Barton 316c 318c DP Indicator Switch

Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

MEASUREMENT SYSTEMS

B A RT O N ®

DP Indicators, Switches
& Transmitters

227C Indicator ITS 228C Switch 752 Transmitter 753 Transmitter

Barton DP indicators, DP switches, precision-jeweled rotary movement


IT / ITS / IS Series DP indicating that multiplies rotation of the Features (select models)
transmitters/switches, and torque tube through a gear and • SWP to 6,000 psi (414 bar)
explosion-proof electronic pinion to the pointer. The
• Weather-proof, NEMA 4 / IP65,
transmitters are available in a movement employs a thermally or explosion-proof cases
variety of safe working pressures stable Ni-Span-C hair spring.
• Stainless steel (SST) versions available
and DP ranges for measurement Zero/Range adjustments can be
• Seal-welded 224C DPU available for
of differential pressure, flowrate, made without removing the
leak-proof metering
and liquid level applications. scaleplate or pointer. Linearity
• Wide selection of DP ranges
Actuating Unit (DPU)
adjustments are readily accessible
• Variety of bellows fill fluids
after removal of the scaleplate.
Barton indicators and switches • 3", 3-1/2", 4-1/2" and 6"
are actuated by a rupture-proof Cases (76, 89,114, & 152 mm) indicator dial sizes
bellows DPU with integral The standard case for indicators • Narrow deadband switches
temperature compensation. and switches is die-cast aluminum • 1 to 4 adjustable switches (SPDT)
with a special epoxy black finish. (DPDT optional on selected models)
The 224C DPU is a dual, liquid-
Models 316C and 450C have
filled, bellows designed to • 1 or 2 DPDT Relays (selected models)
weatherproof cases, while models
withstand repeated overranges • ITS with 2 or 4 SPDT contacts
226C, 227C, and IT / ITS feature
equal to the safe working pressure (can be set for DPDT operation)
a NEMA-4 / IP65 rated case.
of the housings without any • 4-20 mA output on IT / ITS & 752 / 753 models
The Model 232C has a 304
change in calibration. The 224C • IT/ITS internal battery
stainless steel case. The Models
SWP ranges from 500 psi (34 bar) • 752 / 753 Insensitive to normal shock & vibration
290D, 322C, 752, 753, and select
to 6,000 psi (414 bar), with • 752 / 753 all DC circuitry - no RFI generation
models of the IT / ITS Series have
DP Ranges from 0-30" w.c. to
explosion-proof cases. • External sealed sensors available
0-1,000 psi. NACE-compliant
materials are available Optional non-indicating "blind" Applications
upon request. switch cases and 316 stainless • Remote level indication
Indicating Mechanism
steel cases (for offshore/corrosive • Differential pressure
environments) are available for • Absolute pressure measurement
The indicating pointer traverses
select models. Consult factory • Pressure drop across a filter
a 270° arc, providing excellent
for case option availability • High and low flow rate
readability. It is driven by a
and application.
DPU Details Range Springs - determine the DP range of the unit, based

