Barton 316c 318c DP Indicator Switch
Barton 316c 318c DP Indicator Switch
Barton 316c 318c DP Indicator Switch
B A RT O N ®
DP Indicators, Switches
& Transmitters
Model 224C (Dual Bellows) upon their number and strength. They have extremely low
hysteresis and exceptional temperature stability. The M224
The 224C DPU is a lightweight compact sensor that
range springs are part of the BUA — they are not individually
incorporates a rupture-proof bellows in a common-head
replaceable parts.
design housing. It has an exceptionally fast response time, is
self-draining, and has built-in temperature compensation. Model 224C with NACE-complaint materials are available
upon special request.
The 224C DPU consists of a Bellows Unit Assembly (BUA) and
removable pressure housings. Within the BUA, flexible bellows
are secured to a centerplate. In dual-bellows models, the Special Configurations
movable bellows are rigidly connected by a dual valve stem Model 224C Absolute Pressure
that passes through the centerplate. Valve seats, in the A special version of the M224C provides direct measurement
centerplate passage, form a seal with the valves. Contacting of absolute pressure — eliminating the effects of varying
the valve stem in the centerplate is a drive arm pivoted on the atmospheric pressure. The LP bellows assembly is enclosed
end of a sealed torque tube. The bellows is filled with a clean, within a capsule. This capsule is evacuated to a very low level
noncorrosive, low-freezing point liquid. A range spring of absolute pressure and then hermetically sealed. Process
assembly provides tension against applied pressures. pressure applied to the HP housing is compared with the
established atmospheric pressure in the LP side, which provides
In operation, pressure is applied to both sides of the bellows.
a reference as close to “absolute zero” as possible. The
Any difference in pressure causes the bellows to move until
capsule is further contained within a housing that does not
the spring effect (range springs) balances out the force. The
have pressure ports. The HP housing has both top and bottom
linear motion of the bellows (proportional to the DP) is
ports for process connection, or for automatic draining of
transmitted as a rotary motion through the torque tube.
fluids or venting of gases.
In dual-bellows units, if the bellows are subjected to a DP
Model 224C Seal-Welded
greater than the unit’s DP rating, a valve closes and “traps”
the fill liquid in the bellows — fully supporting the bellows For applications requiring ZERO LEAKAGE, a special seal-
and preventing rupture. Since opposing valves are used, full welded M224C is available — a heliarc-welded joint replaces
protection is provided in either direction. the elastomer O-ring. This leak-proof metering is ideal for
applications involving hazardous fluids (e.g., N2O2, radioactive
water, toxic chemicals, etc.), as well as hard to seal gases like
Components
helium and hydrogen.
Bellows Construction - Individual diaphragms, stamped and
formed from selected materials, are assembled using highly
Features
specialized techniques, the results — exacting linearity
• All-welded chambers for process fluids
characteristics, a long cycle life, and freedom from effects of
work hardening commonly encountered with the hydraulically • Leak-tested at factory with Helium Mass-spectrometer
formed or mechanically rolled types. • DP Ranges from 0-30" w.c. to 0-400 psi
(0-75 mbar to 0-27.6 bar)
Torque Tube - eliminates possibility of leakage and need for
• SWP from 500 psi to 6,000 psi (34 bar to 414 bar)
lubrication. The needle bearing (inboard end) and ball bearing
• 316 SST Housing/Centerplate Material
(on follower drive arm) operate with a minimum of friction —
• 316 SST or Inconel Bellows Material
resulting in high sensitivity over the life of the unit.
For general specifications (not listed above), see Table 1
The torque tube assembly consists of a tube, shaft, and
on page 3.
supporting members. The outboard end of the torque tube is
attached to the centerplate. The shaft passes through the External Sensors
center of the tube and is welded to the inboard end. Refer to the Sealed Sensors Bulletin for details on applications
Since its outer end is attached to the centerplate, the tube requiring external sealed sensors, such as corrosive, high
must twist when subjected to torque. The shaft, freely temperature and hazardous fluids.
supported at its outer end and attached to the tube and drive
arm at its inner end, rotates through the same angle as the
drive arm — the mechanical output of the DPU.
