Energies 13 06546 v2

Download as pdf or txt
Download as pdf or txt
You are on page 1of 19

energies

Article
A Coalitional Model Predictive Control for the Energy
Efficiency of Next-Generation Cellular Networks
Eva Masero 1, * , Luis A. Fletscher 2 and José M. Maestre 1
1 Department of Systems and Automation Engineering, Escuela Técnica Superior de Ingeniería,
Universidad de Sevilla, 41092 Seville, Spain; [email protected]
2 Department of Electronic Engineering and Telecommunications, Facultad de Ingeniería,
Universidad de Antioquia, 050010 Medellín, Colombia; [email protected]
* Correspondence: [email protected]

Received: 11 November 2020; Accepted: 9 December 2020; Published: 11 December 2020 

Abstract: Next-generation cellular networks are large-scale systems composed of numerous base
stations interacting with many diverse users. One of the main challenges with these networks is
their high energy consumption due to the expected number of connected devices. We handle this
issue with a coalitional Model Predictive Control (MPC) technique for the case of next-generation
cellular networks powered by renewable energy sources. The proposed coalitional MPC approach
is applied to two simulated scenarios and compared with other control methods: the traditional
best-signal level mechanism, a heuristic algorithm, and decentralized and centralized MPC schemes.
The success of the coalitional strategy is considered from an energy efficiency perspective, which
means reducing on-grid consumption and improving network performance (e.g., number of users
served and transmission rates).

Keywords: model predictive control; coalitional control; renewable energy; networked systems;
wireless network

1. Introduction
Large-scale systems such as telecommunication networks and power systems are comprised of
numerous lower-dimensional subsystems that inter-operate to achieve a common goal. The subsystems
are usually distributed over a wide geographical area, and it is necessary to develop control strategies to
guarantee optimal system performance. From the control viewpoint, the main challenges of large-scale
systems are to collect information from geographically distributed elements, coordinate control actions
taken by different types of agents, and handle the coupling between subsystems.
Mobile cellular networks are large-scale systems that are expecting exponential growth in 5G and
6G systems due to the increasing number of subscribers and mobile devices. Concerning [1], over 70%
of the global population will have mobile connectivity by 2023, and 5G devices and connections will
be over 10% of global mobile devices and connections by 2023. The consequences of such growth in
the demand for network capacity are also very well known. For the telecommunications industry,
this implies a need to increase infrastructure deployment for the core and Radio Access Network
(RAN), which means higher capital and operational expenditures. Note that the energy consumption
costs are crucial in the operational expenditures.
In the 5G roadmap, environmentally friendliness is a mandatory characteristic defined by the
International Telecommunication Union (ITU). In this sense, different alternatives have been studied
to increase energy efficiency in the network segments. For example, the Study Group 5 of ITU
Telecommunication Standardization Sector (ITU-T) is responsible for the environment and circular
economy recommendations, and it is developing a standard called "L.1380: Smart energy solution

Energies 2020, 13, 6546; doi:10.3390/en13246546 www.mdpi.com/journal/energies


Energies 2020, 13, 6546 2 of 19

for telecom sites" [2]. The ITU L.1380 objective is to describe techniques for the automated control of
power feeding from multiple energy sources, to improve energy efficiency and reduce operating costs,
e.g., using schemes that prioritize the intake of power from renewable energy sources.
Another critical issue is related to the energy consumption of the multi-functional user equipment
in 5G and beyond. In this scenario, the multiband, high processing, and ultra-reliability capacities
demand novel hardware solutions that facilitate cost-effective and energy-efficient user equipment
design [3]. Although this paper focuses on the user-BS association process, it is essential to note that
5G is an ecosystem where each element and process plays a significant role.
Previous studies have shown that cellular networks consume about 0.5% of the global energy
supply [4,5]. This phenomenon has motivated several kinds of research focused on reducing on-grid
consumption, e.g., Artificial Intelligence for Green Networks (AI4GREEN) [6] and Sustainable Cellular
Networks Harvesting Ambient Energy (SCAVENGE) [7]. A common conclusion is that Base Stations
(BSs) cause most on-grid consumption in cellular networks. Moreover, this consumption has a direct
relationship with the traffic load [8]. From the energy efficiency perspective, mobile networks can
be optimized by (i) redesigning the system to reduce energy consumption while achieving the same
goals [9], (ii) reducing the energy losses [10], and (iii) changing the energy source to one with lower
environmental impact [11,12]. In this paper, we focus on the energy sources and the optimization of
the energy management policy to reduce consumption.
In the last few years, renewable energies have been promoted as the energy source for BSs.
Various studies show that using renewable energy sources in Heterogeneous cellular Networks
(HetNets) reduces network costs [13–15] and improves environmental factors [16]. Another appealing
aspect is deploying infrastructure in off-grid and connection limited scenarios such as developing
countries and disaster zones. Therefore, Next-Generation Cellular Networks (NGCNs) can become
self-sustainable systems thanks to renewable energy sources [17].
The design of policies to reduce grid consumption in NGCNs is deeply connected with the
user-BS association algorithms [18] since it determines how the network uses its resources to serve
users. In the literature, it can be found several strategies to solve the load-balancing problem in HetNets.
For example, Andrews et al. [19] presented a survey of approaches for load-balancing in HetNets.
There is a need for exploring new load-balancing mechanisms because the problem of associating
users with BSs is Non-deterministic Polynomial-time hard (NP-hard) and may not be tractable even
for small-sized HetNets. From the energy efficiency perspective, Zhou et al. [20] proposed a heuristic
algorithm for target-cell selection combined with a power control algorithm for coverage optimization
to guide users towards BSs with renewable energy supply in the handover process. Likewise, Han and
Ansari proposed to optimize the use of renewable energy by cell-size optimization [21]. To this end,
they divided the problem into two parts: a multi-stage energy allocation problem, and a multi-BS
energy balancing problem. In [22], an off-line algorithm to optimize the renewable energy allocation
across different time instants was proposed to minimize the on-grid energy consumption of a base
station. In [23], the classic optimal-transportation approach to study the mobile association problem in
cellular networks was employed. In [24], a profit-driven user association scheme by jointly considering
the traffic delivery latency and renewable energy application was proposed to maximize the benefits
of network providers in HetNets. These approaches differ from our proposal, which considers that the
network structure can be dynamically clustered in sets of cooperating BSs (also known as coalitions) to
optimize consumption and coordination overheads with energy and traffic forecast information.
In the control field, Model Predictive Control (MPC) stands for a family of control methods
based on the receding horizon principle and can deal with multiple variables systems and complex
issues such as delay times, constraints, and uncertainties [25]. A system model is used to predict
its behavior, and the controller optimizes its evolution according to a specific cost function and the
given constraints. For example, in [26], an MPC was implemented to handle the power signal in
base stations and decrease the unfavorable influence of disturbances in the transmission process.
Moreover, co-channel interference via distributed power adaptation with MPC was reduced in [27].
Energies 2020, 13, 6546 3 of 19