Model 224C (Dual Bellows) upon their number and strength. They have extremely low
hysteresis and exceptional temperature stability. The M224
The 224C DPU is a lightweight compact sensor that
range springs are part of the BUA — they are not individually
incorporates a rupture-proof bellows in a common-head
replaceable parts.
design housing. It has an exceptionally fast response time, is
self-draining, and has built-in temperature compensation. Model 224C with NACE-complaint materials are available
upon special request.
The 224C DPU consists of a Bellows Unit Assembly (BUA) and
removable pressure housings. Within the BUA, flexible bellows
are secured to a centerplate. In dual-bellows models, the Special Configurations
movable bellows are rigidly connected by a dual valve stem Model 224C Absolute Pressure
that passes through the centerplate. Valve seats, in the A special version of the M224C provides direct measurement
centerplate passage, form a seal with the valves. Contacting of absolute pressure — eliminating the effects of varying
the valve stem in the centerplate is a drive arm pivoted on the atmospheric pressure. The LP bellows assembly is enclosed
end of a sealed torque tube. The bellows is filled with a clean, within a capsule. This capsule is evacuated to a very low level
noncorrosive, low-freezing point liquid. A range spring of absolute pressure and then hermetically sealed. Process
assembly provides tension against applied pressures. pressure applied to the HP housing is compared with the
established atmospheric pressure in the LP side, which provides
In operation, pressure is applied to both sides of the bellows.
a reference as close to “absolute zero” as possible. The
Any difference in pressure causes the bellows to move until
capsule is further contained within a housing that does not
the spring effect (range springs) balances out the force. The
have pressure ports. The HP housing has both top and bottom
linear motion of the bellows (proportional to the DP) is
ports for process connection, or for automatic draining of
transmitted as a rotary motion through the torque tube.
fluids or venting of gases.
In dual-bellows units, if the bellows are subjected to a DP
Model 224C Seal-Welded
greater than the unit’s DP rating, a valve closes and “traps”
the fill liquid in the bellows — fully supporting the bellows For applications requiring ZERO LEAKAGE, a special seal-
and preventing rupture. Since opposing valves are used, full welded M224C is available — a heliarc-welded joint replaces
protection is provided in either direction. the elastomer O-ring. This leak-proof metering is ideal for
applications involving hazardous fluids (e.g., N2O2, radioactive
water, toxic chemicals, etc.), as well as hard to seal gases like
Components
helium and hydrogen.
Bellows Construction - Individual diaphragms, stamped and
formed from selected materials, are assembled using highly
Features
specialized techniques, the results — exacting linearity
• All-welded chambers for process fluids
characteristics, a long cycle life, and freedom from effects of
work hardening commonly encountered with the hydraulically • Leak-tested at factory with Helium Mass-spectrometer
formed or mechanically rolled types. • DP Ranges from 0-30" w.c. to 0-400 psi
(0-75 mbar to 0-27.6 bar)
Torque Tube - eliminates possibility of leakage and need for
• SWP from 500 psi to 6,000 psi (34 bar to 414 bar)
lubrication. The needle bearing (inboard end) and ball bearing
• 316 SST Housing/Centerplate Material
(on follower drive arm) operate with a minimum of friction —
• 316 SST or Inconel Bellows Material
resulting in high sensitivity over the life of the unit.
For general specifications (not listed above), see Table 1
The torque tube assembly consists of a tube, shaft, and
on page 3.
supporting members. The outboard end of the torque tube is
attached to the centerplate. The shaft passes through the External Sensors
center of the tube and is welded to the inboard end. Refer to the Sealed Sensors Bulletin for details on applications
Since its outer end is attached to the centerplate, the tube requiring external sealed sensors, such as corrosive, high
must twist when subjected to torque. The shaft, freely temperature and hazardous fluids.
supported at its outer end and attached to the tube and drive
arm at its inner end, rotates through the same angle as the
drive arm — the mechanical output of the DPU.

2
MEASUREMENT SYSTEMS

M224C DPU Specifications


(Refer to Table 1 below)
Housings (Material/SWP) Forged Brass 500 psi (34 bar)
Carbon Steel 1,500, 3000, & 6,000 psi (103, 207, & 404 bar)
316 SST 500, 1,500, 3,000, & 6,000 psi (34, 103, 207, & 414 bar)
Monel 3,000 psi (207 bar)
Bellows Material Be-Cu, 316 SST, or Inconel
DP Ranges 500 psi (34 bar) SWP 0-30" w.c. to 0-500 psi (0-75 mbar to 0-34 bar)
1,000 psi (69 bar) SWP 0-60" w.c. to 0-400 psi (0-149 mbar to 0-27.6 bar)
1,500 psi (103 bar) SWP 0-60" w.c. to 0-400 psi (0-149 mbar to 0-27.6 bar)
3,000 psi (207 bar) SWP 0-60" w.c. to 0-400 psi (0-149 mbar to 0-27.6 bar)
6,000 psi (414 bar) SWP 0-60" w.c. to 0-400 psi (0-149 mbar to 0-27.6 bar)
Bellows Fill Fluids Mineral Oil (Standard M-Fill)
Ethylene Glycol/Water
Distilled Water
Silicone
Fluorolube for O2 Service
Others available (Contact PRIME)
Weight (approximate) Forged Brass 500 psi SWP 3.5 lbs (1.6 kg)
Carbon Steel, Stainless Steel, and Monel 500, 1000, & 1500 psi SWP 4.5 lbs (2 kg)
3000 & 6000 psi SWP 6.5 lbs (2.9 kg)
Temperature Limits -40°F/°C to +180°F (+82°C)
Ordering When ordering, specify: Quantity
Model Number
Housing Pressure Rating (SWP)
Housing & Bellows Materials
Bellows Fill Fluid
Differential Pressure Range
Mounting

