PaxScan® 4336R

Flat Panel Detector

Product Description

The PaxScan 4336R is the first ruggedized portable


X-ray flat panel detector designed formobile digital
radiographic X-ray systems to fit existing 14"x17"
standard bucky trays. Based upon the new Gigabit
Ethernet interface, images are displayed on a user-
supplied workstation.

Technical Specifications Software


Receptor Type . . . . . . . . . . . . . . . . . Amorphous Silicon Technology The software release includes ViVA™, a basic application for image
acquisition and viewing on an end-user workstation or laptop
Conversion Screen . . . Direct Deposit CsI, Detached CsI, DRZ Plus running Microsoft® Windows™. The developer’s software package
Pixel Area Total . . . . . . . 42.7 (v) x 35.6 (h) cm (16.8 x 14.0 inch) includes a “Virtual Command Processor” software interface that
Active . . . . . . 42.4 (v) x 35.3 (h) cm (16.7 x 13.9 inch) performs detector calibration, detector set-up, image acquisition,
and image corrections. ViVA™ includes file type translators for .viv,
Pixel Matrix Total . . . . . . . . . . . . . . . . . . . . . . . 3,072 (v) x 2,560 (h) .raw, .jpg, and .bmp file formats. Windows® XP and Windows® 7 (32
Active . . . . . . . . . . . . . . . . . . . . . . 3,052 (v) x 2,540 (h) bit) compatible.
Pixel Pitch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139 m Computer Requirements
Limiting Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.6 lp/mm RAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.00 GB
Image Quality GADOX (typical) DD/CSI (typical) CPU . . . . . . . . Pentium dual core running @ 2.0 GHz or equivalent
DQE @ 0 lp/mm 33%* 70%* Power
DQE @ 1 lp/mm 24%* 54%*
DQE @ 2 lp/mm 15%* 42%* Power Dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 watts (cont.)
DQE @ 3 lp/mm 7%* 26%* 35 watts (max.)
DQE @ Nyquist 4%* 15%* I/O Interface Box . . . . . . . . . . . . . . . . . . . . 100 - 240 VAC, 47 - 63 Hz
MTF @ 1 lp/mm 53% 57% (Up to 9m away from panel)
MTF @ 2 lp/mm 20% 27%
MTF @ 3 lp/mm 9% 13% Mechanical
MTF @ Nyquist 5% 10% Weight (includes battery) . . . . . . . . . . . . . . . . . . . . . 8.6 lbs. (3.9 kg)
Sensitivity 0.412 LSB/nGy 0.825 LSB/nGy
Housing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Aluminum
Energy Range Standard . . . . . . . . . . . . . . . . . . . . . . . 40 - 150 kVp
Sensor Protection Material . . . . Carbon fiber plate and aluminum
Scan Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Progressive
Environmental
Data Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Gigabit Ethernet
Shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . High-shock tolerance
A/D Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-bit
Water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IPX1 Water Resistant
Cycle Time (minimum / standard) . . . . . . . . . . . . . . . . . . . 4 / 5 sec.
Temperature Range - Operating (at back cover) 10°C to 35°C (max.)
Exposure Control Inputs: . . . . . . . . . . . . Prepare, Expose-Request (Ambient) - Storage . . . . . . . . . . . . . . . . . . . . . . . -20°C to +70°C
Outputs: . . . . . . . . . . . . . . . . . . . . . . . . Expose-OK Humidity - Operating & Storage (non-condensing) . . 10% to 90%

Patient Contact Atmospheric Pressure - Operating & Storage . . 70 kPa to 106 kPa
Weight Limit Regulatory
Uniform load across entire carbon fiber surface . . . . . . . 150 kg U.S. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ANSI/AAMI ES60601-1:2005
Concentrated 40mm diameter load at the center . . . . . . 100 kg Canada . . . . . . . . . . . . . . . . . . . . . . . . . . . CAN/CSA C22.2 No. 60601-1:08
EU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IEC/EN 60601-1:2005
* Without enclosure

®PaxScan is a Registered Trademark of Varex Imaging Corporation


134772-000 Rev B 08/17 Copyright © 2017, Varex Imaging Corporation. All Rights Reserved.

1
PaxScan® 4336R
Flat Panel Detector
Dimensions are for reference only
Dimensions are in mm [inches]

2 Denotes Approximate Center of Gravity

3 Active Area Dimension

4 Top Surface of Active Area

5 Hybrid Cable (Approximate Ø 9.5mm)

Manufactured by Varex Imaging Corporation

Specifications subject to change without notice.

Salt Lake City, UT 1-801-972-5000


Note: All Varex Imaging Amorphous Silicon Receptors are
Charleston, SC 1-843-767-3005 designed to be integrated into a complete X-ray system by a
qualified system integrator. The system Integrator is responsi-
www.vareximaging.com ble for obtaining FDA clearance for medical use.