Nevertheless, the significant computation burden required to solve a centralized MPC can make it
impossible or greatly difficult to implement in real time. For that reason, the divide-and-rule policy
of distributed MPC techniques has been widely established over the last few decades to deal with
large-scale problems [28]. A halfway approach is the coalitional MPC [29,30], which considers a
dynamic system partition to find a trade-off between local performance and coordination overheads.
Relevant challenges such as network and energy management appear when renewable energy
is used in NGCNs [31]. In this context, coalitional MPC becomes a suitable control strategy.
The motivation of this work is to provide an efficient controller that holds the quality of service
while reducing on-grid consumption. Moreover, the scalability of the method is also important to
deal with the large spatial distribution of cellular networks. Hence, the main contribution of the
article is to assess how Long-Term Evolution (LTE) systems powered by hybrid energy sources can
be more sustainable in a scalable manner by using coalitional MPC. Likewise, unlike other studies
such as [9,32,33], we propose a more realistic internal model for the controller that considers that the
transfer of users between base stations is limited to neighboring base stations.
Furthermore, the proposed coalitional approach is compared with the traditional best-signal-level
strategy, a reactive control scheme based on an energy-aware user-BS association mechanism [33]
and decentralized and centralized MPC methods. These strategies are tested in two simulated scenarios:
(i) an academic example with 9 BSs, and (ii) a complex scenario with 37 BSs. Results show that the
proposed control scheme becomes a suitable option to reduce on-grid consumption while maintaining
proper service levels to users.
Finally, a much earlier and shortened version of the proposed method was accepted for a
conference presentation [34]. There are significant differences between the current article and the
conference paper: (i) the conference version does not include the large scenario with 37 BSs, which
represents the complexity of real problems; (ii) we present here new, improved methods for the
selection of topology; (iii) a more realistic internal model for the controller is used that only considers
user transfer between neighboring base stations; (iv) several refinements in the main algorithm are
introduced in the current version; and (v) the experiments here performed are new and include the
previously mentioned novelties.
The outline of the rest of the article is as follows. The problem statement is described in Section 2.
The coalitional MPC algorithm and other assessed user-BS association techniques are detailed in
Section 3. The control schemes are assessed in two simulated scenarios in Section 4. Finally, the authors
discuss the results and give concluding remarks in Section 5.
Notation: N0+ and R>0 are, respectively, the sets of non-negative integers and positive real numbers.
Rn represents an n-dimensional set of real numbers. For set X , {1, . . . , X } ⊆ Rn , its cardinality is
|X| = X, and the subtraction of an element i ∈ X from X is denoted as X \ {i}. The modulo operation
is mod(a, b), with a, b being positive integers. Given a set C ∈ M, the generalized union of sets is
Ð
represented as C ∈M C.

2. Problem Description
Let us define a two-tier downlink HetNet as depicted in Figure 1, which is divided into
B = {1, 2, . . . , B} base stations: a high-power Macro-cell Base Station (MBS) and numerous low-power
Small-Cell Base Stations (SCBSs). In particular, the MBS is full-time available and connected to the
electricity grid, while each SCBS is locally fed by renewable energy and equipped with a storage
battery. Although primary coverage is provided by the MBS, the implementation of SCBSs broadens
the network capacity since they receive data traffic from the MBS.
For simplicity, we follow the setting of [35,36] so that the inter-BS interference is modeled as a
static value that includes the influence of other BSs in the network. This value varies depending on
the activities in the interfering BSs, which can be coordinated via time-domain, frequency-domain,
and power-control techniques [37]. Additionally, this simplification allows us to model the network as
an MBS and multiple SCBSs without lacking generality.
Energies 2020, 13, 6546 4 of 19

Electric Grid

Storage Wind
Solar Panel Turbine
System

Small Cell BS

Macro Cell BS

Figure 1. Scheme of a hybrid-energy heterogeneous cellular network.

2.1. Base Station Dynamics


The discrete-time dynamics of each base station i ∈ B is:
Õ
xi (k + 1) = Ai xi (k) + Bi j ui j (k) + wi (k), (1)
j ∈ Ci (k)

where k ∈ N0+ is the time instant; xi = [xiz , xib ]> is the state vector comprised by xiz , which represents
the users served by i, and xib , which is the energy stored in the battery of i. Input ui j is user flow,
i.e., the amount of users exchanged between i and j, which belongs to the set of subsystems cooperating
with i, namely Ci . Hence, it is satisfied that ui j = −u ji for i, j ∈ Ci , and ui j = 0 for all j < Ci . Moreover,
Ai is the state matrix, and Bi j is the input-to-state matrix from neighbors j ∈ Ci . The disturbance vector
wi ∈ R2 consists of the traffic generated by the incoming and outgoing users and the atmospheric
conditions that influence the production of renewable energy.

2.2. Coalition Dynamics


Each subsystem i ∈ B is governed by a local controller with partial information regarding the
overall system state. The set of controllers can cooperate in a topology network described by an
undirected graph (B, L), where L is the set of links or edges L ⊆ L B = {i, j}|{i, j} ⊆ B, i , j .


Each link provides a bidirectional information flow between BSs i and j that can be enabled or
disabled by the control scheme. Each enabled link involves a fixed cooperation cost clink ∈ R>0 , which
will be selected large enough to stimulate cooperation, considering that a small value and a huge
value will always lead to a centralized and a decentralized network, respectively. The active links
L ≤ |L| define the network topology Λ ∈ T at time instant k. The set of all possible topologies is
T , {Λ0 , Λ1 , . . . , Λ2|L|−1 }, where the decentralized topology is Λdec = Λ0 and the centralized one is
Λdec = Λ2|L|−1 . Should there be a substantial number of links, a subset of topologies can be considered
to avoid combinatorial explosion issues.
Thanks to the capacity of the MBS to deal with all incoming users (at the cost of reducing its
quality of service), coalition problems can be decoupled. Given topology Λ, the disjoint set of coalitions
is represented as B/Λ with C ∈B/Λ C = B. The discrete-time dynamics of each coalition C is:
Ð

Õ
x C (k + 1) = A C x C (k) + B C u C (k) + w C (k), (2)
j ∈ C(k)

where x C = (xi )i ∈ C and u C = (ui j )i,j ∈ C are, respectively, the aggregated state and input vectors of all
base stations in C, and disturbance w C represents disturbances caused by the effect of the weather and
the coupling with neighboring coalitions.
Energies 2020, 13, 6546 5 of 19

2.3. Energy Consumption Model


The energy consumption model here employed was proposed by project EARTH and has been
widely used in studies related to energy efficiency in cellular networks [35,38,39]. According to EARTH,
the energy consumed by base station i ∈ B is given by dynamic and static energy consumption as
in [8]:
Ei (k) = ∆i δi (k)Ti + EiS , ∀i ∈ B, (3)

where ∆i is the slope of the load-dependent energy consumption; δi denotes the traffic load; Ti is
the transmission power; and EiS is the static energy consumption, which is relevant to the amount
demanded for the appropriate operation of a base station. Note that the dynamic energy consumption
is the additional energy required to cope with the traffic load.
Since the total consumption is the sum of the on-grid consumption of the MBS (i = 1) and the
renewable energy consumption of all SCBSs i ∈ B\{1}, the reduction of grid consumption is crucial to
increase energy efficiency. Finally, the available renewable energy EiG in SCBS i at time instant k is:

EiG (k) = EiG (k − 1) − Ei (k − 1) + ϕ(k), (4)

where EiG (k − 1) and Ei (k − 1) are, respectively, the stored and consumed renewable energy at time
instant k − 1, and ϕ(k) is the renewable energy generation rate at time instant k.
One of the main issues of renewable energy is the management of the stored energy, especially
how to maintain appropriate quality of service levels according to renewable energy availability.
In this sense, it is crucial to design a mechanism that guarantees the continuity of the service in periods
without renewable energy arrival.

