Access Control

SiPass integrated
Release Notes
MP 2.95

A6V11170897 Smart Infrastructure

28.09.2023
Copyright

Copyright
Technical specifications and availability subject to change without notice.
We reserve all rights in this document and in the subject thereof. By acceptance of
the document the recipient acknowledges these rights and undertakes not to
publish the document nor the subject thereof in full or in part, nor to make them
available to any third party without our prior express written authorization, nor to
use it for any purpose other than for which it was delivered to him.
Edition: 28.09.2023
Document ID: A6V11170897

© Siemens 2023

2 | 38 A6V11170897
Table of Contents

1 Introduction ................................................................................................... 5
1.1 What this document covers ............................................................................. 6
1.2 Ordering .......................................................................................................... 6
2 Important Release Information .................................................................... 7
2.1 Security Recommendations ............................................................................ 7
2.1.1 Installing SiPass integrated on a Public Domain ............................. 7
2.1.2 Reducing Security Risks with Anti-Virus Software .......................... 7
2.1.3 Physical and Environmental Security .............................................. 7
2.2 Windows Patches and Hot Fixes .................................................................... 8
2.3 Maintenance Support ...................................................................................... 8
3 New Features in SiPass MP 2.95 ................................................................. 9
3.1 Installer Prerequisites Validation ..................................................................... 9
3.2 STid Secure Common Protocol (SSCPv2) ..................................................... 9
3.3 SMTP (Azure) for Modern Authentication ....................................................... 9
3.4 SiPass integrated RESTful HR API................................................................. 9
3.5 Support for Remote SQL "alias" Domain Names .......................................... 10
4 SiPass integrated Installation Compatibility ............................................ 11
4.1 License .......................................................................................................... 11
4.1.1 LMS Version .................................................................................. 11
4.2 SiPass integrated Server .............................................................................. 11
4.3 SiPass integrated Client ................................................................................ 12
4.4 SiPass integrated Web Client ....................................................................... 12
4.5 Microsoft SQL Server .................................................................................... 12
4.6 SiPass integrated Sync Agent ....................................................................... 13
4.7 .NET Framework ........................................................................................... 13
4.8 Installation Requirements .............................................................................. 13
4.8.1 Prerequisites .................................................................................. 13
4.9 System Compatibility ..................................................................................... 15
4.9.1 Firmware ........................................................................................ 15
4.9.2 Hardware ....................................................................................... 15
4.9.2.1 Controllers ................................................................................ 15
4.9.2.2 Door Control ............................................................................. 15
4.9.2.3 I/O ............................................................................................. 16
4.10 API / HLI Compatibility .................................................................................. 16
4.10.1 HR-API Interface ............................................................................ 16
4.10.2 Management / Enterprise Station API ........................................... 16
4.10.3 OPC A&E Server Interface ............................................................ 17
4.10.4 SiPass integrated with Siveillance VMS ........................................ 17
4.11 Video Management System .......................................................................... 17
4.12 Directly Connected IP Camera Compatibility ................................................ 17
4.13 Intrusion Panel Compatibility ......................................................................... 17
4.14 Network Communication ............................................................................... 18
4.15 Communication Encryption among SiPass integrated Components ............ 18

A6V11170897 3 | 38
4.16 Modem Compatibility .....................................................................................19
4.17 Card Printer Compatibility .............................................................................19
4.18 Mifare Classic/ DEsfire EV1 Card Encoding (while printing) .........................20
4.19 Enrolment Reader Compatibility ...................................................................20
4.19.1 USB Enrolment readers .................................................................20
4.20 Card Format Compatibility.............................................................................21
4.20.1 Reader Connection Types .............................................................21
4.20.2 Siemens Proprietary Card Formats ...............................................21
4.20.3 Proximity Formats ..........................................................................21
4.20.4 Smart Card Formats ......................................................................21
4.21 Card Reader Compatibility ............................................................................21
4.21.1 Readers Supporting the DESFire EV1 Card Technology ..............21
4.21.2 HID Proximity, iCLASS (SE), iCLASS Seos and Mifare
Classic/DESFire .............................................................................22
4.21.3 HID Readers for Siemens Sites .....................................................23
4.22 Card Technology Compatibility .....................................................................24
4.22.1 Formats supported by All HID Prox Technology ...........................24
4.23 TBS 3D Enroll ................................................................................................25
4.24 Granta MK3 Reader PIN Pad Type Compatibility .........................................25
4.25 Signature Capture Tablet Compatibility ........................................................26
4.26 Messaging System Compatibility ..................................................................26
4.27 Server Redundancy .......................................................................................26
4.28 Offline Door System ......................................................................................26
4.29 Identity Management .....................................................................................27
4.30 Virtualization ..................................................................................................27
5 SiPass integrated Server, Configuration Client and Operation Client ..28
5.1 Fixed Issues ..................................................................................................28
5.2 Known Issues and Limitations .......................................................................31
5.2.1 SiPass integrated Firmware ...........................................................31
5.2.2 Configuration Client - Card Template ............................................32
6 SiPass integrated Web Client ....................................................................33
6.1 Fixed Issues ..................................................................................................33
6.2 Known Issues and Limitations .......................................................................33
6.2.1 Known General Issues ...................................................................33
6.2.2 Known Issues for Live Alarm .........................................................33
6.2.3 Known Issues for Cardholder/Visitor Application ...........................33
6.2.4 Known Issues for Page Customization ..........................................34
6.2.5 Known Issues for Venue Booking ..................................................34
6.2.6 Known Issues for Localization .......................................................34
6.2.7 Limitations ......................................................................................35
7 DesigoCC Integration ..................................................................................37

4 | 38 A6V11170897
Introduction 1
What this document covers

1 Introduction
SiPass® integrated is a powerful and extremely flexible access control system that
provides a very high level of security without compromising convenience and ease
of access for system users. It is also possible to use SiPass integrated as a
security management station (SMS) that integrates access control, intrusion
detection and video surveillance into a single system. Some of the noticeable
features include:
● Design to fit into a state-of-the-art IT environment
● Modular structure and scalability for keeping pace with changing needs of any
organization
● Intuitively designed software that is easy to use and administer
● Support for broad range of readers, various technologies and manufacturers
● Support for offline doors – SALTO, OSS-SO
● Wireless locking system, APERIO, utilizing the powerful ACC-AP controller
● Touchless Biometric Systems integration with web client enrolment
● SiPass integrated -- Opening doors to a secure environment.

NOTICE
High Risk System shall mean a device or system that requires enhanced safety
functionalities such as fail-safe or fault-tolerant features to maintain a safe state
where it is reasonably foreseeable that failure of the device or system could lead
directly to death, personal injury, or catastrophic property damage. High Risk
Systems may be required in critical infrastructure, direct health support devices,
aircraft, train, boat, or vehicle navigation or communication systems, air traffic
control, weapons systems, nuclear facilities, power plants, medical systems and
facilities, and transportation facilities.
High Risk Use. Customer acknowledges and agrees that
(i) the Offerings are not designed to be used for the operation of or within a High
Risk System if the functioning of the High Risk System is dependent on the
proper functioning of the Offering
(ii) the outcome from any processing of data through the use of the Offering is
beyond Siemens’ control. Customer shall indemnify Siemens, its Affiliates, its
subcontractors, and their representatives, against any third-party claims,
damages, fines and cost (including attorney’s fees and expenses) relating in any
way to any use of an Offering for the operation of or within a High Risk System.

A6V11170897 5 | 38
1 Introduction
What this document covers

NOTICE
This Siemens system is not designed to be fault tolerant and is not intended to be
used in hazardous or high risk environments or systems that require fail safe
operations in which the failure, or interruption to normal operations of the system,
could lead directly to death, personal injury or damage to the environment. High
risk environments may include, without limitation, communication systems, fire
control and release systems, personal safety systems, air travel, space travel,
fire-fighting, police operations, power plant operation, military operations, rescue
operations, hospital or medical operations, nuclear facilities or equipment, or
anywhere that requires fault tolerance. High Risk System means a device or
system that requires enhanced safety functionalities such as fail-safe or fault-
tolerant features to maintain a safe state where it is reasonable foreseeable that
failure of the device or system could lead directly to death, personal injury, or
catastrophic property damage.