2
MEASUREMENT SYSTEMS
Stainless Steel or
Beryllium Copper Bellows (224C Only) Inconel Bellows
SWP psi (bar) Housing Material Inconel Bellows Top Bottom
1-5/8" (41mm) O.D. 1-5/8" (41mm) O.D. 3/4" (19mm) O.D. 3/4" (19mm) O.D. 5/8" (16mm) O.D.
500 Forged Brass 0-30" w.c. (0-75 mbar) to 0-61 psi (0-4.2 bar) to
1/4" NPT 1/4" NPT
(34) (ASTM-B124#2) 0-60 psi (0-4.1 bar) 0-400 psi (0-27.6 bar)
500 Cold Rolled Steel (C1018) 0-30" w.c. (0-75 mbar) to 0-61 psi (0-4.2 bar) to
1/4" NPT 1/4" NPT
(34) Stainless Steel (316) 0-60 psi (0-4.1 bar) 0-400 psi (0-27.6 bar)
(69) (MIL-C-15726)
224C
Net Volume L.P. Head 1.66" (27.2 cc) 1.66" (27.2 cc) 2.51" (41.1 cc) 2.51" (41.1 cc) 2.61" (42.8 cc)
cu.in. (cu. cm) H.P. Head 1.55" (25.4 cc) 1.55" (25.4 cc) 2.42" (39.7 cc) 2.42" (39.7 cc) 2.50" (40.9 cc)
Displacement cu.in. (cu. cm) for full-scale Travel 0.14" (2.3 cc) 0.14" (2.3 cc) 0.03" (0.49 cc) 0.03" (0.49 cc) 0.025" (0.41 cc)
Performance: Torque Tube Rotation = 8° ±10%; Torque Tube Material = Beryllium Copper (BeCu); Temperature Limits = -40°F/°C to +180°F (+82°C); Maximum Non-linearity = per Range;
Repeatability = 0.2% of full scale differential pressure (see DP Indicators, Switches, & Transmitters bulletin #21920 for additional information).
Notes: Zero center or split ranges available on special order (e.g., 0-60" w.c. (0-149 mbar) range may be ordered 30-0-30" w.c. (75-0-75 mbar) or (15-0-45" w.c. (37-0-112 mbar). Absolute pressure ranges available
from 30" w.c. (75 mbar) to 600 psi (41.4 mbar). Other sizes and types of connections (welding stubs, MA, A.N.D., etc.) available upon request. Outline dimension drawings available upon request. Metric conversions ( )
are approximate. M224C with NACE (MR-01-75) compliant materials available upon request. Model 224 (Non-C) for specific Nuclear/Government applications only.
3
DP Indicators
Model 226C Model 227C Model 232C Model 247C Model 450C
Indicator Specifications
Temperature Limits -40˚F/˚C to +150˚F (+66˚C) 1502 Only
-40˚F/˚C to +180˚F (+82˚C) All Others
Accuracy 232C 0-50" w.c. to 0-100 PSID (0-124 mbar to 0-6.9 bar) ±2.00% F.S.
226C, 227C, 247C 0-30" w.c. to 0-50" w.c. (0-75 to 0-124 mbar) ±0.75% F.S.
0-51" w.c. to 0-60 psi (0-127 mbar to 0-4.1 bar) ±0.50% F.S.
0-61 psi to 0-150 psi (0-4.2 bar to 0-10.3 bar) ±0.75% F.S.
0-151 psi to 0-400 psi (0-10.4 bar to 0-27.6 bar) ±1.00% F.S.
0-601 psi to 0-400 psi (0-41.4 bar to 0-27.6 bar) ±4.00% F.S.
450C 0-30" w.c. to 0-400 psi (0-75 to 0-27.6 bar) ±1.00% F.S.