2.4. Data Traffic Model


Let us define the geographical area A where BSs are spatially distributed at positions p ∈ A and a
set of available base stations Bz (k) ⊆ B that provides service to user z ∈ Z , {1, 2, . . . , Z } at time
instant k. The spatial variability of traffic requests is considered and modeled as a Non-Homogeneous
Poisson Process (NHPP) as in [36]. The traffic size, the arrival rate per area λ p , and the average traffic
size µ p for all p are independently distributed.
p
The transmission rate rzi of a mobile user z ∈ Z can be generally calculated according to the
Shannon–Hartley theorem [36] as:
p p
rzi (k) = BW i log2 1 + ψzi (k) , ∀z ∈ Z, i ∈ Bz (k), p ∈ A,

(5)
p
with BW i being the working bandwidth for all i ∈ Bz (k); and ψzi being the received signal at location p
from i, which is given by the Signal-to-Interference-plus-Noise Ratio (SINR) as:
p
p Ti gi
ψzi = p, ∀i, j ∈ Bz (k), (6)
σ2 +
Í
Tj g j
j ∈Bz \{i }

where Ti is the transmission power of i; the channel gain between BS i and the user at position p is
p
gi , which captures the slow fading signal containing path loss and shadowing; and finally, σ 2 is the
noise power level. Notice that the denominator depicts the interfering BSs transmission towards user
p
z at location p as Gaussian noise. Moreover, ψzi must be higher than a threshold ψmin so that user z
has enough signal level and can be associated with i. For simplicity, the location indicator p will be
omitted when referring to user z.
Each SCBS i ∈ Bz \{1} is assumed to serve a fixed number zimax of users simultaneously. Conversely,
the service is full-time guaranteed because the MBS offers an unlimited user service. Considering
users uniformly distributed in A, the traffic load δi is:
Energies 2020, 13, 6546 6 of 19

Í
 z ∈Z yzi (k)
, ∀i ∈ Bz (k)\{1}


 max
δi (k) = Í zi


(7)
z ∈Z yzi (k)
, otherwise




 |Z|

where yzi represents the user association indicator, i.e., yzi = 1 when user z is attended by i and yzi = 0
otherwise. Additionally, the traffic load is bounded by 0 ≤ δi (k) ≤ 1 for all i ∈ Bz (k).

2.5. On-Grid Energy Consumption Optimization Problem


Reducing on-grid consumption is a design requirement in NGCNs. Regarding Equation (3),
the energy consumption of i ∈ B depends on traffic load δi , i.e., the number of active users
connected to a base station. Let us define the vector of MBS-user association indicators as
Yz1 (k) , [y11 (k), . . . , y Z1 (k)]. The objective is to minimize the number of users connected to the MBS as:

N Õ
Õ
Yz1 (k) = arg min

yz1 (k), (8a)
Yz1 (k)
k=1 z ∈Z

subject to
Õ
yzi (k) ≤ zimax , ∀i ∈ B\{1}, (8b)
z ∈Z

yzi (k) · ψzi (k) p ≥ ψmin , ∀z ∈ Z, i ∈ Bz (k), (8c)


Õ
yzi (k) ≤ 1, ∀z ∈ Z, (8d)
i ∈B

yzi (k) ∈ {0, 1}, ∀z ∈ Z, i ∈ B, (8e)

where k ∈ [1, N] ∩ N0+ with N being the simulation length, Equation (8a) is the cost function to
minimize, and inequality Equations (8b)–(8e) are the problem constraints: Equation (8b) establishes
that SCBSs can serve a maximum of zimax users simultaneously; Equation (8c) is the user’s received
signal level constraint; Equation (8d) requires that a user is served only by one BS in a time instant;
and finally, Equation (8e) establishes that yzi is a binary variable. Note that the optimization problem
is solved according to the specific network characteristics at each time instant k. This fact allows
considering the variability of renewable energy sources in the solution.
The optimization problem Equation (8a) is a Mixed-Integer Linear Problem (MILP), a well-known
N P-hard problem [40]. The coalitional MPC control strategy proposed in this paper relaxes this
problem to provide a suitable alternative to achieve a sub-optimal solution with reduced computation
and cooperation burden. The next section shows how user-BS association decisions are made by a
supervisory controller, which relates the number of users at the BS with the corresponding battery level.
Thus, users will be initially associated with their closest base station. Later on, sets of cooperating BSs
will decide whether to exchange users to obtain a trade-off between energy efficiency and service levels.

3. Control Methods
This section details the proposed coalitional MPC algorithm and other assessed methods:
(i) centralized and decentralized MPC, which provide, respectively, an upper and lower bound of the
performance; (ii) an energy-aware heuristic method; and (iii) the best-signal-level technique, which is
a well-known user BS-association strategy. Unlike other studies such as [9,32,33], we here propose a
more realistic internal model for the controller that considers that the transfer of users between base
stations is limited to neighboring base stations.
Energies 2020, 13, 6546 7 of 19

3.1. Coalitional MPC


This strategy promotes dynamic cooperation between local controllers to improve coordination,
giving rise to the so-called coalitions, which implement an MPC controller to calculate the most
appropriate control actions at the coalition level and optimize the overall system performance. At each
time instant, optimal inputs are calculated for a prediction horizon of Np time steps according to a cost
function. The first component of the optimal input sequence is applied, and the remaining elements
are then discarded. This procedure can be depicted as a sliding window optimization process over
time because it is repeated at each time instant [28].
For the centralized control, the problem is solved by a single agent with full information.
Nevertheless, this setup scales very poorly due to the increase of the computational burden with
the problem size. By contrast, non-centralized architectures are often preferred due to to their inherent
redundancy in the decision making process. One possible solution is to solve the centralized problem
in a distributed fashion using distributed algorithms, but this can only be done at the expense of
increasing the cooperation effort, which can be measured in terms of computation and communication
burden. In general, the more agents involved in a negotiation, the more iterations required to attain an
agreement. Hence, one may be willing to pay a cost in terms of performance if the cooperation burden
can be decreased. To this end, we introduce a communication cost penalty in the problem setup.
Each communication link l ∈ L, which involves a cost clink ∈ R>0 , can be either enabled or
disabled. Note that the role played by this cost is crucial in this context. Otherwise, there would
be no incentive to disable links, and full communication would be used because it provides the
best control performance. However, this latter fact may cause the overall control problem to be
significantly large to be solved in real-time, and the use of specific links is restricted due to the energy
consumption constraints.
The objective of coalition C is to optimize the cost function J C ·), which is the sum of a stage cost
function l C x1z (k) and a penalty function, at each time instant k:


 NÍp −1
J C x1z (k), δ C (k) = x1z (k + t)> Qx1z (k + t) +δ C (k + t)> α C δ C (k + t),
t=0 | {z } (9)

lC x1z (k)

where x1z (k + t) is the amount of users served by the MBS at the corresponding time slot t of the
prediction horizon; Q > 0 is a constant weighting parameter that penalizes the number of users at the
MBS; α C ∈ R+ is a weighting parameter; and δ C (k + t) is a slack variable used as a soft constraint.
The proposed coalitional MPC algorithm presents a hierarchical control architecture [29], where an
upper layer computes the best new topology every Tup instants, considering the current disturbances.
Specifically, it explores the set of potential successor topologies Tnew ⊆ T with a search strategy to
select the new topology. The set Tnew is formed by those topologies Λ ∈ T that only differ one link
with respect to the current topology Λcur , i.e., those whose Hamming distance is one, as follows:

Tnew , {Λ ⊂ Λcur : |Λ| = |Λcur | − 1} ∪ {Λcur ⊂ Λ : |Λ| = |Λcur | + 1}. (10)

Once the topology Λnew ∈ Tnew is selected, it is sent to the lower control layer where coalitions
must be formed in accordance with this topology.
Let us define the vector of user flow of coalition C ∈ B/Λ as:

U C (k) , [u C (k), u C (k + 1), . . . , u C (k + Np − 1)].