1.1 What this document covers


This document details the introduction to the new user interface, security features,
information on supported technology, compatibility with other devices and the
important information that users need to be aware of when ordering, installing and
troubleshooting.

1.2 Ordering
To order the SiPass integrated software, contact the Siemens Sales Department in
your region.

6 | 38 A6V11170897
Important Release Information 2
Security Recommendations

2 Important Release Information


Before installing SiPass integrated, refer to the SiPass integrated Installation Guide
that contains all the necessary procedures to install and upgrade the software, and
other associated hardware and software components.
To ensure setting up the system with highest level of security, follow the
recommendations given in the SiPass integrated Security Recommendations.
Both the documents are available in the software bundle.

2.1 Security Recommendations


This section details important security recommendations regarding the installation
of SiPass integrated on public domains. It also deals with the important issue of
protecting your software system from virus infections.

2.1.1 Installing SiPass integrated on a Public Domain


Users please note that installing SiPass integrated on a public domain presents
vulnerabilities (e.g., being infected by computer viruses) like any application
running on a Windows environment.
If SiPass integrated, controllers or an integrated system are to be installed on a
public domain, it is recommended that a dedicated network (like a VLAN) be used
for optimal security. Telnet and SSH on the ACC and ACC-AP controllers should
be disabled after installation. Further, installation of the server and the client as
dedicated applications on the computer is advisable.
SiPass integrated users are also advised to lockdown USB ports on the computers
where SiPass integrated has been installed. Further, it is recommended that client
computers for non-administrator operators should be locked down.

2.1.2 Reducing Security Risks with Anti-Virus Software


It is recommended that all SiPass integrated operators install and run an Anti-Virus
or Virus Scan application to protect your computer from viruses, and other security
threats that can compromise the performance of the system. SiPass integrated has
been tested with the TREND MICRO Office Scan software.
As there are numerous brands of anti-virus software available in the market, it is
recommended that you first investigate the source of software before downloading
and installing it. It is advisable that you choose a virus scanner that best meets the
needs of yourr particular software environment. It is also important that you test
your anti-virus application with SiPass integrated before going live to ensure that
the anti-virus application does not impact the performance of your security
management.

2.1.3 Physical and Environmental Security


The following restrictions apply with regard to the physical protection of the SiPass
integrated system against unauthorized or malicious use:
● The equipment room in which the SiPass integrated is installed must be locked
and access must be controlled by means of organizational access restrictions.
● All publicly accessible data transmission lines must be protected against
unauthorized access.
● Serial interfaces and cabling must be physically protected when any of these
components are located in a publicly accessible area.
● The serial end points must be protected by physical, organizational or logical
means. Only connect approved devices to these interfaces. The interface must
be deactivated if no devices are connected.

A6V11170897 7 | 38
2 Important Release Information
Windows Patches and Hot Fixes

● Define and implement processes to grant and revoke physical access.


● Additional controls – such as site protection, additional restrictive access
control for the building and rooms, security personnel, or monitoring – can help
to improve the physical security of the system.

2.2 Windows Patches and Hot Fixes


It is expected that SiPass integrated will continue to operate as normal if you
automatically update your PC with any updates or patches provided by Microsoft.
However, some exceptional changes made by Microsoft to their operating system
may cause unexpected results. In these instances, report your problem to your
local support representative and the issue will be investigated as soon as possible.

2.3 Maintenance Support


The most recent market release(s) are classified as Maintained Versions. For
these releases Hotline Support, Service Releases and Software Updates (For
example, new extension modules) are available.
Previous market releases are classified as Supported Versions for which Hotline
Support and Service Releases are available.
Older market releases are classified as Retired Versions. This means that
customer support is no longer obligated to answer support calls. To get support,
the customer will have to upgrade to a newer market release. Activating the license
for a maintained version will start the first year of SUR support. If the customer,
then purchases a further 2 years SUR they will remain supported.

Market Release Maintained Supported Retired Version


Version Version
SiPass integrated X
MP2.95
SiPass integrated X
MP2.90
*SiPass integrated X
2.85
SiPass integrated X
MP2.80 and earlier

*SiPass integrated MP2.85 localised versions will be supported until a replacement


is available for the language in MP2.95. Once the localised version is available in
MP2.95, no further support calls will be possible with the MP2.85 except for
upgrade queries.

8 | 38 A6V11170897
New Features in SiPass MP 2.95 3
Installer Prerequisites Validation

3 New Features in SiPass MP 2.95

3.1 Installer Prerequisites Validation


SiPass integrated MP 2.95 installer has been enhanced with a new dialog box to
validate the prerequisites and therefore this makes the installation smooth. The
installer does not proceed if any of the prerequisites are not met.
The following prerequisites are validated during installation:
● File Execution Permission
● Registry Access
● Folder Access
● Port Access
● SQL User Rights

3.2 STid Secure Common Protocol (SSCPv2)


SiPass integrated supports SSCPv2 (STid Secure Common Protocol) is a reader
RS485 protocol which comes with high security standard (ANSSI) to enable
security from reader to ACC AP (DRIe).
For information on configuring the reader, refer “Configuring STid Secure Common
Protocols (SSCPv2) Reader” section in the Configuration Client User Guide.

3.3 SMTP (Azure) for Modern Authentication


SiPass integrated MP 2.95 has been enhanced to support SMTP Azure modern
authentication mechanism. SiPass integrated is moving to modern authentication
to avoid surface attacks. Commissioning engineers shall be able to configure
Office 365 to trigger email notifications. For information on configuring Office 365,
refer to “SiPass integrated SMTP (Azure) Configuration Guide .pdf” supplied with
this package.

3.4 SiPass integrated RESTful HR API


● External Access Privilege configuration feature has been introduced to provide
bi-directional synchronization of Access Privileges between SiPass integrated
and third-party applications/Security Manager. SiPass integrated HR RESTful
API provides an option to create/update/delete Access Groups of type External.
Existing API end point requests has been modified to achieve these
functionalities. Create/Update/Delete Access Groups of type “External” and
assigning those privileges to Cardholders are introduced as part of this feature.
For more information, refer to the “SiPass integrated Operation Client User
Guide”.
● SiPass integrated HR RESTful API provides an option to create/update/delete
the cardholders/images in bulk. New API end points has been provided to
achieve these functionalities.
● For more information, refer to “RESTful HR API Release Notes.pdf” supplied
with this package. For information on how to consume the updated endpoints,
refer to "RESTful HR API Specification Guide.pdf" and "RESTful HR API Object
Model Guide.pdf" provided with this package.

A6V11170897 9 | 38
3 New Features in SiPass MP 2.95
Support for Remote SQL "alias" Domain Names

3.5 Support for Remote SQL "alias" Domain Names


From SiPass integrated MP 2.95 onward, CNAME as a SQL instance name is
supported.
A Canonical Name (CNAME) record is a type of resource record in the Domain
Name System (DNS) that maps one domain name (an alias) to another (the
canonical name).

10 | 38 A6V11170897
SiPass integrated Installation Compatibility 4
License

4 SiPass integrated Installation


Compatibility
The following tables outline the components that have been tested with this version
of SiPass integrated.

4.1 License
“SiPass integrated License” is a subscription-based service managed by a
central tool - Siemens License Management System (LMS).

If you do not have a SiPass integrated Order a new one for MP 2.95
LMS license
If you have a LMS license for MP Use the existing license for SiPass
2.80/2.85/2.90 and are upgrading to MP integrated MP 2.95 installation, as long
2.95 as the license subscription is not
expired. LMU must update to LMU 2.7.
If you have a License for SiPass Order a upgrade license to operate
integrated 2.76 and lower SiPass 2.95

● Your existing license will be modified and applied to the new License
Management Service (LMS), from which you can activate your product.
● Depending on the costs paid for the previous license, the new MP 2.95 license
will be issued for the standard upgrade fee (or any other amount as per your
current agreement).
● SiPass integrated considers each Management-API (RESTful) connection as a
workstation and the user needs to purchase a separate license for each extra
connection.
Contact Siemens Support in your region for help with this matter.

Note:
SiPass integrated is always by your side and will keep working even when the
subscription expires. However, it is recommended to renew your subscription as
soon as possible to stay up to date on the latest product features, security
updates and access to support.
When your subscription is about to expire, the status bar in SiPass integrated
Configuration Client and Operation Client will start showing a reminder 7 days
before the expiry. You can also check the subscription status any time by clicking
Help > About from the top menu bar.
Contact Siemens Support in your region for help with renewing the subscription.
For details on maintenance support, refer Maintenance Support [➙ 8].

