This study evaluates using nanofiltration and reverse osmosis to treat effluents from gold mining operations. Two effluents were combined and tested with different membrane types at varying pH levels and permeate recovery rates. The optimal conditions were found to be a nanofiltration membrane at pH 5.0 and a recovery rate below 40%.

Uploaded by

ecossio
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
13 views12 pages

Scielo 1

This study evaluates using nanofiltration and reverse osmosis to treat effluents from gold mining operations. Two effluents were combined and tested with different membrane types at varying pH levels and permeate recovery rates. The optimal conditions were found to be a nanofiltration membrane at pH 5.0 and a recovery rate below 40%.

Uploaded by

ecossio
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

https://doi.org/10.1590/0104-6632.

20170341s20150082

NANOFILTRATION AND REVERSE


OSMOSIS APPLIED TO GOLD MINING
EFFLUENT TREATMENT AND REUSE

Abstract
Gold mining and ore processing are activities of great economic importance. However, they are related
to generation of extremely polluted effluents containing high concentrations of heavy metals and low
pH. This study aims to evaluate the optimal conditions for gold mining effluent treatment by crossflow
membrane filtration regarding the following variables: nanofiltration (NF) and reverse osmosis (RO)
membrane types, feed pH and permeate recovery rate. It was observed that retention efficiencies of
NF90 were similar to those of RO membranes though permeate fluxes obtained were 7-fold higher.
The optimum pH value was found to be 5.0, which resulted in higher permeate flux and lower fouling
formation. At a recovery rate above 40% there was a significant decrease in permeate quality, so this
was chosen as the maximum recovery rate for the proposed system. We conclude that NF is a suitable
treatment for gold mining effluent at an estimated cost of US$ 0.83/m3.

Keywords:
Gold mining effluent treatment; Nanofiltration (NF); Reverse Osmosis (RO); Feed pH; Permeate
recovery rate

INTRODUCTION
Gold mining and ore processing are activities of great economic importance. Gold has been used in
many different applications, from raw material for jewelry manufacturing and monetary reserve to more
technological applications such as the production of catalysts and nanoparticles. On the other hand,
gold ore exploitation and processing bring forth environmental hazards that may go from natural
habitat destruction to highly polluted effluent release that may contaminate the environment (
Getaneh and Alemayehu, 2006). The effluents generated during ore processing have low pH and high
concentrations of heavy metals and metalloids such as Cd, Cr, Hg, As, etc. as these elements are
often associated with valuable components in ores and concentrates (Chan and Dudeney, 2008b;
Langsch et al., 2012).

These effluents are usually treated by neutralization, precipitation and sedimentation (


Akcil and Koldas, 2006; Correia, 2008; Langsch et al., 2012), although other technologies such as
anaerobic bioreactors (Wildeman et al., 2006), sorption (Acheampong and Lens, 2014;
Magriotis et al., 2014), coagulation and flocculation (Oncel et al., 2013; Yan et al., 2012), and
crystallization (Fernández-Torres et al., 2012) may also be used. Nevertheless, these methods may: be
insufficient to adjust effluent properties to meet discharge and/or reuse standards; require high
consumption of chemical products; and generate large volumes of metal-contaminated sludge (
Wang et al., 2007).

Membrane separation processes, specifically nanofiltration (NF) and reverse osmosis (RO), are
effective technologies to retain salts and metals from aqueous medium (Al-Rashdi et al., 2013;
Pages et al., 2013) presenting high potential to treat mining effluents for water reuse. The NF process is
an intermediate process between RO and ultrafiltration (UF) that can retain dissolved molecules with
molar mass ranging between 200 and 1,000 g/mol and multivalent ions (Yu et al., 2010). Many works
have shown that NF is an efficient system for secondary or tertiary treatment of effluents intended to
purify water for industrial, agricultural and/or indirect reuse as potable water (Acero et al., 2010a;
Acero et al., 2010b; Koyuncu et al., 2000; Shu et al., 2005). The use of NF has been increasing due to
advantages such as reliability, ease of operation, low power consumption and high efficiency (
Fu and Wang, 2011).

RO systems use membranes that are permeable to water, but substantially impermeable to salts and
therefore are suited to separate ions, dissolved metals and organic molecules of low molar mass (
Baker, 2004). One of the main applications of RO membranes is seawater desalination (
Fu and Wang, 2011). Moreover, RO membranes have increasingly become a popular water recovery
technology to treat industrial effluents (Kurt et al., 2012; Qi et al., 2011).

Sierra (2013) studied the nanofiltration process for treating an acid mine drainage from an abandoned
mercury mine. NF was able to retain up to 99% of aluminum, iron and arsenic content, and 97% of
sulfate content. Other authors (Al-Zoubi and Al-Thyabat, 2012) tested nanofiltration to treat an effluent
from a phosphate mine. Retention efficiencies between 61% and 69% for chloride, nearly 100% for
sulfate, and 83% for total solids were obtained by the NF process, ensuring a treated effluent with
quality similar to the raw water that fed the system. Chan e Dudney (Chan and Dudeney, 2008a)
evaluated the treatment of wastewater from gold ore bioleaching treated by neutralization, precipitation
and sedimentation followed by a post-treatment with RO membrane. It was found that more than 90%
of the arsenic that had not been removed by the first treatment was retained by the membrane.
Vaclav and Eva (2005) studied a RO pilot plant operation treating three different mine wastewater types,
and attained total solid retention efficiencies ranging between 88% and 98%. Another study evaluated
NF and RO membrane performance to treat two synthetic acid mine drainages, including one with
This site uses cookies to ensure you get a better browsing experience. Read our Privacy Policy. OK
higher metal content (Al-Zoubi et al., 2010). It was found that the NF membrane was more suited for
such use as it handled a higher permeate flux at lower power consumption, although its rejections
were smaller than for the RO membrane.

Despite the successful cases using different membranes for treating mining plant effluents, there
remains the need for further examination for each specific application of the most appropriate system
(NF or RO) and membrane type selection, and operational conditions such as feed pH and permeate
recovery rate. Such assessment would be targeted to find ways to increase retention efficiencies,
decrease membrane fouling formation, reduce costs and optimize the whole system. Besides that,
although the behavior of NF and RO membranes has already been extensively studied and modeled in
both single or multi-element solutions of a known compound (Childress and Elimelech, 2000;
Fujioka et al., 2012; Hoang et al., 2010; Nghiem et al., 2004; Nguyen et al., 2009; Toffoletto et al., 2010),
the operational performance of these processes to treat actual effluents cannot easily be predicted (
Krieg et al., 2005).

Therefore, this study aims to investigate the use of NF and RO for gold mining effluent treatment to
obtain water for industrial reuse. Initially, different NF and RO membranes were tested and the one
with the greatest application potential was selected. Then, tests were performed in order to define the
best operational conditions regarding feed pH and permeate recovery rate.

