CC Link SystemCompactTypeRemoteIOModule UserManual SH 4007 AA
CC Link SystemCompactTypeRemoteIOModule UserManual SH 4007 AA
Before using this product, please read this manual and the relevant manuals carefully and pay full
attention to safety to handle the product correctly.
The precautions given in this manual are concerned with this product. For the safety precautions of the
programmable controller system, refer to the user's manual for the CPU module used.
In this manual, the safety precautions are classified into two levels: " ! WARNING " and " ! CAUTION".
Under some circumstances, failure to observe the precautions given under " ! CAUTION" may lead to
serious consequences.
Observe the precautions of both levels because they are important for personal and system safety.
Make sure that the end users read this manual and then keep the manual in a safe place for future
reference.
[Design Precautions]
! WARNING
• In the case of a communication failure in the network, the status of the error station will be as
follows:
(1) All inputs from remote I/O stations are turned off.
(2) All outputs from remote I/O stations are turned off.
Check the communication status information and configure an interlock circuit in the sequence
program to ensure that the entire system will operate safely.
Incorrect output or malfunction due to a communication failure may result in an accident.
• Outputs may remain on or off due to a failure of a remote I/O module. Configure an external
circuit for monitoring output signals that could cause a serious accident.
! CAUTION
• Use the module in an environment that meets the general specifications in this manual.
Failure to do so may result in electric shock, fire, malfunction, or damage to or deterioration of
the product.
• Do not install the control lines or communication cables together with the main circuit lines or
power cables. Keep a distance of 100mm (3.94 inches) or more between them. Failure to do so
may result in malfunction due to noise.
A-1 A-1
[Installation Precautions]
! CAUTION
• Do not directly touch any conductive parts of the module. Doing so can cause malfunction or
failure of the module.
• Securely fix the module with a DIN rail or mounting screws. Tighten the screws within the
specified torque range. Undertightening can cause drop of the screw, short circuit or
malfunction. Overtightening can damage the screw and/or module, resulting in drop, short
circuit, or malfunction.
• Securely connect the cable connectors. Poor contact may cause malfunction.
[Wiring Precautions]
! WARNING
• Shut off the external power supply for the system in all phases before wiring.
Failure to do so may result in electric shock or cause the module to fail or malfunction.
! CAUTION
• Ground the FG terminal to the protective ground conductor dedicated to the programmable
controller. Failure to do so may result in electric shock or malfunction.
• Tighten any unused terminal screws within the specified torque range (0.42 to 0.50N•m). Failure
to do so may cause a short circuit due to contact with a solderless terminal.
• Use applicable solderless terminals and tighten them within the specified torque range. If any
spade solderless terminal is used, it may be disconnected when the terminal screw comes
loose, resulting in failure.
• Check the rated voltage and terminal layout before wiring to the module, and connect the cables
correctly. Connecting a power supply with a different voltage rating or incorrect wiring may
cause a fire or failure.
• Tighten the terminal screw within the specified torque range. Undertightening can cause short
circuit, fire, or malfunction. Overtightening can damage the screw and/ or module, resulting in
drop, short circuit, fire, or malfunction.
• When fixing the CC-Link dedicated cable and the power cable through the pipes for transmission
or power supply line of the waterproof type remote I/O module, securely tighten the nuts with a
wrench. Undertightening can cause water intrusion, resulting in failure. (AJ65SBTW -16
only.)
• Tighten the communication adapter mounting screw or the waterproof cap within the specified
torque range. Undertightening can cause short circuit, fire, or malfunction. Overtightening can
damage the screw or the cap, resulting in short circuit or malfunction. (AJ65FBTA -16 only.)
• This product meets IP67 standard under the condition that the waterproof plugs, waterproof
caps, and communication adapter are all installed. (AJ65FBTA -16 only.)
• Do not connect the cable to an incorrect connector. The I/O connector, communication
connector, and power connector have the same interface. Doing so can cause malfunction or
failure of the module. (AJ65FBTA -16 only.)
A-2 A-2
[Wiring Precautions]
! CAUTION
• Prevent foreign matter such as dust or wire chips from entering the module. Such foreign matter
can cause a fire, failure, or malfunction.
• Place the cables in a duct or clamp them. If not, dangling cable may swing or inadvertently be
pulled, resulting in damage to the module or cables or malfunction due to poor contact.
• Do not install the control lines together with the communication cables, or bring them close to
each other. Failure to do so may cause malfunctions due to noise.
• When an overcurrent caused by an error of an external device or a failure of the programmable
controller flows for a long time, it may cause smoke and fire. To prevent this, configure an
external safety circuit, such as a fuse.
• When disconnecting the cable from the module, do not pull the cable by the cable part. For the
cable with connector, hold the connector part of the cable. For the cable connected to the
terminal block, loosen the terminal screw. Pulling the cable connected to the module may result
in malfunction or damage to the module or cable.
! CAUTION
• Do not disassemble or modify the modules. Doing so may cause failure, malfunction, injury, or a
fire.
• Do not drop or apply strong shock to the module. Doing so may damage the module.
• Shut off the external power supply for the system in all phases before mounting or removing a
module. Failure to do so may cause the module to fail or malfunction.
• After the first use of the product, do not mount/remove the terminal block to/from the module
more than 50 times (IEC 61131-2 compliant).
• Before handling the module, touch a conducting object such as a grounded metal to discharge
the static electricity from the human body. Failure to do so may cause the module to fail or
malfunction.
[Disposal Precautions]
! CAUTION
• When disposing of this product, treat it as industrial waste.
A-3 A-3
• CONDITIONS OF USE FOR THE PRODUCT •
(1) Mitsubishi programmable controller ("the PRODUCT") shall be used in conditions;
i) where any problem, fault or failure occurring in the PRODUCT, if any, shall not lead to any major or
serious accident; and
ii) where the backup and fail-safe function are systematically or automatically provided outside of the
PRODUCT for the case of any problem, fault or failure occurring in the PRODUCT.
(2) The PRODUCT has been designed and manufactured for the purpose of being used in general
industries.
MITSUBISHI SHALL HAVE NO RESPONSIBILITY OR LIABILITY (INCLUDING, BUT NOT LIMITED
TO ANY AND ALL RESPONSIBILITY OR LIABILITY BASED ON CONTRACT, WARRANTY, TORT,
PRODUCT LIABILITY) FOR ANY INJURY OR DEATH TO PERSONS OR LOSS OR DAMAGE TO
PROPERTY CAUSED BY the PRODUCT THAT ARE OPERATED OR USED IN APPLICATION NOT
INTENDED OR EXCLUDED BY INSTRUCTIONS, PRECAUTIONS, OR WARNING CONTAINED IN
MITSUBISHI'S USER, INSTRUCTION AND/OR SAFETY MANUALS, TECHNICAL BULLETINS AND
GUIDELINES FOR the PRODUCT.
("Prohibited Application")
Prohibited Applications include, but not limited to, the use of the PRODUCT in;
y Nuclear Power Plants and any other power plants operated by Power companies, and/or any other
cases in which the public could be affected if any problem or fault occurs in the PRODUCT.
y Railway companies or Public service purposes, and/or any other cases in which establishment of a
special quality assurance system is required by the Purchaser or End User.
y Aircraft or Aerospace, Medical applications, Train equipment, transport equipment such as Elevator
and Escalator, Incineration and Fuel devices, Vehicles, Manned transportation, Equipment for
Recreation and Amusement, and Safety devices, handling of Nuclear or Hazardous Materials or
Chemicals, Mining and Drilling, and/or other applications where there is a significant risk of injury to
the public or property.
Notwithstanding the above, restrictions Mitsubishi may in its sole discretion, authorize use of the
PRODUCT in one or more of the Prohibited Applications, provided that the usage of the PRODUCT is
limited only for the specific applications agreed to by Mitsubishi and provided further that no special
quality assurance or fail-safe, redundant or other safety features which exceed the general
specifications of the PRODUCTs are required. For details, please contact the Mitsubishi
representative in your region.
A-4 A-4
REVISIONS
* The manual number is given on the bottom left of the back cover.
Print Date * Manual Number Revision
June 1998 SH(NA)-4007-A First printing
Nov. 1998 SH(NA)-4007-B Additional model
AJ65SBTB1-8D, AJ65SBTC4-16D, AJ65SBTW4-16D, AJ65SBTB1-8T,
AJ65SBTC4-16DT, AJ65SBTW4-16DT
Addition
Section 7.3, 7.4
Correction
Section 1.1, 1.2, 1.4, Chapter 2, 4, 5, 6, Section 7.1, Appendix 1
Apr. 1999 SH(NA)-4007-C Addition
Contents, Section 8.2.2
June 1999 SH(NA)-4007-D Additional model
AJ65SBTB1-32T1, AJ65SBTCF1-32D, AJ65SBTCF1-32T,
AJ65SBTCF1-32DT
Nov. 1999 SH(NA)-4007-E Addition
Section 1.4, 4.1.6, 4.1.7, 4.4, 5.1.8, 5.1.9, 5.1.10, 5.1.11, 5.3, 6.1, 6.4, 7.4,
Appendix 1.6, 1.7, 1.8
Correction
Section 1.1, 1.2, 1.3, 1.5, 1.6, Chapter 2, Chapter 3, Section 4.2.1, 4.3.1,
6.2.1, 6.3.1, Section 7.1, 7.4, 8.2.1, Appendix 1
Additional model
AJ65SBTB1-32DT, AJ65SBTCF1-32D, AJ65SBTCF1-32T,
AJ65SBTCF1-32DT, AJ65SBTB2-8A, AJ65SBTB2-16A, AJ65SBTB2-8R,
AJ65SBTB2-16R, AJ65SBTB2-8S, AJ65SBTB2-16S
Dec. 1999 SH(NA)-4007-F Addition
Section 1.2, 4.1.6, 4.1.7, 5.1.8, 5.1.9, 5.1.10, 5.1.11
Mar. 2000 SH(NA)-4007-G Additional model
AJ65SBTB2N-8A, AJ65SBTB2N-16A, AJ65SBTB3-8D, AJ65SBTB3-16D,
AJ65SBTB2-8T, AJ65SBTB2-16T, AJ65SBTB2N-8R, AJ65SBTB-16R,
AJ65SBTB2N-8S, AJ65SBTB2N-16S, AJ65SBTB32-8DT,
AJ65SBTB32-16DT, AJ65SBTB1-16DT, AJ65SBTB1-16DT1,
AJ65SBTB1-32DT1
Addition
Section 4.1.8, 4.1.9, 4.1.10, 4.1.11, Section 5.1.12, 5.1.13, 5.1.14, 5.1.15,
5.1.16, 5.1.17, Section 6.1.1, 6.1.3, 6.1.4, 6.1.5, 6.1.6, Appendix 1.9, 1.10
Oct. 2000 SH(NA)-4007-H Additional model
AJ65VBTCU3-8D1, AJ65VBTCU3-16D1, AJ65VBTCU2-8T,
AJ65VBTCU2-16T, AJ65VBTCF1-32DT1
Addition
Section 4.5, 5.4, 6.5, 7.2.3, 7.2.4, Appendix 1.13
Correction
Section 1.1, 1.4, 1.5, Chapter 2, Section 4.3.1, 7.1
Deletion
AJ65SBTB2-8A, AJ65SBTB2-16A, AJ65SBTB2-8R, AJ65SBTB2-16R,
AJ65SBTB2-8S, AJ65SBTB2-16S
A-5 A-5
Print Date * Manual Number Revision
Jan. 2001 SH(NA)-4007-I Additional model
AJ65FBTA4-16D, AJ65FBTA4-16DE, AJ65FBTA42-16DT,
AJ65FBTA42-16DTE
Addition
Section 1.6, 7.4, Appendix 1.14
Correction
Section 1.2, 1.4, 1.5, Chapter 2,3, Section 4.5.2, 5.3.1, 5.4.1, 5.4.2, 6.5.1,
7.1, Appendix 1.13
Jul. 2001 SH(NA)-4007-J Additional model
AJ65FBTA2-16T, AJ65FBTA2-16TE
Correction
Section 1.2, 1.4, 1.5, 4.1.6, 4.1.7, 4.2.1, 4.2.2, 4.3.1, 6.2.1, 6.2.2, 6.3.1,
6.5.1, 6.6.1, 6.6.2, 7.2.3, Appendix 1.14
Sep. 2001 SH(NA)-4007-K Additional model
AJ65SBTB1-16DT2, AJ65SBTB1-32DT2
Correction
Section 1.4, 6.1.1, 8.2.1, Appendix 1.13
Jan. 2002 SH(NA)-4007-L Additional model
AJ65SBTB1-8T1, AJ65SBTB2-8T1, AJ65SBTB2-16T1, AJ65SBTC1-32T1,
AJ65SBTB1-16DT3, AJ65SBTB1-32DT3, AJ65SBTB32-8DT2,
AJ65SBTB32-16DT2, AJ65SBTC4-16DT2, AJ65SBTC1-32DT2,
AJ65SBTC1-32DT3
Correction
Section 1.3, 1.4, 1.5, 5.5.2, 6.1.1, 7.7, 8.2.1, Appendix 1.13
Changed item numbers
Section 5.1.4 to Section 5.1.9 Section 5.1.5 to Section 5.1.10
Section 5.1.10 to Section 5.1.13 Section 5.1.13 to Section 5.1.16
Section 6.1.5 to Section 6.1.6 Section 6.1.9 to Section 6.1.10
Section 6.2.2 to Section 6.2.3 Section 6.2.3 to Section 6.2.4
Dec. 2002 SH(NA)-4007-M Correction
Section 2, Section 4 to Section 6, Section 8.2.1
May 2003 SH(NA)-4007-N Correction
Section 1.3, 1.6
Jun. 2004 SH(NA)-4007-O Additional model
AJ65VBTS3-16D, AJ65VBTS3-32D, AJ65VBTS2-16T, AJ65VBTS2-32T,
AJ65VBTS32-16DT, AJ65VBTS32-32DT, AJ65VBTCE3-8D,
AJ65VBTCE3-16D, AJ65VBTCE2-8T, AJ65VBTCE2-16T,
AJ65VBTCE32-16DT
Addition
Section 1.6.1 to 1.6.3, 4.5.3 to 4.5.5, 5.4.3 to 5.4.5, 6.5.2 to 6.5.4, 7.8, 7.9
Appendix 1.15, 1.16
Correction
Chapter 1, 2, Section 4.4.1, 4.5, 5.1, 5.4, 6.1, 6.5, 6.2.2, 6.4.1, 6.5.1, 7.2 to
7.4
Oct. 2004 SH(NA)-4007-P Correction
Section 1.1, 1.3 to 1.5, Chapter 2, 3, 4 to 6, Section 7.1, 7.4.2, 7.6, 7.7,
7.9.2, APPENDIX
A-6 A-6
Print Date * Manual Number Revision
May 2005 SH(NA)-4007-Q Additional model
AJ65VBTCE3-32D, AJ65SBTC4-16DN, AJ65SBTC4-16DE,
AJ65VBTCE32-32DT
Addition
Section 4.3.3, 4.4.3, 4.4.4, 6.3.2
Correction
SAFETY PRECAUTION, About Manuals, Compliance with the EMC and
Low Voltage Directives, Section 1.1, 1.2, 1.4, 1.5, Chapter 2,
Chapter 4 to 6, Section 7.1, 7.5, 7.7, 7.8.2, 7.9.2, Appendix 1.1, 1.2, 1.4,
1.5 to 1.10, 1.14
Changed item numbers
The order of section numbers has been changed in Chapters 4 through 6
Sep. 2005 SH(NA)-4007-R Correction
Chapter 4, through 6 have been changed for the external connection
diagrams
Sep. 2006 SH(NA)-4007-S Additional model
AJ65SBTB1B-16TE1, AJ65SBTB1-32TE1, AJ65SBTB1-32DTE1
Addition
Section 5.1.13, 5.1.14, 6.1.13
Correction
SAFETY PRECAUTION, Section 1.2, 1.4, Chapter 2, Section 7.1, 8.2.1,
8.2.2, Appendix 1.8
F.G symbol is generally revised.
Changed item numbers
Section 5.1.13 → Section 5.1.15
Section 5.1.14 → Section 5.1.16
Section 5.1.15 → Section 5.1.17
Section 5.1.16 → Section 5.1.18
Jan. 2007 SH(NA)-4007-T Additional model
AJ65SBTB3-16D5, AJ65SBTB1-32D5
Addition
Section 4.1.8, 4.1.11
Correction
Section 1.2, 1.4, Chapter 2, Section 5.1.17, 5.1.18, 8.2.2
Chapter 4 to 6 have been changed for specifications and external
connection diagrams.
Changed item numbers
Section 4.1.8 → Section 4.1.9
Section 4.1.9 → Section 4.1.10
A-7 A-7
Print Date * Manual Number Revision
Mar. 2007 SH(NA)-4007-U Additional model
AJ65DBTB1-32D, AJ65DBTB1-32T1, AJ65DBTB1-32R, AJ65DBTB1-
32DT1, AJ65DBTB1-32DR
Addition
Section 4.1.12, 5.1.19, 5.1.20, 6.1.14, 6.1.15, 7.10, 7.10.1, 7.10.2, 7.10.3,
7.10.4, 7.11, Appendix 1.15
Correction
Section 1.2, 1.3, 1.4, 1.5, Chapter 2, Section 4.3.1, 5.1.17, 5.1.18, 6.4.1,
6.4.2, 6.6.1, 6.6.2, 7.1
Sep. 2007 SH(NA)-4007-V Additional model
AJ65SBTB32-16DR, AJ65SBTB3-16KD, AJ65SBTB1-32KD,
AJ65SBTB32-16KDT2, AJ65SBTB32-16KDT8, AJ65SBTB1-32KDT2,
AJ65SBTB1-32KDT8
Addition
Section 4.1.8, 4.1.11, 6.1.9, 6.1.10, 6.1.11, 6.1.15, 6.1.17, Appendix 1.16
Correction
Section 1.2, 1.3, 1.4, Chapter 2, Section 6.6.3, 7.1
Changed item numbers
Section 4.1.8 → Section 4.1.9
Section 4.1.9 → Section 4.1.10
Section 4.1.10 → Section 4.1.12
Section 4.1.11 → Section 4.1.13
Section 4.1.12 → Section 4.1.14
Section 6.1.9 → Section 6.1.12
Section 6.1.10 → Section 6.1.13
Section 6.1.11 → Section 6.1.14
Section 6.1.12 → Section 6.1.16
Section 6.1.13 → Section 6.1.18
Section 6.1.14 → Section 6.1.19
Section 6.1.15 → Section 6.1.20
Oct. 2007 SH(NA)-4007-W Additional model
AJ65SBTB32-16KDR
Addition
Section 6.1.12
Correction
Section 1.2, 1.4, Chapter 2
Changed item numbers
Section 6.1.12 → Section 6.1.13
Section 6.1.13 → Section 6.1.14
Section 6.1.14 → Section 6.1.15
Section 6.1.15 → Section 6.1.16
Section 6.1.16 → Section 6.1.17
Section 6.1.17 → Section 6.1.18
Section 6.1.19 → Section 6.1.20
Section 6.1.20 → Section 6.1.21
A-8 A-8
Print Date * Manual Number Revision
Oct. 2008 SH(NA)-4007-X Additional model
AJ65VBTCFJ1-32DT1
Addition
Section 1.3.1, 1.3.2, 1.3.3, 1.3.4, 1.3.5, 4.4.1, 4.4.5, 5.2.1, 5.2.2, 5.3.1,
5.3.1, 6.5.3
Correction
Section 1.3
Jan. 2010 SH(NA)-4007-Y This manual was revised in accordance with IEC 60617.
Additional model
AJ65VBTCE3-16DE, AJ65VBTCE3-32DE
Addition
SAFETY PRECAUTION, Section 1.3.1, 1.4, 1.6.2, 1.7, 4.3.2, 4.3.3, 7.1,
7.2.3, 7.2.4, 7.5, 7.7
Correction
CONDITIONS OF USE FOR THE PRODUCT, Section 4.3.4, 4.3.5
Mar. 2011 SH(NA)-4007-Z This manual was revised in accordance.
Dec. 2011 SH(NA)-4007-AA Additional model
AJ65VBTCE3-16TE, AJ65VBTCE3-16DTE, AJ65VBTCE3-32DTE
Addition
Section 5.3.3, 6.3.2, 6.3.4
Correction
Chapter 3, Section 1.3.1 to 1.3.3, 1.4, 1.5, 4.6.3, 5.1.19, 6.1.1, 6.1.2,
6.1.7 to 6.1.12, 6.1.20, 6.2.1, 6.2.2, 6.3.1, 6.3.3, 6.4.1, 6.4.2, 6.6.1 to 6.6.3,
7.1, 7.2.2, 7.8.2, 8.1
Changed item numbers
Section 6.3.2 → Section 6.3.3
CONTENTS
SAFETY PRECAUTIONS..............................................................................................................................A- 1
CONDITIONS OF USE FOR THE PRODUCT .............................................................................................A- 4
REVISIONS ....................................................................................................................................................A- 5
INTRODUCTION............................................................................................................................................A-10
CONTENTS....................................................................................................................................................A-10
ABOUT MANUALS ........................................................................................................................................A-15
COMPLIANCE WITH THE EMC AND LOW VOLTAGE DIRECTIVES.......................................................A-15
1 OVERVIEW 1- 1 to 1-34
1.1 Features .................................................................................................................................................. 1- 1
1.2 Identifying the Compact Remote I/O Module Type................................................................................ 1- 4
1.3 Precautions for use of remote I/O modules ........................................................................................... 1- 5
1.3.1 Input module..................................................................................................................................... 1- 5
1.3.2 Output module.................................................................................................................................. 1-13
1.3.3 Modules with protection functions ................................................................................................... 1-20
1.4 Specification List ..................................................................................................................................... 1-21
1.5 Parts Sold Separately ............................................................................................................................. 1-29
1.6 Recommended Connection Device List................................................................................................. 1-31
1.6.1 Recommended connection devices for low profile waterproof remote I/O module ....................... 1-31
1.6.2 Recommended connection devices for low profile sensor connector (e-CON)
remote I/O module............................................................................................................................ 1-32
1.7 About the Generic, Abbreviated and Technical Terms Used in This Manual....................................... 1-33
3 SPECIFICATIONS 3- 1 to 3- 2
A - 10 A - 10
4.1.7 AJ65SBTB3-16D 24VDC input module
(positive common (sink), negative common (source) loading) ....................................... 4- 9
4.1.8 AJ65SBTB3-16KD 24VDC input module
(positive common (sink), negative common (source) loading) ....................................... 4-11
4.1.9 AJ65SBTB3-16D5 5VDC input module
(positive common (sink), negative common (source) loading) ....................................... 4-13
4.1.10 AJ65SBTB1-32D 24VDC input module
(positive common (sink), negative common (source) loading) ...................................... 4- 15
4.1.11 AJ65SBTB1-32KD 24VDC input module
(positive common (sink), negative common (source) loading) ...................................... 4- 17
4.1.12 AJ65SBTB1-32D1 24VDC input module
(positive common (sink), negative common (source) loading) ....................................... 4-19
4.1.13 AJ65SBTB1-32D5 5VDC input module
(positive common (sink), negative common (source) loading) ....................................... 4-21
4.1.14 AJ65DBTB1-32D 24VDC input module
(positive common (sink), negative common (source) loading) ...................................... 4-23
4.2 Spring Clamp Terminal Block Type Input Module .................................................................................. 4-25
4.2.1 AJ65VBTS3-16D 24VDC input module (positive common (sink type)) .......................................... 4-25
4.2.2 AJ65VBTS3-32D 24VDC input module (positive common (sink type)) .......................................... 4-28
4.3 Sensor Connector (e-CON) Type Input Module ..................................................................................... 4-31
4.3.1 AJ65VBTCE3-8D 24VDC input module (positive common (sink type)).......................................... 4-31
4.3.2 AJ65VBTCE3-16D 24VDC input module (positive common (sink type))........................................ 4-34
4.3.3 AJ65VBTCE3-32D 24VDC input module (positive common (sink type))........................................ 4-37
4.3.4 AJ65VBTCE3-16DE 24VDC input module (negative common (source type)) ............................... 4-40
4.3.5 AJ65VBTCE3-32DE 24VDC input module (negative common (source type)) ............................... 4-43
4.4 One-Touch Connector Type Input Module.............................................................................................. 4-46
4.4.1 AJ65VBTCU3-8D1 24VDC input module (positive common (sink type)) ....................................... 4-46
4.4.2 AJ65SBTC4-16D 24VDC input module
(positive common (sink), negative common (source) loading) ....................................... 4-49
4.4.3 AJ65SBTC4-16DN 24VDC input module (positive common (sink type)) ....................................... 4-52
4.4.4 AJ65SBTC4-16DE 24VDC input module (negative common (source type)) ................................. 4-54
4.4.5 AJ65VBTCU3-16D1 24VDC input module (positive common (sink type)) ..................................... 4-56
4.4.6 AJ65SBTC1-32D 24VDC input module
(positive common (sink), negative common (source) loading) ....................................... 4-59
4.4.7 AJ65SBTC1-32D1 24VDC input module
(positive common (sink), negative common (source) loading) ....................................... 4-61
4.5 FCN Connector Type Input Module......................................................................................................... 4-63
4.5.1 AJ65SBTCF1-32D 24VDC input module
(positive common (sink), negative common (source) loading) ....................................... 4-63
4.6 Waterproof Type Input Module ................................................................................................................ 4-65
4.6.1 AJ65FBTA4-16D 24VDC input module (positive common (sink type)) .......................................... 4-65
4.6.2 AJ65FBTA4-16DE 24VDC input module (negative common (souce type)) ................................... 4-67
4.6.3 AJ65SBTW4-16D 24VDC input module
(positive common (sink), negative common (source) loading) ....................................... 4-69
A - 11 A - 11
5.1.3 AJ65SBTB2-8T transistor output module (sink type)....................................................................... 5- 5
5.1.4 AJ65SBTB2-8T1 transistor output module (sink type)..................................................................... 5- 7
5.1.5 AJ65SBTB1-16T transistor output module (sink type)..................................................................... 5- 9
5.1.6 AJ65SBTB1-16T1 transistor output module (sink type) .................................................................. 5-11
5.1.7 AJ65SBTB2-16T transistor output module (sink type)..................................................................... 5-13
5.1.8 AJ65SBTB2-16T1 transistor output module (sink type) .................................................................. 5-15
5.1.9 AJ65SBTB1-32T transistor output module (sink type)..................................................................... 5-17
5.1.10 AJ65SBTB1-32T1 transistor output module (sink type) ................................................................ 5-19
5.1.11 AJ65SBTB1-8TE transistor output module (source type) ............................................................. 5-21
5.1.12 AJ65SBTB1-16TE transistor output module (source type) ........................................................... 5-23
5.1.13 AJ65SBTB1B-16TE1 transistor output module (source type)....................................................... 5-25
5.1.14 AJ65SBTB1-32TE1 transistor output module (source type) ......................................................... 5-27
5.1.15 AJ65SBTB2N-8R contact output module....................................................................................... 5-29
5.1.16 AJ65SBTB2N-16R contact output module..................................................................................... 5-31
5.1.17 AJ65SBTB2N-8S triac output module............................................................................................ 5-33
5.1.18 AJ65SBTB2N-16S triac output module.......................................................................................... 5-35
5.1.19 AJ65DBTB1-32T1 transistor output module (sink type) ............................................................... 5-37
5.1.20 AJ65DBTB1-32R contact output module ....................................................................................... 5-39
5.2 Spring Clamp Terminal Block Type Output Module .............................................................................. 5-41
5.2.1 AJ65VBTS2-16T transistor output module (sink type) ................................................................... 5-41
5.2.2 AJ65VBTS2-32T transistor output module (sink type) ................................................................... 5-44
5.3 Sensor Connector (e-CON) Type Output module ................................................................................. 5-47
5.3.1 AJ65VBTCE2-8T transistor output module (sink type)................................................................... 5-47
5.3.2 AJ65VBTCE2-16T transistor output module (sink type)................................................................. 5-50
5.3.3 AJ65VBTCE3-16TE transistor output module (source type).......................................................... 5-53
5.4 One-Touch Connector Type Output Module.......................................................................................... 5-56
5.4.1 AJ65VBTCU2-8T transistor output module (sink type).................................................................... 5-56
5.4.2 AJ65VBTCU2-16T transistor output module (sink type).................................................................. 5-59
5.4.3 AJ65SBTC1-32T transistor output module (sink type) .................................................................... 5-62
5.4.4 AJ65SBTC1-32T1 transistor output module (sink type) .................................................................. 5-64
5.5 FCN Connector Type Output Module..................................................................................................... 5-66
5.5.1 AJ65SBTCF1-32T transistor output module (sink type) .................................................................. 5-66
5.6 Waterproof Type Output Module ............................................................................................................ 5-68
5.6.1 AJ65FBTA2-16T transistor output module (sink type)..................................................................... 5-68
5.6.2 AJ65FBTA2-16TE transistor output module (source type).............................................................. 5-70
A - 12 A - 12
6.1.12 AJ65SBTB32-16KDR combined module ....................................................................................... 6-23
6.1.13 AJ65SBTB1-32DT combined module ............................................................................................ 6-25
6.1.14 AJ65SBTB1-32DT1 combined module .......................................................................................... 6-27
6.1.15 AJ65SBTB1-32DT2 combined module .......................................................................................... 6-29
6.1.16 AJ65SBTB1-32KDT2 combined module........................................................................................ 6-31
6.1.17 AJ65SBTB1-32DT3 combined module .......................................................................................... 6-33
6.1.18 AJ65SBTB1-32KDT8 combined module........................................................................................ 6-35
6.1.19 AJ65SBTB1-32DTE1 combined module........................................................................................ 6-37
6.1.20 AJ65DBTB1-32DT1 combined module .......................................................................................... 6-39
6.1.21 AJ65DBTB1-32DR combined module............................................................................................ 6-41
6.2 Spring Clamp Terminal Block Type Combined Module......................................................................... 6-43
6.2.1 AJ65VBTS32-16DT combined module ............................................................................................ 6-43
6.2.2 AJ65VBTS32-32DT combined module ............................................................................................ 6-46
6.3 Sensor Connector (e-CON) Type Combined Module............................................................................ 6-49
6.3.1 AJ65VBTCE32-16DT combined module.......................................................................................... 6-49
6.3.2 AJ65VBTCE3-16DTE combined module ......................................................................................... 6-52
6.3.3 AJ65VBTCE32-32DT combined module.......................................................................................... 6-55
6.3.4 AJ65VBTCE3-32DTE combined module ......................................................................................... 6-58
6.4 One-Touch Connector Type Combined Module.................................................................................... 6-61
6.4.1 AJ65SBTC4-16DT combined module .............................................................................................. 6-61
6.4.2 AJ65SBTC4-16DT2 combined module ............................................................................................ 6-63
6.4.3 AJ65SBTC1-32DT combined module .............................................................................................. 6-65
6.4.4 AJ65SBTC1-32DT1 combined module ............................................................................................ 6-67
6.4.5 AJ65SBTC1-32DT2 combined module ............................................................................................ 6-69
6.4.6 AJ65SBTC1-32DT3 combined module ............................................................................................ 6-71
6.5 FCN Connector Type Combined Module............................................................................................... 6-73
6.5.1 AJ65SBTCF1-32DT combined module............................................................................................ 6-73
6.5.2 AJ65VBTCF1-32DT1 combined module.......................................................................................... 6-75
6.5.3 AJ65VBTCFJ1-32DT1 combined module........................................................................................ 6-78
6.6 Waterproof Type Combined Module ...................................................................................................... 6-81
6.6.1 AJ65FBTA42-16DT combined module ............................................................................................ 6-81
6.6.2 AJ65FBTA42-16DTE combined module .......................................................................................... 6-83
6.6.3 AJ65SBTW4-16DT combined module ............................................................................................. 6-85
A - 13 A - 13
7.5 Connectors and Tools Used for Connecting the FCN Connector Cables ............................................ 7-20
7.6 Attaching and Removing the Protective Cover for the Compact Remote I/O Module ......................... 7-21
7.7 Connection Method of CC-Link Dedicated Cable.................................................................................. 7-24
7.8 Handling of Spring Clamp Terminal Block Type Remote I/O Module................................................... 7-28
7.8.1 Installation and removal of the spring clamp terminal block ........................................................... 7-28
7.8.2 Procedure for wiring the spring clamp terminal block ..................................................................... 7-29
7.9 Attaching Mounting Brackets to the Module .......................................................................................... 7-31
7.9.1 Attachment of mounting brackets .................................................................................................... 7-31
7.9.2 Precautions for attaching mounting brackets .................................................................................. 7-32
7.10 Mounting the DIN Rail Adapter.............................................................................................................. 7-34
7.10.1 Specifications .................................................................................................................................. 7-34
7.10.2 Handling precautions ...................................................................................................................... 7-34
7.10.3 Attaching the DIN rail adapter to the module ................................................................................. 7-34
7.10.4 Mounting the module to a DIN rail .................................................................................................. 7-35
7.11 Common Terminal Block ....................................................................................................................... 7-37
8 TROUBLESHOOTING 8- 1 to 8-11
8.1 Verifying Errors from LED Status ........................................................................................................... 8- 1
8.2 Examples of Errors for Compact Remote I/O Modules ......................................................................... 8- 3
8.2.1 Errors occurring in the input circuit and corrective actions ............................................................. 8- 3
8.2.2 Errors occurring in the output circuit and corrective action............................................................. 8- 5
A - 14 A - 14
ABOUT MANUALS
Related Manuals
Manual Number
Manual Name
(Model Code)
CC-Link System Master/Local Module type AJ61BT11/A1SJ61BT11 User's Manual
IB-66721
This manual describes the system configuration, performance specification, function, handling, wiring
(13J872)
and troubleshooting for AJ61BT11 and A1SJ61BT11. (Sold separately)
A - 15 A - 15
1 OVERVIEW
MELSEC-A
1 OVERVIEW
1 This manual describes the specifications of the compact remote I/O module
(hereinafter referred to as the "compact remote I/O module") used as the remote I/O
station of the CC-Link system.
1.1 Features
The following are the features of the compact remote I/O module:
(1) The remote I/O module is reduced in size yet retains all the
functions of the conventional module
The conventional remote I/O module has furthermore been reduced in size.
[External dimension (comparative example)]
Compact remote I/O module Conventional remote I/O module
AJ65SBTB1-16
AJ65SBTB2-8
AJ65SBTB1-32
Module AJ65SBTB2N-8
AJ65SBTB2-16
model AJ65SBTC1-32
AJ65SBTB1-8 AJ65SBTB2N-16 AJ65BTB1-16 AJ65BTB2-16 AJ65BTC1-32
name AJ65SBTC4-16
AJ65SBTB3-16
AJ65SBTCF1-32
AJ65SBTB32-16
AJ65SBTB3-8
AJ65SBTB32-8
Height 50 (1.97) 65 (2.56)
Width 87.3 (3.44) 118 (4.65) 179 (7.04) 151.9 (5.98) 197.5 (7.78) 165.0 (6.5)
Depth 40 (1.57) 46 (1.81)
1-1 1-1
1 OVERVIEW
MELSEC-A
Connector
Round solderless terminal
The round solderless terminal can
be connected simply by loosening
the screw on the terminal block.
Soldering, peeling of the shield
and screwing are unnecessary.
FCN connector
Square shaped hole
Circular shaped hole
Tool
Ceiling installation
Front installation
Horizontal installation
1-3 1-3
1 OVERVIEW
MELSEC-A
The following shows how to identify the type of a compact remote I/O module:
AJ65 BT -
I/O specifications A: 100 V AC input
D,DN: 24 V DC input
(Positive/negative common shared type, or positive common input)
D5: 5 V DC input (Positive/negative common shared type)
R: Contact output module
S: Triac output
T : Transistor output
DE : 24 V DC input (Negative common input)
DTE : 24 V DC input (Negative common input), transistor output
(source output) combined
TE,TE1: Transistor output (Source output)
DT : 24 V DC input (Positive common input), transistor output
(sink output) combined
DR : 24 V DC input (Positive/negative common shared type),
contact output module
KD : With response speed switching function, 24V DC input
(Positive/negative common shared type)
KDT2 : With response speed switching function, 24V DC input
(Positive common input), transistor output (sink output)
combined
KDT8: With response speed switching function, 12V DC input
(Positive common input), transistor output (sink output)
combined
KDR: With response speed switching function, 24V DC input
(Positive/negative common shared type), contact output
module
1-4 1-4
1 OVERVIEW
MELSEC-A
This section describes the precautions for use of remote I/O modules applicable in the
CC-Link system and their specifications.
• This is a remote I/O module designed specifically for the CC-Link system.
Do not connect the module to other data-link systems, such as the
MELSECNET/MINI.
• 32 points are assigned per station for a compact remote I/O module.
For 16-point modules the 16 points in the second half and for 8-points module the 24
points in the second half remain empty but are not usable.
• Do not install the main circuit lines, high-voltage cables, and load cables other than
those connected to the programmable controller together.
If doing so, the remote I/O module (especially, AJ65SBTB1-16D1, AJ65SBTB1-
32D1, AJ65VBTCU3-8D1, AJ65VBTCU3-16D1, and AJ65SBTC1-32D1) will be
susceptible to noise, surge, and induction.
• When a mechanical contact, such as a relay, is connected to the AJ65SBTB1-16D1,
AJ65SBTB1-32D1, AJ65VBTCU3-8D1, AJ65VBTCU3-16D1, or AJ65SBTC1-32D1,
chattering may be input as a signal.
1-5 1-5
1 OVERVIEW
MELSEC-A
IN IN
Inductive Inductive
load load
Diode Diode
COM COM
[%]
100
Maximum number of simultaneous input points
80
50
0
0 10 20 30 40 55 [ ]
Ambient temperature
1-6 1-6
1 OVERVIEW
MELSEC-A
Vertical installation
100
Horizontal installation
60
50
0 10 20 30 40 45 55
Ambient temperature
1-7 1-7
1 OVERVIEW
MELSEC-A
80 26.4VDC
65 28.8VDC 65 24.0VDC
55 26.4VDC
40 28.8VDC
input points
input points
0 40 50 55 0 25 35 45 55
Ambient temperature Ambient temperature
1-8 1-8
1 OVERVIEW
MELSEC-A
J65VBT
S3-16
A
D
C
D
J65VBTS3-
J65VBT
16D S3-16D
J65VBT
S3-16D
[ ]
100
simultaneous input points
Maximum number of
75
50
0 10 20 30 40 55 [ ]
Ambient temperature
1-9 1-9
1 OVERVIEW
MELSEC-A
J65VBT
S3-16
D
J65VBT J65VBT
S3-16D S3-16D
J65VBT
S3-16D
[ ] [ ]
100 100
simultaneous input points
Maximum number of
75 75
69
(11 points)
50 50
0 10 20 30 40 50 55 [ ] 0 10 20 30 40 50 55 [ ]
Ambient temperature Ambient temperature
1 - 10 1 - 10
1 OVERVIEW
MELSEC-A
J65V
BTS
3-1 6D
C
D
J65V
BTS
3-1 6D
100
simultaneous input points
Maximum number of
75
62.5
J65V
BTS
3-1 6D 50
0 10 20 30 40 50 55
Ambient temperature
Downward installation Derating curve
1 - 11 1 - 11
1 OVERVIEW
MELSEC-A
J 6
5
VB
TS
3 -
6 D
1
J65VBT
S3-16D
[ ]
100
simultaneous input points
75
Maximum number of
50
0 10 20 30 40 50 55 [ ]
Ambient temperature
Downward installation Derating curve
1 - 12 1 - 12
1 OVERVIEW
MELSEC-A
[ ] [ ]
100 100
simultaneous input points
Maximum number of
75
50 50
0 10 20 30 40 50 55 [ ] 0 10 20 30 40 50 55 [ ]
(1) Maximum switching frequency when the module drives inductive load
The output must be on for one second or longer and off for one second or longer.
(2) Load for connection
When connecting a counter or timer that has a DC-DC converter to a transistor
output module (maximum load current 0.1A) as a load, select an output module
whose maximum load current is larger than inrush current of the load.
Selecting an output module by average current of the load may cause a failure of
the module because inrush current flows at a constant frequency at power-on or
during operation due to the connected load.
If an output module needs to be selected by average current of the load, take
either of the following actions to reduce an influence from inrush current.
Output Output
module module
y Connecting a resistor to the load in series y Connecting an inductor to the load in series
1 - 13 1 - 13
1 OVERVIEW
MELSEC-A
Load Load
OUT1 OUT1
Load Load
OUT2 OUT2
COM COM
OUT1 OUT1
OUT2 OUT2
COM COM
OUT OUT
Diode Diode
COM COM
1 - 14 1 - 14
1 OVERVIEW
MELSEC-A
Inductive Inductive
OUT load OUT load
Diode Diode
COM COM
1 - 15 1 - 15
1 OVERVIEW
MELSEC-A
200
100
70
50
10000 times)
30
20
Service life (
100VDC to 120VDC
=7ms to 40ms
10
120VAC COS =1
7
240VAC COS =1
120VAC COS =0.4
5
240VAC COS =0.4
120VAC COS =0.3
30VDC =7ms
3
240VAC COS =0.3
(L/R) : Time constant
cos : Power factor 120VAC COS =0.2
2
240VAC COS =0.2
30VDC =40ms
1
0.1 0.2 0.3 0.5 0.7 1 2 3 5
1 - 16 1 - 16
1 OVERVIEW
MELSEC-A
POINT
When using the module for the application in which the relay contact is frequently
switched, the relay life span should be considered. Therefore, it is recommended
to use a triac output module.
i: Inrush current
i io Approx. 10 to io: Rated current
Approx. 3 to
Inductive load i io
20 times 10 times
i: Inrush current
io: Rated current 0.017 to 0.033 seconds
(1 to 2 cycles)
0.07 to 0.1 seconds
Load of an incandescent bulb Load of a mercury lamp
Approx. 3 to i io Approx. 3
i io *1
10 times i: Inrush current times
i: Inrush current
io: Rated current
io: Rated current
180 to 300 seconds
Approx. 0.33 seconds (3 to 5 minutes)
Lamp load
Load of a fluorescent
i io Approx. 5 to
⎯ ⎯
10 times
i: Inrush current
io: Rated current
Within 10 seconds
2
Capacitive load*
Capacitive Approx. 20 to
i io ⎯ ⎯
load 40 times
i: Inrush current
io: Rated current
1 - 17 1 - 17
1 OVERVIEW
MELSEC-A
*1: When using AC power, impedance of CR must be larger enough than that
of the load. (prevention of a malfunction due to leak current from the CR)
1 - 18 1 - 18
1 OVERVIEW
MELSEC-A
Varistor method Select a cut voltage (Vc) for The recovery time delays
the varistor to meet the slightly.
following condition.
• Vc > power voltage × 1.5(V)
• Vc > power voltage × 1.5(V) ×
√2 (When using AC power)
This method is not effective
when the Vc is too high
POINT
(1) Avoid providing contact protection circuits shown below.
These circuits are effective for preventing an arc at shut-off. However, the
contact welding may occur because the charge current flows to capacitor when
the contact turns on or off.
A DC inductive load is usually harder for switching than a resistor load, but if a
proper protection circuit is configured, the performance will be similar to the
resistor load.
1 - 19 1 - 19
1 OVERVIEW
MELSEC-A
Function Description
Common to protection functions 1. When an overcurrent continues to flow and generates overheat, overheat
protection is activated.
2. The functions are provided for protecting only the circuits inside the module.
A load error may deteriorate output elements or discolour the module case or
printed circuit board due to increase in temperature within the module. If a load
error occurs, turn off the corresponding output immediately and eliminate the error
cause.
Overload protection function 1. Protection is activated under an overload condition of 1 to 3A per point.
2. Protection is automatically reset when the load current drops to the rated value.
Overvoltage protection function 1. This function protects elements from an abrupt surge caused when a coil load is
used.
Overheat protection function 1. The protection of the following modules is activated in units of two points:
AJ65SBTB1-8TE, AJ65SBTB1-16TE, AJ65VBTCE3-16TE, AJ65VBTCE3-16DTE,
AJ65VBTCE3-32DTE
(For example, when protection is activated for either Y0 or Y1 output signals, Y0
and Y1 simultaneously turn off. When the overheat condition continues, the heat is
conducted to other loads and the corresponding protections may also be
activated.)
For the modules except the above, the protection is activated in units of one point.
2. If protection is activated while an output signal is on, the voltage oscillates
between 0V and the load voltage. When the load voltage is 24VDC, the average
voltage during oscillation is approximately 7VDC. (The voltage does not oscillate
when an output signal is off.)
Use an external load that operates at higher than 7VDC.
3. Protection is automatically reset when the temperature falls below the preset
value.
1 - 20 1 - 20
1 OVERVIEW
MELSEC-A
consumption
Input display
Rated input
per module
dimensions
Input current
Reference
Insulation
External
voltage time
method
voltage
Internal
current
Input External Common
Model
format connection connection
ON OFF OFF → ON →
voltage voltage ON OFF
8 points
AJ65SBTB1-8D 8 points Approx. 14V or 6V or 30mA 1 4.1.3
1.5ms or less 1 common
7mA more less
AJ65SBTB1-16D 35mA 4.1.5
16 points Approx. 15V or 3V or 2
AJ65SBTB1-16D1 0.2ms or less 16 points 40mA 4.1.6
5mA more less
1 common
Approx. 15V or 5V or
AJ65DBTB1-32D 10ms or less 1-wire 45mA 3 4.1.14
5mA more less
14V or 6V or terminal
AJ65SBTB1-32D DC input 1.5ms or less block 45mA 4.1.10
Approx. more less
(Positive/ 7mA 14V or 5.5V or
AJ65SBTB1-32KD 14 75mA 4.1.11
Negative more less
3
common) Approx. 15V or 3V or
AJ65SBTB1-32D1 32 points 0.2ms or less 50mA 4.1.12
5mA more less 32 points
Approx. 3.5V or 1.5V or 1 common
AJ65SBTB1-32D5 35mA 4.1.13
4mA more less
1.5ms or less
14V or 6V or 1-wire
AJ65SBTC1-32D 4.4.6
more less
one-touch 45mA
15V or 3V or
AJ65SBTC1-32D1 0.2ms or less connector 4.4.7
more less
AJ65SBTC4-16D 4.4.2
Photocoupler insulation
DC input 2
AJ65SBTC4-16DN (Positive 24VDC 4-wire 4.4.3
LED display
1 : 87.3 (3.44) (W) × 50 (1.97) (H) × 40 (1.57) (D)mm (inch) 8 : 137 (5.39) (W) × 50 (1.97) (H) × 51.5 (2.03) (D)mm (inch)
2 : 118 (4.65) (W) × 50 (1.97) (H) × 40 (1.57) (D)mm (inch) 9 : 222 (8.74) (W) × 50 (1.97) (H) × 51.5 (2.03) (D)mm (inch)
3 : 179 (7.05) (W) × 50 (1.97) (H) × 40 (1.57) (D)mm (inch) 10 : 100 (3.94) (W) × 40 (1.57) (H) × 43.5 (1.71) (D)mm (inch)
4 : 184.7 (7.27) (W) × 57.9 (2.28) (H) × 86 (3.39) (D)mm (inch) 11 : 100 (3.94) (W) × 50 (1.97) (H) × 45.5 (1.79) (D)mm (inch)
5 : 41 (1.61) (W) × 115 (4.53) (H) × 62 (2.44) (D)mm (inch) 12 : 155 (6.10) (W) × 50 (1.97) (H) × 45.5 (1.79) (D)mm (inch)
6 : 60 (2.36) (W) × 115 (4.53) (H) × 62 (2.44) (D)mm (inch) 13 : 64 (2.52) (W) × 170 (6.70) (H) × 80 (3.15) (D)mm (inch)
7 : 60 (2.36) (W) × 200 (7.87) (H) × 48 (1.89) (D)mm (inch) 14 : 0.2ms or less/1.5ms or less/5ms or less/10ms or less
(Depending on the input response speed setting value)
1 - 21 1 - 21
1 OVERVIEW
MELSEC-A
No. of points
consumption
Input display
Rated input
per module
dimensions
Input current
Reference
Insulation
External
voltage time
method
voltage
Internal
current
Input External Common
Model
format connection connection
ON OFF OFF → ON →
voltage voltage ON OFF
DC input
AJ65FBTA4-16D (Positive 2 to 4-wire 4.6.1
common) Approx.
