
Description Last event state of the threshold.
swFwBehaviorType
OID 1.3.6.1.4.1.1588.2.1.1.1.10.3.1.10
Description A behavior of which the thresholds generate event.
swFwBehaviorInt
OID 1.3.6.1.4.1.1588.2.1.1.1.10.3.1.11
Description A integer of which the thresholds generate continuous event.
OID 1.3.6.1.4.1.1588.2.1.1.1.21.1
Description The table of rls for individual end devices.
swEndDeviceRlsEntry
OID 1.3.6.1.4.1.1588.2.1.1.1.21.1.1
Description An entry of an individual end devices' rls.
Index swEndDevicePort, swEndDeviceAlpa
Note: Since StorageWorks SAN switch family switches start with port # 0, the SNMP
port # should be physical port # + 1. In turn, that means that SNMP port # 3 translates
to port # 2.
swEndDevicePort
OID 1.3.6.1.4.1.1588.2.1.1.1.21.1.1.1
Description This object represents the port of the local switch to which the
end device is connected.
swEndDeviceAlpa
OID 1.3.6.1.4.1.1588.2.1.1.1.21.1.1.2
Description This object represents the ALPA of the end device. SNMP
ALPA number should be the logical ALPA number + 1. For
example, SNMP ALPA number 0xf0 translates to 0xef.
swEndDevicePortID
OID 1.3.6.1.4.1.1588.2.1.1.1.21.1.1.3
Description The Fibre Channel port address ID of the entry.
swEndDeviceLinkFailure
OID 1.3.6.1.4.1.1588.2.1.1.1.21.1.1.4
Description Link failure count for the end device.
swEndDeviceSyncLoss
OID 1.3.6.1.4.1.1588.2.1.1.1.21.1.1.5
Description Sync loss count for the end device.
swEndDeviceSigLoss
OID 1.3.6.1.4.1.1588.2.1.1.1.21.1.1.6
Description Sig loss count for the end device.
swEndDeviceProtoErr
OID 1.3.6.1.4.1.1588.2.1.1.1.21.1.1.7
Description Protocol err count for the end device.
swEndDeviceInvalidWord
OID 1.3.6.1.4.1.1588.2.1.1.1.21.1.1.8
Description Invalid word count for the end device.
swEndDeviceInvalidCRC
OID 1.3.6.1.4.1.1588.2.1.1.1.21.1.1.9
Description Invalid CRC count for the end device.
All Groups
swGroupTable
OID 1.3.6.1.4.1.1588.2.1.1.1.22.1
Description The table of groups. This may not be available on all versions of
Fabric OS.
swGroupEntry
OID 1.3.6.1.4.1.1588.2.1.1.1.22.1.1
Description An entry of table of groups.
Index swGroupIndex
swGroupIndex
OID 1.3.6.1.4.1.1588.2.1.1.1.22.1.1.1
Description This object is the group index starting from 1.
swGroupName
OID 1.3.6.1.4.1.1588.2.1.1.1.22.1.1.2
Description This object identifies the name of the group.
swGroupType
OID 1.3.6.1.4.1.1588.2.1.1.1.22.1.1.3
Description This object identifies the type of the group.
swGroupMemTable
OID 1.3.6.1.4.1.1588.2.1.1.1.22.2
Description The table of members of all groups. This may not be available
on all versions of the Fabric OS.
swGroupMemEntry
OID 1.3.6.1.4.1.1588.2.1.1.1.22.2.1
Description An entry for a member of a group.
Index swGroupID, swGroupMemWwn
swGroupID
OID 1.3.6.1.4.1.1588.2.1.1.1.22.2.1.1
Description This object identifies the Group Id of the member switch.
swGroupMemWwn
OID 1.3.6.1.4.1.1588.2.1.1.1.22.2.1.2
Description This object identifies the WWN of the member switch.
swGroupMemPos
OID 1.3.6.1.4.1.1588.2.1.1.1.22.2.1.3
Description This object identifies the position of the member switch in the
group. This is based on the order that the switches were added in
the group.
OID 1.3.6.1.4.1.1588.2.1.1.1.23.1
Description ALPA monitoring counter Table.
swBlmPerfALPAMntEntry
OID 1.3.6.1.4.1.1588.2.1.1.1.23.1.1
Description ALPA monitoring counter for given ALPA.
Index swEndDevicePort, swEndDeviceAlpa
swBlmPerfAlpaPort
OID 1.3.6.1.4.1.1588.2.1.1.1.23.1.1.1
Description This Object identifies the port index of the switch.
swBlmPerfAlpaIndx
OID 1.3.6.1.4.1.1588.2.1.1.1.23.1.1.2
Description This Object identifies the AL-PA index. There can be 126 ALPA
values.
swBlmPerfAlpa
OID 1.3.6.1.4.1.1588.2.1.1.1.23.1.1.3
Description This Object identifies the ALPA values.These values range
between x'01' and x'EF'(1 to 239). AL-PA value x'00' is reserved
for FL_Port If Alpha device is invalid, then it will have -1 value.
swBlmPerfAlpaCRCCnt
OID 1.3.6.1.4.1.1588.2.1.1.1.23.1.1.4
Description Get CRC count for given AL-PA and port. This monitoring
provides information on the number of CRC errors occurred on
the frames destined to each possible AL-PA attached to a
specific port.
swBlmPerfEEMntTable
OID 1.3.6.1.4.1.1588.2.1.1.1.23.2
Description End-to-end monitoring counter table.
swBlmPerfEEMntEntry
OID 1.3.6.1.4.1.1588.2.1.1.1.23.2.1
Description End-to-end monitoring counter for given port.
Index swBlmPerfEEPort, swBlmPerfEERefKey
swBlmPerfEEPort
OID 1.3.6.1.4.1.1588.2.1.1.1.23.2.1.1
Description This object identifies the port number of the switch.
swBlmPerfEERefKey
OID 1.3.6.1.4.1.1588.2.1.1.1.23.2.1.2
Description This object identifies the reference number of the counter. This
reference is number assigned when a filter is created. In SNMP
Index start one instead of zero, add one to the actual ref key.
swBlmPerfEECRC
OID 1.3.6.1.4.1.1588.2.1.1.1.23.2.1.3
Description End-to-end CRC error for the frames that matched the SID-DID
pair.
swBlmPerfEEFCWRx
OID 1.3.6.1.4.1.1588.2.1.1.1.23.2.1.4
Description Get end-to-end count of Fibre Channel words (FCW), received
by the port, that matched the SID-DID pair.
swBlmPerfEEFCWTx
OID 1.3.6.1.4.1.1588.2.1.1.1.23.2.1.5
Description Get end-to-end count of Fibre Channel words (FCW),
transmitted by the port, that matched the SID-DID pair.
swBlmPerfEESid
OID 1.3.6.1.4.1.1588.2.1.1.1.23.2.1.6
Description Gets DID info by reference number.
swBlmPerfEEDid
OID 1.3.6.1.4.1.1588.2.1.1.1.23.2.1.7
Description Gets Source Identifier (SID) info by reference number. SID is a
3-byte field in the frame header used to indicate the address
identifier of the N-Port from which the frame was sent.
swBlmPerfFltMntTable
OID 1.3.6.1.4.1.1588.2.1.1.1.23.3
Description Filter based monitoring counter.
swBlmPerfFltMntEntry
OID 1.3.6.1.4.1.1588.2.1.1.1.23.3.1
Description Filter base monitoring counter for given port.
Index swBlmPerfFltPort, swBlmPerfFltRefkey
swBlmPerfFltPort
OID 1.3.6.1.4.1.1588.2.1.1.1.23.3.1.1
Description This object identifies the port number of the switch.
swBlmPerfFltRefkey
OID 1.3.6.1.4.1.1588.2.1.1.1.23.3.1.2
Description This object identifies the reference number of the filter. This
reference number is assigned when a filter is created. In SNMP
Index, start one instead of 0 and add one to actual ref key.
swBlmPerfFltCnt
OID 1.3.6.1.4.1.1588.2.1.1.1.23.3.1.3
Description Get statistics of filter based monitor. Filter based monitoring
provides information about a filter hit count such as:
■ Read command
■ SCSI or IP traffic
■ SCSI Read/Write.
swBlmPerfFltAlias
OID 1.3.6.1.4.1.1588.2.1.1.1.23.3.1.4
Description Alias name for the filter.
Trunking Group
swSwitchTrunkable
OID 1.3.6.1.4.1.1588.2.1.1.1.24.1
Description The trunking status of the switch—whether the switch supports
the trunking feature or not. Possible values are:
No (0)
Yes (8)
swTrunkTable
OID 1.3.6.1.4.1.1588.2.1.1.1.24.2
Description Table to display trunking information for the switch.
swTrunkEntry
OID 1.3.6.1.4.1.1588.2.1.1.1.24.2.1
Description Entry for the trunking table.
Index swTrunkPortIndex
swTrunkPortIndex
OID 1.3.6.1.4.1.1588.2.1.1.1.24.2.1.1
Description This object identifies the switch port index.
Note: The value of a port index is 1 higher than the port number labeled on the front
panel. For exmaple, port index 1 corresponds to port number 0.
swTrunkGroupNumber
OID 1.3.6.1.4.1.1588.2.1.1.1.24.2.1.2
Description This object is a logical entity, which specifies the Group
Number to which the port belongs. If this value is Zero, it means
the port is not trunked.
swTrunkMaster
OID 1.3.6.1.4.1.1588.2.1.1.1.24.2.1.3
Description Port number that is the trunk master of the group. The trunk
master implicitly defines the group. All ports with the same
master are considered to be part of the same group.
swPortTrunked
OID 1.3.6.1.4.1.1588.2.1.1.1.24.2.1.4
Description The current state of trunking for a member port. Possible values
are:
Disabled (0)
Enabled (1)
swTrunkGrpTable
OID 1.3.6.1.4.1.1588.2.1.1.1.24.3
Description Table to display trunking performance information for the
switch.
swTrunkGrpEntry
OID 1.3.6.1.4.1.1588.2.1.1.1.24.3.1
Description Entry for the trunking group table.
