0% found this document useful (0 votes)
42 views1 page

FLRYWK Cables

Siechem introduced that "Siechem FLRYWK Cables" reviewed by Rohit damodaran. It is low-tension electric wires and cables for automobiles. To know more about Siechem's wires and cables visit: www.siechem.com

Uploaded by

Krista
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
42 views1 page

FLRYWK Cables

Siechem introduced that "Siechem FLRYWK Cables" reviewed by Rohit damodaran. It is low-tension electric wires and cables for automobiles. To know more about Siechem's wires and cables visit: www.siechem.com

Uploaded by

Krista
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Siechem FLYWK&FLRYWK RoHS

Wires
Wires&&Cables
Cables

Application Product Construction Technical Data


ü Low-tension electric wire for Automobiles. ü Conductor : Soft-annealed electrolytic Copper ü Temperature Range :
ü Used in Motorcycles and other motor vehicles for E-Cu ETP1 according to DIN 13602, bare conductor - 500C to +1050C (3000 Hours)
starting, charging, lighting, signal and instrument ü Insulation : Plasticized PVC, heat and cold resistant, ü Test Voltage: 3kV (r.m.s.) for cables < 0.5 mm2
panel circuits. lead free 5kV (r.m.s.) for cables ≥ 0.5 mm2
ü Colour : As per customer order. ü FL : Automotive cable
ü Single core ü Y : PVC
2D View ü WK : Heat and cold resistant
ü Standard: Bosch 5998342...

Features
FLYWK &
ü Flame retardant FLRYWK ISO ISO OHSAS
IATF
ü Highly resistant against acids, lyes, Petrol
9001 14001 16949 18001
and diesel.
ü Flexible conductors with PVC Thin wall insulation
with increased mechanical strength.
ü Extra flexibility.

Conductor Construction Cable Max.


Part Insulation Current Standard
Overall Carrying Conductor
Number Nominal No. of Diameter of Conductor Wall Thickness Weight Length*
Diameter Capacity Resistance
Cross- Strands Single wire Diameter Nom. Approx.
Max. at 200C
Section max. Nom.
mm2 nos. mm mm mm mm kg/km Amps Ω/km mtrs
83606XX * 0.5 16 0.2 1.0 0.28 1.6 6 13 37.1 500
83610XX 0.75 24 0.2 1.2 0.60 2.5 33 19 24.7 500
83613XX 1 32 0.2 1.4 0.30 2.1 57 21 18.5 500
83616XX 1.5 30 0.25 1.7 0.30 2.4 111 27 12.7 500
83616XX 2.5 50 0.25 2.1 0.70 3.7 278 39 7.6 500

Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.
Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11
Chocolate - 12 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 20 Pink - 21

0 0
ü Current Carrying capacity given is for the maximum conductor operating temperature of 105 C and ambient air temperature of 40 C.
ü * Other length as per Customer order.

Catalogue
No

836

Siechem Wires & Cables Meet EU RoHS Directive


Lead Hg Cd Cr6+ PBB PBDE
Free Free Free Free Free Free

www.siechem.com
86
All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and
Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.