0-601 psi to 0-400 psi (0-41.4 bar to 0-27.6 bar) ±4.00% F.S.
Repeatability* ±0.25%
4
MEASUREMENT SYSTEMS
DP Switches
Switch Specifications
Temperature Limits -40˚F/˚C to +150˚F (+66˚C) 1512 Only
-40˚F/˚C to +180˚F (+82˚C) All Others
Switches 1-4 SPDT Standard (DPDT and sealed switches optional)
Switch Contact Ratings AC 5 amps, up to 250V
DC Inductive = 1.0 amp up to 30 V
Resistive = 3.0 amps up to 30 V
(Other ratings/switches available)
Relays 1 or 2 DPDT Relays
Relay Ratings AC (Contact) Inductive = 5 amps up to 115VResistive = 10 amps up to 115V
AC (Coil) 6V, 12V, 24V, 115V = 5 VA maximum
DC (Contact) Inductive = 5 amps up to 26.5VResistive = 10 amps up to 26.5V
DC (Coil) 6V, 12V, 24V, 120V = 2W maximum
Indicating Accuracy (DP Range) SPDT 0-30" w.c. to 0-50" w.c. (0-75 to 0-124 mbar) ±1.25% F.S.
0-51" w.c. to 0-60 psi (0-127 mbar to 0-4.1 bar) ±1.00% F.S.
0-61 psi to 0-150 psi (0-4.2 bar to 0-10.3 bar) ±1.25% F.S.
0-151 psi to 0-400 psi (0-10.4 bar to 0-27.6 bar) ±1.50% F.S.
DPDT Add 0.5% to SPDT values
Point of Actuation ±10% of F.S. - Add 1/2% to SPDT values
Repeatability = 0.25% of full scale DP
Switch Deadband SPDT = ±5.0% max. F.S. DP
DPDT = ±6.0% max. F.S. DP
Suppressed Ranges Add 1/4%
5
Switch Contacts Relays
Switch models can be ordered with 1 to 4 adjustable snap- Some models can be ordered with 1 or 2 DPDT relays
acting type SPDT switches (DPDT and hermetically-sealed (mounted inside the case) for greater switching action and
switches available as specials on selected models). Switches can increased current handling capacity without the need for
be set for high, low, or both high and low on units with two external mounting or wiring.
or more contacts. Contacts are adjustable from 5 to 95% of
full scale and are set with a control screw located flush with
the scaleplate. Contacts can be set to open or close with
increasing or decreasing DP — providing maximum flexibility.
6
MEASUREMENT SYSTEMS
IT / ITS Specifications
Models IT 12 / ITS 20 / ITS 24
Temperature Limits Operating -40˚F/˚C to +180˚F (+82˚C)
Storage -40˚F/˚C to +200˚F (+93˚C)
Humidity to 95% R.H. @+104°F (+40°C)
Current Loop Supply Voltage (Min. to Max.) 14-30V DC*
Output Current 4-20 mA
Load Resistance 0-800 Ohms
*Either terminal 0 to +30VDC with respect to earth ground (green wire). Minimum voltage across
transmitter under conditions of maximum load and current (20 mA) 14 VDC.
Transmitter Maximum Turndown 2:1 (20 mA with pointer at 1/2 scale)
Accuracy (Pointer Indication)
includes line hysteresis, ±0.25% of F.S.
±0.2%/10% supply change
±0.1%/100 Ohm change
Internal Battery (ITS Only) Voltage 6 VDC
Size (2) Lithium C-Cells (Switch Only)
Life 10 years (w/loop power)
Switch (ITS Only) Accuracy ±1/0% F.S.
Repeatability ±0.2% F.S.
Deadband Adjustable1% to 9% of F.S.
Setpoints 2 or 4 Independent0 to 100% F.S. (pointer indication)
Contacts 2 or 4 SPDT2 Amp @30 VDC1 Amp @125 VAC
Indicator Accuracy 0-30" w.c. to 0-50" w.c. (0-75 to 0-124 mbar) ±0.75% F.S.