Index swTrunkGrpNumber
swTrunkGrpNumber
OID 1.3.6.1.4.1.1588.2.1.1.1.24.3.1.1
Description This object is a logical entity which specifies the Group Number
to which the port belongs.
swTrunkGrpMaster
OID 1.3.6.1.4.1.1588.2.1.1.1.24.3.1.2
Description This object gives the master port id for the TrunkGroup.
swTrunkGrpTx
OID 1.3.6.1.4.1.1588.2.1.1.1.24.3.1.3
Description Gives the aggregate value of the transmitted words from this
TrunkGroup.
swTrunkGrpRx
OID 1.3.6.1.4.1.1588.2.1.1.1.24.3.1.4
Description Gives the aggregate value of the received words by this
TrunkGroup.
Overview
The HA-MIB provides information about the High Availability features of Fabric
OS v4.x. This MIB is supported only in Fabric OS v4.1 and is not supported in
Fabric OS v3.x or Fabric OS v2.6.1.
The HA-MIB has a dependency on the SW MIB. A management application must
load the SW MIB before it can load the HA-MIB.
The descriptions of each of the MIB variables in this chapter come directly from
the HA-MIB itself.
The object types in HA-MIB are organized into the following groupings:
■ The High Availability Group
■ The HA MIB Traps
Figure 22 and Figure 23 depict the organization and structure of the HA-MIB file
system.
- iso (1)
- org (3)
- dod (6)
- internet (1)
- private (4)
- enterprises (1)
- bsci (1588)
- commDev (2)
- fibreChannel (1)
- haMIB (2)
- highAvailability (1)
- haMIBTraps (2)
- haMIB (1.3.6.1.4.1.1588.2.1.2)
- highAvailability (1)
- haStatus (1)
- fruTable (5)
- fRUEntry (1)
- fruClass (1)
- fruStatus (2)
- fruObjectNum (3)
- fruHistoryTable (6)
- fruHistoryEntry (1)
- fruHistoryIndex (1)
- fruHistoryClass (2)
- fruHistoryObjectNum (3)
- fruHistoryEvent (4)
- fruHistoryTime (5)
- fruHistoryBrocadePartNum (6)
- fruHistoryBrocadeSerialNum (7)
- cpTable (7)
- cpEntry (1)
- cpStatus (1)
- cpIpAddress (2)
- cpIpMask (3)
- cpIpGateway (4)
- cpLastEvent (5)
- haMIBTraps (2)
- haMIBTrapPrefix (0)
- fruStatusChanged (1)
- cpStatusChanged (2)
- fruHistoryTrap (3)
Table 10 lists the objects or definitions that are imported into the HA-MIB and the
modules from which they are imported.
Table 10: Objects Imported into the HA-MIB
Object Imported from this Module
MODULE-IDENTITY SNMPv2-SMI
OBJECT-TYPE
NOTIFICATION-TYPE
TimeTicks
Integer32
IpAddress
mib-2
fibrechannel SW-MIB
OID 1.3.6.1.4.1.1588.2.1.2.1.1
Description Indicates whether the system is redundant. Possible values
are:
redundant (0)
nonredundant (1)
FRU Table
fruTable
OID 1.3.6.1.4.1.1588.2.1.2.1.5
Description This table inventories the field replaceable unit (FRU) slots
available. This table contains an entry for each entry in the
entPhysicalTable that has entPhysicalClass set to “Container
(5)” and has a child entry having entPhysicalIsFRU set to
“true (1).”
fRUEntry
OID 1.3.6.1.4.1.1588.2.1.2.1.5.1
Description An entry for FRU slot in the fruTable
Index entPhysicalIndex
fruClass
OID 1.3.6.1.4.1.1588.2.1.2.1.5.1.1
Description The type of the FRU object that this slot can hold. Possible
values are:
other (1)
unknown (2)
chassis (3)
cp (4)
other-CP (5)
switchblade (6)
wwn (7)
powerSupply (8)
fan (9)
fruStatus
OID 1.3.6.1.4.1.1588.2.1.2.1.5.1.2
Description The current status of the FRU object in the slot. Possible
values are:
other (1)
unknown (2)
on (3)
off (4)
faulty (5)
fruObjectNum
OID 1.3.6.1.4.1.1588.2.1.2.1.5.1.3
Description The slot number of the blade, and the unit number for
everything else.
OID 1.3.6.1.4.1.1588.2.1.2.1.6
Description This table gives the contents of the entire history log of the
FRU events.
fruHistoryEntry
OID 1.3.6.1.4.1.1588.2.1.2.1.6.1
Description An entry in this table represents a particular FRU event.
Index fruHistoryIndex
fruHistoryIndex
OID 1.3.6.1.4.1.1588.2.1.2.1.6.1.1
Description Index of the FRU event in the history table.
fruHistoryClass
OID 1.3.6.1.4.1.1588.2.1.2.1.6.1.2
Description The type of the FRU object related to the event. Possible
values are:
other (1)
unknown (2),
chassis (3),
cp (4),
other-CP (5),
switchblade (6),
wwn (7),
powerSupply (8),
fan (9)
fruHistoryObjectNum
OID 1.3.6.1.4.1.1588.2.1.2.1.6.1.3
Description The slot number of the blade, and the unit number for
everything else.
fruHistoryEvent
OID 1.3.6.1.4.1.1588.2.1.2.1.6.1.4
Description The type of the FRU event. Possible values are:
added (1)
removed (2)
invalid (3)
fruHistoryTime
OID 1.3.6.1.4.1.1588.2.1.2.1.6.1.5
Description The time at which this event happened.
fruHistoryBrocadePartNum
OID 1.3.6.1.4.1.1588.2.1.2.1.6.1.6
Description The HP part number of the FRU object.
fruHistoryBrocadeSerialNum
OID 1.3.6.1.4.1.1588.2.1.2.1.6.1.7
Description The HP serial number of the FRU object.
OID 1.3.6.1.4.1.1588.2.1.2.1.7
Description This table lists all the Control Processors (CPs) in the system.
cpEntry
OID 1.3.6.1.4.1.1588.2.1.2.1.7.1
Description An entry represents a single CP in the system.
Index entPhysicalIndex
cpStatus
OID 1.3.6.1.4.1.1588.2.1.2.1.7.1.1
Description The current status of the CP. Possible values are:
other (1)
unknown (2)
active (3)
standby (4)
failed (5)
cpIpAddress
OID 1.3.6.1.4.1.1588.2.1.2.1.7.1.2
Description The IP Address of the Ethernet interface of this CP.
cpIpMask
OID 1.3.6.1.4.1.1588.2.1.2.1.7.1.3
Description The IP Mask of the Ethernet interface of this CP.
cpIpGateway
OID 1.3.6.1.4.1.1588.2.1.2.1.7.1.4
Description The IP Address of the IP Gateway for this CP.
cpLastEvent
OID 1.3.6.1.4.1.1588.2.1.2.1.7.1.5
Description The last event related to this CP. Possible values are:
haSync (1)
haOutSync (2)
cpFaulty (3)
cpHealthy (4)
configChange (5)
failOverStart (6)
failOverDone (7)
firmwareCommit (8)
firmwareUpgrade (9)
other (10)
unknown (11)
haMIBTraps
This section lists the HA-MIB traps.
fruStatusChanged
OID 1.3.6.1.4.1.1588.2.1.2.2.0.1
Objects entPhysicalName
fruStatus
Status Current
Description This trap is sent when the status of any FRU object changes.
cpStatusChanged
OID 1.3.6.1.4.1.1588.2.1.2.2.0.2
Objects cpStatus
cpLastEvent
swID
swSsn
Status Current
Description This trap is sent when status of any CP object changes.
fruHistoryTrap
OID 1.3.6.1.4.1.1588.2.1.2.2.0.3
Objects fruHistoryClass
fruHistoryObjectNum
fruHistoryEvent
fruHistoryTime
fruHistoryBrocadePartNum
fruHistoryBrocadeSerialNum
Status Current
Description This trap is sent when a FRU is added or removed.
Overview
The descriptions of each of the MIB variables in this chapter come directly from
the FCMGMT-MIB itself. The notes that follow the descriptions typically pertain
to HP-specific information and are provided by HP.