4.1.1 LMS Version


LMS 2.7 is supported for SiPass integrated MP 2.95.

4.2 SiPass integrated Server


Windows 10 Windows Server 2019
(Professional, Enterprise) (64-bit)

Windows 11 Windows Server 2022


(Professional, Enterprise) (64-bit)

A6V11170897 11 | 38
4 SiPass integrated Installation Compatibility
SiPass integrated Client

Some additional configuration settings are required to ensure that the specified
versions of Windows operating systems operate correctly with SiPass integrated.
For further information, see Appendix - Windows Settings in the SiPass integrated
Installation Guide for this market package of SiPass integrated.

4.3 SiPass integrated Client


Windows 10 Windows Server 2019
(Professional, Enterprise) (64-bit)

Windows 11 Windows Server 2022


(Professional, Enterprise) (64-bit)

Only ONE LANGUAGE VERSION must be used for SiPass integrated. Using
more than one language is not supported and might result in malfunction. Some
additional configuration settings are required to ensure that the specified versions
of Windows operating systems operate correctly with SiPass integrated. For
further information, see Appendix - Windows Settings in the SiPass integrated
Installation Guide for this market package of SiPass integrated.

4.4 SiPass integrated Web Client


From SiPass integrated MP 2.95 onward, Activity Feed and Area Monitoring
features are unavailable.

4.5 Microsoft SQL Server


Microsoft SQL Server is the system that meets the numerous and complex
database needs of SiPass integrated. Microsoft SQL Server provides the level of
software security necessary to safeguard the records created and modified in
SiPass integrated.
The following table indicates the supported SQL Server software on which SiPass
integrated will run:

SQL 2022 Express SQL 2022 SQL 2022 Enterprise


SQL 2019 Express SQL 2019 SQL 2019 Enterprise

The following information must be noted carefully:


● If there are no SQL server versions installed on the computer where SiPass
integrated is installed, a runtime version of Microsoft SQL Server 2022 Express
will be installed.
● Sites with multiple clients and higher activity (for example, a large number of
doors / cardholders / or event transactions, involving more than 5 clients, 100
doors, or 10000 cardholders) are recommended to purchase a higher
performance version of SQL optimized for both scalability and performance.
See the Microsoft website for more information regarding SQL versions
and performance. Failure to install the appropriate version of SQL Server may
have an adverse impact upon the performance of SiPass integrated.

12 | 38 A6V11170897
SiPass integrated Installation Compatibility 4
SiPass integrated Sync Agent

NOTICE

If you have unsupported version of Microsoft SQL Server, uninstall it first as it


may affect the installation of Microsoft SQL Server 2022 Express. Restart the
system after uninstallation.

For data privacy, during the upgrade of SiPass integrated, ensure that the "asco4"
database and “SiSuite.Access.UAM” database is removed from the unsupported
versions of SQL Server.
From SiPass integrated MP 2.95 onward, SQL Server 2022 will be installed only
in Windows authentication mode.

4.6 SiPass integrated Sync Agent


SiPass integrated Sync Agent 1.4 or higher is supported.

4.7 .NET Framework


The following .NET Framework version is tested to be compatible with SiPass
integrated:

.NET Framework Version 4.8

4.8 Installation Requirements

4.8.1 Prerequisites
Before installing SiPass integrated, ensure that the following prerequisites are
installed in the system.
● Browsers: Chrome and Firefox. Recommended browser versions are:
– Chrome greater than 103.0.5060.134
– Firefox 76.0.1
The following must be installed/uninstalled manually:
● License Management System (LMS) (Available in the Prerequisites folder in
the SiPass integrated software bundle)

NOTICE
If you are manually uninstalling, ensure that the installation folder, registry entries,
and other related services of the corresponding components are completely
removed. By default, the installation folder will be as follows:
RabbitMQ 3.12.0 - <Windows installation drive>\Program Files \RabbitMQ
Erlang OTP 25.3 - <Windows installation drive>\Program Files\Erlang OTP
If ERLANG OTP installed folder is not removed after uninstallation, it is required
to restart the machine and remove the folder again.
In prior version of SiPass integrated, while uninstalling, if the previous SiPass
integrated folder is still available, it will be automatically removed. Otherwise, an
error message will be thrown as Installer cannot delete a folder (Destination
path) from previous installation due to insufficient privileges. Do delete the
folder manually and continue with the installation.

A6V11170897 13 | 38
4 SiPass integrated Installation Compatibility
Installation Requirements

● WE Installation Helper R101 (for TBS Server and Terminal Enrollment)


● Enrollment Module 10 (for TBS USB Enrollment)

In the Enrollment Module 10 installation folder, navigate to the


Service>Settings>Public>Service.Enrollment.ini file. Ensure “Use Https” is set
as true and “Port” has the value 8282. Open
ServerCommunication.WebEdition.ini file, and map the EndpointIP as the IP
of the TBS Server. Restart the Enrollment Module 10 windows service.

The following components are installed automatically and must not be


uninstalled at any time to ensure uninterrupted operation of SiPass
integrated:
● .NET Framework 4.8
Note: Make sure to exit all .NET based applications before you install.
● Microsoft Command Line Utilities 15 for SQL Server (x64)
● Microsoft ODBC Driver for SQL Server (V17.10.4.1)
● Microsoft OLE DB Driver for SQL Server (v19.3.1)
● Microsoft SQL Express 2022 (Optional)
● Microsoft Visual C++ 2015-2022 Redistributable (x86 and x64)
● OPC Core Components Redistributable (v3.0.102)
● RabbitMQ 3.12.0
● Erlang OTP 25.3
● Microsoft Application Request Routing 3.0
● IIS URL Rewrite Module 2.0

You may be prompted to restart your computer during or after the installation.

NOTICE
The following components are not used by SiPass integrated MP 2.95 anymore
and can be manually uninstalled:
Apache Tomcat
Java 11
.NET Core 3.1.xx/.NET 6.0.xx
MonogDB 4.4.xx
Microsoft SQL Server Express LocalDB 2014/2019
Microsoft SQL Server 2017
Microsoft Visual C++ Redistributable 2015 – 2019
You may need to restart the computer after the uninstallation of the components.

14 | 38 A6V11170897
SiPass integrated Installation Compatibility 4
System Compatibility

4.9 System Compatibility

4.9.1 Firmware
AC5100 AC5102 ACC-AP
(ACC-020 / ACC-010) (ACC-G2) FW v6.0.3+4057
Version 2.76.46 FW v6.0.3+4057 App v3.0.4
App v3.0.4

AC5200 Granta Mk3 Granta Mk3 Backboard


(ACC lite) (ACC-Granta) Version 1.29
Version 2.70.52 Version 2.70.52

ADD51x0 (DRI) ADD51x0 ADS52x0* AFI5100 AFO5100


Version 3.67 (DRI-OSDP Crypto) (SRI) (IPM) (OPM)
Version 5.43 Version 3.29 Version 2.39 Version 1.19

ADE5300 AFO5200 ATI5100 MFI


(ERI) (8IO) (IAT-020) Version 1.44
Version 3.63 Version 1.09 Version 2.03

The ERI device supports only OSDP V1.


The DRI, ACC AP (DRIe), MFI and ACC G1/G2 devices support OSDP V2
(OSDP V1 + functions like secure channel encryption, smart card communication
and biometric reader support.)

4.9.2 Hardware

4.9.2.1 Controllers
AC5102 ACC-AP AC5100 AC5100
ACC-G2 ACC Revision 3 ACC Revision 2
ACC-020 ACC-010

AC5200 AC5200 AC5200 Granta Mk3


SR34i SR35i SR35i MkII Revision 1
Revision 1 Revision 1.4 Revision 2

4.9.2.2 Door Control


ADD51x0 ADS52x0 ADE5300 ATI5100 4322 4422 MFI
DRI SRI ERI IAT COTAG SWIPE
Revision Revision Revision Revision
D B A A

DC12 DC22 DC800 PD30/PD40


Rev. 05 Rev. 05 Rev. 04 Rev. 02

A6V11170897 15 | 38
4 SiPass integrated Installation Compatibility
API / HLI Compatibility

Aperio Hub and Locks


Aperio Hub Aperio Lock Aperio Lock Aperio Programming
AH30 E100 V3 AU100 V3 Application
FW Ver. 6.6.32718 * FW Ver. 3.7.1446 * FW Ver. 3.7.1446 * Ver. 18.0.4-e617dba **

* The above-mentioned Firmware Versions are tested to work with SiPass


integrated, and are not supplied or controlled by Siemens.
**The Aperio Programming Application is not provided by Siemens and ships with
Aperio Hub/Lock hardware.
The above list only includes the models tested with this release. SiPass integrated
can support other models available in the market but full compatibility cannot be
assured till those are also tested specifically.