waterproof 40mA 7
DC input 16 points 7mA
connector
AJ65FBTA4-16DE (Negative 4.6.2
common) 16 points
1 common
AJ65VBTS3-16D Spring 35mA 8 4.2.1
clamp
terminal
Photocoupler insulation
LED display
DC input 14V or 6V or
24VDC 1.5ms or less 8 points
AJ65VBTCE3-8D (Positive 8 points 30mA 10 4.3.1
more less 1 common
common)
Approx. 16 points
AJ65VBTCE3-16D 16 points 35mA 11 4.3.2
5mA 1 common
Sensor
connector 32 points
AJ65VBTCE3-32D 32 points (e-CON) 40mA 12 4.3.3
1 common
3-wire type
16 points
AJ65VBTCE3-16DE DC input 16 points 35mA 11 4.3.4
1 common
(Negative
32 points
AJ65VBTCE3-32DE common) 32 points 40mA 12 4.3.5
1 common
1 : 87.3 (3.44) (W) × 50 (1.97) (H) × 40 (1.57) (D)mm (inch) 8 : 137 (5.39) (W) × 50 (1.97) (H) × 51.5 (2.03) (D)mm (inch)
2 : 118 (4.65) (W) × 50 (1.97) (H) × 40 (1.57) (D)mm (inch) 9 : 222 (8.74) (W) × 50 (1.97) (H) × 51.5 (2.03) (D)mm (inch)
3 : 179 (7.05) (W) × 50 (1.97) (H) × 40 (1.57) (D)mm (inch) 10 : 100 (3.94) (W) × 40 (1.57) (H) × 43.5 (1.71) (D)mm (inch)
4 : 184.7 (7.27) (W) × 57.9 (2.28) (H) × 86 (3.39) (D)mm (inch) 11 : 100 (3.94) (W) × 50 (1.97) (H) × 45.5 (1.79) (D)mm (inch)
5 : 41 (1.61) (W) × 115 (4.53) (H) × 62 (2.44) (D)mm (inch) 12 : 155 (6.10) (W) × 50 (1.97) (H) × 45.5 (1.79) (D)mm (inch)
6 : 60 (2.36) (W) × 115 (4.53) (H) × 62 (2.44) (D)mm (inch) 13 : 64 (2.52) (W) × 170 (6.70) (H) × 80 (3.15) (D)mm (inch)
7 : 60 (2.36) (W) × 200 (7.87) (H) × 48 (1.89) (D)mm (inch) 14 : 0.2ms or less/1.5ms or less/5ms or less/10ms or less
(Depending on the input response speed setting value)
1 - 22 1 - 22
1 OVERVIEW
MELSEC-A
No. of points
Maximum load Output response
consumption
dimensions
per module
suppressor
Reference
Insulation
External
method
voltage
Internal
display
Output
current
Surge
Rated
Output current time External Common
load
Model
format OFF → ON → connection connection
1 point 1 common
ON OFF
8 points
AJ65SBTB1-8T 8 points 2.4 A 35mA 1 5.1.1
1-wire 1 common
0.5 A terminal 16 points
AJ65SBTB1-16T Transistor 16 points 3.6 A 50mA 2 5.1.5
block 1 common
output 14
AJ65SBTB1-32T 4.8 A 65mA 3 5.1.9
(sink type)
1-wire 32 points
32 points
AJ65SBTC1-32T 0.1 A 3.2 A one-touch 1 common 60mA 2 5.4.3
connector
8 points
AJ65SBTB1-8T1 8 points 2.4 A 35mA 1 5.1.2
1 common
1-wire
16 points
AJ65SBTB1-16T1 16 points 0.5 A 3.6 A terminal 50mA 2 5.1.6
Transistor 1 common
block
AJ65DBTB1-32T1 output 13 8A 65mA 12 5.1.19
Photocoupler insulation
8 points
AJ65SBTB2N-8R 8 points 4A 85mA 2 5.1.15
1 common
1-wire
Photocoupler insulation
1 : 87.3 (3.44) (W) × 50 (1.97) (H) × 40 (1.57) (D)mm (inch) 10 : 100 (3.94) (W) × 40 (1.57) (H) × 43.5 (1.71)(D)mm (inch)
2 : 118 (4.65) (W) × 50 (1.97) (H) × 40 (1.57) (D)mm (inch) 11 : 100 (3.94) (W) × 50 (1.97) (H) × 45.5 (1.79) (D)mm (inch)
3 : 179 (7.05) (W) × 50 (1.97) (H) × 40 (1.57) (D)mm (inch) 12 : 64 (2.52) (W) × 170 (6.70) (H) × 80 (3.15) (D)mm (inch)
4 : 184.7 (7.27) (W) × 57.9 (2.28) (H) × 86 (3.39) (D)mm (inch) 13 : Leakage current when the transistor output is OFF (0.1mA or less)
5 : 41 (1.61) (W) × 115 (4.53) (H) × 62 (2.44) (D)mm (inch) 14 : Leakage current when the transistor output is OFF (0.25mA or less)
6 : 60 (2.36) (W) × 115 (4.53) (H) × 62 (2.44) (D)mm (inch) 15 : Leakage current when the transistor output is OFF (0.3mA or less)
7 : 60 (2.36) (W) × 200 (7.87) (H) × 48 (1.89) (D)mm (inch) 16 : Leakage current when the triac output is OFF 1.5mA rms or less
8: 137 (5.39) (W) × 50 (1.97) (H) × 51.5 (2.03) (D)mm (inch) (100VAC rms 60Hz), 3mA rms or less (200VAC rms 60Hz)
9: 222 (8.74) (W) × 50 (1.97) (H) × 51.5 (2.03) (D)mm (inch)
1 - 23 1 - 23
1 OVERVIEW
MELSEC-A
No. of points
Maximum load Output response
consumption
dimensions
per module
suppressor
Reference
Insulation
External
method
voltage
Internal
display
Output
current
Surge
Rated
Output current time External Common
load
Model
format OFF → ON → connection connection
1 point 1 common
ON OFF
0.5ms 1.5ms 1-wire FCN 32 points
AJ65SBTCF1-32T 32 points 3.2 A 60mA 2 5.5.1
Transistor or less or less connector 1 common
output 13 0.1 A 2-wire 8 points
AJ65VBTCU2-8T 8 points 0.8 A 1ms 1ms 35mA 5 5.4.1
(sink type) one-touch 1 common
or less or less
AJ65VBTCU2-16T 1.6 A connector 40mA 6 5.4.2
Transistor
AJ65FBTA2-16T output 14 0.5 A 2-wire 50mA 7 5.6.1
(sink type) 0.5ms 1.5ms
16 points waterproof
Transistor
Photocoupler insulation
or less or less
connector 16 points
AJ65FBTA2-16TE output 15 1.0 A 50mA 7 5.6.2
1 common
LED display
(source type) 4.0 A
AJ65VBTS2-16T 12/24 Zener Spring 45mA 8 5.2.1
VDC diode clamp
0.5 A terminal
AJ65VBTS2-32T Transistor 32 points block 60mA 9 5.2.2
output 12 2-wire type
(sink type) Sensor 8 points
AJ65VBTCE2-8T 8 points 0.8 A 1ms 1ms connector 35mA 5.3.1
1 common 10
or less or less (e-CON)
AJ65VBTCE2-16T 2-wire type 5.3.2
0.1 A
Sensor 16 points
Transistor 16 points 1.6 A 45mA
AJ65VBTCE3- connector 1 common 11
output 13 5.3.3
16TE (e-CON)
(source type)
3-wire type
1 : 87.3 (3.44) (W) × 50 (1.97) (H) × 40 (1.57) (D)mm (inch) 10 : 100 (3.94) (W) × 40 (1.57) (H) × 43.5 (1.71)(D)mm (inch)
2 : 118 (4.65) (W) × 50 (1.97) (H) × 40 (1.57) (D)mm (inch) 11 : 100 (3.94) (W) × 50 (1.97) (H) × 45.5 (1.79) (D)mm (inch)
3 : 179 (7.05) (W) × 50 (1.97) (H) × 40 (1.57) (D)mm (inch) 12 : 64 (2.52) (W) × 170 (6.70) (H) × 80 (3.15) (D)mm (inch)
4 : 184.7 (7.27) (W) × 57.9 (2.28) (H) × 86 (3.39) (D)mm (inch) 13 : Leakage current when the transistor output is OFF (0.1mA or less)
5 : 41 (1.61) (W) × 115 (4.53) (H) × 62 (2.44) (D)mm (inch) 14 : Leakage current when the transistor output is OFF (0.25mA or less)
6 : 60 (2.36) (W) × 115 (4.53) (H) × 62 (2.44) (D)mm (inch) 15 : Leakage current when the transistor output is OFF (0.3mA or less)
7 : 60 (2.36) (W) × 200 (7.87) (H) × 48 (1.89) (D)mm (inch) 16 : Leakage current when the triac output is OFF 1.5mA rms or less
8: 137 (5.39) (W) × 50 (1.97) (H) × 51.5 (2.03) (D)mm (inch) (100VAC rms 60Hz), 3mA rms or less (200VAC rms 60Hz)
9: 222 (8.74) (W) × 50 (1.97) (H) × 51.5 (2.03) (D)mm (inch)
1 - 24 1 - 24
1 OVERVIEW
MELSEC-A
No. of points
Input current
Operation Input response
consumption
Input display
Rated input
per module
dimensions
Reference
Insulation
External
Division
voltage time
method
voltage
Internal
current
Input External Common
Model
format connection connection
ON OFF OFF → ON →
voltage voltage ON OFF
with output)
16 5V or 16 points
AJ65DBTB1-32DT1 10ms or less 55mA 5 6.1.20
LED display
1-wire
DC input terminal 32 points
AJ65SBTB1-32DTE1 (Negative 1 common (shared 50mA 2 6.1.19
common) block with output)
6V or 1.5ms or less 16 points
8 Approx. 14V or less
AJ65SBTB1-16DT2 1 common (shared 50mA 1 6.1.5
points 7mA more with output)
AJ65SBTB1-32DT2 32 points 60mA 6.1.15
16
5.5V or 1 common (shared 2
AJ65SBTB1-32KDT2 points 11 65mA
less with output) 6.1.16
8 16 points
AJ65SBTB1-16DT3 Approx. 15V or 3V or 1 common (shared 55mA 1 6.1.6
points 0.2ms or less
5mA more less with output)
AJ65SBTB1-32DT3 32 points 60mA 6.1.17
16
12 Approx. 5.6V or 2.4V or 1 common (shared 2
AJ65SBTB1-32KDT8 points 11 65mA
VDC 11mA more less with output) 6.1.18
DC input
(Positive 8 points
4
AJ65SBTB32-8DT common) points 1 common (shared 45mA 1 6.1.1
with output)
8 16 points
AJ65SBTB32-16DT 6V or 1 common (shared 50mA 2 6.1.7
points 1.5ms or less Input 3-wire with output)
24 Approx. 14V or less
Output 8 points
4 VDC 7mA more
AJ65SBTB32-8DT2 2-wire 1 common (shared 45mA 1 6.1.2
points terminal with output)
AJ65SBTB32-16DT2 block 50mA 6.1.8
8 5.5V or 16 points
AJ65SBTB32-16KDT2 less 11 1 common (shared 55mA 2 6.1.9
points
12 Approx. 5.6V or 2.4V or with output)
AJ65SBTB32-16KDT8 11 55mA 6.1.10
VDC 11mA more less
1 : 118 (4.65) (W) × 50 (1.97) (H) × 40 (1.57) (D)mm (inch) 7 : 137 (5.39) (W) × 50 (1.97) (H) × 51.5 (2.03) (D)mm (inch)
2 : 179 (7.05) (W) × 50 (1.97) (H) × 40 (1.57) (D)mm (inch) 8 : 222 (8.74) (W) × 50 (1.97) (H) × 51.5 (2.03) (D)mm (inch)
3 : 184.7 (7.27) (W) × 57.9 (2.28) (H) × 86 (3.39) (D)mm (inch) 9 : 100 (3.94) (W) × 50 (1.97) (H) × 41.5 (1.63) (D)mm (inch)
4 : 41 (1.61) (W) × 115 (4.53) (H) × 67 (2.64) (D)mm (inch) 10 : 155 (6.10) (W) × 50 (1.97) (H) × 45.5 (1.79) (D)mm (inch)
5 : 64 (2.52) (W) × 170 (6.70) (H) × 80 (3.15) (D)mm (inch) 11 : 0.2ms or less/1.5ms or less/5ms or less/10ms or less
6 : 60 (2.36) (W) × 200 (7.87) (H) × 48 (1.89) (D)mm (inch) (Depending on the input response speed setting value)
1 - 25 1 - 25
1 OVERVIEW
MELSEC-A
No. of points
Input current
Operation Input response
consumption
Input display
Rated input
per module
dimensions
Reference
Insulation
External
Division
voltage time
method
voltage
Internal
current
External Common
Model Input format
connection connection
ON OFF OFF → ON →
voltage voltage ON OFF
6V or Input
AJ65SBTB32-16DR 1.5ms or less 3-wire 85mA 6.1.11
less
8 Approx. 14V or Output 8 points
2
AJ65SBTB32- points 7mA more 5.5V or 2-wire 1 common
11 terminal 100mA 6.1.12
16KDR DC input less
block
(Positive/
negative 1-wire
15V or 5V or
AJ65DBTB1-32DR common) 10ms or less terminal 60mA 5 6.1.21
more less
block
16 Approx. 14V or 6V or 16 points
AJ65SBTCF1-32DT 1.5ms or less 1 6.5.1
points 5mA more less 1 common
1-wire
AJ65VBTCF1-32DT1 one-touch 4 6.5.2
15V or 3V or 0.2ms or less connector
AJ65VBTCFJ1- 50mA
more less 6.5.3
32DT1 DC input
Photocoupler insulation
(Positive
AJ65FBTA42-16DT common) 6.6.1
2 to 4-wire 8 points 6
LED display
Approx.
waterproof 1 common (Shared
Input side
DC input 24 7mA
AJ65FBTA42-16DTE (Negative 8 connector with output) 45mA 6.6.2
points VDC
common)
Spring 16 points
AJ65VBTS32-16DT clamp 1 common (shared 40mA 7 6.2.1
terminal with output)
16 block 16 points
AJ65VBTS32-32DT 3-wire type 50mA 8 6.2.2
DC input points 1 common
(Positive 14V or 6V or 16 points
8 more less 1.5ms or less
AJ65VBTCE32-16DT common) 1 common (shared 40mA 9 6.3.1
points
Approx. with output)
16 5mA 32 points
AJ65VBTCE32-32DT points Sensor 1 common (shared 45mA 10 6.3.3
connector with output)
(e-CON) 16 points
8 3-wire type 1 common (shared
AJ65VBTCE3-16DTE 40mA 9 6.3.2
DC input points
with output)
(Negative
common) 16 32 points
AJ65VBTCE3-32DTE points 1 common (shared 45mA 10 6.3.4
with output)
1 : 118 (4.65) (W) × 50 (1.97) (H) × 40 (1.57) (D)mm (inch) 7 : 137 (5.39) (W) × 50 (1.97) (H) × 51.5 (2.03) (D)mm (inch)
2 : 179 (7.05) (W) × 50 (1.97) (H) × 40 (1.57) (D)mm (inch) 8 : 222 (8.74) (W) × 50 (1.97) (H) × 51.5 (2.03) (D)mm (inch)
3 : 184.7 (7.27) (W) × 57.9 (2.28) (H) × 86 (3.39) (D)mm (inch) 9 : 100 (3.94) (W) × 50 (1.97) (H) × 41.5 (1.63) (D)mm (inch)
4 : 41 (1.61) (W) × 115 (4.53) (H) × 67 (2.64) (D)mm (inch) 10 : 155 (6.10) (W) × 50 (1.97) (H) × 45.5 (1.79) (D)mm (inch)
5 : 64 (2.52) (W) × 170 (6.70) (H) × 80 (3.15) (D)mm (inch) 11 : 0.2ms or less/1.5ms or less/5ms or less/10ms or less
6 : 60 (2.36) (W) × 200 (7.87) (H) × 48 (1.89) (D)mm (inch) (Depending on the input response speed setting value)
1 - 26 1 - 26
1 OVERVIEW
MELSEC-A
Internal current
Output display
Maximum load Output
No. of points
consumption
dimensions
per module
suppressor
Rated load
Reference
Insulation
External
current response time
Division
method
voltage
Surge
Output External Common
Model
format connection connection
OFF → ON →
1 point 1 common
ON OFF
AJ65SBTC1-32DT Transistor
output 13
AJ65SBTC1-32DT1 (sink type) 1-wire 32 points
16
0.1A 1.6A one-touch 1 common
Transistor points
AJ65SBTC1-32DT2 connector (shared with input)
output 12
AJ65SBTC1-32DT3 (sink type)
Transistor
AJ65SBTC4-16DT output 13
(sink type) 4-wire
one-touch
Transistor connector 16 points
8
AJ65SBTC4-16DT2 output 12 points 1 common
(shared with input)
(sink type) 24 2.4A
VDC 4-wire
AJ65SBTW4-16DT waterproof
connector
16 points
8
AJ65SBTB1-16DT 1 common (shared
points
with input)
Transistor 32 points
16
AJ65SBTB1-32DT output 13 points 3.6A 1 common (shared
(sink type) with input)
16 points
8
AJ65SBTB1-16DT1 2.4A 1 common
points
(shared with input)
32 points
AJ65SBTB1-32DT1 3.6A 1 common
(shared with input)
Photocoupler insulation
Transistor
12/24 16 points
AJ65DBTB1-32DT1 output 12 16 4A
VDC 1 common
LED display
1-wire
Transistor 0.5ms 1.5ms Zener terminal
32 points See input side
or less or less diode block
AJ65SBTB1-32DTE1 output 12 3.6A 1 common
(source (shared with input)
type)
0.5A 16 points
8
AJ65SBTB1-16DT2 2.4A 1 common
points
24 (shared with input)
AJ65SBTB1-32DT2 VDC 32 points
16
3.6A 1 common
AJ65SBTB1-32KDT2 Transistor points (shared with input)
output 12 16 points
(sink type) 8
AJ65SBTB1-16DT3 2.4A 1 common
points
(shared with input)
AJ65SBTB1-32DT3 32 points
16
12 3.6A 1 common
AJ65SBTB1-32KDT8 points
VDC (shared with input)
8 points
4
AJ65SBTB32-8DT Transistor points 1.2A 1 common
(shared with input)
output 13
16 points
(sink type) 8
AJ65SBTB32-16DT 2.4A 1 common
points
(shared with input)
24 Input 3-wire 8 points
4
AJ65SBTB32-8DT2 VDC 1.2A Output 1 common
points
2-wire (shared with input)
terminal
AJ65SBTB32-16DT2 Transistor block
output 12
16 points
8
AJ65SBTB32-16KDT2 (sink type) points 2.4A 1 common
(shared with input)
12
AJ65SBTB32-16KDT8
VDC
1 - 27 1 - 27
1 OVERVIEW
MELSEC-A
Internal current
Output display
Maximum load Output
No. of points
consumption
dimensions
per module
suppressor
Rated load
Reference
Insulation
External
current response time
Division
method
voltage
Surge
External Common
Model Output format
connection connection
OFF → ON →
1 point 1 common
ON OFF
Input 3-wire
AJ65SBTB32-16DR
insulation
8 Output 4 points
Relay
24 2-wire
points 1 common
AJ65SBTB32-16KDR Contact output VDC 10ms 12ms terminal
2A 4A None
240 or less or less block
VAC 1-wire 8 points
16
AJ65DBTB1-32DR terminal
points 1 common
block
AJ65SBTCF1-32DT 0.5ms 1.5ms
12/24 or less or less
Transistor 1-wire
16 VDC 16 points
AJ65VBTCF1-32DT1 output 12 points 0.1A 1.6A FCN
1ms 1ms 1 common
(sink type) connector
AJ65VBTCFJ1- or less or less
32DT1
Transistor
AJ65FBTA42-16DT output 13 0.5A 2.4A
(sink type) 2-wire 8 points
24 0.5ms 1.5ms
waterproof 1 common
LED display
Output side
or less or less
Photocoupler insulation
1 - 28 1 - 28
1 OVERVIEW
MELSEC-A
1 - 29 1 - 29
1 OVERVIEW
MELSEC-A
Mitsubishi
Applicable module
model name
Input : AJ65SBTB1-8D
A6CVR-8 Output : AJ65SBTB1-8T AJ65SBTB1-8TE AJ65SBTB1-8T1
Repeater : AJ65SBT-RPT
Input : AJ65SBTB1-16D AJ65SBTB1-16D1 AJ65SBTC1-32D AJ65SBTC1-32D1
AJ65SBTC4-16D AJ65SBTC4-16DN AJ65SBTC4-16DE AJ65SBTB3-8D
AJ65SBTB2-8A AJ65SBTB2N-8A
Output : AJ65SBTB1-16T AJ65SBTC1-32T AJ65SBTB1-16T1 AJ65SBTB2-8T
AJ65SBTB1-16TE AJ65SBTB2-8R AJ65SBTB2-8S AJ65SBTB2N-8R
A6CVR-16
AJ65SBTB2N-8S AJ65SBTB2-8T1
Combined : AJ65SBTC1-32DT AJ65SBTC1-32DT1 AJ65SBTC4-16DT AJ65SBTB1-6DT
Protect cover
AJ65SBTB1-16DT1 AJ65SBTB1-16DT2 AJ65SBTB32-8DT AJ65SBTC1-32DT2
for compact
AJ65SBTC1-32DT3 AJ65SBTC4-16DT2 AJ65SBTB1-16DT3 AJ65SBTB32-8DT2
remote I/O
Optical Repeater : AJ65SBT-RPS AJ65SBT-RPG
module
Input : AJ65SBTB1-32D AJ65SBTB1-32D1 AJ65SBTB2-16A AJ65SBTB2N-16A
(including 10)
AJ65SBTB3-16D
Output : AJ65SBTB1-32T AJ65SBTB1-32T1 AJ65SBTB2-16T AJ65SBTB2-16R
A6CVR-32
AJ65SBTB2-16S AJ65SBTB2N-16R AJ65SBTB2N-16S AJ65SBTB2-16T1
Combined : AJ65SBTB1-32DT AJ65SBTB1-32DT1 AJ65SBTB1-32DT2 AJ65SBTB32-16DT
AJ65SBTB1-32DT3 AJ65SBTB32-16DT2
Input : AJ65VBTCE3-8D
A6CVR-VCE8
Output : AJ65VBTCE2-8T
Input : AJ65VBTCE3-16D AJ65VBTCE3-16DE
A6CVR-VCE16 Output : AJ65VBTCE2-16T AJ65VBTCE3-16TE
Combined : AJ65VBTCE32-16DT AJ65VBTCE3-16DTE
Input : AJ65DBTB1-32D
DIN adapter A6DIN1C Output : AJ65DBTB1-32T1 AJ65DBTB1-32R
Combined : AJ65DBTB1-32DT1 AJ65DBTB1-32DR
Common Input : AJ65DBTB1-32D
Terminal A2CCOM-TB Output : AJ65DBTB1-32T1 AJ65DBTB1-32R
Block Combined : AJ65DBTB1-32DT1 AJ65DBTB1-32DR
1 - 30 1 - 30
1 OVERVIEW
MELSEC-A
1.6.1 Recommended connection devices for low profile waterproof remote I/O module
The following shows communication devices needed for use of the low profile
waterproof type remote I/O module (AJ65FBTA -16 ).
(2) Power Supply Module - Waterproof Plug (Female) 5-pin only can
be used.
Model Name Maker Specifications Connection Cable Diameter
ELKA 5012 PG7 φ4.0 to 6.0mm
HIRSCHMANN M12-5-pin Female Straight Type
ELKA 5012 PG9 φ6.0 to 8.0mm
ELWIKA 5012 PG7 φ4.0 to 6.0mm
HIRSCHMANN M12-5-pin Female Right-angle Type
ELWIKA 5012 PG9 φ6.0 to 8.0mm
1 - 31 1 - 31
1 OVERVIEW
MELSEC-A
1.6.2 Recommended connection devices for low profile sensor connector (e-CON) remote
I/O module
The following shows communication devices needed for use of the sensor connector
(e-CON) remote I/O module (AJ65VBTCE - ).
For how to wire the sensor connector (e-CON), refer to the catalog of the
corresponding maker.
1 - 32 1 - 32
1 OVERVIEW
MELSEC-A
1.7 About the Generic, Abbreviated and Technical Terms Used in This Manual
The abbreviated and technical terms used in this manual are listed below:
Generic/abbreviated/
Description
technical term
Generic term for the AJ61BT11, A1SJ61BT11, AJ61QBT11, A1SJ61QBT11, QJ61BT11 and
Master/local module
LJ61BT11 CC-Link system master/local modules
Compact remote I/O module Generic term for the AJ65SBT - CC-Link system compact remote I/O modules
Conventional remote I/O
Generic term for the AJ65BT - CC-Link system remote I/O modules
module
Generic term for the AJ65BT - /AJ65SBT - /AJ65V - /AJ65F - CC-Link
Remote I/O module
system remote I/O modules
Input module Generic term for the AJ65SBT - A/D(1) remote I/O modules
Output module Generic term for the AJ65SBT - R/T /T1/TE remote I/O modules
Combined module Generic term for the AJ65SBT - DT(1) remote I/O modules
Waterproof type remote I/O
Generic term for the AJ65SBTW4-16 remote I/O modules
module
Low profile waterproof type
Generic term for the AJ65FBTA -16 remote I/O modules
remote I/O module
Spring clamp terminal block
Generic term for the AJ65VBTS - remote I/O modules
type remote I/O module
Sensor connector (e-CON)
Generic term for the AJ65VBTCE - remote I/O modules
type remote I/O module
1 - 33 1 - 33
1 OVERVIEW
MELSEC-A
MEMO
1 - 34 1 - 34
2 NAMES AND SETTINGS FOR EACH PART
MELSEC-A
The names and settings for the components of the compact remote I/O module are
shown below:
AJ65SBTB1-8 (Terminal-block 8 point module, 1-wire)
2 1) 4) 2)
ON
A J65SBTB1-8D
DA DG +24V 24G X0 X2 X4 X6 COM
DB SLD (FG) X1 X3 X5 X7 COM
9) 11)
ON
AJ65SBTB1-16D
DA DG +24V 24G X0 X2 X4 X6 X8 XA XC XE COM
DB SLD (FG) X1 X3 X5 X7 X9 XB XD XF COM
11)
9)
AJ65SBTB1B-16 (Module with 1-wire terminal block, 2-common type, and 16 points)
1) 4) 2)
ON
AJ65SBTB1B-16TE1
DA DG +24V 24G Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 YA YB YC YD YE YF NC
DB SLD (FG) COM1- COM1- COM1- COM1- COM1- COM1- CTL1- COM1+ COM2- COM2- COM2- COM2- COM2- COM2- CTL2- COM2+ NC
11) 9) 11)
2-1 2-1
2 NAMES AND SETTINGS FOR EACH PART
MELSEC-A
ON
AJ65SBTB1-32D
DA DG +24V 24G X0 X2 X4 X6 X8 XA XC XE X10 X12 X14 X16 X18 X1A X1C X1E COM
DB SLD (FG) X1 X3 X5 X7 X9 XB XD XF X11 X13 X15 X17 X19 X1B X1D X1F COM
2
9)
11) 11)
11) 9) 11)
1) 6) 4) 2)
9) 11) 10) 9)
2-2 2-2
2 NAMES AND SETTINGS FOR EACH PART
MELSEC-A
A J65SBTC4-16DN
DA DG +24V 24G
X0 X1 X2 X3 X4 X5 X6 X7 COM+
DB SLD (FG) Y8 Y9 YA YB YC YD YE YF COM-
+24V +24V +24V +24V +24V +24V +24V +24V
24G 24G 24G 24G 24G 24G 24G 24G
9) 11) 10) 9)
(AJ65SBTC4-16D only)
A J65SBTCF1-32D X10-X1F
DA DG +24V 24G X10 X11 X12 X13 X14 X15 X16 X17 X18 X19 X1A X1B X1C X1D X1E X1F NC NC NC NC
9) 11) 10)
2-3 2-3
2 NAMES AND SETTINGS FOR EACH PART
MELSEC-A
9) 11)
11) 9) 11)
1) 4) 2)
ON
AJ65SBTB2-8T
DA DG +24V 24G Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 DC24V
DB SLD (FG) COM COM COM COM COM COM COM COM DC24G
9) 11)
2-4 2-4
2 NAMES AND SETTINGS FOR EACH PART
MELSEC-A
ON
AJ65SBTB2-16T
DA DG +24V 24G Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 YA YB YC YD YE YF DC24V
DB SLD (FG) COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM DC24G
11) 9) 11)
ON
AJ65SBTB3-8D
DA DG +24V 24G X0 X1 X2 X3 X4 X5 X6 X7 DC24A
DB SLD (FG) COMA COMB COMA COMB COMA COMB COMA COMB DC24B
9) 11)
1) 4) 2)
ON
AJ65SBTB3-16D
DA DG +24V 24G X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF DC24A
DB SLD (FG) COMA COMB COMA COMB COMA COMB COMA COMB COMA COMB COMA COMB COMA COMB COMA COMB DC24B
11) 9) 11)
2-5 2-5
2 NAMES AND SETTINGS FOR EACH PART
MELSEC-A
11) 9) 11)
1) 4) 2)
ON
AJ65SBTB32-8DT
DA DG +24V 24G X0 X1 X2 X3 Y8 Y9 YA YB DC24V
DB SLD (FG) COM+ COM- COM+ COM- COM+ COM+ COM+ COM+ DC24G
9) 11)
ON
AJ65SBTB32-16DT
DA DG +24V 24G X0 X1 X2 X3 X4 X5 X6 X7 Y8 Y9 YA YB YC YD YE YF DC24A
DB SLD (FG) COM+ COM- COM+ COM- COM+ COM- COM+ COM- COM+ COM+ COM+ COM+ COM+ COM+ COM+ COM+ DC24B
9)
11) 11)
2-6 2-6
2 NAMES AND SETTINGS FOR EACH PART
MELSEC-A
9)
11) 11)
YD
11) 9) 11)
11) 9) 11)
2-7 2-7
2 NAMES AND SETTINGS FOR EACH PART
MELSEC-A
AJ65DBTB1-32D
6 PW L RUN L ERR.
5 0 ~0
1
5) 4 1 0 8 10 18
3 2
STATI ON NO. 1 9 11 19
7 8 2 A 12 1A
5
6
4
3 2
9
1
0 ~
1 3
4
B
C
13
14
1B
1C
1)
5 D 15 1D
3) B RATE
4
3 2
1
0
6
7
E
F
16
17
1E
1F
DA NC
DG NC
DB +24V
NC NC
SLD
( FG)
NC NC
24G 24G
X0 X10
X1 X11
X2 X12
X3 X13
9) X4 X14 9)
X5 X15
X6 X16
X7 X17
COM1 COM3
X8 X18
X9 X19
XA X1A
XB X1B
XC X1C
XD X1D
XE X1E
XF X1F
COM4
COM2
AJ65DBTB1
- 32D
2-8 2-8
2 NAMES AND SETTINGS FOR EACH PART
MELSEC-A
2-9 2-9
2 NAMES AND SETTINGS FOR EACH PART
MELSEC-A
*1
5) Station number setting switch Set the station number within the range of 1 to 64.
• Use "×10" for the tens place.
• Use "×1" for the ones place.
*2
6) Indication selector switch When the switch is set to "X0-XF", LEDs indicate the ON/OFF status of X0 to
XF.
When the switch is set to "X10-X1F", LEDs indicate the ON/OFF status of X10
to X1F.
7) Sink/source switch Switches the input type (sink or source).
(For AJ65SBTC1-16D only) Open the module top cover to set the switch.
<When setting for sink type> <When setting for source type>
SOURCE SOURCE
Switch
SINK SINK
2 - 10 2 - 10
2 NAMES AND SETTINGS FOR EACH PART
MELSEC-A
2)
3)
9) SINK SOURCE
6) 1)
STATION NO.
MITSUBISHI AJ65SBTW4-16DT
5)
2 - 11 2 - 11
2 NAMES AND SETTINGS FOR EACH PART
MELSEC-A
Switch
SINK SINK
2 - 12 2 - 12
2 NAMES AND SETTINGS FOR EACH PART
MELSEC-A
40
20
10
8 3)
4
2
1
4
2 2)
1
AJ65VBTCU3-8D1
CON
A
5)
CON
B
X0 PW
L RUN
X1
L ERR
X2 1)
0
1
2
X3
3
7) 4
5
8)
X4 6
7
X5
X6
X7
CON
C
6)
CON
D
2 - 13 2 - 13
2 NAMES AND SETTINGS FOR EACH PART
MELSEC-A
40
20
10
8 3)
4
2
1
4
2 2)
1
AJ65VBTCU3-16D1
CON
A
5)
CON
B
PW
L RUN
L ERR
0
1
2
3
7) 4 1) 8)
5
6
7
8
9
A
B
C
D
E
X0 to X7 X8 to XF F
CON
C
6)
CON
D
2 - 14 2 - 14
2 NAMES AND SETTINGS FOR EACH PART
MELSEC-A
40
20
10
8 3)
4
2
1
4
2 2)
1
AJ65VBTCF1-32DT1
LINK X0 Y10
to to 4)
CON.A CON.B XF Y1F
PW
L RUN
5) L ERR
0
1
2
3
4
5 8)
6
7 1)
8
9
A
B
PW/AUX.
C
CON.C CON.D D
E
F
6)
7)
2 - 15 2 - 15
2 NAMES AND SETTINGS FOR EACH PART
MELSEC-A
2 - 16 2 - 16
2 NAMES AND SETTINGS FOR EACH PART
MELSEC-A
2 - 17 2 - 17
2 NAMES AND SETTINGS FOR EACH PART
MELSEC-A
TERMINATION
110 130
ON 5) 5)
1 2 a b
9)
ON
40 20 10 8 4 2 1 4 2 1
STATION NO B RATE
Communication
adapter AJ65FBTA42-16DTE
PROTECT
Y8
Y9
YA
YB 1)
YC
YD
YE
YF
6) 6)
c d
Y
Y
Y
Y
7) 7)
Y
Y
Y
Y
2 - 18 2 - 18
2 NAMES AND SETTINGS FOR EACH PART
MELSEC-A
2 - 19 2 - 19
2 NAMES AND SETTINGS FOR EACH PART
MELSEC-A
2 - 20 2 - 20
2 NAMES AND SETTINGS FOR EACH PART
MELSEC-A
8 9 A B C D E F
2) NC X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF
COM+ COM+
9)
COM- COM-
CON A B C D
9) 10) 5) 6) 8)
3)
AJ65VBTS3-32D
0 1 2 3 4 5 6 7
2)
8 9 A B CD E F
NC X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF NC X10 X11 X12 X13 X14 X15 X16 X17 X18 X19 X1A X1B X1C X1D X1E X1F
CON A B C D
9) 5) 6) 8) 8)
2 - 21 2 - 21
2 NAMES AND SETTINGS FOR EACH PART
MELSEC-A
2 - 22 2 - 22
2 NAMES AND SETTINGS FOR EACH PART
MELSEC-A
2 - 23 2 - 23
2 NAMES AND SETTINGS FOR EACH PART
MELSEC-A
1 40 S
T
2 20 A
3 10 T 9)
4) 4 8
I
O
5 4 N CON ON
6 2 N A
1
2
3
4
7 1 O.
5)
5
6
7
8 4 B
R
B
8
9
10
3) 9 2 A
T
40
20
S
T
10 1
A
10
E C T
I
10)
8 O
6)
4 N
2 N
1 O.
D 4 B
R
2 A
1 T
E
A J65VBTCE3-8D
PW
X0 L RUN
L ERR.
X1
0
X2
1
2
1)
3
7) X3 4
5
10)
6
X4 7
X5
X6
X7
9) 8)
4) 0 1 2 3 4 5 6 7
3)
8 9 A B C D E F
9)
X 0 1 2 3 4 5 6 7
8)
CON A B C D X 8 9 A B C D E F
9) 10) 5) 6) 8)
4)
B RATE STATI ON NO.
0 1 2 3 4 5 6 7
3)
8 9 A B C D E F
X 0 1 2 3 4 5 6 7 8 9 A B C D E F 9)
8)
CON A B C D X 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F
9) 5) 6) 8) 8)
10)
2 - 24 2 - 24
2 NAMES AND SETTINGS FOR EACH PART
MELSEC-A
2 - 25 2 - 25
2 NAMES AND SETTINGS FOR EACH PART
MELSEC-A
2 - 26 2 - 26
3 SPECIFICATIONS
MELSEC-A
3 SPECIFICATIONS
This section explains the compact Remote I/O Module general specifications.
Item Specifications
6
Operating ambient temperature 0 to 55°C
6
Storage ambient temperature -20 to 75°C
10 to 90% RH, No condensation
Operating ambient humidity 4
(The waterproof type remote I/O module is compliant with IP67. )
Storage ambient humidity 10 to 90% RH, No condensation
Constant Half
Frequency Sweep Count
3 acceleration amplitude
Compliant When there is 5 to 8.4Hz — 3.5mm 10 times each
with JIS B intermittent in X, Y and Z
Vibration resistance 8.4 to 150Hz 9.8m/s
2
—
3502, vibration axis
IEC 61131-2 When there is
5 to 8.4Hz — 1.75mm
continuous 2
—
vibration 8.4 to 150Hz 4.9m/s —
2
Shock resistance Compliant with JIS B 3502, IEC 61131-2 (147m/s , 3 times in each of 3 directions X,Y,Z)
Operating environment No corrosive gas present
3
Operating height 0 to 2000m
5
Installation area On the control board
1
Over-voltage category II or less
2
Pollution rate 2 or less
1 Indicates the location where the device is connected from the public cable network to the
device structure wiring area.
Category II applies to the devices to which the power is supplied from a fixed equipment.
Surge withstand voltage for devices with up to 300V of rated voltage is 2500V.
2 This is an index which indicates the degree of conductive object generation in the
environment Pollution level 2 is when only non-conductive pollution occurs.
A temporary conductivity caused by condensation must be expected occasionally.
3 Do not use or store the programmable controller in the environment where the pressure is
higher than the atmospheric pressure at sea level. Otherwise, malfunction may result. To use
the programmable controller in high-pressure environment, contact your nearest Mitsubishi
representative.
4 Applicable only when all waterproof connectors are being used, or when waterproof caps are
installed on unused waterproof connectors or feed-through tubes. (Feed-through tubes are
used in the AJ65SBTW -16 only.)
5 It can also be used in an environment other than on the control panel if the conditions such as
usage ambient temperature and humidity are satisfied.
6 In the case of the waterproof remote I/O module, usage ambient temperature and storage
ambient temperature are the following. (AJ65SBTW -16 only)
Item Specification
Usage ambient temperature 0 to 45°C
Not wired (individual product) -20 to 65°C
Storage ambient temperature
Wired (after cable installation) -10 to 55°C
REMARK
For compliance of this product with the EMC and Low Voltage Directives, refer to the
user's manual for the CPU module used.
3-1 3-1
3 SPECIFICATIONS
MELSEC-A
MEMO
3-2 3-2
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
This chapter describes the specifications for a input module that can be connected to
the CC-Link system.
X7 COMA
Number of occupied stations 32-point assignment/station (8 points used)
Module power supply Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
X6
Current 35mA or lower (at 24VDC and all points ON)
Noise immunity Noise voltage: 1500Vp-p (AC type), 500Vp-p (DC type), noise width 1µs,
X5
noise frequency 25 to 60Hz (noise simulator condition)
X4
Fast transient/burst immunity test IEC 61000-4-4:1kV
Withstand voltage 1780VACrms for 3 cycles between all AC external terminals and ground X3
X2
40 20 10 8 4 2 1 4 2 1
Insulation resistance 10MΩ or higher between all AC external terminals and ground (500VDC
STATION NO.
Weight 0.20kg
AJ65SBTB2N-8A
DA DG +24V
connection module power supply part [Transmission circuit, module power supply, FG]
DB
4-1 4-1
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
TB2 DB
1 DA
2 DB TB3 DG
3 DG Insulation TB4 SLD
4 SLD
TB5 +24V
5 +24V
6 FG TB6 (FG)
7 24G TB7 24G
Module power supply
TB8 X0
8 X0 TB9 COM B
9 COM B TB10 X1
10 X1
11 COM B TB11 COM B
12 X2 TB12 X2
13 COM B TB13 COM B
14 X3
15 COM B TB14 X3
16 X4 TB15 COM B
17 COM B TB16 X4
18 X5
19 COM B TB17 COM B
20 X6
21 COM B
TB18 X5 4
TB19 COM B
22 X7
23 COM B TB20 X6
24 COM A TB21 COM B
25 COM B TB22 X7
100VAC
TB23 COM B
TB24 COM A
TB25 COM B
All COM B terminals are connected inside the module (shared common).
4-2 4-2
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB
X8 9 A B C D E F
COMA
Response time OFF→ON 20ms or less (at 100VAC, 60Hz)
XF
ON→OFF 20ms or less (at 100VAC, 60Hz)
XE
Wiring method for common 16 points/common (2-wire, terminal block type)
PW L RUN L ERR. X0 1 2 3 4 5 6 7
XD
Number of occupied stations 32-point assignment/station (16 points used)
XC
Module power supply Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
XB
Current 40mA or lower (at 24VDC and all points ON)
XA
Noise immunity Noise voltage: 1500Vp-p (AC type), 500Vp-p (DC type), noise width 1µs,
X9
noise frequency 25 to 60Hz (noise simulator condition)
X8
Fast transient/burst immunity test IEC61000-4-4:1kV
X7
Withstand voltage 1780VACrms for 3 cycles between all AC external terminals and ground (2000m above
X6
sea level)
X5
500VAC for 1 minute between all DC external terminals and ground
X4
Insulation resistance 10MΩ or higher between all AC external terminals and ground (500VDC insulation
resistance tester)
X3
B RATE
40 20 10 8 4 2 1 4 2 1
10MΩ or higher between all DC external terminals and ground (500VDC insulation
X2
resistance tester)
X1
STATION NO.
Weight 0.25kg
X0
External Communication part, 7-point two-piece terminal block
(FG)
24G
ON
connection module power supply part [Transmission circuit, module power supply, FG]
AJ65SBTB2N-16A
DG +24V
system M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
SLD
Applicable solderless terminal: 2 or less
DB
I/O power supply part, 34-point direct-mount terminal block DA
4-3 4-3
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
TB2 DB
1 DA TB3 DG
2 DB TB4 SLD
3 DG Insulation
TB5 +24V
4 SLD
5 +24V TB6 (FG)
6 FG TB7 24G
7 24G TB8 X0
Module power supply
TB9 COM B
8 X0 TB10 X1
9 COM B TB11 COM B
10 X1 TB12 X2
11 COM B
TB13 COM B
12 X2
13 COM B TB14 X3
14 X3 TB15 COM B
15 COM B TB16 X4
16 X4
TB17 COM B
17 COM B
18 X5 TB18 X5
19 COM B TB19 COM B
20 X6 TB20 X6
21 COM B TB21 COM B
22 X7
TB22 X7
23 COM B
24 X8 TB23 COM B
25 COM B TB24 X8
26 X9 TB25 COM B
27 COM B TB26 X9
28 XA
TB27 COM B
29 COM B
30 XB TB28 XA
31 COM B TB29 COM B
32 XC TB30 XB
33 COM B
TB31 COM B
34 XD
35 COM B
TB32 XC
36 XE TB33 COM B
37 COM B TB34 XD
38 XF TB35 COM B
39 COM B
TB36 XE
40 COM A
41 COM B TB37 COM B
TB38 XF
100VAC
TB39 COM B
TB40 COM A
TB41 COM B
All COM B terminals are connected inside the module (shared common).
4-4 4-4
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
4.1.3 AJ65SBTB1-8D 24VDC input module (positive common (sink), negative common
(source) loading)
Type DC input module
Item AJ65SBTB1-8D Appearance
Number of input points 8 points
Isolation method Photocoupler
Rated input voltage 24VDC
Rated input current Approx. 7mA
Operating voltage range 19.2 to 26.4VDC (ripple ratio: within 5%)
Max. number of simultaneous 100%
input points
ON voltage/ON current 14VDC or higher/3.5mA or higher
OFF voltage/OFF current 6VDC or lower/1.7mA or lower
Input resistance Approx. 3.3kΩ
Response time OFF→ON 1.5ms or less (at 24VDC)
ON→OFF 1.5ms or less (at 24VDC)
COM
COM
Wiring method for common 8 points/common (2 points) (1-wire, terminal block type)
B RATE
40 20 10 8 4 2 1 4 2 1
X7
Input type Positive/negative common shared type (sink/source shared type)
X6
Number of occupied stations 32-point assignment/station (8 points used)
X5
STATION NO.
X4
Module power supply Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
X3
Current 30mA or lower (at 24VDC and all points ON)
X2
Noise immunity Noise voltage 500Vp-p, noise width 1µs,
X1
ON
noise frequency 25 to 60Hz (DC type noise simulator condition)
X0
X0 1 2 3 4 5 6 7
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
Insulation resistance 10MΩ or higher between all DC external terminals and ground (500VDC
A J65SBTB1-8D
24G
(FG)
insulation resistance tester)
Protection degree IP2X
+24V
Weight 0.14kg
SLD
DG
External Communication part, 7-point two-piece terminal block [Transmission circuit, module power supply, FG]
DB
connection module power supply M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
DA
system part Applicable solderless terminal: 2 or less
I/O power supply 10-point direct-mount terminal block [I/O power supply, I/O signal]
part, M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
I/O part Applicable solderless terminal: 2 or less
Module mounting screw M4 screw with plain washer finished round
(tightening torque range: 0.78 to 1.08N•m)
Mountable with a DIN rail in 6 orientations
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
Applicable solderless terminal y RAV1.25-3 (compliant with JIS C 2805)
[Applicable wire size: 0.3 to 1.25mm2]
y V2-MS3, RAP2-3SL, TGV2-3N
2
[Applicable wire size: 1.25 to 2.0mm ]
Accessory User’s manual
External connection
Terminal number Signal name
TB1 DA
1 DA TB2 DB
2 DB TB3 DG
3 DG Insulation TB4 SLD
4 SLD
TB5 +24V
5 +24V
6 FG
TB6 (FG)
7 24G TB7 24G
Module power supply TB8 X0
8 X0 TB9 X1
9 X1 TB10 X2
10 X2 TB11 X3
11 X3
TB12 X4
12 X4
13 X5
TB13 X5
14 X6 TB14 X6
15 X7 TB15 X7
16 COM
TB16 COM
17 COM
TB17 COM
4-5 4-5
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
4.1.4 AJ65SBTB3-8D 24VDC input module (positive common (sink), negative common
(source) loading)
Type DC input module
Item AJ65SBTB3-8D Appearance
Number of input points 8 points
Isolation method Photocoupler
Rated input voltage 24VDC
Rated input current Approx. 7mA
Operating voltage range 19.2 to 26.4VDC (ripple ratio: within 5%)
Max. number of simultaneous input 100%
points
ON voltage/ON current 14VDC or higher/3.5mA or higher
OFF voltage/OFF current 6VDC or lower/1.7mA or lower
DC24A
B RATE
40 20 10 8 4 2 1 4 2 1
Response time OFF→ON 1.5ms or less (at 24VDC)
X7
ON→OFF 1.5ms or less (at 24VDC)
STATION NO.
Wiring method for common 8 points/common (3-wire, terminal block type)
X6
Input type Positive/negative common shared type (sink/source shared type)
Supply current for connected device 1.0A or lower/common
X5
Number of occupied stations 32-point assignment/station (8 points used)
ON
X4
Module power supply Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
Current 40mA or lower (at 24VDC and all points ON)
X3
Noise immunity Noise voltage 500Vp-p, noise width 1µs,
X2
noise frequency 25 to 60Hz (DC type noise simulator condition)
AJ65SBTB3-8D
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
X1
Insulation resistance 10MΩ or higher between all DC external terminals and ground (500VDC
insulation resistance tester)
X0
X0 1 2 3 4 5 6 7
Protection degree IP2X
Weight 0.18kg
(FG)
24G
External Communication part, 7-point two-piece terminal block [Transmission circuit, module power supply, FG]
connection module power supply part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
DA DG +24V
system Applicable solderless terminal: 2 or less
SLD
I/O power supply part, 18-point direct-mount terminal block [I/O power supply, I/O signal]
I/O part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
DB
Applicable solderless terminal: 2 or less
Module mounting screw M4 screw with plain washer finished round
(tightening torque range: 0.78 to 1.08N•m)
Mountable with a DIN rail in 6 orientations
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
Applicable solderless terminal y RAV1.25-3 (compliant with JIS C 2805)
2
[Applicable wire size: 0.3 to 1.25mm ]
y V2-MS3, RAP2-3SL, TGV2-3N
2
[Applicable wire size: 1.25 to 2.0mm ]
Accessory User’s manual
External connection
Terminal number Signal name
TB1 DA
1 DA
TB2 DB
2 DB
TB3 DG
3 DG Insulation
4 SLD
TB4 SLD
5 +24V TB5 +24V
6 FG TB6 (FG)
7 24G TB7 24G
Module power supply TB8 X0
Black TB9 COM A
3-wire sensor 8 X0
Brown TB10 X1
9 COM A
Blue TB11 COM B
10 X1
11 COM B TB12 X2
2-wire sensor Blue
Brown 12 X2 TB13 COM A
13 COM A TB14 X3
14 X3 TB15 COM B
15 COM B TB16 X4
16 X4 TB17 COM A
17 COM A
TB18 X5
18 X5
TB19 COM B
19 COM B
20 X6
TB20 X6
21 COM A TB21 COM A
22 X7 TB22 X7
23 COM B TB23 COM B
24 DC24A TB24 DC24A
25 DC24B TB25 DC24B
4-6 4-6
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
4.1.5 AJ65SBTB1-16D 24VDC input module (positive common (sink), negative common
(source) loading)
Type DC input module
Item AJ65SBTB1-16D Appearance
Number of input points 16 points
Isolation method Photocoupler
Rated input voltage 24VDC
Rated input current Approx. 7mA
Operating voltage range 19.2 to 26.4VDC (ripple ratio: within 5%)
Max. number of simultaneous input 100%
points
ON voltage/ON current 14VDC or higher/3.5mA or higher
COM
OFF voltage/OFF current 6VDC or lower/1.7mA or lower
COM
B RATE
40 20 10 8 4 2 1 4 2 1
Input resistance
XF
Approx. 3.3kΩ
XE
Response time OFF→ON 1.5ms or less (at 24VDC)
XD
STATION NO.
ON→OFF 1.5ms or less (at 24VDC)
XC
Wiring method for common 16 points/common (2 points) (1-wire, terminal block type)
XB
Input type Positive/negative common shared type (sink/source shared type)
XA
Number of occupied stations 32-point assignment/station (16 points used)
X9
ON
Module power supply Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
X8
X7
Current 35mA or lower (at 24VDC and all points ON)
X6
Noise immunity Noise voltage 500Vp-p, noise width 1µs,
X8 9 A B C D E F
X5
noise frequency 25 to 60Hz (DC type noise simulator condition)
X4
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
AJ65SBTB1-16D
X3
Insulation resistance 10MΩ or higher between all DC external terminals and ground (500VDC
X2
insulation resistance tester)
X1
Protection degree IP2X
X0
Weight 0.18kg
X0 1 2 3 4 5 6 7
External Communication part, 7-point two-piece terminal block
connection module power supply [Transmission circuit, module power supply, FG]
(FG)
24G
system part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
Applicable solderless terminal: 2 or less
+24V
I/O power supply part, 18-point direct-mount terminal block [I/O power supply, I/O signal]
SLD
I/O part M3×5.2 screw(tightening torque range: 0.59 to 0.88N•m)
DA DG
Applicable solderless terminal: 2 or less
DB
Module mounting screw M4 screw with plain washer finished round
(tightening torque range: 0.78 to 1.08N•m)
Mountable with a DIN rail in 6 orientations
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
Applicable solderless terminal y RAV1.25-3 (compliant with JIS C 2805)
2
[Applicable wire size: 0.3 to 1.25mm ]
y V2-MS3, RAP2-3SL, TGV2-3N
2
[Applicable wire size: 1.25 to 2.0mm ]
Accessory User’s manual
External connection
Terminal number Signal name
TB1 DA
1 DA TB2 DB
2 DB TB3 DG
3 DG Insulation TB4 SLD
4 SLD
TB5 +24V
5 +24V
TB6 (FG)
6 FG
7 24G
TB7 24G
Module power supply TB8 X0
TB9 X1
8 X0 TB10 X2
9 X1 TB11 X3
10 X2
TB12 X4
11 X3
TB13 X5
12 X4
13 X5
TB14 X6
14 X6 TB15 X7
15 X7 TB16 X8
16 X8 TB17 X9
17 X9 TB18 XA
18 XA TB19 XB
19 XB TB20 XC
20 XC TB21 XD
21 XD
TB22 XE
22 XE
TB23 XF
23 XF
TB24 COM
24 COM
25 COM
TB25 COM
4-7 4-7
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
4.1.6 AJ65SBTB1-16D1 24VDC input module (positive common (sink), negative common
(source) loading)
Type DC input module
Item AJ65SBTB1-16D1 Appearance
Number of input points 16 points
Isolation method Photocoupler
Rated input voltage 24VDC
Rated input current Approx. 5mA
Operating voltage range 19.2 to 26.4VDC (ripple ratio: within 5%)
Max. number of simultaneous input 100%
points
ON voltage/ON current 15VDC or higher/3mA or higher
COM
OFF voltage/OFF current 3VDC or lower/0.5mA or lower
COM
B RATE
40 20 10 8 4 2 1 4 2 1
Input resistance
XF
Approx. 4.7kΩ
XE
Response time OFF→ON 0.2ms or less (at 24VDC)
XD
STATION NO.
ON→OFF 0.2ms or less (at 24VDC)
XC
Wiring method for common 16 points/common (2 points) (1-wire, terminal block type)
XB
Input type Positive/negative common shared type (sink/source shared type)
XA
Number of occupied stations 32-point assignment/station (16 points used)
X9
ON
Module power supply Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
X8
X7
Current 40mA or lower (at 24VDC and all points ON)
X6
Noise immunity Noise voltage 500Vp-p, noise width 1µs,
X8 9 A B C D E F
X5
noise frequency 25 to 60Hz (DC type noise simulator condition)
X4
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
AJ65SBTB1-16D1
X3
Insulation resistance 10MΩ or higher between all DC external terminals and ground (500VDC
X2
insulation resistance tester)
X1
Protection degree IP2X
X0
Weight 0.18kg
X0 1 2 3 4 5 6 7
External Communication part, 7-point two-piece terminal block
connection module power supply [Transmission circuit, module power supply, FG]
(FG)
24G
system part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
Applicable solderless terminal: 2 or less
+24V
I/O power supply part, 18-point direct-mount terminal block [I/O power supply, I/O signal]
SLD
I/O part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
DA DG
Applicable solderless terminal: 2 or less
DB
Module mounting screw M4 screw with plain washer finished round
(tightening torque range: 0.78 to 1.08N•m)
Mountable with a DIN rail in 6 orientations
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
Applicable solderless terminal y RAV1.25-3 (compliant with JIS C 2805)
2
[Applicable wire size: 0.3 to 1.25mm ]
y V2-MS3, RAP2-3SL, TGV2-3N
2
[Applicable wire size: 1.25 to 2.0mm ]
Accessory User’s manual
External connection
Terminal number Signal name
TB1 DA
1 DA
2 DB TB2 DB
3 DG TB3 DG
Insulation
4 SLD TB4 SLD
5 +24V TB5 +24V
6 FG TB6 (FG)
7 24G TB7 24G
Module power supply
TB8 X0
8 X0
TB9 X1
9 X1 TB10 X2
10 X2 TB11 X3
11 X3 TB12 X4
12 X4 TB13 X5
13 X5 TB14 X6
14 X6 TB15 X7
15 X7 TB16 X8
16 X8 TB17 X9
17 X9
TB18 XA
18 XA
TB19 XB
19 XB
20 XC
TB20 XC
21 XD TB21 XD
22 XE TB22 XE
23 XF TB23 XF
24 COM TB24 COM
25 COM TB25 COM
4-8 4-8
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
4.1.7 AJ65SBTB3-16D 24VDC input module (positive common (sink), negative common
(source) loading)
Type DC input module
Item AJ65SBTB3-16D Appearance
Number of input points 16 points
Isolation method Photocoupler
Rated input voltage 24VDC
Rated input current Approx. 7mA
Operating voltage range 19.2 to 26.4VDC (ripple ratio: within 5%)
Max. number of simultaneous input points 100%
ON voltage/ON current 14VDC or higher/3.5mA or higher
OFF voltage/OFF current 6VDC or lower/1.7mA or lower
COMA COMB COMA COMB COMA COMB COMA COMB COMA COMB COMA COMB COMA COMB COMA COMB DC24B
Input resistance Approx. 3.3kΩ
DC24A
B RATE
40 20 10 8 4 2 1 4 2 1
Response time OFF→ON 1.5ms or less (at 24VDC)
XF
STATION NO.