Table 1 - 224/224C DPU General Specifications Table (2/06a)

BODY AVAILABLE DIFFERENTIAL PRESSSURE RANGES PRESSURE CONNECTIONS

Stainless Steel or
Beryllium Copper Bellows (224C Only) Inconel Bellows
SWP psi (bar) Housing Material Inconel Bellows Top Bottom
1-5/8" (41mm) O.D. 1-5/8" (41mm) O.D. 3/4" (19mm) O.D. 3/4" (19mm) O.D. 5/8" (16mm) O.D.

500 Forged Brass 0-30" w.c. (0-75 mbar) to 0-61 psi (0-4.2 bar) to
1/4" NPT 1/4" NPT
(34) (ASTM-B124#2) 0-60 psi (0-4.1 bar) 0-400 psi (0-27.6 bar)

500 Cold Rolled Steel (C1018) 0-30" w.c. (0-75 mbar) to 0-61 psi (0-4.2 bar) to
1/4" NPT 1/4" NPT
(34) Stainless Steel (316) 0-60 psi (0-4.1 bar) 0-400 psi (0-27.6 bar)

1,000 Copper Nickel (70-30)


MS-16142-4 MS-16142-4
224 (Non-C)

(69) (MIL-C-15726)
224C

1,500 Cold Rolled Steel (C1018) 0-400 psi (0-27.6 bar)


1/4" NPT 1/4" NPT
(103) Stainless Steel (316) 0-60" w.c. (0-149 mbar) 0-61 psi (0-4.2 bar)
Cold Rolled Steel (C1018) 0-60" w.c. (0-149 mbar) to to 0-61 psi (0-4.2 bar)
3,000 0-60 psi (0-4.1 bar) 0-400 psi (0-27.6 bar)
Stainless Steel (316) to to 1/2" NPT 1/4" NPT
(207)
Monel 0-60 psi (0-4.1 bar) 0-400 psi (0-27.6 bar)

6,000 Cold Rolled Steel (C1018)


1/2" NPT 1/4" NPT
(414) Stainless Steel (316)

Net Volume L.P. Head 1.66" (27.2 cc) 1.66" (27.2 cc) 2.51" (41.1 cc) 2.51" (41.1 cc) 2.61" (42.8 cc)
cu.in. (cu. cm) H.P. Head 1.55" (25.4 cc) 1.55" (25.4 cc) 2.42" (39.7 cc) 2.42" (39.7 cc) 2.50" (40.9 cc)

Displacement cu.in. (cu. cm) for full-scale Travel 0.14" (2.3 cc) 0.14" (2.3 cc) 0.03" (0.49 cc) 0.03" (0.49 cc) 0.025" (0.41 cc)

Performance: Torque Tube Rotation = 8° ±10%; Torque Tube Material = Beryllium Copper (BeCu); Temperature Limits = -40°F/°C to +180°F (+82°C); Maximum Non-linearity = per Range;
Repeatability = 0.2% of full scale differential pressure (see DP Indicators, Switches, & Transmitters bulletin #21920 for additional information).

Notes: Zero center or split ranges available on special order (e.g., 0-60" w.c. (0-149 mbar) range may be ordered 30-0-30" w.c. (75-0-75 mbar) or (15-0-45" w.c. (37-0-112 mbar). Absolute pressure ranges available
from 30" w.c. (75 mbar) to 600 psi (41.4 mbar). Other sizes and types of connections (welding stubs, MA, A.N.D., etc.) available upon request. Outline dimension drawings available upon request. Metric conversions ( )
are approximate. M224C with NACE (MR-01-75) compliant materials available upon request. Model 224 (Non-C) for specific Nuclear/Government applications only.