4.9.2.3 I/O
AFI5100 IPM AFO5100 AFO5200 8IO 4253 I/O IOR6
Revision B OPM Revision A Revision 04
Revision A

4.10 API / HLI Compatibility


The sections that follow provide information on the backwards compatibility of the
current interfaces available in this release of SiPass integrated.

4.10.1 HR-API Interface


SiPass integrated HR-API allows data to be accessed and maintained from any
programming language that supports COM automation. In addition, the RESTful
HR-API Web Service is also available.
SiPass integrated RESTful HR API has now modified the event names to
appropriately describe the event types. This is a breaking change compared to
SiPass integrated 2.80 version. For more information, refer RESTful HR API
Release Notes in the RESTful API folder of the SiPass integrated software bundle.
SiPass integrated implements and recommends high server security which means
modification is required for any existing applications that have been built around
versions prior to MP 2.70. SiPass integrated MP 2.70 onward requires establishing
an authenticated connection to be set up with the HR-API application.
For more information, see the documentation in SiPass integrated API and
RESTful API folder in the SiPass integrated software bundle.

4.10.2 Management / Enterprise Station API


SiPass integrated Management Station API (MS-API) allows data to be accessed
and maintained from any programming language that supports RESTful web
services or COM automation.
To use WCF service during authentication, additional steps are required in the MS-
API (DCOM) to configure the certificate for WCF security. For more information,
see the MS API Programmer’s Reference Manual in SiPass integrated software
bundle.
The third-party applications integrated with MS API (DCOM), using reference of
Interop.COMClientAPILib.dll must perform the following steps to make their
application work uninterrupted.

16 | 38 A6V11170897
SiPass integrated Installation Compatibility 4
Video Management System

4.10.3 OPC A&E Server Interface


SiPass integrated supports OPC A&E version 1.0

4.10.4 SiPass integrated with Siveillance VMS


SiPass integrated MP2.95 can be used as a head end system for Siemens
Siveillance VMS 2023 R2 with VMS Connector v1.1.2 and Siemens Siveillance
VMS 2023 R2 can be used as a headend system with SiPass Integrated MP 2.95
using Siveillance_Video_ACM_SiPass_Integration_4.2.2 plugin.

NOTICE
Siveillance Video supports only live and recorded streams but events and alarms
cannot be received by SiPass integrated.

4.11 Video Management System


Siveillance VMS 2023 R2 Cayuga R13 Cayuga R14

4.12 Directly Connected IP Camera Compatibility

AXISP1354 AXIS M3007 AXIS P5534 AXIS P7214**


Fix Camera Fix Dom PTZ – Dom, Live View Video Encoder

While the above cameras have been specifically tested, an IP camera using the
RTSP protocol should work properly. Please test before purchasing and installing
onsite.
For live streaming with IP Cameras, SiPass integrated supports the RTSP as
command protocol and RTP for the data stream. The Codecs that are supported
are: MJPEG, MPEG4, and H264.
PTZ functions are not supported for any IP camera directly connected to SiPass
integrated.
**Only IN1 is supported.
If recording is required, the IP camera has to be connected via DVR.

4.13 Intrusion Panel Compatibility


Siveillance Intrusion Intrunet SI 400 series SPC 4300, 5300, 6300
Core (Sintony 400) Intrusion System
CORE-SPC 4000, 5000,
6000

ACC-AP and AC5200 (ACC lite) controller do not work with Sintony 400.

A6V11170897 17 | 38
4 SiPass integrated Installation Compatibility
Network Communication

4.14 Network Communication


Encryption of ACC and SiPass communication AES 128 Bit

SSL Encoding protocol for SiPass client/server communication TLS 1.2

4.15 Communication Encryption among SiPass


integrated Components
Component Encryption type
Connection Type
Card to Reader Dependent on Card and Reader technology.
Note:
● Encryption also depends on the connection type
between the card reader and ACC.
For example, “HID Prox over Wiegand” has no
encryption and can be easily copied.
● Encrypted does not always mean secure. Smart
Cards are encrypted but some card technologies may
still be vulnerable.
For example, in case of MIFARE Classic, information
about card decryption is available.
To know more about other secure encrypted cards, see
the information supplied by your reader vendor.
Reader to RIM / Unencrypted: OSDP V1 and other Reader Interfaces
Reader to ACC Encrypted: OSDP V2
RIM to ACC Unencrypted (Obfuscated for ACC FLN Bus)
ACC to HLI Interface Unencrypted
ACC to Syntony Unencrypted
Interface
ACC to SPC Interface Encrypted
ACC to SiPass Server Encrypted
ACC to ACC (Peer-to- Encrypted
Peer)
SiPass Server to SQL No encryption: Shared Memory Protocol – this is a local
DB connection between two processes
Remote Client to ● Configuration Client: a mix of DCOM / RPC / WCF*
SiPass Server ● Operation Client: WCF*
* Certificate Encryption for WCF
DVR API to SiPass Unencrypted: DCOM
Server
OPC Client to SiPass Unencrypted: DCOM
Server
MS DCOM and Unencrypted (uses MS DCOM API connection)
RESTFul API to
SiPass server

18 | 38 A6V11170897
SiPass integrated Installation Compatibility 4
Modem Compatibility

Component Encryption type


Connection Type
HR DCOM and Unencrypted: DCOM
RESTFul API to Secured http Encryption between HR RESTful API and
SiPass server SiPass Server (by using the self-signed certificates or
certificates from the trusted certificate authorities)
Web site to SiPass Secured http Encryption between browser and UI, and
server API of Web Client (by using the self-signed certificates, or
certificates from the trusted certificate authorities)

4.16 Modem Compatibility

ETM9440-1 HSPA+/UMTS/GSM/GPRS Terminal (3G GSM modem)

While some previous modems have been discontinued, Windows-based modems


compatible with your operating system will work. It is recommended that the same
modem type be installed throughout an installation to ensure compatibility. Other
modem brands may be compatible but have not been tested. It is recommended
that you test the compatibility of these modems prior to installation at any facility.
Further, additional checks should be performed to ensure that your modem is
compatible with your Operating System. For any specific modem capabilities,
contact your local support.

4.17 Card Printer Compatibility


Fargo Pro - Series Fargo High Definition
HDP8500, HDP 5000, HDP600, HDP800

Fargo Direct-to-Card Fargo Persona (C25) Zebra ZXP Series-


(DTC500 Series) 1

For Fargo HDP8500 card printer, different set of drivers configuration settings are
required depending on whether the printer is used for Local Connection (USB) or
Network Connection (Ethernet).
See the SiPass integrated Configuration Client User Guide(Version MP2.76 and
later) for setup and configuration of the printer. For troubleshooting information,
see the Troubleshooting section in SiPass integrated Installation Guide (Version
MP2.76 and later).

Note
For optimum configuration and operation, HDP5000 printer should not be used as
a network port printer.

A6V11170897 19 | 38
4 SiPass integrated Installation Compatibility
Mifare Classic/ DEsfire EV1 Card Encoding (while printing)

The above table only lists those card printers that have been tested with SiPass
integrated. All Windows compatible card printers should operate correctly with
SiPass integrated. However, it is recommended that you test your card printer for
correct operation before installation in a live environment. Further, additional
checks should be performed to ensure that your card printer is compatible with
your Operating System.
Ensure that the firmware of your Card Printer is upgraded to be compatible with
the Operating System on your computer.

