Lecture 6-7 Pumps and Pump Design
Lecture 6-7 Pumps and Pump Design
Lecture 6-7 Pumps and Pump Design
DESIGN
At the end of this lecture , the student must be able
to explain the following
1. The meaning of a water pumps
2. Purposes of a pump in water supply
3. Types of pumps
4. Classifications of pumps
5. Design of pump/ and pump curve
6. Common operational problems of pumps
7. Maintenances of a pump
PUMP
A Pump is a mechanical device using electricity
or fuel like diesel to increase the
pressure/energy of a liquids in order for such
liquids to flow from lower elevations to higher
elevations. The source of energy of a pump may
be electricity or fuel like diesel. It is an
electromechanical device capable of converting
electrical energy to mechanical/potential energy
of a fluid/liquids.
Purposes of a pump in water supply
projects
There are two major purposes for using a pump
1. Used to raise water from the intake /rivers to water treatment
plants (This is common in places where the water source adopted
for supply is river. In most cases, the river is always located at
lower elevations and water treatment plants is located in a
relatively far distances, higher than the source, and pump is
required to pump such raw water to treatment plant)
2. A pump may be used just to increase the pressure in the existing
distribution system. And this kind of pump is called a Booster
Pump
3. A pump may be used to pump water from the distribution to a
storage tank of an individual building. This happens in an
elevated Tanks
Purposes of a pump in water supply
projects
• Generally, the main purpose of any pumping
plant and pumping system is to lift water from
a lower to a higher level.
PUMP CLASSIFICATION AND
CHARACTERISTICS
Pump Classification
Although there are a wide range of pumps available
for numerous applications the generally fall into two
major groups. These are:
1. Rotodynamic Pumps (Centrifugal &Peripheral).
2. Positive Displacement Pumps (Rotary &
Reciprocating)
Rotodynamic Pumps
• Rotodynamic pumps are essentially rotary
machines in which energy is continuously imparted
to the pumped liquid by a rotating impeller or rotor
and consist of three types: Centrifugal, Peripheral
and Special Pumps as indicated in the diagram
below:
• Pumps can also be categorized as surface pumps
and submersible pumps.
Illustration of a rotodynamic pump
Real image of a rotodynamic
Drawing of a centrifugal pump pump
TYPES OF ROTODYNAMIC PUMPS
Rotodynamic-centrifugal
Centrifugal pump-is one of the rotodynamic pump
which uses rotational energy to lift water from one
point to another. Components of the centrifugal
pumps are;
1.Pump casing- protect the inner parts of the pump
but converts velocity to discharges
2.Impeller vanes –which rotates to generates
velocity
3.Suction pipe- to draw-off water from wet-well to
other point
How centrifugal pumps works
• The liquid enters the impeller eye and acquires
energy in the form of velocity as it passes though
the impeller passages. The velocity head is
converted into pressure head by the volute or
spiral shaped outer casing of the pump which
directs the liquid from the outer perimeter of the
impeller to the pump discharge
How centrifugal pumps works
• A well designed centrifugal pump, suitable for purpose,
should achieve around 80% efficiency with not more
than 20% losses in energy conversion, bearing friction
and hydraulic losses.
• Efficiency of the pump depends on several factors
including size and flow rate, with efficiency generally
increasing with size. However, efficiency drops from
time to time due to wear and tear as well as aging of
the pump and frequent uses or poor operations.
Common types of centrifugal pumps
1. Radial Flow Impellers.(if fluid flows radially)
2. Mixed Flow Impellers.if liquids flows in a
mixed direction
3. Axial Flow Impellers.if liquids flows in axial
direction
4. Overhung Impeller Type
Common types of centrifugal pumps
Type of centrifugal pump Definition of each Diagram
Radial Flow Impellers The liquid enters the impeller
axially and discharges radially,
in effect changing its
direction by 90o. In this case
the head developed is due to
the centrifugal force exerted
on the fluid by the impeller
Mixed Flow Impellers The liquid enters the impeller
axially and discharges in both
axial and radial directions. In
this case the head developed
is the result of a combination
of the centrifugal force and
the lift produced by the vanes
on the liquid.