3
DP Indicators

Model 226C Model 227C Model 232C Model 247C Model 450C

Model 226C (w/224C DPU) Model 246/247C (w/224C DPU)


A 3-inch (76 mm) indicator is a lightweight and compact A portable 6-inch DP indicator with a built-in 3-valve manifold
instrument for use where panel space is at a premium. and bleed valves. This ready-to-use assembly is mounted in a
Model 227C (w/224C DPU)
tough leather-like plastic carrying case (w/indicator and
manifold mounted to the base). The included neoprene hoses
A 6-inch (152 mm) indicator that is ideally suited for tank level,
can be stored in the case.
flow, and pressure drop across filters. This model is also
available in stainless steel (M227CS). Model 450C (w/224C DPU)

Model 232C (w/224C DPU)


A rugged 4-1/2 inch (114 mm) indicator that offers economy
of space and readability. Available with top/bottom or
An economical 6-inch (152 mm) DP indicator that is designed
rears ports.
for use in applications where high accuracies are not required.
Suitable for tank level, flowrate, and DP across filters
applications. It features a 500 psi (34.5 bar) SWP Maximum
and a 0-50" w.c. to 0-100 PSID (0-124 mbar to 6.9 bar) DP
Range. The case and bezel are 304 SST. The housings are
forged brass (steel and SST optional) with 1/4" x 1/4" NPT
connections. The bellows are BeCu or 316 SST, with an
Ethylene Glycol and Water Fill. The indicating accuracy is
±2.00 % of full scale. The unit can be pipe, wall, or
panel mounted.

Indicator Specifications
Temperature Limits -40˚F/˚C to +150˚F (+66˚C) 1502 Only
-40˚F/˚C to +180˚F (+82˚C) All Others
Accuracy 232C 0-50" w.c. to 0-100 PSID (0-124 mbar to 0-6.9 bar) ±2.00% F.S.
226C, 227C, 247C 0-30" w.c. to 0-50" w.c. (0-75 to 0-124 mbar) ±0.75% F.S.
0-51" w.c. to 0-60 psi (0-127 mbar to 0-4.1 bar) ±0.50% F.S.
0-61 psi to 0-150 psi (0-4.2 bar to 0-10.3 bar) ±0.75% F.S.
0-151 psi to 0-400 psi (0-10.4 bar to 0-27.6 bar) ±1.00% F.S.
0-601 psi to 0-400 psi (0-41.4 bar to 0-27.6 bar) ±4.00% F.S.
450C 0-30" w.c. to 0-400 psi (0-75 to 0-27.6 bar) ±1.00% F.S.
0-601 psi to 0-400 psi (0-41.4 bar to 0-27.6 bar) ±4.00% F.S.
Repeatability* ±0.25%

4
MEASUREMENT SYSTEMS

DP Switches

Model 288C Model 290D Model 318C Model 322C

Model 288C Model 318C


A 6-inch (152mm) indicating-switch that features a NEMA-4 A 4-1/2 inch (114mm) Indicating-Switch designed to meet
case with operating pressure ratings up to 6,000 psi (414 bar) MIL-S-901C Grade A and MIL-STD-167 Vibration standards —
and DP Ranges from 0-30" w.c. to 0-400 psi (0-75 mbar to used in US Navy Shipboard applications.
0-27.6 bar). Both single and dual switch units are standard, Model 322C
with up to two additional switches available as an option.
A blind DP switch that is housed in an explosion-proof case for
Also available in stainless steel (M288CS).
use in Class I, Div. 1, Group D hazardous areas. The standard
Model 290D unit comes with one SPDT switch.
An explosion-proof version of the 288C that is housed in a
CSA certified case (rated Class I, Div. 1, Groups B, C, & D) —
ideal for high shock and vibration environments.