4.18 Mifare Classic/ DEsfire EV1 Card Encoding


(while printing)
Fargo with GEM Plus 680 SL encoder Fargo with GEMeasyAccess332
installed by Interproc encoder, installed by Interproc
(www.intraproc.com – GCI680 Driver) (www.intraproc.com – GCI680 Driver)

HID OMNIKEY 5021 HID OMNIKEY 5121 (embedded)

Supported for Single printing and encoding, and Batch printing and encoding

4.19 Enrolment Reader Compatibility

4.19.1 USB Enrolment readers


Profile Reader – Profile Reader – Profile Reader – Profile Reader –
HID Omnikey HID Omnikey 5422 HID Omnikey HID Omnikey 5x27
5022 5x21

The above list includes only the readers that have been tested to work with SiPass
integrated MP 2.90. More readers (like the list below) are also supported, however,
full compatibility cannot be assured until those are tested specifically.

Bioscript Reader Cerpass Profile Reader - Profile Reader -


Configuration Registration GEMPLUS GEMPLUS
Reader GCI680 GEX332
SALTO Data SiPass Proximity USB Reader USB Reader
Configuration Reader Interface – Clock Interface –
& Data Wiegand

20 | 38 A6V11170897
SiPass integrated Installation Compatibility 4
Card Format Compatibility

4.20 Card Format Compatibility

4.20.1 Reader Connection Types

Wiegand RS-485 Clock & Data

(DRI Version D1) does not support the connection of RS-232 type readers.

4.20.2 Siemens Proprietary Card Formats

CerPass/SiPass RS-485 Siemens Corporate 31-bit STG 36-bit Asco Siemens 52-bit
Card

4.20.3 Proximity Formats

26-bit 36-bit 27-bit 27-bit HID Proximity SIEMENS


(industry standard) ASCO Indala Cotag Encrypted 52 Bit

HID Corporate Custom Wiegand 34-bit Europlex 37-bit REMEC


1000/2000

4.20.4 Smart Card Formats

32-bit CSN 40-bit CSN 26-bit Standard* HID*


(CSN32) CSN40) stored in sector) iCLASS UID

*SiPass integrated supports CSN, UID, and Data on-card for iCLASS HADP
readers. Please note that the format for Data on-card should be a maximum of 8
bytes of binary data (no special format, just a 64-bit card number).

4.21 Card Reader Compatibility

4.21.1 Readers Supporting the DESFire EV1 Card Technology


Siemens RS485 UID Siemens Reader Siemens Reader Clk/Data
Clk/Data UID Extended

A6V11170897 21 | 38
4 SiPass integrated Installation Compatibility
Card Reader Compatibility

AR40S-MF AR10S-MF AR41S-MF AR11S-MF

VR10S-MF VR40S-MF VR20M-MF # VR50M-MF #

#See the Firmware Known Issues in the Enhancements and Quality


Improvements document in the SiPass integrated software bundle.

The above readers are all mapped to the Siemens Reader Card Technology, and
become available with the Siemens RS485 Clk / Data reader license. They can
be configured on the FLN Configuration dialog of SiPass integrated.
The AR readers should be configured with Siemens OSDP NGCR (76).
Not all of the compatible readers listed above support the reader offline indication.
Different reader manufacturers follow their own practices to include such features.

4.21.2 HID Proximity, iCLASS (SE), iCLASS Seos and Mifare


Classic/DESFire
ProxPro MiniProx MaxiProx ThinLine II ProxPro II ProxPoint Plus
Wiegand Wiegand (5375) Wiegand Wiegand (6005)
(Keypad) (5365) (5395) (5455)
(5355)

iCLASS LCD/Keypad iCLASS SE and iCLASS SE and iCLASS SE and


multiCLASS SE Mini multiCLASS SE multiCLASS SE Wall
Mullion Mullion Switch

RKL55 – 6170B* R10 – 900N* R15 – 910N* R40 – 920N*


RP10 – 900P* RP15 – 910P* RP40 – 920P*
Options include Options include Options include
Wiegand or OSDP Wiegand or OSDP Wiegand or OSDP
v1/v2, Mobile Ready or v1/v2, Mobile Ready or v1/v2, Mobile Ready or
Mobile Enabled. Mobile Enabled. Mobile Enabled.

iCLASS SE and iCLASS SE and iCLASS SE 13.56MHz iCLASS SE UHF Long


multiCLASS SE Wall multiCLASS SE Décor Long Range Range
Switch Keypad

R4K0 – 921N* R95 – 95A* R90 – 940N* U90 – RDRSEU90*


RPK40 – 921P* RP95 - 95AP*
Options include Options include
Wiegand or OSDP Wiegand or OSDP
v1/v2, Mobile Ready or v1/v2.
Mobile Enabled.

iCLASS, iCLASS SR, Seos (Part No. 928NFNTEK000TE)

RDR/ENROLLER, RKLB40, ICLASS, SE E, HF STD BIO/SEOS BIO, LCD/BIO, WIEG, TERM, BLK,
STD-1, LED RED, FLSH GRN, BZR ON, LCD 1F, KPF, BFFRD 1 KEY, NO PAR, 4-BIT MSG, IPM
OFF
● Wiegand/Clock & Data output
● iCLASS, iCLASS SR, Seos biometric templates only
● bioCLASS Rev B iCLASS legacy template support
Not Supported
● bioCLASS Rev A iCLASS legacy template
● ISO14443A UID

22 | 38 A6V11170897
SiPass integrated Installation Compatibility 4
Card Reader Compatibility

4.21.3 HID Readers for Siemens Sites


Form Low High Communic Connecti SE Part No. Description
Factor Frequen Frequency ation on Style
cy (125 (13.56 MHz) Protocol
kHz) Interpreter
Interpret
er
R10 N Y Wiegand Pig tail 900NWNNEKE LF OFF, HF
Series 00K9 STD/SIO/SEOS/M
IGR, WIEG, PIG,
BLACK, HF MIGR
PFL
EVC00000_ICE05
27

R10 N Y OSDP/RS- Pig tail 900NWPNEKE LF OFF, HF


Series 485 00PJ STD/SIO/SEOS/M
IGR, 485HDX,
PIG, BLACK, A/V
OFF, OSDP V1,
HF MIGR PFL
EVC00000_ICE05
27

R15 N Y OSDP/RS- Pig tail 910NWPNEKE LF OFF, HF


Series 485 00PJ STD/SIO/SEOS/M
IGR, 485HDX,
PIG, BLACK, A/V
OFF, OSDP V1,
HF MIGR PFL
EVC00000_ICE05
27

R 40 N Y Wiegand Pig tail 920NWNNEKE LF OFF, HF


Series 00K9 SEOS/MIGR,
WIEG, PIG,
BLACK, HF MIGR
PFL
EVC00000_ICE05
27

R 40 N Y OSDP/RS- Pig tail 920NWPNEKE LF OFF, HF


Series 485 00PJ STD/SIO/SEOS/M
IGR, 485HDX,
PIG, BLACK, A/V
OFF, OSDP V1,
HF MIGR PFL
EVC00000_ICE05
27

R95A N Y OSDP/RS- Term 95ANWPTEKE LF OFF, HF


Series 485 00PJ STD/SIO/SEOS/M
IGR, 485HDX,
TERM, BLACK,
A/V OFF, OSDP
V1, HF MIGR PFL
EVC00000_ICE05
27

R95A N Y OSDP/RS- Term 95ANWPTEW LF OFF, HF


Series 485 E00PJ STD/SIO/SEOS/M
IGR, 485HDX,
TERM, WHITE,
A/V OFF, OSDP
V1, HF MIGR PFL
EVC00000_ICE05
27

A6V11170897 23 | 38
4 SiPass integrated Installation Compatibility
Card Technology Compatibility

Form Low High Communic Connecti SE Part No. Description


Factor Frequen Frequency ation on Style
cy (125 (13.56 MHz) Protocol
kHz) Interpreter
Interpret
er
R95A N Y OSDP/RS- Term 95ANWPTEGE LF OFF, HF
Series 485 00PJ STD/SIO/SEOS/M
IGR, 485HDX,
TERM, GREY,
A/V OFF, OSDP
V1, HF MIGR PFL
EVC00000_ICE05
27

Note: For more information, check product documentation on www.hidglobal.com

4.22 Card Technology Compatibility


ARxxS- ARxxS-MF ARxxS-MF ARxxS-MF ARxxS-MF ARxxS-MF
MF OSDP All HID OSDP OSDP BCD OSDP BCD OSDP
OSDP1 Prox2 ASCII Packed Unpacked Custom3
ARxxS-MF ARxxS-MF ARxxS-MF ARxxS-MF ARxxS-MF
OSDP Mifare OSDP Mifare OSDP Mifare OSDP Raw OSDP Sector
Facility4 GID5 Numeric 7 26-bit6

1Alldata from the reader is the card number. The license is as Siemens reader.
2This is equivalent to AllHidProx – Wiegand data encoded onto a smart card. The
license is as the appropriate Prox. Card technology (This is useful for iCLASS
MultiProx readers).
3Custom Wiegand profile. License is as Custom Wiegand.