MATERIALS AND METHODS


Effluents from Gold Mining

Two effluents from a gold mining company in Brazil were studied, i.e., an effluent from a sulfuric acid
production plant and the water from the calcined dam. At this company, the gold ore extracted from an
underground mine undergoes processing (crushing, gravity separation and flotation), and the
concentrate is transferred to a pyrometallurgical processing unit. At this stage, it is subjected to a
roasting process by which gases containing sulfur dioxide and calcined solids are produced. At the
sulfuric acid production plant, SO2-rich gas is converted into SO3, and then it is adsorbed in an acid
solution. The effluent

from this phase, that is, the sulfuric acid production plant effluent, was the first one to be analyzed.

The calcined solids undergo a hydrometallurgical process in which the gold is leached with a sodium
cyanide solution. The solid residue is separated from the gold-rich extractant solution through a series
of thickeners with counter-current flow. Finally, the solid residue is placed in a calcined dam. The
second effluent was made up of water from this dam. The characterizations of both effluents are shown
in Table 1.

Preliminary tests showed that the performance of the membrane process was improved both in terms
of pollutant retention efficiency and membrane fouling when applied to these two effluents combined
instead of a single effluent separately. From an operational perspective, the premixed effluent also
offered the advantage of acquiring and operating a single treatment unit. Thus, both effluents were
mixed at a 1:1 ratio (corresponding to the ratio between the two actual outflow rates) before being
transferred to the membrane treatment system. In this work, such a mixture will be referred to only as
"effluent from gold mining".

The aim of the present study was to treat both of these effluents and generate reuse water to meet the
water demand in all stages of gold processing (beneficiation, hydrometallurgical and pyrometallurgical
process).

Unit description

For the nanofiltration and reverse osmosis filtration tests a bench scale unit was used. The system is
comprised of one feed tank, one pump equipped with speed controller, one valve for pressure
adjustment, one flowmeter, one manometer, one temperature gauge, and one stainless steel cell.
Figure 1 shows a schematic drawing of this unit. The stainless steel cell has a 9.8 cm diameter that
provides a filtration area of 75 cm2. The membranes tested were properly cut and placed into the cell.
A feed spacer was placed over the membrane to promote an even distribution. Permeate flux was
measured by collecting the volume of permeate in a measuring cylinder over a given period of time,
that is, 60 seconds for NF and 120 seconds for RO. The concentrate was returned to the feed tank.

Tests Conditions

The effluent from gold mining was first pretreated for each test performed. The pretreatment consisted
of ultrafiltration, which was performed using a commercial submerged membrane (ZeeWeed), PVDF-
based polymer, average pore diameter of 0.04 micrometers, with a filtration area of 0.047m2. UF
occurred at a pressure of 0.7 bar.

NF/RO filtration took place at a fixed pressure of 10 bar, feed flow rate of 2.4 LPM (corresponding to a
cross flow velocity on the surface of the membrane of 1.9 m/s and Reynolds number of 840), while the
permeate was continuously removed and the concentrate returned to the supply tank. Before every
test, all membranes were washed in two consecutive ultrasound baths for 20 minutes each, the first
containing citric acid solution at pH 2.5 and the second containing

0.1% NaOH solution. After chemical cleaning, the membrane was flushed with distilled water.

This site uses cookies to ensure you get a better browsing experience. Read our Privacy Policy. OK
Evaluation of Different NF and RO Membranes

Membrane Characteristics

The performances of five different membranes were evaluated during the treatment of the effluent from
gold mining. The RO membranes were TFC-HR and BW30, while the NF membranes were MPF34,
NF90, and NF270. The characteristics of the membranes studied, as provided by the suppliers, unless

otherwise specified, are shown in Table 2. The membranes were provided by the suppliers as flat
sheets, and were cut to properly fit into the filtration cell.

Evaluation of Membrane Performance Regarding Fouling

The NF and RO membranes were investigated regarding their fouling propensity. For this, after
membrane cleaning, they were compacted at 10 bar and water permeability was measured by
monitoring the stabilized permeate flux at pressures of 10.0, 7.5, 5.0, and 2.5 bar. Water temperature
was also monitored and the permeate flux was normalized to 25 ºC by means of a correction factor
calculated as water viscosity at 25 ºC divided by the water viscosity at the temperature of permeation (
Drak et al., 2000). With the normalized permeability, the intrinsic membrane resistance to filtration
(Rmembrane) was calculated according to Equation (1):

(1)

where K is the water permeability at 25 ºC in m3/h.m2.Pa, and µ is the viscosity of permeate (water) in
Ns/m2.

Subsequently, two liters of the pretreated effluent were fed into the NF/RO unit. Permeate flow rate and
system temperature were monitored frequently, and the flow rate results were also normalized to 25
ºC. The total and fouling resistances to filtration were calculated by Equations (2) and (3):

(2)

(3)

where P is the applied transmembrane pressure, σ is the reflection coefficient, estimated from the
averaged membrane rejection of the major constituents of the effluent (Mattaraj et al., 2008), and Δπ is
the difference in osmotic pressure of the solution in the concentrate and permeate streams. Thus, P -
σΔπ is the effective pressure, in Pa. Additionally, Jeffluent is the permeate flux in m3/h.m2.

The differences in osmotic pressure between NF/RO concentrates and permeates obtained with
different permeate recovery rates were estimated by the Equation of Van't Hoff, described in
 Equation (4):

(4)

where R is the universal gas constant, T is the permeation temperature, and ΣΔC is the sum of the
difference in molar concentrations of the main dissolved species present in the concentrate and the
permeate at a given recovery.

Intrinsic membrane resistance and fouling resistance after effluent permeation were calculated for the
five studied membranes and compared.

Evaluation of Membrane Performance Regarding Pollutant Retention

Feed and permeate samples obtained for each test were analyzed for conductivity (Hanna conductivity
meter HI 9835), total solids, arsenic concentration (atomic absorption spectrophotometer GBC 932),
sulfate and chloride (ion chromatograph Dionex ICS-1000 equipped with AS-22 and ICS 12-A
columns), in accordance with the Standard Methods for the Examination of Water and Wastewater (
APPA, 2005). The cyanide concentration was not monitored because it was low (< 0.5 mg/L in the gold
mining effluent). Membrane retention efficiencies were calculated and compared. According to the
fouling propensity and retention efficiency, the best membrane was selected for further trials.

Evaluation of pH Adjustment as a Tool for Membrane Fouling Mitigation

Process water cannot have acidic pH, so as to prevent possible wear and corrosion of equipment and
piping. Thus, for reuse of the treated effluent, its pH must be adjusted to approximately 7.0 (
Asano et al., 2007). Such adjustment can be performed before or after the membrane treatment
system. Therefore, the membrane selected with the highest potential to treat the effluent from gold
mining was tested at different pH values, namely 2.2 (original effluent pH), 3.5, 4.2, 5.0, 5.5, and 6.0.
Tests with pH above 6.0 were not performed because higher pH values did not allow better process
performance due to high membrane scaling potential, as will be shown later.