Switch Specifications
Temperature Limits -40˚F/˚C to +150˚F (+66˚C) 1512 Only
-40˚F/˚C to +180˚F (+82˚C) All Others
Switches 1-4 SPDT Standard (DPDT and sealed switches optional)
Switch Contact Ratings AC 5 amps, up to 250V
DC Inductive = 1.0 amp up to 30 V
Resistive = 3.0 amps up to 30 V
(Other ratings/switches available)
Relays 1 or 2 DPDT Relays
Relay Ratings AC (Contact) Inductive = 5 amps up to 115VResistive = 10 amps up to 115V
AC (Coil) 6V, 12V, 24V, 115V = 5 VA maximum
DC (Contact) Inductive = 5 amps up to 26.5VResistive = 10 amps up to 26.5V
DC (Coil) 6V, 12V, 24V, 120V = 2W maximum
Indicating Accuracy (DP Range) SPDT 0-30" w.c. to 0-50" w.c. (0-75 to 0-124 mbar) ±1.25% F.S.
0-51" w.c. to 0-60 psi (0-127 mbar to 0-4.1 bar) ±1.00% F.S.
0-61 psi to 0-150 psi (0-4.2 bar to 0-10.3 bar) ±1.25% F.S.
0-151 psi to 0-400 psi (0-10.4 bar to 0-27.6 bar) ±1.50% F.S.
DPDT Add 0.5% to SPDT values
Point of Actuation ±10% of F.S. - Add 1/2% to SPDT values
Repeatability = 0.25% of full scale DP
Switch Deadband SPDT = ±5.0% max. F.S. DP
DPDT = ±6.0% max. F.S. DP
Suppressed Ranges Add 1/4%

5
Switch Contacts Relays
Switch models can be ordered with 1 to 4 adjustable snap- Some models can be ordered with 1 or 2 DPDT relays
acting type SPDT switches (DPDT and hermetically-sealed (mounted inside the case) for greater switching action and
switches available as specials on selected models). Switches can increased current handling capacity without the need for
be set for high, low, or both high and low on units with two external mounting or wiring.
or more contacts. Contacts are adjustable from 5 to 95% of
full scale and are set with a control screw located flush with
the scaleplate. Contacts can be set to open or close with
increasing or decreasing DP — providing maximum flexibility.

IT / ITS Transmitter/Switches Calibration


Indicating mechanism is driven directly Output calibration jacks are provided. The movement has a
off the process — independent of micrometer screw for convenient range adjustments. Zero
external power. Transmitter produces and range adjustments can be made without removing the
a 4-20 mA output. On ITS models, scaleplate or pointer. Linearity adjustments are readily
switches (either 2 or 4) can be used accessible after removal of the scaleplate.
SPDT or DPDT, with setpoints manually
On ITS, switch setpoints are adjustable by hand (with control
set to eliminate the need for calibration.
screw), no calibration equipment is required.
ITS switch specific applications include
Switch Options
on-off pump control and flow alarm.
Units are available with 2 or 4 fully-adjustable contacts that
IT / ITS models are actuated by the Model 224 DPU. can be set for high or low, or both high and low (when two
Operation contacts are furnished). By moving jumpers, two switches
The pointer movement is directly coupled to a precision can be made to operate simultaneously to give a DPDT switch.
potentiometer that develops the mechanical to electrical signal Jumpers can also be set to give ON-OFF control between
to drive the linear 4-20 mA output transmitter (IT / ITS only) two setpoints.
and switch (ITS only).

6
MEASUREMENT SYSTEMS

IT / ITS Specifications
Models IT 12 / ITS 20 / ITS 24
Temperature Limits Operating -40˚F/˚C to +180˚F (+82˚C)
Storage -40˚F/˚C to +200˚F (+93˚C)
Humidity to 95% R.H. @+104°F (+40°C)
Current Loop Supply Voltage (Min. to Max.) 14-30V DC*
Output Current 4-20 mA
Load Resistance 0-800 Ohms
*Either terminal 0 to +30VDC with respect to earth ground (green wire). Minimum voltage across
transmitter under conditions of maximum load and current (20 mA) 14 VDC.
Transmitter Maximum Turndown 2:1 (20 mA with pointer at 1/2 scale)
Accuracy (Pointer Indication)
includes line hysteresis, ±0.25% of F.S.
±0.2%/10% supply change
±0.1%/100 Ohm change
Internal Battery (ITS Only) Voltage 6 VDC
Size (2) Lithium C-Cells (Switch Only)
Life 10 years (w/loop power)
Switch (ITS Only) Accuracy ±1/0% F.S.
Repeatability ±0.2% F.S.
Deadband Adjustable1% to 9% of F.S.
Setpoints 2 or 4 Independent0 to 100% F.S. (pointer indication)
Contacts 2 or 4 SPDT2 Amp @30 VDC1 Amp @125 VAC
Indicator Accuracy 0-30" w.c. to 0-50" w.c. (0-75 to 0-124 mbar) ±0.75% F.S.
0-51" w.c. to 0-60 psi (0-127 mbar to 0-4.1 bar) ±0.50% F.S.
0-61 psi to 0-150 psi (0-4.2 bar to 0-10.3 bar) ±0.75% F.S.
0-151 psi to 0-400 psi (0-10.4 bar to 0-27.6 bar) ±1.00% F.S.
Repeatability 0.25%
Mounting Pipe, Wall, or Panel
Scales White or Black (uniform or square-root)
DP Ranges See 224C Specifications
Ordering Information When ordering please specify Unit Type (Case assembly or kit)
Quantity
Model Number
Housing Pressure Rating (SWP)
Housing Material
Bellows Material
Material Contacting Bellows
Differential Pressure Range
Type of Scale (Uniform or Sq. Rt.)
Scale Graduations
Mounting (pipe, wall, flush panel)
Note: Pipe mounting only on Explosionproof models