The object types in FCMGMT-MIB are organized into the following groupings:
■ Connectivity
■ Trap Registration
■ Revision Number
■ Statistic Set
■ Service Set
- iso (1)
- org (3)
- dod (6)
- internet (1)
- experimental (3)
- fcmgmt (94)
- connSet (1)
- uNumber (1)
- systemURL (2)
- connUnitTable (6)
- connUnitRevsTable (7)
- connUnitSensorTable (8)
- connUnitPortTable (10)
- connUnitEventTable (11)
- connUnitLinkTable (12)
- trapReg (2)
- trapMaxClients (1)
- trapClientCount (2)
- trapRegTable (3)
- revisionNumber (3)
- statSet (4)
- connUnitPortStatTable (5)
- connUnitServiceSet (5)
- connUnitServiceScalars (1)
- connUnitSnsMaxEntry (1)
- connUnitServiceTables (2)
- connUnitSnsTable (1)
trapReg (1.3.6.1.3.94.2)
- trapRegTable (3)
- trapRegEntry (1)
- trapRegIpAddress (1)
- trapRegPort (2)
- trapRegFilter (3)
- trapRegRowState (4)
- connUnitServiceTables (1.3.6.1.3.94.5.2)
- connUnitSnsTable (1)
- connUnitSnsEntry (1)
- connUnitSnsId (1)
- connUnitSnsPortIndex (2)
- connUnitSnsPortIdentifier (3)
- connUnitSnsPortName (4)
- connUnitSnsNodeName (5)
- connUnitSnsClassOfSvc (6)
- connUnitSnsNodeIPAddress (7)
- connUnitSnsProcAssoc (8)
- connUnitSnsFC4Type (9)
- connUnitSnsPortType (10)
- connUnitSnsPortIPAddress (11)
- connUnitSnsFabricPortName (12)
- connUnitSnsHardAddress (13)
- connUnitSnsSymbolicPortName (14)
- connUnitSnsSymbolicNodeName (15)
- connUnitPortStatTable (1.3.6.1.3.94.4.5)
- connUnitPortStatEntry (1)
- connUnitPortStatUnitId (1)
- connUnitPortStatIndex (2)
- connUnitPortStatCountError (3)
- connUnitPortStatCountTxObjects (4)
- connUnitPortStatCountRxObjects (5)
- connUnitPortStatCountTxElements (6)
- connUnitPortStatCountRxElements (7)
- connUnitPortStatCountBBCreditZero (8)
- connUnitPortStatCountInputBuffersFull (9)
- connUnitPortStatCountFBSYFrames (10)
- connUnitPortStatCountPBSYFrames (11)
- connUnitPortStatCountFRJTFrames (12)
- connUnitPortStatCountPRJTFrames (13)
- connUnitPortStatCountClass1RxFrames (14)
- connUnitPortStatCountClass1TxFrames (15)
- connUnitPortStatCountClass1FBSYFrames (16)
- connUnitPortStatCountClass1PBSYFrames (17)
- connUnitPortStatCountClass1FRJTFrames (18)
- connUnitPortStatCountClass1PRJTFrames (19)
- connUnitPortStatCountClass2RxFrames (20)
- connUnitPortStatCountClass2TxFrames (21)
- connUnitPortStatCountClass2FBSYFrames (22)
- connUnitPortStatCountClass2PBSYFrames (23)
- connUnitPortStatCountClass2FRJTFrames (24)
- connUnitPortStatCountClass2PRJTFrames (25)
- connUnitPortStatCountClass3RxFrames (26)
- connUnitPortStatCountClass3TxFrames (27)
- connUnitPortStatCountClass3Discards (28)
- connUnitPortStatCountRxMulticastObjects (29)
- connUnitPortStatCountTxMulticastObjects (30)
- connUnitPortStatCountRxBroadcastObjects (31)
- connUnitPortStatCountTxBroadcastObjects (32)
- connUnitPortStatCountRxLinkResets (33)
- connUnitPortStatCountTxLinkResets (34)
- connUnitPortStatCountNumberLinkResets (35)
- connUnitPortStatCountRxOfflineSequences (36)
- connUnitPortStatCountTxOfflineSequences (37)
- connUnitPortStatCountNumberOfflineSequences (38)
- connUnitPortStatCountLinkFailures (39)
- connUnitPortStatCountInvalidCRC (40)
- connUnitPortStatCountInvalidTxWords (41)
- connUnitPortStatCountPrimitiveSequenceProtocolErrors (42)
- connUnitPortStatCountLossofSignal (43)
- connUnitPortStatCountLossofSynchronization (44)
- connUnitPortStatCountInvalidOrderedSets (45)
- connUnitPortStatCountFramesTooLong (46)
- connUnitPortStatCountFramesTruncated (47)
- connUnitPortStatCountAddressErrors (48)
- connUnitPortStatCountDelimiterErrors (49)
- connUnitPortStatCountEncodingDisparityErrors (50)
Connectivity Group
Implementation of the Connectivity group is mandatory for all systems.
uNumber
OID 1.3.6.1.3.94.1.1
Description The number of connectivity units present on this system
(represented by this agent). May be a count of the boards in a
chassis or the number of full boxes in a rack.
systemURL
OID 1.3.6.1.3.94.1.2
Description The top-level URL of the system. If it does not exist, the value
is an empty string. The URL format is
implementation-dependant and can have keywords embedded
that are preceded by a percent sign (for example,%USER).
The following are the defined keywords that are recognized
and replaced with data during a launch:
USER: Replace with username.
PASSWORD: Replace with password.
GLOBALID: Replace with globalid.
SERIALNO: Replace with serial number.
OID 1.3.6.1.3.94.1.6
Description A list of units under a single SNMP agent. The number of
entries is given by the value of uNumber. The value is 1 for
stand-alone system.
connUnitEntry
OID 1.3.6.1.3.94.1.6.1
Description A connectivity unit entry containing objects for a particular
unit.
Index connUnitId
connUnitId
OID 1.3.6.1.3.94.1.6.1.1
Description The unique identification for this connectivity unit among
those within this proxy domain. The value must be unique
within the proxy domain because it is the index variable for
connUnitTable. The value assigned to a given connectivity
unit should be persistent across agent and unit resets. It should
be the same as connUnitGlobalId, if connUnitGlobalId is
known and stable.
Note: HP’s implementation maps the switch WWN to the top 8 octets of this variable
and sets the remaining lower 8 octets to 0.
To specify a particular instance of any columnar variable in the connUnitEntry (such as
connUnitType), specify the instance identifier as a 16-octet value.
Example:
connUnitType.10.0.0.60.69.4.11.19.0.0.0.0.0.0.0.0
where the object instance identifier consists of 16 octets, each representing the byte
value from high byte order to low byte order of this 128-bit integer.
connUnitGlobalId
OID 1.3.6.1.3.94.1.6.1.2
Description An optional global-scope identifier for this connectivity unit.
It must be a WWN for this connectivity unit or 16 octets of
value zero.
The following characteristics are required:
■ WWN formats requiring fewer than 16 octets must be
extended to 16 octets with trailing zero octets.
■ If a WWN is used for connUnitId, the same WWN must
be used for connUnitGlobalId.
When a non-zero value is provided, the following
characteristics are strongly recommended:
■ It should be persistent across agent and unit resets.
■ It should be globally unique.
■ It should be one of these FC-PH/PH3 formats:
— IEEE (NAA=1)
— IEEE Extended (NAA=2)
— IEEE Registered (NAA=5)
— IEEE Registered extended (NAA=6)
Use of the IEEE formats allows any IEEE-registered vendor
to assure global uniqueness independently. The following are
some references on IEEE WWN formats:
http://standards.ieee.org/regauth/oui/tutorials/fibreformat.html
http://standards.ieee.org/regauth/oui/tutorials/fibrecomp_id.html
If one or more WWNs are associated with the connUnit via
other management methods, one of them should be used for
connUnitGlobalId.
If a WWN is not assigned specifically to the connUnit, there
is some merit, though not a requirement, to using a WWN
assigned to (one of) its permanently attached FC/LAN
interfaces. This cannot risk uniqueness, though.
Note: HP’s implementation maps the switch WWN to the top 8 octets of this variable
and sets the remaining lower 8 octets to 0.
Example:
If the HP switch WWN is 10:0:0:60:69:10:02:18, then SNMP GET on
connUnitGlobalId.10.0.0.60.69.10.02.18.0.0.0.0.0.0.0.0
returns:
10 00 00 60 69 10 02 18 00 00 00 00 00 00 00 00
connUnitType
OID 1.3.6.1.3.94.1.6.1.3
Description The type of this connectivity unit.
connUnitNumports
OID 1.3.6.1.3.94.1.6.1.4
Description Number of physical ports (between 0 and the maximum
number of system supported ports) in the connectivity unit
(internal/embedded, external).
connUnitState
OID 1.3.6.1.3.94.1.6.1.5
Description Overall state of the connectivity unit. Possible values are:
unknown (1):
online (2): Set the state to online.
offline (3): Set the state to offline.
connUnitStatus
OID 1.3.6.1.3.94.1.6.1.6
Description Overall status of the connectivity unit. Possible values are:
unknown (1)
unused (2)
ok (3)
warning (4): Needs attention.
failed (5)
connUnitProduct
OID 1.3.6.1.3.94.1.6.1.7
Description The connectivity unit vendor's product model name.
Note: This is the same as for sysDescr (set for as many as 79 bytes).
connUnitSn
OID 1.3.6.1.3.94.1.6.1.8
Description The serial number for this connectivity unit.
Note: Set to the SSN (which by default is the WWN), but is changeable through telnet.
connUnitUpTime
OID 1.3.6.1.3.94.1.6.1.9
Description The number of centiseconds since the last unit initialization.
connUnitUrl
OID 1.3.6.1.3.94.1.6.1.10
Description URL to launch a management application, if applicable.
Otherwise empty string. In a standalone unit, this would be
the same as the top-level URL. This has the same definition as
systemURL for keywords.
connUnitDomainId
OID 1.3.6.1.3.94.1.6.1.11
Description 24-bit Fibre Channel address ID of this connectivity unit,
right justified with leading zeros if required. If this value is
not applicable, return all bits set to one.
connUnitProxyMaster
OID 1.3.6.1.3.94.1.6.1.12
Description A value of “yes” means this is the proxy master unit for a set
of managed units. Possible values are:
unknown (1)
no (2)
yes (3)
Example:
This could be the only unit with a management card in it for a
set of units. A standalone unit should return “yes” for this
object.
connUnitPrincipal
OID 1.3.6.1.3.94.1.6.1.13
Note: If the switch is principal, this is set to 3 (yes), otherwise, it is set to 2 (no).
connUnitNumSensors
OID 1.3.6.1.3.94.1.6.1.14
Description Number of sensors (between 0 and maximum number of
sensors) in the connUnitSensorTable.
