TEST REPORT
Issued To: Name of Work: --
M/s
TEST REPORT
Supplement Test Report to Report No. PTL23D1001-01, dated 18/04/2023
Issued To: Name of Work: --
M/s Awasthi Tubewell Company
Kamlanagar, Collectorganj Fatehpur – 212601 (U.P.)
Customer Ref. No. & Date: ATC/Testing/RM001/23-24,
Test Report No.: PTL23D1001-01S
Dated: 10.04.2023
Date of Issue of Test Report: 09/05/2023 Name of Agency: M/s Awasthi Tubewell Company
Date of Receipt of sample: 10/04/2023 Contract Bond No.: --
Date of Start of Test: 11/04/2023 Sampling Done By: Customer
Date of Completion of Test: 09/05/2023 Sample Condition: Satisfactory
Sample Description: O.P. Cement 43 Grade Test(s) performed at: Lab
“Ambuja” Customer Name/ Contact: Mr. Ankit/9415033015
Addition to, Deviation or Exclusion from the Method(s): None
Discipline: Mechanical Group: Building, Infrastructure & Construction Materials
Page 1 of 1
S. Requirements as per
Test Parameter (s) Test Method Observed Value
No. IS: 269: 2015
Compressive Strength, N/mm²
1. IS 4031 (Part 6):1988, RA 2019
a) After 672±4h 47.5 43 - 58
***End-of-Test-Report***
Format No.: PTL/FTR-00
TEST REPORT
Issued To: Name of Work: --
M/s Awasthi Tubewell Company
Kamlanagar, Collectorganj Fatehpur – 212601 (U.P.)
Customer Ref. No. & Date: ATC/Testing/RM001/23-24,
Test Report No.: PTL23D1001-02
Dated: 10.04.2023
Date of Issue of Test Report: 24/04/2023 Name of Agency: M/s Awasthi Tubewell Company
Date of Receipt of sample: 10/04/2023 Contract Bond No.: --
Date of Start of Test: 11/04/2023 Sampling Done By: Customer
Date of Completion of Test: 24/04/2023 Sample Condition: Satisfactory
Test(s) performed at: Lab
Sample Description: Bricks 1st Class “GAGAN”
Customer Name/ Contact: Mr. Ankit/9415033015
Addition to, Deviation or Exclusion from the Method(s): None
Discipline: Mechanical Group: Building, Infrastructure & Construction Materials
Page 1 of 2
S. Observed Requirements as per
Test Parameter (s) Test Method
No. Value IS: 1077: 1992
Dimension, mm
Length of 20 Bricks IS 1077: 1992, 4580 4600±80
1.
Width of 20 Bricks RA 2021 2210 2200±40
Height of 20 Bricks 1420 1400±40
10.8
11.3
11.6 7.5 Min. for Class 7.5
2. Compressive Strength, N/mm² IS 3495(Part-1): 2019 10 Min. for Class 10
10.6 12.5 Min. for Class 12.5
11.8
Avg. 11.2
Format No.: PTL/FTR-00
Sample Description: Bricks 1st Class “GAGAN” Test Report No.: PTL23D1001-02
Page 2 of 2
S. Test Parameter (s) Test Method Observed Requirements as per
No. Value IS: 1077: 1992
14.8
13.0
14.4 20 Max. for upto Class 12.5
Water Absorption, %
3. IS 3495(Part-2): 2019 15 Max. for higher classes.
(by 24-hour water absorption test) 12.4
13.3
Avg. 13.5
Nil
Not more than “Moderate”
Nil for upto Class 12.5
4. Efflorescence IS 3495(Part-3): 2019 Slight Not more than “Slight” for
Slight higher classes.
Nil
***End-of-Test-Report***
Format No.: PTL/FTR-00
TEST REPORT
Issued To: Name of Work: --
M/s Awasthi Tubewell Company
Kamlanagar, Collectorganj Fatehpur – 212601 (U.P.)