The objective is to minimize the user flow from coalition C to the MBS at each time instant k:
Energies 2020, 13, 6546 8 of 19

{U C (k)∗ , δ C (k)∗ } = arg J C x1z (k), δ C (k) ,



min (11a)
UC (k),δC (k)

subject to Equation (2) and:

Õ
ui,j (k + t) ≤ Fi,j (k + t), t = 0, . . . , Np − 1, (11b)
i,j ∈ C
Õ
ui,j (k + t) = xiz (k + t), i ∈ B, t = 0, . . . , Np − 1, (11c)
j ∈C

ui,j (k + t) ≥ 0, i, j ∈ B, t = 0, . . . , Np − 1, (11d)
δ C (k + t) ≥ 0, ∀i ∈ C, t = 0, . . . , Np − 1, (11e)
x C (k + t) + δ C (k + t) ≥ 0, t = 1, . . . , Np , (11f)
x C (k + t) + δ C (k + t) ≤ gxC , t = 1, . . . , Np ,

G xC (11g)

where Equation (11b) indicates that the sum of user flows between two BSs cannot pass an upper
limit; Equation (11c) imposes flow conservation, that is that the sum of user flows must be equal to
the served users xiz ; Equation (11d) and Equation (11e) define, respectively, that user flows and the
slack variable must be positive; Equation (11f) imposes that the sum of the state vector and slack
variable must be positive; and finally, limits G xC and gxC define a convex set containing the origin in its
interior, i.e., Equation (11g) constrains the number of users served and the battery level of SCBSs as
0 ≤ xiz ≤ zimax and 0 ≤ xib ≤ bmax
i , respectively.
Finally, the proposed Algorithm 1 is summarized as follows.

Algorithm 1: Coalitional MPC.


Initial data: N, Tup , Q, Fi,j , zimax , bmax
i , clink , α C .
Starting point: k = 0, Λ = Λcen , xi = xi (0).
Main program:
for k ≤ N − 1 do
if mod (k, Tup ) = 0 then
1: The upper control layer measures states x C (k) and disturbances w C (k), ∀C ∈ B/Λ.
2: The upper layer computes the set Tnew (Equation (10)) and solves Equation (11) subject
to Equation (2) for each Tnew ⊆ T . Afterwards, the topology Λ ∈ Tnew with the lowest cost
is selected.
3: Send the new topology Λ to the lower control layer.
4: Apply the first element of U C∗ (k) to coalition system (Equation (2)), for all C ∈ B/Λ.
else
5: In the lower layer, each coalition C solves Equation (11) subject to its dynamics and
constraints.
6: Apply the first element of U C∗ (k) to coalition system (Equation (2)), and obtain x C (k + 1),
∀C ∈ B/Λ.
end if
7: Set k ← k + 1.
end for

3.2. Centralized and Decentralized MPC


In centralized MPC, full communication is enabled, and hence, there is only one cooperation
component C = B. The discrete-time dynamics of the overall system is:
Õ
x B (k + 1) = A B x B (k) + B B u B + w B (k). (12)
j ∈B
Energies 2020, 13, 6546 9 of 19

Therefore, Equation (11) is computed each k for the great coalition C = B. Since there is full
system information, the sheer performance is better than coalitional control. However, this technique
needs full cooperation each time instant, leading to a higher computation burden and cooperation
costs, which may hinder its implementation.
Conversely, when there is no cooperation between agents, Equation (11) is solved for C = {i},
∀i ∈ B at each time instant k. This fact occurs in decentralized MPC, where each coalition is formed by
a single local controller that manages each base station (Equation (1)). A lack of full information leads
to worse performance than a coalitional strategy at the expense of reducing the computation burden.

3.3. Energy-Aware Heuristic


In [33], the authors proposed a renewable energy-aware user equipment-BS association (named
green association) to reduce the on-grid energy consumption in HetNets supplied with hybrid (grid
and renewable) energy sources.
Given the impact of active users on the overall energy consumption, the proposal focuses
on minimizing the on-grid consumption by balancing the downlink traffic loads among BSs with
an appropriate user-BS association scheme. The reactive control scheme modifies the BS-selection
procedure by prioritizing renewable-powered BSs over a grid-powered MBS.

3.4. Best-Signal-Level Policy


Traditional cellular networks employ the best-signal-level policy, which consists of mobile users
connecting to the BS with the best SINR. Issues such as power transmission, path loss, and interference
with other BSs can influence the SINR of a base station. Conversely, the best-signal-level mechanism
(referred to as the traditional scheme) is not fully suitable for hybrid-energy HetNets because available
SCBSs can be ignored by users who receive a stronger signal from the MBS [41]. The traditional
scheme will be used as the baseline to assess the proposed coalitional MPC algorithm and other
MPC-based schemes.

4. Illustrative Examples
Controllers are assessed in the MATLAB environment. To this end, two case studies that consist
of a two-tiered downlink HetNet composed of an MBS and multiple SCBSs are considered. Mainly,
it is the impact on grid energy consumption and stored energy management that we want to analyze.

4.1. Case Studies


The following two simulated HetNets are proposed to test the proposed coalitional
MPC algorithm:

1. An academic scenario with a set of B = {1, . . . , 9} base stations (one MBS and eight SCBSs),
which is sophisticated enough to show the potential of the proposed method (see Figure 2a).
The complexity of the association process is caused by the number of BSs and active users.
2. A large scenario with a set of B = {1, . . . , 37} base stations (one MBS and 36 SCBSs), which
represents the complexity of real problems (see Figure 2b). In this case, it is only possible to
compare the proposed method with a heuristic approach.

In both cases, the MBS is fed by on-grid energy to ensure coverage over the area. On the other
hand, SCBSs are locally fed by renewable energy and equipped with storage batteries. Only path losses
between users and BSs are considered. Furthermore, user requests follow a Homogeneous Poisson
Process (HPP) with λ p = λ for simplicity.
Energies 2020, 13, 6546 10 of 19

37
2 3 31
36
25
35 30
24 19
29 13
34 23 18
28 7
5 33 17 12
4 6
27 22 1 6
32 11
1 21 16 5
26 10
20 15
9 4
14
7 3
8 8
9
2
(a) (b)

Figure 2. Simulated scenarios: (a) 9-BS network, and (b) 37-BS network. Blue lines refer fixed
communication links between the SCBSs and the MBS; and green lines refer to dynamic cooperation
links between the SCBSs.

4.2. Simulation Parameters


The implementation of user-BS association controllers is assumed to be faster than the dynamics
of user traffic. When new information is available, the calculations are updated accordingly. Moreover,
changes in renewable energy arrival and the spatial variability in the behavior of active users are
considered in a simulation of N = 50 time instants. According to [8], a summary of the simulation
parameters is displayed in Table 1. The impact of tuning parameters in coalitional control has been
explored in other references such as [29,42,43]. In this case, we keep the parameters constant so as
to focus on the difference of performance between the centralized optimization and the proposed
method, which is the main goal of the article.
Furthermore, 5G defines three general bands for the deployment of its services, named low band
(<1 GHz), mid-band (between 1 GHz and 6 GHz), and high band (<6 GHz). In this work, we consider
the scenarios in mid-band frequencies, based on the fact that these frequencies were thought to improve
simultaneously capacity and coverage.

