Project Job Ref.

SAA
Section Sheet no./rev.

Purlin 1
Calc. by Date Chk'd by Date App'd by Date

T 3/4/2022

Purlin design

Purlin spacing s = 2 m

Loading assumption

Dead Load

ME Services qDL1 = 0.05 kPa

Composite panel qDL2= 0.4 kPa

Purlin self weight qDL3= 0.1 kPa

Total dead load qDL = qDL1+qDL2+qDL3 = 0.550 kPa

Live Load

Roof live load qLL = 0.5 kPa

Wind Load

Downward wind load qWLdown=1.5 kPa

Upward wind load qWLup = 2.4 kPa

Inward design load UDLinward = (1.35*qDL+1.5*qWLdown)*s= 5.985 kN/m

Outward design load UDLupward = (0.9*qDL-1.5*qWLup)*s= -6.210 kN/m

Maximum purlin length = 5.5 m

Use EZ300-30 with 2 m purlin spacing

Inward design capacity; qRd_inward = 7.74 kN/m

upward design capacity; qRd_upward = 8.06 kN/m

Use EZ300-30 with 2 m purlin spacing


Inward design capacity; qRd_inward = 7.74 kN/m
upward design capacity; qRd_upward = 8.06 kN/m