A 5.0M NaOH solution was used for the effluent pH adjustment. After adjustment, the effluent was
ultrafiltered and four liters the UF permeate was fed into the NF filtration unit. During effluent filtration
permeate flux, system temperature and accumulated permeate volume were checked every 15

minutes for 4 hours. Fouling resistance was calculated according to Equations (2) and (3).

Osmotic pressures were estimated by Equation (4) for each feed pH at each permeate recovery
rate.

This site uses cookies to ensure you get a better browsing experience. Read our Privacy Policy. OK
Raw effluent, pretreated effluent (after pH adjustment and ultrafiltration) and NF/RO permeates for
each feed pH value were analyzed for their pH, conductivity, arsenic, sulfate, chloride, calcium and
magnesium concentrations. Calcium and magnesium were analyzed by ion chromatography and the
other parameters determined as described above.

To better understand the membrane behavior at different feed pH values, the zeta potential of the
membrane was measured using a SurPASS electrokinetic analyzer supplied by Anton Paar. The zeta
potential measurement was carried out with pH values ranging from 2 to 10. The background solution
was a synthetic effluent with salt concentrations similar to the actual effluent from gold mining (
Table 3), since the actual effluent was not used because it could damage the equipment.
Permeate Recovery Rate

To establish the optimal permeate recovery rate (RR), 10 liters of effluent with pH adjusted up to the
optimum pre-determined value and then ultrafiltered were fed into the NF/RO system. The permeation
occurred with continuous permeate removal. Flux was measured for every 100 mL of permeate
obtained, while permeate conductivity and sulfate and calcium contents were analyzed for each 500
mL of permeate.

After the filtration, water flux through the fouled membrane was measured at a pressure of 10 bar. The
membrane cleanup procedure was performed using two consecutive ultrasound baths for 20 minutes
each, first with citric acid solution at pH 2.5 then with 0.1% NaOH solution. Water flux of the clean
membrane was measured at a pressure of 10 bar. These results, combined with effluent permeate flux
analyzed during the concentration experiment and initial flux through the virgin membrane were used
to calculate the flux decrease due to concentration polarization, reversible fouling and irreversible
fouling according to Capar et al. (2006).

To evaluate salt precipitation on the membrane surface, which results in scaling, the calcium sulfate
supersaturation index on the membrane surface (SIm) was determined for different RR according to
Equation (5) (Huang and Ma, 2012; Schäfer et al., 2005). Calcium sulfate was chosen as
representative of salt precipitation because it has low solubility and a high concentration in the effluent

from gold mining ( Table 1) presenting, therefore, greater precipitation potential. It is noteworthy that
in aqueous systems the hydrated specie CaSO4.2H2O is more likely to be formed; however, the
solubilities of the two salts is quite similar and therefore CaSO4 can be taken as the scaling model.

(5)

where CCa2+m and CSO42-m are the molar concentrations of Ca2+ and SO42- at the membrane/solution
interface and Ksp' is the solubility product constant for calcium sulfate based on molar concentration.

The supersaturation index is important since it can be related to the variation in Gibbs free energy (ΔG)
through Equation (6). For SIm>1, the ΔG is less than zero and the precipitation process is
thermodynamically spontaneous.

(6)

Molar concentrations at the membrane surface (Cim) were determined by


Equation (7) (
Song et al., 2013).

(7)

where Cim, Cib and Cip are the concentrations of species i at the membrane/solution interface and in
the bulk solution and permeate, respectively; Jv is the permeate flux; and ki the mass transfer constant
of species i, determined through the Sherwood number (Sh) for a radial cross-flow membrane cell (
Equations (8), (9) and (10)) (De et al., 1995).
(8)

(9)

(10)

where Re is the Reynolds number; Sc is the Schmidt number; ρ is the solution density; µ and υ are the
kinematic and dynamic viscosities, respectively; u0 is the average cross-flow velocity (
Minnikanti et al., 1999); dh the cell hydraulic diameter; Di is the diffusion coefficient of component i
(Wang et al., 2005); h is the half channel; and r is the membrane cell radius. Ksp' can be calculated
through the mass transfer constant based on activity (Ksp), as shown in Equation (11).

(e11)

where γim and aim are the activity coefficient and the activity of species i at the membrane surface. In
solutions with ionic strength lower than 0.5 M, the activity coefficients can be calculated by the Davies
This siteequation (Sawyertoetensure
uses cookies ). get a better browsing experience. Read our Privacy Policy.
al., 2003you
OK
The final permeate obtained under the best operational conditions (NF/RO membrane, feed pH and
recovery rate) was characterized for its total dissolved solids, conductivity, arsenic, sulfate, chloride,
calcium and magnesium concentrations. These results were compared with the average quality of the
process water used by the gold mining company and the industrial reuse possibility was discussed.

Economic Aspects

A preliminary investment and cost estimate of the NF/RO membrane system for treating effluent from
gold mining was conducted. The variables considered in this estimate were membrane replacement
costs, power consumption costs, system maintenance, chemical products for membrane cleanup,
alkalinizing agent for pH adjustment, personnel costs and unit depreciation.

The alkalizing agent considered for pH adjustment was NaOH. The volume of NaOH solution used to
adjust the effluent pH value was measured and used to estimate the process neutralizing cost. The
NaOH price was US$ 0.43 per kg. NF and UF membrane prices were US$ 90 and US$ 135 per square
meter, respectively. These prices were based on a preliminary estimate provided by a large
commercial membrane supplier. The required membrane area was calculated based on the total flow
rate of 280 m3/h (effluent flow rate informed by the mining company), permeate flux of 20 L/h.m2 for NF
and 100 L/h.m2 for UF (obtained in this study). Membrane lifespan was estimated as 3 years (
Van der Merwe, 1998), while depreciation time was up to 15 years. Personnel costs included payroll for
hiring four technicians/operators and 13 annual salaries plus 70% corresponding to labor costs (payroll
taxes and benefits) (Zancula, 2013). According to the membrane supplier, system maintenance charges
correspond to 5% of the initial investment. The cleaning agents cost was US$ 0.10/m3 of effluent.
Power consumption expenditure estimated by ROSA 9.1 software was 0.27 kWh/m3 and the electricity
tariff employed was US$ 0.15/kWh (CEMIG, 2014).