4This is a Mifare Facility card, encoded by SiPass. The license is as Mifare

Facility.
5This is a Siemens GID format. The license is as Siemens GID.

6This is a 26-bit wiegand card, as encoded by SiPass onto a smart card. The

license is as Mifare 26-bit.

4.22.1 Formats supported by All HID Prox Technology


Custom Wiegand HID Prox 26 Bit HID Prox Asco 36 Bit
HID Prox Corp 1000 35/48 HID Prox Siemens Encr HID Prox Siemens
bit 52-bit Stg
Mifare Csn32 Mifare Csn40 Europlex 34Bit Remec 37Bit

24 | 38 A6V11170897
SiPass integrated Installation Compatibility 4
TBS 3D Enroll

4.23 TBS 3D Enroll


The following TBS 3D Enrollment USB based device have been tested and verified
as working with SiPass integrated Web Client.

Design Product Number Model Description


TBS 053-1000-002 3D Enroll ● Access Control, T&A, Civil ID
● Highest security level
● No “Failure to Enroll”
● Superior image quality
● Nail-to-nail images
● Quality assessment and duplicate check
● Hygienic for sensitive applications
● Touchless,3D-Multiview
● Certifications: CE

TBS 073-1000-002-1-00 2D Enroll ● Optical touch sensor, FBI certified


● Access Control, T&A, Civil ID
● Excellent identification performance
● Small- and medium-sized user groups
● Quality assessment and duplicate check

The fingerprint template layout is defined using the enrollment reader setup but
the enrolment can be performed using SiPass.
The reader configuration requires installation of drivers.
It is not possible to use fingerprint-only as a credential in SiPass integrated.
TBS server holds the fingerprint in its own database that can be retrieved by
SiPass integrated web client by the authorized user only.

4.24 Granta MK3 Reader PIN Pad Type Compatibility


SiPass integrated supports the Pin Pad types 1, 2 and 3. The type can be
configured on the FLN Configuration dialog.
See Chapter 6 of the 4101-3 Controller Installation Handbook for information on
Installation and Configuration.

For the 4422 Swipe module and the 4322 Cotag module, the keypad type has to
be selected on an extra Key tab during configuration.
The system does not support entry of your own PIN for first-time use.
An External Swipe reader, combined with a keypad, can be configured as an M43
Keypad Type.

A6V11170897 25 | 38
4 SiPass integrated Installation Compatibility
Signature Capture Tablet Compatibility

4.25 Signature Capture Tablet Compatibility

Topaz HSB (USB) signature capture T-LBK460-HSB-R


pads

4.26 Messaging System Compatibility

Microsoft Exchange Server 2013 or newer

Email forwarding may not be supported or may not support the sending of emails
externally, under certain corporate email conditions or specific corporate
implementations.

4.27 Server Redundancy

Stratus Technologies EverRunFT

The above software is recommended based on tests done with SiPass integrated.
Contact Stratus Technologies directly for any support with the software.
The redundancy is based completely on the hardware, and is not based on the
SiPass services.

4.28 Offline Door System

SALTO SPACE Version 6.8.3.1

26 | 38 A6V11170897
SiPass integrated Installation Compatibility 4
Identity Management

The SHIP protocol (version 1.35a) should be enabled for this feature.
Refer to the SALTO documentation for the maximum length of text or other
potential limitation.
SiPass supports up to 40 characters for naming entities (like Cardholder First
Name and Last Name, Access Level, Access Groups and Time Schedules) and
this can be lesser in SALTO. If the entity name in SiPass integrated is longer than
the naming character limit in SALTO, the name will be truncated before being
sent to SALTO. After truncation, if the name is duplicated in SALTO, it results in
an error (logged in SiPass server log file) and the information is not sent.
The maximum number of time schedules is 65000 in SiPass integrated and 256 in
SALTO. These time schedules are the ones having a value of 1-256 in the Time
Schedule No. field on the Time Schedule dialog. Hence, any time schedule
having a number less than 256 can be used for the SALTO system.
The maximum number of holiday types is 8 in SiPass integrated and 3 in SALTO.
Hence, only the holiday types 1-3 in SiPass system can be used for SALTO.
The maximum number of offline doors that can be assigned to one cardholder is
96 in SALTO. To configure more, the doors must first be added to a zone in the
SALTO system (up to 1000 doors per zone and 1000 zones per system).and then
the zone can be assigned to the cardholder in SiPass integrated (multiple zones
can be assigned to a cardholder).

4.29 Identity Management


Siveillance Identity 1.6 SP2

4.30 Virtualization

Citrix XenApp Microsoft Windows Server Microsoft Windows Server


Version 6.0 2022 Terminal Services 2019 Terminal Services

It is highly recommended that your system is based on suitable hardware and


system specifications.

A6V11170897 27 | 38
5 SiPass integrated Server, Configuration Client and Operation Client
Fixed Issues

5 SiPass integrated Server, Configuration


Client and Operation Client

5.1 Fixed Issues

Vulnerabilities
Type Description
Server Client While logging on to the Operation Client and Configuration
Client, an error message box pops up if the file log4j-1.2.12.jar
(which has reached End of Life) is removed from the SiPass
installation folder.
If you are not using VSS SDK, you can delete either the log4j-
1.2.12.jar located in “<InstallationPath>\SiPass
integrated\VssSDK\jars” or the entire folder
“<InstallationPath>\SiPass integrated\VssSDK”.
The video integration functionality is impacted if the file/folder is
removed.
Note: This applies to remote clients as well.

Fixed Issues
Type Description
Server Client When Cardholder is updated through HR API, the smartcard
profile name is not sent to server. Hence, SmartCardID event
gets created after performing update.
Server Client When Cardholder is updated through HR API, value of restricted
visitor field is false by default. Hence, restricted event gets
created after performing update.
Server Client In German Localization package of MP2.90 (DE), Reading the
encoded card using proximity enrolment reader displays an
error.
Server Client Currently, SiPass integrated software and hardware supports
less than 256KB size of reader firmware download.
Server Client Currently, in SiPass integrated for localized languages, if demo
license is applied, then Siemens Corporate Card tab is visible.
Server Client Database restore is not successful when SiPass integrated web
client is installed separately after installing SiPass integrated
server. Also, if user stops and starts the SiPass Server
manually, all the services related to SiPass integrated web client
are not started automatically.
Server Client The following issues have been reported:
● The maximum password age set for the operator does not
expire in the Operation Client and does not prompt to
change the password after expiry.
● The password changed after expiry does not reflect in the
Configuration Client.
Server Client In Operation Client, error is displayed when user tries to add
reporting actions to pre-defined Reports after database restore.

28 | 38 A6V11170897
SiPass integrated Server, Configuration Client and Operation Client 5
Fixed Issues

Fixed Issues
Type Description
Server Client During Database restore, the restore progress bar percentage is
not completed and getting struck in Configuration Client GUI.
Server Client Backup file generated via HBET does not have all necessary
data related to custom pages. Due to this Cardholder/Visitor
form does not load after database restore.
Server Client System Events are reported to SiPass integrated Live Audit Trail
window but are not stored in the database.
This issue can be observed in below scenarios:
● RabbitMQ Queue creation failure on first SiPass Server
startup after installation. System events are lost.
● RabbitMQ Queue connection failure on SiPass Server
startup. System Events are buffered inside the queue until a
successful connection is established (restart of SiPass
Server PC is required) and then system events are pushed
to the database.
In the SiPass system, architectural changes have been made to
acknowledge events synchronously in the RabbitMQ to address
the data loss.
Server Client In some cases, if you send a command to disable the "REX"
input point after it has already been disabled because of a
"Block door" command sent prior, the status of the input point
changes to "Unknown".
Server Client The license expiration is displayed wrong in the Status Bar
dialog of the SiPass integrated Configuration Client and SiPass
integrated Operation Client. The license expiry date displays the
current date.
Server Client In SiPass Configuration Client, the custom color option is not
working in the “Card Template” configuration and not available
on the toolbar.
Server Client SiPass integrated is now enhanced to support private key as
input file, when a certificate does not have a private key
associated with it or does not have exportable private key
enabled by default.
Server Client "Pager Number" format validation is removed. You may enter up
to 16 characters, in any combination of upper-case and lower-
case letters and numbers.
Server Client Audit Trial Archive was not generated for the current day when
triggered manually from SiPass integrated Configuration Client.
After applying the patch, manual trigger of audit trial archive will
archive the available audit trials till current day in the configured
path.
Server Client Previous Hotfix installer does not validate the rights to execute
PowerShell script/command script/batch file and Hotfix
installation is incomplete.
Hotfix installer validates the rights to execute PowerShell
script/command script/ batch file and if rights are not present
error message displays "Installation is aborted. Batch
file/Command Prompt/PowerShell execution is
restricted/disabled. Please check the logs for further
information." and installation does not proceed.

