Gate Control
Gate Control
2114
Control panel for double motors up to 2400watt
Terminal Light
Code Frequency Codification Photocells Ext.Button Auto close Motor torque Slow move
Switches 230V
PSR/PTR-2114 433,92/868,3 Keeloq rolling YES YES YES YES YES YES YES
PS-2114 433,92 Standard YES YES YES YES YES YES YES
Profelmnet
PN-2114 433,92 YES YES YES YES YES YES YES
rolling
Check all connections. Check the terminal switches of the motor. The BLUE/GREY motor wire is connected in terminal 4.
WORKING TIME
CODE M1 M2
Νο Function description
TRANSFORMER CODE
RECEIVER RF
OFF: No photocell 1.
INDICATING LEDS CLOSE OPEN CLOSE OPEN 3
ON: Photocell 1. (On the door for safety and auto-close.)
FLASH M1 close Μ1 open Μ2 close Μ2 open LOCK
MOTOR 1 MOTOR 2
OFF: No auto close
ON: Auto-close. There is a double counter in the A/C
COMMON
COMMON
CLOSE
CLOSE
OPEN
OPEN
1 2 3 4 5 6 7 8 9 1011 12 12V 13 14 15 16 17 18 19 20 21 22 23
OFF:NO repeatable close.
6
ON: Repeatable close for 1 sec every 1 hour
24V
OFF: No key-lock
COMMON
PHOTOCELL 1
COMMON
PHOTOCELL 2
7
COMMON
+
CLOSE
L N ' 0
OPEN
OPEN
CLOSE
GND Ï ANTENNA
1+2
V.OUT
1
Functions
Motor torque for open function. If the photocell beam is cut-off, the door
both: never closes. Auto close: Select dip-switch 4 to activate it.
Adjust the motor torque There is a double counter in the A/C function. The first one
for both motors at ½ of is 120 seconds and is applied when the door stops after an
the total torque. open function. During this counting time of 120 sec., if the
Power supply 230V: photocell beam is disturbed, then after the beam is free,
Supply the control panel the A/C counting time becomes 10 sec. until the fully closed
with 230V.Check that the position.
yellow indication light is Motor delay:
ON. Press the button of the Motor 1 starts first and after 3sec., starts Motor 2
transmitter and check the
Repeatable close:
red indication light is ON.
The first shutter move after
Ιs used only in Hydraulic motors and activates instantly the
power-up (230V) is the Slow close routine every 1H.
OPEN direction, otherwise substitute open/close motor wires. Clear memory: The first step is to clear the rolling code
Working time: memory. Press the button CODE of the controller and the
BOTH SECTIONS OF THE DOOR ARE FULLY CLOSED. Press MOTOR RED light goes ON after a while. Keep it pressed until the
TIMER button M1 and keep it pressed until the first door section light goes off. The memory is now clear.
goes into the fully OPEN position, and leave it immediately. Press Adding a new transmitter with the controller button:
MOTOR TIMER button M2 for the second section of the swing door
Press the CODE button and the RED light goes on (after a
and also keep it pressed until the fully OPEN position too. Remove
power; place both sections in the fully closed position and power
small delay). Leave it and during the next 3 seconds, press
up. the desired transmitter channel button until the RED light
Motor direction (open-close): blinks and goes OFF. The new transmitter is saved. Follow
The MOTOR 1 (K7-8-9) is the motor that starts first from the closure the same procedure to program more (up to 20 or 80) new
position of the gate. After all connections are completed, move the transmitters.
both motors in the middle of the route manually. Power the control
Adding a new transmitter remotely: The motor is
panel with 230V. Using the button of timer M1 and M2, check the
indication lights to be ON. The movement of the motors needs to stopped. Press a working transmitter button (already in
be compatible with the function OPEN-CLOSE. If not, turn the wires memory) to start the motor working and hold it pressed
of the motor CLOSE-OPEN (K8/9) and (K11/12). After all until the motor stops. When it stops, leave it and press the
connections, close the gate manually. Turn off and turn on the new transmitter button immediately. The new transmitter is
power of the control panel in order to make RESET. saved. Repeat steps to program more transmitters
Deceleration: remotely. When the memory is full you cannot add more
During the Open/Close tests, adjust the DECELERATION new transmitters.
TIME so both sections go to a fully open or close positions.
Reset the automation: Case of malfunction, please
The position of the motor torque needs to be at ¼ of the
remove the power supply (230Vac) for 10 seconds,
turn.
reconnect and recheck.
External button:
1+2 activates both motors while external button 1 activates Compatible transmitters:
ONLY the motor 1. Based on the model you have, select the appropriate
Photocell power supply: transmitter.
Jumper 1 12V/24V.
Photocell 2:
(Κ15) stops the gates’ move immediately for how long the
photocell is activated.
Photocell 1:
(Κ17) works for protection and activates the auto-close.
When the door closes and the photocell beam is cut-off, the
door stops immediately and automatically activates the