Note: Core Switch 2/64: This value is between 0 and 62. (The configurations for this
switch vary too greatly to list them for each specific type of sensor.)
SAN Switch 2/16: This value is between 0 and 13 (temperature = 6, fan = 3, power
supply = 4).
connUnitStatusChangeTime
OID 1.3.6.1.3.94.1.6.1.15
Description The sysuptime timestamp (in centiseconds) at which the last
status change occurred for any members of the set. In other
words, this is the latest timestamp that connUnitStatus or
connUnitPortStatus changed.
connUnitConfigurationChangeTime
OID 1.3.6.1.3.94.1.6.1.16
Description The sysuptime timestamp (in centiseconds) at which the last
configuration change occurred for any members of the set. In
other words, this is the latest timestamp of flash memory
update.This represents a union of change information for
connUnitConfigurationChangeTime
connUnitNumRevs
OID 1.3.6.1.3.94.1.6.1.17
Description The number of revisions in the connUnitRevsTable.
Note: Set to 2.
connUnitNumZones
OID 1.3.6.1.3.94.1.6.1.18
Description Number of zones defined in connUnitZoneTable.
connUnitModuleId
OID 1.3.6.1.3.94.1.6.1.19
Description This is a unique ID, persistent between boots, that can be used
to group a set of connUnits together into a module. The
intended use would be to create a connUnit with a
connUnitType of module to represent a physical or logical
group of connectivity units. Then the value of the group
would be set to the value of connUnitId for this container
connUnit.
connUnitModuleId should be zeros if this connUnit is not part
of a module.
connUnitName
OID 1.3.6.1.3.94.1.6.1.20
Description A display string containing a name for this connectivity unit.
This object value should be persistent between boots.
connUnitInfo
OID 1.3.6.1.3.94.1.6.1.21
Description A display string containing information about this
connectivity unit. This object value should be persistent
between boots.
connUnitControl
OID 1.3.6.1.3.94.1.6.1.22
Note: Declarations 3 and 4 perform the same operation—a warm boot of the switch.
connUnitContact
OID 1.3.6.1.3.94.1.6.1.23
Description Contact information for this connectivity unit.
Note: Displays the same value as in sysContact. Changing the value in this variable
causes the value in sysContact to also be changed.
connUnitLocation
OID 1.3.6.1.3.94.1.6.1.24
Description Location information for this connectivity unit.
connUnitEventFilter
OID 1.3.6.1.3.94.1.6.1.25
Description This value defines the event severity that is logged by this
connectivity unit. All events of severity less than or equal to
connUnitEventFilter are logged in connUnitEventTable.
connUnitNumEvents
OID 1.3.6.1.3.94.1.6.1.26
Description Number of events currently in the connUnitEventTable.
Note: Returns the number of events that are currently in buffer (between 0 and 256).
connUnitMaxEvents
OID 1.3.6.1.3.94.1.6.1.27
Description Maximum number of events (256) that can be defined in
connUnitEventTable.
connUnitEventCurrID
OID 1.3.6.1.3.94.1.6.1.28
Description The last used event ID (connUnitEventId).
OID 1.3.6.1.3.94.1.7
Description Table of the revisions supported by connectivity units
managed by this agent.
Note: This table lists the versions of hardware and software elements in the switch.
connUnitRevsEntry
OID 1.3.6.1.3.94.1.7.1
Description Table of the revisions supported by connectivity units
managed by this agent.
Index connUnitRevsUnitId
connUnitRevsIndex
connUnitRevsUnitId
OID 1.3.6.1.3.94.1.7.1.1
Description The connUnitId of the connectivity unit that contains this
revision table.
connUnitRevsIndex
OID 1.3.6.1.3.94.1.7.1.2
Description A unique value among all connUnitRevsEntrys with the same
value of connUnitRevsUnitId, in the range between 1 and
connUnitNumRevs.
Note: Index 1 returns the hardware version. Index 2 returns the software version.
connUnitRevsRevId
OID 1.3.6.1.3.94.1.7.1.3
Description A vendor-specific string identifying a revision of a component
of the connUnit indexed by connUnitRevsUnitId.
Note: Index 1 returns the switchType from telnet command switchShow. Index 2
returns the Fabric OS version from telnet command version, for example, v2.6.
connUnitRevsDescription
OID 1.3.6.1.3.94.1.7.1.4
Description Description of a component to which the revision
corresponds.
Note: Index 1 returns the hardware version. Index 2 returns the software version.
OID 1.3.6.1.3.94.1.8
Description Table of the sensors supported by each connectivity unit
managed by this agent.
connUnitSensorEntry
OID 1.3.6.1.3.94.1.8.1
Description Each entry contains the information for a specific sensor.
Index connUnitSensorUnitId
connUnitSensorIndex
connUnitSensorUnitId
OID 1.3.6.1.3.94.1.8.1.1
Description The connUnitId of the connectivity unit that contains this
sensor table.
connUnitSensorIndex
OID 1.3.6.1.3.94.1.8.1.2
Description A unique value among all connUnitSensorEntrys with the
same value of connUnitSensorUnitId, in the range between 1
and the return value from connUnitNumSensor.
connUnitSensorName
OID 1.3.6.1.3.94.1.8.1.3
Description A textual identification of the sensor intended primarily for
operator use.
Note: Each contains the name of sensor in textual format. (For example, Temp #1, Fan
#2, and so on.)
connUnitSensorStatus
OID 1.3.6.1.3.94.1.8.1.4
Description The status indicated by the sensor. Possible values are:
unknown (1)
other (2)
ok (3): The sensor indicates okay.
warning (4): The sensor indicates a warning.
failed (5): The sensor indicates failure.
connUnitSensorInfo
OID 1.3.6.1.3.94.1.8.1.5
Description Miscellaneous static information about the sensor such as its
serial number.
connUnitSensorMessage
OID 1.3.6.1.3.94.1.8.1.6
Description This describes the status of the sensor as a message. It may
also provide more resolution on the sensor indication, for
example, Cover temperature 1503K, above nominal operating
range.
Note: Each contains the sensor status (and reading if applicable) in textual format.
connUnitSensorType
OID 1.3.6.1.3.94.1.8.1.7
Description The type of component being monitored by this sensor.
Possible values are:
unknown (1)
other (2)
battery (3)
fan (4)
power-supply (5)
transmitter (6)
enclosure (7)
board (8)
receiver (9)
Note: The following mapping is for each individual sensor, where applicable:
swSensorType connUnitSensorType
1 (temperature) 8 (board)
2 (fan) 4 (fan)
3 (power-supply) 5 (power supply)
connUnitSensorCharacteristic
OID 1.3.6.1.3.94.1.8.1.8
Note: The following mapping is for each individual sensor, where applicable:
swSensorType connUnitSensorCharacteristic
1 (temperature) 3 (temperature)
2 (fan) 7 (airflow)
3 (power-supply) 9 (power)
OID 1.3.6.1.3.94.1.10
Description Generic information on ports for a specific connUnit.
connUnitPortEntry
OID 1.3.6.1.3.94.1.10.1
Description Each entry contains the information for a specific port.
Index connUnitPortUnitId
connUnitPortIndex
connUnitPortUnitId
OID 1.3.6.1.3.94.1.10.1.1
Description The connUnitId of the connectivity unit that contains this
port.
connUnitPortIndex
OID 1.3.6.1.3.94.1.10.1.2
Description Number of physical ports between (0 and maximum number
of system supported ports) in the connectivity unit
(internal/embedded, external).
connUnitPortType
OID 1.3.6.1.3.94.1.10.1.3
Description The port type. Possible values are:
unknown (1)
other (2)
not-present (3)
hub-port (4)
n-port (5): End port for fabric.
l-port (6): End port for loop.
fl-port (7): Public loop.
f-port (8): Fabric port.
e-port (9): Fabric expansion port.
g-port (10): Generic fabric port.
domain-ctl (11): Domain controller.
hub-controller (12)
scsi (13): Parallel SCSI port.
escon (14)
lan (15)
wan (16)
ac (17): AC power line. (Not supported in
Fabric OS v2.6.1.)
dc (18): DC power line. (Not supported in
Fabric OS v2.6.1)
ssa (19): Serial storage architecture. (Not
supported in Fabric OS v2.6.1.)
connUnitPortFCClassCap
OID 1.3.6.1.3.94.1.10.1.4
Description Bit mask that specifies the classes of service capability of this
port. If this is not applicable, return all bits set to zero.
The bits have the following definition:
unknown - 0
class-f - 1
class-one - 2
class-two - 4
class-three - 8
class-four - 16
class-five - 32
class-six - 64
Note: For an F or FL_port, this value is 0x000C. For a G or E_port, this value is
0x000D.
connUnitPortFCClassOp
OID 1.3.6.1.3.94.1.10.1.5
Description Bit mask that specifies the classes of service that are currently
operational. If this is not applicable, return all bits set to zero.
This object has the same definition as
connUnitPortFCClassCap.
Note: For an F or FL_port, this value is 0x000C. For a G or E_port, this value is
0x000D.
connUnitPortState
OID 1.3.6.1.3.94.1.10.1.6
Description The state of the port hardware. Possible values are:
unavailable (1): Do not use.
online (2): Available for meaningful work.
offline (3): Not available for meaningful work.
bypassed (4): No longer used.
diagnostics (5): Map to your testing. (Not supported in
Fabric OS v2.6.1.)