A6V11170897 29 | 38
5 SiPass integrated Server, Configuration Client and Operation Client
Fixed Issues

Fixed Issues
Type Description
Server Client SiPass integrated Configuration Client fails to take backup when
the database size is larger than 4 GB.
Server Client User is unable to perform backup of the database in SiPass
integrated due to excess custom fields and entity records
created during Update Cardholder through SiPass integrated
HR RESTful API.
Server Client After initializing the controller, Cardholder is getting access to
few unconfigured floors.
During initializing the controller, while downloading access level,
only points corresponding to the controller are downloaded.
Server Client When creating/updating a cardholder with the Data-
Synchronizer/Import-Export tool, the “Key Revalidation” value is
not synchronized between SiPass integrated and SALTO
system.
Server Client If more than 4000 characters are entered in the User Name field
in the SiPass integrated Configuration Client login page, then
SiPass integrated Configuration Client, SiPass Management
Station API service and SiPass Server service crashes.
Server Client Whenever RabbitMQ service crashes, SiPass server service is
stopped immediately, and event acknowledgement is not sent to
the controller to prevent data loss.
Server Client Host Based Event Tasks (HBET) configured/last modified by an
operator is not triggering event if the operator has been deleted
and SiPass integrated Server is restarted.
Server Client Messages are stuck in RabbitMQ queue and events are not
reported to SiPass integrated Live Audit Trail window and
External Event Queue.
Server Client The following issues are reported in the SiPass integrated
system:
● Alarms are reported in SiPass integrated system even
though there is a schedule on the point to ignore alarms.
● Alarms are reported in SiPass integrated system in Intrusion
Zones which are disarmed.
● Points which are always monitored are reporting in the Audit
Trail but are not always showing a pop-up message and/or
reporting into the Alarm Queue.
Server Client After initialization of the controller, access is denied to the
cardholder for the point which has been assigned after 65535
points.
Server Client Cardholder allowed access where no access was given. Access
Granted for unassigned readers & Access Denied for assigned
readers.
Server Client When OSS-SO Access group (containing Access Level which
has point group configured to it) is assigned to cardholder /
removed from cardholder, update was not to the controller on
cardholder Save operation.

30 | 38 A6V11170897
SiPass integrated Server, Configuration Client and Operation Client 5
Known Issues and Limitations

Fixed Issues
Type Description
Server Client In SiPass integrated Operation Client, during report generation if
the search result has more than one page, second page result is
not loaded.
Server Client When operator with limited admin rights tries to open
Cardholder details in the Operation Client, it throws an error
message and crashes.

5.2 Known Issues and Limitations


● The Siveillance VMS Connector v1.1.1 to SiPass connection does not work if
VMS is using a certificate. Hence, it is recommended that DVR API connection
should NOT use any certificates.
● After restoring the SiPass integrated database, the Cardholder cannot be
searched by the ManagerEmailAddress field value. To resolve, open the
report to refresh the data after which, the search can be performed with this
value.
● After a point name change, Alarm Acknowledgments in the Audit Trail still show
the old name. A service restart is required for normal operation.
● Changes made to alarm instructions made from the SiPass server when the
client is NOT connected are not updated in the Client even after it is connected
(logged-in) the next time. Hence, it is recommended to edit the alarms when
the Server and client are online (connected).
● Some SiPass integrated files occasionally show false-positive results with
some anti-virus scanner products. At the time of writing, the
SiPassConfigurationClient.exe file is flagged as ‘Unsafe’ by the “Cylance” anti-
virus product. However, several other known anti-virus vendors have cleared
this file during their scans.
● In the SiPass integrated Data Synchronizer Tool & Import Export Tool,
Cardholder must be imported with any one of the defined workgroups else the
workgroup will be updated as <None>.
● SiPass integrated does not accept the special character “-“ (hypen) if it is
included in the NetBIOS name. For example, siemens-lan.

5.2.1 SiPass integrated Firmware


● In case of upgrade from SiPass integrated MP2.76 to MP2.76 SP1 or later:
If the UID card technology was used for APERIO Locks with ACC Version
2.76.14 and UID Reverse Byte Order configuration option was enabled, the
UID Reverse Byte Order configuration option MUST BE DISABLED when
upgrading to a later version of the ACC firmware.
● ACC-AP does not support a few types of Wiegand readers:
– AR6111 MX is known to be NOT working
– Recommended: HID Wiegand readers
● VR20M-MF and VR50M-MF reader firmware older than version 2.002.000
cannot be downloaded via SiPass integrated. The issue may get resolved by
the reader manufacturer in Firmware version 2.002.000 onward.
● VR20M-MF and VR50M-MF reader firmware older then version 2.002.000 had
incompatibility issues with SiPass integrated. The issue has been resolved by
the reader manufacturer in Firmware version 2.002.000 onward.
● PHG reader firmware download only works at 9600 baud.
● PHG readers can have their address set either by DIP switch or by OSDP
command. If it set by the DIP switch, the address cannot be changed from the
ACC (despite a message that it was changed).

A6V11170897 31 | 38
5 SiPass integrated Server, Configuration Client and Operation Client
Known Issues and Limitations

5.2.2 Configuration Client - Card Template


User cannot choose a custom color while creating Card Template, Site Plan and
Drawing in SiPass integrated Configuration Client.

32 | 38 A6V11170897
SiPass integrated Web Client 6
Fixed Issues

6 SiPass integrated Web Client

6.1 Fixed Issues


Fixed Issues
Type Description
Web Client The Authentication endpoint of SiPass integrated Web UI API can
only be invoked by the SiPass integrated external operator.
After applying this patch, the restriction was removed so that the
default operators containing cardholder privileges can invoke.
Web Client In SiPass integrated Web Client, it is not possible to delete
Cardholders. An internal server error is displayed.

6.2 Known Issues and Limitations

6.2.1 Known General Issues


Common for All Applications
1. In the dialog box, on selecting the access objects checkbox, the list refreshes.
2. In the Combo box, the default value Please select a value does not display
randomly.
3. The Close button is not translated in the configuration screen.

6.2.2 Known Issues for Live Alarm


1. The field Time cannot be searched through the quick search or extended
search option.
2. In Extended Search, when user searches Alarm Date Time/Date/Time fields
with incorrect format, a validation message Date/Time format is incorrect and
should be in <Date Time format> displays twice. In addition, the user will still
be allowed to search the Alarm Date Time/Date/Time, even when the validation
message box is still visible in the screen.
3. While acknowledging the Alarms, the following error String was not
recognized as a valid Date Time displays.

6.2.3 Known Issues for Cardholder/Visitor Application


1. In the Detailed View,
– the chevron button near the tabs does not work all the times.
2. While scrolling down the Cardholder list, randomly, the records display for half
a page.
3. When the application is logged in through other languages except English, the
field Status cannot be searched through the quick search or extended search
options.
4. In Extended Search, when user searches Start Date/End Date fields with
incorrect format, a validation message Date format is incorrect and should
be in <Date Time format> displays twice. In addition, the user will still be
allowed to search the Start Date/End Date, even when the validation message
box is still visible in the screen.

