Instrumentation Question Bank
Instrumentation Question Bank
1. Quality of the Inst. Air dryer is measured with Pressure gauge Temperature Hydro meter Hygrometer Anemometer C
gauge
2. Regeneration air controller in Phase-2&3 air dryer is Direct Acting Reverse Acting Stay put Step controller B
3. IGV closed position in main air compressor means 90 Deg. 120 Deg 12 Deg. 180 Deg 60Deg C
4. Main air compressor Vibration gap voltage 10VDC 5VDC 10VAC 7.5VAC 9VDC A
5. Regeneration of Hygrometer sensor is done by Clean with Kept in dry ice High purity High purity Kept in oven C
Isopropile alcohol Nitrogen purging Hydrogen at 200 DegC
purging for 24Hrs.
6. Smart family Rosemount transmitter model is recognized as 3051 1151 3099 3144 1199 A
7. What is the DCN address of the Phase 2 ES ? FF OA O2 1 D
8. Redundancy in Phase 4 DCS (HRSG 7) is 1:1 2:1 3:1 4:1 No A
redundancy
9. In DCS DCN means Data control Distributed Dual None of these All of these C
network communication communication
network network
10. DCN rings used in CPP are redundant share the total Equally None of these All of these A
load distributed
11. In HRSG 1, when GT separation starts, MOV009 closes MOV008 closes MOV 009 closes MOV008 opens No action D
first first and MOV first and then
008 opens MOV 009
closes
12. In GT 1/2 if GT separation fails, GT will trip GT will come to GT will come to none of these No action C
FSNL spinning reserve taken
13. Power rating of solenoid valve in air dryer is 110VDC 120VDC 24VDC 220VDC 110VAC E
14. In GT 3/4/5/6, -------- no of switches are used to trip GT on 1 2 3 4 None C
high GT back pressure
15. In gas turbine for overspeed protection we have electrical mechanical both None C
16. During calibration of SRV, LVDT voltage is set at -------- 1 1.2 0.7 1.2 7 C
volts at zero position
17. GD can be opened only if GFD is open GFD is closed GT is running GT not running None B
18. GFD can be opened only if GD is open GT is running GD is open & GT GD is closed None C
not running
19. Gas turbine works on one of the thermodynamic cycle auto cycle Carnat cycle brayton cycle none All C
20. Compressor in gas turbine has _____ stages 10 15 17 14 Single stage B
21. Gas turbine is vibration measured for protection is non contact type sesmic type Both None B
22. Controller in HRSG#7 is c-controller AC460 sc-controller single loop B
controller
23. Purge permissive for coen make burners requires Both main gas main gas vent pilot gas vent Both pilot and None of the A
Page 1 of 3
Question Bank
Sr. Question Answer A Answer B Answer C Answer D Answer E Answ
No. er
vent valve and valve open ,pilot valve open , main main gas vent above
pilot gas vent gas vent valve gas vent valve valve close
valve open close close
24. For HRSG 3 TO 6 , if burner no 1 trips on flame failure All RHS burners All LHS burners All burners will Only no 1 will None of the D
will trip will trip trip trip above
25. EWLG works on principle of Inductance Capacitance Resistence Conductance Photo sensor D
26. The boiler will trip on which of the following conditions Burners trip Both scanner Both augment air Both seal air Main steam B
fan ac/dc trips fan ac/dc trips fan ac/dc trips temp goes
very high.
27. For single element control , in boiler the controlling Feed water flow Drum level Steam flow Drum temp Drum B
paramater is pressure
28. SIFT technology is implemented with AC 460 SC Controller C controller Modicon plc August PLC E
29. Pilot sensing for phase 1 burners uses IR effect UV effect Ionization effect Temp effect None C
30. For soot blower if the running PLC fails Boiler will trip Burner will trip Secondary will Soot blower will A,B,D D
take over tirp
31. If the drum pressure goes above 123kg /cm2 the boiler will True False B
trip.
32. Oxygen Measurement analyser is of which type Paramagnetic Dimagnetic Zirconia Probe Magnesium Chromatograp C
Dioxide Probe h
33. Smart transmitter sensing element is of the type Capacitance Reluctance Piezoelectric Inductance Conductance C
34. Rosemount Micromotion flowmtr can also measure Turbidity Viscosity Specific Gravity Suspended Lubricity C
Particulate
35. Which of the options will give more reliable LVDT 110 VAC 50 hz 230 VAC 50 hz 110 VDC 110 VAC , 1 230 VDC D
measurement Khz
36. Proximity probes work on which principle Capacitance Eddy Current Reluctance Static None of the B
change change generation options
37. Torque tripping in Rotork IQ type MOVs is sensed by Reduction Gears Spring loaded Motor current Motor current Magnetic Flux D
worm action only and magnetic
flux
38. In Gas Turbines ratcheting can be stopped once 300 degC 100degC 200 degC 150 degC 250 degC B
Wheelspace temperature goes below…….
39. Which Model of Rosemount make pH sensor is suitable 381PH 399PH 320HP None of the All of the C
for pH measurement of Mixed Bed Outlet in DM plants? above above
40. The MMI ( Man Machine Interface ) software in DM plant 3 Wonderware Controlview Panorama 2000 Itellusion RS view C
is -
41. The Cooling Tower 3 Data Comes to DCS through DM1 PLC DM2 PLC DM3 PLC Directly to Doesn’t C
CSS#5 of DCS comes at all
42. The Shutoff Valve of Chlorinator will close if The Chlorine The Chlorine Chlorine leakage The Power Power Water E
Page 2 of 3
Question Bank
Sr. Question Answer A Answer B Answer C Answer D Answer E Answ
No. er
Page 3 of 3