ON→OFF 1.5ms or less (at 24VDC)
XE
Wiring method for common 16points/common (3-wire, terminal block type)
XD
Input type Positive/negative common shared type (sink/source shared type)
ON
XC
Supply current for connected device 1.0A or lower/common
XB
Number of occupied stations 32-point assignment/station (16points used)
XA
Module power supply Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
X9
Current 45mA or lower (at 24VDC and all points ON)
X8
X7
Noise immunity Noise voltage 500Vp-p, noise width 1µs,
X6
noise frequency 25 to 60Hz (DC type noise simulator condition)
X5
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
X4
Insulation resistance 10MΩ or higher between all DC external terminals and ground (500VDC insulation
resistance tester)
X3
X8 9 A B C D E F
X2
Protection degree IP2X
AJ65SBTB3-16D
X1
Weight 0.25kg
X0
External Communication part, 7-point two-piece terminal block [Transmission circuit, module power supply, FG]
PW L RUN L ERR. X0 1 2 3 4 5 6 7
connection module power supply part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
(FG)
24G
system Applicable solderless terminal: 2 or less
+24V
I/O power supply part, 34-point direct-mount terminal block [I/O power supply, I/O signal]
SLD
DG
I/O part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
DB
DA
Applicable solderless terminal: 2 or less
Module mounting screw M4 screw with plain washer finished round (tightening torque range: 0.78 to 1.08N•m)
Mountable with a DIN rail in 6 orientations
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
Applicable solderless terminal y RAV1.25-3 (compliant with JIS C 2805)
[Applicable wire size: 0.3 to 1.25mm2]
y V2-MS3, RAP2-3SL, TGV2-3N
[Applicable wire size: 1.25 to 2.0mm2]
Accessory User’s manual
4-9 4-9
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
TB2 DB
1 DA TB3 DG
2 DB TB4 SLD
3 DG Insulation TB5 +24V
4 SLD
5 +24V
TB6 (FG)
6 FG TB7 24G
7 24G TB8 X0
Module power supply
TB9 COM A
Black TB10 X1
3-wire sensor 8 X0
Brown
9 COM A TB11 COM B
Blue
10 X1 TB12 X2
Blue 11 COM B
2-wire sensor TB13 COM A
Brown 12 X2
13 COM A
TB14 X3
14 X3 TB15 COM B
15 COM B TB16 X4
16 X4 TB17 COM A
17 COM A
TB18 X5
18 X5
19 COM B TB19 COM B
20 X6 TB20 X6
21 COM A TB21 COM A
22 X7 TB22 X7
23 COM B
24 X8
TB23 COM B
25 COM A TB24 X8
26 X9 TB25 COM A
27 COM B TB26 X9
28 XA
TB27 COM B
29 COM A
30 XB TB28 XA
31 COM B TB29 COM A
32 XC TB30 XB
33 COM A TB31 COM B
34 XD
TB32 XC
35 COM B
36 XE TB33 COM A
37 COM A TB34 XD
38 XF TB35 COM B
39 COM B TB36 XE
40 DC24A
TB37 COM A
41 DC24B
TB38 XF
TB39 COM B
TB40 DC24A
TB41 DC24B
4 - 10 4 - 10
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
4.1.8 AJ65SBTB3-16KD 24VDC input module (positive common (sink), negative common
(source) loading)
4 - 11 4 - 11
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
TB2 DB
1 DA TB3 DG
2 DB
TB4 SLD
3 DG Insulation
4 SLD TB5 +24V
5 +24V TB6 (FG)
6 FG TB7 24G
7 24G
Module power supply TB8 X0
TB9 COM A
TB10 X1
Black TB11 COM B
3-wire sensor 8 X0
Brown
9 COM A TB12 X2
Blue
10 X1
TB13 COM A
Blue 11 COM B
2-wire sensor TB14 X3
Brown 12 X2
13 COM A TB15 COM B
14 X3 TB16 X4
15 COM B
TB17 COM A
16 X4
17 COM A
TB18 X5
18 X5 TB19 COM B
19 COM B TB20 X6
20 X6 TB21 COM A
21 COM A
22 X7
TB22 X7
23 COM B TB23 COM B
24 X8 TB24 X8
25 COM A
TB25 COM A
26 X9
TB26 X9
27 COM B
28 XA TB27 COM B
29 COM A TB28 XA
30 XB TB29 COM A
31 COM B
TB30 XB
32 XC
33 COM A TB31 COM B
34 XD TB32 XC
35 COM B
TB33 COM A
36 XE
TB34 XD
37 COM A
38 XF TB35 COM B
39 COM B TB36 XE
40 DC24A TB37 COM A
41 DC24B
TB38 XF
TB39 COM B
TB40 DC24A
TB41 DC24B
4 - 12 4 - 12
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
4.1.9 AJ65SBTB3-16D5 5VDC input module (positive common (sink), negative common
(source) loading)
Type DC input module
Item AJ65SBTB3-16D5 Appearance
Number of input points 16 points
Isolation method Photocoupler
Rated input voltage 5VDC
Rated input current Approx. 4mA
Operating voltage range 4.25 to 6VDC (ripple ratio: within 5%)
Max. number of simultaneous input 100%
points
ON voltage/ON current 3.5VDC or higher/2mA or higher
OFF voltage/OFF current 1.5VDC or lower/1mA or lower
STATI ON NO.
Input resistance Approx. 1.0kΩ
Response time OFF→ON 1.5ms or less (at 5VDC)
ON→OFF 1.5ms or less (at 5VDC)
Wiring method for common 16 points/common (3-wire, terminal block type)
Input type Positive/negative common shared type (sink/source shared type)
Supply current for connected device 1.0A or lower/common
Number of occupied stations 32-point assignment/station (16 points used)
Module power supply Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
Current 30mA or lower (at 24VDC and all points ON)
Noise immunity Noise voltage 500Vp-p, noise width 1µs,
noise frequency 25 to 60Hz (DC type noise simulator condition)
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
Insulation resistance 10MΩ or higher between all DC external terminals and ground (500VDC insulation
resistance tester)
Protection degree IP2X
Weight 0.25kg
External Communication part, 7-point two-piece terminal block [Transmission circuit, module power supply, FG]
connection module power supply part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
A
system Applicable solderless terminal: 2 or less
I/O power supply part, 34-point direct-mount terminal block [I/O power supply, I/O signal]
I/O part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
Applicable solderless terminal: 2 or less
Module mounting screw M4 screw with plain washer finished round (tightening torque range: 0.78 to 1.08N•m)
Mountable with a DIN rail in 6 orientations
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
Applicable solderless terminal y RAV1.25-3 (compliant with JIS C 2805)
[Applicable wire size: 0.3 to 1.25mm2]
y V2-MS3, RAP2-3SL, TGV2-3N
[Applicable wire size: 1.25 to 2.0mm2]
Accessory User’s manual
4 - 13 4 - 13
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
1 DA
2 DB TB2 DB
3 DG Insulation TB3 DG
4 SLD TB4 SLD
5 +24V
6 FG
TB5 +24V
7 24G TB6 (FG)
Module power supply TB7 24G
TB8 X0
TB9 COM A
TTL, LS-TTL, or CMOS buffer 8 X0
9 COM A TB10 X1
10 X1 TB11 COM B
11 COM B TB12 X2
Open collector 12 X2
TB13 COM A
13 COM A
14 X3 TB14 X3
15 COM B TB15 COM B
16 X4
TB16 X4
17 COM A
18 X5 TB17 COM A
19 COM B TB18 X5
20 X6 TB19 COM B
21 COM A
22 X7
TB20 X6
23 COM B TB21 COM A
24 X8 TB22 X7
25 COM A
TB23 COM B
26 X9
27 COM B TB24 X8
28 XA TB25 COM A
29 COM A
TB26 X9
30 XB
31 COM B
TB27 COM B
32 XC TB28 XA
33 COM A TB29 COM A
34 XD
TB30 XB
35 COM B
36 XE TB31 COM B
37 COM A TB32 XC
TTL, LS-TTL, or CMOS buffer 38 XF
TB33 COM A
39 COM B
1 TB34 XD
40 DC5A
41 DC5B TB35 COM B
TB36 XE
TB37 COM A
TB38 XF
TB39 COM B
TB40 DC5A
TB41 DC5B
2
For TTL, LS-TTL, or CMOS buffer (positive common) connection For a sensor (negative common) connection
COM B
COM A
X0 X0
COM B
COM A
Detection circuit
1: Polarity to connect an external power supply for TTL, LS-TTL, and CMOS buffer (positive common) connection.
For a sensor (negative common) connection, connect the negative pole to DC5A and the positive pole to DC5B.
2: For connection of TTL output (source type) sensor, use a sensor with a built-in pull-up resistor or provide a pull-up resistor in the circuit.
4 - 14 4 - 14
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
4.1.10 AJ65SBTB1-32D 24VDC input module (positive common (sink), negative common
(source) loading)
Type DC input module
Item AJ65SBTB1-32D Appearance
Number of input points 32 points
Isolation method Photocoupler
Rated input voltage 24VDC
Rated input current Approx. 7mA
Operating voltage range 19.2 to 26.4VDC (ripple ratio: within 5%)
Max. number of simultaneous input 100%
points
X1F COM
ON voltage/ON current 14VDC or higher/3.5mA or higher
X1E COM
B RATE
40 20 10 8 4 2 1 4 2 1
OFF voltage/OFF current 6VDC or lower/1.7mA or lower
X1D
STATION NO.
Input resistance Approx. 3.3kΩ
X1C
X1B
Response time OFF→ON 1.5ms or less (at 24VDC)
X1A
X19
ON→OFF 1.5ms or less (at 24VDC)
X18
ON
Wiring method for common 32 points/common (2 points) (1-wire, terminal block type)
X17
X16
Input type Positive/negative common shared type (sink/source shared type)
X15
X14
Number of occupied stations 32-point assignment/station (32 points used)
X13
X12
Module power supply Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
X11
Current 45mA or lower (at 24VDC and all points ON)
X10
XF
Noise immunity Noise voltage 500Vp-p, noise width 1µs,
XE
XD
noise frequency 25 to 60Hz (DC type noise simulator condition)
XC
XB
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
XA
Insulation resistance 10MΩ or higher between all DC external terminals and ground (500VDC insulation
X9
X8
resistance tester)
X7
X6
Protection degree IP2X
X8 9 A B C D E F
X5
Weight 0.25kg
X4
AJ65SBTB1-32D
X3
External Communication part, 7-point two-piece terminal block [Transmission circuit, module power supply, FG]
X2
X1
connection module power supply part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
X0
PW L RUN L ERR. X0 1 2 3 4 5 6 7
system Applicable solderless terminal: 2 or less
I/O power supply part, 34-point direct-mount terminal block [I/O power supply, I/O signal]
(FG)
24G
I/O part M3×5.2 screw(tightening torque range: 0.59 to 0.88N•m)
DA DG +24V
DB SLD
Applicable solderless terminal: 2 or less
Module mounting screw M4 screw with plain washer finished round
(tightening torque range: 0.78 to 1.08N•m)
Mountable with a DIN rail in 6 orientations
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
Applicable solderless terminal y RAV1.25-3 (compliant with JIS C 2805)
[Applicable wire size: 0.3 to 1.25mm2]
y V2-MS3, RAP2-3SL, TGV2-3N
[Applicable wire size: 1.25 to 2.0mm2]
Accessory User’s manual
4 - 15 4 - 15
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
TB2 DB
TB3 DG
1 DA
TB4 SLD
2 DB
3 DG Insulation TB5 +24V
4 SLD TB6 (FG)
5 +24V TB7 24G
6 FG TB8 X0
7 24G
Module power supply TB9 X1
8 X0 TB10 X2
9 X1 TB11 X3
10 X2 TB12 X4
11 X3
TB13 X5
12 X4
13 X5
TB14 X6
14 X6 TB15 X7
15 X7 TB16 X8
16 X8 TB17 X9
17 X9
TB18 XA
18 XA
19 XB TB19 XB
20 XC TB20 XC
21 XD TB21 XD
22 XE
TB22 XE
23 XF
24 X10 TB23 XF
25 X11 TB24 X10
26 X12 TB25 X11
27 X13 TB26 X12
28 X14
29 X15
TB27 X13
30 X16 TB28 X14
31 X17 TB29 X15
32 X18 TB30 X16
33 X19
TB31 X17
34 X1A
35 X1B TB32 X18
36 X1C TB33 X19
37 X1D TB34 X1A
38 X1E
TB35 X1B
39 X1F
40 COM
TB36 X1C
41 COM TB37 X1D
TB38 X1E
TB39 X1F
TB40 COM
TB41 COM
4 - 16 4 - 16
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
4.1.11 AJ65SBTB1-32KD 24VDC input module (positive common (sink), negative common
(source) loading)
Type DC input module
Item AJ65SBTB1-32KD Appearance
Number of input points 32 points
Isolation method Photocoupler
Rated input voltage 24VDC
Rated input current Approx. 7mA
Operating voltage range 20.4 to 28.8VDC (ripple ratio: within 5%)
Max. number of simultaneous input 100% (at 26.4VDC), 50% (at 28.8VDC)
points
ON voltage/ON current 14VDC or higher/4mA or higher
OFF voltage/OFF current 5.5VDC or lower/1.7mA or lower
Input resistance Approx. 3.0kΩ
Input response
0.2ms 1.5ms 5ms 10ms
speed
Response time
OFF→ON 0.2ms or less 1.5ms or less 5ms or less 10ms or less
ON→OFF 0.2ms or less 1.5ms or less 5ms or less 10ms or less
Wiring method for common 32 points/common (1-wire, terminal block type)
Input type Positive/negative common shared type (sink/source shared type)
Number of occupied stations 32-point assignment/station (32 points used)
Module power supply Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
Current 75mA or lower (at 24VDC and all points ON)
Noise immunity Noise voltage 500Vp-p, noise width 1µs,
noise frequency 25 to 60Hz (DC type noise simulator condition)
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
Insulation resistance 10MΩ or higher between all DC external terminals and ground (500VDC insulation
resistance tester)
Protection degree IP2X
Weight 0.26kg
External Communication part, 7-point two-piece terminal block [Transmission circuit, module power supply, FG]
connection module power supply part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
system Applicable solderless terminal: 2 or less
I/O power supply part, 34-point direct-mount terminal block [I/O power supply, I/O signal]
I/O part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
Applicable solderless terminal: 2 or less
Module mounting screw M4 screw with plain washer finished round
(tightening torque range: 0.78 to 1.08N•m)
Mountable with a DIN rail in 6 orientations
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
Applicable solderless terminal y RAV1.25-3 (compliant with JIS C 2805)
2
[Applicable wire size: 0.3 to 1.25mm ]
y V2-MS3, RAP2-3SL, TGV2-3N
[Applicable wire size: 1.25 to 2.0mm2]
Accessory User’s manual
4 - 17 4 - 17
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
TB2 DB
TB3 DG
1 DA
2 DB TB4 SLD
3 DG Insulation TB5 +24V
4 SLD TB6 (FG)
5 +24V
TB7 24G
6 FG
7 24G TB8 X0
Module power supply TB9 X1
TB10 X2
TB11 X3
8 X0
TB12 X4
9 X1
10 X2
TB13 X5
11 X3 TB14 X6
12 X4 TB15 X7
13 X5
TB16 X8
14 X6
15 X7 TB17 X9
16 X8 TB18 XA
17 X9 TB19 XB
18 XA
TB20 XC
19 XB
20 XC TB21 XD
21 XD TB22 XE
22 XE TB23 XF
23 XF
TB24 X10
24 X10
25 X11 TB25 X11
26 X12 TB26 X12
27 X13 TB27 X13
28 X14
TB28 X14
29 X15
30 X16 TB29 X15
31 X17 TB30 X16
32 X18 TB31 X17
33 X19
TB32 X18
34 X1A
35 X1B TB33 X19
36 X1C TB34 X1A
37 X1D TB35 X1B
38 X1E
TB36 X1C
39 X1F
40 COM TB37 X1D
41 COM TB38 X1E
TB39 X1F
TB40 COM
TB41 COM
4 - 18 4 - 18
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
4.1.12 AJ65SBTB1-32D1 24VDC input module (positive common (sink), negative common
(source) loading)
Type DC input module
Item AJ65SBTB1-32D1 Appearance
Number of input points 32 points
Isolation method Photocoupler
Rated input voltage 24VDC
Rated input current Approx. 5mA
Operating voltage range 19.2 to 26.4VDC (ripple ratio: within 5%)
Max. number of simultaneous input 100%
points
X1F COM
ON voltage/ON current 15VDC or higher/3mA or higher
X1E COM
B RATE
40 20 10 8 4 2 1 4 2 1
OFF voltage/OFF current 3VDC or lower/0.5mA or lower
X1D
STATION NO.
Input resistance Approx. 4.7kΩ
X1C
X1B
Response time OFF→ON 0.2ms or less (at 24VDC)
X1A
X19
ON→OFF 0.2ms or less (at 24VDC)
X18
ON
Wiring method for common 32 points/common (2 points) (1-wire, terminal block type)
X17
X16
Input type Positive/negative common shared type (sink/source shared type)
X15
X14
Number of occupied stations 32-point assignment/station (32 points used)
X13
X12
Module power supply Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
X11
Current 50mA or lower (at 24VDC and all points ON)
X10
XF
Noise immunity Noise voltage 500Vp-p, noise width 1µs,
XE
XD
noise frequency 25 to 60Hz (DC type noise simulator condition)
XC
XB
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
XA
Insulation resistance 10MΩ or higher between all DC external terminals and ground (500VDC
X9
X8
insulation resistance tester)
X7
X6
Protection degree IP2X
X8 9 A B C D E F
X5
Weight 0.25kg
X4
AJ65SBTB1-32D1
X3
External Communication part, 7-point two-piece terminal block [Transmission circuit, module power supply, FG]
X2
X1
connection module power supply part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
X0
PW L RUN L ERR. X0 1 2 3 4 5 6 7
system Applicable solderless terminal: 2 or less
I/O power supply part, 34-point direct-mount terminal block [I/O power supply, I/O signal]
(FG)
24G
I/O part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
DA DG +24V
DB SLD
Applicable solderless terminal: 2 or less
Module mounting screw M4 screw with plain washer finished round
(tightening torque range: 0.78 to 1.08N•m)
Mountable with a DIN rail in 6 orientations
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
Applicable solderless terminal y RAV1.25-3 (compliant with JIS C 2805)
[Applicable wire size: 0.3 to 1.25mm2]
y V2-MS3, RAP2-3SL, TGV2-3N
[Applicable wire size: 1.25 to 2.0mm2]
Accessory User’s manual
4 - 19 4 - 19
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
TB2 DB
1 DA
TB3 DG
2 DB
3 DG TB4 SLD
Insulation
4 SLD TB5 +24V
5 +24V TB6 (FG)
6 FG TB7 24G
7 24G TB8 X0
Module power supply
TB9 X1
8 X0 TB10 X2
9 X1 TB11 X3
10 X2 TB12 X4
11 X3
TB13 X5
12 X4
13 X5 TB14 X6
14 X6 TB15 X7
15 X7 TB16 X8
16 X8 TB17 X9
17 X9 TB18 XA
18 XA
TB19 XB
19 XB
20 XC TB20 XC
21 XD TB21 XD
22 XE TB22 XE
23 XF TB23 XF
24 X10 TB24 X10
25 X11
TB25 X11
26 X12
27 X13 TB26 X12
28 X14 TB27 X13
29 X15 TB28 X14
30 X16 TB29 X15
31 X17 TB30 X16
32 X18
TB31 X17
33 X19
34 X1A TB32 X18
35 X1B TB33 X19
36 X1C TB34 X1A
37 X1D TB35 X1B
38 X1E TB36 X1C
39 X1F
TB37 X1D
40 COM
41 COM TB38 X1E
TB39 X1F
TB40 COM
TB41 COM
4 - 20 4 - 20
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
4.1.13 AJ65SBTB1-32D5 5VDC input module (positive common (sink), negative common
(source) loading)
Type DC input module
Item AJ65SBTB1-32D5 Appearance
Number of input points 32 points
Isolation method Photocoupler
Rated input voltage 5VDC
Rated input current Approx. 4mA
Operating voltage range 4.25 to 6VDC (ripple ratio: within 5%)
Max. number of simultaneous input 100%
points
ON voltage/ON current 3.5VDC or higher/2mA or higher
OFF voltage/OFF current 1.5VDC or lower/1mA or lower
Input resistance Approx. 1.0kΩ
Response time OFF→ON 1.5ms or less (at 5VDC)
ON→OFF 1.5ms or less (at 5VDC)
Wiring method for common 32 points/common (1-wire, terminal block type)
Input type Positive/negative common shared type (sink/source shared type)
Number of occupied stations 32-point assignment/station (32 points used)
Module power supply Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
Current 35mA or lower (at 24VDC and all points ON)
Noise immunity Noise voltage 500Vp-p, noise width 1µs,
noise frequency 25 to 60Hz (DC type noise simulator condition)
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
Insulation resistance 10MΩ or higher between all DC external terminals and ground (500VDC
insulation resistance tester)
Protection degree IP2X
Weight 0.26kg
External Communication part, 7-point two-piece terminal block
connection module power supply part [Transmission circuit, module power supply, FG]
system M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
Applicable solderless terminal: 2 or less
I/O power supply part, 34-point direct-mount terminal block [I/O power supply, I/O signal]
I/O part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
Applicable solderless terminal: 2 or less
Module mounting screw M4 screw with plain washer finished round
(tightening torque range: 0.78 to 1.08N•m)
Mountable with a DIN rail in 6 orientations
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
Applicable solderless terminal y RAV1.25-3 (compliant with JIS C 2805)
[Applicable wire size: 0.3 to 1.25mm2]
y V2-MS3, RAP2-3SL, TGV2-3N
[Applicable wire size: 1.25 to 2.0mm2]
Accessory User’s manual
4 - 21 4 - 21
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
1 DA
2 DB TB2 DB
3 DG Insulation TB3 DG
4 SLD TB4 SLD
5 +24V
TB5 +24V
6 FG
7 24G TB6 (FG)
Module power supply TB7 24G
TB8 X0
TB9 X1
8 X0
Open collector (positive common) 9 X1 TB10 X2
10 X2 TB11 X3
11 X3
TB12 X4
12 X4
13 X5 TB13 X5
14 X6 TB14 X6
15 X7
TB15 X7
16 X8
17 X9 TB16 X8
18 XA TB17 X9
19 XB TB18 XA
20 XC
21 XD TB19 XB
22 XE TB20 XC
23 XF TB21 XD
24 X10
TB22 XE
25 X11
26 X12 TB23 XF
27 X13 TB24 X10
28 X14
TB25 X11
29 X15
30 X16 TB26 X12
31 X17 TB27 X13
32 X18
TB28 X14
33 X19
34 X1A TB29 X15
35 X1B TB30 X16
36 X1C TB31 X17
37 X1D
38 X1E TB32 X18
39 X1F TB33 X19
40 COM TB34 X1A
*1 41 COM
TB35 X1B
TB36 X1C
TB37 X1D
TB38 X1E
TB39 X1F
TB40 COM
TB41 COM
2
For TTL, LS-TTL, or CMOS buffer (positive common) connection For a sensor (negative common) connection
X0 X0
COM
COM
Detection circuit
1: Polarity to connect an external power supply for TTL, LS-TTL, and CMOS buffer (positive common) connection.
For a sensor (negative common) connection, connect the negative pole to COM.
2: For connection of TTL output (source type) sensor, use a sensor with a built-in pull-up resistor or provide a pull-up resistor in the circuit.
4 - 22 4 - 22
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
4.1.14 AJ65DBTB1-32D 24VDC input module (positive common (sink), negative common
(source) loading)
Type DC input module
Item AJ65DBTB1-32D Appearance
Number of input points 32 points
Isolation method Photocoupler
Rated input voltage 24VDC
Rated input current Approx. 5mA
Operating voltage range 20.4 to 31.2VDC (ripple ratio: within 5%)
Max. number of simultaneous input 100% (at 26.4VDC)
points
ON voltage/ON current 15VDC or higher/3mA or higher
OFF voltage/OFF current 5VDC or lower/1.5mA or lower
Input resistance Approx. 4.7kΩ
Response time OFF→ON 10ms or less (at 24VDC)
ON→OFF 10ms or less (at 24VDC)
Wiring method for common 16 points/common (2 points) (1-wire, terminal block type)
Input type Positive/negative common shared type (sink/source shared type)
Number of occupied stations 32-point assignment/station (32 points used)
Module power Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
supply Current 45mA or lower (at 24VDC and all points ON)
Noise immunity Noise voltage 500Vp-p, noise width 1µs,
noise frequency 25 to 60Hz (DC type noise simulator condition)
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
Insulation resistance 10MΩ or higher between all DC external terminals and ground (500VDC
insulation resistance tester)
Protection degree IP2X
Weight 0.6kg
External connection system 50-point terminal block
[Transmission circuit, module power supply, FG, I/O power supply, I/O signal]
M3.5×7 screw (tightening torque range: 0.68 to 0.92N•m)
Applicable solderless terminal: 2 or less
Module mounting screw M4 screw with plain washer finished round
(tightening torque range: 0.78 to 1.08N•m)
Applicable solderless terminal R1.25-3.5, RAV2-3.5 (compliant with JIS C 2805)
Accessory User’s manual
Part sold separately A6DIN1C, A2CCOM-TB
4 - 23 4 - 23
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
Terminal Signal Terminal Signal
number name number name
TB1 DA TB26 Empty
TB2 DG TB27 Empty
TB3 DB TB28 +24V
Insulation
1 Empty 26
TB4 Empty DA TB29 Empty
2 DG Empty 27
TB5 SLD 3 DB +24V 28
24VDC
TB30 (FG)
4 Empty Empty 29
TB6 Empty 5 SLD FG 30
TB31 Empty
TB7 24G 6 Empty Empty 31 TB32 24G
7 24G 24G 32
TB8 X0 TB33 X10
Module power supply
TB9 X1 TB34 X11
8 X0 X10 33
TB10 X2 9 X1 X11 34
TB35 X12
TB11 X3 10 X2 X12 35 TB36 X13
11 X3 X13 36
TB12 X4 12 X4 X14 37 TB37 X14
TB13 X5 13 X5 X15 38 TB38 X15
14 X6 X16 39
TB14 X6 15 X7 X17 40 TB39 X16
16 COM1 COM3 41
TB15 X7 X18 42
TB40 X17
17 X8
TB16 COM1 18 X9 X19 43 TB41 COM3
19 XA X1A 44
TB17 X8 20 XB X1B 45 TB42 X18
TB18 X9 21 XC X1C 46 TB43 X19
22 XD X1D 47
TB19 XA 23 XE X1E 48 TB44 X1A
24 XF X1F 49
TB20 XB COM4 50
TB45 X1B
25 COM2
TB21 XC TB46 X1C
24VDC 24VDC
TB22 XD TB47 X1D
TB23 XE TB48 X1E
TB24 XF TB49 X1F
TB25 COM2 TB50 COM4
4 - 24 4 - 24
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
XF
Supply current for connected 1.0A or lower/common
XD XE
device
Number of occupied stations 32-point assignment/station (16points used)
XA XB XC
Module Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
power supply Current 35mA or lower (at 24VDC and all points ON)
Noise immunity Noise voltage 500Vp-p, noise width 1µs,
X9
noise frequency 25 to 60Hz (DC type noise simulator condition)
COM+
X8
COM-
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
AJ65VBTS3-16D
X7
Insulation resistance 10MΩ or higher between all DC external terminals and ground (500VDC insulation
X6
resistance tester)
X5
Protection degree IP1XB
X4
Weight 0.24kg
X2 X3
External Communication One-touch connector for communication [Transmission circuit] X1
connection part 5-pin IDC plug is sold separately: A6CON-L5P
X0
system <Optional>
COM+
COM-
Online connector for communication: A6CON-LJ5P
NC
Power supply One-touch connector for power supply and FG [Module power supply, FG]
part 5-pin IDC plug is sold separately: A6CON-PW5P, A6CON-PW5P-SOD
D
8 9 A B C DE F
0 1 2 3 4 5 6 7
<Optional>
L RUN L ERR.
I/O part 2-piece spring clamp terminal block [I/O power supply, I/O signals]
ONPW
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715) B RATE STATION NO.
1 2 4 1 2 4 8 1020 40
4 - 25 4 - 25
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
Pin layout
4 - 26 4 - 26
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
1: Attach an unwired connector plug to an unused one-touch connector for power supply and FG.
4 - 27 4 - 27
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
NC X10 X11 X12 X13 X14 X15 X16 X17 X18 X19 X1A X1B X1C X1D X1E X1F
Response OFF→ON 1.5ms or less (at 24VDC)
time ON→OFF 1.5ms or less (at 24VDC)
Wiring method for common 16 points/common (3-wire, spring clamp terminal block type)
Input type Positive common (sink type)
Supply current for connected 2.0A or lower/common
COM2-
COM2+
device
Number of occupied stations 32-point assignment/station (32 points used)
Module Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
power supply Current 40mA or lower (at 24VDC and all points ON)
Noise immunity Noise voltage 500Vp-p, noise width 1µs,
noise frequency 25 to 60Hz (DC type noise simulator condition)
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
AJ65VBTS3-32D
COM2+
COM2-
Insulation resistance 10MΩ or higher between all DC external terminals and ground (500VDC insulation
X9 XA XB XC XD XE XF
resistance tester)
Protection degree IP1XB
Weight 0.41kg
External Communication One-touch connector for communication [Transmission circuit]
connection part 5-pin IDC plug is sold separately: A6CON-L5P
COM1+
COM1-
system <Optional>
X8
X7
Online connector for communication: A6CON-LJ5P X6
Power supply One-touch connector for power supply and FG [Module power supply, FG]
X5
<Optional>
X3
X2
I/O part 2-piece spring clamp terminal block [I/O power supply, I/O signals]
X0
COM1+
COM1-
B RATESTATION NO.
1 2 4 1 2 4 8 102040
4 - 28 4 - 28
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
CONA
1
LINK CABLE 2
1 DA Pin number Signal name
2 DB
(IN) 3
4
3 DG 1 DA
4 Empty
5
5 SLD 2 DB
CONB
1
1 DA CON A, B 3 DG
LINK CABLE 2
2 DB
(OUT) 3
4
3 DG 4 Empty
4 Empty
5
5 SLD 5 SLD
One-touch connector for communication
CONC Insulation
1 (FG)
1
UNIT POWER CABLE(IN)
2
1
2
FG
+24V(UNIT)
2 +24V (UNIT)
3
4
3
4
24G(UNIT)
Empty
CON C, D 3 24G (UNIT)
5
5 Empty
4 Empty
COND
1
UNIT POWER CABLE(OUT)
2
1 FG 5 Empty
2 +24V(UNIT)
3
4
3 24G(UNIT) Terminal block
4 Empty
5
1
5 Empty Column A Column B Column C
One-touch connector for power supply and FG
1 Empty 1 COM1+ 1 COM1-
TB1A Empty
TB1B COM1+ 2 X0 2 COM1+ 2 COM1-
TB1C COM1-
Black
TB2A X0 3 X1 3 COM1+ 3 COM1-
Brown
Blue
TB2B
TB2C
COM1+
COM1-
4 X2 4 COM1+ 4 COM1-
3-wire sensor Brown
(sink output)
Detection
circuit
TB3A
TB3B
X1
COM1+
5 X3 5 COM1+ 5 COM1-
Blue
TB3C COM1- 6 X4 6 COM1+ 6 COM1-
TB4A X2
TB4B COM1+ 7 X5 7 COM1+ 7 COM1-
TB4C COM1-
TB5A X3 8 X6 8 COM1+ 8 COM1-
2-wire sensor Detection
(sink output) circuit
TB5B
TB5C
COM1+
COM1-
9 X7 9 COM1+ 9 COM1-
TB6A
TB6B
X4
COM1+
10 X8 10 COM1+ 10 COM1-
TB6C COM1- 11 X9 11 COM1+ 11 COM1-
TB7A X5
TB7B COM1+ 12 XA 12 COM1+ 12 COM1-
TB7C COM1-
TB8A X6 13 XB 13 COM1+ 13 COM1-
TB8B
TB8C
COM1+
COM1-
14 XC 14 COM1+ 14 COM1-
TB9A X7 15 XD 15 COM1+ 15 COM1-
TB9B COM1+
TB9C COM1- 16 XE 16 COM1+ 16 COM1-
TB10A X8
TB10B COM1+ 17 XF 17 COM1+ 17 COM1-
TB10C
TB11A
COM1-
X9 18 Empty 18 COM2+ 18 COM2-
TB11B
TB11C
COM1+
COM1-
19 X10 19 COM2+ 19 COM2-
TB12A XA 20 X11 20 COM2+ 20 COM2-
TB12B COM1+
TB12C COM1- 21 X12 21 COM2+ 21 COM2-
TB13A XB
TB13B COM1+ 22 X13 22 COM2+ 22 COM2-
TB13C
TB14A
COM1-
XC
23 X14 23 COM2+ 23 COM2-
TB14B
TB14C
COM1+
COM1-
24 X15 24 COM2+ 24 COM2-
TB15A XD 25 X16 25 COM2+ 25 COM2-
TB15B COM1+
TB15C COM1- 26 X17 26 COM2+ 26 COM2-
TB16A XE
TB16B COM1+ 27 X18 27 COM2+ 27 COM2-
TB16C
TB17A
COM1-
XF
28 X19 28 COM2+ 28 COM2-
TB17B
TB17C
COM1+
COM1-
29 X1A 29 COM2+ 29 COM2-
TB18A Empty 30 X1B 30 COM2+ 30 COM2-
TB18B COM2+
Black
TB18C COM2- 31 X1C 31 COM2+ 31 COM2-
TB19A X10
Brown
TB19B COM2+ 32 X1D 32 COM2+ 32 COM2-
Blue
3-wire sensor Detection Brown
TB19C
TB20A
COM2-
X11
33 X1E 33 COM2+ 33 COM2-
(sink output) circuit
Blue
TB20B COM2+ 34 X1F 34 COM2+ 34 COM2-
TB20C COM2-
TB21A X12
TB21B COM2+
TB21C COM2-
TB22A X13
2-wire sensor Detection TB22B COM2+
(sink output) circuit TB22C COM2-
TB23A X14
TB23B COM2+
TB23C COM2-
TB24A X15
TB24B COM2+
TB24C COM2-
TB25A X16
TB25B COM2+
TB25C COM2-
TB26A X17
TB26B COM2+
TB26C COM2-
TB27A X18
TB27B COM2+
TB27C COM2-
TB28A X19
TB28B COM2+
TB28C COM2-
TB29A X1A
TB29B COM2+
TB29C COM2-
TB30A X1B
TB30B COM2+
TB30C COM2-
TB31A X1C
TB31B COM2+
TB31C COM2-
TB32A X1D
TB32B COM2+
TB32C COM2-
TB33A X1E
TB33B COM2+
TB33C COM2-
TB34A X1F
TB34B COM2+
TB34C COM2-
1: Attach an unwired connector plug to an unused one-touch connector for power supply and FG.
4 - 29 4 - 29
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
1: Attach an unwired connector plug to an unused one-touch connector for power supply and FG.
Pin layout
4 - 30 4 - 30
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
40 S
supply Current 30mA or lower (at 24VDC and all points ON) 20
T
A
C 10 T
I
8
Noise immunity Noise voltage 500Vp-p, noise width 1µs, 4
O
N
2
noise frequency 25 to 60Hz (DC type noise simulator condition) 1
N
O.
D 4 B
R
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground 2
1
A
T
E
Insulation resistance 10MΩ or higher between all DC external terminals and ground (500VDC insulation AJ65VBTCE3-8D
PW
resistance tester) X0 L RUN
Protection degree IP1XB L ERR.
X1
Weight 0.10kg 0
1
X2
External Communication One-touch connector for communication [Transmission circuit] 2
3
connection part 5-pin IDC plug is sold separately: A6CON-L5P X3 4
5
system <Optional> 6
X4 7
Online connector for communication: A6CON-LJ5P
X5
Power supply One-touch connector for power supply and FG
part [Module power supply, I/O power supply, FG] X6
5-pin IDC plug is sold separately: A6CON-PW5P, A6CON-PW5P-SOD
X7
<Optional>
Online connector for power supply: A6CON-PWJ5P
I/O part Sensor connector (e-CON) [I/O signals]
1
4-pin IDC plug is sold separately.
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
Applicable Connector for Applicable cable:
wire size communication FANC-110SBH, FA-CBL200PSBH, CS-110
Connector for 0.66 to 0.98mm2 (AWG18)
power supply and [φ2.2 to 3.0mm (A6CON-PW5P),
FG φ2.0 to 2.3mm (A6CON-PW5P-SOD)]
Wire diameter: 0.16mm or more
Insulating coating material: PVC (heat-resistant)
Connector for I/O Sensor connector (e-CON).
Applicable connector plugs are sold separately. 1
2
(applicable wire size: 0.08 to 0.5mm , depending on the connector plug)
Accessory User’s manual, Holding fixtures for screw installation
4 - 31 4 - 31
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
1: Attach an unwired connector plug to an unused one-touch connector for power supply and FG.
2: Wiring the sensor connector (e-CON) incorrectly may cause malfunction or failure due to short circuit of the power supply.
4 - 32 4 - 32
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
1: Attach an unwired connector plug to an unused one-touch connector for power supply and FG.
4 - 33 4 - 33
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
F
7
device
Number of occupied stations 32-point assignment/station (16 points used)
AJ65VBTCE3-16D
E
6
Module Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
D
5
power supply Current 35mA or lower (at 24VDC and all points ON)
C
4
Noise immunity Noise voltage 500Vp-p, noise width 1µs,
B
noise frequency 25 to 60Hz (DC type noise simulator condition)
3
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
A
2
Insulation resistance 10MΩ or higher between all DC external terminals and ground (500VDC
9
insulation resistance tester)
8
Protection degree IP1XB
X
Weight 0.10kg
External Communication One-touch connector for communication [Transmission circuit]
D
8 9 A B C D E F
0 1 2 3 4 5 6 7
system <Optional>
C
Online connector for communication: A6CON-LJ5P
Power supply One-touch connector for power supply and FG
B
ON
CON A
5-pin IDC plug is sold separately: A6CON-PW5P, A6CON-PW5P-SOD
<Optional>
Online connector for power supply: A6CON-PWJ5P
I/O part Sensor connector (e-CON) [I/O signals]
1
4-pin IDC plug is sold separately.
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
Applicable Connector for Applicable cable:
wire size communication FANC-110SBH, FA-CBL200PSBH, CS-110
Connector for 0.66 to 0.98mm2 (AWG18)
power supply [φ2.2 to 3.0mm (A6CON-PW5P), φ2.0 to 2.3mm (A6CON-PW5P-SOD)]
and FG Wire diameter: 0.16mm or more
Insulating coating material: PVC (heat-resistant)
Connector for Sensor connector (e-CON).
1
I/O Applicable connector plugs are sold separately.
(applicable wire size: 0.08 to 0.5mm2, depending on the connector plug)
Accessory User’s manual, Holding fixtures for screw installation
4 - 34 4 - 34
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
CON16
1
2
3
4
1: Attach an unwired connector plug to an unused one-touch connector for power supply and FG.
2: Wiring the sensor connector (e-CON) incorrectly may cause malfunction or failure due to short circuit of the power supply.
Pin layout
4 - 35 4 - 35
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
1: Attach an unwired connector plug to an unused one-touch connector for power supply and FG.
4 - 36 4 - 36
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
1F
Wiring method for common 32 points/common (3-wire, sensor connector (e-CON) type)
1E
Input type Positive common (sink type)
1D
Supply current for connected 2.0A or lower/common
D
device
1C
C
Number of occupied stations 32-point assignment/station (32 points used)
1B
B
Module power Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
1A
A
supply Current 40mA or lower (at 24VDC and all points ON)
19
9
Noise immunity Noise voltage 500Vp-p, noise width 1µs,
18
AJ65VBTCE3-32D
8
noise frequency 25 to 60Hz (DC type noise simulator condition)
17
7
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
16
6
Insulation resistance 10MΩ or higher between all DC external terminals and ground (500VDC insulation
15
5
resistance tester)
14
4
Protection degree IP1XB
13
3
Weight 0.16kg
12
2
External Communication One-touch connector for communication [Transmission circuit]
11
1
connection part 5-pin IDC plug is sold separately: A6CON-L5P
10
0
system <Optional>
X
Online connector for communication: A6CON-LJ5P
D
8 9 A B C D E F
0 1 2 3 4 5 6 7
C
5-pin IDC plug is sold separately: A6CON-PW5P, A6CON-PW5P-SOD
B
<Optional>
ON
4 - 37 4 - 37
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
1: Attach an unwired connector plug to an unused one-touch connector for power supply and FG.
2: Wiring the sensor connector (e-CON) incorrectly may cause malfunction or failure due to short circuit of the power supply.
4 - 38 4 - 38
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
1: Attach an unwired connector plug to an unused one-touch connector for power supply and FG.
Pin layout
4 - 39 4 - 39
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
4 - 40 4 - 40
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
1: Attach an unwired connector plug to an unused one-touch connector for power supply and FG.
2: Wiring the sensor connector (e-CON) incorrectly may cause malfunction or failure due to short circuit of the power supply.
Pin layout
4 - 41 4 - 41
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
1: Attach an unwired connector plug to an unused one-touch connector for power supply and FG.
4 - 42 4 - 42
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
4 - 43 4 - 43
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
1: Attach an unwired connector plug to an unused one-touch connector for power supply and FG.
2: Wiring the sensor connector (e-CON) incorrectly may cause malfunction or failure due to short circuit of the power supply.
4 - 44 4 - 44
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
1: Attach an unwired connector plug to an unused one-touch connector for power supply and FG.
Pin layout
4 - 45 4 - 45
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
supply Current 35mA or lower (at 24VDC and all points ON) L RUN
X1
Noise immunity Noise voltage 500Vp-p, noise width 1µs, L ERR
system <Optional>
X7
Online connector for communication: A6CON-LJ5P
Power supply part One-touch connector for power supply and FG
[Module power supply, I/O power supply, FG] CON
5-pin IDC plug is sold separately: A6CON-PW5P, A6CON-PW5P-SOD C
<Optional>
Online connector for power supply: A6CON-PWJ5P CON
D
I/O part One-touch connector for I/O
4-pin IDC plug is sold separately.
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
Applicable Connector for Applicable cable:
wire size communication FANC-110SBH, FA-CBL200PSBH, CS-110
Connector for power 0.66 to 0.98mm2 (AWG18)
supply and FG [φ2.2 to 3.0mm (A6CON-PW5P), φ2.0 to 2.3mm (A6CON-PW5P-SOD)]
Wire diameter: 0.16mm or more
Insulating coating material: PVC (heat-resistant)
Connector for φ1.0 to 1.4 (A6CON-P214), φ1.4 to 2.0 (A6CON-P220)
I/O [Applicable wire size: 0.14 to 0.2mm2]
φ1.0 to 1.4 (A6CON-P514), φ1.4 to 2.0 (A6CON-P520)
[Applicable wire size: 0.3 to 0.5mm2]
Accessory User’s manual
4 - 46 4 - 46
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
Pin Signal
Pin layout
number name
1 DA
2 DB
CON
3 DG
CONA A, B
1
1 DA
4 Empty
LINK CABLE 2
(IN) 3
2 DB 5 SLD
3 DG
4
4 Empty 1 X0
5
5 SLD 2 +V
CONB CON1
1
1 DA 3 +24V
LINK CABLE 2
(OUT) 3
2 DB 4 24G
3 DG
4 1 X1
4 Empty
5
5 SLD
2 +V
One-touch connector for communication 5 4 3 2 1
CON2
3 +24V
CONC Insulation 4 24G
1 CONA
UNIT POWER CABLE(IN) 1 FG
2 1 X2
2 +24V(UNIT)
3 CONB
3 24G(UNIT)
4 2 +V
5
4 +24V(I/O) CON3
5 24G(I/O) 43 2 1 3 +24V
I/O POWER CABLE(IN) COND
1 CON1 4 24G
UNIT POWER CABLE(OUT) 1 FG
2
2 +24V(UNIT) 1 X3
3
3 24G(UNIT) CON2
4
4 +24V(I/O)
2 +V
5 CON4
5 24G(I/O) CON3 3 +24V
I/O POWER CABLE(OUT)
1 CON4 4 24G
One-touch connector for power supply and FG
1 X4
CON1 CON5
Black
2 +V
3-wire sensor 1 CON5
(sink output)
Brown 2 CON6 3 +24V
3
Detection Blue 4 4 24G
circuit CON7
1 X5
CON2 CON8 2 +V
Brown 1
CON6
2-wire sensor 3 +24V
(sink output) 2 5 4 3 2 1
Detection 3 4 24G
circuit Blue 4
CONC 1 X6
COND 2 +V
CON7
3 +24V
Viewed from the 4 24G
CON8
front of the module
1 1 X7
2
3 2 +V
CON8
4 3 +24V
4 24G
1 (FG)
2 +24V
(UNIT)
CON 3 24G
C, D (UNIT)
4 +24V
(I/O)
1: Attach an unwired connector plug to an unused one-touch connector for power supply and FG. 5 24G (I/O)
4 - 47 4 - 47
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
Online connector
for communication
CONA
1
1 DA
LINK CABLE 2
(IN) 2 DB
3
3 DG
4
4
5
5 SLD
CONB
1
1 DA
LINK CABLE 2
(OUT) 2 DB
3
3 DG
4
4
5
5 SLD
One-touch connector
for communication
CONC
1
UNIT POWER CABLE(IN) 1 FG
2
2 +24V(UNIT)
3
3 24G(UNIT)
4
4 +24V(I/O)
5
5 24G(I/O)
I/O POWER CABLE(IN) COND
1
1 FG
2
UNIT POWER 2 +24V(UNIT)
CABLE(OUT) 3
3 24G(UNIT)
4
I/O POWER 4 +24V(I/O)
CABLE(OUT) 5
5 24G(I/O)
1: Attach an unwired connector plug to an unused one-touch connector for power supply and FG.
4 - 48 4 - 48
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
4.4.2 AJ65SBTC4-16D 24VDC input module (positive common (sink), negative common
(source) loading)
COM-
CTL+
Module power supply Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
40 20 10 8 4 2 1 4 2 1
B RATE
Current 35mA or lower (at 24VDC and all points ON)
+24V
24G
XF
X7
STATION NO.
Noise immunity Noise voltage 500Vp-p, noise width 1µs,
+24V
24G
XE
X6
noise frequency 25 to 60Hz (DC type noise simulator condition)
+24V
24G
XD
X5
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
ON
Insulation resistance 10MΩ or higher between all DC external terminals and ground (500VDC
+24V
24G
XC
X4
insulation resistance tester)
+24V
24G
X8 9 A B C D E F
XB
X3
Protection degree IP2X
+24V
24G
XA
X2
Weight 0.15kg
AJ65SBTC4-16D
+24V
24G
X1
X9
External Communication part, 7-point two-piece terminal block
connection module power supply part [Transmission circuit, module power supply, FG]
+24V
24G
X0
X8
system M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m) X0 1 2 3 4 5 6 7
(FG)
24G
Applicable solderless terminal: 2 or less
I/O power supply part 2-point direct-mount terminal block
+24V
SLD
[I/O power supply]
DG
4 - 49 4 - 49
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
1 DA
2 DB
3 DG Insulation
4 SLD
5 +24V
6 FG
7 24G
Module power supply
4-wire sensor
CON1
(sink output) Black 1
Detection
circuit White 2
Brown 3
Blue 4
3-wire sensor
CON2
(sink output)
Black 1
Detection
circuit 2
Brown 3
Blue 4
Sink/source switch
Source type Sink type
8 CTL+
9 COM-
Terminal
Pin layout Signal name Pin number Signal name
number
TB1 DA 1 X4
TB2 DB 2 XC
CON5
TB3 DG 3 +24V
TB4 SLD 4 24G
TB5 +24V 1 X5
TB6 (FG) 2 XD
CON6
TB7 24G 3 +24V
4 24G
Pin number Signal name
1 X6
1 X0 2 XE
CON7
2 X8 3 +24V
CON1
3 +24V 4 24G
4 24G 1 X7
1 X1 2 XF
CON8
Viewed from the front of the module 2 X9 3 +24V
CON2
3 +24V 4 24G
4 24G Terminal
Signal name
1 X2 number
2 XA TB8 CTL+
CON3
3 +24V TB9 COM-
4 24G
1 X3
2 XB
CON4
3 +24
4 24G
4 - 50 4 - 50
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
1 DA
2 DB
3 DG Insulation
4 SLD
5 +24V
6 FG
7 24G
Module power supply
Terminal
Pin layout Signal name Pin number Signal name
number
TB1 DA 1 X4
TB2 DB 2 XC
CON5
TB3 DG 3 +24V
TB4 SLD 4 24G
TB5 +24V 1 X5
TB6 (FG) 2 XD
CON6
TB7 24G 3 +24V
4 24G
Pin number Signal name
1 X6
1 X0 2 XE
CON7
2 X8 3 +24V
CON1
3 +24V 4 24G
4 24G 1 X7
1 X1 2 XF
CON8
Viewed from the front of the module 2 X9 3 +24V
CON2
3 +24V 4 24G
4 24G Terminal
Signal name
1 X2 number
2 XA TB8 CTL+
CON3
3 +24V TB9 COM-
4 24G
1 X3
2 XB
CON4
3 +24
4 24G
4 - 51 4 - 51
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
ON
Number of occupied stations 32-point assignment/station (16 points used)
COM-
COM+
40 20 10 8 4 2 1 4 2 1
Module power supply Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
B RATE
Current 35mA or lower (at 24VDC and all points ON)
+24V
24G
XF
X7
STATION NO.
Noise immunity Noise voltage 500Vp-p, noise width 1µs,
+24V
24G
XE
X6
noise frequency 25 to 60Hz (DC type noise simulator condition)
+24V
24G
XD
X5
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
+24V
24G
Insulation resistance 10MΩ or higher between all DC external terminals and ground (500VDC
XC
X4
insulation resistance tester)
+24V
24G
XB
X3
X8 9 A B C D E F
Protection degree IP2X
+24V
24G
XA
X2
Weight 0.15kg
AJ65SBTC4-16DN
+24V
24G
X1
X9
External Communication part, 7-point two-piece terminal block
+24V
24G
connection module power supply part [Transmission circuit, module power supply, FG]
X0
X8
PW L RUN L ERR. X0 1 2 3 4 5 6 7
system M3×5.2 screw (tightening torque range:0.59 to 0.88N•m)
(FG)
24G
Applicable solderless terminal: 2 or less
I/O power supply part 2-point direct-mount terminal block
+24V
SLD
[I/O power supply]
M3×5.2 screw (tightening torque range:0.59 to 0.88N•m) DG
DB
DA
4 - 52 4 - 52
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
Terminal Signal
number name
TB1 DA
TB2 DB
TB3 DG
TB4 SLD
TB5 +24V
TB6 (FG)
1 DA TB7 24G
2 DB
3 DG
Pin Signal
Insulation
4 SLD number name
5 +24V 1 X0
6 FG
7 24G
2 X8
Module power supply CON1
3 +24V
4 24G
4-wire sensor
CON1 1 X1
(sink output)
Black 1
Detection 2 X9
circuit White 2 CON2
Brown 3 3 +24V
Blue 4 4 24G
1 X2
3-wire sensor
CON2 2 XA
(sink output) CON3
Black 1 3 +24V
Detection
circuit 2
Brown 3 4 24G
Blue 4 1 X3
2 XB
CON4
3 +24
4 24G
1 X4
2-wire sensor CON8 2 XC
(sink output) Brown 1
CON5
3 +24V
Detection 2
circuit
3 4 24G
Blue 4 1 X5
2 XD
The cable colors are selected according to CON6
3 +24V
IEC 60947-5-2 (JIS C 8201-5-2).
4 24G
1 X6
2 XE
CON7
3 +24V
8 COM+
9 COM- 4 24G
1 X7
2 XF
CON8
3 +24V
4 24G
Terminal Signal
number name
TB8 COM+
TB9 COM-
Pin layout
4 - 53 4 - 53
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
ON
Number of occupied stations 32-point assignment/station (16 points used)
COM-
COM+
40 20 10 8 4 2 1 4 2 1
Module power supply Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
B RATE
Current 35mA or lower (at 24VDC and all points ON)
+24V
24G
XF
X7
STATION NO.
