Excel Calculation
Excel Calculation
1
Pump Head mm m
Input Data for pump selection
Collecting reservoir base elevation 2118
Well head elevation 1981
Dynamic Water level 0
Recommended pump position 0
Recommended design discharge 8 0.008
Reservoir
Data of Height
pipelines:from under ground upto
reserviour
1 Riser pipe
Material: GS 110
Nominal diameter: 65 0.065
Length: pp 0
Transmission Main:
2 From BH head to Collection Reservoir
Material: Gs 110
Nominal diameter: 80 0.08
Length: 2555
From BH head to Junction Point
Material:
Nominal diameter:
Length:
From Junction to Collecting Reservoir
Material:
Nominal diameter:
Length:
CALCULATOR
1. Dynamic Head, HD 0
Head Loss Calculation from BH to Reservoir
1.1 Riser pipe and head work pipe loss
( hrp),riser pipe DN65mm,L=70m, Q = 5 l/s
Hrp = 10.7 (Q/C)1.85 x L / (D)4.87
1.2TransmissionHMainriser Head
pipe loss
Losses, head work 0
pipe loss ( hrp), DN 80, L=1000m,
headwork pipe length), Q = 5 l/s …(Assume
headwork pipe length)
Htp = 10.7 (Q/C)1.85 x L / (D)4.87
Bore Hole to Junction Point
Bore Hole to Reservoir, Hpressure pipe loss 132.698634500601
Junction Point to Reservoir
Hrp + Htp 132.698634500601
1.3 Minor Head Losses= 10%*(Hrp & Htp)
Hminor loss = 0.1*(Hrp +Htp) 13.2698634500601
Htr = (Hrp + Htp)major + Hminor loss 145.968497950661
HD 145.968497950661
2. Static Head, HS
HS = Static Head = (Geo. Head+ Dynamic
Water Level) + Reservior Height
2.1 Geo. Head 137
2.2 Dynamic Water Level 0
2.3 Reservoir Height 5
HS 142
TOTAL PUMP HEAD, HT
HT = HD + HS 287.968497950661
Take 363
C
DN(mm)/m
m
C
DN/mm/m
m
C
DN(mm)
m
Generator Capacity
3.125
140 KVA
KW
KW
KW