RESULTS AND DISCUSSION


Evaluation of Different NF and RO Membranes

The membranes used in this study are comprised of a thin selective layer of polyamide. Although the
selective layer of all five membranes is formed by the same base polymer, their complete compositions
are unknown and they are likely to be very different (Nghiem and Hawkes, 2007). Thus, membrane
properties that affect retention capacity and fouling propensity differ from one membrane to another.
Although the literature presents several studies evaluating different membranes applied to many
industrial effluents (Balannec et al., 2005; Bellona et al., 2012; Chang et al., 2014; Richards et al., 2010),
effluent composition and its specific physicochemical properties directly influence treatment
performance and the results obtained for a given system cannot be simply replicated to another. Thus,
membrane evaluation for each given application is required.

The resistance of clean RO membranes (Table 4) is much higher than that of clean NF membranes,
and this is consistent with the more closed polymeric structure of the former (Tu et al., 2011). This
makes permeate flux through RO membranes very low, about 7 to 12 times lower than the permeate
flux through NF membranes. Fouling resistance shows the trend for different membranes of
undergoing adsorption, pore blocking or solid deposition over the membrane surface in contact with
the effluent (Mattaraj et al., 2011). Thus, proneness to fouling may be related to membrane
characteristics such as pore size, hydrophobicity, and surface charge. It can be seen that RO
membranes, especially TFC-HR membranes, exhibit a prompter interaction with the effluent, and more
intense fouling. Conversely, although the MPF34 membrane had one of the lowest fouling, the NF270
membrane had the highest permeate flux, nearly 60% higher than the NF90 and MPF34 membranes.

Table 5 shows the results of pollutant retention efficiency obtained for the five membranes tested.
Initially, the high retention efficiencies of both NF and RO membranes must be highlighted. The high
sulfate concentration in the effluent from gold mining is considered to be the major hindrance to water
reuse. Sulfate can precipitate with metal cations, causing fouling in equipments and pipes. It can be
seen that the permeates obtained for all membranes had a low sulfate concentration (< 200 mg/L).

Among the parameters evaluated, the only one for which the efficiency was mediocre was arsenic
retention. However, it is important to point out that, even though this element may be very hazardous to
human health and the environment, it has no adverse effect on the industrial process. The main
objective of this treatment system is to generate industrial reuse water, which can be used in gold
processing for applications that do not involve direct contact with the operators. Therefore, because the
treated effluent will not be discharged into water bodies, the discharge standard for arsenic does not
need to be met. Moreover, arsenic is not associated with problems of corrosion or fouling and may
even act as a corrosion inhibitor for zero-valent iron (Triszcz et al., 2009). Thus, obtaining a final
permeate with an arsenic content of 230 mg/L is not critical. The continuous reuse of this effluent would
lead to an arsenic buildup in the system, and when the steady-state was reached the arsenic
concentrations of the raw effluent and treated effluent (reuse water) would be 780 and 530 mg/L,
respectively (considering the worst retention efficiency of 32%, removal efficiency independent of feed
concentrations, and full replacement of process water with the treated effluent with no new water
addition).

The reverse osmosis membrane TFC-HR showed the highest pollutant retention efficiency among the
tested membranes. According to Fujioka (Fujioka et al., 2012), TFC-HR is a low pressure RO
membrane typically applied for effluent treatment and reuse processes due to its high efficiency. On
the other hand, the second RO membrane studied (BW30) showed slightly lower pollutant retention
efficiency. These results are consistent with the findings of Balannec et al. (2005) who evaluated eight
different membranes to treat a simulated dairy plant effluent.

Among the NF membranes, NF90 showed the best results for the parameters evaluated, and was
even comparable to those obtained using the TFC-HR membrane. NF90 and RO membranes have
This sitevery
usessimilar characteristics
cookies to ensure(Krieg et al.,
you get 2005), and
a better therefore
browsing NF90 may present
experience. Read ourhighPrivacy
conductivity
Policy. OK
removal efficiency, especially for an effluent in which the major contaminants are divalent ions (sulfate,
calcium, magnesium, etc.), such as the one here studied.

According to Wang and Tang (2011), the NF270 membrane has higher water permeability, lower salt
retention efficiency, and a surface smoother than the NF90 membrane. Additionally,
Nghiem and Hawkes (2007) stated that NF270 membrane pores are larger, which may explain its lower
performance. The MPF34 membrane showed the lowest retention capacity for all the parameters
analyzed. Although the molecular weight cutoff of the MPF34 membrane is lower than that of NF270 (
 Table 2), other parameters such as surface charge and hydrophobicity may affect the ion retention
capacity in aqueous solution, and may account for the lower retention efficiency observed.
Furthermore, the pore size of NF membranes is affected by the ionic strength of the medium; therefore,
the molecular weight cutoffs of the membranes differ in the presence of different solutions (
Hong and Elimelech, 1997). By assessing different NF membranes used for sulfate retention in brine,
Bargeman et al. (2009) also observed lower retention capacity for MPF34 in comparison to NF270.

The membrane area required for an application is inversely proportional to permeate flux, and the cost
of NF or RO systems depends on the membrane area required. Therefore, even though RO systems
have shown good pollutant retention efficiency, their use proved to be cost-prohibitive for the
application studied. Although NF membranes have a slightly higher cost per m2 than RO membranes (
Nghiem, 2005), the membrane area required by RO systems in this application is significantly greater,
which makes its cost substantially higher. An alternative to avoid the increase in membrane area would
be to operate the system at higher pressure. However, to achieve the same permeate flux of NF
membranes keeping the same membrane area, the operating pressure of RO would have to be above
70 bar, which is also not feasible due to excessive power consumption. Furthermore, as can be seen in
 Table 5, NF90 retention efficiencies were similar to those of RO membranes, besides allowing for a
much higher permeate flux. As a result, the NF90 membrane was selected as it showed the highest
potential for the studied application.

Evaluation of pH Adjustment as a Tool for Membrane Fouling Mitigation

Effluent pH adjustment alters its physicochemical properties because it promotes precipitation of


metals and salts. Therefore, pH adjustment followed by precipitation can be considered a pretreatment
stage, which can be associated with a suspended solids removal process, like ultrafiltration.
Pretreatment of the effluent from gold mining by pH adjustment between pH 2.2 (the original pH) and
pH 6.0 followed by ultrafiltration was studied and the physicochemical parameters of the raw effluent

and the pretreated effluent are shown in Table 6. A pH increment prompts precipitation of ions in
solution, reducing the conductivity and also calcium and magnesium concentrations. Arsenic
concentration was also gradually reduced as the pH rose. Because arsenic solubility is high (USA, 2007
), the decrease of its concentration in solution is due more to co-precipitation with other metal
hydroxydes such as iron and aluminum (Jia et al., 2012).

The nanofiltration of the effluent from gold mining with NF90 was performed with the ultrafiltration
permeates at different pH values. The filtration was carried out for 4 hours at constant pressure and
variable flux; therefore, the maximum recovery rate (RR) obtained for each condition was different.
Figure 2 shows fouling resistance as a function of both feed pH and recovery rate.
Nanofiltration at the original effluent pH resulted in the highest fouling. Over 4 hours of filtration, an
upper limit of just 27% of recovery was achieved. From the membrane zeta potential as a function of
pH, it can be seen that, at pH 2.2, the membrane has a high positive surface charge (Figure 3),
which leads to the adsorption of sulfate and other anions on the membrane, accelerating fouling and
reducing permeate flux.