Note: For an E, F, or FL_port, the value is online. For a U_port, the value is offline
(disabled, testing, faulted).
connUnitPortStatus
OID 1.3.6.1.3.94.1.10.1.7
Description An overall protocol status for the port. Possible values are:
unknown (1)
unused (2): Device cannot report this status.
ready (3): FCAL Loop or FCPH Link reset
protocol initialization has completed.
warning (4): Do not use.
failure (5): Do not use.
notparticipating (6):Loop not participating and does not
have a loop address.
initializing (7): Protocol is proceeding.
bypass (8): Do not use.
ols (9): FCP offline status. (Not supported in
Fabric OS v2.6.1).
Note: For an E, F, or FL_port, the value is 3 (ok). For a U_port, the value is 2 (unused)
if not faulty with GBIC, 3 (warning) if not faulty but no GBIC, or 5 (failure) if faulty.
connUnitPortTransmitterType
OID 1.3.6.1.3.94.1.10.1.8
Description The technology of the port transceiver. Possible values are:
unknown (1)
other (2)
unused (3)
shortwave (4)
longwave (5)
copper (6)
scsi (7)
longwaveNoOFC (8)
shortwaveNoOFC (9)
longwaveLED (10)
ssa (11) (Not supported in Fabric OS v2.6.1.)
connUnitPortModuleType
OID 1.3.6.1.3.94.1.10.1.9
Description The module type of the port connector. Possible values are:
unknown (1)
other (2)
gbic (3)
embedded (4): Fixed. (oneXnine)
glm (5)
gbicSerialId (6)
gbicNoSerialId (7)
gbicNotInstalled (8)
smallFormFactor (9)
Note: For an external FC_port with GBIC, this value should be 6 (gbicSerialId) or 7
(gbicNoSerialId). For an external FC_port without GBIC, this value is set to 8
(gbicNotInstalled).
connUnitPortWwn
OID 1.3.6.1.3.94.1.10.1.10
Description The World Wide Name (WWN) of the port, if applicable,
otherwise empty string.
This is in IEEE Extended format, and the extension contains
the internal port number of each port.
Note: The internal port number is 1 less than the port index.
Example:
If the switch has WWN 10:00:00:60:69:10:02:18, then port numbers 0 and 6 have
WWN 20:00:00:60:69:10:02:18 and 20:06:00:60:69:10:02:18
respectively. However, the embedded port has WWN
10:00:00:60:69:10:02:18, the same as the switch.
connUnitPortFCId
OID 1.3.6.1.3.94.1.10.1.11
Description This is the assigned Fibre Channel ID of this port. This value
is expected to be a Big Endian value of 24 bits. If this is a
loop, then it is the ALPA that is connected. If this is an
E_port, then it contains only the domain ID left justified, zero
filled. If this port does not have a Fibre Channel address,
return all bits set to 1.
Note: For an F_port, this is the Fibre Channel ID to which the connected N_port is
assigned. For an FL_port, this is the Fibre Channel ID of the FL_port (alpa = 0). For a U
or E_port, this is similar to F_port.
connUnitPortSn
OID 1.3.6.1.3.94.1.10.1.12
Description The serial number of the unit (for example, for a GBIC). If
this is not applicable, return empty string.
Note: If the GBIC has a serial ID, the return value is the GBIC part number. Otherwise
the return value is Null.
connUnitPortRevision
OID 1.3.6.1.3.94.1.10.1.13
Description The port revision (for example, GBIC).
Note: If the GBIC has a serial ID, this returns the GBIC revision number. Otherwise it
returns a Null value.
connUnitPortVendor
OID 1.3.6.1.3.94.1.10.1.14
Description The port vendor (for example, for a GBIC).
Note: If the GBIC has a serial ID, this returns the GBIC vendor name. Otherwise it
returns a Null value.
connUnitPortSpeed
OID 1.3.6.1.3.94.1.10.1.15
Description The speed of the port in kilobytes per second.
Note: The valid values for the Core Switch 2/64: 125,000 or 250,000
connUnitPortControl
OID 1.3.6.1.3.94.1.10.1.16
■ offlineConnUnitPort:
If the addressed connUnit allows this operation to be
performed to this port, the addressed port performs a
vendor-specific offline operation. Examples of these
operations are:
— Disabling a port's transceiver
— The Link Failure protocol
— Request (NON-PARTICIPATING) command to the
Loop port state machine removal of the port from an
arbitrated loop by a hub
■ onlineConnUnitPort:
If the addressed connUnit allows this operation to be
performed to this port, the addressed port performs a
vendor-specific online operation. Examples of these
operations are:
— Enabling a port's transceiver.
— The Link Failure protocol, request
(PARTICIPATING) command to the Loop port state
machine.
— Addition of the port from an arbitrated loop by a hub.
Each implementation may choose not to allow any or all of
these values on a SET.
If the Management Station uses in-band communication
(FC-IP) with the switch, either of the two following actions
may result in a loss of in-band communication with the
switch:
■ Disabling the FC port that is connected to the
Management Station.
■ Disabling the embedded port.
connUnitPortName
OID 1.3.6.1.3.94.1.10.1.17
Description A string describing the addressed port.
connUnitPortPhysicalNumber
OID 1.3.6.1.3.94.1.10.1.18
Description This is the internal port number by which this port is known.
In many implementations, this should be the same as
connUnitPortIndex. Some implementations may have an
internal port representation not compatible with the rules for
table indices. In that case, provide the internal representation
of this port in this object. This value may also be used in the
connUnitLinkPortNumberX or connUnitLinkPortNumberY
objects of the connUnitLinkTable.
connUnitPortStatObject
OID 1.3.6.1.3.94.1.10.1.19
Description This contains the OID of the first object of the table that
contains the statistics for this particular port. If this has a
value of zero, then there are no statistics available for this
port. The port type information helps identify the statistics
objects that are found in the table. From this point, one would
do a getnext to get the next statistics object. When the first
part of the OID changes, the end of table is reached.
connUnitPortProtocolCap
OID 1.3.6.1.3.94.1.10.1.20
Description This is the bit mask that specifies the driver level protocol
capability of this port.
If this is not applicable, return all bits set to zero.
Return value = 07F
connUnitPortProtocolOp
OID 1.3.6.1.3.94.1.10.1.21
Description This is the bit mask that specifies the driver level protocol(s)
that are currently operational.
Return value = 07F
Note: If this is not applicable, return all bits set to zero. The bits have the following
definition:
0 = unknown
1 = Loop
2 = Fabric
4 = SCSI
8 = TCP/IP
16 = VI
32 = FICON
connUnitPortNodeWwn
OID 1.3.6.1.3.94.1.10.1.22
Description The node World Wide Name (WWN) of the port if applicable,
otherwise empty string.
All related ports within a group should have the same node
WWN value. The container is defined as the largest physical
entity.
Example:
All HBA ports on a host will have the same Node WWN. All
ports on the same storage subsystem will have the same Node
WWN.
This is in IEEE Extended format, and the extension contains
the internal port number of each port.
Note: The internal port number is 1 less than the port index.
Example:
If the switch has WWN 10:00:00:60:69:10:02:18, then port number 0 and 6
have WWN 20:00:00:60:69:10:02:18 and 20:06:00:60:69:10:02:18
respectively. However, the embedded port has WWN
10:00:00:60:69:10:02:18, the same as the switch.
connUnitPortHWState
OID 1.3.6.1.3.94.1.10.1.23
Description The state of the port as detected by the hardware. Possible
values are:
unknown (1)
failed (2): Port failed diagnostics (port_flt_state).
bypassed (3): FCAL bypass, loop only (not used).
active (4): Connected to a device (light and sync are
present).
loopback (5): Port in ext loopback (loopback state).
txfault (6): Transmitter fault (bad GBIC).
noMedia (7): Media not installed (GBIC removed).
linkDown (8): Waiting for activity—rx sync (light with
no sync).
OID 1.3.6.1.3.94.1.11
Description The table of connectivity unit events. Errors, warnings, and
information should be reported in this table.
Note: (v3.0 only) This table contains the 64 most-recent event log entries.
(v4.0 only) This table contains the 255 most-recent event log entries.
connUnitEventEntry
OID 1.3.6.1.3.94.1.11.1
Description Each entry contains information on a specific event for the
given connectivity unit.
Index connUnitEventUnitId
connUnitEventIndex
connUnitEventUnitId
OID 1.3.6.1.3.94.1.11.1.1
Description The connUnitId of the connectivity unit that contains this
event table.
:connUnitEventIndex
OID 1.3.6.1.3.94.1.11.1.2
Description Each connectivity unit has its own event buffer. As it wraps, it
may write over previous events. This object is an index into
the buffer. It is recommended that this table is read using
getNexts to retrieve the initial table. The management
application should read the event table at periodic intervals
and then determine if any new entries were added by
comparing the last known index value with the current highest
index value. The management application should then update
its copy of the event table. If the read interval is too long, it is
possible that there may be events that may not be contained in
the agent's internal event buffer.
Example:
An agent may read events 50–75.
At the next read interval, connUnitEventCurrID is 189. If
the management application tries to read event index 76,
and the agent's internal buffer is 100 entries maximum,
event index 76 is no longer available.
The index value is an incrementing integer starting from
one (1) every time there is a table reset. On table reset, all
contents are emptied and all indices are set to zero (0).