Table 1. Summary of the main parameters.

Description Value Units


A Coverage area 3.5 km2
BW Bandwidth of the LTE system 20 MHz
di,j Inter-site distance 500 m
T1 Transmission power of the MBS 43 dBm
Ti Transmission power of the SCBSs 22 dBm
E1S Static power consumption of the MBS 130 W.h
EiS Static power consumption of the SCBSs 6.8 W.h
∆1 Consumption slope of the MBS 4.7 –
∆i Consumption slope of the SCBSs 4.0 –
Fi,j Max. users flow between the BSs 100 –
zimax Max. users served by the SCBSs 200 –
bmax
i Max. battery capacity of the SCBSs 200 W.h
Np Prediction horizon 5 –
Tup Upper layer execution 10 –
Q Weighting parameter 100 –
αi Weighting factor 107 –
clink Cost per cooperation link 104 –
- Path loss between the MBS and z Cost 231 model –
- Mobility model Random walk –
- Mobility speed 4 km/h
Energies 2020, 13, 6546 11 of 19

4.3. Disturbances
In addition to the input and output of users, base stations are affected by disturbances
such as weather, which determines renewable energy generation. The renewable energy arrival,
which determines clusters of SCBSs during specific periods, can be estimated with sensor
measurements. In this way, active BSs change according to a pre-defined sequence while users
are moving. In Figure 3, the average renewable energy arrival is represented, and Figure 4 depicts the
users’ balance for the BS #9 in both scenarios. Notice that outgoing users are also taken into account
over the simulation. The MPC controller uses this information to reduce on-grid consumption.
Av. RE arrival (W.h)

30

20

10

0
0 5 10 15 20 25 30 35 40 45 50
Time (s)
(a)
Av. RE arrival (W.h)

150

100

50

0
0 5 10 15 20 25 30 35 40 45 50
Time (s)
(b)
Figure 3. Average Renewable Energy (RE) arrival: (a) 9-BS network, and (b) 37-BS network.
60 50

40
40
30
User balance

User balance

20 20

10
0
0

-20 -10
0 10 20 30 40 50 0 10 20 30 40 50
Time (s) Time (s)
(a) (b)

Figure 4. Users forecast for BS #9 in the (a) 9-BS network, and (b) 37-BS network.

4.4. Key Performance Indicators


Furthermore, the following Key Performance Indicators (KPIs) are proposed to compare the
control schemes presented in Section 3:

• Grid consumption (kWatts-hour).


• Reduction of grid consumption (%) in comparison with the best-signal level mechanism.
• Average stored energy (Watts-hour) .
• Users served (%).
Energies 2020, 13, 6546 12 of 19

• Average transmission rate (%) in comparison with the best-signal level mechanism.
• Performance cost, which is defined as the sum of the accumulated stage cost over the simulation:

N
Jperf = l C x1z (k) .
Í Í 
(13)
k=1 C ∈B/Λ

• Cooperation cost, which is defined as the sum of the cooperation cost over the simulation:

N
Jcoop =
Í Í 
g C LΛ (k) , (14)
k=1 C ∈B/Λ

with g C LΛ (k) = clink LΛ (k), where we recall that clink ∈ R>0 is the cost per active link, and LΛ (k)


denotes the number of enabled links in topology Λ at time instant k.

4.5. Results and Discussion


In this section, the results and their interpretation are discussed for the proposed simulated
systems: the academic, and the large scenario. In particular, the results are discussed from the
perspectives of the energy management, user experience, and MPC performance.

4.5.1. Academic Scenario


On evaluating the on-grid consumption, it is shown how schemes based on MPC balance their
traffic load to reduce the use of the MBS (Figure 5b) and increase the number of users served by
the SCBSs (Figure 5a). Furthermore, Table 2 displays that centralized and coalitional MPC have,
respectively, an 86.1% and 70.9% of reduction in grid consumption with respect to the traditional
scheme. Similarly, decentralized MPC has a 41.3% reduction, being a suitable option to solve the
energy consumption problem, but with less efficiency than the centralized and coalitional schemes.
The obtained results show the efficiency of MPC-based methods to decrease grid consumption.
Regarding stored energy management, centralized MPC attains 56.6 W.h as the average stored
energy; coalitional MPC stores an average energy of 57.9 W.h; and decentralized MPC achieves
an average of 56.6 W.h. Compared to the result obtained with the traditional scheme (65.5 W.h),
an improvement close to 15% is obtained regarding the use of renewable energy. Generally, the MPC
methods have similar behavior in terms of energy management. However, the reduction of the
grid consumption and traffic load of SCBSs is better with the centralized and coalitional schemes.
Nevertheless, the coalitional strategy is more suitable for non-centralized architectures.

Cen MPC Coal MPC Dec MPC

100 180

90 160

80 140

70
120
Av. users served
Av. users served

60
100
50
80
40
60
30
40
20

10 20

0 0
0 10 20 30 40 50 0 10 20 30 40 50
Time (s) Time (s)
(a) (b)

Figure 5. Average users served for the MPC-based methods in the 9-BS network: (a) SCBSs, and (b) MBS.
Energies 2020, 13, 6546 13 of 19

Table 2. Numerical results in the 9-BS network.


Energy Management User Experience MPC Costs
Grid Consumption Grid Consumption Average Stored Users Served Transmission Jtotal =
Control Scheme Jperf Jcoop
(kW.h) Improvement (%) Energy (W.h) (%) Rate (Mbps) Jperf + Jcoop

Best-signal-level 938.1 − 65.5 95.2 4.2 − − −


Energy-aware heuristic 830.3 11.5 61.2 94.7 3.9 − − −
Centralized MPC 130 86.1 56.6 96.1 4.0 4.44 · 104 1.25 · 107 1.25 · 107
Decentralized MPC 550.7 41.3 58.5 96.5 3.8 5.34 · 106 4.00 · 106 9.34 · 106
Coalitional MPC 272.8 70.9 57.9 96.3 4.0 1.64 · 105 1.14 · 107 1.16 · 107

The MPC-based schemes are compared in Figure 6, where the evolution of the four SCBSs is
depicted. The first top row shows the number of users served by the SCBS. The second and third ones
represent, respectively, the expected users flow over the simulation and the renewable energy arrival
for the SCBSs. They are disturbances for controllers, which compute appropriate control inputs to
reduce on-grid consumption and efficiently manage the stored energy. The fourth row depicts the
energy stored in the battery. Thus, the response of the controller in periods without renewable energy
arrival can be analyzed. For example, in the time interval 0–5 s, the users served by SCBS i = 7 are
zero because there is no renewable energy arrival nor energy stored in its battery. Notice the result
consistency regarding the users served by the MBS between 0 s and 5 s, as presented in Figure 5b.