Noise immunity Noise voltage 500Vp-p, noise width 1µs,
+24V
24G
XE
X6
noise frequency 25 to 60Hz (DC type noise simulator condition)
+24V
24G
XD
X5
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
+24V
24G
Insulation resistance 10MΩ or higher between all DC external terminals and ground (500VDC
XC
X4
insulation resistance tester)
+24V
24G
XB
X3
X8 9 A B C D E F
Protection degree IP2X
+24V
24G
XA
X2
Weight 0.15kg
AJ65SBTC4-16DE
+24V
24G
X1
X9
External Communication part, 7-point two-piece terminal block
+24V
24G
connection module power supply part [Transmission circuit, module power supply, FG]
X0
X8
PW L RUN L ERR. X0 1 2 3 4 5 6 7
system M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
(FG)
24G
Applicable solderless terminal: 2 or less
I/O power supply part 2-point direct-mount terminal block
+24V
SLD
[I/O power supply]
M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m) DG
DB
DA
4 - 54 4 - 54
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
Terminal Signal
number name
TB1 DA
TB2 DB
TB3 DG
TB4 SLD
TB5 +24V
TB6 (FG)
TB7 24G
1 DA
2 DB Signal
Pin number
3 DG Insulation name
4 SLD
5 +24V
1 X0
6 FG 2 X8
7 24G
CON1
Module power supply 3 +24V
4 24G
4-wire sensor 1 X1
CON1
(source output)
Black 1 2 X9
Detection
White 2
CON2
circuit 3 +24V
Brown 3
Blue 4 4 24G
1 X2
3-wire sensor CON2 2 XA
(source output) CON3
Black 1 3 +24V
Detection 2
circuit
Brown
4 24G
3
Blue 4 1 X3
2 XB
CON4
3 +24
4 24G
1 X4
2-wire sensor CON8 2 XC
(source output) Brown 1 CON5
Detection 3 +24V
2
circuit Blue 4 24G
3
4 1 X5
2 XD
CON6
The cable colors are selected according to 3 +24V
IEC 60947-5-2 (JIS C 8201-5-2). 4 24G
1 X6
2 XE
CON7
8 COM+ 3 +24V
9 COM-
4 24G
1 X7
2 XF
CON8
3 +24V
4 24G
Terminal Signal
number name
TB8 COM+
TB9 COM-
Pin layout
4 - 55 4 - 55
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
device
CON
Number of occupied stations 32-point assignment/station (16 points used) B
4 - 56 4 - 56
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
Pin
Pin layout Signal name
number
1 DA
2 DB
CON
3 DG
A, B
4 Empty
5 SLD
1 X0
CON 2 +V
1 3 +24V
4 24G
1 X1
CON 2 +V
CONA 2
1 3 +24V
1 DA
LINK CABLE 2
2 DB 4 24G
(IN) 3
4
3 DG 1 X2
4 Empty
5
5
CON 2 +V
SLD
3 3 +24V
CONB
1
1 DA 4 24G
LINK CABLE 2
(OUT) 3
2 DB 1 X3
3 DG
4
4 Empty
CON 2 +V
5
5 SLD 4 3 +24V
One-touch connector for communication 4 24G
1 X4
CONC Insulation
UNIT POWER CABLE(IN) 1
1 FG CON 2 +V
2 5
3
2 +24V(UNIT) 3 +24V
24G(UNIT)
4
3 4 24G
4 +24V(I/O)
5
5 24G(I/O) 5 4 3 2 1 1 X5
I/O POWER CABLE(IN) COND CON 2 +V
1 CONA
UNIT POWER CABLE(OUT)
2
1 FG 6 3 +24V
3
2 +24V(UNIT) CONB 4 24G
3 24G(UNIT)
4
4 +24V(I/O) 4321 4321 1 X6
5
5 24G(I/O) CON 2 +V
I/O POWER CABLE(OUT) CON1 CON9
7 3 +24V
1
One-touch connector for power supply and FG CON2 CON10 4 24G
CON1 1 X7
CON3 CON11
3-wire sensor
Black 1 CON 2 +V
Brown 2 8
(sink output) 3
CON4 CON12 3 +24V
Detection Blue 4 4 24G
circuit CON5 CON13
1 X8
CON2
CON6 CON14 CON 2 +V
2-wire sensor Brown 1 9 3 +24V
CON7 CON15
(sink output) 2 4 24G
Detection 3
circuit Blue 4
CON8 CON16 1 X9
CON 2 +V
5 4 3 2 1 10 3 +24V
CONC 4 24G
COND 1 XA
CON16
CON 2 +V
1
2 11 3 +24V
Viewed from the front of the module
3 4 24G
4
1 XB
CON 2 +V
12 3 +24V
4 24G
1 XC
CON 2 +V
13 3 +24V
4 24G
1 XD
CON 2 +V
14 3 +24V
4 24G
1 XE
CON 2 +V
15 3 +24V
4 24G
1 XF
CON 2 +V
16 3 +24V
4 24G
1 (FG)
2 +24V (UNIT)
CON
1: Attach an unwired connector plug to an unused one-touch connector for power supply 3 24G (UNIT)
C, D
and FG. 4 +24V (I/O)
5 24G (I/O)
4 - 57 4 - 57
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
1: Attach an unwired connector plug to an unused one-touch connector for power supply and FG.
4 - 58 4 - 58
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
4.4.6 AJ65SBTC1-32D 24VDC input module (positive common (sink), negative common
(source) loading)
ON
Input type Positive/negative common shared type (sink/source shared type)
COM
COM
Number of occupied stations 32-point assignment/station (32 points used)
B RATE
40 20 10 8 4 2 1 4 2 1
Module power supply Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
X1C
X1D
X1E
X1F
STATION NO.
Current 45mA or lower (at 24VDC and all points ON)
X1A
X1B
X18
X19
Noise immunity Noise voltage 500Vp-p, noise width 1µs,
noise frequency 25 to 60Hz (DC type noise simulator condition)
X14
X15
X16
X17
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
X10-X1F
X0-XF
X10
X11
X12
X13
Insulation resistance 10MΩ or higher between all DC external terminals and ground (500VDC
insulation resistance tester)
XC
XD
XE
XF
X1011121314 151617 X1819 1A1B1C1D1E1F
X8 9 A B C D E F
Weight 0.16kg
XA
XB
X8
X9
A J65SBTC1-32D
External Communication part, 7-point two-piece terminal block
connection module power supply part [Transmission circuit, module power supply, FG]
X4
X5
X6
X7
system M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
X0
X1
X2
X3
X0 1 2 3 4 5 6 7
Applicable solderless terminal: 2 or less
I/O power supply part 2-point direct-mount terminal block
(FG)
24G
[I/O power supply]
DA DG +24V
M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
Applicable solderless terminal: 2 or less DB SLD
4 - 59 4 - 59
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
Terminal
Signal name
number
TB1 DA
TB2 DB
TB3 DG
TB4 SLD
TB5 +24V
TB6 (FG)
1 DA
2 DB TB7 24G
3 DG Insulation Pin number Signal name
4 SLD 1 X0
5 +24V
2 X1
6 FG CON1
7 24G 3 X2
Module power supply 4 X3
CON1
1 1 X4
2 2 X5
CON2
3 3 X6
4
4 X7
1 X8
2 X9
CON3
3 XA
4 XB
1 XC
2 XD
CON4
3 XE
4 XF
1 X10
2 X11
CON5
3 X12
4 X13
CON8
1 1 X14
2 2 X15
CON6
3 3 X16
4
4 X17
1 X18
2 X19
CON7
8 COM 3 X1A
9 COM 4 X1B
1 X1C
2 X1D
CON8
3 X1E
4 X1F
Terminal
Signal name
number
TB8 COM
TB9 COM
Pin layout
4 - 60 4 - 60
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
4.4.7 AJ65SBTC1-32D1 24VDC input module (positive common (sink), negative common
(source) loading)
ON
COM
Number of occupied stations 32-point assignment/station (32 points used)
COM
B RATE
40 20 10 8 4 2 1 4 2 1
Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
Modulepower supply
X1C
X1D
X1E
X1F
Current 45mA or lower (at 24VDC and all points ON)
STATION NO.
Noise voltage 500Vp-p, noise width 1µs,
X1A
X1B
X18
X19
Noise immunity
noise frequency 25 to 60Hz (DC type noise simulator condition)
X14
X15
X16
X17
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
X10-X1F
10MΩ or higher between all DC external terminals and ground (500VDC
X0-XF
X10
X11
X12
X13
Insulation resistance
insulation resistance tester)
XC
XD
XE
XF
X1011121314 1516 17 X1819 1A1B1C1D1E1F
X8 9 A B C D E F
Protection degree IP2X
Weight 0.16kg
XA
XB
X8
X9
A J65SBTC1-32D1
External Communication part, 7-point two-piece terminal block
X4
X5
X6
X7
connection module power supply part [Transmission circuit, module power supply, FG]
X0
X1
X2
X3
system M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m) X0 1 2 3 4 5 6 7
Applicable solderless terminal: 2 or less
(FG)
24G
I/O power supply part 2-point direct-mount terminal block
[I/O power supply] DA DG +24V
M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m) SLD
4 - 61 4 - 61
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
Terminal
Signal name
number
TB1 DA
TB2 DB
TB3 DG
TB4 SLD
TB5 +24V
1 DA TB6 (FG)
2 DB TB7 24G
3 DG Insulation
Pin number Signal name
4 SLD
5 +24V 1 X0
6 FG 2 X1
7 24G
CON1
3 X2
Module power supply
CON1 4 X3
1 1 X4
2 2 X5
3 CON2
3 X6
4
4 X7
1 X8
2 X9
CON3
3 XA
4 XB
1 XC
2 XD
CON4
3 XE
4 XF
1 X10
2 X11
CON5
3 X12
4 X13
CON8
1 X14
1
2 2 X15
CON6
3 3 X16
4 4 X17
1 X18
2 X19
CON7
3 X1A
8 COM
4 X1B
9 COM
1 X1C
2 X1D
CON8
3 X1E
4 X1F
Terminal
Signal name
number
TB8 COM
TB9 COM
Pin layout
4 - 62 4 - 62
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
4.5.1 AJ65SBTCF1-32D 24VDC input module (positive common (sink), negative common
(source) loading)
Type DC input module
Item AJ65SBTCF1-32D Appearance
Number of input points 32 points
Isolation method Photocoupler
Rated input voltage 24VDC
Rated input current Approx. 5mA
Operating voltage range 19.2 to 26.4VDC (ripple ratio: within 5%)
Max. number of simultaneous input points 100%
ON voltage/ON current 14VDC or higher/3.5mA or higher
OFF voltage/OFF current 6VDC or lower/1.7mA or lower
Input resistance Approx. 4.7kΩ
Response time OFF→ON 1.5ms or less (at 24VDC)
ON→OFF 1.5ms or less (at 24VDC)
Wiring method for common 32 points/common (1-wire, FCN connector type)
ON
Input type Positive/negative common shared type (sink/source shared type)
X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF NC NC COM COM
B RATE
X10 X11 X12 X13 X14 X15 X16 X17 X18 X19 X1A X1B X1C X1D X1E X1F NC NC NC NC
40 20 10 8 4 2 1 4 2 1
Number of occupied stations 32-point assignment/station (32 points used)
Module power supply Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
STATION NO.
Current 45mA or lower (at 24VDC and all points ON)
Noise immunity Noise voltage 500Vp-p, noise width 1µs,
noise frequency 25 to 60Hz (DC type noise simulator condition)
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
X10-X1F
X0-XF
Insulation resistance 10MΩ or higher between all DC external terminals and ground (500VDC
A J65SBTCF1-32D
Weight 0.15kg
External Communication part, 7-point two-piece terminal block
connection module power supply part [Transmission circuit, module power supply, FG]
X0 1 2 3 4 5 6 7
(FG)
Applicable solderless terminal: 2 or less 24G
I/O power supply part, 40-pin connector [I/O power supply, I/O signal]
+24V
4 - 63 4 - 63
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
Pin layout Terminal number Signal name
TB1 DA
1 DA TB2 DB
2 DB TB3 DG
3 DG Insulation TB4 SLD
4 SLD
5 +24V TB5 +24V
6 FG TB6 (FG)
7 24G
Module power supply TB7 24G
Pin Signal Pin Signal
B20 X0 number name number name
B19 X1
B18 X2
B20 X0 A20 X10
B17 X3 B19 X1 A19 X11
B16 X4 B18 X2 A18 X12
B15 X5
B14
B17 X3 A17 X13
X6
B13 X7 B16 X4 A16 X14
B12 X8 B15 X5 A15 X15
B11 X9
B14 X6 A14 X16
B10 XA
B9 XB B13 X7 A13 X17
B8 XC B12 X8 A12 X18
B7 XD
B11 X9 A11 X19
B6 XE
B5 XF B10 XA A10 X1A
A20 X10 Viewed from the B9 XB A9 X1B
A19 X11 front of the B8 XC A8 X1C
A18 X12 module
A17 X13 B7 XD A7 X1D
A16 X14 B6 XE A6 X1E
A15 X15 B5 XF A5 X1F
A14 X16
A13 X17
B4 Empty A4 Empty
A12 X18 B3 Empty A3 Empty
A11 X19 B2 COM A2 Empty
A10 X1A
B1 COM A1 Empty
A9 X1B
A8 X1C
A7 X1D
A6 X1E
A5 X1F
B2 COM
B1 COM
4 - 64 4 - 64
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
4 - 65 4 - 65
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
Pin layout Connector for communication
Pin
LINK IN LINK OUT
number
LINK IN
4 1 SLD SLD
2
3 2 DB DB
1 Communication
circuit 3 DG DG
110
4 DA DA
LINK OUT 130
4 5 No pins Empty
2
3 Terminating resistor Connector for power supply
1 setting switch
5
Pin
UNIT POWER AUX.
LINK IN number
Male 1 +24V(UNIT) +24V(I/O)
Insulation
UNIT POWER 2 1 2 Empty Empty
1 3 4
3 3 24G(UNIT) 24G(I/O)
5
2 4 Empty Empty
4 LINK OUT
Module mounting screw (FG) 5 FG FG
Female
Connector for I/O
1 2
5
AUX.
1
4 3 Pin Signal Pin Signal
3 number name number name
5
Connector for I/O 1 +24V 1 +24V
2 UNIT POWER/AUX.
4
Male 2 X1 2 X9
X0 X8
2 5
1 X1 3 24G X9 3 24G
4-wire sensor 3 4
(sink output) Black 4
4 X0 4 X8
Detection
circuit White 2 5 Empty 5 Empty
Brown 1
Blue 3
I/O connector 1 +24V 1 +24V
5 Female 2 X3 2 XB
3-wire sensor 1
5
2 X2 XA
(sink output)
4 3 X3 3 24G XB 3 24G
Black 4
Detection 2 4 X2 4 XA
circuit
Brown 1
Blue 3
5 Empty 5 Empty
5 Front view 1 +24V 1 +24V
2 X5 2 XD
X4 XC
2-wire sensor X5 3 24G XD 3 24G
(sink output) Brown 4 4 X4 4 XC
Detection 2
circuit 1 5 Empty 5 Empty
Blue 3
5 1 +24V 1 +24V
2 X7 2 XF
X6 XE
X7 3 24G XF 3 24G
4 X6 4 XE
5 Empty 5 Empty
4 - 66 4 - 66
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
4 - 67 4 - 67
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
External connection
Pin layout Connector for communication
Pin
LINK IN LINK OUT
number
1 SLD SLD
LINK IN 4 2 DB DB
2
3 3 DG DG
1 Communication
circuit
4 DA DA
110
5 No pins Empty
LINK OUT 130
4 Connector for power supply
2
3 Terminating resistor Pin UNIT
1 setting switch AUX.
5 number POWER
+24V
LINK IN 1 +24V(I/O)
(UNIT)
Insulation Male
UNIT POWER
1
2 Empty Empty
2 1
3 3 4 24G
5 3 24G(I/O)
2 (UNIT)
4
Module mounting screw (FG) LINK OUT 4 Empty Empty
Female 5 FG FG
AUX. 1 2
1 4 5
3 Connector for I/O
3
5 Pin Signal Pin Signal
Connector for I/O 2
4 UNIT POWER/AUX. number name number name
Male
1 +24V 1 +24V
4-wire sensor 2 5
1 2 X1 2 X9
(source output) Black 4
3 4 X0 X8
Detection
White 2 X1 3 24G X9 3 24G
circuit
Brown 1 4 X0 4 X8
Blue 3 I/O connector
5 5 Empty 5 Empty
Female
3-wire sensor 1
5
2 1 +24V 1 +24V
4 3
(source output) Black 4
Detection 2 X3 2 XB
circuit
2 X2 XA
Brown 1
X3 3 24G XB 3 24G
Blue 3
5 Front view 4 X2 4 XA
5 Empty 5 Empty
1 +24V 1 +24V
2-wire sensor 2 X5 2 XD
(source output) X4 XC
Detection
Brown 4
X5 3 24G XD 3 24G
circuit 2
1 4 X4 4 XC
Blue 3
5 5 Empty 5 Empty
1 +24V 1 +24V
2 X7 2 XF
X6 XE
X7 3 24G XF 3 24G
4 X6 4 XE
5 Empty 5 Empty
4 - 68 4 - 68
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
4.6.3 AJ65SBTW4-16D 24VDC input module (positive common (sink), negative common
(source) loading)
Type DC input module
Item AJ65SBTW4-16D Appearance
Operating ambient temperature 0 to 45°C
*1 *3
Storage ambient temperature -20 to 65°C
Number of input points 16 points
Isolation method Photocoupler
Rated input voltage 24VDC
Rated input current Approx. 5mA
Operating voltage range 20.4 to 26.4VDC (ripple ratio: within 5%)
Max. number of simultaneous input
100%
points
ON voltage/ON current 14VDC or higher/3.5mA or higher
OFF voltage/OFF current 6VDC or lower/1.7mA or lower
Input resistance Approx. 4.7kΩ
AJ65SBTW4-16D
OFF→ON 1.5ms or less (at 24VDC)
Response time
L ERR.
L RUN
ON→OFF 1.5ms or less (at 24VDC)
YC
YD
YA
YB
YE
YF
Y8
Y9
STATION NO.
16 points/common (4-wire, waterproof connector type)
Wiring method for common
Same as that for the module power supply
PW
X0
X1
X2
X3
X4
X5
X6
X7
MITSUBISHI
Positive/negative common shared type (sink/source shared type)
Input type
(Selected using the switch.)
Number of occupied stations 32-point assignment/station (16 points used)
CON7
CON8
Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
Module power supply 35mA or lower (at 24VDC and all points ON),
Current
excluding input current for I/O part
Noise voltage 500Vp-p, noise width 1µs,
CON5
CON6
Noise immunity
noise frequency 25 to 60Hz (DC type noise simulator condition)
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
10MΩ or higher between all DC external terminals and ground (500VDC
Insulation resistance
insulation resistance tester)
CON3
CON4
Protection degree IP67
Weight 0.70kg
7-point two-piece terminal block
[Transmission circuit, module power supply, FG]
CON1
CON2
POWER CABL
External connection system [compliant with IEC 60947-5-2, M12, male, 4 pins, IP67]
(connector for I/O)
<Optional>
OUT
IN
LINK CABL
4 - 69 4 - 69
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
4 - 70 4 - 70
4 SPECIFICATIONS FOR INPUT MODULES
MELSEC-A
4 - 71 4 - 71
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
COM-
CTL+
B RATE
40 20 10 8 4 2 1 4 2 1
Wiring method for common 8 points/common (1-wire, terminal block type)
Y7
Number of occupied stations 32-point assignment/station (8 points used)
Y6
Y5
STATION NO.
Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
Module power supply
Y4
Current 35mA or lower (at 24VDC and all points ON)
Y3
Y2
Noise voltage 500Vp-p, noise width 1µs,
Noise immunity
Y1
noise frequency 25 to 60Hz (DC type noise simulator condition)
ON
Y0
Y0 1 2 3 4 5 6 7
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
10MΩ or higher between all DC external terminals and ground (500VDC
A J65SBTB1-8T
24G
(FG)
Insulation resistance
insulation resistance tester)
DA DG +24V
Weight 0.14kg
DB
5-1 5-1
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
1 DA TB2 DB
2 DB
TB3 DG
3 DG Insulation
4 SLD TB4 SLD
5 +24V TB5 +24V
6 FG
7 24G TB6 (FG)
Module power supply TB7 24G
Load
8 Y0 TB8 Y0
9 Y1 TB9 Y1
10 Y2
11 Y3 TB10 Y2
12 Y4 TB11 Y3
13 Y5
14 Y6 TB12 Y4
Load
15 Y7 TB13 Y5
External power supply for output part 16 CTL
17 COM-
TB14 Y6
TB15 Y7
Load power supply TB16 CTL+
Constant-voltage circuit TB17 COM-
Load
External power supply for output
part and load power supply
16 CTL (common)
17 COM-
5-2 5-2
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
COM-
CTL+
B RATE
40 20 10 8 4 2 1 4 2 1
Wiring method for common 8 points/common (1-wire, terminal block type)
Y7
Number of occupied stations 32-point assignment/station (8 points used)
Y6
Y5
STATION NO.
Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
Module power supply
Y4
Current 35mA or lower (at 24VDC and all points ON)
Y3
Y2
Noise voltage 500Vp-p, noise width 1µs,
Noise immunity
Y1
noise frequency 25 to 60Hz (DC type noise simulator condition)
ON
Y0
Y0 1 2 3 4 5 6 7
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
10MΩ or higher between all DC external terminals and ground (500VDC
A J65SBTB1-8T1
24G
(FG)
Insulation resistance
insulation resistance tester)
+24V
Protection degree IP2X
SLD
Weight 0.14kg
DG
DB
7-point two-piece terminal block
DA
Communication part, [Transmission circuit, module power supply, FG]
module power supply part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
External
Applicable solderless terminal: 2 or less
connection
10-point direct-mount terminal block
system
I/O power supply part, [I/O power supply, I/O signal]
I/O part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
Applicable solderless terminal: 2 or less
M4 screw with plain washer finished round
Module mounting screw (tightening torque range: 0.78 to 1.08N•m)
Mountable with a DIN rail in 6 orientations
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
y RAV1.25-3 (compliant with JIS C 2805)
[Applicable wire size: 0.3 to 1.25mm2]
Applicable solderless terminal
y V2-MS3, RAP2-3SL, TGV2-3N
[Applicable wire size: 1.25 to 2.0mm2]
Accessory User’s manual
5-3 5-3
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
1 DA TB2 DB
2 DB
TB3 DG
3 DG Insulation
4 SLD TB4 SLD
5 +24V TB5 +24V
6 FG
7 24G TB6 (FG)
Module power supply
TB7 24G
Load TB8 Y0
8 Y0
9 Y1 TB9 Y1
10 Y2
TB10 Y2
11 Y3
12 Y4 TB11 Y3
13 Y5
TB12 Y4
Load 14 Y6
15 Y7 TB13 Y5
External power supply for output part 16 CTL+ TB14 Y6
17 COM-
TB15 Y7
TB16 CTL+
Load power supply
TB17 COM-
Constant-voltage circuit
Load
External power supply for output
part and load power supply
16 CTL+ (common)
17 COM-
5-4 5-4
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
DC24G
External power supply for Voltage 10.2 to 26.4VDC (ripple ratio: within 5%)
DC24V
B RATE
40 20 10 8 4 2 1 4 2 1
COM
output part Current 17.8mA or lower (TYP. 24VDC/common), excluding external load current
Y7
COM
Surge suppressor Zener diode
STATION NO.
Y6
Wiring method for common 8 points/common (2-wire, terminal block type)
COM
Number of occupied stations 32-point assignment/station (8 points used)
Y5
COM
Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
ON
Module power supply
Y4
COM
Current 45mA or lower (at 24VDC and all points ON)
Y3
Noise voltage 500Vp-p, noise width 1µs,
COM
Noise immunity
noise frequency 25 to 60Hz (DC type noise simulator condition)
Y2
COM
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
AJ65SBTB2-8T
Y1
10MΩ or higher between all DC external terminals and ground (500VDC
COM
Insulation resistance
insulation resistance tester)
Y0
Y0 1 2 3 4 5 6 7
Protection degree IP2X
Weight 0.18kg
(FG)
24G
7-point two-piece terminal block
DA DG +24V
Communication part, [Transmission circuit, module power supply, FG]
SLD
module power supply part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
External
DB
Applicable solderless terminal: 2 or less
connection
18-point direct-mount terminal block
system
I/O power supply part, [I/O power supply, I/O signal]
I/O part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
Applicable solderless terminal: 2 or less
M4 screw with plain washer finished round
Module mounting screw (tightening torque range: 0.78 to 1.08N•m)
Mountable with a DIN rail in 6 orientations
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
y RAV1.25-3 (compliant with JIS C 2805)
[Applicable wire size: 0.3 to 1.25mm2]
Applicable solderless terminal
y V2-MS3, RAP2-3SL, TGV2-3N
[Applicable wire size: 1.25 to 2.0mm2]
Accessory User’s manual
5-5 5-5
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
TB2 DB
1 DA TB3 DG
2 DB
3 DG
TB4 SLD
Insulation
4 SLD TB5 +24V
5 +24V
TB6 (FG)
6 FG
7 24G TB7 24G
Module power supply
TB8 Y0
Load
8 Y0 TB9 COM
9 COM
TB10 Y1
10 Y1
11 COM TB11 COM
12 Y2 TB12 Y2
13 COM
14 Y3 TB13 COM
15 COM TB14 Y3
16 Y4
TB15 COM
17 COM
18 Y5 TB16 Y4
19 COM TB17 COM
20 Y6
21 COM TB18 Y5
Load
22 Y7 TB19 COM
23 COM
24 DC24V
TB20 Y6
25 DC24G TB21 COM
External power supply for output part
TB22 Y7
TB23 COM
Constant-voltage circuit TB24 DC24V
TB25 DC24G
5-6 5-6
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
DC24G
External power supply for Voltage 10.2 to 26.4VDC (ripple ratio: within 5%)
DC24V
B RATE
40 20 10 8 4 2 1 4 2 1
COM
output part Current 17.8mA or lower (TYP. 24VDC/common), excluding external load current
Y7
COM
Surge suppressor Zener diode
STATION NO.
Y6
Wiring method for common 8 points/common (2-wire, terminal block type)
COM
Number of occupied stations 32-point assignment/station (8 points used)
Y5
COM
Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
ON
Module power supply
Y4
Current 45mA or lower (at 24VDC and all points ON)
COM
Y3
Noise voltage 500Vp-p, noise width 1µs,
COM
Noise immunity
noise frequency 25 to 60Hz (DC type noise simulator condition)
Y2
COM
AJ65SBTB2-8T1
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
Y1
10MΩ or higher between all DC external terminals and ground (500VDC
COM
Insulation resistance
insulation resistance tester)
Y0
Y0 1 2 3 4 5 6 7
Protection degree IP2X
Weight 0.18kg
(FG)
24G
7-point two-piece terminal block
DA DG +24V
Communication part, [Transmission circuit, module power supply, FG]
SLD
module power supply part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
External
DB
Applicable solderless terminal: 2 or less
connection
18-point direct-mount terminal block
system
I/O power supply part, [I/O power supply, I/O signal]
I/O part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
Applicable solderless terminal: 2 or less
M4 screw with plain washer finished round
Module mounting screw (tightening torque range: 0.78 to 1.08N•m)
Mountable with a DIN rail in 6 orientations
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
y RAV1.25-3 (compliant with JIS C 2805)
[Applicable wire size: 0.3 to 1.25mm2]
Applicable solderless terminal
y V2-MS3, RAP2-3SL, TGV2-3N
[Applicable wire size: 1.25 to 2.0mm2]
Accessory User’s manual
5-7 5-7
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
TB2 DB
TB3 DG
1 DA
2 DB TB4 SLD
3 DG
Insulation TB5 +24V
4 SLD
TB6 (FG)
5 +24V
6 FG TB7 24G
7 24G
Module power supply TB8 Y0
Load TB9 COM
8 Y0
TB10 Y1
9 COM
10 Y1 TB11 COM
11 COM
TB12 Y2
12 Y2
13 COM TB13 COM
14 Y3 TB14 Y3
15 COM
16 Y4 TB15 COM
17 COM TB16 Y4
18 Y5
TB17 COM
19 COM
20 Y6 TB18 Y5
Load 21 COM TB19 COM
22 Y7
23 COM TB20 Y6
24 DC24V TB21 COM
25 DC24G
External power supply for output part TB22 Y7
5-8 5-8
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
COM-
External Power supply for Voltage 10.2 to 26.4VDC (ripple ratio: within 5%)
CTL+
B RATE
40 20 10 8 4 2 1 4 2 1
YF
output part Current 30mA or lower (TYP. 24VDC/common), excluding external load current
YE
YD
Surge suppressor Zener diode
STATION NO.
YC
Wiring method for common 16 points/common (1-wire, terminal block type)
YB
Number of occupied stations 32-point assignment/station (16 points used)
YA
Y9
Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
ON
Module power supply
Y8
Current 50mA or lower (at 24VDC and all points ON)
Y7
Y6
Noise voltage 500Vp-p, noise width 1µs,
Y8 9 A B C D E F
Noise immunity
Y5
noise frequency 25 to 60Hz (DC type noise simulator condition)
Y4
AJ65SBTB1-16T
Y3
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
Y2
10MΩ or higher between all DC external terminals and ground (500VDC
Y1
Insulation resistance
insulation resistance tester)
Y0
Y0 1 2 3 4 5 6 7
Protection degree IP2X
Weight 0.18kg
(FG)
24G
7-point two-piece terminal block
DA DG +24V
Communication part, [Transmission circuit, module power supply, FG]
SLD
module power supply part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
External
DB
Applicable solderless terminal: 2 or less
connection
18-point direct-mount terminal block
system
I/O power supply part, [I/O power supply, I/O signal]
I/O part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
Applicable solderless terminal: 2 or less
M4 screw with plain washer finished round
Module mounting screw (tightening torque range: 0.78 to 1.08N•m)
Mountable with a DIN rail in 6 orientations
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
y RAV1.25-3 (compliant with JIS C 2805)
[Applicable wire size: 0.3 to 1.25mm2]
Applicable solderless terminal
y V2-MS3, RAP2-3SL, TGV2-3N
[Applicable wire size: 1.25 to 2.0mm2]
Accessory User’s manual
5-9 5-9
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
TB2 DB
1 DA
2 DB TB3 DG
3 DG Insulation TB4 SLD
4 SLD
5 +24V TB5 +24V
6 FG
7 24G
TB6 (FG)
Module power supply
TB7 24G
Load
8 Y0 TB8 Y0
9 Y1
10 Y2
TB9 Y1
11 Y3 TB10 Y2
12 Y4
13 Y5 TB11 Y3
14 Y6 TB12 Y4
15 Y7
16 Y8 TB13 Y5
17 Y9
TB14 Y6
18 YA
19 YB TB15 Y7
20 YC
TB16 Y8
21 YD
Load 22 YE TB17 Y9
23 YF
24 CTL+
TB18 YA
External power supply for output part
25 COM- TB19 YB
TB20 YC
Load power supply Constant-voltage circuit
TB21 YD
TB22 YE
Load TB23 YF
External power supply for output TB24 CTL+
part and load power supply
24 CTL+
(common) TB25 COM-
25 COM-
5 - 10 5 - 10
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
COM-
External power supply for Voltage 10.2 to 26.4VDC (ripple ratio: within 5%)
CTL+
B RATE
40 20 10 8 4 2 1 4 2 1
YF
output part Current 30mA or lower (TYP. 24VDC/common), excluding external load current
YE
YD
Surge suppressor Zener diode
STATION NO.
YC
Wiring method for common 16 points/common (1-wire, terminal block type )
YB
Number of occupied stations 32-point assignment/station (16 points used)
YA
Y9
Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
ON
Module power supply
Y8
Current 50mA or lower (at 24VDC and all points ON)
Y7
Y6
Noise voltage 500Vp-p, noise width 1µs,
Y8 9 A B C D E F
Noise immunity
Y5
noise frequency 25 to 60Hz (DC type noise simulator condition)
Y4
AJ65SBTB1-16T1
Y3
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
Y2
10MΩ or higher between all DC external terminals and ground (500VDC
Y1
Insulation resistance
insulation resistance tester)
Y0
Y0 1 2 3 4 5 6 7
Protection degree IP2X
Weight 0.18kg
(FG)
24G
7-point two-piece terminal block
DA DG +24V
Communication part, [Transmission circuit, module power supply, FG]
SLD
module power supply part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
External
DB
Applicable solderless terminal: 2 or less
connection
18-point direct-mount terminal block
system
I/O power supply part, [I/O power supply, I/O signal]
I/O part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
Applicable solderless terminal: 2 or less
M4 screw with plain washer finished round
Module mounting screw (tightening torque range: 0.78 to 1.08N•m)
Mountable with a DIN rail in 6 orientations
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
y RAV1.25-3 (compliant with JIS C 2805)
[Applicable wire size: 0.3 to 1.25mm2]
Applicable solderless terminal
y V2-MS3, RAP2-3SL, TGV2-3N
[Applicable wire size: 1.25 to 2.0mm2]
Accessory User’s manual
5 - 11 5 - 11
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
TB2 DB
1 DA
2 DB TB3 DG
3 DG Insulation TB4 SLD
4 SLD
5 +24V TB5 +24V
6 FG TB6 (FG)
7 24G
Module power supply TB7 24G
Load TB8 Y0
8 Y0
9 Y1 TB9 Y1
10 Y2
11 Y3 TB10 Y2
12 Y4 TB11 Y3
13 Y5
14 Y6 TB12 Y4
15 Y7 TB13 Y5
16 Y8
17 Y9 TB14 Y6
18 YA TB15 Y7
19 YB
20 YC TB16 Y8
21 YD TB17 Y9
Load 22 YE
23 YF TB18 YA
24 CTL+ TB19 YB
External power supply for output part
25 COM-
TB20 YC
TB21 YD
Load power supply Constant-voltage circuit
TB22 YE
Load
External power supply for output TB23 YF
part and load power supply TB24 CTL+
24 CTL+ (common)
25 COM- TB25 COM-
5 - 12 5 - 12
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
DC24G
Protection function Overload protection, overvoltage protection, overheat protection
DC24V
40 20 10 8 4 2 1 4 2 1
B RATE
COM
OFF→ON 0.5ms or less
YF
Response time
COM
STATION NO.
ON→OFF 1.5ms or less (resistive load)
YE
COM
External power supply for Voltage 10.2 to 26.4VDC (ripple ratio: within 5%)
YD
COM
output part Current 24.2mA or lower (TYP. 24VDC/common), excluding external load current
ON
YC
COM
Surge suppressor Zener diode
YB
Wiring method for common 16 points/common (2-wire, terminal block type)
COM
YA
Number of occupied stations 32-point assignment/station (16 points used)
COM
Y9
Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
COM
Module power supply
Current 55mA or lower (at 24VDC and all points ON)
Y8
COM
Noise voltage 500Vp-p, noise width 1µs,
Y7
Noise immunity
COM
noise frequency 25 to 60Hz (DC type noise simulator condition)
Y6
COM
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
Y5
COM
10MΩ or higher between all DC external terminals and ground (500VDC insulation
Insulation resistance
Y4
resistance tester)
COM
Y3
Protection degree IP2X
COM
Y8 9 A B C D E F
Weight 0.25kg
Y2
COM
AJ65SBTB2-16T
7-point two-piece terminal block
Y1
COM
Communication part, [Transmission circuit, module power supply, FG]
Y0
PW L RUN L ERR. Y0 1 2 3 4 5 6 7
module power supply part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
External
Applicable solderless terminal: 2 or less
(FG)
24G
connection
34-point direct-mount terminal block DG +24V
system SLD
I/O power supply part, [I/O power supply, I/O signal]
I/O part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
DB
DA
5 - 13 5 - 13
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
TB2 DB
TB3 DG
1 DA
TB4 SLD
2 DB
3 DG Insulation
TB5 +24V
4 SLD TB6 (FG)
5 +24V
TB7 24G
6 FG
7 24G TB8 Y0
Module power supply TB9 COM
Load
8 Y0 TB10 Y1
9 COM TB11 COM
10 Y1
TB12 Y2
11 COM
12 Y2 TB13 COM
13 COM TB14 Y3
14 Y3
TB15 COM
15 COM
16 Y4 TB16 Y4
17 COM TB17 COM
18 Y5
TB18 Y5
19 COM
20 Y6 TB19 COM
21 COM TB20 Y6
22 Y7
TB21 COM
23 COM
24 Y8 TB22 Y7
25 COM TB23 COM
26 Y9
TB24 Y8
27 COM
28 YA TB25 COM
29 COM TB26 Y9
30 YB
TB27 COM
31 COM
32 YC TB28 YA
33 COM TB29 COM
34 YD
TB30 YB
35 COM
36 YE TB31 COM
Load 37 COM TB32 YC
38 YF
TB33 COM
39 COM
40 DC24V TB34 YD
41 DC24G TB35 COM
External power supply for output part
TB36 YE
TB37 COM
Constant-voltage circuit TB38 YF
TB39 COM
TB40 DC24V
TB41 DC24G
5 - 14 5 - 14
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
DC24G
Protection function None
DC24V
B RATE
40 20 10 8 4 2 1 4 2 1
COM
OFF→ON 0.5ms or less
YF
Response time
COM
STATION NO.
ON→OFF 1.5ms or less (resistive load)
YE
COM
External power supply for Voltage 10.2 to 26.4VDC (ripple ratio: within 5%)
YD
COM
output part Current 24.2mA or lower (TYP. 24VDC/common), excluding external load current
ON
YC
COM
Surge suppressor Zener diode
YB
Wiring method for common 16 points/common (2-wire, terminal block type)
COM
YA
Number of occupied stations 32-point assignment/station (16 points used)
COM
Y9
Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
COM
Module power supply
Current 55mA or lower (at 24VDC and all points ON)
Y8
COM
Noise voltage 500Vp-p, noise width 1µs,
Y7
Noise immunity
COM
noise frequency 25 to 60Hz (DC type noise simulator condition)
Y6
COM
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
Y5
COM
10MΩ or higher between all DC external terminals and ground (500VDC insulation
Insulation resistance
Y4
resistance tester)
COM
Y3
Protection degree IP2X
COM
Y8 9 A B C D E F
Y2
Weight 0.25kg
AJ65SBTB2-16T1
COM
7-point two-piece terminal block
Y1
COM
Communication part, [Transmission circuit, module power supply, FG]
Y0
PW L RUN L ERR. Y0 1 2 3 4 5 6 7
module power supply part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
External
Applicable solderless terminal: 2 or less
(FG)
24G
connection
34-point direct-mount terminal block +24V
system SLD
I/O power supply part, [I/O power supply, I/O signal]
DG
5 - 15 5 - 15
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
TB2 DB
TB3 DG
1 DA TB4 SLD
2 DB
3 DG TB5 +24V
Insulation
4 SLD TB6 (FG)
5 +24V TB7 24G
6 FG
7 24G TB8 Y0
Module power supply TB9 COM
Load
8 Y0 TB10 Y1
9 COM TB11 COM
10 Y1
TB12 Y2
11 COM
12 Y2 TB13 COM
13 COM TB14 Y3
14 Y3
TB15 COM
15 COM
16 Y4 TB16 Y4
17 COM TB17 COM
18 Y5
TB18 Y5
19 COM
20 Y6 TB19 COM
21 COM TB20 Y6
22 Y7
TB21 COM
23 COM
24 Y8 TB22 Y7
25 COM TB23 COM
26 Y9
TB24 Y8
27 COM
28 YA TB25 COM
29 COM TB26 Y9
30 YB
TB27 COM
31 COM
32 YC TB28 YA
33 COM TB29 COM
34 YD
35 COM
TB30 YB
36 YE TB31 COM
37 COM TB32 YC
Load
38 YF
39 COM
TB33 COM
40 DC24V TB34 YD
41 DC24G TB35 COM
External power supply for output part
TB36 YE
TB37 COM
Constant-voltage circuit TB38 YF
TB39 COM
TB40 DC24V
TB41 DC24G
5 - 16 5 - 16
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
Y1F COM-
Y1E CTL+
B RATE
40 20 10 8 4 2 1 4 2 1
Max. voltage drop at ON 0.3VDC or lower (TYP.) 0.5A, 0.6VDC or lower (MAX.) 0.5A
Output type Sink type
Y1D
STATION NO.
Protection function Overload protection, overvoltage protection, overheat protection
Y1C
Y1B
OFF→ON 0.5ms or less
Response time
Y1A
ON→OFF 1.5ms or less (resistive load)
Y19
Y18
External power supply for Voltage 10.2 to 26.4VDC (ripple ratio: within 5%)
ON
Y17
output part Current 50mA or lower (TYP. 24VDC/common), excluding external load current
Y16
Y15
Surge suppressor Zener diode
Y14
Wiring method for common 32 points/common (1-wire, terminal block type)
Y13
Number of occupied stations 32-point assignment/station (32 points used)
Y12
Y18 19 1A1B 1C1D1E 1F
Y11
Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
Y10
Module power supply
Current 65mA or lower (at 24VDC and all points ON)
YF
YE
Noise voltage 500Vp-p, noise width 1µs,
YD
Noise immunity
noise frequency 25 to 60Hz (DC type noise simulator condition)
YC
Y10 11 12 13 14 15 16 17
YB
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
YA
10MΩ or higher between all DC external terminals and ground (500VDC
Y9
Insulation resistance
insulation resistance tester)
Y8
Y7
Protection degree IP2X
Y6
Y8 9 A B C D E F
Weight 0.25kg
Y5
Y4
7-point two-piece terminal block
AJ65SBTB1-32T
Y3
Communication part, [Transmission circuit, module power supply, FG]
Y2
Y1
module power supply part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
External
Applicable solderless terminal: 2 or less Y0
PW L RUN L ERR. Y0 1 2 3 4 5 6 7
connection
34-point direct-mount terminal block
system
(FG)
24G
5 - 17 5 - 17
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
TB2 DB
TB3 DG
1 DA
2 DB TB4 SLD
3 DG Insulation TB5 +24V
4 SLD
TB6 (FG)
5 +24V
6 FG TB7 24G
7 24G
Module power supply TB8 Y0
Load TB9 Y1
8 Y0
9 Y1
TB10 Y2
10 Y2 TB11 Y3
11 Y3
12 Y4
TB12 Y4
13 Y5 TB13 Y5
14 Y6
TB14 Y6
15 Y7
16 Y8 TB15 Y7
17 Y9 TB16 Y8
18 YA
19 YB TB17 Y9
20 YC TB18 YA
21 YD
22 YE
TB19 YB
23 YF TB20 YC
24 Y10
TB21 YD
25 Y11
26 Y12 TB22 YE
27 Y13 TB23 YF
28 Y14
29 Y15 TB24 Y10
30 Y16 TB25 Y11
31 Y17
32 Y18
TB26 Y12
33 Y19 TB27 Y13
34 Y1A
TB28 Y14
35 Y1B
36 Y1C TB29 Y15
37 Y1D
TB30 Y16
38 Y1E
Load
39 Y1F TB31 Y17
External power supply for output part 40 CTL+ TB32 Y18
41 COM-
TB33 Y19
TB34 Y1A
Load power supply
Constant-voltage circuit TB35 Y1B
Load TB36 Y1C
External power supply for output
part and load power supply TB37 Y1D
40 CTL+ (common) TB38 Y1E
41 COM-
TB39 Y1F
TB40 CTL+
TB41 COM-
5 - 18 5 - 18
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
Y1F COM-
Max. voltage drop at ON 0.3VDC or lower (TYP.) 0.5A, 0.6VDC or lower (MAX.) 0.5A
Y1E CTL+
B RATE
40 20 10 8 4 2 1 4 2 1
Output type Sink type
Protection function None
Y1D
STATION NO.
Y1C
OFF→ON 0.5ms or less
Y1B
Response time
ON→OFF 1.5ms or less (resistive load)
Y1A
Y19
External power supply for Voltage 10.2 to 26.4VDC (ripple ratio: within 5%)
Y18
ON
output part
Y17
Current 50mA or lower (TYP. 24VDC/common), excluding external load current
Y16
Surge suppressor Zener diode
Y15
Y14
Wiring method for common 32 points/common (1-wire, terminal block type)
Y13
Number of occupied stations 32-point assignment/station (32 points used)
Y12
Y10 11 12 13 14 15 16 17 Y18 19 1A1B1C1D1E 1F
Y11
Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
Module power supply
Y10
Current 65mA or lower (at 24VDC and all points ON)
YF
YE
Noise voltage 500Vp-p, noise width 1µs,
Noise immunity
YD
noise frequency 25 to 60Hz (DC type noise simulator condition)
YC
YB
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
YA
10MΩ or higher between all DC external terminals and ground (500VDC
Y9
Insulation resistance
Y8
insulation resistance tester)
Y7
Protection degree IP2X
Y6
Y8 9 A B C D E F
Y5
Weight 0.25kg
Y4
AJ65SBTB1-32T1
7-point two-piece terminal block
Y3
Y2
Communication part, [Transmission circuit, module power supply, FG]
Y1
module power supply part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
Y0
External
PW L RUN L ERR. Y0 1 2 3 4 5 6 7
5 - 19 5 - 19
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
TB2 DB
TB3 DG
1 DA
2 DB
TB4 SLD
3 DG Insulation TB5 +24V
4 SLD
5 +24V
TB6 (FG)
6 FG TB7 24G
7 24G
Module power supply TB8 Y0
Load TB9 Y1
8 Y0
9 Y1 TB10 Y2
10 Y2 TB11 Y3
11 Y3
12 Y4 TB12 Y4
13 Y5 TB13 Y5
14 Y6
15 Y7 TB14 Y6
16 Y8 TB15 Y7
17 Y9
18 YA TB16 Y8
19 YB TB17 Y9
20 YC
21 YD TB18 YA
22 YE TB19 YB
23 YF
24 Y10 TB20 YC
25 Y11 TB21 YD
26 Y12
27 Y13
TB22 YE
28 Y14 TB23 YF
29 Y15
30 Y16
TB24 Y10
31 Y17 TB25 Y11
32 Y18
33 Y19
TB26 Y12
34 Y1A TB27 Y13
35 Y1B
36 Y1C
TB28 Y14
37 Y1D TB29 Y15
38 Y1E
Load TB30 Y16
39 Y1F
External power supply for output part 40 CTL+ TB31 Y17
41 COM-
TB32 Y18
TB33 Y19
Load power supply Constant-voltage circuit TB34 Y1A
TB35 Y1B
Load
TB36 Y1C
External power supply for output
part and load power supply TB37 Y1D
40 CTL+
(common) TB38 Y1E
41 COM-
TB39 Y1F
TB40 CTL+
TB41 COM-
5 - 20 5 - 20
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
CTL-
Surge suppressor Zener diode
COM+
B RATE
40 20 10 8 4 2 1 4 2 1
Wiring method for common 8 points/common (1-wire, terminal block type)
Y7
Y6
Number of occupied stations 32-point assignment/station (8 points used)
Y5
STATION NO.
Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
Y4
Module power supply
Y3
Current 35mA or lower (at 24VDC and all points ON)
Y2
Noise voltage 500Vp-p, noise width 1µs,
Y1
Noise immunity
ON
Y0
noise frequency 25 to 60Hz (DC type noise simulator condition)
Y0 1 2 3 4 5 6 7
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
A J65SBTB1-8TE
24G
(FG)
10MΩ or higher between all DC external terminals and ground (500VDC
Insulation resistance
insulation resistance tester)
DA DG +24V
Weight 0.14kg
SLD
7-point two-piece terminal block
DB
Communication part, [Transmission circuit, module power supply, FG]
module power supply part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
External
Applicable solderless terminal: 2 or less
connection
10-point direct-mount terminal block
system
I/O power supply part, [I/O power supply, I/O signal]
I/O part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
Applicable solderless terminal: 2 or less
M4 screw with plain washer finished round
Module mounting screw (tightening torque range: 0.78 to 1.08N•m)
Mountable with a DIN rail in 6 orientations
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
y RAV1.25-3 (compliant with JIS C 2805)
[Applicable wire size: 0.3 to 1.25mm2]
Applicable solderless terminal
y V2-MS3, RAP2-3SL, TGV2-3N
[Applicable wire size: 1.25 to 2.0mm2]
Accessory User’s manual
5 - 21 5 - 21
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
1 DA TB2 DB
2 DB
TB3 DG
3 DG
Insulation
4 SLD TB4 SLD
5 +24V TB5 +24V
6 FG
TB6 (FG)
7 24G
Module power supply TB7 24G
Load TB8 Y0
8 Y0
9 Y1 TB9 Y1
10 Y2 TB10 Y2
11 Y3
12 Y4
TB11 Y3
13 Y5 TB12 Y4
Load 14 Y6 TB13 Y5
15 Y7
16 COM+
TB14 Y6
Load power supply 17 CTL- TB15 Y7
External power supply for output part TB16 COM+
TB17 CTL-
Constant-voltage circuit
Load
External power supply for output
part and load power supply
16 COM+ (common)
17 CTL-
5 - 22 5 - 22
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
CTL-
YE COM+
B RATE
40 20 10 8 4 2 1 4 2 1
External power supply for Voltage 10.2 to 26.4VDC (ripple ratio: within 5%)
YF
output part Current 30mA or lower (TYP. 24VDC/common), excluding external load current
YD
STATION NO.
Surge suppressor Zener diode
YC
YB
Wiring method for common 16 points/common (1-wire, terminal block type )
YA
Number of occupied stations 32-point assignment/station (16 points used)
Y9
ON
Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
Y8
Module power supply
Y7
Current 50mA or lower (at 24VDC and all points ON)
Y6
Y8 9 A B C D E F
Y5
Noise voltage 500Vp-p, noise width 1µs,
Noise immunity
Y4
noise frequency 25 to 60Hz (DC type noise simulator condition)
AJ65SBTB1-16TE
Y3
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
Y2
Y1
10MΩ or higher between all DC external terminals and ground (500VDC
Insulation resistance
Y0
insulation resistance tester)
Y0 1 2 3 4 5 6 7
Weight 0.18kg
(FG)
24G
7-point two-piece terminal block
Communication part, [Transmission circuit, module power supply, FG]
DA DG +24V
module power supply part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
SLD
External
Applicable solderless terminal: 2 or less
DB
connection
18-point direct-mount terminal block
system
I/O power supply part, [I/O power supply, I/O signal]
I/O part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
Applicable solderless terminal: 2 or less
M4 screw with plain washer finished round
Module mounting screw (tightening torque range: 0.78 to 1.08N•m)
Mountable with a DIN rail in 6 orientations
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
y RAV1.25-3 (compliant with JIS C 2805)
[Applicable wire size: 0.3 to 1.25mm2]
Applicable solderless terminal
y V2-MS3, RAP2-3SL, TGV2-3N
[Applicable wire size: 1.25 to 2.0mm2]
Accessory User’s manual
5 - 23 5 - 23
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
1 DA TB2 DB
2 DB
3 DG
TB3 DG
Insulation
4 SLD TB4 SLD
5 +24V
TB5 +24V
6 FG
7 24G TB6 (FG)
Module power supply
TB7 24G
Load
8 Y0 TB8 Y0
9 Y1
TB9 Y1
10 Y2
11 Y3 TB10 Y2
12 Y4 TB11 Y3
13 Y5
TB12 Y4
14 Y6
15 Y7 TB13 Y5
16 Y8
TB14 Y6
17 Y9
18 YA TB15 Y7
19 YB TB16 Y8
20 YC
21 YD
TB17 Y9
Load 22 YE TB18 YA
23 YF
TB19 YB
Load power supply 24 COM
25 CTL TB20 YC
External power supply for output part TB21 YD
TB22 YE
TB23 YF
Constant-voltage circuit TB24 COM+
Load TB25 CTL-
External power supply for output
part and load power supply
24 COM (common)
25 CTL-
5 - 24 5 - 24
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
COM1- COM1- COM1- COM1- COM1- COM1- CTL1- COM1+ COM2- COM2- COM2- COM2- COM2- COM2- CTL2- COM2+ NC
NC
B RATE
40 20 10 8 4 2 1 4 2 1
Output type Source type
YE YF
Protection function None
STATION NO.
OFF→ON 0.5ms or less
Response time
ON→OFF 1.5ms or less (resistive load)
YD
External power supply for Voltage 10.2 to 26.4VDC (ripple ratio: within 5%)
YC
ON
output part Current 10mA or lower (TYP. 24VDC/common), excluding external load current
YB
Surge suppressor Zener diode
Wiring method for common 8 points/common (1-wire, terminal block type)
YA
Number of occupied stations 32-point assignment/station (16 points used)
Y9
Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
Module power supply
Y8
Current 45mA or lower (at 24VDC and all points ON)
Y7
Noise voltage 500Vp-p, noise width 1µs,
Noise immunity
noise frequency 25 to 60Hz (DC type noise simulator condition)
Y6
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
Y5
10MΩ or higher between all DC external terminals and ground (500VDC
Insulation resistance
Y4
insulation resistance tester)
Protection degree IP2X
Y3
Y8 9 A B C D E F
Weight 0.26kg
Y2
A J65SBTB1B-16TE1
7-point two-piece terminal block
Y1
Communication part, [Transmission circuit, module power supply, FG]
module power supply part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
Y0
External
PW L RUN L ERR.Y0 1 2 3 4 5 6 7
system
I/O power supply part, [I/O power supply, I/O signal]
DA DG +24V
5 - 25 5 - 25
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
TB2 DB
1 DA TB3 DG
2 DB
TB4 SLD
3 DG
Insulation TB5 +24V
4 SLD
5 +24V TB6 (FG)
6 FG TB7 24G
Module power supply 7 24G TB8 Y0
TB9 COM1-
Load TB10 Y1
8 Y0
9 COM1- TB11 COM1-
10 Y1 TB12 Y2
11 COM1- TB13 COM1-
12 Y2 TB14 Y3
13 COM1-
TB15 COM1-
14 Y3
15 COM1-
TB16 Y4
16 Y4 TB17 COM1-
17 COM1- TB18 Y5
18 Y5 TB19 COM1-
19 COM1- TB20 Y6
20 Y6
TB21 CTL1-
Load 21 CTL1-
TB22 Y7
22 Y7
External power supply TB23 COM1+
23 COM1+
for output part and Load
TB24 Y8
24 Y8
load power supply Constant-voltage circuit
25 COM2- TB25 COM2-
(common)
26 Y9 TB26 Y9
27 COM2-
TB27 COM2-
28 YA
TB28 YA
29 COM2-
30 YB TB29 COM2-
31 COM2- TB30 YB
32 YC TB31 COM2-
33 COM2- TB32 YC
34 YD TB33 COM2-
35 COM2-
TB34 YD
36 YE
37 CTL2-
TB35 COM2-
Load
38 YF TB36 YE
39 COM2+ TB37 CTL2-
External power supply for output part 40 Empty TB38 YF
and load power supply (common) 41 Empty Constant-voltage circuit TB39 COM2+
TB40 Empty
TB41 Empty
5 - 26 5 - 26
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
STATION NO.