0-51" w.c. to 0-60 psi (0-127 mbar to 0-4.1 bar) ±0.50% F.S.
0-61 psi to 0-150 psi (0-4.2 bar to 0-10.3 bar) ±0.75% F.S.
0-151 psi to 0-400 psi (0-10.4 bar to 0-27.6 bar) ±1.00% F.S.
Repeatability 0.25%
Mounting Pipe, Wall, or Panel
Scales White or Black (uniform or square-root)
DP Ranges See 224C Specifications
Ordering Information When ordering please specify Unit Type (Case assembly or kit)
Quantity
Model Number
Housing Pressure Rating (SWP)
Housing Material
Bellows Material
Material Contacting Bellows
Differential Pressure Range
Type of Scale (Uniform or Sq. Rt.)
Scale Graduations
Mounting (pipe, wall, flush panel)
Note: Pipe mounting only on Explosionproof models
7
752 / 753 Explosion-proof Electronic Transmitters
For liquid, gas, or vapor service, both models feature a liquid- Transmitter Operation
tight, explosion-proof case (no aluminum). Any calibrated Silicon piezo-resistive strain gauges, carefully matched for delta
range, including absolute variations, is available as standard resistance and temperature coefficients to ensure linearity and
within the stated ranges. Units are insensitive to normal stability, are molecularly bonded (no organic compounds) on
vibration and shock, with the best available zero stability. opposite sides of the beam.
Zero and Span adjustments are easily accessible.
M752: The end of the strain gauge beam is secured inside a
• No RFI Generation (All DC circuitry) cutout in the shaft connecting the two bellows of the DPU.
• Outstanding Temperature Stability Input variations across the bellows cause a linear motion of the
• Independent, limited interacting Range and Zero controls bellows, which deflects the strain gauge beam proportionally.
• Model 752 can be ordered with zero center or split ranges.
M753: Input pressure variations cause the bourdon tube
• Model 753 overpressure to 150% of pressure range
to change shape, which in turn bends the cantilever
without damage; Model 752 up to SWP.
beam proportionally.
• Alloy Steel (cadmium plated) Case and Brackets
• Local Indicator Option The change in deflection of the beam is sensed by the strain
gauge and is converted into a resistance change. The tension
Model 752 gauge increases in resistance and the compression gauge
The 752 DP Electronic Transmitter delivers 1/2% accuracy with decreases in resistance in direct proportion to the deflection of
standard ranges from 0-50" w.c. to 0-300 psid. The 752 can the cantilever beam.
handle static pressures to 3,000 psig on standard models, with
The tension and compression gauges form two active elements
6,000 psig capacities available on special order.
of a wheatstone bridge network. The transmitter electronics
Model 753 condition and convert the bridge output signal to a 4-20 mA
The 753 couples the reliability of a bourdon tube with the or 10-50 mA output signal.
sensitivity of a silicon strain gauge to deliver 1/2% accuracy for
measurements from 0-25 psi to 0-5,000 psi.
8
MEASUREMENT SYSTEMS
Static Pressure Effect (M752) ±0.20% max. of rated span per 1,000 psig change.
Ambient Temperature Effect Zero and Span ±1.0% per 100°F over the range of +40°F to +135°F standard (-15°F to +135°F optional)
9
Dimensions – M226C
Dimensions – M227C
10
MEASUREMENT SYSTEMS
Dimensions – M232C
Dimensions – M288C
11
Dimensions – M290D
12
MEASUREMENT SYSTEMS
Dimensions – M322C
13
Dimensions – IT / ITS (Weather-proof)
14
MEASUREMENT SYSTEMS
Dimensions – M752
Dimensions – M753
15
MEASUREMENT SYSTEMS
224C N/A 3.5 (1.6) Forged Brass 4.5 (2) 4.5 (2) 6.5 (2.9) 6.5 (2.9)
4.5 (2) CS / SST
Instruments (Includes DPUs)
MEASUREMENT SYSTEMS