Cen MPC Coal MPC Dec MPC Cen MPC Coal MPC Dec MPC
Users served

200 150
Users served

150 100
100 50
50
0
0 0 5 10 15 20 25 30 35 40 45 50
0 5 10 15 20 25 30 35 40 45 50
Users flow

40 40
Users flow

20 20
0 0
-20 0 5 10 15 20 25 30 35 40 45 50
0 5 10 15 20 25 30 35 40 45 50
RE arrival (W.h)
RE arrival (W.h)

20
20
10
10
0
0 0 5 10 15 20 25 30 35 40 45 50
0 5 10 15 20 25 30 35 40 45 50
Battery (W.h)

100
100
Battery (W.h)

75
75
50
50 25
25 0
0 0 5 10 15 20 25 30 35 40 45 50
0 5 10 15 20 25 30 35 40 45 50 Time (s)
Time (s)

(a) SCBS #2 (b) SCBS #4

Cen MPC Coal MPC Dec MPC Cen MPC Coal MPC Dec MPC
200
Users served
Users served

100 150
75 100
50 50
25
0
0 0 5 10 15 20 25 30 35 40 45 50
0 5 10 15 20 25 30 35 40 45 50

40 40
Users flow
Users flow

20 20
0 0
-20 0 5 10 15 20 25 30 35 40 45 50
0 5 10 15 20 25 30 35 40 45 50
RE arrival (W.h)

RE arrival (W.h)

20 20
10
10
0
0 0 5 10 15 20 25 30 35 40 45 50
0 5 10 15 20 25 30 35 40 45 50
100
Battery (W.h)
Battery (W.h)

100
50
50

0 0
0 5 10 15 20 25 30 35 40 45 50 0 5 10 15 20 25 30 35 40 45 50
Time (s) Time (s)

(c) SCBS #7 (d) SCBS #8

Figure 6. Comparison of four SCBSs from the 9-BS network. In each subfigure, the first row represents
the user served by the SCBS; the second one is the user flow expected; the third row depicts the
renewable energy arrival; and the fourth one shows the energy stored in the battery.
Energies 2020, 13, 6546 14 of 19

Centralized MPC achieves the best performance at the expense of using full cooperation between
subsystems. Conversely, the coalitional MPC technique adapts the topology every Tup instants
considering changes in user traffic and weather conditions. Note that centralized MPC has 72.92%
better performance cost than coalitional MPC. Even so, the latter method presents a cost reduction of
7.2% regarding centralized MPC when cooperation costs are also considered.
The percentage of users served and the average transmission rate are the KPIs used to assess
user experience. In MPC schemes, the former KPI is higher than in the best-signal-level strategy,
as shown in Table 2. Regarding average transmission rates, MPC mechanisms have reductions close to
4% compared to the traditional scheme. In the energy-aware heuristic case, the percentage of users
served is lower than the MPC schemes because it prioritizes the energy criterion over the signal level
received. As stated previously, these results stem from the relationship between the signal level and
the user rate, being an expected outcome. However, the percentage of users served in the MPC-based
schemes remains fairly steady (96%). All this, combined with the improvements previously presented,
makes coalitional control an efficient strategy to deal with energy management in the next-generation
cellular networks.

4.5.2. Large Scenario


Numerical results for the 37-BS network are displayed in Table 3. As shown, the centralized and
coalitional MPC schemes have, respectively, a 48.3% and 27.9% of grid consumption improvement.
Moreover, both methods do the best management of stored energy with 71.1 W.h in centralized MPC
and 70.5 W.h in coalitional MPC. Hence, these methods serve more users in the SCBSs with lower
consumption of stored energy. Conversely, decentralized MPC cannot manage the user flows between
SCBSs when the stored energy is spent. Thus, the number of users served by the MBS is increased,
and higher on-grid energy is consumed than other methods.

Table 3. Numerical results in the 37-BS network.


Energy Management User Experience MPC Costs
Grid Consumption Grid Consumption Average Stored Users Served Transmission Jtotal =
Control Scheme Jperf Jcoop
(kW.h) Improvement (%) Energy (W.h) (%) Rate (Mbps) Jperf + Jcoop

Best-signal-level 252.8 − 63.5 95.3 3.3 − − −


Energy-aware heuristic 227.5 10.1 60.2 94.3 2.8 − − −
Centralized MPC 130.8 48.3 71.1 95.1 3.1 4.5 × 104 1.37 × 108 1.3705 × 108
Decentralized MPC 4732.8 −1772 70.8 95.5 2.9 3.24 × 108 1.8 × 107 3.42 × 108
Coalitional MPC 182.2 27.9 70.5 95.1 3.1 5.02 × 105 1.36 × 108 1.365 × 108

Figure 7 presents the distribution of users between base stations for the MPC schemes.
The centralized and coalitional MPC strategies have better user management over the simulation
time, while decentralized MPC can only transfer users to the MBS when the SCBSs do not have
stored energy in their batteries. Thus, decentralized MPC is not an appropriate scheme to deal with
consumption problems in NGCNs.
Additionally, Figure 8 presents the behavior of several SCBSs with different renewable energy
arrival profiles. First, it is observed how the SCBSs without renewable energy arrival use the energy
stored in their batteries to guarantee the user service. However, in the centralized and coalitional
MPC schemes, users are transferred to other BSs when there is no stored energy. When renewable
energy arrives, the batteries maintain a reserve level to serve users and balance the consumed energy
according to the arrival forecast. This behavior shows a desirable energy management scheme because
the average energy stored in batteries is a 35% of its capacity, the percentage of load in SCBSs is 55%,
and the average occupation of the MBS is 8.35%, as depicted in Figure 7.
Energies 2020, 13, 6546 15 of 19

Cen MPC Coal MPC Dec MPC


120 1400

1200
100

1000
80

Av. user served


Av. user served
800
60
600

40
400

20 200

0 0
0 10 20 30 40 50 0 10 20 30 40 50
Time (s) Time (s)
(a) (b)

Figure 7. Average users served for the MPC-based methods in the 37-BS network: (a) SCBSs, and (b) MBS.

Cen MPC Coal MPC Dec MPC Cen MPC Coal MPC Dec MPC
100 200
Users served
Users served

75 150
50 100
25 50
0
0
0 5 10 15 20 25 30 35 40 45 50 0 5 10 15 20 25 30 35 40 45 50

40
Users flow

40
Users flow

20 20
0 0

0 5 10 15 20 25 30 35 40 45 50 0 5 10 15 20 25 30 35 40 45 50
RE arrival (W.h)

RE arrival (W.h)

1 200
150
0 100
50
-1
0 5 10 15 20 25 30 35 40 45 50 0
0 5 10 15 20 25 30 35 40 45 50
100 150
Battery (W.h)

Battery (W.h)

75 125
50
100
25
75
0
0 5 10 15 20 25 30 35 40 45 50 50
Time (s) 0 5 10 15 20 25 30 35 40 45 50
Time (s)

(a) SCBS #9 (b) SCBS #18

Cen MPC Coal MPC Dec MPC Cen MPC Coal MPC Dec MPC
100 200
Users served
Users served

75 150
50 100
25 50
0 0
0 5 10 15 20 25 30 35 40 45 50 0 5 10 15 20 25 30 35 40 45 50

40 40
Users flow

Users flow

20 20
0
0

0 5 10 15 20 25 30 35 40 45 50 0 5 10 15 20 25 30 35 40 45 50
RE arrival (W.h)

RE arrival (W.h)

1 200
150
0 100
50
-1 0
0 5 10 15 20 25 30 35 40 45 50 0 5 10 15 20 25 30 35 40 45 50

150
Battery (W.h)
Battery (W.h)

100
100
50
50
0
0 0 5 10 15 20 25 30 35 40 45 50
0 5 10 15 20 25 30 35 40 45 50
Time (s)
Time (s)