7
752 / 753 Explosion-proof Electronic Transmitters

Model 752 Model 753

For liquid, gas, or vapor service, both models feature a liquid- Transmitter Operation
tight, explosion-proof case (no aluminum). Any calibrated Silicon piezo-resistive strain gauges, carefully matched for delta
range, including absolute variations, is available as standard resistance and temperature coefficients to ensure linearity and
within the stated ranges. Units are insensitive to normal stability, are molecularly bonded (no organic compounds) on
vibration and shock, with the best available zero stability. opposite sides of the beam.
Zero and Span adjustments are easily accessible.
M752: The end of the strain gauge beam is secured inside a
• No RFI Generation (All DC circuitry) cutout in the shaft connecting the two bellows of the DPU.
• Outstanding Temperature Stability Input variations across the bellows cause a linear motion of the
• Independent, limited interacting Range and Zero controls bellows, which deflects the strain gauge beam proportionally.
• Model 752 can be ordered with zero center or split ranges.
M753: Input pressure variations cause the bourdon tube
• Model 753 overpressure to 150% of pressure range
to change shape, which in turn bends the cantilever
without damage; Model 752 up to SWP.
beam proportionally.
• Alloy Steel (cadmium plated) Case and Brackets
• Local Indicator Option The change in deflection of the beam is sensed by the strain
gauge and is converted into a resistance change. The tension
Model 752 gauge increases in resistance and the compression gauge
The 752 DP Electronic Transmitter delivers 1/2% accuracy with decreases in resistance in direct proportion to the deflection of
standard ranges from 0-50" w.c. to 0-300 psid. The 752 can the cantilever beam.
handle static pressures to 3,000 psig on standard models, with
The tension and compression gauges form two active elements
6,000 psig capacities available on special order.
of a wheatstone bridge network. The transmitter electronics
Model 753 condition and convert the bridge output signal to a 4-20 mA
The 753 couples the reliability of a bourdon tube with the or 10-50 mA output signal.
sensitivity of a silicon strain gauge to deliver 1/2% accuracy for
measurements from 0-25 psi to 0-5,000 psi.

8
MEASUREMENT SYSTEMS

752 / 753 Specifications


Accuracy ±0.50% of rating span (includes linearity, hysteresis, and repeatability)
±0.25% accuracy optional
DP Ranges M752 0-50" w.c. to 0-300 psid (max.)
consult factory for other ranges.
M753 0-25 psig to 0-5,000 psig
(others on special request)

SP Limit (M752) 3,000 psig standard


6,000 psig optional

Static Pressure Effect (M752) ±0.20% max. of rated span per 1,000 psig change.