When an event is added to the table, the event is assigned
the next higher integer value than the last item entered
into the table. If the index value reaches its maximum
value, the next item entered causes the index value to roll
over and start at one (1) again.
connUnitEventId
OID 1.3.6.1.3.94.1.11.1.3
Description The internal event ID. Incriminated for each event, ranging
between 0 and connUnitMaxEvents. Not used as table index
to simplify the agent implementation. When this reaches the
end of the range specified by connUnitMaxEvents, the ID
rolls over to start at zero. This value is set back to zero at
reset. The relationship of this value to the index is that internal
event ID may represent a smaller number than a 32-bit integer
(for example, maximum 100 entries) and would only have a
value range up to connUnitMaxEvents.
connUnitREventTime
OID 1.3.6.1.3.94.1.11.1.4
Description This is the real time when the event occurred. It has the
following format.
DDMMYYYY HHMMSS
where:
DD = day number
MM = month number
YYYY = year
HH = hours
MM = minutes
SS = seconds
If not applicable, return a NULL string.
connUnitSEventTime
OID 1.3.6.1.3.94.1.11.1.5
Description This is the sysuptime timestamp when the event occurred.
connUnitEventSeverity
OID 1.3.6.1.3.94.1.11.1.6
Description The event severity level.
Note: See FcEventSeverity in Table 11 on page 285 for more information about
severity.
connUnitEventType
OID 1.3.6.1.3.94.1.11.1.7
Description The type of this event. Possible values are:
unknown (1)
other (2)
status (3)
configuration (4)
topology (5)
connUnitEventObject
OID 1.3.6.1.3.94.1.11.1.8
Description This is used with the connUnitEventType to identify which
object the event refers to. It can be the OID of a connectivity
unit or of another object, like connUnitPortStatus[...].
connUnitEventDescr
OID 1.3.6.1.3.94.1.11.1.9
Description The description of the event.
OID 1.3.6.1.3.94.1.12
Description A list of links know to this agent from this connectivity unit to
other connectivity units. X = switch data, Y = other end.
Note: The link table is intended to organize and communicate any information the
agent has, that might assist a management application to discover the connectivity units
in the framework and the topology of their interconnect.
That is, the goal is to assist the management application by mapping the elements of
the framework in addition to listing them.
With this goal, the agent should include as much as it possesses about any links from its
own connectivity units to others, including links among its own units.
An agent should include partial information about links if it is not able to fully define
them in accord with the following structure; however, the information must include either
a nonzero connUnitNodeId- or a nonzero connUnitPortWwn - for each end of the link.
If the agent is able to discover links which do not directly attach to members of its
agency and its discovery algorithm gives some assurance the links are recently valid, it
may include these links.
Link information entered by administrative action may be included even if not validated
directly if the link has at least one endpoint in this agency, but should not be included
otherwise.
A connectivity unit should fill the table in as best it can. One of the methods to fill this in
would be to use the RNID ELS command (ANSI document 99-422v0). This command
queries a port for the information needed for the link table.
This table is accessed either directly if the management software has an index value or
by using GetNext. The value of the indexes are not required to be contiguous. Each
entry created in this table is assigned an index. This relationship is kept persistent until
the entry is removed from the table or the system is reset. The total number of entries are
defined by the size of the table
For an entry to be considered to be valid, both the X (local) and the Y (remote) need to
have one valid value.
connUnitLinkEntry
OID 1.3.6.1.3.94.1.12.1
Description An entry describing a particular link to another.
Index connUnitLinkUnitId
connUnitLinkIndex
connUnitLinkUnitId
OID 1.3.6.1.3.94.1.12.1.1
Description The connUnitId of the connectivity unit that contains this link
table.
connUnitLinkIndex
OID 1.3.6.1.3.94.1.12.1.2
Description This value is used to create a unique value for each entry in
the link table with the same connUnitLinkUnitId. The value
can only be reused if it is not currently in use and the value is
the next candidate to be used. This value is allowed to wrap at
the highest value represented by the number of bits. This
value is reset to zero when the system is reset and the first
value to be used is one.
Indexes maximum number of ports + 1 and above are reserved for end devices, and
are calculated based on portID of the end device(s).
connUnitLinkNodeIdX
OID 1.3.6.1.3.94.1.12.1.3
Description The node WWN of the unit at one end of the link. If the node
WWN is unknown and the node is a connUnit in the
responding agent, then the value of this object must be equal
to its connUnitID.
connUnitLinkPortNumberX
OID 1.3.6.1.3.94.1.12.1.4
Description The port number on the unit specified by
connUnitLinkNodeIdX, if known, otherwise -1. If the value is
nonnegative, then it is equal to connUnitPortPhysicalNumber.
connUnitLinkPortWwnX
OID 1.3.6.1.3.94.1.12.1.5
Description The port WWN of the unit specified by
connUnitLinkNodeIdX, if known, otherwise 16 octets of
binary 0.
connUnitLinkNodeIdY
OID 1.3.6.1.3.94.1.12.1.6
Description The node WWN of the unit at the other end of the link. If the
node WWN is unknown and the node is a connUnit in the
responding SNMP agency, then the value of this object must
be equal to its connUnitID.
connUnitLinkPortNumberY
OID 1.3.6.1.3.94.1.12.1.7
Description The port number on the unit specified by
connUnitLinkNodeIdY, if known, otherwise -1. If the value is
nonnegative, then it is equal to connUnitPortPhysicalNumber.
connUnitLinkPortWwnY
OID 1.3.6.1.3.94.1.12.1.8
Description The port WWN on the unit specified by
connUnitLinkNodeIdY, if known, otherwise 16 octets of
binary 0.
connUnitLinkAgentAddressY
OID 1.3.6.1.3.94.1.12.1.9
Description The address of an FCMGMT MIB agent for the node
identified by connUnitLinkNodeIdY, if known, otherwise 16
octets of binary 0.
connUnitLinkAgentAddressTypeY
OID 1.3.6.1.3.94.1.12.1.10
Description If connUnitLinkAgentAddressY is nonzero, it is a protocol
address. ConnUnitLinkAgentAddressTypeY is the address
family number assigned by IANA to identify the address
format (for example, 1 is Ipv4, 2 is Ipv6).
connUnitLinkAgentPortY
OID 1.3.6.1.3.94.1.12.1.11
Description The IP port number for the agent. This is provided in case the
agent is at a nonstandard SNMP port.
connUnitLinkUnitTypeY
OID 1.3.6.1.3.94.1.12.1.12
Description Type of the FC connectivity unit as defined in connUnitType.
ISL: Switch device.
End devices: End device types based on an FCP Inquiry.
connUnitLinkConnIdY
OID 1.3.6.1.3.94.1.12.1.13
Description This is the Fibre Channel ID of this port. If the connectivity
unit is a switch, this is expected to be a Big Endian value of 24
bits. If this is loop, then it is the ALPA that is connected. If
this is an E_port, then it contains only the domain ID. If not
any of those, unknown or cascaded loop, return all bits set
to 1.
connUnitLinkCurrIndex
OID 1.3.6.1.3.94.1.12.1.14
Description The last used link index.
Statistics Group
connUnitPortStatTable
OID 1.3.6.1.3.94.4.5
Description A list of statistics for the fabric port types.
connUnitPortStatEntry
OID 1.3.6.1.3.94.4.5.1
Description An entry describing port statistics.
Index connUnitPortStatUnitId
connUnitPortStatIndex
connUnitPortStatUnitId
OID 1.3.6.1.3.94.4.5.1.1
Description The connUnitId of the connectivity unit that contains this port
stat table.
connUnitPortStatIndex
OID 1.3.6.1.3.94.4.5.1.2
Description A unique value among all entries in this table, between 0 and
connUnitNumPort[connUnitPortUnitId].
connUnitPortStatCountError
OID 1.3.6.1.3.94.4.5.1.3
Description A count of the errors that have occurred on this port.
connUnitPortStatCountTxObjects
OID 1.3.6.1.3.94.4.5.1.4
Description The number of frames/packets/IOs/etc that have been
transmitted by this port.
Note: A Fibre Channel frame starts with SOF and ends with EOF. FC loop devices
should not count passed through frames. This value represents the sum total for all other
Tx objects.
connUnitPortStatCountRxObjects
OID 1.3.6.1.3.94.4.5.1.5
Description The number of frames/packets/IOs/etc that have been received
by this port.
Note: A Fibre Channel frame starts with SOF and ends with EOF. FC loop devices
should not count passed through frames. This value represents the sum total for all other
Rx objects.
connUnitPortStatCountTxElements
OID 1.3.6.1.3.94.4.5.1.6
Description The number of octets or bytes that have been transmitted by
this port. One second periodic polling of the port. This value
is saved and compared with the next polled value to compute
net throughput.
Note: For Fibre Channel, ordered sets are not included in the count.
connUnitPortStatCountRxElements
OID 1.3.6.1.3.94.4.5.1.7
Description The number of octets or bytes that have been received by this
port. One second periodic polling of the port. This value is
saved and compared with the next polled value to compute net
throughput.
Note: For Fibre Channel, ordered sets are not included in the count.
connUnitPortStatCountBBCreditZero
OID 1.3.6.1.3.94.4.5.1.8
Description The number of transitions in/out of BB credit zero state. The
other side is not providing any credit.
connUnitPortStatCountInputBuffersFull
OID 1.3.6.1.3.94.4.5.1.9
Description The number of occurrences when all input buffers of a port
were full and outbound buffer-to-buffer credit transitioned to
zero. There is no credit to provide to other side.