(c) SCBS #27 (d) SCBS #36

Figure 8. Comparison of several SCBSs from the 37-BS network. In each subfigure, the first row
represents the user served by the SCBS; the second one is the user flow expected; the third row depicts
the renewable energy arrival; and the fourth one show the energy stored in the battery.
Energies 2020, 13, 6546 16 of 19

5. Conclusions
The broad spatial distribution of cellular networks and the exponential growth of 5G mobile
devices promote distributed control methods and alternative sources such as solar, hydro, and wind
energy. This article proposes a hierarchical coalitional MPC algorithm to dynamically manage the
user-BS association in two simulated hybrid-energy HetNets of different scales. Its assessment
regarding the best-signal-level and energy-aware heuristic methods has shown an efficient way
to hold the quality of service while reducing on-grid consumption.
Furthermore, the coalitional strategy has been compared with centralized and decentralized
MPC. As is known, centralized MPC always has the best performance at the expense of full
communication between base stations. Since the viewpoint is to find a trade-off between performance
and communication costs, coalitional MPC becomes a suitable method to adapt the network topology
dynamically. It mainly evaluates whether a communication link between two base stations contributes
to enhancing the overall performance, and otherwise, the link is disabled to save battery storage.
Finally, scalability is also achieved for large-scale cellular networks.
Open research lines from this work are a fully distributed implementation of coalitional MPC
and its application to the network resource management in 5G systems. The network resource
management approach can be studied not only from the energy efficiency perspective, but also
from the quality of service approach to accomplish the 5G characteristics. Additionally, we will explore
new linear models and stochastic formulations for the problem dynamics.

6. Materials and Methods


Simulated examples were performed using MATLAB R R2017a on Windows 10 with a PC
Intel R CoreTM i7-8700 CPU at 3.20 GHz and 16 GB RAM.

Author Contributions: Conceptualization, J.M.M., L.A.F., and E.M.; methodology, J.M.M. and E.M.; software,
J.M.M., E.M., and L.A.F.; validation, L.A.F. and E.M.; formal analysis, J.M.M.; investigation, E.M.; resources,
L.A.F.; data curation, E.M. and L.A.F.; writing, original draft preparation, L.A.F. and E.M.; writing, review and
editing, E.M., L.A.F., and J.M.M.; visualization, E.M. and L.A.F.; supervision, J.M.M.; project administration,
J.M.M.; funding acquisition, J.M.M., L.A.F., and E.M. All authors read and agreed to the published version of the
manuscript.
Funding: This work was supported by the European Union by means of H2020 (Project DENiM, with ID 958339)
and the European Research Council (Advanced Grant OCONTSOLAR, reference number 789051); the Spanish
Ministry of Science, Innovation, and Universities (FPU18/04476); the Colombian Ministry of Science, Technology
and Innovation-MINCIENCIAS (Ph.D. Scholarship 6172 and project number 65797/825 − 2018); the Spanish
Ministry of Economy (Project C3PO, with reference DPI2017-86918-R); and the Junta de Andalucía (Project
GESVIP, with reference number US-1265917).
Conflicts of Interest: The authors declare no conflict of interest.

Abbreviations
The following abbreviations are used in this manuscript:

BS Base Station
SCBS Small-cell Base Station
MBS Macro-cell Base Station
LTE Long-Term Evolution
MPC Model Predictive Control
MILP Mixed-Integer Linear Problem
NGCN Next-Generation Cellular Network
HetNet Heterogeneous Cellular Network
NHPP Non-Homogeneous Poisson Process
HPP Homogeneous Poisson Process
SINR Signal-to-Interference-plus-Noise Ratio
RAN Radio Access Network
ITU International Telecommunication Union
Energies 2020, 13, 6546 17 of 19

References
1. CISCO. Cisco Annual Internet Report (2018–2023). Available online: https://www.cisco.com/c/en/us/
solutions/collateral/executive-perspectives/annual-internet-report/white-paper-c11-741490.pdf (accessed
on 11 September 2020).
2. ITU. Recommendation ITU-T L.1380: Smart Energy Solution for Telecom Sites. Available online: https:
//www.itu.int/rec/T-REC-L.1380-201911-I/en (accessed on 01 December 2020).
3. Huo, Y.; Dong, X.; Wei, X.; Yuen, M. Enabling Multi-Functional 5G and Beyond UserEquipment: A Survey
and Tutorial. IEEE Access 2019, 7, 116975–117008. [CrossRef]
4. Lubritto, C.; Petraglia, A.; Vetromile, C.; Curcuruto, S.; Logorelli, M.; Marsico, G.; D’Onofrio, A. Energy and
environmental aspects of mobile communication systems. Energy 2011, 36, 1109–1114. [CrossRef]
5. Hasan, Z.; Boostanimehr, H.; BhargavaGhazzai, V. Green Cellular Networks: A Survey, Some Research
Issues and Challenges. IEEE Commun. Surv. Tutor. 2011, 13, 524–540. [CrossRef]
6. CELTIC-NEXT. Artificial Intelligence for Green Networks (AI4GREEN). 2020. Available online: https:
//ai4green.celfinet.com/ (accessed on 11 September 2020).
7. SCAVENGE. Sustainable Cellular Networks Harvesting Ambient Energy (SCAVENGE). 2019. Available
online: http://www.scavenge.eu/ (accessed on 11 September 2020).
8. Auer, G.; Giannini, V.; Desset, C.; Gódor, I.; Skillermark, P.; Olsson, M.; Imran, M.; Sabella, D.; Gonzalez, M.;
Blume, O.; Fehske, A. How much energy is needed to run a wireless network? IEEE Wirel. Commun. 2011,
18, 40–49. [CrossRef]
9. Fletscher, L.A.; Maestre, J.M.; Peroni, C.V. Coalitional Planning for Energy Efficiency of HetNets Powered by
Hybrid Energy Sources. IEEE Trans. Veh. Technol. 2018, 1–13. [CrossRef]
10. Suarez, L.; Nuaymi, L.; Bonnin, J. An overview and classification of research approaches in green wireless
networks. EURASIP J. Wirel. Commun. Netw. 2012, 2012, 142. [CrossRef]
11. Dhillon, H.; Li, Y.; Nuggehalli, P.; Pi, Z.; Andrews, J. Fundamentals of Heterogeneous Cellular Networks
with Energy Harvesting. IEEE Trans. Wirel. Commun. 2014, 13, 2782–2797. [CrossRef]
12. Gandotra, P.; Kumar, R.; Jain, S. Green Communication in Next Generation Cellular Networks: A Survey.
IEEE Access 2017. [CrossRef]
13. Morea, F.; Viciguerra, G.; Cucchi, D.; Valencia, C. Life cycle cost evaluation of off-grid PV-wind hybrid
power systems. In Proceedings of the 29th International Telecommunications Energy Conference, Rome,
Italy, 30 September–4 October 2007; IEEE: Piscataway, NJ, USA, 2007; pp. 439–441. [CrossRef]
14. Marsan, M.; Bucalo, G.; Di Caro, A.; Meo, M.; Zhang, Y. Towards zero grid electricity networking:
Powering BSs with renewable energy sources. In Proceedings of the 2013 IEEE International Conference on
Communications Workshops (ICC), Budapest, Hungary, 9–13 June 2013; pp. 596–601. [CrossRef]
15. Alsharif, M.; Nordin, R.; Ismail, M. Energy optimization of hybrid off-grid system for remote
telecommunication base station deployment in Malasya. EURASIP J. Wirel. Commun. Netw. 2015, 2015, 64–79.
[CrossRef]
16. Piro, G.; Miozzo, M.; Forte, G.; Baldo, N.; Grieco, L.; Boggia, G.; Dini, P. HetNets Powered by Renewable
Energy Sources: Sustainable Next-Generation Cellular Networks. Internet Comput. IEEE 2013, 17, 32–39.
[CrossRef]
17. Guruacharya, S.; Hossain, E. Self-Sustainability of Energy Harvesting Systems: Concept, Analysis,
and Design. IEEE Trans. Green Commun. Netw. 2017, 2, 175–192. [CrossRef]
18. Trabelsi, N.; Chen, S.; El-Azouzi, R.; Roullet, L.; Altman, E. User Association and Resource Allocation
Optimization in LTE Cellular Networks. IEEE Trans. Netw. Serv. Manag. 2017, 14, 429–440. [CrossRef]
19. Andrews, J.; Singh, S.; Ye, Q.; Lin, X.; Dhillon, H. An overview of load balancing in Hetnets: Old myths and
open problems. IEEE Wirel. Commun. 2014, 21, 18–25. [CrossRef]
20. Zhou, J.; Li, M.; Liu, L.; She, X.; Chen, L. Energy source aware target cell selection and coverage optimization
for power saving in cellular networks. In Proceedings of the 2010 IEEE/ACM Int’l Conference on Green
Computing and Communications & Int’l Conference on Cyber, Physical and Social Computing, Hangzhou,
China, 18–20 December 2010; pp. 1–8. [CrossRef]
Energies 2020, 13, 6546 18 of 19

