0% found this document useful (0 votes)
81 views

Excel Calculation

The document provides instructions for selecting a submersible pump based on input data about reservoir and well head elevations, recommended pump position and design discharge, and pipe material, diameter, and length from the bore hole to the collection reservoir. It calculates head losses and total pump head based on this input data. The calculations then determine the recommended pump capacity, power, and motor power needed as well as the necessary generator capacity.

Uploaded by

wondeambaw036
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
81 views

Excel Calculation

The document provides instructions for selecting a submersible pump based on input data about reservoir and well head elevations, recommended pump position and design discharge, and pipe material, diameter, and length from the bore hole to the collection reservoir. It calculates head losses and total pump head based on this input data. The calculations then determine the recommended pump capacity, power, and motor power needed as well as the necessary generator capacity.

Uploaded by

wondeambaw036
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 4

Submersible Pump Size Calculator

1
Pump Head mm m
Input Data for pump selection
Collecting reservoir base elevation 2118
Well head elevation 1981
Dynamic Water level 0
Recommended pump position 0
Recommended design discharge 8 0.008
Reservoir
Data of Height
pipelines:from under ground upto
reserviour
1 Riser pipe
Material: GS 110
Nominal diameter: 65 0.065
Length: pp 0
Transmission Main:
2 From BH head to Collection Reservoir
Material: Gs 110
Nominal diameter: 80 0.08
Length: 2555
From BH head to Junction Point
Material:
Nominal diameter:
Length:
From Junction to Collecting Reservoir
Material:
Nominal diameter:
Length:
CALCULATOR
1. Dynamic Head, HD 0
Head Loss Calculation from BH to Reservoir
1.1 Riser pipe and head work pipe loss
( hrp),riser pipe DN65mm,L=70m, Q = 5 l/s
Hrp = 10.7 (Q/C)1.85 x L / (D)4.87
1.2TransmissionHMainriser Head
pipe loss
Losses, head work 0
pipe loss ( hrp), DN 80, L=1000m,
headwork pipe length), Q = 5 l/s …(Assume
headwork pipe length)
Htp = 10.7 (Q/C)1.85 x L / (D)4.87
Bore Hole to Junction Point
Bore Hole to Reservoir, Hpressure pipe loss 132.698634500601
Junction Point to Reservoir
Hrp + Htp 132.698634500601
1.3 Minor Head Losses= 10%*(Hrp & Htp)
Hminor loss = 0.1*(Hrp +Htp) 13.2698634500601
Htr = (Hrp + Htp)major + Hminor loss 145.968497950661
HD 145.968497950661
2. Static Head, HS
HS = Static Head = (Geo. Head+ Dynamic
Water Level) + Reservior Height
2.1 Geo. Head 137
2.2 Dynamic Water Level 0
2.3 Reservoir Height 5
HS 142
TOTAL PUMP HEAD, HT
HT = HD + HS 287.968497950661
Take 363

Pump parameter pump capacity generator parameter


Total pump Head 2900.54464146498 2.5*power factor
pump efficiency(µ) 70% 71.4 Generator power
pump power 40.6238745303219
motor power 44.6862619833541
Take 45
Description C Value
GS 120
masl uPVC 130
masl DCI 130
m HDPE 130
m
l/s /(m3/s)
m

C
DN(mm)/m
m

C
DN/mm/m
m

C
DN(mm)
m
Generator Capacity
3.125
140 KVA
KW
KW
KW