On the other hand, within the same filtration time, 70% of the feed at pH 5.0 was permeated, with the
highest productivity among the evaluated conditions. Despite the high RR achieved, which greatly
increases salt concentration in the feed solution, the fouling resistance was only 8x1012 m-1 in the 4-
hour filtration process. This feed pH allowed for the lowest fouling resistance, probably because at this
pH the membrane has a small negative charge, and therefore repels anions, which prevents fouling
formation.

Filtration at pH 4.2 also showed a good performance with fouling resistance of 1.5x1013 m-1 up to a RR
of 62%. Nanofiltration at high pH values above 5.0 allowed for a better performance than at low pH
values (highest maximum RR achieved); however, the fouling resistances were higher than at pH
values between 4.2 and 5.0. In such conditions the membrane has a negative surface charge and may
form complexes with Ca2+ and Mg2+ present in the effluent in high concentrations, which leads to an
increase in fouling formation (Childress and Elimelech, 1996). Besides, at higher pHs the solubility of
salts is reduced, which can lead to membrane fouling by precipitation. The best results at pH values
near the membrane isoelectric point are consistent with the literature (Childress and Elimelech, 2000).

Table 7 presents the NF90 permeate conductivity as a function of feed pH. It is possible to see that
pH adjustment did not compromise permeate quality, as the permeate conductivities obtained at feed
pHs of 3.5, 5.0, 5.5 and 6.0 are similar to that obtained for the nanofiltration of the effluent without pH
adjustment (2.2). The sole exception was observed for a feed pH of 4.2. It is known that NF
membranes may retain pollutants through steric hindrance and electrostatic repulsion. The first is the
most important mechanism for neutral molecule retention, and the second for ionic species retention (
Childress and Elimelech, 2000; Nguyen et al., 2009). At pH values near the isoelectric point, the
membrane surface has a near neutral charge. Under such condition, only steric hindrance will prevent
the passage of solute through the membrane, decreasing its retention efficiency, as observed.

Accordingly, a feed pH equal to 5.0 was selected as the most suited for the application studied since it
allowed simultaneously for good permeate quality and the lowest fouling formation. Furthermore, it is
worth pointing out that continuous operation at very acidic pH may damage the membrane structure
and reduce its lifespan, which is also an advantage produced by the effluent pH adjustment (
This site uses cookies to ensure you get a better browsing experience. Read our Privacy Policy. OK
Manis et al., 2003).
Permeate Recovery Rate

After membrane and feed pH selection, the permeate recovery rate (RR) was studied. The permeate
RR is one of the main design parameters of systems with membranes operating under a pressure
gradient (Greenlee et al., 2009). While microfiltration and ultrafiltration usually operate at 90-96% RR,
for NF and RO these values are substantially lower (Bi et al., 2014). Since these membranes are much
more permeable to water than to solutes, increasing the RR induces an increase in salt concentration
and osmotic pressure in the concentrate and membrane fouling formation. Thus, for a constant
operating pressure, increasing the RR leads to a reduction in permeate flux. In this study, this
decrement occurred in an almost linear manner, that is, R2 = 0.947 for a linear fit, with a reduction of
nearly 0.6 L/h.m2 for each 1% increase in the RR (Figure 4).

This decay is partly explained by the reduction in the effective pressure for permeation (ΔP-σΔπ). In
Figure 4, the pure water flux was calculated considering the membrane permeability constant and
equal to that measured at the beginning of the experiment. The pure water flux reduction is thus
attributed only to a decrease of the effective pressure. However, it can be seen that the effluent flux
decay rate is more pronounced, which indicates that fouling is also occurring.

Moreover, permeate quality remains almost constant up to a RR of 40%. From this point onwards there
is a significant increase in permeate conductivity. The conductivity retention efficiency with 5% of RR
was 93.8%; this value slowly decreased to 91.3 when the RR reached 40%. However, for RR above
45%, removal efficiency reached values lower than 83%. Using a synthetic solution of MgSO4,
Bi et al. (2014) found that the degree of concentration polarization on NF membranes increased from
~1 to 1.45, while the RR increased from 20% to 70%, which was found to cause a decrease in the
observed efficiency (pollutant concentration in the permeate in relation to pollutant concentration in the
feed solution). However, no significant change was observed in its real efficiency, that is, in the
permeate pollutant concentration compared to the concentration on the membrane surface.
Additionally, the authors stated that the concentration polarization degree should be kept below 1.2 in
actual applications to be technically and economically feasible. According to Luo and Wang (2013),
higher salt concentration increased bulk viscosity, which decreased solute back-diffusion away from
the membrane, thus inducing more concentration polarization.

Table 8 presents the percentage of permeate flux decrement during filtration due to concentration
polarization, reversible fouling formation and irreversible fouling formation. One may notice that, when
the NF90 membrane is used for filtration of effluent from gold mining with a RR of 70%, there will be a
77% decrease in permeate flux in comparison to initial water flux through a clean membrane. Of these
77%, 30% are due to concentration polarization, 15% to reversible fouling formation and 32% to
irreversible fouling formation. The high percentage attributed to concentration polarization may be
associated with the high RR reached (70%), and it may be controlled in milder operational conditions
(lower RR). The percentage of flux decrement due to reversible fouling is related to the formation of
loose precipitates over the membrane surface, or physical interaction (van der Waals interaction)
between effluent components and membrane polymeric structure. Finally, irreversible fouling is caused
by sticky precipitates that cannot be easily removed by chemical cleanup. The RR must be kept low in
order to: prevent solute supersaturation in the concentrate; reduce the adhesion risk of sticky
precipitates that may reduce membrane lifespan; and prevent loose precipitate adhesion, which would
require more frequent cleanup procedures (Nanda et al., 2010).

The supersaturation ratio of CaSO4 on the membrane surface (SIm) for different values of the RR are
presented in Table 9. As the RR increases, the salt concentration in the concentrate and the
concentration polarization process intensify, consequently increasing the SIm. The SIm increment was
higher when the RR rose from 50 to 60%, when it increased by 15%. Moreover, the SIm was higher
than 1 even for feed solution (RR = 0%). However, although precipitation may be expected when SIm
>1, a significantly higher value of the supersaturation ratio must be exceeded in order to result in
scaling, due to kinetics and metastability effects (Schäfer et al., 2005). According to
Gabelich and co-workers (2011), scaling can be prevented if SICASO4 < 2.3, which is the case for the
studied effluent at RR up to ~ 60%. It is noteworthy that the SI calculation was based on the diffusivity
coefficient of ions in dilute single-component solutions. Because ion mobility in real effluents is smaller,
the actual mass transfer coefficient can be lower, and the SIm, greater than the ones calculated.