Return Value: 80 0 0 0 0 0 0 0 (Not Supported)
connUnitPortStatCountFBSYFrames
OID 1.3.6.1.3.94.4.5.1.10
Description The number of times that FBSY was returned to this port as a
result of a frame that could not be delivered to the other end of
the link. This occurs if either the Fabric or the destination port
is temporarily busy. Port can only occur on SOFc1 frames (the
frames that establish a connection).
Note: This is a Fibre Channel only stat. This is the sum of all classes. If you cannot keep
the by class counters, then keep the sum counters.
connUnitPortStatCountPBSYFrames
OID 1.3.6.1.3.94.4.5.1.11
Description The number of times that PBSY was returned to this port as a
result of a frame that could not be delivered to the other end of
the link. This occurs if the destination port is temporarily
busy. PBSY can only occur on SOFc1 frames (the frames that
establish a connection).
Return Value: 80 0 0 0 0 0 0 0 (Not Supported)
Note: This is a Fibre Channel only stat.This is the sum of all classes. If you cannot keep
the by class counters, then keep the sum counters.
connUnitPortStatCountFRJTFrames
OID 1.3.6.1.3.94.4.5.1.12
Description The number of times that FRJT was returned to this port as a
result of a Frame that was rejected by the fabric.
Note: This is the total for all classes and is a Fibre Channel only stat.
connUnitPortStatCountPRJTFrames
OID 1.3.6.1.3.94.4.5.1.13
Description The number of times that FRJT was returned to this port as a
result of a Frame that was rejected at the destination N_port.
Return Value: 80 0 0 0 0 0 0 0
Note: This is the total for all classes and is a Fibre Channel only stat.
connUnitPortStatCountClass1RxFrames
OID 1.3.6.1.3.94.4.5.1.14
Description The number of Class 1 Frames received at this port.
connUnitPortStatCountClass1TxFrames
OID 1.3.6.1.3.94.4.5.1.15
Description The number of Class 1 Frames transmitted out this port.
connUnitPortStatCountClass1FBSYFrames
OID 1.3.6.1.3.94.4.5.1.16
Description The number of times that FBSY was returned to this port as a
result of a Class 1 Frame that could not be delivered to the
other end of the link. This occurs if either the Fabric or the
destination port is temporarily busy. FBSY can only occur on
SOFc1 frames (the frames that establish a connection).
connUnitPortStatCountClass1PBSYFrames
OID 1.3.6.1.3.94.4.5.1.17
Description The number of times that PBSY was returned to this port as a
result of a Class 1 Frame that could not be delivered to the
other end of the link. This occurs if the destination N_port is
temporarily busy. PBSY can only occur on SOFc1 frames (the
frames that establish a connection).
connUnitPortStatCountClass1FRJTFrames
OID 1.3.6.1.3.94.4.5.1.18
Description The number of times that FRJT was returned to this port as a
result of a Class 1 Frame that was rejected by the fabric.
connUnitPortStatCountClass1PRJTFrames
OID 1.3.6.1.3.94.4.5.1.19
Description The number of times that FRJT was returned to this port as a
result of a Class 1 Frame that was rejected at the destination
N_port.
connUnitPortStatCountClass2RxFrames
OID 1.3.6.1.3.94.4.5.1.20
Description The number of Class 2 Frames received at this port.
connUnitPortStatCountClass2TxFrames
OID 1.3.6.1.3.94.4.5.1.21
Description The number of Class 2 Frames transmitted out this port.
Return Value: 80 0 0 0 0 0 0 0
connUnitPortStatCountClass2FBSYFrames
OID 1.3.6.1.3.94.4.5.1.22
Description The number of times that FBSY was returned to this port as a
result of a Class 2 Frame that could not be delivered to the
other end of the link. This occurs if either the Fabric or the
destination port is temporarily busy. FBSY can only occur on
SOFc1 frames (the frames that establish a connection).
Return Value: 80 0 0 0 0 0 0 0
connUnitPortStatCountClass2PBSYFrames
OID 1.3.6.1.3.94.4.5.1.23
Description The number of times that PBSY was returned to this port as a
result of a Class 2 Frame that could not be delivered to the
other end of the link. This occurs if the destination N_port is
temporarily busy. PBSY can only occur on SOFc1 frames (the
frames that establish a connection).
Return Value: 80 0 0 0 0 0 0 0
connUnitPortStatCountClass2FRJTFrames
OID 1.3.6.1.3.94.4.5.1.24
Description The number of times that FRJT was returned to this port as a
result of a Class 2 Frame that was rejected by the fabric.
Return Value: 80 0 0 0 0 0 0 0
connUnitPortStatCountClass2PRJTFrames
OID 1.3.6.1.3.94.4.5.1.25
Description The number of times that FRJT was returned to this port as a
result of a Class 2 Frame that was rejected at the destination
N_port.
Return Value: 80 0 0 0 0 0 0 0 (Not Supported)
connUnitPortStatCountClass3RxFrames
OID 1.3.6.1.3.94.4.5.1.26
Description The number of Class 3 Frames received at this port.
connUnitPortStatCountClass3TxFrames
OID 1.3.6.1.3.94.4.5.1.27
Description The number of Class 3 Frames transmitted out this port.
connUnitPortStatCountClass3Discards
OID 1.3.6.1.3.94.4.5.1.28
Description The number of Class 3 Frames that were discarded upon
reception at this port. There is no FBSY or FRJT generated
for Class 3 Frames. They are simply discarded if they cannot
be delivered.
connUnitPortStatCountRxMulticastObjects
OID 1.3.6.1.3.94.4.5.1.29
Description The number of Multicast Frames or Packets received at this
port.
connUnitPortStatCountTxMulticastObjects
OID 1.3.6.1.3.94.4.5.1.30
Description The number of Multicast Frames or Packets transmitted out
this port.
connUnitPortStatCountRxBroadcastObjects
OID 1.3.6.1.3.94.4.5.1.31
Description The number of Broadcast Frames or Packets received at this
port.
Return Value: 80 0 0 0 0 0 0 0 (Not Supported)
connUnitPortStatCountTxBroadcastObjects
OID 1.3.6.1.3.94.4.5.1.32
Description The number of Broadcast frames or packets transmitted out
this port. On a Fibre Channel loop, count only OPNr frames
generated.
Return Value: 80 0 0 0 0 0 0 0 (Not Supported)
connUnitPortStatCountRxLinkResets
OID 1.3.6.1.3.94.4.5.1.33
Description The number of Link resets. This is the number of LRs
received.
connUnitPortStatCountTxLinkResets
OID 1.3.6.1.3.94.4.5.1.34
Description The number of Link resets. This is the number LRs
transmitted.
connUnitPortStatCountNumberLinkResets
OID 1.3.6.1.3.94.4.5.1.35
Description The number of Link resets and LIPs detected at this port. The
number times the reset link protocol is initiated. These are the
count of the logical resets, a count of the number of
primitives.
connUnitPortStatCountRxOfflineSequences
OID 1.3.6.1.3.94.4.5.1.36
Description The number of Offline Primitive OLS received at this port.
connUnitPortStatCountTxOfflineSequences
OID 1.3.6.1.3.94.4.5.1.37
Description The number of Offline Primitive OLS transmitted by this port.
connUnitPortStatCountNumberOfflineSequences
OID 1.3.6.1.3.94.4.5.1.38
Description The number of Offline Primitive sequence received at this
port.
Return Value: 80 0 0 0 0 0 0 0 (Not Supported)
connUnitPortStatCountLinkFailures
OID 1.3.6.1.3.94.4.5.1.39
Description The number of link failures. This count is part of the Link
Error Status Block (LESB). (FC-PH 29.8)
connUnitPortStatCountInvalidCRC
OID 1.3.6.1.3.94.4.5.1.40
Description The number of frames received with invalid CRC. This count
is part of the Link Error Status Block (LESB). (FC-PH 29.8)
Loop ports should not count CRC errors passing through
when monitoring.
connUnitPortStatCountInvalidTxWords
OID 1.3.6.1.3.94.4.5.1.41
Description The number of invalid transmission words received at this
port. This count is part of the Link Error Status Block
(LESB). (FC-PH 29.8)
connUnitPortStatCountPrimitiveSequenceProtocolErrors
OID 1.3.6.1.3.94.4.5.1.42
Description The number of primitive sequence protocol errors detected at
this port. This count is part of the Link Error Status Block
(LESB). (FC-PH 29.8)
connUnitPortStatCountLossofSignal
OID 1.3.6.1.3.94.4.5.1.43
Description The number of instances of signal loss detected at port.
This count is part of the Link Error Status Block (LESB).
(FC-PH 29.8)
connUnitPortStatCountLossofSynchronization
OID 1.3.6.1.3.94.4.5.1.44
Description The number of instances of synchronization loss detected at
port. This count is part of the Link Error Status Block
(LESB). (FC-PH 29.8)
connUnitPortStatCountInvalidOrderedSets
OID 1.3.6.1.3.94.4.5.1.45
Description The number of invalid ordered sets received at port. This
count is part of the Link Error Status Block (LESB). (FC-PH
29.8).
connUnitPortStatCountFramesTooLong
OID 1.3.6.1.3.94.4.5.1.46
Description The number of frames received at this port where the frame
length was greater than what was agreed to in FLOGI/PLOGI.
This could be caused by losing the end of frame delimiter.
connUnitPortStatCountFramesTruncated
OID 1.3.6.1.3.94.4.5.1.47
Description The number of frames received at this port where the frame
length was less than the minimum indicated by the frame
header, normally 24 bytes, but it could be more if the DFCTL
field indicates an optional header should have been present.
connUnitPortStatCountAddressErrors
OID 1.3.6.1.3.94.4.5.1.48
Description The number of frames received with unknown addressing, for
example, unknown SID or DID. The SID or DID is not known
to the routing algorithm.
connUnitPortStatCountDelimiterErrors
OID 1.3.6.1.3.94.4.5.1.49
Description The number of invalid frame delimiters received at this port.