OFF→ON 0.5ms or less
Response time
ON→OFF 1.5ms or less (resistive load)
External power supply for Voltage 10.2 to 26.4VDC (ripple ratio: within 5%)
ON
Y13 Y15
Wiring method for common 32 points/common (1-wire, terminal block type)
Number of occupied stations 32-point assignment/station (32 points used)
Y10 Y12
Y1819 1A 1B 1C 1D1E 1F
Y11
Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
Module power supply
Current 60mA or lower (at 24VDC and all points ON)
YF
YE
Noise voltage 500Vp-p, noise width 1µs,
Noise immunity
YD
noise frequency 25 to 60Hz (DC type noise simulator condition)
YC
Y1011 12 13 14 15 16 17
YB
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
YA
10MΩ or higher between all DC external terminals and ground (500VDC
Y9
Insulation resistance
Y8
insulation resistance tester)
Y7
Protection degree IP2X
Y6
Y8 9 A B C D E F
Y5
Weight 0.26kg
Y4
7-point two-piece terminal block
Y3
A J65SBTB1-32TE1
Y2
Communication part, [Transmission circuit, module power supply, FG]
Y1
module power supply part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
Y0
External
PW L RUN L ERR.Y0 1 2 3 4 5 6 7
system
I/O power supply part, [I/O power supply, I/O signal]
DA DG +24V
5 - 27 5 - 27
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
1 DA TB2 DB
2 DB TB3 DG
3 DG Insulation TB4 SLD
4 SLD
5 +24V
TB5 +24V
6 FG TB6 (FG)
7 24G TB7 24G
Module power supply
TB8 Y0
Load
8 Y0 TB9 Y1
9 Y1
TB10 Y2
10 Y2
11 Y3 TB11 Y3
12 Y4 TB12 Y4
13 Y5 TB13 Y5
14 Y6
TB14 Y6
15 Y7
16 Y8 TB15 Y7
17 Y9 TB16 Y8
18 YA TB17 Y9
19 YB
TB18 YA
20 YC
21 YD TB19 YB
22 YE TB20 YC
23 YF
TB21 YD
24 Y10
25 Y11 TB22 YE
26 Y12 TB23 YF
27 Y13 TB24 Y10
28 Y14
TB25 Y11
29 Y15
30 Y16 TB26 Y12
31 Y17 TB27 Y13
32 Y18 TB28 Y14
33 Y19
34 Y1A
TB29 Y15
35 Y1B TB30 Y16
36 Y1C TB31 Y17
37 Y1D
TB32 Y18
Load 38 Y1E
39 Y1F TB33 Y19
40 COM+ TB34 Y1A
Load power supply 41 CTL- TB35 Y1B
Constant-voltage circuit
TB36 Y1C
External power supply for output part
TB37 Y1D
TB38 Y1E
Load
External power supply for output TB39 Y1F
part and load power supply TB40 COM+
40 COM+ (common) TB41 CTL-
41 CTL-
5 - 28 5 - 28
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
Y0 1 2 3 4 5 6 7
Y7 COMA
Wiring method for common 8 points/common (2-wire, terminal block type)
Number of occupied stations 32-point assignment/station (8 points used)
Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
Y6
Module power supply
Current 85mA or lower (at 24VDC and all points ON)
Y5
Noise voltage: 1500Vp-p (AC type), 500Vp-p (DC type), noise width 1µs,
Y4
noise frequency 25 to 60Hz (noise simulator condition)
Noise immunity
Fast transient/burst immunity test
Y3
IEC61000-4-4:1kV
Y2
B RATE
40 20 10 8 4 2 1 4 2 1
2830VACrms for 3 cycles between all AC external terminals and ground
Withstand voltage (2000m above sea level)
Y1
STATION NO.
500VAC for 1 minute between all DC external terminals and ground
Y0
10MΩ or higher between all AC external terminals and ground (500VDC
insulation resistance tester)
Insulation resistance
(FG)
10MΩ or higher between all DC external terminals and ground (500VDC
24G
ON
A J65SBTB2N-8R
5 - 29 5 - 29
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
TB2 DB
1 DA
2 DB TB3 DG
3 DG TB4 SLD
Insulation
4 SLD TB5 +24V
5 +24V TB6 (FG)
6 FG TB7 24G
7 24G TB8 Y0
Module power supply
TB9 COM B
Load
8 Y0 TB10 Y1
9 COM B TB11 COM B
10 Y1 TB12 Y2
11 COM B TB13 COM B
12 Y2 TB14 Y3
13 COM B
TB15 COM B
14 Y3
TB16 Y4
15 COM B
TB17 COM B
16 Y4
17 COM B
TB18 Y5
18 Y5 TB19 COM B
19 COM B TB20 Y6
20 Y6 TB21 COM B
Load
21 COM B TB22 Y7
22 Y7 TB23 COM B
23 COM B TB24 COM A
24 COM A
TB25 COM B
25 COM B
100/200VAC or 24VDC
All COM B terminals are connected inside the module (shared common).
5 - 30 5 - 30
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB
200VAC 1A, 240VAC 0.5A (cosφ=0.35): 100 thousand times or more
Y8 9 A B C D E F
COMA
24VDC 1A, 100VDC 0.1A (L/R=7ms): 100 thousand times or more
YF
Max. switching frequency 3600 times/hour
YE
Surge suppressor None
PW L RUN L ERR. Y0 1 2 3 4 5 6 7
YD
Wiring method for common 16 points/common (2-wire, terminal block type)
YC
Number of occupied stations 32-point assignment/station (16 points used)
Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
YB
Module power supply
Current 120mA or lower (at 24VDC and all points ON)
YA
Noise voltage: 1500Vp-p (AC type), 500Vp-p (DC type), noise width 1µs,
Y9
noise frequency 25 to 60Hz (noise simulator condition)
Noise immunity
Y8
Fast transient/burst immunity test
Y7
IEC 61000-4-4:1kV
Y6
2830VACrms for 3 cycles between all AC external terminals and ground (2000m
Withstand voltage above sea level)
Y5
500VAC for 1 minute between all DC external terminals and ground
Y4
10MΩ or higher between all AC external terminals and ground (500VDC insulation
Y3
resistance tester)
B RATE
40 20 10 8 4 2 1 4 2 1
Insulation resistance
Y2
10MΩ or higher between all DC external terminals and ground (500VDC insulation
Y1
resistance tester)
STATION NO.
Y0
Weight 0.35kg
7-point two-piece terminal block (FG)
24G
ON
DA DG +24V
module power supply part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
External
SLD
5 - 31 5 - 31
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
1 DA TB2 DB
2 DB TB3 DG
3 DG
Insulation TB4 SLD
4 SLD TB5 +24V
5 +24V
TB6 (FG)
6 FG
7 24G
TB7 24G
Module power supply TB8 Y0
Load TB9 COM B
8 Y0
TB10 Y1
9 COM B
10 Y1 TB11 COM B
11 COM B TB12 Y2
12 Y2 TB13 COM B
13 COM B TB14 Y3
14 Y3 TB15 COM B
15 COM B
TB16 Y4
16 Y4
17 COM B TB17 COM B
18 Y5 TB18 Y5
19 COM B TB19 COM B
20 Y6 TB20 Y6
21 COM B
TB21 COM B
22 Y7
23 COM B
TB22 Y7
24 Y8 TB23 COM B
25 COM B TB24 Y8
26 Y9 TB25 COM B
27 COM B TB26 Y9
28 YA
TB27 COM B
29 COM B
30 YB TB28 YA
31 COM B TB29 COM B
32 YC TB30 YB
33 COM B TB31 COM B
34 YD TB32 YC
35 COM B
TB33 COM B
36 YE
37 COM B TB34 YD
Load
38 YF TB35 COM B
39 COM B TB36 YE
40 COM A TB37 COM B
41 COM B
TB38 YF
External load power supply TB39 COM B
TB40 COM A
TB41 COM B
100/200VAC or 24VDC
All COM B terminals are connected inside the module (shared common).
5 - 32 5 - 32
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
Y7 COMA
Wiring method for common 8 points/common (2-wire, terminal block type)
Number of occupied stations 32-point assignment/station (8 points used)
Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
Module power supply
Y6
Current 55mA or lower (at 24VDC and all points ON)
Y5
Noise voltage: 1500Vp-p (AC type), 500Vp-p (DC type), noise width 1µs,
noise frequency 25 to 60Hz (noise simulator condition)
Y4
Noise immunity
Fast transient/burst immunity test
Y3
IEC61000-4-4:1kV
2830VACrms for 3 cycles between all AC external terminals and ground
Y2
B RATE
40 20 10 8 4 2 1 4 2 1
Withstand voltage (2000m above sea level)
Y1
500VAC for 1 minute between all DC external terminals and ground
STATION NO.
10MΩ or higher between all AC external terminals and ground (500VDC
Y0
insulation resistance tester)
Insulation resistance
10MΩ or higher between all DC external terminals and ground (500VDC
(FG)
24G
insulation resistance tester) ON
AJ65SBTB2N-8S
+24V
Weight 0.25kg
7-point two-piece terminal block SLD
DA DG
module power supply part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
External
Applicable solderless terminal: 2 or less
connection
18-point direct-mount terminal block
system
I/O power supply part, [I/O power supply, I/O signal]
I/O part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
Applicable solderless terminal: 2 or less
M4 screw with plain washer finished round
Module mounting screw (tightening torque range: 0.78 to 1.08N•m)
Mountable with a DIN rail in 6 orientations
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
y RAV1.25-3 (compliant with JIS C 2805)
[Applicable wire size: 0.3 to 1.25mm2]
Applicable solderless terminal
y V2-MS3, RAP2-3SL, TGV2-3N
[Applicable wire size: 1.25 to 2.0mm2]
Accessory User’s manual
5 - 33 5 - 33
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
1 DA TB2 DB
2 DB TB3 DG
3 DG TB4 SLD
Insulation
4 SLD TB5 +24V
5 +24V TB6 (FG)
6 FG
TB7 24G
7 24G
Module TB8 Y0
power supply Load Surge suppressor TB9 COM B
8 Y0 TB10 Y1
9 COM B
TB11 COM B
10 Y1
11 COM B
TB12 Y2
12 Y2 TB13 COM B
13 COM B Triac TB14 Y3
14 Y3 TB15 COM B
15 COM B TB16 Y4
16 Y4 TB17 COM B
17 COM B
TB18 Y5
18 Y5
19 COM B
TB19 COM B
20 Y6 TB20 Y6
Load 21 COM B Surge suppressor TB21 COM B
22 Y7 TB22 Y7
23 COM B TB23 COM B
External load 24 COM A
TB24 COM A
power supply 25 COM B
TB25 COM B
100/200VAC
Triac
All COM B terminals are connected inside the module (shared common).
5 - 34 5 - 34
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMBCOMB COMB
Y8 9 A B C D E F
COMA
OFF→ON 1ms or less
Response time
YF
ON→OFF Total of 1ms and 0.5 cycles or less
Surge suppressor CR absorber (0.01µF + 47Ω)
YE
Wiring method for common 16 points/common (2-wire, terminal block type)
PW L RUN L ERR. Y0 1 2 3 4 5 6 7
YD
Number of occupied stations 32-point assignment/station (16 points used)
YC
Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
YB
Module power supply
Current 85mA or lower (at 24VDC and all points ON)
YA
Noise voltage: 1500Vp-p (AC type), 500Vp-p (DC type), noise width 1µs,
Y9
noise frequency 25 to 60Hz (noise simulator condition)
Noise immunity
Fast transient/burst immunity test
Y8
IEC 61000-4-4:1kV
Y7
2830VACrms for 3 cycles between all AC external terminals and ground (2000m
Y6
Withstand voltage above sea level)
Y5
500VAC for 1 minute between all DC external terminals and ground
Y4
10MΩ or higher between all AC external terminals and ground (500VDC insulation
Y3
resistance tester)
Insulation resistance
10MΩ or higher between all DC external terminals and ground (500VDC insulation
B RATE
40 20 10 8 4 2 1 4 2 1
Y2
resistance tester)
Y1
STATION NO.
Weight 0.35kg
Y0
7-point two-piece terminal block
Communication part, [Transmission circuit, module power supply, FG] (FG)
24G
ON
AJ65SBTB2N-16S
module power supply part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
External
+24V
connection
DG
5 - 35 5 - 35
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
TB2 DB
1 DA
2 DB TB3 DG
3 DG Insulation TB4 SLD
4 SLD TB5 +24V
5 +24V TB6 (FG)
6 FG TB7 24G
7 24G
Module power supply TB8 Y0
Load Surge suppressor TB9 COM B
8 Y0 TB10 Y1
9 COM B TB11 COM B
10 Y1
TB12 Y2
11 COM B
12 Y2
TB13 COM B
13 COM B Triac TB14 Y3
14 Y3 TB15 COM B
15 COM B TB16 Y4
16 Y4 TB17 COM B
17 COM B
TB18 Y5
18 Y5
TB19 COM B
19 COM B
20 Y6 TB20 Y6
21 COM B TB21 COM B
22 Y7 TB22 Y7
23 COM B TB23 COM B
24 Y8 TB24 Y8
25 COM B
TB25 COM B
26 Y9
27 COM B
TB26 Y9
28 YA TB27 COM B
29 COM B TB28 YA
30 YB TB29 COM B
31 COM B TB30 YB
32 YC
TB31 COM B
33 COM B
34 YD
TB32 YC
35 COM B TB33 COM B
36 YE TB34 YD
Load
37 COM B Surge suppressor TB35 COM B
38 YF TB36 YE
39 COM B
TB37 COM B
40 COM A
External load power supply TB38 YF
41 COM B
TB39 COM B
100/200VAC
Triac TB40 COM A
TB41 COM B
All COM B terminals are connected inside the module (shared common).
5 - 36 5 - 36
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
5 - 37 5 - 37
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
Terminal Signal Terminal Signal
number name number name
TB1 DA TB26 Empty
TB2 DG Insulation
TB27 Empty
TB3 DB 1 DA Empty 26 TB28 +24V
2 DG Empty 27
TB4 Empty TB29 CTL+
3 DB +24V 28 24VDC
TB5 SLD 4 Empty CTL+ 29 TB30 (FG)
5 SLD FG 30
TB6 Empty 6 Empty
Constant-voltage circuit
CTLG 31
TB31 CTLG
TB7 24G 7 24G 24G 32 Module TB32 24G
power supply
TB8 Y0 TB33 Y10
TB9 Y1 TB34 Y11
TB10 Y2 Load Load TB35 Y12
8 Y0 Y10 33
TB11 Y3 9 Y1 Y11 34 TB36 Y13
10 Y2 Y12 35
TB12 Y4 11 Y3 Y13 36
TB37 Y14
TB13 Y5 12 Y4 Y14 37 TB38 Y15
13 Y5 Y15 38
TB14 Y6 14 Y6 Y16 39 TB39 Y16
Load Load
TB15 Y7 15 Y7 Y17 40 TB40 Y17
Load 16 COM1 COM3 41 Load
TB16 COM1 17 Y8 Y18 42 TB41 COM3
TB17 Y8 18 Y9 Y19 43 TB42 Y18
19 YA Y1A 44
TB18 Y9 20 YB Y1B 45 TB43 Y19
21 YC Y1C 46
TB19 YA YD Y1D 47
TB44 Y1A
22
TB20 YB Load 23 YE Y1E 48 Load TB45 Y1B
24 YF Y1F 49
TB21 YC 25 COM2 COM4 50
TB46 Y1C
TB22 YD TB47 Y1D
TB23 YE TB48 Y1E
TB24 YF TB49 Y1F
TB25 COM2 TB50 COM4
5 - 38 5 - 38
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
4 1
0 ~0
1
PW L RUN
0 8 10
L ERR.
18
3 2
External power supply for Voltage 24VDC ±10% (ripple ratio: 4Vp-p or lower)
output part DA NC
(CTL+ and CTLG terminals) Current 180mA or lower (at 24VDC and all points ON) DG NC
DB +24V
( FG)
Number of occupied stations 32-point assignment/station (32 points used) NC
24G 24G
CTLG
Current 80mA or lower (at 24VDC and all points ON) Y1 Y11
Y2 Y12
Noise voltage: 1500Vp-p (AC type), 500Vp-p (DC type), noise width 1µs, Y3 Y13
10MΩ or higher between all DC external terminals and ground (500VDC YD Y1D
YE Y1E
insulation resistance tester) YF Y1F
COM4
COM2
Protection degree IP1X AJ65DBTB1
- 32R
Weight 0.7kg
50-point terminal block
[Transmission circuit, module power supply, FG,
External connection system I/O power supply, I/O signal]
M3.5×7 screw (tightening torque range: 0.68 to 0.92N•m)
Applicable solderless terminal: 2 or less
M4 screw with plain washer finished round
Module mounting screw
(tightening torque range: 0.78 to 1.08N•m)
Applicable solderless terminal R1.25-3.5, RAV2-3.5 (compliant with JIS C 2805)
Accessory User’s manual
Part sold separately A6DIN1C, A2CCOM-TB
5 - 39 5 - 39
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
Terminal Signal Terminal Signal
number name number name
TB1 DA TB26 Empty
TB2 DG TB27 Empty
TB3 DB TB28 +24V
TB4 Empty 1 DA
Insulation
Empty 26 TB29 CTL+
TB5 SLD 2 DG Empty 27 24VDC TB30 (FG)
3 DB CTL+ +24V 28
TB6 Empty 4 Empty CTL+ 29 TB31 CTLG
5 SLD FG 30
TB7 24G 6 Empty CTLG CTLG 31
TB32 24G
TB8 Y0 7 24G 24G 32 TB33 Y10
Module power supply
TB9 Y1 TB34 Y11
Load Load
TB10 Y2 8 Y0 CTL+ CTL+ Y10 33 TB35 Y12
9 Y1 Y11 34
TB11 Y3 10 Y2 Y12 35
TB36 Y13
TB12 Y4 11 Y3 Y13 36 TB37 Y14
12 Y4 Y14 37
TB13 Y5 13 Y5 Y15 38 TB38 Y15
TB14 Y6 Load 14 Y6 Y16 39 Load TB39 Y16
15 Y7 Y17 40
TB15 Y7 Load 16 COM1
CTLG CTLG
COM3 41 Load
TB40 Y17
17 Y8 Y18 42
TB16 COM1 CTL+ CTL+ TB41 COM3
18 Y9 Y19 43
TB17 Y8 19 YA Y1A 44 TB42 Y18
20 YB Y1B 45
TB18 Y9 21 YC Y1C 46
TB43 Y19
TB19 YA 22 YD Y1D 47 TB44 Y1A
Load 23 YE Y1E 48 Load
TB20 YB 24 YF Y1F 49 TB45 Y1B
CTLG CTLG
25 COM2 COM4 50
TB21 YC TB46 Y1C
TB22 YD TB47 Y1D
TB23 YE TB48 Y1E
TB24 YF TB49 Y1F
TB25 COM2 TB50 COM4
5 - 40 5 - 40
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
YF
Current 30mA or lower (at 24VDC and all points ON), excluding external load current
YC YD YE
Surge suppressor Zener diode
Wiring method for common 16 points/common (2-wire, spring clamp terminal block type)
Number of occupied stations 32-point assignment/station (16 points used)
YA YB
Module power Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
supply Current 45mA or lower (at 24VDC and all points ON)
Y9
Noise voltage 500Vp-p, noise width 1µs,
Noise immunity
COM+
Y8
noise frequency 25 to 60Hz (DC type noise simulator condition)
NC
Y7
AJ65VBTS2-16T
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
Y6
10MΩ or higher between all DC external terminals and ground (500VDC
Insulation resistance
Y5
insulation resistance tester)
Y4
Protection degree IP1XB
Y2 Y3
Weight 0.24kg
One-touch connector for communication [Transmission circuit] Y1
Communication part
<Optional>
COM+
COM-
NC
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715) B RATE STATION NO.
1 2 4 1 2 4 8 1020 40
5 - 41 5 - 41
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
CONA
1
1
Pin number Signal name
DA
LINK CABLE 2
(IN) 3
2 DB 1 DA
3 DG
4
5
4 Empty 2 DB
5 SLD
CONB
CON A, B 3 DG
1
LINK CABLE 2
1 DA
4 Empty
2 DB
(OUT) 3
4
3 DG 5 SLD
4 Empty
5
5 SLD 1 (FG)
One-touch connector for communication
CONC
2 +24V (UNIT)
1 Insulation
UNIT POWER CABLE(IN)
2
1 FG CON C, D 3 24G (UNIT)
2 +24V(UNIT)
3
4
3 24G(UNIT) 4 Empty
4 Empty
5
5 Empty 5 Empty
COND
UNIT POWER CABLE(OUT) 1
1 FG
Terminal block
2
3
2 +24V(UNIT)
Column A Column B Column C
3 24G(UNIT)
4
5
4 Empty 1 Empty 1 COM+ 1 COM-
5 Empty
One-touch connector for power supply and FG 1
2 Y0 2 COM+ 2 Empty
Constant-voltage circuit
TB1A Empty 3 Y1 3 COM+ 3 Empty
External power supply for output part TB1B COM+
Load
TB1C COM- 4 Y2 4 COM+ 4 Empty
TB2A Y0
TB2B COM+ 5 Y3 5 COM+ 5 Empty
TB2C Empty
TB3A Y1
6 Y4 6 COM+ 6 Empty
TB3B COM+
7 Y5 7 COM+ 7 Empty
TB3C Empty
TB4A Y2 8 Y6 8 COM+ 8 Empty
TB4B COM+
TB4C Empty 9 Y7 9 COM+ 9 Empty
TB5A Y3
TB5B COM+ 10 Y8 10 COM+ 10 Empty
TB5C Empty
TB6A Y4 11 Y9 11 COM+ 11 Empty
TB6B COM+
TB6C Empty
12 YA 12 COM+ 12 Empty
TB7A Y5
13 YB 13 COM+ 13 Empty
TB7B COM+
TB7C Empty 14 YC 14 COM+ 14 Empty
TB8A Y6
TB8B COM+ 15 YD 15 COM+ 15 Empty
TB8C Empty
TB9A Y7 16 YE 16 COM+ 16 Empty
TB9B COM+
TB9C Empty 17 YF 17 COM+ 17 Empty
TB10A Y8
TB10B COM+
TB10C Empty
TB11A Y9
TB11B COM+
TB11C Empty
TB12A YA
TB12B COM+
TB12C Empty
TB13A YB
TB13B COM+
TB13C Empty
TB14A YC
TB14B COM+
TB14C Empty
TB15A YD
TB15B COM+
TB15C Empty
TB16A YE
TB16B COM+
Load TB16C Empty
TB17A YF
TB17B COM+
TB17C Empty
1: Attach an unwired connector plug to an unused one-touch connector for power supply and FG.
5 - 42 5 - 42
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
1: Attach an unwired connector plug to an unused one-touch connector for power supply and FG.
Pin layout
5 - 43 5 - 43
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
NC Y10 Y11 Y12 Y13 Y14 Y15 Y16 Y17 Y18 Y19 Y1A Y1B Y1C Y1D Y1E Y1F
Protection function None
OFF→ON 1ms or less
Response time
ON→OFF 1ms or less (resistive load)
External power Voltage 10.2 to 26.4VDC (ripple ratio: within 5%)
supply for output part Current 30mA or lower (at 24VDC and all points ON), excluding external load current
COM2+
Surge suppressor Zener diode
NC
Wiring method for common 16 points/common (2-wire, spring clamp terminal block type)
Number of occupied stations 32-point assignment/station (32 points used)
Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
Module power supply
Current 60mA or lower (at 24VDC and all points ON)
Noise voltage 500Vp-p, noise width 1µs,
Noise immunity
noise frequency 25 to 60Hz (DC type noise simulator condition)
AJ65VBTS2-32T
COM2+
COM2-
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
YA YB YC YD YE YF
10MΩ or higher between all DC external terminals and ground (500VDC insulation
Insulation resistance
resistance tester)
Protection degree IP1XB
Weight 0.40kg
One-touch connector for communication [Transmission circuit]
Y9
Communication 5-pin IDC plug is sold separately: A6CON-L5P
COM1+
Y8
NC
part <Optional>
Y7
External Online connector for communication: A6CON-LJ5P
Y6
Y5
connection One-touch connector for power supply and FG [Module power supply, FG] Y4
I/O part 2-piece spring clamp terminal block [I/O power supply, I/O signals]
COM1+
COM1-
NC
2
0.66 to 0.98mm (AWG18)
C
PW L RUN
5 - 44 5 - 44
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
1
5 Empty
3 Y1 3 COM1+ 3 Empty
One-touch connector for power supply and FG
TB1A Empty 4 Y2 4 COM1+ 4 Empty
External power supply TB1B COM1+
for output part Load
TB1C COM1- Constant-voltage circuit 5 Y3 5 COM1+ 5 Empty
TB2A Y0
TB2B COM1+ 6 Y4 6 COM1+ 6 Empty
TB2C Empty
TB3A Y1 7 Y5 7 COM1+ 7 Empty
TB3B COM1+
TB3C Empty 8 Y6 8 COM1+ 8 Empty
TB4A Y2
TB4B COM1+
9 Y7 9 COM1+ 9 Empty
Empty
TB4C
10 Y8 10 COM1+ 10 Empty
11 Y9 11 COM1+ 11 Empty
12 YA 12 COM1+ 12 Empty
13 YB 13 COM1+ 13 Empty
TB15A YD
14 YC 14 COM1+ 14 Empty
TB15B COM1+
TB15C Empty
15 YD 15 COM1+ 15 Empty
TB16A YE 16 YE 16 COM1+ 16 Empty
TB16B COM1+
Load
TB16C Empty 17 YF 17 COM1+ 17 Empty
TB17A YF
TB17B COM1+ 18 Empty 18 COM2+ 18 COM2-
TB17C Empty
TB18A Empty 19 Y10 19 COM2+ 19 Empty
External power supply TB18B COM2+
for output part Load
TB18C COM2- Constant-voltage circuit
20 Y11 20 COM2+ 20 Empty
TB19A Y10
TB19B COM2+
21 Y12 21 COM2+ 21 Empty
TB19C Empty
TB20A Y11
22 Y13 22 COM2+ 22 Empty
TB20B COM2+
TB20C Empty
23 Y14 23 COM2+ 23 Empty
TB21A Y12
24 Y15 24 COM2+ 24 Empty
TB21B COM2+
TB21C Empty 25 Y16 25 COM2+ 25 Empty
26 Y17 26 COM2+ 26 Empty
27 Y18 27 COM2+ 27 Empty
28 Y19 28 COM2+ 28 Empty
TB32A Y1D 29 Y1A 29 COM2+ 29 Empty
TB32B COM2+
TB32C Empty 30 Y1B 30 COM2+ 30 Empty
TB33A Y1E
TB33B COM2+
31 Y1C 31 COM2+ 31 Empty
Load
TB33C Empty
TB34A Y1F
32 Y1D 32 COM2+ 32 Empty
TB34B COM2+
33 Y1E 33 COM2+ 33 Empty
TB34C Empty
34 Y1F 34 COM2+ 34 Empty
1: Attach an unwired connector plug to an unused one-
touch connector for power supply and FG.
5 - 45 5 - 45
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
1: Attach an unwired connector plug to an unused one-touch connector for power supply and FG.
Pin layout
5 - 46 5 - 46
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground A J65VBTCE2-8T
PW
10MΩ or higher between all DC external terminals and ground (500VDC insulation Y0
L RUN
Insulation resistance
resistance tester) L ERR.
Y1
Protection degree IP1XB 0
1
Weight 0.10kg Y2
2
One-touch connector for communication [Transmission circuit] 3
Y3 4
Communication 5-pin IDC plug is sold separately: A6CON-L5P 5
6
part <Optional> Y4 7
Online connector for communication: A6CON-LJ5P
Y5
External One-touch connector for power supply and FG
connection [Module power supply, I/O power supply, FG] Y6
Power supply
system 5-pin IDC plug is sold separately: A6CON-PW5P, A6CON-PW5P-SOD
part Y7
<Optional>
Online connector for power supply: A6CON-PWJ5P
Sensor connector (e-CON) [I/O signals]
I/O part
4-pin IDC plug is sold separately. 1
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
Connector for Applicable cable:
communication FANC-110SBH, FA-CBL200PSBH, CS-110
2
0.66 to 0.98mm (AWG18)
Connector for
[φ2.2 to 3.0mm (A6CON-PW5P), φ2.0 to 2.3mm (A6CON-PW5P-SOD)]
Applicable power supply and
Wire diameter: 0.16mm or more
wire size FG
Insulating coating material: PVC (heat-resistant)
Sensor connector (e-CON).
Connector for I/O Applicable connector plugs are sold separately. 1
(applicable wire size: 0.08 to 0.5mm2, depending on the connector plug)
Accessory User’s manual, Holding fixtures for screw installation
5 - 47 5 - 47
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
5 - 48 5 - 48
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
1: Attach an unwired connector plug to an unused one-touch connector for power supply and FG.
5 - 49 5 - 49
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
F
7
Wiring method for common 16 points/common (2-wire, sensor connector (e-CON) type)
AJ65VBTCE2-16T
E
6
Number of occupied stations 32-point assignment/station (16 points used)
D
5
Module power Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
supply Current 45mA or lower (at 24VDC and all points ON)
C
4
Noise voltage 500Vp-p, noise width 1µs,
B
3
Noise immunity
noise frequency 25 to 60Hz (DC type noise simulator condition)
A
2
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
9
10MΩ or higher between all DC external terminals and ground (500VDC insulation
Insulation resistance
resistance tester)
8
Y
Y
Protection degree IP1XB
Weight 0.10kg
D
8 9 A B C D E F
0 1 2 3 4 5 6 7
One-touch connector for communication [Transmission circuit]
PW L RUNL ERR.
C
part <Optional>
Online connector for communication: A6CON-LJ5P
B
ON
CON A
Power supply
system 5-pin IDC plug is sold separately: A6CON-PW5P, A6CON-PW5P-SOD
part
<Optional>
Online connector for power supply: A6CON-PWJ5P
Sensor connector (e-CON) [I/O signals]
I/O part
4-pin IDC plug is sold separately. 1
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
Connector for Applicable cable:
communication FANC-110SBH, FA-CBL200PSBH, CS-110
0.66 to 0.98mm2 (AWG18)
Connector for
[φ2.2 to 3.0mm (A6CON-PW5P), φ2.0 to 2.3mm (A6CON-PW5P-SOD)]
Applicable power supply and
Wire diameter: 0.16mm or more
wire size FG
Insulating coating material: PVC (heat-resistant)
Sensor connector (e-CON).
Connector for
Applicable connector plugs are sold separately. 1
I/O
(applicable wire size: 0.08 to 0.5mm2, depending on the connector plug)
Accessory User’s manual, Holding fixtures for screw installation
5 - 50 5 - 50
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
5 - 51 5 - 51
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
1: Attach an unwired connector plug to an unused one-touch connector for power supply and FG.
Pin layout
5 - 52 5 - 52
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
5 - 53 5 - 53
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
5 - 54 5 - 54
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
Pin layout
5 - 55 5 - 55
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
5 - 56 5 - 56
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
Pin
Pin layout Signal name
number
1 DA
2 DB
CON
3 DG
A, B
4 Empty
CONA
5 SLD
1
1 DA 1 Y0
LINK CABLE 2
2 DB
(IN) 3 2 Empty
4
3 DG CON1
4 Empty 3 +24V
5
5 SLD
4 Empty
CONB 5 4 3 2 1
1
1 DA 1 Y1
LINK CABLE 2
(OUT)
2 DB CONA 2 Empty
3
3 DG CON2
4
4 Empty CONB 3 +24V
5
5 SLD 4 Empty
One-touch connector for communication 43 2 1 1 Y2
CONC
1 Insulation
UNIT POWER CABLE(IN) 1 FG CON1 2 Empty
2
2 +24V(UNIT)
CON3
3 3 +24V
3 24G(UNIT)
4 CON2
4 +24V(I/O) 4 Empty
5
5 24G(I/O)
CON3 1 Y3
I/O POWER CABLE(IN) COND
UNIT POWER CABLE(OUT)
1
1 FG
2 Empty
2 CON4 CON4
3
2 +24V(UNIT) 3 +24V
3 24G(UNIT)
4
4 +24V(I/O) CON5 4 Empty
5
5 24G(I/O) 1 Y4
I/O POWER CABLE(OUT) Constant-voltage circuit
1 CON6 2 Empty
One-touch connector for power supply and FG CON5
CON1
Load 3 +24V
1 CON7
2 4 Empty
3
CON8 1 Y5
4
2 Empty
5 4 3 2 1 CON6
3 +24V
CONC 4 Empty
1 Y6
CON8 COND
2 Empty
Load 1 CON7
2 3 +24V
3
Viewed from the
front of the module 4 Empty
4
1 Y7
2 Empty
CON8
3 +24V
4 Empty
1 (FG)
2 +24V (UNIT)
CON
3 24G (UNIT)
C, D
4 +24V (I/O)
1: Attach an unwired connector plug to an unused one-touch connector for power supply and FG. 5 24G (I/O)
5 - 57 5 - 57
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
1: Attach an unwired connector plug to an unused one-touch connector for power supply and FG.
5 - 58 5 - 58
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
L RUN
Noise voltage 500Vp-p, noise width 1µs,
Noise immunity L ERR
noise frequency 25 to 60Hz (DC type noise simulator condition)
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground 0
1
10MΩ or higher between all DC external terminals and ground (500VDC insulation 2
Insulation resistance 3
4
resistance tester) 5
6
Protection degree IP1XB 7
Weight 0.19kg
8
One-touch connector for communication 9
A
[Transmission circuit] B
C
Communication D
5-pin IDC plug is sold separately. E
part Y0 Y7 Y8 YF F
<Optional>
Online connector for communication: A6CON-LJ5P CON
External C
One-touch connector for power supply and FG
connection
[Module power supply, I/O power supply, FG] CON
system D
Power supply part 5-pin IDC plug is sold separately: A6CON-PW5P, A6CON-PW5P-SOD
<Optional>
Online connector for power supply: A6CON-PWJ5P
One-touch connector for I/O
I/O part
4-pin IDC plug is sold separately.
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
Connector for Applicable cable:
communication FANC-110SBH, FA-CBL200PSBH, CS-110
0.66 to 0.98mm2 (AWG18)
Connector for
[φ2.2 to 3.0mm (A6CON-PW5P), φ2.0 to 2.3mm (A6CON-PW5P-SOD)]
power supply and
Applicable Wire diameter: 0.16mm or more
FG
wire size Insulating coating material: PVC (heat-resistant)
φ1.0 to 1.4 (A6CON-P214), φ1.4 to 2.0 (A6CON-P220)
[Applicable wire size: 0.14 to 0.2mm2]
Connector for I/O
φ1.0 to 1.4 (A6CON-P514), φ1.4 to 2.0 (A6CON-P520)
[Applicable wire size: 0.3 to 0.5mm2]
Accessory User’s manual
5 - 59 5 - 59
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
Pin
Pin layout Signal name
number
1 DA
2 DB
CON
3 DG
A, B
4 Empty
5 SLD
1 Y0
CON 2 Empty
1 3 +24V
4 Empty
1 Y1
CON 2 Empty
2 3 +24V
4 Empty
1 Y2
CON 2 Empty
3 3 +24V
1
CONA 4 Empty
1 DA 1 Y3
LINK CABLE 2
2 DB
(IN) 3
3 DG
CON 2 Empty
4
4 Empty 4 3 +24V
5
5 SLD 4 Empty
CONB 1 Y4
1
1 DA CON 2 Empty
LINK CABLE 2
(OUT) 3
2 DB 5 3 +24V
3 DG
4 4 Empty
4 Empty
5
5 SLD 1 Y5
5 4 3 2 1
One-touch connector for communication
CON 2 Empty
CONC
CONA 6 3 +24V
1 Insulation
UNIT POWER CABLE(IN) 1 FG CONB 4 Empty
2
3
2 +24V(UNIT)
4321 4321
1 Y6
3 24G(UNIT)
4 CON 2 Empty
4 +24V(I/O) CON1 CON9
5 7 3 +24V
5 24G(I/O)
I/O POWER CABLE(IN) CON2 CON10 4 Empty
COND
UNIT POWER CABLE(OUT)
1
1 FG CON3 CON11 1 Y7
2 CON 2 Empty
2 +24V(UNIT)
3 CON4 CON12
3 24G(UNIT) 8 3 +24V
4
4 +24V(I/O) CON5 CON13 4 Empty
5
5 24G(I/O)
I/O POWER CABLE(OUT) Constant-voltage circuit CON6 CON14
1 Y8
One-touch connector for power supply and FG
1 CON 2 Empty
CON7 CON15 9
CON1 3 +24V
Load 1
CON8 CON16 4 Empty
2
3
1 Y9
5 4 3 2 1
4 CON 2 Empty
CONC 10 3 +24V
COND 4 Empty
1 YA
Viewed from the CON 2 Empty
front of the module 11 3 +24V
CON16
Load 4 Empty
1
2
1 YB
3 CON 2 Empty
4 12 3 +24V
4 Empty
1 YC
CON 2 Empty
13 3 +24V
4 Empty
1 YD
CON 2 Empty
14 3 +24V
4 Empty
1 YE
CON 2 Empty
15 3 +24V
4 Empty
1 YF
CON 2 Empty
16 3 +24V
4 Empty
1 (FG)
1: Attach an unwired connector plug to an unused one-touch connector for power supply and 2 +24V (UNIT)
CON
3 24G (UNIT)
FG. C, D
4 +24V (I/O)
5 24G (I/O)
5 - 60 5 - 60
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
1: Attach an unwired connector plug to an unused one-touch connector for power supply and FG.
5 - 61 5 - 61
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
ON
Surge suppressor Zener diode
COM-
CTL+
Wiring method for common 32 points/common (1-wire, one-touch connector type)
B RATE
40 20 10 8 4 2 1 4 2 1
Number of occupied stations 32-point assignment/station (32 points used)
Y1C
Y1D
Y1E
Y1F
STATION NO.
Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
Module power supply
Y1A
Y1B
Y18
Y19
Current 60mA or lower (at 24VDC and all points ON)
Noise voltage 500Vp-p, noise width 1µs,
Y14
Y15
Y16
Y17
Noise immunity
noise frequency 25 to 60Hz (DC type noise simulator condition)
Y10-Y1F
Y0-YF
Y10
Y11
Y12
Y13
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
10MΩ or higher between all DC external terminals and ground (500VDC
YC
YD
YE
YF
Y1011121314 1516 17 Y18 19 1A1B1C1D1E1F
Y8 9 A B C D E F
Insulation resistance
insulation resistance tester)
YA
YB
Y8
Y9
A J65SBTC1-32T
Protection degree IP2X
Y4
Y5
Y6
Y7
Weight 0.16kg
7-point two-piece terminal block
Y0
Y1
Y2
Y3
Y0 1 2 3 4 5 6 7
(FG)
Applicable solderless terminal: 2 or less 24G
External
DA DG +24V
connection
[I/O power supply]
system I/O power supply part
DB
5 - 62 5 - 62
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
Terminal
Signal name
number
TB1 DA
TB2 DB
TB3 DG
1 DA TB4 SLD
2 DB TB5 +24V
3 DG Insulation TB6 (FG)
4 SLD
5 +24V
TB7 24G
6 FG Pin number Signal name
7 24G 1 Y0
Module power supply
CON1 2 Y1
Load
1 CON1
3 Y2
2
3 4 Y3
Load
4 1 Y4
2 Y5
CON2
3 Y6
4 Y7
1 Y8
2 Y9
CON3
3 YA
4 YB
1 YC
CON8
Load 2 YD
1 CON4
2 3 YE
3 4 YF
Load 4
1 Y10
2 Y11
CON5
3 Y12
4 Y13
1 Y14
2 Y15
CON6
External power supply 3 Y16
for output part 4 Y17
8 CTL+ 1 Y18
9 COM-
2 Y19
CON7
Constant-voltage circuit 3 Y1A
Load
Load power supply External power supply for output
4 Y1B
part and load power supply 1 Y1C
8 CTL+
(common) 2 Y1D
9 COM- CON8
3 Y1E
4 Y1F
Terminal
Signal name
number
TB8 CLT+
TB9 COM-
Pin layout
5 - 63 5 - 63
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
ON
Wiring method for common 32 points/common (1-wire, one-touch connector type)
COM-
CTL+
B RATE
Number of occupied stations 32-point assignment/station (32 points used)
40 20 10 8 4 2 1 4 2 1
Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
Y1C
Y1D
Y1E
Y1F
Module power supply
STATION NO.
Current 60mA or lower (at 24VDC and all points ON)
Y1A
Y1B
Y18
Y19
Noise voltage 500Vp-p, noise width 1µs,
Noise immunity
noise frequency 25 to 60Hz (DC type noise simulator condition)
Y14
Y15
Y16
Y17
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
Y10-Y1F
Y0-YF
Y10
Y11
Y12
Y13
10MΩ or higher between all DC external terminals and ground (500VDC
Insulation resistance
insulation resistance tester)
YC
YD
YE
YF
Y1011121314 1516 17 Y18 19 1A1B1C1D1E1F
Y8 9 A B C D E F
Protection degree IP2X
YA
YB
Y8
Y9
A J65SBTC1-32T1
Weight 0.16kg
Y4
Y5
Y6
Y7
7-point two-piece terminal block
Communication part, [Transmission circuit, module power supply, FG]
Y0
Y1
Y2
Y3
Y0 1 2 3 4 5 6 7
module power supply part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
Applicable solderless terminal: 2 or less
(FG)
24G
External
2-point direct-mount terminal block
connection
DA DG +24V
5 - 64 5 - 64
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
Terminal
Signal name
number
TB1 DA
TB2 DB
TB3 DG
1 DA TB4 SLD
2 DB
TB5 +24V
3 DG Insulation
4 SLD TB6 (FG)
5 +24V TB7 24G
6 FG Pin number Signal name
7 24G
Module power supply 1 Y0
CON1
Load 2 Y1
1 CON1
2 3 Y2
3 4 Y3
Load 4
1 Y4
2 Y5
CON2
3 Y6
4 Y7
1 Y8
2 Y9
CON3
3 YA
4 YB
CON8
1 YC
Load 1 2 YD
CON4
2 3 YE
3 4 YF
Load 4
1 Y10
2 Y11
CON5
3 Y12
4 Y13
1 Y14
2 Y15
External power CON6
3 Y16
supply for output part
4 Y17
8 CTL+ 1 Y18
9 COM-
2 Y19
CON7
Load power supply 3 Y1A
Constant-voltage circuit
Load 4 Y1B
External power supply for output part 1 Y1C
and load power supply (common) 2 Y1D
8 CTL+
CON8
9 COM- 3 Y1E
4 Y1F
Terminal
Signal name
number
TB8 CLT+
TB9 COM-
Pin layout
5 - 65 5 - 65
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
ON
output part Current 50mA or lower (TYP. 24VDC/common), excluding external load current
Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 YA YB YC YD YE YF NC NC CTL+ CTL+
B RATE
Y10 Y11 Y12 Y13 Y14 Y15 Y16 Y17 Y18 Y19 Y1A Y1B Y1C Y1D Y1E Y1F NC NC COM- COM-
40 20 10 8 4 2 1 4 2 1
Surge suppressor Zener diode
Wiring method for common 32 points/common (1-wire, FCN connector type)
STATION NO.
Number of occupied stations 32-point assignment/station (32 points used)
Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
Module power supply
Current 60mA or lower (at 24VDC and all points ON)
Y10-Y1F
Noise voltage 500Vp-p, noise width 1µs,
Y0-YF
Noise immunity
noise frequency 25 to 60Hz (DC type noise simulator condition)
A J65SBTCF1-32T
Insulation resistance
insulation resistance tester)
Weight 0.15kg
7-point two-piece terminal block
Y0 1 2 3 4 5 6 7
(FG)
24G
module power supply part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
connection
Applicable solderless terminal: 2 or less +24V
system
I/O power supply part, 40-pin connector [I/O power supply, I/O signal]
SLD
DG
5 - 66 5 - 66
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
Pin layout Terminal number Signal name
TB1 DA
TB2 DB
1 DA
2 DB TB3 DG
3 DG Insulation TB4 SLD
4 SLD TB5 +24V
5 +24V
TB6 (FG)
6 FG
7 24G TB7 24G
Module power supply Pin Signal Pin Signal
Load number name number name
B20 Y0
B19 Y1 B20 Y0 A20 Y10
B18 Y2 B19 Y1 A19 Y11
B17 Y3 B18 Y2 A18 Y12
B16 Y4
B17 Y3 A17 Y13
B15 Y5
B14 Y6 B16 Y4 A16 Y14
B13 Y7 B15 Y5 A15 Y15
B12 Y8 B14 Y6 A14 Y16
B11 Y9
B13 Y7 A13 Y17
B10 YA
B9 YB B12 Y8 A12 Y18
B8 YC B11 Y9 A11 Y19
B7 YD B10 YA A10 Y1A
B6 YE
B9 YB A9 Y1B
B5 YF
A20 Y10 B8 Y0 A8 Y1C
Viewed from the
A19 Y11 B7 YD A7 Y1D
front of the module
A18 Y12 B6 YE A6 Y1E
A17 Y13
B5 YF A5 Y1F
A16 Y14
A15 Y15
B4 Empty A4 Empty
A14 Y16 B3 Empty A3 Empty
A13 Y17 B2 CTL+ A2 COM-
A12 Y18
B1 CTL+ A1 COM-
A11 Y19
A10 Y1A
A9 Y1B
A8 Y1C
A7 Y1D
Load A6 Y1E
A5 Y1F
B1,2 CTL+
External power supply
A1,2 COM
for output part
Load
External power supply for output part
and load power supply (common)
B1,2 CTL+
A1,2 COM
5 - 67 5 - 67
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
Response time YE
YF
10MΩ or higher between all DC external terminals and ground (500VDC insulation
Insulation resistance
resistance tester)
Y Y
Protection degree IP67 Y Y
Weight 0.40kg
Accessory User’s manual
Optional item Waterproof cap: A6CAP-WP2 (20 pieces)
Other connecting devices Refer to Section 1.6.1.
5 - 68 5 - 68
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
Pin layout Connector for communication
Pin
LINK IN LINK OUT
number
1 SLD SLD
LINK IN 2 DB DB
4
2 3 DG DG
3
4 DA DA
1 Communication
circuit 5 No pins Empty
110
Connector for power supply
LINK OUT 130 Pin
4 UNIT POWER AUX.
2 LINK IN number
3 Terminating resistor Male 1 +24V(UNIT) +24V(I/O)
1 setting switch 2 1
5 3 4
2 Empty Empty
3 24G(UNIT) 24G(I/O)
4 Empty Empty
LINK OUT
Insulation 5 FG FG
UNIT POWER Female
1 Connector for I/O
1 2
3 5
4 3 Pin Signal Pin Signal
5
number name number name
2
4 UNIT POWER/AUX. 1 +24V 1 +24V
Module mounting screw (FG)
2 Y1 2 Y9
Male Y0 Y8
2 1 Y1 3 Empty Y9 3 Empty
5
3 4
AUX. 4 Y0 4 Y8
1
3 5 Empty 5 Empty
5 I/O connector
Constant-voltage 1 +24V 1 +24V
2
4 circuit Female 2 Y3 2 YB
1 2 Y2 YA
4 5
3 Y3 3 Empty YB 3 Empty
Connector for I/O 4 Y2 4 YA
Load
5 Empty 5 Empty
4
Load 2 Front view 1 +24V 1 +24V
1 2 Y5 2 YD
3 Y4 YC
Y5 3 Empty YD 3 Empty
5
4 Y4 4 YC
5 Empty 5 Empty
1 +24V 1 +24V
2 Y7 2 YF
Y6 YE
Y7 3 Empty YF 3 Empty
4 Y6 4 YE
5 Empty 5 Empty
Load 4
Load 2
1
3
5
5 - 69 5 - 69
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
Protection function Y8
Y9
Response time
ON→OFF 1.5ms or less (resistive load)
External power supply for Voltage 10.2 to 28.8VDC (ripple ratio: within 5%)
output part Current 30mA or lower (at 24VDC and all points ON), excluding external load current
Surge suppressor Zener diode
Y Y
5 - 70 5 - 70
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
External connection
Pin layout Connector for communication
Pin
LINK IN LINK OUT
number
LINK IN 1 SLD SLD
4
2 2 DB DB
3 3 DG DG
1 Communication
circuit 4 DA DA
110 5 No pins Empty
LINK OUT 130 Connector for power supply
4
2
Pin
UNIT POWER AUX.
3 Terminating resistor
number
LINK IN
1 setting switch 1 +24V(UNIT) +24V(I/O)
5 Male
2 1 2 Empty Empty
3 4
3 24G(UNIT) 24G(I/O)
4 Empty Empty
Insulation LINK OUT
UNIT POWER 5 FG FG
1
Female Connector for I/O
3
1 2
5 4 5
3 Pin Signal Pin Signal
2
number name number name
4
Module mounting screw (FG) UNIT POWER/AUX. 1 Empty 1 Empty
Male 2 Y1 2 Y9
Y0 Y8
AUX. 2 5
1
Y1 3 24G Y9 3 24G
1 3 4
3 4 Y0 4 Y8
5 Constant-voltage 5 Empty 5 Empty
2 circuit I/O connector
1 Empty 1 Empty
4 Female
1 2 2 Y3 2 YB
4 5
3 Y2 YA
Y3 3 24G YB 3 24G
4 Y2 4 YA
Connector for I/O 5 Empty 5 Empty
Front view
Load 4 1 Empty 1 Empty
Load 2 2 Y5 2 YD
1 Y4 YC
3 Y5 3 24G YD 3 24G
5 4 Y4 4 YC
5 Empty 5 Empty
1 Empty 1 Empty
2 Y7 2 YF
Y6 YE
Y7 3 24G YF 3 24G
4 Y6 4 YE
5 Empty 5 Empty
Load 4
Load 2
1
3
5
5 - 71 5 - 71
5 SPECIFICATIONS FOR OUTPUT MODULES
MELSEC-A
MEMO
5 - 72 5 - 72
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
This chapter describes the specifications for a combined module that can be
connected to the CC-Link system.
DC24V
B RATE
40 20 10 8 4 2 1 4 2 1
Voltage
External power (ripple ratio: within 5%)
YB
supply for 14.6mA or lower STATION NO.
YA
output part Current (at 24VDC and all points ON),
Y9
excluding external load current
ON
Y8
Input type Positive common (sink type) Surge suppressor Zener diode
X3
device
AJ65SBTB32-8DT
X1
Wiring method for common 8 points/common (input: 3-wire terminal block type, output: 2-wire terminal block type)
X0
supply Current 45mA or lower (at 24VDC and all points ON)
+24V
Noise immunity
DG
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
10MΩ or higher between all DC external terminals and ground (500VDC insulation resistance
Insulation resistance
tester)
Protection degree IP2X
Weight 0.18kg
Communication
7-point two-piece terminal block [Transmission circuit, module power supply, FG]
part,
M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
External module power
Applicable solderless terminal: 2 or less
connection supply part
system I/O power supply 18-point direct-mount terminal block [I/O power supply, I/O signal]
part, M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
I/O part Applicable solderless terminal: 2 or less
M4 screw with plain washer finished round (tightening torque range: 0.78 to 1.08N•m)
Module mounting screw
Mountable with a DIN rail in 6 orientations
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
y RAV1.25-3 (compliant with JIS C 2805)
2
[Applicable wire size: 0.3 to 1.25mm ]
Applicable solderless terminal
y V2-MS3, RAP2-3SL, TGV2-3N
2
[Applicable wire size: 1.25 to 2.0mm ]
Accessory User’s manual
6-1 6-1
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
Terminal
Signal name
number
1 DA TB1 DA
2 DB TB2 DB
3 DG Insulation TB3 DG
4 SLD TB4 SLD
5 +24V TB5 +24V
6 FG
TB6 (FG)
7 24G
Module power supply TB7 24G
Black TB8 X0
3-wire sensor 8 X0
Brown TB9 COM+
9 COM+
Blue TB10 X1
10 X1
11 COM- TB11 COM-
12 X2 TB12 X2
13 COM+ TB13 COM+
14 X3 TB14 X3
Load 15 COM-
TB15 COM-
16 Y8
17 COM+ TB16 Y8
18 Y9 TB17 COM+
19 COM+ TB18 Y9
20 YA TB19 COM+
Load 21 COM+
TB20 YA
22 YB
23 COM+
TB21 COM+
24 DC24V TB22 YB
25 DC24G TB23 COM+
External power supply
TB24 DC24V
for output part
TB25 DC24G
Constant-voltage circuit
6-2 6-2
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
DC24V
B RATE
40 20 10 8 4 2 1 4 2 1
power
14.6mA or lower
YB
supply for
STATION NO.