Customer Ref. No. & Date: ATC/Testing/RM001/23-24,
Test Report No.: PTL23D1001-03
Dated: 10.04.2023
Date of Issue of Test Report: 22/04/2023 Name of Agency: M/s Awasthi Tubewell Company
Date of Receipt of sample: 10/04/2023 Contract Bond No.: --
Date of Start of Test: 11/04/2023 Sampling Done By: Customer
Date of Completion of Test: 22/04/2023 Sample Condition: Satisfactory
Test(s) performed at: Lab
Sample Description: Coarse Aggregate 10mm
Customer Name/ Contact: Mr. Ankit/9415033015
Addition to, Deviation or Exclusion from the Method(s): None
Discipline: Mechanical Group: Building, Infrastructure & Construction Materials
Page 1 of 1
S. Observed Requirements as per
Test Parameter (s) Test Method
No. Value IS: 383: 2016
Sieve Analysis, % passing through IS
Sieve size, mm
12.5 100 100
1. 10.0 IS 2386(Part-1):1963, RA 2021 96.7 85 – 100
4.75 13.2 0 – 20
2.36 2.9 0–5
Combined Flakiness and Elongation By Calculation
2. 24.8 40 Max.
Index, % (IS 383: 2016 / IS 2386(Part-1)
3. Specific Gravity IS 2386(Part-3):1963, RA 2021 2.61 2.1 – 3.2
4. Water Absorption, % IS 2386(Part-3):1963, RA 2021 0.40 5 Max.
5. Compacted Bulk Density, kg/l IS 2386(Part-3):1963, RA 2021 1.55 --
6. Aggregate Impact Value, % IS 2386(Part-4):1963, RA 2021 20.8 30 Max.
30 Max. for wearing surfaces
7. Crushing Value, % IS 2386(Part-4):1963, RA 2021 23.7 45 Max. for non-wearing
surfaces
8. Soundness (by Na2SO4), % IS 2386(Part-5):1963, RA 2021 0.24 12 Max.
***End-of-Test-Report***
Format No.: PTL/FTR-00
TEST REPORT
Issued To: Name of Work: --
M/s Awasthi Tubewell Company
Kamlanagar, Collectorganj Fatehpur – 212601 (U.P.)
Customer Ref. No. & Date: ATC/Testing/RM001/23-24,
Test Report No.: PTL23D1001-04
Dated: 10.04.2023
Date of Issue of Test Report: 22/04/2023 Name of Agency: M/s Awasthi Tubewell Company
Date of Receipt of sample: 10/04/2023 Contract Bond No.: --
Date of Start of Test: 11/04/2023 Sampling Done By: Customer
Date of Completion of Test: 22/04/2023 Sample Condition: Satisfactory
Test(s) performed at: Lab
Sample Description: Coarse Sand (Stone Dust)
Customer Name/ Contact: Mr. Ankit/9415033015
Addition to, Deviation or Exclusion from the Method(s): None
Discipline: Mechanical Group: Building, Infrastructure & Construction Materials
Page 1 of 2
S. Requirements as per
Test Parameter (s) Test Method Observed Value
No. IS: 383: 2016
Sieve Analysis, % passing through IS
Zone-II
Sieve size, mm
10 100 100
4.75 94.2 90-100
Sample Description: Coarse Sand (Stone Dust) Test Report No.: PTL23D1001-04
Page 2 of 2
S. Requirements as per
Test Parameter (s) Test Method Observed Value
No. IS: 383: 2016
Deleterious Material
a) Material Finer Than 75µ IS sieve, % IS 2386(Part-1):1963, RA 2021 3.60 15.00 Max.
7. b) Clay Lumps, % IS 2386(Part-2):1963, RA 2021 0.03 1.00 Max.
c) Coal & Lignite, % IS 2386(Part-2):1963, RA 2021 Nil 1.00 Max.
d) Total Deleterious Material, % By Calculation (IS 383:2016) 0.03 2.00 Max.
8. Soundness (by Na2SO4), % IS 2386(Part-5):1963, RA 2021 2.32 10 Max.
9. Fineness Modulus IS 6461(Part-1) 1972, RA 2021 2.87 --
10. Voids (Porosity) IS 2386(Part-3):1963, RA 2021 34.8 --
The colour of sample
Lighter than Std. solution should be
11. Organic Impurities IS 2386(Part-2):1963, RA 2021
Solution lighter than std.
Tannic acid solution.
***End-of-Test-Report***