An example is a frame with a class 2 start and a class 3 at the
end.
connUnitPortStatCountEncodingDisparityErrors
OID 1.3.6.1.3.94.4.5.1.50
Service Group
OID 1.3.6.1.3.94.5.1.1
Description The maximum number of entries in the table.
OID 1.3.6.1.3.94.5.2.1
Description This table contains an entry for each object registered with
this port in the switch.
connUnitSnsEntry
OID 1.3.6.1.3.94.5.2.1.1
Description The Simple Name Server table for the port represented by
connUnitSnsPortIndex.
Index connUnitSnsId
connUnitSnsPortIndex
connUnitSnsPortIdentifier
connUnitSnsId
OID 1.3.6.1.3.94.5.2.1.1.1
Description The connUnitId of the connectivity unit that contains this
Name Server table.
connUnitSnsPortIndex
OID 1.3.6.1.3.94.5.2.1.1.2
Description The physical port number of this SNS table entry. Each
physical port has an SNS table with 1-n entries indexed by
connUnitSnsPortIdentifier (port address).
connUnitSnsPortIdentifier
OID 1.3.6.1.3.94.5.2.1.1.3
Description The port identifier for this entry in the SNS table.
connUnitSnsPortName
OID 1.3.6.1.3.94.5.2.1.1.4
Description The port name for this entry in the SNS table.
connUnitSnsNodeName
OID 1.3.6.1.3.94.5.2.1.1.5
Description The Node Name for this entry in the SNS table.
connUnitSnsClassOfSvc
OID 1.3.6.1.3.94.5.2.1.1.6
Description The Classes of Service offered by this entry in the SNS table.
connUnitSnsNodeIPAddress
OID 1.3.6.1.3.94.5.2.1.1.7
Description The IPv6 formatted address of the Node for this entry in the
SNS table.
connUnitSnsProcAssoc
OID 1.3.6.1.3.94.5.2.1.1.8
Description The Process Associator for this entry in the SNS table.
connUnitSnsFC4Type
OID 1.3.6.1.3.94.5.2.1.1.9
Description The FC-4 Types supported by this entry in the SNS table.
connUnitSnsPortType
OID 1.3.6.1.3.94.5.2.1.1.10
Description The port type of this entry in the SNS table.
connUnitSnsPortIPAddress
OID 1.3.6.1.3.94.5.2.1.1.11
Description The IPv6 formatted address of this entry in the SNS table.
connUnitSnsFabricPortName
OID 1.3.6.1.3.94.5.2.1.1.12
Description The fabric port name of this entry in the SNS table.
connUnitSnsHardAddress
OID 1.3.6.1.3.94.5.2.1.1.13
Description The Hard Address of this entry in the SNS table.
connUnitSnsSymbolicPortName
OID 1.3.6.1.3.94.5.2.1.1.14
Description The symbolic port name of this entry in the SNS table.
connUnitSnsSymbolicNodeName
OID 1.3.6.1.3.94.5.2.1.1.15
Description The symbolic node name of this entry in the SNS table.
OID 1.3.6.1.3.94.2.1
Description The maximum number of SNMP trap recipients supported by
the connectivity unit.
Note: Set to 6.
trapClientCount
OID 1.3.6.1.3.94.2.2
Description The current number of rows in the trap table.
trapRegTable
OID 1.3.6.1.3.94.2.3
Description A table containing a row for each IP address/port number to
which traps are sent.
trapRegEntry
OID 1.3.6.1.3.94.2.3.1
Description Ip/Port pair for a specific client.
Index trapRegIpAddress
trapRegPort
trapRegIpAddress
OID 1.3.6.1.3.94.2.3.1.1
Description The IP address of a client registered for traps.
trapRegPort
OID 1.3.6.1.3.94.2.3.1.2
Description The UDP port to send traps to for this host. Normally this
would be the standard trap port (162). This object is an index
and must be specified to create a row in this table.
trapRegFilter
OID 1.3.6.1.3.94.2.3.1.3
Description This value defines the trap severity filter for this trap host. The
connUnit sends traps to this host that have a severity level less
than or equal to this value. The default value of this object is
“Warning.”
Note: This severity applies to all entries. See FcEventSeverity in Table 11 on page 285.
trapRegRowState
OID 1.3.6.1.3.94.2.3.1.4
Description Specifies the state of the row.
Note: This entry always returns rowActive and allows for read-only.
OID 1.3.6.1.3.94.3
Description This is the revision number for this MIB. The format of the
revision value is as follows:
0 = High order major revision number
1 = Low order major revision number
2 = High order minor revision number
3 = Low order minor revision number
The value is stored as an ASCII value. The following is the
current value of this object:
0 = “0”
1 = “3”
2 = “0”
3 = “0”
This defines a revision of 03.00.
Unsupported Tables
HP does not support the following:
■ Connectivity Unit Port Statistics Hub Table
■ Connectivity Unit Port Statistics Fabric Table
■ Connectivity Unit Port Statistics SCSI Table
■ Connectivity Unit Port Statistics LAN/WAN Table
Related Traps
connUnitStatusChange
Enterprise fcmgmt
Variables connUnitStatus, connUnitState
Description The overall status of the connectivity unit has changed.
Recommended severity level (for filtering): alert.
connUnitDeletedTrap
Enterprise fcmgmt
Variables connUnitId
Description A connUnit has been deleted from this agent.
Recommended severity level (for filtering): warning.
connUnitEventTrap
Enterprise fcmgmt
Variables connUnitEventId, connUnitEventType,
connUnitEventObject, connUnitEventDescr
Description An event has been generated by the connectivity unit.
Recommended severity level (for filtering): info.
connUnitSensorStatusChange
Enterprise fcmgmt
Variables connUnitSensorStatus
connUnitPortStatusChange
Enterprise fcmgmt
Variables connUnitPortStatus, connUnitPortState
Description Overall status of the connectivity unit changed.
Recommended severity level (for filtering): alert.
Switch Variables
MIB variables that assist in monitoring or modifying the status/state of switches
are in the following tables or groups:
■ Connectivity Unit Table, page 288
■ Connectivity Unit Revisions Table, page 299
■ FIBRE-CHANNEL-FE-MIB Organization, page 98
■ FCFABRIC-ELEMENT-MIB Organization, page 133
■ Flash Administration, page 215
Sensor Variables
MIB variables that assist in monitoring or modifying the status/state of fans,
power supplies, and temperature are in the following tables or groups:
■ Connectivity Unit Sensor Table, page 301
■ swNumSensors, page 219
Port Variables
MIB variables that assist in monitoring or modifying ports are in the following
tables or groups:
Event Variables
MIB variables that assist in monitoring or modifying events are in the following
tables or groups:
■ Connectivity Unit Event Table, page 318
■ Event Group, page 243
ISL Variables
■ Connectivity Unit Link Table, page 323
■ Fabric Group, page 224
MIB OIDs
The following matrix allows you to identify a MIB object name according to its
related OID.
Table 14: MIB Object Name/OID Matrix (Sheet 1 of 24)
Page
MIB Object Name OID No.
iso 1 40
org 1.3 40
dod 1.3.6 40
internet 1.3.6.1 40
directory 1.3.6.1.1 40
mgmt 1.3.6.1.2 40
mib-2 1.3.6.1.2.1 40
fcFeMIB 1.3.6.1.2.1.75 98
fcFeMIBObjects 1.3.6.1.2.1.75.1 98
fcFeConfig 1.3.6.1.2.1.75.1.1 98
fcFeFabricName 1.3.6.1.2.1.75.1.1.1 104
fcFeElementName 1.3.6.1.2.1.75.1.1.2 105
fcFeModuleCapacity 1.3.6.1.2.1.75.1.1.3 105
fcFeModuleTable 1.3.6.1.2.1.75.1.1.4 105
fcFeModuleEntry 1.3.6.1.2.1.75.1.1.4.1 105
fcFeModuleIndex 1.3.6.1.2.1.75.1.1.4.1.1 106
fcFeModuleDescr 1.3.6.1.2.1.75.1.1.4.1.2 106
fcFeModuleObjectID 1.3.6.1.2.1.75.1.1.4.1.3 106
fcFeModuleOperStatus 1.3.6.1.2.1.75.1.1.4.1.4 107
fcFeModuleLastChange 1.3.6.1.2.1.75.1.1.4.1.5 107
fcFeModuleFxPortCapacity 1.3.6.1.2.1.75.1.1.4.1.6 107
fcFeModuleName 1.3.6.1.2.1.75.1.1.4.1.7 107
fcFxPortTable 1.3.6.1.2.1.75.1.1.5 108
fcFxPortEntry 1.3.6.1.2.1.75.1.1.5.1 108
fcFxPortIndex 1.3.6.1.2.1.75.1.1.5.1.1 108
A Group 80
Accounting Group 120, 159 Neighbor Table 81
Address Translation End Device
Group 55 Group 258
Table 55 Rls Table 258
audience 34 Environment Sensor Table 220
authorized reseller, HP 38 equipment symbols 38
Error Group 118, 156
C Event
Group 243
Capability Group 128, 159
Table 243
Configuration Group 104, 139
Connectivity Group 287
F
Connectivity Unit
Port Statistics FabricTable 354 Fabric Group 224
Port Statistics Hub Table 354 Fabric Watch
Index
H S
help, obtaining 38 Scalar Objects 104, 139
Scalars 346