Current (at 24VDC and all points ON),
YA
output part
excluding external load current
Y9
Input type Positive common (sink type) Surge suppressor Zener diode
ON
Y8
Supply current for connected
1.0A or lower/common
X3
device
X2
AJ65SBTB32-8DT2
Wiring method for common 8 points/common (input: 3-wire terminal block type, output: 2-wire terminal block type)
X1
Number of occupied stations 32-point assignment/station (8 points used)
X0
Module power Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
X0 1 2 3 Y8 9 A B
supply Current 45mA or lower (at 24VDC and all points ON)
(FG)
24G
Noise voltage 500Vp-p, noise width 1µs,
Noise immunity
noise frequency 25 to 60Hz (DC type noise simulator condition) DA DG +24V
DB SLD
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
10MΩ or higher between all DC external terminals and ground (500VDC insulation resistance
Insulation resistance
tester)
Protection degree IP2X
Weight 0.18kg
Communication 7-point two-piece terminal block
part, [Transmission circuit, module power supply, FG]
module power M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
External
supply part Applicable solderless terminal: 2 or less
connection
18-point direct-mount terminal block
system I/O power supply
[I/O power supply, I/O signal]
part,
M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
I/O part
Applicable solderless terminal: 2 or less
M4 screw with plain washer finished round (tightening torque range: 0.78 to 1.08N•m)
Module mounting screw
Mountable with a DIN rail in 6 orientations
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
y RAV1.25-3 (compliant with JIS C 2805)
[Applicable wire size: 0.3 to 1.25mm2]
Applicable solderless terminal
y V2-MS3, RAP2-3SL, TGV2-3N
[Applicable wire size: 1.25 to 2.0mm2]
Accessory User’s manual
6-3 6-3
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
1 DA TB2 DB
2 DB TB3 DG
3 DG TB4 SLD
Insulation
4 SLD TB5 +24V
5 +24V TB6 (FG)
6 FG TB7 24G
7 24G
Module power supply TB8 X0
TB9 COM+
Black
3-wire sensor 8 X0 TB10 X1
Brown 9 COM+ TB11 COM-
Blue 10 X1
TB12 X2
11 COM-
TB13 COM+
12 X2
13 COM+ TB14 X3
14 X3 TB15 COM-
15 COM- TB16 Y8
Load
16 Y8 TB17 COM+
17 COM+ TB18 Y9
18 Y9 TB19 COM+
19 COM+
TB20 YA
20 YA
21 COM+
TB21 COM+
Load TB22 YB
22 YB
23 COM+ TB23 COM+
24 DC24V TB24 DC24V
25 DC24G TB25 DC24G
External power supply
for output part
Constant-voltage circuit
6-4 6-4
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
YF COM-
YE COM+
B RATE
40 20 10 8 4 2 1 4 2 1
19.2 to 26.4VDC
External Voltage
(ripple ratio: within 5%)
YD
STATION NO.
power supply
YC
17.8mA or lower
YB
for output
Current (at 24VDC and all points ON),
YA
part
Y9
excluding external load current
ON
Y8
X7
Input type Positive common (sink type) Surge suppressor Zener diode
X6
Y8 9 A B C D E F
X5
Wiring method for common 16 points/common (1-wire, terminal block type )
X4
AJ65SBTB1-16DT
X3
Number of occupied stations 32-point assignment/station (16 points used)
X2
X1
Module power Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
X0
X0 1 2 3 4 5 6 7
supply Current 50mA or lower (at 24VDC and all points ON)
Noise voltage 500Vp-p, noise width 1µs,
(FG)
24G
Noise immunity
noise frequency 25 to 60Hz (DC type noise simulator condition)
+24V
SLD
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
DA DG
10MΩ or higher between all DC external terminals and ground (500VDC insulation resistance DB
Insulation resistance
tester)
Protection degree IP2X
Weight 0.18kg
7-point two-piece terminal block
Communication part,
[Transmission circuit, module power supply, FG]
module power supply
M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
External part
Applicable solderless terminal: 2 or less
connection
18-point direct-mount terminal block
system I/O power supply
[I/O power supply, I/O signal]
part,
M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
I/O part
Applicable solderless terminal: 2 or less
M4 screw with plain washer finished round (tightening torque range: 0.78 to 1.08N•m)
Module mounting screw
Mountable with a DIN rail in 6 orientations
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
y RAV1.25-3 (compliant with JIS C 2805)
[Applicable wire size: 0.3 to 1.25mm2]
Applicable solderless terminal
y V2-MS3, RAP2-3SL, TGV2-3N
[Applicable wire size: 1.25 to 2.0mm2]
Accessory User’s manual
6-5 6-5
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
TB2 DB
1 DA
TB3 DG
2 DB
3 DG TB4 SLD
Insulation
4 SLD TB5 +24V
5 +24V TB6 (FG)
6 FG TB7 24G
7 24G TB8 X0
Module power supply
TB9 X1
8 X0 TB10 X2
9 X1 TB11 X3
10 X2 TB12 X4
11 X3
TB13 X5
12 X4
13 X5
TB14 X6
14 X6 TB15 X7
15 X7 TB16 Y8
Load
16 Y8 TB17 Y9
17 Y9 TB18 YA
18 YA
TB19 YB
19 YB
TB20 YC
20 YC
21 YD TB21 YD
22 YE TB22 YE
Load
23 YF TB23 YF
TB24 COM+
TB25 COM-
24 COM+
External power supply
25 COM-
for output part Constant-voltage circuit
Load power supply
Load
External power supply for output part
24 COM+
and load power supply (common)
25 COM-
6-6 6-6
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
YF COM-
YE COM+
19.2 to 26.4VDC
B RATE
40 20 10 8 4 2 1 4 2 1
External Voltage
(ripple ratio: within 5%)
power
YD
STATION NO.
17.8mA or lower
YC
supply for
YB
Current (at 24VDC and all points ON),
output part
YA
Y9
excluding external load current
ON
Y8
Input type Positive common (sink type) Surge suppressor Zener diode
X7
X6
Y8 9 A B C D E F
Wiring method for common 16 points/common (1-wire, terminal block type)
X5
X4
AJ65SBTB1-16DT1
Number of occupied stations 32-point assignment/station (16 points used)
X3
X2
Module power Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
X1
supply
X0
Current 55mA or lower (at 24VDC and all points ON)
X0 1 2 3 4 5 6 7
Noise voltage 500Vp-p, noise width 1µs,
Noise immunity
(FG)
24G
noise frequency 25 to 60Hz (DC type noise simulator condition)
+24V
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
SLD
DA DG
10MΩ or higher between all DC external terminals and ground (500VDC insulation resistance
Insulation resistance
DB
tester)
Protection degree IP2X
Weight 0.18kg
Communication 7-point two-piece terminal block
part, [Transmission circuit, module power supply, FG]
module power M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
External
supply part Applicable solderless terminal: 2 or less
connection
18-point direct-mount terminal block
system I/O power supply
[I/O power supply, I/O signal]
part,
M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
I/O part
Applicable solderless terminal: 2 or less
M4 screw with plain washer finished round (tightening torque range: 0.78 to 1.08N•m)
Module mounting screw
Mountable with a DIN rail in 6 orientations
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
y RAV1.25-3 (compliant with JIS C 2805)
[Applicable wire size: 0.3 to 1.25mm2]
Applicable solderless terminal
y V2-MS3, RAP2-3SL, TGV2-3N
[Applicable wire size: 1.25 to 2.0mm2]
Accessory User’s manual
6-7 6-7
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
1 DA TB2 DB
2 DB TB3 DG
3 DG Insulation TB4 SLD
4 SLD TB5 +24V
5 +24V TB6 (FG)
6 FG TB7 24G
7 24G
Module power supply TB8 X0
TB9 X1
8 X0 TB10 X2
9 X1 TB11 X3
10 X2
TB12 X4
11 X3
TB13 X5
12 X4
13 X5 TB14 X6
14 X6 TB15 X7
Load
15 X7 TB16 Y8
16 Y8 TB17 Y9
17 Y9 TB18 YA
18 YA TB19 YB
19 YB
TB20 YC
20 YC
21 YD
TB21 YD
22 YE TB22 YE
Load
23 YF TB23 YF
TB24 COM+
TB25 COM-
24 COM+
External power supply 25 COM-
for output part Constant-voltage circuit
Load power supply
Load
External power supply for output part
24 COM+
and load power supply (common)
25 COM-
6-8 6-8
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
COM-
COM+
External Voltage 19.2 to 26.4VDC
B RATE
40 20 10 8 4 2 1 4 2 1
YF
power supply (ripple ratio: within 5%)
YE
YD
STATION NO.
for output Current 17.8mA or lower
YC
YB
part (at 24VDC and all points ON),
YA
Y9
excluding external load current
ON
Y8
Input type Positive common (sink type) Surge suppressor Zener diode
X7
X6
Y8 9 A B C D E F
Wiring method for common 16 points/common (1-wire, terminal block type)
X5
X4
AJ65SBTB1-16DT2
Number of occupied stations 32-point assignment/station (16 points used)
X3
X2
Module power Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
X1
supply
X0
Current 50mA or lower (at 24VDC and all points ON)
X0 1 2 3 4 5 6 7
Noise voltage 500Vp-p, noise width 1µs,
Noise immunity
(FG)
24G
noise frequency 25 to 60Hz (DC type noise simulator condition)
+24V
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
SLD
DA DG
10MΩ or higher between all DC external terminals and ground (500VDC insulation resistance
Insulation resistance
tester) DB
6-9 6-9
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
1
TB2 DB
DA
2 DB TB3 DG
3 DG TB4 SLD
Insulation
4 SLD TB5 +24V
5 +24V TB6 (FG)
6 FG TB7 24G
7 24G
Module power supply TB8 X0
TB9 X1
8 X0 TB10 X2
9 X1 TB11 X3
10 X2
TB12 X4
11 X3
TB13 X5
12 X4
13 X5
TB14 X6
14 X6 TB15 X7
15 X7 TB16 Y8
Load
16 Y8 TB17 Y9
17 Y9 TB18 YA
18 YA TB19 YB
19 YB
TB20 YC
20 YC
21 YD
TB21 YD
22 YE TB22 YE
Load
23 YF TB23 YF
TB24 COM+
TB25 COM-
24 COM+
External power supply
25 COM-
for output part Constant-voltage circuit
Load power supply
Load
External power supply for output part
24 COM + and load power supply (common)
25 COM-
6 - 10 6 - 10
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
COM-
19.2 to 26.4VDC
COM+
Voltage
B RATE
40 20 10 8 4 2 1 4 2 1
External power (ripple ratio: within 5%)
YF
YE
supply for 17.8mA or lower
YD
STATION NO.
YC
output part Current (at 24VDC and all points ON),
YB
YA
excluding external load current
Y9
ON
Input type Positive common (sink type) Surge suppressor Zener diode
Y8
X7
Wiring method for common 16 points/common (1-wire, terminal block type)
X6
Y8 9 A B C D E F
X5
Number of occupied stations 32-point assignment/station (16 points used)
X4
AJ65SBTB1-16DT3
X3
Module power Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
X2
X1
supply Current 55mA or lower (at 24VDC and all points ON)
X0
X0 1 2 3 4 5 6 7
Noise voltage 500Vp-p, noise width 1µs,
Noise immunity
noise frequency 25 to 60Hz (DC type noise simulator condition)
(FG)
24G
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
+24V
SLD
10MΩ or higher between all DC external terminals and ground (500VDC insulation resistance
DA DG
Insulation resistance
tester)
DB
Protection degree IP2X
Weight 0.18kg
7-point two-piece terminal block
Communication part,
[Transmission circuit, module power supply, FG]
module power supply
M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
External part
Applicable solderless terminal: 2 or less
connection
18-point direct-mount terminal block
system I/O power supply
[I/O power supply, I/O signal]
part,
M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
I/O part
Applicable solderless terminal: 2 or less
M4 screw with plain washer finished round (tightening torque range: 0.78 to 1.08N•m)
Module mounting screw
Mountable with a DIN rail in 6 orientations
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
y RAV1.25-3 (compliant with JIS C 2805)
[Applicable wire size: 0.3 to 1.25mm2]
Applicable solderless terminal
y V2-MS3, RAP2-3SL, TGV2-3N
[Applicable wire size: 1.25 to 2.0mm2]
Accessory User’s manual
6 - 11 6 - 11
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
TB2 DB
1 DA
TB3 DG
2 DB
3 DG TB4 SLD
Insulation
4 SLD TB5 +24V
5 +24V TB6 (FG)
6 FG TB7 24G
7 24G
Module power supply TB8 X0
TB9 X1
8 X0 TB10 X2
9 X1 TB11 X3
10 X2
TB12 X4
11 X3
12 X4 TB13 X5
13 X5 TB14 X6
14 X6 TB15 X7
Load 15 X7 TB16 Y8
16 Y8
TB17 Y9
17 Y9
TB18 YA
18 YA
19 YB TB19 YB
20 YC TB20 YC
21 YD TB21 YD
Load 22 YE TB22 YE
23 YF
TB23 YF
TB24 COM+
TB25 COM-
24 COM+
External power supply 25 COM-
for output part Constant-voltage circuit
Load power supply
Load
External power supply for output part
24 COM+ and load power supply (common)
25 COM-
6 - 12 6 - 12
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
COM+ COM- COM+ COM- COM+ COM- COM+ COM- COM+ COM+ COM+ COM+ COM+ COM+ COM+ COM+ DC24G
protection, overheat protection
DC24V
B RATE
40 20 10 8 4 2 1 4 2 1
OFF→ON 1.5ms or less (at 24VDC) Response OFF→ON 0.5ms or less
YF
Response time
STATION NO.
ON→OFF 1.5ms or less (at 24VDC) time ON→OFF 1.5ms or less (resistive load)
YE
19.2 to 26.4VDC
YD
Voltage
External (ripple ratio: within 5%)
ON
YC
power supply 17.8mA or lower
YB
for output part Current (at 24VDC and all points ON),
YA
excluding external load current
Y9
Input type Positive common (sink type) Surge suppressor Zener diode
Y8
Supply current for connected
1.0A or lower/common
X7
device
X6
Wiring method for common 16 points/common (input: 3-wire terminal block type, output: 2-wire terminal block type)
X5
Number of occupied stations 32-point assignment/station (16 points used)
X4
Module power Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
X3
supply Current 50mA or lower (at 24VDC and all points ON) Y8 9 A B C D E F
X2
AJ65SBTB32-16DT
Noise voltage 500Vp-p, noise width 1µs,
Noise immunity
X1
noise frequency 25 to 60Hz (DC type noise simulator condition) X0
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
PW L RUN L ERR. X0 1 2 3 4 5 6 7
10MΩ or higher between all DC external terminals and ground (500VDC insulation resistance
Insulation resistance
(FG)
24G
tester)
+24V
Weight 0.25kg
DB
DA
6 - 13 6 - 13
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
TB2 DB
1 DA
2 DB
TB3 DG
3 DG TB4 SLD
Insulation TB5 +24V
4 SLD
5 +24V TB6 (FG)
6 FG TB7 24G
7 24G
Module power supply TB8 X0
TB9 COM+
Black
3-wire sensor 8 X0 TB10 X1
Brown
9 COM+ TB11 COM-
Blue 10 X1
TB12 X2
11 COM-
12 X2 TB13 COM+
13 COM+ TB14 X3
14 X3 TB15 COM-
15 COM- TB16 X4
16 X4 TB17 COM+
17 COM+
TB18 X5
18 X5
19 COM- TB19 COM-
20 X6 TB20 X6
21 COM+ TB21 COM+
22 X7 TB22 X7
23 COM-
Load TB23 COM-
24 Y8
TB24 Y8
25 COM+
26 Y9 TB25 COM+
27 COM+ TB26 Y9
28 YA TB27 COM+
29 COM+ TB28 YA
30 YB
TB29 COM+
31 COM+
32 YC
TB30 YB
33 COM+ TB31 COM+
34 YD TB32 YC
35 COM+ TB33 COM+
36 YE TB34 YD
37 COM+
Load TB35 COM+
38 YF
39 COM+
TB36 YE
40 DC24V TB37 COM+
41 DC24G TB38 YF
External power supply
TB39 COM+
for output part
TB40 DC24V
Constant-voltage circuit
TB41 DC24G
6 - 14 6 - 14
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
COM+ COM- COM+ COM- COM+ COM- COM+ COM- COM+ COM+ COM+ COM+ COM+ COM+ COM+ COM+ DC24G
Protection function None
DC24V
B RATE
40 20 10 8 4 2 1 4 2 1
OFF→ON 1.5ms or less (at 24VDC) Response OFF→ON 0.5ms or less
YF
Response time
STATION NO.
ON→OFF 1.5ms or less (at 24VDC) time ON→OFF 1.5ms or less (resistive load)
YE
19.2 to 26.4VDC
YD
Voltage
External (ripple ratio: within 5%)
ON
YC
power supply 17.8mA or lower
YB
for output part Current (at 24VDC and all points ON),
YA
excluding external load current
Y9
Input type Positive common (sink type) Surge suppressor Zener diode
Y8
Supply current for connected
1.0A or lower/common
X7
device
X6
Wiring method for common 16 points/common (input: 3-wire terminal block type, output: 2-wire terminal block type)
X5
Number of occupied stations 32-point assignment/station (16 points used)
X4
Module power Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
X3
supply Current 50mA or lower (at 24VDC and all points ON) Y8 9 A B C D E F
AJ65SBTB32-16DT2
X2
Noise voltage 500Vp-p, noise width 1µs,
Noise immunity
X1
noise frequency 25 to 60Hz (DC type noise simulator condition) X0
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
PW L RUN L ERR. X0 1 2 3 4 5 6 7
10MΩ or higher between all DC external terminals and ground (500VDC insulation resistance
Insulation resistance
(FG)
24G
tester)
+24V
Weight 0.25kg
DB
DA
6 - 15 6 - 15
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
TB2 DB
1 DA TB3 DG
2 DB TB4 SLD
3 DG Insulation TB5 +24V
4 SLD
TB6 (FG)
5 +24V
6 FG
TB7 24G
7 24G TB8 X0
Module power supply TB9 COM+
Black TB10 X1
3-wire sensor 8 X0
Brown TB11 COM-
9 COM+
Blue TB12 X2
10 X1
11 COM- TB13 COM+
12 X2 TB14 X3
13 COM+
TB15 COM-
14 X3
15 COM-
TB16 X4
16 X4 TB17 COM+
17 COM+ TB18 X5
18 X5 TB19 COM-
19 COM- TB20 X6
20 X6
TB21 COM+
21 COM+
22 X7 TB22 X7
Load 23 COM- TB23 COM-
24 Y8 TB24 Y8
25 COM+ TB25 COM+
26 Y9
TB26 Y9
27 COM+
28 YA
TB27 COM+
29 COM+ TB28 YA
30 YB TB29 COM+
31 COM+ TB30 YB
32 YC TB31 COM+
33 COM+
TB32 YC
34 YD
35 COM+ TB33 COM+
36 YE TB34 YD
Load 37 COM+ TB35 COM+
38 YF TB36 YE
39 COM+
TB37 COM+
40 DC24V
41 DC24G
TB38 YF
External power supply Constant-voltage circuit TB39 COM+
for output part TB40 DC24V
TB41 DC24G
6 - 16 6 - 16
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
6 - 17 6 - 17
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
TB2 DB
TB3 DG
TB4 SLD
1 DA
2 DB
TB5 +24V
3 DG TB6 (FG)
Insulation
4 SLD TB7 24G
5 +24V
TB8 X0
6 FG
7 24G TB9 COM+
Module power supply
TB10 X1
Black TB11 COM-
3-wire sensor 8 X0 TB12 X2
Brown
9 COM+
Blue TB13 COM+
10 X1
Blue 11 COM- TB14 X3
2-wire sensor
Brown 12 X2 TB15 COM-
13 COM+
14 X3
TB16 X4
15 COM- TB17 COM+
16 X4 TB18 X5
17 COM+
TB19 COM-
18 X5
19 COM- TB20 X6
20 X6 TB21 COM+
21 COM+
TB22 X7
22 X7
23 COM- TB23 COM-
Load
24 Y8 TB24 Y8
25 COM+ TB25 COM+
26 Y9
27 COM+
TB26 Y9
28 YA TB27 COM+
29 COM+ TB28 YA
30 YB
TB29 COM+
31 COM+
32 YC TB30 YB
33 COM+ TB31 COM+
34 YD
TB32 YC
35 COM+
36 YE TB33 COM+
Load 37 COM+ TB34 YD
38 YF TB35 COM+
39 COM+
External power supply TB36 YE
40 DC24V
for output part
41 DC24G TB37 COM+
Constant-voltage circuit
TB38 YF
TB39 COM+
TB40 DC24V
TB41 DC24G
6 - 18 6 - 18
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
6 - 19 6 - 19
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
TB2 DB
TB3 DG
1 DA TB4 SLD
2 DB TB5 +24V
3 DG Insulation TB6 (FG)
4 SLD
5 +24V TB7 24G
6 FG TB8 X0
7 24G TB9 COM+
Module power supply
TB10 X1
Black TB11 COM-
3-wire sensor 8 X0
Brown TB12 X2
9 COM+
Blue
10 X1 TB13 COM+
Blue 11 COM-
2-wire sensor TB14 X3
Brown 12 X2
13 COM+ TB15 COM-
14 X3 TB16 X4
15 COM-
TB17 COM+
16 X4
17 COM+ TB18 X5
18 X5 TB19 COM-
19 COM- TB20 X6
20 X6
21 COM+
TB21 COM+
22 X7 TB22 X7
Load
23 COM- TB23 COM-
24 Y8
TB24 Y8
25 COM+
26 Y9 TB25 COM+
27 COM+ TB26 Y9
28 YA
TB27 COM+
29 COM+
30 YB TB28 YA
31 COM+ TB29 COM+
32 YC TB30 YB
33 COM+
34 YD
TB31 COM+
35 COM+ TB32 YC
36 YE TB33 COM+
37 COM+
Load TB34 YD
38 YF
39 COM+ TB35 COM+
External power supply for 40 DC12V TB36 YE
output part 41 DC12G
Constant-voltage circuit TB37 COM+
TB38 YF
TB39 COM+
TB40 DC12V
TB41 DC12G
6 - 20 6 - 20
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
6 - 21 6 - 21
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
TB2 DB
TB3 DG
1 DA
TB4 SLD
2 DB
3 DG TB5 +24V
Insulation
4 SLD TB6 (FG)
5 +24V
TB7 24G
6 FG
7 24G TB8 X0
Module power supply TB9 COM1A
TB10 X1
Black TB11 COM1B
3-wire sensor 8 X0
Brown TB12 X2
9 COM1A
Blue
10 X1 TB13 COM1A
2-wire sensor Blue 11 COM1B TB14 X3
Brown 12 X2
TB15 COM1B
13 COM1A
14 X3 TB16 X4
15 COM1B TB17 COM1A
16 X4
TB18 X5
17 COM1A
18 X5 TB19 COM1B
19 COM1B TB20 X6
20 X6 TB21 COM1A
21 COM1A
22 X7
TB22 X7
23 COM1B TB23 COM1B
24 DC24A TB24 DC24A
25 DC24B
Load TB25 DC24B
26 Y8
27 COM2B TB26 Y8
Load
28 Y9 TB27 COM2B
29 COM2B
Load TB28 Y9
30 YA
31 COM2B TB29 COM2B
Load
External power supply 32 YB TB30 YA
for output part 33 COM2A
Load TB31 COM2B
34 YC
35 COM3B
TB32 YB
Load
36 YD TB33 COM2A
37 COM3B TB34 YC
Load
38 YE
TB35 COM3B
39 COM3B
Load
External power supply 40 YF TB36 YD
for output part 41 COM3A TB37 COM3B
TB38 YE
TB39 COM3B
TB40 YF
TB41 COM3A
6 - 22 6 - 22
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
6 - 23 6 - 23
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
TB2 DB
1 DA
TB3 DG
2 DB
TB4 SLD
3 DG Insulation
4 SLD TB5 +24V
5 +24V TB6 (FG)
6 FG TB7 24G
7 24G
Module power supply TB8 X0
TB9 COM1A
TB10 X1
Black
3-wire sensor 8 X0 TB11 COM1B
Brown
Blue
9 COM1A TB12 X2
10 X1
TB13 COM1A
Blue 11 COM1B
2-wire sensor TB14 X3
Brown 12 X2
13 COM1A TB15 COM1B
14 X3 TB16 X4
15 COM1B
TB17 COM1A
16 X4
TB18 X5
17 COM1A
18 X5 TB19 COM1B
19 COM1B TB20 X6
20 X6 TB21 COM1A
21 COM1A
TB22 X7
22 X7
23 COM1B TB23 COM1B
24 DC24A TB24 DC24A
25 DC24B TB25 DC24B
Load
26 Y8
TB26 Y8
27 COM2B
Load TB27 COM2B
28 Y9
29 COM2B TB28 Y9
Load
30 YA TB29 COM2B
31 COM2B
External power supply Load TB30 YA
32 YB
for output part TB31 COM2B
33 COM2A
Load
34 YC TB32 YB
35 COM3B TB33 COM2A
Load
36 YD
TB34 YC
37 COM3B
Load TB35 COM3B
38 YE
39 COM3B TB36 YD
Load
External power supply 40 YF TB37 COM3B
41 COM3A TB38 YE
for output part
TB39 COM3B
TB40 YF
TB41 COM3A
6 - 24 6 - 24
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
Y1F COM-
Protection function
Y1E COM+
B RATE
40 20 10 8 4 2 1 4 2 1
protection, overheat protection
OFF→ON 1.5ms or less (at 24VDC) OFF→ON 0.5ms or less
Y1D
STATION NO.
Y1C
Response time Response time
Y1B
ON→OFF 1.5ms or less (at 24VDC) ON→OFF 1.5ms or less (resistive load)
Y1A
Y19
19.2 to 26.4VDC
Y18
ON
External power Voltage
Y17
(ripple ratio: within 5%)
Y16
supply for
Y15
30mA or lower (24VDC/common),
Y14
output part Current
Y13
excluding external load current
Y12
Y18 19 1A1B 1C1D1E 1F
Y11
Input type Positive common (sink type) Surge suppressor Zener diode
Y10
XF
Wiring method for common 32 points/common (1-wire, terminal block type)
XE
XD
Number of occupied stations 32-point assignment/station (32 points used)
XC
Y10 11 12 13 14 15 16 17
XB
Module power Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
XA
X9
supply Current 60mA or lower (at 24VDC and all points ON)
X8
X7
Noise voltage 500Vp-p, noise width 1µs,
X6
X8 9 A B C D E F
X5
Noise immunity
noise frequency 25 to 60Hz (DC type noise simulator condition)
X4
AJ65SBTB1-32DT
X3
X2
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
X1
X0
10MΩ or higher between all DC external terminals and ground (500VDC insulation resistance
PW L RUN L ERR. X0 1 2 3 4 5 6 7
Insulation resistance
tester)
(FG)
24G
Weight 0.25kg
DB
6 - 25 6 - 25
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
TB2 DB
1 DA
2 DB
TB3 DG
3 DG TB4 SLD
Insulation
4 SLD TB5 +24V
5 +24V TB6 (FG)
6 FG TB7 24G
7 24G TB8 X0
Module power supply
TB9 X1
8 X0
TB10 X2
9 X1
10 X2 TB11 X3
11 X3 TB12 X4
12 X4 TB13 X5
13 X5 TB14 X6
14 X6 TB15 X7
15 X7
TB16 X8
16 X8
17 X9
TB17 X9
18 XA TB18 XA
19 XB TB19 XB
20 XC TB20 XC
21 XD TB21 XD
22 XE TB22 XE
23 XF
Load TB23 XF
24 Y10
25 Y11
TB24 Y10
26 Y12 TB25 Y11
27 Y13 TB26 Y12
28 Y14 TB27 Y13
29 Y15 TB28 Y14
30 Y16 TB29 Y15
31 Y17
TB30 Y16
32 Y18
33 Y19
TB31 Y17
34 Y1A TB32 Y18
35 Y1B TB33 Y19
36 Y1C TB34 Y1A
Load
37 Y1D TB35 Y1B
38 Y1E TB36 Y1C
39 Y1F
TB37 Y1D
40 COM+
External power supply 41 COM-
TB38 Y1E
for output part TB39 Y1F
Load power supply Constant-voltage circuit TB40 COM+
TB41 COM-
Load
External power supply for output part
40 COM+ and load power supply (common)
41 COM-
6 - 26 6 - 26
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
Y1F COM-
Protection function
Y1E COM+
B RATE
40 20 10 8 4 2 1 4 2 1
protection, overheat protection
Y1D
OFF→ON 0.2ms or less (at 24VDC) Response OFF→ON 0.5ms or less
STATION NO.
Y1C
Response time
Y1B
ON→OFF 0.2ms or less (at 24VDC) time ON→OFF 1.5ms or less (resistive load)
Y1A
Y19
19.2 to 26.4VDC
Y18
External Voltage
ON
Y17
(ripple ratio: within 5%)
power
Y16
Y15
24.2mA or lower
supply for
Y14
Y13
Current (at 24VDC and all points ON),
output part
Y12
excluding external load current
Y11
Y10
Input type Positive common (sink type) Surge suppressor Zener diode
XF
XE
Wiring method for common 32 points/common (1-wire, terminal block type)
XD
XC
Number of occupied stations 32-point assignment/station (32 points used)
XB
XA
Module power Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
X9
X8
supply Current 60mA or lower (at 24VDC and all points ON)
X7
X6
X8 9 A B C D E F
X5
Noise voltage 500Vp-p, noise width 1µs,
Noise immunity
X4
AJ65SBTB1-32DT1
noise frequency 25 to 60Hz (DC type noise simulator condition)
X3
X2
X1
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
X0
PW L RUN L ERR. X0 1 2 3 4 5 6 7
10MΩ or higher between all DC external terminals and ground (500VDC insulation resistance
Insulation resistance
tester)
(FG)
24G
Weight 0.25kg
DG
DB
DA
6 - 27 6 - 27
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
1 DA TB2 DB
2 DB TB3 DG
3 DG Insulation TB4 SLD
4 SLD
TB5 +24V
5 +24V
6 FG TB6 (FG)
7 24G TB7 24G
Module power supply TB8 X0
8 X0 TB9 X1
9 X1 TB10 X2
10 X2 TB11 X3
11 X3
TB12 X4
12 X4
13 X5
TB13 X5
14 X6 TB14 X6
15 X7 TB15 X7
16 X8 TB16 X8
17 X9 TB17 X9
18 XA TB18 XA
19 XB
TB19 XB
20 XC
21 XD
TB20 XC
22 XE TB21 XD
23 XF TB22 XE
Load
24 Y10 TB23 XF
25 Y11 TB24 Y10
26 Y12 TB25 Y11
27 Y13
TB26 Y12
28 Y14
29 Y15
TB27 Y13
30 Y16 TB28 Y14
31 Y17 TB29 Y15
32 Y18 TB30 Y16
33 Y19 TB31 Y17
34 Y1A TB32 Y18
35 Y1B
TB33 Y19
36 Y1C
37 Y1D
TB34 Y1A
Load
38 Y1E TB35 Y1B
39 Y1F TB36 Y1C
40 COM+ TB37 Y1D
External power supply 41 COM- TB38 Y1E
for output part
Constant-voltage circuit TB39 Y1F
Load power supply
TB40 COM+
Load
TB41 COM-
External power supply for output part
40 COM+ and load power supply (common)
41 COM-
6 - 28 6 - 28
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
Y1F COM-
Protection function None
Y1E COM+
B RATE
40 20 10 8 4 2 1 4 2 1
OFF→ON 1.5ms or less (at 24VDC) OFF→ON 0.5ms or less
Response time Response time
Y1D
STATION NO.
Y1C
ON→OFF 1.5ms or less (at 24VDC) ON→OFF 1.5ms or less (resistive load)
Y1B
19.2 to 26.4VDC
Y1A
Voltage
Y19
External power (ripple ratio: within 5%)
Y18
ON
Y17
supply for 30mA or lower
Y16
Y15
output part Current (at 24VDC and all points ON),
Y14
Y13
excluding external load current
Y12
Y10 11 12 13 14 15 16 17 Y18 19 1A1B 1C1D1E 1F
Y11
Input type Positive common (sink type) Surge suppressor Zener diode
Y10
XF
Wiring method for common 32 points/common (1-wire, terminal block type)
XE
XD
Number of occupied stations 32-point assignment/station (32 points used)
XC
XB
Module power Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
XA
X9
supply Current 60mA or lower (at 24VDC and all points ON)
X8
X7
Noise voltage 500Vp-p, noise width 1µs,
X6
Noise immunity
X8 9 A B C D E F
X5
noise frequency 25 to 60Hz (DC type noise simulator condition)
X4
AJ65SBTB1-32DT2
X3
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
X2
X1
10MΩ or higher between all DC external terminals and ground (500VDC insulation resistance
X0
Insulation resistance
PW L RUN L ERR. X0 1 2 3 4 5 6 7
tester)
(FG)
24G
Weight 0.25kg
SLD
Communication
[Transmission circuit, module power supply, FG]
part, module
M3×5.2 screw (tightening torque range:0.59 to 0.88N•m)
External power supply part
Applicable solderless terminal: 2 or less
connection
34-point direct-mount terminal block
system I/O power supply
[I/O power supply, I/O signal]
part,
M3×5.2 screw (tightening torque range:0.59 to 0.88N•m)
I/O part
Applicable solderless terminal: 2 or less
M4 screw with plain washer finished round (tightening torque range: 0.78 to 1.08N•m)
Module mounting screw
Mountable with a DIN rail in 6 orientations
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
y RAV1.25-3 (compliant with JIS C 2805)
[Applicable wire size: 0.3 to 1.25mm2]
Applicable solderless terminal
y V2-MS3, RAP2-3SL, TGV2-3N
[Applicable wire size: 1.25 to 2.0mm2]
Accessory User’s manual
6 - 29 6 - 29
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
TB2 DB
1 DA
2 DB TB3 DG
3 DG Insulation TB4 SLD
4 SLD TB5 +24V
5 +24V TB6 (FG)
6 FG TB7 24G
7 24G
Module power supply TB8 X0
TB9 X1
8 X0 TB10 X2
9 X1 TB11 X3
10 X2
TB12 X4
11 X3
12 X4 TB13 X5
13 X5 TB14 X6
14 X6 TB15 X7
15 X7 TB16 X8
16 X8 TB17 X9
17 X9
TB18 XA
18 XA
19 XB
TB19 XB
20 XC TB20 XC
21 XD TB21 XD
22 XE TB22 XE
Load
23 XF TB23 XF
24 Y10
TB24 Y10
25 Y11
26 Y12
TB25 Y11
27 Y13 TB26 Y12
28 Y14 TB27 Y13
29 Y15 TB28 Y14
30 Y16 TB29 Y15
31 Y17
TB30 Y16
32 Y18
33 Y19
TB31 Y17
34 Y1A TB32 Y18
35 Y1B TB33 Y19
36 Y1C TB34 Y1A
Load 37 Y1D TB35 Y1B
38 Y1E
TB36 Y1C
39 Y1F
TB37 Y1D
External power supply 40 COM+
41 COM- TB38 Y1E
for output part
TB39 Y1F
Load power supply TB40 COM+
Constant-voltage circuit
TB41 COM-
Load
External power supply for output part
40 COM+ and load power supply (common)
41 COM-
6 - 30 6 - 30
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
6 - 31 6 - 31
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
TB2 DB
1 DA
2 DB TB3 DG
3 DG Insulation TB4 SLD
4 SLD TB5 +24V
5 +24V
TB6 (FG)
6 FG
7 24G TB7 24G
Module power supply TB8 X0
TB9 X1
8 X0 TB10 X2
9 X1
TB11 X3
10 X2
11 X3 TB12 X4
12 X4 TB13 X5
13 X5 TB14 X6
14 X6
TB15 X7
15 X7
16 X8 TB16 X8
17 X9 TB17 X9
18 XA TB18 XA
19 XB
TB19 XB
20 XC
21 XD TB20 XC
22 XE TB21 XD
23 XF TB22 XE
Load
24 Y10
TB23 XF
25 Y11
26 Y12 TB24 Y10
27 Y13 TB25 Y11
28 Y14 TB26 Y12
29 Y15
TB27 Y13
30 Y16
31 Y17 TB28 Y14
32 Y18 TB29 Y15
33 Y19 TB30 Y16
34 Y1A
TB31 Y17
35 Y1B
36 Y1C TB32 Y18
Load
37 Y1D TB33 Y19
38 Y1E TB34 Y1A
39 Y1F
TB35 Y1B
40 COM+
External power supply 41 COM- TB36 Y1C
for output part
TB37 Y1D
Load power supply TB38 Y1E
Constant-voltage circuit TB39 Y1F
TB40 COM+
Load TB41 COM-
External power supply for output part
40 COM+ and load power supply (common)
41 COM-
6 - 32 6 - 32
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
Y1F COM-
Input resistance Approx. 4.7kΩ
Y1E COM+
B RATE
40 20 10 8 4 2 1 4 2 1
Protection function None
Y1D
OFF→ON 0.2ms or less (at 24VDC) OFF→ON 0.5ms or less
STATION NO.
Y1C
Response time Response time
Y1B
ON→OFF 0.2ms or less (at 24VDC) ON→OFF 1.5ms or less (resistive load)
Y1A
19.2 to 26.4VDC
Y19
Voltage
Y18
ON
External power (ripple ratio: within 5%)
Y17
Y16
supply for 24.2mA or lower
Y15
Y14
output part Current (at 24VDC and all points ON),
Y13
Y12
excluding external load current
Y11
Input type Positive common (sink type) Surge suppressor Zener diode
Y10
XF
Wiring method for common 32 points/common (1-wire, terminal block type)
XE
XD
Number of occupied stations 32-point assignment/station (32 points used)
XC
XB
Module power Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
XA
X9
supply Current 60mA or lower (at 24VDC and all points ON)
X8
X7
Noise voltage 500Vp-p, noise width 1µs,
X6
Noise immunity
X8 9 A B C D E F
X5
noise frequency 25 to 60Hz (DC type noise simulator condition)
X4
AJ65SBTB1-32DT3
X3
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
X2
10MΩ or higher between all DC external terminals and ground (500VDC insulation resistance
X1
Insulation resistance
X0
tester)
PW L RUN L ERR. X0 1 2 3 4 5 6 7
Weight 0.25kg
DG +24V
SLD
6 - 33 6 - 33
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
TB2 DB
1 DA
2 DB TB3 DG
3 DG TB4 SLD
Insulation
4 SLD TB5 +24V
5 +24V TB6 (FG)
6 FG TB7 24G
7 24G
Module power supply TB8 X0
TB9 X1
8 X0 TB10 X2
9 X1 TB11 X3
10 X2
TB12 X4
11 X3
12 X4 TB13 X5
13 X5 TB14 X6
14 X6 TB15 X7
15 X7 TB16 X8
16 X8 TB17 X9
17 X9
TB18 XA
18 XA
19 XB
TB19 XB
20 XC TB20 XC
21 XD TB21 XD
22 XE TB22 XE
Load
23 XF TB23 XF
24 Y10
TB24 Y10
25 Y11
26 Y12
TB25 Y11
27 Y13 TB26 Y12
28 Y14 TB27 Y13
29 Y15 TB28 Y14
30 Y16 TB29 Y15
31 Y17
TB30 Y16
32 Y18
TB31 Y17
33 Y19
34 Y1A TB32 Y18
35 Y1B TB33 Y19
36 Y1C TB34 Y1A
Load 37 Y1D TB35 Y1B
38 Y1E
TB36 Y1C
39 Y1F
TB37 Y1D
40 COM+
External power supply TB38 Y1E
41 COM-
for output part
TB39 Y1F
Load power supply TB40 COM+
Constant-voltage circuit TB41 COM-
Load
External power supply for output part
40 COM+ and load power supply (common)
41 COM-
6 - 34 6 - 34
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
6 - 35 6 - 35
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
1 DA TB2 DB
2 DB TB3 DG
3 DG Insulation TB4 SLD
4 SLD
TB5 +24V
5 +24V
6 FG TB6 (FG)
7 24G TB7 24G
Module power supply
TB8 X0
TB9 X1
8 X0
TB10 X2
9 X1
10 X2 TB11 X3
11 X3 TB12 X4
12 X4 TB13 X5
13 X5
TB14 X6
14 X6
15 X7 TB15 X7
16 X8 TB16 X8
17 X9 TB17 X9
18 XA
TB18 XA
19 XB
20 XC TB19 XB
21 XD TB20 XC
22 XE TB21 XD
23 XF
Load TB22 XE
24 Y10
25 Y11 TB23 XF
26 Y12 TB24 Y10
27 Y13 TB25 Y11
28 Y14
TB26 Y12
29 Y15
30 Y16 TB27 Y13
31 Y17 TB28 Y14
32 Y18 TB29 Y15
33 Y19
TB30 Y16
34 Y1A
35 Y1B TB31 Y17
36 Y1C TB32 Y18
Load 37 Y1D TB33 Y19
38 Y1E
TB34 Y1A
39 Y1F
40 COM+ TB35 Y1B
External power supply
41 COM- TB36 Y1C
for output part
TB37 Y1D
Load power supply
TB38 Y1E
Constant-voltage circuit TB39 Y1F
TB40 COM+
Load
TB41 COM-
External power supply for output part
40 COM+ and load power supply (common)
41 COM-
6 - 36 6 - 36
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
40 20 10 8 4 2 1
ON→OFF 1.5ms or less (at 24VDC) ON→OFF 1.5ms or less (resistive load)
STATION NO.
19.2 to 26.4VDC
Voltage
External power (ripple ratio: within 5%)
Y19
ON
supply for 10mA or lower
Y17
output part Current (TYP. 24VDC/common),
Y15
excluding external load current
Y13
Input type Negative common (source type) Surge suppressor Zener diode
Y18 19 1A 1B 1C 1D 1E 1F
Y11
Wiring method for common 32 points/common (1-wire, terminal block type)
XF
Number of occupied stations 32-point assignment/station (32 points used)
XE
XD
Module power Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
XC
Y10 11 12 13 14 15 16 17
XB
supply Current 50mA or lower (at 24VDC and all points ON)
XA
X9
Noise voltage 500Vp-p, noise width 1µs,
X8
Noise immunity
X7
noise frequency 25 to 60Hz (DC type noise simulator condition)
X6
X8 9 A B C D E F
X5
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
X4
AJ65SBTB1-32DTE1
X3
10MΩ or higher between all DC external terminals and ground (500VDC insulation resistance
X2
Insulation resistance
tester)
X1
X0
PW L RUN L ERR. X0 1 2 3 4 5 6 7
6 - 37 6 - 37
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
Terminal number Signal name
TB1 DA
TB2 DB
1 DA TB3 DG
2 DB TB4 SLD
3 DG TB5 +24V
Insulation
4 SLD
TB6 (FG)
5 +24V
6 FG TB7 24G
7 24G TB8 X0
Module power supply
TB9 X1
8 X0
TB10 X2
9 X1
10 X2
TB11 X3
11 X3 TB12 X4
12 X4 TB13 X5
13 X5 TB14 X6
14 X6 TB15 X7
15 X7
TB16 X8
16 X8
17 X9 TB17 X9
18 XA TB18 XA
19 XB TB19 XB
20 XC TB20 XC
21 XD
TB21 XD
22 XE
23 XF TB22 XE
Load
24 Y10 TB23 XF
25 Y11 TB24 Y10
26 Y12 TB25 Y11
27 Y13
TB26 Y12
28 Y14
29 Y15
TB27 Y13
30 Y16 TB28 Y14
31 Y17 TB29 Y15
32 Y18 TB30 Y16
33 Y19
TB31 Y17
34 Y1A
35 Y1B
TB32 Y18
36 Y1C TB33 Y19
37 Y1D TB34 Y1A
Load power supply 38 Y1E TB35 Y1B
39 Y1F TB36 Y1C
40 COM+
TB37 Y1D
41 COM-
External power supply Constant-voltage circuit TB38 Y1E
for output part TB39 Y1F
TB40 COM+
Load
TB41 COM-
6 - 38 6 - 38
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
6 - 39 6 - 39
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
Terminal Signal Terminal Signal
number name number name
TB1 DA TB26 Empty
TB2 DG TB27 Empty
TB3 DB Insulation TB28 +24V
1 DA Empty 26
TB4 Empty 2 DG Empty 27
TB29 CTL+
TB5 SLD 3 DB +24V 28
24VDC TB30 (FG)
4 Empty CTL+ 29
TB6 Empty 5 SLD FG 30 TB31 CTLG
6 Empty CTLG 31
TB7 24G TB32 24G
7 24G 24G 32
TB8 X0 Module TB33 Y10
Constant-voltage
power supply
circuit
TB9 X1 TB34 Y11
TB10 X2 TB35 Y12
Load
Y10 33
TB11 X3 8 X0 TB36 Y13
9 X1 Y11 34
TB12 X4 10 X2 Y12 35 TB37 Y14
11 X3 Y13 36
TB13 X5 Y14 37
TB38 Y15
12 X4
TB14 X6 13 X5 Y15 38 TB39 Y16
14 X6 Y16 39
TB15 X7 15 X7 Y17 40
Load TB40 Y17
TB16 COM1 16 COM1 COM3 41
Load TB41 COM3
17 X8 Y18 42
TB17 X8 18 X9 Y19 43 TB42 Y18
19 XA Y1A 44
TB18 X9 TB43 Y19
20 XB Y1B 45
TB19 XA 21 XC Y1C 46 TB44 Y1A
22 XD Y1D 47
TB20 XB 23 XE Y1E 48
TB45 Y1B
Load
TB21 XC 24 XF Y1F 49 TB46 Y1C
25 COM2 COM4 50
TB22 XD 24VDC TB47 Y1D
TB23 XE TB48 Y1E
TB24 XF TB49 Y1F
TB25 COM2 TB50 COM4
6 - 40 6 - 40
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
6 - 41 6 - 41
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
Terminal Signal Terminal Signal
number name number name
TB1 DA TB26 Empty
TB2 DG TB27 Empty
TB3 DB TB28 +24V
Insulation
TB4 Empty 1 DA Empty 26 TB29 CTL+
2 DG Empty 27
24VDC (FG)
TB5 SLD 3 DB CTL+ +24V 28 TB30
4 Empty CTL+ 29
TB6 Empty TB31 CTLG
5 SLD FG 30
TB7 24G 6 Empty CTLG CTLG 31 TB32 24G
7 24G 24G 32
TB8 X0 Module power supply TB33 Y10
TB9 X1 Load TB34 Y11
8 X0 CTL+ Y10 33
TB10 X2 9 X1 Y11 34 TB35 Y12
10 X2 Y12 35
TB11 X3 TB36 Y13
11 X3 Y13 36
TB12 X4 12 X4 Y14 37 TB37 Y14
13 X5 Y15 38
TB13 X5 14 X6 Y16 39 TB38 Y15
Load
TB14 X6 15 X7
CTLG Y17 40 TB39 Y16
16 COM1 COM3 41
Load
TB15 X7 17 X8 CTL+ Y18 42 TB40 Y17
18 X9 Y19 43
TB16 COM1 19 XA Y1A 44
TB41 COM3
TB17 X8 20 XB Y1B 45 TB42 Y18
21 XC Y1C 46
TB18 X9 22 XD Y1D 47 TB43 Y19
23 XE Y1E 48
TB19 XA 24 XF Y1F 49
Load TB44 Y1A
CTLG
TB20 XB 25 COM2 COM4 50 TB45 Y1B
TB21 XC TB46 Y1C
24VDC
TB22 XD TB47 Y1D
TB23 XE TB48 Y1E
TB24 XF TB49 Y1F
TB25 COM2 TB50 COM4
6 - 42 6 - 42
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
YF
15mA or lower
supply for
YD YE
Current (at 24VDC and all points ON),
output part
excluding external load current
YC
NC
Input type Positive common (sink type) Surge suppressor Zener diode
YB
YA
Supply current for connected
1.0A or lower/common
Y9
device
COM+
Y8
AJ65VBTS32-16DT
16 points/common
Wiring method for common
X7
(input: 3-wire spring clamp terminal block type, output: 2-wire spring clamp terminal block type)
X6
Number of occupied stations 32-point assignment/station (16 points used)
X5
Module power Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
X4
COM-
X3
supply Current 40mA or lower (at 24VDC and all points ON)
Noise voltage 500Vp-p, noise width 1µs, X2
Noise immunity
X1
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground COM+
COM-
NC
10MΩ or higher between all DC external terminals and ground (500VDC insulation resistance
Insulation resistance
tester)
D
8 9 A B C D E F
0 1 2 3 4 5 6 7
Weight 0.24kg
C
part
1 2 4 1 2 4 8 1020 40
connection One-touch connector for power supply and FG [Module power supply, FG]
system Power supply part 5-pin IDC plug is sold separately: A6CON-PW5P, A6CON-PW5P-SOD
<Optional> Online connector for power supply: A6CON-PWJ5P
I/O part 2-piece spring clamp terminal block [I/O power supply, I/O signals]
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
Connector for Applicable cable:
communication FANC-110SBH, FA-CBL200PSBH, CS-110
2
0.66 to 0.98mm (AWG18)
Connector for
[φ2.2 to 3.0mm (A6CON-PW5P), φ2.0 to 2.3mm (A6CON-PW5P-SOD)]
power supply and
Wire diameter: 0.16mm or more
FG
Insulating coating material: PVC (heat-resistant)
Spring clamp 2
Applicable Stranded wire 0.08 to 1.5mm (AWG28 to 16) 1
terminal block for
wire size Wire strip length: 8 to 11mm
I/O
2
TE0.5 [Applicable wire size: 0.5mm ]
TE0.75 [Applicable wire size: 0.75mm2]
Applicable
TE1 [Applicable wire size: 0.9 to 1.0mm2]
solderless
TE1.5 [Applicable wire size: 1.25 to 1.5mm2]
terminal
FA-VTC125T9 [Applicable wire size: 0.3 to 1.65mm2]
FA-VTCW125T9 [Applicable wire size: 0.3 to 1.65mm2]
Accessory User’s manual, Holding fixtures for screw installation
6 - 43 6 - 43
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
1:Attach an unwired connector plug to an unused one-touch connector for power supply and FG.
6 - 44 6 - 44
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
1:Attach an unwired connector plug to an unused one-touch connector for power supply and FG.
Pin layout
6 - 45 6 - 45
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
X9 XA XB XC XD XE XF NC Y10 Y11 Y12 Y13 Y14 Y15 Y16 Y17 Y18 Y19 Y1A Y1B Y1C Y1D Y1E Y1F
ON→OFF 1.5ms or less (at 24VDC) Protection function None
OFF→ON 1ms or less
Response time
ON→OFF 1ms or less (resistive load)
10.2 to 26.4VDC
Voltage
External power (ripple ratio: within 5%)
supply for
COM2+
30mA or lower
NC
output part Current (at 24VDC and all points ON),
excluding external load current
16 points/common 16 points/common
Wiring method for common (3-wire, spring clamp terminal Wiring method for common (2-wire, spring clamp terminal block
block type) type)
AJ65VBTS32-32DT
Input type Positive common (sink type) Surge suppressor Zener diode
COM2+
COM2-
Supply current for connected
1.0A or lower/common
device
Number of occupied stations 32-point assignment/station (32 points used)
Module power Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
supply Current 50mA or lower (at 24VDC and all points ON)
Noise voltage 500Vp-p, noise width 1µs,
Noise immunity
COM1+
COM1-
X8
noise frequency 25 to 60Hz (DC type noise simulator condition)
X7
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
X6
10MΩ or higher between all DC external terminals and ground (500VDC insulation resistance
X5
Insulation resistance
X4
tester)
X3
Weight 0.41kg
X1
X0
COM1-
Communication
NC
connection One-touch connector for power supply and FG [Module power supply, FG]
L ERR.
Power supply
system
C
part
<Optional> Online connector for power supply: A6CON-PWJ5P
B
ON
B RATESTATION NO.
I/O part 2-piece spring clamp terminal block [I/O power supply, I/O signals]
1 2 4 1 2 4 8 102040
CON A
6 - 46 6 - 46
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
CONA
LINK CABLE
1
2
1 DA Pin number Signal name
(IN) 2 DB
3
4
3
4
DG
Empty
1 DA
5
5 SLD
2 DB
CONB
LINK CABLE
1
2
1 DA CON A, B 3 DG
2 DB
(OUT) 3
4
3
4
DG
Empty
4 Empty
5
One-touch connector
5 SLD
5 SLD
for communication
1
CONC
1 FG
Insulation 1 (FG)
UNIT POWER CABLE(IN)
2
3
2
3
+24V(UNIT)
+24G(UNIT)
2 +24V (UNIT)
4
5
4
5
Empty
Empty
CON C, D 3 24G (UNIT)
UNIT POWER CABLE(OUT)
1
COND
1 FG
4 Empty
2 24V(UNIT)
3
2
3 24G(UNIT) 5 Empty
4 Empty
5
4
5 Empty Terminal block
One-touch connector for
power supply and FG
1
Column A Column B Column C
TB1A Empty
TB1B COM1+ 1 Empty 1 COM1+ 1 COM1-
TB1C COM1-
TB2A
TB2B
X0
COM1+
2 X0 2 COM1+ 2 COM1-
TB2C
TB3A
COM1-
X1
3 X1 3 COM1+ 3 COM1-
TB3B
TB3C
COM1+
COM1- 4 X2 4 COM1+ 4 COM1-
TB4A X2
TB4B COM1+ 5 X3 5 COM1+ 5 COM1-
TB4C COM1-
TB5A X3 6 X4 6 COM1+ 6 COM1-
TB5B COM1+
TB5C COM1- 7 X5 7 COM1+ 7 COM1-
TB6A X4
TB6B COM1+ 8 X6 8 COM1+ 8 COM1-
TB6C COM1-
TB7A
TB7B
X5
COM1+
9 X7 9 COM1+ 9 COM1-
TB7C
TB8A
COM1-
X6
10 X8 10 COM1+ 10 COM1-
TB8B
TB8C
COM1+
COM1-
11 X9 11 COM1+ 11 COM1-
TB9A X7
TB9B COM1+ 12 XA 12 COM1+ 12 COM1-
TB9C COM1-
TB10A X8 13 XB 13 COM1+ 13 COM1-
TB10B COM1+
TB10C COM1- 14 XC 14 COM1+ 14 COM1-
TB11A X9
TB11B COM1+ 15 XD 15 COM1+ 15 COM1-
TB11C COM1-
TB12A XA 16 XE 16 COM1+ 16 COM1-
TB12B COM1+
TB12C
TB13A
COM1-
XB
17 XF 17 COM1+ 17 COM1-
TB13B
TB13C
COM1+
COM1-
18 Empty 18 COM2+ 18 COM2-
TB14A XC
TB14B COM1+ 19 Y10 19 COM2+ 19 Empty
TB14C COM1-
TB15A XD 20 Y11 20 COM2+ 20 Empty
TB15B COM1+
TB15C COM1- 21 Y12 21 COM2+ 21 Empty
TB16A XE
TB16B COM1+ 22 Y13 22 COM2+ 22 Empty
TB16C COM1-
TB17A
TB17B
XF
COM1+
23 Y14 23 COM2+ 23 Empty
External power supply for output
TB17C
TB18A
COM1-
Empty
24 Y15 24 COM2+ 24 Empty
Constant-
TB18B
TB18C
COM2+
COM1-
voltage circuit
25 Y16 25 COM2+ 25 Empty
Load
TB19A Y10
TB19B COM2+ 26 Y17 26 COM2+ 26 Empty
TB19C Empty
TB20A Y11 27 Y18 27 COM2+ 27 Empty
TB20B COM2+
TB20C Empty 28 Y19 28 COM2+ 28 Empty
TB21A Y12
TB21B COM2+ 29 Y1A 29 COM2+ 29 Empty
TB21C Empty
TB22A Y13
TB22B COM2+
30 Y1B 30 COM2+ 30 Empty
TB22C
TB23A
Empty
Y14
31 Y1C 31 COM2+ 31 Empty
TB23B
TB23C
COM2+
Empty 32 Y1D 32 COM2+ 32 Empty
TB24A Y15
TB24B COM2+ 33 Y1E 33 COM2+ 33 Empty
TB24C Empty
TB25A Y16 34 Y1F 34 COM2+ 34 Empty
TB25B COM2+
TB25C Empty
TB26A Y17
TB26B COM2+
TB26C Empty
TB27A Y18
TB27B COM2+
TB27C Empty
TB28A Y19
TB28B COM2+
TB28C Empty
TB29A Y1A
TB29B COM2+
TB29C Empty
TB30A Y1B
TB30B COM2+
TB30C Empty
TB31A Y1C
TB31B COM2+
TB31C Empty
TB32A Y1D
TB32B COM2+
TB32C Empty
TB33A Y1E
TB33B COM2+
TB33C Empty
Load
TB34A Y1F 1: Attach an unwired connector plug to an unused one-touch
TB34B COM2+
TB34C Empty connector for power supply and FG.