Common types of centrifugal pumps
Types of centrifugal pumps Definition Diagram
Axial Flow Impellers The liquid enters and
leaves the impeller in an
axial direction. In this case
the head developed is
entirely due to the lift
produced by the vanes on
the liquid
Common types of centrifugal pumps
Radial and mixed flow impellers can be subdivided
into:
(i) Single suction – the liquid enters the impeller
from one side only.
(ii) Double suction – the liquid enters the impeller
from both sides
(iii) Axial flow impellers which are of the single
suction type. Please read the design manual for
water work in pumps-chapter 5 for more details
PARTS /COMPONENTS OF A
CENTRIFUGAL PUMPS
PARTS /COMPONENTS OF A
CENTRIFUGAL PUMPS
1.Casing
• The velocity head of water leaving the impeller is
converted into pressure head in the casing either by
means of a volute or by a set of stationary diffuser
vanes surrounding the impeller periphery
2.Shaft & Bearings
• The primary function of the shaft is to transmit the
driving torque to the impeller. With the support of the
bearings, the shaft must also locate the impeller
radially and axially within the casing.
• 3. Impeller- rotation
• 4. Piston
Submersible centrifugal pump
In this case, both the pump casing and the motor
are submerged. This is common in underground
tank or deep wells. The Power is supplied to the
motor through waterproof cables.
There major disadvantage is that the motor is out of
sight of any operator and easy to ‘forget’ until it
fails. Such failures are often the result of failure of
the motor-cable water seals and the motor can
burn-out under such circumstances
Peripheral Pumps
• In a peripheral pump, energy is imparted to the
fluid within the cells of a vane wheel impeller.
Alternatively, the cells are arranged peripherally
on the outer sides of a wheel disc. Peripheral
pumps come in various configurations, such as
overhung impeller, impeller(s), mounted between
bearings, single stage and multistage.
• Alternative names are side – channel pump and
regenerative turbine pump.
Peripheral Pumps
POSITIVE DISPLACEMENT PUMPS
• Positive displacement pumps are essentially
rotary or reciprocating machines in which energy
is periodically added by application of force to
movable boundaries of enclosed fluid containing
volumes, resulting in a direct increase in pressure.
The various types are illustrated on the diagram
blow:
Classifications of Positive displacement
pumps
Types of Positive displacement pumps
1. Reciprocating Pumps
A reciprocating pump is a class of positive-
displacement pumps that includes the piston pump, plunger
pump, and diaphragm pump moving backward and forward in
respond to water flows to increase the water energy. These
pumps may be further be classified as Piston / Plunger Type
and Mechanical Diaphragm Type
2. Rotary pumps
There are a number of different varieties of rotary pumps but
in all, the essential working element is a rotor which can take
a number of different forms, such as an impellor, vane or
screw or a combination of these.
Rotary pumps
• Such pumps differ from reciprocating pumps in
that the delivery is continuous and hence
smoother. However, internal losses are normally
somewhat higher through slip (internal leak-
back). Slip increases with increasing pressure so
rotary pumps are less suited to high pressure
• Rotary pumps are physically much larger than
centrifugal pumps for equivalent capacities and
therefore occupy greater space.
Rotary pumps
• Examples of Rotary pumps include
SINGLE ROTOR TYPES –
1. vane in rotor and piston rotor pumps
2. Screw – Progressive Cavity Pump
3. Flexible Member
MULTIPLE ROTOR TYPES
1) Gear Pump
2) Lobe Pump
3) Circumferential Piston
4) Multiple Screw
Rotary pumps
External Gear rotor pumps Vane in rotor pumps
Principle of operation of Positive
displacement Pumps
• A positive displacement pump makes a fluid move by
trapping a fixed amount of the fluid and forcing
(displacing) that trapped volume into a discharge pipe
or discharge system.
• Some positive displacement pumps use an expanding
cavity on the suction side and a decreasing cavity on
the discharge side. Liquid flows into the pump as the
cavity on the suction side expands and the liquid flows
out of the discharge as the cavity collapses. The
volume remains constant through each cycle of pump
operation
Principle of operation of Positive
displacement Pumps
• Positive Displacement pumps do not use
impellers, but rely on rotating or reciprocating
parts to directly push the liquid in an enclosed
cavity, until enough pressure is built up to move
the liquid into the discharge system. The pump
does not rely on raising the velocity of the fluid as
the centrifugal pump does by moving the liquid
through the impeller. Consequently, the fluid
velocity inside a positive displacement pump is
much lower than that of a centrifugal pump
Design of a pump for water supply
The requirements to be met by the pumping station is;
i. A discharge flow (Q in m3/hr). The flowrate of a pump
is usually expressed in terms of m3/s for larger pumps
and m3/hr for small pumps
ii. A total pressure head to be overcome by pumping
system(in m) HT=hs+hf
iii. Pump power =
iv. Net Positive Suction Head available (NPSHA) and Net
positive suction Head required (NPSHR).
v. Specific speed, NS = (N × Q1/2) / H3/4
Pumping Capacity
Criteria to be followed in determination of pump capacity .