A RR of 40% was recommended for this process because operation at higher RR favors the
development of both reversible and irreversible fouling formation. Additionally, it was observed that the
permeate flux decrement was almost constant in relation to the RR increase. However, a significant
reduction in permeate quality was observed at RR greater than 40%.

It is noteworthy that a higher water recovery may be achieved with multiple NF steps, particularly if
intermediate precipitation steps are applied. In this approach, a primary NF/RO step recovers water up
to a SIm below the threshold of membrane mineral scaling. Mineral scale precursors are subsequently
removed from the concentrate via precipitation and solid-liquid separation techniques. That lowers the
concentrate mineral scaling propensity and thereby enables additional water recovery in a secondary
NF/RO step (Gabelich et al., 2011; Rahardianto et al., 2007; Rahardianto et al., 2010)

To verify the permeate applicability for industrial reuse, the physical-chemical properties of the treated
effluent obtained with the optimal operational conditions (NF90 membrane, at feed pH 5.0 and RR of
40%) were compared with process water quality used in the gold mining company (Table 10). With
the exception of arsenic, all parameters showed high retention efficiencies and proved the
effectiveness of the proposed treatment. The permeate met water reuse quality, since its pollutants
concentration for all monitored parameters were smaller than those of process water. Arsenic was the
sole pollutant to show a higher concentration in the permeate than in process water. However, as
already discussed, this metal has no fouling and/or corrosion potential and thus does not qualify as a
critical parameter.

This site uses cookies to ensure you get a better browsing experience. Read our Privacy Policy. OK
Economic Aspects

Although effluent pH adjustment reduces fouling formation and improves membrane retention
efficiency, it represents the largest investment percentage of the proposed treatment system. However,
pH adjustment is mandatory for mining wastewater reuse, since its original pH is very low. The other
major costs observed were membrane replacement and depreciation of the initial unit investment (
Table 11). The preliminary cost per m of the mining effluent treatment was only US$ 0.83.
3

CONCLUSION
It may be concluded that:

In an effluent in which the major contaminants are bivalent ions, such as effluent from gold
mining with high concentrations of sulfate, calcium and magnesium, effluent treatment with NF
membranes was more effective than with RO membranes, because they allow permeate fluxes
7 to 12 times higher and compatible retention efficiencies. In this study, NF90 showed the best
performance.

A feed pH of 5.0 provided both greater permeate flux and higher retention efficiencies. Slightly
above the membrane isoelectric point (pH 4.3), at pH 5.0 the membrane has a small negative
charge and therefore it repels anions, which prevents fouling formation.

Permeate flux decreased linearly as the permeate recovery rate increased. Additionally, there
was a significant increase in conductivity for RR above 40%. Consequently, a RR of 40% was
selected as the ideal for this process.

The proposed treatment system, operating in optimal conditions, provided a final treated effluent
with high quality at an approximate cost of US$ 0.83/m3.

ACKNOWLEDGEMENTS
The authors thank the Coordination of Improvement of Higher Education Personnel (CAPES) for the
postgraduate scholarships provided.

REFERENCES

Acero, J. L., Benitez, F. J., Leal, A. I., Real, F. J., Teva, F., Membrane filtration technologies applied
to municipal secondary effluents for potential reuse. Journal of Hazardous Materials, 177, 390-398
(2010a).

Acero, J. L., Benitez, F. J., Teva, F., Leal, A. I., Retention of emerging micropollutants from UP water
and a municipal secondary effluent by ultrafiltration and nanofiltration. Chemical Engineering
Journal, 163, 264-272 (2010b).

Acheampong, M. A., Lens, P. N. L., Treatment of gold mining effluent in pilot fixed bed sorption
system. Hydrometallurgy, 141, 1-7 (2014).

Akcil, A., Koldas, S., Acid Mine Drainage (AMD): Causes, treatment and case studies. Journal of
Cleaner Production, 14, 1139-1145 (2006).

Al-Rashdi, B., Johnson, D., Hilal, N., Removal of heavy metal ions by nanofiltration. Desalination,
315, 2-17 (2013).

Al-Zoubi, H., Rieger, A., Steinberger, P., Pelz, W., Haseneder, R., Härtel, G., Optimization study for
treatment of acid mine drainage using membrane technology. Separation Science and Technology,
45, 2004-2016 (2010).

Al-Zoubi, H. S., Al-Thyabat, S. S., Treatment of a Jordanian phosphate mine wastewater by hybrid
dissolved air flotation and nanofiltration. Mine Water and the Environment, 31, 214-224 (2012).

APPA, A., WEF, Standard methods for the examination of water and wastewater. Report No.,
American Public Health Association, Washington DC (2005).

Asano, T., Burton, F., Leverenz, H., Tsuchihashi, R., Tchobanoglous, G., Water Reuse: Issues,
Technologies, and Applications. 1st Ed. McGraw-Hill (2007).

Baker, R. W., Membrane Technology and Applications. John Wiley & Sons, 538 p. (2004).

Balannec, B., Vourch, M., Rabiller-Baudry, M., Chaufer, B., Comparative study of different
nanofiltration and reverse osmosis membranes for dairy effluent treatment by dead-end filtration.
Separation and Purification Technology, 42, 195-200 (2005).

Bargeman, G., Steensma, M., ten Kate, A., Westerink, J., Demmer, R., Bakkenes, H., Manuhutu, C.,
Nanofiltration as energy-efficient solution for sulfate waste in vacuum salt production. Desalination,
245, 460-468 (2009).

Bellona, C., Heil, D., Yu, C., Fu, P., Drewes, J. E., The pros and cons of using nanofiltration in lieu of
reverse osmosis for indirect potable reuse applications. Separation and Purification Technology, 85,
This site uses69-76
cookies to ensure you get a better browsing experience. Read our Privacy Policy.
(2012).
OK
Bi, F., Zhao, H., Zhang, L., Ye, Q., Chen, H., Gao, C., Discussion on calculation of maximum water
recovery in nanofiltration system. Desalination, 332, 142-146 (2014).

Capar, G., Yilmaz, L., Yetis, U., Reclamation of acid dye bath wastewater: Effect of pH on
nanofiltration performance. Journal of Membrane Science, 281, 560-569 (2006).

CEMIG, Values of Rates and Services (2014).

Chan, B., Dudeney, A., Reverse osmosis removal of arsenic residues from bioleaching of refractory
gold concentrates. Minerals Engineering, 21, 272-278 (2008a).

Chan, B. K. C., Dudeney, A. W. L., Reverse osmosis removal of arsenic residues from bioleaching
of refractory gold concentrates. Minerals Engineering, 21, 272-278 (2008b).