6 - 47 6 - 47
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
1: Attach an unwired connector plug to an unused one-touch connector for power supply and FG.
Pin layout
6 - 48 6 - 48
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
F
7
supply for output
AJ65VBTCE32-16DT
5mA or lower
E
6
part Current (at 24VDC and all points ON),
D
5
excluding external load current
C
4
Input type Positive common (sink type) Surge suppressor Zener diode
B
3
Supply current for connected
1.0A or lower/common
A
2
device
9
16 points/common
Wiring method for common
8
(input: 3-wire sensor connector (e-CON) type, output: 2-wire sensor connector (e-CON) type)
Y
Number of occupied stations 32-point assignment/station (16 points used)
D
Module power Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
8 9 A B C D E F
0 1 2 3 4 5 6 7
PW L RUNL ERR.
supply Current 40mA or lower (at 24VDC and all points ON)
C
Noise voltage 500Vp-p, noise width 1µs,
Noise immunity
B
noise frequency 25 to 60Hz (DC type noise simulator condition)
ON
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
CON A
10MΩ or higher between all DC external terminals and ground (500VDC insulation resistance
Insulation resistance
tester)
Protection degree IP1XB
Weight 0.11kg
One-touch connector for communication [Transmission circuit]
Communication
5-pin IDC plug is sold separately: A6CON-L5P
part
External <Optional> Online connector for communication: A6CON-LJ5P
connection One-touch connector for power supply and FG [Module power supply, I/O power supply, FG]
system Power supply part 5-pin IDC plug is sold separately: A6CON-PW5P, A6CON-PW5P-SOD
<Optional> Online connector for power supply: A6CON-PWJ5P
I/O part Sensor connector (e-CON) [I/O signals] 4-pin IDC plug is sold separately. 1
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
Connector for Applicable cable:
communication FANC-110SBH, FA-CBL200PSBH, CS-110
2
0.66 to 0.98mm (AWG18)
Connector for
[φ2.2 to 3.0mm (A6CON-PW5P), φ2.0 to 2.3mm (A6CON-PW5P-SOD)]
Applicable power supply and
Wire diameter: 0.16mm or more
wire size FG
Insulating coating material: PVC (heat-resistant)
Sensor connector (e-CON).
Connector for I/O Applicable connector plugs are sold separately. 1
2
(applicable wire size: 0.08 to 0.5mm , depending on the connector plug)
Accessory User’s manual, Holding fixtures for screw installation
6 - 49 6 - 49
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
6 - 50 6 - 50
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
1: Attach an unwired connector plug to an unused one-touch connector for power supply and FG.
Pin layout
6 - 51 6 - 51
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
6 - 52 6 - 52
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
CON A
1 Pin number Signal name
1 DA
LINK CABLE 2
2 DB 1 DA
(IN) 3
3 DG
4 2 DB
4 Empty
5
5 SLD CON A,B 3 DG
CON B
1
1 DA
4 Empty
LINK CABLE 2
(OUT) 2 DB 5 SLD
3
3 DG
4
4 Empty
1 (FG)
5
5 SLD 2 +24V (UNIT)
One-touch connector for communication CON C,D 3 24G (UNIT)
CON C 4 +24V(I/O)
1 Insulation
UNIT POWER CABLE(IN) 1 FG 5 24G(I/O)
2
2 +24V(UNIT)
3
3 24G(UNIT) Pin Signal Pin Signal
4
5
4 +24V(I/O) number name number name
5 24G(I/O)
I/O POWER CABLE(IN) 1 +24V 1 +24V
CON D CON CON
UNIT POWER CABLE(OUT)
1
1 FG 2 +V 2 Empty 1
2 +24V(UNIT)
1 9
2 3 24G 3 24G
3 (X0) (Y8)
3 24G(UNIT)
4
4 +24V(I/O) 4 X0 4 Y8
5
5 24G(I/O) 1 +24V 1 +24V
I/O POWER CABLE(OUT) CON CON
2 2 +V 2 Empty 1
One-touch connector for power supply and FG 2 10
3 24G 3 24G
3 CON1 Constant- (X1) (Y9)
voltage 4 X1 4 Y9
Brown 1 circuit
3-wire sensor 2 1 +24V 1 +24V
(source output) Blue 3 CON CON
Detection 2 +V 2 Empty 1
circuit Black 4 3 11
3 24G 3 24G
(X2) (YA)
4 X2 4 YA
CON8 1 +24V 1 +24V
1 CON CON
2 +V 2 Empty 1
2 4 12
3 3 24G 3 24G
(X3) (YB)
4
4 X3 4 YB
1 +24V 1 +24V
CON CON
2 +V 2 Empty 1
5 13
CON9 3 24G 3 24G
1
(X4) (YC)
4 X4 4 YC
2
3 1 +24V 1 +24V
Load 4 CON CON
2 +V 2 Empty 1
6 14
3 24G 3 24G
1 (X5) (YD)
4 X5 4 YD
CON16 1 +24V 1 +24V
1 CON CON
2 2 +V 2 Empty 1
3
7 15
3 24G 3 24G
Load 4 (X6) (YE)
4 X6 4 YE
1 +24V 1 +24V
CON CON
2 +V 2 Empty 1
8 16
1: Since all No.2 pins of CON9 to CON16 are connected inside the module, they cannot be used. 3 24G 3 24G
(X7) (YF)
2: Attach an unwired connector plug to an unused one-touch connector for power supply and FG. 4 X7 4 YF
3: Wiring the sensor connector (e-CON) incorrectly may cause malfunction or failure due to short circuit of the
power supply.
6 - 53 6 - 53
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
1: Attach an unwired connector plug to an unused one-touch connector for power supply and FG.
Pin layout
6 - 54 6 - 54
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
1F
F
19.2 to 26.4VDC
External Voltage
1E
E
(ripple ratio: within 5%)
power
1D
D
10mA or lower
supply for
1C
C
Current (at 24VDC and all points ON),
output part
1B
B
excluding external load current
1A
A
Input type Positive common (sink type) Surge suppressor Zener diode
19
9
Supply current for connected
AJ65VBTCE32-32DT
1.0A or lower/common
18
8
device
17
7
32 points/common
16
Wiring method for common
6
(input: 3-wire sensor connector (e-CON) type, output: 2-wire sensor connector (e-CON) type)
15
5
Number of occupied stations 32-point assignment/station (32 points used)
14
4
Module power Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
13
3
supply Current 45mA or lower (at 24VDC and all points ON)
12
2
Noise voltage 500Vp-p, noise width 1µs,
11
1
Noise immunity
noise frequency 25 to 60Hz (DC type noise simulator condition)
10
0
X
Y
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
10MΩ or higher between all DC external terminals and ground (500VDC insulation resistance
D
8 9 A B C D E F
0 1 2 3 4 5 6 7
Insulation resistance
tester)
PW L RUN L ERR.
C
Protection degree IP1XB
B
Weight 0.16kg
ON
Communication
5-pin IDC plug is sold separately: A6CON-L5P
part
<Optional> Online connector for communication: A6CON-LJ5P
External One-touch connector for power supply and FG
connection Power supply [Module power supply, I/O power supply, FG]
system part 5-pin IDC plug is sold separately: A6CON-PW5P, A6CON-PW5P-SOD
<Optional> Online connector for power supply: A6CON-PWJ5P
Sensor connector (e-CON) [I/O signals]
I/O part
4-pin IDC plug is sold separately. 1
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
Connector for Applicable cable:
communication FANC-110SBH, FA-CBL200PSBH, CS-110
2
0.66 to 0.98mm (AWG18)
Connector for
[φ2.2 to 3.0mm (A6CON-PW5P), φ2.0 to 2.3mm (A6CON-PW5P-SOD)]
Applicable power supply
Wire diameter: 0.16mm or more
wire size and FG
Insulating coating material: PVC (heat-resistant)
Sensor connector (e-CON).
Connector for
Applicable connector plugs are sold separately. 1
I/O
(applicable wire size: 0.08 to 0.5mm2, depending on the connector plug)
Accessory User’s manual, Holding fixtures for screw installation
6 - 55 6 - 55
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
6 - 56 6 - 56
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
1: Attach an unwired connector plug to an unused one-touch connector for power supply and FG.
Pin layout
6 - 57 6 - 57
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
6 - 58 6 - 58
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
Detection
Blue 3 4 X6 4 Y16
Black 4
circuit 1 +24V 1 +24V
CON8 2 +V CON24 2 Empty 1
(X7) 3 24G (Y17) 3 24G
CON16
1 4 X7 4 Y17
2
1 +24V 1 +24V
3
4 CON9 2 +V CON25 2 Empty 1
(X8) 3 24G (Y18) 3 24G
4 X8 4 Y18
1 +24V 1 +24V
CON17
CON10 2 +V CON26 2 Empty 1
1
2
(X9) 3 24G (Y19) 3 24G
Load
3 4 X9 4 Y19
4
1 +24V 1 +24V
1
CON11 2 +V CON27 2 Empty 1
(XA) 3 24G (Y1A) 3 24G
CON32
4 XA 4 Y1A
1
2 1 +24V 1 +24V
CON12 2 +V
3 CON28 2 Empty 1
Load 4 (XB)
3 24G (Y1B) 3 24G
4 XB 4 Y1B
1 +24V 1 +24V
CON13 2 +V CON29 2 Empty 1
(XC) 3 24G (Y1C) 3 24G
4 XC 4 Y1C
1 +24V 1 +24V
CON14 2 +V CON30 2 Empty 1
(XD) 3 24G (Y1D) 3 24G
4 XD 4 Y1D
1 +24V 1 +24V
CON15 2 +V CON31 2 Empty 1
1: Since all No.2 pins of CON17 to CON32 are connected inside the module, they cannot be used. (XE) 3 24G (Y1E) 3 24G
2: Attach an unwired connector plug to an unused one-touch connector for power supply and FG. 4 XE 4 Y1E
3: Wiring the sensor connector (e-CON) incorrectly may cause malfunction or failure due to short 1 +24V 1 +24V
circuit of the power supply. CON16 2 +V CON32 2 Empty 1
(XF) 3 24G (Y1F) 3 24G
4 XF 4 Y1F
6 - 59 6 - 59
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
1: Attach an unwired connector plug to an unused one-touch connector for power supply and FG.
Pin layout
6 - 60 6 - 60
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
ON
COM-
19.2 to 26.4VDC
CTL+
Voltage
B RATE
40 20 10 8 4 2 1 4 2 1
External (ripple ratio: within 5%)
power supply
+24V
24G
13mA or lower
YF
X7
STATION NO.
for output part Current (at 24VDC and all points ON),
+24V
24G
YE
X6
excluding external load current
+24V
24G
YD
X5
Positive common
Input type Surge suppressor Zener diode
(sink type)
+24V
24G
YC
X4
Supply current for connected device 1.0A or lower/common
+24V
24G
YB
X3
Y8 9 A B C D E F
+24V
24G
YA
A J65SBTC4-16DT
Number of occupied stations 32-point assignment/station (16 points used) X2
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
DA DG +24V
10MΩ or higher between all DC external terminals and ground (500VDC insulation
SLD
Insulation resistance
resistance tester)
DB
6 - 61 6 - 61
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
<Connection example of 4-, 3-, and 2-wire sensors> Terminal number Signal name
TB1 DA
TB2 DB
1 DA
2 DB TB3 DG
3 DG Insulation TB4 SLD
4 SLD
5 +24V TB5 +24V
6 FG TB6 (FG)
7 24G
Module power supply TB7 24G
Pin number Signal name
4-wire sensor 1 X0
CON1
(sink output/ 2 Y8
sink input) Detection
Black 1 CON1
circuit White 2 3 +24V
Brown 3 4 24G
Blue 4
1 X1
The cable colors are selected according to
2 Y9
IEC 60947-5-2 (JIS C 8201-5-2). CON2
3 +24V
4 24G
1 X2
3-wire sensor CON2
(sink output) 2 YA
Black 1 CON3
Detection
2 3 +24V
circuit
Brown 3 4 24G
Blue 4
1 X3
2 YB
CON4
3 +24V
4 24G
1 X4
2 YC
CON5
2-wire sensor CON8 3 +24V
(sink output) Brown 1
Detection
4 24G
2
circuit 3 1 X5
Blue 4 2 YD
CON6
3 +24V
4 24G
1 X6
2 YE
CON7
8 CTL+ 3 +24V
9 COM-
External power supply for output part Constant-voltage circuit 4 24G
1 X7
2 YF
<Connection example of other I/O devices> CON8
3 +24V
4 24G
1 DA
2 DB Terminal number Signal name
3 DG Insulation TB8 CTL+
4 SLD
5 +24V TB9 COM-
6 FG Pin layout
7 24G
Module power supply
CON1
1
2
3
4
CON8
1
Load 2
3
4
8 CTL+
9 COM-
External power supply for output
Constant-voltage circuit
6 - 62 6 - 62
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
ON
13mA or lower
COM-
supply for
CTL+
B RATE
40 20 10 8 4 2 1 4 2 1
Current (at 24VDC and all points ON),
output part
excluding external load current
+24V
24G
YF
X7
STATION NO.
Input type Positive common (sink type) Surge suppressor Zener diode
+24V
24G
YE
X6
Supply current for connected device 1.0A or lower/common
+24V
24G
YD
X5
Wiring method for common 16 points/common (4-wire, one-touch connector type)
24G
+24V
YC
X4
Number of occupied stations 32-point assignment/station (16 points used)
+24V
24G
YB
X3
Y8 9 A B C D E F
Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
Module power supply
A J65SBTC4-16DT2
+24V
24G
YA
X2
Current 40mA or lower (at 24VDC and all points ON)
+24V
24G
Noise voltage 500Vp-p, noise width 1µs,
X1
Y9
Noise immunity
noise frequency 25 to 60Hz (DC type noise simulator condition)
+24V
24G
X0
Y8
X0 1 2 3 4 5 6 7
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground (FG)
24G
10MΩ or higher between all DC external terminals and ground (500VDC insulation
Insulation resistance
DA DG +24V
resistance tester)
SLD
Weight 0.15kg
External 7-point two-piece terminal block [Transmission circuit, module power supply, FG]
Communication part,
connection M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
module power supply part
system Applicable solderless terminal: 2 or less
2-point direct-mount terminal block [I/O power supply]
I/O power supply part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
Applicable solderless terminal: 2 or less
Dedicated one-touch connector [I/O signals]
I/O part
4-pin IDC plug is sold separately.
M4 screw with plain washer finished round (tightening torque range: 0.78 to 1.08N•m)
Module mounting screw
Mountable with a DIN rail in 6 orientations
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
Applicable Communication y RAV1.25-3 (compliant with JIS C 2805)
wire size part, [Applicable wire size: 0.3 to 1.25mm2]
Applicable
module power y V2-MS3, RAP2-3SL, TGV2-3N
solderless
supply part [Applicable wire size: 1.25 to 2.0mm2]
terminal
I/O power
supply part
φ1.0 to 1.4 (A6CON-P214), φ1.4 to 2.0 (A6CON-P220)
[Applicable wire size: 0.14 to 0.2mm2]
I/O part
φ1.0 to 1.4 (A6CON-P514), φ1.4 to 2.0 (A6CON-P520)
[Applicable wire size: 0.3 to 0.5mm2]
Accessory User’s manual
6 - 63 6 - 63
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
<Connection example of 4-, 3-, and 2-wire sensors > Terminal number Signal name
TB1 DA
1 DA TB2 DB
2 DB
3 DG TB3 DG
Insulation
4 SLD
5 +24V
TB4 SLD
6 FG TB5 +24V
7 24G
Module power supply
TB6 (FG)
TB7 24G
4-wire sensor
(sink output/ CON1 Pin number Signal name
sink input) Detection Black 1
White 2
1 X0
circuit
Brown 3 2 Y8
Blue 4 CON1
3 +24V
The cable colors are selected according to
IEC 60947-5-2 (JIS C 8201-5-2). 4 24G
1 X1
2 Y9
3-wire sensor
CON2
CON2
(sink output) 3 +24V
Black 1
Detection
circuit 2 4 24G
Brown 3
Blue 4 1 X2
2 YA
CON3
3 +24V
4 24G
1 X3
2-wire sensor CON8 2 YB
CON4
(sink output) Brown 1 3 +24V
Detection 2
circuit 3 4 24G
Blue 4
1 X4
2 YC
CON5
3 +24V
4 24G
8 CTL+ 1 X5
9 COM-
External power supply for output part Constant-voltage circuit
2 YD
CON6
3 +24V
< Connection example of other I/O devices >
4 24G
1 X6
1 DA
2 DB 2 YE
CON7
3 DG Insulation 3 +24V
4 SLD
5 +24V 4 24G
6 FG
7 24G 1 X7
Module power supply
2 YF
CON8
3 +24V
CON1 4 24G
1
Terminal number Signal name
2
3 TB8 CTL+
4
TB9 COM-
Pin layout
CON8
1
Load 2
3
4
Viewed from the front of the module
8 CTL+
9 COM-
External power supply for output Constant-voltage circuit
6 - 64 6 - 64
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
ON
19.2 to 26.4VDC
COM-
External Voltage
COM+
(ripple ratio: within 5%)
B RATE
40 20 10 8 4 2 1 4 2 1
power
17mA or lower
Y1C
Y1D
Y1E
Y1F
supply for
STATION NO.
Current (at 24VDC and all points ON),
output part
Y1A
Y1B
Y18
Y19
excluding external load current
Positive common
Y14
Y15
Y16
Y17
Input type Surge suppressor Zener diode
(sink type)
Y10-Y1F
X0-XF
Y10
Y11
Y12
Y13
Wiring method for common 32 points/common (1-wire, one-touch connector type)
XC
XD
XE
XF
Y101112 1314 1516 17 Y1819 1A1B1C1D1E1F
Number of occupied stations 32-point assignment/station (32 points used) X8 9 A B C D E F
XA
XB
X8
X9
A J65SBTC1-32DT
Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
Module power supply
Current 50mA or lower (at 24VDC and all points ON)
X4
X5
X6
X7
Noise voltage 500Vp-p, noise width 1µs, X0
X1
X2
Noise immunity X3
X0 1 2 3 4 5 6 7
10MΩ or higher between all DC external terminals and ground (500VDC insulation
DA DG +24V
Insulation resistance
SLD
resistance tester)
Weight 0.16kg
DB
External 7-point two-piece terminal block [Transmission circuit, module power supply, FG]
Communication part,
connection M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
module power supply part
system Applicable solderless terminal: 2 or less
2-point direct-mount terminal block [I/O power supply]
I/O power supply part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
Applicable solderless terminal: 2 or less
I/O part Dedicated one-touch connector [I/O signals] 4-pin IDC plug is sold separately.
Module mounting screw M4 screw with plain washer finished round
(tightening torque range: 0.78 to 1.08N•m)
Mountable with a DIN rail in 6 orientations
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
Applicable Communication y RAV1.25-3 (compliant with JIS C 2805)
wire size part, [Applicable wire size: 0.3 to 1.25mm2]
Applicable
module power y V2-MS3, RAP2-3SL, TGV2-3N
solderless
supply part [Applicable wire size: 1.25 to 2.0mm2]
terminal
I/O power
supply part
I/O part φ1.0 to 1.4 (A6CON-P214), φ1.4 to 2.0 (A6CON-P220)
2
[Applicable wire size: 0.14 to 0.2mm ]
φ1.0 to 1.4 (A6CON-P514), φ1.4 to 2.0 (A6CON-P520)
[Applicable wire size: 0.3 to 0.5mm2]
Accessory User’s manual
6 - 65 6 - 65
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
Terminal Signal
number name
TB1 DA
TB2 DB
TB3 DG
TB4 SLD
TB5 +24V
1 DA TB6 (FG)
2 DB TB7 24G
3 DG Insulation Signal
4 SLD Pin number
5 +24V
name
6 FG 1 X0
7 24G 2 X1
Module power supply CON1
CON1 to CON4 3 X2
1
4 X3
2
3 1 X4
4 2 X5
CON2
3 X6
4 X7
1 X8
2 X9
CON5 to CON8 CON3
Load 3 XA
1
2 4 XB
3 1 XC
Load
4
2 XD
CON4
3 XE
4 XF
1 Y10
2 Y11
CON5
External power 3 Y12
supply for 4 Y13
output part 1 Y14
2 Y15
8 COM+ CON6
9 COM- 3 Y16
Constant-voltage circuit
4 Y17
Load power supply
1 Y18
Load
2 Y19
External power supply for output part CON7
3 Y1A
and load power supply (common)
8 COM+ 4 Y1B
9 COM-
1 Y1C
2 Y1D
CON8
3 Y1E
4 Y1F
Terminal Signal
number name
TB8 COM+
TB9 COM-
Pin layout
6 - 66 6 - 66
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
ON
power
COM-
COM+
17mA or lower
B RATE
supply for
40 20 10 8 4 2 1 4 2 1
Current (at 24VDC and all points ON),
output part
Y1C
Y1D
Y1E
Y1F
excluding external load current
STATION NO.
Y1A
Y1B
Positive common
Y18
Y19
Input type Surge suppressor Zener diode
(sink type)
Y14
Y15
Y16
Y17
Wiring method for common 32 points/common (1-wire, one-touch connector type)
Y10-Y1F
X0-XF
Y10
Y11
Y12
Y13
Number of occupied stations 32-point assignment/station (32 points used)
XC
XD
XE
XF
Y1011 12 1314 1516 17 Y1819 1A1B1C1D1E1F
Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
Module power supply X8 9 A B C D E F
Current 50mA or lower (at 24VDC and all points ON)
A J65SBTC1-32DT1
XA
XB
X8
X9
Noise voltage 500Vp-p, noise width 1µs,
Noise immunity
X4
X5
X6
X7
noise frequency 25 to 60Hz (DC type noise simulator condition) X0
X1
X2
X3
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
X0 1 2 3 4 5 6 7
10MΩ or higher between all DC external terminals and ground (500VDC insulation
Insulation resistance
(FG)
24G
resistance tester)
DA DG +24V
Weight 0.16kg
DB
External 7-point two-piece terminal block [Transmission circuit, module power supply, FG]
Communication part,
connection M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
module power supply part
system Applicable solderless terminal: 2 or less
2-point direct-mount terminal block [I/O power supply]
I/O power supply part M3×5.2 screw (tightening torque range: 0.59 to 0.88N•m)
Applicable solderless terminal: 2 or less
I/O part Dedicated one-touch connector [I/O signals] 4-pin IDC plug is sold separately.
Module mounting screw M4 screw with plain washer finished round
(tightening torque range: 0.78 to 1.08N•m)
Mountable with a DIN rail in 6 orientations
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
Applicable Communication y RAV1.25-3 (compliant with JIS C 2805)
2
wire size part, [Applicable wire size: 0.3 to 1.25mm ]
Applicable
module power y V2-MS3, RAP2-3SL, TGV2-3N
solderless 2
supply part [Applicable wire size: 1.25 to 2.0mm ]
terminal
I/O power
supply part
I/O part φ1.0 to 1.4 (A6CON-P214),
φ1.4 to 2.0 (A6CON-P220)
2
[Applicable wire size: 0.14 to 0.2 mm ]
φ1.0 to 1.4 (A6CON-P514),
φ1.4 to 2.0 (A6CON-P520)
2
[Applicable wire size: 0.3 to 0.5 mm ]
Accessory User’s manual
6 - 67 6 - 67
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
Terminal Signal
number name
TB1 DA
TB2 DB
TB3 DG
TB4 SLD
1 DA
TB5 +24V
2 DB TB6 (FG)
3 DG TB7 24G
Insulation
4 SLD
Signal
5 +24V Pin number
name
6 FG
7 24G 1 X0
Module power supply
CON1 to CON4 2 X1
CON1
1 3 X2
2 4 X3
3
1 X4
4
2 X5
CON2
3 X6
4 X7
1 X8
CON5 to CON8 2 X9
CON3
Load 1 3 XA
2 4 XB
3
Load
1 XC
4
2 XD
CON4
3 XE
4 XF
1 Y10
2 Y11
CON5
3 Y12
External power
supply for 4 Y13
output part 1 Y14
2 Y15
8 COM+ CON6
3 Y16
9 COM-
Constant-voltage circuit 4 Y17
Load power supply 1 Y18
2 Y19
Load
CON7
3 Y1A
External power supply for output part 4 Y1B
8 COM+ and load power supply (common)
1 Y1C
9 COM-
2 Y1D
CON8
3 Y1E
4 Y1F
Terminal Signal
number name
TB8 COM+
TB9 COM-
Pin layout
6 - 68 6 - 68
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
ON
power
COM-
17mA or lower
COM+
supply for
B RATE
40 20 10 8 4 2 1 4 2 1
Current (at 24VDC and all points ON),
output part
Y1C
Y1D
Y1E
Y1F
excluding external load current
STATION NO.
Y1A
Y1B
Positive common
Y18
Y19
Input type Surge suppressor Zener diode
(sink type)
Y14
Y15
Y16
Y17
Wiring method for common 32 points/common (1-wire, one-touch connector type)
Y10-Y1F
X0-XF
Y10
Y11
Y12
Y13
Number of occupied stations 32-point assignment/station (32 points used)
XC
XD
XE
XF
Y1011 12 1314 1516 17 Y18 191A1B1C1D1E1F
Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
X8 9 A B C D E F
Module power supply
Current 50mA or lower (at 24VDC and all points ON)
A J65SBTC1-32DT2
XA
XB
X8
X9
Noise voltage 500Vp-p, noise width 1µs,
Noise immunity
X4
X5
X6
X7
noise frequency 25 to 60Hz (DC type noise simulator condition)
X0
X1
X2
X3
X0 1 2 3 4 5 6 7
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
10MΩ or higher between all DC external terminals and ground (500VDC insulation
(FG)
Insulation resistance
24G
resistance tester)
+24V
Weight 0.16kg
DG
DB
DA
6 - 69 6 - 69
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
Terminal Signal
number name
TB1 DA
TB2 DB
TB3 DG
TB4 SLD
TB5 +24V
1 DA TB6 (FG)
2 DB TB7 24G
3 DG Insulation
4 SLD
Signal
Pin number
5 +24V name
6 FG 1 X0
7 24G
Module power supply 2 X1
CON1 to CON4 CON1
3 X2
1
2 4 X3
3 1 X4
4 2 X5
CON2
3 X6
4 X7
1 X8
CON5 to CON8 2 X9
Load
CON3
1 3 XA
2 4 XB
3
Load
4
1 XC
2 XD
CON4
3 XE
4 XF
1 Y10
2 Y11
External power CON5
3 Y12
supply for output
part 4 Y13
1 Y14
8 COM+ 2 Y15
9 COM- CON6
Constant-voltage circuit 3 Y16
Load power supply 4 Y17
1 Y18
Load
External power supply for output part 2 Y19
CON7
and load power supply (common) 3 Y1A
8 COM+
9 COM- 4 Y1B
1 Y1C
2 Y1D
CON8
3 Y1E
4 Y1F
Terminal Signal
number name
TB8 COM+
TB9 COM-
Pin layout
6 - 70 6 - 70
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
ON
COM-
External
COM+
(ripple ratio: within 5%)
B RATE
40 20 10 8 4 2 1 4 2 1
power
supply for Current 17mA or lower
Y1C
Y1D
Y1E
Y1F
(at 24VDC and all points ON),
STATION NO.
output part
Y1A
Y1B
Y18
Y19
excluding external load current
Positive common
Y14
Y15
Y16
Y17
Input type Surge suppressor Zener diode
(sink type)
Y10-Y1F
X0-XF
Y10
Y11
Y12
Y13
Wiring method for common 32 points/common (1-wire, one-touch connector type)
XC
XD
XE
XF
Y1011 12 13141516 17 Y18191A1B1C1D1E1F
Number of occupied stations 32-point assignment/station (32 points used)
X8 9 A B C D E F
Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
A J65SBTC1-32DT3
XA
XB
X8
X9
Module power supply
Current 50mA or lower (at 24VDC and all points ON)
X4
X5
X6
X7
Noise voltage 500Vp-p, noise width 1µs,
Noise immunity X0
X1
X2
X3
noise frequency 25 to 60Hz (DC type noise simulator condition)
X0 1 2 3 4 5 6 7
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground
(FG)
24G
10MΩ or higher between all DC external terminals and ground (500VDC insulation
Insulation resistance
resistance tester)
+24V
SLD
Weight 0.16kg
DA
6 - 71 6 - 71
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
Terminal
Signal name
number
TB1 DA
TB2 DB
TB3 DG
TB4 SLD
TB5 +24V
1 DA
2 DB TB6 (FG)
3 DG Insulation TB7 24G
4 SLD
Pin number Signal name
5 +24V
6 FG 1 X0
7 24G 2 X1
Module power supply CON1
CON1 to CON4 3 X2
1 4 X3
2
1 X4
3
4 2 X5
CON2
3 X6
4 X7
1 X8
2 X9
CON5 to CON8 CON3
Load 3 XA
1
2 4 XB
3 1 XC
Load
4 2 XD
CON4
3 XE
4 XF
1 Y10
2 Y11
CON5
External power 3 Y12
supply for output 4 Y13
part 1 Y14
2 Y15
8 COM+ CON6
9 COM- 3 Y16
Constant-voltage circuit
4 Y17
Load power supply
1 Y18
2 Y19
Load CON7
3 Y1A
External power supply for output part
4 Y1B
8 COM+ and load power supply (common)
1 Y1C
9 COM-
2 Y1D
CON8
3 Y1E
4 Y1F
Terminal
Signal name
number
TB8 COM+
TB9 COM-
Pin layout
6 - 72 6 - 72
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
ON
OFF→ON
(at 24VDC) time ON→OFF 1.5ms or less (resistive load)
Response time
X8 X9 XA XB XC XD XE XF COM NC Y18 Y19 Y1A Y1B Y1C Y1D Y1E Y1F COM- CTL+
X0 X1 X2 X3 X4 X5 X6 X7 COM NC Y10 Y11 Y12 Y13 Y14 Y15 Y16 Y17 COM- CTL+
B RATE
40 20 10 8 4 2 1 4 2 1
1.5ms or less 10.2 to 26.4VDC
ON→OFF External Voltage
(at 24VDC) (ripple ratio: within 5%)
STATION NO.
power
16 points/common 30mA or lower
supply for
Wiring method for common (1-wire, FCN connector Current (at 24VDC and all points ON),
output part
type) excluding external load current
Y10-Y1F
X0-XF
Positive/negative Wiring method for 16 points/common
Input type common shared type common (1-wire, FCN connector type)
A J65SBTCF1-32DT
Number of occupied stations 32-point assignment/station (32 points used)
Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
Module power supply
Current 50mA or lower (at 24VDC and all points ON)
X0 1 2 3 4 5 6 7
10MΩ or higher between all DC external terminals and ground (500VDC insulation
Insulation resistance
resistance tester)
DB
6 - 73 6 - 73
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
Pin layout Terminal number Signal name
TB1 DA
1 DA TB2 DB
2 DB TB3 DG
3 DG TB4 SLD
Insulation
4 SLD
TB5 +24 V
5 +24V
6 FG TB6 (FG)
7 24G TB7 24G
Module power supply
Pin Signal Pin Signal
B20 X0 number name number name
B19 X1
B20 X0 A20 X8
B18 X2
B17 X3 B19 X1 A19 X9
B16 X4 B18 X2 A18 XA
B15 X5 B17 X3 A17 XB
B14 X6 B16 X4 A16 XC
B13 X7
B15 X5 A15 XD
A20 X8
A19 X9 B14 X6 A14 XE
A18 XA B13 X7 A13 XF
A17 XB B12 COM A12 COM
A16 XC
B11 Empty A11 Empty
A15 XD
XE B10 Y10 A10 Y18
A14
A13 XF B9 Y11 A9 Y19
A,B12 COM B8 Y12 A8 Y1A
A,B11 Empty B7 Y13 A7 Y1B
B10 Y10
Load B6 Y14 A6 Y1C
B9 Y11
B8 Y12 B5 Y15 A5 Y1D
B7 Y13 B4 Y16 A4 Y1E
B6 Y14 B3 Y17 A3 Y1F
B5 Y15
B2 COM- A2 COM-
B4 Y16
B1 CTL+ A1 CTL+
B3 Y17
A10 Y18 Viewed from the
A9 Y19 front of the module
A8 Y1A
A7 Y1B
A6 Y1C
A5 Y1D
A4 Y1E
Load
A3 Y1F
A,B1 CTL+
External power supply
A,B2 COM-
for output part Constant-voltage circuit
Load
A3 Y1F External power supply for output part
A,B1 CTL+ and load power supply (common)
A,B2 COM-
6 - 74 6 - 74
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
6 - 75 6 - 75
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
Pin layout
4
3 DG 4 B18
B17
A18
A17
5
4 Empty 5 B16 A16
5 SLD B15 A15
B14 A14
CON B B13 A13
1 B12 A12
1 DA B11 A11
LINK CABLE 2
2 DB B10 A10
(OUT) 3 B9 A9
3 DG
4 B8 A8
4 Empty B7 A7
5 B6 A6
5 SLD
B5 A5
One-touch connector for communication B4 A4
B3 A3
B2 A2
CON C CON CCON D B1 A1
1 Insulation
UNIT POWER CABLE(IN) 1 FG 1
2
3
2 +24V(UNIT) 2
4
3 24G(UNIT) 3
5
4 Empty 4
5 Empty 5
CON D
1
UNIT POWER CABLE(OUT) 1 FG
2 Viewed from the front
2 +24V(UNIT)
3
4
3 24G(UNIT) of the module
4 Empty
5
5 Empty
6 - 76 6 - 76
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
1:Attach an unwired connector plug to an unused one-touch connector for power supply and FG.
6 - 77 6 - 77
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
6 - 78 6 - 78
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
Pin layout
CON A
1
1 DA CON A CON B CON E
LINK CABLE 2
2 DB 1
(IN) 3 2
3 DG B20 A20
4 3 B19 A19
4 Empty 4 B18 A18
5 5
B17 A17
5 SLD B16 A16
B15 A15
B14 A14
CON B B13 A13
1 B12 A12
1 DA B11 A11
LINK CABLE 2
2 DB
B10
B9
A10
A9
(OUT) 3 B8 A8
3 DG B7
B6
A7
A6
4
4 Empty B5
B4
A5
A4
5 B3 A3
5 SLD CON C CON D B2 A2
B1 A1
One-touch connector for 1
communication 2
3
CON C Insulation 4
1 5
UNIT POWER CABLE(IN) 1 FG
2
2 +24V(UNIT,I/O)
3
3 24G(UNIT,I/O) Viewed from the front of the module
4
4 Empty
5
5 Empty
CON D Pin Pin Signal
1 Signal name
UNIT POWER CABLE(OUT) 1 FG number number name
2
2 +24V(UNIT,I/O)
3 1 DA
3 24G(UNIT,I/O)
4 2 DB
4 Empty
5
Empty
CON
5 3 DG
One-touch connector for A, B
4 Empty
power supply and FG 1
2
CON E 5 SLD
B20, A20 20 X0 20 X8
19 X1 19 X9
18 X2 18 XA
17 X3 17 XB
B13, A13 16 X4 16 XC
15 X5 15 XD
COM- B12, A12 14 X6 14 XE
13 X7 13 XF
12 COM- 12 COM-
Load B10, A10 CON 11 Empty CON 11 Empty
E-B 10 Y10 E-A 10 Y18
9 Y11 9 Y19
8 Y12 8 Y1A
7 Y13 7 Y1B
Load B3, A3 6 Y14 6 Y1C
5 Y15 5 Y1D
4 Y16 4 Y1E
3 Y17 3 Y1F
COM+ B1, A1 2 Empty 2 Empty
1 COM+ 1 COM+
1 (FG)
Constant-voltage circuit +24V
2
(UNIT, I/O)
CON
24G
C-D 3
(UNIT, I/O)
1: Attach an unwired connector plug to an unused one-touch connector for power supply and FG. 4 Empty
2: Do not supply power to the CON E. 5 Empty
6 - 79 6 - 79
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
Online connector
for communication
CON.A
1
1 DA
LINK CABLE 2
(IN) 2 DB
3
3 DG
4
4 Empty
5
5 SLD
CON.B
1
1 DA
LINK CABLE 2
(OUT) 2 DB
3
3 DG
4
4 Empty
5
5 SLD
One-touch connector
for communication
CON.C
1
UNIT POWER CABLE(IN) 1 FG
2
2 +24V(UNIT,I/O)
3 24G(UNIT,I/O)
3
4
4 Empty
5
5 Empty
I/O POWER CABLE(IN) CON.D
1
1 FG
2
UNIT POWER 2 +24V(UNIT,I/O)
CABLE(OUT) 3 24G(UNIT,I/O)
3
4
I/O POWER 4 Empty
5
CABLE(OUT) 5 Empty
1:Attach an unwired connector plug to an unused one-touch connector for power supply and FG.
6 - 80 6 - 80
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
6 - 81 6 - 81
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
Pin layout Connector for communication
Pin
LINK IN LINK OUT
number
1 SLD SLD
2 DB DB
LINK IN 3 DG DG
4
2 4 DA DA
3
1 Communication 5 No pins Empty
circuit Connector for power supply
110
130 Pin
LINK OUT
4 LINK IN UNIT POWER AUX.
number
2
Male
3 Terminating resistor 1 +24V(UNIT) +24V(I/O)
2 1
1 setting switch
5
3 4 2 Empty Empty
3 24G(UNIT) 24G(I/O)
LINK OUT 4 Empty Empty
Insulation 5 FG FG
UNIT POWER Female
1 1 2
3 4 5
3
Connector for I/O
5 Pin Signal Pin Signal
2
4 number name number name
Module mounting screw (FG) UNIT POWER/AUX.
1 +24V 1 +24V
Male
2 1 2 X1 2 Y9
AUX.
1 3
5
4 X0 Y8
X1 3 24G Y9 3 Empty
3
5 4 X0 4 Y8
2 Connector for I/O 5 Empty 5 Empty
4
Constant-voltage circuit Female 1 +24V 1 +24V
Connector for I/O 1 2
5
4-wire sensor
4 3 2 X3 2 YB
X2 YA
(sink output) 3 24G 3 Empty
Black 4 X3 YB
Detection
circuit White 2 4 X2 4 YA
Brown 1
Blue 3 Viewed from the front
5 Empty 5 Empty
5 of the module 1 +24V 1 +24V
3-wire sensor 2 X5 2 YD
(sink output) X4 YC
Black 4 X5 3 24G YD 3 Empty
Detection
2
circuit
Brown 1
4 X4 4 YC
Blue 3 5 Empty 5 Empty
5
1 +24V 1 +24V
2-wire sensor 2 X7 2 YF
(sink output) Brown 4
X6 YE
X7 3 24G YF 3 Empty
Detection 2
circuit 1 4 X6 4 YE
Blue 3
5 Empty 5 Empty
5
Load
4
Load 2
1
3
5
6 - 82 6 - 82
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
protection YE
YF
Protection function
(The LED turns on when any
protection is activated.)
20.4 to 26.4VDC
External Voltage
(ripple ratio: within 5%)
power Y
15mA or lower Y
supply for
Current (at 24VDC and all points ON),
output part
excluding external load current
Y
Input type Negative common (source type) Surge suppressor Zener diode Y
16 points/common Y
6 - 83 6 - 83
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
Pin layout Connector for communication
Pin
LINK IN LINK OUT
number
1 SLD SLD
2 DB DB
3 DG DG
LINK IN 4
2
4 DA DA
3 5 No pins Empty
1 Communication
circuit Connector for power supply
110
Pin
130 UNIT POWER AUX.
LINK OUT 4 number
2 LINK IN 1 +24V(UNIT) +24V(I/O)
3 Terminating resistor Male
1 setting switch 2 Empty Empty
2 1
5 3 4 3 24G(UNIT) 24G(I/O)
4 Empty Empty
Insulation LINK OUT 5 FG FG
UNIT POWER 1 Female Connector for I/O
3 1
5
2
5
4 3 Pin Signal Pin Signal
2 number name number name
4
Module mounting UNIT POWER/AUX. 1 +24V 1 Empty
screw (FG)
Male 2 X1 2 Y9
2 1 X0 Y8
AUX. 1 3
5
4 X1 3 24G Y9 3 24G
3 4 X0 4 Y8
5
2 Connector for I/O 5 Empty 5 Empty
4 1 +24V 1 Empty
Female
1 2
Connector for I/O
Constant-
4 5
3 2 X3 2 YB
4-wire sensor voltage circuit X2 YA
X3 3 24G YB 3 24G
(souce output)
4
Detection
Black
4 X2 4 YA
circuit White 2
Brown 1 Viewed from the front 5 Empty 5 Empty
Blue 3 of the module
5 1 +24V 1 Empty
2 X5 2 YD
3-wire sensor X4 YC
(souce output) X5 3 24G YD 3 24G
Black 4
Detection
2 4 X4 4 YC
circuit
Brown 1 5 Empty 5 Empty
Blue 3
5 1 +24V 1 Empty
2 X7 2 YF
2-wire sensor X6 YE
(souce output) 4 X7 3 24G YF 3 24G
Brown
Detection
2 4 X6 4 YE
circuit Blue 1
3 5 Empty 5 Empty
5
Load 4
Load 2
1
3
5
6 - 84 6 - 84
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
AJ65SBTW4-16DT
time
L ERR.
ON→OFF 1.5ms or less (resistive load)
L RUN
YC
YD
YA
YB
YE
YF
Y8
Y9
STATION NO.
20.4 to 26.4VDC
External Voltage
(ripple ratio: within 5%)
PW
X0
X1
X2
X3
X4
X5
X6
X7
power
MITSUBISHI
13mA or lower
supply for
Current (at 24VDC and all points ON),
output part
CON7
CON8
excluding external load current
Input type Positive common (sink type) Surge suppressor Zener diode
16 points/common (4-wire, waterproof connector type)
Wiring method for common
Same as that for the module power supply
CON5
CON6
Number of occupied stations 32-point assignment/station (16 points used)
Voltage 20.4 to 26.4VDC (ripple ratio: within 5%)
Module power supply
Current 50mA or lower (at 24VDC and all points ON)
CON3
CON4
Noise voltage 500Vp-p, noise width 1µs,
Noise immunity
noise frequency 25 to 60Hz (DC type noise simulator condition)
Withstand voltage 500VAC for 1 minute between all DC external terminals and ground CON1
CON2
10MΩ or higher between all DC external terminals and ground (500VDC insulation
Insulation resistance
resistance tester)
POWER CABL
POWER CABL
7-point two-piece terminal block [Transmission circuit, module power supply, FG]
LINK CABL
LINK CABL
6 - 85 6 - 85
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
Terminal Signal
<Connection example of 4-, 3-, and 2-wire sensors>
number name
TB1 DA
TB2 DB
LINK CABLE TB3 DG
1 DA TB4 SLD
2 DB
TB5 +24V
3 DG
Insulation TB6 (FG)
4 SLD
5 +24V TB7 24G
6 FG
Pin Signal
7 24G
Constant- number name
Module power supply and POWER CABLE voltage circuit
external power supply (common) 1 +24V
2 Y8
CON1
Module 3 24G
mounting 4 X0
screw
1 +24V
4-wire sensor 2 Y9
(sink output/ CON1 CON2
Black 4 3 24G
sink input) Detection
circuit White 2
4 X1
Brown 1
Blue 3 1 +24V
2 YA
CON3
3 24G
4 X2
1 +24V
2 YB
3-wire sensor CON2 CON4
3 24G
(sink output) Black 4
Detection 4 X3
circuit 2
Brown 1 1 +24V
Blue 3 2 YC
CON5
3 24G
4 X4
1 +24V
2 YD
CON6
3 24G
4 X5
2-wire sensor CON8
1 +24V
(sink output) Brown 4
Detection 2 2 YE
circuit CON7
1 3 24G
Blue 3
4 X6
1 +24V
2 YF
CON8
3 24G
4 X7
6 - 86 6 - 86
6 SPECIFICATIONS FOR COMBINED MODULES
MELSEC-A
External connection
LINK CABLE
1 DA
2 DB
3 DG Insulation
4 SLD
5 +24V
6 FG
7 24G Constant-
Module power supply and POWER CABLE voltage circuit
external power supply (common)
Module
mounting
screw
CON1
4
2
1
3
CON8
4
Load 2
1
3
Pin layout
6 - 87 6 - 87
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
• Prevent foreign matter such as dust or wire chips from entering the module.
CAUTION Such foreign matter can cause a fire, failure, or malfunction.
• Do not disassemble or modify the module.
Doing so may cause failure, malfunction, injury, or a fire.
• Do not directly touch any conductive part of the module.
Doing so can cause malfunction or failure of the module.
• Do not drop or apply any strong shock to the module. Doing so may damage the
module.
• Use applicable solderless terminals and tighten them within the specified torque
range. If any spade solderless terminal is used, it may be disconnected when the
terminal screw comes loose, resulting in failure.
• Tighten the terminal screw within the specified torque range.
Undertightening can cause fire or malfunction.
Overtightening can damage the screw, resulting in short circuit or malfunction.
• When disposing of this product, treat it as industrial waste.
• Use the module in an environment that meets the general specifications in this
manual.
Failure to do so may result in electric shock, fire, malfunction, or damage to or
deterioration of the product.
• Securely fix the module with a DIN rail or mounting screws. Tighten the screws
within the specified torque range.
Undertightening can cause drop of the screw, short circuit or malfunction.
7 Overtightening can damage the screw, resulting in drop or short circuit.
• Shut off the external power supply (all phases) used in the system before mounting
or removing a module to/from a control panel.
Failure to do so may cause the module to fail or malfunction.
(1) Tighten the module mounting screw or terminal block screw within the following
torque range. Overtightening can damage the module case.
(a) Terminal block type, one-touch connector type, or FCN connector type
Screw Tightening torque range
Module mounting screw (M4 screw with plain washer finished round) 0.78 to 1.08N·m
Terminal block screw (M3) 0.59 to 0.88N·m
Terminal block installation screw (M3.5) 0.68 to 0.98N·m
7-1 7-1
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
(d) Spring clamp terminal block type or sensor connector (e-CON) type
Screw Tightening torque range
Mounting bracket (M4) 0.82 to 1.11N·m
POINT
• For a terminal and a screw, avoid adhering to oil.
Doing so may damage the screw.
• When using two solderless terminals, place them with their backs faced.
If not, a screw cannot be full inserted, resulting in damage to the screw.
• Tighten the terminal screw with an applicable driver.
Failure to do so may damage the screw.
7-2 7-2
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
(3) Observe the following points when installing a module to a control panel using a
DIN rail.
(a) Applicable DIN rail (compliant with IEC 60715)
TH35-7.5Fe
TH35-7.5Al
(b) Mounting pitch
When installing a DIN rail to a control panel, keep mounting pitches 200mm
(7.87 inches) or less.
(c) Area where screws cannot used for Din rail installation
When installing the AJ65VBTCE -16 and AJ65VBTCE -32 to the DIN
rail horizontally as shown below, tighten a screw so that a certain distance will
be ensured between the screw and the DIN rail hook on the right side of
module.
Failure to do so may cause the screw to interfere with the DIN rail hook.
1) For AJ65VBTCE -16
Tighten a screw keeping a distance of 50mm (1.97 inches) or more from
the DIN rail hook on the right side of module.
DIN rail hook
3M 35610 B
3M 35610 A
7-3 7-3
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
3M 35610 B
3M 35610 A
1
80mm (3.15 inches)
1
(4) When mounting the compact remote I/O module to a DIN rail, push in the DIN rail
hook located at the bottom of the module until it clicks.
For AJ65SBTB1-8 , AJ65SBTB1-16 , For AJ65SBTB1B-16 , AJ65SBTB1-32 ,
AJ65SBTC4-16 , AJ65SBTC1-32 , AJ65SBTB2-16 , AJ65SBTB2N-16 ,
AJ65SBTCF1-32 , AJ65SBTB2-8 , AJ65SBTB3-16 , AJ65SBTB32-16 ,
AJ65SBTB2N-8 , AJ65SBTB32-8 , AJ65VBTS -32 , AJ65VBTCE -32
AJ65VBTS -16 , AJ65VBTCE -8 , compact remote I/O modules
AJ65VBTCE -16
compact remote I/O modules
DIN rail
DIN rail DIN rail hook
DIN rail hook
Board
DIN rail
7-4 7-4
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
(5) When mounting the compact remote I/O module on the DIN rail, put its upper
hook onto the fixing bracket and push the module until it clicks.
Click
[Mounting dimensions]
(a) A6PLT-J65V1 (For module width 41mm only) (b) A6PLT-J65V2 (For module width 60mm only)
M4 screw 8mm M4 screw 8mm
long or more long or more
6 29 7.5 45
35
35
17.5
17.5
41 60 7.5
Unit : mm
(6) Do not install the compact remote I/O module to the place where:
(a) an ambient temperature is outside the range of 0 to 55°C (0 to 45°C for the
waterproof remote I/O module),
(b) ambient humidity is outside the range of 10 to 99%RH,
(c) condensation occurs due to a sudden temperature change,
(d) corrosive gas or combustible gas is present,
(e) conductive powder (such as dust and iron powder), oil mist, salinity, or
organic solvent is filled,
(f) the module is exposed to direct sunlight,
(g) a strong electric field or strong magnetic field is generated, and
(h) the module is subject to vibration or shock.
7-5 7-5
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
(7) When installing the compact remote I/O module into a panel, etc., provide 60mm
(2.36 inches) or more of space between the top and bottom of the module and
other structures or parts so that good ventilation and ease of operation when
exchanging modules can be secured.
(9) When installing the waterproof-type remote I/O module, provide the space shown
in the figure below between the top and bottom of the module and other structures
or parts so that good ventilation can be secured and that interference and
application of load on the waterproof connector can be prevented.
When connecting two modules in parallel, secure 5mm (0.2 inches) of space
between them.
5 (0.20) or more
3 (0.12) or more
Installation
surface
80 (3.15) or more 1
7 (0.28) or more
Unit : mm (inch)
7-6 7-6
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
(10) If a waterproof cap is being installed on the low profile waterproof type remote I/O
module, in order to improve ventilation and also to prevent interference, as well
as to prevent a load from bearing on the waterproof connector, all the distances
shown in the following figures between the module's side surfaces and the
structure or parts.
1 2
0 or more 0 or more
1 2
0
or more
1
0 or more
2
2 or more
1 If you disconnect and connect the communications adapter, set the operating
distance using a screwdriver, etc.
2 If you are using a right angle type waterproof plug or Y branch connector, set a
distance where no load will be brought to bear on the cable.
7-7 7-7
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
(11) When installing the sensor connector (e-CON) type modules in parallel, take
intervals between the modules as shown below.
(The interval is required for the size of a DIN rail hook or mounting brackets.)
*3
Installation method of the module Installation orientation of the module Interval
Basic, Upside down
5mm
*1 (vertical installation)
Using a DIN rail
Basic, Upside down
5mm
(horizontal installation)
Basic, Upside down
5mm
*2 (vertical installation)
Using screws
Basic, Upside down
15mm
(horizontal installation)
* 1 This is the case when a DIN rail is installed horizontally. Do not apply this interval
to the AJ65VBTCE -8 .
* 2 This is the case when mounting brackets are attached on the top and bottom
sides of the module. If the brackets are attached on the right and left sides of the
module, apply the intervals reversely. (The interval for the vertical installation is
15mm and the interval for the horizontal installation is 5mm.)