21. Han, T.; Ansari, N. On Optimizing Green Energy Utilization for Cellular Networks with Hybrid Energy
Supplies. IEEE Trans. Wirel. Commun. 2013, 12, 3872–3882. [CrossRef]
22. Dantong, L.; Yue, C.; Kok, C.; Tiankui, Z.; Chengkang, P. Adaptive user association in HetNets with renewable
energy powered base stations. In Proceedings of the 21st International Conference on Telecommunications
(ICT), Lisbon, Portugal, 4–7 May 2014; pp. 93–97. [CrossRef]
23. Silva, A.; Tembine, H.; Altman, E.; Debbah, M. Optimum and Equilibrium in Assignment Problems With
Congestion: Mobile Terminals Association to Base Stations. IEEE Trans. Autom. Control 2013, 58, 2018–2031.
[CrossRef]
24. Liu, X.; Ansari, N. Dual-Battery Enabled Profit Driven User Association in Green Heterogeneous Cellular
Networks. IEEE Trans. Green Commun. Netw. 2018, 2, 1002–1011. [CrossRef]
25. Camacho, E.F.; Bordons, C. Model Predictive Control; Springer-Verlag London, UK, 2007.
26. Cea, M.; Goodwin, G.; Wigren, T. Model predictive zooming power control in future cellular systems
under coarse quantization. In Proceedings of the IEEE Vehicular Technology Conference (VTC Fall)),
Quebec City, QC, Canada, 3–6 September 2012. [CrossRef]
27. Garcia, V.; Lebedev, N.; Gorce, J.M. Model predictive control for smooth distributed power adaptation.
In Proceedings of the IEEE Wireless Communications and Networking Conference (WCNC), Paris, France,
1–4 April 2012. [CrossRef]
28. Maestre, J.M.; Negenborn, R.R. (Eds.) Distributed Model Predictive Control Made Easy; Springer:
Berlin/Heidelberg, Germany, 2014; Volume 69.
29. Fele, F.; Maestre, J.M.; Camacho, E.F. Coalitional Control: Cooperative Game Theory and Control.
IEEE Control Syst. 2017, 37, 53–69. [CrossRef]
30. Fele, F.; Debada, E.; Maestre, J.M.; Camacho, E.F. Coalitional Control for Self-Organizing Agents. IEEE Trans.
Autom. Control 2018. [CrossRef]
31. Hassan, H.; Nuaymi, L.; Pelov, A. Classification of renewable energy scenarios and objectives for cellular
networks. In Proceedings of the IEEE International Symposium on Personal, Indoor and Mobile Radio
Communications, PIMRC, London, UK, 8–11 September 2013; pp. 2967–2972. [CrossRef]
32. Fletscher, L.A.; Peroni, C.V.; Maestre, J.M. An assessment of different user–BS association policies for green
HetNets in off-grid environments. Trans. Emerg. Telecommun. Technol. 2017, 28, 1–15. [CrossRef]
33. Fletscher, L.A.; Suárez, L.A.; Grace, D.; Peroni, C.V.; Maestre, J.M. Energy-aware resource management
in heterogeneous cellular networks with hybrid energy sources. IEEE Trans. Netw. Serv. Manag. 2018,
16, 279–293. [CrossRef]
34. Masero, E.; Fletscher, L.A.; Maestre, J.M. A coalitional model predictive control approach for heterogeneous
cellular networks. In Proceedings of the IEEE European Control Conference (ECC), Saint Petersburg, Russia,
12–15 May 2020; pp. 448–453.
35. Han, T.; Ansari, N. A traffic load balancing framework for software-defined radio access networks powered
by hybrid energy sources. IEEE/ACM Trans. Netw. 2016, 24, 1038–1051. [CrossRef]
36. Kim, H.; de Veciana, G.; Yang, X.; Venkatachalam, M. Distributed α-Optimal User Association and Cell Load
Balancing in Wireless Networks. IEEE/ACM Trans. Netw. 2012, 20, 177–190. [CrossRef]
37. Lopez-Perez, D.; Guvenc, I.; Roche, G.; Kountouris, M.; Quek, T.; Zhang, J. Enhanced intercell interference
coordination challenges in heterogeneous networks. IEEE Wirel. Commun. 2011, 18, 22–30. [CrossRef]
38. Liu, D.; Chen, Y.; Chai, K.; Zhang, T.; Elkashlan, M. Two Dimensional Optimization on User Association and
Green Energy Allocation for HetNets with Hybrid Energy Sources. IEEE Trans. Commun. 2015, 63, 4111–4124.
[CrossRef]
39. Yang, H.; Geraci, G.; Quek, T. Energy-Efficient Design of MIMO Heterogeneous Networks with Wireless
Backhaul. IEEE Trans. Wirel. Commun. 2016, 15, 4914–4927. [CrossRef]
40. Johnson, D.; Garey, M. Computers and Intractability: A Guide to the Theory of NP-Completeness, 1st ed.;
Bell Telephone Laboratories, Incorporated: Murray Hill, NJ, USA, 1979.
41. Andrews, J. Seven ways that Hetnets are a cellular paradigm shift. IEEE Commun. Mag. 2013, 51, 136–144.
[CrossRef]
42. Muros, F.J.; Maestre, J.M.; Algaba, E.; Alamo, T.; Camacho, E.F. Networked control design for coalitional
schemes using game-theoretic methods. Automatica 2017, 78, 320–332. [CrossRef]
Energies 2020, 13, 6546 19 of 19

43. Maestre, J.M.; Ishii, H. A PageRank based coalitional control scheme. Int. J. Control. Autom. Syst. 2017,
15, 1983–1990. [CrossRef]

Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional
affiliations.

c 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access
article distributed under the terms and conditions of the Creative Commons Attribution
(CC BY) license (http://creativecommons.org/licenses/by/4.0/).