A6V11170897 33 | 38
6 SiPass integrated Web Client
Known Issues and Limitations

6.2.4 Known Issues for Page Customization


1. Even if the fields WorkGroup and Profile are set as mandatory in the Custom
page design and Advanced tab, system allows to save the Cardholder /
Visitor application without prompting a validation message.
2. During database restore, the remaining fields Reason for Visit, Profile, and
License of the Visitor Details tab gets displayed in the Extended Controls
tab.
3. Date Time format selected in custom page of operational client does not
display in the same format in web client.

6.2.5 Known Issues for Venue Booking


1. When user tries to edit a recurrence booking record e.g. Record A, by clicking
the Show Calendar button, but edits an occurrence booking record e.g.
Record B, a message displays as TypeError: Cannot read property
'toString' of undefined randomly.
2. User creates a booking, by selecting the End of Recurrence option as End by
(MM/DD/YYYY) from the Recurrence Range section. After the booking is
created, if user creates another record, by default, the End after (no. of
occurrences) field should be selected. However, End by is shown as selected.
3. User creates a booking, by selecting the Repeats option as Every Weekday
from the Recurrence Pattern section. After the booking is created, if user
creates another record, by default, the Every (no. of days) field should be
selected. However, Every Weekday is shown as selected.
4. While creating a venue booking with recurrence option, at times, the list view
does not get refreshed automatically.
5. Irrespective of the languages chosen while logging in the client, if user changes
the default Time Zone, the date time search does not work for Venue Booking.
6. In Reccurrence Booking, the End by calendar control goes beyond the
selection and does not allow the user to select the date. This issue occurs in
smaller screen, for e.g. laptop view.
7. In Extended Search, when user searches From/To fields with incorrect
format, a validation message Date/Time format is incorrect and should be in
<Date Time format> displays twice. In addition, the user will still be allowed to
search the From/To fields, even when the validation message box is still visible
in the screen.
8. The following issues are by design in the SiPass integrated and arise during
concurrent usage of the application:
– If user accesses or deletes a non-existing item, an exception error displays
as “Access Denied”.
– If user edits and saves an already deleted record of a recurrence booking,
the list view does not get refreshed, and an exception error displays as
“Access Denied”.
– If user edits and saves an already deleted record of an occurrence booking,
the list view will be refreshed and displays two error messages such as
Unknown Venue Booking and Access Denied.

6.2.6 Known Issues for Localization


Common for All Languages
1. In About application, the text Version is not localized.
2. Alarm Date Time field search does not work.
3. While accessing the application in the localized languages, at times, the length
of the contents in the controls are overlapped over other controls and does not
allow the user to perform a particular operation.
4. In the Cardholder application,

34 | 38 A6V11170897
SiPass integrated Web Client 6
Known Issues and Limitations

– under the Definition tab, the Cardholder Attributes’ Status field is


displayed as Unknown and not localized.
– under the Printing tab, the Demo value of the Card Template field is not
localized.
5. The Tool tip and the Close button of the Settings icon are not localized.
6. When the application is logged in through other languages except English, the
field AlarmStatus cannot be searched through the quick search and extended
search option.

Russian
1. The Access Object grid overlaps the Cardholder Attributes.
2. In Venue Configuration, on the detailed page, the word Details Loading is
not localized.

Dutch
1. In the Access Level application,
– the word records in the No matching records found text is not localized.
– on the detailed page, the word Details Loading is not localized.
2. In the Alarm Handling page, under the Settings button, the Status option of
the Sorting field List/ Table configuration is not localized.
3. In the Visitor Management tab, under the visitor cardholder information
section, the Select cardholder and Remove cardholder are not fully displayed,
because the size of the button is small.
4. In About application, the text Version is not localized.

Italian
1. In the Manual Override application, under the tree view, the Flag and Area
Anti-Passback are not localized.

6.2.7 Limitations
1. In SiPass integrated web client, OSS-SO feature is not supported.
2. In Cardholder, Visitor, VenueBooking, and Alarm application’s Quick and
Advanced Search, the date and time field works based on the equal to logic.
3. In any application, while performing the Quick Search using date time field,
validation is performed only if the search input length matches or exceeds the
date format length. However, when the Quick Search is performed with
incorrect date/date time format, an error message is displayed as Incorrect
format in field <DateTime field>. Expected format <DateTime format>.
4. The Search option in the Cardholder and Visitor field support only and logic.
For example, when a user enters First Name and Last Name of the cardholder
in the Search field, the webclient displays the corresponding cardholder.
5. The date and time in the SiPass integrated web client works based on the
language logged in by the user. And does not depend on the regional settings
available in the system.
6. In the Configuration client, when the Priority of an Alarm is modified; the
changes made is not updated dynamically in the List view [Web client]. To
view the changes in the list view, the user must go back to the home page and
then return to the list view screen.
7. While enabling secure communication for RabbitMQ, if the private key file is
unavailable, self-sign certificate must be consumed. Refer Enabling the Secure

A6V11170897 35 | 38
6 SiPass integrated Web Client
Known Issues and Limitations

Communication for RabbitMQ section in the SiPass integrated Installation


Guide.
8. SiID version 1.5 and SiPass version MP 2.85 compatibility is no more
supported for single machine or co-existence installation.

Venue Booking
1. Only the Bookings from 30 days prior to the current date and time displays.
2. While clicking the Day, Week, or Month buttons, user can view the booking
created for a particular Day, Week, or Month. However, while clicking the
Show Calendar icon, to navigate to some other dates, user cannot navigate to
the selected date.
3. When user tries to edit a record e.g. Record A, by clicking the Show Calendar
button, but edits some other record e.g. Record B, the Start Date and Time
and End Date and Time does not change for the currently chosen Record B.
The record will be modified only when user edits the same chosen record.
4. While creating/editing a venue booking with recurrence option, the first item of
the list view will be selected, whereas in single booking (occurrence) option, the
saved record will be selected.
5. Pinning feature has some limitations in Venue Booking and Venue
Configuration. For Example: Pin an item to the home screen. From the home
screen, when user clicks the pinned item, the pinned item will not be selected
in the list view (if the selected item is not from the first page), however, the
pinned item will be displayed in the detailed view. Because of this behaviour,
the Edit and Delete buttons are disabled. In this case, the user needs to scroll
up/down to see the selected/highlighted item in the list view. After the item is
selected automatically, the edit and delete buttons will be enabled.

Extended Controls
1. When the data type of custom field textbox control is configured as Numeric in
the SiPass Configuration client and if user tries to enter alphabets in the text
box field, an error message as Internal server error displays. This error
message is also applicable for Cardholder and Visitor applications.

Cardholder
1. In the List View, the card number displays only when it is configured for the
Base profile.
2. If the card number is selected in the sorting field, the sorting order is applied for
the card numbers with Base Credential Profile.
3. Manual commands are not working as expected. [RC1]

Manual Override
1. Manual commands such as Cancel Isolate, Cancel Permanent Action,Clear
Alarm,Isolate,Pulse,Return to Time Schedule Control,Secure (Enable),Set
state Alarm,Set state Normal and Unsecure (Disable) are not supported by
MFI Tamper Input.

WARNING
Manual Commands support on the MFI Tamper Input are not suppressed
explicitly, hence executing manual command is possible and it shall cause
unnecessary modifications to the existing input state.

36 | 38 A6V11170897
DesigoCC Integration 7

7 DesigoCC Integration
Integration between SiPass integrated and DesigoCC has now become more
secure and convenient. Users can now be seamlessly be authenticated across the
integration from DesigoCC in SiPass integrated using enhancements that have
been made to the applicable APIs. Users in DesigoCC can be traced and audited
inside the SiPass integrated system, which is then compliant with the necessary
privacy and security guidelines required for the European and wider global
markets.
In addition to the user authentication enhancements, it is also possible to integrate
the two systems easily with the additional functionality available with Siemens
LMS. This means that once DesigoCC has been extended to include external
points, SiPass integrated will see this in the associated LMS server and enable the
integration services. This automation offers convenience, cost savings and
reliability for those customers who wish to have an integrated BMS and security
system.

A6V11170897 37 | 38
Issued by
Siemens Switzerland Ltd
Smart Infrastructure
Global Headquarters
Theilerstrasse 1a
CH-6300 Zug
+41 58 724 2424
www.siemens.com/buildingtechnologies

© Siemens 2023
Technical specifications and availability subject to change without notice.

A6V11170897

You might also like