Chang, F.-f., Liu, W.-j., Wang, X.-m., Comparison of polyamide nanofiltration and low-pressure
reverse osmosis membranes on As (III) rejection under various operational conditions. Desalination,
334, 10-16 (2014).

Childress, A. E., Elimelech, M., Effect of solution chemistry on the surface charge of polymeric
reverse osmosis and nanofiltration membranes. Journal of Membrane Science, 119, 253-268
(1996).

Childress, A. E., Elimelech, M., Relating nanofiltration membrane performance to membrane charge
(electrokinetic) characteristics. Environmental Science & Technology, 34, 3710-3716 (2000).

Correia, C. S. H., Contribuição para a análise da presença de arsénio em águas de abastecimento


e sua remoção por precipitação química (Contribution to the analysis of the presence of arsenic in
drinking water and its removal by chemical precipitation), Programa de Pós Graduação em
Engenharia do Ambiente. Universidade Nova de Lisboa, Lisboa (2008). (In Portuguese).

De, S., Bhattacharjee, S., Bhattacharya, P., Development of correlations for mass transfer
coefficient in ultrafiltration systems. Developments in Chemical Engineering and Mineral
Processing, 3, 187-206 (1995).

Drak, A., Glucina, K., Busch, M., Hasson, D., Laîne, J.-M., Semiat, R., Laboratory technique for
predicting the scaling propensity of RO feed waters. Desalination, 132, 233-242 (2000).

Fernández-Torres, M., Randall, D., Melamu, R., von Blottnitz, H., A comparative life cycle
assessment of eutectic freeze crystallisation and evaporative crystallisation for the treatment of
saline wastewater. Desalination, 306, 17-23 (2012).

Fu, F., Wang, Q., Removal of heavy metal ions from wastewaters: A review. Journal of
Environmental Management, 92, 407-418 (2011).

Fujioka, T., Nghiem, L. D., Khan, S. J., McDonald, J. A., Poussade, Y., Drewes, J. E., Effects of feed
solution characteristics on the rejection of N-nitrosamines by reverse osmosis membranes. Journal
of Membrane Science, 409, 66-74 (2012).

Gabelich, C. J., Rahardianto, A., Northrup, C. R., Yun, T. I., Cohen, Y., Process evaluation of
intermediate chemical demineralization for water recovery enhancement in production-scale
brackish water desalting. Desalination, 272, 36-45 (2011).

Gautam, A., Menkhaus, T. J., Performance evaluation and fouling analysis for reverse osmosis and
nanofiltration membranes during processing of lignocellulosic biomass hydrolysate. Journal of
Membrane Science, 451, 252-265 (2014).

Getaneh, W., Alemayehu, T., Metal contamination of the environment by placer and primary gold
mining in the Adola region of southern Ethiopia. Environmental Geology, 50, 339-352 (2006)

Greenlee, L. F., Lawler, D. F., Freeman, B. D., Marrot, B., Moulin, P., Reverse osmosis desalination:
water sources, technology, and today's challenges. Water Research, 43, 2317-2348 (2009).

Hoang, T., Stevens, G., Kentish, S., The effect of feed pH on the performance of a reverse osmosis
membrane. Desalination, 261, 99-103 (2010).

Hong, S., Elimelech, M., Chemical and physical aspects of natural organic matter (NOM) fouling of
nanofiltration membranes. Journal of Membrane Science, 132, 159-181 (1997).

Huang, Q., Ma, W., A model of estimating scaling potential in reverse osmosis and nanofiltration
systems. Desalination, 288, 40-46 (2012).

Jia, Y., Zhang, D., Pan, R., Xu, L., Demopoulos, G. P., A novel two-step coprecipitation process
using Fe(III) and Al(III) for the removal and immobilization of arsenate from acidic aqueous solution.
Water Research, 46, 500-508 (2012).

Koyuncu, I., Turan, M., Topacik, D., Ates, A., Application of low pressure nanofiltration membranes
for the recovery and reuse of dairy industry effluents. Water Science and Technology, 41, 213-221
(2000).

This site usesKrieg,


cookies to ensure
H., Modise, you get
S., Keizer, a better browsing
K., Neomagus, experience.
H., Salt rejection Read our
in nanofiltration forPrivacy Policy.
single and binary OK
salt mixtures in view of sulphate removal. Desalination, 171, 205-215 (2005).
Kurt, E., Koseoglu-Imer, D. Y., Dizge, N., Chellam, S., Koyuncu, I., Pilot-scale evaluation of
nanofiltration and reverse osmosis for process reuse of segregated textile dyewash wastewater.
Desalination, 302, 24-32 (2012).

Langsch, J. E., Costa, M., Moore, L., Morais, P., Bellezza, A., Falcão, S., New technology for
arsenic removal from mining effluents. Journal of Materials Research and Technology, 1, 178-181
(2012).

Luo, J., Wan, Y., Effects of pH and salt on nanofiltration - a critical review. Journal of Membrane
Science, 438, 18-28 (2013).

Magriotis, Z. M., Leal, P. V., de Sales, P. F., Papini, R. M., Viana, P. R., Arroyo, P. A., A comparative
study for the removal of mining wastewater by kaolinite, activated carbon and beta zeolite. Applied
Clay Science, 91, 55-62 (2014).

Manis, A., Soldenhoff, K., Jusuf, E., Lucien, F., Separation of copper from sulfuric acid by
nanofiltration. In: 5th International Membrane Science & Technology Conference (IMSTEC). Sydney,
Australia (2003).

Mattaraj, S., Jarusutthirak, C., Charoensuk, C., Jiraratananon, R., A combined pore blockage,
osmotic pressure, and cake filtration model for crossflow nanofiltration of natural organic matter and
inorganic salts. Desalination, 274, 182-191 (2011).

Mattaraj, S., Jarusutthirak, C., Jiraratananon, R., A combined osmotic pressure and cake filtration
model for crossflow nanofiltration of natural organic matter. Journal of Membrane Science, 322,
475-483 (2008).

Minnikanti, V., DasGupta, S., De, S., Prediction of mass transfer coefficient with suction for turbulent
flow in cross flow ultrafiltration. Journal of Membrane Science, 157, 227-239 (1999).

Nanda, D., Tung, K.-L., Li, Y.-L., Lin, N.-J., Chuang, C.-J., Effect of pH on membrane morphology,
fouling potential, and filtration performance of nanofiltration membrane for water softening. Journal
of Membrane Science, 349, 411-420 (2010).

Nghiem, L. D., Removal of emerging trace organic contaminants by nanofiltration and reverse
osmosis, Faculty of Engineering University of Wollongong, Wollongong, p. 213 (2005).

Nghiem, L. D., Hawkes, S., Effects of membrane fouling on the nanofiltration of pharmaceutically
active compounds (PhACs): Mechanisms and role of membrane pore size. Separation and
Purification Technology, 57, 176-184 (2007).