1.The maximum pumping capacity of a pump station shall, be fixed to match with
the hourly average consumption of the scheme at the end of the design period;
based on a 24 hour operation in the case where a reliable electrical power supply
is provided.
2.For diesel engine powered pumps, the pumping capacity shall be fixed in
accordance with the stipulation above but based on a pumping period of not
more than 14 hours per day.
3.The maximum pumping capacity from a groundwater source shall be dictated
by the safe yield of the BH where electricity is available.
Example, for a population of 10,000 people, and per capital water requirements
of 120 l/c/d, and a PDF and PHF of 1.1 and 2.5 respectively, determine the
pumping capacity required for a Pumped scheme to feed such water supply.
Solution = Q= 10,000 X120 l/c/dx2.5 =3000 m3/d= 3000m3/24hrs = 125m3/hrs for
surface source or 3000 m3/14hrs= 215 m3/hr for groundwater such as BH.
A total pressure head to be overcome
by pumping system
• The term head is the elevation of a free surface of water
above or below a reference datum.
• The reference datum for a vertical flow centrifugal pump is
the inlet to the impeller
• Total pressure head on pump
• The total (dynamic) pressure head of the pump is
summation of the static head to be overcomed by a pump
and a total pressure headloss due to liquid friction in the
pipeline
• i.e HT = hts +hf+hfm, where hf is the pipeline friction head ,
hfm is the minor losses due to fittings and hts is the static
head which is the difference btn lower and upper points.
Component of the Total Dynamic
Head,HT
Component of the Total Dynamic
Head,HT
Component of the Total Dynamic
Head,HT
1 Determination of Static Head
• This is the level difference between suction reservoir
and delivery reservoir
2.Head loss due to friction in pipeline;
• Once the selection of pipe size and material is made,
the pressure head loss due to fluid friction in pipeline
can be determined is determined by using either darcy
wesbach headloss formulae of Hazen william-
equation..
3. Minor losses, is the headloss due to equivalents/pipe
fittings, may be elbow, tee, gate valves, check valves, cork
etc.
Headloss formulas for determination
of major headloss
Minor headloss
• This is the kind of headloss resulting from the
pipe fittings such as valves (gate and non-
return valves, elbow, Tee (male and female)
etc
Calculation of minor losses in pipe
fittings
Fittings Type K-Value
450-Elbow Standard (L/D =1) 0.35
Long Radius (L/D=1.5) 0.2
90° Elbow Curved Standard (R/D = 1) 0.75
Long Radius (L/D=1.5) 0.45
90° Elbow Square or 1.3
Mitred
Tee, Run Through Branch Blanked 0.4
Tee, as Elbow Entering in branch/run 1
Coupling/union 0.04
Gate valve Fully open 0.17
½ open 4.5
¼ open 24
¾ open 0.9
Calculation of minor losses in pipe
fittings
fitting type K-Value
Check/Non-Return Valve swing 2
Disk 10
Ball 70
Water meter Disk 7
Piston 15
Diaphram valve Fully open 2.3
1/2open 4.6
¼ open 21
¾ open 2.6
Globe valve, Bevel Seat Fully open 6
½ open 9.5
Globe Valve, Fully open 6
½ open 8.5
Example on Headloss calculation
System details
PUMP
EL172.9 m from MSL
SOLUTION
Hstat = 190.9 m- 172.9 m = 18.0 m+3m = 21m
Hf Calculate the friction losses for a 400 mm
diameter ductile iron pipe. Data, Pipe diameter, D=
400mm = 0.4m, H-W, C= 100,Q =12,000 m3/d =
0.139 m3/s, L= 300m, long pipe the total friction
headloss is
Friction head due to pipe