This document provides process data for a heavy refinery slop oil storage tank including: - Nominal capacity of 23,247 cubic meters and net capacity of 20,000 cubic meters. - Dimensions of 40,000mm diameter and 18,500mm height. - Materials used for the shell, bottom, and annular plate. - Details of 44 nozzles including sizes and services.

Uploaded by

hector cano mora
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
88 views5 pages

Data Sheets

This document provides process data for a heavy refinery slop oil storage tank including: - Nominal capacity of 23,247 cubic meters and net capacity of 20,000 cubic meters. - Dimensions of 40,000mm diameter and 18,500mm height. - Materials used for the shell, bottom, and annular plate. - Details of 44 nozzles including sizes and services.

Uploaded by

hector cano mora
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

API 650 | TK ALMACENAMIENTO

API 650 | STORAGE TANKS


Curso Online | Online Course
Fondo del Tanque | Tank Bottom

Hoja de Datos | Data Sheet

Instructor: Javier Tirenti


www.arvengtraining.com
TK-03 STORAGE TANK
PROCESS DATA SHEET

REV. JOB Nº
DATE UNIT
DONE CLIENT
CHECK'D LOCATION
APPRV´D DOC. Nº
REV

REV
HEAVY REFINERY SLOP OIL TANK

1 Item Nº: Quantity:


2 Service: HEAVY REFINERY SLOP OIL TANK
3 Fluid: Heavy refinery slops N13 N14
N10 MW 1/2 N11
N15
4 Nominal capacity: 23,247 m3
3
5 Net Capacity: 20,000 m
6 Diameter (ID): 40,000 mm
7 Height: 18,500 mm N12
N21
A/B/C
8 Operating ATM kg/cm2(g) A/B/C/D
N6 N19
9 TANK PRESSURE Design ATM kg/cm2(g)
A/B/C
10 Vacuum design -0.005 kg/cm2(g) N1 A/B
N16 A/B
11 TANK Operating 95 ºC
N17 A/B
TEMPERATURE N8
12 Design 118 ºC
N5 MW A/B/C N2 A/B
13 Operating Press. 4.5 kg/cm2(g)
14 Operating Temp. 170 ºC N20 1 N3
15 Design Press. 6.4 kg/c/m2(g) N4 A/B N9
COIL (Note 7)
16 Design Temp. 240 ºC
17 Nom. Diameter 4 in N18
A/B
18 Length
Len gth 500 m
19 MATERIAL CORR. ALLOW. Liquid Levels:
HHLL 18103 mm
20 Shell / Roof KCS ASTM Ys>255 5 mm HLL 17944 mm
21 Bottom KCS ASTM Ys> 3 mm LLL 2029 mm
LLLL 2002 mm
22 Annular plate Same as shell 5 mm
23
24 Type X Dome Roof X Floating Roof Design Wind Speed: 190 Km/h -
25 API Refrigerated Short term maximum temperature: N.A. ºC kg/cm2(g)
26 Bottom Flat Short term minimun temperature: N.A. ºC kg/cm2(g)
27 Conical Pointing Downwards TANK VENTING DATA: (Note 9,15)
28 Conical Pointing Upwards - Blanketing: -
29 Code: API STD. 650 - Max inbreathing rate: - Kg/h
30 Stress Relieve for Process Reasons: - Max outbreathing rate: - Kg/h
31 Insulation: Type - - Emergency relief: Flow: Kg/h /MW: Kg/Kmol
32 Thickness - mm - Relieving: Temperature: ºC /Pressure: Kg/cm2(g)
33 NOZZLES NOZZLES
34 Nº Quantity Size Service Nº Quantity Size Service
35 N1 A/B 2 12" Liquid Inlet N12 A/B/C 3 8" Fire-fighting nozzle

36 N2 A/B 2 10" Pump suction N13 1 4" Level transmitter

37 N3 1 2" Pres transmitter N14 1 8" Gauge Hatch


38 N4 A/B 2 4" Drain MW 1/2 2 24" Roof manway/Emergency venting

39 N5 1 2" Thermowell N15 1 2" Temp multipoint instrument

40 N6 1 2" Temp transmitter N16 A/B 2 4" Steam coil - inlet line

41 N8 1 hold In-tank mixer N17 A/B 2 4" Steam coil - outlet line
42 N9 1 8" Pump suction DO N18 A/B 2 12"/4" Bottom drain
43 MW A/B/C 3 24" Manway N19A/B/C 3 8" Overflow