Nghiem, L. D., Schäfer, A. I., Elimelech, M., Removal of natural hormones by nanofiltration
membranes: measurement, modeling, and mechanisms. Environmental Science & Technology, 38,
1888-1896 (2004).

Nguyen, C. M., Bang, S., Cho, J., Kim, K.-W., Performance and mechanism of arsenic removal from
water by a nanofiltration membrane. Desalination, 245, 82-94 (2009).

Oncel, M., Muhcu, A., Demirbas, E., Kobya, M., A comparative study of chemical precipitation and
electrocoagulation for treatment of coal acid drainage wastewater. Journal of Environmental
Chemical Engineering, 1, 989-995 (2013).

Pages, N., Yaroshchuk, A., Gibert, O., Cortina, J. L., Rejection of trace ionic solutes in nanofiltration:
Influence of aqueous phase composition. Chemical Engineering Science, 104, 1107-1115 (2013).

Qi, L., Wang, X., Xu, Q., Coupling of biological methods with membrane filtration using ozone as
pre-treatment for water reuse. Desalination, 270, 264-268 (2011).

Rahardianto, A., Gao, J., Gabelich, C. J., Williams, M. D., Cohen, Y., High recovery membrane
desalting of low-salinity brackish water: Integration of accelerated precipitation softening with
membrane RO. Journal of Membrane Science, 289, 123-137 (2007).

Rahardianto, A., McCool, B. C., Cohen, Y., Accelerated desupersaturation of reverse osmosis
concentrate by chemically-enhanced seeded precipitation. Desalination, 264, 256-267 (2010).

Richards, L. A., Vuachère, M., Schäfer, A. I., Impact of pH on the removal of fluoride, nitrate and
boron by nanofiltration/reverse osmosis. Desalination, 261, 331-337 (2010).

Sawyer, C. N., McCarty, P. L., Parkin, G. F., Chemistry for Environmental Engineering and Science.
McGraw-Hill New York (2003).

Schäfer, A. I., Fane, A. G., Waite, T. D., Nanofiltration: Principles and Applications. Elsevier (2005).

Shu, L., Waite, T., Bliss, P., Fane, A., Jegatheesan, V., Nanofiltration for the possible reuse of water
and recovery of sodium chloride salt from textile effluent. Desalination, 172, 235-243 (2005).

Sierra, C., Saiz, J. R. Á., Gallego, J. L. R., Nanofiltration of acid mine drainage in an abandoned
mercury mining area. Water, Air, & Soil Pollution, 224, 1-12 (2013).
This site uses cookies to ensure you get a better browsing experience. Read our Privacy Policy. OK
Song, Y., Gao, X., Gao, C., Evaluation of scaling potential in a pilot-scale NF-SWRO integrated
seawater desalination system. Journal of Membrane Science, 443, 201-209 (2013).

Toffoletto, M., Merdaw, A., Sharif, A., Bertucco, A., Experimental approaches to feed solution
permeability in pressure-driven membrane separation processes. Journal of Membrane Science,
364, 27-33 (2010).

Tu, K. L., Nghiem, L. D., Chivas, A. R., Coupling effects of feed solution pH and ionic strength on
the rejection of boron by NF/RO membranes. Chemical Engineering Journal, 168, 700-706 (2011).

USA, Toxicological Profile for Arsenic. Report No., U.S. Department of Health and Human Services,
Atlanta (2007).

Vaclav, P., Eva, G., Desalting of acid mine drainage by reverse osmosis method - field tests. In: 9th
International Mine Water Congress. Oviedo, Spain (2005).

Van der Merwe, I., Application of nanofiltration in metal recovery. Journal of the South African
Institute of Mining and Metallurgy (South Africa), 98, 339-341 (1998).

Wang, Y.-N., Tang, C. Y., Protein fouling of nanofiltration, reverse osmosis, and ultrafiltration
membranes - the role of hydrodynamic conditions, solution chemistry, and membrane properties.
Journal of Membrane Science, 376, 275-282 (2011).

Wang, Z., Liu, G., Fan, Z., Yang, X., Wang, J., Wang, S., Experimental study on treatment of
electroplating wastewater by nanofiltration. Journal of Membrane Science, 305, 185-195 (2007).

Wildeman, T., Pinto, A., Tondo, L., Alves, L., Passive treatment of a cyanide and arsenic laden
process water at the RPM Gold Mine, Minas Gerais, Brazil. 2377Á2384. In: 7th International
Conference on Acid Rock Drainage (ICARD). St. Louis, USA (2006).

Xu, P., Drewes, J. E., Bellona, C., Amy, G., Kim, T.-U., Adam, M., Heberer, T., Rejection of emerging
organic micropollutants in nanofiltration-reverse osmosis membrane applications. Water
Environment Research, 40-48 (2005).

Yan, L., Wang, Y., Ma, H., Han, Z., Zhang, Q., Chen, Y., Feasibility of fly ash-based composite
coagulant for coal washing wastewater treatment. Journal of Hazardous Materials, 203, 221-228
(2012).

Yu, S., Liu, M., Ma, M., Qi, M., Lü, Z., Gao, C., Impacts of membrane properties on reactive dye
removal from dye/salt mixtures by asymmetric cellulose acetate and composite polyamide
nanofiltration membranes. Journal of Membrane Science, 350, 83-91 (2010).

Zancula, J. C., Manual Prático de Rotinas Trabalhistas (Practical Manual of Labor Routines). Portal
Tributário (2013). (In Portuguese).

Zulaikha, S., Lau, W., Ismail, A., Jaafar, J., Treatment of restaurant wastewater using ultrafiltration
and nanofiltration membranes. Journal of Water Process Engineering (2014).

Publication Dates
» Publication in this collection
Jan-Mar 2017

History
» Received » Reviewed
10 Feb 2015 14 Sept 2015
» Accepted
15 Sept 2015

This is an Open Access article distributed under the terms of the Creative Commons
Attribution License, which permits unrestricted use, distribution, and reproduction in any
medium, provided the original work is properly cited.

This site uses cookies to ensure you get a better browsing experience. Read our Privacy Policy. OK
Brazilian Society of Chemical
Engineering
Rua Líbero Badaró, 152 , 11. and.,
01008-903 São Paulo SP Brazil, Tel.:
+55 11 3107-8747, Fax.: +55 11 3104-
4649, Fax: +55 11 3104-4649 - São
Paulo - SP - Brazil
E-mail: [email protected]

SciELO - Scientific Electronic Library Online


Rua Dr. Diogo de Faria, 1087 – 9º andar – Vila Clementino 04037-003 São Paulo/SP - Brasil
E-mail: [email protected]

Leia a Declaração de Acesso Aberto

This site uses cookies to ensure you get a better browsing experience. Read our Privacy Policy. OK

You might also like