* 3 The interval indicates the distance from the modules that are installed on the
either side.
Switch lever
Driver
7-8 7-8
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
The following table lists one-touch connector plugs applicable to the CC-Link system
compact remote I/O module.
Specifications
Mitsubishi model Part model name Applicable Maximum Color of the
Product name
name (manufacturer) Applicable cable size (core) cable size rated cover
(diameter) current
One-touch 33104-6000FL φ1.0 to
A6CON-P214 2 Transparent
connector plug 5 0.14 to 0.2mm 1.4mm
2A
1, 4 33104-6100FL (AWG26 to 24) φ1.4 to
A6CON-P220 Yellow
5 2.0mm
33104-6200FL φ1.0 to
A6CON-P514 2 Red
5 0.3 to 0.5mm 1.4mm
3A
33104-6300FL (AWG22 to 20) φ1.4 to
A6CON-P520 Blue
5 2.0mm
2
One-touch communication 0.5mm φ2.2 to
connector plug line (AWG20) 3.0mm
35505-6000-
for A6CON-L5P 2
Red
B0M GF 5 0.5mm
communication shielded cable
(AWG20)
2, 4
One-touch 2
0.75mm (0.66 to 0.98mm )
2
35505-6080-A00 φ2.2 to
connector plug A6CON-PW5P (AWG18) wire diameter Gray
GF 5 3.0mm
for power 0.16mm or more
supply and FG 7A
Outer insulation layer
2, 4, 6 A6CON-PW5P- 35505-6180-A00 material PVC φ2.0 to
Blue
SOD GF 5 (Heat-resistant vinyl) 2.3mm
Online
connector for 35720-L200-B00
A6CON-LJ5P — — — — —
communication AK 5
3
Online
connector for 35720-L200-A00
A6CON-PWJ5P — — — — —
power supply AK 5
and FG 3
7-9 7-9
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
7.2.2 Precautions for transition wiring of one-touch connector for power supply and FG
Current flows in the modules when they are transition wired through one-touch
connectors for power supply and FG. Design the system so that the current flows in
each module equals to or lower than the maximum rated current shown below.
Input module Output module
(Example:AJ65VBTCE32-16DT) (Example:AJ65VBTCE2-16T)
CONA CONA
1 1
1 DA 1 DA
LINK CABLE LINK CABLE 2
2 2 DB
2 DB (IN) 3
(IN) 3 3 DG
3 DG 4
4 4 Empty
4 Empty 5
5 5 SLD
5 SLD
CONB CONB
1 1
1 DA 1 DA
LINK CABLE LINK CABLE 2
2 2 DB
2 DB (OUT) 3
(OUT) 3 3 DG
3 DG 4
4 4 Empty
4 Empty
One-touch connector 5 One-touch connector
5 5 SLD
5 SLD power supply and FG One-touch connector power supply and FG
One-touch connector for communication
for communication
CONC
CONC
3) UNIT POWER CABLE(IN)
1
1 FG
Insulation
1 Insulation 2
UNIT POWER CABLE(IN) 1 FG 2 +24V(UNIT)
2 3
1) 3
2
3
+24V(UNIT) 4
3
4
24G(UNIT)
+24V(I/O)
24G(UNIT) 5
4
2) 5
4
5
+24V(I/O)
I/O POWER CABLE(IN)
5 24G(I/O)
24G(I/O) COND
I/O POWER CABLE(IN) 1
COND UNIT POWER CABLE(OUT) 1 FG
8) UNIT POWER CABLE(OUT)
1
1 FG
2
3
2 +24V(UNIT)
2 3 24G(UNIT)
2 +24V(UNIT) 4
3 4 +24V(I/O)
3 24G(UNIT) 5
4 5 24G(I/O)
4 +24V(I/O) Connector for input signals
5 I/O POWER CABLE(OUT)
5 24G(I/O) (e-CON) Connector for output signals
I/O POWER CABLE(OUT) One-touch connector for
9) One-touch connector 7) power supply and FG
CON1 (e-CON)
for power supply and FG 1
CON1 Constant-
4) Brown 1
voltage circuit
2
3
Constant-
voltage circuit
3-wire type
2 Load 4
sensor
(sink output) Blue 3
Detection
circuit Black 4
5) 2 1
CON8
1 CON16
2 1
3 2
4 3
Load 4
6) CON9
1
2
3
Load 4
2 1
CON16
1
2
3
Load 4
Maximum rated
No. Power port Connector
current
1
1) Module power supply (IN) One-touch connector for power supply and FG (No.2 and 3 pins of CONC) 7A
1
2) I/O power supply (IN) One-touch connector for power supply and FG (No.4 and 5 pins of CONC) 7A
Maximum current
No. Power supply Power port (source) Description
consumption
3) Module power supply Module power supply (IN) Power supply for CC-Link modules Module power supply
4) Power supply for input Power supply for input devices connected, Supply current for
device such as sensors connected device
5) Input current Input signals from input devices Rated input current
6) External load power I/O power supply (IN) Power supply that is consumed by the load
Maximum load current
supply
7) External power supply Power supply for output circuits External power supply for
for output part output part current
8) Module power supply Power supply for the modules and external
Module power supply (IN) Depends on the modules
(OUT) devices connected by transition wiring
and external devices
9) I/O power supply (OUT) Power supply for the modules and external
I/O power supply (IN) connected
devices connected by transition wiring
1 The value of 1) equals to the sum of 3) and 8). The value of 2) equals to the sum of 4), 5), 6), 7), and 9). Design the system so that
each value of 1) and 2) equals to or lower than the maximum rated current (7A).
7 - 10 7 - 10
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
This section describes the wiring procedures for the one-touch connector of the one-
touch connector type or connector type compact remote I/O module.
Plug cover
Plug body
1) Check the connector.
Check that a plug cover is attached to the plug.
Note: Do not press the plug cover firmly into the plug before a
cable is inserted.
Metal contact Once crimped, the plug can no longer be used.
2) Insert a cable. ( 1)
ss Lift the end of the plug cover and insert a cable until it reaches
r le
mo
1m the other end of the cover (within 1mm from the other end).
Failure to do so may cause an improper crimping.
Note: When inserting the cable, prevent the cable from sticking
out from the plug cover end.
Metal contacts
Metal contacts
7 - 11 7 - 11
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
[Correct example] 6) Check that the plug cover is horizontally-embedded to the plug.
Check also that the cover is not floating.
Latches
Latch
Clearance
(Wiring completed)
7 - 12 7 - 12
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
This section describes the wiring procedures for the one-touch connector for
communication used for the connector type compact I/O module.
Note: Do not press the plug cover firmly into the plug before a
cable is inserted.
Metal contact Once crimped, the plug can no longer be used.
3) Insert a cable.
Lift the end of the plug cover and insert a cable until it reaches
the other end of the cover (within 1mm from the other end).
Failure to do so may cause an improper crimping.
Metal contacts
Metal contacts
7 - 13 7 - 13
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
Latches
Latch
Clearance
(Wiring completed)
7 - 14 7 - 14
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
7.2.5 Wiring procedures for the one-touch connector for power supply and FG
This section describes the wiring procedures for the one-touch connector used for
power supply and FG of the connector type compact I/O module.
Plug cover
Plug body 1) Check the connector.
Check that a plug cover is attached to the plug.
Note: Do not press the plug cover firmly into the plug before a
cable is inserted.
Metal contact
Once crimped, the plug can no longer be used.
2) Insert a cable. ( 1)
Lift the end of the plug cover and insert a cable until it reaches
the other end of the cover (within 1mm from the other end).
Failure to do so may cause an improper crimping.
Metal contacts
Note: Use cables applicable to the module.
7 - 15 7 - 15
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
0.2mm or less
Note: As shown in the wrong example on the left, if the cover is
not horizontally-embedded or the floating part is 0.2mm
or more, it may result in improper crimping.
[Wrong example] Press the plug cover firmly into the plug with pliers. (Refer
to the correct example.)
Latches
Latch
Clearance
(Wiring completed)
7 - 16 7 - 16
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
The following table lists the model names of dustproof cap and waterproof cap
applicable to the CC-Link system waterproof-type remote I/O module.
Mitsubishi model name Specifications
1
Dustproof cap A6CAP-DC1 —
1
Waterproof cap A6CAP-WP1 Protection of degree IP67
The attachment procedure for the waterproof plug supplied with the AJ65SBTW4-16
is shown below. In order to prevent water leakage, attach a waterproof plug to the
penetrating pipe for the transmission and module power-supply lines in the following
way.
1) Remove the nut and bushing from the penetrating pipe attached to the
module.
2) Insert the waterproof plug into the penetrating pipe and secure it by tightening
the nut.
Tightening torque: 0.99 to 1.48N·m
Waterproof pulg
7 - 17 7 - 17
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
This section describes the wiring procedure of a terminal block to the waterproof-type
remote I/O module.
1) Remove the module front cover, and pass the cables through the through
pipe for the transmission and module power-supply lines.
2) Open the module top cover and remove the terminal block, then perform
wiring to the terminal block.
DA DG +24V 24G
CC-Link
DB SLD FG
cable
Power
cable
3) Secure the terminal block using screws, then fasten the module front and top
covers using screws.
4) Tighten the nut on the through pipe for the transmission and module power-
supply lines.
POINT
• Always install a waterproof plug to the unused through pipe for the transmission
and module power-supply lines. (Refer to Section 7.3.2.)
• When wiring the transmission and module power-supply lines, please take care
not to apply force in excess of 0.39N·m excessive force to the wiring at the inlet.
• In the event of the ambient temperature exceeding 56 °C after wiring the unit,
make sure to re-tighten the nuts.
7 - 18 7 - 18
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
7.4 Handling of the Low Profile Waterproof Type Remote I/O Module
The model name of the waterproof cap applicable to the CC-Link system low profile
waterproof type remote I/O module (AJ65FBTA -16 ) is shown below. The following
table lists the model names of waterproof cap applicable to the CC-Link system low
profile waterproof type remote I/O module (AJ65FBTA -16 ).
Mitsubishi Product
Use
Model Name
Waterproof cap
A6CAP-WP2 For LINK OUT connector and I/O connector
(20 pieces, Sold separately)
POINT
• The waterproof cap (A6CAP-WP1) cannot be used.
The installation method for the waterproof caps packed with the product is shown
below.
In order to prevent water penetration, install the waterproof caps on the unused Link
Out side connectors and I/O connectors using the following method.
1) Insert the waterproof cap in the empty connector on the main module, then
tighten it.
Tightening Torque Range: 0.29 to 0.34N·m
7 - 19 7 - 19
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
7.5 Connectors and Tools Used for Connecting the FCN Connector Cables
Three types of 40-pin connectors are available for the AJ65 BTCF1-32 and the
AJ65 BTCF1J-32 ; they are soldering type, pressure-displacement type and crimp-
contact type.
Please purchase the required 40-pin connector, and either pressure-displacement or
crimp-contact type tool according to the listing below.
7 - 20 7 - 20
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
7.6 Attaching and Removing the Protective Cover for the Compact Remote I/O Module
Covering the front of CC-Link system compact remote I/O module with a protective
cover can prevent the following accidents:
• Improper contact to the terminal block or connector.
• Module malfunction resulted from connector drop.
For the model name of the protective cover for the compact remote I/O module, see
Section 1.5.
Follow the procedure illustrated below to mount the protective cover on the module.
Click
<How to remove>
Place your thumb under the protective cover and pull it upwards.
7 - 21 7 - 21
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
CON A,B,C,D
Model No. of
protective cover
: Attach the protective cover, keeping its model No. and the CON A, B, C and D
in the same orientation.
Otherwise, the cover cannot be attached.
Securely fix tabs of the protective cover to the groove of the module as shown
below.
Note that the fixing tab positions vary with the protective cover used.
Tab
Tab
Tab Tab
7 - 22 7 - 22
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
<How to remove>
Extend the width of protective cover slightly as shown by the arrow 1). Then, pull
it out vertically from the module as shown by the arrow 2).
1)
1)
2)
POINT
(1) When attaching the protective cover, ensure the space of 50mm or more between the target
module and the modules on the right and left sides. Also, ensure the space of 100mm or more
over the upper part of the module, so that the cover can be pulled upward.
Structure, other device, parts, etc. Structure, other device, parts, etc.
1 2 4 1 2 4 8 102040
B RATE STATI ON NO.
ON
B
0 1 2 3 4 5 6 7
C
DY
X
8
0
9
1
A
2
B
AJ65VBTCE32- 16DT
C
4
D
100mm or more
>PC<
6
E
7
F
(2) Fix the wiring with a clamp or similar parts. Failure to do so may apply force to the protective
cover, resulting in it falling from the module. In addition, the wiring cable may be damaged.
(3) When mounting both of the Terminal resistor attached one-touch connector plug (A6CON-
TR11) and Online connector for communication (A6CON-LJ5P), make sure to follow the
procedure provided below.
Failure to do so may cause the terminating resistor, protective cover and communication cable
to interfere with each other.
• Tilt the terminating resistor toward 1) or 2) as shown in the diagram below, and then attach
the protective cover.
• Connect the Terminal resistor attached one-touch connector plug to CON B.
1) 2) Terminating resistor
Communication cable
7 - 23 7 - 23
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
This section describes how to connect the compact remote I/O module to the master
module using CC-Link dedicated cables.
• Shut off the external power supply (all phases) used in the system before wiring.
WARNING
Failure to do so may result in electric shock or damage to the product.
• After wiring, attach the included terminal cover to the module before turning it on for
operation.
Failure to do so may result in electric shock.
• Shut off the external power supply (all phases) used in the system before cleaning
the module or retightening the terminal block screw. Failure to do so may cause the
module to fail or malfunction.
• Do not install the control lines or communication cables together with the main
CAUTION
circuit lines or power cables.
Keep a distance of 100mm (3.9 inches) or more between them.
Failure to do so may result in malfunction due to noise.
• Ground the FG terminal to the protective ground conductor dedicated to the
programmable controller.
Failure to do so may result in electric shock or malfunction.
• Tighten any unused terminal screws within the specified torque range (0.42 to
0.50N•m).
Failure to do so may cause a short circuit due to contact with a solderless terminal.
• Use applicable solderless terminals and tighten them within the specified torque
range. If any solderless spade terminal is used, it may be disconnected when the
terminal screw comes loose, resulting in failure.
• Check the rated voltage and terminal layout before wiring to the module, and
connect the cables correctly.
Connecting a power supply with a different voltage rating or incorrect wiring may
cause a fire or failure.
• Securely connect the cable connectors.
Poor contact may cause malfunction.
• Place the cables in a duct or clamp them.
If not, dangling cable may swing or inadvertently be pulled, resulting in damage to
the module or cables or malfunction due to poor contact.
• Do not install the control lines or communication cables together with the main
circuit lines or power cables.
Failure to do so may result in malfunction due to noise.
• When disconnecting the cable from the module, do not pull the cable by the cable
part.
For the cable with connector, hold the connector part of the cable.
For the cable without connector, loosen the screw first and remove it.
Pulling the cable connected to the module may result in malfunction or damage to
the module or cable.
7 - 24 7 - 24
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
(1) The following figure shows how to connect compact remote I/O modules to a
master module.
Terminating Master module
resistor
NC
(Blue) DA
NC
(White) DB
NC
(Yellow) DG
Compact remote I/O module 1 Compact remote I/O module 2
NC
SLD DA DG +24V 24G DA DG +24V 24G
NC
FG DB SLD FG DB SLD FG
Terminating
resistor 1
[Simplified diagram]
Compact remote Compact remote
Master module I/O module 1 I/O module 2
(Blue) (Blue) (Blue) (Blue)
DA DA DA
(White) (White) (White) (White)
DB DB DB
Terminating (Yellow) (Yellow) (Yellow) (Yellow)
Terminating
resistor DG DG DG resistor
SLD CC-Link SLD CC-Link SLD
dedicated cable dedicated cable
FG FG FG
1 Connect a terminating resistor as shown below to the compact remote I/O module
connected as the last station. (Terminating resistors are provided with a master
module.)
DA DG +24V 24G
DB SLD FG
Terminating resistor
POINT
Compact remote I/O modules with an input response of 0.2ms are more susceptible
to noise interference than other modules. Keep the wiring of the I/O module away
from power cables as much as possible.
7 - 25 7 - 25
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
(2) The following figure shows how to connect connector type remote I/O modules to a
master module.
Master module
Terminating CONA CONA
1 1
resistor *1 NC 2
1 DA
2
1 DA
2 DB 2 DB
(Blue) DA 3 3 DG 3 3 DG
NC 4 4 NC 4 4 NC
5 5
(White) DB 5 SLD 5 SLD
NC CONB CONB
(Yellow) DG 1 1 DA 1 1 DA
NC 2 2 DB 2 2 DB
3 3 DG 3 3 DG
SLD 4 4
4 NC 4 NC
NC 5 5
5 SLD Terminating 5 SLD
FG
resistor *1
Ver.1.10-compatible
CC-Link dedicated cable*2
[Simplified diagram]
Connector type remote Connector type remote
Master module I/O module 1 I/O module 2
(Blue) (Blue) (Blue) (Blue)
DA DA DA
(White) (White) (White) (White)
DB DB DB
Terminating (Yellow) (Yellow) (Yellow) (Yellow) Terminating
resistor DG DG DG resistor
SLD SLD SLD
Ver.1.10-compatible Ver.1.10-compatible
FG CC-Link dedicated cable FG CC-Link dedicated cable FG
1 Connect the following type of terminating resistor when a connector type remote
I/O module is connected as the last station.
5 4 3 2 1
54 32 1
A6CON-TR11
POINT
Compact remote I/O modules with an input response of 0.2ms are more susceptible
to noise interference than other modules. Keep the wiring of the I/O module away
from power cables as much as possible.
7 - 26 7 - 26
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
(3) The following figure shows how to connect a one-touch connector and online
connector to the remote I/O module.
Connector plug
(A6CON-L5P)
POINT
• For a one-touch connector for communication, use Ver.1.10-compatible CC-Link
dedicated cables (FANC-110SBH, FA-CBL200PSBH, or CS-110).
Ver.1.10-compatible CC-Link dedicated cables other than those above, CC-Link
dedicated cables, and CC-Link dedicated high-performance cables are not
supported.
• To connect or remove a one-touch connector to/from an online connector, refer to
the manual included with the online connector.
7 - 27 7 - 27
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
7.8 Handling of Spring Clamp Terminal Block Type Remote I/O Module
1) Push the spring clamp terminal block fixing tabs of the 2-piece terminal block
in the arrow direction until a click can be heard.
2) Connect the connector (female) of the 2-piece terminal block to the connector
(male) of the module body and press it until a click can be heard. Check that
both of two fixing tabs are inserted completely.
Connector
Module body
3) Tighten the 2-piece terminal block fixing screws. (Tightening torque range:
0.34 to 0.46N·m)
2-piece terminal
block fixing screws
Screwdriver
C
D
7 - 28 7 - 28
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
This section describes the procedure for connecting a cable to the spring clamp
terminal block remote I/O module.
Wire
Tool
7 - 29 7 - 29
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
1 Use this product when doing the terminal treatment of the wire and inserting it into
the spring clamp terminal block.
7 - 30 7 - 30
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
This section describes the procedures for directly installing the AJ65VBTS - or
AJ65VBTCE - to a control panel using mounting brackets and screws. If the
module is not fixed securely, it can cause drop of the module, short circuit, or
malfunction.
(1) Align the projections of a mounting bracket with the corresponding slots of the
module.
(2) Obliquely insert the projections to the slots, and press down the mounting bracket
in the direction of an arrow until it clicks.
(3) Screw the mounting bracket to a control panel. (Tightening torque range: 0.82 to
1.11N·m)
C
D
Control panel
7 - 31 7 - 31
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
(1) AJ65VBTS -16 The mounting brackets can be attached as shown below
(two different ways).
ON ON
PW L RUN L ERR. PW L RUN L ERR.
B RATE STATION NO.
1 2 4 1 2 4 8 1020 40
AJ65VBTS2-16T AJ65VBTS2-16T
0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7
8 9 A B C D E F 8 9 A B C D E F
NC Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 YA YB YC YD YE YF NC Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 YA YB YC YD YE YF
COM- NC COM- NC
CON A B C D CON A B C D
(2) AJ65VBTS -32 The mounting brackets can be attached as shown below
(only one way).
ON
PW L RUN
L ERR.
B RATESTATION NO.
1 2 4 1 2 4 8 102040
AJ65VBTS3-32D
0 1 2 3 4 5 6 7
8 9 A B CD E F
NC X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF NC X10 X11 X12 X13 X14 X15 X16 X17 X18 X19 X1A X1B X1C X1D X1E X1F
CON A B C D
CON ON CON ON
1 1
2 2
A 3 A 3
4 4
5 5
6 6
7 7
8 8
9 9
B 10 B 10
40 S 40 S
T T
20 A 20 A
10 T
C 10 T
C I I
8 O 8 O
4 N 4 N
2 N 2 N
1 O. 1 O.
D 4 B D 4 B
R R
2 A 2 A
T T
1 E 1 E
AJ65VBTCE3-8D A J65VBTCE3-8D
PW PW
X0 L RUN
X0 L RUN
L ERR. L ERR.
X1 X1
0 0
1 1
X2 2
X2 2
3 3
X3 4 X3 4
5 5
6 6
X4 7 X4 7
X5 X5
X6 X6
X7 X7
7 - 32 7 - 32
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
ON ON
PW L RUNL ERR. AJ65VBTCE3-16D PW L RUNL ERR. AJ65VBTCE3-16D
1 2 4 1 2 4 8 102040
1 2 4 1 2 4 8 102040
B RATE STATION NO.
8 9 A B C D E F 8 9 A B C D E F
X 0 1 2 3 4 5 6 7 X 0 1 2 3 4 5 6 7
CON A B C D X 8 9 A B C D E F CON A B C D X 8 9 A B C D E F
POINT
• Do not attach the mounting brackets in any ways other than those described
above.
ON
PW L RUN L ERR.
B RATE STATION NO.
1 2 4 1 2 4 8 1020 40
AJ65VBTS2-16T
0 1 2 3 4 5 6 7
8 9 A B C D E F
NC Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 YA YB YC YD YE YF
COM+ COM+
COM- NC
CON A B C D
7 - 33 7 - 33
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
7.10.1 Specifications
The following table shows the specifications of the DIN rail adapter.
Model
A6DIN1C
Item
Mountable module AJ65DBTB1-32D, AJ65DBTB1-32T1,
AJ65DBTB1-32R, AJ65DBTB1-32DT1,
AJ65DBTB1-32DR
External dimensions 174mm (6.85 inches) 68mm (2.68 inches)
10mm (0.39 inches)
Weight 0.05kg
Applicable DIN rail type (conforms to IEC TH35-7.5Fe, TH35-7.5Al, TH35-15Fe
60715)
(1) The DIN rail adapter is made from resin. Do not drop or apply strong
shock to the adapter.
Use two M4 screws (length: 10mm (0.39 inches)) to attach the DIN rail adapter to the
AJ65DBTB1-32 type compact remote I/O module.
The tightening torque range is 0.78 to 1.18N•m.
7 - 34 7 - 34
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
This section describes how to mount/remove the module to/from a DIN rail.
(c) When multiple DIN rail adapters are installed on the DIN rail, even though
the gaps among DIN rail adapters are filled, the spaces of 4mm (0.16 inches)
are left among the modules.
Unit: mm (inch)
7 - 35 7 - 35
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
7 - 36 7 - 36
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
64(2.52)
(0.33 9 = 3.01)
8.5 9 = 76.5
125(4.92)
76.5(3.01)
17.6(0.69)
13.35(0.53)
8(0.31)
4(0.16) 4.5(0.18)
44(1.73)
54(2.13)
3(0.12)
2.5(0.10)
2(0.08)
32.5(1.28)
13(0.51)
3.5(0.14)
21(0.83)
32(1.26)
7 - 37 7 - 37
7 HANDLING OF COMPACT REMOTE I/O MODULES
MELSEC-A
7 - 38 7 - 38
8 TROUBLESHOOTING
MELSEC-A
8 TROUBLESHOOTING
The following table lists causes and corrective actions for errors indicated by LEDs on
the compact remote I/O module when the SW, M/S and PRM LEDs are all off (i.e. the
master module is set properly) in the system configuration example shown below.
Power supply
CPU Master
module
LED status
Master Remote I/O module Cause Corrective action
module A B C
PW PW PW
L RUN L RUN L RUN Normal —
L ERR. L ERR. L ERR.
PW PW PW Since the LEDs on the compact remote Check the voltage of the 24V power supply, and
L RUN L RUN L RUN I/O module A are all off, the 24V power supply the proper power to the compact remote
L ERR. L ERR. L ERR. is not supplied or voltage is low. I/O module.
PW PW PW The compact remote I/O module A is Exchange the compact remote I/O module.
L RUN L RUN L RUN malfunctioning and the LEDs are
L ERR. L ERR. L ERR. unstable (all lights are off, in many
cases).
PW PW PW The L RUN lights on the compact Identify the disconnected point by referring to
TIME
L RUN L RUN L RUN remote I/O module B and beyond are the LED status, and correct it.
LINE
L ERR. L ERR. L ERR. off, indicating the transmission cable
or
between the compact remote I/O
TIME
module A and B has been disconnected
LINE
or removed from the terminal block.
8 PW PW PW The transmission cable is shorted. Find the shorted cable among the three
L RUN L RUN L RUN transmission cables and repair it.
L ERR. L ERR. L ERR.
PW PW PW The transmission cable is wired Verify wiring in the terminal box of the compact
L RUN L RUN L RUN incorrectly. remote I/O module and correct.
L ERR. L ERR. L ERR.
PW PW PW The L RUN lights on the compact Restart the power supply after the overlapped
L RUN L RUN L RUN remote I/O modules A and C are off, station numbers for the compact remote I/O
L ERR. L ERR. L ERR. indicating the station numbers for A and modules are corrected.
C are overlapping.
: lit, : unlit, : flashing, : lit, flashing or unlit
8-1 8-1
8 TROUBLESHOOTING
MELSEC-A
LED status
Master Remote I/O module Cause Corrective action
module A B C
PW PW PW The L RUN light on the compact remote Restart the power supply after the transmission
L RUN L RUN L RUN I/O module B is off, indicating the speed is set correctly.
L ERR. L ERR. L ERR. transmission speed setting for module B
is invalid within the setting range (0 to 4).
PW PW PW The L ERR. of the compact remote I/O Return the setting switch of the compact remote
TIME L RUN L RUN L RUN module C is flashing at fixed intervals, I/O module to the original position.
LINE L ERR. L ERR. L ERR. indicating the setting switch for module
or C has been changed during normal
TIME operation.
LINE PW PW PW The L RUN of the compact remote I/O Correct the setting switch of the compact remote
L RUN L RUN L RUN module A is off and L ERR. of the same I/O module, and restart the power supply.
L ERR. L ERR. L ERR. module is lit, indicating the setting
switch for module A is set out of range
(transmission speed: 5 to 9, station
number: 65 or greater).
PW PW PW The L ERR. of the compact remote I/O Correctly perform grounding of the FGs for the
L RUN L RUN L RUN module B is lit, indicating that module B master module and all compact remote I/O
L ERR. L ERR. L ERR. is being affected by noise. (L RUN may modules.
be off.)
TIME
PW PW PW The L ERR. lights on the compact Verify the grounding of the SLD of the
LINE
L RUN L RUN L RUN remote I/O module B and beyond are lit, transmission cable.
or
L ERR. L ERR. L ERR. indicating the transmission cable is Separate the wire from the power cable as
TIME
affected by noise in the area between much as possible (100mm (3.94 inches) or
LINE
modules A and B. (L RUN may be off.) more).
PW PW PW A terminal resistor is not attached. Check if a terminal resistor is attached.
L RUN L RUN L RUN (L RUN may be off.)
L ERR. L ERR. L ERR.
: lit, : unlit, : flashing, : lit, flashing or unlit
8-2 8-2
8 TROUBLESHOOTING
MELSEC-A
Resistor Input
module
E1 E2 Input
module
E1 > E2
Example 3 Input signals do not turn off. • Input switch leakage current (driving with a • Connect the appropriate resistor so that the
contactless switch). terminal-to-terminal voltage of the input
module is below the OFF voltage value.
AC input AC input
Power supply
Example 5 Input signals do not turn off. • Leakage current due to line capacity of the • Same as Example 3.
wiring cable. • However, this problem will not occur if the
The line capacity "C" of a twisted pair wire is power supply as shown below is provided
about C=100PF/m. at the input device side.
AC input AC input
8-3 8-3
8 TROUBLESHOOTING
MELSEC-A
24VDC
(1) 1.7mA or less OFF current of the AJ65SBTB1-16D is not satisfied. Hence, connect a
resistor as shown below.
AJ65SBTB1-16D
3mA
Iz=1.7mA
R=1.3mA
Input impedance
R
3.3K
24VDC
Supposing that the resistance R is 3.9k , the power capacity W of resistor R is:
W = (Input voltage) 2 ÷ R = 26.42 ÷ 3900 = 0.179 (W)
(3) Connect a resistor of 3.9 (k ) and 1 to 2 (W) to a terminal which may cause an error,
since the power capacity of a resistor is selected so that it will be 3 to 5 times greater
than the actual power consumption.
1
3[mA] 5.36[V]
1 1
3.9[k ] 3.3[k ]
8-4 8-4
8 TROUBLESHOOTING
MELSEC-A
Examples of errors that may occur in the output circuit and the respective corrective
action are described below.
CC-Link compact-
type remote Countermeasure Digital display unit
output module (input signal section)
Dedicated
IC
24 V DC
power
supply
8-5 8-5
8 TROUBLESHOOTING
MELSEC-A
Resistor
[2]
Example 2 The load is not • Leakage current due to built-in surge • Connect a resistor to both ends of the
turned OFF. suppressor. load.
(Triac output) Caution is required when the wiring
distance from the output card to
CC-Link compact remote the load is long, since there may
triac output module be leakage current due to the line
Load
capacity.
Resistor
Leakage current
Load
Example 3 Time limit • Drive the relay first, and then drive the
changes when CR type timer at that contact.
the load is a CR
Caution is required as indicated in
type timer. Example 1 since the internal circuit
(Triac output) CC-Link compact remote may be half-wave rectified
triac output module CR depending on the timer.
timer
Resistor
Leakage current
CR timer
8-6 8-6
8 TROUBLESHOOTING
MELSEC-A
Control
circuit Load
Load
Triac
8-7 8-7
8 TROUBLESHOOTING
MELSEC-A
Install fast recovery diode. CC-Link system compact type remote I/O module
Yn
24VDC 24VDC
COM Constant-
voltage circuit
COM
8-8 8-8
8 TROUBLESHOOTING
MELSEC-A
Sink output
Y0
Load
turns on by 100 s
Load
R1
CTL-
SW: External power SW
supply (24V) at On C1
COM+
10ms or less
24V
(Example)
R1=40 , C1=300 F
Use the below expression to calculated a time constant
C1 R1=300 10-6 40
=12 10-3s
=12ms
8-9 8-9
8 TROUBLESHOOTING
MELSEC-A
[1]
Sink output
COM+
Shut off [3]
Back electromotive
CTL- force
Load
Output module,
ombined module
Sink output Back electromotive [3]
force
Load
(2) Install a diode between the positive and negative external
Y0
ON power supply to allow an electric current to pass another
current path.
[2]
Load When the corrective action shown in the example 1 is
Y1
OFF taken simultaneously, the diode must be installed in
parallel with the C1 and R1.
[1]
Source output Back electromotive [3]
Shut off force
COM- Load
Y0
ON
CTL+
[2]
Load
Y1
OFF
[1]
Shut off
COM+
D1
C1 R1
CTL-
Example 1
[2]
Load
Y1
OFF
[1]
Shut off
COM-
D1
C1 R1
CTL+
Example 1
8 - 10 8 - 10
8 TROUBLESHOOTING
MELSEC-A
Output element
protection diode
8 - 11 8 - 11
APPENDICES
MELSEC-A
APPENDICES
Appendix 1 External Dimensions
Appendix 1.1 AJ65SBTB1-8 remote I/O module
The external dimensions for the AJ65SBTB1-8 remote I/O module are shown below.
(1.57)
40
87.3 (3.44)
+1 +0.04
78.3 0 (3.1 0 ) (Mounting pitch)
2-4.5 5.1 mounting holes (M4 screw)
40 20 10 8 4 2 1 4 2 1
16.5
ON
(A
A J65SBTB1-8D
(0.3)
pp
7.5
DA DG +24V 24G X0 X2 X4 X6 COM
ro
(1.97)
7.9
)
(0.31)
(0.16)
4
(0.08)
11
(When the protective cover attached.) (0.43)
2
ON
A J65SBTB1-8D
DA DG +24V 24G X0 X2 X4 X6 COM
DB SLD (FG) X1 X3 X5 X7 COM
(2.44)
62
(1.36)
34.5
PULL
A6CVR-8
87.3 (3.44) A
4 38.5 (1.52)
59 (2.32)
(0.16) 52.5 (2.07)
30.5 (1.20)
Unit: mm (inch)
App - 1 App - 1
APPENDICES
MELSEC-A
The external dimensions for the AJ65SBTB1-16 remote I/O module are shown
below.
(1.57)
40
118 (4.65)
109 +10 (4.29+0.04
0 ) (Mounting pitch)
2-4.5 5.1 mounting holes (M4 screw)
40 20 10 8 4 2 1 4 2 1
16.5
ON
AJ65SBTB1-16D (A
(0.3)
DA DG +24V 24G X0 X2 X4 X6 X8 XA XC XE COM
7.5
pp
(1.97)
x.
10 DIN rail
5 center
) 7.9
(0.31)
(0.16)
2 (0.08)
4
11
(When the protective cover attached.) (0.43)
ON
AJ65SBTB1-16D
DA DG +24V 24G X0 X2 X4 X6 X8 XA XC XE COM
DB SLD (FG) X1 X3 X5 X7 X9 XB XD XF COM
(2.44)
62
(1.36)
34.5
PULL
A6CVR-16
52.5
46 (1.81)
(2.07)
Unit: mm (inch)
App - 2 App - 2
APPENDICES
MELSEC-A
Remark
For AJ65SBTB1-16D, AJ65SBTB1-16T Remote I/O Module of hardware version D
or before, side face diagram of the module is as follows.
20
(0.79)
(0.43)
11
(A
pp
ro
(0.3)
x.
7.5
11
0)
DIN rail center
7.9
(0.31)
App - 3 App - 3
APPENDICES
MELSEC-A
The external dimensions for the AJ65SBTW4-16 remote I/O module are shown
below.
184.7 (7.27)
180 +10 (7.09 +0.04 ) (Mounting pitch)
2.1 0 2.6
(0.08) (0.10)
2-4.5 5.1 mounting holes (M4 screw)
(2.36)
60
(1.18)
30
(0.47)
12
(1.00)
25.5
X2 YA
X3 YB
CON1 CON3 CON5 CON7 X4 YC
LINK CABL OUT POWER CABL X5 YD
CON2 CON4 CON6 CON8
X6 YE
X7 YF
STATION NO.
MITSUBISHI AJ65SBTW4-16DT
Unit : mm (inch)
App - 4 App - 4
APPENDICES
MELSEC-A
The external dimensions for the AJ65SBTB1-32 remote I/O module are shown
below.
(1.57)
40
179 (7.05)
+1 +0.04
170 0 (6.7 0 ) (Mounting pitch)
2-4.5 5.1 mounting holes (M4 screw)
(0.65)
40 20 10 8 4 2 1 4 2 1
ON
(A
AJ65SBTB1-32D
(0.3)
pp
7.5
DA DG +24V 24G X0 X2 X4 X6 X8 XA XC XE X10 X12 X14 X16 X18 X1A X1C X1E COM
50
ro
DB SLD (FG) X1 X3 X5 X7 X9 XB XD XF X11 X13 X15 X17 X19 X1B X1D X1F COM
x.
DIN rail
10
7.9 center
5
)
(0.31)
(0.16)
89 (3.5)
4
2 (0.08)
ON
AJ65SBTB1-32D
DA DG +24V 24G X0 X2 X4 X6 X8 XA XC XE X10 X12 X14 X16 X18 X1A X1C X1E COM
DB SLD (FG) X1 X3 X5 X7 X9 XB XD XF X11 X13 X15 X17 X19 X1B X1D X1F COM
(2.44)
62
34.5 (1.36)
PULL
A6CVR-32
4 38.5 (1.52)
179 (7.05) (0.16) 52.5 (2.07)
151 (5.94)
76.5 (3.01)
Unit: mm (inch)
App - 5 App - 5
APPENDICES
MELSEC-A
Remark
For AJ65SBTB1-32D, AJ65SBTB1-32T Remote I/O Module of hardware version D
or before, side face diagram of the module is as follows.
20
(0.79)
(0.43)
11
(A
p
pr
ox
(0.3)
7.5
.1
10
DIN rail center
)
7.9
(0.31)
App - 6 App - 6
APPENDICES
MELSEC-A
The external dimensions for the AJ65SBTC1-32 , and AJ65SBTC4-16 remote I/O
modules are shown below.
(1.57)
40
118 (4.65)
+1 +0.04
109 0 (4.29 0 ) (Mounting pitch)
2-4.5 5.1 mounting holes (M4 screw)
X0 1 2 3 4 5 6 7 X8 9 A B C D E F
16.5
40 20 10 8 4 2 1 4 2 1 ON
A J65SBTC4-16DN
(A
pp
(0.3)
7.5
(1.97)
2 (0.08)
11
(When the protective cover attached.)
(0.43)
STATION NO. B RATE
X0 1 2 3 4 5 6 7 X8 9 A B C D E F
40 20 10 8 4 2 1 4 2 1 ON
A J65SBTC4-16DN
DA DG +24V 24G X0 X1 X2 X3 X4 X5 X6 X7 COM
DB SLD (FG) Y8 Y9 YA YB YC YD YE YF COM
+24V +24V +24V +24V +24V +24V +24V +24V
(2.44)
(1.36)
34.5
PULL
A6CVR-16
Unit: mm (inch)
App - 7 App - 7
APPENDICES
MELSEC-A
Remark
(1) For the AJ65SBTC4-16D remote I/O module, the side view of the module is
shown below.
20
(0.79)
(0.43)
11
(A
pp
ro
x.
(0.3)
7.5
11
0
)
(2) For the modules given in the following table, the side view is shown below.
20
(0.79)
(0.43)
11
(A
pp
ro
x.
(0.30)
11
7.5
0 )
App - 8 App - 8
APPENDICES
MELSEC-A
The external dimensions for the AJ65SBTCF1-32 remote I/O module are shown
below.
(1.57)
40
118 (4.64)
+1 +0.04
109 0 (4.29 0 ) (Mounting pitch)
2-4.5 5.1 mounting holes (M4 screw)
(0.65)
X0-XF ON
(A
X10 11121314151617 X18191A1B1C1D1E1F
pp
A J65SBTCF1-32D X10-X1F
(0.3)
7.5
ro
DA DG 24V 24G X10 X11 X12 X13 X14 X15 X16 X17 X18 X19 X1A X1B X1C X1D X1E X1F NC NC NC NC
x.
(1.57)
10
7.9
14 (0.55)
(0.31)
or less
(0.16)
46 (1.81)
4
Unit : mm (inch)
Remark
For the modules given in the following table, the side view is shown below.
20
(0.79)
(0.43)
11
(A
p pr
ox
.1
(0.30)
7.5
10
)
App - 9 App - 9
APPENDICES
MELSEC-A
118 (4.65)
+1 +0.04
109 0 (4.29 0 ) (Mounting pitch)
Y0 1 2 3 4 5 6 7 40 20 10 8 4 2 1 4 2 1
16.5
ON
AJ65SBTB2-8T
(0.3)
(A
7.5
DA DG +24V 24G Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 DC24V
50 (1.97)
pp
DB SLD (FG) COM COM COM COM COM COM COM COM DC24G
ro
x.
DIN rail
10
7.9
5
)
(0.31)
4 (0.16)
2 (0.08)
11
(When the protective cover attached.) (0.43)
STATION NO. B RATE
Y0 1 2 3 4 5 6 7 40 20 10 8 4 2 1 4 2 1
ON
AJ65SBTB2-8T
DA DG +24V 24G Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 DC24V
DB SLD (FG) COM COM COM COM COM COM COM COM DC24G
(2.44)
62
(1.36)
34.5
PULL
A6CVR-16
Unit: mm (inch)
App - 10 App - 10
APPENDICES
MELSEC-A
179 (7.05)
+1 +0.04
107 0 (4.2 0 ) (Mounting pitch)
2-4.5 5.1 mounting holes (M4 screw)
PW L RUN L ERR. Y0 1 2 3 4 5 6 7 Y8 9 A B C D E F STATION NO. B RATE
40 20 10 8 4 2 1 4 2 1
(0.65)
16.5
ON
(A
AJ65SBTB2-16T
(0.3)
p
7.5
DA DG +24V 24G Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 YA YB YC YD YE YF
pr
DC24V
(1.97)
DB SLD (FG) COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM
ox
DC24G
50
.1
05
7.9
)
(0.31)
4 (0.16)
2 (0.08)
89 (3.5)
(When the protective cover attached.) 11
(0.43)
PW L RUN L ERR. Y0 1 2 3 4 5 6 7 Y8 9 A B C D E F STATION NO. B RATE
40 20 10 8 4 2 1 4 2 1
ON
AJ65SBTB2-16T
DA DG +24V 24G Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 YA YB YC YD YE YF DC24V
(2.44)
DB SLD (FG) COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM DC24G
62
(1.36)
34.5
PULL
A6CVR-32
4 38.5 (1.52)
179 (7.05) (0.16)
52.5 (2.07)
151 (5.94)
76.5 (3.01)
Unit: mm (inch)
App - 11 App - 11
APPENDICES
MELSEC-A
The external dimensions for the AJ65SBTB2N-8 remote I/O module are shown
below.
(1.57)
40
118 (4.65)
+1 +0.04
109 0 (4.29 0 ) (Mounting pitch)
40 20 10 8 4 2 1 4 2 1
AJ65SBTB2N-8A
16.5
ON
(A
(0.3)
7.5
DA DG +24V 24G X0 X1 X2 X3 X4 X5 X6 X7 COMA
pp
50 (1.97)
DB SLD (FG) COMB COMB COMB COMB COMB COMB COMB COMB COMB
ro
x.
7.9
)
(0.31)
4 (0.16)
2 (0.08)
11
(When the protective cover attached.) (0.43)
DA DG +24V 24G
X0 X1 X2 X3 X4 X5 X6 X7 COM A
DB SLD (FG)
(2.44)
(1.36)
34.5
PULL
A6CVR-16
Unit: mm (inch)
App - 12 App - 12
APPENDICES
MELSEC-A
The external dimensions for the AJ65SBTB2N-16 remote I/O module are shown
below.
(1.57)
40
179 (7.05)
+1 +0.04
107 0 (4.2 0 ) (Mounting pitch)
2-4.5 5.1 mounting holes (M4 screw)
STATION NO. B RATE PW L RUN L ERR. X0 1 2 3 4 5 6 7 X8 9 A B C D E F
40 20 10 8 4 2 1 4 2 1
(0.65)
AJ65SBTB2N-16A
(1.97) 16.5
ON
(0.3)
7.5
DA DG +24V 24G X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF COMA
(A
DB SLD (FG) COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB
pp
50
ro
x.
7.9
10
(0.31)
5
)
4 (0.16)
89 (3.5) 2 (0.08)
11
(When the protective cover attached.) (0.43)
STATION NO. B RATE PW L RUN L ERR. X0 1 2 3 4 5 6 7 X8 9 A B C D E F
40 20 10 8 4 2 1 4 2 1
AJ65SBTB2N-16A
ON
(1.36)
34.5
PULL
A6CVR-32
4 38.5 (1.52)
179 (7.05) (0.16)
52.5 (2.07)
151 (5.94)
76.5 (3.01)
Unit: mm (inch)
App - 13 App - 13
APPENDICES
MELSEC-A
AJ65VBTCU -8
40S
20T
A
10T
8 I
4 O
N
2N
1 O
4 B
B
2 A
T
1 E
AJ65VBTCU3-8D1
CON L
A I
N
CON K
B 57.5(2.26)
X0 PW
L RUN
X1
L ERR
X2
0
115(4.53)
1 DIN
X3 2 rail
3
4
X4 5
6
X5 7
X6
57.5(2.26)
X7
P
CON W
C /
A
U
CON X
D
Unit: mm (inch)
: This section should be 14.5mm (0.57 inches) when an online connector is not installed.
App - 14 App - 14
APPENDICES
MELSEC-A
AJ65VBTCU -16
40 S
20 T
A
10 T
8 I
4 O
N
2 N
1 O
4 B
B
2 A
T
1 E
AJ65VBTCU3-16D1
CON L
A I
N
CON K
B
57.5(2.26)
PW
L RUN
L ERR
0
1 DIN
2
115(4.53)
rail
3
4
5
6
7
8
9
A
B
C
57.5(2.26)
D
E
X0 to X7 X8 to XF F
CON P
C W
/
A
CON U
D X
Unit: mm (inch)
: This section should be 14.5mm (0.57 inches) when an online connector is not installed.
App - 15 App - 15
APPENDICES
MELSEC-A
AJ65VBTCF 1-32
57.5(2.27)
DIN
115 (4.53)
rail
57.5(2.27)
16.5
(0.65)
2(0.08)
31(1.22) 67(2.64)
Unit: mm (inch)
: This section should be 14.5mm (0.57 inches) when an online connector is not installed.
App - 16 App - 16
APPENDICES
MELSEC-A
The external dimensions for the AJ65FBTA -16 remote I/O modules are shown
below.
AJ65FBTA -16
2-4.5 6 mounting screw
+1 +0.04
60 0 2.36 0
48(1.89)
50 1 (1.97 0.04)
34 0.5
(0.17)
26.5
4.3
18.3 (1.34 0.02)
(0.72) (1.04) 6(0.24)
(0.84)
21.3
68(2.68)
+0.04
24(0.94)
33(1.30)
25(0.98)
25(0.98)
25(0.98)
Storage sheet
6(0.24)
4.1 21.7
(0.16) 35 M4 mounting screw (0.85)
32
(1.38) (1.26)
Unit: mm (inch)
App - 17 App - 17
APPENDICES
MELSEC-A
Appendix 1.13 AJ65VBTS -16 , and AJ65VBTS -32 remote I/O module
The external dimensions of the AJ65VBTS -16 , and AJ65VBTS -32 remote I/O
modules are shown below.
AJ65VBTS -16
2-M4 mounting holes
137 (5.39)
15.5
(0.53)
13.5
106 0.5 (4.17 0.02) (0.61) 5.0
(0.47)
(0.20)
12
ONPW
B RATE STATION NO.
L RUN L ERR.
(0.91)
1 2 4 1 2 4 8 1020 40
AJ65VBTS3-16D
(1.02 0.01)
0 1 2 3 4 5 6 7
23
(2.52 0.01)
8 9 A B C D E F
26 0.3
64 0.3
NC X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF
(1.97)
50
(1.65)
DIN rail center
42
COM+ COM+
4
COM- COM-
(0.16)
CON A B C D
(0.18)
4.5 51.5
(0.53)
13.5
(2.03)
(1.22)
31
(0.65)
16.5
(1.24)
31.5
(0.20)
5
13.5 13.5
151 0.5 (5.94 0.02)
(0.53) (0.53)
Unit: mm (inch)
: This section should be 145mm (0.57 inches) when an online connector is not installed.
App - 18 App - 18
APPENDICES
MELSEC-A
AJ65VBTS -32
13.5 222 13.5 2-M4 mounting holes
(0.53) (8.74) (0.53)
PW L RUN
L ERR.
(0.91)
1 2 4 1 2 4 8 102040
AJ65VBTS3-32D
0 1 2 3 4 5 6 7
23
50 (1.97)
8 9 A B CD E F
26 0.3
NC X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF NC X10 X11 X12 X13 X14 X15 X16 X17 X18 X19 X1A X1B X1C X1D X1E X1F
(1.65)
42
DIN rail center
COM1+ COM1+ COM2+ COM2+
CON A B C D
4
236 0.5 51.5 (0.16)
(9.29 0.02) (2.03)
(1.22)
31
(0.65)
16.5
(1.24)
31.5
(0.20)
5
Unit: mm (inch)
: This section should be 14.5mm (0.57 inches) when an online connector is not installed.
App - 19 App - 19
APPENDICES
MELSEC-A
Appendix 1.14 AJ65VBTCE -8 , AJ65VBTCE -16 , and AJ65VBTCE -32 remote I/O
module
AJ65VBTCE -8
54 0.3
(2.13 0.01)
40.5 (1.59)
13.5 13.5
(0.53) (0.53)
31 30.5
(1.22) (1.20)
(0.53)
13.5
40 16.5 26
(1.57) (0.65) (1.02)
CON ON
1
2
A 3
4
5
6
7
(1.63)
8
9
41.5
B 10
40 S
T
20 A
C 10 T
I
8 O
4 N
2 N
1 O.
(3.27 0.02)
D 4 B
(4.49 0.02)
R
2 A
T
1
114 0.5
E
83 0.5
AJ65VBTCE3-8D
PW
X0 L RUN
(3.94)
100
L ERR.
X1
0
1
X2 2
3
X3 4
5
6
X4 7
X5
X6
DIN rail center
X7
(0.16)
4
(0.53)
13.5
Unit: mm (inch)
: This section should be 14.5mm (0.57 inches) when an online connector is not installed.
App - 20 App - 20
APPENDICES
MELSEC-A
AJ65VBTCE -8
(When the protective cover attached.)
29
(1.14)
(2.03)
51.5
(0.81)
20.5
89 (3.50)
CON ON
B
40 S
T
20 A
10 T
I
C 8 O
4 N
2 N
1 O.
.
4 B
R
D 2 A
T
1 E
AJ65VBTCE3- 8D
PW
(4.07)
103.5
X0 L RUN
L ERR.
X1
0
1
X2 2
3
X3 4
5
6
X4 7
X5
X6
>PC<
X7
40.5
43.5 (1.71) (1.59)
(1.52)
38.5
29
(1.14)
Unit: mm (inch)
App - 21 App - 21
APPENDICES
MELSEC-A
AJ65VBTCE -16
100 2-M4 mounting holes
(3.94) 8.5 5.0
(0.53)
13.5
(0.33) (0.20)
83 0.5
(0.33)
(3.27 0.02)
8.5
ON
PW L RUNL ERR. AJ65VBTCE3-16D
1 2 4 1 2 4 8 102040
B RATE STATION NO.
(0.93)
23.5
0 1 2 3 4 5 6 7
(1.30 0.01)
(2.52 0.01)
8 9 A B C D E F
33 0.3
64 0.3
(1.97)
50
X 0 1 2 3 4 5 6 7
DIN rail center
4
(0.16)
CON A B C D X 8 9 A B C D E F
(0.18)
4.5
(0.16) 41.5
(0.53)
13.5
(1.63)
DIN rail center 45.5
(1.22)
(1.79)
31
(0.65)
16.5
(1.24)
31.5
(0.20)
5
Unit: mm (inch)
: This section should be 14.5mm (0.57 inches) when an online connector is not installed.
App - 22 App - 22
APPENDICES
MELSEC-A
AJ65VBTCE -16
(When the protective cover attached.)
29
(1.14)
(2.03)
51.5
(0.81)
20.5
90
(3.54)
CON A
1 2 4 1 2 4 8 102040
B RATESTATION NO.
ON
B
0 1 2 3 4 5 6 7
C
D
(4.09)
104
Y
X
8
0
9
1
A
2
3
B
AJ65VBTCE32-16DT
C
4
D
>PC<
6
E
7
F
41.5
54 (2.13) (1.63)
(1.48)
37.5
39
(1.54)
Unit: mm (inch)
App - 23 App - 23
APPENDICES
MELSEC-A
AJ65VBTCE -32
2-M4 mounting holes
(0.53)
13.5 155 (6.10) 13.5 5.0
13.5
(0.53) 129 0.5 (5.08 0.02) (0.53) (0.20)
(0.33)
8.5
AJ65VBTCE3-32D
(0.93)
(1.02 0.01)
23.5
(2.52 0.01)
26 0.3
(1.97)
64 0.3
50
4
(0.16)
(0.18)
4
4.5
41.5 (1.63) DIN rail center
(0.16)
(0.53)
13.5
169 0.5 45.5 (1.79)
(6.65 0.02)
(0.65)
16.5
(1.24)
(0.20)
31.5
72.5
(2.85)
Unit: mm (inch)
: This section should be 14.5mm (0.57 inches) when an online connector is not installed.
App - 24 App - 24
APPENDICES
MELSEC-A
The external dimensions of the AJ65DBTB1-32 remote I/O modules are shown
below.
Unit: mm (inch)
App - 25 App - 25
APPENDICES
MELSEC-A
(1.57)
40
179 (7.05)
170 (6.70 ) (Mounting pitch)
2-4.5 5.1 mounting holes (M4 screw)
7.9
(0.31)
(0.65)
16.5
(A
pp
ro
(1.97)
x.
50
10
(0.3)
5
7.5
)
(0.16)
89 (3.50)
Unit: mm (inch)
App - 26 App - 26
APPENDICES
MELSEC-A
MEMO
App - 27 App - 27
WARRANTY
Please confirm the following product warranty details before using this product.
3. Overseas service
Overseas, repairs shall be accepted by Mitsubishi's local overseas FA Center. Note that the repair conditions at each FA
Center may differ.
SH(NA)-4007-AA