44 N10 1 6" Level transmitter N20 1 2" Sampling return

6" N21
45 N11 1 Open vent 4 2" Sampling
A/B/C/D
46
47

7
STORAGE TANK
PROCESS DATA SHEET

REV. JOB Nº
UNIT
DONE CLIENT
CHECK'D LOCATION
APPRV´D DOC. Nº
HEAVY REFINERY SLOP OIL TANK
REV GENERAL NOTES

1
2 1.- Minimum metal design tempeature is -18ºC
3 2.- One spare of other completed with blind flanged and gasket.
4 3.- Tank could receive: Light Coker Gasoil,Heavy Cocker Gasoil,Vacuum Residue, Heavy Vacuum Gasoil, Medium vacuum gasoil,
5 1 Light Vacuum Gasoil, Diesel, Kerosene, Unconverted oil an sour water (Wet H2S service 487ppm).
6 4.- All drain connection shall be furnished complete with the following: 4 inch nozzle, 48 inch diameter by 24 inch deep draw off sump, internal
7 piping (including downturned elbow) terminating 4 inches above bottom of sump.Two drawoff sump, set at 180º one from others.
8 5.-Nozzle near the bottom between drain nozzle and LLLL.
9 6.- Vendor shall provide accesories according to Spec last edition including clips and ring for insulation and sampling system connection.
10 1 7.- Steam-coil:lenght per coil. Low pressure steam shall be used.
11 1 8.- Deleted
12 1 9.-For normal venting and emergency venting vendor shall provide the required nozzles to comply with API-2000.(MW=242.3 Kg/Kmol, L=65.73Kcal/Kg)
13 1 (steam coil rupture :steam flowrate=21575kg/h; MW=18; Cp/Cv=1.34; Z=0.984; Tªrelieving=100ºC).
14 10.-Deleted.
15 11.- One pump
p p out nozzle,, close to suction line,, shall be furnished complete
p with drawoff sump,
p, internal piping
p p g (including
( g downturned elbow))
16 terminating one pipe diameter above the bottom of a drawoff sump and valve.Pump out nozzle shall also be connected to the suction lines
17 with external piping.
18 12.-Deleted
19 13.-Design pressure excludes static head of liquid. For product properties see Note 18. Tank shall be affected by vapor pressure changes.
20 14.-Number of Manholes and other tank's connections shall be according to Spec last eddition.
21 1 15.-It shall be determined and guarantee by tank vendor.
22 16.-Total tank's height and Nominal Capacity shall be confirmed by tank vendor.
23 17.-Tank could contain water(wet H2S service) coming from process units, interface level has to be determined.Pump suction shall be located above
24 LLLL to prevent ingress of water.
25 18.- Product properties at inlet temperature that could reach to tank are shown below:
26 Thermal
Density Vapor Press Heat capacity Viscosity
27 Product conductivity Others

28 (Kg/m3) (Kg/cm2(a)) (kcal/kgºC) (cP) (kcal/hmºC)

29 Heavy Slops 943 0.08 0.482 217 0.083 5 % wt of sulfur


30 1
31 1
32 1
33
34
35
36
37
38 1
39 1
40 1
41 1
42

43

44

8
TK-04 STORAGE TANK
PROCESS DATA SHEET

REV. JOB Nº
DATE UNIT
DONE CLIENT
CHECK'D LOCATION
APPRV´D DOC. Nº
REV

REV
CRUDE OIL TANK

1 Item Nº: Quantity:


2 Service: CRUDE OIL TANK
3 Fluid: Crude Oil (Note 3,17)
4 Nominal capacity: 73,121 m3
5 1 Net Capacity: 60,228 m3
6 Diameter (ID) : 70,000 mm
7 Height: 19,000 mm
8 Operating ATM kg/cm2(g)
9 TANK PRESSURE Design(Note 13) ATM kg/cm2(g)
10 Vacuum design - kg/cm2(g)
11 TANK Operating AMB (20ºC) ºC
12 TEMPERATURE Design 85 ºC
13 1 Operating Press. 4.5 kg/cm2(g)
14 1 Operating Temp. 170 ºC
15 Design Press. 6.4 kg/c/m2(g)
COIL (Note 7)
16 Design Temp. 240 ºC
17 1 Nom. Diameter 6 in
18 1 Length
Length 360 m Liquid levels :
19 MATERIAL CORR. ALLOW. 1 HHLL 18801 mm
20 Shell / Roof KCS ASTM Ys>245 3 mm HLL 18625 mm
21 Bottom KCS ASTM Ys>200 3 mm 1 LLL 2975 mm
22 Annular plate Same as shell 3 mm LLLL 2801 mm
23
24 Type Conical Roof Floating Roof Design Wind Speed: 190 Km/h
25 API Refrigerated Short term maximum temperature: N.A. ºC kg/cm2(g)
26 Bottom Flat Short term minimun temperature: N.A. ºC kg/cm2(g)
27 Conical Pointing Downwards TANK VENTING DATA: (Note 9,15)
28 Conical Pointing Upwards - Blanketing:
29 Code: API STD. 650 - Max inbreathing rate: Kg/h
30 Stress Relieve for Process Reasons: - Max outbreathing rate: Kg/h
31 1 Insulation: Type - - Emergency relief: Flow: Kg/h /MW: Kg/Kmol
32 1 Thickness - mm - Relieving: Temperature: ºC /Pressure: Kg/cm2(g)
33 NOZZLES NOZZLES
34 Nº Quantity Size Service Nº Quantity Size Service
35 N1 A/B 2 36" Liquid Inlet MW 1..8 8 20" Roof manway