Ambient Temperature Effect Zero and Span ±1.0% per 100°F over the range of +40°F to +135°F standard (-15°F to +135°F optional)

Storage Temperature Limits -25°F to +150°F standard

Electrical Output 4-20 mA or 10-50 mA


Power 12 to 70 VDC (per load)
Load Range See load graph
Supply Effect ±0.025% of calibrated span for ±1V power supply change
Load Effect ±0.025%/100 Ohms change for 4-20 mA
±0.065%/100 Ohms change for 10-50 mA
Sensitivity 0.01% of calib. span
Zero Control 50% suppression of rated span
Span Control 20-100% (rated span)

Physical Pressure Boundry O-rings (M752 only) Viton or EPT standard


Case Sealing O-rings Buna-N (standard); EPT or Viton optional
Fill Fluid Silicone Oil
Paint Baked polyvinyl chloride (standard)
Amerlock Gray optional
Electrical Connections 1/2" conduit (external junction box optional)
Basic Config. Weight (approx.) M752 - 14 lbs
M753 - 8 lbs

M752 Process Connections 1/4" NPT/1/2" NPT on 2-13/16" centers or


(B) 9/16-18 Aminco both sides on 2-13/16" centers
Materials Bellows, centerblock, & plugs - 316 SST (standard)
Pressure Housings - 316 SST or Carbon Steel

M753 Process Connections 1/4" NPT


Materials Bourdon Tube - Haynes Alloy 25
Pressure Connection - 316 SST

9
Dimensions – M226C

Dimensions – M227C

10
MEASUREMENT SYSTEMS

Dimensions – M232C

Dimensions – M288C

11
Dimensions – M290D

Dimensions – M316C / 318C

12
MEASUREMENT SYSTEMS

Dimensions – M322C

Dimensions – M450C / 450C SST

450C SST Version

13
Dimensions – IT / ITS (Weather-proof)

Dimensions – IT / ITS (Explosion-proof)

14
MEASUREMENT SYSTEMS

Dimensions – M752

Dimensions – M753

15
MEASUREMENT SYSTEMS

Weights GROSS WEIGHT (approximate) in lbs (kg)

Safe Working Pressure (psi)

MODEL 100 500 1000 1500 3000 6000

Differential Pressure Units (DPUs)

224C N/A 3.5 (1.6) Forged Brass 4.5 (2) 4.5 (2) 6.5 (2.9) 6.5 (2.9)
4.5 (2) CS / SST
Instruments (Includes DPUs)

226C N/A 4 (1.8) Forged Brass 5 (2.3) 5 (2.3) 7 (3.2) 7 (3.2)


5 (2.3) CS / SST
227C N/A 6 (2.7) Forged Brass 7 (3.2) 7 (3.2) 9 (4.1) 9 (4.1)
7 (3.2) CS / SST
246c / 247C N/A 17 (7.7) Forged Brass 18 (8.2) 18 (8.2) N/A N/A
18 (8.2) CS / SST
288C N/A 9 (4) 9 (4) 10 (5) 10 (5) 12 (5)
290D N/A 22 (10) 22 (10) 23 (10) 23 (10) 25 (11)
316C N/A 5.5 (2.5) Forged Brass 6.5 (2.9) 6.5 (2.9) 8.5 (3.9) 8.5 (3.9)
6.5 (2.9) CS / SST
318C N/A 9 (4) 9 (4) 10 (5) 10 (5) 12 (5)
322C N/A 9 (4) 9 (4) 10 (5) 10 (5) 12 (5)
450C N/A 6.25 (2.8) Forged Brass 7.25 (3.3) 7.25 (3.3) 9.25 (4.2) 9.25 (4.2)
7.25 (3.3) CS / SST
IT / ITS N/A 9 (4) 9 (4) 10 (5) 10 (5) 12 (5)
Weather-proof

IT / ITS N/A 22 (10) 22 (10) 23 (10) 23 (10) 25 (11)


Explosion-proof

752 Base Configuration – 14 lbs. (6.4)


753 Base Configuration – 8 lbs. (3.6)

Note: Contact Cameron for models not listed.

Disclaimer: This information is being provided for marketing


purposes only. Exact specifications should be confirmed with
the factory at time of order.

MEASUREMENT SYSTEMS

HOUSTON 2 81 . 582. 9500 NORTH 1. 800. 65 4 . 3 7 6 0 ASIA +603.2287.1039 EUROPE, + 4 4 . 1 2 4 3 .8 2 6 7 4 1


HEAD OFFICE AMERICA PACIFIC MIDDLE EAST
ms-us @ c-a-m.com [email protected] & AFRICA [email protected]

USA • CANADA • UK • SCOTLAND • CHINA • UAE • ALGERIA • M A L AY S I A • INDIA • K E N YA • w w w. c - a - m . c o m / f l o