36 N2 A/B 2 36" Pump suction 1 N12 1 2" Temp multipoint instrument

37 N4 A/B/C/D 4 4" Drain 1 N13 A..L 4 6" Steam coil - inlet line
38 1 N5 1 2" Thermowell 1 N14 A..L 4 6" Steam coil - outlet line
39 1 N6 1 3" Temp transmitter N15 VTA VTA Emergency venting
40 1 N7 1 3" Pres. transmitter N16 VTA VTA Automatic Bleeder vents
(hold) (hold)
41 1 N8 In-tank mixer N17 1 8" Gauge Hatch

N18
42 1 N9 1 24" Pump suction DO 1 4 12"/4" Bottom drain
A/B/C/D
43 MWA/B/C/D 4 24" Manway D1 1 VTA Roof drain
6"
44 1 N10 1 Level transmitter 1 N19 1 2" Sampling Return

4" N20
45 1 N11 1 Level transmitter 1 4 2" Sampling
A/B/C/D
46 See general notes of following page.

47

9
STORAGE TANK
PROCESS DATA SHEET

REV. JOB Nº
DATE UNIT
DONE CLIENT
CHECK'D LOCATION
APPRV´D DOC. Nº
CRUDE OIL TANK
REV GENERAL NOTES

1
2 1.- Minimum metal design tempeature is -18ºC
3 2.- One spare of other completed with blind flanged and gasket.
4 3.- Appart from Crude oil: Slops from Vacuum Distillation Unit(wet H2S service), Slops from Hydrogen unit,Slops from Amine Regeneration Unit,
5 Slops from Sour Water Stripper Unit,Coker Naphtha from Delay Coker Unit and Light Slops from Hydrockacking unit could reach this tank.
6 4.- All drain connection shall be furnished complete with the following: 4 inch nozzle, 48 inch diameter by 24 inch deep draw off sump, internal
7 piping (including downturned elbow) terminating 4 inches above bottom of sump.Four drawoff sump, set at 90º one from others.
8 5.-Nozzle near the bottom between drain nozzle and LLLL.
9 6.- Vendor shall provide accesories according to Spec last edition including sampling system connection.
10 1 7.- Steam-coil: lenght per coil. Low pressure steam shall be used.
11 1 8.- Deleted
12 1 9.-For normal venting and emergency venting vendor shall provide the required nozzles to comply with API-2000.(MW=80 Kg/Kmol, L=194.5Kcal/Kg)
13 1 (for steam coil rupture:steam flowrate=86300 kg/h;MW=18; Cp/Cv=1.31; Z=0.984; Tªrelieving=100ºC).
14 10.- Deleted
15 11.- One pump
p p out nozzle,, close to suction line,, shall be furnished complete
p with drawoff sump,
p, internal piping
p p g (including
( g downturned elbow))
16 terminating one pipe diameter above the bottom of a drawoff sump and valve.Pump out nozzle shall also be connected to the suction lines
17 with external piping.
18 12.-Tank shall contain water(wet H2S service) coming from slops pumps. Interface level has to be determined.
20 13.-Design pressure excludes static head of liquid. For product properties see Note 17. Tank shall be affected by vapor pressure changes.
21 14.-Number of Manholes and other tank's connection nozzles shall be according to Spec last eddition.
22 15.-It shall be determined during Detail Engineering.
23 16.-Total tank's height and Nominal Capacity shall be confirmed by tank vendor.
24 17.- Product properties at inlet temperature that could reach to tank are shown below:
25 Product Density (Kg/m3) Vapor Press (Kg/cm2(a) Others

26 Crude oil @ 29.5ºC 835 0.35 4.18%wt Sulfur

27
28
29 1
30
31
34
35 1
36 1
37 1
38 1
39 1
40
41
42
43
44
45 1
46 1
47

48